Loading...
HomeMy WebLinkAbout50188-Z �o�oS�IFf� cpGy Town of Southold 2/2/2024 a P.O.Box 1179 o53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44917 Date: 2/2/2024 THIS CERTIFIES that the building 14VAC Location of Property: 485 Sutton Pl, Greenport SCTM#: 473889 Sec/Block/Lot: 33.-5-6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/6/2023 pursuant to which Building Permit No. 50188 dated 1/8/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"HVAC system as applied for. The certificate is issued to Karadimas,Christos of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50188 01/19/2024 PLUMBERS CERTIFICATION DATED th rized ature o�SOF �co. TOWN OF SOUTHOLD ay BUILDING DEPARTMENT a ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50188 Date: 1/8/2024 Permission is hereby granted to: Karadimas, Christos 428 E 142nd St Bronx, NY 10454 To: legalize "as built" HVAC system as applied for. At premises located at: 485 Sutton PI, Greenport SCTM #473889 Sec/Block/Lot# 33.-5-6 Pursuant to application dated 12/6/2023 and approved by the Building Inspector. To expire on 719/2025. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $500.00 ELECTRIC $200.00 CO-ALTERATION TO DWELLING $100.00 Total: $800.00 B g Inspector *pF SOUjyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q cCD •���� sear.devlintown.southold.ny.us Southold,NY11971-0959 COUNTY BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Christos Karadimas Address: 485 Sutton PI city:Greenport st: NY zip: 11944 Building Permit#: 50188 Section: 33 Block: 5 Lot: 6 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC-CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Residential X Basement Service Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 7 Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect 2 Switches 4'LED Exit Fixtures Sump Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " HVAC Inspector Signature: Date: January 19, 2024 S.Devlin-Cert Electrical Compliance Form OF SOGIy�� * # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: f uMk 1(��✓ Vt DATE O INSPECTOR pF SOUtyO� # # TOWN .OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: A-E - ---- ----- - -- - - - - - --- -- DATE / ' INSPECTO `� ho��0FS0UTh°lam ✓ P # T11 OF SOUTHOLD BUILDING DEPT. loum, 631-765-1802 5oi6 - INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I LATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL P-C, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE tin bg)ey INSPECTOR i FIELD INSPECTION REPORT7 DATE COMMENTS �ro G� FOUNDATION (1ST) ol�v -------------------------------------- FOUNDATION (2ND) .cn z � O ROUGH FRAMING& t� PLUMBING -tea I . i INSULATION PER N.Y. STATE ENERGY CODE 40F i, FINAL o: i ADDITIONAL COMMENTS Z� m i N o a x d � ro TOWN.OF SOUTHOLD—BUILDING DEPARTMENT C* C� Town Hall Annex 5437,5 Main Road P. O. Box 1179 Southold,NY 11971-0959 w- Telephone(631) 765-1802 Fax(631) 765-9502 hqs://www.southoldtpwnn . off;& F7 7e\/,7f—;:z) .Date' Received \-j DEC 6 2023 APPLICATION FOR BUILDING PERMIT or Office Use Only a PERMIT NO. Building[Inspector: A- on Will nbt,be aceept00,�`Wll gAl AutF `riz 9 P r6 Date: RO PE p Name: SCTM#1000- Project Address: Phone#: f�?fl Email:9��Fzk Mailing Address: &V T _PfRS -1, ON: 1 Name: MID P-4 S Mailing Address: F,/Qc,�2 Phone#: /Email: DE G f ION ll 5N OkMALT�kl!NF Name: Mailing Address: Phone#: II Email: N-Ill TIO Name: "mcAcra-, kw- V\ acd Av- &),rNdMc nc Mailing Address: c) x\1 �A (Z Phone#: Enl (? ..........C 11 IF R ❑NewStructure ElAddition MAlteratiolln EIRepair nDemolition Estimated Cost of Project: )Q.Other r-s-Z V\ $ 255% �cpc--) Will the lot be re-graded? ElYes KNO 11,1 Will excess fill be removed from premises? DYes KNO III PROPERTY!,,FORMAT M f: Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑,Che y. ek Bax After'Reading The owner/contractor/design professional is responsible'forall drainage and storrit water issues at,pr. ovided by_: chapter 236 of the Town code. ApPLICAt10N IS:HEREBY MADE.to:fhe Budding`Department for.the issuance.of a euiltlmg Permit pursuant to the Building Zone Ord'iriance;of the Towri of souttiold,,Suffolk,:County,,Ne,'w York and othei.applirabte i aws,Ordinances or Regulations;fo�.the construction of.buil "' ;_'•''dings. . additions,alterations or for;remov`al.or demolition as herein described The applicant agrees#o comply with,altepplicable,laws,o dinences,•building codB,': ,; hopsing code and`regulations and;to admit authorized inspectors on remises and In building(s),for necesseryinspections False statements m"ade herein are punisFia6le as a Class'A misdemeanor pursuant to,Sect�on;210.45:of the New.York State Penal law: Application Submitted By(print name ❑Authorized Agent OOwner Signature of Applicant: ;,II Date: 22023 CONNIE D.BUNCH Notary Public,State of New York STATE OF NEW YORK) No. 01 BU6185050 SS: Qualified in Suffolk County Co Commission Expires April 14, 2 `{ COUNTY OF ) I (Name of individual signing contract)above named, being duly sworn, deposes and says that(s)he is the applicant I (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and, that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ��X I 20 w 7 n L ��?/(/1 c Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) 1, residing at do hereby authorize to•apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 III �ffOL j BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD ® Town Hall Annex-54375 Main Road -PO Box 1179 v ! Southold, New York 11971-0959 ®� Telephone (631) 765-1802- FAX(631) 765-9502 jamesh(&-southoldtownn ..aov- seand(&southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: _ Elec.email: Elec. Phone No: c' ; - Cj I request hn email copy of Certificat of Compliance Elec. Address.: \ _ JOB SITE INFORMATION (All Information Required) Name: Address: Cross Street: Phone No.: Bldg.Permit#: Q ( email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Pleas Pri t Clearly): Ir�sto�lle� 2. lbcsszm�n�� csr c 14�/ Y AC Square Footage: Circle All That Apply: Is job ready for inspection?: YES❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES❑NO Issued On Temp Information: j (All information required) Service Size❑1 Ph i 3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals