Loading...
HomeMy WebLinkAbout50541-Z . t � TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50541 Date: 4/11/2024 Permission is hereby granted to: Parmeter, Brian 340 Second St Apt A Macon GA 31201 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 705 Smith Dr S, Southold SCTM # 473889 Sec/Block/Lot# 76.-2-28 Pursuant to application dated 3/6/2024 and approved by the Building Inspector, To expire on 10/11/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector -76 TOWN OF 50UTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 w Telephone (631) 765-1802 Fax(631) 765-9502 hl s.11www.southoldtoy nn . ov Date Received APPLICATION For Office Use Only PERMIT NO. '5-v4J4—q Building Inspector: Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an " �" Owner's Authorization form(Page 2)shall be completed. pw Date:3-4-24 OWNER(S)OF PROPERTY: Name:BRIAN PARMETER SCTM# 1000-076-00-02-00-028-000 ProjectAddress:705 SMITH DR S, SOUTHOLD, NY 11971 Phone#:631-830-9865 1Email:parmbb@gmail.com Mailing Address:705 Smith Dr S, Southold, NY, 11971 CONTACT PERSON: Name:Michele Cardon Mailing Address 177 Cantiague Rock Road, Westbury Phone#:516-318-4035 Email:lipermits@sunrun.com DESIGN PROFESSIONAL INFORMATION: Name:Manouchehr Hakhamaneshi Mailing Address:1708 Roxborough Road, Charlotte, NY 28211 Phone#:980-689-9776 Email:info@mightyengineeringco.com CONTRACTOR INFORMATION: Name:Sunrun Installation Mailing Address:177 Cantiague Rock Road, Westbury, NY 11590 Phone#:516-318-4035 Email:lipermits@sunrun.com DESCRIPTION OF PROPOSED CON TRUCTION [--]New Structure ❑Addition MrAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other 29,550.00 Will the lot be re-graded? ❑Yes VKio Will excess fill be removed from premises? ❑Yes NAO 1 PROPERTY INFORMATION Existing use of property: (J � Intended use of property: Zone or use district in which premises is sit ated: Are there any covenaWO d restrictions wait respect to this property? ❑Yes IF YES, PROVIDE A COPY. 8 Check t Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):M ichele Cardon MAuthorized Agent ❑Owner Signature of Applicant: ) LAC-�--L� �' Date: 3-4-24 STATE OF NEW YORK) SS. COUNTY OF Michele Cardon being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Iday of 1►•r 20 1 1 uw N ary Public DAVID J MACKEY Notary Public, State of New York Reg. No. 01I MA6381235 -AUTHORIZATION Qualified in Naa®au County (Where the applicant is not the owner) Commission Expires October 01,2026 Brian Parmeter residing at705 Smith Drive do hereby authorize Ive (e, 6,4, to apply on my behalf 4 e Town of Southold Building Department for approval as described herein. 3-1 -24 Owner's Signature Date Brian Parmeter Print Owner's Name 2 SUNRINC-02 TWAN CERTIFICATE OF LIABILITY INSURANCE DATE(MM DDNYY`) 9111223 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements, PRODUCER CONTACT r Tanner Ndllma.... Tann.. FnX cense# Alliant Insurance Services,Inc. 560 Mission St 6th FOC36861 PHONE No,E Waite .. ..___. mm C.No) .......... San Francisco,CA 94105 nt.com. Walter"Tanner alila IN SURER(S,],AFFORDINGCOVERAGE ,,,, _NAIC# .... �NsuFzg6,n_Evanston Insurance Company _ ...... ........ 35378. .. INSURED lNSl1RE,R.,B Zi rich American Insurance Company_. mmmmm,,,mmmmm 16535, Sunrun Installation Services,Inc sul:E(,.CAmerican Zurich„Insurance Company 40142 ^_ 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURERD: San Luis Obispo,CA 93401 WSURER E -.__..._. _. ..._.... INSURER F COVERAGES rERTIFICATE NUIaABER: REVISION NUMBER. THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, REDUCED.LIMITS SHOWN MAY HAVE BEEN BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDLSUB LIMITS EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LTR INSD POLICY NUMBER R ... ���.� POLICY POLICYWEXP A X COMMERCIAL GENERAL LIABILITY RENTED 1,000,000,EACH„OCCURRENCE 2,000,000 DAMAGE�O ..... _ b�IIWAGET !t'0.4h5tRi .. .� .m� CLAIMS-MADE X OCCUR MKLV5ENV104332 10/1I2023 7011/2024 5,000 PERSONAL&ADV INJURY 2,000,000 ' _ .... .... 2,000,000 GE PGGREGAATELIMIT'APPJJESP R REGA 2,000,000OX DPE& OC PRODUC PAGG OTHER:Retention.$200,000 Per Project Agg 5,000,000I COMBINED SINGLE LIMIT 2,000,000 B AUTOMOBILE LIABILITY X... ANYAUTO BAP614287702 1011/2023 10/1/2024 90DILY,INJURY or arson �.. _...... OWNED SCHEDULED AUTOS ONLYU AUTOS BODILY INJURY(Per accident _$.,.,„..... IF",�S ONLY c Na p pried Liability D d.: $..... 1 _..0... X fgW66 ,000,000 CCURRENOE �,..UMBRELLA LIAB �__JOCCUR EXCESS LIAB CLAIMS-MADE gG....rCREGATE DED RETENTION$ C WORKERS COMPENSATION X ST.11,TI.1T,1 � H�.. ___ AANY PROPRIETOR/PARTNER/EXECUTIVE NH)EXCLUDED? Y N�ry N/A WC614287602 10/1/2023 10/1/2024 L NCH ACCIDENT �;���i�� AND EMPLOYERS'LIABILITY .i IN ( E L GISF�S) EA EMPLOYEI ......�_... . If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Addltlonal Remarks Schedule,maybe attached If more space Is required) Workers'Compensation Policy WC1614287601 Deductible:$1,000,000. Evidence of insurance CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Route 25 Southold,NY 11971 AUTHORIZED REPRESENTATIVE e�� 0--� ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD v NEWWorkers' CERTIFICATE OF STATIC Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 225 Bush Street Suite 1400 1c.NYS Unemployment Insurance Employer Registration Number of San Francisco,CA 94104 Insured 50-86426 4 Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e., 1 d.Federal Employer Identification Number of Insured or Social Security a Wrap-Up Policy) Number 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage(Entity 3a.Name of Insurance Carrier Being Listed as the Certificate Holder) AMERICAN ZURICH INSURANCE COMPANY Town of Southold Town Hall Annex Building 3b.Policy Number of Entity Listed in Box"1 a" 54375 Route 25 P.O.Box 1179 WC 6142876-02 Southold,NY 11971 3c.Policy effective period 10/01/2023 to 10/01/2024 3d.The Proprietor,Partners or Executive Officers are ❑ included.