Loading...
HomeMy WebLinkAbout50479-Z DRAWING LIST KEY MAP ABBREVIATIONS DRAWING SYMBOLS C� �— , v SS� i'S o # DRAWING LIST NOTE S,C,T,M, # DISTRICT;1000 SECTION;97 BLOCK;6 LOT;10 R-80 DWELLING ABV Above AN Finish PVC Polyvinyl Chloride AC Air Conditioner FLR/FLR'G Floor/Flooring _ R&S Rod&Shelf � BUILDING ----------------- SETBACK LINE ACT Active F.0 Face Of R/RAID Radiator SECTION L_ C T-100 TITLE SHEET,DRAWING LIST+SITE PLAN ISSUED-DOB o AD Access Door FPSC Fire Proof Self Closing RD Roof Drain w } CL ADJ Adjustable FTG Footing 0 W WASTE STACK �- � o y REF Refrigerator WALL = a w AFF Above Finished Floor FT Fin Tube REINF Reinforced AP Access Panel G Gas SECTION D-100 DEMOLITION PLAN ISSUED-DOB BD Board Galv Galvanized REQ'D Required --� OLD LEADER DRAIN L" N RM Room �� ENLARGED "_ w BEX Bath Exhaust GC General Contractor Q w �O��E25 BO Bottom Of GYP BD/GWB Gypsum Wall Board RV Roof Vent DETAIL/PLAN Q Q A-100 BASEMENT CONSTRUCTION PLAN+CONSTRUCTION DETAILS ISSUED-DOB BRG Bearing H2O Water S Sink 0 FD FLOOR DRAIN Uj w BT Bidet HD Head SC/SL Self-closing/ XX X EXTERIOR 0 N A-101 FIRST FLOOR FRAMING AND MECHANICAL PLAN ISSUED-DOB pelf-latchhin ELEVATION --� zCO BTM Bottom HIM Hollow Metal SD Shower Drd�n 0 V VENT STACK W A-102 FIRST FLOOR CONSTRUCTION PLAN+CONSTRUCTION DETAILS ISSUED-DOB CAB Cabinet HP High Point X w o HWH Hot Water Heater SD/CM Smoke&Carbon21 CBU Cement Backer Unit ROOM NAME A-103 SECOND FLOOR CONSTRUCTION+ROOF PLANS ISSUED-DOB Monoxide Detector x xx X INTERIOR CONSTRUCTION PLAN C CL/CLOS Closet IM Ice Maker SE Security ELEVATION FLOOR FINISH CLG Ceiling INSUL Insulation �� Shower X ¢ «� CMU Conc,mas,unit TNT Interior SIM Similar ROOM NAME A-200 BASEMENT REFLECTED CEILING+ELECTRICAL PLANS ISSUED-DOB F� CNTR Center JMB Jamb ELEVATION REFLECTED CEILING PLAN �F CONC Concrete LAV/L Lavatory ST/STL Steel CEILING FINISH A-201 FIRST FLOOR REFLECTED C-EILING+ELECTRICAL PLANS ISSUED-DOB �F JS Jamb Switch STV Satelite INDICATOR o s CS Clinical Sink SEX Stove Exhaust o CONi Continuous MAH Mahogany A-202 SECOND FLOOR REFLECTED CEILING+ELECTRICAL PLANS ISSUED-DOB 90 MC Medicine Cabinet T Toilet p)O( DOOR AND FRAMED ----------H20---------WATER LINE J z CT Ceramic Tile CREST Crestron MECH Mechanical TB Towel Bar OP'G N0. TE Telephone 0 CTV Cable MIN Minimum TO Top Of LP---------- LIQUID PROPANE GAS LINE p D Dryer Mnfld Manifold TP Toilet Paper Holder XX WINDOW NO. DH Double Hung E— o DIM Dimension M.O. Masonry Opening TR Towel Ring cn o MTD CONSULTANTS DR H Door Head Mounted TRANS Transparent W WASTE LINE DTL Detail MT- Metal TYP Typical CABINET ITEM W DW Dishwasher NAT Natural UON Unless Otherwise Noted r NIC Not In Contract VCT Vinyl Composition Tile -----------PP----------- PERFORATED DRAIN PIPE «7 DWG Drawing —,—,—._, w SURVEYOR �, DWR Drawer OC On Center W Washer Verify In Field CENTERLINE w b Q ORE Owner Furnished p "0 CLIJ , E Electric Equipment <�l KENNETH WOTCHUCK EA Each WA Waste ----- S ---------- STORM DRAIN " o PROPERTY OF; n OFCI Owner Furnished WC Water Closet ALIGNMENT F z PO BOX 153 EL/ELEV Elevation NEAL BAUMANN+KELLI FERGUS &Contractor Installed WD Wood A6�UEBOGUE NY 11931 1415 HARBOR LANE EP Electrical Panel � � HOSE BIB EQ Equal OPP H Opposite Hand WDWK Woodwork DIRECTION OF MATERIAL HB OFFICE; 631.298.1588 CUTCHOUGE NY 11935 EQUIP Equipment PL LAM Plastic Laminate WH Window Head W.O. Wall Oven --+a HOSE BIB W/HAND HELD IXSTG/IX Existing PLYWD Plywood HHS REVIEWING STRUCTURAL ENGINEER EXP Exposed POP Poplar VS Vent Stack -________- CONSTRUCTION SPRAY JOSEPH FISCHETTI,PE EXT Exterior PT Pressure Treated BELOW __0 GAS AD Floor Drain PTD Painted 1725 HOBART ROAD FAI Fresh Air Intake _—_—— CONSTRUCTION — SOUTHOLD,NY 11971 FF Finish Floor — EXISTING ABOVE CONTOUR OFFICE;b 1-765-2 54 PROPERTY LINE ——'——' NEW CONTOUR U,O.N, I SITE PLAN- 1 :20 I z I I 0 I U I I I I I I I I I I I I I I I I I LAND OF WILLIAM & ELEANOR FORTE _ N I LAND OF PETER C. STERLING o I TIDAL WETLAND BOUNDARY AS I N 67046'00II E DELINEATED BY EN-CONSULTANTS 1.2'N 4'WIRE FENCE ALONG LINE 542,00 DEC, 22,2016 — X X X X I X X X X X X X X X 1,2 N \ TIMBER WALL O/L ` �r \ `0 w c-> WELL y - � O Q � \ 6 FRM,GARAGE � Q � o w/LOFT t ' o o O FRM 8 � CONC.RE[. p DRAIN 28,3' SHED 1 0 1 I FF19 A ^ o � � ' o STONE DRIVEWAY WALL 10 212 / 14 z TIMBER CURB I w PLAN STONE DRIVEWAY TIMBER CURB I z i � I NORT STONE DRIVEWAY GATE pOR \1 t 0 DIBM k I J GATE o�10 f- m SHOWER 132' � OOD R WOOD FLOATING r t W A 4,W AIL FENCE o 13�' \ t STEPS d5 RAMP = STK. L,P,GAS 13.1 \ \ t W OD ALK 6'x20' CD O � \ FLOATING G POOL 000a� GATE 9� DWOOD 5, DOCK W C) 9TF EQUIPMENT p 1 STY FRAME ECK 5 ` ; 7 w 4 cn � GA a � � �, � \ z w DWELLING z FFL 20.1 C.P. z J 9'b ' Q 10 Cn _ Lo � >— O WOOD Lv w c� � CV CESSPOOL&WELL \ DECK z 0- Z CD z LOCATIONS PROVIDED O } J Q 0 BY PRECISION MARK-OUTS INC, l O o 0 12/30/16 191' 'f� = 0 LU cn CN o SPA m o z z _ N , ' 3 i ` \ ti � a' �w I 14 12 10 I '� z �- Q 16 U o Q L,P,GAS 0 18 ' �y Z w � \ = w N b 46'00" E 5.3'N 4'WOOD RAIL FENCE � \� ��-� `oe �`, Q O STK. 77,72' STK, 32,51' STK. STK, 4,8'N STK. 1,3'N �� m � STK. STK. STK. ' STK, N S 