Loading...
HomeMy WebLinkAbout50091-Z 1 �o�o coGy Town of Southold 1/27/2024 o P.O.Box 1179 co 53095 Main Rd S' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44904 Date: 1/27/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 55 Oriole Dr, Southold SCTM#: 473889 Sec/Block/Lot: 55.-6-15.24 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/13/2023 pursuant to which Building Permit No. 50091 dated 12/6/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Israel,Marcel&Amy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50091 1/9/2024 PLUMBERS CERTIFICATION DATED - *-6k 'y1AP AiAnrizkh Signatu ��o�guF c TOWN OF SOUTHOLD y1 BUILDING DEPARTMENT coTOWN CLERK'S OFFICE � x "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 60091 Date: 12/6/2023 Permission is hereby granted to: Israel, Marcel 685 Osprey Nest Rd Greenport, NY 11944 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 55 Oriole Dr, Southold SCTM # 473889 Sec/Block/Lot# 55.-6-15.24 Pursuant to application dated 11/13/2023 and approved by the Building Inspector. To expire on 6/612025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector o��oF so�ryQl � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.deviin(cD-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Marcel Israel Address: 55 Oriole Dr city:Southold st: NY zip: 11971 Building Permit#: 50091 section: 55 Block: 6 Lot: 15.24 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Solar X Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 24.4kW Roof Mounted PV Solar Energy System w/ (61)CSI CS6R-400W Modules, Notes: Solar Inspector Signature: Date: January 9, 2024 S.Devlin-Cert Electrical Compliance Form SO(/lyOlo - f # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ," ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR '- D q_ � �aOF SOUTyo � # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ FINAL Go/a.+,--p [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: P-04I n51 !l Aom -4et "Pit 5 0A L24 J-4-atle-111- DATE INSPECTOR �O�aOF SOpI�°!o 500 # TOWN OF SOUTHOLD BUILDING DEPT. °`ycourmN�'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR r Zoho Sign Document ID:2A768FFA-MBMIWFKBXOXCZOHXNBFR4XIY9CYLPFYSZVMWCRVKFTW 7CV; � %J ?* ,\ Town of Southold December 18th, 202 Building Department 1 6 Z024 Town Hall Annex Building 54375 Route 25 ri P.O. Box 1179 �ct4i :Kt L'E .id Southold, NY 11971 Subject: Roof Mounted Solar Panels at the Israel Residence, 55 Oriole Dr. Southold, NY 11971 To Town of Southold: I reviewed the solar energy system installation in the subject topic on December 18th, 2023. The units have been installed per the manufacturer's instructions and the construction drawings approved by the Building Department, Town of Southold, New York. The solar panel installation is in compliance with the requirements of the 2020 Building Code of New York State, the 2017 National Electric Code, SEVASCE 07-16 "Minimum Design Loads for Buildings and Other Structures", NFPA Standard 70, and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. Markings in accordance with Section 690.53 of the National Electrical Code are provided. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission, and conforms with reasonable standards of practice with the view to safeguarding life, health, property, and public welfare. Sincerely, Gennaro Anthony Giustra. P.E. of NEtV Great Eastern Services, Inc. CO 0 A GiGs0 PO Box 240 24 Harvey Rd 0 � Riverhead, NY 11901 Mobile: 631.235.0189 10344S Email: jerrygiustra@gmail.com AR�FEsS%( MELD INSPECTION REPORT DATE COMMENTS O FOUNDATION (1ST) ------------------------------------ -- OC FOUNDATION (2ND) z � o l� �y V ROUGH FRAMING& I PLUMBING — r r INSULATION PER N.Y. ((�� STATE ENERGY CODE �7 0/LfLI e�2. A'LC a �2. .c2s 4z / FINAL ok- ADDITIONAL COMMENTS of XH Elecwc Ce v_ - rn ►o O z H x d b Of n4coGy TOWN OF SOUTHOL,D -BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 of Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING; PERMIT For Office Use Only 1 1 E C E � V Eno PERMIT NO. ` Building Inspector: NOV 1 3 2023 Applications and forms must,be filled out in their entire ty:.lncoinplete .applications will not be accepted. Where the Applicant Nmat the owner,an g`.:i{„`nra"t'�'►'9eC°t rc Owner's Authorization form-(Page 2)shall be completed: `f c':r r:u;noid Date: 167q /c2 .3 OWNER(S)OF PROPERTY:- Name: MOYW Sryj SCTM# 1000- © O o - 0 1 + l) Project Address: 5 5 ©r t O I br., So IVY.7 I q71 Phone#: (p31--71 R -_�qq Email: Pe_rrr1;4S0i-C' Mailing Address: 55 ® n'©1 -b Y; U U l v Y G CONTACT PERSON: Name: L-0Iry-a-l-nu Mailing Address: � c l r-7 0 /d y� ,/ /1 m A� L)4 ,,,,,P IV LJ I 1 -9 5 Phone#: VJ �' ( [ q�.: Email: ��' �4 S om DESIGN PROFESSIONAL INFORMATION: . Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: . Name: Mailing Address: -7 4-7 O & d C(VC ,lu,C_,,-' Phone#: i—r7 q d9,r•1 p) Email: Pe_, �1 ,��� S l L L I j DESCRIPTION.OF PROPOSED CONSTRUCTION; ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: )§OtherT"4"1 f l wsh $� L, T mil. —'Will the lot be re-graded? ❑Yes2No Will excess fill be removed from premises? ❑Yes�1Vo oZ 4. LJ K %..9 S o l CL Y S� to I np' `n\Mr4c -,� aQegPIwS - -7a- a-U0 PROPERTY INI-ORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes>(No IF YES, PROVIDE A COPY. heck Box After Reading: The owner/contractor/desigri professional is responsible.for all drainage and stone water issues as provided by Chapter 236 of the Town Code. APPUCATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to:the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described,The applicant agrees to comply with all applicable laws,ordinances,building code, dousing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are . punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(prin . ame): �•(�rr�l (� D) fC/tk_,&Authorized Agent ❑Owner Signature of Applicant: C �.GL-tylQ.J /l04 kA::/ti, ®ate: 11 13 • ?-3 STATE OF NEW YORK) SS: COUNTY O UITL f-0 ) Loy- N—.7-b I being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the 0,4)14M chr (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this `� day of /V� � � 20�-3 Notary Public LOUIS J ROMEO Notary Public,.01R06 14813 of York PROPERTY OWNER AUTHORIZATION No.01 R06314813 Qualified in Suffolk November 17,20�Suffolk County Commission Expires (Where the applicant is not the owner) I, residing at 56 0 �� �► CSOV_fho do hereby authorize E) 0-)Q- LLC Uy"►7u- -6 to apply on ti my behalf to the Town of Southold Building Department for approval as described herein. Ow er's Signature Date 6-rn q __T� r''a Pr' Owner's Name 2 S�fFpj,4. rl PNYG DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o Town H nnex - 54375 Main Road - PO Box 1179 ' C* - 2023:, ;uthold, New York 11971-0959 .:_ Telephone (631) 765-1802 - FAX (631) 765-9502 CLu�� � gexst�titholdtownny.gov- sea nd(�southoldtownny.aov TiF,vrs�Qi.r c�att�o3t1. APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: E j(rAtr4 Fncemo L,LC,, Electrician's Name: 7elM)y - I License No.: �„�OJ ,/� g7 Elec. email: CojA Elec. Phone No: 1_1717 9,,l q q3 ICI request an email copy of Certificat6 of Compliance Elec. Address.: r/ LJ VV M +)' I q 5 JOB SITE INFORMATION (All Information Required) Name: woc-1 r Address: S n'ry ( SO ha 7 / Cross Street: -i40 1 �, t Phone No.: 1,928_2 c 13 Bldg.Permit #: -Jcpq I email: -Pe�jrl cazWLOM'd Tax Map District: 1000 Section: d S;5 .00 Block: 0 , c)o Lot:®i 5. oZ BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for ihspection?: ❑ YES [%;�J NO -]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES [9fi10 Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underg round❑Overhead # Underground Laterals 2 1 2 ' H Frame Pole Work done on Service? Y N Additional Information: L(, y K-W tclu�� Rrv� �- ►��� gc�ta,F'' syS '0 �. -`'I�� - ILi o at,-t5 � I _ E►� h n-s� - 1. � g P l use 7a.