Loading...
HomeMy WebLinkAbout47559-Z �o�OS�FFa1 40, � Town of Southold 1/27/2024 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44902 Date: 1/27/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 8570 Nassau Point Rd, Cutchogue SCTM#: 473889 Sec/Block/Lot: 118.-5-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/16/2022 pursuant to which Building Permit No. 47559 dated 3/17/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Gray,Heath&Rhodes,Molly of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47559 12/29/2023 PLUMBERS CERTIFICATION DATED 0- A tho ize S gnature �,�uFEe TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY N T. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 47559 Date: 3/17/2022 Permission is hereby granted to: Gray, Heath 175 W 12th St Apt 18E New York, NY 10011 To: install generator as applied for. At premises located at: 8670 Nassau Point Rd, Cutchogue SCTM # 473889 Sec/Block/Lot# 118.-5-5 Pursuant to application dated 2/16/2022 and approved by the Building Inspector. To expire on 9/16/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $23 5.00 it spector pF SOUT��I 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 ae sean.devlina-town.southold.ny.us Southold,NY 11971-0959 D�yCOWNS�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Heath Gray Address: 8570 Nassau Point Rd city:Cutchogue st: NY zip: 11935 Building Permit#: 47559 Section: 118 Block: 5 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: G&S Electric License No: 578ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 300A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 38kW Kohler Generator w/ 300A Transfer Switch Notes: Generator Inspector Signature: .Date: December 29, 2023 S.Devlin-Cert Electrical Compliance Form so(/ThO� 47s5 8 -70 /VriTia f '�' Rd # # TOWN OF d SOUTHOLD BUILDING DEPT. °`ycourme�' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: (f lea AAC-e1-124�fA lcvk . isw w ,, 177atk P# 4Y 711"elICA Q-�Z -/ Iit�tJ ' p ,04 U4:—0,e- 0 Q2 � DATE INSPECTOR SOUlyolo # # TOWN OF SOUTHOLD BUILDING DEPT. `ycou 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAU KING [ ] FRAMING /STRAPPING [ FINAL 6 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ✓ re foks— VI c vvl CA l ' DATE INSPECTO k Al �1 y �s7s r vap — t- .1� AL� y T� 1 � r ��sl � �• �L V r � i I L ��. f"F,; 'fir '•• t�S; n 1 - v M e •tlIIYM'�=. Y1t"' gy�yyer. mienwr,.^ ,. i r i Ali4 Too 77 7.0 as } 3 i r FIELD•IN PE :::.;>ram•• ,: ,a:;:,,, 'C tit FOUND ATION: 1 ST :FOUNDATION'..' rA ",?j;':;:..�.i';t�:.it a:,.{2r )..,�io4.:�•,.ak., r•'! t. j w.l e:q.tii:�SYi�;:wr:.�;,.+.,�-1';':t?':�Y,_,.�.��t•�:�.�•„;:.;': . ° `'I!`;:'rk �:'• '' ^;uFi,,�,,.ti i.lyr,ii: '7�4: :�l ri$e'r.`:`�'i;�.•..;. ;"• ROUGH E & •UIVIBAV.G. :.. �.. 31 Ld — ,rx fl: ..t. t. „+1. ' � , `�t���.�r `i15.`4:Tr�-,•�.v<Y.•.tii7,i,i);'� • INSULATION, SRN.' STATE ENERGY C-CSD 'r- :;t:=<.; ',•,:i- , -:' 5ir�;.. Cyr; .�r..:•Nr, :).:.a.:"',� , FINAL 9:.i'..' 4j:,':� `r'f•:'sti:ll�!,.ti::jil,'rti:. •5 .. MM .. ,i '.T. ,k',�"?.mr`t��r:,l:ri5J1 R`{:•„.Y•�•t,��:.:'� GZ :, :� {':. ire:';...''''1.�?• U ' � a - C+�'r ,j�. ,a+i'(•�tiad�icjaK;..�n,r�rl:.`ii;j•;;;..: .. ::idi ".