Loading...
HomeMy WebLinkAbout49546-Z ¢�o�og�EFO(��OG Town of Southold 11/16/2023 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44731 Date: 11/16/2023 THIS CERTIFIES that the building ALTERATION Location of Property: 1400 Silvermere Rd,Greenport Greenport SCTM#: 473889 Sec/Block/Lot: 47.-2-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/9/2023 pursuant to which Building Permit No. 49546 dated 8/4/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations(diner and bar areas for motel guests only)to existing motel building as applied for. The certificate is issued to Silver Sands Hldgs I LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL C-23-0169 7/19/2023 ELECTRICAL CERTIFICATE NO. 49546 10/13/2023 PLUMBERS CERTIFICATION DATED 6/5/2023 17PiRV,,reaIMPlumbing Aut oriz d i ature ' TOWN OF SOUTHOLD ��o�SUff01K�oGy BUILDING DEPARTMENT a TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49546 Date: 8/4/2023 Permission is hereby granted to: Silver Sands Hldgs I LLC c/o Alexander Perros 19215 Soundview Ave Southold, NY 11971 To: construct alterations (diner and bar areas for motel guests only) to existing motel building as applied for per SCHD approvals. Installation of Type one kitche ood system ns��lation Ansul°s�stem�<. `�/p f23 `i At premises located at: 1400 Silvermere Rd, Greenport SCTM # 473889 Sec/Block/Lot#47.-2-11 Pursuant to application dated 6/9/2023 and approved by the Building Inspector. To expire on 2/2/2025. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $546.40 CO-COMMERCIAL $50.00 FIRE SUPP. SYSTEM/HOOD/EXHAUST SYSTEM $250.00 ELECTRIC $125.00 FIRE SUPP. SYSTEM/HOOD/EXHAUST SYSTEM $250.00 Total: $1,221.40 Building Inspector - I �SUFf TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY 4,1 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 49546 Date: 8/4/2023 Permission is hereby granted to: Silver Sands Hldgs I LLC c/o Alexander Perros 19215 Soundview Ave Southold, NY 11971 To: construct alterations (diner and bar areas for motel guests only) to existing motel building as applied for per SCHD approvals. f'Unstallation of Type one kitchen hood system At premises located at: 1400 Silvermere Rd, Greenport SCTM # 473889 Sec/Block/Lot# 47.-2-11 Pursuant to application dated 6/9/2023 and approved by the Building Inspector. To expire on 2/2/2025. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $546.40 CO-COMMERCIAL $50.00 FIRE SUPP. SYSTEM/HOOD/EXHAUST SYSTEM $250.00 Total: $846.40 vj Building Inspector TOWN OF SOUTHOLD �o�guFFO(K`o BUILDING DEPARTMENT TOWN CLERKS OFFICE Wo +� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49546 Date: 8/4/2023 Permission is hereby granted to: Silver Sands Hldgs I LLC c/o Alexander Perros 19215 Soundview Ave Southold, NY 11971 To: construct alterations (diner and bar areas for motel guests only) to existing motel building as applied for per SCHD approvals. At premises located at: 1400 Silvermere Rd, Greenport SCTM #473889 Sec/Block/Lot#47.-2-11 Pursuant to application dated 6/9/2023 and approved by the Building Inspector. To expire on 2/2/2025. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $546.40 CO-COMMERCIAL $50.00 Total: $596.40 Building Inspector pf SOUT��! Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(-town.southold.ny.us Southold,NY 11971-0959 Q`�COU�'�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Silver Sands Holdings I LLC Address: 1400 Silvermere Rd city:Greenport st: NY zip: 11944 Building Permit#: 49546 Section: . 47'Block: 2 Lot: ' 11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Wilcenski Electric License No: SITE DETAILS Office Use Only Residential Indoor X Basement Service X Commerical X Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 13 Ceiling Fixtures 8 Bath Exhaust Fan 1 Service 3 ph X Hot Water GFCI Recpt 9 Wall Fixtures 4 Smoke Detectors Main Panel 225A A/C Condenser 1 Single Recpt Recessed Fixtures 13 CO2 Detectors 2 Sub Panel 100X2 A/C Blower 1 Range Recpt Gas Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights 14' Dryer Recpt Emergency Strobe 1 Heat Detectors 1 Disconnect Switches 12 4'LED Exit Fixtures 2 Sump Pump Other Equipment: Heat Lamps(2), Cooktop, Hood, Oven, Fridge, Mini Fridge(2), DW(2), 225A Panel 42 Circuit/40 Used, 100A Sub 24 Circuit/ 23 Used, 100A Sub 24 Circuit/ 22 Used Notes: Diner Inspector Signature: Date: October 13, 2023 S.Devlin-Cert Electrical Compliance Form o Town Hall Annex Telephone(631)765-1902 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD SEP Building Departrnent Town of Southold CERTIFICATION Date: Building Permit No. Owner: (Please print) Plumber: ) 10t�-- D4'—C—"AeAS (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (Plumbers Signatures Sworn to before me this day of 201Z) PAUL C