Loading...
HomeMy WebLinkAbout49369-Z r V zxz �OSUFF�I'�cpG Town of Southold 12/7/2023 a P.O.Box 1179 o _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44805 Date: 12/7/2023 THIS CERTIFIES that the building HVAC Location of Property: 367 Riley Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 143.4-20 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/10/2023 pursuant to which Building Permit No. 49369 dated 6/13/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"HVAC as applied for. The certificate is issued to Alvarez,Philip&Ors of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49369 6/28/2023 PLUMBERS CERTIFICATION DATED A o ized i ature TOWN OF SOUTHOLD suFen�k�oG� BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • � �`+{ SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 49369 Date: 6/13/2023 Permission is hereby granted to: Alvarez, Philip 19 Orchid Ln Commack, NY 11725 To: legalize "as built" HVAC as applied for. At premises located at: 367 Riley Ave, Mattituck SCTM #473889 Sec/Block/Lot# 143.-4-20 Pursuant to application dated 6/10/2023 and approved by the Building Inspector. To expire on 12112/2024. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 1 CO-ALTERATION TO DWELLING $50.00 Total: $450.00 Building Inspector pF SO(/j�Ql 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(aD-town.southold.ny.us Southold,NY 11971-0959 CDM'�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Philip Alvarez Address: 367 Riley Ave city,Mattituck st: NY zip: 11952 Building Permit#: 49369 section: 143 Block: 4 Lot: 20 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 1 Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect 1 Switches 3 4'LED Exit Fixtures Sump Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " HVAC Inspector Signature: Date: June 28, 2023 S.Devlin-Cert Electrical Compliance Form !j " i o��oFso�yo6 q '3 b7 1�) rQ Ave# TOWN OF SOUTHOLD BUILDING/DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) !":''ELECTRICAL (FINAL) [ ] CODE VIOLATION [' l] V PREC/O [ ] RENTAL REMARKS: DATE INSPECTOR �F SOUlyolo * # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL "ff-/ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: k d DATE INSPECTOR I FIELD INSPECTION REPORT DATE COMMENTS • b r� FOUNDATION (1ST) -------------------------------------- FOUNDATION (2ND) z o �y. ROUGH FRAMING& PLUMBING r INSULATION PER N. Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS c b 39 W 113 a3 8 P C-, 4- � lwJ�• �� oss� �✓ • N Z O x -- d b 4�QgUFfOi/� ,, TOWN OF SOUTHOLD—BUILDING DEPARTMENT ' x , Town Hall Annex 54375 Main Road P.O.Box 1179 Southold,NY 11971-0959 Teleplione(631)765-1802 Fax(631)765-9502 hgps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only �G q [ID,1 PERMNO. ��• q Buildin Ins ector. P ��i� :. .: . : ..:... .:. 8000001EPT APPlications and forms.must befitted.out.in.their.entirety.ancomplete,;..: applications will'not bec�epted. 'Wl�er the Ap�licarit.is not the owner,an1�F80 .... Owners AuthorEzatiop form sha11 be�campleted,:; Date:05/08/23 P"ER(S)OF.PROPERTY:. Name:Philip Alvarez SUN!#1000-141-4 -20 Project Address:367 Riley Avenue, Mattituck, N.Y. 11952 Phone#:(631)796-6545 Email:PhilAlvarezl 3@Gmail.com Mailing Address:950 Pond Road, Bohemia, N.Y. 11716 :;CONY CT ERSO . Name: Phil Alvarez Mailing Address: 950 Pond Road, Boehemia, N.Y. 11716 Phone#:(631)796-6545 Finail:PhilAlvarez13@gmail.com .flESIGAI PttOFfcSSEONAL INFORMATION: :.. :::.. ::.,.:.. :......:. . :..:: :.::;.:::.::': :.:: .:; ::..;.:•`.:.::• ::. Name: Mailing Address: Phone#: Email: :CONTACTOR INFORMA710N: : Name:Kolb Mechanical Corporation MailingAddress:PO BOX 106 Phone#:(631)298-5527 Email: D CRIPTIONOF.PROItOSE: CONSTRUCTION.':: :`:`. .:: :`..... ;`: :`:: :` ... ES.. .. ... .... ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: EOther Existing HVAc $ Will the lot be re-graded? ❑Yes®No Will excess fill be removed from premises? ❑Yes RNo 1 `PROPER N TIO TYI FO.. .... .. RNIA M Existing'use of property:One Family Dwelling intended use of property:One Family Dwelling Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Mat l UCk this property? ❑Yes'I@No,IF YES,PROVIDE A COPY. 1c6c. gx3tari:Reding;..life owner/co!!trtctar/design.pmtessFonat is responsible tnr all drainage and storm aauater.Issues as providgd:by:;•;.:.''`; Chapter 236 of the Town lode.APPIJCATION.IS IfEREBY:MAOE to the Build Depa:<meat for.the jssuapce of a hpilding Permit pursuant to the Building Zope :Ordlnante of the Town aiSouthotd,Suttnik,Wurlt�,.NewYcrls and other appiTca6te tawg,O�dtnaitirs or.Reg�slatlat4s,•for;he wnstruetlon of 6ulWiiigsy. additions'atteratton;or:for remmral ::a brdemolitions,<te[ein:descrlbed.fibs,a h0rrt . .. .....!... .; :• ...:... .. .•. ;.:.:.:: .:.:,:.. ..:..:,.,.••...: �:.. .,......:........:.:...::.....:. .,..ep ,: a8reesto.cafpplywtth.allappGca6lelaxrs;:ordinances;biildgig�ade;.';:°;:.�: ::housing code and regulations aad:to admit authoraed inspectors on.premfses and in luilding(s)for necessary,. ns pe�tio False statements made herein are ..:. ::a c:. ... ............. . . ..:.. :. . ins ... . ...... ,... punishable as lass A misdem eanor pursuant to Secdon 210AS of the New York State.pena)law: AppiicationSubmitted ' t name):Philip Alvarez ❑Authorized Agent BOwner Signature of ApplFca Date:05/08/2023 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Th A f 17 � being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the L X—)Lc (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make-and file this application;that,ail statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of Notary Public U IluuN�� �pTAfly•.• j-y PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) ;a'No.O1VE6132423 :�s QUALIFI,ED AN SUFFOLK COUNTY;, 1; residing at s:; do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owners Signature Date Print Owners Name 2 4 BUILDING DEPARTMENT-Electrical Inspector CZ TOWN OF SOUTHOLD ` Town Hall Annex-54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov sea nd aC7.southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Name: License No.: email: Address: Phone No.: JOB SITE INFORMATION (All Infornmaton Required) Name: A U i 99L Address: (7 R 1 UY AUK. � n cK Cross Street: (J� Phone No_: 631 Bldg.Permit#: aq�� email: L M Ems( J1t L. Tax Map District: 1000 Section: 14,9 Block: Lot: �D BRIEF DESCRIPTION OF WORK (Please Print Clearly) 6sli•NC N.1( :C., FL,EC i L IDt�I Circle All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate?: YES/ NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service-Fire Reconnect-Flood Reconnect-Service Reconnected- Underground-Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Form.xis �1SG� � � T` ' � � I f � �� I NEW Department of Taxation and Finance i New York State and Local Sales and Use Tax S 1 T-1 24 STATE Certificate of Capital Improvement `12/15) After this certificate is completed and signed by both the customer and the contractor performing the capital improvement, it must be kept by the contractor.Copies of this certificate must be furnished to all subcontractors on the job and retained as part of their records. Read this form completely before making any entries. This certificate may not be used to purchase building materials exempt from tax. Name of contractor(print or type) - Name of customer{print or type) Kolb Mechanical Corporation Philip Alvarez Address(number and street) Address(number and sheel) PO Box 106 367 Riley Avenue city State ZIP code city State ZiP code Mattituck NY 11952 Mattituck NY 11952 Sales tax Certificate of Authority number(if any) To be completed by the customer Describe capital improvement to be performed: Remove and discard the existing indoor air handling unit serving the Master Bedroom which contains a failed evaporator coil.Provide and install a new indoor air handling unit. Project name 367 Riley Avenue Street address(where the work is to be performed) city State ZIP code 367 Riley Avenue Mattituck NY 11962 1 certify that: • lam the(mark an X in one) 91 owner ❑ tenant of the real property identified on this form;and • the work described above will result in a capital improvement to the real property as outlined in the instructions of this form;and • this contract(mark an Xin one) ❑ includes Q does not include the sale of any items that will not become a permanent part of the real property(for example,a free-standing microwave or washing machine). I understand that: • I will be responsible for any sales tax,interest,and penalty due on the contractor's total charge for tangible personal property and for labor if it is determined that this work does not qualify as a capital improvement;and • f will be required to pay the contractor the appropriate sates tax on tangible personal property(and any associated services)when the property installed by the contractor does not become a permanent part of the real property;and • I wlylbef ubject to civil or criminal penalties(or both)under the Tax Law if I issue a false or fraudulent certificate. SI ature _custoftp Title Date y�- Homeowner or General Contractor �101-13-2023 To a comp ed by the contractor I,the contractor,certify that I have entered into a contract to perform the work described by the customer named above,and that I accept this form in good faith.