Loading...
HomeMy WebLinkAbout49829-Z �o�OSu FF OlA'CAGy Town of Southold 1/14/2024 P.O.Box 1179 o - 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44871 Date: 1/14/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2100 Greenway E,Orient SCTM#: 473889 Sec/Block/Lot: 15.-2-3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/18/2023 pursuant to which Building Permit No. 49829 dated 10/4/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as aapplied for. The certificate is issued to Tamaro Jr,Richard&Lana of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49829 12/19/2023 PLUMBERS CERTIFICATION DATED A e Signature M TOWN OF SOUTHOLD BUILDING DEPARTMENT y x " TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49829 Date: 10/4/2023 Permission is hereby granted to: Tamaro Jr, Richard 2100 Greenway E Orient, NY 11957 To: install roof-mounted solar panels to existing single-family dwelling as applied for. 1 / At premises located at: 2100 Greenway E, Orient SCTM #473889 Sec/Block/Lot# 15.-2-3 Pursuant to application dated 9/18/2023 and approved by the Building Inspector. To expire on 41412025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector of so�ryol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlinl-town.southold.ny.us Southold,NY 11971-0959 ��U N,�a v BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Richard Tamaro Jr Address: 2100 Greenway E city:Orient st: NY zip: 11957 Building Permit#: 49829 Section: 15 Block: 2 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Surrey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 10.53kW Roof Mounted PV Solar Energy System w/ (26) gcell gpeakDuo MLG10 - 405W Modules AC Disconnect, Combiner Panel Notes: Solar Inspector Signature: Date: December 19, 2023 S.Devlin-Cert Electrical Compliance Form Q 1 pF SOU V�� r 9 a a0 greeA # # TOWN OF SOUTHOLD BUILDING D PT. °`ycou 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [XI ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: .50[0,4- DATE l- (3 ' 023 INSPECTOR t �nICLI� OF SOUTy�Io - — - --- — "� # TOWN OF SOUTHOLD BUILDING DEPT. rourm, 631-765-1802 -INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIONCAAULKING [ ] FRAMING /STRAPPING [ FINAL Q4vl, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: � � 6 G91A, 1 DATER INSPECTOR Zoho Sign Document ID:2A768FFA-HLJ7SVNF-VOYXJLQGOZTTMPYODFAOOBOLUEHENJH3LW D JAN - 8 ?024 Town of Southold November 13th 2023 Building Department �P �d'"'t� 'i Town Hall Annex Building 'Fc.°�sa c� h,�.«<s➢�-3 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Subject: Roof Mounted Solar Panels at the Tamaro Residence, 2100 Greenway E. Orient, NY 11957 To Town of Southold: I reviewed the solar energy system installation in the subject topic on November 13th, 2023. The units have been installed per the manufacturer's instructions and the construction drawings approved by the Building Department, Town of Southold, New York. The solar panel installation is in compliance with the requirements of the 2020 Building Code of New York State, the 2017 National Electric Code, SEVASCE 07-16 "Minimum Design Loads for Buildings and Other Structures", NFPA Standard 70, and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. Markings in accordance with Section 690.53 of the National Electrical Code are provided. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission, and conforms with reasonable standards of practice with the view to safeguarding life, health, property, and public welfare. Sincerely, Gennaro Anthony Giustra. P.E. OF NEW y Great Eastern Services, Inc. Pg0 A c PO Box 240 24 Harvey Rd w Riverhead, NY 11901 2 2 Mobile: 631.235.0189 �o 103443 Email: jerrygiustra@gmail.com' AR�FEssioNPv I LELD INSPECTION REPORT DATE COMMENTS �ro FOUNDATION (1ST) -` 3 ------------------------------- C FOUNDATION (2ND) O G cn H ROUGH FRAMING& H PLUMBING t N W . Or INSULATION PER N.Y. STATE ENERGY CODE FINAL r ,l �/ oV., �b r ADDITIONAL COMMENTS A ro 2.3 a,'„��cC, P t co r4,/ec- Ire,c.� G5F \ -% r'r rn 1 � k ro O x H x e ro H - I i���uFFol�Q9 TOWN OF SOUTHOLD —BUILDING DEPARTMENT y Town Fall Annex 54375 Main Road P. ®. Box 1179 Southold,NY 11971-0959 � ,o• ���, �' Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gv Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only E E I V E D PERMIT NO. Building Inspector: SEP 18 20 23 Applications and forms must be filled out fn Eheir entirety:Incomplete applications will not be accepted: Where the Applicant.is not the owner,an Building Department Ownees Authorkation:form.(Page 21 shall,be completed.- Town of Southold Date: 1 OWNER(S).00 PROPERTY: _ Name.--, -rL _n� _ SCTM#1000- ® � 5_ (�U Z, Oct 0p3•oc)o Project Address: a)o0 D rl -e-� y, 11 qs Phone#: b3 1 _1-7c) 1 plod Email: ��rn 1 n 0 4l� �02� ;S ,(� 4 Mailing Address: C9 l D .0 C-)Ce-eW LLI €&s+ O nit/ C �S CONTACT PERSON:; .... -A Name: Mailing Address: 7 -70 �5 et A .-h WC� � Phone#: �� I _77 _ -7 193 Email: ::DESIGN;PROFESSIONAL INFORMATION:' Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION;, .. _ . Mailing Address: Q B�LOIC)L �t 'I✓(-4 4aCK, I — Phone#: �� �' • '-7c/ a 2 Email:. 