Loading...
HomeMy WebLinkAbout46321-Z �o�Og�FFa�r 1Kc y Town of Southold 1/14/2024 P.O.Box 1179 � ' 53095 Main Rd �y?j01 �ao�r Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44863 Date: 1/14/2024 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 980 Greton Ct.,Mattituck SCTM#: 473889 Sec/Block/Lot: 107.-2-3.5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/7/2021 pursuant to which Building Permit No. 46321 dated 5/27/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: additions and alterations, including garage and outdoor shower,to existing single family dwelling as applied for. The certificate is issued to Gonzalez II,Mario&Jennifer of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R-21-766 7/8/2021 ELECTRICAL CERTIFICATE NO. 46321 6/13/2022 PLUMBERS CERTIFICATION DATED 1/26/2022 a Piecuch ut riz ignature r gOFFQ(�c`• TOWN OF SOUTHOLD ��o gay BUILDING DEPARTMENT ca TOWN CLERK'S OFFICE o . SOUTHOLD, NY y�ol � Sao BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46321 Date: 5/27/2021 Permission is hereby granted to: Gonzalez II, Mario 25 Clermont Ave Brooklyn, NY 11205 To: Construct additions-and alterations to existing single family dwelling as applied for, with SCHD. At premises located at: 980 Greton Ct., Mattituck SCTM #473889 Sec/Block/Lot# 107.-2-3.5 Pursuant to application dated 5/7/2021 and approved by the Building Inspector. To expire on 11/26/2022. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $889.60 CO-ADDITION TO DWELLING $50.00 Total: $939.60 Building Inspector I I o��OF SO(/r�,ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 iQ sean.devlin( -town.southold.ny.us Southold,NY 11971-0959 �yc4UNT`I,� BUILDING DEPARTMENT TOWN OF.SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mario Gonzalez II Address: 980 Greton Ct city,Mattituck st: NY zip: 11952 Building Permit#: 46321 Section: 107 Block: 2 Lot: 3.5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: G&S Electric License No: 578ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1 st Floor X Pool New X Renovation 2nd Floor X Hot Tub Addition X Survey Attic X Garage X INVENTORY Service 1 ph Heat Duplec Recpt 39 Ceiling Fixtures 24 Bath Exhaust Fan 3 Service 3 ph Hot Water GFCI Recpt 6 Wall Fixtures 10 Smoke Detectors 4 Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures 3 CO2 Detectors Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO 3 Transformer UC Lights Dryer Recpt 30A Emergency Fixtures Time Clocks Disconnect Switches 4$ 4'LED Exit Fixtures 11 Pump Other Equipment: W/D, Mini Split 1 Blower Head Notes: Two Story Addition w/Attached Garage Inspector Signature: Date: June 13, 2022 S.Devlin-Cert Electrical Compliance Form zl� SO Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax (631)765-9502 P.O.Box 1179 00) Southold,NY 11971-0959 �� roper.richert(a town.southold.ny.us �� OOU� � BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Earl Bedrick Address: 980 Greton Ct City: Mattituck St: New York Zip: 11952 Building Permit* 45241 Section: 107 Block: 2 Lot: 3.5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Pumillo Electric License No: 2300-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 22 Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors 2 Main Panel A/C Condenser Single Recpt Recessed Fixtures 7 CO Detectors 2 Sub Panel 100a A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 10 Twist Lock Exit Fixtures 11 TVSS Other Equipment--WS-S171 "ELECTRICAL SURVEY" "NO VISUAL DEFECTS" N�tes: 2-combination smoke/co detectors,4 ft track lighting -------------------- Inspector Signature: Date: September 24 2`II20 81-Cert Electrical Compliance Form.xls it sQUTyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road CAR Fax-(631)765-9502 P.O.Box 1179 + �� Southold.NY 11971-0959 +N/ttl�s BUILDING DEPARTAdENT TOWN OF LITHO FAQ 1 2022 TOWN OF SOUTFIpLD CERTIFICAT-I-Q-ITT Date: kw,' 'qQ Building Permit No. Owner. Ct'.0ft-W (Please print) Plumber:Ar6J, Pjet`,ur_k (Please-print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. .Signature) Swom to before me this oZ. day o 24 _ SUSAN A.R ZZO / Notary Public,State of New York // No.-OtR16183459 Notary Public, Ale �`G County Commission Qualified n Sres March County tv�>[ �\%fSO�l Hp # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 _ INSPECTION [ /FOUNDATION 1ST [ ] ROUGH PLBG. [ OUNDATION 2ND [ ] INSULATION/CAULKIN-G [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] -FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: s DATE I Y INSPECTOR Of SOUj yo Ll &521/ q&,o 6 (f � f * TOWN OF SOUTHOLDBUILDING DEPT. •/VI cvurm, ' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ]- FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE l T INSPECTOR SOpTyo TOWN OF.SOUTHOLD BUILDING: DEPT. 765-1802 INSPECTION . [ ] FOUNDATION 1 ST [ ] OUCH PLBG. [ ] 'FOUNDATION 2ND [ INSULATION/CAULKINQ, [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ _] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: t 0 aCad- DATE �Iq INSPECTOR OF SOUlyolo # # TOWN OF SOUTHOLD BUILDING DEPT. cou 765-1802 1 NSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND : [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O jRE RKS: Ub ©lOK OKW -F*-�Ljg ) F DATE , - ZZ -�=- - INSPECTOR OFSOUIHpIo - # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION _ [ ] ELECTRICAL (ROUGH) k,4 ELECTRICAL (FINAL) [ ] CODE VIOLATION [( ] PRE C/O [ ] RENTAL REMARKS: 0' DATE I INSPECTOR '' �o�aOF SOUTyO� �p3y f TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 6-yl Zgb i^ mod w,#,-[iL - DATE �� 12' INSPECTOR OF SOUTyO� # # TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATIOWCAULKING [ ] -FRAMING/STRAPPING [ FINAL R� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMAR S: DATE K INSPECTOR "IlyIL i K r . T Alp for r r / �2n,12.F 1 SCH 40 �� �f'` i�°' '�'.r'y r •�` �! •d �'yi/r � r � ry,4,, � cam. � 1 I� W a; y l P oaa - s)r`•vim ..� _ 1 . P { 1 t TOTO _ I 1 ma'It. � I r ' IT Ll /77 t 1 r • r � G y I x • � r�jL a • Y � L- THE TURETT COLLABORATIVE `'� �� I • I 082321 RE:980 Greton Court, Mattituck, NY Att:John Jarsky, Senior Building Inspector Southold Building Department 64375 Main Rd PO Box 11.79 Southold, NY 11971 Dear Mr. Jarsky, I have conducted a plumbing inspection on August 20th, 2021 at 980 Greton Court, Mattituck and it met the plumbing code requirements. Thank you. Sincerely,Wayne Turett UV ED A oF��+�° D AUG 2 5 2021 BUTLDrN'G DFPT. TOWN OF SOUTHOLD 277 BROADWAY NY, NY 10007 STUDIO 1300 T. 212.965.1244 W:TURETTARCH.COM IG:®TURETTCOLLABORATIVE Nunemaker, Amanda From: Wayne Turett <wayne@turettarch.com> Sent: Monday,August 23, 2021 10:12 AM To: Nunemaker,Amanda Subject: 980 Greton Court Attachments: IMG_4182 jpg; IMG_4177 jpg; IMG_4158 jpg; IMG_4159 jpg; IMG_4181 jpg; IMG_ 4153jpg Hi Amanda, I am the architect for the house addition at 980 Greton Court, Mattituck. Last Friday I was on-site and did a plumbing inspection.The contractor pressurized the piping to 70 lbs. and it held for an hour. Is there a form for me to fill out for plumbing inspections? Is this email sufficient? I've attached a couple of photos of the piping. Please let me know if I need to do something different. Thank you, Wayne WAYNE TURETT,Principal THE TURETT COLLABORATIVE ARCHITECTURE . INTERIOR DESIGN 277 Broadway Studio 1300 New York,NY 10007 T:212.966.12"ext 413 T:917.470.9759 direct number www.turettarch.com 0-)turett arch CcD-tcinteriors facebook This E-mail,including any attachments,is confidential and for the intended recipient only. Unauthorized use or distribution is prohibited and may be unlawful. ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. , FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) W y ------------------------------------ C FOUNDATION(2ND) 000, H ROUGH FRAMING& PLUMBING r INSULATION PER N.Y. y �� STATE ENERGY CODE / ,,sue (&e4 FINAL �V 4&A SOl LOW Ylot P4%-7 ADDIT NAL COMMEN 150 . on v_le-c.4qGl-lAl 'Oh r a a r A2K&L �rn !13=tea eLut- 'ri �c�-_e:s i r\cl►AdLL u- o � d (o�SufFot��oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT tJ; yid �C Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 W-��a Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtomm Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT No. 3�1 Building Inspector: MAY 7 2021 Applications and forms must be filled out in their entirety. Incomplete _ .:applications will not be accepted. Where the Applicant is not the owner,an ,1'? Owners Authorization form(Page 2)shall be completed. TC-1 Date:March 29 2021 OWNER(S)OF-PROPERTY: Name:Jennifer and Mario Gonzalez SCTM# 1000- Project Address:980 Greton Ct. Mattituck NY 11952 Phone#:646-509-3471 Email:jennifermsims@gmail.com Mailing Address:980 Greton Ct. Mattituck NY 11952 CONTACT PERSON: Name:Jennifer Gonzalez Mailing Address:980 Greton Ct. Mattituck NY 11952 Phone#:646-509-3471 Email:jennifermsims@gmaii.com DESIGN PROFESSIONAL INFORMATION: Name:Wayne Turett'PC dba The Turett Collaborative Mailing Address:277 Broadway Studio 1300 New York, NY 10007 Phone#:212.965.1244 Email:wayne@turettarch.com CONTRACTOR INFORMATION: Name:Rob Gabrielsen Mailing Address:Gabrielsen Builders, LLC POB 317 Jamesport, NY 11947 Phone#:516-322-1537 Email:gabrielsenbuild@optonline.net DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure DAddition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $200,000 Will the lot be re-graded? ❑Yes ©No Will excess fill be removed from premises? Dyes ®No 1 PROPERTY INFORMATION Existing use of property: cl COB Intended use of property: 5/A/&1.ei Zone or use district in which premises is situated: Are there any covenants pd restrictions lwith respect to this property? ❑Yes Lido IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as'provided'by Chapter 236 of the Town'Code. APPLICATION IS HEREBY MADE to the Building Department-for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the.Town of Southold,Suffolk,County„ York and other applicable Laws,Ordinances or Regulations,for the construction of buildings; additions,alterations or for removal or demolition as herein described.The applicant agrees to'comply with all applicable laws,ordinances,building'code,, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements,made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. 