(Only check box if all partners/officers included) � J� all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perqury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Mark AN (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 71_te_ 14&1 10-01-2023 (Signature) (Date) Title: VP/Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (415)946-7500 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov oVT� Compensation workers' CERTIFICATE OF INSURANCE COVERAGE TY# Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART L.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. 202 Commerce Dr., Ste. 7 Moorestown, NJ 08057 1 c.Federal Employer Identification Number of Insured Work Location of Insured(Only required ifcoverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 77-0471 407 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) The Prudential Insurance Company of America Town of Southold 53095 Route 25 3b.Policy Number of Entity Listed in Box 1a Southold, NY 11971 CG-52830-NY 3c.Policy Effective Period 1/1/2024 To 12131/202 4. Policy provides the following benefits: A.Both disability and Paid Family Leave benefits. ❑ B.Disability benefits only. ❑ C. Paid Family Leave benefits only. 5. Policy covers: X A.All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as described above. a.k Date Signed January 02, 2024 By (Signature of insurance carrier's authorized representative or NYS licensed insurance agent of that insurance carrier) Telephone Number 215-658-7318 Name and Title Carolynn Smith - VP Contracts IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans AccepWrice,Unit,.PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box 4B,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB_120.1 (12_21) 111 IIIPiimiiiiiiiiiiiiiiiiiii�iiuiiuiiiuiiiillllIII Suffolk Cotmty mpt Of t Affair., 1,jj� lvW NIln4l pfi± R M L HtWkwss Name 1"(4"1 ffi"ll l% sug fun llviqgmbvn Selmo., deenso NMW)Om' No Rull,,,w Marjo w-mad: 09/23W)14 e. asac r!xpfros: ogio W024 Suffolk County Dept of 0011) Labor, Licensing 8, Consurner Affairs Ao I M ASTER ELECTRICAL LICENSE T7�I Name SAMY moUNAS Business Name SUNRUN INSTALLATION SERVICES eio fies jti�aw ii�ie INC. SO"10IL01"ItAllf) 3878 Alolk License Number ME-3 Issued 10/01/2003 f;>ro-30- Expires: 10,0112025 � a MIGHTY ENGINEERING.CO. .February 8,2024 RE: . ... CERTIFICATION LETTER Project Address: .:BRIAN PARMETER RESIDENCE 705 SMITH DR S SOUTHOLD:NY, 11971 Design Criteria: . ... -Applicable Codes=2020 NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and 2018 NDS -Risk Category=11 -Wind Sp'eed'=128 mph,Exposure Category.B,Partially/Fully Enclosed,Method Ground Snow Load=25 psf. . -ROOF AR-01:2 x 8 @ ITOC,Roof DL=8 psf,;Roof L L/SL=19 psf(Non-RV),Roof LUSL=12.9 psf,(PV) To Whom It May Concern, = A structural evaluation of loading was conducted for the above address based on the design criteria listed above.- Existing roof structural framing has been reviewed for additional loading due to installation of.PV-Solar System on the roof.The structural review applies to.the sections of roof that is directly supporting the solar PV system. Based on this evaluation, I:certify that the alteration to the existing structure by installation.of the PV system:meets.the prescriptive compliance requirements of the applicable,existing.building and/or.new building provisions adopted/referenced above. . ... . . Additionally,the PV module assembly.including attachment hardware has been reviewed to be in accordance.with the manufacturer's. .. .. . .. . .. .. . specifications and to meet:and/orexceed the requirements set forth by the referenced codes. 64 Sincerely; rN , P� ,;IDigitdysigned by Mafi&ichehr r` Hakhamaneshi 0 09 05'00 .. 39B Date:-202 OFESSION 05:36:57:- Mighty Engineering C6.1 1708 Roxborough:RdCharlotte,NC 28211 1 (980)689.9776 1 info@mightyengineeringco.com pg 1 of 4 SHEETINDEX LEGEND SCOPE OF WORK m GENERAL NOTES . . .. . . . .. . PAGE# DESCRIPTION SYSTEM SIZE:5670W DC,3840W AC •ALL WORK SHALL COMPLY WITH 2O2D NEW YORK STATE RESIDENTIAL CODE SE SERVICE ENTRANCE": ' PV-1.0 COVER SHEET ® •MODULES:(14)HANWHA p-CELLS:Q.P.EAI<DUO BLK .. WITH 2O18 IRC/IBC/IEBC,.MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS ' - ML-G10+405 AND INSTALLATION INSTRUCTIONS. w. PV-2:0 _ SITE PLAN INVERTERS:.(1)DELTA ELECTRONICS:E4-TL-US MP MAIN PANEL .RACKING:TOPSPEED,ATTACHMENT DETAIL,MOUNT TO •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-10 LAYOUT WOOD DECK:SNR-DC-00004 PV-4.0 ELECTRICAL RAPID SHUTDOWN:(14)APSMART RSD-S-PLC ROOFTOP •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. SP SUB-PANEL..: MODULE LEVEL RAPID SHUTDOWN DEVICE. `�-�F NEW.. PV-5:0 SIGNAGE Rl: �<Q'a�NR HA Q� PHOTOVOLTAIC'SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER. * A MODULESCONFORM;TO AND ARE LISTED UNDER UL:61730. _ i s � SM SUNRUN METER INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. RACKING. MST LISTED L 270 � 103982 3. w. PM DEDICATED PV METER WITH R TYPE If.