(A copy of the written contract,if any,is attached.)I understand that my failure to collect tax as a result of accepting an improperly completed certificate will make me personally liable for the tax otherwise due,plus penalties and interest. Signat ontra;tor or officer, Title IDate Sub-contractor Representative 101413-2023 This certificate is not valid unless all entries are completed. Philip Alvarez 367 Riley Avenue Mattituck, N.Y. 11952ryJ HIT to I,l 1:....._..._ 1, r Air Conditioner Condenser l fA+:llit. lljJ Id +11 4., I,hRArf' 4�3, 1 MIVAII IWAI-WAY I' O LOT 7 1 h, " 1 vt ii. mill M; ta. V r ( 1 -} �1 ��VE 367 Riley Avenue Mattituck,NY 11952 DEC — 6 2023 �m Measurements: BuiEdirsr r=�a?�..e.�,•e»t Doors F ox;•.,n of - . :'s 1) West side-Front: H 78.25"X W 35.75" 2) South side-Back: H 79.25"X W 31.75" Windows: 1) South side: H 45.5"X W 40.5" 2) South side: H 45.5"X W 40.5" 3) South side: H 45.5"X W 40.5" 4) South side: H 45.5"X W 40.5" 5) South side: H 45.5"X W 24.5" 6) East side: H 45.5"X W 28.5" 7) East side: H 57.5"X W 28.5" 8) East side: H 57.5"X W 28.5" 9) North side:-H 33.5"X W 26.75" 10) North side: H 49.75"X W 28.5" 11) West side: H 45.5"X W 24.5" 12) West side: H 45.5"X W 24.5" 13) West side: H 45.5"X W 26.5" 14) West side: H 45.5"X W 26.5" r I Al ROVED AS NOTED DATE: 3 B.P.# 3�p FEE: . 6D BY:­JLL NOTIFY--BUILDING DEPARTMENT__AT . 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS". . ` 1. FOUNDATION.... TWO REQUIRED FOR POURED CONCRETE. 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL,-, CONSTRUCTION.MUST BE COMPLETE FOR C.O. ALL;CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND,CONDITIONS OF G BOARD SOUTH RUSTEES N.Y..=LDK- OCCUPANCY OR USE IS.UNLAWFUL WITHOUT�CERTIFICAT OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED Page No: 1 of 2 Pages 11500 Old Sound Avenue,PO Box 106 • O Mattituck,New York 11952 P 631-298-5527 1 F 631-298-5534 HEATING + C O,O L I N G www.kolbrnechanical.com PROPOSAL SUBMITTED TO [367 HONE DATE STREET SAAME 367 Riley A Rile Avenue CITY,STATE AND ZIP B LOCATIONMattituck NY 11952 Mattiuck NY 11952 EMAILADDRESS ELL PHONE Fin 6 ma aircons ruc ion.com ]z/gs' We hereby submit specifications and estimates for. Remove and discard the existing indoor air handling unit serving the Master Bedroom which contains a failed evaporator coil. Provide and install a new indoor air handling unit which .utilizes R-410A Puron non-ozone depleting environmentally compliant refrigerant to consist of the following: Scope-of-Work: • Pump down and reclaim refrigerant from the existing condensing unit refrigeration circuit as per EPA regulation Title 40 CFR, Part 82 and Clean Air Act, Sections 601- 607. • Remove and dispose of the existing indoor air handler. • Provide and install one (1) Rheem Classic Series 2-ton, 208/240V, air handler to be installed at the existing air handler location in the residence attic, suspended from roof rafters by means of threaded rod and kindorf with a secondary drain pan and moisture sensor. • All refrigeration piping connections to be silver brazed. • Flush refrigeration lines. • Evacuate refrigerant circuit to 500 microns deep vacuum. • Provide connections for power wiring and control wiring to accommodate new unit configurations. • Provide necessary duct modifications and new duct transitions to accommodate the installation of the new air handler. • Charge refrigerant circuit with new R-410A Puron non-ozone depleting environmentally compliant refrigerant. • Provide all necessary materials, labor, and installation. • Provide,start-up and test of the system. Excludes: • Enlargement of the existing attic access hatch to allow for the removal/installation of the:air handlers, if required. *Upon acceptance,please date,sign by the"X"and return yellow copy with your deposit. KOLB MECHANICAL HEATING&AIR CONDITIONING In the event this account is forwarded to counsel for collection the purchaser shall be liable for all reasonable fees of Kolb Mechanical Corp., It is the responsibility of the Homeowner to have qualified Service Mechanics maintain heating and air conditioning equipment as required by man- ufacturer in order to preserve warranties. All equipment shall remain property of Kolb Mechanical Corp.,until fully paid All past due accounts shall be charged Interest of 1.5%per month. All payments Due Upon Receipt. =C V99P006 ,hereby to furnish material and labor—complete In accordance with above specifications,for the sum of: Base Total Options Total Grand Total Payment to be made as follows: AI material is guaranteed to be as spec6ed. An wA to be completed in a wafterae manner acood'u g to standard practices.Any alteration or deviation from above specrirations Involving extra Authorized casts will be exeaded any upon written orders,and will become an endra charge over and above the Signature estimate.All agreements contingent upon strikes,accidents or delays beyond our catlrol:tanner to carry rue,tornado and other necessary insurance. Our wwMrs are fully covered by Wodman's Note:This project may be Compensation Insurance. withdrawn by us If not accepted within 16 2tt¢ptame Df Ttollo811Y The above prices,specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Pffnt Name Date of Acceptance Signature Page No. 2 of 2 Pages 11500 Old Sound Avenue, PO Box 106 • O Mattituck, New York 11952 P 631-298-5527 1 F 631-298-5534 HEATING + COOLING www.koibmechanical.com PROPOSAL SUBMITTED TO PHONE DATE STREET JOB NAME 367 Riley Avenue 367 Riley Avenue CITY.STATE AND ZIP JOB LOCATION .. Mattituck NY 11952 Mattituck NY 11952 EMAIL ADDRESS CELL PHONE Fin m airc n trlu -on.com JZ/gs We hereby submit specifications and estimates for: Warranty: All work to be done in a professional-manner by trained installers and service _personnel.. • One-year parts.& labor service during normal business hours on above system. • Rheem Ten-.year factory limited parts warranty. • All-factory warranties honored. Total Investment: $ 4,200.00 *Upon acceptance,please date,sign by the"X"and return yellow copy with your deposit. KOLB MECHANICAL HEATING&AIR CONDITIONING In the event this account Is forwarded to counsel for collection the purchaser shall be liable for all reasonable fees of Kolb Mechanical Corp., It Is the responsibility of the Homeowner to have qualified Service Mechanics maintain heating and air conditioning equipment as required by man- ufacturer In order to preserve warranties. All equipment shall remain property of Kolb Mechanical Corp.,until fully paid AII past due accounts shall be charged Interest of'1.5%per month. All payments Due Upon Receipt. U1.9 TOP069 hereby to fumish material and labor-complete in accordance with above specifications,for the sum of: Base Total Options Total Four Thousand Two Hundred Dollars and xxj()Q - - - - - - - - - - - - - - - - srandTotal $4,200.00 Payment to be made as follows: 0500/6 Balance Due Up All material is guaranteed to be as specified. All work to be completed in a workmanrke in \ aocodmg to standard practices:Any alteration or deviall on from above specifications ImoMM edra In rized costs w9 be exeaded only upon wriCen orders,and will become an extra charge ova and above the Si naW estimate.M agreements contingent upon stnlms,accidents or delays beyond our conboL Owner to tarty fire.tomedo and other necessary insurance. Our wodmrs are fully covered by Workman''s may b Compensation Insurance. will by us it not accepted within 76 2krepfWne of VtD109(d The above prices,specifications and conditions are satisfactory an are hereby accepted. You'are authorized to Print Name do the work as specified. Payment will be made as outlined above, Dale of Acceptance K Signature FORM NO. P11-778 REV.2 Supersedes Form No.Pii-778 Rev.1 . AT t- E 14 --- -------- Equipped with • Comfort Contr012 System- •Serial communication enabled •Increased system reliability and efficiency 9?iesti ee •37+on-board diagnostic and operating codes S E R I E S •Active Protection`"with homeowner"Call for Service"alert 9 • Exclusive Design with dual 7-segment LED display The Rheem Prestige SeriesTm High Efficiency Two-Stage RPRL- JEC Heat Pump can provide year-round heating and cooling com- fort.The Rheem RHPL air-handler, equipped with auxiliary heat- ing elements for supplementary heat was designed especially for use with the Prestige SeriesTm heat pump.Together they deliver 3 ®�f stages of heat and 2 stages of cooling for precise temperature a � re - control and optimal energy efficiency. RPRL- J EC ■Industry's lowest profile design:33"maximum height Two-Stage Cooling/Three Stage Heating ■The Comfort ControP SystemTm provides over 37+ on-board Efficiencies ranging u to 17.SEER/13 EER/9.8 HSPF diagnostics and fault history codes for condensing units with g g p single-phase compressors by detecting system and electrical In certain matched systems. problems. The integrated diagnostics with Active ProtectionTm prevents compressor operation when potentially harmful condi- Four Models tions are detected. Sends"Call for Service"alert notification to Nominal Sizes 2, 3, 4&5 Tons the thermostat to alert the homeowner of required service. [7.03, 10.5, 14.07& 17.6 kW] ■Serial Communication Enhanced—When installed with a Serial Communicating Air Handler (RHPL-HM****JC) and user,inter- face control (RHC-TST501 CMMS) Series 500 thermostat this unit offers 4 or 2 wire installation,auto-configuration,and diag- nostic messaging with full communicating capability. ■Legacy Enabled — Unit can be conventionally wired using 24VAC with non-communicating Rheem air-handlers or furnaces _ with non-communicating thermostat. ■Features a 10-year conditional unit replacement warranty and 10-year parts warranty when properly installed with a new Rheem air handler or Rheem indoor coil with a Rheem gas fur- nace.See product warranty card for additional information. ■Reliable Two-Stage operation for precise temperature control and On-Demand dehumidification.When matched with ECM gas fur- _ i I nace or air-handler, the system adjusts airflow to help control ' humidity for unsurpassed comfort in the cooling mode. - - _ ■All controls are accessible by removing one service panel. _ Removable top grille provides access to the condenser.fan motor and condenser coil. ■Attractive, louvered wrap-around jacket protects the coil from ^? ' yard hazards and weather extremes. Top grille is steel rein- forced for extra strength. Cabinet is powder painted for all- weather protection. ■For quiet operation and improved efficiency, models feature an ECM two-speed condenser fan motor with a 3-blade outdoor fan. ■All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus. ■Dual Fuel capable with select thermostats. C U0 L usUnitarySmaIIHP sow 6.Q/F oa.