Loading...
HomeMy WebLinkAbout49424-Z Suffat�r a0�0 ppGy Town of Southold 2/4/2024 ' P.O.Box 1179 53095 Main Rd yip! �a 5 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44924 Date: 2/4/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 2015 Gabriella Ct,Mattituck SCTM#: 473889 Sec/Block/Lot: 108.4-7.53 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/25/2023 pursuant to which Building Permit No. 49424 dated 6/27/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as appllied for(maintain 36 inch clearance from shrubs). The certificate is issued to DeMarco,Gerard&Theresa of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49424 7/26/2023 PLUMBERS CERTIFICATION DATED u h iz d Signature TOWN OF SOUTHOLD t%�SUFfOlpco moo oy� BUILDING DEPARTMENT y x r TOWN CLERK'S OFFICE "oy • � �� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49424 Date: 6/27/2023 Permission is hereby granted to: DeMarco, Gerard 2016 Gabriella Ct Mattituck, NY 11952 To: Install an accessory generator to an existing single family dwelling as appllied for. Must maintain a minimum setback of 15 feet. At premises located at: 2015 Gabriella Ct, Mattituck SCTM #473889 Sec/Block/Lot# 108.4-7.53 Pursuant to application dated 6/26/2023 and approved by the Building Inspector. To expire on 12/2612024. Fees: ACCESSORY $100.00 CERTIFICATE OF OCCUPANCY $50.00 ELECTRIC $85.00 Total: $23 5.00 Building Inspector pF SO!/T�ol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box H79 a� sean.devlina-town.southold.ny.us Southold,NY 11971-0959 O COUNN BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Garard DeMarco Address: 2015 Gabriella Ct city:Mattituck st: NY zip: 11952 Building Permit#: 49424 section: 108 Block: 4 Lot: 7.53 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Custom Lighting of Suffolk License No: 38893ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service t ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 20kW Generator w/200A Whole House Transfer Switch Notes: Generator Inspector Signature: Date: July 26, 2023 S.Devlin-Cert Electrical Compliance Form L ,O Ll f SOUTy�Io (r 1 ✓ / �5�A41 dPt # # TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ RE C/O [ ] RENTAL REMARKS: DATE - INSPECTOR souryO� # # TOWN OF SOUTHOLD BUILDING DEPT. �ycoumv,, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: nCtD'1 b (O0" G 16) vtdn m6n-, T�;i� La-4 C&14 DATE l I '1,o'Y INSPECTOR A M P Arch itectu re Address:10200 Main Road,Unit 3A,Matti tuck NY 11952 • • .• Design + Build 1 ti � •�' /J�� ti ,� .� ~ ,^fit �� � -��.. r c � A M P Architecture Address:10200 M a in Road,Unit 3A,Matt ituck NY 11952 • • .• January 12",Design + Build Demarco Residence-Pictures for CO Town Of Southold Building Department 54375 Main • P.O. Box 1179 Southold, 3 � ,`••• .i-;tee °"'� w �r t�.. ♦ r a ' so Town Hall Annex ; Telephone(631)765-1802 54375 Main Road P.O.Box I t79 sean.devlin aetown.southold.ny.us Southold,NY 11971-0959 D• '`` BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Gerard DeMarco Address: 2015 Gabriella Ct city:Mattituck st: NY zip: 11952 Building Permit#: 47897 section_ 108 Block: 4 Lot: 7.53 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor. Electrician: CLOS License No: 38893ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor X Pool House X New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 15 Ceiling Fixtures 2 Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures 1 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 27 CO2 Detectors Sub Panel X A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 3 4'LED Exit Fixtures Sump Pump Other Equipment: 20 Circuit Panel / 10 Used Notes: Pool House w/Outdoor BBQ Inspector Signature: Date: March 20, 2023 S.Devlin-Cert Electrical Compliance Form •g a ! FIELD INSPECTION REPORT DATE COMMENTS � ro FOUNDATION(IST) y ' ------------------------------------ S rA FOUNDATION (2ND) tr1 z 6 � kAcn y ROUGH FRAMING& o PLUMBING �- � 1 Lw N= r INSULATION PER N.Y. STATE ENERGY CODE m It FINAL ADDITIONAL POMMENTSWN t`O d� m �O H O z x d r� ro H ,�S-ufFacK coGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT C. a; Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only U 0 PERMIT NO. 1 q Building Inspector: MAY dUILUINUUEPT. Applications and forms must be filled out in theirentirety.Incomplete Towhi(1FSf11m4ni n applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:05/22/23 OWNER(S)OF PROPERTY: Name:Gerry & Theresa Demarco scTM#1000-108-4-7.53 Project Address:2015 Gabriella Court Mattituck NY 11952 Phone#:347-907-2057 Email:gmta40004•@yahoo..com Mailing Address:2015 Gabriella Court Mattituck NY 11952 CONTACT PERSON: Name:Michelle Sarabia, AMP Architecture Mailing Address: 10200 Main Road Unit 3A Mattituck NY 11952 Phone#:631-603-9092 Email:msarabia@ampgr..hitect.com DESIGN PROFESSIONAL INFORMATION: Name:Anthony Portillo,, AMP Architecture Mailing Address: 10200 Main Road Unit 3A Mattituck NY 11952 Phone#:631-603-9092_. .,.. ._.._ _. ____•.._. Email:aportillo@amparchitect.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION, ❑New Structure ❑Addition ❑Alteration ❑Repair El Demolition Estimated Cost of Project: 0 Other Generator $ Will the lot be re-graded? ❑Yes ©No Will excess fill be removed from premises? ❑Yes BNo 1 P RO PE IlTY.I N FORMATION, Existing use of property: »LE5, Intended use of property: zone or use district in which premises is situated: Are there any covenan and restrictions with respect to G 00r,%- fv r this property? Yes No IF YES,PROVIDE A COPY. Chei:(cBox After Readirsg:"The owner/coet�actor/design.prof6isidnal is resp6nsible for all drainage and.storm.water issues as provided by Chapter 236 of the Town Code' P6eATigN;IS HEREBY MAD[:to the B ilidi Department for the issuance of a.Building'Permit pursuant to-the Buiitling Zone Oidinance'.of the Towo of southold;Suffolk;6unty,New York;and ot6erappl'icable;laves,Ordinances or Regulations;fog the;constiuction of buildings; -.additions;alterations or for removal or demofttion as herein descn6ed:The applicant agrees to comply with all applicable lain;s;ordioamc s,,bwldm ' g,code, housing code and regulationsana-to admt'authorized inspectors on premises;and_in 6uilding(s)for necessary inspe"ct ions.,Falsestatements made herein are_ punishable as.a.Class A misdemeanor pursuanf fo Section 210 45pfih'e New York State.Penal Law. Application Submitted Tint n � ;-�-� « Authorized Agent ❑Owner • P C�5 �- Signature of Applica t: Date: J J STATE OF NEW YORK) SS: COUNTY OF H'1Ch(Q11C 5 O being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, L (S)he is the Cal,A 37r (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file there ' h. Sworn before me this i _d3Lday of I 202ea Notary Public De=&OrloWskl ,:' . Notary Public Stte a of Flew Yor NWAW PROPERTY.O WNERAUTHORIZATI®N=*: welic * No.0IM628DM Qualified in Suffolk Canty (Where the applicant is not the owner) Comualsaton Expim O5l13120 I, LQ.,V-O%-r8 tJSL t/� ev«-O residing at / O[7i CA671 RA 01 000'4- do hereby authorize AMP ARCHITECTURE to apply on my beha the T n of thold Building Department for approval as described herein. Owner's Signature Date erq✓,� lemccy-6 J Print Owner's Name 2 �O��g�FFO(�CO BUILDING DEPARTMENT- Electrical Inspector Gyr► TOWN OF SOUTHOLD CO Town Hall Annex- 54375 Main Road - PO Box 1179 W 'x Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roQerr a-southoldtownny.Qov — seanda-southoldtownny.Qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 06.30.23 Company Name: Custom Lighting of Suffolk Inc Electrician's Name: Benjamin Doroski License No.: 38893-ME Elec. email:CLOS5170@gmail.com Elec. Phone No: 631-298-4588 E I request an email copy of Certificate of Compliance Elec. Address.: PO Box 1698 Mattituck NY 11952 JOB SITE INFORMATION (All Information Required) Name: Demarco Pool House Address: 2015 Gabriella Ct, Mattituck, NY 11952 Cross Street: Tabor Rd Phone No.: 6316039092 Bldg.Permit#: Generator L4email: amarra@amparchitect.com Tax Map District: 1000 Section: 108 Block: 04 Lot: 7.53 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New gas powered generator Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES ❑ NO ❑Rough In 0 Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION �JufFOI � BUILDING DEPARTMENT- Electrical Inspector �® f®$ TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 r Southold, New York 11971-0959 a— . a4Ik-I Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrna southoldtownny.gov — sea ndCaD-southoldtownny.gov '-'7. •L i::i APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 06.30.23 Company Name: Custom Lighting of Suffolk Inc - Electrician's Name: Benjamin Doroski License No.: 38893-ME Elec. email:CLOS5170@gmail.com Elec. Phone No: 631-298-4588 0✓ I request an email copy of Certificate.of Compliance Elec. Address.: PO Box 1698 Mattituck NY 11952 JOB SITE INFORMATION (All Information Required) Name: Demarco Pool House Address: 2015 Gabriella Ct, Mattituck, NY 11952 Cross Street: Tabor Rd Phone No.: 6316039092 Bldg.Permit#: Generator email: amarra@amparchitect.com Tax Map District: 1000 Section: 108 Block: 04 Lot: 7.53 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New gas powered generator Square Footage: Circle All That Apply: Is job ready for inspection?: ❑✓ YES [] NO 0 Rough In Final Do you need a Temp Certificate?: ❑ YES❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC A Mini Special: Comments G � :.9- oi o;; N SURVEY. OF 1 LOT 7 �\\ "EUJAH.'S LANE ESTATES, SECT. 3 \\ �� EKED OCT. 8, 1996, NO. 9913 � ' AT MATTITUCK . 1 ,�' TOWN -OF .SOUTHOLD . o `o�r. o . . ,� - SUFFOLK COUNTY .N-Y o veNA "',� '� v 1000-'108 04-7.53 SCALK 1':40.'' . : =1p JANUARY-20 2022 " 0 SGp�' o O �'y� u4�aP.'���t9• F � - �a _ - UNITS P'�GZPl��1ck 2M FLR. - WNowwEu 1 FE.COR. �c� O BALCONY n�0�• '�C I 0.3'S Y ?• 0.6'W : OAT -. 2Ul �` p. w . tio�� • - !y \��� PSG J�c � ,�,� - ' _ ;I Y C Le39.27` I FE.COR: 2.VW. i MONUMENT: " • = PIPE I ANY AL7ERAflON OR AODIAON 9618 TO THIS SURVEY IS A-WOLA770N Q� N.Y.S O� NO. 2-01 OF SEC770N-72090F THE.NEW YORK STATE EDUCA77ON LAW. �y Y.� UC N0. 051132-Of EXCEPT AS PER SEC77ON 7209-SUBDIVISION 2. ALL CER77RCA77ON8 �` PECON/C -5SURVEYORS; (63 HEREON ARE"VALID.FOR THIS MAP AND COPIES THEREOF ONLY IF y_ (631)Box 909 0 FAX(831) 765-1797- SAM MAP.OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR P.0 BOX 909. I WHOSE SIGNATURE APPEARS HEREON. AREA .= 41,164" SQ. FT 1230"7RAVEZER s71iEET SOUIHOLD. N.Y. 11971 121-088. L OfFicic., APPROVED AS NOTED DATE- o-043 B.P.# Ll a COMPLY WITH ALL CODES OF $ 50 P 60Jf NEW YORK STATE & TOWN CODES FEE: BY A NOTIFY BUILDING DEPARTMENT AT S REQUIRED AND CONDITIONS OF 765-1802 8 AM TO 4 PM FOR THE SOUTHOLD TOWNZBA FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE SOUTHOLD TOWNPIAI►INING81(01) 2. ROUGH-FRAMING,PLUMBING, STRAPPING. ELECTRICAL&CAULKING .,_.__��SOUTHOLD TOWN TRUSTEES 3. INSULATION 4 4 FINAL-CONSTRUCTION &ELECTRICAL N.Y.S. DEC MUST BE COMPLETE FOR C.O. - ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ELECTRICAL INSPECTION REQUIRED 3F Kl0Lif1+cLlA miAlrnuM 5elbac k Of 15 fec+ z ' S52°19'20"W 268.56' y rAr--------------------------- -----------------------� l7 z- 1 1 A o 0 z � I rn o rn i ----------- i U X i m p n rn f11 I Ifrn pi(�� �iOz r DZN o;�� o o o r l ��p=� z!�nrn rr I I > ' °D�cn x O N �p z N DN N rn rn i rn z u V cu z rD c �X 0 o I _0�70 I r � �, z -4l -L---------------------------------------------------J N52°19'20"E 265.00' Ilk tB 0 PROPOSAL FOR: MARK UP DATE: COMMENTS DATE: 05/08/23 DEMARCO AMP Architecture THESE PLANS ARE FOR DESIGN PURPOSES ONLY AND SHALL NOT BE USED FOR GENERATOR CONSTRUCTION.THE DESIGNS PRESENTED HEREIN ARE THE PROPERTY OF AMP ARCHITECTURE,LLC AND SHALL NOT BE DUPLICATED WITHOUT WRITTEN PAGE: AUTHORIZATION FROM ANTHONY PORTILLO,RA,LEED AP.THESE PLANS ARE 2015 GABRIELLA COURT Design + Build PROTECTED AGAINST ANY UNAUTHORIZED USE UNDER FEDERAL LAW BY THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990(AWCPA),WHICH MATTITUCK,N.Y.11952 HAS SEVERE PENALTIES. KOHLER. Models: 20RCA(L) Multi-Fuel LPG/Natural Gas 09001 Standard Features 4 KOHLER. • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT). o Electronic speed control responds