11 a _ o DESCRIPTION.OF PROPOSED CONSTRUCTION ❑New Str`ucctture ❑Additio ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Other "SO I 6t-e V 6 $ 3 0-1 g, Will the lot be re-graded? ❑Yes,�NNo Will excess fill be removed from premises? ❑Yes PVo 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑YesSXNo IF YES, PROVIDE A COPY. 0 Check Box After Reading: The owner/contracttir/design professional is responsible for all drainage�and storm.water issues as provided by Chapter 236 of the Town Code. APPLICATION 15 HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described:The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are, punishable.as a Class A misdemeanor pursuant to Section.210.4S of the New York State Penal Law. Application Submitted By(print name): L o rro i rl e-,-b! P authorized Agent ❑Owner Signature of Applicant: &&AAA�IlLt `�/�, � Date: STATE OF NEW YORK) SS: COUNTY OF LL-� ) Lb Y-r't -nc,-b! Pei t-&, being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above above named, (S)heisthe Ln+MQW (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 1 day of s jPIC-I'll �r'r- , 20 Z� No Public LOUIS J ROMFO PROPERTY OWNER AUTHORIZATION Notary Public,State oi Piew York No.01 ROF ,-613 (Where the applicant is not the owner) C Qualified in S ik County Commission Expi-- —mber 17,20Zt- 1, I -►'Yla-YO 1—�n�-- residing at_ 02 E^44 01J� do hereby authorize Oe-m-e ' � r LA-C. to apply on my behalf the Town of Southold Building Department for approval as described herein. G� o 5 f 6 oZ Owner's Signature f Date L � Tc-Ma-VD LOUIS J ROMEO Notary Public,State of New York Print Owner s Name No.01R06314813 in Suffolk County Commission iExpir s November 17,20 e jg 2 o�Og�fiFO[xc�G BUILDING DEPARTMENT- Electrical Inspector ,y. .- TOWN OF SOUTHOLD o = Town Hall Annex - 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 y�j0 a0� Telephone (631) 765-1802 - FAX (631) 765-9502 1 ' rogerr(aD-southoldtownny.aov - seandCaDsoutholdtownny.Aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: q f 1,;2, J.:43 Company Name: E 1e-r)'1cn -- Electrician's Name: :6,_Md',f License No.: 9 r M C' Elec. email: t_-rm 4S �s ,C cry) Elec. Phone No: 6,31 --�-7 7 q 93 ®1 request an email copy of Certificate of Compliance Elec. Address.:'IL4 '7 0 60vl. ik- N LI. 119 JOB SITE INFORMATION (All Information Required) Name: Lo-ok Address: o2 100 r w EIL4 n r' ,y ll c Cross Street: Phone No.: 4061 --779 - ? 9 93 BIdg.Permit#: email:,,- ,' -� a s S,C Tax Map District: 1000 Section: 15.00 Block: Q a,eO Lot: 003 , au BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YESNO Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES r NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New ServiceOFire ReconnectE]Flood ReconnectOService Reconnect OUnderground00verhead # Underground Laterals 1 2 D H Frame Pole Work done on Service? R Y RN Additional Information: -eI VLL h roo•F 6` c vLyi4,ed,, lo v -s yiS4e-rn 10, S3�--LAJ Z�M0 4"IC-S A Q ce.GI - a DL(O 6 y< t--r 4- C710 +��S +a -r {-cc, ) PAYMENT DUE WITH APPLICATION rro�-e,1 X.(zt �o t BUILDING ®EPARTMENT-T®VVI� OF S®UTB�®L®al Inspector Town Hall Annex - 54375 Main Road - PO Sox 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCD_southoldtownny.gov sea nd(d-)southoldtownny.gov -r�rx:L APPLICATION FOR ELECTRICAL' INSPECTION ELECTRICIAN INFORMATION (Au Information Required) Date: C1 Company Name: El _rrIfn t-) L ..- Electrician's Name: �� License No.: g C1 ,-' Elec. email: S , Elec. Phone No: (� j s 1 q . 7 q ri,3 [0 1 request an email copy of Certificate of Compliance Elec. Address.:I d-1 r7 C .t,)Iui t . L ry1&. �Ac i\S_q- JOB SITE INFORMATION (All Information Required) Name: L o-n& Q 1�L,trn Address: 1 Oo r_� Lv Cross Street: Phone No.: ► ---?79 e 7 7 93 Bldg.Permit #: email: Tax Map District.- 1000 Section: 15,00 Block: (� . 00 Lot: OU3 , �u BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply. Is job ready for inspection?: ❑ YESNO []Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES NO Issued On Tempi Informaflon: (All information required) Service Size Ph03 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? Y N Additional Information: P) roe - vyic txri4e6k, �Sc I e_;, io V, __S°s4c.r7l 10. 53 ��3 PAYMENT DUE WITH APPLICATION r CERTIFICATE OF LIABILITY INSURANCE DATE(MM70/1'°12 0'13 THIS CERTIFICATE IS ISSUED AS A (NATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW- THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT ROBERT S. FEDE INSURANCE AGENCY NAME: PHONE - - FAX 23 GREEN STREET,SUITE 102 WC,No ETA. WC.No): E-MAIL HUNTINGTON,NY 11743 ADDRESS: ` ROBERTS.FEDE INSURANCE INSU SI AFFORDING COVERAGE 4&24210 A:ATLANTIC CASUALTY INS.CO. INSUR ED INSURERjF: Element Energy LLC INSURER DBA ELEMENT ENERGY SYSTEMS IrvsuREI,7470 SOUND AVENUE INSURER MATTITUCK,NY 11952 INSURER COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLANS. ILTSRR TYPE OF INSURANCE DDL POLICY NUMBER MIDD EFF POLICY EXP LIMITS COMMERCIAL GENERAL LIABILITY L1480036873 EALH OCCURRENCE s 3,000,000 A X X 7114/2023 7/14=4 CLAIMS-1AAilE OCCUR PREMISES Faao[urrence $ 100.000 81AA3892038 MED EXP(An are person) $ 5000 X COntraCtual Lia 7/19/2022 7/19/2024 PERSONAL a AOV INA JRY 3 3000000 MOTHER: LAGGREGATE LIMIT APPLIES PERGC-tdERALAGGREGATE $ 3,ODt},(]fl0 