Loading...
HomeMy WebLinkAbout50026-Z �o��g�FFO Town of Southold 1/24/2024 0 P.O.Box 1179 C9 ��{ 53095 Main Rd Southold,New York 11971 r� CERTIFICATE OF OCCUPANCY No: 44889 Date: 1/24/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 4505 Route 25,Laurel SCTM#: 473889 Sec/Block/Lot: 125.-1-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/22/2023 pursuant to which Building Permit No. 50026 dated 11/15/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to an existing single-family dwelling as applied for. The certificate is issued to Bokina,Adeline of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL . ELECTRICAL CERTIFICATE NO. 50026 12/20/2023 PLUMBERS CERTIFICATION DATED 'If I ut orize ignature o4oS�fFQ"� la TOWN OF SOUTHOLD BUILDING DEPARTMENT h x TOWN CLERK'S OFFICE o . t SOUTHOLD, NY 0 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50026 Date: 11/15/2023 Permission is hereby granted to: Bokina, Adeline 4505 Route 25 Laurel, NY 11948 To: Install roof mounted solar panels to an existing single-family dwelling as applied for per manufacturers specifications. At premises located at: 4505 Route 25, Laurel SCTM # 473889 Sec/Block/Lot# 125.-1-11 Pursuant to application dated 9/22/2023 and approved by the Building Inspector. To expire on 5/16/2025. Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 ELECTRIC $125.00 Total: $325.00 S'A �` J Building Inspector OF SO!/l�ol h O Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 Q sean.deviin(D-town.southold.ny.us Southold,NY 11971-0959couffm BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Adeline Bokina Address: 4505 Route 25 city,Laurel st: NY zip: 11948 Building Permit#: 50026 Section: 125 Block: 1 Lot: 11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52639ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Solar X Commerical Outdoor X 1 st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 petectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 19.44kW Roof Mounted PV Solar Energy System w/ (48) QcellQpeakG10-405W Modules, AC Combiner, AC Disconnect Notes: Solar Inspector Signature: Date: December 20, 2023 S.Devlin-Cert Electrical Compliance Form Of SOUryo� v V c _- * # TOWN OF SOUTHOLD BUILDING DEPT. �ycouto, 631-765-1802 INSPECTION '. [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [>PELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ] P C/O [ ] RENTAL REMARKS: Ll 11AAZZ- 1, 4/_ 01 r g,6 rf 1�4 DATE 2-3 INSPECTOR ���►/n o��OF SObIyO! —- ` h O # TOWN OF SOUTHOLD BUILDING DEPT. °`eno, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL�Olp.� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL RE R S: zloo"—�0A4 -Z 04 DATE Il ?' INSPECTOR - &WARNING - 111111T'1 � .�,/16�d1T 1FM1 OVo OR fnmo&To Ujou THIS SERVICE METER . IS ALSO SERVED BY A PHOTOVOLTAIC SYSTEM CAUTIONMILULI IS SERVICE IS ALSO SUPPLIEV FOLLOWIN•' OURCES WITH DUAL POWER SUPPLY ,AS SHOWN SOURCES, UTILITY GRID AND 1 PV SOLAR ELECTRIC SYSTEM ' x�c ooaon o �� o�aaoaao � o ,��oa$oaao ° • a_aoaap ° # f .� w... ate !` lliti'11111'�111' 1111111'I .4�'dl' �� 098346557 � t -FOCUS RXR-SD / e,.^•MORN 2$CLM 24ON]W 60Fa TA. :w, + UH34(15!->7 1 tlllltUlY1111mH oil MYA11 LONQ ISLAND POWER AUTHORITY V1\1;111Q111.111-NR1 M � Sooz� ° IURNWARNIN YIw,CX9M9CK OR THIS SERVICE METER IS ALSO SERVED BY A = PHOTOVOLTAIC SYSTEM DUAL POWER SUPPLY 1 SOURCES:UTILITY GRID AND . PV SOLAR ELECTRIC SYSTEM ' v a ie�'wn►�aeniiCnNx�r '� 098346557 1 11 _.-FOCUS R a• -FOUSR R-SD 1 YItlAP Y111Y11H YA 11111� wuc s.wo aow +.oun J FIELD INSPECTION REPORT DATE COMMENTS •o _ rn FOUNDATION (1ST) ------------------------------------ �� C FOUNDATION (2ND) O�rn � O O ROUGH FRAMING& PLUMBING � v` G �" r INSULATION PER N.Y. FSy STATE ENERGY CODE 1 FINAL ADDITIONAL COMMENTS 1 8 E - v 0 QZ rn t� ►d i 9..;p y JT) O z x - r� ! -3 � x d b H TOWN OF s®1JTHOLD —BUILDING DEPARTMENT ys Town ball Annex 54375 Main road P. ®. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https:l,Iwu,w.southoldto,,tinnv.gQv Date Received I APPLICATION FOR BUILDING PERMIT � For Office Use Only D PERMIT NO. 5 00 Cq(D Building Inspector: SEP 2 2 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. where the Applicant is not the owned-,an ®ullding Dopalrtmed � ®wnees Authorization form(Page 2p shall be completed. Town of Southold Date: OWNER(S)OF PROPERTY. Name:�l rl� �. �55 Ir'� SCTM#1000- �a 5,o� _ �'� 00 - 01� , O 0 0 Project Address: -f Is e S �(�►a R� Lk1.�,. it� � � (� �`�-� Phone#: I --7 -? ., Cl 93 Email: Fe-y'-Y-A & G� Mailing Address: �u 5 G— r—1 � ( u , I Q Lie CONTAC t PERSON- �U=I. -1 i Name: Mailing Address: 71- Phone#: a Z' Email: i P "S DESaGN PROFES OVAL INFORMATIO a Name: Mailing Address: ' Phone#: Email: CONTRACTOR INFORMATION.- Name: Mailing Address: ' dam +:) )L, 1 L C1vt-, ` 6�t-4 ' 4ac N."Li. I.� cy Phone#: � ' ,,/ . Email: DESCRI10 ON OF-PROPOSE D CONST3i;QDcnm ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: [ Other - T Will the lot be re-graded? ❑Yes_NO Will excess fill be removed from premises? ❑Yes o I s '.� 8 v'L'� 'u e.✓=Y' � ! ...'L1.,f .r'L'-L .a d'�..''� Y— 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes-�Ao IF YES, PROVIDE A COPY. ❑.check Box After Reading: The owner/contractor/design professional,is responsible for all drainage.and storm water issues as provided by.. Chapter 236 of the Town Code. APPLIcATiON IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described,The applicant agrees to comply with ail applicable laws,ordinances;building code, . dousing code and regulations and to admit authorized inspectors on premises and in building(s)for,necessary inspections.False statements made herein,are punishable as a Class A misdemeanor,pursuant to Section 210.4S of the New York State Penal Law. Application Submitted By(print name): L-01�1�?