Loading...
HomeMy WebLinkAbout50496-Z t TOWN OF SOUTHOLD " BUILDING DEPARTMENT rw k TOWN CLERK'S OFFICE -° SOUTHOLD, NY ` BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50496 Date: 4/1/2024_____._ Permission is hereby granted to: Theodosopoulos, Nikos .... _m_ _..... -._ _ . .. 175 Aldershot Ln Manhasset, NY 11030 To Demolish existing dwelling and construct a new two story single-family dwelling with deck and pool additions, unfinished basement and HVAC system as applied for per DEC and SCHD approvals. Pool equipment must maintain a minimum side and rear yard setback of 10 feet. At premises located at: 595 N Parish Dr Southold SCTM # 473889 Sec/Block/Lot# 71.-1-6 Pursuant to application dated 2/26/2024 and approved by the Building Inspector. p /2025.To expire on ....... 10 1 e Fees: DEMOLITION $840.00 SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $2,629.00 SWIMMING POOLS - IN-GROUND WITH FENCE ENCLOSURE $300.00 CO - RESIDENTIAL $100.00 Total: $3,869.00 Building Inspector era"' r TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971 0959 �r Telephone (631) 765-1802 Fax (631) 765-9502 lilt S:rl �a, otzRll o-1 lto r�l y t Y. Date Received APPLICATION FOR BUILDING PERMIT ' For Office Use Only w PERMIT NO, Building InsErectc��rF, V. 'K211 IN Ap�tIF tons and farms must be filled out in their entirety;Incomplete lm r r Owner's I#u�haratior�f4 (Pale 2 shalt#te A�piilcant! n o ot the. vurrer,an applicatlor wy.,not be atce ted. ,Where I'he completed. Date: I/AP/24 iC 441TY Name: i�r � V�0 "/ SCTM # 1000- .. o . Project Address: 5q5 N 6j(15S1 D r i ve, 5oofhOiCI' � Phone#: 014) 35 - 0926 Email: Yl#Ko3 1,0 (Y)o II . C OM Mailing Address: j75 Alc<le'r3ho-1- ; l' i � � t Name: M arick M ck4 eiS Mailing Address: q(0Cl 'AIldW1n Tof hr l�r P0.()VI -1t 42cl Phone#: Email; e(Ml 5 eolKarckN of 5i ).C �► n �AT � Name. Mailing Address: PO 'Box 250 Vqpk1Qr)K, N ° i19,1 't . Phone#: *1n X-'SSi. r LcfkUrch .5, cc Name: TOD Mailing Address: Phone#: Email: ��I l ItI "� '` MNiS"T'Ru� ION ,. %New Structure ❑Addition ❑Alteration ❑Repair. Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded?XYes ❑No Will excess fill be removed from premises? ❑Yes o 1 PROPERTY 1NFORMAT116" Existing use of property:, a 'den-W) Intended use of property: 2_s4ory I-Fomdy doel,6 Zone or use district in which premises is situated Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY C 6G7(AftC R ;dln�:,The o�arrer/contra tar/design professlgnal is respansfble fpr all„rlreinag�gnd st$rm water issue h Buildi` Ce artment far th®issuance of„a 6ufldin Per pu }t rst '/ f%f, "!Ike T23 rfi,'si,3 'rtC9d#,APpLlfA1UN,iSHEtE BY,MACiEtote !fig p ,,, '' o N ordinances or ft ulafions f Frw riai ce aft 7�wn Q��auth ld Suffa� ;,County, Aw York and vs, ,; or t to carysir�rt�ar►'of�+�m s %///%'; ad,drtr6°ris >a�lin� tir}ns ter}off remove4 or dematition es herein descritsed The applieantagrges to comply with all applK able laws,arslirfa� ,bul r je j/ �itf�i iryg ar de`afi regtr hs�fa grid tc admit eutiharrzed s+is t?rtars c��r piarrxises,and`in huildin$(s}for,necdssery in�pecfiirns.Felse stater ntS maw l��{�n a p n sffa�ife as a Class A misdemeanor pursuant tc Sectilon OAS,of the,< ew Volk State Penal Law.' / Application Submitted By(print name): MCL.rI CA MQ{{ Authorized Agent ❑Owner Signature of Applicant: -Alvw Date: 1/2f/24 STATE OF NEW YORK) LUCILLIE DIMARIA SS: Notary Public,state of New York No.41-4Z -1807" COUNTY OF ) Oualilied In Queens County Cotnmrmission Expires June 30, 0 Li y"a ' al eu being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the l 114 (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Y ,a day of 1), 40U421� i° 20 1 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) K� �� � .0� residing at pr .c 1, �a� do hereby authorize to apply on 2s1 Ij 7jato Town outhold Building Department for approval as described herein. 2-� zo Z� Owne "s gnature '"' Date Print Owner's Nam 2 BUILDING DEPARTMENT- Electrical Inspector dig TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 mw Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh southoldtownn . dv seand southoldtownr� . ov ;a APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2/6/2024 Company Name. TBD (electrician to be picked before construction) Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (Ail Information Required) Name: Nikos Theodosopoulos Address: 595 North Parish Drive Cross Street: North Bayview Road Phone No.: 917-359-0825 Bldg.Permit#: 5TC email: nikostl @gmail.com Tax Map District: 1000 Section: 71 Block: 1 Lot: 06 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Disconnect electrical service from the existing house and move to a H frame system. The existing house will be demolished. Square Footage: Circle All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate?: El YES NO Issued On Temp Information: (All information required) Service Size1 Ph 3 Ph Size: A # Meters Old Meter# ❑New service[—]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D1 D2 H Frame Pole Work done on Service? Y N Additional Information: TBD (electrician to be picked before construction) PAYMENT DUE WITH APPLICATION Buildinp-Devartment Application AUTHORIZATION (Where the Applicant is not the Owner) T�e4cr>o 0 L/ siding_N_l 5 re at (Print proper(3r owner's came (Moiling Address) Y1 do hereby authorize (Agent) CA, U rT 4?