Loading...
HomeMy WebLinkAbout48344-Z TOWN OF SOUTHOLD °�Og�ff01 C BUILDING DEPARTMENT y a ' TOWN CLERK'S OFFICE Wog SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48344 Date: 9/28/2022 Permission is hereby granted to: Wilson, Thomas 1785 Breakwater Rd Mattituck, NY 11952 To: Install roof mounted solar panels to an existing accessory building applied for. At premises located at: 1785 Breakwater Rd., Mattituck �� SCTM # 473889 7' Sec/Block/Lot# 106.-8-20.5 Pursuant to application dated 8/16/2022 and approved by the Building Inspector. i To expire on 3/29/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $200.00 Building Inspector a SOUI,yo� k3 f TOWN OF SOUTHOLD BUILDING DEPT. �,f °ycourm�� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: VoiA OLZP/tf DATE �'aa�� INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS --C►o FOUNDATION (1ST) rG Z� ------------------------------------- FOUNDATION (2ND) z cn H ROUGH FRAMING& UZIa PLUMBING t� INSULATION PER N.Y. STATE ENERGY CODE 3daa o aP- /70 ins a. a� voi . FINAL ADDITIONAL COMMENTS —_ 3 ` c o z Ln W � ►o H O z � x H x d H f ��SUFFO(t�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone 631 765-1802 Fax 631 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT IF 5Z For Office Use Only 3 M AUr 1 h gn99 r PERMIT NO. Building Inspector: C31�1?v1111CU D Pis 1:LI/ a 10 lwi Applications and forms must be filled out in_tlteir entirety:lgcpmplete;''J.: S_l.lTFi!' .applications.will•norba accepted. Where the Applicarit.is notahe owner;an.,;; Owner's Authorization:form"(Page 2),s'61l.be completed:- Date: OWNERS)'OF PROPERTY: Name:Mary Lou Wilson SCTM#1000-106-8-20.5 Project Address:1785 Breakwater Road, Mattituck, NY 11952 Phone#:516-606-9663 Email:luvmyjets@gmail:com Mailing Address: 1785 Breakwater Road, Mattituck, NY 11952 NTACT PERSO N: CO , Name: Tammy Lea/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:permitting@sunation.com PROFESSIODESIGN NALi NFORMATION: Name: William Fisher Mailing Address:509 Sayville Blvd, Sayville, NY 11782 ,Phone#:631-786-4419 Email:bill@fisher-ny.com CONTRACTOR INFORMATION • = ' Name:Scott Maskin/Sunation Solar Systems Mailing Address:171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:permitting@sunation.com 'DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: [--]Other Solar panelsJO on roof CLC builr1incl $ 71.,D3S•1)-D Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes BNo 1 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of ert ro p p Y Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? OYes @No IF YES, PROVIDE A COPY. ❑ Check Box After Reading; The owner/contractor/design professional Is responsible for all drainage and storm water Issues as provided b Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Pertnit pursuant to the Buid b Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,far the construction of buildings, id ng y additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building codeZone housing code and regulations and to admit authorized Inspectors on premises and In building(s)for necessary Inspections.False statements made herein are Punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print nam_ e):___S-cOtt Maskin Signature of Applicant: ,. @Authorized Agent ❑Owner Date: 1.. a a 1 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin (Name of individual signing contract)above named, being duly sworn,deposes and says that(s)he is the applicant (S)he is the Contractor (contracto of said owner or owners, and is duly authorized tor Corporate perform or have performed the said rk and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this O� day of De co-k')o 20 d, ary Public TAMMY LEA Notary Public,State of New Yo►k PR®PERTY®WNER AUTFI®R1�r4T1®� P gistrationNo.OI E64108 2 Oualiffed in Suffolk County (Where the applicant is not the owner) Commission Expires November 2,20J Mary Lou Wilson 1785 Breakwater Road residing at d Mattituck Scott Maskin do hereby authorize to apply on m�Son the Town of Southold Building Department for approval as described herein. Mary Lo0,202110:16 EST) Dec 20,2021 Owner's Signature Mary Lou Wilson Date Print Owner's Name 2 N Y�S I F PO Box 66699,Albany,NY 12206 New York State Insurance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 753118816 �' � GCG RISK MANAGEMENT INC , 100 CHURCH STREET-SUITE 810 , NEW YORK NY 10007 5 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 670-2 243630 01/01/2022 TO 01/01/2023 12/14/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS' COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,I(SUiRICE FUND UNDERWRITING VALIDATION NUMBER: 103973329 111111111I10 0 0 0 0 0 0110�00�00994033041Io illul Form WC-CERT-NOPRINT Version 3(0 8/292 0 1 9)[WC Policy-21606702] U-26.3 64 [00000000000099403304][0001-000021606702][#CZ][15782-06][Cert_NoP{ERT 1][01-00001] <NTE RK WorkersCERTIFICATE OF INSURANCE COVERAGE arE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a. Legal Name&Address of