`'S�2sJe.' :�-y'n+i:�''y�1•Ka,x p��'f� ... � .. �o�SUFFa(KcoGy TOWN OF SOUTHOLD—BUILDING DEPARTMENT cc Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 hi!ps://www.southoldtom=.Ro Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. �J Building Inspector: F E B 1 6 2022 Applications and foams must=be;filled.out,in°fheir,entirety.Incomplete .. ., applications vuill�not be accepted.,46re the Applicant is n'ot the owner,an Owner's Authorization form(Page 21shall be completed. Date: OWNER(S).OF'PROPERTY: _ 5-7t) Name: `` SCTM#1000- Project Address: 'j�® �� Phone#: tj.'� Email: '"� "'� Mailing Address: CONTACT�PERSON::. ..._,... Name: Mailing Address: .1.._�i�_.�M.�_...-_`�1�J .__��._�•-'' _�(,�1.� __I�I�,__�V���•O ____�. �_.....d.__.._.,..._, � r1. -55r__.....__._.,.._.__.__.- — Phone#: Email• ,, � , ' • ' DESIGN:PROFESSIONAL INFORMATION: . Name: Mailing Address: Phone#: ��) "� .�� � Email: ,CONTRACTTOR:IN FORMATION:' Name: Mailing Address: Ck �/ Phone#: Email' (`u(�L�,_G1��cCD_1V1...._.�.._. ,DES CRIPTION 0F'PROPOSED`CONSTRUCTION`.=. 4m. T-... ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ,'other (5 � $ ey. Will the lot be re-graded? ❑Yesy to Z Will excess fill be removed from premises? ❑Yes);Oo 1 PROPERTY INFORMATION g p �j"� ` Intended use of roe G Existin use of roperly:� y` 4 i P P rty Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this properly? ❑Ye�<o IF YES,PROVIDE A COPY_ ❑Check BOX After Reading: The owner/contactor/design professional is responsible for all drainage and stone water issues as provided by chapter 236 of the Town Code.APPLICATION LS HEREBY MADE to the Building Department fbrthe issuance oFa Building Permit pursuant to the Building zone Ordinance of the Town ofsouthold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings. addhtiors,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, horsing code and regulations and to admit authmiwd inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Mass A misdemeanor putsuatttto Section 2M.45 of the New York State Penal law. Application Submitted By(phi name authorized agent ❑Owner Signature of Applicant: ! JJf� Dater V '/ STATE OF NEW YORK) f SS: COUNTYOF p ) MW Puy, L�i� being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the i+ <Qt i CAS{4 � (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this aday of Ll '6 ,2022, PNotary Pub It PROPERTY OWNER AUTHORIZATION ��oGG�5°o1S� (Where the applicant is not the owner) o-•,:.•:�a;:s,•,o�:�, v 2 i 7yC:.7T.5S:C'i x;r. C.C.13.2J 1'. A PY c S'?L ('J--XAY residing at 315 0 A,BMA; 1 S.r do hereby authorize ' /(? Q P�faY L(/C�4 to apply on my behalf to the Town of Southold Building Department for approval as described herein. 6,3 Z/g6�,70;? R- Owner's Signature Date #e,qT At 4°-R'4 Y Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector 'PG . TOWN OF SOUTHOLD o. Town Hall Annex- 54375 Main Road - PO Box 1179 . Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ' rogerr@southoldtownny.gov- seand(&-southoidtownny.gov_ APPLICATION FOR ELECTRICAL INSPECTION LECTRICh .-I.NFORMATION (Au information Required) Date: / 3 zaa Company Name: 627 it .( 4-- 1-Z-t L Electrician's Name: . G C-11R r2l zg�"t ..4, co License No.: t5 7 p Iq Elec. email: GS 16 Elec. Phone.No: S/6 d% Sj I c :191 'request an.email copy of Certificate of Compliance Elec. Address.: JO SITE INFO ON (All Information Required) 'Name:. S lz4y Address; 3 '0.. P.3.02� LA.J� igS /1/ `man Cross Street: Phone No.! B1dg.Permit#: S email: Tax Map.Dis#rict:. . 