1/u Pr ry a v 7z Application Submitted By(print name): 1101 1 126444dL W-Authorized Agent Amwner Signature of Applicant: / '"-- --- Date: March 29 2021 STATE OF NEW YORK) SS: COUNTY OF WaN►,e wfe-klir- being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the af'.n} (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best oWVigfr�w V%and belief;and that the work will be performed in the manner set forth in the application ftrt INlYA-13-STATE OF NEW YORK No.01 IA6409771 Sworn before me this Qualified in Suffolk County y Commission Expires 10-05-2024An Zday of [Y , 20<31 "� Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Jennifer Gonzalez residing at 980 GretOn Ct. Mattituck NY 11952 do hereby authorize Wayne Tu rett to apply on my behalf to tha TnWn of Cniithnlrl Riiilrlinp nanartment for approval as described herein. March 29 2021 Owner's Signature Date Jennifer Gonzalez Print Owner's Name 2 Siff tr BUILDING DEPARTMENT-Electrical Inspector 7 TOWN OF SOUTHOLD _ Town Hall Annex-54375 Main Road - PO Box 1179 , ' Southold, New York 11971-0959 FAX Telephone 75- rocerrsouth Idtowlnn ygov$OseandCr�sout o dtownny.gov --APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFOR TION (An Infomtadon Require Date: , Company Name: - _ --- - LO L-'LC C7.. _ . Name: YY7 (--2 - - - License No.: �. L_ - email: �.v i� L' �zt 00 /V .._ Address: Phone No.: 5 i i-1 v- ©G, JOB SITE INFORMATION (Ali Information Required) Name: . i Address: �! (2 .. _ TJ. .1�t G . ._ ��� ._r.._.. Cross Street: Phone No.: -qSQ qi 4 G I email: Bldg.Permit#: �;.�{ J _ Tax Map District: 1000- Section: Block: . �/. Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) LI-U i Y:-;,,I iv _ Q i3 A-v--zF f12 v 7 21 2c L4 ! S 1M��✓ 7 (.TZT127 c - Circle All That Apply: Is job ready for inspection?: YE I Rough In :F:inal Do you need a Temp Certificate?: ES /gNO Issued On.. Temp Information: (All information required) Service Size Ph 3 Ph Size: _ _A #Meters Old Meter#: New Service- Fire Reconnect-Flood Reconnect-Service Reconnected-Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N 'nfmtio . �Ad itional I C PAYMENT-DUE WITH APPLICATION Request for Inspection FormAs a _ TOWN OF SOU €SOLD., Town ball kni��x - 540. �i� ��ad f PO �c� ��?� D0 b�"i nj �e 1 f ��li t�v7 -{.i`9590i vi. i! ea. el rt+ 'n3<. �.F. •-31: v�•r,^" -s-3 d.-�r,i-i=`:'6's •(i�t., PAL Iu ION FOR ELECTRICAL (go 1NSI���T11QN1I L `CT # IA I FO T I A ON ,nitinfbrmavon required; Date: !� I', P O .L I I Company Name. ;q S Name: "Ze License No.: -7 �� eri�ail: �S ���{( � ��• 6�fw r Address: �ev > ,S — s��� a c.. E Phone No.: JOB SITE INFORMATION (Ail information Required; Name: 0AJ t S i ;address: 80 �5 112_lef®oly C_r /�14 Phone No.- Bidga-Permit- it (2 tl L�ii21C.Gi!• j s Tal I`0lap Dfstr:cr: 1000 Section: Block-. Lc : � BRIEF DESCRIPTION OF WORK {Please Print Cleari0 �01i� Circle All That Apply: Is job ready for inspection?: YES ' NO Rough In nal ®a you need a Temp Certificate?.- YFS C issued On ffe'7riipp anfo ,boon All information required;l Service Size 1 Ph 3 Phi Size: A # ivieters Old Meter# New Service - Fire Reconrec -,FiQad Reeonnec. - Service Reconnected - Undergrou nd - Ove r�eaL a , # nderaround Laterals ; 2 H Frame Pole or' done on Service? i gU1 vl ? ; additional information: ENT DUE A0 . .,"AT[vy -SelGam'' _. ,\�' ate ° Request;6r Ins,. M.x �`� s PERMIT# Switches t Outlets G F I's ` SurfaTell f Sconces ,y{� ,�0 H H's UC Lts Fans Fridge HW Exhaust I�C Oven Dryer 6,PA Smokes �I V� DW Service Carbon Micro Generator Combo I Cooktop Transfer AC AH I ' Mini Special: jy1.I11.0 l � f Comments sovqFF /r BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD ® '` Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802- FAX (631) 765-9502 rogerr _southoldtownny.gov— seand(&-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 11/18/21 Company Name: Anything Electric & Contracting Inc. Electrician's Name: Donald Welch License No.: 5220-ME Elec. email:anythingelectricny@gmail.com Elec. Phone No: 631-433-8602 ED I request an email copy of Certificate of Compliance Elec. Address.: 1520 Pine Ave Bohemia, NY 11716 JOB SITE INFORMATION (All Information Required) Name: Halbreich Address: 4955 Skunk Lane Cutchogue, NY Cross Street: Phone No.: Bldg.Permit#: 46421 email: Tax Map District: 1000 Section: 70 Block: Lot: S BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Wired small office on back of house. Square Footage: 1200 Circle All That Apply: Is job ready for inspection?: 0 YES❑NO a Rough In ❑ Final Do you need a Temp Certificate?: YES R NO Issued On Temp Information: (AII information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service Fire Reconnect[]Flood Reconnect[]Service Reconnect[]Underground[]Overhead #Underground Laterals 1 2 D H Frame M Pole Work done on Service? MY N Additional Information: Need roughing inspection ASAP PAYMENT DUE WITH APPLICATION d I J00V l3 ..s p rd _�tE 1000'107 -3.8 LOT 10 vElvV ptf000WN _� MAP OF 1 - GRETON ESTATES To WATER MAIN _ FILED. SEPTEMBER 20, 1996 — MAP #.6447 yf6y61' 1000'107'm•�3.4 _�--� 1 SITUATE SCTMJ 1000-107-02-4.3 ' puBUC`++� you - Im MATTITUCK VACANT g�IEus-�- 2ND FLOOR `� TOWN OF SOUTHOLD S —�- SUFFOLK COUNTY, N.Y. g8'41'0�- 5 BEDROOMS ADDITION M 1 �52-S N 1st FL 1,100 SF Ay OBNAY `� 3 b NOTES. N 2nd FL 1,175 SF G1N 1 O 1 gN Oty GFA Z275 SF 1 �+ , b,r,, 1. PROPERTY KNOWN AS TAX MAP# 1000E107-02-3.5 r02 W/PARTIAL BASEM CIA 2. LOT AREA =52,898 SOFT. (1.274 ACRE(S)) 8'DIAM.x 12'EFF. F.F.41.4 49, SF ``� 1 D09H LEACHING POOL o B 49 B- 3 C.0 1 WSEK'ACE 1 •y,2 F° y CEO �1 9-80 4'0 0 L AS-BUILT CROSSOVER A-37 1.500 GAL r r 1 PIPE B-JB SEPTIC TANK 0 DECK I w 3 78 86.00'00' 1r 1 R-21 -0 7 6 6 128EFF.DEPTH OSOIL 1 co 1" LEACHING POOL BORING 39 4 MASONRY 1 4 1 SCTMS 1000-107-02-9.1 r 980 GRETON CT., MATTITUCK, NY PUBUC WATER DWEWNG � 1 1 1 , SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES 1 1 APPROVAL OF CONSTRUCTED WORKS FOR Y ASINOLE FAMILY RESIDENCE ROY K. REI7IG, P.E. 1 MAR. 27. 2621 Date T/821 H.S.Ref.Na. Hzl-076e ' TOP SOIL (PT) _ 1 .' The sewage disposal and water supply facilites at this location have been 2.7' PALE BROWN SILTY 1 a SCMj 1000-107-03-2 Inspected and/or certified by this Department or other agences and found SAND (SM) � `� VACANT to be satisfactary FORA MAXIMUM OF 5 BEDROOMS. 5.0' BROWN SAND AND EQUIP, � _S 61'64'f0" F SOME GRAVEL(SP) 1.09, CRAIG KNEPPER,P.E.,CHIEF ` Offim of Wastewater Management , 1 Otv .9 9 17.0' j a•7 9� � 6. /SCM PU000-110E-02-15 11 SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES 9.0' LIGHT BROWN SAND DWELLING WATER G AND SOME GRAVEL (GP) 1 ,/� b ,,/, `1 11, R.q�sOP�NEW DANIEL R. FALASCO, P.E., P.C. NO,WATER FOUND 1 -/ 1 CONSULTING ENGINEER TEST HOLE DATA �1 d� 1 N.T.S. SCTMa 1000E107-02-14 1 94 STEUBEN BLVD., NESCONSET. NY 11767 $6 PUBUC WATER DWELLING Cy 2 (516)317-7209 � t D SCMp 1000E107-02-13 n�P a 0569 99 �� DATE SCALE DRAWING N0. 1 PUBLIC WATER 1 ROfESS10NP�' �� DWELLING6-9-21 1"=40' YORK STATE Compensation Workers' CERTIFICATE OF INSURANCE COVERAGE --. STATE Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured GABRIELSEN BUILDERS LLC 631-722-5130 P.O.BOX 317 JAMESPORT,NY 11947 1c.Federal Employer Identification Number of Insured Work Location of Insured(ONyrequiredifcoverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wmp-Up Policy) 203687759 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold Building Department 54375 NY-25 3b.Policy Number of Entity Listed in Box"1a" Southold,NY 11971 DBL244040 3c.Policy effective period 11/28/2020 to 11/27/2021 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above.. Date Signed 5/7/2021 By wid 4 (Signature of Insurance carrier's authorized representative or NYS Ucensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law.It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or 5B of Part i has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) elsll'iiui1i2i0oi1iiii(i10iai17)ii�l� afrs, •t HOME kz l ROBER.T E.GABR€ELSE1 tJ,i7.717.t�JJ tlCltttC I GABR�ELSEN'BUILUERS LLG' bearer is duly I'ce sed y t e Cou ty of su o `license Number: H 365.17 Rosalie Drago Issued: Q2/0312005 ' Gom essio a `,Ex,pires:, ;, 02/01/2023 1 ; PORK Workers' CERTIFICATE OF STATE Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Gabrielsen Builders LLC 631-722-5130 PO Box 317 1c.NYS Unemployment Insurance Employer Registration Number of Jamesport,NY 11947 Insured Work Location of Insured(Only required If coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Farm Family Casually Insurance Co Town of Southold Building Department 3b.Policy Number of Entity Listed in Box"1a" 54373 NY-25 3152W8527 Southold,NY 11971 3c.Policy effective period 11/28/2020 to 11/28/2021 3d.The Proprietor,Partners or Executive Officers are included.(Only check box if all partnerslofficers included) XQ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation Insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the and of the policy effective period? EJYES ❑x NO This certificate is Issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy Indicated on this form,If the business continues to be named on a permit,license or contract Issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business Is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the Insurance carrier referenced above and that the named Insured has the coverage as depicted on this form. Approved by: (Print name of authorized representative or licensed agent of Insurance carrier) Approved by: F_Z - dL (Signature) (Date) Title: Telephone Number of authorized representative or licensed agent of insurance carrier. Please Note:Only insurance carriers and their licensed agents are authorized to Issue Form C-105.2.Insurance brokers are NOT authorized to Issue It. C405.2(945) www.wcb.ny.gov Workers' Compensation, Law Section 57. Restriction on issue of permits and the entering into contracts unless compensation is secured. 1. The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured I as provided by this chapter. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, notwithstanding any general or special statute',requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as'provided by this chapter. C405.2(945)REVERSE CERTIFICATE OF LIABILITY INSURANCE DATE 05/07127/2I021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Katie Jackson Brian Micena PHONE Fft (631)821-2200 ac Ne:(631)821-2296 45 Route 25A suite D2 EADDDREESS: Kate.Jackson@American-Naflonal.com Shoreham,NY 11786 INSU S AFFORDING COVERAGE NAICII INSURERA:Farm Family Casualty Insurance Company INSURED INSURER B Gabrielsen Builders LLC INSURERC: PO Box 317 INSURERD: INSURER E- JameSport NY 11947-0317 INSURERF: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER Mohr EFF MPM EXP LIMBS LTR A COMMERCIAL GENERAL LIABILITY 3152X2148 11/03/19 11/03/21 EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTIED CLAIMS MADE �OCCUR PREMISES ocarrence $ 1�.