Insured(use street address only) 1b. Business Telephone Number of Insured SUNATION SOLAR SYSTEMS INC 631-737-9404 171 REMINGTON BOULEVARD RONKONKOMA,NY 11779 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 753118816 2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Town of Southold ShelterPoint Life Insurance Company 54375 Route 25 3b. Policy Number of Entity Listed in Box"1 a" PO Box 1179 DBL631187 Southold, NY 11971 3c.Policy effective period 10/01/2021 to 09/30/2022 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. Fj C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. I Date Signed 12/1/2021 B Y (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier, this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this fonn. DB-120.1 (10-17) �I�IIII IIIIIIIIDB_120.1 (10_17) 1111111 0 DATE(MMIDDIYYYY) A� F2/11/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: The Horton Group PHONE 10320 Orland Parkway 1AICE-Mayo Et I:708-845-3000 Arc No Orland Park IL 60467 ADDRESS: r-ertificates@thehortongroup.com INSURERS AFFORDING COVERAGE NAIC q INSURER A:Evanston Insurance Company 35378 INSURED SUNASOL-01 INSURER B:The Continental Insurance Company 35289 SUNation Solar Systems, Inc. 171 Remington Blvd INSURERC:AXIS Surplus Insurance Co. 26620 Ronkonkoma NY 11779 INSURER D:Travelers Property&Casualty Company of America 25674 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:1814587611 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. YFXP INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF MM/DDIYYYY LIMITS LTRWVD A GENERAL LIABILITY Y Y MKLVIENV103336 2/11/2022 2/11/2023 EACH OCCURRENCE $1,000,000 DAMAGE RENTED X COMMERCIAL GENERAL LIABILITY PREMISES Ea occurrence $300,000 CLAIMS-MADE F—IOCCUR MED EXP(Any one person) $10.000 PERSONAL&ADV INJURY $1.000,000 GENERAL AGGREGATE $2,000.000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $2,000.000 POLICY X PRO- LOC $ B AUTOMOBILE LIABILITY Y Y 7018308202 2/112022 2/11/2023 COMBINED SINGLE LIMIT Ea accident 1 000 000 I ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE $ HIREDAUTOS AUTOS paraccidentt $ C UMBRELLA LIAR X OCCUR Y Y P-001-000795195-01 2/112022 2/11/2023 EACH OCCURRENCE $3.000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $3.000,000 DED RETENTION$ $ WORKERS COMPENSATION WC STATUS OTH- AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE❑ N/A E.L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ D Builders Risk Y QT-630-2T010874-TIL-22 2/112022 2/112023 500,000 Y DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) Additional Named Insureds:SUNation Service Inc;SUNation Electric Inc;SUNation Commercial Inc;SUNation Cares Inc Additional Insured on a primary and non-contributory basis with respect to general liability and auto liability coverage when required by written contract.Waiver of subrogation applies to general liability and alltD liability in favor of the stated additional insureds when required by written contract.Excess follows farm. Town of Southold is included as an additional insured as required by written contract and the CG 2012(State,Governmental agency,or Political subdivision permits or authorization)is included on the policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 26(2010/05) The ACORD name and logo are registered marks of ACORD e. Suffolk County Dept.of Labor,Licensing&Consumer Affairs r MASTER ELECTRICAL LICENSE Ck Name SCOTT A MASKIN This certifies that the Business Name bearer is duly licensed SUNATION SOLAR SYSTEMS INC by the County of suffolk License Number:ME-33412 Rosalie Drago Issued: 06/24/2003 Commissioner Expires: 06/01/2023 f r ' I i 4 �I { ;1 ,1 RECEIPT SUFFOLK COUNTY GOVERNMENT DEPARTMENT OF LABOR, LICENSING,AND CONSUMER AFFAIRS ACTING COMMISSIONER ROSALIE DRAGO P.O. BOX 6100, HAUPPAUGE, NY 11788 (631) 853 4600 Today Date: 02/25/2020 Application: H-44104 Application Type: Home Improvement License Receipt No. 402742 Payment Method Ref. Number Amount Paid Payment Date Cashier ID Comments Check 31300 $400.00 02/25/2020 GAB Renewal Contact Info: SUNATION SOLAR SYSTEMS INC SCOTT A MASKIN 171�REMINGTON BLVD. , RONKONKOMA, NY 11779 Work Description: Suffolk county Dept.of Labor,Licensing&consumer Affairs HOME IMPROVEMENT LICENSE Name SCOTT A MASKIN Business Name This certifies that the suNATION SOLAR SYSTEMS INC bearer is duly licensed by the county of suffolk License Number: H144104 Rosalie Drago issued: 03/06/2008 Acting Commissioner Expires: 03/01/2022 h� 4OG Ire'. BUILDING DEPARTMENT Electrical Ins p egt9r TOWN OF SOUTHOLD fw Town Hall Annex- 54375 Main Road - PO Box 1179-/ Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 tog errg South oldtown n y.gov - seandCa).southoldtownny. qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin EE License No.: 33412-ME email: perrnittin i(a-)su nation.com Address: 171 Remington Blvd. Ronkonkoma, NY 11779 L Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Mary Lou Wilson Address: 1785 Breakwater Road, Mattituck, NY 11952 Cross Street: Phone No.: 516-606-9663 Bldg.Permit#: Z email: luvmyjets T @gmail.com Tax Map District: 1000 L- Section: 106 Block: 8 Lot: 20.5 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of s roof Circle All That Apply: Is job ready for inspection?