67"46'0011 W MAP OF EAST CREEK ESTATES #12120 590,00 I \ -� c &o EE LOpF� X L EXISTING HOUSE TO BE RENOVATED/MODIFIED IN EXISTING FOOT PRINT+SHELL - -NO MAJOR CHANGE TO EXTERIOR-REPLACEMENT OF EXISTING SLIDING LAND OF DAVIDRURBARA HAZARD * GLASS BASEMENT DOOR-SOME REPAIR TO EXISTING EXTERIOR STAIR+WALKWAYS- .a=,,,,. �k INSTALLATION OF EXHAUST FANS ON ROOF, -DEMOLITION OF EXISTING BUILT OUT BASEMENT N -CONSTRUCTION OF NEW BUILT OUT BASEMENT CONFIGURATION Og3290 O� �4" WITH NEW CODE COMPLIANT STAIRCASE TO FIRST FLOOR OF N y -RECONFIGURASTION OF EXISTING MECHANICAL SYSTEMS Seal -MINOR EXISTING KITCHEN RECONFIGURATION -DEMOLITION OF SECOND FLOOR/MEZZANINE/ATTIC SPACE TO BECOME LEGAL STORAGE T- 100 �o O U � U U zQ Z ry JW d. p = O LU W Q � W w Q C) w _ _ N .. .. - N N CRAWL SPACE � REMOVE EXISTING TREE STUMP J BEDROOM 3 ` EXISTING WOOD 1 1 REMOVE EXISTING 12"H RAILROAD -- - o C) cn o TIE STEP Lij REMOVE EXISTING FAILING CONC SLAB+ DRAIN GRATE W o c+7 w � r - � CO REMOVE EXISTING FRAMING =_ +EXISTING ELECTRICAL SUB PANEL n I REMOVE SLIDING DOOR+ CLST 'a 1 PORTION OF FRAMED WALLS LJ _ CLST HALL 2 EXISTING WOOD REMOVE EXISTING AREA OF FLOOR+ROOF EXISTING OPEN REC ROOM BATH 2 TO INSTALL NEW BATH EXHAUST 11 EXISTING TILE BEDROOM 2 1 EXISTING WOOD REMOVE ALL EXISTING UNUSED MECHANICAL EQUIP TYP, BEDROOM 1 CRAWL SPACE EXISTING WOOD REMOVE EISTING �) SINK,CAB,X MIRROR+TILE FLOOR N w 0 AREA OF SLAB - - r- TO BE REMOVED HALL 1 r rl-I r r r L JI11 LLIJl ILL EXISTING MECHANICAL EQUIP �, II EXISTING WOOD 1- H1� H1- +1- 4 �1-1+ 1-1-I+ TO REMAIN l u T r1-1 r - 7 r1_17 T-1-1T ` I I REMOVE LIJ 1 LIJ I_I1 LI_I1 LIJ 1 ------------------- ---------- EXISTING - a CLST CABINET rrl F17T i HARDWARE--- � _ �� t REMOVE EXISTING BATH - - WALLS,SHOWER, - - r '- - � REMC� E PORTION)OF SLAB ENCLQSURffiMfSHES 4---- ------i---_- Lu FIXTURESFORNEWSUMPiPUMP -- II II f . , , r--------------- I L- ------------ - o 1 _ `-i--- ❑ - - II ( ----- rIIIF1IIIIII -------------------- REMOVE EXISTING APPLIANCESREMOVE PORTION OF R Ic__-__ EMOVE EXISTINGUPPER+BASE CABINETS AS REQUIRED FOR KITCHEN DINING RM. REA OF FLOOR+ROOF REMOVE ALL FLOOR FINISH T��LABTYP' UPDATES SEE SHT A600 0 INSTALL NEW KITCHEN EXHAEXISTING WOOD ONG BATH I REMOVE EXISTING KITCHEN REMOVE EXISTING SINK+FAUCET EXISTING WOOD HVAC DUCT WORK EXISTING DECK ------ ------ : REMOVE EXISTING EXISTING WOOD ----------- �,r---- ROLLER SHADE Lu Lu OUNTER TOP REMOVE EXISTING L IC -3 REMOVE — H---- ❑-- ---------- ; 0o EXISTING LL BUILT IN BEDS+CLOSETSIXISTI G LAUND - i� REMOVE A RAD L----- AS REQUIRED TO LREMOVE EXISTING EG4TORAGEREMOVE EXISTING L UNDEY ----__ h------ri STAIR WALLS+CABINEISWALLS FINISHES,FI URES+ REMOVE EXISTINGAPPLIANCES Lu --- ------ - ' i BASE AS REQUIRE o --- ------ FOR NEW CLOSET P P4 ,L AU=F>z N- E- �— ,T ORUoJ1�zzJjo��ENORT NORTH Tnr �H REMOVE EXISTING STAIR+STRUCTUf REMOVE PORTION OF FLOOR+STRUCTURE AS REQUIRED- FOR NEW CODE COMPLIANT STAIRCASE___ ___________ _ LIVING RM.REMOVE EXISTING RAISED CONC. -----J EXISTING WOOD -- - ---- ' FLOORUNDER LAUNDRY+BATH ENTRY/SITTING RM. r EXISTING WOOD ISTING CRAWL SPACE - - - ---REMOVE ALL FLOOR FINISH IXR � ---- ----TO SLAB TYP, EXISTING MECH/STORAGELu -------------------J------- REMOVE ALL EXISTING UNUSEDEXIST NG MECH AL EQUIP MECHANICAL EQUIP TYP, WTOR MAIN Ln zEXISTING EP TO REMAIN QO 0 Lu lip IL F7co Lj- Lu uj EXT'G HVAC EXISTING H EQUIP, T TUB EXT'G HVAC EXT'G HVAC EQUP, EQUIP, SLAB ON GRADE SUN RM. EXISTING WOOD a) EE L((o) N3290 OF S- e al BASEMENT DEMOLITION PLAN 2 FIRST FLOOR DEMOLITION PLAN 2 SECOND FLOOR DEMOLITION PLAN D-100 SCALE. 1/4 - 1 0 - SCALE: 1/4 - 1 0 EXISTING EXTERIOR WALLS THE CONTRACTOR IS TO VERIFY ALL MEASUREMENTS IN FIELD+ANY - --' --" O EXISTING SUB FLOOR+FINISH FLOOR DISCREPANCIES ARE TO BE BROUGHT TO THE ARCHITECT/TEAM PRIOR TO CONSTRUCTIONS, LO 10,ALL CONCRETE 3,500 PSI AFTER 28 DAYS MIN. 27 NEW PTD WOOD STAIR )I �� EXISTING 2X8 FLOOR JOISTS 13 RISERS @ 7,375"±-12 TREADS @ 10" ;�, _ Y i l ALL REBAR ASTM A 615 GRADE 60 (COMPLIES W/2015 IRC R311,75) G� I = 0 w 1 == FOOTINGS ARE TO BE ON UNDISTURBED VIRGIN SOIL. I Q N Lu EXIST - REFLACE ALL EXISTING BATT INSULATION \ J Q w - 6 STEP (R-SO) ALL SNAP OFF FORM TIES ARE TO BE REMOVED AND REMAINING OPENINGS ARE TO BE --.. Q = SEALED/GROUTED w_ 1 1 I V 1/2"MOISTURE RESISTANT GYP BOARD I I I O Z -0NEIV 31/2'BATT INSULATION(R13) BACK FILL ALONG FOUNDATION WALLS IS TO BE CLEAN MATERIAL+IS TO MECHANICALLY COMPACTED W o I 1 1 IN 6"LIFTS TO 95%OF MAX DRY DENSITY - w C> Q REPAIR/REPLACE EXISTING BRICK 6" _-� ; NEW 2"BOARD INSULATION(R12,4) 'll 2 H _ I I CRAWL SPACE ' LANDINGS AND 6X6 -__ = N ( ' A R ' I TIMBER STEPS+WALLS FOLLOW COLD WEATHER CONCRETE TREATMENT RELATIVE TO ADD MIXTURES N ACCORDANCE WITH ° 1 < - EXISTING 8"SOLID FILLED BLOCK WALL ACI 212,3R USE AIR-ENTRAINING AD MIXTURES PER ASTM 0260,AASHTO M154 OR WATER REDUCING+ NEW �11L TOM WObDAS REQUIRED SET-CONTROLLING ADMIXTURES PER ASTM C494 AA HT HAND PTD WOOD _ S 0 M 194 ONLY,DO NOT USE CALCIUM ST, (EK BALUSTERS 1 I i I EXIST - CHLORIDE OR OTHER CORROSIVE TYPE ADMIXTURES I I I 6"STEP = ( O LIES W/2015 Lu A RC R311 J,8) o U I I I _ C7 1 OVER EXISTING DSRTB I 1 bXSTEP ,� w �X x_ I IIST I I U CRAWL SPACE REPAIR EXISTING 12"STEP r- U _ - q 1 1 o STRUCTURAL DETAILS PROVIDED BY; 2 NEW 6"H STEPS CD W/ z +I z JOSEPH FISCHETTI,PE TQQ MATCH EXISTING TIMBER NEW (2)7LIJ ,25 LVL(FLIP H}' 1 1 1 I 1 STEPS X I 1725 HOBART ROAD I 1 I 1 o SOUTHOL Y 11971 t� o w NEW CONIC,SLAB Lu D,N - _ __ - _ - - _ =- 6"STEP I EXISTING LOCATION o NEW 7,25 LVL(FLUSH) SITERED _ - I 1 I o - FOR EXISTING DEFLEC I N W r 2 SIM , 1 6 - - NEW DRAIN CONNECTED _ TYPICAL FOUNDATION NOTES r A1oo � w i A100 I I TO EXISTING DRYWELL 4 �II - - — — — Lu - ------------------ --------------- -------- II -- - ------ -- ----------- --�� I ® � c r------------------a - - - - - ----- ----- --+----- --- NEW1/2°MOISTURERESISTANTGYP.BOARD C� — —i— — —co— — — I i _ _ I I I 2STEP - - - - - - 1 INEWANDERSONIMPACT REMOVE PORTION OF i i _ 1 -1 - 2 I I 1 I RATED SLIDING DOOR EXISTING SLAB AS REQUIRED. 11 ' 8'-7" 5'-b" 7'-10' 1'-5" r I I 1 ' 1IN EXISTING MASONRY OPENING = OMPACT SOIL+REPLACE SLAB o , I 1 ' AFTER FOOTING+WALL IN INSTALLED O , 1#FWGD70611 - - - 1 I +' w SIMPSON LSCZ I - - - - -- - - -- ' U,- - - - - - - - - - - - TRINGER HANGER _ _ _ _ _ _ NEUJ 4" SLAB ON GR , I NEW 12'H2O NE 12'H2O 1 I ' I INFILL+SEAL UP ALL EXISTING OPENINGS , I BASEBOARD I BAS BOARD '1 I _ _ _ _ _ _ _ _ _ _ _ _ _ 1 +i i i z z 1 TO CRAWL SPACE INSTALL WOOD ACCESS I I REC OM 1 I u 12 + I I - NEW(2)1.25 LVL(FLUSH) w _ - - - - - - - - - - - DOOR IF REQUIRED TYP• 1 I a 1 ' EXI EXISTING SLAB ' Vin I Floor STING 16"X8"FOOTING I i y I 1 1 I NEW PTD WOOD STAIR ,. , 8"POURED CONC,WALL ' NEW 2 G I I 13 RISERS @ 7.375"±-12 TREADS @ 10" - 11'6" b" i A100 TO REMAIN INTACT EW 4" SLAB ON GRADE ' 1 (COMPLIES W/2015 IRC R311.75) DRAIN UNDISTURBED EXISTING SOIL N i i i LI ' - POURED CONC•FOOTING / KEYI I EXISTING SLAB r I I CRAWL SPACE - - - ---- - I - -- - -- - _ I 1" X NEW 4"COLUMN - - -r-OTING -j- - --, ----- _ - - -_- - I :, �,, ,� °° (3)#4 CONTINUOUS i i , I I W/24 REINFORCED W/ +- EXISTING SOIL TO REMAIN U I / 1 (4)#5 EACHWAY 3"FROM "1 -- _ WHERE POSSIBLE UNDISTURBED r - +PACKED SOLID I 1 I BOTTOM OF FOOTING -T-J - I _ Lu z J I AREA OF BASEMENT A100 I Q O BE COWERED 3 " A100 3'-11 5'-3" . ; ; 2 EXTSCALERIOR ,o ALL SECTION @ PROPOSED DROPPED SLAB SECTION DTL @ PROPOSED DROPPED + EXST SLAB 5 SECTION DTL @ PROPOSED DROPPED + EXST SLAB I _---_-- ___-- _ -__--- ---I___-- I % SCALE•3/4 10 SCALE:3/4"= 1'0" I ' NEW(2)7.25 LVL(FLUSH) ___ -__ -__ __--- -- A100 SIM . , I TING 4 COLI�MN EXISTING +FOOTING 4 _- - - - - 1 NEW 2'H2O ' r--- ----------- -- 1 HVAC - - - - - - -"- 1 BASEBOARD ' + EQUIP _ _ ___ r�I�p�__ ` 1 1 - EXISTING FIRST FLOOR TO REMAIN , 6 - - - - Lu , SEWER 1 I ? 1 EJ TOR PUMP ' EXISTING CL$T Vinyl Flo D06 WC i o N '� NEW(2)7.25 LVL BOX BEAM EXISTING 2X8 FLOOR JOISTS c) SEPTIC I 1 5 A602 1 A I EXISTING 2X8 FLOOR JOISTS I r1 - - i '1 � i I •I''' I r ( �,�� ! I �• 1 a '1 , 1 D04 1, � l .I �•:i1 ( � i ............ ' 5,-3" DO1 12'1111�' Vinyl AF oor. l S ER - ' o TIe1- E_X�STIN_G 4"COLUMN `"' ' j i'' 1 ,+FOOTING - NEW PTD WOOD STAIR W/WOOD HANDRAIL+ _ O 03 I z D06 l D04 D03 PTD WOOD STOCK BALUSTERS I I , " c� (D w ' — z (� rz 13 RISERS @ 7 375"±-12 TREADS @ 10" AIR HALL I I �; _ +' _ -7+� w - wLu w c� - z- z _ (COMPLIES W/2015 IRC R311 J5) Vinyl floor i /D Y'ER +� w z o o w cDcof - 1 UP U(�I S i �- PTD GYP CD " € z z ! �� z j M J n O ULu Lu rp m i wfVEW EECTTR U�l- o ---------------------- I 1 '\\6" "i I 'II�� { 9'-4"± i U I' /��`W SHE +,, E :,__=_ J:-- - -- -- -_- o 1 I I - - - \ r . 1 /D YIER ;' (( U ( _____------J, i'I �' it = Ir---- -- - - - - Vinyl „ r,-- - - -- -- ---n �' PANTRY l i l I I I o I I 1 , Floor, � �, w = I 1 NEW 4"COLUMN -r- i- i - - - 1; I NEW +' „ i -11EI�JJILOOD_.SIAII -----� ' `====_--===-J `-_-=--`=-==--=--° S W/24"X24°X12 FOOTING I 1 I l ` i - - o ' I REINFORCED W/ �- - -- DRAIN 1 +� (4)#5 EACHWAY 3"FROM 1 ' FRIG I -- - —= - — LA P N 1 1 � DRY CL N LAUNDRY �--- ' 11-- , BOTTOM OF FOOTING 1 I N CLOSETVinyl1 I —.___.__.— — — '-- — -�- — — — NORT TRUE 1 I 1 I Floor 1 I I I - I I NORTH I CRAWL SPACE , , ; +� I I- V..- I EXISTING SLAB EXISTING FOUNDATION WALL' 1 1 1 3, 3'2' ± 11'-8"± I 1 :.__..-SEE DETAIL 2 NEW LLOWERED SLAB D S -••- +FOOTING : Z SEE DETAIL 3 ' I INFIL +SEAL P AL EXISTING I I I T SIM NEW WOO STAIRS THIS SHEET SIM NBR -f I THIS SHEE � I L S U L S G INTO CRAWL SPACE-INSTALL WOOD ACCESS „II DOOR IF REQUIRED TYP, 1 1 5 - - l / �== 1 A1OO I u n I I I , I--- I I - - BASEMENT SECTION NORTH TH I SOU RECROOM VES TIBULE LE/ U HALL LAUNDRY I I I U DRY STORAGE I b „ „ I I SCALE;3/8 = 1'0 I I MECHANICAL/STORGE , W 1 I 1 PTD,CONIC. p07 I I U EXISTING FIRST FLOOR TO REMAIN Z + EXIS ING BOIL �' I ' W z HO DING T K EXISTING STORAGE I 1 ELECTRICAL PANEL PTD, ONC, i i EXISTING 2X8 FL JOISTS NEW ANDERSON IMPACT (/� z RATED SLIDING DOOR W ,______________ _______-r !