��� X Contractors Advantage MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER, GENERALAGGREGATE $ 2,000,000 X POLICY PRO- LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: $ A AUroMoaiLEuABiu-Y 3152C7227 02/06/20 02/06/22 COMBINd D SINGLE LIMIT $ 1,000,000 IANY AUTO BODILY INJURY(Per person) $ AOWNED UTOS ONLY X SCHEDULED BODILY INJURY(Per acciderd) $ ALITOS HIRED NON-OWNED PROPERTYDAMAGE $ x AUTOS ONLY X AUTOS ONLY accident $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED I I RETENTION $ A WORKERSCOMPENSATION 3152W8527 11/28/19 11/28/21 X I P N'E eER AND EMPLOYERS'LIABILITY ANYPROPRIETORIPARTNER/DECUTWE YIN NIA E.L EACH ACCIDENT $ 100,000 OFFICERIMEMBEREXCLUDEDT (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 100,000 It yes describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,maybe attached IF more space Is required) Residential Carpentry CERTIFICATE HOLDER CANCELLATION Town of Southold Building Department SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Route 25 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Box 11779 ACCORDANCE WITH THE POLICY PROVISIONS. Southold, NY 11971 AUMOMMO REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD - YOR< workers'STATE Compensation CERTIFICATE OF INSURANCE COVERAGE --. Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured GABRIELSEN BUILDERS LLC 631-722-5130 P.O.BOX 317 JAMESPORT,NY 11947 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(onlyrequired if coverage is spaclficallylimiled to certain locations in New York State,i.e.,Wrap-Up Policy) 203687759 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShetterPoint Lrrfe Insurance Company Town of Southold Building Department 54375 NY-25 3b.Policy Number of Entity Listed in Box•1a' DBL244040 Southold,NY 11971 3c.Policy effective period 11/28/2020 to 11/27/2021 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. 0 C.Paid family leave benefits only. 5. Policy covers: A.All of the employers employees eligible under the NYS Disability and Paid Family gave Benefits Law. B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described aove. Date Signed 5/7/2021 By (Wo. (Signature of insurance carriers authorized representative or NYS Ucensed Insurance Agent of that Insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law.It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or 5B of Part i has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB420.1 (10-17) IIIII'11°-1�2�0��1°°(10�-17)°III 2019.00 980 GRETON COURT lSl 1 FILING SET-REVA 2021.04.15 2 9 9 0 , 80 1 U P, MATTITUCK, NY FILING SET a REV. ARCHITECT THE TURETT COLLABORATIVE _ �`E 277 BROADWAY, STUDIO 1300 N EW YORK, NY 10007 APPROVED AS NOTED I 212.965.1244 DATE: B.P.# FEE:1' 139.L BY: NOTIFY BUILDING DEPARTMENT AT C 755 1802 8 AM TO 4 PM FOR THE SHEET LIST Fc._s7WING INSPECTIONS: CONSULTANTS 1. r OUNDATION - TWO REQUIRED F^R POURED CONCRETE 2. :H! - FRAMING & PLUMBING ARCHITECT Z-001 RV \ T-000 COVER SHEET 3. iM:..�LATION THE TURETT COLLABORATIVE 4. FINAL - CONSTRUCTION MUST 277 BROADWAY, STUDIO 1300 Z-002 SEPTIC PLAN BE COMPLETE FOR C.O. C ALL CONSTRUCTION SHALL MEET THE NEW YORK, NY 10007 Z-003 SITE PLAN REQUIREMENTS OF THE CODES OF NEW 212.965.1244 G-001 GENERAL NOTES YORK STATE. NOT RESPONSIBLE FOR G-002 SYMBOLS AND ABBREVIATIONS DESIGN OR CONSTRUCTION ERRORS. MEP + FP ENGINEER DM-101 DEMOLITION PLAN - FIRST FLOOR XXXX DM-102 DEMOLITION PLAN - SECOND FLOOR XXXX DM-103 DEMOLITION PLAN - ROOF XXXX CA-101 CONSTRUCTION PLAN - FIRST FLOOR XXXX A-102 CONSTRUCTION PLAN -SECOND FLOOR CC''`�!'r'L`l WITH ALL CODES Oi= NEW YORK STATE & TOWN CODES LIGHTING CONSULTANT C A-103 CONSTRUCTION PLAN - ROOF A-200 BUILDING ELEVATIONS AS REQUIRED AND CONDITIONS OF XXXX SOUTHOLD TOWN ZBA XXXX A-201 BUILDING ELEVATIONS A-203 BUILDING ELEVATIONS SOUTuOLD TOWN PLANNING BOARD XXXX XXXX CA-301 BUILDING SECTIONS SGUTHOLDTOWNTRUSTEES A-400 DETAIL WALL SECTIONS �J.`i .DEC CA-601 PARTITION TYPES A-700 DOOR AND WINDOW SCHEDULE RETAIN STORM WATER RUNOFF S-101 FRAMING PLANS- FIRST FLOOR FRAMING PURSUANT TO CHAPTER 236 "acre re arati S-102 FRAMING PLANS- SECOND FLOOR FRAMING OF THE TOWN CODE. p Q� required as per S-103 FRAMING PLANS-ATTIC RIYS Code S-105 FRAMING PLANS - ROOF Must provide Manual,,, D,J and S as per NYS Energy Code SUSS Pj,gCARDiNG R1:QUIR FD to Chvtcr fm o4th'--TormCoe- THE: TURETT COLLACORATIVE ; PLUi'vii3ER C`RTIFICATION 0�V t-r-AD CONTENT BEFORE r :- :: OF OCCUPANCY IOT �. DRAWING TITLE PLtliv7L r"� 'T/r-ICATION ON LEAD CONTENT BEFORE R'IFICATE OF OCCUPANCY �OLDER USED IN W4 TI-R COVER SHEET SU-r PL YSYSTEM CG,,r!' r _ 1 ICY 7 EXCEED 2110 OF 1;0 _ STAMP& SIGNATURE PROJ. NO.: XXXX D A�,O DATE: 04/15/2021 SCE FANT / SCALE: SHT. NO.: s (P� 16090 � TmOOO �F OF IN 2019.00 980 GRETON COURT SS�E:1Rf�S�01Q—�f-�\�- 1 FILING SET- REV"1 l 2021.04.15 .. vPF,.I j ,Rr ,. LOT 10 a AP OP URETON ESTATES FILER, SEMEMBER 20. f996 JIMP #es,, 6447 IATE 1`041 "Oplu" E cc 1 SITU HATTITUCK R. 4 �. �. . Ar OF SOUTHOLD ILI- ! brFFOLK COUNTY, K. Y. � Y IJ .Vf 7 Y� C T 1 , 2 CONSULTANTS IN ARCHITECT ` THE TURETT COLLABORATIVE u . . . LOT" FA ° e� T'8 a . 1.21 k :gtgcz 277 BROADWAY, STUDIO 1300 " . . THIS l _ ' PREPAREDf NEWYORK NY 10007 I — ' L . � . U5 INC, MM WEIE _ S3 ROWED TI 707Ad— STATION. 212.965.1244 • x PPOPERTY C , % WAPE N PAR'T OF TT S .� TAN, e � J .... .. r L �-mi l n -�, e , mp E; A v"' 1 c ti e A .� ��" 4 7 *76h *Tee .. -�A717, • ��T t eu u «. t-.�5' .. .fit` ,p y r r g ' ' } 7u u w e� �►' 1��.�e� a 11 U�^> any \°"�,01 `�` wg„`�`� SR "�,� �•�i F P"s�w.ai` ":9 U E#''., .xii,A n S �r Ste°,,«� i r yc ��wr i,d°`'.F°�� ;,dy�.�}.:�!<..o..: �,'k'.. 3:'� S...tro �'�.'��� k� LIE>R 5 r : ? ' a w "? " .qe 3 . 91 ` LL . .." m "F' f�`' .. E'i. S"k.xs ASe� ..: k='.. Ag- e3' ..Y•� 1 „� � � .`� 'ye,�'= ��Ya«��"` � �a=: >'�C`•`.*Ca.��gi�"�"'b ' _ '' S'^'R.n ��`� � .ad� �' �e.<S�S:. �F4. � R AN �;, as �r a' r¢ 4 .: 1' .., r".."..` ? a�;. �' S.' 'c.�s .'e, •, �: a� flu lull d ,� y � T S a7� m, 71 x.>�w ti Ott' u ae �. pg+ g• �,•��a �,aAF ker @ A ,�M.ate,,a�$�. �^... 7 F .�.a `a���'����':, a�! L�i t�^ Oak JUMIFER M. GONZ lam. AR D HLrZi EM70,1 11 06 iD men, ai k N Rye ,xD�,4„ Sy 4 A 11 C IYA E,1, 1 1�fil, ff"Icl: Jk� ky LAND '1�4�]*��LIRR z ING '10 T: PtZAISS 11A4 i E' Ehr-n TUR TTARC COM C c k31 6 �., a DRAWING TITLE a p� E CEO T NR V� "otIImE r. * p e= .. R O C A � JQA K SURVEY SURIXYr-D 5)� DR NIM BY: SKEET: 1 = MIN 1 7 1 Ed - STAMP &SIGNATURE PROJ. NO.: XXXX D ARC DATE: 04/15/2021 �SJEFAry tv�'�'/ SCALE: SHT. NO.: 76090 (�� zwool OF IN 2019.00 980 GRETON COURT 7SET 1 FI -REV.1 2021.04.15 r Lo Fin 110 ' � R �, A AP OF GRETON El, "�TATE-S • ° T ! F t ILFT.�^,i..fBER 20o 1996 dad ieel? 1 D. Wpm .. S,ITUA TE lea sm cry 4 "�, _`i � W MA TTITUCK 1r 9 . I avow, # '&mot• Y. 4 — . • » s - = - P O _ itt, FL 1.100 SF �." ROB X EMNEfry + r � �{ I� CONSULTANTS r � EXIST NC. 8.' co . 0 € 1 F If . . $... I m .. .� ... ARCHITECT TO F �� , . CIE �q .. €` ... _• . THE TURETT COLLABORATIVE . wtv;lir. 3 a �u. ._ a vm .. ? � Y, STUDIO a ;r� 1 277 BROADWA O 1300 + _ �` d ^ NEW YORK NY 10007 R .. ° 1 ► � 212.965.1244 p ens CROSS w Y ` ' 5a. a'� #E 3 .e��A A $.�:�:x.8 Firm a R"• a f Y "�>eE aspr-aDf FIRE Wil^�• F25.66 I" .. lim. NG LE�.rlNc Poopco ; ~n iJ , .Y T' % f�. S �� r HID hO i a h'1 5 6 ni ! C NY PuE I r L L110I,a � °\a y _ '4�N 4 r ��e •# .� � ^,� � � rr I L- „r fir'° I L YNul 1 P K C RE ° - a — 1 2. PALE �� S �.. ��swNlD (Ski) W9fN!Tl .. 'S:'4, l":�:�xrt.�.yr`x`.• xM.S z.�;.'^'..i�^2`r�:Y ^�.Rk.` 4+vy....px:,w.: ...�.:e ..i' \C:•..._�4�a $... .�'.w, r SOME GRAVEL Roc ms SPA � � goo, � .� tt. ° e 7_01, . M E �. r 10.G' L11 17 E "��'I' C p 4 d SOME ',�i':l�:n��d THE Ap T ag�y �O ay f �E V a � i r\ D 'A' I EL FA L C roE p .. NO WATER J, CONSULTING ENGINEER ... Tom ._ e el, tCl , 10ID— 7 02-1 r�, a'. 4 � BLVD... NSSCONS Tj NY 11 7 D W: f, " .� .� DRAWING TITLE �,.�._LLlhd ,� DR I. DATE .. � ....._. .. ... . . A. . wl NRIIG KID, Punic c 1 op, 1 ellTq �wySa�yp ��y�/�p ; SEPTIC PLAN mawAmmxmm= id.r4l».r=,fWF '.c ,T.✓:14.M V;R i. '.'iRAi}A".ZY- w ' ..I..�h. 4i k w .R..c•c._ C;3 .On STAMP&SIGNATURE PROJ. NO.: xxxx D,qh,C DATE: 04/15/2021 C �SIEFAIVrG���F SCALE: SHT. NO.: 16090 Zm002ype� FOF rates 2019.00 980 GRETON COURT ss�1REv�s�O 1 FILING SET-REVA 2021.04.15 i i i i i i i 560 GRETON CT. - yl 745 GRETON CT. \ \ 3350 GRAND AVE. I i i 750 GRETON CT. � \ \ I - - -\- REAR YARD SETBACK - - - - - - - - - - - _ - - - - I i 2900 GRAND AVE, \ \ \ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I/' \ 980 GRETON CT. \ \ 0 15'-0" CONSULTANTS \ 2 STORY \ \ \ BLOCK:XX \ \ LOT NO.:XX \ \ I i ARCHITECT 2730 GRAND AVE. \ \ \ Q THE TURETT COLLABORATIVE 277 BROADWAY, STUDIO 1300 o I NEW YORK, NY 10007 EXISTING LOT COVERAGE:1628 SF } 1 212.965.1244 \ / PROPOSED LOT COVERAGE:1846 SF I 2360 GRAND AVE. 25'-0" 8'-6' I ` LOCATION PLAN \ \ \ \ ii K BUL RE Q. i DISTRICT R-40 \ N I MINIMUM REQUIREMENTS FOR 1-FAMILY DETACHED... I t n1 I i \ H< LOTSIZE (SQUARE0 \0 FEE T) 400 ,•. LOT WIDTH (FEET) 150 \ \ FRONT YARD SETBACK - ----- - -$- \— - - - \— — — - - —�- — — — - - ---- ... i LOT DEPTH (FEET) 175 FRONT YARD (FEET) 50 \ I SIDE YARD (FEET) 15 \ 1 I BOTH SIDE YARDS (FEET) 35 ,�.� \ 1 i REAR YARD (FEET) 50 LIVABLE FLOOR AREA (SQUARE FEET PER DWELLING UNIT) 850 \ o o I FRONT YARD SETBACK — - - - -\— — — — — — — — — — - - - - - � \ � , ( — MAXIMUM PERMITTED DIMENSIONS: LOT COVERAGE (PERCENT) 20 \ BUILDING HEIGHT(FEET) 35 \ NUMBER OF STORIES 21/2Lo I I I j THE TURETT COLLABORATIVE � I I I ROOF T: 2*Vg6li F. tl,,F0 TLJRFTTA4<p t0M 1/16"= 1'-0" DRAWING TITLE SITE PLAID STAMP &SIGNATURE PROJ. NO.: XX)CX D ARC DATE: 04/1512021 �SIEFAN lG� r/�� SCALE: As indicated SHT. NO.: I gyv1 y�. Zw003 '' 7v 0 o)z 1 � GENERAL NOTES BUILDING CODE NOTES 2019.00 980 GRETON COURT ;ENERGY CODE ANALYSIS 1 THE CONSTRUCTION NGMANAGER/GENERAL CONTRACTOR SHALL VERIFYEPANC ALL EXISTING CONDITIONS IN THE FIELD 1 ALL CONSTRUCTION WORK SHALL BE DONE IN ACCORDANCE WITH REQUIREMENTS OF THE FOLLOWS: [THE CHART DEMONSTRATES COMPLIANCE OF THIS PROJECT WITH APPLCIABLE REQUIREMENTS OF THE 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEWYORK STATE(ECCCNYS) (U.ON.ALL CODE PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD S_FCTIONS REFRENCED REFER 10 ECCCNYS) CONDITION',TO THE ARCHITECT. 