�6tlb(sEEH) � . c+" 6.6 LISTED W �� � r�.o—Uau WMnw,yy�zr.o Certificate Number.30164 "Proper sizing and installation of equipment is critical to achieve optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria.Ask your Contractor for details or visit www.energystargov." FEATURES & BENEFITS OF THE COMFORT CONTROL2 SYSTEMTM '■The Rheem Exclusive Dual 7 Segment LED Display easily ■The Fault Recall feature will allow for the last six fault-codes shows system status codes and conditions. to be displayed,and will retain these codes even if power ■A Sealed Switch replaces the standard failure occurs. contactor and features optical control ■Built-in short-cycle protection allows the compressor to and latching restart easily without removing the oil from the compressor. mechanism.The ■A 30-second minimum run-time for every compressor call sealed switch pre- `;, allows the oil to return to the compressor. vents infiltration of ■Active Protection prevents the compressor from operating if insects and dust. p p p g A minimal switch- damage could occur. ing arc,by the ■The compressor and fan are optical control, controlled independently, offers greater reliability.The latching which reduces the starting load mechanism consumes less power while and light dimming. reducing chatter. ■A manual push-button is '* offered to operate the compres- w• ■The Status Indication and System Diagnostics feature thee- sor and fan for 5 seconds to mostat communication capability,built-in diagnostics,cur- allow for an operation check. rent sensing and high&low switch monitoring.The thermo- ■In order to save time and stat communication capability alerts the homeowner of any money,replacement automotive fuses can be utilized necessary service requirements. n instead of replacing the entire control board. Faster,more accurate service is pro- r vided with the built-in diagnostics,by providing the HVAC professional with I �ro � ti1� ��1{9�1 ► C41�'SC dependable information.In addition, high and low pressure-switch moni- tan -- toring prevents the system from oper- ating when damage could occur. aa .�_ 0% STANDARD FEATURES 0 Fti4aG 0in, RPRL-JEC Heat Pumps S'lwe'n 1. 2-stage operation in both cooling and heating mode. D% j 2. Scroll compressor is hermetically sealed and incorporates i internal high temperature motor overload protection, and 44 durable insulation on the motor windings. It is externally En" Level. Expeal",c0 d mounted on rubber grommets to reduce vibration and noise. 3. Compressors have an internal pressure relief assembly to TWO-STAGE SCROLL protect against excessive pressure differential. VV 4. All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations. COMPRESSOR 5. Cabinet is constructed of powder painted galvanized steel.The full wraparound louvered grille protects the coil The scroll compressor is the key to efficiency for this Rheem from damage. model. It's the latest in high-efficiency compressor technology. 6. Copper Tube—Aluminum Fin coils are used on all models. The advanced scroll compressor 9- --- 7. The control box is located in the top corner of the cabinet offers low noise and vibration providing for easy access through a service panel. characteristics and features - - ,i ' 8. Service valves are standard on all models. tolerance to liquid refrigerant and a 9. Field connections for power and control wiring are kept system contamination.The scroll separate. also has low start torque, 4` 10. Every unit is factory charged and run-tested. eliminating start problems in the 11. Separate compressor compartment for easy service access. field.And its unique design 12. Drawn, painted base pan for extra corrosion resistance and enables the RPRL-JEC Heat ,. sound reduction. Pump to perform efficiently, 13. The RPRL-JEC has a 10 year limited parts warranty, plus a quietly and reliably.All models All controls and compressor 10 year conditional unit replacement warranty.See the have a 10-year compressor are accessible for servicing by General Terms of Limited Warranty for more details. warranty as standard. removal of the service panel. 14. Hard Start Kits—Standard on all JEC models. 15. Enhanced compressor sound wrap is standard. 16. Control Box Cover. 17. The RPRL-JEC is shipped with a liquid line filter drier, (not-installed). 18. The RPRL-JEC features factory-installed auto-reset low and high pressure controls. 2 Rheem Heating, Cooling and Water Heating Accessories ■• Outdoor Thermostats— IN Blower Time Delay Control—RXMD-CO6. RXPT-A01-0ne outdoor thermostat in box. ■ Fossil Fuel Kits—Not required.See Rheem Thermostats RXPT-A02—One outdoor thermostat for mounting in box for use Specification Sheet(T11-001). with RXPT-A01 or A03. ■ Low Ambient Control—Cycles outdoor fan to maintain adequate RXPT-AO3-0ne outdoor thermostat with emergency Heat Relay condensing pressures assuring liquid refrigerant flow to the coil. wired and mounted in box. Allows low temperature operation in the cooling cycle down to 0°F RXPT-AO4—Two outdoor thermostats with emergency Heat Relay [-17.8°C]outdoor temperature.It is recommended that this control be wired and mounted in box. installed in units to be operated at outdoor ambient temperatures under 70oF[21eC](Model No.RXAD-A08) ■ Thermostats ■ Dual Fuel High Pressure Control—RXME-A01. This kit is required if this heat pump is installed in a dual fuel application. 100-Series* 200-Series* is Communicating 2 Wire Kit—RXM E-A02. Non-Programmable i Programmable This kit will allow the outdoor unit to communicate to the system with j only 2 wires. I.1_2 300-Series* 500-Series Deluxe - Communicating/ Programmable -� programmable 40 Special * I IMPORTANT: Special Applications/ t Programmable The Comfort Contro/2 SystemTM requires a communicating Unique RPRL-JEC Heat Pump,the RHPL-HM***JC Air Handler and Brand Model Descriptor series system Type the 500-Series Thermostat. Number (3 Characters) (3 Characters) (2 Characters) (2 Characters) Pratix RHC TST 101 GE MS TST=Thermostat 100=Non-Programmable 200=Programmable• GE=Gas10Mecbic 300=13eluxe Pmgrommeble HP=Heat Pump RHC=Rbeem MD=Modulating Fumece SS=SingleStage 400=Spedal Appllm0onal DF=Dual Fuel MS--Multi-stage Programmable UN=Unlvemal ACIHPlGE 500=Communlcatingl CWcommunlwting Pmgrammable *Photos are representative.Actual models may vary. For detailed thermostat match-up information, see specification sheet form number T11-001. NOTE: Requires"3 Heat/2 Cool"thermostat for Maximum Comfort. Model Number Identification R P R L — 024 J EC RHEEM REMOTE EFFICIENCY DESIGN COOLING ELECTRICAL VARIATIONS HEAT PUMP 16 SEER SERIES CAPACITY DESIGNATION EC=EQUIPPED WITH THE R 410A J=208/23OV-1-60 COMFORT 024=24,000 BTU/HR [7.03 kW] CONTROL2 SYSTEM" 036=36,000 BTU/HR[10.55 kW] 048=48,000 BTU/HR[14.07 kW] [ ]Designates Metric Conversions 060=60,000 BTU/HR[17.58 kW] Rheem Heat Pump System For all season home comfort, performance and energy conservation,choose a Rheem Prestige SeriesTM RPRL-JEC Series Heat Pump and with an RHPL-HM***JC or RHPL-HM**JAAir Handler. More than a reverse cycle air conditioner, it's a specially designed combination Winter/Summer comfort system using an indoor coil for heating and cooling. To choose an RHPL-HM***JC or RHPL-HM**JAAir Handler designed for use with the RPRL-JEC Heat Pump, refer to the Performance Data Tables and/or the air handler specification sheet. Rheem Heating, Cooling and Water Heating 3 Performance Data AHRI.Standard Conditions Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. AHRI Cooling Performance AHRI Healing Performance(70°F[21°C]Indoor) m 80°[26.5°Cl/67°F[19.5°C]WB Indoor Air ° ° Outdoor Air Outdoor Air Outdoor Model Numbers 95F[35C]DB Outdoor Air 47°F[8.5°C]DB/ 17°F[8.5°Cl DB/ 47°F[8.5°Cl DB/ 17°F[-8.5°Cl OB/ Unit Stage 43°F[6°Cl WB 15°F[-9.5°C]WB DOE 2 AHRI Ratings 43°F[6°C]WB 15°F[-9.5°C]WB tp RPRL- Net Sensible Net Latent Indoor Airflow Sound Region IV R: BTU/H[kW] BTU/H[kW] Total CFM[L/sl Rating HSPF ID Coil ID Air Mover Capacity SEER EER dB BTU/H NWI COP BTU/H[kWI COP BTU/H[kW] BTU/H[kW] Rev. 1 14,500[4.2] 4,100[1.2] 625[2951 71 17,200[5.0] 10,400[3.0] p 2/24/2010 3.54 2.54 17,200[5.0] 10,400[3.0] 9.05 0 2 17,850[5.2] 6,150[1.8] 775[3661 74 26,200[7.7] 17,000[5.0] 3 RCSM-H'2421 iD RHPL-HM2421 1 dehumid 13,800[4.0] 3,700[1.1] 24,000[7.0] 17.00 13.05 550[260] 71 cQ 2-dehumid 17,250[5.1] 6,150[1.81 675[319] 74 CL 1 11,200[3.3] 7,300[2.1] 600[283] 71 17,200[5.0] E17,200 3.0]RGFD O6?MCK? 2 17,750[5.2] 6,050[1.8] 23,800[7.0] 16.50 12.50 800[378] 74 26,200[7.7] 3.665.0] 2.56 17,200[5.0] 10,400[3.0] 9.65 1 11,200 13.31 7,300[2.1] 600[2B3] 71 17,100 15.0] 3.0]RGFD-07?MCK? 2 17,800[5.2] 6,200[7.8] 24,000[7.0] 16.50 12.60 g00[378] 74 26,200[7.7] 3.685.0] 2.58 17,100[5.0] 10,400[3.01 9.65 CD 1 11,05013.21 7,250[2.1] 