- YES / NO Rough In Final Do you need a Temp.Certificate?: YES / NO Issued On Temp information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters d :ete 0 M Old Meter# I New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals Reconnected Service? Y 1 2 H Frame Pole Work done Additional Information: -1--- ne on Service? Y ]N PAYMENT DUE WITH APPLICATION Request for inspection Form.xis • 1 APPROVED AS NOTED DATE'S aB.P. # sue! COMPLY WITH ALL CODES OF a FEE�aQD-ILBY NEW `CORK STATE & TOWN CODES NOTIFY BUILDING DEPARTMENT AT AS REQUIRED AND CONDITIONS OF 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS SOUTHOLD TOWN ZBA ` 1. FOUNDATION -TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING,PLUMBING, S0UTH0LD TOWN PLANNING ROAR0 STRAPPING, ELECTRICAL&CAULKING 3. INSULATION S0UTH0LD TOWN TRUSTEES 4. FINAL-CONSTRUCTION &ELECTRICAL MUST BE COMPLETE FOR C.O. N,Y.S, DEC ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ELECTRICAL INSPECT80N REQUIRED Ji5conne4 o II ,,,, --, UTILITY 9 PROPOSED RES I D E NT..I A L PLAN KEY ' Q_"-SERVICE DISCONNECT OISCONNECT PV1-0 COVER SHEET IZI PLY SIDE CONNECTION PARTIAL ROOFPLAN . - PHOTOVOLTAIC SY'STEI% Al 1 A -0-2 ATTACHMENT SPACING PLAN �-GAS METER �1 4 ROOF ACCESS PLAN Q' MAIN SERVICE PANEL EROA S1-1 STRUCTURE ©-SUB PANEL 171 RE IN SOLAR SYSTEMS INSTALLER 4355 I7•-WIRELESS ROUTER � 171 REMINGTON BOULEVARD � INSTALLER E1-1 ONE-LINE DIAGRAM �-INVERTER RONKONKOMA,NEW YORK 11779 NUMBER E2 1 PV LABELS I Q-ENPHASE IO COMBINER :;' ;'r, G1-1 PV PHOTOS -PANELPHOTOVOLTAIC U .� .�vo�E, Wilson Residence Q-ELECTRIC VEHICLE CHARGER ` 1785 Breakwater Road, Mattituck, NY 11952 *-ENPHASEENVOY VV -3 VVV < Cr.•-SENSE CONSUMPTION MONITOR Drawn By:T. MacCallum -08/09/2022 [J^'j. -AC DISCONNECT • .^ -TESLA GATEWAY ' ` -TESLA POWERWALL �I{I �C OF ENPHASE 10 LOAD CONTROLLER v f� I � Q' Om G•�i �-ENPHASE IOIOBATTERI' _ FISHER ENGINEERING SERVICES, P.C. 509 Sayville Boulevard g-ENPHASE 10 3 BATTERY > Sayville, New York, 11782 Q-GENERATION PANEL " r •,n CC ©-BACKED UP LOADS CENTER /T j Licensee No. 074659 O-VENT PIPE -- $ . a�n ;;,,�;�, a, (631)-786-4419 �` Bill@Fisher-NY.com •••-EXTERIOR LOCATION -IST FLOOR LOCATION ' -BASEMENT LOCATION i Building Review Note -GARAGE LOCATION Town building examiner has received the enclosed document for minimum acceptable �— plan submittal requirements of the town as specified in the building and/or Residential PROPOSED PV SYSTEM j Code of the State of New York. This review does not guarantee compliance with that code. that responsibility is guaranteed under the seal and signature of the New York State licensed design professional of record. That seal and signature has been Module Type/Qty:I(86) LG375Q1 C-V5' interpreted as an attestation that,to the best of the licensee's belief and information the work in this document is: Module Dimension: 66.9"x 44"x 1.57" Accurate • Conforms with governing codes applicable at the time of submission Module Weight/PSF: 38.58 Ibs/2.1 PSF i0 Conforms with reasonable standards of practice and with view to the Micro Inverter: (86)Enphase IQ8PLUS-72-2-US safeguaee.rding of life,health,property and public welfare is the responsibility of the i System DC Rating: 32.25 kW Estimated AC Production: 39,415 kWh/yr e ( w i Structural Statement �j The existing structure is adequate to support the new loads imposed by the Production Source: Aurora u photovoltaic module system including uplift and shear. The existing rafter sizes and dimensions conform to IRC-2018 table R802.4.1(2)-Rafter Spans. PV Notes 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be provided where necessary. An in depth description of each applicable code reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more N than 6-inches above the surface of the roof. 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and inspection. FULL HOUSE ROOF PLAN SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PVImO COVER PAGE JOB# 20279 REVISION # N/ASUNa 10 F= 3 REVISED BY N/A . Solar as it should e 01 NFL (t F CIRCUIT 6 RIDGE FISHER ENGINEERING RIDGE CAPPING 48W 2-6* SERVICES,P.C. (TYP.) —————— 509 Sayville Boulevard -- --————————— ENT PIPE- Sayville,New York,11782 ,, TO PVC Licensee No.074659 ROOF ROOF 3 n (631)-786-4419 Bill@Fisher-NY.com 61 o A14 "AA Solar as it should be SuNatio Aj PHOTOVOLTAIC MODULE SuNation Solar Systems (TYP.) \,IF 171 Remington Blvd. Ronkonkoma,New York 11779 A T/ V !7/ L CIRCUIT 4 (631)-750-9454 ok -4 INW STALDLERa: 0 1 NUMBER 4355 UJ VENT PIPE ROOF AREA 3-0 PVC JOB NUMBER D L L L CIRCUIT 5 CIRCUIT 7 GUTTER CIRCUIT 8 20279 RIDGE ROOF 2 VENT VENT PIPE VENT RIDGE WX 14" YO PV 14"X 14' B, \-Z. CQ ROOF 1 C\j C\I Z Z RIDGE CD 3y2-- CIRCUIT 3 0 C) 0 — C: 