HomeMy WebLinkAbout50514-Z ozi.
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 50514 Date: 4/4/2024
Permission is hereby granted to:
MontgomeEy, James
89 Manor Ln
James port, NY 11947
To: construct single-family dwelling as applied for per SCHD approval.
At premises located at:
2820 Stanley Rd, Mattituck
SCTM # 473889
Sec/Block/Lot# 106.-8-58
Pursuant to application dated 2/27/2024 and approved by the Building Inspector.
To expire on 10/412025.
Fees:
SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $3,621.50
CO-NEW DWELLING $100.00
Total: $3,721.50
Building Inspector
y:�yyEk �pp�
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 litt :Hww",,Sou lioldtownii gov
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only
d
PERMIT NO. w� _ — Buildinglnspector. ��� � ��
Applications and forms must be filled out in their entirety. Incomplete
applications will not be accepted. Where the Applicant is not the owner,an
Owner's Authorization form(Page 2)shall be completed.
Date:February 23, 2024
OWNER(S)OF PROPERTY:
Name:Brooklyn Timber LLC scTM # 1000-106.00-08.00-058.000
Project Address:2820 Stanley Road, Mattituck NY, 11952
Phone#:917-626-2996 1 Email:monumentalproperty@yahoo.com
Mailing Address:3080 Route 112 Suite B, Medford NY, 11763
CONTACT PERSON:
Name:Christopher F. Dwyer
Mailing Address:437 South Country Road, Brookhaven, NY 11719
Phone#:631-286-8668 Email:cdwyer@lkma.com
DESIGN PROFESSIONAL INFORMATION:
Name:Robert A. Steele, P.E., Executive Vice President, L.K. McLean Associates, P.C.
Mailing Address:437 South Country Road, Brookhaven, NY 11719
Phone#:631-286-8668 Email:rsteele@lkma.com
CONTRACTOR INFORMATION:
Name:Oasis at Mattituck Corp.
Mailing Address:3080 Route 112, Suite C, Medford, NY 11763
Phone#:631-767-4807 1Email:peter@modernagehomebuilding.com
DESCRIPTION OF PROPOSED CONSTRUCTION
*New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
❑Other $
Will the lot be re-graded? WYes ONO Will excess fill be removed from premises? *Yes El No
1
PROPERTY INFORMATION
Existing use of property:vaCant Intended use of property:Single Family Residence
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
AC this property? RYes ONO IF YES, PROVIDE A COPY.
l9 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name):Christopher F. Dwyer ®'Authorized Agent ❑Owner
Signature of Applicant: ,° Date:
STATE OF NEW YORK)
SS:
COUNTY OF Suffolk
Christopher F. Dwyer being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the Agent
(Contractor,Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
Z3"l day of Ee—�L-V--. , 20 Z� ��
Notary Public
CHRISTINE L. 13ELSON
NOTARY PUBLIC, State of New York
No,01SE5W7003 Ro Ill;11 ICE t JT1 [ Il „Fill ,
flUafIfled In Suffolk Counter �
COIL MIrwWn Expires October 27,202.- (Where the applicant is not the owner)
,r 4 L residing at ,,...�
�! Dwyer (�K Christopher F. MUl +)
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
f Bh
PROJE "
O CT
' `s LOCA917N
/ / a• r
——Tc-— LOC TIQN ASAP
N.T.S.
2 �/ t , - _ / O rRwnv a�au rJNivaD 24 am�ogmwcc
I I � RM+OIIB
1 2 STY.4 BEDM.
£ � r�� •+t-
RESIDENCE ##€
UAT.W/ M �
B E
FF.=T0.3 �aaataoero
Tmm-0fe.00
wnmm(
rq r - D 1
II d � musc z wr
_. GARAGE
1 F.F.=BL9i 5 T ua BBaRe s€Nts _
w 41n1¢
— IlM�01 moxE .. �R 5>�a••� -..�91i ��fftti�fit.
r�Tm Tom. )
� � a
1
1 b k t 1 �€ uz�cx.c- - aria
W j
D IT—
SUFF MI COUNTY
AP DEPROVAR OF C N NIALTH SERVICES
PERMIT FOR APPROVAL®F OONSTRUCTION FOR A
� IT
r �a�1 I '- - i^°� ;fs s I SINGLE FAMILY RESIDENCE ONLY
DATE Imam H-s-
saop s 44$ A AsPR 0
'04' FOB AXIIA T x
L$m '
_ x€ Rs E� YEARS i aA�
(AFRL
J
fN II
IGINS E"P
(1:0ECfEB DROII WATER FNCOIINfEANDWATER ED)
V N O EL 040'\ TEST HOLE T T
V-QF r SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES
A.