Ell FJ2 n H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road -PO Box 1179 co Southold, New York 11971-0959 ®rr Telephone (631) 765-1802- FAX (631) 765-9502 la mesh(a�southoldtownny gov- seand(a)southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name, ? C C Electrician's Name: License No.: M_ - Elec.email: f=,C1p e� Elec. Phone No: � - 0j I request an email copy of Certificqt of Compliance Elec. Address.: \ JOB SITE INFORMATION (All Information Required) Name: Address: ' Cross Street: Phone No.: BIdg.Permit#: 0 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Pleas Pri t Clearly): �bcs�mex�-�� �csr y � Square Footage: Circle All That Apply: Is job ready for inspection?: YES❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES❑NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect[]service Reconnect❑Underground❑Overhead #Underground Laterals 1 2 H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION ��n� I i :�s4""'Tsa. ?c��-,q,.r�r•«'a- ;.. `' t, e`;.�^es'��. ...4�e�..' _ 'ti`s�, rr,q; ':r $ 64f` »-"', x-" °'`°`�•yy� 4 '.f.'r� '.a«'' n..*s` '+ ,4Y„w�� °`rey4,,�,,�. / „✓�„,wr..,....ra - , =�^,;', M16"K,, F `' •, "'V; -W" ir4':. "W' !- r �.>. / s• '�v^f i'.�7 « q--.7i, - i.r" `"fix:. :,i`-"� i.::t %1-`L - :a•�- T�a+ s�i+rawr.•v:.r, .nos,,.^:7 v«'. tt`, ;"'nrS'." <F .+�< ' i . .';;.:�x::x.._�mz�.,as�t' 'avrsi:�•'�>�a[�r���ama•.�.:bra.'�tn�c�.�a�x <:�zs�.am:�sr<'��'s:a':�;,�wz.�'�.�csr;,s�Tcai�c.*stiia.�'sec::e�:�;t'naa,�� ��a'c��i•,t;«s.,":r.;s�3s'zsas.nmcw ._�uu..-s:,.s_..ast.ia�.Y�',..e:4�a,.. �2�z'�.�^ •: - ..:s'F w of La ent 5u olk Count De rxrtm � bor, Licensing ; ° �: _ r .ar Consume airs er Aff , VETERANS MEMORIAL HIGHWAY * HAUPPAUGE,NEW YORK•11788 ' DATE ISSUED:' 12A/2016 No. , . 57769-H 5 d i SUFFOLK'COUNTY ' y� Horne Improvement Contractor License �. sass This is to certify,that JUNIOR MARTE '' " .. doing,business as. r ¢ Asa HATgPTONS AIR HEATING &AIR.CONDITIONING:,INC. having furnished the requirements set forth:n,accordance with.and subject to the provisions of_applicable laws,rules and regulations of the County of.Suffolk,;State of New York is hereby:licensed.to conduct business as a-HOME sop r Y i IMPROVEMENT CON TRACTOR, in the County of Suffolk. s t License Category ;' ` s <- Duct Work k%' NOT VALID WIT Ad HOUT ditional Businesses r - -DEPARTMEN'I"AL-SEAL AND A CURRENT a' CONSUMER.AFFAIRS 1D:CARD ;� . . Commissioner .;n,: >:r.:. v:; �•,„� �:�:GYSeSFfa,, a rod //— `^� -.%.,ngr+.�:,�u.a',s�.�S�3ac7�._,You'.4.:tL:SWia:.rr.�•7,a�+f,fli3�£v:',L•..•3a�r,4zv...aUSYu....t,:a�at•�a,:.2:;#dS'a: f. .Y Y � • t s '* � :•.✓''� � • �� E6•`° �*.1+'� \���+�a�^cF't!,Sy^' 3n,'?^.-...�,.,,..°TToC.y"'�v »5�...� '°a"'F.m.1' '�dere eaeg,« _.�<,aao ppci,;;•w _ '�°: a w�• - - a a< a'>e eA�^ ;•�.';s::a :sa�.',arr-' ,E.°+.6<e <:«kr'`< =a,,�r°: ,e�°..;�',:ti -y=.��.�,, 4�,ti hg:. •�� �,,• ..... .�;�err' �....-, �' ' IIn Jw I, Job Name: System Reference: j,ll Date: II ..r:;irlllllllllllllud:a• II �tr j'f.�ilIIIHIIIIIIIIIIHIIIIIIIIIIIi��,xt �l ��IIIIIIIIIIIIIIHIIIIIIIIIIIIIIIIIIHIiII� !II'I IIIIIIIIIIIIIIIIIIililllllllllllllllll!!I `tllllllllllllllllllllllllllllllllllfl!"' !'u t�''lll�llllllllllllll�il�'''� �'I� i ,tlalilllllHlllllllllnml,. �IIIIIIIIIIIIIIIIIIIIIIIIIIHIIIIIIIIIII , iIIIIIIIIIIIIHIIIIIIHIHIIIIIIIIIIIIHI��� �,�I, �IIIIIIIIIIIIIIIIHIIHIIIIIIIIIIIIIill I 'IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIRI'' ��� ' '��IIIIIIIHIIIIUpn° �II j III 71 FEATURES • Compatible with M-and P-Series and CITY MULTI®indoor units.Branch box required for connection with M-and P-Series • Variable speed INVERTER-driven compressor�1t • Seacoast protection on heat exchanger and base panel(rated for 2,000 hrs in accordance with ASTM B117 testing) • Thermal Differential 1°F(with PAC-MKA32/52B only) • Built-in base pan heater j III • Quiet outdoor unit operation,rated sound press'u re as low as 50 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Hyper-heating performance offers 100%•heati Ig capacity at 5°F and 75%heating capacity at-13°F APPROVED AS NOTED D 8•P COMPLY WITH ALL CODES OF FEE •t eY6 III A YORK STATE &TOWN CODES NOTIFYBUiLDING DEPARTMENT AT REQUIRED AND CONDITIONS OF 83171l802 8AM TO 4PM FOR THE ill VIUTIILD, WN ZBA (. FOLLOWING INSPECTIONS: I'I ,�___ WN PLANNING BOARD 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE j III =_ -sonWN TRUSTEES 2. ROUGH-FRAMING&PLUMBING I 3. INSULATION ill 4. FINAL-CONSTRUCTION MUST �II C OCCUPANCY OR BE COMPLETE FOR C.O. �'I ALL CONSTRUCTION SHALL MEET THE'IIII U S E IS UNLAWFUL REQUREMENS OFTHE CODES OF NEW, YORKI STATE.TNOT RESPONSIBLE F R' ELECTRICAL 1,,VITHOUT CERTIFICAT.. DESIGN OR CONSTRUCTON ERRORS j' INSPECTION REQUIRED DF OCCUPANCY ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US l All rights reserved. ll e sSM422RAMW Maximum Capacity BTU/H 42,0001/42,000/!42,000 Rated Capacity BTU/H 42.000//42,0001142,000 Cooling'(Non-Ducted//Mix//Ducted) Minimum Capacity BTU/H 16.500//15,500//15,500 Maximum Power Input W 3,135//3,440//3,820 Rated Power Input W 3,135//3,440 9 3,820 Power Factor(208V,230V) % 98.5,98.5/198.5.98.5//98.5,98.5 Maximum Capacity BTU/H 48,000//48.000//48,000 Rated Capacity BTU/H 48,000 H 46,000//48,000 Heating at 47°F'(Non-Ducted/1 Mix// Minimum Capacity BTU/H 24,000//24.000l124,000 Ducted) Maximum Power Input W 3,430113,750 U 4,140 Rated Power Input W 3,430//3,750 H 4,140 Power Factor(208V,230V) % 98.5.98.5//98.5.98.5//98.5,98.5 Maximum Capacity BTU/H 49,200//49,200 U 49,200 Heating at 17°F'(Non-Ducted//Mix/! Rated Capacity BTU/H 32,000/!32,000//32,000 Ducted) Maximum Power Input W 6,110//6,900//7,250 Rated Power Input W 3,350!/3,550!