CAPERNA NOTARY PUBLIC,STATE OF NEW YORK Registration No. County51160 oun Qualified in Suffolk County County Commission Expires August 1d Ar, Notary Public, slk?...d _Cuunly w J \i laf so TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] RO GH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTI [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUG [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATI [ ] PRE C/O [ ] RENTAL REMARKS: 64 i r ✓lL G4G CS/ '(lv� . • kww� DATE �/ 'Y INSPECTOR Y661 5, 1-es 0f SOUlyO� I(v 5PI21 5- f TOWN OF SOUTHOLD BUILDING DEPT. `ycou 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING 11QFINAL J [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION/ [ ] PRE C/O [ ] RENTAL REMARKS: �'.���" � DATE �/ INSPECTOR �aOF SOUTyo 1...� Lq vV V l IV cr,41 of e -- # # TOWN OF SOUTHOLD BUILDING DEPT. `yCom 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE &-CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: g/ �c Ii✓fro J� I a-1 12/0!el eAcJ_ C'tb ' �1 0 JIQ LIA o� n AA4, V�- P oA � C� &4i-� ov DATE INSPECTOR v o��0f SOUIyo # # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING FINAL P 51) / qOd [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 1& 0� lg 1 t- -7� Al wktm/ DATE f INSPECTOR hO��OF SOUIyo� / # TOWN OF SOUTHOLD BUILDING DEPT. °`ycourmN�'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING jk FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: M/ � &le le, U wwL.el DATE �� Z3 INSPECTOR ►—r�'1 (/l s�� pE SOGjy�� �/�, f # TOWN OF SOUTHOLD BUILDING DEW. couKn, ' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) °r7 ELECTRICAL (FINAL) [ ] CODE VIOLATION /[ ] PRE C/O [ ] RENTAL REMARKS: DATE LQ I INSPECTOR Food Establishment Inspe Page 1 of 3 Suffolk County Department of Health Services 360 Yaphank Avenue Suite 2A Yaphank,NY 11980 Date: 10/10/2023 631-852-5999 �d OCT 2023 www.suffolkcountyny.gov/health Il Establishment Name Establishment Address City/ ,nc 6�e a = `' Zip Code Telephone SILVER SANDS DINER 1400 SILVERMERE RD GREL�fj Y ��;' :�M '' 11944 Permit ID# Permit Holder Purpose of Inspection Result of Inspection FSP-23-0012225 DHG SILVERSANDS LLC Obs Premise/Facility Inspection Permit Issued Owner Owner Address Permit Restrictions Capacity DHG SILVERSANDS LLC 160 MERCER STREET,STE.2,NEW YORK NY 10012 seats INSPECTION VIOLATIONS Comply by Date Degree of Violation:RISK FACTOR 10-REQUIRED RECORDS AVAILABLE-SHELLFISH TAGS, PARASITE DESTRUCTION 10/10/2023 Code Section(s)/Local Law(s): 760-1318.4-Shellstock tags shall remain attached to the container in which the shellstock are received until the container is empty. (a)The identity of the source of shellstock that are sold or served shall be maintained by retaining shellstock tags or labels for 90 calendar days from the date the container is emptied by:(1) Using an approved record-keeping system that keeps the tags or labels in chronological order correlated to the date when,or dates during which,the shellstock are sold or served';and (2) If shellstock are removed from their tagged or labeled container: (a) Preserving source identification by using a record keeping system as specified under Subsection 4.a.(1)above and (b) Ensuring that shellstock from one tagged or labeled container are not commingled with shellstock from another container before being ordered by the consumer. Violation Description(s): SHELLFISH TAGS FOR RAW OYSTERS STORED IN THE REACH IN REFRIGERATOR IN THE PREP ROOM OF THE BOATHOUSE WERE NOT ATTACHED TO THE CONTAINER IN WHICH THE OYSTERS WERE STORED. --CORRECTIVE ACTION:ATTACHED Degree of Violation:RISK FACTOR 12-FOOD CONTACT SURFACES-CLEANED AND SANITIZED 10/10/2023 Code Section(s)/Local Law(s): 760-1346.3.a-Kitchenware and food contact surfaces of equipment, including food temperature measuring devices, exclusive of cooking surfaces of equipment, used in the preparation or serving of food or drinks and all food storage utensils, shall be thoroughly cleaned and sanitized after each use, and following any interruption of operations during which contamination of the food contact surfaces is likely to have occurred. Violation Description(s): THE DEFLECTOR INSIDE THE SHAVED ICE MACHINE WAS NOTED WITH ACCUMULATED BLACK GRIME. --CORRECTIVE ACTION:CLEAN IMMEDIATELY Degree of Violation:GOOD RETAIL PRACTICE 41 -UTENSILS, EQUIPMENT AND LINENS 10/24/2023 Code Section(s)/L.ocal Law(s): 760-1346.14.j.3-Utensils and equipment shall be stored above the floor in a clean,,dry location. Suitable space and facilities shall be provided for such storage so that food contact surfaces are protected from splash, dust, and other contamination. Food equipment and utensils shall not be stored or located under waste or sewer lines or non-potable water lines. Violation Description(s): ICE SCOOPS WERE STORED ON TOP OF THE SHAVED ICE MACHINE AND ICE MACHINE SO THAT FOOD CONTACT SURFACES WERE SUBJECTED TO CONTAMINATION. Degree of Violation:GOOD RETAIL PRACTICE 47-TOILET FACILITIES-PROPERLY CONSTRUCTED,SUPPLIED AND MAINTAINED 10/24/2023 Code Section(s)/Local Law(s): 760-1353.1.c-Toilet rooms shall be completely enclosed and shall.have tight fitting, self-closing doors. 