>t to apply on my behalf to the Southold Building Department. wner's Signature) (Date) S (Print Owner's Name) 2 It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction and Coastal Erosion Hazard Area, which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and the coastal erosion hazard area and your project or erecting a temporary fence, barrier, or hay bale berm. This determination is not a determination from any other agency. If you have any further questions, please do not hesitate to call. Sincerely, 4-P Glenn Goldsmith, President Board of Trustees GG:dd Glenn Goldsmith President �� o� �� Town Hall Annex m W o 54375 Route 25 A.Nicholas Krupski,Vice President `^ P.O.Box 1179 Eric Sepenoski � J �r Southold,New York 11971 Liz Gillooly i Telephone(631)765-1892 Elizabeth Peeples oilfl 631 Fax � ( ) 7 65-6641 °a % BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD March 2, 2023 Robert W. Anderson Suffolk Environmental Consulting, Inc. P.O. Box 2003 Bridgehampton, NY 11932-2003 RE: NIKOS THEODOSOPOULOS 595 NORTH PARISH DRIVE, SOUTHOLD SCTM#: 1000 71-1-6 Dear Mr. Anderson: The Southold Town Board of Trustees reviewed your letter received in this office on January 27, 2023, and the survey prepared by Kenneth M. Woychuk Land Surveying, PLLC, last dated October 20, 2022, and determined that the demolition of existing dwelling and proposed construction of two (2) story single family dwelling with seaward deck and swimming pool are out of the Wetland jurisdiction under Chapter 275 of the Town Wetland Code and Chapter 111 of the Town Code. The existing gazebo Is,within Trustee 'urisdiction, If gazebo is ifled a Thu ee errnit will be r d. Therefore, in accordance with the current Wetlands Code (Chapter 275)_and the Coastal Erosion Hazard Area (Chapter 111) no permit is required. Please be advised, however,that no clearing, no removal of vegetation, no cut or fill of land or removal of sod, no construction, sedimentation, or disturbance of any kind may take place within 100' landward from the top of the bluff, or seaward of the tidal and/or freshwater wetlands jurisdictional boundary or seaward of the coastal erosion hazard area as indicated above, without further application to, and written authorization from, the Southold Town Board of Trustees pursuant to Chapter 275 and/or Chapter 111 of the Town Code. NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Division of Environmental Permits,Region 1 SUNY @ Stony Brook,50 Circle Road,Stony Brook,NY 11790 P:(631)444-03651 F:(631)444-0360 www.clec.ny.gov February 14t", 2023 Nikos Theodosopoulos 175 Aldershot Ln Manhasset, NY 11030 Re: Permit No. 1-4738-00331/00006 Theodosopoulos Property — 595 N Parish Dr., Southold, NY 11971 SCTM # 1000-71-1-6 Dear Permittee: In conformance with the requirements of the State Uniform Procedures Act (Article 70, ECL) and its implementing regulations (6NYCRR, Part 621) we are enclosing your permit for the referenced activity. Please carefully read all permit conditions and special permit conditions contained in the permit to ensure compliance during the term of the permit. If you are unable to comply with any conditions, please contact us at the above address. Enclosed is a permit sign which is to be conspicuously posted at the project site and protected from the weather and a Notice of Commencement/Completion of Construction. Sincerely, Danielle Stango-Torre Environmental Analyst NF. YONI< Depertrnetrtof ra ro Environmental Conservatlon NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Facility DEC ID 1-4738-00331 PERMIT Under the Environmental Conservation Law JCL E�--. .............----... ...... Permittee and Facility Information Permit Issued To: Facility: NIKOSTHEODOSOPOULOS THEODOSOPOULOSPROPERTY 175 ALDERSHOT LN 595 N PARISH DRISCTM1000-71-1-6 MANHASSET,NY 11030 SOUTHOLD,NY 11971 Facility Application Contact: SUFFOLK ENVIRONMENTAL CONSULTING INC PO BOX 2003 BRIDGEHAMPTON,NY 11932-2003 (631) 537-5160 Facility Location: in SOUTHOLD in SUFFOLK COUNTY Facility Principal Reference Point: NYTM-E: 717.566 NYTM-N: 4547.657 Latitude: 41°03'03.9" Longitude: 72°24'40.2" Authorized Activity: Construct a single family dwelling, driveway,pool with deck. Install I/A OWTS. All work shall be done in struct conformance with the attached plans prepared by Kenneth M Woychuk Land Surveying, last revised 10/20/2022 and stamped NYSDEC approved on 2/13/2023. Permit Authorizations Tidal Wetlands -Under Article 25 Permit ID 1-4738-00331/00006 New Permit Effective Date: 2/13/2023 Expiration Date: 2/12/2028 NYSDEC Approval By acceptance of this permit, the permittee agrees that the permit is contingent upon strict compliance with the ECL, all applicable regulations,and all conditions included as part of this permit. Permit Administrator: SHERRI L AICHER, Deputy Permit Administrator Address: NYSDEC Region 1 Headquarters SUNY @ Stony BrookJ50 Circle Rd Stony Br k,NY 11790 -3409 Authorized Signature: .�� Date z/ 3 /Z6 Z3 Page 1 of 6 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Facility DEC ID 1-4738-00331 Distribution List SUFFOLK ENVIRONMENTAL CONSULTING INC Bureau of Marine Habitat Protection DANIELLE A STANGO-TORRE Permit Components NATURAL RESOURCE PERMIT CONDITIONS GENERAL CONDITIONS, APPLY TO ALL AUTHORIZED PERMITS NOTIFICATION OF OTHER PERMITTEE OBLIGATIONS NATURAL RESOURCE PERMIT CONDITIONS - Apply to the Following Permits: TIDAL WETLANDS 1. Conformance With Plans All activities authorized by this permit must be in strict conformance with the approved plans submitted by the applicant or applicant's agent as part of the permit application. Such approved plans were prepared by Kenneth M Woychuk Land Surveying, last revised 10/20/2022 and stamped NYSDEC approved on 2/13/2023. 2. Prohibition Period for Nesting Birds To protect nesting shorebirds, including threatened and/or endangered species, no regulated activities may occur between April 1 and August 31, inclusive, of any calendar year. 3. Concrete Leachate During construction, no wet or fresh concrete or leachate shall be allowed to escape into any wetlands or waters of New York State,nor shall washings from ready-mixed concrete trucks, mixers, or other devices be allowed to enter any wetland or waters. Only watertight or waterproof forms shall be used. Wet concrete shall not be poured to displace water within the forms. 