•SNAPNRACK RACKING SYSTEMS,IN COMBINATION TH TYPE I;0 fESS10 ODUL LASS AFIRE RATED. INV INVERTER(S) Dlg'ltally Signed � DAL AC RSA ARRAY BOUNDARIES 90.1 MBnouchehr.' •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS'AN L CONDUCTORS RE WITHIN AY BOUNDA S PER NEC 6 2(1). b,/,' AC DISCONNECT(S) .' w. :.. . C TION F TOP CONDUIT 690• ONSTRUC FOREMAN LACE CON RUN PER 31(G). DC DCDISCONNECT(S) ARRAY DC CONDUCTORS ARESIZED.FORDERATEDCURRENT. NakhamaneShl 0 Date:'2024.02:09 ll.i7AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX 05;3 7:17 05'00' •13.96 AMPS DERATED SHORT CIRCUIT CURRENT 1690.8(A)&690.8(B)]. ABBREVIATIONS F-7 INTERIOR,EQUIPMENT A - AMPERE : L:J SHOWN AS DASHED .. _ AC 'ALTERNATING CURRENT; .. .. •. .. •.. -. .. . AFC ARC FAULT CIRCUIT INTERUPTER ® CHIMNEY - .. .• .. .. .. sung n .. AZIM AZIMUTH. _ .. COMP COMPOSITION m DC DIRECTCURRENT ,, Q _ATTIC VENT - 00825-ME . .. .. Er EXISTING : FLUSH ATTIC VENT' VICINITY MAP. O _ _, ,. _ 1]I GIMNGUEROCKROAD,N'ESTBIIRY NY 11590� ESS ENEROYSTORAGESYSTEM -O. . PVC PIPE VENT FAXB�38B 3N2 EXT EXTERIOR :. - METAL-PIPE VENT - - - .... ... ... �-- RESIDENCE:CUSTOMER RESIDEN MIT. . :.INTERIOR : :. .- - BRIAN PARMETER . MSP. .. MAIN SERVICE PANEL CM T-VENT 705 SMITH DR S,SOUTHOLD, 11971 (N) 'New .. ... ..: .. ... NY, �.: SATELLITE DISH - -y NIS NOTTOSCALE .• .. /^ _ • — E (631)830-9865 FIRE SETBACKS oc ON CENTER �� .. APN:1000-076-00-02-0O-028-000 ® PRE-FAB PREFABRICATED : - - PROJECT NUMB ' t ..: PSF PourlDs PER sougRE Fool � -,• •• - � ��- � �• •--•� � �- � � � �� �� � � � �- � 216R-705PARMER �'HARDSCAPE ay. PHOTOVOLTAIC .: .: .: 4" .: .. .. ESIGNER: (415)5B0-0920 ex3 D RSD.:.''RAPmsNUOONMDEVICE —PL' PROPERTY LINE ry. JOHN.PAULTECSON'. SOLAR MODULES TL - TkANSFORMERLESS SCALE:NTS SHEET TYP irPlcaL : REV NAME DATE COMMENTS OVER SHEET v VOLTS i C. w warns REV:A3 2/8/2024 ... LAN LANDSCAPE .... - ... �'.: .. . �9 PAGE POR PORTRAIT :_ -TOPSPEED MOUNT: - - - PV 1 0 am eto rerslan 4.095 _. _ . SITE PLAN-:SCALE=1/18"=1'-0" SE 0 INV LM J ' SITE PLAN DETAIL-SCALE=3N28"=1'-0" . ® .:. FIRE SETBACKS PATHWAYS,.. ROOF.PAT ' (18...Ty (3 - .TYP) . ROOF PATHWAYS o (N)ARRAY AR-01 (E)DECK (g TYP) p�. (E)DRIVEWAY OF NEW y (E)SKYLIGHT (E)SKYLIGHT' �®o E RESIDENCEq. OAR�F .. sunrun.. 5.. 0082ME .- C 1n CRNfl4GllE ROCXR 580' RIOId=BOS.SW.50B! E SHED . F0.CE6388.P12' - NOTES: CUSTOMER RESIDENCE:' •'RESIDENCE DOES NOT CONTAIN"ACTIVE FIRE BRIAN.PARMETER SPRINKLERS: (E)FENCE 705 SMITH DR S SOUTHOLD, . NY 1197 ARRAY DETAILS: • TOTAL ROOF SURFACE AREA:3000 SQFT. (631)830 8865 .. .. .. .- • TOTAL PV ARRAY AREA:295.9 SQ FT. o. APN:1000-076-00702-00-028-000- • PERCENTAGE PV COVERAGE: PROJECT NUMBER: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE 216R-705PARM AREA)!100=9.9% ..: .. ... .. .. .. - .. .. .. .. .. w DESIGNER: (415)580-6920 ex3 .... ARRAY TRUE MAG PV AREA JOHN.PAUL TECSOM. PITCH AZIM AZIM I (SQFT) AR=01 1 30° -117 129° - '295.9 SITE PLAN REV:A3 2/8/2024 NOTE:ROOFTOP MODULE LEVEL RAPID-SHUTDOWN DEVICE E INSTALLED ON EACH MODULE PER NEC:690.12. PV 2:0 . - - .. Tem(Yete_Verslan 4.O.B5 s. s. ROOF INFO FRAMING INFO q. s ATTACHMENT INFORMATION DESIGN CRITERIA:. Max 'OC Minimum Number of Mounts per Up-Slope Max Landscape -Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span 'Spacing Detail' Edge(Landscape/Portrait) Overhang' Overhang' SNOW LOAD:25 PSF WIND SPEED: COMP SHINGLE- TOPSPEED;ATTACHMENT DETAIL,MOUNT AR-01 1-Story. 2X8RAFTERS. 15'-1" 16" .. . . 1 -6 0'-.10" TOPSPEED' TO WOOD DECK:SNR-DC-3.0004 S.S.LAG SCREW128 MPH 3-SEC UST D1=AR-01-SCALE:3116"=1'-0" WASHER WOOD SCREWS FULLY AZIM:117° PITCH:30° G THROUGH.. WOOD PENETRATING GH DECK . -T-7„ .' 37'-4a' _3-4_ .. . q. .. .. .. .' 1'-11" f t HA,yyq o ry I T-11" a (E)SKYLIGHT � s J'�`� 103982 R SSIsunrun . ONP� .. '4 12'S" .. 0062 - . - - tncwrucus Rock Bono.wesreutrr,t+rttsao ROY2' CUSTOMER RESIDENCE: BRIAN PARMETER INSTALLERS SHALL NOTIFY ENGINEER OF ANY 705 SMITH DR S,SOUTHOLD, Y POTENTIAL STRUCTURAL ISSUES OBSERVED: N ' 11971 PRIOR.TO PROCEEDING W1 INSTALLATION. TEL.(631)630-9865 MOUNT NUMBER FOR LEADING DOWNSLOPE'EDGE "' "'" SHALL:MATCH REQUIREMENTS LISTED ABOVE INSTALLs. -� � � APN:1000-076-00-02-00-028-000' PER.TOPSPEEDM INSTALLATION MANUAL. PROJECT NUMBER: .., CONTRACTOR MAY SUBSTITUTE SNAPNRACK 216R-705PARM DECKTRACK MOUNTS(SNR DETAIL SNR-DC-00453)WITH A MAX OVERHANG OF 6" DESIGNER: (415)580.6920 eX3 ....... IF A MODULE(EXCLUDING SKIRT)IS WITHIN 12"OF A PAULTECSON ROOF EAVE,RIDGE,OR GABLE END,AN ADDITIONAL SHEET TOPSPEED.ATTACHMENT MUST BE USED ON THE LAYOUT MODULE EDGE WITHIN THE 12"ZONE. REV:A3 2/8/2024 L am afe wlsfoa a 0.95 .. . . .. . 120/240 VAC SINGLE PHASE SERVICE..' METER#: NOTE:TOTAL PV BACKFEED=20A OPSEGLI 98366280. USED FOR INTERCONNECTION CALCULATIONS ' ACCOUNT#: UTILITY 9632948302 GRID . 11 EXISTING 150A .. . i, �1t bwy�ip (` MAIN BREAKER �yt. F l . DISCONNECT . LOAD SIDE TAP .. .. .. .. .. p'��FESSIONP� . 3 (N)LOCKABLE Dlgltaliy signed 1 EXISTING 150A BLADE TYPE- . .. - ( MAIN BREAKER FUSED AC DELTA ELECTRONICS: by Nestor ` E4-TL-US t .. DISCONNECT:. 3840 WATT INVERTER JUNCTION Box :.pV MODULES HOUg"htOn .3 .. 2. OR EQUIVALENT 1. HANWHA Q-CELLS:Q.PEAK DUO BLK EXISTING ✓. G10+405 .~' 150A MAIN. .� + i,//, (14)MODULES Date: 2024.02.09 PANEL (Y FACILITY - ✓..