2020 RESIDENTIAL CODE(RC)CODE OF NEW YORK STATE I BUILD'NG,YPE:RESIDENTIAL — ---- -- - 2 MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART -2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS) ICL:MA'EZONE as - UE1REVl$1�3 OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. -2020 EXISTING BUILDING CODE OF NEW YORK STATE C_omPLIANCE PRESCRIPTIVE-SECTIONS R401 THROUGH R404 VY 1 FILING SET-REVA 2021.04.15 3 THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL -SOUTHOLD TOWN CODE iM De>sr P�cN /� �/ ��>�sEDVAL ECCCNYS PRESCRIBED VALUE AUTHORITIES. 2 PER RC OF NEW YORK STATE R102.7.1 ADDITIONS,ALTERATIONS OR REPAIRS TO ANY STRUCTURE SHALL �� 4 ALL DIMENSIONS ARE FROM FINISHED WALLS AND PARTITIONS UNLESS OTHERWISE INDICATED.WRITTEN CONFORM TO THE REQUIREMENTS FOR A NEW STRUCTURE WITHOUT REQUIRING THE EXISTING STRUCTURE DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.WALLS SHOWN TO`ALIGN'SHALL BE FINISHED FLUSH TO COMPLY WITH THE REQUIREMENTS OF THE CODE.ADDITIONS,ALTERATIONS, REPAIRS AND RELOCATIONS CEILING,ROOF R-VALUE R-49(R-30 COMFORT BArr+R-ts COMFORT BArr+ NG(R-36)) PER ABLE R402.1.2,MN 49 AND SMOOTH WITH EXISTING WORK.AFTER THE PARTITION WALLS HAVE BEEN LAID OUT THE ARCHITECT IS TO BE SHALL NOT CAUSE AN EXISTING STRUCTURE TO BECOME UNSAFE OR ADVERSELY AFFECT THE R-sHEATHI NOTIFIED SO THAT WORK MAY BE INSPECTED AND APPROVED FOR CONFORMANCE WITH DESIGN BEFORE PERFORMANCE OF THE BUILDING. - - - - -- ------- - - PROCEEDING WITH ADDITIONAL CONSTRUCTION. 3 ALL ELECTRICAL WORK TO CONFORM TO LOCAL,STATE,AND N.E.C.AND UNDERWRITERS REQUIREMENTS. WOOD FRAMEWALLR-VAuIE R-2666))(R-23 ROCKWOOLINSULATION+RSHEATHING RE TABLE R4021.2,MN.R-20 CAVITY ORR-13(CAVITY)+R-5(CONTIN000S) 5 ALL WORK TO BE COORDINATED BY GENERAL CONTRACTOR UNLESS OTHERWISE NOTED.ANY SUBSTITUTE IN 4 ALL PLUMBING TO CONFORM TO LOCAL AND STATE CODES AND HEALTH DEPARTMENT REQUIREMENTS. --- -- -- - -- SPECIFICATIONSMUST BE SUBMITTED TO THE ARCHITECT FOR APPROVAL.SHOULD THE CONTRACTOR FIND ANY 5 ALL FRAMING TO CONFORM THE INTERNATIONAL BUILDING CODE, FOR HIGH WIND ZONE 3, 120 MPH,3 SECOND FLcoRR-VALUE R-23 PE ABLE R402.1.2,MN R-19 DISCREPANCIES,OMISSIONS,AMBIGUITIES,OR CONFLICTS IN ANY OF THE CONSTRUCTION DRAWINGS,OR BE IN GUST.SITE EXPOSURE B.ALL FRAMING HARDWARE TO BE SIMPSON STRONG TIE WITH A CONTINUOUS LOAD DOUBT AS TO THEIR MEANING,THEY MUST BRING THE QUESTION TO THE ATTENTION OF THE ARCHITECT PRIOR TO _-_ START OF CONSTRUCTION.THE ARCHITECT SHALL REVIEW THE QUESTION AND WHERE INFORMATION SOUGHT IS TRANSFER PATH FROM THE RAFTERS TO THE FOUNDATION. SHEATHING MUST BE NAILED TO TOP PLATE, NOT CLEARLY INDICATED OR SPECIFIED,WILL ISSUE A CLARIFYING ADDENDUM. NEITHER THE OWNER NOR THE OTHER PLATES,ALL STUD AND HEADERS, ROOF RAFTERS TO BE CLIPPED ACROSS THE PLATE TO THE STUD. CRAWL SPACE WALL R-vALUE R-13 R-13 ARCHITECT WILL BE RESPONSIBLE FOR VERBAL INSTRUCTIONS. 6 REQUIRED INSPECTIONS: _ 6 WRITTEN REQUEST MUST SUBMITTED FOR ANY PROPOSED CHANGES IN SCOPE OF THE WORK BY THE GENERAL -FOOTING AND FOUNDATION INSPECTION \ ! TR�\ ll T A,n R FENESTRAT N CTOR,M 0 ER TABLE R402.1.2,FENESTRATION U-FACTOR;MAX U-032 -FRAMING AND ROUGH-IN INSPECTION ] Fa�sTRaTIONu- aunsa AIN CONTRACTOR TO THE CLIENT AND ARCHITECT BEFORE ANY WORK IS STARTED,SUCH REQUESTS SHALL INDICATE -PLUMBING ROUGH-IN INSPECTION GLAZED FENESTRATION SHGC,MAX SHGC 0.40 PER TABLE R402.1.2,GLAZED FENESTRATION SHGC,MAX.SHGC 0.40 SCOPE OF WORK,COST,AND POSSIBLE DELAYS TO THE PROJECT. GAS ROUGH IN INSPECTION 7 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN -MECHANICAL ROUGH IN INSPECTION WHERE APPLICABLE AT AREAS OF NEW WORK,THE BUILDING THE PROPOSED CONSTRUCTION AREA AND ALL COMMON SPACES LEADING TO AND FROM THE CONSTRUCTION R4024 AIR LEAKAGEERMAL ENVELOPE CRITERIA SHALL COMPLY WITH ELECTRICAL INSPECTION TABLE AIR LEAKAGE AND CRITERIA AS INDICATED IN PER TABLE R4024:THE BUILDING THERMAL ENVELOPE SHALL LIMIT AIR LEAKAGE IN ACCORDANCE AREA.GENERAL CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR AIR LEAKAGE TABLE R402.4.1.1.JOINTS,PENETRATIONS,SEAMS, -FINAL INSPECTION CONNECTIONS TO BE SEALED,WRAPPED CAULKED, WITH REQUIREMENTS OF SECTION R402.4,AND CRITERIA INDICATED IN TABLE R402.4.1.1 DURING THE EXECUTION. 7 THE CONTRACTOR SHALL NOTIFY THE CODE OFFICIAL WHEN WORK IS READY FOR INSPECTION,AND SHALL A'RLEAKAGEAPED INAPPRovEDMANNERroMw MIZE THE DRAWINGS MAY NOT SHOW ALL ITEMS OR OBJECTS EXISTING AT THE SITE.THE CONTRACTOR MUST VERIFY AT PROVIDE ACCESS TO AND MEANS FOR INSPECTIONS. THE SITE ALL OBJECTS TO BE PRESERVED AND REPORT TO THE ARCHITECT ANY DISCREPANCIES OR QUESTIONABLE WINDOWS,SKYLIGHTS AND SLIDING DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NOT GREATER THAN 0 3 ITEMS. � CFM PER SQUARE FOOT. USE ALL MEANS NECESSARY TO PROTECT EXISTING OBJECTS DESIGNED TO REMAIN AND IN THE EVENT OF DAMAGE, j - PER TABLE R402.43, WINDOWS,SKYLIGHTS AND SLIDING DOORS SHALL HAVE AN AIR INFILTRATION IMMEDIATELY MAKE ALL REPAIRS AND REPLACEMENT NECESSARY TO THE APPROVAL OF THE ARCHITECT AT NO FENESTRATION AIR LEAKAGE SWINGING DOORS SHALL HAVE AN AIR LEAKAGE OF NOT RATE OF NOT GREATER THAN 0.3 CFM PER SQUARE FOOT,AND FOR SWINGING DOORS SHALL HAVE GREATER THAN 0 5 CFM PER SQUARE FOOT AN AIR LEAKAGE OF NOT GREATER THAN 0.5 CFM PER SQUARE FOOT,WHEN TESTED IN ADDITIONAL EXPENSE TO THE OWNER. ACCORDANCE WITH NFRC 400 OR AAMA/WDMA/CSA1011LS 2/A440 BY AN ACCREDITED,PRIOR TO COMMENCEMENT, CAREFULLY INSPECT THE ENTIRE SITE AND ALL OBJECTS DESIGNATED TO BE REMOVED INDEPENDENT LAB,AND LISTED AND LABELED BY THE MANUFACTURER AND TO BE PRESERVED,AS WELL AS ALL EXISTING UTILITIES.THE GENERAL CONTRACTOR SHALL REMOVE, WHEN TESTED AS NOTED IN THE NEXT COLUMN-> REROUTE/OR CAP OFF ALL UNUSED UTILITIES AFTER CHECKING WITH THE ARCHITECT.THESE ITEMS SHALL BE ENERGY CODE NOTES NOT LESS THAN 90%OF NEW PERMANENTLY INSTALLED PER R4041,NOT LESS THAN 90%OF NEW PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CAPPED OFF WITHIN EXISTING WALLS OR FLOORS. I ELECTRICAL POWER AND LIGHTING SYSTEMS LIGHTING FIXTURES SHALL CONTAIN ONLY 8 PARTITIONS: HIGH-EFFICACY LAMPS CONTAIN ONLY HIGH-EFFICACY LAMPS A.ALL OUTSIDE CORNERS AT MASONRY AND DRYWALL PARTITIONS SHALL HAVE METAL CORNER BEADS.TAPE AND 1 (U.O.N.,ALL CODE SECTIONS REFERENCED REFER TO 10 ECCCNYS) — CONSULTANTS SPACKLE SMOOTH WHERE REQUIRED.THREE COAT SPACKLE FINISH MIN. 2 TO THE BEST OF MY KNOWLEDGE,BELIEF AND PROFESSIONAL JUDGEMENT,THESE PLANS AND -B.ALL DEFECTIVE PLASTER AND/OR DRYWALL ON ADJACENT EXISTING WALLS SHALL BE CHOPPED OUT AND/OR SPECIFICATIONS ARE IN COMPLIANCE WITH THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW PATCHED FREE OF IRREGULARITIES AND SHALL MATCH ADJACENT WALLS IN FINISH AND THICKNESS. YORK STATE(ECCCNYS) ARCHITECT C.ALIGNMENT OF NEW WALL CONSTRUCTION TO EXISTING WALLS AND COLUMNS SHALL BE DONE IN A MANNER AS 3 ALSO SEE THE ENERGY CODE ANALYSIS CHART. TO VISIBLY ELIMINATE THE POINT OF CONTACT OR JOINT OF NEW AND EXISTING MATERIALS. THE TURETT COLLABORATIVE4 ALL ALTERATIONS WORK SHALL COMPLY WITH 2O20 NYSECCC 277 BROADWAY, STUDIO D.WHERE DEMOLITION HAS OCCURRED,CONTRACTOR SHALL FILL ALL HOLES,PATCH SMOOTH AND LEVEL ALL 5 PER ECCCNYS SECTION SHALL ALTERATIONS SHALL CONFORM TO ENERGY CODE REQUIREMENTS REMAINING SURFACES, INCLUDING WALLS,FLOORS,AND CEILINGS,SQUARE ALL CORNERS AND PROPERLY PREPARE ALL SURFACES TO RECEIVE FINISHES. WITHOUT REQUIRING THE UNALTERED PORTIONS OF THE EXISTING BUILDING OR EXISTING SYSTEM TO NEW YORK, NY 10007 COMPLY.ALTERATIONS SHALL NOT CREATE AN UNSAFE OR HAZARDOUS CONDITION OR OVERLOAD 212.965.1244 9 CLEAN UP:THE GENERAL CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATION OF MATERIAL AND ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING USES NOT DEBRIS.PREMISES SHALL BE LEFT BROOM CLEAN AT THE CLOSE OF EVERY WORK DAY.CONTRACTORS MUST MORE ENERGY THAN PRIOR EXISTING BUILDING SYSTEMS.TO ALTERATIONS. PROVIDE THEIR OWN DUMPSTERS.ALL PAINT BRUSHES,ETC,MUST BE CLEANED IN SLOP SINKS LOCATED EITHER IN 6 PER 907.1 OF EXISTING BUILDING CODE OF NEW YORK STATE,LEVEL 3 ALTERATIONS TO EXISTING THE BACK HALLWAYS OR IN THE BASEMENT.CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL UNWANTED EQUIPMENT AND DEBRIS AT THE COMPLETION OF CONSTRUCTION.AT THE COMPLETION OF THE WORK, BUILDINGS OR STRUCTURES ARE PERMITTED WITHOUT REQUIRING THE ENTIRE BUILDING OR STRUCTURE THE GENERAL CONTRACTOR SHALL PERFORM THE FOLLOWING CLEANING; TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE ECCCNYS.THE ALTERATIONS SHALL CONFORM TO THE ENERGY REQUIREMENTS OF THE ECCCNYS AS THEY RELATE TO NEW CONSTRUCTION ONLY. A.CLEAN FIXTURES, EQUIPMENT,FINISH HARDWARE,PAINTED AND DECORATED SURFACES,AND REMOVE MARKS, 7 PER R106,REQUIRED ENERGY CODE INSPECTIONS INCLUDE: STAINS,PAINT, DIRT,AND OTHER SOILING RESULTING FROM THE WORK OF THIS CONTRACT. -FRAMING AND ROUGH-IN INSPECTION 10 FIRE SAFETY: -PLUMBING AND ROUGH-IN INSPECTION ALL BUILDING MATERIALS STORED AT CONSTRUCTION AREA ARE TO BE SECURED IN A LOCKED AREA WITH ACCESS -MECHANICAL AND ROUGH-IN INSPECTION CONTROLLED BY THE OWNER AND/OR GENERAL CONTRACTOR. -FINAL INSPECTION ALL MATERIAL RO BE STORED IN AN ORDERLY FASHION. 8 THE CONTRACTOR SHALL NOTIFY THE CODE OFFICIAL WHEN WORK IS READY FOR INSPECTION,AND SHALL ALL FLAMMABLE MATERIALS ARE TO BE KEPT TIGHTLY SEALED IN THEIR ORIGINAL CONTAINERS.SUCH MATERIALS PROVIDE ACCESS TO AND MEANS FOR INSPECTIONS. SHALL BE KEPT AWAY FROM HEAT OR OPEN FLAMES. 9 PER R303.1.1,AN R-VALUE IDENTIFICATION MARK SHALL BE APPLIED BY THE MANUFACTURER TO EACH ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE. PIECE OF BUILDING THERMAL ENVELOPE INSULATION THAT IS 12 INCHES OR GREATER IN WIDTH, ALL ELECTRICAL POWER IS TO BE SHUT OFF WHERE THERE IS AN EXPOSED CONDUIT. ALTERNATELY,THE INSULATION INSTALLERS SHALL PROVIDE A CERTIFICATION THAT INDICATES THE TYPE, ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA IS TO BE SHUT OFF AFTER WORKING HOURS. MANUFACTURER AND R-VALUE ON INSULATION INSTALLED IN EACH ELEMENT OF THE BUILDING THERMAL GENERAL CONTRACTOR AT ALL TIMES SHALL MAKE SURE THERE IS NO LEAKAGE OF NATURAL GAS IN BUILDING,OR ENVELOPE. FOR BLOWN-IN OR SPRAYED FIBERGLASS AND CELLULOSE INSULATION,THE INITIAL INSTALLED ANY OTHER FLAMMABLE GAS USED IN CONSTRUCTION. DENSITY,COVERAGE AREA AND NUMBER OF BAGS INSTALLED SHALL BE INDICATED ON THE GENERAL CONTRACTOR SHALL NOT BURN ANY DEBRIS OR MAINTAIN ANY OPEN FLAMES ON THE SITE. CERTIFICATION. FOR SPRAYED POLYURETHANE FOAM(SFP)INSULATION,THE INSTALLED THICKNESS SHALL BE INDICATED ON THE CERTIFICATION.THE INSULATION INSTALLER SHALL SIGN, DATE AND POST THE CERTIFICATION IN A CONSPICUOUS LOCATION ON THE JOB SITE. 10 PER R303.1.1,AN R-VALUE MAINTENANCE INSTRUCTIONS SHALL BE FURNISHED FOR EQUIPMENT AND SYSTEMS THAT REQUIRE PREVENTIVE MAINTENANCE. REQUIRED REGULAR MAINTENANCE ACTIONS SHALL BE CLEARLY STATES AND INCORPORATED ON A READILY ACCESSIBLE LABEL.THE LABEL SHALL INCLUDE THE TITLE OR PUBLICATION NUMBER FOR THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF PRODUCT. 