5002 Food;Establishment Inspection Report Suffolk County Department of Health Services ._ w 4;f •' , Page 2 of 3 360 Yaphank Avenue Suite 2A Yaphank,NY 11980 Date: 10/10/2023 631-852-5999 ` www.suffolkcountyny.gov/health Establishment Name Establishment Address City/State Zip Code Telephone SILVER SANDS DINER 1400 SILVERMERE RD GREENPORT, NY 11944 Permit ID# Permit Holder Purpose of Inspection Result of Inspection FSP-23-0012225 DHG SILVERSANDS LLC Obs Premise/Facility Inspection Permit Issued Owner Owner Address Permit Restrictions Capacity DHG SILVERSANDS LLC 160 MERCER STREET,STE.2,NEW YORK NY 10012 seats INSPECTION VIOLATIONS `Comply by Date Violation Description(s): THE LOBBY BAR UNISEX TOILET ROOM DOOR WAS NOT SELF-CLOSING. THE DINER UNISEX TOILET ROOM DOOR WAS NOT SELF-CLOSING. Overall Inspection Comments: RE:Permit Issuance Ok to Issue Permit for the following areas of the establishment;The Diner,the Lobby Bar,the two exterior walk-in refrigerators and prep area in the boathouse service kitchen.The bar area of the boathouse service kitchen and the seasonal oyster bar kiosk were not ready at the time of inspection.According to operator these areas will be ready for Pre-Operation inspection within the next couple of weeks. Operator instructed to schedule a Pre-Operational inspection upon completion of renovations to both the boathouse service kitchen bar area and oyster bar kiosk. Inspected By Michael Cromwell, San ID#963 Cooper Min/Max 963 used Risk Factors cited in consecutive inspections may result in enforcement action, including a possible hearing and fine. THE FOOD MANAGER'S COURSE IS AVAILABLE ONLINE IN ENGLISH, SPANISH AND CHINESE! To register for the Food Manager's course, please visit https://apps2.suffolkcountyny.gov/Health/FdOnline/default.aspx. Suffolk County FMC App and SIRF self-inspection app for mobile devices are available for download from Google Play and the Apple Store. All food service establishment operators are required to post the following advisory on all menus(including website menus)and menu boards located inside or outside of the establishment:"Before placing your order, please inform your server if a person in your parry has a food allergy".College, public and private school food operations are exempt. Effective Jan. 1,2020 all drinking straws and stirrers must be provided in food establishments by consumer request only, and must be made of biodegradeable(non-plastic) material. Plastic drinking straws and stirrers may continue to be provided by request to consumers with a disability or medical condition. Effective July 1, 2021 the use of latex products is prohibited in all food establishments. Further information at https://suffo I kco u ntyny.gov/Departments/Health-Services/P ub I is-H ealth-P rotectio n/P lastics-and-Latex-Laws Suffolk County Local Law 29-2009 amended Chapter 437(now Chapter 754)of the Suffolk County Code to prohibit"heating or ignition of an e-cigarette which creates a vapor"in all public places.The use of"E-CIGARETTES" IN ALL ESTABLISHMENTS WITH A SUFFOLK COUNTY FOOD PERMIT IS PROHIBITED, SUBJECT TO ALL PROVISIONS OF THE NY STATE CLEAN INDOOR AIR ACT AND SUFFOLK COUNTY LOCAL LAW. EMPLOYEE SICK POLICY WAS DISCUSSED DURING THE INSPECTION: Person in charge was reminded that all sick employees MUST be excluded from food service. No sick employee is permitted to return to work until they have been symptom-free for at least 24 hours;certain illnesses require that employees are tested prior to returning to work, even if symptom-free, or require further Department approval. Contact the Bureau of Public Health Protection for details. A log must be kept on-site documenting the exclusion of ill employees. 