POLICY KI PER LOG ! PRODUCTS-CONPIOPAGG s 1{ s AUTOMOBILE I MAN Ty COMBINED SINGLE LIMIT f Fa accident ANY AUTO e001LY INJURY(Par person) s OWNED SCHEDULED AUTOS ONLY AUTOS BOOILY INJURY(Per arrJdeat) $ HIRED NON-OWNED PROPERTY DAMAGE ONLY AUTOS ONLY $ $ UMBRELLA LIAI OCCUR EACH OCCURRENCE $ EXCESS WtB 3 HCLAMPS- MADE l AGGREGATE $ DED It I RETENTICN$ $ B KE WORR$COMPENSATION AND AND EMPLOYERS'UABIITRI V PER ER OFRCERIMEMBER EXCLUDED? N I A ANY PROPRIETORIPARTNEEXECUTIVE �,I N 7113/2023 7/13/2024 EL EACH ACCIDENT $ 1.000.000 tMandalwy in N EL DISEASE-EA EMPLOYE $ Hi If yes,desalts under DESCRIPTION OF OFERAMCNS below EL DISEASE-POLICY L1MR $ NY State DBL DBL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS i VEMCLES(ACORD 1101,Addltlenal Remarks Schedule,may be atteehW Ir store space Is requ)aed) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability- 30 day notice of cancellation applies. r" CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southard,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE RaUes^�S. Fed,& C 1988-2015 ACORD CORPORATION. All rights reserved. ernnn�c nn�arn�l Tk-Arson 4. .,i I...�. .:m. . . . .o�-4 Arson NYSIF Now York State Insurance Fund PO Box 66699,Albany,NY 12206 nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) A A A A A A 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 0 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER PCERT]FiCATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07113/2023 TO 07/13/2024 711112023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/11MNW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GNE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WANE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT ZCE FUND 4 DIRECTOR,INSURANCE FUND UNDERWRITfNG Yoee i Workers'Compensation sTaT CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 - 1 c.Federal Employer Identification Number of Insured if Work Location of Insured(Onlynsqulrtgai coverage is specrllcally limited to or Social Security Number contain locations in New York State,i.e.,Wrap-Up Palicy) 823336604 2.Name and Address of Entity Requesting Proof of Coverage i 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD ' 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"Ia" -SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/0112023 to 12r3112024 4. Policy provides the following benefits: ® A Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employers employees: ( Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By (Signature of iesurarce carriers authorized representative or NYS Licensed Insurance Agent ofthat insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the Insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it direddy to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 6200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only If Box 48,4C or 50 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) I Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DS-120.1.Insurance brokers are NOT authorized to Issue this farm. DB-12fl.1 (12-21) Zoho Sign Document ID:2A768FFA-MUC;YFL5H8M15(UW2UMLHYSCTXUXUY55PIZA7YUTKVLTY Town of Southold August 4th, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Tamaro Residence, 2100 Greenway E. Orient, NY 11957 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.7 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. of NEw Great Eastern Services, Inc. Q�� o A yO PO Box 240 CO 24 Harvey Rd r* Riverhead, NY 11901 m w Mobile: 631.235.0189 ZN Email: jerrygiustra@gmail.com A 10344' SS1111 I Zoho Sign Document ID:2A768FFA-MOCYFL5H8M1SGW2CMLHYSCTXQXCYS5PIZA7YQTKVLTY EQad SCOPE OF WORK DESIGN 4 DRAFTING BY: v I 1 �V I\I\ ---'-� � ELEMENT ENERGY LLC �oNN yopK TO INSTALL A 10.53 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT TAMARO RESIDENCE, -=rieN REVIEW BY J.M.NABCEP CERTIFIE LOCATED AT 2 100 GREENWAY EAST, ORIENT, NY 1 1957. 051 1 1 2-1 29 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH _ __ - THE EXISTING ELECTRICAL SERVICE EQUIPMENT. � _. .. . ....... " REVISIONS DE5CRIP­I0N DATE REV ORIGINAL oaoa-202s SYSTEM RATING Islam 10.53 10.53 kW DC STC iMr S Orient EQUIPMENT SUMMARY �„ " 2G QCELL Q.PEAK DUO BLK ML-G 10+405 WATT PV MODULES 2G ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS ® CONTRACTOR I IRONRIDGE XK 100 MOUNTING SYSTEM 6reenpo` SKEET INDEX ELEMENT ENERGY, LLC. Deng °��°�°ry 7470 SOUND AVE PV-I COVER MATTITUCK, NY 1 1952 PV-2 SITE PLAN PROJECT LOCATION LICENSE # G74G I-HI PV-3 ROOF PV LAYOUT LICENSE # 52G89-ME PV-4 STRUCTURAL/DETAILS 8 SECTIONS PV-5 3-LINE ELECTRICAL DIAGRAM PV-G LABELS GOVERNING CODES - °V NEW E Gso�� ,r,Q OA G 2017 NATIONAL ELECTRICAL CODE. e C� r F' FY 2020 RESIDENTIAL CODE OF NEW YORK STATE. nLu 2020 FIRE CODE OF NEW YORK STATE. ASCE 7-1 G AND NFPA-70. UNDERWRITERS LABORATORIES(UL)STANDARDS �03443,per 44$ OSHA 29 CFR 1 510.2G9 RO�SS%pNP GENERAL NOTES p� ry ELECTRICAL INSPECTION REQUIRED PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT p lLl THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE U Q Ln HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK Z Lu AGREE THE SAME. AERIAL VIEW W _ 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED Q APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM W Z CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, g AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES O W z 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND cn ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO o O COMMENCING WITH WORK. APP• •0 ED AS NOTED ILJ JURISDICTION. 