/3,750 Heating at 5°F"(Non-Ducted//Mix// Maximum Capacity BTU/H 48,000 H 48,000//48,000 Ducted) Maximum Power Input W 7.030//7,215//7,405 SEER 22.0//20.0//18.0 EER' 13.4//12.2//11.0 HSPF(IV) 12.0 1111.51/11.0 Efficiency(Non-Ducted//Mix//Ducted) COP at 47°F' 4.1 H 3.75//3.4 COP at 17°F at Maximum Capacity' 2.3//2.0//1.9 COP at 5°F at Maximum Capacity° 2.0//1.95//1.9 ENERGY STAR®Certified Yes//No//No Electrical Power Requirements Voltage,Phase, 208/230.1,60 Frequency Guaranteed Voltage Range VAC 187-253 Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) kA 5 Recommended Fuse/Breaker Size if Branch Box Powered by A 40(45) Outdoor Unit Electrical Recommended Fuse/Breaker Size without Branch Box or A 40 Branch Box Powered Separate Recommended Wire Size AWG 6 MCA if Branch Box Powered by Outdoor Unit A 42.0 MOCP if Branch Box Powered by Outdoor Unit A 50 MCA without Branch Box or Branch Box Powered Separate A 36 MOCP without Branch Box or Branch Box Powered Separate A 40 Fan Motor Full Load Amperage A 0.6+0.6 Airflow Rate(Cooling/Heating) CFM 3,885/3,885 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Heat Exchanger Coating Blue Fin Coaling Sound Pressure Level,Cooling' dB(A) 50 Sound Pressure Level„Heating' dB(A) 54 Compressor Type Hermetic Compressor Model ANB33FJSMT Compressor Motor Output kW 2.9 Outdoor unit Compressor Rated Load Amps A 19 Compressor Locked Rotor Amps A 22.0 Compressor Oil Type H Charge oz. FV50S 1/73 Base Pan Heater Built-in W.In.[mm] 41-11132(1,050] Unit Dimensions D:In.[mm] 13[330] H:In.[mm] 52-11/1611.338] W:In.[mm] 43[1,0901 Package Dimensions D:In.[mm] 18[4501 H:In.(mm] 57[1,430] Unit Weight I Lbs.[kg] 278[1261 Package Weight Lbs.[kg] 302[137] NOTES: AHRI Rated Conditions 'Cooling(Indoor/!Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47'F(Indoor//Outdoor) °F 70 DB,60 WB 1147 DB,43 WB 'Heating at 170F(Indoor//Outdoor) °F 70 DB,60 WB ll 17 DB,15 WB Conditions 'Hea[ing at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB 'Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. 'A when 1 or more PLA-A-EA7 connected "Branch box should be placed within the level between the outdoor unit and indoor units `5°F DB-115'F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. I i Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. D d Cooling Intake Air Teml(Maximum/Minimum') °FDB 115/23'c Outdoor unit operating temperature Cooling Thermal Lock-out/Re-start Temperatures °FDB N/A/NIA range Heating Intake Air Temp(Maximum/Minimum) °FDB 59/-13 Healing Thermal Lockout I Re-start Temperatures °FDB -24/-14 Refrigerant Maximum Charge Quantity Lbs,oz 10.0,9.0 Maximum Number of Connected IDU with Branch Box 5(4)- Maximum Number of Connected IDU without Branch Box 12 Indoor unit connection Minimum Number of Connected IDU with Branch Box 12.000 Minimum Number of Connected IDU without Branch Box 21,000 Maximum connected capacity 54,000 Liquid Pipe Size O.D.(Flared) In.[mm] 3/8[9.52] Gas Pipe Size O.D.(Flared) In.(mm] 518[15.881 Total Piping Length when using Branch Box Ft.[m] 492[150] Total Piping Length without Branch Box Ft.[ml 984[300] Maximum Height Difference a,ODU above IDU Ft.[m] 164(50] Maximum Height Difference a,ODU below IDU Ft.[m] 131[40] Maximum Height Difference a,between branch boxes Ft.[m] 491151 Piping Maximum Height Difference between IDU and IDU without Ft.[m] 49[15] branch box I i, Ft.[m] 49[15] Maximum Piping Length between ODU and Branch Box Ft.[m] 180[55] Farthest Piping Length from ODU to IDU with Branch Box Ft.[m] 262[80] Farthest Piping Length,from ODU to IDU without Branch Box Ft.[m] 492[150] Farthest Piping Length after Branch Box Ft.[m] 82[25] Total Piping Length between Branch Boxes and IDU Ft.[m] 311[95] Maximum Number of Bends for IDU 15 NOTES: AHRI Rated Conditions Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) zHeating at 47°F(Indoor//Outdoor) °F 70 IDS,60 WB H 47 DB,43 WB 'Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB 1117 DB,15 WB Conditions "Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB/15 DB,4 WB Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. I when 1 or more Pl EA7 connected 'a Branch box should be placed within the level between the outdoor unit and indoor units 'O 5°F DB-115°F DB when optional wind baffles are installed i For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%,the outdoorl;unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating ail l the same time. ° li i I it I' I� I i ill I �II i i, Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US it All rights reserved. I III III 0Q.TWOORON ®M r III Air Deflector Vertical Air Deflector ❑ ADVA i Air Outlet Guide Air Outlet Guide(1 Piece) I ❑ PAC-SH96SG-E(two pieces are required) Refrigeration Ball Valve-1/2", ❑ BV12FFS12 Refrigeration Ball Valve-1/4"p, ❑ BV14FFS12 Ball Valve Refrigeration Ball Valve-3/61I ❑ BV38FFSI2 Refrigeration Ball Valve-5/8"1 ❑ BV58FFSI2 3 Port Branch Box 1 ❑ PAC-MKA32BC Branch Box 5 Port Branch Box ❑ PAC-MKA52BC Branch Box Enclosure ❑ BBEA Centralized Drain Pan Central Drain Pan ❑ PAC-SH97DP-E Ili M-Net Control Wire,1,000'Rooll(16-AWG,Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) ❑ CW162S-1000 Control Wire M-Net Control Wire,250'Roll(16-AWG,Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) ❑ CW162S-250 Control/Service Tool Maintenance Tool Interface ❑ PAC-USCMS-MN-1 Brazed Connection ❑ MSDD-50BR-E Distribution pipe Flare Connection i II ❑ MSDD-SOAR-E Drain Socket Drain Socket Ii ❑ PAC-SG60DS-E Hail Guards Hail Guard ❑ HG-A2 14 Gauge,4 wire MiniSplit Cable-250 ft.roll ❑ S144-250 14 Gauge,4 wire MiniSplit Cable-250 ft.roll ❑ SW144-250 14 Gauge,4 wire MiniSplit Cable-50 ft.roll ❑ S144-50 14 Gauge,4 wire MiniSplit Cable-50 ft.roll ❑ SW144-50 Mini-Split Wire 16 Gauge,4 wire MiniSplit Cai,ble-250 ft.roll ❑ S164-250 16 Gauge,4 wire MiniSplit 6able-250 ft.roll ❑ SW164-250 16 Gauge,4 wire MiniSplit Cable-50 ft.roll ❑ 5164-50 16 Gauge,4 wire MiniSplit C16ble-50 ft.roll ❑ SW164-50 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic ❑ DSD-400P Adaptor.1/2"x 3/8" j ❑ MAC-A455JP-E Adaptor.1/2"x 518" ❑ MAC-A456JP-E Port Adapter Adaptor.3/8"x 1/2" li ❑ MAC-A454JP-E Adaptor.3/8"x 5/8" I ii ❑ PAC-SG76RJ-E 18"Dual Fan Stand ❑ QSMS1802M 24"Dual Fan Stand ❑ QSMS2402M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket-Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand—12"High ❑ QSMS1202M Wind Baffle Front Wind Baffle ❑ WB-PA3(two pieces are required) I, p, III I 'II _ it'll i Ili 111 II„ II Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. I�u ® ® -NIT U e e i Unit:mm <Inch> A4! w 61594>OL[ : 6 e� Ntt>6t aCJCt>8Z s� �g �8 v5 ,b w e � amLtz>rLs � o a all i AT s I=> g! $ I ' 10 EE KUMt «>sz I Quuusz °KiA xis Q e � <SuuQs>e[t� amo-uz i� f � a� HINDS I IG e9 R JlE [Y 2 a ge 91 asaS a a �rN>S 3 a Husa>ss auuuz m &C83 �S � as aff N yg 6 6T i I I .I U B s a e m JOA � bLll't>LZ QU4U9Z S � 0 a}}>a 3 8 <vrz>u am-1»z I 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com FORM#MXZ-SM42NAMHZ-202209 ;' + Intertek Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. i Bill To TM Christos Karadimas ' 485 Sutton Place Greenport , NY (347) 891-8828 Hamptons Air Heating And Air Itonditioning Inc. Payment terms Due upon receipt Invoice # 1445. P.O.BOX 121 East Quogue, New York 11942 j Date 11/25/2022 Phone: (631) 655-8120 Email: hamptonsairhvac@gmail.:con! Web: hamptonsair.co Description Installation of Mitsubishi 421 BTU Hyperheat Multi Zone System. 