5 SITE PLAN 4 T�
l I€ OWN OF SOUTHOLD
rot A - NY
THE FIELDS AT MATTtYLtK
_ € LOT 4
� 'T D I -ems-' _ 2/5/2024
— ?VATI N It SPit" N REQUIRED � f
m �SANITARY YS® t} ' PROPOSED SANITARY PLAN
-IA
X12025
�`�`I;A�TFi E c L K.McL.EANA330CIATES,P.C.
12 ' _ t _ A.R. €dT e.m arum mmi.°�
MFfCFO 1 Sm= AS NOTED
� � R4 �.Br MF 1 pne JANIIARY 2024 S 1
i �.�'"-`�'�.-5#xr. >�-• RA5 [�.x,cG#1$3.JK�
^
�� �m �� � �� ��
Generated by RE��chec& - Software �� �� �� � � ��
��N��0�N�� N��� ��������� e�������������������
�—'n�w�� � ��� ���� m��n�° �-~��� ��� � N���� ���� F F,R 2 8 2024
CNJ/
Project Platinum Fields OfM8ttitU[k Lot Southold NY 11952 (;�Ii'��x�t����
Energy Code: 2018UECC
Location: Matuitmck, New York
Construction Type: Single-family
Project Type: New Construction
Orientation: Bldg. faces 90 deg. from North
Conditioned Floor Area: 3,4850t2
Glazing Area 1096
Climate Zone: 4 (5331 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
Fields ufMattituck. Lot 4 Platinum Building Design, Luc.
Southold, wYzIQ52
Compliance: 3.6%Better Than Code Maximum UA: 505 Your UA: 487 Maximum SHGC: 0.40 Your SHGC: 0.30
The%Better",Worse Than Code Index reflects how close t"compliance the house/s based""code trade-off rules.
/t DOES NOT provide""estimate m energy use",cost relative m°m/mmurn'""d°home.
S|ab'om-gradetradeoffsene mo yongercmns�dered in the UAo/perfori-nance compliance padh)n REScheck, sach syab'on-grode
essembUy i�n the spedfied dHmaLe zone must rineer.the min|mum energy code Insulation R-vo|ue and depth requinemenfts
Prop. Req. Prop. Req�
Assembly
axunoof: Cathedral Ceiling 858 35.0 oo 0.030 0.025 zn az
zxzO Roof: Cathedral Ceiling 1,630 35.0 0.0 0.030 0.026 49 42
Ambient Wall:wood Frame' zn" D.C. 3,215 15.0 3.0 0.061 0.050 171 168
Orientation: Unspecified
Front Door: Solid Door(under xnp6 glazing) an 0.200 0.320 4 O
Orientation: Unspecified
Windows:Vinyl Frame
sHGC: o.3O 394 0.300 0.320 zzo 120
Orientation: Unspecified
Garage Wall: Wood pname, z§^ o.c. 234 15.0 0.0 0.077 0.050 zO 14
orientation: Unspecified
Basement Stairs: Wood pn,me, 15" o.c. 315 13.0 0.0 0.082 0.050 24 zo
Orientation: Unspecified
Basement Door: Solid Door(under sn»6 glazing) 18 0.200 0.320 4 5
Orientation: Unspecified
Floor Over Basement:A||'wood]oist/Tmss 1.743 30.0 oo 0.033 0.047 so oz
Floor Over Garage:All-Wood Joist/Truss 440 30.0 0.0 0o33 0.047 15 21
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Michael Caruso - HERS Rater 2024-02-22
Name-Title Signature Date
Project Title: Platinum Fields of Mattituck Lot 4 Southold NY 11952 Report date: 02/22/24
Data filename: Page 2 of10
REScheck Software Version : REScheck-Web
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Veri
Section p Revie.a.�PlanValuefied Field V Value Complies?p? Comments/Assumptions..__."....."
&0Re .ID t",
:Construction�drawiPganandeview ❑Compliehes. willb met
9
Requirement
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the ❑Not Observable
building envelope.Thermal
envelope represented on ❑Not Applicable
construction documents.
_. ._ �._..............
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2, documentation demonstrate []Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems ❑Not Observable
Systems serving multiple ❑Not Applicable ;
dwelling units must demonstrate
311
compliance with the IECC
_ Commercial Provisions.