�l f`n 2� 1�1 /'li�� , "WAuthorized Agent ❑Owner Signature of Applicant: 0 Date: STATE OF NEW YORK) SS: COUNTY OF Lo r IrOL,I P-e� ►. ��� l being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the 010 rL+1r1Ac,�u r-- (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this '02—day of s 4 , 20 Z Notar6lublic LOUIS J ROMEO Notary Public,State of New York No.01 R06314813 Qualified in Suffolk County PROPERTY OWNER AUTHORIZATION Commission Expires November 17,201/o (Where the applicant is not the owner) residing at ' V � Z . Ln do hereby authorize erz- tY t apply on my behalf to the Town of Sou Id Building Department for approval as described herein. -)� r q Owner's Signature Date ,b i o�neJ _ l� s6avw�- Print Owner's Name 2 ti 0�®UffOe�i,®� BUILDING DEPARTMENT- Vecctrical Inspector N TOWN OF SOU THOLD y x Town Hall Annex - 54375 MainRoad - P® fox 1179 Southold, New York 11971-0959 Telephone (631) 765-1302 - FAX (631) 765-9502 roge southoldtownny gov- sea ndP-southoldtownny gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) ®ate: Company (dame: Electrician's Name: � �1 . ^�� n�" License No.: ,�, � ��Y �� Elec. email: hV Elec. Phone 01 request an email copy of Cerdficate of Compliance Elec. Address.:'J Ll 17 0. DOB SITE INFORMATION (All Information Required) Name: j lit►'�e� ��56r�. �'d� i Address: 4 j S M CL i n Cuk U" AN-9 t Cross Street: Phone No.: 63 9 SIdg.Permit : 500a& email: Tax Map District: 1000 Section: Ja5 dock: I Lot: � BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Tease Print Clearly): d ' Square Footage: Cuu��cOce All That Apply.- Is job ready for inspection?: YES NO ❑Rough In Final Do you need a Temp, Certificate?: � YES NO Issued On Temp Ifformajtion. (All information required) Service Size01 PhF—]3 Ph Size: A #Meters Old Meter# E]New Service®Fire Reconnect[]Flood Reconnect®Service reconnect®Underground Doverhead # Underground Laterals R 1 2 H Frame Pole work done on Service? Y N Additional Information: -�,i a_s, �-,, rl,'c,�F C ZoJ P k>' PAYMENT DUE WITH APPLICATION .I,tom 9— — Form 8005-A(9/99)12-70.6M—Executor's Dtd—lo 4vidual or Corporation. (ainglc sheet) CONSULT YOUR LAWYER BEFORE SIONINO THIS INSTRUMENT—THIS INSTRUMENT SHOULD SE USED BY LAWYERS ONLY. 9 THIS INDENTURE,made the 27th day of November, 2000 and NO 14.Y.S. BETWEEN DIANE E. LESSARD, residing at 405 Mayflower Road, TRANSFER Mattituck, New York 11952, TAX STAMPS REQUIRED as executor of the last will and testament of Edmond A. Bokina a/k/a Edmond Bokina a/k/a Edmund Bokina - fate of who died oil the 17th day of October 2000 anlfSSurrogate's Court F Ileparty of the first part,and DIANE E. LESSARD, residing at 405 Mayflower Road, Mattituck, New York 11952, party of the second part, WITNESSETH, that whereas letters testamentary were issued to the party of the first part by the Surrogate's Court, Suffolk County;New York,on November 9, 2000 and by virtue of the power and authority given in and by said last will and testament,and/or by Article I I of the Estates,Powers and Trusts Law,and in consideration of partial distribution of estate pursuant to paragraph THIRD of Last Will and Testament of Edmond A. Bokina a/k/a Edmond Bokina a/k/a Edmund Bokina —daE+are- herey grant release unto the party of the second part,the distributees or successors and assigns of the padoeof the be and part! forever, rty ALL that certain plot,piece or parcel of land,with the buildings and improvements thereo rected,situate,lye g and being in the Hamlet of Laurel, Town of Southold, County of Suffonl�C and State 0�New York, bounded and described as follows: %11 BEGINNING at a point formed by the intersection of the northerly side of the Main Road leading from Riverhead to Greenport with the westerly line of land formerly of Herbert Conklin, late of Barrett, now of the Town of Southold; thence running along the northerly side of said Main Road, the following two courses and distances: (1) South 67' 34' 301, West, 10.99 feet; and (2) South 55, Os' 00"West, 204.01 feet to land now or formerly of Gilbert E. and Dorothy Wielt; thence along said last mentioned land, the following three courses and distances: (1) North 19- 07' 50" West, 400 feet; (2) North 55o 09, 00" East, 204.01 Eeet; (3) North 67° 341 301, East, 10.99 feet to the westerly line of land of the Town of Southold; and thence South 190 07' 50" East, along the last mentioned land 400 feet to the point or place of BEGINNING. SUBJECT TO AND RESERVING to ADELINE M. BOKINA, the exclusive possession and the use and occupancy of the above-described premises for and during the natural lifetime of Adeline M. Bokina, with the direction Adeline M. Bokina pay for all charges needed for maintenance of the property, including without limitation; real estate taxes, insurance premiums and all repairs and maintenance charges. i BEING AND INTENDED TO BE the same premises conveyed by deed dated December 15, 1966 and recorded in the Suffolk County Clerk's Office on December 16, 1966 in Liber 6087 Page 40. TOGETHER with all right,title and interest,if any,of the party of the first part in and to any streets and roads abutting the above described premises to the center lines thereof;TOGETHER with the appurtenances,and also all the estate therein,which the party of the first par(has or has power to convey or dispose of,whether individually,or by virtue of said will or otherwise;TO HAVE AND TO HOLD the premises herein granted unto the party of the second part,the distributees or successors and assigns of the party of the second part forever. AND the party of the first part covenants that the party of the first part has not done or suffered anything whereby the said premises have been encumbered in any way whatever,except as aforesaid. Subject to the trust fund provisions of section thirteen of the Lien Law, The word"party"shall be construed as if it read"parties"whenever the sense of this indenture so requires. 