16 01 Co L 0 co U. C.) C: 0 CZ CZ TZ CZ 473 (S r, -,1 0 C C- 4; V, 41 0 0 Co LO 00 0 L CIRCUIT 1 L CIRCUIT 2 GUTTER Attachment Spacing: Portrait Attachment Spacing: Landscape Roof# Roof Description jModules Azimuth Tilt Pitch Interior Edge I Corner Interior Edge Corner Southeast Roof 26 1540 260 6.9/12 64" 32" 11 16" 64" j 4811 4811 1/8"= 1'-011 64 11 i 64 3211 I 2 BOH Southwest Roof 18 2440 220 5.9/12 1611 11 48" 4811 3 South Roof j 42 170- 26- 6.9/12 64" 32" 16" 64" 4811 4811 A1 = 1 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS of N (NY) R324.6 Roof access and pathways. Roof access, pathways and setback requirements shall be provided in accordance with Sections -- s 324.61 through R324.6.2.1. Access and minimum spacing shall be ,quired to provide emergency access to the roof,to provide pathways io specific areas of the roof, provide for smoke ventilation opportunity ,a areas and to provide emergency egress from the roof. ?; _ ;c Exceptions: DE,,DNEC POpL Np,JSE _ FISHER ENGINEERING 1. Detached, nonhabitable structures, including but not limited to SERVICES,P.C. detached garages, parking shade structures, carports, solar 509 Sayville Boulevard trellises and similar structures, shall not be required to provide Sayville,New York,11782 roof access. Licensee No.074659 419 2. Roof access, pathways and setbacks need to be provided l@Fisher- Y.c IT VEVTI_4TpN Bil I @Fisher-NY.com where the building official has determined that rooftop operations will not be employed. 1J2�PRO�OSeD PV MOp'JLEi 3. These requirements shall not apply to roofs with slopes of two _ S��� ➢ �s units vertical in 12 units horizontal (1 7-percentslope)or lesson `a1ar as it should'be NY R324.6.1 Pathways. Not fewer than two pathways, on separate i 3 su71 Re solar systems [ ] Y P Y P o 171 Remington Blvd. roof planes from lowest roof edge to ridge and not less than 36 inches Ronkonkoma,New York 11779 (914 mm)wide, shall be provided on all buildings. Not fewer than one EMI (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. y For each roof plane with a photovoltaic array, a pathway not less than NYSERDA 4355 36 inches (914 mm) wide shall be provided from the lowest roof edge ` IN to the ridge on thee same roof plane as the photovoltaic array, on an NUMBER 0 adjacent roof plane, or straddling the same and adjacent roof planes. Pathways shall be over areas capable of supporting fire fighters o JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal ( F obstructions such as vent pipes, conduit, or mechanical equipment. 20279 Pathways on opposing roof slopes shall not be located along the same T'T' `9 plane as the truss, rafter, or other such framing system that supports ""illi TpSo� pathway. Q I� j Exception: P� I> - N 1. Access pathways shall not be required on roof slopes containing photovoltaic modules, panels, or an array where the opposing o or adjacent roof slope is an access roof. } N Z Z _O 119,PROPOSED PV MODULES O L) Q7 Access Roof-A roof surface that: I— m Y o rMLRWAV a) m E 1. Can be accessed from the ground by the fire service. 2 2. Is capable of providing fire service access to the ridge or peak O ¢ Ca c° U of an opposing or adjacent roof surface that contains Z o m photovoltaic modules,panels,or an array. W 3. Is relative) free of vents,skylights,conduits,mechanical F- ~ Y equipment and other such obstructions. m 4. Does not contain photovoltaic modules, panels or an array, or is m a single ridge roof where the maximum edge to edge width of Ca L„ 0 the photovoltaic panel system does not exceed 33 percent of A� m the ridge length. I T i I [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be -la•-VENLTpN located less than 18 inches(457 mm)from a horizontal ridge. "' 'A " „ VENTILA➢DN [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels a ' k t' = 16--VENII '. and modules installed on dwellings shall not be placed on the portion 1> of the roof that is below and emergency escape and rescue opening. V A pathway not less than 36 inches (914 mm)wide shall be provided to I the emergency escape and rescue opening. LIi6•PROPOSED PV WOM'LES - N A1 =4 ' ROOF ACCESS PLAN i OF, /V Typical Attachment Method C-1)Q SNAP'N'RACK ULTRA RAIL RIDGE RIDGE �L-FOOT AND RAIL ASSEMBLY FISHER ENGINEERING SERVICES,P.C. Sayville509 PHOTOVOLTAIC 19'-11" PHOTOVOLTAIC 20'-1" I Sayville,New York,11782 Licensee No.074659 MODULE MODULE (631)-786-4419 Bill @ Fish er-NY.com 7 3/4"MODULE SPACING 3/4"MODULE SPACING (2)S.S.304 5.OMM X 60MM BETWEEN ROWS AND BETWEEN ROWS AND WOOD SCREW FASTENER �® COLUMNS(TYP.) COLUMNS(TYP.) i SUNatio Solar as it should be RT-MINI ROOF ATTACHMENT SUNation Solar Systems RAIL RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 RAFTER RAFTER (1)LAYER (631)-750-9454 2"X 10"/16"O.C. 2"X 10"/16"O.C. SHINGLE E(TYP) IN SALLE NUMBER R 4355 JOB NUMBER SOFFIT SOFFIT 20279 PLYWOOD DECKING EXTERIOR EXTERIOR (TYP.) WALL WALL A WOOD FRAMING 16'-5.25" —I 16'-7.5" —I (TYP.) ATTACHMENT TYPE APPLIED TO-ROOF"1,2,3" ROOF