5751271] 71 17,10015.01 3.0] cfl RGFE-06?MCK? 2 17,850[5.2] 6,150[1.8] 24,000[7.0] 16.50 12.80 g00[378] 74 26,200[7.7] 3.70 17,100[5.0] 2.60 17,100[5.0] 10,300[3.01 9.70 1 11,200[3.3] .7,400[2.2] 600[283] 71 17,100[5.0] 10,300[3.01 RGFE-07?MCK? 2 18,050[5.3] 6,150[1.8] 24,20017.11 17.00 12.90 825[3891 74 26,200[7.7] 3.70 17,100[5.01 2.58 17,100 15.0] 10,30013.01 9.70 1 11,200[3.3] 7,400[2.2] 600[2831 71 17,100[5.0] 3.70 10,300[3.0] RGGD O6?MCK? 2 17,850[5.2] 6,150[1.8] 24,000[7.0] 17.00 12.80 800[3781 74 26,200[7.7] 17,000[5.0] 2.60 17,100[5.0] 10,300[3.0] 9.70 1 11,200[3.3] 7,300[2.11 625[295] 71 17,100[5.0] 10,400[3.0] RGGD-07?MCK? 24,000[7.0] 17.00 12.70 3.68 2,58 17,100[5.0] 10,400[3.0] 9.70 2 17,800[5.2] 6,200[1.8] 800[378] 74 26,200[7.7] 17,100[5.0] 1 11,200[3.3] 7,400[2.2] 24,200[7.1] 17.00 13.00 625[295] 71 17,100[5.0] 3.70 10,300[3.0] 024JEC RGGE-O6?MCK? 2.60 17,100[5.0] 10,300[3.0] 9.70 2 18,05015.31 6,150[1.81 825[389] 74 26,200[7.7] 17,000[5.0] 1 11,05013.21 7,250[2.1] 575[271] 71 17,100[5.0] 10,300[3.0] RCFM-H*2417 RGGE-07?MCK? 24,000[7.0] 17.00 12.85 3.70 2.60 17,100[5.0] 10,300[3.0] 9.75 2 17,850 15.21 6,150[1.8] 800[378] 74 26,200[7.7] 17,000[5.0] 1 -11,200 13.31 7,400[2.2] 600[283] 71 17,100[5.0] 10,300[3.0] RGJD-O6?MCK? 24,000[7.0] 17.00 12.80 3.70 2.60 17,100[5.0] 10,300[3.0] 9.70 2 17,850[5.21 6,150[1.8] 800[378] 74 26,200[7.7] 17,000[5.0] 1 11,200[3.3] 7,300[2.1] 625[295] 71 17,100[5.0] 3.68 10,400[3.0] RGJD 07?MCK? 2 17,800[5.21 6,200[1.8] 24,000[7.0] 17.00 12.70 800[378] 74 26,200[7.7] 17,100[5.0] 2.58 17,100[5.0] 10,400[3.0] 9.70 1 11,200[3.3] 7,40012.2] 625[295] 71 17,100 15.0] 10,300[3.0] RGJF-06?MCK? 2 18,050[5.3] 6,150 11.8] 24,200[7.1] 17.00 13.00 825[389] 74 26,200 17.71 3.70 17,000[5.0] 2.60 17,100[5.0] 10,300[3.0] 9.70 1 11,050[3.2] 7,250[2.1] 57512711 71 17,100 15.01 10,30013.0] RGJF-O7?MCK? 24,000[7.0] 17.00 12.85 3.70 2.60 17,100[5.0] 10,300[3.0] 9.75 2 17,850[5.2] 6,150[1.8] 800[378] 74 26,200 17.71 17,000[5.0] 1 11,250[3.3] 7,350[2.2] 600[283] 71 17,10015.01 10,30013.01 RGLR-07?AMK? 2 17,900[5.2] 6,100[1.8] 24,000[7.0] 17.00 13.00 80013781 74 26,200 17.71 3.72 17,000[5.0] 2.62 17,100[5.0] 10,30013.01 9.75 1 11,150[3.3] 7,350[2.2] 60012831 71 17,200 15.0] 10,400[3.0] RGPR-05?BMK? 24,000[7.0] 16.50 12.80 3.70 2.60 17,200[5.0] 10,400[3.0] 9.65 2 17,850[5.2] 6,150[1.8] 77513661 74 26,200 17.71 17,100[5.0] RGRM-04?MAE? 1 11,200[3.3] 7,300[2.1] 23,800[7.0] 17.00 12.60 575[2711 71 17,100[5.01 3.68 10,400[3,0] 2.58 17,100[5.0] 10,400[3.0] 9.65 2 17,750[5.2] 6,050[1.8] 800[378] 1 74 26,200[7.7] 17,100[5,0] 0 Highest sales volume tested combination required by DOE test procedures. [ ]Designates Metric Conversions Performance Data-AHRI Standard Conditions (con It Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. AHRI Cooling Performance AHRI Heating Performance(70°F[21°Cl Indoor) 80°[26.5°Cl/67°F[19.5°Cl WB Indoor Air Outdoor Air Outdoor Air Outdoor Model Numbers 95°F[35°C]DB Outdoor Air 47°F[8.5°C]DB/ 17°F[-8.5°Cl DB/ 47°F[8.5°C]OB/ 17°F[-8.5°Cl OB/ Unit Stage AHRI Ratings Sound 43°F[6°C]WB 15°F[9.5°C]WB 43°F[6°C]WB 15°F[-9.5°C]WB DOE Region IV RPRL- Net Sensible Net Latent Indoor Airflow BTU/H[kW] BTU/H[kW] Total CFM[L/s] Rating HSPF ID Coil ID Air Mover Capacity SEER EER d6 BTU/H[kVd] COP BTU/H[kW] COP BTU/H[kWl BTU/H[kW] Rev. 1 11,200[3.3] 7,300[2.1] 600[283] 71 17,100[5.01 10,40013.01 2/24/2010 RGRM-06?MAE? 2 18,000[5.3] 6,200[1.8] 24,200[7.1] 17.00 12.75 825[389] 74 26,200[7.7] 3.68 17,100[5.01 2.58 17,100[5.0] 10,400[3.0] 9.70 RCFM H'2417 RGRM 07?MAE? 1 11,150[3.3] 7,350[2.2] 24,200[7.1] 16.50 12.50 625[295] 71 17,200[5.0] 362 10,500[3.1] 254 17,200[5.0] 10,500[3.1] 9.55 2 18,000[5.3] 6,200[1.8] 850[4011 74 26,400[7.7] 17,300[5.1] 1 11,550[3.4] 7,550[2.2] 750[3541 71 17,200[5.0] 10,500[3.1] RGTM-O6?MAE? 24,200[7.1] 16.50 12.85 3.68 2.58 17,200[5.0] 10,500[3.1] 9.60 2 18,000[5.3] 1 6,200[1.8] 825[389] 74 26,200[7.7] 17,100[5.0] 1 13,900[4.11 4,100[1.2] 625[295] 71 17,600[5.2] 10,900[3.2] RCFM-H'2417+RXMD-CO6 Coil Only 23,600[6.9] 14.50 11.65 3.52 2.48 17,600[5.2] 10,900[3.2] 9.10 2 17,450[5.11 6,15011.81 7751366] 74 26,600[7.8] 17,500[5.1] 1 11,200[3.3] 7,300[2.1] 600[283] 71 17,100[5.01 10,400[3.0] RGFD-06?MCK? 2 17,750[5.2] 6,050[1.8] 23,800 17.01 16.50 12.55 800[378] 74 26,200[7.7] 3.66 17100[5.0] 2.58 17,100[5.0] 10,400[3.0] 9.65 1 11,200[3.3] 7,300[2.1] 600[283] 71 17,100[5.0] 3.68 10,400[3.0] RGFD 07?MCK? 2 17,800[5.2] 6,200[1.8]' 24,000[7.0] 16.50 12.65 800[378] 74 26,200[7.7] 17,100[5.0] 2.58 17,100[5.0] 10,400[3.0] 9.70 1 11,050[3.2] 7,250[2.1] 575[2711 71 17,100[5.0] 10,300[3.0] RGFE-06?MCK? 24,000[7.0] 16.50 12.80 3.70 2.60 17,100[5.0] 10,300[3.0] 9.75 2 17,850[5.2] 6,150[1.8] 800[378] 74 26,200[7.7] 17,000[5.0] 1 11,20013.31 7,40012.2] 600[283] 71 17,100[5.0] 10,300[3.0] RGFE-07?MCK? 24,200[7.1] 17.00 12.95 3.70 2.60 17,100[5.01 10,300[3.0] 9.75 2 18,050[5.31 6,15011.81 825[389] 74 26,200[7.7] 17,000[5.0] 1 11,200[3.31 7,40012.21 600[283] 71 17,100[5.0] 10,300[3.0] 024JEC RGGD-06?MCK? 24,000[7.0] 17.00 12.85 3.72 2.60 17,100[5.01 10,300[3.0] 9.75 2 17,850[5.21 6,15011.81 800[378] 74 26,200[7.7] 17,000[5.0] 1 11,200[3.3] 7,300[2.1] 625[295] 71 17,100[5.0] 10,300[3.0] RGGD-07?MCK? 24,000[7.0] 17.00 12.75 3.70 2.60 17,100[5.0] 10,300[3.0] 9.70 2 17,800[5.2] 6,200[1.8] 800[378] 74 26,200[7.7] 17,100[5.0] S 1 11,200[3.3] 7,400[2.2] 625[295] 71 17,100 15.01 10,300[3.0] CD RCFM-H`2421 RGGE-06?MCK? 24,200[7.1] 17.00 13.05 3.72 2.60 17,100[5.0] 10,300[3.0] 9.75 CD 2 18,050[5.3] 6,150[1.8] 825[389] 74 26,200[7.71 17,000[5.0] 1 11,050[3.2] 7,250[2.1] 5751271] 71 17,100[5.01 10,300[3.0] CD RGGE-07?MCK? 2 17,850[5.2] 6,150[1.8] 24,00017.01 17.00 12.85 g00[378] 74 26,200[7.7] 3.72 17,000[5.0] 2.60 17,100[5.0] 10,300[3.0] 9.75 :' 1 11,200[3.3] 7,400[2.2] 600[283] 71 17,100[5.01 10,300[3.0] 9 RGJD-06?MCK? 24,00017.01 17.00 12.85 3.72 2.60 17,100[5.0] 10,300[3.0] 9.75 2 17,850[5.2] 6,150[1.8] 800[378] 74 26,200[7.7] 17,000[5.0] 0 1 11,200[3.3] 7,300[2.1] 625[295] 71 17,100[5.0] 10,300 13.01 2. RGJD-07?MCK? 24,000[7.0] 17.00 12.75 3.70 2.60 17,100[5.0] 10,300[3.0] 9.70 2 17,800[5.2] 6,200[1.8] 800[378] 74 26,200[7.7] 17,100[5.0] w 1 11,200[3.3] 7,400[2.2] 625[295] 71 17,100[5.0] 10,300[3.01 a RGJF-06?MCK? 24,200[7.1] 17.00 13.05 3.72 2,60 17,100[5.0] 10,300[3.0] 9.75 2 18,050[5.31 6,150[1.8] 825[389] 74 26,200[7.7] 17,000[5.0] 1 11,05013.21 7,250 12.1] 575[271] 71 17,100[5.0] 10,300[3.0] RGJF-07?MCK? 24,000[7.0] 17.00 12.85 3.72 2.60 17,100[5.0] 10,300[3.0] 9.75 2 17,85015.21 6,150[1.8] 800[378] 74 26,200[7.7] 17,000[5.0] m 1 11,250[3.31 7,350[2.21 600[283] 71 17,000[5.0] 10,300[3.0] w RGLR-07?AMK? 24,000[7.0] 17.00 13.00 3.74 2.62 17,000[5.0] 10,300[3.0] 9.80 2 17,900[5.2] 6,100[1.81 800[378] 74 26,000[7.6] 17,000[5.0] v, [ ]Designates Metric Conversions cn Performance Data AHRI Standard Conditions (con't.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. � AHRI Cooling Performance AHRI Heating Performance(70°F[21°C]indoor) m 80°[26.5°Cl/67°F[19.5°Cl WB Indoor Air Outdoor Outdoor Air Outdoor Air 47°F[8.5°C]BB/ 17°F[-8.5°Cl OB/ 3 Unit Model Numbers Stage 95°F[35°C]DB Outdoor Air 47°F[8.5°C]DB/. 17°F[8.5°C]DB/ = AHRI Ratings 43°F[6°C]WB 15°F[-9.5°Cl DB 43°F[6°C]WB 15°F[-9.5°Cl WB 60E CD RPRL- Net Sensible Net Latent Indoor Airflow Sound Region IV ID Coil 10 Air Mover BTU/H[kW] BTU/H IkWI Total SEER EER CFM[Us] Rating A BTU/H[kWI COP BTU/H[kWI COP BTU/H[kW] BTUAI[kW] HSPF Capacity Rev. 1 11,150[3.3] 7,350[2.2] 600[283] 71 17,100[5.0] 10,400[3.0] o 2124/2010 RGPR-05?BMK? 2 17,850[5.2] 6,150[1.g] 24,000 [7.0] 16.50 12.80 775[366] 74 26,200[7.7] 3.70 17 000[5.0] 2.60 17,100[5.0] 10,400[3.0] 9.65 1 11,200[3.3] 7,400[2.2] 600[283] 71 17,100[5.0] 10,300[3.0] RGPR-07?AMK? 2 17,850[5:2] 6,150[1.8] 24,000 [7.0] 17.00 12.90 800[378] 74 26,200[7.7] 3.72 17,000[5.0] 2.60 17,100[5.0] 10,300[3.0] 9.75 a 1 11,200[3.3] 7,300[2.1] 575[271] 71 17,100[5.0] 10,300[3.0] RGRM-04?MAE? 2 17,800[5.2] 6,200[1.8] 24,000 [7.0] 17.00 12.65 800[378] 74 26,200[7.7] 3.68 17,100[5.0] 2.58 17,100[5.0] 10,300[3.0] 9.70 CD RCFM-H'2421 1 11,200[3.3] 7,300[2.1] 600-[283] 71 17,100[5.0] 10,300[3.0] m 024JEC RGRM-06?MAE? 2 18,000[5.3] 6,200[7.8] 24,200 [7.1] 17.00 12.80 825[389] 74 . 26,200[7.7]_ 3.70 17,100[5.0] 2.58 17,100[5.0] 10,300[3.0] 9.70 1 11,150[3.3] 7,350[2.2] 625[295] 71 17,200[5.0] 10,400[3.0] c� RGRM-07?MAE7 2 18,000[5.3] 6,200[1.8] 24,200 [7.1] 16.50 12.55 850[401] 74 26,400[7.7] 3.64 17,200[5.0] 2.56 17,200[5.0] 10,400[3.0] 9.60 RGTM-06?MAE? 1 11,550[3.4] 7,550[2.2] 24,200 [7.1] 17.00 12.90 750[354] 71 17,200[5.0] 3.70 10,400[3.0] 2 60 17,200[5.0] 10,400[3.0] 9.60 2 18,050[5.3] 6,150[1.8] 825[389] 74 26,200[7.7] 17,100[5.0] RCFM H*2421+RXMD CO6 Coil Only 1 13,900[4.1] 4,100[1.2] 23,600 [6.9] 14.50 11.65 625[295] 71 17,600[5.2] 3 52 10,900[3.2] 248 17,600[5.2] 10,900[3.2] 9.10 2 17,450[5.1] 6,150[1.8] 775[366] 74 26,600[7.8] 17,500[5.1] 1 19,350[5.7] 6,450[1.9] 875[413] 71 24,200[7.111 15,300[4.5] 3.60 2.64 24,200[7.1] 15,300[4.5] 9.40 RCSM-H`3621 O RHPL-HM3621 2 25,700[7.5] 9,700[2.8] 35,400[10.4] 16.50 12.75 1200[566] 72 32,000[9.4] 20,000[5.9] 1-dehumid 18,400[5.4] 5,800[1.7] 750[354] 71 2-dehumid 24,850[7.3] 9,700[2.8] 950[448] 72 RGFD-06?MCK? 1 13,850[4.1] 11,550[3.4] 34,600[10.1] 15.00 11.45 875[413] 71 24,400[7.1] 314 15,600[4.6] 218 24,400[7.1] 15,600-[4.6] 8.65 2 25,050[7.3] 9,550[2.8] 1175[554] 72 32,800[9.6] 20,800[6.1] RGFD 07?MCK? 1 13,900[4.1] 11,500[3.4] 34,400[10.1] 15.00 11.30. 