1N WITNESS WHEREOF,the party of the first part has duly executed this[Iced the day and year first above written. IN PRESENCE OF: Diane E. Lessard, Executor Acknowledgement taken in New York State Acknowledgement taken in New York State State of New York,County of Suffolk ss: State of New York,County of SS: On the 27thday of Novembepin the year 200Q before me, On the day of in the year before me, the undersigned,personally appeared the undersigned,personally appeared Diane E. Lessard 00 personally known to me or proved to me on the basis of personally known to me or proved to me on the basis of Q satisfactory evidence to be the individual(s) whose name(s-) is satisfactory evidence to be the individual(s) whose name(s) is cn (ere) subscribed to the within instrument and acknowledged to (are) subscribed to the within instrument and acknowledged to me that he/sheAey executed the same in ihts/her/their me that he/she/they executed the same in his/her/their capacity(ies), and that by this/her/their signature(s) on the capacity(ies), and that by his/her/their signature(s) on the Instrument,the individual(s) or the person upon behalf of which instrument, the individual(s) or the person upon behalf of which the individual(e)acted,executed the instrument. the individual(s)acted,executed the instrument. i Cr�7ci¢y— Notary Public THERESATHOMPSON ��ry�Stale Now York County ri0lr"h5I rl Ezp m Aug.13200]a Acknowledgement by Subscribing Witness taken In New York State Acknowledgement taken outside New York State State of New York,County of ss: 'State of County of ,ss: '(or insert District of Columbia,Territory,Possession or Foreign Country) tthhe undersigned,personally appeared e year before me, On the day of in the undersigned,personally appeared year before me, the subscribing witness to the foregoing instrument, with whom I am personally acquainted, who being by me duly sworn, did personally known to me or proved to me on the basis of depose and say,that he/she/they reside(s)in satisfactory evidence to be the individual(s) whose names) is that he/she/they know(s) (are) subscribed to the within instrument and acknowledged to to be the individual described in and who executed the me that he/she/they executed the same in his/her/their foregoing instrument;that said subscribing witness was capacity(ies), that by his/her/their signature(s) on the Present and saw said instrument, the individual(s) or the person upon behalf of which execute the same; and that said witness at the same time the i dualdmade such acted, executed the instrument, and that such subscribed his/her/their name(s)as a witness thereto. appearance before the undersigned in the (add the city or political subdivision and the state or country or other place the acknowledgement was taken). Title No.: SECTION 125.00 CK DIANE E. LESSARD, EXECUTOR, ESTATE LOT1.00 OF EDMOND A. BOKINA a/k/a EDMOND 011.000 BOKINA a/k/a EDMUND BOKINA COUNTYORTOWN of Southold TO STREETADDRESS 4505 Main Road DIANE E. LESSARD RETURN BY MAIL TO: Distributed by Chi'ago'Iltle Insurance Company Zip No. W U 0 O a 2 G [C ' O U W tL tL O W N Q O tt W U 6 N N us W • ' S Dear Taxpayer, Your satisfaction of mortgage has been filed in my office and I am enclosing the for your records. j If a portion of your monthly mortgage paymedt included your property taxes, you will now need to contact your local Town Tax Receiver so that youmav be.billed directly for all future property tax bills. Local property taxes are payable twice a year: on or before January 101h and on or before May 31". Failure to make payments in a timely fashion could result in a penalty. Please contact your local Town Tax Receiver with any questions regarding property tax payment. Babylon Town Receiver of Taxes Riverhead Town Receiver of Taxes 200 East Sunrise Highway 200 Howell Avenue North Lindenhurst,N.Y. 11757 Riverhead,N.Y. 11901 (516)957-3004 (516)727-3200 Brookhaven Town Receiver of Taxes Shelter Island Town Receiver of Taxes 250 East Main Street Shelter Island Town Hall Port Jefferson,N.Y. 11777 Shelter Island,N.Y. 11964 (516)473-0236 (516)749-3338 East Hampton Town Receiver of Taxes Smithtown Town Receiver of Taxes 300 Pantigo Place 99 West Main Street East Hampton,N.Y. 11937 Smithtown,N.Y. 11787 (516)324-2770 (516)360-7610 Huntington Town Receiver of Taxes Southampton Town Receiver of Taxes 100 Main Street 116 Hampton Road Huntington,N.Y. 11743 Southampton,N.Y. 11968 (516)351-3217 (516)283-6514 Islip Town Receiver of Taxes Southold Town Receiver of Taxes 40 Nassau Avenue 53095 Main Road Islip,N.Y.. 1,1751. Southold,N.Y. 11971 (516)224-5580 (516)765-1803 Sincerely, ' r � ���Utt�1CL�/• Edward P.Romaine Suffolk County Clerk dw 2/99 r Yoe I workers'STATE CERTIFICATE OF INSURANCE COVERAGE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carree 1a.Legal Name 8 Address of Insured(use street address only) 1 b.Business Telephone Number of insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured Work location of Insured(Onfyraquired ilcaverage is specrAcallylimited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 823336604 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"W SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/01/2023 to 1 213 1/20 24 4. Policy provides the following benefits: ® A Both disability and paid family leave benefits. HB.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By 4dug,4f (Signature of insurance carriees authorized representative or NYS Licensed Insurance Agent ofthat insurance parer) Telephone Number 516-829-8100 Name and Title Richard White, Chief Execuflye Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. 9 Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. it must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 6200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 4e,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By ISggnature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave beneM insurance porrcies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form D8-120,1.Insurance brokers are NOT authorized to issue this forme. pp i D8"120.1 (12-21) '`i16. � CERTIFICATE OF LIABILITY INSURANCE °ATE,M 7"'/1112 023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NCONTACT AME: ROBERT S.FEDE INSURANCE AGENCY PHONE - FAX 23 GREEN STREET,SUITE 102 No .OINC.No E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSu AFFORDING COVERAGE NAIL a INSURER A:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURER B. STATE INSURANCE FUND —62T06— Element Energy LLC INSURER c. DBA ELEMENT ENERGY SYSTEMS MURERD.GENERAL STAR MANAGEMENT CO. 7470 SOUND AVENUE INSURERE. MATTITUCK,NY 11952 INSURER F- COVERAGES CERTIFICATE NUMBER- REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLANS. ILTR TYPE OF INSURANCE PDLICY NUMBER POI EFF POLICY EXP LIMITS COMMERCIAL GENERAL lUiBILITY L1450036873 EACH OCCURRENCE 8 3,000,000 A X X 7I1412023 