SECTION (TYP.) - ROOF "1&2" ROOF SECTION (TYP.) - ROOF "3" SCALE: N.T.S. SCALE: N.T.S. N to M N ,— N T 0 � N Z a� 0 z a) Co U 0 SOLAR MODULE FRAME 0 U NOTE:3/4"SPACING H ate-'' BETWEEN MODULE ROWS Q 0 c, a tV s '„-, Roof# Rafter Size/Spacing Max Span Material Layers Sheathing � ° As ;eeeee� T AND COLUMNS. oo oo oo oo ¢ CZ oo°coo° aD r 1 Composite Shingles Plywood o°c°af°o°°o, 55 HEIGHT ADJUSTABLE O co 1 2" x 10"/16" O.C. 16'-5.75" p 9 1 Y to°co�000°d,o�oo�°oo .. L-FOOT(TYP.) z o 0 0 oc oocood- _ CZ 2 2"x 10"/16" O.C. 10'-7.5" Composite Shingles 1 Plywood END CLAMP LU 0 3 2" x 10"/16" O.C. 16'-7.5" P 9 1PlywoodT (TYP.) — a� Composite Shingles al ,� ° Ii. °°'Q �— SNAP'WRACK 00 �y00'I CC° CO�P ULTRA RAIL °OQJF�UO°O IOCOOaOO < 6.0" (TYP.) m i000(oTl00000ao�, �lco HEIGHT OFF OF i ROOF SURFACE m CZ j I FIT MINI (TYP.) ! I j Typical Module ` PEST WRAP CUT - r AWAY FOR Side Profile CLARITY I CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL I UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX GROUND SNOW SPEED(MPH.) TOPOGRAPHIC SPECIAL WIND ZONE WIND BORNE DEBRIS CATEGORY WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE REQUIRED TEMPERATURE LOAD EFFECTS ZONE S 1 - 20 PSF 140 B YES 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 LHEAVY EXAMINER STRUCTURE OF Utit20124ov lity Service Cl) Enphase A/C Branch Circuit(typ.) EXISTING c? GENERATOR n Enphase Microinverter(typ.) SUPPLY-SIDE • 4 e.074r9y CONNECTION COMBINER Module J-Box(typ.) I ' / t�f �- PANEL ENPHASE GATEWAY . . . . (Naloads.moniI.nngoMyl 150A 150A 1 400A l 200A 1 I 200A FISHER ENGINEERING �_ MAIN MAIN l MAIN J MAIN / MAIN I SERVICES,P.C. PV Module(typ.) 2P20A 2P15A 509 Sayville Boulevard Circuit#8 Gateway ENPHASE ENVOY S� _ 6 Sayville,New York,11782 �12P261A PzoA (No loads.mwrt...g onlyi zPzoA Licensee No.074659 EGC Attached To Rail(typ.) Envoy Automatic cuit#7 f� — Relay s _ s _ (631)-786-4419 6ARAGE PV • Bill@Fisher-NY.com ENPHASE BRANCH CIRCUIT#8cuit#6 _ / _ Pass-Thug I ENPHASE BRANCH CIRCUIT#7 2P20A Lug T - 2P20A Circuit#4 i • �\ �, S ■Na i_` � Circuit#5 ARx�.f®TI/1 CS's®�f' w n ENPHASE BRANCH CIRCUIT#6 2P20A 2P20� r G 4 circus#3 Circuit#t dolor as it should be ENPHASE BRANCH CIRCUIT#5 �,— o TRENCH I SUNation Solar Systems 2P20A ENPHASE Circuit#2 a EGC I IQ COMBINER3C 'I G ENSE MONITOR Cj I IG I G Ronkonkom171 ea,lngton NewYorkd11779 ENPHASE BRANCH CIRCUIT#4 l �jll I IN,io—,mamio.mgonly) AC DISCONNECT AUTOMATIC MAIN MAIN (631)-750-9454 PANEL r) TRANSFER SERVICE SERVICE ENPHASE BRANCH CIRCUIT#3 I �i PHOTOVOLTAIC ) LI SWITCH PANEL I PANEL NYSERDA ENPHASE BRANCH CIRCUIT#2 t 2 3 Nate:Leave a blank space TRENCH INSTALLER 4355� J / ENPHASE BRANCH CIRCUIT#1 above each Enphase ROOF ATTIC EXTERIOR branmm¢u"breaxerper NUMBER manvracmrer. EGC 6 JOB NUMBER BUILDING 2 0 2 79 GROUNDING ELECTRODE CONDUIT AND CONDUCTOR SCHEDULE TAG CONDUCTOR CONDUIT RUN TYPE GAUGE QUANTITY TYPE SIZE LENGTH 1 Enphase Q-Cable 12 16 N/A N/A 15' 2 Type NM 10 16 N/A N/A 30' 3 HWN-2 10 16 PVC SCH.80 1 1.25" 15 N GC 4 j 1 PVC SCH.80 1.25" 15' to W 4 HWN-2 4 j 3 PVC SCH.80 1.25" 135, T N GC 8 1 PVC SCH.80 1.25" 135' } N 5 HWN-2 1/0 3 PVC SCH.80 1.5" 130. z O GC 6 1 PVC SCH.80 1.5" 130' Y 00 6 HWN-2 1/0 3 PVC SCH.80 1.5" 10. Z U O GC 6 1 PVC SCH.80 1.5" 10 � a E rn a) O U � `a � I z c O I>3 Ot Ot Maximum AC Operating Current w U) OC Circuit# PV Module Y• Micro-Inverter Y• P 9 Ir-W _� 1 LG37501 C-V5 13 Enphase IQ8PLUS-72-2-US 13 15.73 A ~ a 2 LG37501 C-V5 13 Enphase I108PLUS-72-2-US 13 15.73 A 3 LG37501 C-V5 10 Enphase I108PLUS-72-2-US 10 12.1 A m !n p 00 4 LG375Q1 C-V5 8 Enphase IQ8PLUS-72-2-US 1 8 g.68 A 5 LG375101 C45 3 ; Enphase I108PLUS-72-2-US 3 ! 3.63 A r 6 LG375Q1 C-V5 13 Enphase IQ8PLUS-72-2-US 13 15.73 A 7 LG37501 C-V5 j 13 I Enphase IQ8PLUS-72-2-US i3 ! 15.73 A 8 i LG375Q1 C45 13 Enphase IQ8PLUS-72-2-US 13 15.73 A Maximum AC Operating Current(Total) 104.06AE1 = 1 ONE-LINE DIAGRAM LABEL LOCATION: LABEL LOCATION: �P`C` OF URCE ® ® ® c CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ ® — — ® — MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE s' • CEILINGS/FLOORS OR MORE THAN 10'. DISCONNECT IF APPLICABLE. NEC 2017 690.31(G)(3) • NEC 2017 705.10 ��a i� J � ��; 7: .0 • e o ® e e LABEL LOCATION: Second •• SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND tLQcated -xt to - -r Pan FISHER ENGINEERING e •. CURRENT VALUES ON DISCONNECT LABELQQRRGNT: . 509 SayvlilCle ES Boulevard Sayville,New York,11782 NEC 2017 690.54/NEC 2017 690.13(B) NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO Licensee No.074659 THE BUILDING MAIN SERVICE DISCONNECT. (631)-786-4419 Bill@Fisher-NY.com This building is equipped with an Service Interconnected Electric Power ��� �8 Production Source solar as it should be ELECTRIC SHOCK HAZARD ®_ HISTAG SUN1 t S Remington Blvd. DO NOT TOUCH TERMINALS Source Type: Ronkonkoma,New York 11779 Solar Photovoltaic (631)-750-9454 TERMINALS ON BOTH THE LINE AND Primary Service Disconnect Disconnect is Located: Interior. LOAD SIDES MAY BE ENERGIZED Service s Basement:_ Garage:_ Exterior. NY;TAL IN THE OPEN POSITION e -° in:Main Front:_ Rear._ LH Side: ® ® NUMBER R 4355 PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE RH Side: Other Location: _ WHENEVER THEY ARE EXPOED TO SUNLIGHT J y U. ® RAPID JOB NUMBER SUNation Solar S stems 631-750-9454 www.sunation.com ®• 20279 LID M N T N r o >- CC\1 z rn 0 00 z m o O -0 cc N (t3 O LL C U w a cal Cz a Y m Cd m m Cal 00 of i E2= 1 PV LABELS �� OF /y -7- . t•t �.. _ FISHER ENGINEERING SERVICES,P.C. 509 Sayville Boulevard y ti, �,.