1-000 Section: 1FK Block: BRIEF DESOR1PT10 1'-OF-WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): C -3 ,�:i J Square:Footage: .C 1r.*i41i- 1y: Is.job.ready for.iris ecttori?: YES, NO Rough In Final Do you need:a Temp Certificate?: YES NO Issued On Te> p.tnt<oi tio>fi: (A] Wormatiost required) Service.Size T Ph 3.Ph Size:. . A #Meters.. Old.Meter# .New Service Fire Reconnect Flood.Reconnect-Service Reconnected Underground- Overttead #.lJnd.tground.:Laterals 1 2 H Frame Pole Work done on Service? Y N A�itiar�aiirxforr�a#inn: . FAR YM - - - APP E LL IIn NOV 2022 BUILDING DEPARTMENT=Electrical Inspector O : G TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 . �,;::, • Southold, New York 1.1971-0959 _ Telephone (631) 765-1802 - FAX (631) 765-9502 ' rogeE@southoldtownny.gov seand0southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION .LECTRtCIAWINFORMATiON (Au wormabon Required) Date: Company Name: Electrician's Name:. . .G r1R 2/ Z;F.t-� n License No.: .S.z p.✓mil!!5. Elee. email: Elec. Phone.No:. , i c :9 I.request an.email.copy of Certificate of Compliance._ Elec. Address.: C}B::SI' f' NI=QIATtfll (All�r�formation Requi(ed) Name:. G'. .- eq Address:' 3 5 o A;3.0 2^i GA r S70" a n Cross S#reet: Phone No: ' Bldg.Perrnit#: S email! Tax. lYlap:E?strict;.. 1 000 S.etion:. . _ . . Block: Lot: BRfEf t3S. '.. CR#i?TICll C3F:14lZK; INCLUDE SQUARE FOOTAGE,(Please Print Elearly): ,.eie:Ai 1 ob.:read�t foc.iris.0000. YES 0� Rough In Final Do you.reed;a hemp Certificate?: YE S NO Issued On .(Alit fi (fri. qn required) Tet�p trt�o ,tartio�:. .. o $erviGe Size T Ph ' -3 Ph Size: A #Meter ... Old:Meter#. Mew Service. Fire Reconnect Floes;Reconnect Service Reconnected Underground.-Over Undeci rourid,Laterals f 2 H Frame . , Pole Work--,done on-Service? Y N Ada ­lrt€oaiori PA M NOV 0 2 2022 ' ' FREDERICK ROBERT WEBER ARCHITECT W a r , r m 0 rT, RAMP WALK • ' �\v LOT 102 r� co ^ � rn � � EXISTING �/ 1 \Y I I I 1 yS 8603, 1QQ11 E '�� °°°' FRAME GARAGE r (� \\\ MON. I I I / I 04 N N -19"x A'N I ° I / 119.36' / N aN N i// / 1 26.4' 6'FFN293. 151 3. 1 51 O pry+ ++ OPT `CJ 1 y I ( 1 ' K /� -—- --1 �FFF1�R SEMENT / I / 1.1'S CF J ry ti /yo -24'x F� °9 I 1 I i / -- i / T` / v �. MON. 3 ) � I SH ON PREVIO S w` ,-/ O1 r x-13" �� / I TIDAL WETLAND BOUNDARY ' I I // �� S 0 )- ' 2.6'S 1 AS DELINEATED BY ( I 1 1 1 1 - yRVEY B J. INGEG r I f REMOVE ` -25"'x yo 4r a 1 06' - 'OCT. 19, 1994 z EN-CONSULTANTS / "L —I — % N 1 /�0 11 2 �J EXISTING ` O� I U.P. �Q / ,�- 09-Oz-19 / I o 1 r --T _ 1 r , ��. SHED \ .a / / I S 1 �:. 1 l — --1-- — 4-- _ _ _ _� —— / 1 z.2' 1 0 1N io° -r^ `03 M 1 — = REM VE - r--1 I \®! 3 - r _ DECK _ — A I W 1 uj /Wbo g �o , / 1 [ .. 7'>•,.,` - •REMOVE EXISTIN 1 �� 50'-0" 1 �� SSE o° T p/ /S STONE DRIVEWAY i o` �� i B :e ;. AC Units�, �b �� off° �/ � ,n"\, \X' �? i .. (3:x9'). .. • '' � (Pnm�ry Fronts 1 s S 4 1 -- \ __ m ° o P / T / h REMOVE E- NNG I I O o �6 IrTI °'C� , I x STONE DRIVEWAY ��/ '\�� .\ /0 PROP O \ I 0 1I I Z DRAWING TITLE:tt i I S ogKPILE I \ N I ..... .. ,/ //Xt 0• / 1. / Contr�l;.� C ���//' �.' 1` �. (Replace Cur SITE PLAN / / i ,:- / off,•o oo°° P / 0 5 j �oz O h // ^, N-----' I / \\` IPont R d u D 0 ti s / ParreT '� I J )Along O GENERATOR A,ZP /i �� ,JQ ryO' ��� v� �0 Blower x �> , �i�," y�4 -J/A-_WTS. ` `� r �' ; THE �1-Ei�1'T / 1� 1 Sow_ _----�� opO°. ; �� �/ ,��o ��vx �,G. �/ TANK \ poaoa om / / �^ ,G // U �ioo oa0000aoo \ / DB Q N'* EXjj55'ING STONE D�NEWAY P� G� 1� \ / • � / / � _ � :__- ,, , > • ../•. .. �, � � ��`������ � � JOB: GRAY LOT 101 U.P. RESIDENCE Stone \0 �G QO ���Q�o . 