1 st Floor 9K BTU Wall Mount indoor unit for Livingroom/kitchen. 6K BTU Wall Mount indoor unit for bedroom 1 on 1 st floor. 6K BTU Wall Mount indoor unit for bedroom 2 on 1 st floor. - Control wires from air handlers to Condenser will be installed. - New refrigerant lines will be installed from outdoor to indoor unit. - New drain lines will be installed from all indoor air handlers. a . 0 - Exposed refrigerant lines will be cover with line hide. - Isolation Valves will be install to be!able to add a Wallmount at a later date. -Condenser will be placed on 12"stands to prevent snow interfering with efficiency. -Aidoo controller M#AZAI6WSCMEL i S#F01 A482 Unit information: Condenser: M#MXZ-SM42NAMHZ-U1 Page 1of5 i S#13U02069 Indoor units: I M#MSZ-G L09 NA-U 1 S#25E18219 j M#MSZ-G L06 NA-U 1 S#23E99524 I M#MSZ-GL06NA-U1 S#23E99528 5 port Branchbox will'be install in basement. I MAIN ELECTRIC TO OUTDOOR CONDENSER INCLUDED. 48K BTU HyperHeat Mitsubishi Multi Zone System 2nd Floor 24K BTU Wall Mount indoor unitfor;Livingroom/kitchen. 9K BTU Wall Mount indoor unit for Master bedroom on 2nd floor. 6K BTU Wall Mount indoor unit for bedroom 1 on 2nd floor. -Control wires from air handlers,to condenser will be installed. a . -24k BTU wall Mount will have MHK2Ithermostat for comfort control. - New refrigerant lines will be installed from outdoor to indoor unit. - New drain lines will be installed. - Exposed refrigerant lines will be cover with line hide. I - Isolatio i Valves will be install to be;able to add an extra Wallmount air handler at a lbter date. a I' -Condenser will be placed on 12"stands to prevent snow interfering with efficiency. -Aidoo,Controller M#AZAI6WSCMEL S#F01 AXE6 ° Unit information: Condenser: M# MXZ-8C48NAHZ2-U1 S# 18U06228D Indoor units: I ' ' Page 2of5 M#MSZ-G L24NA-U 1 S# 1022921T M# MSZ-G L09 NA-U 1 S#27E21267 M#MSZ-G L06 NA-U 1 S#28E60863 5 Port Branch box will be install in basement. MAIN ELECTRIC TO OUTDOOR CONDENSER INCLUDED. Hamptons Air will Install 2-9K Wallmount at a later date at specific location Basement and New Room for additional amount of$2,500 total. If Entrance needs a 9K Floor mount Hamptons Air will charge only The equipment and will do installation with no additional cost. Terms And Conditions: Residential/Commerical Exclusions: ° Hamptons Air Heating and Air Conditioning is not responsible for the existing system, duct work capacity, design and/or operation.Also not responsible for the the air quality and or mold issues in current system. Modification of duct work and zoning is not included unless specified in estimate. All opening of walls,floor and ceilings to be done by others. Painting and/or patching to be donelby others. Hamptons Air Heating and Air Conditioning is not responsible for any existing leaks in refrigerant piping.Any repairs on refrigerant piping are at an additional cost. This estimate will be valid for 90 days. Payment Terms: Customer shall pay,for the services and or/equipment(including repair and maintenance) furnished by Hamptons Air Heating'and Air Conditioning in accordance with the Contract, of Hamptons Air Heating and Air Conditioning's invoice. Interest will be charged on all accounts not paid when due at the rate of 2% per month,or, if less,the maximum rate allowed by law. In the event the Customer fails to pay Hamptons,Air all amounts which become due under the Contract or agreed price and Hamptons Air refers such matters to a collection agency and or attorney, Customer agrees to pay, in addition to th�.amounts due, any and all costs incurred by Hamptons Air as a result of such action, including reasonable attorneys fees. Your name must be imprinted on the check with the correct address and your telephone number. You will be charged $20.00 for each!returned check and all collection costs, including legal fees, if applicable. Money Orders, Certified Checks, Company Checks and Personal Checks are all accepted. Page 3of5 All check payments should be sent to: Hamptons Air Heating and Air Conditioning PO BOX 121 ° East Quogue, NY 11942 Standard Mitsubishi Warranty Unit comes with a 12 year compressor warranty and 12 year parts if register within 60 days of installation. Hamptons Air will provide a 1-year warranty following the date of installation. PAYMENT TERMS 60% Deposit to secure date of install, design and purchase of equipment. 40 %After installation it's complete.; Subtotal $28,756.00 Tota 1 $28,756.00 Payment Summary . o 12/07/2022 - Bank Transfer $28,756.00 Paid Total $28,756.00 4 Remaining Amount $0.00 Q a Notes: Costumer Qualify for PSEG rebate up to $3,500. Hamptons Air will perform Manual j and submit It to PSEG to get approval letter. Page 4of5 r EXTENDED WARRANTY THAT PEOPLE LOVE **Your Installation May Qualify for Extended Warranty** - Extended 5 Year Labor and Maintenance Warranty - Low Monthly Payment - 100% coverage on any repairs or service,calls on covered equipment - Yearly Maintenance on covered equipment - No surprise repair costs ** Must be signed during the home comfort evaluation process or before completion of installation. ** ** Ask your Comfort Consultant for more information** Hamptons Air ! Christos Karadimas I Page 5of5 C.Karadimas HVAC Load Calculations for Christos Karadimas 485 Sutton Place Greenport, NY 11944 � �!u(� �' R�mIL?