900[425] 71 24,400[7.1] 314 15,600[4.6] 218 24,400[7.1] 15,600[4.6] 8.70 2 25,000[7.3] 9,400[2.8] 1200[566] 72 32,800[9.6] 20,800[6.1] RGFE-06?MCK? 1 13,900[4.1] 11,500[3.4] 34,600[10.1], 15.50 11.50 875[413] 71 24,400[7.1] 316 15,500[4.5] 2.20 24,400[7.1] 15,500[4.5] 8.70 2 25,100[7.4] 9,500[2.8] 1200[566] 72 32,600[9.6] 20,600[6.0] 036JEC 1 13,900[4.1] 11,500[3.4] 875[413] 71 24,400[7.1] 3.12 15,600[4.6] RGFE 07?MCK? 2 25,000[7.3] 9,400[2.8] 34,400[10.1] 15.00 11.25 1225[578] 72 32,800[9.6] 20,800[6.1] 2.18 24,400[7.1] 15,600[4.6] 8.70 RCFM-H'3617 _ RGGE-06?MCK? 1 14,050[4.1] 11,750[3.4] 34,800[10.2] 15.50 11.75 925[437] 71 24,400[7.1] 3.20 15,500[4.5] 2.22 24,400[71] 15,500[4.5] 8.90 2 25,250[7.4] 9,550[2.8] 1200[566] 72 32,400[9.5] 20,400[6.0] RGGE-07?MCK? 1 13,900[4.1] 1 11,500[3.4] 34,800[10.2] 15.50 11.70 875[413] 71 24,400[7.1] 318 15,500[4.5] 222 24,400[7.1] 15,500[4.5] 8.75 2 25,200[7.4] 9,600[2.8] 1200[566] 72 32,600[9.6]. 20,600[6.0] RGJF-06?MCK7 1 14,050[4.1] 11,750[3.4] 34,800[10.2] 15.50 11.75 925[437] 71 24,400[7.1] 3 20 15,500[4.5] 2.22 24,400[7.1] 15,500[4.5] 8.90 2 25,250[7.4] 9,550[2.8] 1200[566] . 72 32,400[9.5] 20,400[6.0] 1 13,900[4.1] 11,500[3.4] 875[413] 71 24,400[7.1] 15,500[4.5] RGJF-07?MCK? 34,800[10.2] 15.50 11.70 3.18 2.22 24,400[7.1] 15,500[4.5] 8.75 2 25,200[7.4] 9,600[2.8] 1200[566] 72 32,600[9.6] 20,600[6.0] O Highest sales volume tested combination required by DOE test procedures. [ ]Designates Metric Conversions Performance Data AHRI Standard Conditions (con't.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. AHRI Cooling Performance AHRI Heating Performance(70°F[21°C]Indoor) BO°[26.5°C]/67°F[19.5°C]WB Indoor Air Outdoor Air Outdoor Air Model Numbers 95°F[35°C]DO Outdoor Air 47°F[8.5°CI r 17°F[-Outdoor A DB/ Outdoor 47°F[8.5°C]DB/ 17°F[•8.5°C]DB/ Unit Stage AHRI Ratings Sound 43°F[6°C]WB 15°F[-9.5°C]WB 43°F[6°C]WB 15°F[-9.5°C]WB DOE RPRL- NeI Sensible Net Latent Indoor Airflow Rating Region HSPF V ID Coil ID Air Mover BTU/1[kW] BTU/H[kW] Total SEER EER CFM[L/s]Capacity dB BTU/H[kW] COP BTU/H[kWl COP BTU/H[kW] BTU/H[kW] Rev. 1 13,850[4.1] 11,550[3.4] 925[437] 71 24,600[7.2] 15,700[4.6] 2/24/2010 RGRM-04?MAE? 2 25,050[7.3] 9,550[2.8] 34,600[10.1] 15.00 11.45 1200[566] 72 32,800[9.6] 3.14 20,800[6.1] 2.18 24,600[7.2] 15,700[4.6] 8.65 RGRM-067MAE? 1 13,850[4.1] 11,550[3.4] 34,600[10.1] 15.00 11.55 900[425] 71 24,400[7.1] 314 15,600[4.6] 218 24,400[7.1] 15,600[4.6] 8.70 2 25,100[7.4] 9,500[2.8] 1175[554] 72 32,800[9.6] 20,800[6.1] RCFM-H'3617 RGRM-07?MAE? 1 13,750[4.0] 11,450[3.4] 34,200[10.0] 14.50 11.05 95014481 71 24,600[7.2] 3 08 15,800[4.6] 214 24,600[7.2] 15,800[4.6] 8.55 2 24,900[7.3] 9,300[2.7] 1225[578] 72 33,000[9.7] 21,000[6.2] 1 14,350[4.2] 11,850[3.5] 1075[507] 71 24,600[7.2] 15,800[4.6] RGTM-O67MAE7 34,600[10.1] 15.00 11.45 3.16 2.20 24,600[7.2] 15,800[4.6] 8.60 2 25,050[7.3] 9,550[2.8] 1225[578] 72 32,600[9.61 1 20,800[6.1] RCFM-H'3617+RXMD-CO6 Coil Only 1 18,150 15.31 6,450[1.9] 34,200[10.0] 14.00 11.85 875[413] 71 24,800[7.3] 3.20 16,000[4.7] 2.22 24,800[7.3] 16,000[4.7] 8.55 2 24,700[7.2] 9,500[2.8] 1070[505] 72 31,800[9.3] 20,200[5.9] RGFD-06?MCK? 1 13,850[4.1] 11,550[3.4] 34,600[10.1] 15.00 11.50 B75[413] 71 24,400[7.1] 316 15,600[4.6] 2.20 24,400[7.1] 15,600[4.6] 8.70 2 25,100[7.4] 9,500[2.8] 1175[554] 72 32,600[9.6] 20,600[6.0] RGFD-07?MCK? 1 13,900[4.1] 11,500[3.4] 34,400[10.1] 15.00 11.40 90014251 71 24,400[7.1] 314 15,600[4.6] 218 24,400[7.1] 15,600[4.6] 8.70 2 25,050[7.3] 9,350[2.7] 1200[566] 72 32,800[9.6] 1 20,800[6.1] 1 14,000[4.1] 11,600[3.4] 850[401] 71 24,200[7.1] 15,300[4.5] RGFD-09?ZCM? 34,800[10.2] 16.00 12.25 3.28 2.28 24,200[7.1] 15,300[4.5] 9.05 2 25,300[7.4] 9,500[2.8] 1150[543]T 72 32,200[9.4] 20,200[5.9] 1 14,000[4.1] 11,600[3.4] 35,000[10.3] 16.00 12.15 850[401] 71 24,200[7.1] 3.26 15,300[4.5] 036JEC RGFD-107ZCM7 2.26 24,200 17.11 15,300[4.5] 9.00 2 25,400[7.4] 9,600[2.8] 1175[554] 72 32,200[9.4] 20,200[5.9] RGFE-06?MCK? 1 13,900[4.1] 11,500[3.4] 34,600[10.1] 15.50 11.55 875[413] 71 24,400[7.1] 3.16 15,500[4.5] 2.20 24,400[7.1] 15,500[4.5] 8.75 2 25,100[7.4] 9,500[2.8] 1200[566] 72 32,600[9.6] 20,600[6.0] 1 13,900[4.1] 11,500[3.4] 875[413] 71 24,400[7.1] 15,500[4.5] CD RGFE-07?MCK7 34,400[10.1] 15.50 11.30 3.14 2.18 24,400[7.1] 15,500[4.5] 8.75 CD RCFM H'3621 2 25,000[7.3] 9,400[2.8] 1225[578] 72 32,800[9.6] 20,800[6.1] 2 RGFE-09?ZCM7 1 14,000[4.1] 11,600[3.4] 35,000[10.3] 16.00 12.10 875[413] 71 24,200[7.1] 3 24 15,300[4.5] 2.26 24,200[7.1] 15,300[4.5] 9.00 w 2 25,400[7.4] 9,600[2.8] 1200[566] 72 32,200[9.4] 20,200[5.9] cQ RGFE-10?ZCM7 1 14,000[4.1] 11,600[3.4] 34,800[10.2] 16.00 11.95 900[425] 71 24,200[7.1] 3 24 15,400[4.5] 2.24 24,200[7.1] 15,400[4.5] 9.00 2 25,300[7.4] 9,500[2.8] 1225[578] 72 32,400[9;5] 20,400[6.0] 0 1 14,100[4.1] 11,700[3.4] 92514371 71 24,400[7.1] 15,500[4.5] RGGE-06?MCK7 34,800[10.2] 15.50 11.85 3.22 2.22 24,400[7.1] 15,500[4.5] 8.95 cfl 2 25,250[7.4] 9,550[2.8] 1200[566] 72 32,400[9.5] 20,400[6.0] !v 1 13,950[4.1] 11,450[3.4] 87514131 71 24,400 17.1] 15,500[4.5] n RGGE-07?MCK? 34,800[10.2] 15.50 11.75 3.20 2.22 24,400[7.1] 15,500[4.5] 8.75 2 25,250[7.4] 9,550[2.8] 1200[566] 72 32,600[9.6] 20,600[6.0] N 1 14,000[4.1] 11,600[3.4] 875[413] 71 24,200[7.1] 15,300[4.5] RGGE-09?ZCM? 35,000[10.3] 16.00 12.20 3.26 2.26 24,200[7.1] 15,300[4.5] 9.00 2 25,450[7.5] 1 9,550[2.8] 1225[578] 72 32,200[9.4] 20,200[5.9] m 1 14,000[4.1] 11,600[3.4] 875[413] 71 24,200[7.1] 15,400[4.5] RGGE-10?ZCM? 35,000[10.3] 16.00 12.10 3.26 2.26 24,200[7.1] 15,400[4.5] 9.00 2 25,400[7.4] 9,600[2.8] 1206[566] 72 32,200[9.4] 20,200[5.9] [ ]Designates Metric Conversions v Performance Data AHRI Standard Conditions (con't.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.. S AHRI Cooling Performance AHRI Heating Performance(70°F[21°CI Indoor) (D 80°[26.5°CI/67°F[19.5°Cl WB Indoor Air <D Outdoor Air Outdoor Air Outdoor Model Numbers 95°F[35°CI OB Outdoor Air 47°F[8.5°Cl OB/ 17°F[-8.5°CI DB/ 47°F[8.5°C]DB/. . 17°F[-8.5°C]DB/ = Unit Stage AHRI Ratings 43°F[6°CI WB 15°F[-9.5°Cl WB 43°F[6°CI WB. 15°F[-9.5°C]WB DOE �D RPRL- Net Sensible Net Latent Indoor Airflow Sound Region IV a: BTU/H[kWI BTU/H[kWl Total CFM[L/sl. Rating HSPF ID Coil ID Air Mover Capacity SEER EER dB BTU/H[kWl COP BTU/H[kWI COP BTU/H[kW] BTU/H[kW] Rev. 1 14,100[4.1] 11,700[3.4] 925[437] 71 24,400[7.1] 15,500[4.5] 0 2/24/2010 RGJF-O6?MCK? 2 25,250[7.4] 9,550[2.8] 34,800[10.2] 15.50 11.85 1200[566] 72 32,400[9.5] 3.22 .20,400[6.0] 2.22 24,400[7.1] 15,500[4.5] 8.95 cc RGJF-07?MCK7 1 13,950[4.1] 11,450[3.4] 34,800[10.2] 15.50 11.75 875[413] 71 24,400 17.11 3 20 15;500[4.5] 2.22 24,400[7.1] 15,500[4.5] 8.75 2 25,250[7.4] 9,550[2.8] 1200[566] 72 32,600[9.6] 120,600[6.0] Q 1 14,000[4.1] 11,60013.41, 875[413] 71 24,200[7.1] 15,300[4.5] RGJF 097ZCM? 2 25,450[7.5] 9,550[2.8] 35,000[10.3] 16.00 12.20 1225[578] 72 32,20019.41 3.26 20,200[5.9] 2.26 24,200[7.1] 15,300[4.5] 9.00 m 1 14,000[4.1] 111,600[3.4] 875[413] 71 24,26017.11 15,400[4.5] . = RGJF-10?ZCM? 35,000[10.3] 16.00 12.10 3.26 2.26 24,200[7.1] 15,400[4.5] 9.00 CD 25,400[7.4] 9,600[2.8] 1200[566] 72 32,20019.41 20,200[5.9] 1 13,850[4.1] 11,550[3.4] 925[437] 71 24,40017.11 15,600[4.6] o� RGRM-04?MAE? 2 25,100[7.4] 9,500[2.8] 34,600[10.1] 15.00 11.45 1200[566] 72 32,800[9.6] 3.14 20,800[6.1] 2.18 24,400[7.1] 15,600[4.6] 8.70 1 13,850[4.1] 11,550[3.4] 900[425] 71 24,400[7.1]. 15,600[4.6] RGRM-06?MAE? 2 .25,100[7.4] 9,500[2.8] 34,600[10.1] 15.00 11.55 1175[554] 72 .32,800[9.6] 3•16 20,800[. 2.20 24,400[7.1] 15,600[4.6] 8.70 1 13,750[4.0] 11,450[3.4] 950.[448] 71 24,600[7.2] 15,800[4.6] RCFM-H`3621 RGRM-07?MAE? 34,200[10.0] 14.50 11.05 3.08 2.14 24,600[7.2] 15,800[4.6] 8.55 036JEC 2 24,850[7.31 9,350[2.7] 1225[578] 72 -33,00019.71 21,000[6.2] RGRM-07?YBG? 1 13,900[4.1] 11,500[3.4] 34,400[10.1] 15.00 11.25 850.[401] 71 24,400[7.1] 312 15,500[4.5] 218 24,400[7.1] 15,500[4.5] 8.70 2 25,000[7.31 9,400[2.8] 1200[566] 72 32,800 19.61 20,800.[6.1] 1 13,900[4.1] 11,500[3.4] 950[448] 71 24,40017.11 15,500[4.5] RGRM-09?ZAJ? 2 25,300[7.4] 9,500[2.8] 34,800[10.21 15.50 11.90 1225[578] 72 32,400[9.5] 3.22 20,400[6.0] 2.22 24,400[7.1] 15,500[4.5] 8.90 RGRM-10?ZAJ? 1 13,950[4.1] 11,650[3.4] 34,800[10.2] 15.50 12.05 875[413] 71 24,200[7.1] 3 24 15,400[4.5] 2.24 24,200[7.1] 15,400[4.5] 8.95 2 25,200[7.4] 9,600[2.8] 1150[5431 72 32,200[9.4] 20,200[5.9] - - - - - - - 1 - 14,350[4.2] 11,850[3.5]- - - - - - 1075[5071 -71-- -24,600[7.2] - -151800[4.61- - RGTM-06?MAE? 2 25,100[7.4] 9,500[2.8] 1225[578] 72 32,600[9.6] 20,600[6.0]34,600[10.1] 15.00 11.50 3.16 2.20 24,600[7.2] 15,800[4.6] 8.60 RGTM-07?RBG? 1 14,200[4.2] 11,800[3.5] 35,400[10.4]. 16.00 12.20 950[448] 71 24,200[7.11 3.24 15,400[4.5] 2.24 24,200[7.1] 15,40014.51 8.95 2 25,650[7.5] 1 9,750[2.9] 1275[6021 72 32,200[9.4] 20,200[5.9] RGTM-09?ZAJ? 1 14,250[4.21 11,750[3.4] 35,000[10.31 16.00 12.15 975[460] 71 24,200[7.1] 326 15,400[4.51 226 24,200[7.11 15,400[4.51 8.95 2 25,400[7.4] 9,600[2.8] 1225[578] 72 32,200[9.4] 20,200[5.91 1 18,350[5.4] 6,450[1.9] 875[4131 71- 24,800[7.3] 16,090[4.71 RCFM-H'3621+RXMD-006 Coil Only 34,400[10.1] 14.50 11.70 3.16 2.20 24,800[7.31 16,000[4.7] 8.55 2 24,800[7.3] 9,600[2.8] 1150[5431 72 1 32,400[9.5] 20,400[B.0] - [ ]Designates Metric Conversions Performance Data AHRI Standard Conditions (con't.