350 ABORN LANE/ 'Stone IN Abandon F� 8510 NA55AU POINT RD Stoop i6, a Existing / CUTCHOGUE. NY Septic ank / PROPERTY OWNER: TOWN OF Q� ) eaching -Er�l9' HEATH GRAY t MOLLY RHODES SCTM# 1000u8 OS 05 N°` ` Outdoo - "' 1y� r � ��-' ��` �` SITUATE: CUTCHOGUE (NASSAU POINT) / TOWN OF SOUTHOLD _. /�i \\.�r ''• Show .,• a�_ �; �� �.,�1\\,L� 1\ ,NEW ASPHALT �� /-' G ARCHITECT: b I� , DRIVEWAY Existing / �� SUFFOLK COUNTY, NEW PORK - / Test Hole °� SURVEY INFORMATION: i FREDERICK R. WEBER LE ROAD \, :. • _ `� / ��� - KENNETH WOYCHUK 41/ \ """" 1\ p/I/ `; AQUEBOGUE, NY GR ENLAWNPNY 11140 Pt� SURVEYED: AUGUST 14, 2018 �� -,,, d ��6e, ��O`' LAST REVISED: SEPTEMBER '4, 2018 52 NOYAC PATH i ®E1 / coNCR rE -„ 'l Qj\° +O.O' = ELEVATIONS REFERENCED TO NAVD of 1988 WATER MILL, NY 11914 AREA-OUT � �� e� ��p•(� / El +19.2 _ \� LOT 99 °--"� \L NEW ASPHA 1 / / So Existing �� 0e SCTM# 1000-118-05-05 TEL 431 154-5555 Water Tap DRIVEWAY rr F` I, LOT AREA. 46.422 S.F. fweberarchitectegahoo.com •'�� WETLANDS AREA: 2161 S.F. BUILDABLE LAND: 44,255 S.F. (±) 5EA \r-K ZONING: R40 1�^ '•:A� (a / YARDS: (PRINCIPAL SETBACKS) PROPOSED New ! FRONT (Primary): 50' Meter I i} FRONT (Secondary): 35' �'a` `- GENERATOR <1 Frame 1 �v °� SIDE (ONE): 15' E6•I R20 100011\Gal. Existl.iag • sae � SIDE (BOTH): 35' JULY tS 2021 Propaha, T-ank Utility 0 `� \°� REAR: 50' JUNE 22, 2021 (Buried)•..\ :P'ole �" Nee\o;'�� LOT COVERAGE (ALLOWED): 20% (MAX.) APR 5, 2021 S MAR 8, 2021 HOUSE: 2894 SF DEC 28, 2020 GARAGE: 119 SF I/A, Non- FRONT PORCH: 114 SF Disturb NOV 2. 2020 REAR/ SCREEN PORCH: 188 SF OCT 2. 2020 P�oS°PJ�°� TOTAL: AUG. 11, 2020 4575 SF REV.: AUG. 4, 2020 LOT COVERAGE (PROPOSED): 10.3% DATE: JULY 21, 2020 YARDS: (ACCESSORY SETBACKS) 5CALE: In - 20' (LOT SIZE: 40,000 TO 59,999 SF) SIDE t REAR SETBACK: 15' JOB NO: w201901 FRONT (Water Front/Primary): 50' S ITE NORTH FRONT (WaterFront/Secondary): 35' MAXIMUM HEIGHT: 22' DRAWING NO. 1" = 20'-0" MAXIMUM AREA: 1200 SF' (LOT SIZE: 20,000 TO 60,000 SF) 8 EXISTING CONTOUR Al 8 ......... OLD CONTOUR 8 NEW CONTOUR OF A9 APPROVED AS NOTED DATE:� P.# FEE: BY: NOT BUILDING DEPARTMENT AT 765-1862 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: I. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF S ._ T WN PLANNI ARD SG�L R TEES 'JCCUP}ANCY OR USE IS UNLAWFUL WITHOUT CERTIFICL, - )F OCCUPANCY ELECTRICAL INSPECTION REQUIRED i KOHLER. Model: 38RCLC Multi-Fuel Natural Gas/LPG 09001 Standard Features IL KOHLEIL • Kohler Co.provides one-source responsibility for the NATIONALLY REGISTERED generating system and accessories. • The generator set and its components are prototype-tested, factory-built,and production-tested. - • The generator set accepts rated load in one step. • A standard five-year or 2000 hour limited warranty covers all systems and components. +: =-== 1 • Quick-ship(QS) models with selected features are available. ^;r r;a-:•t:, Fa.x ;, See your Kohler distributor for details. Meets 291 kph.(181 mph)wind load rating. • GFCI service outlet installed on the junction box. • RDC2 Controller o One digital controller manages both the generator set and transfer switch functions(with optional Model RXT transfer switch). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying household demand. The Kohler® Advantage o Digital voltage regulation protects your valuable • High Quality Power electronics from harmonic distortion and unstable power Kohler home generators provide advanced voltage and quality. frequency regulation along with ultra-low levels of o Two-line,backlit LCD screen is easy to read in all lighting harmonic distortion for excellent generator power quality to conditions,including direct sunlight and low light. protect your valuable electronics. • Engine Features o Powerful and reliable 2.2 L turbocharged liquid-cooled • Extraordinary Reliability engine Kohler is known for extraordinary reliability and o Electronic engine management system. performance and backs that up with a premium five-year or o Simple field conversion between natural gas and LPG 2000 hour limited warranty. fuels while maintaining emission certification. • Aluminum Enclosure • Innovative Cooling System Attractive aluminum enclosure allows installation as close o Electronically controlled fan speeds minimize generator as 18 inches from your home or small business. set sound signature.• Certifications • Quiet Operation o The 60 Hz generator set engine is certified by the Kohler home generators provide quiet,neighborhood- Environmental Protection Agency(EPA)to conform to the friendly performance. New Source Performance Standard(NSPS)for stationary spark-ignited emissions. o cUL/UL listing,GSA,certification standard are available (60 Hz only). o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. o Meets NFPA 37 requirements for 18 in.offset for installation. • Approved for stationary standby applications in locations Generator Set Ratings • served by a reliable utility source. Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kw/kVA Amps kW/kVA Amps 4E8.3 120/240 1 60 38/38 159 38/38 159 120/240 1 60 34/34 142 34/34 142 120/208 - 3 60 38/48 132 38/48 132 4D8.3 127/220 3 60 38148 125 38/48 125 120/240 3 60 38/48 114 38/48 114 2771480 3 60 38/48 57 38/48 57 ` 50 Hz options available.Contact your Customer Service representative. RATINGS:Ali three-phase units are rated at 0.8 power facW.All single-phase units are rated at 1.0 power factor.Due to manufacturing variations,the ratings tolerance is=5%. Standby Ratings:Standby ratings apply to Installations served by a reliable utility source.The standby rafing Is applicable to varying loads with an average load factor of 80%for the duration of a power outage.No overload rapacity is specified for this rating.Ratings are In accordance with IS0,3046M.8S 5514.AS 2M,and DIN 6271.GENERAL GUIDEUNES FOR DERATING:Atltude.,Derate 1.31A per 100 m(328 it)elevation above 200 m(656 t).Tempe�Derate 3.0%per 1o°C(1 a°F)temperature above 25°C(77°F).Availability Is sub)ect to change without notice.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.Contact your local Kohler generator distributor for availability, G4-305 (38RCLC) 6/21 Alternator Specifications Specifications Altemator • NEMA MG1, IEEE,and ANSI standards compliance for Manufacturer Kohler temperature rise and motor starting. Exciter type Brushless,Wound-Field • Sustained short-circuit current of up to 300%of the rated Leads:quantity,type current for up to 10 seconds. 