•".' - (1)STRING OF(7)MODULES 05_:38:07 -05'001 2 OA FUSES (1)STRING OF(7)MODULES LOADS FRCLLAID SQUARE D, _ LOAD RATED DC _GRWND D221NRB DISCONNECT WITH AFCI, LEVEL L RAPID HU S-PLC MODULE LEVEL RAPID SHUTDOWN DEVICES. . 3R,30A. APSMART.TRANSMITTER. 1201240VAC' CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL.' GROUND, 5-M 0082 E 1 . NONE: (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER " � t))CPMIAGVE ROCK RORD,KEBIBURY NY 1159D . PHDf.�005.540,SOD) 2 :v PVC OR EQUN. (4)1O:AWG THHNrTHWN-2, NONE (1)10 AWG THHN/THWN-2: 3 V PVC OR EQUN:. (2)10 AWG THHN/THWN-2. (1)10 AWG THHN/THWN-2 _ (1)8 AWG THHN/THWN-2. CUSTOMER RESIDENCE:. BRIAN PARMETER OR. ., 705 SMITH S,SOUTHOLD, NY,"11971 MODULE CHARACTERISTICS HANWHA Q-CELLS:Q.PEAK DUO BLK TEL.(631)830-9865" ''ML-G1 O+405: -.. .. 405 W '', : - - """ APN:1000-076-00-02=00-028-000'.. OPEN CIRCUIT VOLTAGE: 45.34 V MAX POWER VOLTAGE: 37.39 V PROJECT NUMBER: SHORT CIRCUIT CURRENT: 11.17 A 216R-705PARM . . SYSTEM CHARACTERISTICS-INVERTER 1. . DESIGNER: (415)580-092 x3 SYSTEM SIZE: 5670 W J PAULTECSON SYSTEM OPEN CIRCUIT VOLTAGE: 353.38 V • SHEET. ' SYSTEM OPERATING VOLTAGE: 261.73 V MAX ALLOWABLE DC VOLTAGE: 480 V ELECTRICAL' SYSTEM OPERATING CURRENT: 21.66 A SYSTEM SHORT CIRCUIT'CURRENT: '27.93 A REV:A3.: 2/8/2024 . empate_rors�an a.o e p. I INVERTER t :. . NOTES AND SPECIFICATIONS: !lci `� SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLEPHOTOVOLTAIC SYSTEMPHOTOVOLTAIC • DISCONNECT 110.21(B),;UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,ORCK HAZARD .. IF REQUESTED BY THE LOCAL AHJ. . COMBINER PANEL MAXIMUM SYSTEM VOLTAGE: qgp 1 •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVENE AND LOAD DO NOT ADD LOADS _ WORDS,COLORS AND SYMBOLS. 2793 '1 •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING;.LABEL NERGIZED IN RENT OF THE CHARGE .METHOD AND SHALL;NOT BE HAND WRITTENOSI110N �•TED OUTPUT � LABEL SHALL BE OF SUFFICIENT DURASIUTY TO WITHSTAND THE ENVIRONMENTPHOTOVOLTAIC AC COMBINER QF :APPUCABLEj. • •• ••1 • 1 • 1 N/A •1 'INVOLVED. ." .. .. .. -LABEL LOCATION:.': '': 'PER CODE(S):CEC 2019:705.12(B)(2)(3)(c), .•SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011;PRODUCT SAFETY": ; ' -' '' SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. ' AC COMBINER PANEL NEC 2017:705.12(B)(2)(3)(e). LABEL LOCATION: .. .DO NOT COVER EXISTING MANUFACTURER LABELS; -' AC COMBINER PANEL OF APPLICABLE). �- � - -��� - �INVERTER(S),DC DISCONNECT(S). : � - ��� � � -- PER CCDE(S):CEC 2019:69D.13(B),NEC : : PER CODE(S):NEC 2617:690.53 - - 2017:690.13(B) ' 7AN UALPOWERSUPP.LYSOURCE OUTPUTCONNECLION URCES:UTILITY GRID,NOT RELOCATE THIS :. D PV SOLAR ELECTRIC OVERCURRENTDEVICE SYSTEM P�sLOF NEW yO LABEL LOCATION: .. LABELLOCATION HO(/C ADJACENT TO PV BREAKER(IF .. DUTY SERVICE METER AND MAIN APPLICABLE). - SERVICEPANEL PER CODE(S):CEC 2019: PER CODE(S):CEC 2D79:705.12(B)(3),NEC .... 201T.705.12(0)(3) . 705.12(3)(2)(3)(b),NEC 2017:," _ " .. 705.12(B)(2)(3)(b). ..". :. .. .. • 108135 FORSOLAR • op'�OFESSIONP�� . LABELLOCATION: a - INSTALLED WITHIN 3'OF RAPID SHUT DOWN: �+ p SWITCH PER CODE(S):CEC 2019:690.56(C)(3),NEC _ BUILDING SUPPLIED BY UTILITY' ": ..: ... 2017:690.56(C)(3),IFC 2012:605.11.1.IFC 2018: "" ... ... 1204.5.3,CFC 2019:1204.5.3.: sunrun. GRI D AND PHOTOVOLTAIC. :' SYSTEM �w//qq pp �+�/ •�C ® C GM ENIUMP PG� .. 00825-ME .. .. ■ ■ : ■r■ J�'�D• UT0"W i .. .. .. .. .. FA%�965.29µBG. 2 FO RV.NYtt FO N'E61BU 580" ■• • CUSTOMER RESIDENCE: :. BRIAN PARMETER LABEL LOCATION: .. 705 SMITH DR S,SOUTHOLD, INTERIOR AND EXTERIOR DC CONDUIT EVERY 1 O FT, , 3„ NY,1�971 AT EACH TURN,ABOVE AND BELOW PENETRATIONS, TURN RAPID SHUTDOWN.: .. .. .. .. .. ' ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS.. SWITCH TO THE"OFF' �" TEL(631 830-9865 PER CODE(S):CEC 2019:690.31(G)(3),690.31(G)(4);. ) .. NEC 2017:690.31(G)(3),690.31(G)(4)IFC 2012: ''.. "POSITION TO SHUT DOWN '_ ''.. ".. .. .. APN:1000-076-00702-00-028-000' 605.11.1.4 ': PV SYSTEM AND REDUCE ' SHOCK HAZARD IN THE PROJECT NUMBER' . ..' MR-705PARM ARRAY. 'DISCONNECT OPERATINGPHOTOVOLTAIC AC DISCONNECT MAXIMUMAC CURRENT: .: .: .. .. .. OB DESIGNER: (415)5eo fig ICJ LABEL LOCATION: JOHN.PAULTECSON . NOMINAL OPERATING VOLTAGE: 1 VAC POINT OF INTFRCONNECTION .. .. .. .. R COD 5372 " LABEL LOCATION:. :. :. .. LABEL LOCATION: - (PE E:NEC690.58(B),NEC705.10,22. 30.2(E)); SHEET. AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 F.T)FROM THE SERVICE SIGNAGE INTERCONNECTION," DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):CEC 2019[090.54,NEC 2017:600.54 : ARE CONNECTED. '' 'w ''' - PER CODE(S):CEC 2019:690.56(C)(1)(0),NEC 2017: REV:A3 " 2/8/2024 .. .690.56(C)(1)(0) : .. P�GE powered by . Seen �.'4tJ7r ' dffra�t�•. ®cars TOP BRAND PU " 'S Orieatjr TONoO .. 2019 �J, Q.ANTUM-TECHNOLOGY: F Higher yield per sur(acA;aiea,lower BOS costs higher power classes,and an efficiency rate of up to 19.9%. O - wdh excel) ' INNOVATIVE'ALL WEATH HN. L' y. Optimal yields;whatever the weather ent ` low-light and temperature.behaviour. V„Y ENDURING HIGH PERFORMANCE Long,term geld security with Anti LID Technology,Antl PID .Technology',Hot-Spot:Ptotect and Traceable Quality.Tra.QT"'. ... ... EXTREME WEATHER RATING + _ High=tech alurnWum alloy frame,certdie'd for high snow(5400 Pa)and wind loads(4000 Pa). " A RELIABLE INVESTMENT Inclusive 12-yearproduct warranty and 25-yeas linear perforrtianuewarranty=. STATE OF THE ART.MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell:separation and innovative-wiring with.Q.ANTUM Technology..