1 1 . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR P�C� COMPLY WITH ALL CODES OF 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS Q / O Q O W MAINTAINING SAFETY ON THE JOB SITE DURING THE DA WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS k B•P! NEW YORK STATE & TOWN CODES QFLI THE CONTRACTOR SHALL STOP WORK AND NOTIFYTHE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND FEE—� J �By. AS REQUIRED AND CONDITIONS OF ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION.THIS SHALL INCLUDE, BUT ARE NOT CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, NOTIFYBUILDiNG DEPARTMENTAT Ann" RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY 631 765-'1802 8AM TO 4PM FOR THE SHEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE FOLLOWING INSPECTIONS- ,trt FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT I (�PC4NNING BOARD COVER SPECIFICATIONS. CONSTRUCTION. I. FOUNDATION-TWO REQUIRED - 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE L' TOWNT STEES G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING FOR POURED CONCRETE UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 2. ROUGH-FRAMING&PLUMBINQ nN NYS CODES *REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND 3. INSULATION 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. 4. FINAL-CONSTRUCTION MUST DRAWING SCALE CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S ,g 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS . CERTIFICATION OF THESE PLANS. BE COMPLETE FOR C.O UO CUFANCY OCR WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON �I 8.THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. ALL CONSTRUCTION SHALL MEET THE I V •T•5 SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED REQUIREMENTS OFTHE CODES OF NEW USE IS UNLAWFUL PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS.THE FACILITY IS TO BE YORK STATE. NOT RESPONSIBLE FOR WITHOUT CERTIFIC: THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THIS PROJECT DESIGN OR CONSTRUCTON ERRORS SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF (� /� A EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. OF OCCUt[�1"'�NCY PV— RESULT OF HIS WORK. TAX MAP: 100001 5000200003000 Zoho Sign Document ID:2A768FFA-MOCYFL5H8M1 SGW2CMLHYSCTXQXCYS5PIZA7YQTKVLTY LEGEND p� TAX MAP: 10000 15000200003000 DESIGN 4 DRAFTING BY: ®o EYJS71NG UTILITY METER /V ELEMENT ENERGY LLC MAIN SERVICE PANEL 0. REVIEW BY N ECEP CERTIFIE O51 NEW PV SUB—PANELS I A/C DISCONNECT COMBINER INVERTERS GND ELECTRODE 270 Q SIONS ME PV MODULE 240o s ojl� DATE REV D120. / [708-04-2023 RACKING RAIL 210 o 12 p o 0 ATTACHMENT POINT '800�SOo ---RAFTERS -*--ROOF PITCH ANGLE / GMSUNRUN METER j ®VENT 0PLUMBING VENT m ®SKY LIGHT m ®CHIMNEY ACCE55 ROOF cDi/ CONTRACTOR �OO�DSHINGLES j ELEMENT ENERGY, LLC. ❑POTENTIAL SHADING ISSUES Ep TRIM/RFJAOVE AS NECESSARY D/ 7470 SOUND AVE 3G"x 36"GROUND ACCE55 TYP. MATTITUCK, NY 1 105 LICENSE # G74G 1-111 LICENSE # 52G89-ME j i ji / F NE tV C�2 �e ACCE55 ROOF �OAROFESSIONA PROJECT NAME I� fL W ` v, L _ L U Q Ln w z w Lu oLLJ w Z D/ ° L cD z ® 0 �o w o F Q N O ® � SHEET NAME ® EW PV AC D15CONNECT 15TING INDOOR MAIN /READILY ACCE5515LE Or EXTERNAL ELECTRICAL SERVICE PANEL SITE FLAN I5TING UTILITY METER 'NOTE ON H-FRAME 1 .)THE ROOF 5ETBACK/PATHWAY SHALL NOT BE AUTOMATIC TRANSFANSF ER SWITCH REQUIRED ON ROOF-SLOPES WHERE THE ON H-FRAME DRAWING SCALE OPPOSING OR ADJACENT ROOF SLOPE 15 AN ACCE55 ROOF IN ACCORDANCE WITH R324.G.1 EXCEPTION OF 2020 NYS RE51DENTIAL CODE. I/sjll = I I-OII CONSTRUCTION NOTES V 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NUMBER MANUFACTURERS INSTALLATION INSTRUCTIONS. D\ �_n 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. r V/ G 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Zoho Sign Document ID:2A768FFA-MOCYFL5H8M1SGW2CMLHYSCTXQXCYS5PIZA7YQTKVLTY CONSTRUCTION SUMMARY DESIGN 8 DRAFTING BY: (2G) QCELL Q.PEAK DUO BLK ML-G 1 0+ 400 WATT PV MODULES ELEMENT ENERGY LLC P.TIFIE (DIMENSIONS: 74"X 4 1 .1"X I .3") REVIEW BY J.M.NABCEP CE(2G) ENPHASE IQB ARRAY#2 os I l l z-I zePLUS-72-2-US MICRO INVERTERS I O MODULES (48)ATTACHMENT POINTS @ G4"O.C. MAX. 18° PITCH (150.2) LF IRONRIDGE XR 100 MOUNTING SYSTEM. 