5002 Food Establishment Inspection Report Suffolk County Department of Health Services Page 3 of 3 360 Yaphank Avenue Suite 2A Yaphank,NY 11980 Date: 10/10/2023 631-852-5999 www.suffolkcountyny.gov/health Establishment Name Establishment Address City/State Zip Code Telephone SILVER SANDS DINER 1400 SILVERMERE RD GREENPORT,NY 11944 Permit ID# Permit Holder Purpose of Inspection Result of Inspection FSP-23-0012225 DHG SILVERSANDS LLC Obs Premise/Facility Inspection Permit Issued Owner Owner Address Permit Restrictions Capacity DHG SILVERSANDS LLC 160 MERCER STREET,STE.2,NEW YORK NY 10012 seats .Signatures V Michael Cromwell Person Receiving Report "The items noted above are violations of applicable laws,rules and regulations found during an inspection of the operation of the facilities in this establishment which must be corrected as indicated. Failure to comply may result in the initiation of legal action against this establishment as provided for in Articles 2 and 13 of the Suffolk County Sanitary Code including a hearing,possible suspension of your food operation,and/or the publication of the violation and fines." STEVEN BELLCNE ,�r:G GREGSON H.PIGOTT,MD,MPH SUFFOLK COUNTY EXECUTIVE +C9k COMMISSIONER SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES D E V E L'! E 1 0 CT 3 1 2023 BWKnq Dep-r-21-m-mt 5002 N. J. MAZZAFERRRO, P.E. PO Box 57,Greenport,N.Y. 11944 Phone- 516-457-5596 Consulting Engineer September 5,2023 Design, Construction, Inspection Page 1 of 1 Town of Southold-Building Department 53095 Main Road Southold NY 11971 V n Re: Silver Sands Holdings, LLC 2 ' —} 1400 Silvermere Road S E P 1 4 2023 Greenport,N.Y. 11944 I,MDING DEPT. District-1000, Section-47,Block-2,Lot-11 (Main Motel) ' P Building Permit Number—49546—Main Bldg. —Diner Area Inspection—Rough Plumbing On September 5, 2023, I inspected the construction for the alterations at the noted location. The inspection covered the interior plumbing for the Drainage Waste and Vent System(DWV)and the Water Supply System(WS). The inspection results are: 1 —DWV—System was readily viewed. I observed the drainage and vent lines. System constructed as required.New installation is connected to the existing sewer system.All construction was done in compliance with the applicable sections of the IRC,NYS and Town of Southold Building Codes. 2—WS—System was readily viewed. I observed the hot and cold water supply lines. System constructed as required. All construction was done in compliance with the applicable sections of the IRC,NYS and Town of Southold Building Codes. Note—The rough plumbing was connected to the existing water and septic systems which are part of the Village of Greenport master system Result—Based upon inspection of this project and to the best of my knowledge,belief and professional judgment, construction as installed complies with the plans and applicable codes of the IRC,NYS and Southold Town Building Codes. 9 Nicholas J.Mazzaferro,P.E. j o ' w y�Fp 40 A�opzsslotA�" FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION 1ST ------------------------------------ FOUNDATION (2ND) a- z s o . O� ROUGH FRAMING& a PLUMBING �) 1 INSULATION PER N.Y. STATE ENERGY CODE 3 Wood, t ok okr FINAL ADDITIONAL COMMENTS co IN o ti. Q Q rem SithA d e � O I C�J � H r x ae �I �y i TOWN OF SOUTHOLD—BUILDING DEPARTMENT C.?I53) Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 76571802 Fax(631) 765-9502 https://www.southoldtowiwy.puv Date Recei d APPLICATION FOR BUILDING PERMIT r_: For Office Use Only PERMIT NO. Building Inspector: "� JUN — 9 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an •TI,T - ••[ Owner's Authorization form(Page 2)shall be completed. ?" Date:JUNE 8, 2023 OWNER(S)OF PROPERTY: Name:SILVER SANDS HOLDINGS I, LLC SCTM#1000-47-2-11 Project Address:1400 SILV_ERMER_E_ ROAD GREENPORT NY 11944 Phone#:917-318-0027 _ _ Email:A_L_E_X@SILVERSANDS�MOTEL.COM Mailing Address:1400 SILV_ERME_ RE_ ROAD, GREEN PORT, NY 11944 _ CONTACT PERSON: Name:ALEXANDER PE_R_R_OS Mailing Address:19215 SOUNDVIEW AVENUE,. SOUTHOLD, NY 11971 Phone#:917-318-0027 _ _ Email:AL_EX_@SILVERSANDSMOTEL.COM DESIGN PROFESSIONAL INFORMATION: Y Name:JOHN CONDON PE. - CONDON ENGINEERING Mailing Address:1755 SIGSBEE ROAD MATTITUCK NY,11952 Phone#:631-298-1896 Email:condoneng@optoniine.net CONTRACTOR INFORMATION: Name:Chenal & Tzun Construction LLC Mailing Address:950 Silvermere Road, Green_port,,_NY 11944 Phone#:(631) 599-2620 ___ _ _ Email:Waltertzun@hotmail.com DESCRIPTION OF PROPOSED CONSTRUCTION T ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: D Other Install kitchen equipment in old diner space and add bar to lobby INCLUDED IN PREVIOUSLY SUPPLIED BUDGETS Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premi ies? ❑Yes ®No 1 I I PROPERTY INFORMATION Existing use of property:MOTEL_ Intended use of property:MOTEL Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to RR this property? Dyes ®No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class,A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Alexander Perros ❑Authorized Agent BOwner Signature of Applicant: �4 4 _ Date_June 8, 2023 STATE OF NEW YORK) 1 1 SS: CONNIE D.BUNCH COUNTY OF SUFFOLK Notary Public,State of New York No.01 BU6185060 Qualified in Suffolk County y being dul 4 IsVg600e�'an�says t at a is the applicant (Name of individual signing contract)above named, (S)he is the OWNER (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ' `'l 20 a �C171 l r"p /�44(/` Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I. residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name '1 1, 2 1 1 1 I ��gUfFOLK�oGy TOWN OF SOUTHOLD—FIRE MARSHAL Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov f FIRE PROTECTION SYSTEM PERMIT Date Received APPLICATION r Office Use Only E (� E PERMIT NO. Building Inspector: �7 MAR 2 8 2023 Applications and forms must be filled out in their entirety.Incomplete rl =1 applications will not be accepted.WORK IS NOT TO BE STARTED prior to the approval of plans and issuance of a permit. 