4. No Construction Debris in Wetland or Adjacent Area Any debris or excess material from construction of this project shall be completely removed from the adjacent area(upland)and removed to an approved upland area for disposal. No debris is permitted in wetlands and/or protected buffer areas. 5. No Disturbance to Vegetated Tidal Wetlands There shall be no disturbance to vegetated tidal wetlands or protected buffer areas as a result of the permitted activities. 6. Seeding Disturbed Areas All areas of soil disturbance resulting from the approved project shall be stabilized with appropriate vegetation(grasses, etc.) immediately following project completion or prior to permit expiration,whichever comes first. If the project site remains inactive for more than 48 hours or planting is impractical due to the season,then the area shall be stabilized with straw or hay mulch or jute matting until weather conditions favor germination. Page 2 of 6 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Facility DEC ID 1-4738-00331 7. Storage of Equipment,Materials The storage of construction equipment and materials shall be confined within the project work area and/or upland areas greater than 75 linear feet from the tidal wetland boundary. 8. Contain Exposed, Stockpiled Soils All disturbed areas where soil will be temporarily exposed or stockpiled for longer than 48 hours shall be contained by a continuous line of staked haybales/silt curtains (or other NYSDEC approved devices)placed on the seaward side between the fill and the wetland or protected buffer area. Tarps are authorized to supplement these approved methods. 9. Temporary Mulch,Final Seeding If seeding is impracticable due to the time oryear, a temporary mulch shall be applied and final seeding shall be performed at the earliest opportunity when weather conditions favor germination and growth but not more than six months after project completion. 10. Maintain Erosion Controls All erosion control devices shall be maintained in good and functional condition until the project has been completed and the area has been stabilized. 11. Clean Fill Only All fill shall consist of clean sand, gravel, or soil (not asphalt, slag, flyash, broken concrete or demolition debris). 12. Department Jurisdiction The department retains jurisdiction of all regulated lands where rill has been permitted. Placement of fill shall not be used to alter the department's Tidal Wetland jurisdictional area at the project site. The area remains a regulated area subject to Tidal Wetland Land Use restrictions of 6 NYCRR Part 661. 13. Straw Bales or Other at Tidal Wetland A row of staked straw bales or approvable erosion control devices shall be placed at the landward edge of the buffer area or 75 linear feet from the tidal wetland boundary,or as per the NYSDEC-approved plan,prior to commencement of any regulated activities and remain in place and in good, functional condition until the project is completed and all disturbed areas are stabilized with vegetation. 14. Install,Maintain Erosion Controls Necessary erosion control measures, i.e., straw bales, silt fencing, etc., are to be placed on the downslope edge of any disturbed area. This sediment barrier is to be put in place before any disturbance of the ground occurs and is to be maintained in good and functional condition until thick vegetative cover is established. 15. Runoff Directed to Upland Drywells Roof runoff shall be directed to drywells a minimum of 100 linear feet landward of the tidal wetland boundary for immediate on-site recharge. 16. No Drywells in or near Wetland Dry wells for pool filter backwash shall be located a minimum of 100 linear feet landward of the tidal wetland boundary. 17. No Pool Discharges to Wetland There shall be no draining of swimming pool water directly or indirectly into wetlands or protected buffer areas. 18. Driveway/Parking Area of Pervious Material Driveway and parking areas shall be constructed of NYSDEC-approved pervious materials. Page 3 of 6 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Facility DEC ID 1-4738-00331 19. Authorized Innovative/Alternative Onsite Wastewater Treatment Systems (I/A OWTS) Septic Systems This permit authorizes the installation of any models of I/A OWTS septic system which have received the approval of the Suffolk County Department of Health Services(SCDHS). If SCDHS rescinds its approval of one or more of these models during the term of this permit,DEC will no longer approve new installations of that model. The list of I/A OWTS systems which have received approval by SCDHS are found on the Suffolk County Website under the Reclaim Our Water-Homeowner section at: Overview of Provisionally Approved Technologies. 20. Maintenance of Installed Innovative/Alternative Onsite Wastewater Treatment Systems (I/A OWTS) The permittee must maintain, service and repair the installed I/A OWTS in accordance with the maintenance schedule set forth in the Suffolk County Department of Health Services (SCDHS) permit issued for the system. 21. Notice of Commencement At least 48 hours prior to commencement of the project,the permittee and contractor shall sign and return the top portion of the enclosed notification form certifying that they are fully aware of and understand all terms and conditions of this permit. Within 30 days of completion of project, the bottom portion of the form must also be signed and returned, along with photographs of the completed work. 22. State Not Liable for Damage The State of New York shall in no case be liable for any damage or injury to the structure or work herein authorized which may be caused by or result from future operations undertaken by the State for the conservation or improvement of navigation, or for other purposes, and no claim or right to compensation shall accrue from any such damage. 