302 1, 'Heating and cooling equipment is Heating: Heating. "��ElComplies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2)2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable ;
Manual J or other methods Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) n� 2 Medium Impact(Tier 2) 3Low Impact(Tier 3)
Project Title: Platinum Fields of Mattituck Lot 4 Southold NY 11952 Report date: 02/22/24
Data filename: Page 3 of10
. °
�
section Foundation Inspection Complies? C o,rn me nts/AssumPti ons
3012.1 A protective covering is installed to UComplies Requirement will be met.
(FO1111, protect exposed exterior insulation ':DDoes Not
and extends a minimum o I f 6 in. below CINot Observable:
EINot Applicable
q Snow-and ice-melting system controls,[]Com plies Exception: Requirement is not applicable.
F01212 installed. E)Does Not
FINot Observable:
11Not Applicable
AdditionaUCmnmnments/Assmnmptisns:
Project Title: Platinum Fields ufMat1ituck Lot 4 Southold NYllg5Z Report date: 02/22/24
Data filename: Page 4orI0
Section
Plans
fied Frei Verified
Framing / Rough-in Inspection Val Vle ._ w Complies?ies Comments/Assumptions
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
_. _ _ .... .. . .......
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑DoesNot table for values.
402.3.3,
❑
402.5 Not Observable
[FR2]1 ❑Not Applicable
,
�...... . ................ . ... ....�
303.1.3 U-factors of fenestration products ❑Complies Requirement will be met.
[FR4]1 are determined in accordance " ❑Does Not
with the NFRC test procedure or ❑Not Observable
taken from the default table.
❑Not Applicable
._...__ ,.,,w. �... � w ....: w,..,... ._...�.__.... -_ �..........-.-..
402.4.1.1 'Air barrier and thermal barrier ❑Complies Requirement will be met.
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
[]Not Observable
..... �;.a
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
�AAMA/WDMA/CSA 101/I.S.2/A440 "
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies Requirement will be met.
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. []Not Observable
❑Not Applicable
_ ....... �� �,W .....m ..m ... __..............
403.3.1 Supply and return ducts in attics ' "' ❑Complies Requirement will be met.
[FR12]1 insulated >= R-8 where duct is "'❑Does Not
>= 3 inches in diameter and >_
R-6 where < 3 inches. Supply and []Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
,for< 3 inches in diameter.
403.3.2 Ducts, air handlers and filter ❑Complies Requirement will be met.
[FR13]1 boxes are sealed with ❑Does Not
;joints/seams compliant with ❑Not Observable
International Mechanical Code or
International Residential Code, as ❑Not Applicable
;applicable. _ _
403.3.5 Building cavities are not used as ❑Complies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
[]Not Observable
❑Not Applicable
._ ............
403.4 HVAC piping conveying fluids R- R ❑C'omplies Requirement will be met.
[FR17]2 above 105 °F or chilled fluids ❑Does Not
below 55 °F are insulated to >_R-
;��;; 3 I❑Not Observable
❑Not Applicable
_.... ........._.� _"�.
777
403 4 1 Protection of insulation on HVAC ❑Complies 'Requirement will be met.
[FR24]
1 piping, ❑D
oes Not
❑Not Observable
❑Not Applicable
4 0 5.3 HoRt3 water pipes are insulated to R R ElCo _pli _..eq re ...
p'p mplies Requirement will be met:
18]2 > es Not
, ❑Not Observable 9
❑Not Applicable
_.......
Hi h Im act(Tier 1) 2
Medium Impact 3 Low(Tier 2) Impact(TieriF7
3)
Project Title: Platinum Fields of Mattituck Lot 4 Southold NY 11952 Report date: 02/22/24
Data filename: Page 5 of10
Section
Flan Veriflueied.,,'. Field Verified tle �s
die Ifs. Framing 1 Stough to Inspection
1tur
.....e�,� � . . _.._._...� ...��._._ Complies?_....A_ �zrnura�► rrts�4ssucn —.
4016, Automatic or gravity dampers are [ Complies Requirement will be met.
[FRI912 installed on:ali outdoor air Oboes Not
intakes and exhausts.
[]Not observable
ONot Applicable
Additional Comments/Assumptions:
g p _ i'er It i �A drum Impact lT' ,.. i yEco _.p —......
�..i-Ri h Ise pa l�' �......��1�
per _ In�upact l 7le-r i)
Project Titie, Platinum Fields of Matt tuck Lot 4 Southold NY'11952 Report date; 02/22124
Data filename: Page 6 of1O
J
Section any Verified Field Verified
insulation Inspection P� Value Value Complies'? Comments/Assumptions
All instal Emmo__.