7OWN OFS0t)TH&D Hasa building permit been obtained for this project?Iftes []No If yes,building permit# ' Ll 8 06 Date: 3 -a PROJECT INORMATION: Project Address: I LI w Si I v•ecz.m eQ.e fZ d SCTM# 10000�-/L j' —a --1 I City: G ue;CA) Poe+ zip: / 19�7`t CONTACT PERSON INFORMA ION: Name: Mailing Address: 7a C pa-G Sf Hd[b awf Phone#: 3(_g7g_� � Email: �b�- i�� QhC�•C1 Preferred contact method(select one): []Phone `4Email CONTRACTOR INFORMATION: Name: Contractor License#:R�T o esl + Fire (�o`�I (��-con- 11 I Mailing Address:1-3a4 ChU.¢Ch .S T4 O (LOQ - Phone#:�I_g� .-yg90 Email:- i Q.e a h op. C Onn SCOPE OF WORK: Occupancy Description: ❑Assembly K.Business EI Education ❑Factory/Industrial ❑Institutional ❑Mercantile ❑Residential ❑ Storage Description of Work: .j nSCACAkOn O -__ CO mmf(LC16 L4ChfAI ha Nead S ,* New System ❑ Existing System Modification Sprinkler/Standpipe/.Water Supply Fire Alarm/CO Detection Systems Other Fire Protection Systems (Check all that apply) (Check all that apply) (Check all that apply) ❑NFPA 13,13D or 13R System ❑Manual ❑Automatic ❑ Smoke Control ❑Standpipe ❑Fire Pump [--]Protected Premises (local) ❑ Wet or Dry Chemical/Clean ❑Supervising station Agent Number of sprinkler heads: ❑Central Station Kitchen hood/exhaust ❑ Other Floor Area(sq. ft.): - 1 eCheck Box After Reading: I,the undersigned,understand that the issuance of a permit for the type which is herein applied for is based on .he agreement to conform to all regulations and requirements.I further understand that non-compliance of said requirements,by myself or any officer or employee of the firm or individual listed as the applicant on this form,shall be cause for revocation of said permit.Upon revocation of said permit the applicant or any employee of the applicant shall be prohibited to conduct such work for which this permit was issued.The reissuance of a permit shall be based upon review of the circumstances leading to the revocation.Any false statement(s)made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the Penal Law Application Submitted By(print name): Dmt Authorized Agent []Owner Company(if applicable): OCSI�AJ 4-1961 r 2lf Applicant'Signature: [Date: —3 aCf O13 FIRE PROTECTION SYSTEM PERMIT PPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE ALARM/CARBON MONOXIDE DETECTION SYSTEM SUBMITTAL GUIDELINES • FIRE SPRINKLER SYSTEM SUBMITTAL GUIDELINES • FIXED FIRE SUPPRESSION,HOOD&EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$250 permit fee is required for a non-residential permit.A$50 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town.of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testing/inspection shall be made by contacting the Town of Southold Building Department(631)765-1802. ILI ' MAR 2 8 2023 TOWN OFSOMPOLD FOR OFFICE USE ONLY Amount Paid: Check No.: FM: Permit No.: Date: Exp.Date: 2 i TOWN OF SOUTHOLD—FIRE MARSHAL y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov FIRE PROTECTION SYSTEM PERMIT Date Received APPLICATION For Office Use Only py PERMIT NO. w Building Inspector: Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted.WORK IS NOT TO BE STARTED prior MAR 2 2 2023 to the approval'of plans and issuance of a permit. Hasa building permit been obtained for this project? ❑Yes ❑No W1Y0FS()Y17 -8dLII3 If yes,building permit# Date: PROJECT_INORMATION: Project Address:1400Silvermere Road SCTM#1000= city:Greenport NY zip:11944 CONTACT PERSON INFORMATION: Name:David DeMarco Mailing Address:75 Calvert Street Harrison NY 10528 Phone#:914 584 6469 Email:ddemarco@interstatefireandsfty.,net Preferred contact method(select one): ❑Phone DEmail CONTRACTOR INFORMATION: Name:Interstate Fire & Safety Contractor License#: Mailing Address:75 Calvert Street Harrison NY 10528 Phone#:914 937 6100 Email:ddemarco@interstatefireandsfty.