23. State May Order Removal or Alteration of Work If future operations by the State of New York require an alteration in the position of the structure or work herein authorized, or if, in the opinion of the Department of Environmental Conservation it shall cause unreasonable obstruction to the free navigation of said waters or flood flows or endanger the health, safety or welfare of the people of the State, or cause loss or destruction of the natural resources of the State,the owner may be ordered by the Department to remove or alter the structural work, obstructions, or hazards caused thereby without expense to the State, and if,upon the expiration or revocation of this permit,the structure, fill, excavation, or other modification of the watercourse hereby authorized shall not be completed,the owners, shall, without expense to the State, and to such extent and in such time and manner as the Department of Environmental Conservation may require,remove all or any portion of the uncompleted structure or fill and restore to its former condition the navigable and flood capacity of the watercourse. No claim shall be made against the State of New York on account of any such removal or alteration. 24. Precautions Against Contamination of Waters All necessary precautions shall be taken to preclude contamination of any wetland or waterway by suspended solids, sediments, fuels, solvents, lubricants, epoxy coatings,paints, concrete, leachate or any other environmentally deleterious materials associated with the project. 25. State May Require Site Restoration If upon the expiration or revocation of this permit, the project hereby authorized has not been completed,the applicant shall, without expense to the State, and to such extent and in such time and manner as the Department of Environmental Conservation may lawfully require, remove all or any portion of the uncompleted structure or fill and restore the site to its former condition. No claim shall be made against the State of New York on account of any such removal or alteration. Page 4 of 6 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Facility DEC ID 1-4738-00331 GENERAL CONDITIONS - A 1 to AL _. _ ��pp y L Authorized Permits: 1. Facility Inspection by The Department The permitted site or facility, including relevant records, is subject to inspection at reasonable hours and intervals by an authorized representative of the Department of Environmental Conservation (the Department)to determine whether the permittee is complying with this permit and the ECL. Such representative may order the work suspended pursuant to ECL 71- 0301 and SAPA 401(3). The permittee shall provide a person to accompany the Department's representative during an inspection to the permit area when requested by the Department. A copy of this permit, including all referenced maps, drawings and special conditions,must be available for inspection by the Department at all times at the project site or facility. Failure to produce a copy of the permit upon request by a Department representative is a violation of this permit. 2. Relationship of this Permit to Other Department Orders and Determinations Unless expressly provided for by the Department, issuance of this permit does not modify, supersede or rescind any order or determination previously issued by the Department or any of the terms, conditions or requirements contained in such order or determination. 3. Applications For Permit Renewals,Modifications or Transfers The permittee must submit a separate written application to the Department for permit renewal, modification or transfer of this permit. Such application must include any forms or supplemental information the Department requires. Any renewal, modification or transfer granted by the Department must be in writing. Submission of applications for permit renewal, modification or transfer are to be submitted to: Regional Permit Administrator NYSDEC Region 1 Headquarters SUNY @ Stony BrookJ50 Circle Rd Stony Brook,NY11790 -3409 4. Submission of Renewal Application The permittee must submit a renewal application at least 30 days before permit expiration for the following permit authorizations: Tidal Wetlands. 5. Permit Modifications, Suspensions and Revocations by the Department The Department reserves the right to exercise all available authority to modify, suspend or revoke this permit. The grounds for modification, suspension or revocation include: a. materially false or inaccurate statements in the permit application or supporting papers; b. failure by the permittee to comply with any terms or conditions of the permit; c. exceeding the scope of the project as described in the permit application; Page 5 of 6 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Facility DEC ID 1-4738-00331 d. newly discovered material information or a material change in environmental conditions, relevant technology or applicable law or regulations since the issuance of the existing permit; e. noncompliance with previously issued permit conditions, orders of the commissioner, any provisions of the Environmental Conservation Law or regulations of the Department related to the permitted activity. 