4E8.3 4,120/240 4D8.3 12,Reconnectable • Sustained short-circuit current enabling downstream circuit Voltage regulator Solid State,Volts/Hz breakers to trip without collapsing the alternator field. Material Class H e Self-ventilated and drip-proof construction. Temperature rise 130°C,Standby Bearing:quantity,type 1,Sealed • Windings are vacuum-impregnated with epoxy varnish for Coupling Flexible Disc dependability and long life. Unbalanced load capability 100%of Rated Standby Current • Superior voltage waveform from a two-thirds pitch stator and One-step load acceptance 100%of Rating skewed rotor. Peak motor starting kVA: (35%dip for voltages below) e Total harmonic distortion (THO)from no load to full load with 240 V 4E8.3(4 lead) 74 (60 Hz) a linear load is less than 4%. 480 V,380 V 4D8.3(12 lead) 120(60Hz) 88(50Hz) Application Data Engine Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type Residential Powertrain Exhaust temperature at rated kW,dry KG2204T,2.2 L,4-Cycle exhaust,°C(IF) 633(1171) Turbocharged Maximum allowable back pressure, Cylinder arrangement In-line 4 kPa(in.Hg) 7,5(2,2) Displacement,L(cu.in.) 2.2(134.25) Bore and stroke,mm(in.) 91 x 86(3.5 x 3.4) Fuel Compression ratio 10.5:1 Fuel System Piston speed,m/min.(ft./min.) 310(1016) 258(847) Main bearings:quantity,type 5,plain alloy steel Fuel type Natural Gas or LPG Rated rpm 1800 1500 Fuel supply line inlet 1 in.NPT Max,power at rated rpm,kW(HP) Natural gas fuel supply pressure,kPa LPG 47.8(64.1) NA (in.H2O) 1.2-2.7(5-11) Natural Gas 47.6(63.9) NA LPG vapor withdrawal fuel supply Cylinder head material Cast Iron pressure,kPa(in.H2O) 1.2-2.7(5-11) Piston type and material High Silicon Aluminum Fuel Composition Limits* Nat.Gas LP Gas Crankshaft material Nodular Iron Methane,%by volume 90 min. — Valve(exhaust)material Forged Steel Ethane,%by volume 4.0 max. — Governor type Electronic Propane,%by volume 1.0 max. 85 min. Frequency regulation,no-load to Propene,%by volume 0.1 max. 5.0 max. full-load Isochronous C4 and higher,%by volume 0.3 max. 2.5 max. Frequency regulation,steady state t1.0% Sulfur,ppm mass 25 max. Frequency Fixed Lower heating value, Air cleaner type Dry MJ/m3(Btu/fts),min. 33.2(890) 84.2(2260) Engine Electrical Fuels with other compositions may be acceptable.If your fuel is outside the listed specifications,contact your local distributor for Engine Electrical System further analysis and advice. Ignition system Electronic Lubrication Battery charging alternator. Ground(negative/positive) Negative Lubricating System Volts(DC) 14 Type Full Pressure Ampere rating 90 Oil pan capacity,L(qt.)§ 4.2(4.4) Starter motor rated voltage(DC) 12 Oil added during oil change(on average), Battery,recommended rating for-18°C(0°F): L(qt.)§ 3.3(3.5) Oty.,cold cranking amps(CCA) One,630 Oil filter:quantity,type§ 1,Cartridge Battery voltage(DC) 12 Oil cooler Remote Battery group size 24 § Kohler recommends the use of Kohler Genuine oil and filters. G4305 (36RCLC)6121 Application Data Cooling RDC2 Controller Radiator System 60 Hz 50 Hz Ambient temperature,°C(°F) 45(113) Engine jacket water"capacity,L(gal.) 2.65(0.7) Radiator system capacity,including vuoayn: zoo v Froq: 60.0 N2 engine,L(gal.) 13.2(3.5) Water pump type Centrifugal o 0 0 Fan diameter,mm(in.) qty.3 @ 406(16) 9)9 3 Fan power requirements(powered by ® W AM M engine battery charging alternator) 12VDC,18 amps each Operation Requirements Air Requirements 60 Hz 50 Hz The RDC2 controller provides integrated control for the Radiator-cooled cooling air, generator set,KohlerG Model RXT transfer switch, m3/min.