-net SCOPE OF WORK: Occupancy Description: R Assembly ❑Business ❑ Education ❑Factory%Industrial ❑Institutional ❑Mercantile ❑Residential ❑ Storage Description of`'Fork:Installation of fixed wet chemical fire' suppression for cooking media 8 New System ❑ Existing System Modification Sprinkler/Standpipe/Water Supply Fire Alarm/CO Detection Systems Other Fire Protection Systems (Check all that apply) (Check all that apply) (Check all that apply) ❑NFPA 13,13D or 13R System ❑Manual ❑Automatic ❑ Smoke Control ❑Standpipe ❑ Fire Pump ❑Protected Premises (local) 9 Wet or Dry Chemical/Clean El Supervising station Agent . Number of sprinkler heads: ❑Central Station ❑ Kitchen hood/exhaust ❑ Other Floor Area(sq. ft.): 1 ❑ Check Box After Reading: I,the undersigned,understand that the issuance of a permit for the type which is herein applied for is based on the agreement to conform to all regulations and requirements.I further understand that non-compliance of said requirements,by myself or any officer or employee of the firm or individual listed as the applicant on this form,shall be cause for revocation of said permit.Upon revocation of said permit the applicant or any employee of the applicant shall be prohibited to conduct such work for which this permit was issued.The reissuance of a permit shall be based upon review of the circumstances leading to the revocation.Any false statement(s)made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the Penal Law Application Submitted By(print name): David DeMarco DAuthorized Agent ❑Owner Company(if applicable): Interstate Fire & Safety Applicant Signature: 4- W -- Date: 3/21/2023 FIRE PROTECTION SYSTEM PERMIT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE ALARM/CARBON MONOXIDE DETECTION SYSTEM SUBMITTAL GUIDELINES • FIRE SPRINKLER SYSTEM SUBMITTAL GUIDELINES • FIXED FIRE SUPPRESSION, HOOD&EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$250 permit fee is required for a non-residential permit. A$50 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testing/inspection shall be made by contacting the Town of Southold Building Department(631)765-1802. FOR OFFICE USE ONLY Amount Paid: Check No.: FM: Permit No.: Date: Exp.Date: 2 g1�EFptk BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD y- = Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765.9502 rogerr(cD-southoldtownny.gov — seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance r Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: -- Address: DD eA. 11/�Y Cross Street: Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: Block: Lot: BRIEF ESCRIPTIO,� O�F WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In 0 Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect Flood Reconnect❑Service,Reconnect❑Underground❑Overhead # Underground Laterals 1 FJ2 H Frame Pole Work done on Service?' Y N Additional Information: PAYMENT DUE WITH APPLICATION Yes PERMIT 9 Address: Switches Outlets GFI's , Surface — II` Sconces I �I 1 H H's Wi. III /z � UC Lts Fans Fridge I HW Exhaust l Oven W/D Smokes 'DW Mini 1 Carbon Micro Generator r %r 1 -ombo Cooktop Transfer aC AH Hood Service nAmps Have Usec )pecial: r/ `/ L4 :omments CjC2Op 1 V Cif C Suffolk County Department of Health Services Bureau of Public Health Protection r. Plan Review Unit 360 Yaphank Ave,Suite 2A � Yaphank, NY 11980 CERTIFICATE OF APPROVAL CONSTRUCTION OR ALTERATION OF FOOD'SERVICE ESTABLISHMENT Approval is issued under the provisions of Article 13, Section 13,04 of the Suffolk County Sanitary Code Establishment Name Establishment Address Silver Sands Motel 1400 Silvermere Road Greenport, NY 11944 The Followinq Conditions Apply This approval is for the!.M:otel;-�Dine Motel-Lobby-Bar, Oyster Bar Kiosk, Boathouse Service Kitchen, Bldg. 33 Guest Se es location and the addition of two exterior walk-in refrigerators only • This approval does not constitute approval by any other state or local agency • This certificate is not a permit to operate a food service establishment.The operator must call the Department at 631-852-5999 to arrange an inspection of the completed construction prior to operation • The proposed construction is in conformity with the plans and specifications approved by the Department • Approval is based upon the application,plans and menu provided.Any changes require written approval from the Department of Health Services • This approval is valid for 2 years.Extensions may be granted upon written requestito the Department prior to the expiration date • The applicant shall comply with the following amendments to the plans and specifications: All locations: 1. Final approval from the Suffolk County Department of Health Services' Office of Wastewater Management is required before a pre-operational inspection can be conducted. 2. Properly plumbed and air-gapped indirect drains provided as necessary. 3. Adequate splash guards provided at hand wash sinks as necessary. 