��e ICE led insulation ..�,,.... ...�.- . Doe',.lies �...�, _ a�....... -..._.. ...-...
is labeled ❑Comp' Requirement will be met.
[IN1 ] or the installed R-values s Not
;provided. ❑Not Observable
[]Not Applicable
402.1.1, Floor insulation R-value. R- R ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 ❑ Steel ❑ Steel j❑Not Observable
j❑Not Applicable
...... ............_. .... .. �,�� . .�. __ _e.,,.. .... .. �.......�. _
303 2 Floor insulation installed per ❑Co lies Requirement will be met.
402.2.8 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the O,Not Observable
; � underside of the subfloor,or floor
framing cavity insulation is in ❑Not Applicable
contact with the top side of �r `
i sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
_ members. _ _
402.1.1, Wall insulation value.If this is a R- R ❑C� _ mm the EnvelopeIT
�R �� ����������� �� �������-��������� omplies See the Assemblles
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall
t
[IN3]1 exterior,the exterior insulation ❑ ❑Mass Mass :[-]Not Observable
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
......................._..._... �.
303.2 �Wall insulation is installed per []Complies Requirement will be met.
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High
_. -_ _
i . ._. .
gh Impact(Tier 1) �2 Medium Impart(Tier 2) 3 Low Impact (Tier 3)
Project Title: Platinum Fields of Mattituck Lot 4 Southold NY 11952 Report date: 02/22/24
Data filename: Page 7 of10
Section
Value Value P Comments/Assumptions
s Verified Field Verified
& Re 1D
q Final Inspection Provisions w. _ _ R- ❑Comnlielse5. .... _. m....
p an �
402.1.1, Ceiling insulation R-value, R p See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel ❑Not Observable
402.2.E
❑
[FI1]1 Not Applicable
303.1.1.1, ,Ceiling insulation installed per ❑Com� plies Requirement......- —
will be met.
303.2 manufacturer's instructions. ❑Does Not
[FI2]1 Blown insulation marked every ❑Not Observable
300 ft2. Not
Applicable
402.2.3 — Vented attics with air permeable ❑Complies Requirement will be met.
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. :❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R ❑Complies Requirement will be met.
[F13]1 insulation >—R-value of the ❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa..<=5 ACH 50 ACH 50mmm— .IComplies `Requireme.Complies will be met.
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
❑Not Observable
❑Not Applicable
_... .......... ...... ..�
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Requirement will be met.
[FI27]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a I❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g, across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
_ handler enclosure.
403.3.4 Duct tightness test result of<=4 cfm/100 cf � —
g .______ ITIT—. � ....... m/100 ❑Complies �mmmmRequirement will be met.
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ❑Not Observable
,tests, verification may need to ❑Not Applicable
occur during Framing Inspection. _
403.3.2.1 I Air handler leakage designated � ❑Complies Requirement will be
_. met.
[FI24]1 by manufacturer at<=2%of ❑Does Not
design airflow.
[]Not Observable
❑Not Applicable
40::.. ,w..�,.�... .. ... ......
3.1.1 Programmable thermostats ❑Complies Requirement will be met.
[Fl9]2 installed for control of primary ❑Does Not
heating and cooling systems and ❑Not Observable
initially set by manufacturer to
code specifications. ' ❑Not Applicable
.W ...,e_ __...... a„. _ , ...........................
403.1.2 Heat pump thermostat installed []CompliesException: Requirement is
[FI10]2 on heat pumps. ❑Does Not not applicable.
[]Not Observable
❑Not Applicable
....... ���._ _ �., q,,, �M. ....... .._:
403.5.1 Circulating service hot water ❑Complies !Exception: Requirement is
[Fill]? systems have automatic or ❑Does Not not applicable.
accessible manual controls. ❑Not Observable
❑Not Applicable
�. d .m_..� mm
�gh Impact(Tier 1)—�2 Medium act Imp (Tier 2)— 3 Low Low Impact(Tier 3)
_
....... m_ .
Project Title: Platinum Fields of Mattituck Lot 4 Southold NY 11952 Report date: 02/22/24
Data filename: Page 8 of10
Section Plans Verified Field Verified
P
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
cal
on
ystem
403.6.11D falls not palm of tested lands)stud ❑D
❑C lies :Requirement
p eqment will be met.
oes Not
HVAC equipment meet efficacy
and air flow limits per Table []Not Observable
R403.6.1. ❑Not Applicable
403._... _ �.r pl g p ._..... Requirement
403.2 Hot water boilers supplying m heat ❑Com lies Exception:� quirement is
(FI2612 through one-or two-pipe heating ❑Does Not not applicable,.