70°AZIMUTH REV1510N5 ROOF TYPE: ASPHALT SHINGLE(SINGLE LAYER) DESCRIPTION DATE REV CONSTRUCTION NOTE5 ORIGINAL 08-04-2023 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE , WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. % z 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. j CONTRACTOR rn/ MIXAccess Poor, j ELEMENT ENERGY, LLC. 7470 SOUND AVE N% MATTITUCK, NY 1 155 3G"x 30 GROUND ACCESS TYP. LICENSE # 52G85-ME oo NSpy yo e j ZN � C9 F �A 103443 / / � ACCESS ROOF �OrESS1oNP� PROJECT NAME LU Ln FIRE/5U!,ACK @/RI/DGE /j/////�j// W W W V J ARRAY#I I G MODULES 23° PITCH V PANEL TYP. g lW z >— I GO'AZIMUTH (I/ ILJ Z ICRO-INVERTER TYP. 0 OLU °� o Ln o Q O LLJ LEGEND o �/ O �'27po I ® o STING UTILITY METER (V O Q ®EXIMAIN SERVICE PANEL 240° NEW PV SUB-PANELS goo C A/C DISCONNECT COMBINER SHEET NAME 2loo D 120o ` ® TRING/CONNECTION TYP. INVERTERS 1So ONO ELECTRODE 3 ® EW PV AC DISCONNECT 15TING INDOOR MAIN PV MODULE PV LAYOUT /READILY ACCESSIBLE B EXTERNAL ELECTRICAL SERVICE PANEL —RACKING RAIL 15TING UTILITY METER O ATTACHMENT POINT ON H-FRAME _ --RAFTERS 15TING AUTOMATIC DRAWING SCALE TRANSFER SWITCH —ROOF PITCH ANGLE ON H-FRAME � SUNRUN METER I/QII _ I I-oIl ®�T Vf 'NOTE 0PLUMBING VENT 1.)THE ROOF SETBACWATHWAY SHALL NOT BE REQUIRED ON ROOF-SLOPES WHERE THE ®SKY LIGHT SHEET NUMBER OPPOSING OR ADJACENT ROOF SLOPE IS AN ®CHIMNEY 2 ACCESS ROOF IN ACCORDANCE WITH R324.G.I ®COMPOSITE SHINGLES PV-3 GOOD CONDITION EXCEPTION OF 2020 NYS RESIDENTIAL CODE. TAX MAP: 10000 15000200003000 POTENTIAL SHADING ISSUES O TRIM/REMOVE AS NECESSARY Zoho Sign Document ID:2A768FFA-MOCYFL5H8MiSGW2CMLHYSCTXQXCYS5PIZA7YQTKVLTY LOAD CALCULATION ARRAY#I ARRAY#2 ITEM DESCRIPTION ARRAY#1-2 DESIGN a DRAFTING BY: RB Ricicie Bear/Board 2"X 8" D. FIR ELEMENT ENERGY LLC R Rafter 2"X G" D. FIR P, I G"O.C. REVIEW BY J.M.NA13CEPCERTIFIE MODULE WEIGHT(Lbs) 48.4 48.4 (D) Deckln 051112-129 5/8" PLYWOOD #OF MODULES I G 10 P Pitch 23' J Ceiling J015t 2"X G" D. FIR 1 G"O.C. REV1510N5 TOTAL MODULE WEIGHT(Lbs) 774.4 454.0 C) Collar TICS 2"X 4" D. FIR 48"O.C. DE5CRInON DATE REV TOTAL LENGTH OF RAIL(Ft) 1 10.9 G9.3 h horizontal 5 an of R 1 43" MAX ORIGINAL 08-04-2023 RAIL WEIGHT PER FOOT(Lbs) O.G8 O.GB TOTAL RAIL WEIGHT(Lbs) 75.4 47.1 R RB #OF STRANDOFF5 32 1 G (D) WEIGHT PER 5TRANDOFF(Lbs) 2 2 TOTAL STANDOFF WEIGHT(Lbs) G4 32 TOTAL ARRAY WEIGHT(Lbs) 91 3.5 5G3.I POINT LOAD(Lbs) 28.G 35.2 CONTRACTOR TOTAL ARRAY AREA(Sct Ft) 342.G 214.1 ELEMENT ENERGY, LLC. 7470 SOUND AVE ARRAY DEAD LOAD(Lbs/Sct Ft) 2.7 2.G ( ) MATTITUCK, NY 1 1952 WIND DESIGN SUBJECT TO DAMAGE FROM LICENSE # G74G I-HI GROUND SEISMIC WINTER ICE BARRIER AIR MEAN (C) LICENSE # 52G59-ME SNOW d Special Windborne DESIGN Frost DESIGN UNDERLAYMEN7 FLOOD FREEZING ANNUAL e Speed Topographic wind debris r a line c e h FIAZARDSg i LOAD (mph) effectsk CATEGORY Weathering Termi[e TEMP REQUIRED INDEX' TEMPI region' zone'" depthb OF NEVj, 20 140 NO NO NO B SEVERE 3 FT 15°F YES ZONE X 599 51°F �Q a�0 A G7GS0 MANUALJ DESIGN CRITERIA^ E:� �e �' h Winter Summer Altitude Indoor temperature nure coo Heating ( ) = = UJ Elevation Latitude heating cooling correction factor design ttling temperature m LU temperature difference Z� 108 FT 41°N 15'F 86°F 1.00 70°F 75°F 55°F (J) 703443 Cooling Wind Wind Coincident Daily Winter Summer O N � �SS10 P temperature difference velocity velocity heating cooling wet bulb range humidity humidity 11°F 15 MPH 7.5 MPH 72-F MEDIUM(M) 40% 32 GR @50%RH PROJECT NAME For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL n 0O LU U_ U L(� a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength z LU required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined W W from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. Q Q b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction N — — shall fill in the frost line depth column with the minimum depth of footing below finish grade. (f C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. W Z } d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined J �/ W z on a site specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York MODULE MOUNTING CLAMP O State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also LLJ see Figure R301.2(1).] 5OLAR MODULE 0) Q z f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. SraNLEss STEEL 3/8" O W g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New BOLT AND NUT 0 0 York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Q Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: F— CV O i.The accompanying Flood Insurance Rate Map(FIRM), ii.Flood Boundary and Floodway Map(FBFM),and NRIDGE ALUMINUM RAIL iii.Related supporting data along with any revisions thereto. ALUMINUM"U'BRACKEr SHEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ALUMINUM FLA511ING effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." STRUCTURAL i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method ASPHALT SHINGLE ROOF (Base 32°F)" 5/1 G".G"5TAMLE55 k. -In accordance with Section R301.2.1.5,where there is local historical data documentingstructural damage to buildings due to topographic winds speed-up effects,the STEEL LAG BOLT WITH 9 9P P z 1/2"MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION 5EALED DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the A5 N OTE D table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table la or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. D. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet SHEET NUMBER (') See Figure R301.2(4)B. PV-4 TAX MAP: 10000 15000200003000 MOUNTING DETAIL n Zoho Sign Document ID:2A768FFA-MOCYFL5H8MiSGW2CMLHYSCTXQXCYS5PIZA7YQTKVLTY DE51GN 4 DRAFTING BY: ROOF-MOUNTED 50LAR ARRAY ON THE MAIN HOUSE 10.53 kW POINT OF INTERCONNECTION ELEMENT ENERGY LLC PER NEC 240.2 1(13)(1)6 G90.G4(A) (2G)QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES LENGTH or TAP CONDUCTORS REVIEW BY J.M.NABCEP CERTIFIE (2)STRINGS OF(13)MICRO-INVERTERS SHALL NOT EXCEED 10 FT 05) 1)2-129 '(2)STRINGS TOTAL TO UTILITY GRID REVISIONS STRING # I DE5CRIPTI0N DATE REV - - - - - - - - - - ORIGINAL 06-04-2023 r- ---------------- -- I - BIf DIIR CTIONAL I I I METER 1- ------------------- 1-PHASE.240 V I 1 N I I I MAIN SERVICE DISCONNECT 240 V.200 A CONTRACTOR I - ------- - MAIN SERVICEDISCONNEGT ELEMENT ENERGY, LLC. 11140 200 A 7470 SOUND AVE ENPHA5E BRANCH MICRO-INVERTER MATTITUCK, NY I 1952 CIRCUIT CABLE TYPICAL ENPHA5E IQ8PLU5-72-2-US I 240 VAC. 1.21 A LICENSE # G74G I-HI 97%CEC-WEIGHTED EFF. ENPHA5E AC COMBINER BOX AC DISCONNECT NEMA G.UL LISTED LICENSE # 52G89-ME 240 VAC.GO A TYPICAL t NEMA 3R.UL LISTED 5Q D D223NR5 (2)20 A DOUBLE POLE BREAKERS 240 VAC.GO A NEMA 3R.UL LISTED OF NEIN N L2 L I N L2 I I (2)40 A PU5E5 P� O A G Gr� TTTTTT 20A I 20A 40A GENERATOR CO I I i- -� K I W MAIN SERVICE PANEL 2 Z N N AUTOMATIC I I-PH.TRANSFER 5MTCH 1 3-W 240 VAC 3 !` L1 r -- r' ----- G ---------- --------------- O 0344 G N L2 I N I-Prl.3-W N 200 A A �. I zoo vac ROFESSIONA ( I G zoo A IG - -� EXISTING GROUNDING I I EXISTING GROUNDIN PROJECT NAME --ELECTRODE SYSTEM ELECTRODE SYSTEM W I- t, 1'------- --------J I � U Ln l I 1 - Ln z w IW- W �- L ------ -------------J C) WIRE $ CONDUIT SCHEDULE ct) Q w z CIRCUIT CIRCUIT Q CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% �/ W z I.D.# ORIGIN DESTINATION 51ZE PER POLE QUANTITY DEBATE INSULATION 51ZE QUANTITY INSULATION (CU/AL) TYPE 51ZE TEMP DEBATE DISTANCE O 310.15(B)(3) 3 10.1 5(B)(20(3c) O ../ I INVERTERS COMBINER PANEL AWG#1 2 1 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR 3/4" 559C 0.84 90 FT 2.84% p UI OR EMT N Q z 2 COMBINER PANEL AC D15CONNFCT AWG#8 1 3 1 THWN-2 AWG#8 I THWN-2 CU PVC 3/4" 459C 0.95 80 FT 2.02% 0 C O Uj 1 a-3 AC DISCONNECT I MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#8 I THWN-2 CU PVC I" 45QC 0.95 10 FT 0.1 G% 00 G - F N 0 ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 900 V AND 90QC WET ENVIRONMENT. [NEC G90.8(B)(I)): (lec)'(#ofetrin s)'(I.5G) = 1 9.GG A 3-LINE D I A. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY g Modules per String )3 TO, AND LOCATED AS CL05E AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. AWG#12,ampGG A, Temp rerDCate =e size I G A 20.I G A>19.GG A,therefore DC wire size is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 2G COMPLY WITH NEC 1 10.29. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 39.33 A - Record low temp -I OQC FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACE550KIE5 TO FULFILL AWG#8, ampacity'(Temp Derate)'(Conduit Fill Derate) = 52.25 A Voc Temp Coefficient -0.24016/9C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 52.25 A>39.33 A, therefore AC wire size is valid. DC SYSTEM 5PECIFICATION5 G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. Inverter Max Amperage output' (1.25) = 39.33 A Operatinq Current 10.8 A N .T.5. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G,ampacity'(femp Derate)'(Conduit Fill Derate)= 71.25 A Operatmoj Volta6je 37.4 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A> 39.33 A, therefore AC wire size is valid. Max. System Voltage 49.G V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEED LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR ILSCO GBL-4D5T LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS I5(positive/negative) Max AC Output Current 39.33 A PV-5 OR O eratin AC Volta e 940 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 10000 15000200003000 Zoho Sign Document ID:2A768FFA-MOCYFL5H8M1SGW2CMLHYSCTXQXCYS5PIZA7YQTKVLTY SERVICE METER OI O I� __ INSTALLATION NOTE DESIGN E DRAFTING BY: ELEMENT ENERGY LLC SO 4 REVIEW BY J.M.NABCEP CERTIFIE LAR PV SYSTEM � PHOTOVOLTAIC � • • •Small ( I ) ALL LABEL SHALL BE INSTALLED IN 05 1 1 1 2-1 29 EQUIPPED 1NITN I SOLAR BREAKER � •• ACCORDANCE WITH THE 2017 NEC RAP1D SHUTDOiNN ® •• • REQUIREMENTS. RevlsloNs •• DE5CRIFTION DATE REV (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 0804-2023 MAX SYSTEM VOLTAGE VDC SOLAR AC LOAD CENTER- OUTSIDE 4 DO NOT RELOCATE THIS SHO REQUIRE FIELD VERIFICATION. sOVERCURRENT DEVICE ` 1 (3) LABELS, WARNING(S) AND MARKING O3 TURN RAPID SHUTDOWN SWITCH TO Og SHALL BE IN ACCORDANCE WITH NEC THE'OFF POSITION TO SHUTDOWN _ 1 10.2 I (B). SHOCK HAZARD IN THE ARRAY - { PV SYSTEM AND REDUCE cAunoN INIM AC DISCONNECT ` FROM THE LLOMNS�� (4) THE MATERIAL USED FOR MARKING -- --- DISCONNECTS LOCATED ASSHOYM MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER- INSIDE O ® IN THE ' IV � COMPLIANCE WITH NEC 110.2 I (B)(3). CONTRACTOR BREAXEwR/ I ELEMENT ENERGY, LLC. ® 0 ® 1 1 ® - .I� wY (5) THE PV SYSTEM CIRCUIT CONDUCTORS 7470 SOUND AVE '� ® SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 195 THIS EQUIPMENT FED BYMULMPLE DUAL SOU POWER SUPPLY SOURCES.TOTAL RATINGOFALL COMPLIANCE WITH NEC G90.3 1 . LICENSE # G74G I-HI OVERCURRENT DEVICES,EXCLUDING RCES:UTILITY GRID LICENSE # 52689-ME MAIN SUPPLY OVERCURRENT I AND PVSOLAR DEVICE,SHALL NUT EXCEED ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING N ACRYOFBUSBAR - I C�oF NEw O THIS SERVICE METER _ IS ALSO SERVED BY A 0 r ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM , trti I COMBINER PANEL PHOTOVOLTAIC SYSTEM Z 2 I TERMINALS ON THE LINE AND N� Z"Ya `C9 LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS O 7034 43 !V CONDUIT - OUTSIDE BUILDING I —IN THE OPEN POSITION --------------- AR�FESStoNP�. - PROJECT NAME U- U D7POWERSUPP7,'�' wLLJ SO GRID ' WFV IC SYSQ MAIN SERVICE PANEL - OUTSIDE O 1 cLnn — — 5 11�AUTK3�i S C3RCUIT W Z >-- � � CZ LLJ w z SOLAR ELECTRIC SYSTEM CONNECTED p O � ( — © PHOTOVOLTAIC SYSTEM O < O lZ AC • O — E/: MAIN SERVICE PANEL — INSIDE ,p� '• " N Q OPERATING VOLTAGEVOLTS POWER SOURCE Ip OUTPUT CONNECTION 1 ® O I DO NOT RELOCATE THIS I SHEET NAME OV_ERCUR_RENT DEVICE_'; LABELS AC DISCONNECT/BREAKER DRAWING SCALE 000 ® ® N .T.S. SHEET NUMBER PV-6 TAX MAP: 100001 5000200003000 ENPHASE. IQ8 and I +- Microinverters Ealsy'toirl;stat! Our newest IQS Microinverters are the industry'sfirst microgrid-forrning,software- Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug=n-plays connectors power to AC power efficiently.The brain of-the semiconductor-based;microinverter Power$�ss:&r1€srlscatioiF is our proprietary application-specific integrated circuit(ASIC)lwhiclt enables the MC?,beteal;codreporlsnts microinverter to operate in grid-tied or off-grid;modes..This'chip,isbuilt liradvanced 55nm technology with high speed digital logic:and has super.-fast responseVirnes Faster installation:with simpre to changing loads and grid events,atreviating con-straieii son!batter} skiing forhome two-Ate cablilg, . energy systems. &-xffi prodtscKv f p ands rer&ibHity Produce Rosser even,wherr the 3 grid is down* i ' i-- Morethan one:rrlillioncumulative hoursoftestlitg di Crass Ili double-insulate Part of the Enphase Energy System,108'Series 108 Series hliicroinverters,redefine reliability eilelbsure Microinverters;verte integrate with the Enphase 10 EL-attery, standards with more than�one miNien cumulative - Qpf{ i22E fDr' r3feS�Fii EnIS IMF phase 10 10 Gateway,and the Enphase App monitoring hours ofpower-on testing,enabling an industry- and analysis software. leading limited warranty of up to25 years. powsied PV modules lUi'rb6+og ' • ' „ E:cFmplie3uulttttfte�l'a#est advariced gate support- CERTIFIED • Remote automatic updates for the latest:grid requirements Connect PV modules quickly and easily to 108 Series 108 Series NUcroinverters are UL Listed as Configurable to support a wide Microinverters using the included O-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. . Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,108 Microinverters,and other •Only when installed with 10 System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. '•108 and 108PIus supports split phase,240V 108SP-DS-0002-01-EN-US-2022-03-17 installations only. I08 and IQ8+ Microinverters INPUT 1ATA(OCI 108-60-2-US' Commonly used module pairings' W 235-350 235-440 Module compatibility _ 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 - 29-45 Operating range v 25-48 25-58 Min/max start voltage v 30/48 30/58 Max input DC voltage v 50 60 Max DC current'[module[so] A 15 Overvoltage class DC port II DC port backfeed current MA :0- PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit 1 1198 ,1 Peak output power VA 245 " J. 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' v 240/211-264 Max continuous output current y _ ____ _ _ __J.0- 1.21 Nominal frequency Hz - 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per.20-A(L-L)-branch_circuir_-__ __ 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85leading-0.85lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08k4(2:381bs) Cooling Natural convection-no fans Approved for wet Idcatibns Pollution degree PD3 Enclosure Class II double-insulated,coProsion'resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C222 NO.1071=01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and OC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 108SP-OS-0002-01-EN-US-2022-03-17 powered by - �+ on 2 21 :; Was�antyv ®CELLS PromaNO- yield SecLrity a BREAKINGTHE 20%EFFICIENCY BARRIER nn/Il llllnllll�III Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.0%. TH'EMOSTTHOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new`Quality Controlled PV"of i the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH,PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID TechncicV,Hot-Spot Protect and Traceable Quality Tra.GTm. EXTREMEWEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). 1 [� A RELIABLE INVESTMENT V?� Inclusive 25-year product warranty and 25-year linear performance warrantyz. 'APT test conditions according to IEC/TS 62804-1:2015,method A(-1500 V,96h) ]See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings Engineered in Germany (mm%^ C E L L MECHANICAL SPECIFICATION ac 74.Oin x 41.1in x 1.26in(including frame) (1879 mm x 1045 mm x 32mm) --- '°'0 I's'9mml uer3sa5mm) az a IweaRm) ;yr,< 48.5lbs(22.Okg) -c':sr 0.13in(3.2mm)thermally pre-stressed glass with 1 anti-reflection technology _--_- 4 o�m9P °ae•lasmm) rmm° Composite film2 a- Black anadizedaluminum T. .e 4LrU�­) 6 x 22 monocrystalline Q.ANTUM solar half cells r^;)fin 3::�^< 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes L�� 4v2 u2s°mm) _ I Cade 4mm2 Solar cable;(+)>49.2in(1250mm),(-)>-49.2in(1250mm) 4,Mouregd9 JMrNLA) - Steubli MC4;IP68 1 -{�-�aa•13P mm) ceIn as5•ueRm) 036'g45mm) �I�I�mm) I --- ELECTRICAL CHARACTERISTICS POWER CLASS - 385 390 395 400 405 a;h.ri#t._�+i=-, =�i'>.j,i i.,`-- _ ..