___ ____________ _______-__ _-__-__ ____ __! i EXISTING DUCT K IN EXISTING MASONRY OPENING w O J ------ _ -.. EXISTING(3)2X8 E M #FWGD70611 _ < ---______ __-_ I I I IL 1 � r, }' 1� 1 / �' 1 '1� ��, �.; �I,I i'.,�. , r'�r., �„�, �, � /, � + r i� r, i ii ,i v� 6 I I'' 1, l '''' 1 r ', l I ', }l, 1„ ' ';'� 1r , it . / r 1 '1',' "1 11: 1 l ` I ♦�♦^^ O w 00 A 100 � U INFILL+SEAL UP ALL EXISTING OPENINGS ? ! Q 0 z I 1 I I CR 1WL 1 I 0 w I I I I SPACE 11 i I I I LLB c �cn I R d - I = w I I m i — INT RA SPACE- 0 I 0 CRAWL S ACE INSTALL WOOD ACCESS „ , 2_'+I', 1 1 3_ I I 1 NEW S FFIT I � � U REM VABL A 0 E ACCESS (I � O I hl I' F 9 ,DOOR I REQUIRED D TYP. Q I I QU E I I II. d I it I'I I' I. DOOR U I I • I I a II p z I I s I� I I I II I I i 1 I I !Ile II Io, „ P I r U I w II I u ill III I 1 1 II I Z 1 SLAB ON GRADE w S n = 1 E a I I i c� x A — I i • r $ i I; l r *,' w, i ° C I I i +i w w U' I O 0 �9 +' I C9 w I' ' l • , i gpp a0 z , i U •s ! I. ICI II •- Ir i I— ' w UI 6 U E t r I I I I I II yy 6 I i f I I I' J I II III li k I I k , I¢ C I r I 6 V I b I I I I d 1 III 1 t I I c, II , I ti I I e i I r I EL O I I E I \ A s , I F ill I i I f I I I I I I f 6 P I i a 1 i d I i--r— I iA0 II I L-- --------- -------- ---------------- I 0432 N 1 - ---------- -- SEE COLUMN O� 1 IL 2 NEW LOWERED SLAB NEW 4"C /24"X24'X8 FOOTING SEE DETAIL 2 OF �y 0 THIS SHEET-Sim REINFORCED W/(4)#5 EACHWAY 3 1 THIS SHEET-SIM r Seal 1 FROM BOTTOM OF FOOTING BASEMENT CONSTRUCTION PLAN i BASEMENT SECTION NORTH SOUTH - RECROOM A- 100 SCALE: CA E,3 - 1 0 SCALE;3/8 = 1 0 0 0 �y w zw I Jo Y J I = O w V c � m I I Q c ¢ I QQ I •----------------------- I Zcco I I w J E I 1 w oq I I I I `_: EXT'G I / EXI'G 1ST FLOOR) 1ST FLOOR SUPPLY I , SUPPLY I I I I I I I I I I I I 1 1 I I J I I 1 I E I j t 1 I :.................................: MECHANICAL NOTES o 1 i i I ALL EXISTING HEATING AND AIR CONDITIONING SYSTEMS TO STAY IN PLACE+ARE TO BE w MODIFIED OR EXTENDED FOR NEW BASEMENT LAYOUT,IF CHANGES ARE REQUIRED/MADE DURING I I I I I CONSTRUCTION TO ANY EQUIPMENT-ARCHIECT/DESIGNER WILL PROVIDE REQUIRED INFORMATION " w I Q �___________________! _____________________- i_--- __---NEW(2)Z25LVLBQXBEAI\i__-_ AND FILING TO THE BUILDING DEPARTMENT AS PER CODE, w �V ---- 1 r---------- --------a - ------ ---- - -- ,, - --- =------ -- ` -EXT'G I ' 1 ' I - 1ST FLOOR i I 1ST FLOOR I I SUPPLY I I yrr a) I I w, _ 1 Z= I I 1 ' ' CFf TARSI p ! ¢ CELLAR SUPPLY I r-- I ' i I 1 EXIST PLUMBING WASTE LINES TO BE __.l I I EXISTING DECK FRAMING !{ A a GRIT I I TO REMAIN AS IS ®WL �L, NAILING SCHEDULE ' EXISTING 2 x 8 FLOOR JOISTS ►1 ROOF CEILING FRAMING COMMON E 'I I EXT'G JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING 1 1 ST FLOOR I RAFTER TO TOP PLATE(TOE-NAILED) 3-8d PER RAFTER CEILING JOIST TO TOP PLATE(TOE-NAI LED) 3-8d PER JOISTLu z CEILING JOIST TO PARALLEL RAFTER(FACE-NAILED) 4-16d PER LAP j ' I ' cn l , I CEILING JOIST LAPS OVER PARTITIONS(FACE-NAILED) 4-16d PER LAP 0 i I I WL 1 COLLAR TIE TO RAFTER(FACE-NAILED) 3-8d PER TIE 0 r 1 BLOCKING TO RAFTER(TOE-NAILED) 3-8d EACH END EXIST FLUMB'NG WAST LINES TO BE RIM BOARD TO RAFTER(END NAILED) 2 16d EACH END . .................................... ........ ' I ----- REWORKED FOR MAX LNG HEIGHT WALL FRAMING - - - --------------- --- - ---- JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING X 1 - --------------------_-- ' --- 1 1 W 1 1 : TOP PLATE TO TOP PLATE(FACE NAILED) 2-16d(1 PER FOOT TOP PLATES AT INTERSECTION(FACE NAILED) 4 lbd JOISTS EACH SIDE ' 1 1 1 LUU11 I EXISTING 2 x 8 FLOOR JOISTS -- I I - I , STUD TO STUD(FACE NAILED) 2-16d 12"O.C• ' SUP LY HEADER TO HEADER(FACE NAILED) 16d 16"O.C•ALONG EDGES ' ------------- �-- ' EXIST R T i ===_=_ ------------ 'EXT'G TOP OR BOTTOM PLATE TO STUD(END-NAILED) 2-16d 1 PER STUD TO PLATE,10"WALL HEIGHT MAX 1 1 -_ __ .a_____ -- _ I i 1S?FLOOR BOTTOM PLATES TO FLOOR JOISTS,BAN)JOIST 2-16d(1,2) PER FOOT ' I SUPPLY ENDJOIST,OR BLOCKING(FACE NAILED) 3-16d AT BRACED WALL PANEL �,, N ' --------------------1 1 \.r----L-� -J - -- - - ------1a AUST- FAN 1 I FLOOR FRAMING I I JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING JOIST TO SILL,TOP PLATE OR GIRDER(TOE-NAILED) 4-8d PER JOIST EXISTING 2 x 8 FLOOR JOISTS 1 I BRIDGING AND/OR BLOCKING TO JOIST(TOE-NAILED) 2-8d EACH END d!:bj%MO !ri D HVAC T U^; LiI iE ____ I ' BLOCKING TO JOIST(TOE-NAILED) 2-8d EACH END li, I i BLOCKING TO SILL OR TOP PLATE(TOE NAILED) 3-16d EACH BLOCK LEDGER STRIP TO BEAM(FACE-NAILED) 3-16d EACH JOIST TING DEFLECTION i 1 JOIST ON LEDGER TO BEAM(TOE-NAILED) 3-8d PER JOIST I I BAND/RIM JOIST TO JOIST(END-NAILED) 3-16d PERJOIST 1 II 1 i BAND/RIM JOIST TO SILL OR TOP PLATE(TOE-NAILED) 2-16d(1 PER JOIST I h' ! I I ROOF SHEATHING JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING 1 1 STRUCTURAL PANELS 3 4"CSX PLYWOOD 10d 3"EDGE 6"FIELD F I I 1 DIAGONAL BOARD SHEATHIMNG 1"X6"OR 1"X8" 2-8d PER SUPPORT F-- _ ____ _ ___ __ z I NEW( )7.25 v � I � DIAGONAL BOARD SHEATHING 1"X10"OR WIDER 3-Sd PER SUPPORT LL, LV LUS )SIST ED XISTING ' _ _ i CEILING SHEATHING c I JOINT DESCRIPTION NUMBER OF NAILS NAILSPACING i ___>_ 1 o I GYPSUM WALL BOARD 5d COOLERS(3) 7"EDGE/10"FIELD o — �.