(sofm)t 51 (1800) 51 (1800) programmable interface module(PIM),and load management. Combustion air,m3/min.(cfm) 2.1 (74) 1.8(64) Air over engine,m3/min.(cfm) 25(900) 25(900) The RDC2 controller's 2-line LCD screen displays status Air density=1.20 kg/m3(0.075 Ibm/ft3) messages and system settings that are clear and easy to read, Fuel Consumption even in direct sunlight or low light. Natural Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz RDC2 Controller Features 100% 13.9 (492) 11.6 (409) • Membrane keypad 75% 11.4 (404) 9.5 (335) 50% 9.3 (327) 7.8 (275) o OFF,AUTO,and RUN push buttons 25% 5.8 (205) 4.8 (169) o Select and arrow buttons for access to system Exercise 3.4 (121) 2.8 (99) configuration and adjustment menus LP Gas,0/hr.(cfh)at%load 60 Hz 50 Hz • LED indicators for OFF,AUTO,and RUN modes 100% 5.6 (197) 4.7 (166) • LED indicators for utility power and generator set source 75% 4.5 (160) 3.8 (134) availability and ATS position(Model RXT transfer switch 50% 3.2 (114) 2.7 (95) required) 25% 2.1 (75) 1.8 (64) • LCD screen Exercise 1.2 (413 1.0 (35) o Two lines x 16 characters per line Nominal Fuel Rating: Natural gas,37 MJ/m (1000 Btu/ft3) o Backlit display with adjustable contrast for excellent LP Vapor,93 MJ/m3(2500 Btu/ft3) visibility in all lighting conditions LP vapor conversion factors: • Scrolling system status display 8.58 ft.3=1 lb. 9 Y p Y 0.535 m3=1 kg. o Generator set status 36.39 fL3=1 gal. o Voltage and frequency o Engine temperature Sound Enclosure Features o Oil pressure • Sound-attenuating enclosure uses acoustic insulation that o Battery voltage meets UL94 HF1 flammability classification and repels o Engine runtime hours moisture absorption. • Date and time displays • Internally mounted critical silencer. • Smart engine cooldown senses engine temperature • Skid-mounted,aluminum construction with two removable • Digital isochronous governor to maintain steady-state speed access panels. at all loads • Fade-,scratch-,and corrosion-resistant Kohlere cashmere • Digital voltage regulation: ±1.0%RMS no-load to full-load powder-baked finish. • Automatic start with programmed cranking cycle Sound Data • Programmable exerciser can be set to start automatically on any future day and time,and to run every week or every two Model 38RCLC 8 point logarithmic average sound levels are weeks 53 dB(A) during weekly engine exercise and 61 dB(A)during • Exercise modes full-speed generator diagnostics and normal operation. For o Unloaded exercise with complete system diagnostics comparison to competitor ratings,the lowest point sound levels o Unloaded full-speed exercise are 52 dB(A)and 59 dB(A) respectively* o Loaded full-speed exercise(Model RXT ATS required) All sound levels are measured at 7 meters with no load. • Front-access mini USB connector for SiteTech'connection Lowest of 8 points measured around the generator.Sound levels at other points • Integral Ethernet connector for Kohler©OnCue�Plus around generator may vary depending on installation parameters. g • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-305 (38RCLC) 6/21 KOHL KOHLER® Phone 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet'in the US and