�a - v�.s - 1 V�v�v`�� PAYMENT DUE WITH APPLICATION YaSTATm workers' CERTIFICATE OF INSURANCE COVERAGE E Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that came la.Legal Name 8 Address of Insured(use street address only) 1 b.Business Telephone Number of insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured Work Location of Insured(anlyr8y+,leelfcoverage is specrAtallylimded to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 823336604 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"la' SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/0112023 to 12/31/2024 4. Policy provides the following benefits: ® &Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers. ® A.All of fhe employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. 0 B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By �",&f (Signature of insurance carriers aud+orized representative or NYS Ucensed Insurance Agent of that insurance carfier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only If Box 46,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance poCcies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-f 20.f.Insurance brokers are NOT authorized to Issue this form. DB-120.1 (12-21) 11'��rI�I�����ii�irii A0 RI'® CERTIFICATE OF LIABILITY INSURANCE DATE IM 7M 11 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endomement(s). PRODUCER CONTACT ROBERT S.FEDE INSURANCE AGENCY NAME: PHONE - FAX 23 GREEN STREET,SUITE 102 NO Ext- AIC N°' E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSURERS)AFFORDING COVERAGE NAIL s INSURER A:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURER B_.STATE INSURANCE FUND 52393C . Element Energy LLC INSURER c. DBA ELEMENT ENERGY SYSTEMS rHsuFMxD:GENERAL STAR MANAGEMENT CO. 7470 SOUND AVENUE a1sIIItmE. MATTITUCK,NY 11952 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILNTSRR TYPE OF INSURANCE POLICY NUMBER MMroD�EFF POLICY EXP COMMERCULLGENERALLIABILn'Y L1480036873 m EACH OCCURRENCE 3 3,aoa,aaa AX X 7/14/2023 7/14=4 CLAIMS-MADE PC']OCCUR PREMISES F20009T nce 3 100,000 IVIED EXP(A one peisan $ 5000 X Contractual Lia {AAA3892036 7119/2022 7/19/2024 PERSONAL a ADV INJURY 3 3000000 GEML AGGREGATE LIMITAPPLIESPER: GENERAL AGGREGATE 3 3.000,000 PRO- POLICY JECT )( LOG PRODUCTS-COMPOOPAGG 3 woo OTHER: 1 3 AUTOMOBILELAYIBLITY COMBINEDISWGLELIMIT(Ea acci*r : ANY AUTO eO01LY INJURY(Per person) 3 OWNED SCHEDULED BODILY INJURY Per amident 3 AUTOS ONLY AUTOS ( ) HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY Per dCitlenl $ s UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS U AB Ld CLAIMS-MADE AGGREGATE $ ❑ED I I RETENnCNS $ WORKERS COMPENSATIONAND EMPLOYERS*LIABILITY 124494445 PER oTH- ANY PROPPRIETOMPARTNEP"r-CUTAIE YIN 7/1 M023 7/13/2024 a ER B OFFICERINEMBER EXCLUDED? NIA EL EACH ACCIDENT $ 1,000,000 IMandat°ry In NH) EL DISEASE-FA EMPLOYEE $ I1 yes,,desodbe UNW DESCPoPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT 3 NY State DBL DBL5575ZT 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES fACORD 101,AddMonal Remarks$dwdWe,any be atteeeed If more space is reWwd) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtficate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORI7.ED REPRESENTATIVE 1?67> tS- Feces ©1988-2015 ACORD CORPORATION. A8 rights reserved. Ar,nun yc nn•IAmax Tl,n Arson.......,...i I....�... ..:a... ,,.....�. _S Arnnn /vm:�N NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 j nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) A A A A A A 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 0 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07/13/2023 TO 07/13/2024 7/11/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLiCYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/IWWW.NYSIF.COMICERTICERTVALASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU CE FUND DIRECTOR,INSURANCE FUND UNDERWRITING Zoho Sign Document ID:2A768FFA-M8Y_18WA7CQVR2DLKFCPS000AVNYMQ9WTXTZI4RCXWC 56 ©� SOLAR ARRAY ON MAIN HOUSE 24.4 kW (G I)CANADIAN SOLAR G56R-400 400 WATT PV MODULES J Z DESIGN A DRAFTING BY: (4)STRINGS OF(1 3)MICRO-INVERTERS(1)STRING OF(9)MICRO-INVERTERS ` S -t ELEMENT ENERGY LLC (5)STRINGS TOTAL SOLAR MODULE TYPICAL REVIEW BY J.M.NABCEP CERTIFIE TO UTILITY GRID % I 05) 1 1 2-1 29 STRINGS #1 -4 _ _ _ _ _ _ _ _ _ DEC 2 0 2023 - - - ENPHASE REVISIONS r- ---------------- _ BRANCH N DESCRIPTION DATE I REV I TERMINATOR BI-DIPECTIONAL - - TYPICAL o I - ------------------- UTILITY METER __- PHASE.240 V ;; , ORIGINAL I I O 20231 I 1 N MICRO-INVERTER POINT OF INTERCONNECTION I ENPHA5E IQ5PLUS-72-2-1-15 PER NEC 240.21(13)(I)6 G90.G4(A) STRING #5 240 VAC. 1.21 A LENGTH OF TAP CONDUCTORS 97%CEC-WEIGHTED EFF. SHALL NOT EXCEED I0 FT NEMA G.UL LISTED I I - _- -- -- TYPICAL I I -- - MAIN SERVICE DISCONNECT ---- 240 V.zoo A N RACTOR I ENPNASE BRANCH ELEMENT ENERGY, LLC. CIRCUIT CABLE TYPICAL5 I 1 7470 SOUND AVE MATTITUCK, NY 1 1952 AC LOAD CENTER ✓ LICENSE # G74G I-HI 240 VAC,100 A NEMA 3R.UL L15TED LICENSE # 52G(59-ME 'MTH 100 A MAIN CIRCUIT BREAKER A5 THE MAIN AC DISCONNECT MEAN5 FOR PV 5Y51EM N L -1 N L L 1 (5)20 A DOUBLE POLE 5REAUK5 (I)15 A DOUBLE POLE BREAKER {- 0 A 20 A GATEWAY FOR COMMUNICATION DEVICE (Q iNG rl � isA MAIN SERVICE PANEL I la - - - - ----J I-PH.3-W n I W 1 __------------------------------------------ 240 VAC m Z N N i+ I I I �O �034 IG 4'' � oo i I - -i ARQ SSIoNP\ I I EXISTING GROUNDING G N 1 I -----------� j ELECTRODE SYSTEM PROJECT NAME O LU LLJ U > (\ w z I LLJ - � - I LLJ L------------------------------------- -------------� g w J z WIRE CONDUIT SCHEDULE p D/ O u� ,// CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage ^ Drop(% E) -[ 1./ Q I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY IN5ULATION (CU/AL) TYPE SIZE TEMP DERATE DISTANCE LL-I = 310.15(D)(3) 310.15(B)(2a)/(3c) O O I INVERTERS AC LOAD CENTER AWG#8 1 10 0.5 U5E-2/PV Wire AWG#8 I BARE CU FREE AIR 1-1/4" 559C 0.84 100 FT 1.5 1% D 2 AC LOAD CENTER LINE SIDE TAP AWG#2 1 3 1 THWN-2 AWG#8 OR EMT rJLn O 1 THWN-2 CU PVC 1-1/4" 459C 0.95 100 FT I.G9% �-) ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acit Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 909C WET ENVIRONMENT. [NEC G90.8(B)(I)I:(Isc)'(#of5trm s' l.5G) = 19.GG A 3-LINE D I A. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 9 ) ( Modules per String 13 MAX. TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. AWG#8,amp'GG A Temp oreDer A = 23.I A 23.I A> 19.GG A, therefore AC were size 1s valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters G I COMPLY WITH NEC 110.2G. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL Inverter Max Amperage output'(1.25) = 92.2G A Record low temp -L 09C FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACE550PIE5 TO FULFILL AWG#2,ampacity'(Temp Derate)'(Conduit Fill Derate)= 123.5 A Voc Temp Coefficient -0.2407o/QC DRAWING SCALE APPLICABLE CODES AND STANDARDS. 123.5 A> 92.2G A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, Operatinq Current 13.0 A N .T.S. THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. O eratin Volta e 30.8 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Max.System Voltage 40.1 V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 17. A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEER LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR ILSCO GBL-4DBT LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5itive/negative) Max AC Output Current 92.2G A PV-5 OR Operating AC Volta e 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000-055.00-OG.00-0 1 5.024 Zoho Sign Document ID:2A768FFA-M8Y_18WA7CQVR2DLKFCPS000AVNYMQ9WTXTZI4RCXWC SOLAR ARRAY ON MAIN HOUSE 24.4 kW (G 1)CANADIAN SOLAR C5GR-400 400 WATT PV MODULES DESIGN a DRAFTING BY: (4)STRINGS OF(1 3)MICRO-INVERTER5(1)STRING OF(9)MICRO-INVERTERS ELEMENT ENERGY LLC -(5)STRINGS TOTAL OLAR MODULE TYPICAL REVIEW BY J.M.NABCEP CERTIFIE TO UTILITY GRID 051 1 12-1 29 STRINGS #1 -4 _ _ _ REVISIONS ENPHAE 1 N DESCRIPTION DATE REV r_ ________________ ,_BRANCH BRANCH - TERMIINATOR _ BI DIRECTIONAL ORIGINAL I I-10-2023 ITYPICALI � UTILITY METER t- ------------------- ---' -- ---' -- -- -- -- -- -- ---' I-PHASE.240 V MICRO-INVERTER I EN PHASE IOTU5-72-2-US PEP N POINT OFINTERCONNECTION 0.2CB)(N)CS 90.G4(A) I 240 VAC, I.2 1 A --LENGTH OF TAP CON DUC ORS STRING #5 _ _ _ _ - - - - - 97%CEC-WEIGHTED EFF. SHALL NOT EXCEED 10 FT I - - - NEMA G.UL LISTED I - -- - TYPICAL I I � M I I - ------ - _ I --_- --- - MAIN SERVICE DISCONNECT 240v.200A CONTRACTOR - ENPHA5E BRANCH ELEMENT ENERGY, LLC. CIRCUIT CABLE TYPICAL 7470 SOUND AVE 1 MATTITUCK, NY 1 1952 AC LOAD CENTER LICENSE # G74G I-HI 240 VAC.100 A NEMA 3R.VL 1.15TED LICENSE# 52G89-ME IMTH 100 A MAIN CIRCUIT 6REAKER rr�1 A.5 THE R PV MNN A DISCONNECT MEAN5 FO ' 1 v) N L _1 N L L I (5)20 A DOUBLE POLE 5REAKER5 T (1)15 A DOUBLE POLE BREAKER �IC{^, 0 A 20 A GATEWAY FOR COMMUNICATION DEVICE !OF I V L W V +^ �P�4�0 A V�� I 1 1 � is A MAIN SERVICE PANEL I-PH.3-W 0 • 1 U 240 VAC Z � ---- � 200A �f1 �� Vi I I N �O 70344'' G - -i I �OFESS1 °° I I EXISTING GROUNDING G N 1 I �___________J j ELECTRODE SYSTEM 1 I PROJECT NAME 0 lLJ U-J - I I � > m I ' W z E - I LLJ p - I E LLJ L------------------------------------- ------------- _� 'Liz WIRE CONDUIT SCHEDULE 0 � O CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% C) J L //L_ O I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE DISTANCE N LLl = 310.15(5)(3) 310.15(5)(2ay(3c) O O I INVERTERS AC LOAD CENTER AWG#8 1 10 0.5 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR 1-114" 559C 0.54 100 FT 1.5 1% 15-O D OR EMT O 2 AC LOAD CENTER LINE SIDE TAP AWG#2 I 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 1-114" 45QC 0.95 100 FT I.G9% - Ln ((� ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acit Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. P y 3-LINE D I A. 3.)WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY [NEC G90.8(achy:(Te '(#of strmgs)'(I.5G)= 19.GG A Modules per String 13 MAX. TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. AWG#8,amp.GG A Temp oreDer A = 23.I A 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 23.I A> 19.GG A,therefore AC wire size is valid. Modules per Inverter I COMPLY WITH NEC 110.2G. #2 Inverter OutputP y Wire Am acit Calculation Number of Inverters GI 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL Inverter Max Amperage output' (1.25)= 92.2G A Record low temp -I OQC FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE550RIE5 TO FULFILL AWG#2,ampacity'(femp Derate)'(Conduit Fill Derate) = 123.5 A Voc Temp Coefficient -0.247./2C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 123.5 A> 92.2G A, therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, O eratin Current 13.0 A I T THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. I `I f 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. Operatinq Voltacle 30.8 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Max.System Voltage 40.1 V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 17.3 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR IL5CO G5L-4DBT LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) Max AC Output Current 92.2E A PV-5 OR O eratin AC Volta e 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000-055.00-OG.00-0 15.024 Zoho Sign Document ID:2A768FFA-M8Y_18WA7CQVR2DLKFCPS000AVNYMQ9WTXTZI4RCXWC SOLAR ARRAY ON MAIN HOUSE 24.4 kW (G 1)CANADIAN SOLAR C5GP.-400 400 WATT PV MODULES DESIGN$DRAFTING BY: (4)STRINGS OF(1 3)MICRO-INVERTERS(1)STRING OF(9)MICRO-INVERTERS ELEMENT ENERGY LLC '(5)STRINGS TOTAL OLAR MODULE TYPICAL REVIEW BY J.M.NABCEP CERTIFIE TO UTILITY GRID 05 I 1 1 2-129 STRINGS #1 -4 REVISIONS _ _ _ _ _ _ �1.. _ _ _ � _ _ ENPHASE BRANCH N DESCRIPTION DATE j REV 1 TERMINATORR I N L ORIGINAL 11-lo_ _2023 TYPICAL UTILITY METER �- ------------------- I-PHASE.240 V 1 I MICRO-INVERTER 1 N I POINT OF INTERCONNECTION 1 ENPHASE IQ8PLU5-72-2-U5 PER NEC 240.21(5)(1)$G90.G4(A) I 240 CAC-WEIGHTED EFF. LENGTH OF TAP CONDUCTORS STRING #5 SHALL NOT EXCEED 10 FT I NEMA G.UL LISTED TYPICAL N I I MAIN SERVICE DISCONNECT CONTRACTOR 240 V.200 AENPHA5E BRANCH ELEMENT ENERGY, LLC. CIRCUIT CABLE TYPICAL 7470 SOUND'AVE 1 MATTITUCK, NY 1 1952 1 AC LOAD CENTER LICENSE # G74G 1-111 240 VAC,100 A NEMA 3R.UL 1-15TED LICENSE# 52G59-ME 1 WITH 100 A MAIN ORCUIT BREM.ER AS THE MAIN AC D15CONWECr MEANS FOR PV 5Y5TEM kO N L L I (1)20 A DOUBLE POLE BREAKERS Q r IN�� (I)15 A DOUBLE POLE BREAKER r 20 A GATEWAY FOR COMMUNICATION DEVICE ! ^G N L I O A G015 AMAIN SERVICE PANEL- - -- Lu Ul _--------------------------------------------- I 200 AAC I N �O 703443 I 1 i G 1 I A OFESSIONP� 00 I I EXISTING GROUNDING G N 1 I I I I ELECTRODE SYSTEM I -----------j I PROJECT NAME I i - O U-j LU _ I I LL. U _> LU z I 1-- lLJ - r Q I , LLB z ------------------------------------- ------------- 0 � WIRE CONDUIT SCHEDULE W� 0^/ CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% C) J Q I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION 51ZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE DISTANCE (j LU = 310.15[5)(3) 310.15(5)(2a)I(3c) O O I INVERTERS AC LOAD CENTER AWG#8 1 10 0.5 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR 1-114" 559C 0.84 100 FT 1.5 1% 0-- D OR EMT 0 Q 2 AC LOAD CENTER LINE SIDE TAP AWG#2 I 3 I THWN-2 AWG#8 I THWN-2 CU PVC 1-114" 459C 0.95 100 IT I.G9% - Ln (f) ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acit Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 904C WET ENVIRONMENT. (NEC G90.8(B)(I)I:(Isc)'(#of5trin 5)'(I.5G)= 19.GG A 3-LINE D I A. 3.)WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY g Modules per String 13 MAX. TO,AND LOCATED AS CLOSE AS P0551BLE TO THE NEAREST RIDGE, HIP, OR VALLEY. AWG#8,amp GG 'Temp oreDer A = 23.I A 23.I A> 19.GG A, therefore AC wire size is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters GI COMPLY WITH NEC 1 10.2G. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 92.2G A Record low temp -109C FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACES50RIE5 TO FULFILL AWG#2,ampacity'(Temp Derate)'(Conduit Fill Derate)= 123.5 A Voc Temp Coefficient -0.2407o/QC DRAWING SCALE APPLICABLE CODES AND STANDARDS. 123.5 A> 92.2G A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. O eratin Current 13.0 A N .T.5. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. O eratin Volta e 30.8 V 5.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Max.System Voltage 40.1 V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. Short Circuit Current 17.3 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEER LUG AC 5Y5TEM SPECIFICATIONS SHEET NUMBER OR IL5CO GBL-4DBT LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) Max AC Output Current 92.2G A PV-5 OR O eratin AC Volta e 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000-055.00-OG.00-0 15.024 Zoho Sign Document ID:2A768FFA-M8Y-18WA7CQVR2DLKFCPS000AVNYMQ9WTXTZI4RCXWC 50IAP ARRAY ON MAIN HOUSE 24.4 kW (G 1)CANADIAN SOLAR C5GR-400 400 WATT PV MODULES DESIGN l,DRAFTING BY: (4)STRINGS OF(1 3)MICRO-INVERTERS(1)STRING OF(9)MICRO-INVERTERS ELEMENT ENERGY LLC '(5)STRINGS TOTAL OLAP MODULE TYPICAL REVIEW BY J.M.NABCEP CERTIFIE TO UTILITY GRID 05 1 1 1 2-1 29 STRINGS #1 -4 REVISIONS ENPHA5E 1 N DESCRIPTION I DATE REV r---------------------- BRANCH NAL - ------------------- TTYPICA ATOR O I-PHASE.OO V ORIGINAL I -10-20231 - -- -- UTILITY METER j 1 N MICRO-INVERTER POINT OF INTERCONNECTION I ENPHA5E IQ5PLUS-72-2-U5 PER NEC 240.21(5)(1)s G90.G4(A) STRING #5 240 VAC, 1.21 A N OF TAP CONDUCTORS 97%CEC-WEIGHTED EFF. 5,A-SF1ALL NOT EXCEED I OFT I NEMA G.UL L15TED TYPICAL I I - ------- - MAIN 5ERVICE D15CONNECT CONTRACTOR ENPHA5E BRAN CH ELEMENT ENERGY, LLC. CIRCUIT CABLE TYPICAL 7470 SOUND WE 1 MATTITUCK, NY 1 195 AC LOAD CENTER LICENSE # G74G I-HI 240 VAC,100 A NEMA 3R.UL L15TED LICENSE # 52G89-ME WITH I OD A MAN CIRCUIT BREAKER As THE MAIN AC D15CONIJECT MEAN5 FOR W SY5TEM 1 1 N L -1 N L -1 (5)20 A DOUBLE POLE BREAKERS (I)15 A DOU31E POLE BREACEK !, r Q FOR COMMUNICATION DEVICE -or G 0 °A 20 A NE GATEWAY �4'�YO A {�* * - - G N L2 L I 1 � ISA MAIN SERVICE PANELLu I-PH,3-W 240 VAC 1 - -- - 200 A �03443 <G� G I - - A�Q SSIONP� I I I 1 Ioo 1 I I EXISTING GROUNDING I 1 I ELECTRODE SYSTEM G N 7 -----------J PROJECT NAME O U > (\ w lZ } C I LLJ L------------------------------------- -------------J g � z LL_ WIRE CONDUIT SCHEDULE O ,Q// CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% J Q I.D.# ORIGIN DESTINATION 51ZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE DISTANCE Lj LL O = 310.15(5)(3) . 310.15(5)(2ay(3c) (D Q I INVERTERS AC LOAD CENTER AWG#8 1 10 0.5 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR 1-1/4" 55QC 0.84 100 FT 1.5 1% Ln D OR EMT n O 2 AC LOAD CENTER LINE SIDE TAP AWG#2 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 1-114" 459C 0.95 100 IT I.G9% n - Ln ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acit Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 909C WET ENVIRONMENT. [NEC G90.8(B)(I)]:(Isc)'(#ofstnn s)'(I.5G)= 19.GG A 3-LINE D I A. 3.)WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 9 Modules per String 13 MAX. TO,AND LOCATED AS CL05E AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. AWG#A ampa G A Temp oreDer A = 23.I A 23.I A> 19.GG A, therefore AC wire size is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters G I COMPLY WITH NEC I 1 0.2G. #2 Inverter Output Wire Ampaclty Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 92.2E A Record low temp -109C FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE550RIE5 TO FULFILL AWG#2,ampacity'(Temp Derate)'(Conduit Fill Derate) = 123.5 A Voc Temp Coefficient -0.24%/9-C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 123.5 A> 92.2G A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. O eratin Current 13.0 A N T.5. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. Operatinq Voltacle 30.8 V 5.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Max.System Voltage 40.I V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. Short Circuit Current 17. A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR I1-5CO G5L-4DBT LAY-IN LUG. Max AC Output Current 92.2G A 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(positive/negative) PV-5 OR O eratin AC Volta e 240 V 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000-055.00-OG.00-0 1 5.024 Zoho Sign Document ID:2A768FFA-M8Y_18WA7CQVR2DLKFCPS000AVNYMQ9WTXTZI4RCXWC Town of Southold November 10th, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Israel Residence, 55 Oriole Dr. Southold. NY 11971 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 3.0 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. ��oF NEWY Great Eastern Services, Inc. o A c0 PO Box 240 = 24 Harvey Rd t•�. 'd� W Riverhead, NY 11901 Mobile: 631.235.0189 O 103443 Email: jerrygiustra@gmaii.com ARo�sstio�'��" Zoho Sigri Document ID:2A768FFA-M8Y_18WA7CQVR2DLKFCPS000AVNYMQ9WTXTZI4RCXWC SCOT E O F WORK _ _ E N 4 DRAFTING BY: r l:a5l hta rr on` ENT ENERGY LLC TO INSTALL A 24.4 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT ISRAEL RESIDENCE, 1 1etFond J.M.NABCEP CERTIFIE I;iuniy Park 051112-129 LOCATED AT 55 ORIOLE DR,SOUTHOLD, NY 1 1 971. w. onye�en THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH ®�`�` Dare,'yn,ho se9 THE EXISTING ELECTRICAL SERVICE EQUIPMENT. ® tre�rryon Squad wew Greenport-� REVISIONS DESCRIPTION DATE REV Denng Harbor —1l ORIGINAL 11-10-2023 ul.Ca"Mustlpr., SYSTEM RATING Na %- ,,,�,,,� �° ,T F,an Ld.. ,�.. PIA 24.4 kW DC 5TC !�' Southold - : `,P SheRerlslar>o r EQUIPMENT SUMMARY �� ` °�=�J-h� `�` G I CANADIAN SOLAR C5GR-400 400 WATT PV MODULES G I ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS r F CONTRACTOR I IRONRIDGE XRI 00 MOUNTING SYSTEM ELEMENT ENERGY, LLC. SHEET INDEX ` `� 0 7470 SOUND AVE PV-I COVER MATTITUCK, NY 1 1952 PV-2 517E PLAN PROJECT LOCATION LICENSE# G74G I-HI PV-3 ROOF PV LAYOUT LICENSE# 52G89-ME PV-4 STRUCTURAL/DETAILS 6 5ECTION5 PV-5 3-LINE ELECTRICAL DIAGRAM + PV-G LABELS Oir IMER, GOVERNING CODES '!=k: �: f�= ,,� �'�Pa�`O A 2017 NATIONAL ELECTRICAL CODE. 2020 RESIDENTIAL CODE OF NEW YORK STATE. ` E- p U 2020 FIRE CODE OF NEW YORK STATE. , A5CE 7-1 G AND NFPA-70. w� n EL,EC�TwRICA�Ly n �-,=��: � � N OSHA UNDEPWPITEP5 1910.2G9 A 0RIE5(UL)STANDARDS INSPECTION REQUIRED .+ a. �A 10344'' GENERAL NOTES ' F 1 PROJECT NAME I. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT '�-` `'� �1 p W LL_1 THE 51TE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE R4 U U _> HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK w Z �/ AGREE THE SAME. AERIAL VIEW N LLJ Q — 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL E ORK STATE ODES 0 In J z INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. CONTRACTOR'S LIABILITY, WORKMAN5 COMPENSATION, CE COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES QUIRED AND CONDITI E 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND AP, OV& AS NOTED OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO SOUTHOLD TOW ALL RULES AND REGULATIONS OF THE RESPONSIBLE A > £. o J 0 COMMENCING WITH WORK. _ = .__ •� w 1 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR DATE: z -P# �b� O JURISDICTION. W = 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE --_ -- '` SOUTHOLD N PLANNIt G Af� WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS �^ r` THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE FEE TOWN TRUSTS S 00 AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT NOTIFY SUI—10 DEPARTMEN AT N , ,DEG CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, 631-765t1002,I3AM.TO 4PM FOR THE OUTHOLD HPC RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SHEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE FOLLOWING aNSPECTIONS: pp FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT 1. FOUNDATION-TVVO REQUIRED SCHD COVER CONSTRUCTION. SPECIFICATIONS. 1 2. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE FOR POUREu C ONCRETE UNDERWRITERS APPROVED AND IN G. ALL ELECTRICAL WORK SHALL N BOARD OF FIRE ACCORDANCE WITH N.E.C. t DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING 2. ROUGH-FRAMING&PLUMBING �• �. CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES s REGULATIONS 3. INSULATION OCCUPANCY Ott 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND 4. FINAL-CONSTRUCTION MUST COMMENCING WITH WORK.CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS BE COMPLETE FOR C.O. USE IS UNLAWFUL DRAWING SCALE CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON ALL CONSTRUCTION SHALL MEET THE I N ,T.5 8. THESE DRAWINGS AS INSTRUCME WITHOUT NT5 OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. CERTIFICA- SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED REQUIREMENTS-OF THE CODES OF NEVI! PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE YORK STATE"-NOT RESPONSIBLE FOR OF OCCUPANCY THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE DESIGN OR CONSTRUCTON ERRORS SHEET NUMBER EXTENSIONS TO THIS PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. EXISTING WORK ADJACENT TO HI5 WORK, OR DAMAGED AS I p V- RESULT OF HIS WORK. TAX MAP: 1000-055.00-OG.00-0 15.024 ,Zoho Sign Document ID:2A768FFA-M8Y_18WA7CQVR2DLKFCPSQOUAVNYMQ9WTXTZI4RCXWC LEGEND TAX MAP: 1 000-055.00-OG.00-01 5.024 DESIGN&DRAFTING BY: EMS ® MAIN SE UTILITY METER ELEMREVIEW BY EM.NABCEP CERTIFIE MAIN SERVICE PANEL 051 1 1 2-1 29 NEW PV SUB-PANELS A/C DISCONNECT COMBINER INVERTERS IN GND ELECTRODE REVISIONS PV MODULEDE5CRIPTION DATE REV ORIGINAL I1-10-2023 RACKING RAIL O ATTACHMENT POINT /➢/ ---RAFTERS FROOF PITCH ANGLE BSUNRUN METER ACCESS ROOF OVENT PLUMBING VENT / ®SKY LIGHT // j/ 8° IRE SETBACK,@RIDGE/ CONTRACTOR ®CHIMNEY 5ETBACK @RIDGE ®COMPOSITE SHINGLES - ELEMENT ENERGY, LLC. GOOD CONDITION 18°FIRE SETBACK @R1DGE� 18°FIRE 5 / C / EDGE ❑POTENTIAL SHADING ISSUES ACCE5s oo 7470 SOUND AVE TRIM/REMOVE AS NECESSARY / // MATTITUCK, NY 1 1952 I LICENSE#G74G I-HI 4 24 42 / LICENSE# 52G89-ME of NE14,, / �P�pgo A G�G O,p ® J r 103445 1 � Ro�ss►oNP�' •N N ;�. n;n PROJECT NAME 27-G" w w — n n O,rn \ n. 3!;� N L z � � — w / / C / to L z 0 0LLJ 0 >� / % O IL ��/ j� 18'-I I" LL O /n n 24'-9"1 j 2 /7 5NEET NAME / FIRE SETBACK @RIDGES L�� A' 51 TE PLAN 'NOTE 0511, Q'v 1.)THE ROOF SETBACK/PATHWAY SHALL NOT 5E /- REQUIRED ON ROOF SLOPE WHERE THE , DRAWING SCALE ADJACENT OR OPPOSITE ROOF SLOPE 15 THE ��� �m 1(51- 1 1 II 270 4 ACCESS ROOF IN ACCORDANCE WITH R324.G.I j % j � I/QII I I_OII EXCEPTION OF 2020 NYS RESIDENTIAL CODE. / j �� 240° CONSTRUCTION NOTES /"� %" 210° D 12p° 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 180°1g0° 511EET NUMBER ALL INSTALLATION H INSTRUCTIONS.O T R DOO EQU PMENS E ALL RA NTI 2.)A G T WITH MINIMUM NEMA 3P.RATING. j j S I V -2 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. j ?oho Sign'Document ID:2A768FFA-M8Y_18WA7CQVR2DLKFCPSQOUAVNYMQ9WTXTZI4RCXWC CONSTRUCTION SUMMARY TAX MAP: 1000-055.00-0G.00-01 5.024 DESIGN i DRAFTING BY: (G 1) QCELL Q.PEAK DUO BLK ML-G 1 0+ 405 WATT PV MODULES j j ELEMENT ENERGY LLC (DIMENSIONS: 74"X 4 1.1"X 1.3") �V A� REVIEW BY J.M.NABCEP CERTIFIE (GI) ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS 051112-125 (148)ATTACHMENT POINTS @ G4"O.C. MAX. p° (510.7) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. 14" In, REVISIONS ROOF TYPE: ASPHALT(SINGLE LAYER) /° /° 2�p 4 ' DE5CR)FTION DATE REV CONSTRUCTION NOTES (STING MAIN ELECTRICAL SERVICE PANEL / N j /N 240° OR GINAL 1 1-10-2023 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE n j �/ RRAY#I D 90°c WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. �/ �� 18 MODULES ?lp°2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH ® nj /p 5°PITCH 18 p°1$p°12 ° p MINIMUM NEMA 3R RATING. N 32°AZIMUTH 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE ® ACCESS ROOF S FIELD VERIFICATION. EXISTING UTILITY METER / j NEW PV AC DISCONNECT / // B°°iRe SEieA K @wDGE // // I''=IRE SETB CK@RIDGE// CONTRACTOR �� /18"FIRE SETBAC IDGE / ACCESS ROOF j ELEMENT ENERGY, LLC. 7470 SOUND AVE MATTITUCK, NY 1 1952 LICENSE# G74G I-HI O` LICENSE# 52G89-ME OF NEW y 7311 411 �P 4goA �,Gop 4 O r _ ARRAY#3 I I " ARRAY#2 �_ ;K—. G MODULES 4 1 1 MODULES �. �A 0344 45° PITCH 17°PITCH N � BRAY#5 R�FESs►oNP� 1 52'AZIMUTH 1 52°AZIMUTH ➢ D 3 MODULES Z` Z` 45' PITCH PROJECT NAME v/ ARRAY#4 'n "n G2°AZIMUTH W W — 4 MODULES N UNlul O 45°PITCH ; ; z 242°AZIMUTH � IW N Q j j g W z OO / w _ n MODULES---, /X/ S NG LEGEND p Ln O 7 ODU /N/ / �EXI TI UTILITY m= 45°PITCH MAIN LVICE PANEL — 332 AZIMUTH / NEW PV SUB-PANELS - j A/C T DISCONNECT COMBINER SHEET NAME INVERTERS GND ELECTRODE PV MODULE PV LAYOUT —RACKING RAIL ARRAY#7 o ATTACHMENT POINT 12 MODULES ---RAFTERs 45°PITCH DRAWING SCALE 152 AZIMUTH /�/' An, FRODF PITCH ANGLE jn/ /cDi ®SUNRUN METER I QIT = I 1-011 n n � ®SIT 'NOTE / / /= 0PLUMBING VENT 1.)THE ROOF SETBACK/PATHWAY SHALL NOT BE j/ / SKY uair / REQUIRED ON ROOF SLOPE WHERE THE SHEET NUMBER ADJACENT OR OPPOSITE ROOF SLOPE IS THE j CHIMj COMPOSISITE SHINGLES PV-3 ACCESS ROOF IN ACCORDANCE WITH R324.G.I / GOOD CONDITION EXCEPTION OF 2020 NYS RESIDENTIAL CODE. I'�POTENTIAL SHADING ISSUES E TRIM/REMOVE AS NECESSAR Zoho Sign'Document ID:2A768FFA-M8Y_18WA7CQVR2DLKFCPSQOUAVNYMQ9WTXTZI4RCXWC ITEM DESCRIPTION ARRAYS#1, 3, G $7 ARRAY#2 ARRAYS#4 t-5 DESIGN 4 DRAFTING BY: LOAD CALCULATION ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 ARRAY#5 ARRAY#G ARRAY#7 RB Pjcicic Beam/Boarcl 2"X 8" D. FIR 2"X 8" D. FIR 2"X 6"D. FIR ELEMENT ENERGY LLC MODULE WEIGHT(Lbs) R Rafter 2"X G" D. FIR I G"O.C. 2"X 8" D. FIR I G"O.C. 2"X G"D. FIR 1 G"O.C. REVIEW BY J.M.NABCEP CERTIFIE 484 484 484 484 484 484 454. . . . . . . (D) Dec kin 5/8"PLYWOOD 5/8"PLYWOOD 5/8" PLYWOOD 051 1 1 2-1 29 #OF MODULES 15 I I G 4 3 7 12 (J) Ceilinci Joist 2"X G" D. FIR I G"O.C. 2"X G" D. FIR I G"O.C. 2"X G"D. FIR P I G"O.C. (C) Collar