6. Permit Transfer Permits are transferrable unless specifically prohibited by statute,regulation or another permit condition. Applications for permit transfer should be submitted prior to actual transfer of ownership. E- - ---- ...... .............. -------------- ............... NOTIFICATION OF OTHER PERMITTEE OBLIGATIONS Item A: Permittee Accepts Legal Responsibility and Agrees to Indemnification The permittee, excepting state or federal agencies,expressly agrees to indemnify and hold harmless the Department of Environmental Conservation of the State of New York, its representatives, employees, and agents ("DEC")for all claims, suits, actions, and damages,to the extent attributable to the permittee's acts or omissions in connection with the permittee's undertaking of activities in connection with, or operation and maintenance of, the facility or facilities authorized by the permit whether in compliance or not in compliance with the terms and conditions of the permit. This indemnification does not extend to any claims, suits, actions, or damages to the extent attributable to DEC's own negligent or intentional acts or omissions, or to any claims, suits, or actions naming the DEC and arising under Article 78 of the New York Civil Practice Laws and Rules or any citizen suit or civil rights provision under federal or state laws. Item B: Permittee's Contractors to Comply with Permit The permittee is responsible for informing its independent contractors, employees, agents and assigns of their responsibility to comply with this permit, including all special conditions while acting as the permittee's agent with respect to the permitted activities, and such persons shall be subject to the same sanctions for violations of the Environmental Conservation Law as those prescribed for the permittee. Item C: Permittee Responsible for Obtaining Other Required Permits The permittee is responsible for obtaining any other permits, approvals, lands, easements and rights-of- way that may be required to carry out the activities that are authorized by this permit. Item D: No Right to Trespass or Interfere with Riparian Rights This permit does not convey to the permittee any right to trespass upon the lands or interfere with the riparian rights of others in order to perform the permitted work nor does it authorize the impairment of any rights, title, or interest in real or personal property held or vested in a person not a party to the permit. Page 6 of 6 N )� � C cu L E O N O O •C Q a 0 Li (D Ec c� ti v -a LV o o 0 �1 L N r CA `` LL S.L c a) t� •C a) cn +r = L Q V Y Q Cl)= M C 0 0- Q ° Lo ° .N -a ca N cn N 00 .CU a) c: o — U .5c� w inw U o o L.LI v ca Q z m p � � � CL s ... C L C m .— C o (D o ouju �;-';j Y a, co z L L o _ to L O C C O LLOD O N •� .� c H O U (a 'a 0 ~ Q0. J p N L � ' N E cc +, N co N C) C C U L O N > � � 00 N C L C V U CM W 0) C ti +- 44 CUC O +� N cu N E c: N N O O c L ca > C co = � C C W o O �-j z O p cu — cu L- a) 'F"' 0 Q) •Q. r C10 Generated by REScheck-Web Software NJ/ Compliance Certificate Project 595 N Parish Drive Energy Code: 2018 IECC Location: Southold, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 31159 ft2 Glazing Area 19% Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 595 N Parish Drive Nikos Theodosopoulos Southold, NY 11971 917-359-0825 nikostl@gmail.com 9 Compliance: 8.6%Better Than Code Maximum UA: 602 Your UA: 550 Maximum SHGC: 0.40 Your SHGC: 0.30 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. S�aa alb Non-grade tradeoffs are nolongemr considered in the UA or performance coirnp>iance path in RF.Scheck, Each slab-min-grade in the specified c.. mate zone must meet the nmim irnuirn energy code umu.su atl'on R.value and depd-° requirements, Ennveloae Assemblies, Ceiling-Hot Roof: Cathedral Ceiling 2,413 38.0 0.0 0.027 0.026 65 63 Wall- Partition: Wood Frame, 16" o.c. 330 21.0 0.0 0.057 0.060 18 19 Door: Solid Door(under 50% glazing) 21 0.140 0.320 3 7 Wall: Wood Frame, 16" o.c. 3,464 21.0 0.0 0.057 0.060 157 165 Doors: Solid Door(under 50%glazing) 21 0.140 0.320 3 7 Door 1: Glass Door(over 50%glazing) 282 SHGC: 0.30 0.300 0.320 85 90 Window:Vinyl Frame SHGC: 0.30 412 0.300 0.320 124 132 Floor over Garage: All-Wood joist/Truss 349 30.0 0.0 0.033 0.047 12 16 Floor-Cant:All-Wood joist/Truss 37 30.0 0.0 0.033 0.047 1 2 Basement Wall: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' 1,632 0.0 14.0 0.048 0.059 77 95 Insulation depth: 8.0' Window:Vinyl Frame SHGC: 0.30 18 0.300 0.320 5 6 Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 1 of10 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Gerson Rubio, P.E. 2/15/2024 Name-Title Signature Date Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 2 of10 e p REScheck Software Version ■ Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified Pre-Inspection/Plan R v ew Com liesd Comments/Assumptions # e i Value Value P 103.1, Construction drawings and � _ Oorrmplies _ Requirement �will be met. 103.2 documentation demonstrate []Does Not [PR1]1 energy code compliance for the :building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and EIComplies Requirement will be met. 103.2, documentation demonstrate ❑Does Not. 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is, Heating:.... Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 I�igih Impact(Tier 1) 72 Medium Impact(Tier 2) 3 Low Impart(Tier 3) Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 3 of10 Section Plans Verified Field Verified Foundation Inspection Value Complies? Comments/Assumptions & Re ID _PI Value # F [FO4] 1 Conditioned basement R- R- ❑Does Not _. n R- alue Where ilntenor R R- ❑Com lies table foee thealues. 1 Envelope Assemblies k insulation is used, verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies Requirement will be met. [FO5]1 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable __ wu ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies Requirement will be met. [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies Requirement will be met. [FO12]2 controls installed. 0Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) �:J2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 4 of10 5eetion _..._ —�..,-� --- g g Inspection Plans Verified Field Verified Complies? Comments/Assumptions tions & Re ID Value Value p p # Framing/ Rough-in In M1 .v Urn ❑Com lies See the Envelope 402.1.1, Door U-factor, p Assemblies U- 402.3.4 table for values. (FR1]1 ❑Does Not :y ❑Not Observable -- .... ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average).402.3.3, El Not table for values. 402.5 ❑Not Observable [FR2]1 ❑Not Applicable 303.1.3 U-factors of fenestration products ❑Complies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable �- - -,[:]Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Com [FR23]1 installed per manufacturer's IJCplies Requirement will be met. omoes Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Compl'ies Requirement will be met, [FR20]1 is listed and labeled as meeting ❑Does Not n AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. -- -R---402.4.5 IC-rated recessed lighting fixtures ❑Crampl) s Requirement will be met. [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate s2.0 cfm leakage at 75 Pa. ❑Not Observable m-- .—.- ❑Not Applicable 403.3 1 Supply and return ducts in attics —Exception: Ducts located [FR1211 insulated >= R-8 where duct is ❑I]oe Not completely inside the >= 3 inches in diameter and >=R-6 where < 3 inches. Supply and ❑Not Observable building envelope. return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.2 Ducts, air handlers and filter ❑Complies Requirement will be met. [FR13]1 boxes are sealed with ❑Does Not joints/seams compliant with International Mechanical Code or ❑Not Observable International Residential Code, as ❑Not Applicable _...�._.applicable. 403.3.3 Building cavities are not used as ❑Coomplies Requirement will be met. [FR15] ducts or plenums. Does Not z ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Im act(Tie Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 5 of10 Plans Verified Field Verified Section # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions & Re�.ID [FR28] :conditioned. .p. .,. ._ .. ..._ .. .. _.. w ,� ..... �.� -- ��� 403.3.7 Ducts declared to be within the ❑Complies Requirement will be met. a space are either 1) ❑Does Not V completely within the continuous air barrier and within the building [:]Not Observable thermal envelope, 2) buried ❑Not Applicable within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <= 1.5 cfm/100 square feet of conditioned floor area served by the duct system, or 3)the ceiling insulation R-value installed against and above the insulated duct>= to the proposed ceiling insulation R-value, less the R- value of the insulation on the 403.4 HVAC piping conveying fluids R- R Complies Requirement will be met. [FR17]2 above 105 9F or chilled fluids ❑Does Not below 55 9F are insulated to zR- 3. ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies 'Requirement will be meta [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 4 ��.......3 03.5. >_ot water pipes are insulated to R R Cl❑Does Notem lien Requirement will be met. [FR18] °pP []Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3j Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 6 of10 section plans Verified Field Verified # Insulation Inspection Value Value Complies Comments/Assumptions & Red ID .�.. 303.1 All installed insulation is labeled ❑Complies Requirement will be met. [IN13]2 or the installed R-values ❑Does Not t,p provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value„ R- R- ❑Complies see the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 Steel Steel �n, ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies Requirement will be met. 402.2.8 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the 1Y underside of the subfloor, or floor ❑Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- ....wwa.. . -R- ._..,... ....,._.mm ❑Compiles See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [IN3]1 exterior,the exterior insulation ❑Not Observable requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable _... .. ... ..n .- ,. N..., .�.._W_.w e.. 303.2 Wall insulation is installed per p ❑Complies Requirement will be met. [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable ......_.......-w Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 7 of10 Section # Final Inspection Provision�ffPla:ns Verified Field VerifiedCom Iles? Comments/Assum tions & Re .ID lue Value P P 402.1.1, Ceiling � ❑ Wood ❑ Woad ❑Doe Not see the Envelope.._..... .�..... ._�..� insulation tion R-value. R- R wn �...�. . ❑'Coms ii assemblies 402.2.1, of table for values. 402.2.2, 402.2.E ❑ Steel Steel ❑Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies `Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable [F .2 3 Vented attics and e with air permeable ❑Complies Exception: Requirement is ave 2]2 insulation include baffle adjacent ❑goes Not not applicable. to that extends over insulation. ❑Not Observable ❑Not Applicable 2 4 Attic access hatch and door R- R ❑Complies Requirement will be met. #1311 insulation >—R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 1 = � ❑Complies Requirement will be met. [FI1 ]1 2 ach i Climate in Climate Zones 3 g5 ACH 50 — ACH 50 —, ❑Does Not []Not Observable ❑Not Applicable 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception:All ducts and air [FI27]1 determine air leakage with ft2 ft2 ❑Does Not handlers are located within either: Rough-in test:Total conditioned space. leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including 'the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4 'Duct tightness test result of<=4 . cfm/100 cfm/100 ❑Complies Exception:All ducts and air [FI4]1 cfm/100 ft2 across the system or ft2 ft2 '❑Does Not handlers are located within <=3 cfm/100 ft2 without air conditioned space. handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection, 403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met. [FI24]1 by manufacturer at <=2/o of Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [FI9]2 installed for control of primary []Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies Requirement will be met. 012 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies Requirement will be met. [FI11]2 systems have automatic or []Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 8 of10 .. .,,m.Section Plans V .