Canada,phone 1-800-544-2444 KOHLERPoweccom Additional RDC2 Controller Features Available Options, Continued • Diagnostic messages Starting aids§ o Displays diagnostic messages for the engine,generator, ❑ Block Heater,120 V,1 Ph Model RXT transfer switch,programmable interface ❑ Block Heater,240 V,1 Ph module(PIM),and load management device ❑ Oil Pan Heater,120 V,1 Ph o Over 70 diagnostic messages can be displayed ❑ Oil Pan Heater,240.V,1 Ph • Mairitenance'reminders § One block heater or oil pan heater is recommended for ambient • System settings temperatures below 0'C(32'F). At temperatures below-18'C(0'F). o System voltage,frequency,and phase installation of both heaters is recommended. o Voltage adjustment Automatic Transfer Switches and Accessories o Measurement system,English or metric ❑ Model RDT Automatic Transfer Switch • ATS status(Model RXT ATS required) ❑ Model RXT Automatic Transfer Switch o Source availability ❑ Model RXT Automatic Transfer Switch with Combined o ATS position (normal/utility or emergency/generator) Interface/Load Management Board o Source voltage and frequency ❑ Load Shed Fit for RDT or RXT • ATS control(Model RXT ATS required) ❑ Power Relay Modules(use up to 4 relay modules for each o Source voltage and frequency settings load management device) o Engine start time delay Maintenance o Transfer time.delays ❑ Maintenance kit(includes air filter,oil,oil filter,and spark plugs) o Fixed pickup and.dropout settings Miscellaneous o Voltage calibration ❑ Rated Power Factor Testing • Programmable interface module(PIM)status displays Literature o Input status(active/inactive) ❑ General Maintenance Literature Fit o Output status(active/inactive) ❑ Overhaul Literature Kd • Load control menus ❑ Production Literature Kit o Load status Warranty o Test function ❑ Extended 5-Year/2000 Hour Comprehensive Limited Warranty Generator Set Standard Features ❑ Extended 10-Year/2000 Hour Comprehensive Limited Warranty • Aluminum sound enclosure with enclosed silencer • Battery rack and cables Dimensions and Weights • cUL/US listed,CSA certified Overall Size,L x W x H,mm(in.): 1880 x 836 x 1169 • Electronic,isochronous governor (74 x 32.9 x 46.0) • Flexible fuel line Shipping Weight,wet,kg Ob.): 621 (1370) • Gas.fuel system(includes fuel mixer,electronic secondary Weight includes generator set with engine fluids, sound enclosure, gas regulator,two gas solenoid valves,and flexible fuel line silencer,and packaging. between the engine and the skid-mounted fuel system components) • GFCI service outlet,120/240 V for customer connection • Integral vibration isolation • Line circuit breaker H • NEC prime mover shutdown switch • Oil drain extension • OnCue®Plus Generator Management System r—W� L .� • Operation and installation literature •, RDC2 controller with built-in battery charger NOTE:This drawing is provided for reference only and should not be • Standard five-year or 2000 hour limited,warranty used for planning installation.Contact your local distributor for more detailed information. Available Options DISTRIBUTED BY: Controller Accessories ❑ Lockable Emergency Stop(lockout/tagout) ❑ Programmable-Interface Module(PIM) (provides 2 digital inputs and 6.relay outputs) Electrical System ❑ Battery ❑ Battery Heater ❑ OnCue®Plus Wireless Radio Kit O 2021 Kohler Co.All rights reserved G4305 (WRCLQ 6/21