Ties 2"X 4" D FIR I G"O.C. A 2"X 4"D FIR I G"O.C. EVISIONS TOTAL MODULE WEIGHT(Lbs) 571.2 532.4 290.4 193.G 145.2 338.8 580.8 D. . D. . DESCRIPTION DATE REV K Knee Walls 2"X 4" D. FIR I G"O.C. A 2"X 4"D. FIR C@ I G"O.C. TOTAL LENGTH OF RAIL(Ft) 157.7 7G.3 41.G 27.7 37.3 6G.9 83.2 (H) Horizontal 5 an of(R to MAX. 138"MAX. GG"MAX. ORIGINAL 0-2023 RAIL WEIGHT PER FOOT(Lbs) O.G8 O.GB O.G8 O.G8 O.GB O.GB O.GB TOTAL RAIL WEIGHT(Lbs) 107.2 51.0 25.3 18.8 25.4 59.1 5G.G #OF STRANDOFFS 38 20 18 8 10 22 32 WEIGHT PER STRANDOFF(Lbs) 2 2 2 2 1 2 2 2 TOTAL STANDOFF WEIGHT(UI 7G 40 3G 1 G 20 44 G4 TOTAL ARRAY WEIGHT(Lbs) 1054.4 G24.3 354.7 225.4 190.G 441.9 701.4 r� m IQ POINT LOAD(Lbs) 27.7 31.2 19.7 28.9 )9.1 20.1 21.0 r CONTRACTOR TOTAL ARRAY AREA(Sq Ft) 355.4 235.5 126.5 85.G G4.2 140.9 25G.9 w ee ELEMENT ENERGY, LLC. L L11 7470 50UND AVE ARRAY DEAD LOAD(Lbs/Sq Ft) 2.7 2.7 2.e 1 2.7 3.0 1 2.9 2.7 MATTITLICK, NY 1 1952 WIND DESIGN SUB LICENSE# G74G 1-]11JECT TO DAMAGE FROM I LICENSE# 52G89-ME GROUND SEISMIC WINTER ICE BARRIER AIR MEAN SNOW DESIGN DESIGN UNDERLAYMENT FLOOD FREEZING ANNUAL LOAD' Speed" Topographic Special Windborne CATEGORY' Frost TEMP` REQUIRED" HAZARD59 INDEXi TEMP) (mph) effects, wind region debris zone"' Weathering' line Termite` depth' C�OF NEIV m 20 140 NO NO NO B SEVERE 3 FT MIIOD TO 15°F YES ZONE X FEMA 500 5 1°F In GjP 2�0 A A i MANUAL J DESIGN CRITERIA" W O ' Indoor m � Winter Summer design g p g heatmg temperature [ARRAYS#1, 3, G 7] [ARRAY#2] [ARRAYS#4 5] Elevation latitude heatm coolm Altitude correction factor Desi n temperature coolm 9 9 tempera difference �O V 103443 ture A �, - 108 FT 4 l°N 15°F 8G°F 1.00 70°F 75°F 55°F Ro�ss1oNv Wind Wind Coincident Winter PROJECT NAME Cooling temperature difference velocity velocity Daily range Summer humidity _ heating cooling Net bulb humidity ROOF FRAMING DETAIL 1 0 ]L[ 11j - U 15°F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% �32 GP @50%PH W z For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. LU Q N Q - a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth W strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as D_/ J z determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. MODULE MOUNTING CLAMP :1LLJ b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. 5CLAR MODULE � ,, C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. p J L Z O STAINLESS STEEL 3/8" d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined W BOLT AND NUT 0 LLJ O = on a site-specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also /^ L O see Figure R301.2(1).] NRIDGE ALUMINUM RAIL v J f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. ALUMINUM"L"BRACKET g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the ALUMINUM FLASHING Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: SHEET NAME i.The accompanying Flood Insurance Rate Map(FIRM), ii.Flood Boundary and Floodway Map(FBFM),and pp p/� iii.Related supporting data along with any revisions thereto. STRUCTURAL The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. ASPHALT SHINGLE ROOF h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.6.3.1,where there has been a history of local damage from the 5/1 G"x G"STAINLESS effects of ice damming,the jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall fill in this part of the table with"NO." STEEL LAG BOLT WITH 2 1/2"MIN THREAD i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) PENETRATION SEALED value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)" WITH GEOCEL 4500 j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method (EQUIVALENT OR BETTER) DRAWING SCALE (Base 32°F)." k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the AS NOTED jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. SHEET NUMBER n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or lb from ACCA Manual J or established criteria determined by the jurisdiction. ��/_/t o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at V `T elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. TAX MAP: 1 OOO-O5 5.00-OG.00-0 1 5.024 MOUNTING DETAIL (*I See Figure R301.2(4)B. Zoho Sign'Document ID:2A768FFA-M8Y_18WA7CQVR2DLKFCPS000AVNYMQ9WTXTZI4RCXWC DESIGN$DRAFTING BY: SOLAR ARRAY ON MAIN HOUSE 24.4 kW ELEMENT ENERGY LLC (G 1)CANADIAN SOLAR C5GR-400 400 WATT PV MODULES REVIEW BY J.M.NABCEP CERTIFIE (4)STRINGS Of(13)MICRO-INVERTERS(1)5TRING OF(9)MICRO-INVERTERS 051 1 1 2-1 23 -(5)STRINGS TOTAL OLAP MODULE TYPICAL TO UTILITY GRID REVISIONS STRINGS #1-4 DE5C1?PTI0N DATE REV R. ENPHASE 1 N ORIGINAL II-10-2023 r- ---------------- - BRANCH - - TERMINATOR 51-DIRECTIONAL - TYPICAL UTILITY METER *- ------------------- I-PHASE.240 V 1 -- I 1 N 1 MICRO-INVERTER POINT OF INTERCONNECTION ENPHA5E IQ8PLU5-72-2-US PER NEC 240.21(5)(1)6 G90.G4(A) 240 VAC, 1.21 A LENGTH OF TAP CONDUCTOR5 STRING #5 _ _ _ _ _ _ 97%CEC-WEIGHTED EFF. SHALL NOT EXCEED I OFT - - - - - - - NEMA G,UL LISTED - -- -- -- TYPICAL CONTRACTOR MAIN 5ERVICE D15CONNECT `----' --I--- `--- ---- `----- -----' ---- zaoV.2.0A ELEMENT ENERGY, LLC. 1 ENPHASE BRANCH 7470 SOUND AVE CIRCUIT CABLE TYPICAL MATTITUCK, NY 1 1952 1 1 LICENSE# G74G I-HI AC LOAD CENTER AC D15CONNECT LICENSE# 52G89-ME 240 VAC.100 A 1 NEMA 3P..UL U5TED 50 D D223NRB 1 (51 20 A DOUBLE FOIE BREA6EP.5 240 VAC. I DO A 1 (17 15 A DOU51E FO.E DREAKER NEMA 3R.UL L15TED FOR COMMUIIICATI(xl DEACE 1 N � �7 N � �J (z)too AFUSES !OF Nt;1,yy °A °A GATEWAY I OO A o AA�G+�G��;0 _ l 1 1 15A - MAIN SERVICE PANEL m it 2 N N } - - - - ---J I-PH.3-W 1 r- _- G ---- G --------------------------------------------------� 240 VAC zooA 443 N - -, AR��sstoNP� I 1 I I I EXISTING GROUNDING PROJECT NAME --------- ; ELECTRODE SYSTEM W LL1 I ; O U > lu z m L------------------------------------- ------------ ~ LLJ WIRE CONDUIT SCHEDULE >p C In n LLl � CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% I r J � z I.D.# ORIGIN DESTINATION 51ZE PER POLE QUANTITY DEBATE INSULATION 5IZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE DISTANCE g LW O Q 3)0.15(B)(3) 310.ISB)(2a)/(3c) O I INVERTERS COMBINER PANEL AWG#8 1 10 0.5 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I-114" 55QC 0.84 100 FT 1.5 1% N OR EMT C) W O 2 COMBINER PANEL AC DISCONNECT AWG#2 I 3 I THWN-2 AWG#8 I THWN-2 CU PVC 1-I/4" 459C 0.95 100 FT I.G9%Q O O 3 AC DISCONNECT I MAIN PANEL AWG#2 I 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I-I/4" 459C 0.95 10 FT 0.1 7% O ( O ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NP.TL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acit Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. (NEC G90.8(B)(1)]:(Isc)'(#ofstrin s)'(1.5G)= 1 9.GG A 3-LINE D IA. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 9 Modules per String 13 MAX. TO,AND LOCATED AS CL05E AS P05515LE TO THE NEAREST RIDGE, HIP,OR VALLEY. AWG#A,amp.GG A Temp oreDer A = e s I A 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 23.I A> 19.6G A,therefore AC wire size Is valid. Modules per Inverter I COMPLY WITH NEC 110.2G. #2 Inverter Output Wire Ampacity Calculation Number of Inverters GI 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output'(1.25)= 92.2G A Record low temp -109C FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACE550PIE5 TO FULFILL AWG#2,ampacity'(Temp Derate)'(Conduit Fill Derate)= 123.5 A Voc Temp Coefficient -0.24%/QC DRAWING SCALE APPLICABLE CODES AND STANDARDS. 