quickly to varying o demand. o OnCueD Plus Generator Management System for remote i *1 monitoring is included with the generator. :., �; ��..;�..:�. • Kohler Command PRO Engine Features ..y o Kohler Command PROID OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. • Designed for Easy Installation KOifL' = o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. o Fuel and electrical connections through the enclosure wall The Kohler® Advantage eliminate the need for stub-ups through the base. o Customer connection terminal block located near the • High Quality Power controller allows easy access for field wiring. Kohler home generators provide advanced voltage and o Designed for outdoor installation only. frequency regulation along with ultra-low levels of • Certifications harmonic distortion for excellent generator power quality to protect your valuable electronics. o Meets emission regulations for U.S. Environmental Protection Agency(EPA)with both natural gas and LPG. • Extraordinary Reliability o UL 2200/cUL listed (60 Hz model). Kohler is known for extraordinary reliability and o CSA certification available (60 Hz model). performance and backs that up with a premium 5-year or o Accepted by the Massachusetts Board of Registration of 2000 hour limited warranty. Plumbers and Gas Fitters. • Powerful Performance o Meets 181 mph wind rating. Exclusive Pow§boost"" technology provides excellent starting power. Approved for stationary standby applications in locations • Aluminum Enclosure served by a reliable utility source.o Attractive aluminum enclosure allows installation as • 20RCAL models packaged with a Model RXT automatic F transfer switch are available. See page 4 and the Model close as 18 inches from your home or small business. RXT ATS specification sheet. o Enclosure panels can be removed without tools to allow • Warrant easy access for maintenance and service. y o 5-year/2000 hour limited warranty for on-grid (standby) applications in locations served by a reliable utility source. Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Alternator Voltage Phase Hz kW/kVA Amps kW/kVA Amps Amps Poles 2F7 120/240 1 60 18/18 75 20/20 83 100 2 120/208 3 60 17/21 58 17/21 58 70 3 2137 120/240 3 60 17/21 51 17/21 51 60 3 277/480 3 60 17/21 26 17/21 26 30 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS:Standby ratings apply to installations served by a reliable utility source.All single-phase units are rated at 1.0 power factor.The standby rating is applicable to variable loads with an average load factor of 80%for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO-3046/1,BS5514,AS2789,and DIN 6271.GENERAL GUIDELINES FOR DEBATING:ALTITUDE:Derate 4%per 305 in(1000 fL)elevation above 153 m(500 ft.).TEMPERATURE:Derate 2%per 5.5'C(1 O°F)temperature increase above 16'C(60'F). Availability is subject to change without notice.The generator set manufacturer reserves the rightto change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co.generator distributor for availability. § Check the appliance manufacturer's specifications for actual power requirements. Consult a Kohlerm Power Systems professional to calculate your exact residential power system requirements. Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. G4-272 (20RCA) 9/19c Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator • Compliance with NEMA, IEEE, and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole, Rotating Field a Self-ventilated and dripproof construction. Leads,quantity 2F7 4 • Windings are vacuum-impregnated with epoxy varnish for 2G7 12 dependability and long life. Voltage regulator Digital • Superior voltage waveform and minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction. Material Class H • Digital voltage regulator with±1.0% no-load to full-load Temperature rise 130°C Standby RMS regulation. Bearing:quantity,type 1,Sealed • Rotating-field alternator with static exciter for excellent Coupling Direct load response. Amortisseur windings Full . Total harmonic distortion (THD)from no load to full load