11 THE PERMANENT CERTIFICATE RE ENERGY EFFICIENT SHALL BE COMPLETED BY THE BUILDER OR OTHER APPROVED PARTY AND POSTED PER THE REQUIREMENTS OF ECCCNYS R401.3. 12 AT CEILINGS WITHOUT ATTIC SPACES, R VALUE OF ROOF/CEILING INSULATION MAY BE REDUCED TO R-30 PLUMBING NOTES AS PER R402.2.2 AND LIMITATIONS SET FORTH IN THAT SECTION. 13 PER R402.4.5,RECESSED LUMINAIRES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES,AND SHALL BE IC-RATED AND LABELED AS HAVING AND AIR LEAKAGE OF NOT GREATER THAN 2.0 CFM WHEN TESTED IN 1 ALL PLUMBING WORK SHALL BE PERFORMED BY A LICENSED PLUMBER. ACCORDANCE WITH ASTM E283 AT A PRESSURE DIFFERENTIAL OF 1.57 PSF. RECESSED LUMINAIRES SHALL 2 PLUMBER MUST CHECK EXISTING VVASTE AND VENT LINES TO BE FREE OF OBSTRUCTION. BE SEALED WITH A GASKET OR CAULKED BETWEEN THE HOUSING AND THE INTERIOR WALL OR CEILING 3 PROVIDE NEW ISOLATION VALVES AND BRANCH LINES FOR HOT AND COLD WATER SUPPLY FOR RENOVATED COVERING. BATHROOMS AND KITCHEN.ALL NEW COPPER PIPING SHALL BE PROVIDED FROM THE ISOLATION VALVE TO EACH FIXTURE.ALL NEW SHUTOFF VALVES TO BE PROVIDED AT EACH FIXTURE. ELECTRICAL NOTES 1 ALL ELECTRICAL WORK SHALL BE PERFORMED BY A NY STATE LICENSED ELECTRICIAN AND ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL JURISDICTION. CARBON MONOXIDE ALARM NOTESTHET , A13 , 1 CARBON MONOXIDE ALARMS SHALL BE INSTALLED AS REQUIRED BY R315-CARBON MONOXIDE ALARMS SMOKE DETECTOR NOTES ( DWELLING UNITS) SMOKE DETECTORS SHALL BE INSTALLED AS REQUIRED BY R314 SMOKE ALARMS AND HEAT DETECTION. •sa r 1 ,c A �z YoRk, NY #oeoa 2 DETECTOR; SHALL BE EITHER IONIZATION CHAMBERS OR PHOTOELECTRIC TYPES. 3 UNITS TO BE APPROVED BY BOARD)OF STANDARDS AND APPEALS ACCEPTED PURSUANT TO RULES AND REGULATIONS PROMULGATED BY THE COMMISSIONER OR LISTED BY AN ACCEPTABLE TESTING LABORATORY, DRAWING TITLE SUCH AS; UNDERWRITER'S LABORATORY,NOtRTHBROOK, ILLINOIS,MEA LAB.; CANADIAN STANDARD ASSOCIATION, ONTARIO,CANADA, UNDERWRITER'S LAB.OF CANADA, ONTARIO,CANADA, MEA. LAB. GENERAL NOTES 4 UNITS SHALL BE INSTALLED IN AREAS DESIGNATED ON PLANS;THEY SHALL BE LOCATED ON OR NEAR THE CEILINGS AND WITHIN 15'-0"OF ANY ROOMS USED FOR SLEEPING PURPOSES; FOR DWELLING UNITS WITH MULTIPLE LEVELS,WHEN ANY LEVEL HAS ONLY ONE MEANS OF EGRESS, UNITS SHALL BE PROVIDED AT ALL LEVELS. 5 SMOKE DETECTORS SHALL BE INSTALLED AS FOLLOWS; CEILING MOUNT-CLOSEST EDGE OF UNIT SHALL BE MINUMUM OF 4"FROM ANY WALL STAMP & SIGNATURE PROJ. NO.: XXXX ED ARc DATE: 04/15/2021 SCALE: Ark: -j SHT, NO.: 76 0 9CJ p� GmOO1 FOF IN 2019.00 980 GRETON COURT ANNOTATION SYMBOLS LEGEND MATERIAL LEGEND 1 Ref su V 1 FILING SET- REVA 2021,04.15 1 INTERIOR ELEVATION MARKER SOIL CUT TILE 1 Ref Ref — 9 1 RIGID INSULATION FINISH CONCRETE A101 EXTERIOR ELEVATION MARKER ;j:: WOOD SECTION STONE/TILE FACE Room name �. 101 ROOM TAG GLASS WOOD FACE SECTION HEAD V "` CUT STONE WOOD PLANK SIM 1 ENALRGED AREA CALLOUT STEEL ALUMINUM ELEVATION I DATUM MARKER �y CONSULTANTS DRAWING TITLE STRUCTURAL BRICK ARCHITECT CONCRETE THE TURETT COLLABORATIVE 277 BROADWAY, STUDIO 1300 830 DOOR TAG NEW YORK, NY 10007 212.965.1244 CENTERLINE OPARTITION TAG oxx WINDOW TAG FINISH TAG REVISION TAG ABBREVIIATIONS LIST ABBREVIATIONS LIST ABBREVIATIONS LIST ABBREVIATIONS LIST ABBREVIATIONS LIST ABBREVIATIONS LIST II i @ AT D.L. DOUBLE LAYER G.B. GRAB BAR MB.SDL. MARBLE SADDLE S.V. SERVICE VENT(DUCT) W/ WITH A.C., A/C AIR CONDITIONER UNIT D.R. DINING ROOM G.B.F.B. GYPSUM BOARD FURRED BEAM MBR MASTER BEDROOM !, S.W. SHEAR WALL W/D WASHER/DRYER A.C.T. ACOUSTIC CEILING TILE D.U. DWELLING UNIT G.B.H.C. GYPSUM BOARD HUNG CEILING MECH. MECHANICAL j 'SEP. SEPARATE W/0 WITHOUT A.D. AREA DRAIN D.W. DISHWASHER G.B.T.O. GYPSUM BOARD TRIMMED OPENING MET. METAL SH. SHOWER WD. WOOD A.F.F. ABOVE FINISH FLOOR DET. DETAIL G.C. GENERAL CONTRACTOR MIN. MINIMUM SHLV. SHELF, SHELVES WHRL. WHIRLPOOL A.N. AS NOTED DIA. DIAMETER G.E.P. GLOSS ENAMEL PAINT MISC. MISCELLANEOUS SIN. RD. SINGLE ROD WHRL.A.P. WHIRLPOOL ACCESS PANEL ADJ. ADJACENT DIAG. DIAGONAL GA. GAUGE MSNRY. MASONRY SL.S, D. SLIDING SHOWER DOORS WIND.DIM. WINDOW DIMENSION ADJUST. ADJUSTABLE DIM. DIMENSION GALV. GALVANIZED MTD. MOUNTED SPRLK. SPRINKLER WL.CAB. WALL CABINET ALUM. ALUMINUM DIR. DIRECTIONAL GEN. GENERAL N.C. NON-CORROSIVE !ST. STL. STAINLESS STEEL WM. WASHING MACHINE APT. APARTMENT DIV. DIVIDER GL, GLASS N.H.C. NO HUNG CEILING STAT. STATIONARY WR.GL. WIRE GLASS B. BATH DN. DOWN GR. GRADE N.I.C. NOT IN CONTRACT iSTL. STEEL WTR. RES. WATER RESISTANT _ B.CAB. BASE CABINET DR. DOOR. GRB.CH. GARBAGE CHUTE N.T.S. NOT TO SCALE STL.SD. STEEL SADDLE B.C. BRICK COURSES DRN. DRAIN GWB GYPSUM WALLBOARD NO.(#) NUMBER STOR. STORAGE B.F. BOILER FLUE DWG. DRAWING GYP. GYPSUM NOM. NOMINAL STR.JTS. STRUCTURAL JOINTS B.O.S. BOTTOM OF SLAB DX DRYER EXHAUST GYP. BD. DRYWALL CONSTRUCTION O.C. ON CENTER SURF. MTD. SURFACE MOUNTED B.R. BEDROOM EIK EAT IN KITCHEN H.B. HOSE BIB O.D. OUTSIDE DIMENSION SV CL. SERVICE CLOSET B.S.A. BOARD OF STANDARDS AND APPEALS ELEC. ELECTRIC(AL) H.C. HUNG CEILING O.F. OVERFLOW ! SV. EL. SERVICE ELEVATOR B.T. BATHTUB ELEC.HT. ELECTRIC HEATER H.M. HOLLOW METAL O.H. OPPOSITE HAND T.C. TOP OF COPING B.V.(B.E.) BATH VENT(BATH EXHAUST) ELEC.MET. ELECTRIC METER H.P. HIGH POINT O.T.B. OPEN TO BELOW ! T.F.O. TOP FLOOR ONLY BD. BOARD ELEV. ELEVATOR H.R. HAND RAIL OPEN SH, OPEN SHELF/SHELVES IT.O. TRIMMED OPENING BLDG. BUILDING ENAM.PT. ENAMEL PAINT H.V. HALL VENT(DUCT) OPG. OPENING !T.O.C. TOP OF CURB BLK. BLOCK EQ. EQUAL H.W. HOT WATER OPN.CAB. OPEN CABINET ! i T.O.S. TOP OF SLAB BM. BEAM EQUP. EQUIPMENT HT. HEIGHT OPP. OPPOSITE T.O.W. TOP OF WALL THE T U R E T T COLLABORATIVE : BOT. BOTTOM EST.GD. ESTABLISHED GRADE HVAC HEATING,VENTILATION,AIR CONDITIONING P.D. PUMP DISCHARGE T.R. TOP REGISTER BR. BRICK EXIT EXIT SIGN I.D. INSIDE DIAMETER P.H. PUBLIC HALL TEMP. TEMPERED BTW. BETWEEN EXIT LT. EXIT LIGHT I.G.B.C. INSULATED GYPSUM BOARD CEILING P.V. PUBLIC CORRIDOR VENT DUCT I TERR. TERRAllO C.CJ. CAULKED CONTROL JOINT EXP. EXPANSION INCL. INCLUDED, INCLUDING PART. PARTITION TEX.AC, PT. TEXTURED ACOUSTIC PAINT CAT. CAULK JOINT EXP.CONC, EXPOSED CONCRETE INSUL. INSULATION PC. PIECE ITH. THICK C.H. CONCRETE HARDENING EXP.JT, EXPANSION JOINT INT. INTERIOR PL. PLANTER ITRZ.SD. TERRAllO SADDLE C.I.S. CAST IRON SADDLE EXT. EXTERIOR JAN.CL. JANITOR CLOSET PL. BX. PLANTER BOX TV. TELEVISION C.J. CONTROL JOINT F.EX. FIRE EXTINGUISHER JT. JOINT PL. DRN. PLANTER DRAIN i TWL.BR. TOWEL BAR 2 x? >^d s�� r s ��; i t w as r ► v t c} C.L.L. CONTRACT LIMIT(LINE F.HT. FULL HEIGHT KIT. KITCHEN PLY. D. PLYWOOD DIVIDER �TX TOILET EXHAUST r� 2 12 4 f,5 12 4 A { E i N F o m U R F T r A R,, ' f 0 PA C.M.T. CORRUGATED METAL TIE F.RT. FIRE RATING KITTE KITCHENETTE POL. POLISHED TYP. TYPICAL C.O. CLEAN OUT F.A. INT. FRESH AIR INTAKE KX KITCHEN EXHAUST PR.SLR. PRIMER SEALER j U.C. UNDERCUT DRAWING TITLE C.R. CEILING REGISTER F.B. FACE BRICK L.D. LOUVER DOOR PRMD. FIL. PREMOLDED FILLED U.O.N. UNLESS OTHERWISE NOTED C.S. CAST STONE F.F.B.D. FULL FALSE BEAM DROP L.L.A. LOOSE LINTEL ABOVE PT. PTD. PAINTED URN. URNIAL C.T. CERAMIC TILE F.F.EL. FINISH FLOOR ELEVATION L.P. LOW POINT PWDR. POWDER ROOM V.C.B. VINYL COVE BASE C.W. COLD WATER F.H.M. FLUSH HOLLOW METAL L.R. LIVING ROOM R. ROOM V.C.J. VINYL CONTROL JOINT SYM BOLS AN D CAB. CABINET F.O. FLUSH OPENING LAM. LAIMINATED R.D. ROOF DRAIN IV.C.T. VINYL COMPOSITE TILE CAULK. CAULKING F.P. FIRE PROOF LAM.PL. LAIMINATED PLASTIC R.H. RANGE HOOD V.S.B. VINYL STRAIGHT BASE ABBREVIATIONS CEM. CEMENT F.P.C. FACTORY PRIME COAT LAV. LAVATORY R.W. RETAINING WALL iV.T. VINYL TILE CH. CHAMBER F.P.H.B. FROSTPROOF HOSE BIBB LDR. LEADER RAD. RADIATOR, RADIUS V.W.F. VINYL WALL FABRIC CL. CLOSET F.P.S.C. FIREPROOF SELF-CLOSING LIB. LIBRARY REC. RECESSED VENT. VENTILATION CLG. CEILING F.P.W.G. FIREPROOF WIRE GLASS LIN.CL. LINEN CLOSET REF. REFRIGERATOR VEST. VESTIBULE CMU CONCRETE MASONRY UNITS F.S.P. FIRE STANDPIPE LT.WT, LIGHTWEIGHT RESIL. RESILIENT VIF. VERIFY IN FIELD COL. COLUMN FFE FURNITURE FITTINGS EQUIPMENT M.B. MASTER BATHROOM RH. RECESSED HAMPER VIS, PNL. VISION PANEL STAMP &SIGNATURE PROD. NO.: �CXX CONC. CONCRETE FIN. FINISH(ED) M.E.A. MATERIAL&EQUIPMENT ACCEPTANCE DIV. RM. ROOM W.C. WATER CLOSET AR DATE: 04/15/2021 CONT. CONTINOUS FIN.FL. FINISH FLOOR M.L. METAL LINED S. SINK W.H. WEEP HOLE �E C i g �sTeFaro SCALE: As indicated CONV. CONVECTOR FIXT. FIXTURE M.L.V. METAL LOUVER VENT S.A. SLEEPING AREA W.I. WROUGHT IRON �`� ��F �' CORR. CORRIDOR FL. FLOOR M.O. MASONRY OPENING S.A.D. SMOKE ACTIVATED DOOR !W.I.C. WALK IN CLOSET SHT• NO.: COUNT. COUNTER FL. DR. FLOOR DRAIN M.T. MEN'S TOILET S.A.P. SIMULATED ACCOUSTICAL PAINT W.P. WATERPROOF CPT. CARPET FLASH. FLASHING M.W. MECHANICAL WATERPROOFING S.I.P. SOUND INSULATED PARTITION i W.R.G.B. WATER RESISTANT GYPSUM BOARD CRS. COURSE FOUND. FOUNDATION MAINT. MAINTAIN, MAINTENANCE S.O. SLAB OPENING W.S. WEATHER STRIPPING tSj, 7Gm D.F. DELIVERED FINISHED FYR. FOYER MAS. MASONRY S.O.P. SPRAY ON PAINT W.T. _ WO_M_EN'S TOILET -q� 509,4t7� 002 OF MAX. MAXIMUM S.T.C. SOUND TRANSMISSION CLASSIFICATION F NC`►• 2019.00 980 GRETON COURT Y IQ 1 FILING SET-REVA 2021.04.15 REMOVE EXISTING FENCE AND GATE _REMOVE EXISTING EXTERIOR WALL, WINDOWS,AND DOORS 16'-0" 16'-0" 5'-8" 16'-4112" I ti CONSULTANTS CLOSET ......... ._..... _.__. .... — . o no ' I' ARCHITECT II THE TURETT COLLABORATIVE (; REMOVE EXISTING PARTITONS FAMILYMEDROOP1 Jf �, 277 BROADWAY, STUDIO 1300 113NEW YORK, NY 000 212 9651244 CLOSET f MEP + FP ENGINEER -131 jIlk, XXXX XXXX } XXXX XXXX / BATHROOM GARAGE LIGHTING CONSULTANT LIVING ROOM ` 114 �`__r 123 I I r� � lrv��,� ; XXXX.s�CLOSET 1 i EN ;,j v XXXX i XXXX co c o DN : .:::.... . ..... I —_.. DINING ROOM KITCHEN ' DN 19 _ 9 J l O _ o I m -eme^ I DN I " HIE TUPETT COS LA130RATIVE : j 32'-0" 22'-0112" op I STY ANaAf:WAV 61tt6t0 1 YytaK.• av 1060 T: 2t2-4615 1244 1 F INF0aaTUPFTTAR k IC 0 M DRAWING TITLE DEMOLITION PLAN-FIRST FLOOR 1 114"= 1'-T DEMOLITION PLAN - FIRST FLOOR STAMP &SIGNATURE PROJ. NO.: XXXX DATE: 08/29/19 SCALE: 11411 = 1'-0" WD", m 1101 2019.00 980 GRETON COURT �E1R�V S1�3 1 FILING SET-REV.1 2021.04.15 REMOVE EXISTING CLOSET DOORS AND PARTITIONS 16-0" REMOVE EXISTING GARAGE ROOF y ------ , _ 12'-4 5/8" l'-9 7/8". 