4. All Restroom doors must be self-closing 5. Surfaces of all floors,walls and ceilings must be finished to be nonabsorbent, smooth and easily cleanable Oyster Bar Kiosk: 6. Provide an adequate barrier between waste lines and any food or ware-washing related equipment and water storage tanks at the Ouster bar Kiosk 7. Shucked oysters at the ouster bar require mechanical refrigeration or the use of time as a public health control. 8. Awning covering the Oyster Bar must be waterproof. Suffolk County Department of Health Services �. b` . •.. Bureau of Public Health Protection �. Plan Review Unit - 360 Yaphank Ave,Suite 2A Yaphank, NY 11980 ` ' Boathouse Service Kitchen: 9. Boathouse Bar to be used as a service area only,with no patron access permitted (No patron toilet room available, refrigeration and ice machines accessible to bar area) Lobby Bar: 10. All Lobby Bar glassware and utensils must be washed in the dishwasher Diner: 11. Proof of parasite destruction required for Fluke (if served draw/partially cooked) and Bass Crudo (certain bass species) 12. Smoked bluefish must be commercially purchased (Smoking of bluefish on site requires a scheduled process) Building 33 Guest Services 13. Building 33 to contain a publically accessible bathroom for Oyster Bar patrons Issued for the Commissioner of Health Design ated.,Representative 6/8/2023 i Suffolk County Department of Health Services o` Bureau of Public Health Protection J Plan Review Unit ( . 360 Yaphank Ave,Suite 2A Yaphank, NY 11980 , NOTICE OF PLAN REVIEW CONSTRUCTION OR ALTERATION OF FOOD SERVICE ESTABLISHMENT Establishment Name Establishment Address Silver Sands Motel 1400 Silvermere Road Greenport, NY 11944 The Department has reviewed an application for construction/alteration of the above referenced establishment. It has been determined that the plans cannot bel approved at this time. Please review the items listed below and submit the requested information. Should you have any questions, please reach out to the reviewer directly. Additional Approvals Required Suffolk County Dept. of Waste Water Management has jurisdiction for all new construction and building additions with buildings discharging to septic or sewer systems, exterior walk-ins= building addition. ® SEWAGE SYSTEM REVIEW REQUIRED Please contact the Suffolk County Department of Health Services'Office of Wastewater Management at (631)852-5700. Approval from the Office of Wastewater Management is required before your food service plans can be approved. ® SEWAGE SYSTEM- FINAL APPROVAL IS REQUIRED Final approval from the Suffolk County Department of Health Services' Office of Wastewater Management is required before a pre-operational inspection can be conducted.Contact the Office of Wastewater Management at(631)852-5700 with questions.' I I PROJET er=- I 3 —__—__ / t< 7 LOCATION - e nwo. eEo. e"us M II' P LOCATION MAP 19•Sa'SO ' (Ow T W/Rhac Watn) GENERAL NOTES .. _ / ' vc®etnm¢ue,.m.vu,o,�a uw°nw nrtn N ; i.ewoura,twwr�°ramunw.giuene,,wuaama° SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES I LS d; �•----- I .00'ya�'. r 'Ip.. '�" 19„yV1 APPROVAL OF CONSTRUCTED WORKS DATE_ 7/19/2023 H.S.Ref.No. C-23-0169 The sewage disposal and water supply facilities Z . ' j Yr.w caw, •M1 x° -a- ,„;a,,, ,,,a at this location have been inspected and/or °,p,.�, a, certified by this found to be satisfactory and __ � r '1 I ,�,,,,,m,a �•• .0°.na a '��i `Y CRAIG KNEPPER.P E.,CHIEF A. I k w �'�wl� 0 R o fig; OFFICE OF WASTEWATER MANAGEMENT I .. *Final Approval for Walk-In Freezers only" ------'z5=----- d�_ ,.C.._.P i ':� Dao,> �. a Ae �ss• .> v,• 'p' II E���,I.rr � I F- � •.1� 0 98n. °°•, lest'. � "p� I _ --� w• v000s �m / %o It • ; ( a 1.9 I ..�1 iayy�y�- ec,�,®a-eu i °p` I'ji�`O 5'In w• pi it' I-_-- - Y•-- I I own �• � rs.""""°°' a----- aV$ •jam'-- ^i �'w°^z,; �Fo � � i•° _ LEGEND: F ,.q a, I ®=r ro lu.now,vv 5 03 ; i ZI--• ov cwEa e y b ' �• _ a aW�1EMPurt_ I--l-- If/ vr*.n..asrs I I � ,•;�=.,� `-11 5� � b I �. corcr�au�'rnw�wrvowm sw,a Q i $i I I A uOmMNrsEr s"; eru rom>n I �.I x„rw.,m u 3i wro �W j OI o ,t a s ��„�,muaraaaa X. 9J awcxerw ' mo,wwx e. a L y h] I mnl SaJ'16•W yl nm.... nr snr n --_ - axPaaE¢lyanv_ I I ...1 S ";ur w's wnaauLrtx¢ 51 AD R6. �acvraw y0at9;. o+Ex HEALTH DEPA11iNENTAPPR0VAL5TAMP ----------- 0 CE____ ,� t _ - Moyz°i •.._9x"+6� ma. w�a,mex,In �^ •Lae� ow.v i ligjl• W\ � W0009,NtF9fi 0 sR.uacax I .�.r i Iva r� \ nea•la•Jrw mvuv>: X3g i•2S,t>9�V151 561'38'OTW • ENDOFpPEtilONI015iNKf 260- P be; a �:'. ,' 3�. •�L' wETurvOnnGdwemut LTM :tg959'FEC./7 BLK2LTS b15 4l ly gj? N .� �at"N -�ER WwO SC0HSREF.NO_'C-ZMt99 �• - �• 9i2 }6 e pp i a�0 '1� s PTPES LOVE --seWRw x SILVER SANDS cE af. it Condon Engineering,P.C. a .._�«a.. nu bmRo2a HOLDINGS I LLC. OF SANITARYAS-BUILT tma>C sa 000SILVERMEREROAD W°�^•�6°^�•®"•+-r r:d^-++ GREENPORT NY S SN•9,',rw rxer as �,'•A6is''e'. afamwd,Ner Yak 17952 2399' W+L +.w%�r•.wur.rcmaamrt. (W1129fLi955(WIIE82651 rax .'