- 4 (2)7.25 LVL(FL `. -------------------- I WALL SHEATHING z w ' DRYER VENTS JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING o _ _ m i IN EXISTING LOCATION STRUCTURAL PANELS 5/8"CDX PLYWOOD lOd 4"EDGE 8"FIELD GYPSUM WALL BOARD 5d COOLERS(3) 7"EDGE/10"FIELD m DIAGONAL BOARD SHEATHIMNG 1"X6"OR 1"X8" 2-8d PER SUPPORT I I ' I r DIAGONAL BOARD SHEATHING 1"X10"OR WIDER 3-8d PER SUPPORT oz IS FLOOR FLOOR SHEATHING =o I I- FLOOR > , w I T r i XT'G , i . o • i > I' "� YUPPLY JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING 1 ST FI �R I 1 — - . 1 STRUCTURAL PANELS 3 4"CSX PLYWOOD 8d 6"EDGE 12"FIELD ' 1 t v I ^ Lo j 1 STRUCTURAL PANELS GREATER THAN 1" l Od b"EDGE 12"FIELD PLAN DIAGONAL BOARD SHEATHIMNG 1"X6"OR 178" 2-8d PER SUPPORT TRUE ' DIAGONAL BOARD SHEATHING 1 N10"OR WIDER 3-8d PER SUPPORT NORT �, NEW EXHAUST ' EXISTING DECK FRAMING NORTH z TO REMAIN AS IS I I O I I cn ', I I , 0 I I n .__! I I TYP. FRAMING NOTES I o 1 I o 1N(2)7,25 VL FT ' X i =-- -- o ! - - 1 IIXT'G AL LUMBER IS TO BE NO.2 OR BETTER DOUGLAS FIR LARCH(N)WITH THE FOLLOWING z 1 I L ! IST FLOOR MIN SPECIFICATIONS co 1 x , ?UPPLY XT'G FL i E z E 'G(3 X8 B M(L W) _ _ I i Fb=825 PSI I , Fv=95 PSI LLJ Fc perp=625 PSI Q I I I I E= 1,600,000 PSI Z _U I i EXISTING 2 x 8 FLOOR JOISTS > I I W z 1 , ALL PARALLAM(PSL)LUMBER TO HAVE THE FOLLOWING MIN SPECIFICATIONS = 1 ID IF ( El. PAP L t Fb=2,900 PSI Cn w ' I Fv=290 PSI Lu ' - -- -- -- -- -- -- I - - -- = - ------------- i Fcperp=760PSI z U + - - - - ------------- 11 IF 1 I E=2,000,000 PSI Z Q �— z ' 1 - ------------------------ y.1.,.... .---...-----------------............................... I — F T -L EXT'G i ALL MICROLLAM(LVL)LUMBER TO HAVE THE FOLLOWING MIN SPECIFICATIONS O Lv Z Q 1STFLOOR I i � m w � SUPPLY I 1 Fb=2,600 PSI ''nn I I I 1 I Fv=285 PSI V O Fc perp=750 PSI � Q O E=1,900,000 PSI W = 0 1 1 1 1 u- .� EXISTING DECK FRAMING ALL PRESSURE TREATED LUMBER IS TO BE MCQ NO.2 OR BETTER YELLOW SOUTHERN PINE ♦ a Q I t i i TO REMAIN AS ISQ- t I I 1 I Fb=975 PSI O I I t I I 1 Fv=90 PSI 1 ' EXISTING SLAB ON GRADE I t Fc perp=660 PSI E= 1,700,000 PSI I I 1 — t ALL TJI'S IS TO BE 230 ¢ o ' ' I `.................................................................... ALL BEAMS FABRICATES WITH MULTIPLE LAMINATED VENEER LUMBER BOARDS ARE TO i BE NAIILED/BOLTED AS PER MANUFACTURER'S SPECIFICATIONS ALL STRAPS,CONNECTORS,PLATES,BOLTS,NAILS ETC,ARE TO BE GALVANIZED OR STAINLESS STEEL. ��FtED ARG,y i UNLESS OTHER WISE NOTED, U�`' �MSE Loo � t I 1 i ALL DESIGNATED CONNECTORS,STRAPS,ETC TO BE SIMPSON(UNLESS OTHER WISE NOTED)+INSTALLED PER MANUFACTURER'S SPECIFICATIONS. =e`: ________________ I ALL WALL SHEATHING TO BE 15/32 INCH APA RATED EXPOSURE 1 PLYWOOD+SHALL BE NAILED WITH 10D COMMON NAILS 6"O,C•EDGES AND 12"O•C.FIELD ` ---------------'----- --------- -' 04329 ALL BOLTS NUTS AND WASHERS ARE TO BE HOT DIPPED GALVANIZED UNLESS OTHERWISE NOTED. '`OF N `( I CONTRACTOR TO INSTALL SIMPSON HURRICANE TIES+STRAPS AS PER LOCAL BUILDING CODE, Seal I I LOOK STRUCTURAL PLAN STRUCTURAL + MECHANICAL NOTES A- 101 4 1,0" 2 INTERIOR DOOR SCHEDULE o DOOR PANEL DOOR DETAILS REMARKS - N w NO, TYPE HMVR FINISH MATERIAL QTY, WIDTH HEIGHT THICK. HEAD JAMB SILL PTD WOOD PTD WOOD FLAT - PAINTED WOOD �= z FLAT PANEL LOUVER DOOR FLAT PANEL I ' DO1 A a Paint Wood 1 2'8" 61'± 13 4" DTL 3 DTL 3 SIM DTL 4 DOOR DOUBLE DOOR I ct D02 B Paint Wood 1 2'b" 6'8"± 13 4" DTL 3 DTL 3 SIM DTL 4 0 0 D03 A n Paint Wood 1 2'8" 6'8"± 13 4" DTL 3 DTL 3 SIM DTL 4 •- = o LL U m � D04 A Wood Wood 1 2'8" 6'8" 1 3 4" DTL 5 DTL 5 SIM DTL 4 SIM Q D05 C Wood Wood 2 2 1'10" 6'8" 13 4" DTL 3 DTL 3 SIM DTL 4 —PTD WOOD - PTD WOOD PTD WOOD N Q - - - - - - - - - - - - - - - - DOb A Wood Wood 1 2'b" 6'8" 13 4" DTL 3 DTL 3 SIM DTL 4 FRAME FRAME FRAME CL w D07 A Paint Wood 1 2'8" b'8" ± 13 4" DTL 3 DTL 3 SIM DTL 4 TYPE A TYPE B TYPE C O Lu EXISTING 0 00 OWER jLu j 2 INTERIOR DOOR SCHEDULE + ELEVATIONS Q SCALE: 1/4 = IV00 LINE OF EXISTING STRUCTURE I : LINE OF EXISTING STRUCTURE BEDROOM 3 SOLID PAINTED WOOD PANEL U EXISTING WOOD \ / _ j LOUVER DOOR MAY OCCUR. NEW GYP GEILING+FRAMING I NEW GYP GEILING+FRAMING / SEE DOOR TYPE - -_ __= i^ CASING OR FRAMED OPENING MAY BLOCKING AS REQ. 0 HEADER AS REQUIRED l OCCUR BEYOND 3/4' _ o TILE ON THINSET MAY OCCUR POCKET DOOR HARDWARE - GYP BD,TYP,MRGWB AT TILED WALLS - PAINT INTERIOR tT a I = CEMENT BD AT SHOWERS VINYL FLOOR ON EXISTING SLAB �„ ji; POCKET BLACK w (EX)H20 (EX)H20 I j _ - _ i PTD CONC•MAY OCCUR BASEBOARD BASEBOARD B.O.F,O,HEAD B.O. EA CO L" L / / - - - - -- I- - -------- I - - - - STEP - I - - - - - - - - - - - - °� 68A.F.F. %// � w / M CID6 8 A.F.F. m r -- --' - - - / / % / SOLID PAINTED OR o _ i r / ' '� (EX)H20 (EX)H20 � � PTD.WOOD TRIM �' ' WOOD FLAT PANEL CLST I I BASEBOARD '1----------'-- ------- -----------____-- / PTD•WOOD TRIM / POCKET DOOR BASEBOARD I --------- - --i I PTD DOOR STOP AT PTD DOOR' - , I _ / / J --- --- ' INST L NEW EXHAUST CLST � I I -___._-_______._ ____.