• . APT test condition's according to IEC/TS 62804-1:20:'L,method B(-1500V,168h) "See data sheet on rear for further information. TkE.IDEAL SOLUTION FOR:. .. ... 'Rooftopairayson Rooftop arrays on .. . residential buildings commercial and . ... 'industrial bui dings .. .. .. . ... . ... .. Engineered in Germany, MECHANICAL SPECIFICATION -ormat -66 3 in x 39.4 in x 1-26in(including frame) (1685mM x 1000mm x 32mrn) A4 �liaight'... 41. Ibs(1 kg)':".. ... Front Cover .0.13in(3.2mm)thermally pre-stressed glass with en0-r llectlonte e technology '••v�, Beck Cover Composite film i Frame Black anodized aluminum _ Cell 6 x 20 monocrystslline Q:ANTUM solar half cells ,' 'v,• Junction Box 2;09-3.981n x 1.26-2.361n x 0:59-0.71iri O .60mm x 15-18mm).iP67,with bypass uw-El Cable, 4mm2 Solar cable;(+)z43,3'in(1100mm),(+t;3.3in(1100mm), ++ y Connector Stsubli MC4,Hanwhe-Q CELLS HQC4,Amphenol UTX, ,� + Renhe 05-6.Tongling TL Cable01S,JMTHY JM601;IP68 or lra tlrmm�: oera.oaw Ilemq Friends PV2e;IP67 {�" ,II To w s°.4 . _ oaes•u+s. : .:. ELECTRICAL CHARACTERISTICS . q. POW ER CLAsS : 315 34a 326' 330 MINIMUM PERFORMANCE AT STANDARD TEST:CONDITIONS,STCI(POWER TOLERANCE+5 W/-OW) . Power at MPPi' P,,°, (WI 315 820' 325: 330 Short Circuit Current' Is, [Aj: .:• 9.99 10.04 10.10 10:15 E... ... 'Open Circuit Voltage' VOC (V)"- 39.84 : 40.10 40.36 40.62- C t MPP I� ._ Current a •.• . [Al[AJ '. 9.51 9.5E 9.61. 9.67 c V 33:14: .Voltage at MPP. V,,,° 'IV] .33.47 33.81 34.14 E(ficiencyl rl (%} z18.7 >-19.0 :19.3 a19.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOTs: Power at MPP.'": 'P,,,, (WJ 235:9' 239:6 243.4 :' 2471 • 7 Short Circuit Current. Isn". (Al 8.05. 8A9 ". 8.14 8,18 E Open Circuit Voltage Va (VI 3Z56 37.81 3&06 38.31 c ..Current at MPP 1. {AJ,: Z48 ... Z52 •Zt 7 7%.. Voltaga at MPP V1A0° _ _ IV) ' 31.53 31.85 32.17 32.48 "' : 'Measurement toleranc,tsPvot3 .,l. ;Vat5%atSTC'1000W/m2;25z2'C,AM1.5accbidingto.lEC60904-3.2800W/m2,'NMOT,speetrumAM1.5 Q CELLS PERFORMANCE WARRANTY " PERFORMANCE AT LOW IRRADIANCE. ... At least 98%ofnommal power during first year.Thereafter Max.0.54% r. s g �� f degradation per year, 31 At lees!9 % 4 boo L__ __- W of nominal' power up !p o0years At pleas85%dominalweruPto .. ' 425years. - .. .. S ' All dalawithin measurement tolerant- - a eo .• a.Full warranties in accordance with ioo +oo eoo l000 ' lha warranty terms of the Q CELLS' ' 0 1 sales organisation of your re eel ve .. . , o N I p i'. ..�; .r; country. : ... .. ... . vEens Typical Module performance under low irradiance crr,dalcns In 4 comparison to STC conditions(25°C,SOOOW/m?) rn TEMPERATURE COEFFICIENTS e a' _ ( %rJ - O.04: epeatue Coefficient ofV -0.27Temperature Coefficient of 1s - n TernporatureCoefficientofP,rpv,:. Y I%/rT -0.35 Normal Module Operating Temperature NMOT (°Fj 109t5.4(43t3°C) 6 PROPERTIES FOR'SYSTEM DESIGN r.taximum System Voltage V,; [VJ lobo(IEC)/1000(UL): Saiaiy Class II p M ,iiir,um,$oriesFuseRating (ADC) '20 Fire Rating bakedonANSI'/UL1703 - C(IEC)/TYPE,2(UL) : Max-DeslgnLoad,Push/Pull' (Ib's/ft2j. 75(3600Pe)/55'(2667Pa} Permitted ModuleTAmperature 40°Fupto+185'F' u:C Max.Test Load,PushJ Pull" fibs/ft2J 113(540OPa)/84(4000Pa) ' on.Continuous Duty (740°Cup.t6+85°C) See Instal!ation Manual gg ...QUALIFICATIONS.. CERTIFICATES PACKAGING INFORMATION x UL.7d1.VDE OuafdyTested.CE-compliant,IEC 61215:2016,IECtil730:20Ah, Number:of Modulas per Pallet 32 _s- "pp<ca'a n Class 14 U.S.Patent No.9,893,215(solar taus)... $.:. . Numbde6f Pallets per 53'Trailer." Number of Pallets pec40'H 26 C-COhtainer Pallet Dimensions(LxWx,H) 69.3x;•15.3% 8.gin(1760x1150x1190.mm).. 4 w:.,. Pallet Weight, . . � 1415I,bs(642kg) Note.Installation instructions must be followed.Seethe installation and operating manual or contact'our technical service department for further information on approved installation and use of this product., ' Han%vha O CELLS Aturlas laic. 400 Spectrum Cent er.Drive,.Sulle:1400.Irvine,CA 92618:USA I TI'L:+1 949 748 59 06112 M.1 t c-rnqufay@us-q-cells-com l W48 www.q•ceUs.us Solar Inverter for North America hELT�I Single Phase Solar Inverter for North America M4-.TL-US I M5-TL-US:l M6-TL-US.1 M8-TL-US I M10-TL-U8. A� e. Key Features: • :.Smart inverter with:BLE, optional:WiFi; Ethernet, 3G/4G cellular communication • Support.bird irectional.cioud communication •. Support remote'diagnosis and OTA. • ype. -pro ec ion : Built-in AFCI &.Rapid shutdown controller • CEC efficiency 97.5% - . .Option: Revenue.Grade Meter:ANSI 12:20 (0.5% accuracy) • . UL 1741 SA, HECO-& CA Rule.21 compliant . ... . ... . eAELTA .:Solar Inverter for North America SPECIFICATIONS Model M44L-U6 MS-TL-US M6-TL-US M8-TL-US' • 111110-TL-US Maximum system:voltage 600 V 'Nominal voltage "380 V•. Maximum operating voltage Voc"" 540•V Operating MPPT range 50 V to 480 V" .... Maximum input current(per MPPT) 12 A. .. 12 A 12 A. 12 A. .. 20 A " Maximum short circuit current @ STC 15 A/15 A :. ::15 A/15 A 15 A"/15 A:/.15 A 15 A/15 A/15 A :: 25 A/25 A Maximum DC/AC.ratio 1.3 DC disconnect Integrated :- - MPP tracker 2 2 ..31 3 2 Input strings available ' " ' 2:2.. 2_2. .. 2=2.2 ' .. ..2.-2=2 2.2.. Nominal power @ 240V 3840 W 4800 W 5760 W." 7680 W: : 9600 W Maximum output power" 4000 W. 5000 W 6000 W 8000 W 10000 W 183 Vac to 228 Vac . . @ 208 Vac" •; • o age range 211 Vac to 264 Vac 240 Vac .'Maximum continuous current-'' : . 16 A: .': PO A :24 A 32 A. 40 A Nominal frequency 60 Hi Frequency range 59.3 Hz to 60.5 Hz ...: _. Adjustable frequency range .• 50.Hz to 66 Hz Night"consumption THD @nominal power :• : "" " <3% " Power factor @ nominal power >0.99 Adjustable power factor range.: . : .... .0.85i to 085c Maximum"efficiency" " " .. 98% CEC efficiency 97.0%@ 208 V ".97..5 0%@ 208 V 97.D 0%;@ 208 V 97.5%@ 208 V .:97.5%@ 208 V 97.5 /o@240V" ""97.5 /o@240V 97.5•/o@240V 97.5 /0@240.V" :97.5 /o@240V . "" -22 T to 149°F(-30°C.to 65.° Operating'temperature range C) :". ' de-rating above 113°F(45°C) Storage temperature range "• -40°F to 185 T(-40'C to 85°C) Humidity- 0%'to 95%. Maximum operating altitude 9,843 ft(3,000 Acoustic noise <45 dB(A);@:3•ft(1 m) Rev 12A—06/2019 ©dopyright 2019 Delta Electronics(Americas),Ltd.All rights reserved. Specffications subject to change without prior notice.. I. N AWELTAI .:Solar nverter for North America SPECIFICATIONS Model M4-TL-US. MS-TL-US M6-TL-US MS-TL-US: .' M10-TL-US Dimensio6s(W x H z D) :16,7.9 23.2 x 5.9 in(425 x 590 z 150 mm) Weight 1) 41.9 Ibs(19.0,kg) .41,9 Ibs(19.0 kg) 44,3"Ibs.(20.1 kg) 45:2 Ibs(20,5,kg).I 47.6-Ibs(21.6 kg) .. . "Cooling "'" Natural convection Natural convection with internal fan DC connection : Spring contact type . Admissible-conductor size DC " AWG 12 to AWG 8 " AWG 10 to AWG 8 AC connection Spring,contact type " . Admissible conductor size AG" AWG 10 to AWG 6 .. .. AWG 8 to AWG 6 Communication:interface BLE,optional WiFi,Ethernet,313/4G cellular communication Enclosure material Die-casting aluminum Enclosure.protection.rating Type 4 Safety UL1741,CSA-C22.2 No.107.1-01 "Software approval UL'1998' Ground fault protection UL1741 CkD.'.': ." Anti-islanding protection IEEE 1547,IEEE 1547.1 EMC. " FCC part 15 Class B .... AFCI .. .. UL 1699B.(Type 1),NEC 201.7•Artide,690.11 Integrated meter:; .ANSI C12.20(meets 0.5%accuracy) Grid support regulation UL_1741 SA,California Rule2l:phase 1,2(pending),HECO Compliant ...: Standard warranty 10 years R 1) Without communication meter Delta Electronics (Americas),.Ltd.. :. 461.01 Fremont Blvd;Fremont;.CA 94538 Sales Email:Inverter.Sales'Cdeltaww.com Support Email:.Inverter.Support@deltaww.com Sales Hotline;+1=877-440-5851 or+1-626-369-8021 Support Hotlin.e:+1-877-442-4832 Support(Intl.):f1-626-369-8019 Monday to Friday from 6am:to 6pm PST(apart from Holidays) www.Delta-Americas.com &ELTA kev 12A—0612019 O Copyright 2019 Delta Electronics(Americas),Ltd.All rights reserved. Specifications subject to change Without prior notice.. s � - MJ6 _ r� System designed with y g All parts fit in a box for easy maximum versatility for any `� logistics arrays including staggered " Drop-in features make the install process intuitive and fast Simple design allows system to be installed by single installer Listed to UL Standard 2703 for on the roof Grounding/Bonding and Fire Classification SnapNrack highestis designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the • of :.: Flash :Track with Patented Umbreli:a' Technology; Single Umbrella.lag,screw secures flashing and flash track to roof in one complete action • Umbr:ella technology.provides weatherproofing with a. long= lasting mechanicalseal Flash track i s.:d esigned .for..m aximum versatility with 6 incfi.es_of North-South adjustability for all Mounts o.unts :. Single mount used as all locations dh' array Extreme timesaver by:eliminating link interference throughjhei flexibility of the Mount to change orientation , Features a rock-:in:channel nut d6s'ign:for easy attachment to Flash.-Track Slotted.rise r.provides leveling for easy height adjustments Lin s : . . .... ... •..Simple design provides mounting; platform between two to.fo.ur.. . . . ...:modules ...: • Clamps:o:nto top of modules securing them in place while:.providing -: .•1� row-to-:row bonding .:Next row of:modules easily slides-into place:as.:with the Mou:nts.: .; :Skirt . • Easily locks to bottom of module mounts and links for clean aesthetics .. Ensures a strong structure for leveling and.alignment of first row of modules Skirt length is compatible with:both portrait and. landscape module orientations Quality. Innovative . Superior. i SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources • improve overall installationquality and . • www.snapnrack.com contact@snapnrack.com 2019 .•Nrac:k Solar MountingSolutions, DESCRIPTION: " .. SNAPNRACK, RL UNIVERSAL, MOUNT' mwatkins .:.REVISION: 501a1' W10d111t111g SO Ufi011 S: '.PART NUMBER(S)::. :.. .: .... .. .. 5 5MAR 9410 ._. .. .. ) 0-0 242-02155 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 5 USA PHONE(415 59 900 FAX(415)SBD�6902 THE INFORMATON IN THIS DRAW NO IS CONFIDENTIAI.AND PROPRIETARY.ANY REPRODUCTION,%YRIMSURE,OR USE THEREOF IS PROHIBITED Yr11HOUT THE q. WRITTEN CONSENT OF SUNRUN SOUIH LLC. ' . .. ...... .. . .... .. ...... .... .. ...... .. ...... .. .. 10. .. .. .. 4 9.. 8 1. 2 . o 6 PARTS,LIST ITEM QTY :, DESCRIPTION ..:.. 1 - 1 SNAPNRACK; RL UNIVERSAL;-RISER, MILL '2 1 SNAPNRACK,:RL UNIVERSAL;:LEVELER, MILL. 3 1-:: SNAPNRACK, RL:UNIVERSAL, MOUNT:BOTTOM, MILL 4.. . ...1 SNAPNRACK,.RL UNIVERSAL, MOUNT TOP, BLACK _ . : 5 . 1 SNAPNRACK, .RL UNIVERSAL;.BONDING CLIP:' ::. 6 1: SNAPNRACK, DROP IN/ROCK IN CHANNEL:NUT . . . .. . 