�I�I'TIAL HVAC LOADS P Prepared By: . Hamptons Air Heating And Air Conditionin PO BOX 121 East Quogue, NY 11942 Friday,January 20,2023 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads h Elite Software Development,Inc. Hamptonsair Heating&A/C C.Karadimas East Quog ue NY 11942 Page 2 Project Report General Project Information . Project Title: C.Karadimas Project Date: Monday, December 19, 2022 Client Name: Christos Karadimas Client Address: 485 Sutton Place Client City: Greenport, NY 11944 Company Name: Hamptons Air Heating And Air Conditionin Company Address: PO BOX 121 Company City: East Quogue, NY 11942 Desi n Data Reference City: Suffolk County AFB, New York Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 40 Degrees Elevation: 67 ft. Altitude Factor: 0.998 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 10 9 n/a n/a 70 n/a Summer: 83 71 56% 50% 75 30 Check Figures, Total Building Supply CFM: 1,571 CFM Per Square ft.: 0.743 Square ft. of Room Area: 2,116 Square ft. Per Ton: 694 Volume(ft3): 16,928 FB—uilding Loads Total Heating Required Including Ventilation Air: 59,726 Btuh 59.726 MBH Total Sensible Gain: 34,485 Btuh 94 % Total Latent Gain: 2,124 Btuh 6 % Total Cooling Required Including Ventilation Air: 36,609 Btuh 3.05 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\ifixscreens\Documents\Elite Software\Rhvac 9 Projects\C.Karadimas.rh9 Friday, January 20, 2023,4:33 PM Rhvac-Residential&Light Commercial HVAC Loads } Elite Software Development,Inc. Ham�ptonsair Heating&A/C C.Karadimas East Quoq ue NY 11942 Pa e 3 Miscellaneous Report System 1 First Floor Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum . Rel.Hum Dry Bulb Difference Winter: 10 9 80% n/a 70 n/a Summer: 83 71 56% 50% 75 30.17 System 2 Second Floor Outdoor. Outdoor' Outdoor. Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum. Rel.Hum Dry Bulb Difference Winter: 10 9 80% n/a 70 n/a Summer: 83 71 56% 50% 75 30.17 Duct sizing inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.320 AC/hr 0.160 AC/hr 90 CFM 45 CFM Infiltration Actual: 0.320 AC/hr 0.160 AC/hr Above Grade Volume: X 16.928 Cu.ft. X 16,928 Cu.ft. 5,417 Cu.ft./hr 2,708 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 90 CFM 45 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 8.78 = (1.10 X 0.998 X 8.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.47 = (0.68 X 0.998 X 30.17 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 65.84 = (1.10 X 0.998 X 60.00 Winter Temp. Difference) Winter Infiltration Specified: 0.320 AC/hr(41 CFM), Construction: Average Summer Infiltration Specified: 0.160 AC/hr(21 CFM), Construction: Average ---System 2--- Infiltration &Ventilation Sensible Gain Multiplier: 8.78 = (1.10 X 0.998 X 8.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.47 = (0.68 X 0.998 X 30.17 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 65.84 = (1.10 X 0.998 X 60.00 Winter Temp. Difference) Winter Infiltration Specified: 0.320 AC/hr(49 CFM), Construction:Average Summer Infiltration Specified: 0.160 AC/hr(25 CFM), Construction:Average C:\Users\ifixscreens\Documents\Elite Software\Rhvac 9 Projects\C.Karadimas.rh9 Friday, January 20, 2023,4:33 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Hamptonsair Heating&A/C C.Karadimas East Quo ue NY 11942 Page 4 Load Preview Report Net ft.' San Lat Net Sen Mir] Min Sys Sys Sys Scope Ton /Ton Area Gain Gain Gain Loss Htg Clg Htg Clg Act CFM'' CFM CFM CFM CFM Buildinq 3.05 694. 2,116 34,485 2,124 36,609 59,726 778 -1,571 778 1,571 1,571 Svstem 1 First Floor 1.46 663 966 16,468 1,022 17,490 27,591 359:'. 750 359 I 750 750 Zone 1 966 16,468 1,022 17,490 27,591 359 750 359 _ 750 1-First Floor 966 16,468 1,022 17,490 27,591 359 750 359 f 750 Svstem 2 Second Floor 1.59 722 1,150 18,017 1,102 19,119 32,135 418� 821 418 821 Zone 1 1,150 18,017 1,102 19,119 32,135 418. 821 418 821 2-Second Floor 1,150 18,017 1,102 19,119 32,135 418..' 821 418 '_ 81 821 I C:\Users\ifixscreens\Documents\Elite Software\Rhvac 9 Projects\C.Karadimas.rh9 Friday, January 20, 2023,4:33 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Iric. Hamptonsair Heating&A/C1r C.Karadimas East Quoq ue NY 11942 Pa e 5 Duct Size Preview Room or SourceFMVielocityl nimum Maximum Rough. Design SP Duct Duct Htg Clg Act. Duct Reg Duct Name Velocity Factor U100 Loss Velocity Length Flow Flow Flow Size Size System 1 I Supply Runouts Zone 1 1-First Floor Built-In 0 750 0.01 0.1 401.1 359 MMI 750 7--7 Other Ducts in System 1 Supply Main Trunk Built-In 0 900 0.003 0.1 720.4 359 NMI 750 10.15 System 2 Supply Runouts Zone 1 2-Second Floor Built-In 0 750 0.01 0.1 384 418 NMI 821 8--7 Other Ducts in System 2 Supply Main Trunk Built-In 0 900 0.003 0.1 738.8 418 NMI ! 821 10x16 Summary Svstem 1 Heatinq Flow: 359 Coolinq Flow: 750 Svstem 2 Heatinq Flow: 418 Coolinq Flow: 821 I C:\Users\ifixscreens\Documents\Elite Software\Rhvac 9 Projects\C.Karadimas.rh9 Friday, January 20, 2023, 4:33 PM i Rhvac-Residential&Light Commercial HVAC Loads , Elite Software Development,Inc. Hamptonsair Heating&A/C C.Karadimas East Quog ue NY 11942 Pa e 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 1A-cm-o: Glazing-Single pane, operable window, clear, 313 23,852 0 13,842 13,842 metal frame no break, U-value 1.27, SHGC 0.75 11J: Door-Metal- Fiberglass Core, U-value 0.6 18 648 0 205 205 12B-Osw: Wall-Frame, R-11 insulation in 2 x 4 stud 1877 10,924 0 3,115 3,115 cavity, no board insulation, siding finish, wood studs, U-value 0.097 166-7: Roof/Ceiling-Under Attic with Insulation on Attic 2116 14,220 0 10,190 10,190 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-7 insulation, U-value 0.112 1913-0sp: Floor-Over enclosed crawl space, R-4 2116 4,137 0 552 552 insulation on exposed walls, sealed crawl space, passive, no floor insulation, carpet or,hardwood, U- value 0.368 Subtotals for structure: 53,781 0 27,904 27,904 People: 6 1,200 1,380 2,580 Equipment: 0 3,600 3,600 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 90, Summer CFM: 45 5,945 924 396 1,320 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 1,205 1,205 Total Building Load Totals: 59,726 2,124 ' 34,485 36,609 Check Figures Total Building Supply CFM: 1,571 CFM Per Square ft.: 0.743 Square ft. of Room Area: 2,116 Square ft. Per Ton: 694 Volume(ft'): 16,928 FB-uilding Loads Total Heating Required Including Ventilation Air: 59,726 Btuh 59.726 MBH Total Sensible Gain: 34,485 Btuh 94 % Total Latent Gain: 2,124 Btuh 6 % Total Cooling Required Including Ventilation Air: 36,609 Btuh 3.05 Tons(Based.On Sensible+ Latent) Notes, i Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\ifixscreens\Documents\Elite Software\Rhvac 9 Projects\C.Karadimas.rh9 Friday, January 20, 2023, 4:33 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Harnotonsair Heating&A/C C.Karadirna' s! East Quo g ue, NY 11942 Pa 7 Building Pie Chart Floor 7% Infiltration 10% Door 1% P Roof 240% C Glass 40% Wall 18% Floor 2% AED Excursion 3% Infiltration 4% Equipment 10% Roof 28% People 7% Door 1% Wall 9% Glass 38% C:\Users\iflxscreens\Documents\Elite Software\Rhvac 9 Prpjects\C.Karadimas.rh9 Friday, January 20, 2023,4:33 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Hamptonsair Heating&A/C. C.Karadimas East Quo ue'NY 11942 Pa e 8 Detailed Room Loads - Room 1 - First Floor (Average Load Procedure General Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: '21.0 ft. System Number: °. 