00, REMOVE EXISTING CLOSET DOORS AND PARTITIONS CONSULTANTS -� - -I - - ARCHITECT -__------7 -- -_- ;, THE TURETT COLLABORATIVE T - - ---s` j STUDIO 1300 . -_r , 277 BROADWAY, - r- --- NEW YORK, NY 10007 T - ER BEDROOM REMOVE EXISTING LAVATORY SINK 212 965 1244 ol ---._..._._..----._.._._... --- - I MEP + FP ENGINEER XXXX -- _..____.._...._..._ - — -- - XXXX ,.. �_'----- �� XXXX I li XXXX REMOVE EXISTING CLOSET DOORS AND PARTITIONS NG CONSULTANT I I 71 iI - I ..:. r..... ..__... ......... ..... . � i I ... ; XXXX I - I r. XXXX MASTER BATHROOPd — j li I XXXX -; XXXX I M '—oo ---- -- - - - I I - 3 --BEDROOM 3 - -� - M co } ; -7 -- ---I-------�-�� CLOSET - -- - - - --- ..I-- —- - 127 <...� II i 12'-5 1/8" THE TURETT COLLAF30RATIVE �DEMOLITIONPLAN-SECOND FLOOR �,l pk0kr'w&« *vw6la 1�eo I N*w 'foq§' �4v 144� x DRAWING TITLE DEMOLITION PLAN - SECOND FLOOR STAMP &SIGNATURE PROJ. NO.: XXXX DATE: 01/07/20 SCALE: 1/4" = 1'-0" DMml 02 2019.00 980 GRETON COURT SUEIRE�V�SI� 1 FILING SET-REV.1 2021.04.15 CONSULTANTS DEMOLISH EXISTING GARAGE ROOF ARCHITECTTHE TURETT COLLABORATIVE 277 BROADWAY, STUDIO 1300 r NEW YORK, NY 10007 E , 212,965.1244 I r , MEP + FP ENGINEER XXXX ' XXXX XXXX XXXX LIGHTIN G CONSULTANT XXXX XXXX XXXX XXXX f o i f r T H g�e�+ V R F T COLLABORATIVE : I 1 ;dPY oko,'s30wit'r 610bsti 'flag f Nib 'rope ' Nv 1000"P T: 2*2.965 4244 t E: t t asa7lt t'T E tti t DRAWING TITLE DEMOLITION PLAN - ROOF STAMP &SIGNATURE PROD. NO.: XXXX - DEMOLITION PLAN-ROOF SCALE: 1141101''00" D" M®10 3 A 2019.00 980 GRETON COURT V 0 1 FILING SET-REV-1 2021.04.15 3� 2 A 203 A 203 A-301 A-301 � 3 1 5'.8'I 16'-41/2" V.I.F;. V.I.F. NEW OUTDOOR SHOWER REFER TO INTERIOR DESIGN DRAWINGS FOR MORE INFO.RE: 2' 10 1/4" 10 8" 2 10114" YOGA STUDIO ELEVATIONS NEW IPE WOOD TERRACE - STEP NEW 1R 6 PER RISER NEW POWDER ROOM. REFER TO INTERIOR DESIGN °� DRAWINGS FOR MORE INFO. RE: PLAN ID.100.1 -- � \ NEW WOOD FLOORS ON SLEEPERS i NEW PANTRY----\\� I I _._.. . I I I _ EL I I ----r 104 T----- — I I lI j o I I CONSULTANTS — --- ti I � ARCHITECT OGA STUDIO THE TURETT COLLABORATIVE EL.2' -o° _ ' 0 12a i 277 BROADWAY, STUDIO 1300 � I NEW YORK, NY 10007 _= 0 5 _ — 212.965.1244 n - L o P R OM T-4 POWDER \\ o i I 1 4- -- - A-301 17Aj I .I .: i A-202 2 1 1 I _ �J 2CD � I I r i -- c!, EL" II .. GARAGE ------ P I P I 3 LAUNDRY RO01 DN 120 A201zo 2v N -i t \\ I co --- -------------- --- gl -- �3 NEW CONC. PAD 4'W X 18"D X 3'H N i I NEW GARAGE DOOR ,. I I I I I o LL I -DN - I 5'- �4" ! 15'-21/8" VLFI. V.I.F. _... . ..................__. ... i 22'-01/2" REFER TO INTERIOR DESIGN DRAWINGS FOR i✓- ---- -- ---- -- - MORE INFO. RE: PLAN ID.100.1 V.I.F. THE TU ETT COOL IDORA` IVIE : 4 DA-2OO ,Flat e*1DABWAY vfvt l(f" il�dk°" I mfw T�t-K, Nv fo0ey 044 Fn aTV0ETTAftC4 Baps DRAWING TITLE E n CONSTRUCTION PLAN-FIRST FLOOR 114 - 1-0 CONSTRUCTION PLAN - FIRST FLOOR STAMP&SIGNATURE PROJ. NO.: xxxx D ARC DATE: 04/15/2021 �STEFAN TG�y�� SCALE: 114" = 1'-0" SHT. NO.: �9 9 sqT 76 09a A�Q�� 1u' .Op NEON 2019.00 980 GRETON COURT JSSUEIREVISION "IE i FILING SET-REV 1 2 FILING SET\REV 2 A-203 A-203 3 2 2'-10 114' 10'.81 Z-10 114' Z-w 7-81 T-r Z-w REFER TO INTERIOR DESIGN DRAWINGS FOR MORE INFO RE. STUDIO ELEVATIONS ID.1 0 A- �Oa, A- --- " - ------ T ............... .................... _MASTER BEDROOM----------- ------- 201 CONSULTANTS ............... ARCHITECT HOME OFFICE --L-- -- N -------------- EW WOOD FLOORING ON NEW PLYWOOD SUBFLOOR ON THIS THE TURETT COLLABORATIVE .-r.i 1 5/v.1 4'-0 1/4" 7-2 Slor .............- . 277 BROADWAY,STUDIO 1300 2 ------------ NEWYORK,NY 10007 77 , NEW PRESSURE TREATED WOOD STAIR WITH WOOD 212.965.1244 -------------- ---- - ----- UPRIGHTS AND WOOD HAND RAIL 20.1'11 1 ............. 1 CLOSET 203Al 204, NASTIER DATHROO J�T 1\tSli 2M 16R @6 13/16-PER RISER REFER TO INTERIOR DESIGN DRAWINGS FORMORE INFO.RE MASTERBATHROOM 205 PLAN ID.100.2 2 1 0 ......................... 2 I z EXISTING STAIR TO 1 T O-G.--�-,CATHE CIG 3 � REMAIN- 2 7113-6 ... ....... NEW CLOSET WITH SHELF AND ROD AND PAIR OF CLOSET SET . . . . .. . . . EL.1 0 1/ 206A AT T- G 4CAT 2L4 Iq; DOORS _1 CLOSET- : A 0 -------------- HIS 0 -LEDROOM NEW WOOD FLOORING ON NEW PLYWOOD SUBFLOOR ON T ----- . ............ s2 KIDS BAT! BEDROOM 3 -r2 ............ .......... .............. 2008 20 (20t NEW 3 FIXTURE(TUB,LAVATORY,AND TOILET) BATHROOM REFER TO INTERIOR DESIGN DRAWINGS FOR MORE INFO.RE BATHROOM wr 9-10 3181 O 5 2Z-0 IIT NEW SKYLIGHT T THE TURETT COLLABORATIVE: n12. DRAWING TITLE CONSTRUCTION PLAN-SECOND FLOOR tv 114-11-01, CONSTRUCTION PLAN SECOND FLOOR STAMP&SIGNATURE PROJ.NO.: xxxx cEREDgRO DATE: 0512512021 SCALE: 114"=V-O" SHT.NO.: 40 A 4 All 2019.00 980 GRETON COURT v *N­--Nllv���� 1 FILING SET REV.1 2021.04.15 <---3 2 3 ol A-301 <A- 01) 3 2 16-4 1/2" or 2'-10 1/4" 10--8" 2'-10 1/4" oe 2'-8" 2'-8" 2'-8" 2'-8" REFER TO INTERIOR DESIGN DRAWINGS FOR MORE INFO. RE: STUDIO ELEVATIONS ID.102.4 7 C2O 2) C2 0 3� JI F------ �O�5 MASTER BEDROOM 201 CONSULTANTS b ST6O t- ARCHITECT T-1 15/8" 4'-0 1/4" 2'-2 5/8" NEW WOOD FLOORING ON NEW PLYWOOD SUBFLOOR ON THIS THE TURETT COLLABORATIVE fN 277 BROADWAY, STUDIO 1300 (20 -- =�� I I I NEW SLIDING PARTITON NEW YORK, NY 10007 - -- i NEW PRESSURE TREATED WOOD STAIR WITH WOOD 212.965.1244 212 ------------------ UPRIGHTS AND WOOD HAND RAIL 2P3) -CLOSET 203A 20-4-)­ 217 A-301 MASTER BATHROOM �01 HALL OFFICE 1 202 2(l) N� REFER TO INTERIOR DESIGN DRAWINGS bo 203 208 16R @6 13/16"PER RISER FOR MORE INFO. RE: MASTER BATHROOM 2 '-�LOSET 'T PLAN ID.100.2 4'-3 11/2 1/81, 6'-115/8" 8'-0 1/8" of 2038 2 (20�6 2 c) cl) (207 c? CATHEDRAL CLG Al 3 Al iFLAT CLG EXISTING STAIR TO REMAIN---- 'A DN! C21 CLOSET 4'-9 3/4" 6-2 7/8" -N4� A 00 NEW CLOSET WITH SHELF AND ROD AND PAR OF CLOSET 206A cli ................TT T EL. 1 l'-0 1/2 DOORS IlK", —N — - 213 214 r 'K ai�L CLOSET FLAT CLC 10, CATHEDRAL CLG c� c� 204A (Al Al I _2 Z� O -T�08 210 - --------------------- --- --------- NEW WOOD FLOORING ON NEW PLYWOOD SIJBFLOOR ON THIS BEDROOM ------- �0- KIDS F THROW"I q):::T2 2 204 20 7�LOSET Cl�2: It 7H L 7� t, O I BEDROOM 3 A A'Ak h,q,'u Co lno�I pp, .......................... .................................. NEW 3 FIXTURE(TUB,LAVATORY,AND TOILET) ji BATHROOM___—/ 5-11 rl/8" REFER TO INTERIOR DESIGN DRAWINGS FOR MORE INFO. RE: BATHROOM 14'-1 0 3/8" 102.5-- 2'-6" 22'-0 1/2" NEW SKYLIGHT---- THE TURETT COLLAVORATIVE . 4 (A-200) 21 Vy 04-1,4DfwAy $�vbn 1�00 f NOW '04"Ap, NY io0o"t DRAWING TITLE CONSTRUCTION PLAN SECOND FLOOR CONSTRUCTION PLAN SECOND FLOOR STAMP &SIGNATURE PROJ. NO.: xxxx D Ar?o DATE: 04115/2021 S[FFAIV SCALE: 1/4" 11.011 SHT. NO.: 40 02 160 13 OF Amlo" I 2019.00 980 GRETON COURT 7ISSUBIREV S 1 FILING SET-REVA 2021.04.15 i - t A' 203 A 203 3 2 21'-61/2" 2'-4 114" 11'-8" 2'-41/4" oe -- — [—NEW ASPHALT SHINGLES ROOF TO NEW ASPHALT SHINGLES ROOF MATCH EXISTING II ii 3 2 A-301� A-301 _ �......_-----_ ---- -- I _ z I I Q I CON WSULTANTS o ARCHITECT THE TURETT COLLABORATIVE 277 BROADWAY, STUDIO 1300 NEW YORK, NY 10007 212.965.1244 00 4 1 A 301 o A-301 ! I A-202 2 _ i ------ A 201 - Iop L9 1 301i 0 I i I � I I I I T-9" 10'-6" 3'-31/2" i THETl,1! RC- TT COLLABORATIVE : 8'-6" 21'-6 1/2" 4 I A-200 J CONSTRUCTION PLAN-ROOF / "� � � ` ' � � � It �-�1/4'�= V-0" (�b .12AG5 DRAWING TITLE CONSTRUCTION PLAN - ROOF STAMP &SIGNATURE PROJ. NO.: XXXX p,gRc DATE: 04/15/2021 �glEFANrG����� SCALE: 1/41' = 1'-0" SHT. NO.: s64Ip 76090 p� M 103 FOF'N � 2019.00 980 GRETON COURT <—A01 A-301 V �A 1 FILING SET—REV.1 2021.04.15 ROOF 24'-101/2" ROOF PROPOSAL _ _ - - - - - - - - - - - - -- - - - --- - --- - -- - - - - - - - - -- - - - - - - - - - -- - - - - 23'- 10" SECOND FLOOR CLG 191 -- - - - --- --- -- - - - -- - - - - - - i ROOF EXISTING GARAGE 18'-2" I , x. . r �u_.........,,..,,,,,.....,.__......_.__......__. CONSULTANTS ARCHITECT ,. _ � f THE TURETT COLLABORATIVE f 277 BROADWAY, STUDIO 1300 { g : NEW YORK, NY 10007 P 212.965.1244 i e` x GARAGE LEVEL x .. .............a..,,.,...,.,...,...a...,.,..........,. n.. GRADE 01.011 4 EXISTING EAST ELEVATION 1/4"= 1'-0" 3 2 A-301 A-301 ROOF 24'-10112" ROOF PROPOSAL_ - - - - - - - ---- - - -- - - - —NEW SKYLIGHT SECOND FLOOR CLG 4 _ T — NEW EAVE TRIM TO MATCH EX G 3 NEW CASEMENT WINDOWS THE TURETT COLLABORATIVE * I € NEW WOOD SIDING TO MATCH EXISTING a, ` NEW PRESSURE TREATED WOOD WITH WOOD UPRIGHTS AND SECOND FLOOR WOOD HAND RAIL W... E .................. . r `a.:as:.....•.. , _.__�� .. ...................._.,............,,,,,.. a,... "s ....._.....,,,.............._.�n...w._...,.. :::.:::,.:::::::..:-'...........m..._. --- T: 21� .'�6 5 1164 I F: 2�r O�a T U R F T T A O .C M ---- x x NEW GARAGE DOOR , x x � DRAWING TITLE .s r { i � I .._....�...�........ ._._.._. ... .. ... ..... i i E � i FIRST FLOOR BUILDING ELEVATIONS 21-011 C261 x. x ` x x x x :x=i x. x i ( x a.• .x >.. ..... .,a:...>,as..�...�..a...` ...., ., l.�.. ... ,. ..j. z , x =x { r .. GARAGE LEVEL -�� - 11 { t 0\ - - - _.-,.,.,........._.-..._._.._._-..... . . - ......._..... ..... -_. - - - - - _,... — _t 1 6 { „V i .`•'. ;_...; .. .,. .. ,k.Me,:>...:af.� �.. `xa " 3.'i ... .a�.6�3 vt(r'.`w..zw fksa .....,.,,,........_._._......._................ ..............,.e....._ �......,..,»....-..a.........,.>...ra:.Mer .•< .. .au.'r.a. va".a�'N'«>:.fAhv<t 'Ss aF� aw''.Yw'e ...w >. 'iA: _ 'x� �:�.`Mi.�°.sd . y GRADE _ _ .,,,....__. ,,,,,,..,w,, , ,..,,..,,W .,,, w__ ,._.,. _.01-011 . 5 :,.......� — .....V..W...,E STAMP &SIGNATURE PROD. NO.: XXXX D ARC, DATE: 04/15/2021 n EAST ELEVATION �`� �S�EFANT��'S/�� SCALE: 1/4" = 1'-0" - 1-0 SHT. NO.: 5 of 85 16090 ®� Aw200 FOF N 2019.00 980 GRETON COURT V 1 1 A-301 FILING SET-REVA 2021.04.15 I I ROOF 24'- 10112" - - - - -- - - - -- - -- - -- - --- -- ---- - ROOF PROPOSAL i 23'-10" - - REMOVE ROOFING SECOND FLOOR CLG - - - - - -- - -- - - -- --- - - -Y- - - - , - - ---- - --- - -ROOF EXISTING EXISTING GARAGE 18'-2" ----= REMOVE VENT REMOVE ROOFING " ! REMOVE SIDING j CONSULTANTS I fr ARCHITECT G THE TURETT COLLABORATIVE 277 BROADWAY, STUDIO 1300 NEW YORK, NY 10007 212.965,1244 GARAGE LEVEL wo...._�.................. L.... ".._.....................:.. 11-611 _GRADE ' 0'-p - - - - - - - - - --- -- - - - - - - - - - - - - - - - - - II n EXISTING NORTH ELEVATION U 114"= 1'.0" (1 A-301- jh I ROOF - - - - — - � - - - -- - -- - - - - - - -- - - - - -- 24 - - - - '-10112" RO PROPOSAL - - ✓ k.. Y— --- _. i NEW EAVE TRIM TO MATCH EXISTING _M NEW SIDING TO MATCH EXISTING ROOF EXISTING GARAGE ° .m 18'-2 = 217 "-- NEW EXTERIOR DOOR S= a I - ~~ x NEW PRESSURE TREATED WOOD STAIR WITH WOODTHE TURETT COLLABORATIVE : SECOND FLOOR UPRIGHTS AND WOOD HAND RAIL. STRUCTURAL SUPPROT _ 112 ._ _ _ __.._ -._ _ ._ _ _ _. _ ...