7 1 - BOLT,. FLANGE, 5/161N. 18 X 3/4IN, CLEAR, SS 8 : 1 BOLT, FLANGE,:SERRATED, 5/161N-18 X 1IN SS 9 1:". SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1: " BOLT,*FLANGE, SERRATED, 3/8IN-1:6 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN.THREAD, BLACK, SS MATERIALS: : 6000 SERIES ALUMINUM, STAIN LESS OPTIONS: q. DESIGN LOAD (LBS):. .... 623 UP, 67.4..DOWN, 505 SIDE... ULTIMATE LOAD (LBS):: N/A TORQUE SPECIFICATION::::: - 12 LB-FT CERTIFICATION; UL 2703,'FILE E359313 "•"' WEIGHT (LBS): :. 0.73:. . .. ...... . . . .. ...... DESCRIPTION: DRAWN BY: S.NAPNRACK, RL.UNIVERSAL,.MOUNT mwatkins SIR C��Q . EVISION: SOIaC Mounting Solutions. R . PART NUMBER(S)::.. . -� - -• �� 595 MARK 9410', ET STREET,29TH FLOOR.SAN FRANCISCO,CA 5 USA .. .. PHONE 415 59 900.�FAX(415)580-6902 242-02155 _.. .. r :THE INFORMATION IN THIS DRA'MNG IS CONRDENTIALAND PROPRIETARY,ANY REPRODUCTION.DIRITTE N ORUSETHEREOF IS PROHIBITEDIMTHOUT TIE ,. .. .. NRITTEN CONS ENT OF SUNRUN SOUTH UC. w. 1.50 w. w. 3.41 ... .... FSW . . . .. .. .. .. ... .. - .. 1..:50 . . 2.35 a. -1.50 1.55 .66 2.00 � 1.24 S. c . :: . - 1 SLOT 2.63 1:50 . . .. ...... .. -;ALL DIMENSIONS--IN INCHES -7 Co AMEjYDM ENT SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE t DESCRIPTION SE SERVICE ENTRANCE •SYSTEM SIZE:567OW DC,384OW AC •ALL WORK SHALL COMPLY WITH 2O20 NEW YORK STATE RESIDENTIAL CODE PV-1.0 COVER SHEET MODULES:(14)HANWHA Q.CELLS.Q.PEAK DUO BILK WITH 20181RCNBCOEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS ML-G10*405 AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN INVERTERS;(1)DELTA ELECTRONICS:E4.TL-US PVa.O LAYOUT MP MAIN PANEL RACKING:TOPSPEED,ATTACHMENT DETAIL,MOUNT TO •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. WOOD DECK:SNRDC30004 PV-4.0 ELECTRICAL •RAPID SHUTDOWN:(14)APSMART RSD.S-PLC ROOFTOP •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. SP SUB-PANEL MODULE LEVEL RAPID SHUTDOWN DEVICE PV-6.0 SIGNAGE PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY LC PV LOAD CENTER GROUNDED IN THE INVERTER SYSTEM COMPLIES WITH 690.35 MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. SM SUNRUN METER INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741- PM DEDICATED PV METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2103. •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE 1,OR TYPE II MODULES,ARE CLASS A FIRE RATED. OF NE INV INVERTER(S) N,14�r�•n •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL J��< AC- AC DISCONNECT(S) CONDUCTORS ARE WTHIN ARRAY BOUNDARIES PER NEC 690.12(1). N •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). x DC n DC DISCONNECT(S) ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT- 103982 11.17 AMPS MODULE SHORT CIRCUIT CURRENT. f F$$10Na CB IQ COMBINER BOX •13.96 AMPS DERATED SHORT CIRCUIT CURRENT 1690.8(A)&690.8(B)). ABBREVIATIONS INTERIOR EQUIPMENT A A14PM L J SHOWN AS DASHED AG ALTERP ATM CURRENT AFC ARC FAULT WCUT NTE R VTER ® CHIMNEY s u n r U ALM AnWJTR COUP CouvamcN RG UWECTCURRERT ATTIC VENT 00825-ME Io on 0 FLUSH ATTIC VENT VICINITY MAP Ess ENEFtW770RACESnTEll o PVC PIPE VENT n+uc ms�oA•n Ezr ampim' ® METAL PIPE VENT Tr CUSTOMER RESIDENCE r MSP �LAV U-RV"PANEL OD T-VENT r 7705 SMITH OR S,E SOUTHOLD. SATELLITE DISH :_ _ ' NY,11971 km NOT To We E ; TEL(631)830.9865 GG C"CENTM FIRE SETBACKS fJ - APN:1000-07&W02-00 2MW r�Er� F , E l�l� PROJECTNUMBER: T5F FCUms PER$MAREFOOT ° .� HARDSCAPE - �- t� � 216R-705PARM w P"um ov; / - DESIGNER: (415)580 8920 ex3 RSC R SHUFO OEVE'E —PL— PROPERTYLINE `• J/j� !'�Jy SOLAR MODULES ? J, ( JOHN PAUL TECSON n rwwsToaucwF.ss SCALE:NTS , r'� ,/ ��. SHEET Tw REV NAME DATE COMMENTS COVER SKEET v vaTs K wArrs rj. ti B P.MCAUGHLIN 41312023 LTILITY NUMBER r,F j!,i -"�. REV:B1 4125J2024 LAN Lmosc E �•,' L�r j B1 A.GULLEN 4125/24 LAYOUY PM PWTRrt PTOP AEED MOUNT PAGE PV-1.O SITE PLAN•SCALE 1116" 1'4' BE Q INV MPSITE PLAIT DETAIL_ SCALE 3112V 1'-W 0 FIRE SETBACKS ROOF PATHWAYS (IWTYP) (3 TYP) ROOF PATHWAYS o (N)ARRAY AR-01 (E)DECK (3'TYP) `R (E)GATE (E)DRIVEWAY OF Nflyy O 4 cj1JaENR NAK0 (E)SKYLIGHT ` '• ' a` x (E)SKYLIGHT - 4%" 0 4 103982 o (E)RESIDENCE ° A�FES51�Na� O - ' s� sun run 0 (E)> - 00625-ME SHED , NOTES: y CUSTOMER RESIDENCE: RESIDENCE DOES NOT CONTAIN ACTIVE FIRE BRIAN PARMETER SPRINKLERS- (E)FENCE 705 SMITH DR S.SOUTHOLD. NY.11971 ARRAY DETAILS: TOTAL ROOF SURFACE AREA:30M SOFT. TEL.(631)830-9885 • TOTAL PV ARRAY AREA.M.9 SO FT. APN:I000-078-00-024"28-0D9 • PERCENTAGE PV COVERAGE: PROJECT NUMBER: (TOTAL PV ARRAY AREAITOTAL ROOF SURFACE 216R-705PARM AREA)-100=9-9% DESIGNER: (415)5W69206w3 ARRAY TRUE I MAG I PV AREA JOHN PITCH AZIM AZIM (SOFT) PAULTECSON AR-01 30' 117' 129' 295.9 SHEET SITE PLAN REV:Bt 4/25/2024 NOTE:ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED ON EACH MODULE PER NEC 690.12 PAGE PV-2.0 rrm�e w.e,-�aas ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Minimum Number of Mounts per Up-S" Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF eta Span Spacing Edge(Landscepe/Portratt) Overhang Overhang SNOW LOAD:25 PSF WIND SPEED: COMP SHINGLE- TOPSPEED.ATTACHMENT DETAIL,MOUNT 128 MPH 3-SEC GUST. AR-01 TOPSPEED 1�0� 2X10 RAFTERS 15'-1' 10' TO WOOD DECK:SNR-DC-30004 1 D-10' S.S.LAG SCREW (4)p14 X 2.25'SS SEALING A •Z1M:11711T* SCALE:3118'=1'-0" WASHER WOOD SCREWS FULLY PITCH:30' PENETRATING THROUGH WOOD ...,, ..