- .' 1` r•— ' 4 Sayville,New York,11782 Licensee No.074659 1 _ (631)-786-4419 Bill@Fisher-NY.com �.- �,�, i n N Satuobe j q1! - Y � Solar a '�+�•�,• ,�. �, m•, � UNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 s (631)-750-9454 _ NYSERDA ' ` INSTALLER . .� �O NUMBER 4355 flo- _ JOB NUMBER 20279 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF N LO I }• N -- Z rn O e -- Z (D O O v _ _ Q E Cz Cl Cz co Cz 00 ' r i. SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP Gi = 1 PV PHOTOS 17. 17 i,1�: i, LG375Q1 C-V5 375W LG NeONO R is powerful solar module that provides world-class performance.A new cell structure that eliminates electrodes on thefront maximizes the utilization of tight and enhances reliability g LG NeONO R is a result of LG's efforts to increase customer's - --•� values beyond efficiency.LG NeON°R features enhanced durability, ♦ •��� performance under real-world conditions,an enhanced warranty ♦ ♦••� " and aesthetic design suitable for roofs. • MPPOVm PPODUCT DVE C �L US C E a.s.r.e.e e.. .2 51' r YEAR •rr r• :r• WARRANTY Features Aesthetic Roof Extended Product Warranty dllip\ iS•, u,j LG NeONO R has been designed with LG has extended the product warranty M aesthetics in mind:the lack of any of the NeONe,R to 25 years,which is electrodes on the front creates an top level in the industry. improved,modern aesthetic. Enhanced Performance Warranty More generation per square meter The LG NeONO' R has an enhanced The LG NeONO R has been designed to performance warranty.After 25 years, significantly enhance its output,making LG NeONO R is guaranteed at least it efficient even in limited space. 90.8%of initial performance. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics LG Electronics is a global leader in e:ectrnnic products:n the clean energy markets by offering solar PV panes and energy storage systems.The company first embarked or.a solar energy source research prog-arn in.1985.s:.pported by LC Gro::,,vast experience iP the Semi-condutror,l.[J,chemistry and materials ndustnes In 2010,LG Solar successfui., LU e released its firs:hloncX'"se�les is the market,:vl"acF s rnowavailable:r_2 countries The NeGfJ'=';premgu_hSongXz NeONj,P:eON -,":eCN�2 Bi;aual won:he`lntersolar AWARD`:n'013,2015 and 2016,vwh:cn demonstrates I.G's:eadersh:p and innovation:n the solar industry Llfds Good LG NeONOR LG375Q1 C-V5 General Data Electrical Properties(STC*) Cell Properties(MateriaVrype) Monocrystalline/N-type Model LG375Q1C-V5 ._..._........_.._...._..._..._...__.._......................._............_.._....._........................................... Cell Maker ( ) l ] ............__....... 375............_..................................__......... ................................................._LG_. ._Maximum Power Pmax W .................. ...................................._................................... ................................................ ........................_..............._.............,...._....._.................................................................._..................................................... Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) [V) , 37.2 ...................._..................._._.....____............_......._.....__............................................................................................................ .__.....—_._._.._.--._.._._._..._..._'---..........................................__.........._..._.._......................._......... _ Module Dimensions(L x W x H) 1,700mm x 1,016mm x 40mm MPP Current(Impp) [A] 10.09 ... . ................_......_....._..._.................---......................................................._................................._.........._.......... ...-................_..._........................................._._......_............................................................................................................... Weight 17.5 kg Open Circuit Voltage(Voc,±5%); [v) _ 42.8 ............................_............................I--......._..............._. ............................................................................................... _ Glass(Thickness/Material) 2.8mm/Tempered Glass with High Transmission Short Circuit Current(Is4t5%) [A] 10.83 Anti-Reflective Coating ....._................----..._._............................__....._.................................._............