7/1dI2024 CLAIMS-MADE �OCCUR PREMISES Ea opwIrmoe $ 100.000 MED EXP{ we pesen) = 5000 X Contractual Lia IMA3892036 7119/2022 7/19/2024 PERSONAL&AOV NLIURY S 3000000 PL AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE 3 3.000,000 POLICY a EC F� LOC PRODUCTS-COMPIOPAGG s 3000000 OTHER: I 1 3 AUTOMOBILE LIABILITY COMBINEDSPIGLE LIMIT jEa t $ ANY AUTO SCHEDBODILY INJURY(Per person) t MED AUT ONLY AUTOS ULED ( BODILY INJURY Per aerident) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY p�aaJdBnt 3 8 UMBRELLA LIAB OCCUR EACH OCCURRENCE $ MESS LIAR HCLAW-5-MADE AGGREGATE $ DED I I RETENTION 3 $ WORKERS COMPENSATIONAND EMPLOYERT LIABILITY 124494445 PER FORT"- ANY RIETO IR PARTNE IEXECUTFVE YIN 7113fZ023 7/13I2024 AT ER B (Mandatory FFIEa CCLUDE . NIA E.L EACH ACCIDENT S 1 000 000 E.L.DISEASE-EA EMPLOYEE S If yes,describe Undef DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY 11UIT 3 NY State DBL DBL567527 110IJ2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks ScbedWe,may be atteebed 9 more 0paoe is rewrap) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certlificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Robe tS. Fed& 01938-2015 ACORD CORPORATION. All rights reserved. er-nDn'1c nn-lArnt► Tk-AP`l1Dn-- -.,...,a I--- —1.- r Ar•nnn /Pk\ NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 J nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) 0 � A A A A A A 823336604 _ ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 0 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTTTUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 W9075 07/13/2023 TO 07113QG24 7111/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YOM WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY.INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:IIWW W.NYSIF.COMICERTICERTVALASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION ANDIOR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT. THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED 13Y THE POLICY. NEW YORK STAT ZCE FUND id y OIRECTOR,INSURANCE FUND UNDERWRITING �ba APPROVED AS NOTED DATE:I1~I5-23 B.P.# 500a COMPLY WITH ALL CODES OF FE1 ",OD•00 BY: Ai� NEW YORK STATE &TOWN CODES A NOTIFY BUILDING DEPARTMENT AT S REQUIRED AND CONDITIONS OF 631-765-1802 8AM TO 4PM FOR THE SOMOLD TOWN ZBA FOLLOWING INSPECTIONS: $OLUOID TOWN WING BOARD FOUNDATION-TWO REQUIRED SOUTHOLD TOWN TRUSTS FOR POURED CONCRETE N.Y.S.DEC ROUGH-FRAMING&PLUMBING SOLBOLDNPC INSULATION SGID FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR Additional DESIGN OR CONSTRUCTION ERRORS Certification May Be Required. Qi5CO(Im4 mVt,+ 19-e JoCaj-Pd du+SiGe,) l alp�d a► d red i I ELECTRICAL INSPEC TION REQUIRED Zoho Sign Document ID:2A768FFA-C3MUUTPHK(3IS(;YIXUWMVUEU7KK_JUC:RTNHZ-EV2NH000 Town of Southold September 13th, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Lessard Residence, 4505 Main Rd, Laurel, NY 11948 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 3.0 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, OF NEW Gennaro Anthony Giustra. P.E. 0 A G�Gs0 Great Eastern Services, Inc. PO Box 240 24 Harvey Rd m z Riverhead, NY 11901 yNc� 5 O r03443 Mobile: 631.235.0189 ARoFESs�oNP`' Email: jerrygiustra@gmail.com ,'_oho Sign,Document ID:2A768FFA-GMQUTPHKGISCYIXUWMVUE07KK_JQCRTNHZ-EVZNHOQC SCOPE OF WORK EDEEL51MGNS DRAFTING by: T ENERGY LLC TO INSTALL A 19.44 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT LE55ARD RESIDENCE, M.NABCEP CERTIFIES LOCATED AT 4505 MAIN RD, LAUREL, NY 1 1948. 1 1 12- THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS E 51-RiP7ION DATE SYSTEM RATING 0 0 N•. . ,,w ORIGINAL 09-13-2023 1 9.44 kW DC STC Northville Laurel Robins Isla% EQUIPMENT SUMMARY 48 QCELL Q.PEAK DUO 13LK ML-G 10+ 405 WATT PV MODULES Ja export ye 48 ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS aaueoo9�e e� CONTRACTOR I IRONRIDGE XR 100 MOUNTING SYSTEM ELEMENT ENERGY, LLC. SHEET INDEX 7470 SOUND AVE PV-I COVER MATTITLICK, NY 1 1952 PV-2 SITE PLAN PROJECT LOCATION LICENSE # G74G I-HI PV-3 ROOF PV LAYOUT LICENSE # 52G89-ME PV-4 STRUCTURAL/DETAILS d SECTIONS PV-5 3-LINE ELECTRICAL DIAGRAM 4" PV-G LABELS ` GOVERNING CODES ��pF NEt.Vy t ,�P o A �� 0 2017 NATIONAL ELECTRICAL CODE. 2020 RESIDENTIAL CODE OF NEW YORK STATE. . e 2020 FIRE CODE OF NEW YORK STATE. L� A5CE 7-1 G AND NFPA-70. UNDERWRITERS LABORATORIE5(UQ 5TANDARD5 j BOA 1)3443 05HA 29 CFR 1910.2G9 " ' Si GENERAL NOTES -�C_t- 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS ATLLJ THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE �O U Q I- HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK AERIAL VIEW 2 z 0 G IN THE SAME. LLJ 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED C) _ APPROVALS, PERMITS, CERTIFICATES OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM W z z CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES O C� 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO C C ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. JURISDICTION. (0 Q Lo LLl I I. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE 0O () O CZ WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS W Lo Q THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. THI5 SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY s"FET NAME 5. ALL STRUCTURAL STEEL SHALL BE LATEST A.I.S.0 AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT FABRICATED AND INSTALLED AS PER LA LATE SPECIFICATIONS. CONSTRUCTION.IN BOARD FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE COVE G. ALL ELECTRICAL WORK SHALL DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND N ACCORDANCE WITH N.E.C. CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 7. CODES REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S I CO CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THI5 DRAWING SCALE CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON 8.THESE DRAWINGS O ERTY OF THE E OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. N .T.-. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THI5 PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF 0. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL v~cT FINAL PAYMENT EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS . PV— I RESULT OF HIS WORK. TAX MAP: 1000-125.00-01 .00-01 1 .000 ,Zoho Sign Document ID:2A768FFA-GMQUTPHKGISCYIXUWMVUE07KK_JQCRTNHZ-EVZNHOQC LEGEND TAX MAP: 1000- 125.00-0 I .00-0 I I .000 DesGN$DRAFTING BY: EXISTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL NEW PV SUB—PANELS �2 O REVIEW BYDS J.M.M.NZBCEP CERTIFIE A/C DISCONNECT a COMBINER 0o , INVERTERS GND ELECTRODE �0o REVISIONS DESCRIPTION DATE _ PV MODULE 1Oo D O ORIGINAL 09-13-2023 RACKING RAIL Vo 9'-211_ _ o ATTACHMENT POINT �(1&O° ,`S�o,- � -' ---RAFTERS v ROOF PITCH ANGLE 519SUNRUN METER = NET 0PLUMBNG VENT ®SKY LIGHT 1 2'-2�" CONTRACTOR ®CHIMNEY ®COMPOSITE SHINGLES ELEMENT ENERGY, LLG. GOOD ITION P01EN�DSHADING ISSUES = 7470 SOUND AVE LTRIM/REMOVE AS NECESSARY 0 � MATTITUCK, NY 1 1952 LICENSE # G74G I-HI LICENSE # 52G59-ME pF NEw 1 (5'- uj n w NEW PV AC D15CONNECT ip EY15TING MAIN ELECTRI AL RVICE PANEL 501- 1 11 103AA'3 SStor'P� I "FI SET9ACK RIDGE 18"FlRE SET9ACK @RIDGE PROJECT NAVE / 18"FIRE SETBACK RIDGE I O U Q ro w Z I- LLJ IS) C) - 18'- I o Q z 0) o o w/ _J n Q Ln W ' o Ln O Q 25'-77" SHEET NAME C. SITE PLAN NOTE 1.)THE ROOF 5ETBACK/PATHWAY SHALL NOT BE G"x 3G"GROUND ACCESS TYP. REQUIRED ON ROOF-SLOPES WHERE THE DRAWING5CALE OPP05ING OR ADJACENT ROOF SLOPE IS AN ACCESS ROOF IN ACCORDANCE WITH R324.G.1 1 /611 11_011 EXCEPTION OF 2020 NYS RESIDENTIAL CODE. CONSTRUCTION NOTES 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. �` /_ 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. v 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Zoho Sign Document ID:2A768FFA-GMQUTPHKGISCYTXUWMVUE07KK_JQCRTNHZ-EVZNHOQC CONSTRUCTION SUMMARY LEGEND DESIGN 8 DRAFTING BY: (48)QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES LLC (DIMENSIONS: 74'i X 4 1 .1"X 1 .3") OMAINEXISTING SE VICE TY PETER ELEMENT ENERGY CE AN REVIEW BY J.M.NABCEP CERTIFIE- (48) ENPHA5E IQ8PLU5-72-2-US MICRO INVERTERS �NEW PV SUB—PANELS osl I2-12e A/C DISCONNECT (108) ATTACHMENT POINTS @ G4"O.C. MAX. COMBINER (420.5) LF IRONRIDGE XR100 MOUNTING SYSTEM. INVERTERS GND ELECTRODE REVISIONS ROOF TYPE: ASPHALT SHINGLE (SINGLE LAYER) DE5CRIFTION DATE ; CONSTRUCTION NOTES PV MODULE ORIGINAL 09-13-2023 —RACKING RAIL 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE o ATTACHMENT POINT WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH A Y#I ---RAr7ERs ,` MINIMUM NEMA 3R RATING. V MODULES s—ROOF PITCH ANGLE 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE 340 PITCH SUNRUN METER FIELD VERIFICATION. 230 AZIMUTH ®VENT I '-4411 0PLUMBING VENT ®SKY LIGHT CONTRACTOR ®CHIMNEY COMPOSITE SHINGLES ELEMENT ENERGY, LLC. AIR 2 23 MODULES POTE OOD TIAL SHADING 7470 SOUND AVE POTENTIAL SHADNG ISSUES UTRIM/REMOVE AS NECESSAR MATTITUCK, NY 1 1952 34' PITCH 3130 AZIMUTH LICENSE # G74G I-HI LICENSE # 52G89-ME O of NEI.y Y �,<P �0 A 3'-2:T 0 _ � 'v �03443 �i $510�' e PROJECT�AV I p LL.I 2� 03 EX15TING MAIN ELECTRJCAL 5EPVICE PANE �- j- 1717z O m WLLJ (^ Z 18"FIRE SE K RIDGE �/ ) \ w r 42" 0 z N Q Lo W Rol- 77 o O � TRING/CONNECTION TYP. O LLJ Q J _1 V PANEL TYP. �`1FF`VAMF ICRO-INVERTER TYP. PV LAYOUT A RAY# 3 MODULES A- 340 PITCH p,y DRAwINs scA, 1330 AZIMUTH Oo ARRAY# 'NOTE 17 MODULES Oo 0 Q 1 .)THE ROOF 5ET5ACrJPATHWAY SHALL NOT BE 340 PITCH 6°x 30 GROUND ACCESS TYP. p REQUIRED ON ROOF-5LOPE5 WHERE THE 1 330 AZIMUTH �800 - 1 p OPPOSING OR ADJACENT ROOF SLOPE 15 AN Oo PO. ACCESS ROOF IN ACCORDANCE WITH R324.G.I PV-3 EXCEPTION OF 2020 NY5 RESIDENTIAL CODE. TAX MAP: 1 000- 1 25.00-0 1 .00-0 1 1 .000 Zoho Sign Document ID:2A768FFA-GMQUTPHKGISCYIXUWMVUE07KK_JQCRTNHZ-EVZNHOQC LOAD CALCULATION APPAY# ARP,AY#2 ARRAY#3 ARRAY#4 ITEM DESCRIPTION ARRAYS #I-4 DESIGN a DRAFTING BY: RB Rid e Bearrt/Boarci 1 .75"X 14" LVL ELEMENT ENERGY LLC R Rafter 2"X 1 2" D. FIR I G" O.0 REVIEW BY J.M.NABCEP CERTIFIE MODULE WEIGHT(Lb5) 48.4 48.4 48.4 48.4 (D) Deckin 5/8" PLYWOOD 051 1 1 2-1 29 #OF MODULE5 5 23 17 3 P Pitch 34° TOTAL MODULE WEIGHT(Lbs) 242.0 1 1 13.2 822.6 145.2 'J Cellm Joist 2"X 10" D. FIR 6"O.0 REV1510N5 (C Collar Tie5 2"X " D. FIR 45" O.C. DESCRIPTION DATE REV TOTAL LENGTH OF RAIL(Ft) G2.1 197.9 53.1 20.8 (TI) Horizontal Span of R 1 72" MAX. ORIGINAL 09-13-2023 RAIL WEIGHT PER FOOT(Lb5) 0.G8 0.G8 0.G8 O.GB TOTAL RAIL WEIGHT(Lb5) 42.2 1 34.G 3G.1 1 4.I (RB) #OF 5TPANDOFF5 20 4G 34 8 ({� WEIGHT PER 5TPANDOFF(Lb5) 2 2 2 2 (D) TOTAL 5TANDOFF'WEIGHT(1-1,5) 40 92 C8 G TOTAL ARRAY WEIGHT(Lb5) 324.2 1 339.8 92C.9 175,3 POINT LOAD(Lb5) I G.2 29.1 27.3 2 1.9 CONTRACTOR TOTAL APPAY AREA(56[Ft) 107 1 492.4 3(;4.0 G4.2 ELEMENT ENERGY, LLC. ARRAY DEAD LOAD(Lbs/Sq 7470 SOUND AVE Ft) 3.0 2.7 2.5 2.7 MATTITUCK, NY 1 1952 LICENSE # G74G I -HI WIND DF51GN 5UBJECT TO DAMAGE FROM GROUND SEISMIC WINTER ICE BARRIER FLOOD AIR MEAN (P) LICENSE # 52G89-ME SNOW DE51GN Frost Df51GN UNDERLAYMENT HFLO D59 FREEZING ANNUAL (C) LOAD' 5peed° Topographic 5pecial Windborne CATEGORY' Weathering' line Termite` TEMP` REQUIRED INDEXi TEMP/ (mph) effects wind region debris zone'" depth" FEMA oF NEw 20 140 NO NO NO B SEVERE 3 FT MOD 15°F YES ZONE X 599 5 I°F �Q �O A �0,Q� MANUAL J DE51GN CRITERIA° * 1 Indoor LLJ W Winter Summer dell n Heatm tern erature (H ZN 2 Elevation Latitude heating cooking Altitude correction factor temrera Design temperature cooling differencetur (J) 43g4 �O 10 3 108FT 41°N I51F 8G°F 1.00 70°F 75°F 551E ARO�sstoNP� Wind Wind Coincident Winter PROJECT tiAV` Cooling temperature difference velocity velocity Daily range Summer humidity _ heating cooking wet bulb humidity I O W Q 00 ROOF FRAMING DETAIL I I 1 5°F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GR @50%PH u_ z For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. LLJ O a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth } - strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as z determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. Q LU b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction JO � Q z shall fill in the frost line depth column with the minimum depth of footing below finish grade. Q Q J C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. MODULE MOUNTING CLAMP d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined LE w R/ W^/ on a site-specific basis in accordance with Section R301.2.1.4. SOLAR MODU O Q L.L e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York 5TAJNLE55 5Tff Sib' 0- (S) O State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also BOLT AND NJ' O (s) Ln see Figure R301.2(1).] W/ � Q f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New NRIDGE ALUMINUM RAIL ` York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the ALUMINUM"L•SRACK 7 Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: EE-"AVE i.The accompanying Flood Insurance Rate Map(FIRM), !uMINUM F ADyING ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. STRUCTU R n L The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. IV h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ASPHALT SHINGLE ROOF effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." 