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. AHRI Cooling Performance AHRI Heating Performance(70°F[21°C]Indoor) 80°[26.5°C]/67°F[19.5°C]WO Indoor Air Outdoor Air Outdoor Air Model Numbers 95°F[35°C]DB Outdoor Air 47°F[8.5°C]DB/ 17°F[-8.5°Cl DB/ Outdoor 47°F[8.5°C]DB/ 17°F[8.5°C]DB/ Unit Stage AHRI Ratings Sound 43°F[6°C]WB 15°F[-9.5°C]WB 43°F[6°Cl WB 15°F[-9.5°Cl WB Region IV DOE RPRL- Net Sensible Net Latent Indoor Airflow BTU/H IkW] BTU/H[kW] Total CFM[L/s] Rating HSPF ID Coil ID Air Mover Capacity SEER EER dB BTU/H[kW] COP BTU/H IkWI COP BTU/H[kW] BTU/H[kW] Rev. 1 26,650 [7.8] 8,750[2.6] 1200[566] 71 1 33,400 [9.8] 18,600[5.4] 2/24/2010 2 35,100[10.31 11,900[3.5] 1625[767] 72 48,000[14.1] 420 30,200[8.8] 2.52 33,400[9.8] 18,600[5.4] 9.05 RCSM H'4824 i0 RHPL HM4824 1-dehumid 24,000 [7.0] 9,800[2.9] 47,000[13.8] 16.00 12.25 1000[472] 71 2-dehumid 33,350 [9.8] 14,050[4.11 1275[602] 72 RGFD-09?ZCM? 1 19,800 [5.8] 15,200[4.5] 46,000[13.5] 14.50 11.15 1150[543] 71 33,800 [9.91 3.84 19,000[5.6] 2.48 33,800[9.91 19,000[5.61 9.30 2 34,450[10.1] 11,550[3.4] 1600[7551 72 49,000[14.4] 31,200[9.11 1 19,750 [5.8] 15,050[4.4] 46,000[13.5] 14.00 10.85 1175[554] 71 33,800 [9.9] 3.78 19,100[5.6] RGFD-10?ZCM? 2.44 33,800[9.9] 19,100[5.6] 9.25 2 34,400[10.1] 11,600[3.4] 1625 17671 72 49,500[14.5] 31,400 19.21 RGFE-09?ZCM? 1 19,750 [5.8] 15,050[4.4] 46,000[13.5] 14.00 10.95 1200[5661 71 33,800 [9.9] 3.80 19,100 15.61 2.46 33,800[9.91 19,100[5.6] 9.25 2 34,300[10.0] 11,700[3.4] 1600[755] 72 49,000[14.4] 31,400[9.2] 1 19,700 [5.8] 15,100[4.4] 1225[578] 71 33,800 19.9j 3.78 19,100[5.6] RGFE-10?ZCM? 2 34,400[10.11 11,600[3.4] 46,000[13.5] 14.00 10.85 1600[755] 72 49,500[14.51 31,400[9.2] 2.44 33,800[9.9] 19,100[5.6] 9.20 1 19,800 [5.81 15,200 14.51 46,000[13.5] 14.00 10.90 1175[554] 71 33,800 [9.9] 3.78 19,000[5.6] RGGD 09?ZCM? 2 34,400[10.11 11,600[3.4] 1675[790] 72 49,500[14.5] 31,400[9.2] 2.44 33,800[9.9] 19,000[5.6] 9.30 RGGD-10?ZCM? 1 19,800 [5.8] 15,200[4.5] 46,000[13.5] 14.00 10.95 1175[554] 71 33,800 [9.91 3.80 19,000[5.6] 2.46 33,800[9.91 19,000[5.61 9.30 2 34,300[10.0] 11,700[3.4] 1625[767] 72 49,000[14.4] 31,400[9.2] 1 19,750 [5.8] 15,050[4.4] 1225[5781 71 33,800 [9.9] 19,000[5.6] 048JEC RGGE-09?ZCM? 46,000[13.5] 14.00 11.10 3.84 2.48 33,800[9.9] 19,000[5.6] 9.30 2 34,400[10.1] 11,600[3.4] 1600[7551 72 49,000[14.4] 31,200[9.11 1 19,750 [5.8] 15,050[4.4] 1200[5661 71 33,800 [9.9] 19,100[5.6] RCFM-H'4821 RGGE-10?ZCM? 46,000[13.5] 14.00 11.00 3.80 2.46 33,800[9.9] 19,100[5.6] 9.25 2 34,300[10.0] 11,700[3.4] 1600[755] 72 49,000[14.4] 31,400[9.2] S 1 19,800 [5.8] 15,200[4.5] 1175[5541 71 33,800 [9.9] 19,000[5.6] -RGJD-09?ZCM? 46,000[13.5] 14.00 10.95 3.78 2.44 33,800[9.9] 19,000[5.6] 9.30 CD 2 34,400[10.1] 11,600[3.4] 1675[790] 72 49,500[14.5] 31,40019.21 1 19,800 [5.8] 15,200[4.5] 1175[554] 71 33,800 [9.9] 19,000 15.61 CD RGJD-10?ZCM? 2 34,350[10.1] 11,650[3.4] 46,000[13.5] 14.50 11.00 1625[767] 72 49,000[14.4] 3.82 31,200[9.1] 2.46 33,800[9.91 19,000[5.6] 9.30 1 19,750 [5.8] 15,050[4.4] 1225[578] 71 33,800 [9.9]. 19,000 15.61 co RGJF-09?ZCM? 46,000[13.5] 14.00 11.15 3.84 2.48 33,800[9.9] 19,000[5.6] 9.30 2 34,450[10.1] 11,550[3.4] 1600(755] 72 49,000[14.4] 31,200[9.1] O 1 19,750 [5.8] 15,050 14.41 1200[566] 71 33,800 [9.9] 19,100 15.61 2. RGJF-10?ZCM? 46,000[13.51 14.00 11.00 3.82 2.46 33,800[9.9] 19,100[5.61 9.25 2 34,350 110.11 11,65013.41 1600[755] 72 49,000[14.4] 31,200[9.1] N 1 19,800 [5.8] 15,200[4.5] 1225[578] 71 33,600 [9.8] 18,900[5.51 o RGLR-07?BRQ? 46,500[13.61 14.50 11.45 3.92 2.50 33,600[9.8] 18,900[5.5] 9.35 2 34,750[10.21 11,75013.41 1625[767] 72 49,000[14.4] 30,800[9.01 y 1 19,850 [5.8] 15,15014.41 1200[566] 71 33,600 [9.8] 18,900[5.5] RGLR-10?BRM? 46,000[13.51 14.50 11.50 3.94 2.52 33,600[9.8] 18,900[5.5] 9.40 2 34,300110.01 11,700[3.4] 1575[743] 72 48,500114.21 30,800[9.0] 1 19,850 [5.8] 15,150[4.4] 1225[578] 71 33,600 [9.8] 18,900[5.5] 3 RGPR 07?BRQ? 46,500[13.6] 14.50 11.55 3.92 2.52 33,600[9.8] 18,900[5.5] 9.40 2 34,800110.21 11,700[3.4] 1625[7671 72 48,500[14.21 30,800[9.0] `Q O Highest sales volume tested combination required by DOE test procedures. (o [ ]Designates Metric Conversions o Performance Data AHRI Standard Conditions (con't.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. AHRI Coaling Performance AHRI Heating Performance(70°F[21°C1 Indoor) s 80°[26.5°Cl/67°F[19.5*Cl WO Indoor Air m Model Numbers 95°F[35°Cl OB Outdoor Air Outdoor Air Outdoor Air 47°F(B.5°C]DB/ 17°F[8.5°Cl DB/ N Outdoor 47°F[8.5°Cl DII 17°F[-8.5°Cl OB/ - 3 Unit Stage AHRI Ratings 43°F[6°C]WB 15°F[-9.5°C1 WB 43°F[6°C]WB 15°F 1-9.5°C1 WO DOE = RPRL- Net Sensible Net Latent Indoor Airflow Sound Region IV CD BTU/H[kW] BTU/H[kW] Total CFM[L/s] Rating HSPF pr ID Coil ID Air Mover SEER EER dB BTU/H[kW] COP BTU/H[kW] COP BTU/H[kWl BTU/H[kW] Capacity Rev. 1 19,800 [5.8] 15,200[4.5] 120015661 71 33,600 [9.8] 19,000[5.61 C- 2/24/2010 RGPR-10?BRM? 2 34,350110.1] 11,650[3.4] 46,000[13.5] 14.50 11.30 1625 17671 72 49,000114.4] 3.88 31,000[9.11 2.50 33,600 19.81 19,00015.6] 9.35 0 1 19,650 [5.8] 14,950[4.4] 1225[5781 71 34,000[10.0] 19,200[5.61 RGRM-09?ZAJ? 2 34,350[10.1] 11,650[3.4] 46,000[13.51 13.50 10.75 1625[767] 72 49,500[14.5] 3.74 31,600[9.3] 2.42 34,000[10.01 19,200[5.6] 9.15 iy a 46,000[13.5] 14.00 10.80 3.74 1 19,700 [5.8] 15,100[4.4] 1150[5431 71 33,800 19.9] 19,100[5.6] RCFM-H*4821 RGRM-10?ZAJ? 2.42 33,800 [9.9] 19,100[5.6] 9.20 w 2 34,350[10.1] 11,650[3.4] 1600[755] 72 49,500[14.5] 31,600[9.3] m 1 20,050 [5.9] 15,350[4.5] 1325[625] 71 34,000[10.0] 19,200[5.6] RGTM-07?RUG? 46,000[13.5] 14.00 11.05 3.82 2.46 34,000[10.0] 19,200[5.6] 9.20 2 34,300[10.0] 11,700[3.4] 1675[790] 72 49,000[14.4] 31,40019.2] 1 19,900 [5.8] 15,100[4.4] 1250[590] 71 33,800 [9.91 19,100[5.6] RGTM-09?ZAJ? 2 34,350[10.1] 11,650[3.4] 46,000[13.5] 14.00 11.05 1600[755] 72 49,000[14.4] 3.82 31,200[9.1] 2.46 33,800 [9.9] 19,100[5.6] 9.25 RCFM H*4821+RXMD C06 Coil Only 1 25,050 17.31 8,750[2.6] .45,500[13.3] 13.50 11.45 1200[566] 71 34,400[10.11. 3.88 19,60015.7] 2 50 34,400[10.1] 19,600[5.7] 9.00 2 33,800 19.91 11,700[3.4] 1475[696] 72 48,000[14.1] 30,400[8.9] 1 19,800 [5.8] 15,200 14.5] 1150 15431 71 33,800 [9.9] 19,000[5.6] RGFD-09?ZCM? 46,000[13.5] 14.50 11.15 - 3.84 2.48 33,800 [9.9] 19,000[5.6] 9.30 2 34,450110.1] 11,550[3.41 1600[755] 72 49,000114.4] 31,200[9.11 1 19,750 [5.8] 15,050[4.4] 1175 15541 71 33,800 [9.9] 3.78 19,100[5.6] RGFD 10?ZCM? 2 34,400110.1] 11,600[3.4] 46,000[13.5] 14.00 10.85 1625[767] 72 49,500[14.5] 31,400[9.2] 2.44 33,800 [9.9] 19,100[5.6] 9.25 1 19,800 [5.8] 15,000[4.4] 1225[578] 71 33,800 [9.9] 19,000[5.6] 048JEC RGFD-12?RCM? 46,500[13.6] 14.00 11.40 3.88 2.50 33,800 [9.9] 19,000[5.6] 9.30 2 34,700[10.2] 11,800[3.5] 1650 1779] 72 49,000[14.4] 31,000[9.1] 1 19,750 [5.8] 15,050[4.4] 1200 15661 71 33,800 [9.9] 3.80 19,100[5.6] RGFE 09?ZCM? 2 34,300[10.0] 11,700[3.4] 46,000[13.5] 14.00 10.95 1600[755] 72. 49,000[14.4] 31,400[9.2] 2.46 33,800 [9.9] 19,100[5.6] 9.25 1 19,700 [5.8] 15,100[4.4] 1225 15781 71 33,800 19.9] 3.78 19,100[5.6] RGFE 10?ZCM? 2 34,400[10.1] 11,600[3.4] 46,000[13.5] 14.00 10.85 1600[755] 72 49,500[14.5] 31,400[9.2] 2.44 33,800 [9.9] 19,100[5.6] 9.20 1 19,800 [5.8] 15,000[4.4] 1225[578] 71 33,800 [9.9] 19,000[5.61 RCFM-H*4824 RGFE-12?RCM? 46,000[13.51 14.00 11.15 3.84 2.48 33,800 [9.9] 19,00015.6] 9.30 2 34,250[10.0] 11,750[3.4] 1625[767] 72 49,000[14.4] 31,200[9.1] 1 19,800 [5.8] 15,200[4.5] 11751554] 71 33,800 [9.9] 3.78 19,000[5.6] RGGD 09?ZCM? 2 34,400[10.11 11,600[3.4] 46,000[13.5] 14.00 10.90 1675[790] 72 49,500[14.51 31,400[9.2] 2.44 33,800 [9.9] 19,000[5.6] 9.30 1 19,800 [5.8] 15,200[4.5] 117515541 71 33,800 [9.9] 3.80 19,000[5.6] RGGD 10?ZCM? 2 34,300[10.01 11,700[3.4] 46,000[13.5] 14.00 10.95 16251767] 72 49,000[14.41 31,400[9.2] 2.46 33,800 [9.9] 19,000[5.6] 9.30 1 19,800 [5.81 15,200[4.5] 1225[578] 71 33,600 [9.8] 18,900[5.5] RGGD-12?RCM? 46,000[13.5] 14.50 11.20 3.86 2.48 33,600 [9.8] 18,900[5.5] 9.35 2 34,300[10.01 11,700[3.4] 1650 1779] 72 49,000[14.4] 31,200[9.1] 1 19,750 15.81 15,050[4.4] 1225[578] 71 33,800 [9.9] 19,000[5.6] RGGE-09?ZCM? 46,000[13.5] 14.00 11.10 3.84 2.48 33,800 [9.9] 19,000[5.6] 9.30 2 34,400[10.11 11,600[3.4] 1600[755] 72 49,000[14.4] 31,200[9.1] RGGE-10?ZCM? 1 19,750 15.8] 15,050[4,41 46,000[13.51 14.00 11.00 1200[566] 71 33,800 [9.9] 380 19,100[5.6] 2.46 33,800 [9.9] 19,100[5.61 9.25 2 34,300[10.0] 11,700[3.4] 1600[755] 1 72 49,000[14.4] 31,400[9.2] [ ]Designates Metric Conversions Performance Data AHRI Standard Conditions-.(con't.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. AHRI Cooling Performance. AHRI Heating Perlormance(70°F[21°Cl Indoor) 80°[26.5°C]/67°F.[19.5°Cl WB Indoor Air Outdoor Air Outdoor Air Model Numbers 95°F[35°Cl DB Outdoor Air q7°F[8.5°C]r 17°F[-Outdoor A DB/ Outdoor 47°F[8.5°Cl DB/ 17°F[-8.5°C]DB/ Unit Stage AHRI Ratings 43°F .5*C WB 15°F[-9.5°C]WB 43°F[6°C]WB 15°F[-9.5°C]WB DOE RPRL- Net Sensible Net Latent Indoor Airflow Sound Region IV BTU/H[kW] BTU/H[kW] Total CFM[L/s] Rating HSPF / ID Coil ID'Air Mover Capacity SEER EER dB -BTU/H[kW] COP BTU/H[kW] COP BTU/H[kW] BTU/H[kW] Rev. 1 19,850 [5.8] 15,150[4.4] 1200[566] 71 33,600 [9.8] 18,900[5.5] 2/24/2010 RGGE-12?RCM? 46,000[13.5] 14.50 11.45 3.92 2.52 33,600 [9.8] 18,900[5.5] 9.40 2 34,250[10.0] 11,750[3.4] 1575[743] 72 49,000[14.41 30,800[9.0] 1 19,800 [5.8] 15,200[4.5] 1175[554] 71 33,800 [9.9]. 19,000[5.6] RGJD-09?ZCM? 2 34,400[10.1] 11,600[3.4] 46,000[13.5] 14.00 10.95 1675[790] 72 49,500[14.5] 3•78 31,400[92] 2.44 33,800 [9.9] 19,000[5.6] 9.30' . RGJD 10?ZCM? 1 19,800 [5.8] 15,200[4.5] 46,000.[13.5] 14.50 11.00 1175[554] 71 33,800 [9.9] 3 82 19,000[5.6] 2 46 33,800 [9.9] 19,000[5.6] 9.30 2 34,350[10.11 11,650[3.4] 1625[767] 72 49,000[14.4] 31,200[9.1] 1 19,850 [5.8] 15,150[4.4] 1225[578] 71 33,600 [9.8] 18,900[5,5] RGJD-12?RCM? 46,000[13.5] 14.50 11.25 3.86 2.48 33,600 [9.8] 18,900[5.5] 9.35 2 34,300[10.0] 1 11,700[3.4] 1650[779] 72 49,000[14.4] 31,000[9.1] 1 19,750 [5.8] 15,050[4.4] 1225[578] 71 33,800 [9.9] 19,000[5.6] RGJF-09?ZCM? '46,000[13.5] 14.00 11.15 3.84. 