1 Room Width: ;'46.0 ft. Zone Number: 1 Area: 966.0 sq.ft. Supply Air: 750 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.8 AC/hr Volume: 7;728 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 7 Actual Winter Vent.: 0 CFM Runout Air: 107 CFM Percent of Supply.: 0 % Runout Duct Size: j 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: , 401 ft./min. Percent of Supply: 0 % Runout Air Velocity: 401 ft./min. Actual Winter Infil.: 41 CFM Actual Loss: 0.084 in.wg./100 ft. Actual Summer Infil.: 21 CFM Item Area -U- Htg Sen Clg Lat Sen Description Quantity Value HTM Loss HTM Gain Gain N -Wall-126-0sw 46 X 8 312 0.097 5.8 1,816 1.7 0 518 E-Wall-1213-0sw 21 X 8 136 0.097 5.8 792 1.7 0 226 S-Wall-1213-0sw 46 X 8 300 0.097 5.8 1,746 1.7 0 498 W-Wall-1213-0sw 21 X 8 168 0.097 5.8 978 1.7 0 279 N -Door-11 J 3 X 6 18 0.600 36.0 648 11.4 0 205 N-GIs-1A-cm-o shgc-0.75 100%S 18 1.270 76.2 1,372 24.7 0 444 (2) N -GIs-1A-cm-o shgc-0.75 100%S 20 1.270 76.2 1,524 24.7 0 493 E-GIs-1A-cm-o shgc-0.75 0%S(2) 32 1.270 76.2 2,438 80.9 0 2,590 S-GIs-1A-cm-o shgc-0.75 0%S 36 1.270 76.2 2,743 41.0 0 1,476 S-GIs-1A-cm-o shgc-0.75 0%S l; 4 1.270 76.2 305 41.0 0 164 S-GIs-1A-cm-o shgc-0.75 0%S 20 1.270 76.2 1,524 41.0 0 820 S-GIs-1A-cm-o shgc-0.75 0%S 8 1.270 76.2 610 41.0 0 328 UP-Ceil-166-7 21 X 46 966 0.112 6.7 6,492 4.8 0 4,652 Floor-1913-0sp 46 X 21 966 0.368 2.0 1,889 0.3 0 252 Subtotals for Structure: „ 24,877 0 12,945 Infil.:Win.: 41.2, Sum.: 20.6 1,072 2.532 2,714 0.169 422 181 AED Excursion: 252 People: 200 lat/per, 230 sen/per: 3 600 690 Equipment: 0 2,400 Room Totals: 27,591 1,022 16,468 Equipment,Cooling Loads Cont. Cont. " Output Output Avg. Pct Sens. Lat. Sens. Lat. In-Use "'Used Load Load Item Name Btuh Btuh 'Output a/,Hour Btuh Btuh Whole House Scenario Option 1, Refrigerator, range with 2400 0 100 .100 2400 0 hood, dishwasher, clothes washer and vented clothes dryer, electronic equipment and lighting allowance. Note: 1000 Btuh for the kitchen, 500 Btuh for the utility room, 900 Btuh allowance for a TV or computer and a lighting fixtures.-_ Total 2400 0 C:\Users\ifixscreens\Documents\Elite Software\Rhvac 9 Projects\C.Karadimas.rh9 Friday, January 20, 2023,4:33 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Hamptonsair Heating'&A/C S1114t C.Karadimas .East Quo ue NY 11942l Pa e 9 Detailed Room Loads - Room 2 - Second Floor (Average Load Procedure General . Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 25.0 ft. System Number: 2 Room Width: 46.0 ft. Zone Number: 1 Area: 1,150.0 sq.ft. , Supply Air: 821 CFM Ceiling Height: I�, 8.0 ft. Supply Air Changes: 5.4 AC/hr Volume: 91,200 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 8 Actual Winter Vent.: 0 CFM Runout Air: 103 CFM Percent of Supply.: 0 % Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 384 ft./min. Percent of Supply: 0 % Runout Air Velocity: �,,384 ft./min. Actual Winter Infil.: 49 CFM Actual Loss: 0.077 in.wg./100 ft. Actual Summer Infil.: 25 CFM Item Area -U- Htg Sen Clg Lat Sen Description Quantity :' Value HTM,. : Loss HTM Gain Gain N -Wall-1213-0sw 46 X 8 292 0.097 5.8 1,699 1.7 0 484 E-Wall-1213-0sw 25 X 8 200 0.097 5.8 1,164 1.7 0 332 S-Wall-1213-0sw 46 X 8 j; 309 0.097 5.8 1,798 1.7 0 513 W-Wall-1213-0sw 25 X 8 160 0.097 5.8 931 1.7 0 265 N -GIs-1A-cm-o shgc-0.75 100%S 20 1.270 76.2 1,524 24.7 0 493 N -GIs-1A-cm-o shgc-0.75 100%S 24 1.270 76.2 1,829 24.6 0 591 N -GIs-1A-cm-o shgc-0.75 100%S 16 1.270 76.2 1,220 24.6 0 394 (2) N -GIs-1A-cm-o shgc-0.75 100%S 16 1.270 76.2 1,219 24.6 0 394 S-GIs-1A-cm-o shgc-0.75 O%S ! 24 1.270 76.2 1,829 41.0 0 984 S-GIs-IA-cm-o shgc-0.75 0%S ! 9 1.270 76.2 686 41.0 0 369 S-GIs-1A-cm-o shgc-0.75 0%S 6 1.270 76.2 457 41.0 0 246 S-GIs-1A-cm-o shgc-0.75 0%S 20 1.270 76.2 1,524 41.0 0 820 W-GIs-IA-cm-o shgc-0.75 0%S(2) 40 1.270 76.2 3,048 80.9 0 3,236 UP-Ceil-1613-7 25 X 46 j' 1150 0.112 6.7 7,728 4.8 0 5,538 Floor-1913-0sp 46 X 25 1 1150 0.368 2.0 2,248 0.3 0 300 Subtotals for Structure: 28,904 0 14,959 Infil.:Win.: 49.1, Sum.: 24.5 j' 1,136 2.844 3,231 0.189 502 215 AED Excursion: j, 953 People: 200 lat/per, 230 sen/per: 3 600 690 Equipment: 0 1,200 Room Totals: 32,135 1,102 18,017 E ui ment Cooling Loads Cont. Cont. ' Output Output _' Avg.. P,ct Sens. Lat. Sens. Lat. ; In-Use Used Load Load Item Name Btuh Btuh ' Output /Hour Btuh Btuh Whole House Default Appliance Load, Refrigerator and 1200 0 100 100 1200 0 range with vented hood. Note: 12001 Btuh applied to the kitchen. Total 1200 0 I j, I C:\Users\ifixscreens\Documents\Elite So I ftware\Rhvac 9 Projects\C.Karadimas.rh9 Friday, January 20, 2023,4:33 PM d ; Rhvac.'Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Hamptonsair Heating&A/C C.Karadimas East Quo ue NY 11942 Page 10 S stem 9 Room Load Sum mar Htg Min 'Run Run Clg Cig Min. Act Room Area i Sens, Htg Duct Duct Sens Lat Cig Sys No Name SF : Btuh CFM Size Vel i Btuh Btuh CFM CFM ---Zone 1--- 1 First Floor 966 �27 591 359 7-7 401 16,468 1,022 750 750 System 1 total 966 27,591 359 16,468 1,022 750 750 System 1 Main Trunk Size: 1'Ox15 in. Velocity: 1720 ft./min Loss per 100 ft.: 0.092 in.wg Fa6linq System;Summary Cooling Sensible/Latent, ' 'Sensible Latent Total Tons ..Split , Btuh .i Btuh Btuh Net Required: 1.46 94%/6% 16,468 1,022 17,490 E ui ment Data Heating System Cooling System Type: Natural Gas Furnace Standard,Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 10 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh III ' ; I ; I i . I � o C:\Users\ifixscreens\Documents\Elite Software\Rhvac 9 Projects\C.Karadimas.rh9 Friday,.January 20, 2023,4:33 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Hamptonsair Heating&A/C , C.Karadimas East Quo ue NY 11942 ' Pa a 111 S stem 2 Room Load Suminar Htg Min : Run Run Clg Cl Min Act Room Area Sens Htg : Duct Duct Sens Lat Clg Sys No Name SE Btuh CFM ' .