-..._.._ _ --.- -- _ -- -'--- ..�...- ._. _. _.._...� _ _ BY WOOD POST 11'-0 " I .... I I PROVIDE NEW 16" D X 3'-6"W X 42"DEEP PAD FOR SUPPORT OF RISERS 1 I I7 *kns4€ wav 4-L`0s0 NwfA• Yo&lc, by 1'14 07 I ( 3 i I DRAWING TITLE FIRST FLOOR 2'-0" GARAGE LEVEL 1'-6" ,. � �..-.�� � __�__.. .w._..��_�__.". BUILDING ELEVATIONSGRADE _.. ... . .... _._..._.."_.__ ._.. - - - - - - -._ -__ __W. - - ---- - - -- - - 01.011 _..- - ry _ STAMP &SIGNATURE PROD. NO.: XXXX D ARG DATE: 04/15/2021 5 S' EFAIV r�R�i�t� SCALE: 114" = 1'-0„ 3 PROPOSED NORTH ELEVATION q s SHT. NO.: 114 - 10 s9T r6090 yq FOFF:NE`N 2019.00 980 GRETON COURT ss U"lrs 1 FILING SET—REV.1 2021,04.15 2 3 ROOF A 301 A-301 24'-101/2" - -- ROOF PROPOSAL ' ' SECOND FLOOR CLG \� 191.011 - - - - - - - - - -- - --- ' - --- - --- - --- :---- \- - - - - - - - - - ROOFEXISTINGGARAGE - - - - - - - - - - - - --- - - - — - --- == '� - - - - -- -__- � _ ._ - - - - - - - - - - - - - - --- -- - - - -- 18'-2" - - — x 1.. x } 4 { e E REMOVE EX'G GARGE ROOF — I REMOVE EX'G EXTERIOR WALL WITH _ ..., -......,. EAVE TRIM,WINDOW,SIDING,AND DOOR — m . .. $ CONSULTANTS x. e < x U NTS x _ x E v z REMOVE EX'G EXTERIOR GATE AND j .. .;, .:.._. _ ARCHITECT FENCE i• � ° � I � ':� ` � & �: i ,., : _ ; } g THE TURETT COLLABORATIVE 277 BROADWAY STUDIO 1300 < m _ ^,..._.,._._....,.... .4w_•_........_. .. .___..,.__.a_....:..._..^. . . . }} NEW YORK NY 10007 jh GARAGE LEVEL � .. . . . ...... . .... .. . . ..... . . . .. ... . ... .... .,....v�_� . ....�....... .. - ...��._._�.. ._.w_,_._.. ..�..�..._..._...._...._ .__......._._-..._.M.a._..�_...�.�...-. . . t - - - �� 212. 1 4.". - - -- - - 965, 2 4 4 "e GRADE - - - - - - - - - - - - - - - - - - - - -- - - - -- - - - - - -- - - - .�... 0'-0" - - n EXISTING WEST ELEVATION U 114" = 1'-0" 1 2 3 A-301 A-301 NEW EAVE TRIM TO MATCH EX'G i NEW CASEMENT WINDOW. TRIM TO MATCH EXISTING. 1 ROOF 2'-41/4" 6" 2'-8" 2'-8" 2'-8" 2'-8" 6" 2'-41/4" 24'- 101/2" �'��' �' �' �' - - - - - - - - --- - - - --- - --- - - -- -- — - — - — - — - - - - - - - - - — - — ROOF PROPOSAL F 1 E i e NEW ROOF IN SHINGLES TO MATCH EXISTING j I E NEW DORMER SECOND FLOOR CLG 1 I � ...�.. .__._....._...._.._......._.__..._...�..N-r�. .• �...•• S5 \ Y ^ ' � w<wwmuva, av�vu\uuauauuuw`x-v�mr«wavuuuuuuwwuaauu .� � x wuuu�uuuvuuuu NEW 2 STORY WINDOW WALL ASSEMBLY ,. .........., x 205 204 203 202 I01 I NEW PRESSURE TREATED WOOD I' a THE TURETT COLLABORATIVE : STAIR WITH WOOD UPRIGHTS AND I WOOD HAND RAIL _ _ ...._....._... E .. iI 213 214 215 2 v` J16 � I 14 II x.= I SECOND FLOOR .... ._.... ......_.......... ............_...... " } x , _...__ ......... m_._.w_�_ _. ......m.._._....__._...._.. . . } x x x i Pat'rCb4x'# URETTAH�CNd.CoM € I x E x NEW OUTDOOR SHOWER DRAWING TITLE fi I 102 .• 3 _ I .. ° ... NEW IPE WOOD TERRACETr jgS•........w.........,.ci..., a....,....«. _.. [ I ( f F to E ,. �*.P"., e `q•e� ����x d f i P � i � F ( �ro. FIRST FLOOR t ggg i i � i "�.�•>,•p`�,..�it \\E•S�I`I3 I 3, ; [ ,,``t � =s. I I ..:.�.wr,.w. ...:ems w: � .�. 3 afi & I € _ x BUILDING ELEVATIONS GARAGELEVEL x 1 -6 - - .. - -- - — - �........................._ .._........_._.._,... ..--._._....._...................__. ............._.M._._.._..___..._._._...... ... .... _w.._.. ....._._.. _ _......_...__....__ _ .._. - ^ E .....«..... ................. .r...,,..,...,,,.. .------------------ram................. ...........................,.�..... ...........�.....�,..... ....o...r.�...........»r.a..,...-.»............^..............., ... .....................E .... ....._ .._.... ... ......................GRADE ..................... .. ..... 01.011 NEW OUTDOOR SHOWER _NEW DOOR.TRIM TO MATCH EXISTING. STAMP &SIGNATURE PROJ. NO.: Xx(X �D ARC' DATE: 04/15/2021 �g(EFA/yr�R'S'iJ� SCALE: 1/4" = 1'-0" SHT. NO.: n WEST ELEVATION 16 0 913 p�� FOF N � 3 2019.00 980 GRETON COURT 2 A-301 A 301 MAX BUILDING HT_ - — - - — - - — - -35'_oil - - --- - ----- -- ---- - -- -- ----- -- ----- - ----- - - V REFER TO INTERIOR DESIGN DRAWINGS FOR MORE INFO. (LING SET-REV.1 2021.04.15 RE:STUDIO ELEVATIONS I D.102.4 REFER TO INTERIOR DESIGN DRAWINGS FOR MORE INFO, RE: RE: STUDIO ELEVATIONS ID.102.4 \ REFER TO INTERIOR DESIGN `\ DRAWINGS FOR MORE INFO. RE: MASTER BTH ELEVATIONS ID.102.3 ROOF - - - - - - _ - - - - - - - - - --- - --- - - -- - - - - - - - - — ROOF PROPOSAL _ _ ___ ____ _ __._ _ ___- __ _ _ ,:,,:, 231-1011 SECOND FLOOR CLG _ ._ _._ -_ __ >- - - - - - „ ,a, , - - - .. . .. - 19' 0 RO EXISTING GARAGE _ _ - 18'—2" j C20' 202 203 2 44 1 05 MASTER BATHROOM HALL i_ CLOSET OFFICE � STUDIO REFER TO INTERIOR DESIGN DRAWINGS _ — . -- .1 _ FOR MORE INFO. RE: POWDER ROOM I 2p2 r FD3 203A � 208 207 a a x� sy. a.. 4 x 20 ) i 217 -" � (zoi (202) CONSULTANTS SECOND FLOOR " ` _-_ w....wxxxwv , w,wwww: - - - - 77,77 - - - 11 01/2 < • ARCHITECT COLLABORATIVE .,x ' „ THE TURETT 277 BROADWAY, STUDIO 1300 NEW YORK, NY 10007 ` t , LIVING ROOM I BATHR00,lA� POWDER OOM 212.965.1244 ' ,_...._:• .m , : ,2, > GARAGE 117 R I 114 ' — 122 f f • a f , a a i i x FIRST FLOOR I ; «< F y 2 0 », .. .. .. < ..r a •.. .<. :., l ... ,.,, a<< .,•v .. .tea... w <.,..,.:;:,a.r .. �b,. :l\��e�, \\�. �.wxwnuveR��lr7m•�«: aw<~�-ice .=,.«.au.ww.,,;...,« •., ,>,•w �tx. ...,w.+a�waticcc.n.<.�`..�1<.aF ra "-ee«...:e.,. .F .wne ..w...aex @av Waa�..,,w.xw¢.mx .< .,x. .e»,. .. < a ....,..'.{ ,.� A< m E 11 G AGE LEVEL 0'-0" 1 BUILDING SECTION 1 1/4" = V-0" REFER TO INTERIOR DESIGN DRAWINGS FOR MORE INFO. RE: RE: 1 1 STUDIO ELEVATIONS ID.102.4 1 REFER TO INTERIOR DESIGN A-08 A-301 A-301 DRAWINGS FOR.MORE INFO. RE: REFER TO INTERIOR RE: STUDIO ELEVATIONS ID.102A DESIGN DRAWINGS FOR MORE INFO.':RE:AUGUST'S 7 REFER TO INTERIOR DESIGN BDR 102.6 A-400 DRAWINGS FOR MORE INFO. RE: BATHROOM 102.5 ROOF _ ROOF PROPOSAL - - RO_OFPROPOSAL- - �- - - - - - - -- - - - - - - - - - - - - - - - - - - -- - --- �J 23'- 10'"-- - - - - ---- - --- - - -�- - - - - - - - - - - - - - - _ .� _ � - - -- - -- - -- - - - = - P P� - 23 10 �� '- RJOF — I - - - - - - - - - - - - — - - - - - - - - - - - - - -- - -- --- - --- - - -- - --- - - - - - - - - - - - " N ROOF � _ --- - ,� 22'-81/4' � - - - - - - - - - I I 22 -81/4 _ SECOND—LOOK SECOND FLOOR CLG_ 19 ;0 EXISTING GARAGE — — — — — — — — — — - -- — ` ( ROOF EXSTING GARAGEa —f— I 18'-21 r THE TVR TT COLL1� S �3PATIVE ' 2 BEDROOM CLOSET 2 KIDS BATHROOM £' OFFICE STUDIO « 206 206A F a 205 208 , I i 207 I i a I 212 214211 211 SECOND FLOOR SECOND;LOOK ry « 11 01/2 65 1T E 0 TUP TT A x A400 r x.�P a � REFER TO INTERIOR DESIGN DRAWINGS P E i a FOR MORE INFO. RE:POWDER ROOM DRAWING TITLE REFER TO INTERIOR10 ID.102.1 �. DESIGN DRAWINGS FOR i MORE INFO. RE:YOGA , REFER TO INTERIOR DESIGN DRAWINGS I„ } FOR MORE INFO. RE: t 1 11 STUDIO ELEVATIONS. GARAGE YOGA STUDIO _ LAUNDRY ROOM/MUDROOM F F WDER ROOM �, r I I F, LAUNDRY/MUDROOM ID.102.2 ' j I 123 124 { 26 120 I a i 122 F' I ,—_ BUILDING SECTIONS 104 i a FIRST FI (1(1R I € A 400 - FIRST PI(hR i 101 102 i i G GARAGE LEVEL I , , •- — - - - — _ „ „ GARAGE ... ,, . .,x,.,. .,. . .., .,,.,.. ...,tea _ ,� ,x;. ,. ..,,,. „, ,::...�� . , e�. ��: 3 �a „ GRADE _ - - - _ _ __ _ _- _ - - - - GRADE-- - - - - -- - - - - - - - - - - -- - -- - STAMP &SIGNATURE PROJ. NO.: XXXX moo 8 6 BREDAr�C, DATE: 04/15/2021 A 400 A 400 ��5� SIEFANT�� /A� SCALE: 114" = 1'-0" SHT. NO.: BUILDING SECTION 2X PROPOSED BUILDING SECTION 3X 2 114"= 1'-0" � 1l4" — 1'-0" 160 90 yp Am301 FOF h 2019.00 980 GRETON COURT ----ROOFING ASPHALT -SYNTHETIC UNDERLAYMENT /// - ---ZIP SYSTEM R-SHEATHING(R-3.6) - ------DRAINAGE/VENTILATION SPACE, 10 MIN. ROOF .----STRUCTURAL SHEATHING 24' 10 1/2" ROOFING OVER RIDGE VENT. 1 FILING SET-RIEVA 2021.04.15 METAL FLASHING PLASTIC RIDGE VENT --R-30 COMFORT BATT INSULATION --SYNTHETIC UNDERLAYMENT ROOFING ASPHALT SYNTHETIC UNDERLAYMENT ZIP SYSTEM R-SHEATHING(R 3.6) ZIP SYSTEM R WOOD FASCIA -SHEATHING(R-3,6) -------DRAINAGE/VENTILATION DRAINAGE/VENTILATION SPACE, 1/8"MIN. A- R-15 COMFORT BATT INSULATION ROOF PROPOSAL SPACE, 1/8"MIN. --ENGINEERED WOOD. REFER TO STRUCT. DWG STRUCTURAL SHEATHING STRUCTURAL SHEATHING 23'- 10" R-30 COMFORT BATT INSULATION (2)13/4"X 14 LVL RIDGE BEAM. NEW SHINGLES TO MATCH EXISTING. REFER TO STRUCT, DWG METAL FLASHING R-30 UNFACED FIBERGLASS R-15 COMFORT BATT INSULATION >_< ,-------INSULATION R-15 COMFORT BATT INSULATION FASCIA :> R-23 ROCKWOOL INSULATION R SHEATHING(R-3.6) 2 X 10 ENGINEER WOOD NEW ROOF WEEP HOLE RAINSCREEN 22'-8 1/4" NEW SIDING TO MATCH EXISTING SECOND FLOOR CLG SECOND FLOOR CLG - - - - - - - - - - - 9 19f Oil -011 R-23 ROCKWOOL INSULATION R SHEATHING(R-3.6) -RAINSCREEN NEW SIDING. MATCH EXISTING ROOF EXISTING GARAGE METAL FLASHING ROOF EXISTING GARAGE - - - - - - - - - - - - - 181-211 tz CONSULTANTS STUDIO ---METAL FLASHING 207 ANDERSEN 400 SERIES DOOR AND EXTERIOR SECTION DETAIL-ROOF PEAK AT NEW WINDOW.REFER TO SCHEID. n ADDITION ARCHITECT Q-1, i-1/z v-oi THE TURETT COLLABORATIVE -ANDERSEN 400 SERIES STANDARD EXTENSION 277 BROADWAY, STUDIO 1300 -------ANDERSEN OUTSWING ENTRY DOOR, CREATE AIR BARRIER IN NEW ADDITION -TAPE ALL NEW YORK, NY 10007 102 STRAIGHTLINE, ZIP PANELS WITH ZIP TAPE, SEAL AROUND WINDOWS 212.965,1244 AND ALL OPENINGS WITH CAULK, TAPE, OR AIR SEAL. EXTERIOR SECTION DETAIL-WINDOW HEAD AT DORMER EXTERIOR SECTION DETAIL-DOOR HEAD AND ROOF -NEW STAIR RAILING STUDIO STUDIO _—AVANTECH SUB FLOORING. 207 ANDERSEN OUTSWING ENTRY DOOR, INSTALL AS PER MANUFACTURER SPEC207 1�2,03TRAIGHTLINE }-----20 MIN RATED DOOR 2" T 'AIAT 9 1/ TJI JOIS ER GAP BETWEEN BUILDING AND LANDING —1 - — -- - - - - - —-� >y__ - - - -- - - --- - --NEW WOOD STEP R 23 COMFORT BATT INSULATION SECOND FLOOR SECOND FLOOR 5/8"TYPE X GYPSUM BOARD SHEATHING(R-3,6) /---2X ENGINEERED WOOD —FIBER CEMENT BOARDII , -SUB FLOORING NEW STAIR LANDING JOIST AND DECKING METAL FLASHING jr -.0 R-23 ROCKWOOL INSULATION ---------ANDERSEN SLIDING DOOR. �� + 5/8"TYP X GYPSUM BOARD,TYP.GARAGE R-23 ROCKWOOL INSULATION YOGA STUDIO R SHEATHING(R-3.6) E23 RAINSCREEN NEW SIDING, MATCH EXISTING NEW DOOR BETWEEN GARAGE AND YOGA RM EXT. SECT. DETAIL-WINDOW SILL/HEAD AT 2ND FLOOR EXTERIOR SECTION DETAIL-DOOR SILL AT 2ND FLOOR 'u .011 T_= 1�-0"' Vl_��l/2 GARAGE YOGA STUDIO 5/8"TYP X GYPSUM BOARD,TYP. ----R-23 ROCKWOOL INSULATION123 --WOOD SIDING TO MATCH EXISTING. [U�4 NEW WOOD STEP BEYOND ANDERSEN SLIDING DOOR CEMENT BOARD THE T U R E T T COLLABORATIVE ** -----BASEBOARD,TBID _rt_______TILE WALL. REFERTOFINISH SCHEDULE R-23 ROCKWOOL INSULATION WOOD FLOORING, REFER TO FINISH SCHEID. POWDER ROOM 2 X 8 ENGINEERED WOOD. PACK WITH 8"MINERAL WOOL INSULATION F YOGA STUDIO —PLYWOOD SUB FLOORING 10 MIL VAPOR BARRIER U� - RAINSCREEN RAIN 124 MINERAL WOOL INSULATION 2X ENGINEERED WOOD 10 ---R SHEATHING(R-3.6) MIL VAPOR BARRIER EXISTING CONCRETE SLAB 2X SLEEPERS -ADVANTECH SUBFLOOR I"RIGID INSULATION -WATER GAP BETWEEN BUILDING AND LANDING V RIGID INSULATION -NEW DECK JOIST&WOOD DECK FIRST FLOOR jh FIRST FLOOR jh FIRST FLOOR lt�A(,g 11*4 1 E: liftI`0a'TQPFTTARC" iCOM 01 21. TF- 01 1 NEW DECK JOIST&WOOD 2 01 I DECKING > DRAWING TITLE GARAGE LEVEL GARAGE LEVEL GARAGE LEVEL 14 4-A -6 11-611 11 4 ------LEDGERS BEYOND.ATTACHED TO EXISTING '-A .4 4 41 —EXISTING CONCRETE GARAGE AND HOUSE WALL 4 A, 4' DETAIL WALL SECTIONS 4' SLAB&FOOTING 4 . ------SILL PLATE WITH BOLT ---JOHN MANVILLE R-13 2-IN x 4-FT x 8-FT AP FOIL FACED POLYISOCYANU RATE FOAM INSULATION > -NEW CMU FOUNDATION WALL AND FOOTING. 