-,,,,�. .. DECK } 14' 24'•4' —4 } .tt(jv NFfyr �tS�EHB HA < N (E)SKYLIGHT 1 103982 e�?V A'PoFfSS10NP� sunrun 14' 2V-4'— 00825-ME CUSTOMER RESIDENCE: BRIAN PARMETER INSTALLERS SHALL NOTIFY ENGINEER OF ANY 7D5 SMITH DR S,SOUTHOLD, POTENTIAL STRUCTURAL ISSUES OBSERVED NY,11971 PRIOR TO PROCEEDING Wf INSTALLATION. MOUNT NUMBER FOR LEADING DOWNSLOPE EDGE TEL(631)830-SW5 SHALL MATCH REQUIREMENTS LISTED ABOVE INSTALL APN:1000-078-06-02-00.0284100 PER TOPSPEED"-INSTALLATION MANUAL- PROJECT NUMBER: CONTRACTOR MAY SUBSTITUTE SNAPNRACK 210R•705PARM DECKTRACK MOUNTS(SNR DETAIL SNR-DC-00453)WITH A MAX OVERHANG OF 8' DESIGNER: (415)580.0920 mi3 IF A MODULE(EXCLUDING SKIRT)IS WITHIN 12-OF A JOHN PAUL TECSON ROOF EAVE.RIDGE,OR GABLE END,AN ADDITIONAL SHEET TOPSPEED ATTACHMENT MUST BE USED ON THE LAYOUT MODULE EDGE WITHIN THE 12'ZONE. REV:B1 4/25/2024 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER#: NOTE:TOTAL PV BACKFEED=20A PSEGLI 98366280 USED FOR INTERCONNECTION CALCULATIONS UTILITY ACCOUNT R: GRID 9632948303 1 EXISTING 150A MAIN BREAKER i DISCONNECT LOAD SIDE TAP 3 ��OF NEwr (N)LOCKABLE >�+ O NaKy' EXISTING 150A BLADE TYPE yt a�pR �¢ MAIN BREAKER FUSED AC DELTA ELECTRONICS: * ono t DISCONNECT E4-TL-US N I 3840 WATT INVERTER JUNCTION BOX PV MODULES cr_ 3 2 OR EQUIVALENT 1 HANWHA Q-CELLS:Q.PEAK DUO BLK n DAEXISTMAW s ING ��� + // ML-G10+405 � ,e� 103982 i^� PANEL _ / (14)MODULES(1)STRING OF(7)MODULES •U�p � FACILITY 20A FUSES �' (1)STRING OF(7)MODULES 'PoFESSIONP LOADS SQUARED LOAD RATED DC (14y APSMART RSD-S-PLC MODULE D221NRB DISCONNECT WITH AFCI, LEVEL RAPID SHUTDOWN DEVICES 3R,30A APSMART TRANSMITTER 12D1240VAC sunrun CONDUIT SCHEDULE B CONDUIT CONDUCTOR NEUTRAL GROUND 00825-ME 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER +n wneu�roawwn,rrtam+R+.m nseo nae.�aovn 2 1'PVC OR EOU IV. (4)10 AWG THHN(THWN.2 NONE (1)10 AWG THHN/THWN-2 3 1'PVC OR EQU IV. (2)10AWG THHNrrHWN.2 (1)10 AWG THHNrrHWN.2 (1)6 AWG THHNtrHWN-2 CUSTOMER RESIDENCE: BRIAN PARMETER 705 SMITH DR S,SOUTHOLD, NY.11971 MODULE CHARACTERISTICS HA14WHA O-CELLS:O.PEAK DUO BLK TEL(631)830-9885 ML-G10+405: 40S W APN;1000-07040-02-00-0284)00 OPEN CIRCUIT VOLTAGE: 45.34 V MAX POWER VOLTAGE: 37.39 V PROJECT NUMBER: SHORT CIRCUIT CURRENT: 11.17 A 216R-705PARM SYSTEM CHARACTERISTICS-INVERTERI DESIGNER: (416)5805920ex3 SYSTEM SIZE: 5670 W JOHN PAUL TECSON SYSTEM OPEN CIRCUIT VOLTAGE: 353.38 V SYSTEM OPERATING VOLTAGE: 261.73 V SHEET MAX ALLOWABLE OC VOLTAGE: 480 V ELECTRICAL SYSTEM OPERATING CURRENT: 21.66 A SYSTEM SHORT CIRCUIT CURRENT: 27.93 A REV:81 4/2512024 PAGE PV-4.0 I�WA'R•�--KING WARNING "" "`ER' NOTES AND SPECIFICATIONS: • • . ,LTAIC , DISCONNECT • •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE PH ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM 110.21(8).UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTXIN 690,0R COMBINER PANEL IF REQUESTED BY THE LOCALAHJ. VOLTAGE460 ! •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD 00 NOT ADD LOADS 27.93 WOWS.COLORS AND SYMBOLS.MAXIMUM CIRCUIT CURRENT • SIDES MAY BE ENERGIZED IN •LABELS SWILL BE PERMANENTLY AFFUIEO TO THE EQUPMENT OR WIRING TFEOPEN PASR10N LABEL LOCATION: 1• • METHOO AND SHALL NOT BE WIND WRITTEN. PHOTOVOLTAIC AC COMBINER(IF •LABEL SHALL BE OF SUFFICIENT DURABILITY TO Yl1THSTAND THE ENVIRONMENT A CODICA LE).CEC 2018 ••DC-TO-DC • ! ••NIA •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z536.4.2011,PRODUCT SAFETY LABEL LOCATION: PERER CODE(Sy: :705.12(B)(2)(3)(c), CONTROLLERSIGNSANDLASELS UNLESS OTHERWISESPEGFIED. INVERTER(8),ACIOC OISCONNECF(SL NEC 20M 705.12(Bx2x3xe) LABEL_LOCATKIN: AC COMBINER PANEL(IF APPLICABLE). UIVERTER(S),OC DISCONNECT(S). •00 NOT COVER EXI,STW G MANUFACTURER LABELS. PER CODE(Sk CEC 2010:690.13(B),NEC PER CODE(S):NEC 2017:690,53 2017:M.13(8) I WARNING + WARNIN'G DUAL POWER SUPPLY POWER SOURCECUIPUTCONNECTION SOURCES:UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: NEW,, 1 ADJACENT TO PV SREAMR(IF UTftm SERVICE METER AND MAIN �.`(Oor Nt•W yp SERVICE PANEL PER CODE(S):CEC 2019: PER CODE(S):CEC 2019:705.12(BX3).NEC 705,1248)(2x3)(b),NEC 2017: 2017:705.72(B$J) .�4 (•,1 705.124Bx2)(3)(N) 00 a i CJ FOR • Lw PV SYSTEM 103982 LABEL LOCATION: AA�FESSION�� wST °WE(YC aUT°CSwm�PER ODSCE22o00.66tX33 NEC BUILDING SUPPLIED BY UTILITY 12045.3.CFC 019-.1C4.5.3 e05.11.1,IFc 2018: GRID AND PHOTOVOLTAIC ,2015.3.L:FC 2D,7,204.5.3 s u n ru n SYSTEM 4• SOLAR PV SYSTEM EQUIPPED 00825-ME w - • • • L WITH RAPID SHUTDOWN M6C106•gfMi - � CUSTOMER RESIDENCE: Io 11RIAN PARMETER LABEL LOCATION: 705 SMITH DR S,SOUTHOLD, INTERIOR AND EXTERIOR DC CONDUFr EVERY 10 FT, NY,11971 AT EACH TURN,ABOVE AND BELOW PENETRATION$, '� TURN RAPID SHUTDOWN ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. SWITCH TO THE ., ww T'EL(631)83Q9885 PER CDOE(S).CEC 2019:690.31(G)(3),M,31(Gx4), �SHUT DOWN NEC 201?.690.31(Gx3).690.31(Gx4)IFC 2012: APN:1000-076-00-02-00-026.OW 60SALIA PV SYSTEM AND REDUCE PROJECT NUMBER: SHOCK HAZARD INTHE PV SYSTEM 216R-70SPARM PHOTOVOLTAIC AC DISCONNr:CT ARRAY. DISCONNECT MAXI.M.UM AC•• DESIGNER: (415)WO-692004l •. VOLTAGEERATINGAC LABEL LOCATiDN: JOHN PAUL TECSON NOMINALPOINT OF INTERCONNECTION LABEL LOCATION: LABEL LOCATION. (PER CODE:NEC690-WBI.NEC706.10.2MA7,230.2(E)) SHEET AC DISCONNECT(S).PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT I M(3 FT)FROM THE SERVICE SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):CEC 2019:W90.54,NEC 2017:69D.54 ARE CONNECTED. PER CODE(S):CEC 20%690.56(C)(1 xa).NEC 2017: REV:B1 4125/2024 69o'SNC)(1x6) PAGE PV-5.0 u•mlw_wsos..a u