- Size Vel Btuh Btuh CFM CFM ---Zone 1--- 2 Second Floor 1,150 132,135 418 8-7 384 18,017 1,102 821 821 System 2 total 1,150 132,135 418 18,017 1,102 821 821 System 2 Main Trunk Size: i1,0x16 in. Velocity: 739 ft./min Loss per 100 ft.: 0.094 in.wg FC—ooling System Summary Cooling Sensible/,Latent Sensible Latent Total Tons Split Btuh ' Btuh Btuh Net Required: 1.59 I'' 94%/6% 18,017 1,102 19,119 [tcidipment Data, Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh I I it i II i II II I C:\Users\ifixscreens\Documents\Elite Software\Rhvac 9 Projects\C.Karadimas.rh9 Friday, January 20, 2023,4:33 PM I MULTI-ZONE Job Name: System Reference: Date: t' �r?h�tti JfiW� FEATURES Variable speed INVERTER-driven compressor Blue Fin Coating Heat Exchanger Thermal Differential 1°F(with PAC-MKA32/52BC only) Branch box for simplified piping and installation flexibility Up to 8 indoor units connectable(six[6]if a PLA-A"EA7 is connected) Built-in base pan heater Quiet outdoor unit operation as low as 54 dB(A) High pressure protection Compressor thermal protection Compressor overcurrent detection Fan motor overheating/voltage protection H2i®hyper heat performance offers 100%heating capacity at 5°F and 74%heating capacity at-13°F I i Cnorifir�tinnc�ru etthier+M r•hnnne—ifhntt+nnfi— 0)7(17f1 h/lif—Kiehi Fler+rir•T—ne 1-I%/Af`1 IC I 1 r% All rink+c mconierl cc SPECIFICATIIONS., i O Indoor unit type Non-Ducted Mi x Ducted Maximum Capacity BTU/H 48,000 48,000 48,000 + Rated Capacity BTU/H 48,000 48,000 48,000 Minimum Capacity BTUlH 16,000 16,000 16,000 Cooling Maximum Power Input W 3,930 4,320 4,800 Rated Power Input W 3,930 4,320 4,800 Power Factor(208V,230V) % 98.6/98.6 98.9/98.9 99.2/99.2 Maximum Capacity BTU/H 54,000 54,000 54,000 Rated Capacity BTU/H 54,000 54,000 54,000 Minimum Capacity BTU/H 27,000 27,000 27,000 Heating at 47°FZ ' Maximum Power Input W 4,220 4,520 4,800 Rated Power Input W 4,220 4,520 4,800 Power Factor(208V,230V) % 98.6/98.6 98.9/98.9 99.2/99.2 Maximum Capacity BTU/H 54,000 54,000 54,000 Rated Capacity BTU/H 38,000 38,000 38,000 Heating at 17°F3 Maximum Power Input W 6,870 7,640 8,400 Rated Power Input W 4,130 4,370 4,650 Maximum Capacity BTU/H 54,000 54,000 54,000 Heating at 5°F4 Maximum Power Input W 7,910 8,330 8,790 SEER 20.00 18.00 16.00 EERI 12.20 11.10 10.00 HSPF(IV) 11.5 10.8 10.1 Efficiency COP at 47°F2 3.75 3.50 3.30 COP at 17°F3 2.30 2.00 1.80 COP at 5°F4 2.00 1.90 1.80 ENERGY STAR®Certified NO NO NO Voltage,Phase,Frequency 208/230V,1-phase,60 Hz Guaranteed Voltage Range VAC 198-253 Voltage:Indoor-Outdoor,S1S2 VAC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current i Rating(SCCR) 5kA 5 s Recommended Fuse i/Breaker Size(Outdoor) A 45 Recommended Wire Size(Indoor-Outdoor) AWG 16 MCA A 42 MOCP A 50 Fan Motor Full Load Amperage A 0.6+0.6 Fan Motor Output W 74 Airflow Rate Cooling'/Heating CFM 3,885/3,885 Refrigerant Control Linear Expansion Valve 4 Defrost Method Reverse Cycle Heat Exchanger Type',I Plate Fin Coil Outdoor unit Sound Pressure Level;Cooling' dB(A) 51 Sound Pressure Level,Heating2 dB(A) 54 Compressor Type Hermetic Compressor Model ANB33FJSMT Compressor Motor Output kW 3.4 Compressor Rated Load Amps A 19.0 Compressor Locked Rotor Amps A 22.0 Compressor Oil Type!/Charge oz. FV50S//73 External Finish Color Munsell 3Y 7.8/1.1 Cnerifinofinne ero ciihior•f•tn rhnnna-4h-4 nntire (r. •7l170 11Aifaiihichi 1=lo +rir Tronn I-1\/A(` I IC I I r` All rinhfe reenninrl i i 4i Indoor unit type Non-Ducted mix, Ducted Base Pan Heater Built-in W:In. 41-11132[1,050] [mm] Unit Dimensions D:In. 13[330] [mm] H:In. 52-11/16(1,338] [mm] W:In. 42-15/16[1,090] [mm] Package Dimensions D:In. 17-3/4[450] [mm] H:In. 56-5/16[1,430] [mm] Unit Weight Lbs.]kg] 278[126] Package Weight Lbs.[kg] 302[137] Cooling Intake Air Temp(Maximum/Minimum*) °F 115 DB/23'c DB Cooling Thermal Lock-out/Re-start Temperatures -1/3 Outdoor unit operating temperaturOange Heating Intake Air Temp(Maximum/Minimum) °F 70 DB/-13 DB Heating Thermal Lockout/Re-start Temperatures °F -181-14 Type R410A R410A R410A Refrigerant 'Y - Charge Lbs,oz 10 Ibs 9 oz 10 Ibs 9 oz 10 Ibs 9 oz Maximum Number of'Connected IDU 8(6'A) Minimum Number of Connected IDU 2 Indoor unit connection Maximum connected icapacity BTU/H 62,000 Minimum connected capacity, BTU/H 12,000 Gas Pipe Size O.D.(Flared) In.[mm] 5/8[15.88] Liquid Pipe Size O.D�(Flared) In.[mm] 3/8[9.52] Total Piping Length Ft.[m] 492[150] Maximum Height Difference'B,ODU above IDU Ft.[m] 164[50] Maximum Height Di ference'B,ODU below IDU Ft.[m] 131[40] Maximum Height Difference B,between branch boxes Ft.[m] 49[15] Piping Maximum Height Difference s,between branch boxes and IDU Ft.[m] 49[15] Max.Piping Length between ODU and Branch Box Ft.[m] 180[55] Farthest Piping Lenglh from ODU to IDU Ft.[m] 262[80] Farthest Piping Lengthlafter Branch Box Ft.[m] 82[25] Total Piping Length between Branch Boxes and IDU Ft.