�. _.._ ITinspection _ � ovisions feed & R# Final Ins ectlon Pr Complies? Comments/Assumptions e ID P Value U,.....u..,, a Id Value. ..._...... w ..._.m.m...�..._ . _..... .. 403.6.1 All mechanical ventilation system ❑Complies Requirement will be met. [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits per Table ❑Not Observable R403.6.1. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies Requirement will be met. [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature.. 403.5.1.1 Heated water circulation systems ❑Complies Requirement will be met. [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 03.5.1.2 Electric heat trace systems ❑Complies Requirement will be met. j[F129]2 comply with IEEE 515.1 or UL rlDoes Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5 ., ....n...................�......w...e..eeee..,..m . ..�w._e.....�..M. _., 2 Demand recirculation water ❑Complies Requirement will be met. [F130]2 systems have controls that ❑Does Not manage operation of the pump and limit the temperature of the ❑Not Observable water entering the cold water ❑Not Applicable piping to <= 1042F. 5.4 Drain water heat recovery units ❑complies Requirement will be met. [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 90% or more of permanent ❑Complies Requirement will be met. [F16]1 fixtures have high efficacy lamps. ❑Does Not ❑Not Observable ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met. [F123]3 no continuous pilot light. ❑Does Not 1 ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies Requirement will be met. [F17]2 ❑Does Not ❑Not Observable ❑Not Applicable 1 I-I'ilgh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 9 of10 # Final inspection Provisions plans VerifiedFFIeldVerified PComplies? Comments/Assumptions & Re�D alue_.._M a ue � .�.. �. lies -,Requirement 303.3 Manufacturer manuals for ❑Com p q nt will be met. [FI18]3 'mechanical and water heating ❑Does Not systems have been provided. []Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 595 N Parish Drive Report date: 02/15/24 Data filename: Page 10 of10 W i fl' CIp;IWgry,W %Yk. 81WIN18RW m nergy Efficienc Certifica te k W Above-Grade WMalIMMM=21.00 Below-Grade Wall 14.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): M qnindowEMEEMMO.30 0.30 Door 0.30 0.30 Heating System: Cooling System: Water Heater: MOSEEMEMEMEMEMESIMEMEEMEM Name: Date Comments Architect s Letter Subject Property.: 595 N Parish Drive, Southold, NY 11971 ARCHITECTURAL 2/6/2024 Town of Southold DESIGN, P.C. Building Department 54375 NY-25 Southold, NY 11971 To whom it may concern, I, Daniel Kissinger R.A., confirm that there are currently no active gas service lines that exist at the residence of 595 N Parish Drive, Southold, NY 11971 according to the current property owner and National Grid. There will not be any proposed gas lines during the process of the demolition of the existing dwelling and construction of the new dwelling on this lot to the best of my knowledge. The following is the property's Suffolk County tax map number. District: 1000 Section: 71 Block: 1 Lot: 6 If you have any questions, please contact me at your earliest convenience. Sincerely, Daniel Kissinger R.A. DK Architectural Design, P.C. Email: dan.kissinger@dkarchdesign.com @DKarchdesign on Instagram Cell: 631-793-4608 1 of if 595 N Parish Drive, Southold, NY 11971 S.C.T.M.# D18TRICT 1000 SECTION 71 BIOCK I LOT 6 i:Y#9C+' rsoilyT n FxdL[ DECK ID30 5/ a 5I. 9 wP ,ro"wiuccc / (J� tl A+ M1 L r n r ,' c D _ J.S 5, I I.. Y r 11C:PANE WI, f9• �""`•� !� rf ^ ,.�, �\ r.,,1 � ���, w ?A— ANEW W— m 1W iaq F '" + ,„✓'"" omrwasrrrcm OLy'+' o.)" HfiwYwD HNFA 1 qt e N ae "Y G' o'er a r Id B ,I''-` tl•,Iw»w»mu°�,n�FN { r� S wrF:%r N"r ! 4'l ai ,ew. �..dAn• y � 1, ,� 9 I VrJ w " '"�, v• r - !. N./i tlt ;m w rT OL urd as' ^1 nx++wndpwc^AwY d'it r ��ai 2A •IFA6�F 'd#'�Po4"E � y rraAx�rmDr �i �� �.9t �' ��nn.. A'4�feat4l.�Pk.�P.W�A, � muwd•. .P1.0 C47NF „PAdYEL. e. <� °' WIIH kpvl2(NE'SSL1R �w"ulv a °N f ffiDE k.p 'I:Xkd"Xi M ANDAIR aere�E�uA� suPPLYLRE TOAN4W w A`bu«i N 'l/ W^r Add/� �rNO14A3V sv •"^'+ ,,,,� I J'"M'w fa " ry,.,n,? ? "^IEAdDIAtl4'DI67POOLW3.8W Xd'DEEP LEACHING POOLS W2'"DIA %/'DEEP E%PANMON POOLS TAP0Lrr r.sWMWREr WALL Dw ur�.w0i w/wa.w nu. . r�x! r,N'M1'dN"NbM1�'w{Nk.. A„w+m-.Y.S.Wx MutlAx nnnnuxmn m,nnw .aalwtl Dim �armmc'awn�w,m. IUD �" xwwi,.n rA7xw mu r wr+x a< a b�a _ "�r)w=atl .r,��IF u+awtl r „.,.-. ygycn swwr� � "n �W 6111�6'01G�FOOI tI"-ja­ MAN �' ...... .„ w ,. „lLL..W_,_�N.,, ,,, r�aar'w�wtlrrny rlMatlaaamw'wA eiwarirl°osA ¢awcrLYsa ' sw ,,. 9ANRARY INVETfI9 .... , REVISED 10-20-22 p-n Nr W4A PCYb y„mr,Yrlxa OAYHRLS ANO�C,f;'9Y,IL'¢ LMAYI5N'S yl•e0-A1W PMPd',. GH.45;RVAV1&4 AM@ 41w'AA1A OtkNAnWW JA'IMNYA tl'N,M" 31 or 0,55/,cRES t5'(vut r wo MAVDe M d Ile, Sp'a tl Y a 1—MAY NN A& S .,nu F'A` tlMry.. W..k s tx r,Di SCRIFI D x H"1"{d�`"'1 CErt MED O N F GS THE C•LC 6 y ID.rED AT SOUTIiVI❑ rGxN r rl1,T{OlC L JAy A, KENNETH M 1EOYCHUK r.AN VFY D SURINf PII,C c d"" SUrF Y COUH Y.II W lOR, 'tlA'� 11,oresnlonnl Lnwd Sur•cyi.g wnd DL iD ANw P.0•.Rn IM Aqu baCue New YD,L 11113I ':'k 1-/eB r 1 -.C'` cAPk L 0 _r7. "p Yxane laal lLvo Ives YnY lesLl eve lenn CdF€ww FILTER S�ezi rc`�^zt 19 lffLri.RK T@V + 'i Li Sd%$T AF CikP;VARIES £ ;22+"C`4 - ➢IA llig eY- SA i PI�CH DI/13%Pi gC. 6'DIA 3 9' _ -4 < - i71 OISTRIBDiIRI LEACHING -- ® ® ® In g #� gp V4s AV 6OD P00L FOULS8 ® ® ® Q. EL42 #'Im35 ® ® E3 P3 I/D'/fT 09CN k 35 CROSSOVER PIE *xd,Z F r �T:g:OF POOL Is � a SET gc 2•PRDN®TTOM OP PDDLw BIB As SANRARY INVERTS - _m � HYDp➢A TION OVIT-PANELVAND ACR—PUlmT .6 C?"TRQL PANEL COMPRESSOR T e Yr WOIENWATFA EIEV 2 A 4ASKt: '•'<. ' - s. ll __ -_ ?Z h=� TEN INPAE ;.