123.5 A>92.2G A,therefore AC wire size 1s valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation THE CONTRACTOR SHALL 5IZE THEM ACCORDINGLY. Inverter Max Amperage output'(1.25)= 92.2G A Operatinq Current 13.0 A N .T.S. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#2,ampacity'(Temp Derate)'(Conduit Fill Derate)= 123.5 A Operatinq Voltacle 30.8 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 123.5 A>92.2G A,therefore AC wire size is valid. Max.System Volta6je 40.1 V SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 17.3 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR I1-500 G13L-4DBT LAY-IN LUG. AC SYSTEM SPECIFICATIONS SHEET NUMBER 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5itive/ne6jative) Max AC Output Current 92.2G A PV-5 OR O eratin AC Volta e 240 V 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000-055.00-OG.00-0 1 5.024 ,Zoho Sign'Document ID.2A768FFA-M8Y_18WA7CQVR2DLKFCPSQOUAVNYMQ9WTXTZI4RCXWC SERVICE METER OI O _ INSTALLATION NOTE DELEMENT ENERGY LLC ELEMENT ENERGY LLC ( 1 ) ALL LABEL SHALL BE INSTALLED IN REVIEW BY J.M.NAB 2-12PCERTIFIE ® � SOLAR PV SYSTEM PHOTOVOLTAIC 3 • • • 05 112_ 29 EQUIPPED WITH a SOLAR BREAKER >; • ACCORDANCE WITH THE 201 7 NEC RAPIDSHUT01( ® •• • • REQUIREMENTS. Revisionls OPERATING • •, DE5CRIPTION DATE REV (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL II-I0_2023 MAX SYSTEM VOLTAGE VDC SOLAR AC LOAD CENTER- OUTSIDE 4DO NOT RELOCATE THIS� REQUIRE FIELD VERIFICATION. :OVERCURRENTDEVICE (3) LABELS, WARNINGS) AND MARKING OTURN RAPID SHUTDOWN SWITCH TO O ® SHALL BE IN ACCORDANCE WITH NEC THE'OFF POSITION TO SHUTDOWN 1 10.21 (5). PVSYSTEMANDSHOCK HAZARD Lif THE ARRAY '! CAUTION -_ - - AC DISCONNECT I POWER TOTw5SERMEISA1S°SWRIED (4) THE MATERIAL USED FOR MARKING PRO. nM POLLowM,SOURCES W" —" i DMWH E=LO`TEDASS"°W" MUST BE WEATHER RESISTANT, I N 50LAK AC LOAD CENTER- INSIDE 2 A ® 'Ni EGMRaGE CONTRACTOR j � COMPLIANCE WITH NEC 110.2I (B)(3). ELEMENT ENERGY, LLC. �,� HR -1IL (5) THE PV SYSTEM CIRCUIT CONDUCTORS 7470 SOUND AVE THISEpU�dENi FED BYMULIIPLE �W DUAL POWER SUPPLY nP SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 105 SOURCES.TOTAL RAMNIS OFALL COMPLIANCE WITH NEC 690.3 I LICENSE# G74G 1-t11 OVERCURRENTDEVlCES EXCLUDING SOU DU LICENSE# 52G59-ME MA!NSUPPLYOVERCURRENT AND PV SOLAR DEVICE SHALLNOTEXCEm ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING affaCnYOFBURAR. OF NEW)- AS?` O Ezo A G O 3 r- ITT �t�ELECTRIC SHOCK HAZARD i PHOTOVOLTAIC SYSTEM c m I f COMBINERPANEL J y �� 2 TERIAINALSONTHEUNEAND DO NOTADD LOADS �O T03443 r IN THE OPEN POSTTIOIN ._ .I --- -- LOAD SIDES!.'IAY BE ENERGQED !I CONDUIT - OUTSIDE BUILDING � ARo�SsAoNP� ® ® - - -- -�----- --- ----. - - PROJECT NAME • • • LLB — DUAL POWER SU W Z 1JSVOURCES:UTILITYG7RJJDANDW Q SOLAR ELECTRIC • (J� MAIN SERVICE PANEL - OUTSIDE }- O A CAUTION SOLAR CIRCUIT j g W J z O O O _, CA AUTIMO,,// O SOLAR ELECTMCSYSTE)ACONNECiED J L.� © • • • 0 LLJ O 0 O MAIN SERVICE PANEL - INSIDE ,L '• — L ) (s) POWER SOURCE OUTPUT CONNECTION ® O ` DO NOT RELOCATE THIS SHEET NAME -OVERCURRENT DEVICE -- - -- LABELS AC DISCONNECT/BREAKER DRAWING SCALE 00 N .T.S. SHEET NUMBER PV-6 TAX MAP: 1000-055.00-OG.00-0 15.024 \�1 i Prellmma Technical r CanadianSo�ar . . - ry - r Information Sheet - ry_ ' � - HiKu6 (All-131ack) ALL BLACK MONO PERC 380 W - 405 W CS6R-380 1 385 1 390 1 395 1 400 1 405MS-HL MORE POWER 25 Industry Leading Product Warranty on Materials nears and Workmanship* Module power up to 405 W 405 W Module efficiency up to 20.7 96 25 Linear Power Performance Warranty* Years Lower LCOE&system cost 1A year 'power degradation no more than 2% Subsequent annual power degradation no more than 0.55% -Subject to the terms and conditions contained in the applicable Canadian Solar Limited Warranty Statement.Also this 25-year limited product warranty is available only for prod- Comprehensive LID/LeTID mitigation ucts installed and operating on residential rooftops in certain regions. technology,up to 50%lower degradation ............................................................................................................................... MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2015/Quality management system Better shading tolerance ISO 14001:2015/Standards for environmental management system ISO 450D1:2018/International standards for occupational health&safety PRODUCT CERTIFICATES* MORE RELIABLE IEC 61215/IEC 61730/CE/INMETRO UL 61730/IEC 61701/IEC 62716 Take-e-way ® Minimizes micro-crack impacts v � �== p pE � RusC E %50 *The specific certificates applicable to different module types and markets will vary, and therefore not all of the certifications listed herein will simultaneously apply to the Heavy snow load up to 7000 Pa, products you order or use.Please contact your local Canadian Solar sales representative ® wind load up to 5000 Pa* to confirm the specific certificates available for your Product and applicable in the regions in which the products will be used. ................................................................................................................................. CSI SOLAR(USA)CO.,LTD.Is committed to providing high quality solar photovoltaic modules,solar energy and battery storage solutions to customers.The company was recognized as the No.1 module supplier for quality and performance/price ratio In the IHS Module CustomerInsight •Pending testing confirmation.For detailed information, Survey.Over the past 20 years,it has successfully delivered over 67 GW please refer to the Installation Manual. of premium-quality solar modules across the world. .................................................................................................................................................................................................................................................................. CSI SOLAR(USA)CO.,LTD. 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94597, USA I www.csisolar.com/na I service.ca@csisolar.com ENGINEERING DRAWING(mm) CS6R-400MS/I-V CURVES A A Rear View Frame Cross Section A-A 14.1 14 - 13 -13 A-A 12 ---12 - 6-Q5 10 _ --10 - Grcundmg Hole I 35 -- -- i9. -________ _ 8.74x9 --- - Mounting Hole I 7 _` 7 _ M 6 6 . ._____.____.__ -__.