[m] 311[95] Maximum Number of Bends for IDU 15 Maximum Number of Bends for ODU 120 Notes f cooking(Indoor//Outdoor) °F 80 DB,67 WB H 95 DB,75 WB AHRI Rated Conditions(Rated data is determined at a fixed 2Healing at 47°F(Indoor U Outdoor) °F 70 DB,60 WB//47 DB,43 WB compressor speed) 30eafing at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions °bleating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,5 WB 'Applications should be restricted to coofort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. •A when 1 or more PLA-A.EA7 connect 'B Branch box should be placed within the level between the outdoor unit and indoor units 'c 5°F DB-115°F DB when optional-wind baffles are installed For reference to connected capacity t h'arts,please refer MXC Series Operational Performance. Although the maximum conneclable:rapacity is 130%,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Cnerifino#innc ore...KierYfn Gl 7n)n K114-il iehi Fle frir Trine uvnr 1 IC I I rr All rink#e m—n—A i eCCESSORIES: MXZ-8C48NAHZ2 0. Distribution pipe for Branch box(Flq{13 Connection) ❑MSDD-50AR-E Distribution pipe for Branch box(Brazed Connection) ❑MSDD50BR-E Port Adapter size:3/8"x 5/8" ❑PACSG76RJ-E Port Adapter size:1W x 3/8" ❑PAC493PI Port Adapter size:3/8"X 1/2" ❑MAC-A454JP-E Port Adapter size:1/2"X 3/8" ❑MAC-A455JP-E Port Adapter size:1/2"X 5/8" *'• ❑MAC-A456JP-E Branch Box ❑PAC-MKA52BC Branch Box ❑PAC-MKA32BC Branch Box Outer Cover ❑BBE-1 Air Outlet Guide ❑PACSH96SG-E(two pieces are required) Front Wind Baffle o WB-PA3(two pieces are required) Centralized Drain Pan ❑PAC-SH97DP-E Hail Guard !, ❑HG-A2 Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic ❑DSD-400P Condensing Unit Mounting Pad 16"x;W6 x 3" ❑ULTRILITE1 Outdoor Unit Stand—12"High ❑OSMS1202M Outdoor Unit Stand-18"High ❑QSMS1802M Outdoor Unit Stand-24"High o QSMS2402M Heavy Duty Wall Mounting Bracket--�Cdated Steel ❑QSWB2000M-1 Heavy Duty Wall Mounting Bracket—315 Series Stainless Steel o QSWBSS 10'x 3/8"x 10'x 5/8"Lineset(Twin-Tubg Insulation) ❑MPLS385812T-10 15'x 3/8"x 15'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-15 30'x 3/8"x 30'x 5/8"Lineset(Twin-Tube Insulation) o MPLS385812T-30 50'x 3/8"x 50'x 5/8"Lineset(Twin--Gbe-Insulation) ❑MPLS385812T-50 65'x 3/8"x 65'x 5/8"Lineset(Twin-lube�lnsulalion) ❑MPLS385812T-65 1 00'x 3/8"x 1 00'x 5/8"Lineset(Twirj-Tube Insulation) ❑MPLS385812T-100 i t 7 Qn—ifi—fin no ore a ihi—f 4 hhonne—ifhni i+nnfiro nr 7/170 114 ifemihichi IP:I—frir Trone uvAr%1Ic 1 1 rr All Anhfe mom—erl iCUM HZ2 Outdoor unit MXZ-4C36NAHZ2-U1 MXZ-8C48NAHZ2-U1 MXZ-5C42NAHZ2-U1 MXZ-8C60NA2-U1 MXZ-8C48NA2-U1 4HP 4.5HP 5HP 7HP Rated capacity Cooling 36 42 48 60 (kBtu/h):. Heating 45 48 54 66 Refrigerant R410A Connectable Capacity`class Type 06 to Type 36 indoor unit Caution: The indoor unit which rated capacity exceeds 36 kBtu/h(Type 36)can NOT be connected. Number"bf units 2('')to 4 units 2('')to 5 units 2('')to 8 units 2('')to 8 units Total system capacity range 33 to 130%of outdoor 29 to 130%of outdoor 25 to 130%of outdoor 20 to 130%of outdoor unit capacity unit capacity unit capacity unit capacity (12 to 46.8 kBtu/h) (12 to 54.6 kBtu/h) (12 to 62.4 kBtu/h) (12 to 78 kBtu/h) Connectable NumberAf units 1 or 2 units branch box Connectable indoor unit lineups(Heat pump'inverter type) Model type Model name Capacity class[kBtu/hl 06 09 12 15 18 24 30 36 Deluxe Wall-mounted MSZ-FH06/09/12/15NA,18NA2 Designer MSZ-EF09/12/15/18NA(W/B/S) Standard Wall-mounted MSZ-GL06/09/12/15/18/24NA Low static ducted-4• i SEZ-KD09/12/15/18NA P-series mid static ducted•` PEAD-A0 9/1 211 5/1 8/24/3 013 6AA7 1-way cassette MLZ-KP09/12/18NA P-series 22*22 4-way:cassette SLZ-KF09/12/15NA P-series 33*33 4-way,'cassette PLA-Al2/18/24/30/36EA7'5 Floor standing MFZ-KJ09/12/15/18NA Standard Multkposition air handler z SVZ-KP12/18/24/30/36NA Branch box PAC-MKA52BC PAC-MKA32BC' Number of,branches 5 branches 3 branches (Indoor unit that can be connected) (MAX.5 units) (MAX.3 units) Note:A maximum of 2:15ranch boxes can be connected to 1 outdoor unit. 2-branch pipe(joint)'.Optional parts In the case of using 1-branch box No need In the case of using 2-branch boxes Model name Connection method r MSDD-50AR-E flare Select a model according to the connection method. MSDD-50BR-E brazing Option Optional accessories for indoor units and outdoor units are available. Only one unit connection is possible with ducted unit. '2 When connecting a multii-position unit(s),set additional constraints as follows.For connections other than those specified below,consult your dealer. •Models other thfin MXZ-8C60NA2(For each connected branch box) •MXZ-8C60NA2(For each connected branch box) Number of connebting. Number of connecting multi-position unit Constraints multi-position unit Constraints Any indoor units other than ducted units are not Any indoor units other than ducted unit are not 2 connectable. 2 connectable. The total system wide capacity should be 130%or The total system wide capacity should be 100%or 1 below including the ducted unit. 1 below including the ducted unit. Only 1 ducted unit can be included in the connection. Only 1 ducted unit can be included in the connection. s For MXZ-8C60NA2;When connecting the SEZ and PEAD-series units,the total system wide capacity per 1 branch box should be 100%or below including the ducted units.(Only if conhecting to branch box) °When not outside u4s 60:A branch box can connect to maximum 3 of the ducted units.When connecting with 3 of the ducted units per 1 branch box,other indoor units cannot be connected. When outside units 60:A branch box can connect to maximum 2 of the ducted units.When connecting with 1 and over 1 of the ducted units,the total ability including of the ducted units is 100%and below 100%. 'S When the system includes 1 unit of ducted units,,the number of the maximum connectable indoor units is decreased as follows: 3 for 1V1XZ4C36NAIjZ2-111,4 for MXZ-5C42NAHZ2-U1,and 6 for MXZ-8C48NA(HZ)2-U1 and MXZ-8C60NA2-U1 NOTE Please referAd:Application Note 1039 for more information and exceptions to these rules. Qncnifin.finnc nrn enhicrf fn 0)W)W)h/14 kichi Flonfrir Trnno I-I\/Ar'1 IQ I I r All rinhfc mcnm—rl SYSTEM DE'SIGN: • • Piping connectiori:size A B 03/8.inch The piping connection size differs according to the type and capacity of indoor units. Liquid Match the piping connection size of branch box with indoor unit. [9.52.frm] p�p� 9 If the piping connection size of branch box does not match the piping connection size of Gas 05/8 inch / 3/4 inch* indoor unit, use optional different-diameter(deformed)joints to the branch box side. [15.88 mm] [99.05 mm] (Connect deformed joint directly to the branch box side.) *MXZ-8C60 only ■ In case of using 1-branch box Flare connection employed (No brazing) Branch box r A. :j i EB B B B B i ■ In case of using 2-branch boxes 2 branches pipe (joint) optional parts A. A Branch box#1 A B B', B B B Branch box#2 ■ Installation procedure(2 branches pipe Qoint)) Refer to the installation manuals of MSDD-50AR-E and MSDD-50BR-E. It Cnorifirofinnc pro ciihiorf fn jhonne uiifhnf nnfino 0)WYN)h/14 Kichi Flerfrir Tr-WXIA('11e 1 1 rr All rinhfe roeen 4