$ SANE s' ` - RA-R.-� - F • C `- PRECAST LEACHING POOL -21 21 i 4 s AMPTEAT YOIVKLs �- •Yp i Rypv. , t ARSE _- r � ' a,`Y � TOD`IOiC� pE a € A sw o.. e- �'-, . . ..:rya �s IilS�'Mf � [:W$71]#-- } IMF - 1 IS'rTSkE. TA; O�TIySL .O RE WRS Om DI TIE WRETPIP[ LL - 23 wATEN EI£v D ' a, - _ •� S [ It IT SYSTY NUXUIn' CLEANOUT DETAIL .N H�aEsr Elm LT2v2 �� LIIu :$ tsFa1`47t�`14'. /wD r 1: I.Ml 0 C.0 m BEIf RAII SW'MIT IIIN00s MO s'FIB MM NO P SAN WATER WE[LM PROP - ( I�€7 ACTION AN bop AtiX iMr �"� '*•FT € ; \ tL M{.MCA O'ddT�l AIEbSL�OSNAI'E?wKRTLs Dwauxcs dO �1sA D$T"WETLANDS SETBACK MM ffi1' € FA BOAAI'HPIWOLim w/Pueuc wATw b =.-a�.a'3<' ` N "B �.-_..$.. ' cxarc srr 6 A r' h INF1 81•�1'Il'.YlOL I105 `.a;' EI r. D ` - a€ AK-080917-1 < NOTE: ENCLOSURE ' {+ _ '"� HINGE TO THE RIGHT - - -. A �._.S aL E?A M SEPTIC TNRCO - • - g 9 BARgtEA O le %i �F r � � - RE�DDNEE NDD�.AY C V�u T I Ate• ,�: ,�� �-�,� ��-� ;*ZE � � - -- EX OjN�s TA9� z. /, i �`� 32 `•-�. TO AN 6001 PLC PANEL � � -_ - _ �n`� S 1SE_ 5 r f GCONTROL PANEL ` WITH HP120 COMPRESSOR r s CT AND AIR } r r SUPPLY LINE TO AN600 = ; AN-600 O - :T- .t DES -- a - EA B'DIGNAN-6TPOOLWB-B'DIA � - X4 DEEP LEACHING POOLS 2-6'DIA QNNL3 1 t RETAINING WALL A Te H? AS7 TBR SDmOA LY C##Lt �Aa4 SCDH APPROVAL M600 NYQ VIIH&W OVI$ m BtYO p 9RH1 II91 W9IDIlI LL MO!IL/Al1P[ - pjl �g ' sa TO 2G #;r .axx ---I➢ISIIIG CINTU - -. ------^ -- .._ IN Aeer�n-'P.E. l S R�D[D 991 EIfVAil01 - a R[Y I .a R€vgp: Y 91 DOI INRR ��� F ALLSORMIN SCALEI"-20' —VM—VA1�IR WEE -F. :SAW-11REVATER �,€ I 585 NORTH PARISH DRIVE E Wf EILLTRIt 502V[� LWE €€LIr at a S.C.T.M.# DISTRICT 1000 SECTION 71 BLOCK 1 LOT 6 s s �7OA NYSDEC 4 IXISIING LOT COVERAGE (UPLAND AREA:23,450 F. DWELLING W/SCREENED PORCH:2156 S.F. € J REAR DECK. 1090 S.F. DRIVEWAY,WALKWAY&STOOP: 855 S.F. SHOD: 80 S.F. a GAZEBO: 73 S.F TOTAL:5109 S.F or 21.85 1� NYSOEC PROPOSED LOT COVERAGE (UPLAND AREA:23,450 S.F.) #N - ` i' DWELLING W/COVERED PORCH: 19 S.F. ' UPPER DECK,REAR DECK,STEPS&POOL1946 46 S.F. _ ( __ TYPICAL CLEAN OUT SHED: 96 S.F. - _ = t� L _ SLATE OR•�� �-END GAZEBO: 73 S.F. _ `^a URAOR PuIG TOTAL•4110 S.F.or 17.55 rX. \ DWELLINGS 7 I W/PUBLIC WATER 37 ELBOW TOWN OF SOUHOLD 150' ._ � - f- - EXISTINGLOT COVERAGE i t y (UPLAND AREA 23,450 S.F.)_ 7 Vii�'d "'+„ €- =`.3� FLOY--g- E1.a2O DWELLING W/SCREENED PORCH:2156 S.F. EXISTING 1 STORY o y `+.- r . DWELLING 8 DECK .,, j"�� ',+ �•gg. REAR DECK: 1080 S.F. TORE s�-,� x( ' ---"- x€ e _° OLAND °.3' SHED: 80 S.F. irs€..T: GAZEBO: 73 S.F. H0UP47565 EXISTING SEPTIC TO Of:AAR ?€0 AW 1�s BACKFILLED WITH CLEAN SW' COARSE 6.8` TOTAL-3398 S.F or 14.5% COARSE SAND SAD ' { WELLINGS TOWN OF SOUHOLD O PROPOSED UjG W/PD ueuc waTEx PROPOSED LOT COVERAGE '.: e ' $� 1? 150' (U ELECTRIC SER PLAND AREA 23,450 S.F.) 1t`s0E -. rr�z ELEV DWELLING W/COVERED PORCH: 1995 S.F 4, 6Y ' L$ HIGHEST EXP ELEV zo- —7_1' UPPER DECK,REAR DECK W/POOL: 1894 S.F. - - b £ Y � � 06-21-21 SHOD: 96 S.F. _ # - ,.,�� � �.'` KWOYCHUK LS GAZEBO: 73 TOTAL 4058 S.F.or 17.37G T.H.01 r �` _ e01/NaVlY EL 125 VIXTDSW ASPHALT HF€VA E RTC SERVICE °L AND LOAM 2.5' p TO HE 4dH IEO TO AN 6001 PLC PANEL sP 8.5' d LC CONTROL PANEL HIORM t _ P WITH HP120 COMPRESSOR WATER ELEV 1.0 RR OPWAT S€AVI E 1' IN EGTRIC AND AIR �- SU _ a / . PPLY LINE TO AN-600 WATER IN ROAOT[ AN-600 SW SAND 6,0' T #1` ` 1 EA 8'DIA x 4'DIST POOL IN3 8'DIA X 4'DEEP LEACHING POOLS W 2-8'CIA X 4'DEEP EXPANSION POOLS OR eq, I f` B ( y` � � # DE—AMNONSNASTARYRETAININGWALL - c17' � "-- - KWOYCHUK ILS v DWELUNGS r W/PUBLIC 4YA`OTi. _ 150' LEGEIID LP-PRECAST LEACHING POOL EP-SMISI I LEANIru POOL LOCKING COVERS EFFLUENT FILTER AI=OUTLET PIPES TO LEACHING r0vt.t0 hx DO.O.E off DWELLING VARIES FF 125 -TO GRADE POOLS TO BE SET AT SAME INVERT MOVES o tt.O GRADE 115 �11 Ors rA `-E' g PN�V7_HYORORCTIONNIEASMIG E�SNIIGCOiITOUR -- - _. --. ----- - TMIN - x(XX.X') PREMSPOTEIEVATION --- PROPOSEDCOIROUR tom'DIA afi•DEEOIAp'a =uaa 4'SD 35 PITCH7l4"IFT _ - 4'DEEP R LI"-O 4' P L _'' LVATER'�CR�'('E .. - DISTRIBUTION LEACHING DICE VRICSEWCE POOL POOLS —�. AS 1C WALL - g1O IL 4"SDR 35 CROSSOVER PIPE EL4.2 4'SDR 35 BETWEEN LEACHING POOLS --—--- PITCH 7I6"/FT3'MIN S§�A.RI3SmbYcRTFf a LEVEL 2 FROM BOTTOM OF POOL iv.:3O SET LEVEL 2 FROM BOTTOM OF POOL SANITARY INVERTS REVISED 01-19-24 REVISED 08-01-23 REVISED 10-20-22 ZONED R-40 THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL NON-CONFORMING LOT LOCA17ONS SHOWN ARE FROM FIELD OBSERVA77ONS FRONT YARD:40'MIN AND OR DATA OBTAINED FROM OTHERS. SIDE YARD: 15' MIN(TOTAL 35') AREA:25,426 S.F. or 0.58 ACRES ELEVATION DATUM: NAVD88 UNAUTHOR12ED ALIERA77ON OR ADDI770N TO THIS SURVEY IS A VIOLATION OF SECRON 7209 OF THE NEW YORK ST47E EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY,GOVERNMENTAL AGENCY AND LENDING INS77TU7701V LIS7ED HEREON,AND TO 7HE ASSIGNEES OF 7HE LENDING INSRTUDON;GUARANTEES ARE NOT 7RANSFERA 7HE OFFSETS OR DIMENS/ON5 SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR 70 GUIDE THE ERECDON OF FENCES ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS EASEMENTS AND/OR SUBSURFACE STRUC7URES RECORDED OR UNRECORDED ARE NOT GUAWJTWF.UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE 77ME OF SURVEY SURVEY OF:DESCRIBED N CERTIFIED T0: NIKOS THEODOSOPOULOS; Al MAP OR - =o- J� FILED: S,am ,7 SITUATED AT..SOUTHOLD 1 TOWN OF:SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK b =- �� Professional Land Surveying and Design P.O. Box 153 Aquebogue, New York 11931 PHONE(e31)290-1688 FAX(631)298-1588 FILE N 221-48 SCALE:1°=30' DATEAPRIL 30, 2021 N.1�S LISC.No..