---..........................................._....................... ........_........................-............_._...._.._..............._..............................................................` (%J. Backsheet(Color) White Module Efficiency 21.7 Frame(Material) Anodized Alummium Power Tolerance _ [%] - p =3.._____-- _...__._....................-.-......._._......_-.__...........--.._................._.........................._........................................_..._......... Junction Box(Protection Degree) IP68 with 3 Bypass Diodes *STC(Standard Test Condition)Irradiance 1000 W/m',Cell temperature 25°C,AM 1.5 __...__...._......._.............-.._..........___...._.._.........._....;..._....................................................................................................... **Measure Tolerance:!3% Cables(Length) 1,000mm x 2EA .._._._.._..—_-- —.....-.....--____—._................._.__... Connector(Type/Maker) MC 4/MC Certifications and Warranty Operating Conditions IEC 61 21 5-1/-1-1/2:2016.IEC 61730-1/2.2016, OperatingTemperawre l [°C] -40-+90 ._...__......g Tem!-.-_---_-'_----�--.._..-�................_......._...__........................---._......._...... . UL 1703 Maximum System Voltage l 1,000 --- Corti nations --.-.._......_.-__-.....------.... ..._ .-------........---...__._...._.....__.........._._..........---.................. ISO 9001,ISO 74001,ISO 50001 Maximum Series Fuse Rating [A] 20 OHSAS18001 _..._.__.-.........----........................... ............................................. Mechanical Test Load(Front) [P-a/psfJ 5,400/113 Salt Mist Corrosion Test IEC 61701:2012 Seventy 6 ........___.._._.__..............__._._._._.—...._-..._................................................_............................__..........._................... ---------------.._............._..._..___..................._....__...__.....................__................................................................................... Mechanical Test Load(Rear) ! [Pa/psfJ 4,000/83.5 AmmoniaCorrosion Test IEC 62716.2013 '-----.___..............-...—.__.._.-........._.._.'---.._......--.--..............-..........._........_._.._-....... ....___..__...._..__...__...._.._.-_..._..__..__...___._...__........._...................._........_...._...._...................._...._....._..__.._.. Mechanical Test Load 5,400Pa/4,000Pa based on IEC 61215-2 2016 Module Fire Performance Type 1(UL 1703) (Test Load-Design Load x Safety Factor(1.5)) —...--...--....--._.................-......-----'--.._.._.._.._..__...------..............._-...................... Fire Rating Class C(UL 790.ULC/ORD C 1703) --'--...._.____...._...._....______......_._..........._........_......-........-.................................................................................................. Product Warranty 25 Years ..----....._....._........................_.._..--'...............__.................._..............................................................._.................... Output Warranty of Pmax Linear Warranty* ............ .......... *Improved 1st year 98%,from 2-24th year:03%/year down.at 25th year:90.6% Packaging Configuration Number of Modules per Pallet - [EA] -^ 25 _........................._. ._ _................_.........__......_......_�...._. ..........i........._.............._..................................-----------........._--- Temperature Characteristics Number of Modules per 40ft HQ Container, [EA] 650 NMOT* [°C] 44 t 3 Packaging Box Dimensions(L x W x H) [mm] 1,750 x 1,120 x 1,221 Pmax [%PC] -0.30 Packaging Box Gross Weight [kc) 473 . .................._.....................__.._...........---,........... .._.........._.............................--..........---......._...........__. Voc [%/°C] -0.24 ....................-..........................._......_._...,._..........._......................................................._..........._.........._..........................._.. Isc _ [%/°C) 0.037 -NMOT(Nominal Module Operating Temperature)Irradiance 800 W/m',Ambient temperature 20°C, Wmd speed 1 m/s,Spectrum AM 1.5 Dimensions(mm/inch) Electrical Properties(NMOT)_ Model LG375Q 1C-VS .Maximum Power(Pmax) ! [W] I 282 - == _ l =.o MPP Voltage......... (vmpp) >` M . . ._...__...__....-'--...--3.7_...1. c . ............ ......._....._-._..j_........_.._...„ .................................__..................._...... ......................... MPP Current(ImPP) [A] 7.61 _....__--_.._......_.----..._ , _ Open Circuit Voltage(Voc) [V] 40.3 Short Circuit Current(Isc) [A] 8.72 I 1-V Curves I I ._____._...._..._._.._....._....-.................................._......_.... __.._ >.__............... .................................. A .., 4CVYv' i �•n tof:..