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
403.5.1.1 Heated water c �. '... .. w�, .. .. ... o ...... ......_ ... �
temperature
circulation systems ❑Complies ,Exception: Requirement is
[F128]2 have a circulation pump.The ❑Does Not not applicable.
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- []Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
,pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automaticallyturn off the
pump
p
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems %� ❑Complies Exception: Requirement is
[F129]2 comply with IEEE 515.1 or UL ❑Does Not not applicable.
515. Controls automatically
adjust the energy input to the []Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping
.,. _...._ ��
403.5..2 Demand recirculation
_ -
water ❑Complies Exception. Reqq uirement is
[F13012 systems have controls that ❑Does Not not applicable.
manage operation of the pump ❑Not Observable
and limit the temperature of the
water entering the cold water ❑Not Applicable
piping to <= 1049F,
��.v..� ............ .. .. _-e_
heat recovery units ❑C
403.5.4 Drain water orplies Exception. Requirement is
[F131]2 tested in accordance with CSA ❑Does Not not applicable.
B55.1. Potable water-side ❑Not Observable
pressure loss of drain water heat
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
.. � OComplies Requirement will
m
404.1 90%or more of
permanent will be met.
[F16] 'fixtures have high efficacy lamps. ❑Does Not
❑Not Observable
[]Not Applicable
,.. ................
404.1.1 Fuel gas lighting systems have ❑Complies 'Exception: Requirement is
[F123]3 no continuous pilot light. ❑Does Not not applicable.
❑Not Observable
❑Not Applicable
_....................
_.__�
401.3 Compliance certificate posted. ❑Complies Requirement will be met.
[F17]2 ❑Does Not
❑Not Observable
❑Not Applicable
�1t ac Im 1i h t(Tier 1") 2ai Medium Irrwp ct�(Tier 2) 3 Low
..g ..p mpact(Tier 3)
Project Title: Platinum Fields of Mattituck Lot 4 Southold NY 11952 Report date: 02/22/24
Data filename: Page 9 of10
y
sE"CtiQrM �...,
Fti . Plansvaluefied Field Value
_._. ... _. surnptl ins
.fie ...
1303.3 .. � Manufacturer
Inspection i''eraiicrns Complies?
P e3' Requirement cement will
Final
manuals for ❑Com lies be met.
(FIl ') mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
e
Additional Comments/Assumptions:
1 High Im act(Tier 1 _ 2 Medium Impact(Tier 2) Low M
T _ p ow Impact(Tier 3)
Project Title: Platinum Fields of Mattituck Lot 4 Southold NY 11952 Report date: 02/22/24
Data filename: Page 10 of10
Energy
EffidencyCertificate
• •
Above-Grade Wall 18.00
Below-Grade Wall 0.00
Floor 30.00
Ceiling / Roof 35.00
Ductwork (unconditioned spaces):
Window 0.30 0.30
Door 0.20
SEMEN=
Heating System:
Cooling System:
Water Heater.
Name: Date:
Comments
W W SURVEY OF PROPERTY
ON THE
\ Z 893,18' SUBDIVISION MAP OF
'A �
c� A THE FIELDS AT MATTITUCK
LOT 4
FILED MARCH 31, 2006 AS MAP NO. 11370
LOT 3
SITUATE AT
1 ^� +��p z00.0z' MATTITUCK
FENCE ✓1«v78 1�r+�r E UTILITY
7145 x 70 7 j67..46u
�V� 67.60
EP 6Z39 TOWN OF SOUTHOLD
MTV ' 5' POST AND WIRE FENCE x -""""" t "" x 69.39ej
EPVTC 67.23 SUFFOLK COUNTY,NEW YORK
7156 z67.B7x67.B0S 19*41,45' E
10.00' AREA OF PARCEL = 35,096f SQ.FT. OR 0.806f ACRE
JC 6Z07EP 66.74
'' NOTES
1. MEASUREMENTS ARE IN ACCORDANCE WITH U.S STANDARDS.
$A,29 x6&' S x65,4'0 x66J1 'Ld 2. BEARINGS SHOWN ARE IN NEWYORK STATE PLANE COORDINATE SYSTEM NAD 1983,
LONGISLANDZONE.04 E33, ELEVATIONS SHOWN HEREON REFERENCE NAVD 1988.
e�w, 4, UNAUTHORIZED ALTERATION OR ADDITION TO SURVEY MAP BEARING ALICENSED
` TC 66.21 LAND SURVEYOR'S SEAL ISA VIOLATION OF SECTION 7209,SUBDIVISION 2,OF THE
Val 6699 FP 65.90 NEW YORK STATE EDUCATION LAW.