2.48 33,800 19.91 19,000[5.6] 9.30 2 34,450[10.1] 11,550[3.4] 1600[755] 72 49,000[14A] 31,200[9.1] 1 19,750 [5.8] 15,050 14.41 1200[566] 71 33,800 [9.9] 19,100[5.6] RGJF-10?ZCM? 2 34,350[10.1] 11,650[3.4] 46,000[13.5] 14.00 11.00 1600[755] 72 49,000[14.4] 3.82 31,200[9.1] 2.46 33,800 [9.9] 19,100[5.6] 9.25 RGJF-12?RCM? 1 19,850 [5.8] 15,150[4.4] 46,000[13.5] 14.50 11.50, 1200[566]. 71 33,600 [9.8] 3 92 18,900[5.5] 2.52 33,600 [9.8] 18,900[5.5] 9.40 2 34,300[10.0] 11;700[3.4] 1575[743] 72 48,500[14.21 30,800[9:0] 1 19,800 [5.8] 15,200[4.5] 1225[578] 71 33,600 [9.8] 18,900[5.5] RGLR-07?BRO? 46,500[13.6] 14.50 11.45 3.92 2.50 33,600 [9.8] 18,900[5.5] 9.35 2 34,750[10.21 11,750[3.4] 1625[767] 72 49,000[14.41 30,800[9.0] 1 19,850 15.81 15,150[4.4] 1200[566] 71 33,600 [9.8] 18,900[5.5] 048JEC RCFM-H*4824 RGLR-10?BRM? 46,000[13.51 14.50 11.50 3.94 2.52 33,600 [9.8] 18,900[5.5] 9.40 2 34,300[10.0] 11,700[3.4]. 1575.[743] 72 48,500[14.2] 30,800[9.0] 1 19,850 [5.8] 15,150[4.4] 1200[566] 71 .33,600 [9.8] 18,800[5.5] - - - - - - - - RGLR-12?ARM? 46;500[13:6]- 14.50 11:65 3:94 2.52 -33,600--[9.8] 18;800[5.5] 9:40 2 34,650[10.21 11,850[3.5] 1600[755] 72 48,500[14.21 30,800[9.0] CD 1 19,850 [5.8] 15,150[4.4] 1225[578] 71 33,600 [9.8] 18,900[5.5] CD RGPR 07?BR(1? 2 34,800[10.2] 11,700[3.4] 46,500,[13.6] 14.50 11.55 1625[767] 72 48,500[14.2] 3 92 30,800[9.0] 2.52 33,600 [9.8] 18,900[5.5] 9:40 3 2 1 19,800 [5.8] 15,200[4.5] 1200[566] 71 33,600 [9.8] 19,000[5.6] CD RGPR-10?BRM? 46,000[13.5] 14.50 11.30 3.88 2.50 33,600 [9.8] 19,000[5.6] 9.35 w 2 34,350[10.1] 11,650[3.4] 1625[767] 72 49,000[14.4] 31,000[9.1] RGPR-12?ARM? 1 19,850 [5.8] 15,150[4.4] 46,000[13.5] 14.50 11.60 1250[590] 71 33;600 [9.8] 3.94 18,900[5.5] 2.52 33,600 [9.8] 18,900[5.5] 9.40 0 2 34,350[10.1] 11,650[3.4] 1575[743] 72 48,500[14.2] 30,800[9.0] 1 19,650 [5.8] 14,950[4.4] 1225[578] 71 34,000[10.0] 19,200[5.6] RGRM 09?ZAJ? 2 34,350[10.1] 11,650[3.4] 46,000113.5] 13.50 10.75 1625[767] 72 49,500[14.5] 3.74 31,600[9.3] 2.42 34,000[10.0] 19,200[5.6] 9.15 1 19,700 [5.8] 15,100[4.4] 1.1501543] 71 33,800 [9.9] . 19,100[5.6] o RGRM-10?ZAJ? 46,000[13.5] 14.00 10.80 3.74 2.42 33,800 19.91 19,100[5.6] 9.20 2 34,350 110.11 11,650[3.4] 1600[755] 72 49,500[14.5] 31,600[9:3] 1 19,750 [5.8] 15,050[4.4] 1225[578] 71 33,800 [9.9] 19,100[5.6] CDRGRM-12?RAJ? 46,000[13.5] 14.00 11.20 3.84 2.46 33,800 [9.9] 19,100[5.6] 9.25 = 2 34,250[10.0] 11,750[3.4] 1625[767] 72 49,000[14.4] 31,200[9.1] CD 1 20,050 [5.9] 15,350[4.5] 1325[625] 71 34,000[10.0] 19,200[5.6] RGTM 07?RBG7 2 34,300[10.0] �11,700[3.4], 46,000[13.5] 14.00 11.05 1675[790] 72 49,000[14.41 3.82 31,400[9.2] 2.46 34,000[10.0] 19,200[5.6] 9.20 [ ]Designates Metric Conversions 1 1 N Performance Data AHRI Standard Conditions (con't.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. AHRI Cooling Performance AHRI Heating Performance(70°F[21°C]Indoor) 80°[26.5°C]/67°F[19.5°C]WB Indoor Air CD Model Numbers 95°F[35°C]DBOutdoorAir Outdoor Air Outdoor Air (D Outdoor 47°F[8.5°C]DB/ 17°F[-8.5°C]DB/ 47-F[8.5oC WB/ 15°F[-9.5°C]O B DOE 3 Unit Stage AHRI Ratings 43°F[6°C]WB 15°F[-9.5°C]WB = RPRL- Net Sensible Net Latent Indoor Airflow Sound o Region IV CD BTU/H[kW] BTU/H[kW1 Total CFM[L/sj Rating HSPF ID Coil ID Air Mover Capacity SEER EER dB BTU/H[kWI COP BTU/H[kW] COP BTU/H[kW] BTU/H[kW] 9 Rev. 1 19,900 [5.8] 15,100[4.4] 1250[5901 71 33,800 [9.9] 19,100 15.6] C- 2/24/2010 RGTM-09?ZAJ? 2 34,350[10.1] 11,650[3.4] 46,000[13.5] 14.00 11.05 1600[755] 72 49,000[14.4] 3.82 31,200 [9.1] 2.46 33,800 [9.9] 19,100[5.6] 9.25 p RCFM-H•4824 1 19,950 [5.8] 15,250[4.5] 1275[6021 71 33,800 [9.91 19,100 [5.6] 048JEC RGTM-10?RBJ? 46,500[13.61 14.00 11.20 3.86 2.48 33,800 19.9] 19,100[5.6] 9.25 2 34,700[10.2] 11,B00[3.5] 1675[790] 72 49,000 114.4] 1 31,200 [9.1] N CL RCFM-H'4824+RXMD-006 Coil Only 1 25,050 [7.3] 8,750[2.6] 45,500[13.31 13.50 11.45 1200[566] 71 34,400[10.11 3 86 19,600 [5.7] 2.50 34,400[10.11 19,600[5.71 9.00 2 33,800 [9.9] 11,70013.4] 1475[696] 72 48,000[14.1] 30,400 [8.9] tp 1 31,900 [9.31 11,300[3.3] 1375[649] 76 44,500[13.0] 27,600 [8.1] 3.64 2.70 44,500[13.0] 27,600[8.1] 9.15 2 - 2 41,000[12.0] 17,000[5.0] 1675[790] 78 61,000[17.9] 40,500[11.91 CD RCSM-H"6024 iD RHPL-HM6024 58,000[17.0] 15.50 12.15 1-dehumid 29,450 18.6] 12,550[3.7] 1125[531] 76 a3 2-dehumid 37,850[11.1] 18,950[5.6] F1350[6371 78 RGFD 09?ZCM? 1 23,650 [6.9] 19,350[5.7] 57,000[16.7] 15.00 11.40 1150[5431 76 45,000[13.2] 3.56 27,800 [8.1] 2 66 45,000[13.2] 27,800[8.1] 9.55 2 40,350[11.8] 16,650[4.9] 1600[755] 78 61,500[18.0] 41,000[12.0] 1 23,550 [6.91 19,250[5.6] 1175[5541 76 45,000 113.21 27,800 [8.1] RGFD-10?ZCM? 56,500[16.6] 15.00 11.15 3.52 2.62 45,000[13.2] 27,800[8.1] 9.50 2 39,950[11.71 16,550[4.8] 162517671 78 61,500[18.01 41,500112.21 RGFD-12?RCM? 1 23,600 [6.91 19,400[5.7] 57,500[16.81 15.00 11.65 1225[578] 76 45,000[13.21 3.58 27,800 [8.11 2.68 45,000[13.21 27,800[8.1] 9.55 2 40,550[11.91 16,95015.0] 1650[779] 78 61,000[17.9] 1 41,000[12.0] 1 23,050 16.8] 18,750[5.5] 1200[566] 76 45,000[13.2] 27,800 [8.1] RGFE-09?ZCM? 56,500[16.6] 14.50 11.20 3.52 2.64 45,000[13.21 27,800[8.1] 9.50 2 39,950[11.7] 16,550[4.8] 1600[755] 78 61,500[18.0] 41,000[12.0] 1 23,100 16.8] 18,900[5.5] 1225[578] 76 45,000[13.2] 3.52 27,800 18.1] RGFE 10?ZCM? 2 39,850[11.7] 16,650[4.9] 56,500[16.6] 14.50 11.15 1600[755] 78 61,500[18.0] 41,500[12.2] 2.64 45,000[13.2] 27,800[8.1] 9.50 O60JEC 1 23,150- [6.8] 19,050[5.6] 1225[578] 76 44,500[13.0] 3.56 27,800 18.1] RGFE 12?RCM? 2 40,300[11.8] 16,700[4.9] 57,000[16.7] 14.50 11.40 1625[767] 78 61,500[18.0] 41,000[12.0] 2.66 44,500[13.0] 27,800[8.1] 9.55 RCFM-H'6024 1 23,650 [6.9] 19,350[5.7] 1175[554] 76 45,000[13.2] 27,800 [8.1] RGGD-09?ZCM7 57,000[16.7] 15.00 11.25 3.52 2.64 45,000[13.2] 27,800[8.1] 9.55 2 40,350[11.8] 16,650[4.9] 1675[790] 78 61,500[18.01 41,000[12.0] 1 23,650 [6.9] 19,350[5.7] 1175[554] 76 45,000 113.2] 27,800 [8.1] RGGD-10?ZCM? 57,000[16.7] 15.00 11.30 3.54 2.64 45,000[13.2] 27,800[8.11 9.55 2 40,400111.8] 16,600[4.9] 1625[7671 78 61,500 118.01 41,000[12.0] 1 23,650 [6.91 19,350[5.7] 1225[578] 76 44,500 113.01 27,800 [8.1]RGGD-12?RCM? 57,500[16.8] 15.00 11.55 3.56 2.68 44,500[13.0] 27,800[8.1] 9.55 2 40,700[11.91 16,800[4.9] 1650[779] 78 61,000[17.9] 41,000112.01 1 23,150 [6.8] 18,850[5.5] 1225[578] 76 45,000[13.21 27,800 [8.11 RGGE-09?ZCM? 2 40,350[11.8] 16,650[4.9] 57,000[16.71 14.50 11.40 1600[755] 78 61,500[18.0] 3.56 41,000[12.0] 2.66 45,000[13.2] 27,800[8.11 9.55 RGGE-10?ZCM? 1 23,050 16.8] 18,750[5.5] 56,500[16.6] 14.50 11.25 1200[566] 76 45,000[13.2] 3.54 27,800 [8.11 2.64 45,000[13.2] 27,800[8.11 9.50 2 40,000[11.7] 16,500[4.8] 16001755] 78 61,500[18.0] 41,000[12.01 RGGE-12?RCM? 1 23,150 [6.8] 19,050[5.6] 57,000[16.7] 15.00 11.65 1200[566] 76 44,500[13.0] 3.60 27,600 [8.1] 2.70 44,500[13.0] 27,600[8.11 9.60 2 40,300[11.8] 16,70014.9] 1575[743] 78 61,000[17.9] 40,500[11.9] O Highest sales volume tested combination required by DOE test procedures. [ ]Designates Metric Conversions Performance Data AHRI Standard Conditions (con't.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. AHRI Cooling Performance AHRI Heating Performance(70°F[21°C]Indoor) 80°126.5°Cl/67°F[19.5°Cl WB Indoor Air Outdoor Air Outdoor Air ' Model Numbers 95°F[35°C]DB Outdoor Air 47°F[8.5°C]r 17°F[-8.5°C]DB/ Outdoor 47°F[8.5°C]DB/ 17°F I-8.5°C]DB/ Unit Stage AHRI Ratings 43°F[6°Cl WB 15°F[-9.5°C]WB 43°F[6°C]WB 15°F[-9.5°CI WB DOE RPRL- Net Sensible Net Latent Indoor Airllaw Sound Region IV BTU/H[kW] BTU/H[kW] Total CFM[L/s] Rating HSPF ID Coil ID Air Mover Capacity SEER EER dB BTU/H[kW] COP BTU/H[kW] COP BTU/H[kW] BTU/H[kWl Rev. 1 23,650 [6.9] 19,350 15.7] 1175[554] 76 45,000 113.21 27,800 18.1] 2/24/2010 RGJD-09?ZCM? 2 40,350[11.8] 16,650[4.9] 57,000[16.7] 15.00 11.25 16751790] 78 61,500118.01 3.52 41,000[12.0] 2.64 45,000[13.2] 27,800 18.1] 9.55 1 23,650 16.9] 19,350[5.7] 1175[554] 76 45,000 113.2] 27,800 [8.1] RGJD-10?ZCM? 57,000[16.7] 15.00 11.30 3.54 2.64 45,000[13.2] 27,800[8.1] 9.55 2 40,400[11.8] 16,600[4.9] 1625[767] 78 61,500[18.0] 41,000[12.01 1 23,650 [6.9] 19,350[5.7] 1225[578] 76 44,500[13.01 27.800 [8.1] RGJD-12?RCM? 57,500[16.8] 15.00 11.55 3.56 2.68 44,500[13.01 27,800[8.1] 9.55 2 40,700-[11.9] 16,800[4.9] 1650[779] 78 61,000[17.9] 41,000[12.0] 1 23,150 [6.8] 18,850[5.5] 1225[578] 76 45,000[13.2] 27,800 [8.1] RGJF-09?ZCM7 2 40,350[11.8] 16,650[4.9] 57,000116.7] 14.50 11.40 1600[755] 78 61,500[18.0] 3.56 41,000[12.0] 2.66 45,000[13.2] 27,800[8.1] 9.55 1 23,050 [6.8] 18,750[5.5] 1200[566] 76 45,000[13.2] 3.54 27,800 [8.1] RGJF 10?ZCM? 2 40,000 111.71 16,500[4.8] 56,500[16.6] 14.50 11.25 1600[755] 78 61,500[18.0] 41,000[12.0] 2.64 45,000[13.2] 27,800[8.1] 9.50 RGJF-12?RCM? 1 23,150 [6.8] 19,050[5.6] 57,000[16.71 15.00 11.65 1200[566] 76 44,500[13.01 3.60 27,600 [8.1] 2.70 44,500[13.0] 27,600 18.11 9.60 2 40,300[11.81 16,70014.91 1575[743] 78 61,000[17.9] 40,500[11.9] 1 23,650 [6.9] 19,350 15.7] 122515781 76 44,500[13.0] 27,800 [8.1] RGLR-07?BRQ7 57,500[16.8] 15.00 11.70 3.60 2.70 44,500[13.0] 27,800[8.1] 9.60 2 40,600[11.9] 16,900[5.0] 1625[767] 78 61,000[17.91 41,000[12.01 RGLR-10?BRM7 1 23,700 [6.9] 19,300[5.7] 57,000[16.7] 15.00 11.7D 1200[566] 76 44,500[13.0] 3 62 27,600 [8.1] 2.70 44,500[13.0] 27,600 18.1] 9.60 2 40,350[11.8] 16,650[4.9] 1575[743] 78 61,000 117.91 40,500 111.91 RCFM-H*6024 RGLR-12?ARM? 1 23,700 [6.9] 19,500[5.7] 57,000[16.7] 15.00 11.80 1200[566] 76 44,500[13.0] 3.62 27,600 [8.11 2.72 44,500 113.01 27,600[8.1] 9.60 060JEC 2 40,300[11.8] 16,700[4.9] 1600[755] 