-_-___ �_____-�__ 5 5 ._--___________ _____________-_-__ 4 4--__-_--______ .._--_-- e o0 3 3 2 -- 2 _- -_ Mounting Hole 0 o - , v v 1t 5 10 15 20 25 30 35 40 45 SO 55 60 5 10 15 20 25 30 35 40 45 50 55 60 ■ 100o W/m' S•c ■ ■ aoo W/n, 2s•c ■ ❑ t• ® 600 W/m,I 45•c ■ ■ 400 W/m' 65•c ■ ■ 200 w/m' ELECTRICAL DATA l STC* MECHANICAL DATA CS6R 38OMS 385MS 390MS 395MS 40OMS 405MS Specification Data Nominal Max,Power(Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp)30.0 V 30.2 V 30.4 V 30.6 V 30.8 V 31.0 V Cell Arrangement 108[2 X(9 X 6)] Opt.Operating Current(Imp)12.69 A 12.77 A 12.84 A 12.91 A 12.99 A 13.07 A 1722 x 1134 x 35 mm Open Circuit Voltage(Voc) 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V Dimensions (67.8 x 44.6 x 1.38in) Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 21.3 kg(47.0 Ibs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 mm tempered glass with anti- Operating Temperature -40°C-+85°C reflective coating Max.System Voltage 1500V(IEC/UQ or 1000V(IEC/UL) Frame Anodized aluminium alloy, J-Box IP68,3 bypass diodes Module Fire Performance TYPE 1 (UL 617301500V)or TYPE 2(UL 61730 Cable 4 mm2(IEC),12 AWG(UL) 1000V)or CLASS C(IEC 61730) Max.Series Fuse Rating 25 A Connector T6 or MC4 series Application Classification Class A Cable Length 1550 mm(61.0 in)(+)/ (Including Connector) 850 mm(33.5 in)()* Power Tolerance 0-+10 W *Under Standard Test Conditions(STC)of irradlance of 1000 W/ml,spectrum AM 1.5 and cell tempe- Per Pallet 30 pieces rature of 251C. Per Container(40'HQ) 780 pieces *For detailed information,please contact your local Canadian Solar sales and technical representatives. ELECTRICAL DATA I NMOT* CS611 380MS 385MS 390MS 395MS 40OMS 405MS TEMPERATURE CHARACTERISTICS Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Data Opt.Operating Voltage(Vmp)28.1 V 28.3 V 28.4 V 28.6 V 28.8 V 29.0 V Temperature Coefficient(Pmax) -0.34 IN/°C Opt.Operating Current(Imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A Temperature Coefficient(Voc) -0.26%/°C Open Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/°C Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A *Under Nominal Module Operating Temperature(NMOT),Irradiance of 800 W/chtspectrum AM 1.5, Nominal Module Operating Temperature 42 t 3°C ambient temperature20°C,wind speed i m/s. PARTNER SECTION ................................................................................................................... *The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going Innovation and product enhancement CSI Solar Co.,Ltd.reserves the right to make necessary adjustment to the Information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. ................................................................................................................... .................................................................................................................................................................................................................................................................... CSI SOLAR(USA)CO.,LTD. June 2022 1 All rights reserved I PV Module Product Datasheet v1.5C25 F23_J2_NA AAL IRONRIDGE Flush Mount System �f _ - - Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty ® Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. ' XR Rails(B XR10 Rail XR100 Rail XR1000 Rail Bonded Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. ^ G'opanninguopabi|ity ^ 8'oponningnapabi|ity ^ 12'aponningcopabi|ih/ ^ Self-drilling screws ^ Moderate load capability ^ Heavy load capability ^ Extreme load capability ^ Varying versions for rails ^ Clear and black finish ^ Clear and black finish ^ Clear anodized finish ^ Forms secure bonding ---- Clamps & Grounding 8 UFOs Stopper Sleeves Grounding Lugs 88icm»imnmrtmrKitm - . . . � . . Universal Fastening Objects Snap onto the UFO boturn Connect arrays to Mount N1|aovPOotoXR bond modules torails. into a bonded end clamp. equipment ground. Roils. ^ Fully assembled &|ubed ^ Bonds modules torails ` Low profile ^ Bonds devices torails ^ Single, universal size ^ Sized to match modules ` Single tool installation ^ Kit comes assembled '-- ^ Clear and black finish ` Clear and black finish ^ Mounts in any direction ^ Listed toUL2703 ---- Attachments 8 FUmmhFmut2 Conduit Mount S{ottmdL-Fewt Bonding Hardware ni \ | �^ Flash and mount XRRails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XRRails with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. ^ Twist-on Cap eases install ^ Twist-on Cap eases install ^ Secure rail connections ` T&Square Bolt options ^ Wind-driven rain tested ^ Wind-driven rain tested ^ Slot for vertical adjusting Nut uses 7/1G"socket ' ^ Mill and black finish ^ Secures 3/4"or1^conduit ` Clear and black finish ^ Assembled and lubricated- Resources ENPHASE. Tr, f pin ENPHASE HA106 IQ8 and IQ8+ Microinverters Easy to install Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with- defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter . r Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the Power between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability !— - Produce power even when the Enphasegrid is down* More than one million cumulative - �{ hours of testing Class II double-insulated Part of the Enphase Energy System,I08 Series IQ8 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative test high- la the Optimized for Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- powered PV the la and analysis software. leading limited warranty of up to 25 years. p S Microgrid-forming • Complies with the latest advanced grid support** CERTIFIED SAFETY Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily to IQ8 Series IQ8 Series Microinverters are UL Listed as Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other •Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. ••I08 and IQ8PIus supports split phase,240V IQ8SP-DS-0002-01-EN-US-2022-03-17 installations only. 108 and IQ8+ Microinverters INPUT 1ATA(OCI 108-60-2-US1:• I Commonly used module pairings' w 235-350 235-440 i 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 Module compatibility 60-cell/120 half-cell half-cell MPPT voltage range V 27-37 29-45 - I Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 _ I Max input DC voltage V 50 60 Max DC currentz[module Isc] A 15 Overvoltage class DC port i II I DC port backfeed current mA 0 PV array configuration i 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT 1• 1: .1 A: Peak output power VA 245 1 300 - - I Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V i 240/211-264 Max continuous output current A 1 1.0 1.21 i Nominal frequency Hz 60 _ Extended frequency range Hz 1 50-68 AC short circuit fault current over 3 cycles Arms' 2 Max units per 20 A(L-L)branch circuit' i 16 13 Total harmonic distortion <5% I I Overvoltage class AC port III � - I AC port backfeed current mA I 30 Power factor setting 1.0 i Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging i . I Peak efficiency % i 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw I 60 MECHANICAL DATA Ambient temperature range -400C to+600C(-40°F to+1400F) Relative humidity range 4%to 100%(condensing) ' - I DC Connector type" MC4 Dimensions(HxWxD) I 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") � Weight 1.08 kg(2.38 Ibs) I Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class Ildouble-insulated,corrosion resistant polymeric enclosure i Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 I I Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2026 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to i manufacturer's instructions. _ _ I (1)No enforced DC/AC ratio.Seethe compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2022-03-17