+e»•M A Q 5. ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF
11�y ¢ THE LAND SURVEYORS"EMBOSSED"OR"INKED"SEAL SHALL BE CONSIDERED TO BE
'- 'x 65,67' 3 VALID TRUE COPIES,.
U' :C3 6. CERTIFICATIONS INDICATEDHEREON SIGNIFYTHAT THIS SURVEY WAS PREPARED IN
- +•-t PROPANE � ACCORDANCE WITH THE EXISTING CODE OF PRACTICE FOR LAND SURVEYORS
TANK' � �""` ^�..... x 6� � ADOPTED BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND
{ .. x 65J4 R SURVEYORS" SAID CERTIFICATIONS SHALL RUN ONLY TO THE PERSON FOR WHOM
x 64.44 THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY,
GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON AND TO THE
6512 J *yv,� ASSIGNEES OF THE LENDING INSTITUTION. CERTIFICATIONS ARE NOT TRANSFERABLE
d TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS.
a
U Z I�
.'kk p Z RIGHTS-OF-WAY NOT SHOWN ARE NOT CERTIFIED.
3 r' ^ 8. THE SURVEY CLOSES MATHEMATICALLY.
N t 4 x65.53 \ 9. UNDERGROUND UTILITIES IF SHOWN ON THIS SURVEY ARE FROM UTILITY MARKOUT
W —4 65.10 TC 64.83 LOCATED ON THE GROUND AND/OR RECORD PLANS. BEFORE ANY EXCAVATION IS TO
U CD /// \ x EP 64.59 BEGIN,ALL UNDERGROUND UTILITIES SHOULD BE VERIFIED AS TO THEIR LOCATION,
Z. r.{ x64.32 SIZE AND TYPE BY THE RESPECTIVE UTILITY COMPANIES..
0
WOODED V 10. THIS SURVEY WAS MADE WITHOUT THE BENEFIT OF A TITLE REPORT.SUBJECT TO
Z (U " ANY EASEMENTS,CONDITIONS OR ENCUMBRANCES AN UPDATED TITLE SEARCH MAY
q oc� x6412 `" REVEAL..
Q Z
W 65x0
N
` O Ii
Q TC 6399
x 64,16 MON EP 6375 LEGEND
64.18
Fa � x 64.21 EP ei53 —�- °OVERHEAD WIRES
^ELECTRIC MANHOLE
64.04 ,,:»"' BIB ^BELGILM BLOCK
� TC TOP CURB
x 64,17
Sol EP EDGE OF PAVEMENT
x64.18° •SPOT ELEVATION
UTILITY POLE
° . .. . . ^WATER METER
BOULDER
OF OF NEB 10
" t. r x 6354
LOT 5 * 4 " 021211241 T.L.S I Revised tax map designation T.L.S.
t f REVISIONS
b, Town of Southold
CERTIFIED TO: Suffolk County, New York
�KExpress Abstract Development LLC �� v Stanley Road
rEE Mattituck, New York
�0's LAND Topographic Survej
SUFFOLK COUNTY REAL PROPERTY TAX MAP NO. 1 hereby certify that this map was made from an actual survey
po DISTRICT 1000 MaN, completed b me on 0112412024. 0 GRAPE 30 SCALE L. K. MCLEAN ASSOCIATES,
p Y
60 CONSULTING ENGINEERS & LAND SUR
SECTION 106.00 Feet 437 SO. COUNTRY ROAD. BROOKBAVEN. NEBLOCK 08.00 Fleur survey By.J.P./JP,LLOT 058.000 TAMARA L. STILLMAN,P.L.S. IN FEET ) 1 D—n By, D.M. Date: 0113012024
P+\20099.000 Flelds B Mattltuck Engr 8 Survey\Survey Dept\Drawings\LOT 4\20099.000 Survey 01-24-2024.dwg 21PI12024 1L32 AM Vin Carnsltl NYSPLSNo. 50528 1 ineh = 30 f1. Approved By, T.L.S. Fnetoo. 20099.000