4'BELOW GRADE --2"BLUE BOARD INSULATION UNDER RAT SLAB I = , , _�i _� i-W �lil j I�= STAMP &SIGNATURE PROD. NO.: xxxx MIL VAPOR BARRIER UNDER 2"RAT SLAB I—I I I__I H=11 ----I I I—I I I__I I I— TAPED TO ALL PERIMETER WALL DATE: 0411512021 ED Ap/1, 01.011 SHT. NO.: L I EI GRADE GRADE GRADE SCALE: 11/2" V-0 -011 3 1 B I F�_l 1_1 El I _1 1 01 EXT. SECT, DETAIL-WINDOW SILL AT 1ST FLOOR EXTERIOR SECTION DETAIL-STEPS AND TERRACE WALL)ETAIL BETWEEN GARAGE AND YOGA STUDIO FOF 16090 Am400 1-011 2019.00 980 GRETON COURT P _ FLAT TAPE AT EXPOSED SLAB/ ��UEIR Y - FLAT TAR AT EXPOSED SLAB/ FLAT TAPE AT EXPOSED SLAB I ' - SUB-FLOOR SUB-FLOOR SUB FLOOR 1 FILING SET-REVA 2021.04.15 1 EXTEND GWB TO UNDERSIDE OF SLAB ACOUSTIC CAULKBOTH SIDES EXTEND GWB T)UNDERSIDE OF SLAB -ACOUSTIC CAULK, BOTH SIDES EXTEND GWB TO UNDERSIDE OF SLAB ACOUSTIC CAULK, BOTH SIDES I, /SUB-FLOOR R SUB-FLOOR/SU I. /SUB-FLOOR i HEAD DETAIL ETAIL H EADD HE AD D DETAIL TAPE&JOINT COMPOUND @ CEILING.SEE RCP FOR TYPE :1, TAPE&JOINT COPPOUND @ CE!ING.SEE RCP FOR TYPE GWB CEILING(TYP.) CEILING. SEE RCP FOR TYPE TAPE&JOINT COMPOUND @ &ELEVATION W &ELEVATION G B CEILING TYF GWB CEILING TYP. ( NATION&ELEVATION ( 1 LAYER OF TYPE(5l8" WALLBOARD BOTHSIDES. SEE — -2 LAYER OF TYPE X 5/8" WALLBOARD BOTH SIDES. SEE SPEC FOR TYPE. 1 LAYER OF TYPE X 5/8" SPEC FOR TYPE. WALLBOAPLAN DETAIL CLAN DETAIL SPECFOR RD BOTH SIDES. SEE PLAN DETAIL a. — -- F r _ — FIBERGLASS INSULATION FIBERGLASS INSUL\TION FIBERGLASS INSULATION WALL BA — BASE AS E AS WALL S PER SCHEDULE PER SCHEDULE WALL BASE AS I' PER SCHEDULE �-ENGINEERED WOOD. REFER TO ENGINEERED WOOD.REFER TO FLOOR PLAN FOR DIMENSIONS 2X2 ENGINEERED WOOD. FLOOR PLAN FOR DIMENSIONS REFER TO FLOOR PLAN FOR FINISH FLOOR DIMENSIONS ,. ACOUSTIC CAULK FINISH H FLOOR . CONSULTANTS ACOUSTIC CAULK ACOUSTIC CAULK REFER TO FIN SIH BOTH SIDES BOTH SIDES B0 - BOTH SIDES . SCHEID DETAIL 1=LR DETAIL(a)FLR I DETAIL a(�FL ARCHITECT THE TURETT COLLABORATIVE �r 277 BROADWAY, STUDIO 1300 NEW YORK, NY 10007 212.965.1244 FBPARTITIONTYPE STUD SIZE OVERALL DIMENSION STC RATING UL DESIGN NO. PARTITION TYPE STUD SIZE OVERALL DIMENSION STC RATING UL DESIGN NO. PARTITION TYPE STUD SIZE OVERALL DIMENSION STC RATING UL DESIGN NO.2 X 4 SEE PLANS B1 SEE PLANS SEE PLANSC1 2x2 SEE PLANS 2 X 6 SEE PLANS B2 SEE PLANS SEE PLANS 2 HR *PROVIDE CEMENT BOARD AT WET AREA.TYP. *PROVIDE CEMENT BOARD AT WET AREA.TYP. PARTITION TYPE A NON-RATED PARTITION TYPE B-2 HR RATED PARTITION TYPE C-NON-RATED POCKET DOOR THE TU P ETT 'COLLABOVATIVE : DRAWING TITLE PARTITION TYPES STAMP &SIGNATURE PROD. NO.: XXXX D A�,c DATE: 04/15/2021 �e5 �STEFq/v 'S SCALE: 3" = 11.0" SHT. NO.: *1609� p�� Am601 FOP Idt"�� 2019.00 980 GRETON COURT DOOR SCHEDULE NUMBER DOOR WIDTH DOOR HEIGHT THICKNESS COMMENTS 777 FIRST FLOOR REV,1 2021.04.15 101 _ 2'-4" T-0" 0'-13/4" 103 y 9'-01, y 7'-0" 104 10'-8" 8'-0" 0'-1 3/4" Anderson Series 400 Sliders SECOND OR 201 2'-10" T-0" 0'-1 3/4" 202 2'-10" T-0" 0'-1 3/4" 203 2'-0" T-0" 0'-11/2" 204 2'-0" 7'-0" 0'-1 1/2" 205 2'-0" T-0" 0'-1 1/2" 206 2'-0" T-0" 0'-1 1/2" 207 2'-8" T-0" 0'-1 3/8" 209 2'-0" T-0" 0'-1 1/2" 210 2'-0" T-0" 0'-11/2" 211 2'-6" T-0" 0'-13/8" 212 2'-10" T-0" 0'-13/8" 213 2'-8" T-0" 0'-11/2" 214 2'-8" 7'-0" 0'-11/2" 215 2'-10" T-0" 0'-13/8" 217 2'-8" T-0" 0'-1318" 219 3'-0" T-0" 0'-1314" 274 2'-0" 5'-10" 0'-1318" WINDOW SCHEDULE NUMBER MODEL HEIGHT WIDTH��— COMMENTS SECOND FLOOR CONSULTANTS r 201 ANDERSEN-400 SERIES 4'-6" 4" 202 ANDERSEN-400 SERIES 4'-6" 2'-8" _ 203 ANDERSEN-400 SERIES 4'-6" 2'-8" ARCHITECT 204 ANDERSEN-400 SERIES 4'-6" 2'-8" THE TURETT COLLABORATIVE 205 ANDERSEN-400 SERIES 4'-6" 2'-8" 277 BROADWAY, STUDIO 1300 206 ANDERSEN-400 SERIES 4'-6" _ _ N EW YORK, NY 10007 207 ANDERSEN-400 SERIES 4'-6" 3'-0" 212.965.1244 208 ANDERSEN-400 SERIES 4'-6" -4" 213 ANDERSEN-400 SERIES 2'-01/8"' 2'-8" 214 ANDERSEN-400 SERIES 2'-01/8" 2'-8" _ 215 ANDERSEN-400 SERIES 2'-01/8" 2'-8" 216 ANDERSEN-400 SERIES 2'-01/8" 2'-8" THE ' URETT COLLABORATIVE DRAWING TITLE DOOR AND WINDOW SCHEDULE STAMP &SIGNATURE PROD. NO.: xxxx D ABC DATE: 04/15/2021 SCALE: SHT. NO.: 00 tree 16090 ©� AwA FOP NON 2019.00 980 GRETON COURT UEIREr=N­---,,����IA71 1 FILING SET-REV.1 2021.04.15 5'-8" 2-10 114" 101-81, 2'-1 7/8" -/--- — 00, V.1.F. V.I.F. V.I.F. V.I.F. 4 x 4 PRESSURE TREATED LUMBER COLUMN ON CONCRETE FOOTING WITH WOOD (11 X)2 x 10 PRESSURE TREATED NAILING BLOCK(TYP.) LUMBER SKIRT BOARD CONSULTANTS (lX)2 x 10 PRESSURE TREATED LUMBER SKIRT BOARD 2'-9"SEGMENT EACH END CONTINUOUS 2X6 SHEAR WALL W/15/32" ARCHITECT (2X)2 x 8 PRESSURE TREATED JOIST uj PLYWOOD STRUTURAL PANEL BOTH SIDES OF WALL, USE W/8d -9S NAILS W/3"EDGE SPACING EACH STUD, USE SIMPSON HDU2-SD2,5 THE TURETT COLLABORATIVE 277 BROADWAY, STUDIO 1300 ui o HOLD DOWN W1 HILTI HAS THREADED ROD ANCHOR, USE HILTI n- �o HIT-HY 200A EPDXY W/6"EMBEDMENT ON ANCHORS,TYP. BOTH NEW YORK, NY 10007 co w SIDES OF WALL.X, 212.965.1244 - — - — - — - — - — - — - LLJ C) (f) Q'- LU �- cr-- ::D cD < 0 "'- (D b ui z w o o Lo Q� U) 1-u CL w (D cxo j-u Of Lu < ;�� Lu 0 Z w c'j uj u- m 0 � ::D fV U) (3)2X6 WD. POST W/BLOCKING @ MID SPAN EACH FLOOR,TYP.(3)PLACES �,,� LL: CD cl) PROVIDE NEW 16"D X 3'-6"W X 42" DEEP PAD FOR SUPPORT OF RISERS THE TURETT COLLABORATIVE : 2)'t M*nApway �lfjojo lZoo I Nfw Y00g' mv i0ool T� 2tZ.46?i iZAA I F: 5'-113/8" 1/81, oe DRAWING TITLE 22'-0 1/2" V.I.F. FRAMING PLANS FIRST FLOOR FRAMING STRUCTURAL PLAN-FIRST FLOOR FRAMING V-0" STAMP&SIGNATURE PROJ. NO.: xxxx D ARC, DATE: 04/1512021 sCEFAN SCALE: 1/4" = 1 1.011 SHT. NO.: 16090 ®l 01 OF N 2019.00 950 GRETON COURT WEIR EV Sly 1 FILING SET—REV.1 2021.04.15 5'8" 16-8 1/8" I � I € I � II CONSULTANTS 3 3 2 X 12 LEDGER. LAG TO EXISTING TOP PLATES WITH 3/8"X 6"LAG i I SCREWS @ 12"O.C.WITH OVERSIZED WASHERS, USE SIMPSON IUS 2.37/9.5 HANGER FOR TJI JOISTS. ARCHITECT 2'-9"SEGMENT EACH END CONTINUOUS 2X6 SHEAR WALL W/15132" I PLYWOOD STRUTURAL PANEL BOTH SIDES OF WALL, USE W/8d THE TURETT COLLABORATIVE NAILS W/3"EDGE SPACING EACH STUD, USE SIMPSON HDU2-SD2.5 277 BROADWAY STUDIO HOLD DOWN W/HILTI HAS-E THREADED ROD ANCHOR, USE HILTI HIT-HY 200A EPDXY W/6"EMBEDMENT ON ANCHORS,TYP. BOTH i NEW YORK, NY 10007 SIDES of WALL. 212.965.1244 i' 2 X 6 @ 12"O.C.WALL W/BLOCKING @ MID-SPAN NEW 2X6 @ 24"O.C.SHEAR WALL W/15/32"PLYWOOD SHEATHING ONE SIDES, USE 8d NAILS W/4"EDGE SPACING EACH STUD, HOLD 3 DOWN WALL W/3/8"DIA. HILTI KWIK HUS-EZ SCREW ANCHORS @ O.C., EMBED ANCHORS 21/8"INTO EX.CONC. SLAB. `s i € € �I 4-- - - - - - -- - --- �- (2X)2 x 8 HEADER ; (3)2X6 WD. POST WI BLOCKING @MID I _ SPAN EACH FLOOR,TYP.(3)PLACES zt / 9 1/2"DEEP,230 SERIES TJI @ 16" O.C. I / —-- —(2X)2 x 8 HEADER j / I . I - I I / (2)2 X 6 @ 16"O.C.WALL W/BLOCKING @ MID-SPAN I � i i I o I i okr':&d'wa y $wvbo i�bk € R�t3� �ra�toa NY i*Ot"7 "22'-0 112 I r - - - -- - - - --- --- 1/2" DRAWING TITLE i FRAMING PLANS - SECOND FLOOR FRAMING } STAMP &SIGNATURE PROD. NO.: XXXX D q,�)C' DATE: 04/15/2021 �STEFAfV "/�� SCALE: 1/4" = 1'-0" SHT. NO.: n STRUCTURAL PLAN-SECOND FLOOR FRAMING U 1/I V--0" sq��il 02 s090 yp '" of N 2019.00 980 GRETON COURT �SSUVREVIS 1 FILING SET-REVA 2021.04.15 1 16'-4 1/2" CONSULTANTS 2'-9"SEGMENT EACH END CONTINUOUS 2X6 SHEAR WALL W/15/32" ARCHITECT PLYWOOD STRUTURAL PANEL BOTH SIDES OF WALL, USE W/8d NAILS W/3"EDGE SPACING EACH STUD, USE SIMPSON HDU2-SD2.5 THE TURETT COLLABORATIVE HOLD DOWN W/HILTI HAS-E THREADED ROD ANCHOR,USE HILTI 277 BROADWAY, STUDIO 1300 HIT HY 200A EPDXY W/6"EMBEDMENT ON ANCHORS,TYP. BOTH NEW YORK, NY 10007 SIDES OF WALL. 212.965.1244 i I I 2 X 6 @ 12"O.C.WALL WI BLOCKING @ MID-SPAN I I I I u I M C�l I !#1 l 1 •I I / � I (3)2X6 WD. POST W/BLOCKING @ MID SPAN EACH FLOOR,TYP. (3)PLACES /—RIGDE BEAM ABOVE =t I 1. c I ! cl, / I I I I I I i I I I 2 x 8 AT 16" I I ' 0 C. I I: I: / d r I I' (2)2 X 6 @ 16"O.C.WALL W/BLOCKING @ MID-SPAN I I I THE TURETT COLLABORATIVE ** I I I I I I I I I I ! I / i 'I !, :ss'e �� ;����Y ��l'z�As�S t�dt5 3 ���• Ys�aae• �tv 14�v�� 22'-01/2" DRAWING TITLE n FRAMING PLAN-ATTIC U 114" FRAMING PLANS - ATTIC STAMP&SIGNATURE PROJ. NO.: XXXX D q�c DATE: 04/15/2021 �sfF. N rSi SCALE: 114" = 11.0" SHT. NO.: 16)90 �0�� ®1 03 Foy NEB 2019.00 980 GRETON COURT SSUE1RE�V Sl 1 FILING SET-REVA 2021.04.15 11'-8" jj-------------- - --- - ( 6 POST W/BLOCKING @ MID- SPAN (3)2 X 12 WD.TRIMMER W/(2) 10.5"X 1/4" THICK A36 STEEL FLITCH PLATE, SEE DETAIL p (TYP. BOTH TRIM THIS SIDE OF ROOF) N O O 2 z @) o w u F- xw cV m ty (4)2"X 12" D.F. NO.2 OR BETTER o � CONSULTANTS o u.. R O � U ARCHITECT N o i �- i / N CoI, THE TURETT COLLABORATIVE o W (3)2X6 WD. POST W/BLOCKING @ MID 277 BROADWAY, STUDIO 1300 / -- -- - - - '— �—-- - Xw„/ — SPAN EACH FLOOR,TYP. (3)PLACES NEW YORK, NY 10007 N m 212.965.1244 CANTILEVER 1 (2)1 314"X 14 LVL RIDGE BEAM I' II II O L? N O tr O `co uj 0 Z F~- � LLI b o W 0 O li N m O @l j (3)2-X 12 D.F. NO. 2 OR BETTER - i U / ' II NO o (3)2 X 12 WD.TRIMMER W/(2)10.5"X 114" THICK A36 STEEL FLITCH PLATE, SEE DETAIL / `i (TYP.BOTH TRIM THIS SIDE OF ROOF) � w CD / (2X)2 x 8 HEAL__R1 x m__ (3)2 x 6 POST W/BLOCKING @ MID- / i I SPAN ' I 10'-6" FRAMING PLAN-ROOF THE ° URETT COLLABORATIVE : 2"x 12" LVL RIDGE 2"x 10"AT 16" BOARD SPACING (2)10.5"X 1/4"THICK A36 FLITCH PLATE axc�atrsc, � c� w ra, r i (3)2 X 12 D.F.JOIST, SEE PLAN _ STAGGERED 3/4"DIA.A325 DRAWING TITLE STEEL STRUCTURAL THROUGf- BOLTS @ 16" O.C. (2)11 718" LVL � FRAMING PLANS - ROOF NV \ 3"x 12" LSSUH310 BY SIMPSON --STRONG T!E(TYPICAL ALL 3"X12" 2'-0"MAX. \\\-2"x8"AT 16"O.C. RAFTERS) STAMP &SIGNATURE PROJ. NO .: XXXX 2 FRAMING DETAIL#1 C3) FRAMING DETAILS#2 4 FLITCH PLATE BEAM DETAIL ¢ED A�' DATE: 04/15/2021 �StEFANTG�'y SCALE: As indicated SHT. NO.: 1609CJ p@smi 05 FoF NON /