with Voltage regulation,no-load to full-load RMS ±1.0% a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V,1 ph 2F7(4 lead) 41 (60 Hz) 240 or 480 V,3 ph 2G7(12 lead) 69(60 Hz) Application Data Engine Exhaust Engine Specifications Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine:model,type CHI 0004-Cycle enclosure at rated kW,dry, °C(IF) 260(500) Cylinder arrangement V-2 Lubrication Displacement,cm3(cu.in.) 999(61) Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) Lubricating System Compression ratio 8.8:1 Type Full Pressure Main bearings:quantity,type 2,Heavy-Duty Sleeve Oil capacity(with filter), L(qt.)§ 1.9(2.0) Bearings Oil filter:quantity,type§ 1,Cartridge Rated RPM Oil cooler Integral 60 Hz 3600 § Kohler recommends the use of Kohler Genuine oil and filters. Max.engine power at rated rpm,kW(HP) LPG,60 Hz 23.0(30.9) Fuel Pipe Size Natural gas,60 Hz 20.2(27.1) Cylinder head material Aluminum Minimum Gas Pipe Size Recommendation,in.NPT Valve material Steel/Stellite� Pipe Length, Natural Gas LPG m(ft.) 281,000 Btu/hr. 340,000 Btu/hr. Piston type and material Aluminum Alloy Crankshaft material Heat Treated,Ductile Iron 8 (25) 1 3/4 Governor:type Electronic 15 (50) 1 1 Frequency regulation,no load to full load Isochronous 30 (100) 1 1/4 1 Frequency regulation,steady state t0.5% 46 (150) 1 1/4 1 1/4 Air cleaner type Dry 61 (200) 11/4 11/4 Engine Electrical Engine Electrical System Ignition system Electronic, Capacitive Discharge Starter motor rated voltage(DC) 12 Battery(purchased separately): Ground Negative Volts(DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA)rating for-1BIC(0°F) 500 Group size 51 134-272 (20RCA) 9/19c Fuel Requirements RDC2 Controller Features, Continued Fuel System • LED indicators for utility power and generator set source Fuel types Natural Gas or LPG availability and ATS position (Model RXT transfer switch Fuel supply inlet 1/2 NPT required) Fuel supply pressure,kPa(in.H20): • LCD display: Natural gas 0.9-2.7(3.5-11) o Two lines x 16 characters per line LP 1.7-2.7(7-11) o Backlit display with adjustable contrast for excellent Fuel Composition Limits* Nat.Gas LPG visibility in all lighting conditions Methane,%by volume(minimum) 90 min. — • Scrolling system status display:o Generator set status Ethane,%by volume(maximum) 4.0 max. — o Voltage and frequency Propane,%by volume 1.0 max. 85 min. o Engine temperature Propene,%by volume(maximum) 0.1 max. 5.0 max. o Oil pressure C4 and higher,%by volume 0.3 max. 2.5 max. o Battery voltage Sulfur,ppm mass(maximum) 25 max. o Engine runtime hours Lower heating value, g MJ/m3(Btu/ft3), (minimum) 33.2(890) 84.2(2260) • Date and time displays * Contact your local distributor for suitability and rating derates based • Smart engine cooldown senses engine temperature on fuel compositions outside these limits. • Digital isochronous governor maintains steady-state speed at all loads Operation Requirements • Digital voltage regulation: ±1.0% RMS no-load to full-load Fuel Consumption,m3/hr.(cfh)@ 60Hz • Automatic start with programmed cranking cycle %Load Natural Gas LPG • Programmable exerciser can be set to start automatically on 100 8.0 (281) 3.9 (136) any future day and time, and run every week or every two 75 6.9 (243) 3.1 (109) weeks 50 4.6 (161) 2.3 (82) • Exercise modes: 25 3.6 (127) 1.7 (59) o Unloaded weekly exercise with complete system Exercise 2.0 (71) 1.0 (35) diagnostics Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) o Unloaded full-speed exercise LPG: 93 MJ/m3(2500 Btu/ft.3) o Loaded full-speed exercise (Model RXT ATS required) LPG conversion factors: 8.58 ft.3=1 lb. • Front-access mini USB connector for SiteTech- or USB 0.535 m3=1 kg Utility connection 36.39 ft.3 =1 gal. • Integral Ethernet connector for Kohler@ OnCue@ Plus Generator Set Sound Data • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection Model 20RCA 8 point logarithmic average sound levels are of a Model RDT transfer switch 64 dB(A) during weekly engine exercise and 69 dB(A) during • Diagnostic messages: Displays diagnostic messages for the full-speed generator diagnostics and normal operation.