5/1 G"x G'5TAJNLE55 i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) STEEL LAG BOLT WTH value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 327)." 2 112`MIN THREAD j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method PENETRATION 5EALED DRAWING 5CALE WITH GEOCEL 4500 (Base 32°F)." (EQUIVALENT OR BETTER)k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the AS NOTED jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the SHEET NUMBER jurisdiction. Q\ /_4 o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at �[ I �/ elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. TAX MAP: I OOO-1 25.00-01 .00-0 1 1 .000 MOUNTING DETAIL I 1 (`) See Figure R301.2(4)B Zoho Sign Document ID:2A768FFA-GMQUTPHKGISCYIXUWMVUE07KK-JQCRTNHZ-EVZNHOQC DESIGN s DRAFTING PROPOSED SOLAR ARRAY ON MAIN HOUSE 1 9.44 kW ELEMENT ENNERGYEIRGYBy LLC (48)QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES (3)STRINGS OF(1 3)MICRO-INVERTERS 4(1)STRING OF(9)MICRO-INVERTERS 05 REVIEW BY J.M.NABCEP CERTIFi '(4)STRINGS TOTAL OLAR MODULE TYPICAL TO UTILITY GRID REVISIONS STRINGS # 1 -3 DE5CRIPTION DATE REv �- ---------------- ENPHASE -2023 1 N ORIGINAL 09-13 - - - - - - - - - - - - - - - - BRANCh BI-DIRECTIONAL --' TERMINATOR UTILITY METER _-__-- TYPICAL I , 1 N I POINT OF INTERCONNECTION I PER NEC 240.21(13)(1)4 690.64(A) GT11 OF TAP CODUCT STRING #3 ShALL NO7 EXC EDN 0 FTC I _ I CONTRACTOR --- DISCONNECT 240 V.200A ELEMENT ENERGY, LLC. � -----� ------ ------ -----� ------ ------ ------ --- ENPHA5E BRANCH MICRO-INVERTER 7470 SOUND AVE I CIRCUIT CABLE TYPICA- ENPhASE I06PW5-72-2-US MATTITUCK, NY 1 195 I 240 VAC. A LICENSE # G74G I-HI 97%CEC-WEIGHTED EFF. ACD15CONNECT NEMAG.ULL15TED t LICENSE # 52G(59-ME TYPICAL 50 D D223NRB 1 240 VAC. 100 A NEMA 3R.UL U5TED _1 (2)80 A FUSE5 t t OF NEw °A °A 5 a C,jP2 P¢0 4 GQP� I MAIN SERVICE PANEL y 1 - - °n.3-W r -- ----- --------------------------------------------------� zoonnC A3�O 10 4 AC COMBINER BOX 4 i N AR 34 240 VAC 80 A 1 1 G QCrSS��`_ NEMA 3R.11 uSTED _ C (4)20 A DOUBLE POLE DREMER5 1 I I I4 4 � I 1 j I I D(15TING GROUNDING PROJE'T%AV- ELECTRODE5Y5TEM 1 i ---------- , LJ o LU Q � I I w z O m 1 , o _ WIRE CONDUIT SCHEDULE _ CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(To Q W z }- D # ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE 51ZE TEMP DEBATE DISTANCE _j a Q z 310.15(B)(3) 310.15(B)(2a)/(3c) N Q C INVERTERS COMBINER PANEL AWG#10 1 8 0.7 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I" 55°C 0.84 90 FT 1.79% G OR EMT � Q � W COMBINER PANEL AC D15CONNECT AWG#4 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 454C 0.95 25 FT O.G2% 0 < Ln 3 AC DISCONNECT MAIN PANEL AWG#4 I 3 I THWN-2 AWG#8 THWN-2 CU PVC I" 45°C 0.95 10 FT 0.G2% LLJ Q ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR 75 APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. [NEC G90.8(B)(I)I: (Isc)'(#of stnngs)'(I.5G) = 19.GG A 3-LINE D I A. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY Modules per String 13 MAX. TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE,HIP,OR VALLEY. AWG#I O, 19.GG A, Temp Derate = 23.52A 23.52 A>19.66 A,therefore DC wire size is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL #2 Inverter Output Wire Ampacity Calculation Number of Inverters 8 COMPLYDRAWINGS IN NEC 110.2G. Inverter Max Am era a output (1.25)= 72.G A 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL P 9 P Record low temp -I O°C FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE5SORIE5 TO FULFILL AWG#4,ampacity'(femp Derate)'(Conduit Fill Derate) = 90.25 A Voc Temp Coefficient -0.24%/QC DRAWING SCALE APPLICABLE CODES AND STANDARDS. 90.25 A> 72.G A,therefore AC wire size is valid. G.)WHERE SIZES OF JUNCTION BOXE5, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation DC SYSTEM SPECIFICATIONS C� THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. Inverter Max Amperage output'(1.25)= 72.G A O eratin Current 10.8 A N .T.✓. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#4,ampac ty'(femp Derate)'(Conduit Fill Derate)= 90.25 A Operating Volta6le 37.4 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 90.25 A> 72.G A,therefore AC wire size is valid. Max. System Voltage 49.G V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG AC SYSTEM SPECIFICATIONS OR IL5CO GBL-4DBT LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) Max AC Output Current 72.G A �` �- OR O eratin AC Volta 240 V V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000- 1 25.00-0 1 .00-0 1 1 .000 :Zoho Singe Document ID:2A768FFA-GMQUTPHKGISCYtXUWMVUE07KK_JQCRTNHZ-EVZNHOQC DE51GN a DRAFTING BY: SERVICE METER I OO INSTALLATION NOTE ELEMENT ENERGYLLC y REVIEW BY J.M.NABCEP CERTIFIE SOLAR PV SYSTEM ! PHOTOVOLTAIC • r • ( I ) ALL LABEL SHALL BE INSTALLED IN 051 1 1 2-1 20 EQUIPPED WITH 9 SOLAR BREAKER ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® •• • • REQUIREMENTS. REvisio• DESCR DAIPTION DATE REv OPERATING CURRENT A • (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 09-13-2023 SOLARMAX SYSTEM VOLTAGE AC LOAD CENTER - OUTSIDE DO NOT RELOCATE THIS: .