78 61,000[17.9] 1 40,500 111.9] 1 23,700 [6.9] 19,300[5.7] 1225[578] 76 44,500[13.0] --27-,600-[8.1] RGPR-07?BRQ? 57,500[16.8] 15.00 11.75 3.62 2.70 44,500113.0] 27,600[8.1] 9.60 � 2 40,650[11.9] 16,850[4.9] 1625[767] 78 61,000[17.9] 40,500[11.9] 1 23,650 [6.9] 19,350[5.7] 12001566] 76 45,000[13.2] 27,800 [8.1] RGPR 10?BRM? 2 40,200[11.8] 16,800[4.9] 57,000[16.7] 15.00 11.55 1625[767] 78 61,000 117.9] 3.58 41,000[12.0] 2.68 45,000[13.2] 27,800[8.1] 9.55 2 1 23,650 [6.9] 19,350[5.7] 1250[590] 76 44,500[13.0] 27,800 [8.1] W RGPR-12?ARM? 57,000[16.7] 15.00 11.75 3.62 2,70 44,500[13.0] 27,800[8.1] 9.60 2 40,200[11.8] 16,800[4.9] 1575[743] 78 61,000[17.9] 40,500[11.9] co 1 23,500 [6.9] 19,100[5.6] 1225[578] 76 45,000[13.2] 28,000 [8.2] � RGRM-09?ZAJ? 56,500[16.6] 14.50 11.00 3.48 2.60 45,000[13.2] 28,000[8.2] 9.40 O 2 39,850[11.7] 16,650[4.9] 1 225[767] 78 62,000[18.2] 41,500[12.2] 1 23,550 [6.9] 19,250[5.6] 1150[543] 76 45,000[13.2] 28,000 18.21 :' RGRM-10?ZAJ? 2 39,950[11.7] 16,550[4.8] 56,500[16.6] 14.50 11.00 1600[755] 78 62,000[18.2] 3.48 41,500[12.2] 2.60 45,000[13.2] 28,000[8.2] 9.45 N a 1 23,550 [6.9] 19,25015.6] 1225[578] 76 45,000[13.2] 27,800 18.1] RGRM-12?RAJ? 2 40,250[11.8] 16,750[4.9] 57,000116.7] 15.00 11.40 1625[767] 78 61,500[18.0] 3.54 41,000[12.0] 2.66 45,000[13.2] 27,800[8.1] 9.50 RGTM-07?RBG? 1 23,350 [6.8] 19,050[5.6] 57,000116.7] 14.50 11.40 1325[625] 76 45,000[13.2] 3.54 28,000 [8.2] 2.64 45,000[13.2] 28,000[8.2] 9.45 = 2 40,250[11.81 16,750[4.9] 1675[790] 78 61,500[18.01 41,000[12.0] CD 1 23,300 [6.8] 19,100[5.6] 1275[602] 76 45,000[13.21 27,800 [8.1] RGTM-10?RBJ? 57,500116.8] 14.50 11.55 3.56 2.66 45,000113.21 27,800[8.1] 9.55 2 40,650111.9] 16,85014.91 1675[790] 78 61,000[17.91 41,000112.01 RCFM-H*6024+RXMD-CO6 Coil Only 1 30,900 [9.1] 11,300[3.3] 57,000[16.7] 14.00 11.45 1375[649] 76 45,500[13.3] 3.54 28,600 [8•4] 2.64 45,500[13.31 28,600[8.4] 9.20 2 40,000[11.7] 17,00015.01 1675[790] 78 61,500[18.01 41,000 112.01 w [ ]Designates Metric Conversions Electrical and Physical Data ELECTRICAL PHYSICAL Model Compressor Fan Motor Minimum Fuse or HACR Number Phase Outdoor Coil Retng• Weight Frequency(Hz) Rated Load Locked Rotor Full Load Circuit -Circuit Breaker Per RPRL _ Voltage(Volts) Amperes Amperes Amperes Ampacity Minimum Maximum. Face Area No. CFM[L/s] Circuit. Net Shipping (RLA) (LRA) (FLA) Amperes Amperes Amperes Sq.Ft [mz] Rows Oz.191 Lbs.[kg Lbs.[kgl Rev.2/24/2010 024JEC 1-60-208/230• 10.3/10.3 52 1.0 14/14 20/20 20/20 23 [2.14] 1 2300/2800 152 257 264 [1085/13211 [4309] [116.6] 1119.81 036JEC 1-60-208/230 16.7/16.7 82 1.7 23/23 30/30 35/35 22.2212.06] 2 / 245 311 315 [132/321/17746] [6946] [141.1] [142.9] 048JEC -1-60-208/230 21.2/21.2 96 2.0 29/29 40/40 45/45 22.22[2.06] 2 2800/3500 256 300 322 [1321/1652] [72581 [136.1] [146.1] 060JEC 1-60-208/230 25.6/25.6 118 2.2 35/35 45/45 50/50 22.22[2.061 2 3800 284 316 343, [1793] [80511 [143.31 [155.6] Unit Dimensions AIR DISCHARGE ALLOW 60"[1524 mm]CLEARANCE W L ACCESS PANEL H 0 AIR INLETS ALLOW 24"[610 mm] (LOUVERS) ACCESS CLEARANCE ALLOW 12"1305 mm] LOW VOLTAGE MIN.CLEARANCE CONNECTION 3 SIDES o Ve"[22 mm] SERVICE FITTINGS ' Model Number Height"H" Length"L" Width"W" RPRL- (Inches)[mm] (Inches)[mm] (inches) [mml 024JEC/036JEC/ HIGH VOLTAGE . 048JEC/060JEC . 33[838] 443/8[1127] 311/2[800] o CONNECTION ® 111/32"[34 mm] o ® 0 [ ]Designates Metric Conversions o ® LIQUID LINE o CONNECTION SERVICE ACCESS VAPOR LINE TO ELECTRICAL& CONNECTION 211e[73 mm]DIA. VALVES ALLOW ACCESSORY 24"[610 mm] KNOCKOUTS CLEARANCE HIGH PRESSURE CONTROL ONE SIDE MANUAL RESET (FIELD INSTALLED ACCESSORY). 14 Rheem Heating, Cooling and Water Heating Heat Pump Refrigerant Line Size Information Liquid Line Size R 410A Line Size. Outdoor Unit Above or eat Pump Only)Indoor Coil System Connection Line Size Capacity Size (inch O.D.) Total Equivalent Length-Feet[m] Model (Inch I.D.) [mm] 25 50 75 100 125 150 [mm] [7.62] [15.241 [22.861 [30.48] [38,10] [45.721 Maximum Vertical Separation-Feet[m] 1/4" [6.351* 25[7.62] N/A N/A N/A N/A N/A [99.5.53] 5/16 [7.93] 25[7.62] 36[ -024 " 10.97] 33[10.06] 28 [8.53] 22 16.71] 16 [4.881 3/8" [9.52] 25[7.62] 41 [12.50] 40[12.19] 39[11.89] 37[11.281 36[10.97] 5/16" [7.93]* 25[7.62] 22 [6.71] 9 [2.74] N/A N/A N/A -036 3/8[9.53] 3/8" 19.521 2517.621 39111.89] 34[10.36] 30 [9.14] 25 [7.62] 21 [6.40] 1/2"[12.70] 25[7.62] 46[14.02] 45[13.72] 44[13.41] 43[13.11] 42[12.80] 5/16" [7.931* 25[7.621 17 [5.18] N/A N/A N/A N/A -048 3/8[9.53] 3/8" [9.52] 2517.621 47[14.33] 39[11.89] 31 [9.45] 23 [7.01] 16 [4.88] 1/2"[12.70] 25[7.62] 50[15.24] 58[17.68] 56[17.07] 54[16.46] 53[16.151 -060 3/81' 3/8" [9.52]* 25[7.62] 18 [5.49] 11 [3.35] N/A N/A N/A [9.53] 1/2"[12.70] 25[7.62] 29 [8.84] 27 [8.23] 26 [7.93] 25 [7.62] 23 [7.01] NOTES:N/A=Application not recommended. *Standard line size. SUCTION LINE SIZE-OUTDOOR UNIT ABOVE INDOOR COIL R-410A Suction Line Size System Line Size Line Size Outdoor Unit ABOVE Indoor Coil(Heat Pumps) Capacity Connection Size (Inch O.D.) Total Equivalent Length-Feet[m] Model (Inch I.D.)[mm] [mm] 25[7.62] 1 50[15.24] 1 75[22.86] 1 100[30.481 125[45.721 150[45.721 5/8"[15.88] Same as Liquid Line Size Table -024 3/4[19.05] 3/4"[19.05]* NA 7/8"[22.23] NA 5/8"[15.88] Same as Liquid Line Size Table -036 3/4 3/4"[19.05]* NA [19.05] 7/8"[22.23] NA 5/8"[15.88] Same as Liquid Line Size Table -048 7/s 3/4"[19.05] Same as Liquid Line Size Table [22.22] 7/8"[22.23]* Same as Liquid Line Size Table 3/4"[19.05] Same as Liquid Line Size Table -060 7/8 7/8"[22.23]* Same as Liquid Line Size Table [22.22] 1-1/8"(28.581 NA NOTES:Using suction line larger than shown in chart will result in poor oil return and is not recommended.N/A=Application not recommended. *Standard line size. SUCTION LINE SIZE-OUTDOOR UNIT BELOW INDOOR COIL R-410A Suction Line Size System Line Size Line Size Outdoor Unit BELOW Indoor Coil(Heat Pumps) Capacity Connection Size (Inch O.D.) Total Equivalent Length-Feet[m] Model (Inch I.D.)[mm] [mm] q 9 25[7.621 1 50[15.24] 1 75[22.86] 1 100[30.48] 1 125145.721 1 150[45.721 5/8"[15.88] Same as Liquid Line Size Table -024 3/4 3/4"[19.05]* Same as Liquid Line Size Table N/A [19.05] 7/8"[22.231 N/A 5/8"[15.881 Same as Liquid Line Size Table -030 3/4" 3/4"[19.051* Same as Liquid Line Size Table [19.05] 7/8"[22.23] N/A 5/8"[15.88] Same as Liquid Line Size Table -048 7/8 3/4"[19.05] Same as Liquid Line Size Table [22.231 7/8"[22.23]* Same as Liquid Line Size Table 3/4"[19.05] Same as Liquid Line Size Table -060 7/8 7/8"[22.23]* Same as Liquid Line Size Table [22 23] 1 1/8"[28.581 Same as Liquid Line Size Table NOTES:Using suction line larger than shown in chart will result in poor oil return and is not recommended.N/A=Application not recommended. *Standard line size. [ ]Designates Metric Conversions Rheem Heating, Cooling and Water Heating 15 Vapor Line Capacity Multiplier . (-)PRL- 024 036 048 060 Unit Vapor Line 3/4"[19.051 7/8"[22.231 7/8"[22.231 7/8"[22.231 Connection Size(Inches I.D.)[mml I.D.Sweat I.D.Sweat I.D.Sweat I.D.Sweat Vapor Line Diameter(inches O.D.)[mm] 5/8"[15.881 5/8"[15.88] 5/8"[15.881 3/4"[19.05] Optional Optional Optional Optional Vapor Line Run Feet[m] 3/4"[19.051 3/4"[19.05] 3/4"[19.051 7/8"[22.231 Standard Standard Standard Standard 7/8"[22.231 11/8".[28.581 Optional Optional Optional 1.00 0.99 0.98 0.99 . 25' [7.62] Standard 1.00 1.00 1.00 1.00 Optional N/A N/A 1.01 1.01 Optional 0.99 0.98 0.96 0.98 50'(15.241 Standard. 1.00 1.00 0.99 1.00 Optional N/A N/A 1.00 1.00 Optional 0.98 0.96 0.93 0.97 75'[22.861 Standard 1.00 0.99 0.98 0.99 Optional N/A N/A 1.00 1.01 Optional 0.97 0.95 0.92 0.96 100'[30.481 Standard N/A N/A 0.97 0.98 Optional N/A N/A N/A N/A Optional 0.97 0.94 0.90 0.95 125'[38.10] Standard N/A N/A 0.97 0.98 Optional N/A N/A N/A N/A Optional 0.96 0.93 0.88 0.93 150'[45.72] Standard N/A N/A 0.96 0.98 Optional N/A N/A N/A N/A NOTES: 1.Do NOT exceed the limits in the liquid and suction line sizing charts. 2.Do NOT use 7/8 OD suction lines in 2 or 3-ton applications. 3.1-1/8 OD suction line approved for 5-ton applications only but has length restrictions.Reference the liquid and suction line sizing charts. [ ]Designates Metric Conversions GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product Limited Parts Warranty: which fails in normal use and service within the applicable Rheem Prestige SeriesTm equipment features.a 1 O-year lim-. period stated,in accordance with the terms of the limited ited parts warranty.* warranty. *This ten-year limited parts warranty is applicable only to single-phase For Complete Details of the Limited Warranty,Including Applicable Terms products installed in residential applications. and Conditions,See Your Local Installer or Contact the Manufacturer for RPRL-JEC Conditional Replacement Warranty: a.Copy. Rheem will provide a replacement RPRL-JEC Heat Pump to the original purchaser if the compressor fails within 10 years (providing the unit is installed with a new R[ieem Air Handler OR Rheem Indoor Coil with a Rheem Gas Furnace,and is properly matched according to Rheem specifications),and if additional conditions are satisfied.See product warranty card for additional information. Before proceeding with installation,refer Rheem Heating, to installation instructions packaged Cooling and ' with each model,as well as complying Water Heating t with all Federal,State,Provincial,and Local codes,regulations,and practices. P.O.Box 17010,Fort Smith,AR 72917 `7n keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice." PRINTED IN U.S.A. 4-10 DC FORM NO..P11-778 REV.2 I Supersedes Form No.P11-778 Rev..1