___ _. _____._ j j SOLID PAINTED WOOD PANEL - / LOUVER DOOR MAY OCCUR, FAN To Roo�gLL 2 I / SEE DOOR TYPE EXISTING WOOD { EXISTING TILE BEDR�c oM2 - — ----- -- — TYPICAL DOOR HEAD DETAIL TYPICAL DOOR SILL DETAIL POCKET DOOR HEAD 0 DETAIL EXISTINc�wooD SCALE:T= I T' 4 SCALE; T= 1'0" 5 SCALE:T= 1'0" I ' J { 1 1/2" 3/8 BEDROOM 1 � EXITING WOOD SHIM AS REQ I � NEW VANITY - II jF , Lu -- z PTD,WOOD TRIM PTD,WOOD TRIM HALL 1 EXISTING WOOD -- --- -- -- ------------ --- _ �� / IBATH ` J - - _ - ------ CLST _ ` ---- r� r REPLACE, I — - EXISTING NEW OORTILE - --- -- - --- -- - ------- 1 /� - j _\ 1 HARDWARE__- (TO MATCH - ---- -------- I - j "' KITCHEN ---------------- -- ® (EX)H20 j ---- -- ----------- -- ------- BASEBOARD - - -- - SOLID PAINTED OR WOOD -1 SINGLE PANEL Q 1fl POCKET DOOR o CN REPAIR EXISTING WOOD FLOOR PTD.WOOD TRIM NEW 36' -- XINNG D CK GYP BD. I I; INDUCTION DINING RM. _ xISTINGWoo REPAIR EXISTING BRICK I 1' i'I:I RANGE EXISTING WOOD POCKET DOOR JAMB DETAIL f;; I - SCALE:T= IT' WALKWAY To BE LEVEL �;; 'i ., 13 KITCHEN EXISTING WINDOW EXISTING WOOD REPAIR CRANK MECHANISM ;I +i --T MATCH EXISTING !� NEW SADDLE TO EXISTING �, +I SINK FLOOR STAIN 1 NEW H2O =_-____ - ------------------------ ---- -- --- ---- i Lu NEW 36"FRIG :Y :- 1 ; BASEBOARD c I ----------------- Lu - - -------- - f '' - - - - ------------- - - - -— -- -- Lu _L7 _ z NEW MILLWORK- CLOSET _ = j I I;I I i I° - ---------------------- - ----- -- ; j o 0 - - - - NEW PTD WOOD STAIR W/WOOD HANDRAIL+ N N PTD WOOD STOCK BALUSTERS NORT / 13 RISERS @ 7.375"±-12 TREADS @ 10" TRUE (COMPLIES W/2015 IRC R311 J5) --------- -- -------------------------------------- NORTH WING RM, EXISTING WOOD ENTRY/SITTING RM. EXISTING WOOD D \ 5 \ W 1 �' i II A100 III I MATCH EXISTING j V SADDLE TO EXISTING 1 Z z FLOOR STAIN W (EX)H20 BASEBOARD Z O (EX)H20 W cC �- BASEBOARD j - --- -- ------ --- -- --- j C� w O, U j Zzr � - - - - - - - - - - - - - - - -- --- -- - - - - J OOz zOo - -- ----- --- = w U_O U (EX)ELEC UP BASEBOARD -- / V- LO 0 z EXISTING HOT TUB -- ------------ a O (EX)ELEC I EXT'G HVAC j - ------- / + tom- 3 cn BASEBOARD EQUIP, EXT'G HVAC EXT'G HVAC ;' - z U EQUIP. EQUIP. -- ---- -- SUN RM. EXISTING WOOD I ' m � a � '(EKED ARC 18 - - I 16 Q� 290 O�17 jj 0_6 REMOVE WINDOW FILMI RESIDUE OFF / / / 0 O j EXTERIOR OF WII)IDOW / i/ Seal � FIRST FLOOR CONSTRUCTION PLAN i A-102 SCALE: 1/4"= 1'0" 0 z H 0 J = ow � ¢ Q �, � w J z N I W o z � cli EXISTING ROOF TO REMAIN • I I 0 I I I � I w w I W �- I � � I � w r. W 0 I I ENCLOSE+INSTALL - -- - - - NEW BATH EXHAUST NEW BATH EXHAUST -- UP TO ROOF OPEN TO BEDROOM BELOW „ B�.ME�ADJ1*-7 AGr' - - --- -- - EXISTING SKYLIGHT - j - EXISTING WOOD ABOVE ` --- -- - - - -- --- --- - EXISTING ROOF TO REMAIN -- --- ` - -- -------- j -- --- EXISTING SKYLIGHT I ------- -- _ -- n1 Y/ I � V - I ROOF TO REMAIN I I ENCLOSE+INSTALL - - -- I, NEW KITCHEN STOVE EXHAUSTI I - - - -- - -- --- ' I I, UP TO ROOFul I - - - -- - -- - - I - — - - - - - ® E N NEW KITCHENEXHAUST I I I , ABOVE SKYLIGHTABOVE SKYLIGHT - -- I EXISTING ROOF TO' --- - -- - - - -_- -- - REMAIN EXISTING SKYLIGHT EXISTING SKYLIGHT', - -- --- -- I I -- W PATCH WALLS+A EQ'D z • FROM BUILT IN+C SET DEMOLITIONco I - - ---- -- - -- — -- IIjII•I II ❑• - - I, - II'IjI I I I I IIIj i I ----_-. _----------- --- ---------------- ----- -- -------- - -�------------- - -----'--I-- I - - - i I �vm=uZ� �0 wST�� GE ISTI66 WOOD o PLA ,H_Op F?oyy aT�� �R �tUUz� ai � E YLIGTEXNG S EXISING SKYLIGHT NORT B B R. Ti HAOVE AOVE EXISTING SKYLIGHT EXISTINGSKYLIGHT EXISTING ROOF T W O Lu Lo WQO OEl w J W O 1z� _ 9 O + w� 0- EXISTING ROOF TO REMAIN FtED ARC E L Li ` 32 4A � Seal . I j SECOND FLOOR CONSTRUCTION PLAN j 2 ROOF FLAN A- 103 SCALE: 1/4"= 1'0" SCALE: 1/4"-- 1 V Wall Phone TV Location o -- N� -HDMI as Required N b -CAT 5&CAT 6(2 each) -Cable - z Q -Power j TV Box Location 0 ow NB -HDMI as Required V o ------ -CAT 5&CAT 6(2 each) -Cable Q w -Power Ed Q Q I I -Inferred Eye IIZ LLi 1 I 0 _v------------------------ Ethernet-2 ports � 00— z , I I I I each location w o 01 I I I I ❑ w v a' Siren zLq r ,l I I I I HD Heat Detector CINO CRAWL SPACE '" I ' CRAWL SPACE LJ , I OS3 i i ® Water Detector Keypad AL(AV) k Audio/Video Alarm Ke ad I I I 1 I I AL(A)❑k --� Audio Alarm Keypad I I I 1 i i ©D Motion Dector I I 1 1 I Volume Control 0 sP Recessed Ceiling Speakers 0 OS3 Exterior Recessed o I I I I s Ceiling Speakers I I I I w �2 LU Bookcase Speaker . `I_�, �ruyriJll- - C_S DM-'-- -'IIIF -__IIIII¢_.. - --A-{I-._—'-•LI..---(='}°±- -Ir- J—�\II;II`. --'.I�L -`"�CIIIIIfII Lj __---------$---"±---C_-_'-L'-,A N-�-G•--_• =—H-_-^T i�I-_=8---;1�-\- ±- •• I iII;,I'1,IIIIIiI;IiII � ----- I I ITII I ---- - -�-^�'- - --AT--H- ---.-------R-. --�r- I,i;{tII,irIIiI,,,,IIII , "I❑S�.D, T"t 0 Sub-WooferEXISTING EXTERIOR SCONCE w --------------- ------------------------ -------------- --- --- Recessed Wall Speaker r r oNzwa` or o r------------------ - - - - - - - - - - - - - - Wall Mounted,Sp aker ------------- Exterior Wall SP Mounted SpeakerHT,-7'3",A AA A Planter Speaker - - - - - — - - - - - - - _ NEW TV SUPPLY-------------- Thermostat CLING,HT. 7'11 ECIROOM REC ROOM Junction BoxPt r p Ptd.Gyp. Duplex Outlet (IF NOTED TO BE A OFCIA," a SWITCHED-TOP OUTLET) Quad Outlet :CRAWL SPACE q CRAWL SPACE r--- Ground FaultGFI Interrupt Outlet J �WP Exterior Outlet(waterproof)� Exterior Recessed______ -••-_- RWP _ - s- Waterproof Outlet o -e Dedicated Outlet -0USBCM USB Outlet ----------- Duplex Floor Outlet --------------------- ------- - Gas Connector - --- a Wire ld w/Power&Data EXISTING (See Low Voltage or# f Outlets/Provide ------- ---- - ------ AC r I Receptacle Everyl2") -� HV- EQUIP$ _ Smoke/CarbonmonoxideDetectorNIS BULE I --------.