-; -->>_ ..'i� a'� �=tii'.�^ .._�i'a"�:`•f�c ,`�`!:-`:•t9/j pMPP [W] 385 390 395 40C _ 40C Ise --- [A] 11.04 11.07 11.10 11.14 -- - 11.17 Vcc - [V] 45.19 45.23 45.27 45.30 - 45.34 at Vt?p IMPP [A) 10.59 10.65 10.71 10.77 10.83 VMPP IV] -- 36.36 36.62 36.88 37.13 --_ 37.39 >19.6 >:19.9 >20.1 -eKA ?20.6 -.`•,Y'.r -_ ----_ .-..-.- .._.-.0� at'++) .^. .....--- ...-..-� PMPP.__.-....-.IWI._...- --.. 288.8�-.._. 292.6 296.3 300.1 303.8 Isc IA]--- 8.90 8.92 8.95 8.97 9.00 Voc [Vl 42.62 42.65 42.69 42.72 42.76 C.;=s^.t_s l.)9� MPP-- [A] ----- 8.35 8.41 8.46 8.51 _ 8.57- VMPP _ IV] - 34.,99 - 34.81 - 35.03 35.25 - 35.46 Measurement tdleiances P_33%;I,,;Vcc 35%at STC 1GCC W/m',25 t2°C,AM 1.5 according to IEC 6139C4-3•'8CC WJm2,NMOT,spectrum AM 15 ®CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE cc���b At least 98%of nominal power during ss° -- i z` first year.Thereafter max.0.5% =• ' .. degradation per year.At least 93.5% m° of nominal power up to 10 years.At , least 86%of nominal power up to y ' -- _ a All data within measurement toleranc- es.Full warranties in accordance with m° o' the warranty terms of the Q CELLS ,,c,.,,,_cs,,,rr sales organisation of your respective o e m m m m country. Typical module performance under low irradiance conditions in ccmpariscotoSTC conditions(26°C,1000WJm2) m TEMPERATURE COEFFICIENTS c; _ t reC=erf#c'a z;i!;c a [%/K] +0.04 raz,stursCus'rrc;e'co _r:c p 1%/K] -0.27 _C FrP Y [%/K] -0.34 >:oml+.aI:a,io +#e CC-,reirg 7a;,noa;.r,::e NMOT [°F] 109±5.4(43±3°C) s. erec+_r_ ccaicis•::cm o PROPERTIES FOR SYSTEM DESIGN a ,t;la.dmum Systarn VOR-3-ia V;, [VI 1000(IEC)/1000(UL) ?V inadula Class II o W ;lAs:61.1um Ss:las usa Rating [A DC] 20 Fire.r;a-ir.;basal on:a,'SI!L'_517,:10 TYPE 2 all 2 r a;-ik"Sf1NIot#;i-i arripa,aturS -40'Fupto+185°F c dax.0sagr,Lcaa;PL:s�.J=u,; [Ibs/ft] 75(3600Pa)/55(2660Pa) an Ccr.1iruoas Duty (-40°C up to+85°C) i;iax.Tes2Laac,Ausn/gull° pbs/ft2] 113(5400Pa)/84(4000Pa) m m 'See Installation Manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m UL 61730,CE-compliant, 5 -aft Ouafity Controlled PV-7UV Rheinland, 4VHC �� m s�® C E -s 2 IEC 61215:2016,IEC 617302016, U.S.Patent Na.9,893,215(solar coils), lwaneaa�° � �-'=C.i.91 76.4 in 43.3 in 48.0 in 16561bs 24 24 32 OCPV CertHicaticn ongoing. Cc�,ma Ug 1940mm 1100mm 1220mm 751kg pallets pallets _modules 1. UL ft= ......wv.mm `_. m m 1112xvm o. m Note:Installation instructions must be followed.Seethe installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Han%vha 0 CELLS America Inc. 4130 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 961 EMAI L inquiry@us.q-cells.com I W ES www.q-cells.us . IRONRIDGE Flush Mount System Wt y^� Built for solar's 'tougliest roofs. IronPidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior P Pre-stamped engineering letters structural performance. available in most states. C9ass A Fare Rating Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. XR Rails ' XR10 Raii ff XR100 Rail XR1000 Rail Banded Splices A low-profile mounting rail'F The ultimate residential I fJ A heavyweight mounting All rails use internal splices for regions with light snow.'? solar mounting rail. rail for commercial projects. for seamless connections. * 6'spanning capability m A'spanning capabilibi - 12'spanning capability - Self-drilling screws ";oad capability . Varying versions for rails * Moderate load capability Heavy load capability - Extreme load capability Clear c f Forms secure bonding * Clear and black finish lear and black finish - Clear anodized finish Clamps & Grounding ii, UFOs Stopper Sleeves Grounding Lugs Miciroinverteir Kits 14�_ 77.4 Universal Fastening Objects Snap onto the UFO to turn Y-S to. Mount lulls or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled& lubed Bonds modules to rails - Low profile - Bonds devices to rails • Single, universal size a Sized to match modules - Singie tooi installation - Kit comes assembled • Clear and black finish Clear and black finish - Mounts in any direction . Listed to UL 2703 Attachments FRashFool:2 Conduit Mount Slog Bonding Ha7dware OWN\ Flash and mount XR Rails Flas d mount conduit, esign for rapid rail Bond and attach XR Rails with superior waterproofing ut, or junction boxes. attachment. to roof attachments. • Twist-on Cap easesi 11 - Twist-on Cap eases install - Secure rail connections - T&Square Bolt options • Wind-driven rain tested - Wind-driven rain tested ® Slot for vertical adjusting - Nut uses 7/16"socket • Mill and black finish - Secures 3/4"or 1"conduit - Clear and black finish - Assembled and lubricated Resources Design Assistant NABCEP Certified Training 4 Co from rough layout to fully Earn free continuing education credits, engineered system. For free. while learning more about our systems Go to IronRidge ccrn/design Go o lronRidge,corr, trainirig