• • REQUIRE FIELD VERIFICATION. ovERCLIRRENTNMCE (3) LABELS, WAKNING(S) AND MARKING O3 nJIiNROOSHUTDOWSWITCHTD O SHALL BE IN ACCORDANCE WITH NEC TIE•DFF'POSITION TO SIft1T DOIA I 10.2 1 (B). i PV SYSTEM AID REDUCE ' SHOCK HAZARDIN THE ARRAY AC DISCONNECT PO .TOTNSCSEERICIEEIISALSOSUPPLIED (4) THE MATERIAL USED FOR MARKING _ MC MEECTSLOCATEDASBHS MUST BE WEATHER RESISTANT, IN O DISCONNECTS LOCATED AS BNOWN SOLAR AC LOAD CENTER - INSIDE 2 e COMPLIANCE WITH NEC 1 10.2 1 (B)(3). CONTRACTOR (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLC. 4 7 8 I I 7DUA ARNING w""y 7470 SOUND AVE O O O O '� SHALL BE LABELED INSTALLED I N MATTITUCK, NY 1 195SOURCTHIS E S TDI LRRWINGOMENT FED BY FA�u ER SUPPLY + —�i LICENSE # G74G 1-111 oVERaIrrDEwrEs.ExcLuo�c, s:LmLTTYGRID COMPLIANCE WITH NEC 690.31 . LICENSE # 52G89-MEMART SUPPLY OVERCURRENT PV SOLAR DEVICE,SHALL MDT EXCEED ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING IWFI1CiTYOFRXW OF NEI,I,Y 30 _ 7 VA ° A 1 WARNING I THIS SERVICE METER E: II PHOTOVOLTAIC SYSTEM IS ALSO SERVED BY A U A r v TEf�ItiALS ONT ELECTRIC SHOCK NTHE LINE AND I CAR PANEL =I PHTAIC SYSTEM ; OTOVOL LOAD SIDES MAY BE ENERGIZED ` DO NOT ADD LOADS I �� 103443 CONDUIT - OUTSIDE BUILDING -IN THE OPEN POSITION ARO SStoNP� OPROJECT NAV, --� • - 0 U Q DUAL POWER SUPPLY SOURCES:UTILITY GRID AND � z O 1J I PV SOLAR ELECTRIC SYSTEM I j Q — MAIN SERVICE PANEL - OUTSIDE O ACAUTION SOLAR CIRCUIT Q W Z Cz 0 CZ Z O2 O �5 -CAUTION _ p O SOLAR aECTRIC SYSTEM CbNECw p• • • • n Q Ln LLl 6 0 (s) O CZ AC DISCONNECT 0 (n Lo MAIN SERVICE PANEL - INSIDEOPERATING CURRENT J OPERATING VOLTAGE Voi Ts POWER SOURCE i OUTPUT CONNECTION ® O DO NOT RELOCATE THIS OVERCURRENT DEVICE LABELS AC DISCONNECT/BREAKER DRAWING 5CACL: 000 � ® N .T.5 . PV-6 TAX MAP: 1000- 1 25.00-01 .00-01 1 .000 Aho Sign Document ID:2A768FFA-GMQUTPHKGISCYIXUWMVUE07KK_JQCRTNHZ-EVZNHOQC NG by: SCOPE OF WORK - DELEMESIGNNT RP.FTIYLLG ' ELEMENT ENERGY LLC REVIEW BY J.M.NABCEP CERTIFIE TO INSTALL A 19.44 KW 50LAP PHOTOVOLTAIC(PV)SYSTEM AT LE55APD RESIDENCE, (2 � t �••;�.' ,/,•'7U` •I `c; LOCATED AT 4505 MAIN RD, fAUREL, NY 11948. _Futc ague" L _ lr� a.. os l I 1 2-1 29 THE POWER GENERATED BY THE PV5Y5TEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS DESCRIPTION DATE REV �$ f''' +r• - New SuffolIrak ORIGINAL 09-13-2023 5Y5TEM RATING B� Q�= '"ak,•.` .- ~ 19.44 kW DC 5TC Northville - •'(t Laurel R66insls/ana EQUIPMENT SUMMARY •• •f_ No Sea _ Jamesport'• 1 Beach 48 QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES 48 ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS Aquebog e.�- •ys "` sou% �� CONTRACTOR I IRONRIDGE XR100 MOUNTING SYSTEM J'y PUR 1` ELEMENT ENERGY, LLC. f•: S I1 EET INDEX 7470 SOUND AVE MATTITUCK, NY 1 1952 PV-I COVER PV-2 SITE PLAN PROJECT LOCATION LICENSE # G74 1-111 PV-3 ROOF PV LAYOUT , LICENSE # 52G89-ME PV-4 STRUCTURAL/DETAILS SECTIONS PV-5 3-LINE ELECTRICAL DIAGRAM " PV-G LABEI-5 of; NEW, GOVERNING CODES s P 2�O A C9 O'�Gd,O�ir 2017 NATIONAL ELECTRICAL CODE. e 2020 RESIDENTIAL CODE OF NEW YORK STATE. 0 Lu 2020 FIRE CODE OF NEW YORK STATE. A5CE 7-1 G AND NFPA-70. O �10344 J �O UNDERWRITERS LABORATORIES(UL)STANDARDS 05HA 29 CFR 1 910.2G9 f ROFESStONP� i GENERAL NOTES ` PROJECT NAME LL-j Cl co 1 . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT ' 0 O THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE U HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK �� LLJ Z O AGREE THE SAME. AERIAL VIEW n Q - 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'5 COMPENSATION, IL/ Q Z AGENCIES HAVING JURISDICTION THEREOF—, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO p C J ALL RULES AND REGULATIONS OF THE RESPONSIBLE W COMMENCING WITH WORK. JURISDICTION. 1 1 . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR 0 L� 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB 51TE DURING THE WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS W O Q THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND —I ENGINEER. SHOULD HE FAIL TO FOLLOW TH15 PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT CONTINUE WITH THE WORK, HE SHALL A55UME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SHEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 CONSTRUCTION. COVER SPECIFICATIONS. 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE _ G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. t- CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NY5 CODES $ REGULATIONS CONDITIONS PRIORTO ORDERING MATERIALS AND 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. DRAWING SCALE CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON �j 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. N •T• SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK,THE SITE TO BE CLEARED PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THIS PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. p EXISTING WORK ADJACENT TO HI5 WORK, OR DAMAGED AS I V " RESULT OF HIS WORK. TAX MAP: 1000- 125.00-0 I .00-0 I 1 .000 Zoho Sign Document ID:2A768FFA-GMQUTPHKGISCY1 XUWMVUE07KK-JQCRTNHZ-EVZNHOQC �© DESIGN$DRAFTING BY: �`�- I r. �� , PROPOSED SOLAR ARRAY ON MAIN HOUSE 19.44 kW \ -•� ELEMENT ENERGY LLC (48)QCELL Q.PEAK DUO BLK ML-G 1 O+405 WATT PV MODULES (3)STRINGS OF(1 3)MICRO-INVERTERS#(1)STRING OF(9)MICRO-INVERTERS t ` �. _;7 .,_'� 1 ( REVIEW BY J.M.NA CERTIFIE '(4)STRINGS TOTAL OLAR MODULE TYPICAL l I 7 051112-129 29 TO UTILITY GRID DEC 2 0 2023 - REVISIONS STRINGS #1 -3 DE5CRIPTION I DATE REV ---------------- -- ENPHA51f - N ORIGINAL 1 09 13 20231 - _ - - - - - - - - -< y.- - - - - - _ _ _ _ _ B TERMINATOR n- POINT UT- ------------------- UTILITY METAFTYPICALPHASE.240�/>4t: . i.OF INTERCONNECTION PER NEC 240.21(5)(1)4 G90.G4(A) �1 LENGTH OF TAP CONDUCTORS STRING #`Y ... SHALL NOT EXCEED I Off ti I - CONTRACTOR - ------- ----- ---- ------ ------ ------ ------ MAIN SERVICE DISCONNECT ELEMENT ENERGY, LLC. � _----- zao V.zoo A ENPHASE BRANCH MICRO-INVACVERTER 7470 SOUND AVE CIRCUIT CABLE TYPICAL ENPHASE IQBPLUS-72-2-US MATTITUCK, NY 1195 07%CEC-WEIGHTED EFF. AC DISCONNECT 1 LICENSE# 52G89-ME I NEMA G.UL LISTED TYPICAL 50 D D223NRB 240 VAC. 100 A NEMA 3R.UL USTED 1 1 N L LI N L 1-1OF NEW (2)80 A FUSES �P RO A Ci O OA OA 50A C9 I MAIN SERVICE PANEL TQiI N N I-PH.3-W ZN� - - -- 240 VAC 0344 7 3 N )rjaI r -- � ----- � ----------------------------------------------------, zooA O AC COMBINER BOX 4 I I 240 VAC.50 A I I "rO'CSS1�`_P NEMA 3R.UL U5TED -1 2.A DOUBLE POLE BREAKERS i I G -1 I I I I I EXISTING GROUNDING PROJECT NAME I I I I ELECTRODE SYSTEM j -----------U I 0 W 00 w w WIRE CONDUIT SCHEDULE - CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% W z I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE DISTANCE a/ Q z 310.15(B)(3) 310.15(B)(2a)/(3c) Q Q J INVERTER5 COMBINER PANEL AWG#12 1 8 0.7 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I,, 559C 0.54 90 FT 1.79% OR EMT to W 2 COMBINER PANEL AC DISCONNECT AWG#4 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45QC 0.95 25 FT O.G2% O O 3 AC DISCONNECT MAIN PANEL AWG#4 3 I THWN-2 AWG#8 1 THWN-2 CU PVC I" 459C 0.05 10 FT O.G2% Q W L Q ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. [NEC G90.8(B)(I)]:(I5c)'(#of 5trin s)'(I.5G) = 1 5.73 A 3-LINE D I A. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 9 Modules per String 13 MAX. AWG#12,ampacity'Temp Derate= 17.G4 A TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 17.G4 A> 15.73 A,therefore DC wire size is Valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 48 COMPLY WITH NEC I 1 0.2G. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL Inverter Max Amperage output'(1.25) = 72.G A Record low temp -I OQC FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE55CRIE5 TO FULFILL AWG#4,ampacity'(Temp Derate)'(Condult Fill Derate)= 90.25 A Voc Temp Coefficient -0.24%/QC DRAWING SCALE APPLICABLE CODES AND STANDARDS. 90.25 A> 72.G A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. Inverter Max Amperage output' (1.25) = 72.G A Operatinqj Current 10.8 A N .T.5. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#4,ampacity'(femp Derate)'(Condult Fill Derate) = 90.25 A Olperatinqj Volta e 37.4 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 90.25 A> 72.G A,therefore AC wire size is valid. Max. System Voltage 49.G V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEK LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR IL5CO GBL-4DBT LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5itive/negative) Max AC Output Current 72.G A PV-5 OR O eratin ACVolta e 240 V 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000-1 25.00-0 1 .00-0 1 1 .000 Zoho Sign Document ID:2A768FFA-GMQUTPHKGISCYIXUWMVUE07KK_JQCRTNHZ-EVZNHOQC DESIGN 4 DRAFTING BY: ELEMENT ENERGY LLC PROPOSED 50LAP ARRAY ON MAIN HOUSE 19.44 kW (48)QCELL Q.PEAK DUO ELK ML-G 10+ 405 WATT PV MODULES REVIEW BY J.M.NABCEP CERTIF)E (3)STRINGS OF(1 3)MICRO-INVERTERS S(1)STRING OF(9)MICRO-INVERTERS o51 I 1 2-129 OLAR MOD '(4)STRINGS TOTAL MODULE TYPICAL TO UTILITY GRID PEV1510N5 DE5CRIPTION DATE REV STRINGS #1 -3 _ _ _ _ _ _ _ _ _ - - _ _ , N ORIGIIJAL 09-13-2023 ENPHASE �- ---------------- -- BRANCH BI-DIRECTIONAL TERMINATOR UTILITY METER TYPICAL I-PHASE.240 V I t I I I POINT OF INTERCONNECTION ) PER NEC 240.21(d);U i 590.94(A) ZNGTH OF TAP CONDUCTORS SnALL NOT EXCEED 10 FT STRING #3 I - - -- -- - - - - CONTRACTOR I MAIN 5ERVICE 015CO14NFCT 240V.200A ELEMENT ENERGY, LLC. I I - 7470 SOUND AV ENPHASE BRANCH MICRO-INVERTER MATTITUCK, NY 1 1 95 CIRCUIT CABLE TYPICAL 240 VAC.IOI 21 A 72 2 USNPI1 LICENSE # G74G I-HI I 97%CEC-WEIGHTED EFF. LICENSE # 52G69-ME I I AG DISCONNECT NEMA G.UL LISTED TYPICAL I SQ 7 7223NR3 240 VAC. 100 A NEM 3R.UL 115TE7 t OF NEII/ O BO A FUSES CO OA OA 50A ,- MAIN SERVICE PAIJEL m �� N N I-PH.3-W 1 - _ - �• 240 VAC �O 703443 ~ r- -- ----- G ---------------------------------------------------� 200A 4 AC COMBINER BOX 4 I I - AR0 SS1ONP� 240 VAC.B Ci OA I -1 NEMA 3R.A J5TED I I G (>I 20 A DOUR E FOLE 5REA:ERS I I I EXISTING GROUNDING PROJECT NAME I I I I ELECTRODE SYSTEM ----------- O W C) CO I - z Q I I - - w I W LL L-------------- C� - ---------- -------------� > - ------------- WIRE CONDUIT SCHEDULE cn CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop Rb Q z I.D. # ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION 51ZE QUANTITY INSULATION (CU/AL) TYPE 51ZE TEMP DEBATE DISTANCE 0O Q Z 310.15(TE 310.15(I5)Qa)/(3c) Ln Z 1 INVERTER5 COMBINER PANEL AWG#1 0 1 8 0.7 U5E-2/PV Wire AWG#8 I BARE CU FREE AIR I" 55°C 0.84 90 FT .79% p CZ J OR EMT � Q � W 2 COMBINER PANEL AC DISCONNECT AWG#4 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45gC 0.95 25 FT O.G2% OLn O 3 AC DISCONNECT MAIN PANEL AWG#4 I 3 I THWN-2 AWG#8 I THWN-2 CU PVC I" 45°C 0.95 10 FT 0.G2% OQ W SHEET NAME ELECTRICAL NOTES CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED POP GOO V AND 90°C WET ENVIRONMENT. [NEC G90.8(B)(I)I: (Isc)'(#of 5tnng5)'(I.5G) = 1 9.GG A Modules per String 13 MAX. 3-LINE D I A. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY AWG#10. ampacity'Temp Derate= 23.52A TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. 23.52 A>1 9.GG A. therefore DC wire size is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL #2 Inverter Output Wire Ampacity Calculation Number of Inverters 8 COMPLY WITH NEC 1 10.2G. Inverter Max Amperage output' (1.25) = 72.G A Record low temp -109C 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL AWG#4,ampacity'(Temp Derate)'(Cond Voc Temp Coefficient -0.24%/C uit Fill Derate) = 90.25 A sz DRAWING SCALE FURNISH ALL NECESSARY OUTLETS, SUPPORTS-FITTINGS AND ACE55ORIE5 TO FULFILL 90.25 A> 72.G A.therefore AC wire size Is valid. DC SYSTEM SPECIFICATIONS APPLICABLE CODES AND STANDARDS. G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS'ARE NOT SPECIFIED. #3 Inverter Output Wire Ampacity Calculation O eratin Current 10.8 A N .T.S . THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. nverter Max Amperage output' (I.25) = 72.G A AWG#4,ampacity'(Te 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY V15IBIE. mp Derate)'(Gonduit F111 Derate) = 90.25 A O eratin Volta e 37.4 V 8.)MODULE GROUNDING CUPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 90.25 A> 72.G A, therefore AC wire size is valid. Max. System Voltage 49.G V SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEED LUG f /J AC SYSTEM SPECIFICATION5 SHEET NUMBER OR IL5CO GEL-4DET LAY-IN LUG. I L Max AC Output Current 72.G A \/ 5 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/neg Oeratin AG Voltae 240 Vative) -`' OR .000 10.)THE DC SIDE OF THE PV 5Y5TEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000- 1 25.00-0 1 .00-0 1 1