* engine,generator, Model RXT transfer switch, programmable All sound levels are measured at 7 meters with no load. interface module (PIM), and load management device. • Maintenance reminders * Lowest of 8 points measured around the generator. Sound levels at other points around generator may vary depending on installation • System settings: parameters. o System voltage,frequency, and phase o Voltage adjustment RDC2 Controller o Measurement system, English or metric • ATS status (Model RXT ATS required): o Source availability F�eg9e 60.0 Hz o ATS position (normal/utility or emergency/generator) o Source voltage and frequency • ATS control Model RXT ATS required): ( + 0 o Source voltage and frequency settings o Engine start time delay 0 0 o Transfer time delays o Voltage calibration The RDC2 controller provides integrated control for the o Fixed pickup and dropout settings generator set, Kohler@ Model RXT transfer switch, • Programmable Interface Module (PIM) status displays: programmable interface module (PIM), and load shed kit. o Input status (active/inactive) o Output status (active/inactive) RDC2 Controller Features • Load control menus: • Membrane keypad: o Load status o OFF,AUTO, and RUN pushbuttons o Test function o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF,AUTO,and RUN modes G4-272 (20RCA) 9/19c KOHL KOHLER® Phone 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features Automatic Transfer Switches and Accessories • Battery cables ❑ Model RDT ATS • EPA certified fuel system ❑ Model RXT ATS • Aluminum sound enclosure ❑ Model RXT ATS with combined interface/load management board • Critical silencer ❑ Load shed kit for RXT or RDT • Field-connection terminal block ❑ Power relay modules (use up to 4 relay modules for • Fuel solenoid valve and secondary regulator each load management device) • Line circuit breaker ❑ Other Kohler@ ATS • Multi-fuel system, LPG/natural gas,field-convertible 20RCAL Model Packages • Oil drain extension with shutoff valve ❑ 20RCAL with 100 amp RXT with 16-space load center and • OnCueD Plus Generator Management System NEMA 1 steel enclosure for indoor installation • Premium 5-year limited warranty ❑ 20RCAL with 200 amp service entrance-rated Model RXT • RDC2 generator set/ATS controller with combined interface/load management board and • Rodent-resistant construction corrosion-resistant NEMA 3R aluminum enclosure • Sound-deadening,flame-retardant foam per UL94, Warranty class HF-1 ❑ 5-Year Comprehensive Limited Warranty Available Options ❑ 10-Year Comprehensive Limited Warranty Approvals and Listings ❑ CSA approval Concrete Mounting Pads ❑ Concrete mounting pad,3 in.thick ❑ Concrete mounting pad, 4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120VAC ❑ Battery heater, 240VAC ❑ Cold weather package;120VAC Generator Set Dimensions and Weights ❑ Cold weather package,240VAC Generator Set Size, L x W x H: 1193 x 666 x 817 mm ❑ Emergency stop kit (47 x 26.2 x 32.2 in.) ❑ PowerSyncO Automatic Paralleling Module(APM) (single phase only; parallel two 20kW residential generator Shipping Weights: sets with the RDC2 controller) 20RCA Generator Set: 252 kg(555 lb.) Programmable interface module PIM 20RCAL with 100 A RXT ATS w/LC 277 kg(611 lbs.) ❑ 9 , ( ) 20RCAL with 200 A RXT SE ATS: 272 kg(600 lb.) (provides 2 digital inputs and 6 relay outputs) L Fuel System Accessories ❑ Flexible fuel line (included on QS models) ❑ Carburetor heater, 120 VAC ❑ Carburetor heater, 240 VAC H �' Carburetor heater is recommended for reliable starting a at temperatures below 0°C (32°F) Literature ❑ General maintenance literature kit i W ❑ Overhaul literature kit NOTE: Dimensions are provided for reference only and should not be used for planning ❑ Production literature kit installation.Contact your local distributor for more detailed information. Maintenance DISTRIBUTED BY: ❑ Maintenance kit(includes air filter, oil, oil filter,and spark plugs) ©2018,2019 by Kohler Co. All rights reserved. G4-272 (20RCA) 9/19c