--.------ DOS3 I CI BAT ------------------ wPtd.Gyp. SEWER Ptd,G EJECTOR PUMP _C Smoke Detector Tied Into Fire Alarm yp' A LN T, Lutron Home Works Switch 7'1 VESfBULE S ----3 GFI --- - - - - - - - - New Double Pole Switch Jamb Switch +CLNG.H .I1 A CM A Recessed Ceiling Fixture SID { —L HALL Exterior Recessed A --------------- Pfd,Gyp' r--- Ceiling Fixture Surface Mounted QS3 Ceiling FixtureLU os1 WASHER RYER UNIT Pendant Mounted Fixture - - - - - - - - - - - - -- - - - - - - - - - I I Jr_A 052 III1'I,IIIIi'II ',IiIIiiII'II --- --- PANTYr'I ,- I ----------------------- -I --I R-Y_E iR_-UNIT NIT — Ceili ng Fa- n WASHER HIM- $CLNG,HT.-7'1 LU - ` PALRY Wall Mounted Fix t—u re - -- - � O 0Closet/Millwork FixtureLAUNDRY LAUNDRY Ptd, ----• Ptd,Gyp. Picture/art Light EPP�RM LAEUUEN U ERIG EANER UNIT TRUE Recessed Linear Ceiling Fixture NORT A NORTH23 CRAWL SPACE CRAWLSPACE Wall Mounted Fixture EIRWL L _ Recessed I LightMECHANICAUSTORGE - - - - - - MECHANICAUSTORGE P Path Light•------_ GFI FI -, - 0'-0" Ceiling Height Above Floor LOS3 -06S3 Supply Grille Return Grille EXIS ING BOIL El Access Panel W + OS3 OS3 HOLDING T EXISTING STORAGE SS Self Switching Fixture - ELECTRICAL PANEL W L7 Centered wc0 L1 ------------------ U in space -------------- ------- i ------------ -------- ----------------------------- w Z RELOCATED = 0 "1-EXISTING BASEMENT SWITCH+OUTLET m SUB PANEL LOCATIONS DIAGRAM n QQ 11/2'±TO WIDEST DEVICE 0 LU z Uj KEYPAD,PHONES& DOOR CASING wm -THERMOSTAT--SWITCH. SLAB ON GRADE SLAB ON GRADE -Hzo�al--OUTLET o (May Occur In Base See evs)SEE ELEVATIONS FOR GENERA. D qLOCATIONS AND SPECIAL EQUIPMENT E L SEE RCP FOR EQUIPMENT AT CEILING L----------------------------------- AllLightsShallBeOnDimmers-ElectricianTo Coordinate Dimmer Types W/ Proper `------------------------------------------ I Loading&Light Fixtu 32 All Smoke/carbon Monoxide Detectors Shall - - C � Seal be installed per code BASEMENT REFLECTED CEILING PLAN 2 BASEMENT ELECTRICAL FLAN A-200 SCALE: 1/4 - 1 0 SCALE, 1/4 - 1 0 -a Wall Phone TV Location --O -HDMI as Required Q -CAT 5&CAT 6(2 each) 0 ! I , -Cable F-- - Q I -Power TV Box Location 0 0 j I NB -HDMI as Required U o ,w m l -CAT 5&CAT b(2 each) Lv Q I j -Cable Q FLU w - - - -- - - - - - - - - Power QQ - - - -Inferred Eye U w 1 s - j j Ethernet-2 ports at -t z N each location W o jn 0 Siren IN H D Heat Detector I I I Water Detector j I i AL(AV) Qk 1 Audio/Video Alarm Keypad I j I AL(A)Qk 1 Audio Alarm Keypad U BEDROOM 3 0 EXISTING GYP ! j No BECRK TO DROOM131NG j I ©D Motion Dector NO WORK TO EXISTING I I ELECTRICAL I I VD Volume Control O LIGHTING OR SWITCHING j i I I sP Recessed Ceiling Speakers 0 j Exterior Recessed cn o Ceiling Speakers �u w w I j I j SP Bookcase Speaker w I I I I SW Sub-Woofer W Q WSP Recessed Wall Speaker ^ 0 � Z CLST j =___, CLST ____-� _ Wall Mounted.Speaker - 1 -- Exterior Wall II I CLST I - _ j -- - - --Jam= .T --- - ---- ESP Mounted Speaker j CLST I sP Planter Speaker EX A ST - _ � FA EXISTING GYP `,! I I ; B. 2 HALL 2 ', ! j -__-- --__-- - - _----- O NO WORK TO EXISTING I TO EXIS ELECTRICAL TV ELECTRICAL T Thermostat BATH 2 j — � j -- -- --- - -C EXISTING GYP ; ! BEDROOM 2 j ! BEDROOM 2 --- ----- --- - ' _ � Junction Box EXISTI G GYP NO WORK O EXISTING LWI BINE NE WITCH _ I _� N9 W00 EXISTING I ! !- ---ELECTRICAL - - Duplex Outlet I J STING WITCH BANK i LIGHTING OR SWITCHING I- --- - --- --- _ _ (IF NOTED TO BE U� �� I SWITCHED-TOP OUTLET) BEDROOM 1 � ! � BEDROOM 1 ��� I � - ---- Quad Outlet EXISTING GYP I NO WORK TO EXISTING GFI Ground Fault NO WORK TO EXISTING Interrupt Outlet I ELECTRICAL I ---__-- ------- - - -- LIGHTING OR SWITCHING I � - - j �WP Exterior Outlet(waterproof) - - � Exterior Recessed RWP Waterproof Outlet 0 I HALL 1 EXISTING GYP HA 1 y -- -- __- Dedicated Outlet NO WORK TO EXISTING --- - - --- _-- -❑USB USB Outlet ELECTRICAL - - I ; BAT{ 1 ( _ Duplex Floor Outlet 4CLST IrT � CLST WORK TO EXISTING Gas Connector ELECTRICAL =_= Wire Mold w/Power&Data — _-Lj (See Low Voltage For of outlets/Provide Receptacle Every 12`) Smok arbonmonoxide Detector Ne/C UST - - - - - - - - - - -- - i - -- ------ N REPLACE-= - 111 -- Jill C_ i U' INEW_ ! - - -- -- SD ¢ o - " . ;�°1I Smoke Detector Tied Into Fire Alarm N EXISTING=_�� C ' I I,lii' �- NEF,�NnEIA =gal RANGE E HOD== ( EXISTING DECK-- Lutron Home Works Switch DINING RM, '''��'' ' I DINING RM. --- N6woRx-To-ExrsT� ---- EXISTING GYP I EW GFI NO WORK TO EXISTING -- -- New Double Pole Switch KITCHEN NO WORK TO EXISTING I Ii PER CODE ELECTRICAL ----- - -ELECTRICAL �S I i!I ! KITCHEN C Jamb Switch EXISTING GYP LIGHTING OR SWITCHING --- --- __ -_ NO WORK TO EXISTING j j; __ _ ---- Recessed Ceiling Fixture Exterior Recessed LIGHTING OR SWITCHING it T — - ' I I ry n -- -- --- -- ---- --- --- � Ceiling Fixture NEW OUTLETS _ NEW FRIG ---- ' -_ Surface Mounted ,a t I ---_ - - ----- '- Ceiling Fixture . == - - - - f �•n F• w -- - - - - - - - - - - I NEW GFI II - -- --- - Pendant Mounted F 7=4_ PER CODE - --_---------- ------- Fixture -- - j — - -- --- z _ - - - - - - - - ---- - - - j all, - - - - - -- --- -- Ceiling Fan I j m EXISTING - - - - - _ 0 0 --- --- Wall Mounted Fixture N o COMBINE NEW - - - ® Closet/Millwork Fixture W/EXISTING SWI - - - - - - -- Picture/art light • - - - - - - - - ---- --- PLAN - - - - - - - - � - - - - -- -- -- --- TRUE l - - I i __ Recessed Linear Ceiling Fixture NORTFJ; - -- --- --- NORTH I • - - - - - - ------ - Wall Mounted Fixture - - - - - WING RM, I WING RM. I ❑ RWL -- - - - - -- EXISTING GYP ENTRY/SITTING RM, i --___ ____ Recessed Wall Light ENTRY/SITTING RM. - - - - - I _ -- No WORK TO EXISTING EXISTING GYP NO WORK TO EXISTING ELECTRICAL LIGHTING OR SWITCHING NO WORKTO EXISTING --- ----- pL NO WORK TO EXISTING ELECTRICAL Path Light j LIGHTING OR SWITCHING 0'-0" Ceiling Height Above Floor Supply Grille W l (� I ( I ------ --- ---- --- � Return Grille z + --- ® Access Panel W I - - ----- - - SS Self Switching Fixture z LU l I— ----- -- -- ---- -- - • _ Fixture Centered � w C o I j zzr w I � _ In Space �-- j I v --- - W l I - - --- --- SWITCH+OUTLET = m "J LOCATIONS DIAGRAM 0 OO U I j - --- - 1 1/2"±TO WIDEST DEVICE W = Q - i I -- ------ _. ---------- -- 03 = �� U EXISTING HOT TUB - -- 'f' �r III___ __- -_.__ KEYPAD,PHONES& DOOR CASING ,_ o 1 I EXT'G HVAC ---- -- Z • I � EQUIP. � --- ---- - -THERMOSi�;T - -- EXT'G HVAC EXT'G HVAC I U EQUIP. EQUIP. -- --- -- SWITCH.- ._ .- . l SUN RM. I - ---- --- SUN RM. I _ _ — -----�,, �_ Q EXISTING GYP I ; --NO TO EXISTING NO WORK TO EXISTING I -OUT1T--Horizontal. I I ELECTRICAL y N Q LIGHTING OR SWITCHING (May Occur In Base See I � N � j I SEE ELEVATIONS FOR GENERAL ¢ DER ARC LOCATIONS AND SPECIAL EQUIPMENT I �5 EE LOp I I J SEE RCP FOR EQUIPMENT AT CEILING � I „ I i j j * s*= -All Lights Shall Be On Dimmers-Electrician To - - - - - - - - - - - - - - - - - - - - - i- - - - - - - - - - - - - - - - - - - - - - - I - - - - - Coordinate Dimmer Types W/Proper �4329 j Loading&Light Fixture OF y� r7F -All Smoke/carbon Monoxide Detectors Shall Seal j I i be installed per code FIRST FLOOR REFLECTED CEILING PLAN i 2 FIRST FLOOR ELECTRICAL PLAN i A-201 SCALE. 1/4- 1 0 SCALE: 1/4 = 1 0 --a Wall Phone o TV Location 0 -HDMI as Required N w -CAT 5&CAT b(2 each) -Cable V z Q -Power JLjj TV BOX Location NB LLJ HDMI as Required U o -CAT 5&CAT b(2 each) Lv -Cable Q W -Power Q Q -Inferred Eye a. LL; Ethernet-2 ports at 0_ `o N each location w o a Siren N HD p.Heat Detector `� ® Water Detector AL(AV) Qk -I Audio/Video Alarm Keypad AL(A)❑k —1 Audio Alarm Keypad V ©D Motion Dector VO Volume Control 0 sP Recessed Ceiling Speakers o ' Exterior Recessed to o Ceiling SpeakersIII �2 w SP Bookcase Speaker w r U� co CIO SW Sub-Woofer W o Li Cl-� Q WSP Recessed Wall Speaker o i d Wall Mounted.Speaker w Exterior Wall ESP Mounted Speaker NEW BATH EXHAUST SP Planter Speaker UP TO ROOF TV EXISTING SKYLIGHT (� Thermostat BEDROOM 2 MEZZANINE ST GE BEDROOM 2 MEZZANINE ST AGE Junction Box EXISTING GYP, NO WORK TO EXISTING I—, — — —I Duplex Outlet NO WORK TO EXISTING ELECTRICAL (IF NOTED TO BE LIGHTING OR SWITCHIN SWITCHED-TOP OUTLET) hk Quad Outlet GFI Ground Fault Interrupt Outlet ' :IOWP Exterior Outlet(waterproof) Exterior Recessed w i � RWP Waterproof Outlet o _0 Dedicated Outlet U — DUSB USB Outlet Duplex Floor Outlet Gas Connector Wire Mold w/Power&Data (See Low Voltage For#Of Outlets/Provide NEW KITCHEN STOVE EXHAUST Receptacle Every 12') UP TO ROOF B Smoke/Carbonmonoxide Detector N SD Smoke Detector Tied Into Fire Alarm in 0 Lutron Home Works Switch New Double Pole Switch us Jamb Switch EXISTING SKYLIGHT EXISTING SKYLIGHT Recessed Ceiling Fixture Exterior Recessed — — Ceiling Fixture , I Surface Mounted _ Ceiling FixtureLU Pendant Mounted Fixture W o Ceiling Fan EXISTG GYP, ST GE I - m o NO WORK 0 EXISTING 0 LU LIGHTING 01T SWITCHING ST9 GE 0� Wall Mounted Fixture o NO WORK T�EXISTING o Closet/Millwork Fixture CIO l ELECTRICAL Picture/art Light PLAN EXISTING SKY EXISTING SKYLIGHT — Recessed Linear Ceiling Fixture NORT ,TRUE NORTH Wall Mounted Fixture ❑ RWL Recessed Wall Light $PL Path Light I � 0'-01, Ceiling Height Above Floor ® Supply Grille Liu Return Grille V C9 � ® z z Access Panel W U SS Self Switching Fixture � w 1 1.1J LO p Fixture Centered w U ❑ j In Space Z Z< r:: J O � >- �z SWITCH+OUTLET = m o LU 00 LOCATIONS DIAGRAM Q � �, U_ Q 1 1/2"±TO WIDEST DEVICE W = - - � _ SOU KEYPAD,PHONES& + U U w I - DOOR CASING o U-) w --THERMOSTAT — — — -" -- - - Z U -WITCH. LL L.L LPL I Q � OUTZ€ Horizontal.— .� — .v,_Q = o (May Occur In Base See Q evs -\--ti. m �; it a SEE ELEVATIONS FOR GENERAL LOCATIONS AND SPECIAL EQUIPMENT � ,��RED Ar? SEE RCP FOR EQUIPMENT AT CEILING \� EEL -All Lights Shall Be On Dimmers-Electrician To Coordinate Dimmer Types W/ Proper (N _ Loading&Light Fixture 04329 OQ" c -All Smoke/carbon Monoxide Detectors Shall seal be installed per code SECOND FLOOR REFLECTED CEILING PLAN 2 SECOND FLOOR ELECTRICAL PLAN A-202 SCALE: 1/4= 1 0 SCALE: 1/4= 1 0