--._V_. -`- —_..sv� Vnitu 'V) C5 Electronics,Inc. Product specifications are subject to chance without notice Solar Business Divine " LG 2000 hull iness:Drive LG37_`•Q':C-VS.pdf Lincolnshire,IL 600,69 Life's Good wv w.lg-seiarcom ©2020 LC Electronics,Inc.All rights reserved. ©+r+ ENPHASE. W, 777 7!P kL IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC Easy to install power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling a ase • u High productivity and reliability `5 • Produce power even when the year limited grid is down warranty- More than one million cumulative Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming CERTIFIED Complies with the latest L SAFETY advanced grid support , Connect PV modules quickly and easily to I08 Series Microinverters are UL Listed as Remote automatic updates for I08 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements I Q8S P-DS-0002-01-E N-US-2021-10-19 1Q'8 and IQ8+ Microinverters INPUT DATA(DC) 198-66-2-US ,: Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current=[module Isc) A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA(ACI 0• ., ,;. Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range3 V 240/211-264 Max continuous output current A 10 121 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit4 16 13 Total harmonic distortion <5% Overvoitage class AC port III AC port backfeed current mA 30 Power factor setting t.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 1 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range 400C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") I Weight 1.08 kg(2.38lbs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor ' CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at httpsJ/Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IOBSP-DS-0002-01-EN-US-2021-10-19 ®1- 00 - 'All The SnapNrack line of solar mounting systems is designed to reduce total '•-<':a's'- axe`>�; installation costs. The system featuresHIE- ` ` NM technical innovations proven on more £:° '� ' ° b:{ than 20OMW of solar projects to simplify = ` installation and reduce costs. Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an innovative gin solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps' shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1" slotted bolt connection • 1" spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www.snapnrack.com/contact Sna, 1 ' rack- Patent Pending A + I Flashed L Foot Kit Assembled(1'spacer sold seoarately) Flashed L Foot Kit Parts(1'spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions 7SNAPNRACK CHANNEL NUT .-SNAPNRACK 92 DEGREE L-FOOT,CLEAR -511615 FLANGE NUT � --5116-18X lIN 6OLT WTRt SPLIT LOCK WASHER -SNAPNPACK C0KIP0SITON FLASHING I 1 • I --SNAPNRACK L-FOOT BASE J------I� --J- SB SnapNrack Flashed Foot Technical Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship Snap". rack (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. i. . SERIES 100 .ROOF MOUNT SnapNrack •lar Mounting Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation - quality on more than 3S0 MW of solar = " Installations. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System ar ; _.h•a.-_,a:<. _ 7 is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 UL is Listed ` y"`-- - to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4,Simple Steps: i electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware. The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the - - "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof,Type, Wind and Snow Loads) the best in class installations in quality,safety,and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material fora single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required i • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail plit-Lock Washer P Bolt with Split- Splice Insert S �.� Lock Washer SnapNrack Bonding �' SnapNrack Adjustable End SnapNrack Splice Clamp Top Bonding Base Mid Clamp n • SnapNrack SnapNrack Bonding SnapNrack Bonding Adjustable End Stainless Clamp Bottom Bonding Stainless Hardware with Bolt with Channel Nut Channel Nut Split-Lock Washers Split Lock SnapNrack Bonding Washer Adjustable End Clamp SnapNrack Bonding SnapNrack Bonding Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF s �� •�' MODULES) s � SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap rry UEC Wedge Stainless Steel Bolt �'•�"�'"�� ."��"'rr�+a..r,..`���'�"' with Flat Washer ® SnapNrack Bonding Universal End Clamp SnapNrack B onding Standoff Clamp Assembly SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack Stainless SnapNrack 92 Degree Flange Mill Finish L Foot Bolt Standoff o SnapNrack SnapNrack in All Purpose Mill Finish L Foot Standoff Base(1-Hole SnapNrack SnapNrack SnapNrack A Flas Metal Roof Base Shown) Mill Finish L Foot Base Assembly L Foot Flashing Base SnapNrack Bonding J SnapNrack Bonding SnapNrack Metal Standoff Assembly L Foot Base with Flashing Roof Base withBonding L Foot SnapNrack • • Technical Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) Snap rack- (877) 732-2860 www.SnapNrack.com r� Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved.