Loading...
HomeMy WebLinkAbout50041-Z ��o�S1�FF01k o Town of Southold 12/13/2023 P.O.Box 1179 53095 Main Rd Southold,New York 11971 'vCX17-tXU�r . CERTIFICATE OF OCCUPANCY No: 44813 Date: 12/13/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 640 Chestnut Rd, Southold SCTM#: 473889 Sec/Block/Lot: 59.-3-16.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/2/2023 pursuant to which Building Permit No. 50041 dated 11/17/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar on existin single-family dwelling as applied for. The certificate is issued to Siempre Trt II of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50041 12/11/2023 PLUMBERS CERTIFICATION DATED lei Auth riV Signature TOWN OF SOUTHOLD �osuFFQ� BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 60041 Date: 11/17/2023 Permission is hereby granted to: Siempre Trt II 53 Griffing Rd East Quogue, NY 11942 To: install roof-mounted solar on existing single-family dwelling as applied for. At premises located at: 640 Chestnut Rd, Southold SCTM #473889 Sec/Block/Lot# 59.-3-16.3 Pursuant to application dated 11/2/2023 and approved by the Building Inspector. To expire on 5118/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 B Iding Inspector SO(/Tyol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 'Ph Jamesh southoldtownny.gov oUNTN, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Alexandra Wagner Address: 640 Chestnut Road city:Southold st: New York zip: 11971 Building Permit#: 50041 section: 59 Block: 3 Lot: 16.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Venture Home Solar LL Electrician: Jason Sampogna License No: ME-60556 SITE DETAILS Office Use Only Residential x Indoor x Basement Service Commerical Outdoor x 1st Floor Pool New x Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200a Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200a A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect 60a Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 7.70kw DC / 5.51 kw AC Roof Mounted Solar Energy System with 19 Panels [ML-G10+405 Modules], 19 Micro-Inverters[IQ8PLUS-72-2-US], 1 Enphase IQ Combiner 4 Panel Notes: [X-IQ-AM1-240-4], 1 60amp disconnect [Fused] Inspector Signature: Date: December 11, 2023 640 chestnut rd 0FS0Uly�loGGs�ncc - # # TOWN OF SOUTHOLD BUILDING DEPT. �ycouto, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL lar REMARKS: 60 �� 3L d4&�7 DATE INSPECTOR UE SOUTyolo -- # # TOWN OF SOUTHOLD BUILDING DEPT. coum 0 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION n �y [ ] PRE C/O [ ] RENTAL REMARKS: 7 DATE INSPECTOR MELD INSPECTION REPORT DATE COMMENTS �v O FOUNDATION (1ST) ---- -- ------------------------------------ C FOUNDATION (2ND) z o O ROUGH FRAMING& y PLUMBING ' INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS rb — fl3 t w3 �1 Ge.��-• Z m b N z x x d b =�gUFFO(r�OG��� TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631)765-9502 https://www.southoldtowM.gov Date Received APPLICATION FOR BUILDING PERMITIno E �jEJVE For Office Use Only PERMIT NO. Building Inspector: NOV - 2 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an gui9dia�g IDepartment Owner's Authorization form,(Page 2)shall.be completed: ° Town of Southold Date: OWNER(S)OF PROPERTY: Name:Alexandra Wagner_ _ SUM#1000- Project Address:-640 Chestnut Rd,-Southold,,-New York_11971 Phone#: 917 .353-9343 _w u ail:alexwagq@gmail.com MailingAddress:640 Chestnut Rd, Southold, New York 11971 CONTACT PERSON: Name:Adrian Diego Mailing Address:100 Charlotte Ave. Hicksville NY 11801 Phone#:914_-214-7108 _- __ _ _ Email:permittingny@venturesolar.com DESIGN PROFESSIONAL INFORMATION:. Name:Patrick BuSsett Mailing Address:100 Charlotte Ave. Hicksville NY 11801 Phone#:914-2147049 Email:permittingny_@ve nturesolar.com CONTRACTOR INFORMATION: Name:Venture Home Solar LLC -Alex Yackery Mailing Address:100 Charlotte Ave. Hicksville NY 11801 Phone#:914-214-7108 _ w_ Email:permittingny@venturesolar.com DESCRIPTION:OF PROPOSED CONSTRUCTION El New Structure ,drdition ❑Alteration`❑�epair ❑Demolition Estimated Cost of Project: ❑Other ��` U 1Zoc'X mOyn-�X 5o\ct Sv�s'rcc��c��:an $ ��,y�®. 00 Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property: Intended use of property:Resldentlal Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ©No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code."APPLICATION IS HEREBY MADE to the Building Department for the issuance of a.Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building.code, housing code and regulations and to admit authorized_inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(pr, nnam :Adrian Diego ®Authorized Agent []Owner Signature of Applicant: Date: 10.30.2023 STATE OF NEW YORK) SS: COUNTY OF ) Adrian Diego being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Authorized Agent - Venture Home Solar LLC (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 30thdayof October 2023 _ STEPHEN JOHN LIASEX of Public rAlexandra TpttY PUBLIC,STATE OF 1 YORY• �tcation No.02LU6407287 Q �mSugDa�untq PROP RTY OWNER AUTHORIZATION re the applicant is not the owner) Wagner residing at 640 Chestnut Rd Southold NY 11971 do hereby authorize Adrian Diego -Venture Home solar toapply on my behalf to the Town of Southold Building Department for approval as described herein. 10.30.2023 Owner's Signat e STEPHEN JOHN LUISE JR. Alexandra Wagner NOTARY PUBLIC,STATE OF NEW YORK Print Owner's Name Registration No.02LU6407287 Qualified in SuffpA Countr My Commission Expires i Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, Alexandra Wagner residing at 640 Chestnut Rd, (Print property owner's name) (Mailing Address) Southold, New York 11971 do hereby authorize Adrian Diego-Venture Home Solar LLC (Agent) to apply on my behalf to the Southold Building Department. 4gW 10.26.2023 Ww ner's Signature) (Date) Alexandra Wagner (Print Owner's Name) o��SVFFOtlr BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD ti z Town Hall Annex- 54375 Main Road - PO Box 1179 Southold New York 11971-0959 oy�01 �a0�� Telephone (631) 765-1802 - FAX (631) 765-9502 roaerr(a)_southoldtownnv.aov— seand(@-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 10.30.2023 Company Name: Venture Home Solar LLC Electrician's Name: Jason P. Sampogna License No.: ME-60556 Elec. email: permittingny@venturesolar.com Elec. Phone No: 914-214-7108 01 request an email copy of Certificate of Compliance Elec. Address.: 100 Charlotte Ave Hicksville NY 11801 JOB SITE INFORMATION (All Information Required) Name: Alexandra Wagner Address: 640 Chestnut Rd, Southold, New York 11971 Cross Street: Phone No.: (917) 353-9343 Bldg.Permit#: ,j email:alexwags@gmail.com Tax Map District: 1000 Section:59000 Block: 3000 Lot: 16003 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please. Print Clearly): PV ROOF MOUNTED SOLAR INSTALLATION OF 19 PANELS / 7.695 kW Circle All That Apply: ISquare Footage: Is job ready for inspection?: YES 0 NO Rough In FIFinal Do you need a Temp Certificate?: YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New ServiceE]Fire Reconnect[]Flood ReconnectElService ReconnectOUnderground 0✓Overhead # Underground Laterals M 1 FJ2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 1 Suffolk County Dept.of „Y;t Labor,Licensing&Consumer Affairs yf ak VASTER ELECTRICAL LICENSE Name JASON P SAMPOGNA Business'Name Pis certifies that-the )earer is-duly licensed VEN1 URE FOVE SOLAR LLC UHA :y the County of Suffolk License Number:ME-60.556 Rosalie Drago Issued; O5/14,2018 Ccnur�ssiorer Expires: 051OV2024 • : c alk County De t. of Labort is enising a C rises ier,Affairs SUSi.nes .'Nq. e. Plisl-COrkifieg that the -fearer is duly license CLC D8A. . ,)Y tho'CountY of s ffralk ; License Nijr�ber: K-59758 Rosals 0rago Issued: 02115/20 8 CmMnlissivncr Expires: 211/2024 fSNT RK Workers' CERTIFICATE OF INSURANCE COVERAGE ATE Compensation NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW Board PART 1. To be completed by NYS Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Venture Home Solar,LLC 718-398-22S9 100 Charlotte Ave Hicksville, NY 11801 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured (Only required if coverage is specifically 47-4266827 limited to certain locations in New York State,i.e.,a Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Metropolitan Life Insurance Company 3b.Policy Number of Entity Listed in Box 1a Town of Southold 234439 53095 Route 25 3c.Policy Effective Period: Southold, NY 11971 October 1,2023 to September 30,2024 4.Policy provides the following benefits: N A. Both disability and Paid Family Leave benefits. ❑ B. Disability benefits only. ❑ C. Paid Family Leave benefits only. 5.Policy covers: HA. All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B. Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as described above. Date Signed: October 30,2023 By:Sue y Da (Signature of Insurance carrier's authorized representative or NYS licensed insurance agent of that named insurance carrier) Telephone Number: SPU Group ContractsOmetlife.com Name and Title: Suzy Davis.State Plan Consultant IMPORTANT: If Boxes 4A and SA are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.nv.¢ov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit, PO Box 5200,Binghamton,NY 13902-5200. PART 2. To be completed by NYS Workers'Compensation Board(Only if Box 413,4C or 5B have been checked) State of New York Workers'Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed: By: (Signature of Authorized NYS Workers'Compensation Buard Employee) Telephone Number: Name and Title: Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this thrill. DB-120.1 (12-21) NEW Workers` CERTIFICATE OF 5TAtE Compeln§ation Board NYS WORKERS'COMPENSATION INSURANCE COVERAGE 1a.Legal Name Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Progressive Employer Management Company III,LLC Labor Contractor,for (718) 398-2259 leased workers to: Venture Home Solar,LLC dba:Venture Solar Electric 1c.NYS Unemployment Insurance Employer Registration Number of insured 100 Charlotte Ave Hicksville,NY 11801 1d.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,a Wrap-Up Policy) 47-4266827 2.Name and Address of Entity Requesting Proof of Coverage(Entity Being 3a.Name of Insurance Carrier Listed as the Certificate Holder) American Zurich Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"I a" 53095 Route 25 WC 10-18-880-04 Southold,NY 11971 3c.Policy effective period 4/1/2023 to 4/1/2024 3d.The Proprietor,Partners,or Executive Officers are X . included.(Only check box if all partnerstofficers inclued) all excluded or certain partners/officers excluded. This certifies that the insurance carer indicated above in box"3 insures the business referenced above in box"la"for workers'compensation under the New York State Workers' Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box 7. The insurance carrier must notify the above certificate holder and the Workers Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the Insurance carrier or its licensed agent,or until the policy expiration date listed in box 3c, whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend,extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy Indicated on this form,if the business continues to be named on a permit,Iicese or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the Insurance carrier refemced above and that the named insured has the coverage as depicted on this form. Approved by: Douglas Jones (Print name of authorized representative or licensed agent of insurance carrier) Approved by: �� � � 10/30/2023 (Signature) (Date) Title: Vice President Telephone number of authorized representative or licensed agent of insurance carrier: (480)951-4177 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) ww.wcb.ny.gov DATE(MMIDD/YYYY) A�o® CERTIFICATE OF LIABILITY INSURANCE 10/30/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT If the certificate holder Is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement On this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Katerina Cole NAME: Provident Protection Plus Incorporated acN o Ext. (973)579 6776 WC No).' . (973)579-0111 96 US Highway 206 ADDRESS. katerna.tole@ProvidentProtectionPlus.com PO Box 4 INSURERS AFFORDING COVERAGE NAIC 0 Augusta NJ 07822 INSURERA: Southwest Marine&General Ins CO 12294 INSURED INSURERB: AmGuard Insurance Company Venture Home Solar LLC,Venture Soler Electric, INSURER C: Selective Insurance Company Venture Solar Capital LLC INSURER D: NJ Manufacturing 327 Captain Lewis Drive INSURER E: Southington CT 0646 9-11 7 0 INSURER F: COVERAGES CERTIFICATE NUMBER: 23-24 Master REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMEDABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. rA TYPE OF INSURANCE INSD W VD AD *UUK POLICY NUMBER MM/DDY EFF MMMDY YY LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE �OCCUR PREMISES Eaoccunence $ 100,000 MED EXP(An one person) $ 5,000 Y Y GL202300012768 11/15/2023 11/15/2024 PERSONAL&ADV INJURY $ 2,000,000 GEN'LAGGREGATE LIMITAPPLIES PER: GENERALAGGREGATE S 4,000,000 POLICY❑X J'ECT FILOC PRODUCTS-COMP/OPAGG $ 4,000,000 OTHER: Per Proj capped agg limit S 5,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident ANYAUTO BODILY INJURY(Per person) $ B OWNED x SCHEDULED Y Y VFAU430832 08/22/2023 08/22/2024 BODILY INJURY(Per accident) S AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY /� AUTOS ONLY Per.ecGdent Un/Underinsured $ 1,000,000 UMBRELLA LIAR OCCUR EACH OCCURRENCE S EXCESS LIAR HCLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNEWEXECUTIVE ❑OFFICERIMEMBER EXCLUDED? N/A E.L.EACH ACCIDENT $ (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Commercial Auto Combined Single Limit 1,000,000 C Scheduled Auto(7) S2467549 08/22/2023 08/22/2024 Un/Underinsured Motorist 1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,maybe attached If more space Is required) Description of Operations:Solar Panel Installation Certificate holder is Included as an Additional Insured to the above captioned General Liability Policy for on-going&completed operations on a primary& non-contributory basis;Additional Insured to the Automobile Policy for work the insured is performing provided a written contract exists requiring such a status. Per the terms of the policy,coverage for an additional insured is contingent upon an underlying written contract with the named insured requiring such coverage. There Is a Waiver of Subrogation Included In the General Liability,Business Auto.30 day notice of cancellation except 10 for non payment of premium. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Route 25 PO Box 1179 AUTHORIZED REPRESENTATIVE Southold NY 11971 V���Vf1�T/if>RfifL li><�.G @ 1988.2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks.ofACORD venture sot r 0 10/27/2023 Alexandra Wagner 640 Chestnut Rd Southold, New York 11971 Re:Solar Panel Installation Dear Mr./Ms.Wagner, At your request, Patrick Bussett of Venture Solar LLC(NY license#105278), has carefully reviewed the existing roof framing and the proposed connection of the panels to the roof for the building referenced above. The following building codes were used in conjunction with the 2020 Residential Code of New York State to generate pertinent design criteria: ASCE 7-16—Minimum Design Loads for Buildings and Other Structures International Residential Code 2018 Edition(IRC) National Design Specification for Wood Construction 2018 Edition (NDS) Design Criteria: Design Gravity Load: Snow/Live Load=25 Ibs/ft2,Dead Load=12 psf Design Wind Load: V„ii=127 mph; Exposure B, Risk Category II *Wind loads exceed seismic loads and therefore govern the design Field observations identified the following conditions: The new solar panels will impose an additional dead load of approximately 3 psf.The roof consists of asphalt shingles over plywood sheathing supported by 2x10 rafters at 16"o.c.The rafters are sloped at a 27°pitch and have a maximum projected horizontal span of 16'-6"±.The framing is assumed to be Douglas Fir#2 graded or better. The calculations determined that the existing framing has adequate capacity to support the PV panels as shown in our PV panel layout plan with no structural upgrades required.1 therefore certify that this installation complies with the applicable codes and is acceptable for approval. Please feel free to contact me if you have any questions or concerns. ��OFNEWy Best, n 105278 Patrick Bussett, PE �FESSION`P� Email:patrick.bussett@venturesolar.com venture solar SOLAR ELECTRIC GENERATION INSTALLATION ON EXISTING RESIDENCE: 1�a ='( r°�= 640 Chestnut Rd, Southold NY 11971-2468, USA v cacolzmatsa SCOPE OF WORK 640 Chestnut Rd,Southold,NY SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR 11971-2468,USA ELECTRONIC GENERATING SYSTEM.ALL OTHER WORK IS NOT TO BE Tin S Thant]cost Douma s Residence SITE PLAN RELIED UPON AS BEING APPROVED AND/OR PERMITTED BY THE Solar az ane s: rumwu Q-CellScale:1/16"=l'-0" BUILDINGS DEPARTMENT. Moil" Inverters:(19)IQ8PLUS-72-2-US MitAnverters NOTES Solar System DC Size:7.70KW AC Size:5.51 KW The existing roof structure for this project,as is or with the structural Solar Annual Production:6,150.00 KWH / / reinforcement specified on page S-000.00,has been structurally Designed By.UNIRAC / analyzed and has been determined to be capable of supporting the Date:l0/26/2023 loads imposed by the installation of the proposed solar electrical generating system as described in these design documents. Revision# Approval Date Description 77tere is no tree,utility fine or any other potential hazard that could come into contact with any part of the solar electric generating system. APPLICABLE CODES AERIAL SITE VIEW , ' ELECTRICAL All proposed work shall meet the standards specified in the 2020 Residential Code of New York,2017 National electrical ' ' code and all other applicable local and state building and fire �tib Existing Driveway INSPECTION REOUIREC codes. TT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE HDUCATTON LAW,FOR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY ITEM SPECIFIED OR OTHERWISE INCLUDED ON TH3S DESIGN DRAWING IN ANY WAY. ' �-• �J' �� \ THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT ,. . N, �(� \ SUPERVISION OF PATRICK BUSSEIT,P.E.NY PROFESSIONAL ENGINEER LICENSE #105278,ACTING AS AN INDWIDUAI.�SOLE PROFESSIONAL ENGINEER ROOF ER OF LAYERS: SHINGLE01 ., Existing Utility Meter Location: Outside NUMBERGFLAYERs:-ol Existing Main Service Panel Location: Inside Basement Proposed location AC Disconnect: Outside ei /p Proposed location Combiner box: Outside MAP OF BLOCK`DISTRICTS • , .r. APP 0 EO AS NOTED CONNECTICUT i Q� � J ' pA By.j -12nn hh RHO[ New Haven < iSLA6 / ' t�r 13 a N�Brigepot 1.7`r rS Y: ILDING DEP ARTMENT AT '�siatt 63 � o�5-*2 8AM TO 4PM FOR THE 67 West St,Brooklyn,NY 11222 ' J Sot didd,NY 11971, �.�j INSPECTIONS: License 1os27g -_ Lw J � ,.1. f`�UI'DATION-TWO RE ew York Uh*w states U,_ CIUIREDFOR POURED CONCRETE 1p�rvt BusUGH-FRAMING&PLUiV�81PJG Id INSULATION pp, 4 FINAL-CONSTRUCTION MUST GPS COORDINATES o �G ,ra`t`; BE COMPLETE FOR C.O. Fo 105s78 41.069881,-72.448082 /�O x' A�'�FE$$10�P� c�ONSTRUCTION SHALL MEET THE � ✓ice c�0. �, DRAWING INDEX �J�� 01REMENTS OF THE CODES OF NEW P.EJR.A.Stamps/Signatures 1 Zoninglnfotmadon,Site Plan Z-".00 t7��r,.� t/ \`.`� ��� �'/ - �f(C1HK STATE. NOT RESPONSIBLE FOR 2 Elevations ands stem Layout A-000.00 Roof Access Point t �'�,Li, v y y V _V JcjJ �. ` �, vn, C� DESIGN OR CONSTRUCTON ERRORS 3 Site Plan Z-001.00 4 Racking and Load Calculations S-M.00 ~�, ��Q (Avg ��y�J 10 023 5 Spreadsheet S-MI.00 .so\ DOB Stamps/Si tares G-000.00 Proposed Micro-Inverters Integrated COMPLY WITH ALL CODES OF 6 Labels&Solar Map Placard �. % �,�; NEW YORK STATE&TOWN CODES 7 String Diagram E-000.00 \ �i Solar Panel Installations `� ,k��Y�,. �� . ,,�. g Label Sbeet E-001.00 'J '•' '• AS REQUIRED AND CONDITIONS OF 9 Electrical 3-Lint&Labels E-002.00 Existing Chimney "`U MOO 'n N ZBA 10 BOM G-001.00 1. ch/ , �'`1� ---- WV 11 IOLU T �' L SOUTHOLD OWN PLANNING BOARD LEGEND ' �� RTIFICATE Existing Tree (Typ. � t ��' .;�� -SOUTHO TOWN TRUSTEES ® Proposed Panel - Property Line �'�C PANCY ---N.Y.S. C ZONING INFORMATION, Existing Building O F -..1 v - OLD HPC rSSITE PLAN _ D r1� 000.00 Fire SetbacWAceess Path --��� Scale:1/16"=l'-0" o O Obstruction N Page 1 of 10 IT IS A VIOLATION OF ARTICLE 145, CTION NEW YORK STATE 209(2) SYSTEM LAYOUT EDUCATION LAW,FOR ANY PERSON,UNLE S7HE OR SHE ISACTING UNDER TIM ELEVATION LEGEND venture solar s,ac 3/32"=r-0' DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY ITEM SPED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT c--z Vent Pipes 67wmc S%Brwdyn.NY IL2 2 SUPERVISION OF PATRICK BUSSETT,P.E.NY PROFESSIONAL ENGINEER LICENSE U 44",16",12"Tall rm mbw ]'cm #105278,ACTING AS AN INDWIDUALISOLE PROFESSIONAL ENGINEER �-(a00)2034159 • ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO 640 Chestnut Rd,Southold,NY NOT REQUIRE THE PLACEMENT OF OF GROUND LADDERS OVER ElVent Box 11971-2468,USA Existing Utility Meter Location: Outside OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT Tin S Thant Ioost Douma's Residence r STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS O Vent Fan .at apes: anw a Existing Attic Vent Existing Main Service Panel Location: Inside Basement WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LD4BS,WIRES OR SIGNS. Invencts:(19)IQ8PLUS-72-2-US Mim-Inverters Proposed location AC Disconnect: Outside Skylight Solar Systcm DC Size:7.70KW AC Size:5SIKW Solaz Annual Production:6,150.00KWH Proposed location Combiner box: Outside Designed By:UNULAC PJ Date:10/26=3 �C2 Revision# Approval Date Description `Q \ `\ Proposed Micro-Inverters Integrated Solar Panel Installations w P� Existing Chimney F Pa 0o Roof Access Point LQ��OoS ,yb 4�' a Existing PVC Pipe (Typ. N Proposed Solar Panel Array Patrick Bussett vennne Solar 67 West St,Btooldyn,NY 11222 Mieroinverters integrated with the panels License#105278 Smoke ventilation Smoke ventilation Proposed Solar Panel Arra IQ��OK ou'r, p p y Proposed Solar Panel Array On *h4�� Sf,� Microinverters integrated with the panels Other Side Of Roof 105278 a c Mi. F�A��FESSIONP�`` ' P.EJR.A.Stamps/Sigoatmes m Existing Utility Meter Socket m % (New Net Meter) o 0 0 0 0 o Q� w10/ 26a023 DOB sn a/s atureurea DODO 5,�„ o00 000 000 000 Solar Electrical Installation—] Enphase combiner panel with PV monitoring 1. Enphase AC Combiner Panel (Located Adjacent To Utility Meter) Existing Utility Meter 2. PV AC Disconnect PV AC Disconnect Socket (Located Adjacent To Utility Meter) (Located Adjacent To Utility Meter) (New Net Meter) ELEVATIONS,SYSTEM LAYOUT O ELEVATION SOUTH EAST ELEVATION NORTHEAST A-000.00 O I (RIGHT SIDE OF HOME) Scale:3/32"=F (BACK SIDE OF HOME) Page of 10 LEGEND SITE PLAN IT IS A VIOLATION OF ARTICLE 145,SEC-ION 7209(2)OF THE NEW YORK STATE venture solar- EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SEE IS RECORCTINGD, UNDER THE j p��pal Stxlc3/16"=1'-0" DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,1'O ALTER ANY ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT EJ Existing Building 67 Wat Si,Broomya.NY Ilm SUPERVISION OF PATRICK BUSSETT,P.E.NY PROFESSIONAL ENGINEER LICENSE wwr,.vmnvchomaolrsaa (800)203l159 J�Q #105278,ACTING AS AN II4DIVQ)UAlISOLE PROFESSIONAL ENGINEER ffiaWAcc 640 Chestnut Rd,Southold,NY O tty, Fire� �Path 11971-2468,USA C��Pi 3' Obstruction Tin S Thant Ioost Douma's Residence 0 ,� — a 3' Existing Utility Meter Location: Outside -2-USMicro-Inverters , Existing Main Service Panel Location: Inside Basement Inverters:(19)IQ5ffi2 Solar System DC Size:7.70KW AC Sizc:"1 KW CCF BSA, / Proposed location AC Disconnect: Outside Solar Annual Production:6,150.00KWH Designed By:UNIRAC ,_,. , ; Proposed location Combiner box: Outside Date:10P6/2023 '9 Revision# Approval Date Description oJCo Existing Chimney o 1 o m O A. 4 Iv b� �t Q` r� Patrick Bussett Venture Solar 3' 67 West St,Brooklyn,NY 11222 License#105278 GQ 3' q"0, EOF NEW BUSS I�p�t Co P4 3 W 3' Proposed Micro-Inverters Integrated Solar Panel Installations `'�, 105278 _ FES$�ONP� 07 O P.EJRA-Stamps/Signatures Roof Access Point 10 6/2023 DOB Stamps S' anus SITE PLAN Z-001.00 Scale:3/16"=l'-0" N Page 3 of 10 LEGEND venture solar UNIRAC STAGGERED STRONGHOLD ROOF ATTACHMENT Hanwha Q-C.11Q.PEAK DUOB DUO BLK M[.GIO+40J Sdc PaRrL 67 WMSt.amn674 NY 11222 .,ta .—hl, Scale:3/16"=1'-0" RAILS 1eao1 203a138 640 Chestnut Rd,Southold,NY Roof A ATTACHMENTS11971-2468,USA ____ P-k=RS I S Thant Joost Douma's Residence Pawls:SoLar a 92'-10" Invert.(19)IQBPLUS-72-2-US Micro-IoverteTs 1 I , 1 I 1 I I 1 I , 1 I 1 1 1 I I 1 1 1 I i 1 I I 1 /11 I I I I 1 1 1'-8" Acceptable Rail Mountie Area Soles System DC Size:7.70KW AC Sizes:5.51RW 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 P gIilr'111" I II I I I I I I 1 I I I L-Feet Rail Supports shall be installed at each Sol.Anneal Production:6,130.00 KWH 1 1 1 1 1 1 , 1 11 , 1 , I I I6'-3" end Of rail and every 48"there after t0 support Designed By:UNIRAC 11111111 1 1 1 1 1 I I II II II I IIDatc:lOR6Ro23 I I I I I I 1 1 1 1 1 all Solar array wind and snow loads.Roof 1 1 1attachments shall be staggered. Revision i App-val Daft De�P� 1 II I I I1 1 1' 1 1 11 1 1IT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE I I I I I I I I I I I I 1 I I I I I I 1 , EDUCATION LAW,FOR ANY PERSON,UNLESS 13E OR SHE IS ACTING UNDER THE 1 1 1DIRECTION OF TI�LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY I I IITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. I I 1 1 1 I I I I 1 1 1 1 1 I I I I I I I THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT ( I I I I I I I I I I I I I I I I I I I I SUPERVISION OF PATRICK BUSSEIT,P.E.NY PROFESSIONAL ENGINEER LICENSE I I I I I I I I I 1 1 4 1 N 105278,ACTING AS AN INDIVIDUAIAOLE PROFESSIONAL ENGINEER NUMBER OF MODULES-19 MODULES 31'-10" 37'-5" 13'-6" 9'-8" 5" MODULE TYPE=Hanwha Q-Ce6 QYEAK DUO BLK MIA10+405(405W)MODULES MODULE WEIGHT-48.5 LBS 122.00 KO. MODULE DIMENSIONS=74.0"X 41.1"=21.12 SF UNIT WEIGHT OF ARRAY=2.30 PSF Roof B Unirac Stronghold Attachments @48" O.C. 35' u i i1 I I I I I I I I 2 X10 Rafters @ 16 O.C. 1 1 1 1 1 1 1 1T I I -4" I I 1 1 I I I I I I I 17'-1" 11 1 I I I I 1 1 1 1 1 1 1 ( I I I I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 , 1 1 1 1 1 1 1 1 1 1 1 1 1 1j1111111111111 6' I I I I I I I I I I 1 1 1 1 I I I I I I I I 1 1 1 1 1 7-1" 18'-8" 9'-3" Patrick Busses Venture Sol. 67 West St,Brooklyn,NY 11222 License 1110527E OF NEW, # ROOF STRUCTURAL DETAILS: RAIL LOC:TIO" Scale:1/8"=1 :RR:T RERI.IER wc:TI4% R 1ritR.JCiTy" V L LOC:T ON ROOF TILT:260&270 �~ `�'� 10�-5�.278 CJS��r� ROvr"E"tTR:T'vN= 2"X10" Rafters @ 16" O.C. P.E./R.A.StanWSignatures Ridge Beam Ridge Beam < f \ Unirac Stronghold Installation Unirac Stronghold Installation 1Qawzo23 DOB S S' atnres 2"X 10" Rafters @ 16" O.C. � � Y L-Collar Tie ollar Tie Roof B RACKING AND LOAD Roof A CALCULATIONS The PV modules will be maximum 6"off the roof surface. S-000R� Scale:SEE scALfi Page 4 of 10 �T UMOUNT RAIL. STRONGHOLD INSTALLATION NXT UMOUNT RAILS MAX:SPAN venture solar Scale:1/16'=1-0" Scale:1/16"=1-0" Scale:1/16"=1-0" Maximum Continuous Spliced Rail Length for NXT UMOUNT e7w.ae ,eu.lr�zxlANNIRA Rail with Stronghold Attachments(ft.)/Maximum Reaction ro�lml�158 HXT t PART.TABLE 640 Chestnut Rd,Southold,NY P/N DESCRIPTION Force(lbs) 11971-246$,USA y SHCPKTM1 STRONGHOLD ATT KIT COMP MILL nt Spacing Tm S 71"Joust Douma's Residwa DISCOVERY©i NX .I1M©lH\i mra I 1 SHCPKTD1 STRONCiIOLDATTKITCOMPORK AttaChme Solars: _ - SHG4(TMI-NS STRONGHOLD ATT COW K 1(NS) AT a 24' 48' 72" .: ?he culmmucr,of&M bw dnades c1twien - SHCPKTDl-NS STRONGHOLD ATT COMP CRK(NS)r�....►�. sr+:rvr i ' ' Inv.:(19)IQSPLUS.72-2-US14Tcro-lnvetten Tiaigivlaidt;4gi�ri uei;ere.Eridg.arsl8 :-� � = ]� ' a'�` : � t" 40 67/155 44/218 117/272 S pOctt ad a rdwP4 v eph c�n a sNe few^; Solar System ze:DC Si 7.70KW AC Size:5.5IKw 50 59/171 86/250 105/305 vfiztm�s tt cup hdeMth2141T 1)IaQ NT Soler Annual Production:6,150.00 KWH 'OsOdUMA%APLVTY am.AU1 -"..moo•-•�- """'�- - -_ 60 55/191 78/272 93/324 Designed By:UNEtAC ' Date:1026Iz023 'fe■,rEl wale """""' '. _ 70 51/207 70/285 81/329 80 47/218 62/288 80/372 Revision# Approval Due Description - ,N�A 90 43/225 62/324 69/361 100 1 43/250 54/314 64/372 120 39/272 53/369 53/369 140 35/285 45/366 45/366 TT IS A VIOLATION OF ARTICLE 145,SECTION - - -_:ci Nrreasz.+iu - Nlsae E r - 7209(2)OF THE NEW YORK STATE EDUCATION - _ - _ - StSiRAT®RAt4GE HIX SCREW aaE-ef�� a�M LAW,FOR ANY PEELS ON,UNLESS HE OR SHEDS '�. -, - Maximum Continuous Spliced Rail Length for NXT UMOUNT ACTING UNDER THE]DIRECTION OF THE LICENSED Rail with FLashkit Pro Attachments(ft.)/Maximum Reaction PROFESSIONAL ENGINEER OF RECORD,TO ALTER 4 Fore in ANY ITEM SPECIFIED OR OTHERWISE INCLUDED - -... - - -:: .. ONTIM DESIGN DRAWING IN ANY WAY. �����' � - � HETcnrAt)abTlIENT setH.tiv t -. THESE DESIGN DRAWINGS HAVE BEEN5 1 ,.:...:,..,. �..k.'...w.:.a.... Q...,.aW Attachment S acin z � PREPARED UNDER THE DIRECT y.,rvc E azw+ew;>,Crr. SUPERVISION OF PATRICK BUSS P.E.P. NY PROFESSIONAL ENGINEER LICENSE# 1" ..- 5/16•.4SSLAG1KXT AT = 24" 48" 72" :i 105z7S,ACTING AS AN INDLVIDUAIJSOLE - he^ _ ""` """-+""' "" = w/ss tBroM tHormtD WASHER 75/13 PROFESSIONAL ENGINEER _: �,-•= SIG 40 9 102/189 129/239 - SO 67/155 94/218 117/271 60 63/175 86/239 105/292 70 55 178 78/253 93/302 ::'U N I RAC PROOl1CT LINE' N�uMa1Nr DRAWING NOT TO SCALE 80 51/189 70/259 93/345 DRAWING TYPE: PARTS ASSEMBLY ALL DN ARE 90 51/213 70/308 1 81/338 NOMINAL Q 1411 BROADWAY BLVD.NE R N •ll9UQJERpuE.W 37102 LEA DESCRIPTION: PRODUCT PROTELTID m' z 100 47/218 62/287 80/371 Ph0NE:505.242bt11 M ONE OR MORE US PATE M 120 43/239 62/345 66/367 WIAAWRX00M REVISION DATE: 11/172022 LEGAL NOTICE SHEET 140 1 39/253 54/350 57/370 INVERTER IQ8 PLUS SPEC-SHEET COMBINER BOX 4 SPEC-SHEET seek,1/16".1-0" Scale:l/16"=I-0" PV MODULE SPEC-SHEET I08 and 108-Microinverters IQ Combiner 4/4C Format 74.0 in x 41.1 in x 1.26 in (including frame) MoOE�M Patrick BusaEn (1879 mm x 1045 mm x 32 mm) venture Solar ,,.ao =u... ,e.."." .,Kw..�.. ..wb..m• A. �m-a.-<" 67 Wag St,Brooklm NY 11222 Yw./W,W-L.Du,/W M.,fb4e@N•- v..wH:M::9,N Fo,etr License#1D5278 Weight 48.5 lbs(22.0 kg) -.,"....,.m«. a/« =/s eceEasoa,eE4aoEo�4cE«ENr>..ra u,n,�„e.n,aa.....mwn•� P.��,OF NfW Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with 10K su anti-reflection technology Back Cover Composite film 105278 c� Frame Black anodized aluminum "W B, —'----- Cell 6 x 22 monocrystalline Q.ANTU M solar halfcells -- P.EJAA.Stampe/Signatures Junction Box 2.09-3.98 in x 1.26-2.36 in x 0.59-0.71 in (53-101mm x 32-60mm x 15-18mm), IP67,with bypass diodes Cable 4 mm2 Solar cable;(+)>_49.2 in(1250 mm), (—)>49.2 in(1250 mm) DOB Stamps/Si annE. Connector Staubli MC4; IP68 :v.v x"••`>••c.f•,•••• Iµ,M-REYET eaNMLET,M OIr10Ne _ mveaps„u,.o�nmK `OYKII.MCE _� .-- a+ro%+.cc SPREADSHEET E}C�+C4150b3£YLL4II�P�Al� - .•".. Sale:SEE SCALE Page 5 of 10 MODULE SPEC-SHEET CONDUCTOR SIZING CALCULATION venture solar NO.OF Isom(690.(8B)(2Ha) SPECIFIED AMPACITY @ AMBIENT CURRENT COND.OF USE APPPLIF� CIRCUIT DESCRIPTION Imax(690.(SA)) TEMPERATURE CARRYING 6 ELECTRICAL CHARACTERISTICS INVERTERS talc colrout-roR 90°C °C colro. (9o.(sBX2)(b)calc POWER CLASS 355 390 395 400 405 13 40A x 1.0(amb.temp)x 1.0 67 w�St,amttm.NY I IM -' PV SOURCE STRING 1 10.00 12.10 12.10 x 1.25=15.13 #10 THWN-2 40 26-30 (raceway filU)=40.00A IONIM UM PEPFORMANCE AT STANDA RD TEST CONDITIONS,STV(POWF.'n T7•.ERANCE.5 W/-0W IWO)2034158 Power at MPPI P_ IWI 385 390 395 400 405 640 Chestnut Rd,Southold,NY PV SOURCE STRING 2 9.00 10.89 10.89 x 1.25=13.61 #!0 TfUWN-2 40 26-30 1-3 40( x 1.0(amb. e40. x 1.0 Snort Circuit CurrenN Lc JAI 11.D4 11.07 1110 11.14 11.17 (raceway fill)=40.00A 1 197 1-2468,USA Open circuit Voltage, V M 4519 45.23 45.27 45.30 45.34 75A x I.0(amb.temp)x 1.0 Tm S Thane Ioost Douma's Residence COMBINER BOX OUTPUT 19.00 22.99 22.99 z 1.25=2fl.74 N6 THWN-2 75 26-30 1-3 (raceway fill)=75.00A Current at[a1PP I_ [A] 10.59 10.65 10.71 l0A 10.83 oar Panels: anw a 36.36 36.fi2 36.88 37.13 37.39 75A x 1.0(amb.temp)x 1.0 405 Ma"CS Voltage at MPP V„n IV] AC DISCONNECT OUTPUT 19.00 22.99 22.99 x 1.25=28.74 #6 THWN-2 75 26-30 1-3 (raceway Fill)=75.00A Inverters:(19)IQ8FLUS-72-2-US Micro-Inverters E`11--y' _z19.6 _z19.9 z20.1 z20.4 z20.6 MINIMUM PER-FOP.t4ANCE AT NORMAL OPERATING CONDITIONS,NMO'r Solar System DC Size:7.70KW AC Size:5.51KW Power at MPP P_ IWI 288.8 292.6 2963 300A 303.8 gpCKFEED CALCULATIONS NEC 705.12(D)(2) IT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE Solaz Annual Production:6,150.00 KWH Snort C'rcuM.Current ]Aj 0.90 8.92 8,95 8.97 9.00 Bulbar rating x 120%-Main Breaker=Solar Breaker SizeEDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE Designed By:UNIRAC _ on-Circuit Voltage V- IV] 42.62 42.65 42.69 42.72 42.76 200A x 120%-200A=40A DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY ` ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. Date:10262023 2 Currant at r.',PP I- [A] 8.35 8,41 846 6.51 8-57 THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT Revision# Approval Date Description yoRage at MPP V_ IV] 34.59 34.81 35,03 35.25 35.46 SUPERVISION OF PATRICK BUSSEIT,P.E.NY PROFESSIONAL ENGINEER IICENSE Meawramem Iderencea P,,,..x3%;Ix;Vcc'S%RSIC:1000W/m',25 2'C,AM1.5 eccordmg to IEC 60904-3•'BCC W/mr.NMCT,spectrum AM 1.5 STRING CALCULATIONS #105278,ACTING AS ANINDIVIDUAL/SOLE PROFESSIONAL ENGIN== (10)x 1.21A x 1.25=15.13A QOA->OK (09)x L21A x L25=I3.61A Q0A->OK SERVICE FEED SOURCE:UNDERGROUND String 1 ROOF A&B elf Bonding Panel and Rail String 1 Line 1 10 String 1 Line 2 Solar Panels - - - (19)Hansrha O-Cell O.PEAx L Strin 1 Ground DUO Buc(4w0L5W)0+ 405 String 2 ROOF_ A (2)Ll Red#10 Copper Conductors THWN-2 String 2 Line 1 2)ACPV Cables (2)L2 Black#10 Copper Conductors THWN-2 09 j [ - String 2 Line 2 ! (1)Grounding Green#6 Copper Conductors THWN-2 L Suing 2 Ground Length of Conductor:30' I Bond Conduit Length of Conduits:30' 1"EMT Aluminum Conduit i SolaDeck Bond to Equipment Junction Box ROOF TOP ctors THWN-2 SIDE OF BUILDING INSIDE BASEMENT SIDE OF BUILDING (2)L2Blackl Red 10CpperCoer ductosTHWN (2)L2 Black#10 Copper Conductors THWN-2 (1)LI Red#6 Copper Conductor THWN-2 (1)Grounding Green#6 Capper Conductors THWN-2I (1)L2 Black#6 Copper Conductor THWN-2 Length of Conductor.30' (1)Neutral#6 Copper Conductor THWN-2 Length of Conduits:30' (1)Ll#6 Copper Conductor THWN-2 (1)Grounding Green#6 Copper Conductor THWN-2 1"EMT Aluminum Cond t (1)L2#6 Copper Conductor THWN-2 Length of Conductor:5' (1)Neutral#6 Copper Conductor THWN-2 Length of Conduits:5' j (1)Grounding#6 Copper Conductor THWN-2 1"EMT Aluminum Conduit a,. Length of Conductor 10' Length of Conduits:l0' .� O 1' EMT Aluminum Conduit ---------J A/C i Existing Utility Meter Socket (New Net Meter) Existing Square D ___--_ --Not To Exceed------ -- DOB Stamps/Si attires Meter#98364758 200A 200A 10 g New Exterior 125A Account#9636103458 120/240V Main Breaker Enphase Main Panel IQ Combiner 4 (X-IQ-AMI-240-4) (1)Grounding u�wA Conductor PV Backfeed LOCKABLE&TAGGABLE New Exterior PV AC DISCONNECT 1/2"GEC ` Breaker 89L Type 3R Enclosure RB Water Main \_(1)Grounding#4 60A A/C Dis O t,Eaton e ) Conductor (l oca rd Adjacent to U it Tytyet¢) M ELECTRICAL 3-LINE& Supplemental Ground Rod LABELS GEC E-002.00 Scale:NTS Page 9 of 10 venture Solar IT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY 67 w.+Wm S•Brucm HI yo NY 11222 ITEM SPECIFIED OR OTHERWISE INCLUDED ON TIES DESIGN DRAWING IN ANY WAY. ..mm sam,da�a THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT pool 203-4158 SUPERVISION OF PATRICK BUSSETT,P.E.NY PROFESSIONAL ENGINEER LICENSE W Chestnut Rd,Southold,NY N 105278,ACTING AS AN INDIVIDUAL/SOLE PROFESSIONAL ENGINEER 11971-2468,USA Tin S Thant Ioost Douma's Residence Solar ane =. Labels comply with NEC 110.21(B) and ANSI Z535.4 III K Inverters:(19)IQ8PLUS-72-2-US Micro-Inverters Solar System DC Size:7.70KW AC Size:SS I KW Solar Annual Production:6,150.00 K WH Designed By.UNIRAC Date:1 On6=3 Revision# Approval Date Description COMBINER PANEL JUNCTION BOX AC Output Current: 22.99A COMBINER PANEL Nominal Operating AC Voltage: 240V ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS AC DISCONNECT PHOTOVOLTAIC SYSTEM ARE AC Output Current: 22.99A A/C DISCONNECT UNGROUNDED AND MAY BE Nominal Operating AC Voltage: 240V ENERGIZED COMBINER PANEL IWPMAIN DISTRIBUTION PANEL O4IN G j ACAUTION INVERTER OUTPUT CONNECTION; DO NOT RELOCATE THIS TWO POWER SOURCES INSIDE OVERCURRENT DEVICE UTILITY AND SOLAR PV JUNCTION BOX Patrick Busxtt • a Venture Solar CONDUIT EVERY 10 FT 67 West St,Brooklyn,NY 11222 SOURCELicense#105278 � ,Qf NEW y, SHUTDOWNK BUS SOLAR PV SYSTEM EQUIPPED, WITH RAPID W 105278 TURN WD SHUTDOWN RAPID SHUTDOWN SS�pNP� SWITCH TO THE'OFF' SYSTEM POSITION TO SHUT DOWN CONDUCTORS OUTSIDE P.EJR.A.StN°pc(Sigaatures THE ARRAY.CONDUCTORS WITHIN THE ARRAY 9 REMAIN ENERGIZED IN SUNLIGHT. ]0 023 DOB Stamps/Signatures 1•NOT RELOCATEI OVERCURRENT DEVICE LABEL 2.1 SOLAR PV SYSTEM EQUIPPED PHOTOVOLTAIC SYSTEM POINT OF WITH RAPID SHUTDOWN INTERCONNECT. Q A AT RAPID SHUTDOWN TURN PAMSHUTDOWN SOLAR sa SYSTEM trcH ro rHE roFF- BREAKER IS POSTM TONarr DOWN 1 w sysrat AND REDUCE SHOCK HAZARD N THE LABEL z.z ARRAY. LABELS PHOTOVOLTAIC SYSTEM POINT OF Di INTERCONNECT, lln_000.00 Scale:NTS Page 6 of 10 TION • ■ ■`U�� solar IT IS A TION LAW,OF ARTICLE SO ,UNLESS 72E O SHE IS NEW YORK STATE EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SHE[S ACTING UNDER THE . •sUa String Diagram DIRECTION SPECIFIED THE LICENSED PROFESSIONAL ENGINEER OF RECORD, I ALTER ANY rrEM 67 arm St E:ootyo.NY 1= THESE DESIGN DRAWL OR GS HAVE BEEN PREPARED UNDER THE DWISE INCLUDED ON THIS DESIGN IRECT' IN ANY WAY. ....mm,onommtrs® SUPERVISION OF PAIRICK BUSSEIT,P.E.NY PROFESSIONAL ENGINEER LICENSE 640 Chestnut Rd,Southold,NY M 105278,ACTING AS AN INDIVIDUAUSOI.E PROFESSIONAL ENGINEER 11971-2468,USA Tin S Thaw Ioost Domna's Residence oar aae : w e Inverters:(19)IQSPLUS-72-2-U8 Micro-Invetee Solar System DC Size:7.70KWAC Size:5.51KW Solar Annual Production:6,150.00 KWH Front of House Designed Br.UNIRAC Date:10/26/20D Revision N Approval Date Desorption Enphase IQ8PLUS-72-2-US Micro-Inverters String 2 i 74 � a n ROOF A 14 13 12 11 10 0 3 1 (13) HANWHA Q-CELL 16 17 18 19 2 Q.PEAK DUO BLK ❑ ML-G 10+405 (405 W) 4 AZIMUTH: 129' TILT: 26' 0 9 8 11 75 Patrick Bussett Venture Solar 67 West St,Brooklyn,NY 11222 License 4 105278 7 6 ,,toF NEW,,, tring 1 It 'Qk BUSffl�P t^ i 105278 SSIONP� ROOF B P.E./R.A_Stamps/sipstures (06) HANWHA Q-CELL Q.PEAK DUO BLK ML-G10+405 (405W) �;��:F: DOB suww siaatures, AZIMUTH: 2190 TILT: 27' String Diagram E-000.00 Scale:NTS Page 7 of 10 OF NEW venture solar Labels Sheet ITTS A VIOLATION OF ARTICLE SO SECTION 72E O SMI♦ACTT YORK STATE EDUCTION LAW,MR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT 67 ww St B.Wdy.NY 11273 � SUPERVISION OF PATRICK BUSSEIT,P.S NY PROFESSIONAL ENGINEER LICENSE (UM 2W4158 A 105278,ACTINO AS AN INDMDUA1JSOLE PROFESSIONAL ENGINEER W Chestnut Rd,Southold,NY 11971-2468,USA Tin S Thant loos[Douma's Residence 01 a Fane w Inverters:(19)IQ8FLUS-72-2-US Mao-Inverters Solar System DC Si=7.70KW AC Size:5-5 1 KW String Number Module Number Sticker 11 Solar Am"Production:C150.00KWH Designed Br:UNIRAC Date:10/2EJ= Revision a Approval Date Description 1 12 2 13 3 14 4 2 15 5 16 1 6 17 7 18 g 19 9 Patrick Russet Venture Solar 61 West St,Brooklyn,NY 11222 license!105278 10 ,, Of NEW jo *c74l�QJCK SUsf��9 11' 105278 P.EJR.A.Stamps/Signanuea 10 DOB Stain Signatures Label Sheet E-001.00 Seale:NTS Page a of 10 CTION OFT venture solar E IS I A VIOLATION OF ART ANY PE SO ,UNLESS 72O<O SHE NEW YORK STATE GDUCATION LAW,FOR ANY PERSON,LINLL•SS FIE OR SIiE IS AC11NG IINDER'niE DIRECTION OF TTiE LICENSED PROFESSIONAL ENGINEER OF RECORD,I'D ALTTiR ANY ITEM SPEC'HIIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. niwrn sc is ya,NY iir= THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE.DIRECT "(NWI'_UJ-0I$N SUPERVISION OF PATRICK BUSSETT.P.E.NY PROFESSIONAL ENGINEER LICENSE N 105278.ACTING AS AN INDMDUAL/SOLE PROMSSIONAL ENGINEER 640 Chestnut Rd,Southold,NY l 1971-2468,USA Tin S Thmn Joost Doutna's Residence -nr, atxs:, , anwh.Q-L:ell QYFAK DUO BLK VENTURE SOLAR htvenem(19)IQ8PLUS-72-2-US Micro-lnvericts Solar System DC Size:7.70KW AC Size:5.51 KW Customer Name Tin S Thant Joost Douma Solar Annual Production:6,150.00 KWH Customer Address 640 Chestnut Rd, Southold, NY 11971-2468,USA Designed By:UNIRAC Date:lor-6/2023 Team UNIRAC Revision N Approval Date Dexription ROOF ELECTRICAL Description Bar Code Description Bar Code Hanwha 405 19 Enphase IQ Combiner 4 1 Portrait Q Cable-#Conn 2 Enphase Mobile Connect 1 Landscape Q Cable-#Conn 21 Enphase IQ7 Micro 0 Q Term 3 Enphase IQ7X Micro 0 Q Seal 7 Eaton 20 A Breaker 2 Q-Conn 10M 1 [PC-4/0-#6(Taps) 0 Q-Conn 10F 1 60 A Disconnect 1 Micro Inverter T Bolt 20 60A Set of Fuses 0 Wire Restraints 3 100 AMP Disconnect 0 Ground Lug 8 100A Set of Fuses 0 Pitched ROOF 125 A Solar Load Center 0 Strong Hold Box(Qty.20) 3 Square D 100 A Main Breaker 0 Unirac Rail 18 Square D 20 A Breaker 0 Unirac Splice 12 Square D 15 A Breaker 0 Unirac Ends 33 Enphase IQ Envoy 0 Unirac Mids 23 Enphase IQ7A Micro 0 Solar Seal 8 Enphase IQ8 Micro 0 Solar Deck 3 Enphase IQ8+Micro 19 Consumption CT x 1 Sets 200 Enphase IQ8M Micro 0 Fire and Smoke detector x 1 No No Enphase IQ8H Micro 0 Battery Details Manufacturer Type Mfr.Part No.&Description Qty Enphase Energy Inc Battery IQ BATTERY-5P-1P-NA 0 Enphase Energy Inc Other IQ System Controller 3/3G 0 Enphase Energy Inc Moniter COMMS-KIT-01 Ensemble 0 FLAT ROOF CONFIRMATION Chemlink 6" E-curb Kit 0 L-Foot Box w/Nut 8r Bolt(Qty.24) 0 4"Stand Off 0 Unirac Tilt 18-30" 0 Unirac Tillt 26-44" 0 DOB Stamps/Signatures Unirac Tilit 40-72" 0 Procurement Team Signature Silver Unirac Rail 0 Silver Unirac Splice 0 Silver Unirac End 0 Sliver Unirac Mid 0 4"Lag 0 8"x8"x4"Junction Box 0 Crew Foreman Signature BOM G-001"00 Scale:NTS Page 10 of 10 powered by DUO YR �Q TOP BRAND PV eusare ' Warranty 2021 Q CELLS PP w-iP.+ameriw Yield Security a„ BREAKING THE 20%EFFICIENCY BARRIER nl/IIn11�I� Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new'Quality Controlled PV"of the independent certification institute TUV Rheinland. „ INNOVATIVE ALL-WEATHER TECHNOLOGY (?: Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE JJ Long-term yield security with Anti LID Technology,Anti PID V Technology',Hot-Spot Protect and Traceable Quality Tra.Q"". EXTREME WEATHER RATING CW High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). 2g A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year VY linear performance warranty2. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) 'See date sheet on rear for further information. THE IDEAL SOLUTION FOR: 615 Rooftop arrays residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION Format 74.0in x 41.1in x 1.26in(Including frame) (1879 mm x 1045 mm x 32 mm) Tar wA°+w 11r(wu me 16.r reeeA-) Weight 48.51bs(22.Okg) Front Cover 0.13In(3.2 mm)thermally pre-stressed glass with + wr D-4 + anti-reflection technology r �.Onu^an0°wW�°.Y-la6 moll F,�r Back Cover Composite film Frame Black anodized aluminum as u.a°.0 Cell 6 x 22 monocrystalline Q.ANTUM solar half cells p Junction Box 2.09-3.98in x 1.26-2.36 in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes �� urnleSmml Cable 4mm2 Solar cable;(+)z4g.tin(1250mm),(-)z4g.2in(1250mm) ~� E•o..war. + °•YwNq•eu IDEfY AI + Connector Staubli MC4;IP68 ]L I I i1°•N,,,•,1 o[*y�A o.arNlvN °Dr rN.6 wy IyI23T Ita^'"q ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-O W) Power at MPP' P,,,,, [W] 385 390 395 400 405 E Short Circuit Current' Isc [A] 11.04 11.07 1.1.10 11.14 11.17 E Open Circuit Voltage' Voc M 45.19 45.23 45.27 45.30 45.34 Current at MPP Iv„ [A] 10.59 10.65 10.71 10.77 10.83 f Voltage at MPP V_ M 36.36 36.62 36.88 37.13 37.39 Efficiency' 111 [%] z19.6 z19.9 2!20.1 2!20.4 2:20.6 MINIMUM PERFORMANCEAT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP P) IW] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Vx [V] 42.62 42.65 42.69 42.72 42.76 c Current at MPP Ivr, [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VM IV] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances P, t3%;Isn;Vm t5%at STC:1000 W/m',25m2'C,AM L5 according to IEC 60904-3•1800W/m2,NMOT,spectrum AM 1.5 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE -O`er At least x"^ --1'--'-r--'-'r-----r--- �...d.°e..r.....r W � }first year.Thereafter max.0.5% --- - degradation per year.At least 93.5% d of nominal power up to 10 years.At i i I I F z least 86%of nominal power up to 25 years. _____-_____ i o gAll data within measurement tderanc- es.Full warranties in accordance with e0 i the warranty terms of the O CELLS zee eoe ea em raoo o e sales organisation of your respective iRRAD1AACE Iw/m+) o u ,. ee ee country. � YEARS Typical module performance under tow irradiance conditions in ..-. a..�aeer°s.anaun.<crsaw comparison to STC conditions(25'C,1000W/m2) M TEMPERATURE COEFFICIENTS 3 Temperature Coefficient of I_ a [%/KI +0.04 Temperature Coefficient ofV� [%/K] -0.27 Temperature Coefficient of P_ y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109t5.4(43t3°C) m 0 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage V_ [V] 1000(IEC)/1000(UL) PV module classification Class II a a Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 w Max.Design Load,Push/Pull' [Ibs/ft2] 75(3600 Pa)/55(2660 Pal Permitted Module Temperature -40°Fupto+185°F e Max.Test Load,Push/Pull' [Ibs/ft2] 113(540OPa)/84(4000Pa) on Continuous Duty (-40°Cupto+85°C) 2See Installation Manual a QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION ULi�y CE-compierx, I " ® Ib ss a Quality controlled w•Tl1V RneiNend IEC 81215:2016,IEC 61730:2018, A U.S.Patent No.9,893.216(eokr cexe), Sr'� ,we Wid Horizontal 76.4 in 43.3In 48.01n 16561bs 24 24 32 QCPV Certrfkeeon ongoing. CUi1e1i,US C E packaging 1940mm 1100mm 1220mm 751kg pellets pellets modules 5 °LeV10 e)11I_IX) a Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further Information on approved Installation and use of this product. Henwhe 0 CELLS America Inc. 400 Spectrum Center Drive,Suite 1.400.Irvine,CA 92618,USA I TEL+1 949 748 59 961 EMAIL Inquiry®us.q-cells.com I WEB www.q-cells.us BETTEREFUNIRAC H 0 R I Z 0 N' ONE SOLAR / A STARTS DISCOVER YOUR NXT HORIZON" NXT HORIZON'COMBO CLAMP AR DARK CCIAMPDI 4* Mltl!CCI AMPMI YE Clicks The culmination of over two decades of experience,Thoughtful design, theta aetcables!) m(eyenwherc ng rigorous engineering,world-class support,and a reliable supply chain are the combnesaSelf-standsbothmdandeng clamp with dc , , , combines as bath mid and acid clamp. foundation of what makes us confident that NXT HORIZON'is the NXT Level Clamps30-40 rpm modules of DESIGN, SIMPLICITY, and VALUE. STRONGHOLD'RAIL CLAMP DARK SHCLMPOI 112 inch module spacing la efficiency. MILL SHCLMPMI NXT HORIZON' Adaptable rail connection to attachments Darac-quality bonding that works both as CAP KIT mid and end clamps. allows click-in feature compatibility with LNDCAPDI almost all of Doina's attachments *—.go Make the Install look clean with the end cap kit desgied to complainant the mcdu'e end clamp and rail ends. 01 LOOT HORIZON'RAL WIRE MANAGEMENT OPTONS Flashlec tectnology combined with new features:click-in rail&open slot I-Foot for DARK 168RLD1 the best Rash-less install experience. MILL 168RLM1 Strong,lightweight open channel rail with invishie,easy,unfaikng STRONGHOLD'ATTACHMENT KIT and integrated wire management system DARK:SI IC?KTDI MILL-SHCPKTMI Rail clicks into the clamps attached to the NXT HORIZON'RAIL SPLICE Stronghold base.Open slot inL-foot allow s drop-in rail clamp. RLSPLCMI NXT HORIZON'MLPF&LUG CLAMP NXT HORIZON'WIRE MANAGEMENT CLIP NXT HORIZON'NORTH/SOUTH WIRE MANAGEMENT CLIP LUGMLPEI WRMCIPDI Alternative attachment options. Structural irlarnal sphce that does WRMCNSDI not interterr with root connection Works as either MLPE Mount or Grounding Aesthetic,yet functional accessory that works to or module;annecfar, Lug connection to the rail.Why source Iwo help Installers keep wires inside the rall. An elegant solution to help installers get to the sauxaua " GASXIOe0AO Fusrnc•ouo Pre-assembled thread culling bolts. parts when one can do the nob? No tip-Vas refined,Optional tip he loop for extra tome run.The same hardware wales to provide uu�»r: neA-eaosso oaAK ooaaso wire management capabilities! both easy entry to rail and adjustability forrcable MneoeaossM MLcoocn5M thickness. ALL NXT I ' 1 1 DESIGN FOR QUESTIONS OR CUSTOMERI 1 ' 1 ENPHASE. T IQ8 and IQ8+ Microinverters Easy to install Our newest I08 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability • Produce power even when the • grid is down' • More than one million cumulative hours of testing • Class 11 double-insulated Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability enclosure Microinverters integrate with the En phase IQ Battery, standards with more than one million cumulative Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- and analysis software. leading limited warranty of up to 25 years. powered PV modules Microgrid-forming • Complies with the latest advanced grid support— Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily to I08 Series 108 Series Mlcroinverters are UL Listed as Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when Installed according to range of grid profiles manufacturer's Instructions. Meets CA Rule 21(UL 1741-SA) requirements C 2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other •Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meats UL 1741. `•108 and IQBPIus supports split phase,240V IOBSP-DS-0002-01-EN-US-2022-03-17 Installations only. IQ8 and IQ8+ Microinverters Commonly used module pairings' W 235-350 235-440 Module compatibility 60-ceIV120 half-cell 60-ceIV120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current'[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA(ACI ,• .i Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-U voltage/range' V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency H: 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current MA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -400C to-600C(-40°F to+1400F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor r CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAWCSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when Installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at h"ps://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 108SP-DS-0002-01-EN-US-2022-03-17