�ow.a Nndaae++m•••...e'.P,.wasbWr�'r ry Decix82YJ ww,mW "�"""9�'" SANITARY AS-BUILT "on,� .Yorkers' CERTIFICATE OF INSURANCE COVERAGE --•L STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured INTERSTATE FIRE&SAFETY EQUIPMENT,INC. 75 CALVERT STREET 914-937-6100 HARRISON,NY 10528 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 061157138� 2.Name and Address of Entity Requesting Proof of 3a Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) HARTFORD LIFE AND ACCIDENT Town of Southold 3b Policy Number of Entity Listed in Box"la" 54375 Main Road PO Box 1179 LNY643810 Southold NY 11791-0959 c Policy effective period 04/01/2022-04/01/2023 4.Policy provides the following benefits: 0 A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5.Policcovers: L✓J A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 04/01/2022 7e_ '�j- (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (212)553-8074 Name and Title:Elizabeth Tello—Assistant Director,Statutory Services IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law.It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board (Only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed B (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 11111111 DE-i-90.1 (10ll l.11'lll IH Additional Instructions for Form D13-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in box"1 a"for disability and/or paid family leave benefits under)the New York State Disability and Paid Family Leave Benefits Law. The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to-nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices my be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Disability and/or Paid Family Leave Benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or paid family leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of NYS Disability and/or Paid Family Leave Benefits Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Disability and Paid Family Leave Benefits Law. DISABILITY AND PAID FAMILY LEAVE, BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first, two thousand and twenty-one, the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b) The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any'such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand eighteen, the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1(10-17)Reverse YORK Workers' CERTIFICATE OF STATE Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Interstate Fire and Safety Equipment Co.,Inc. (914)937-6100 75 Calvert St. 1 c.NYS Unemployment Insurance Employer Registration Number of Harrison,NY 10528 Insured 52603226 Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 06-1157138 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Everest National Insurance Company 3b.Policy Number of Entity Listed in Box"1 a" Town of Southold 54375 Main Road 5300002665-221 PO Box 1179 3c.Policy effective period Southold NY 04/01/2022 to 04/01/2023 11791-0959 3d.The Proprietor,Partners or Executive Officers are �X Included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. e This certifies that the insurance carrier indicated above in box"T'insures the business referenced above in box 1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period? YES [:]NO This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Christopher McGovern (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 04/01/2022 (Signature) (Date) Title: Senior Vice President All Risks Ltd. Telephone Number of authorized representative or licensed agent of insurance carrier: 800-366-5810 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9-15) www.wcb.ny.gov A�1 CERTIFICATE OF LIABILITY INSURANCE DATE7/27/2023 Y) 07127/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Christine Schuller NAME: AssuredPartners Northeast,LLC. PnHCNNo Ext: (631)844-5178 C,,,): (631)465 4005 100 Baylis Road E-MAIL chris.schuller@assuredpartners.com ADDRESS: Suite 300 INSURER(S)AFFORDING COVERAGE NAIC# Melville NY 11747 INSURERA: Fortegra Specialty Insurance Co. 16823 INSURED INSURER 8: Merchants Mutual Ins.CO. 23329 Interstate Fire&Safety Equipment Co.,Inc. INSURER C: Merchants National Insurance Company 12775 INSURER D: State Insurance Fund-NY 36102 75 CALVERT ST INSURER E: Endurance Assurance Corp 11551 Harrison NY 10528 INSURER F: Illinois Union Insurance Co 27960 COVERAGES CERTIFICATE NUMBER: `23-24' REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY EFF POLICY EXP LIMBS LTR INSD WVD POLICY NUMBER MM/DD MMIDD X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE % OCCUR PREM SESOEa occu ante $ 100,000 X Contractual Liability MED EXP(Any one person) $ 5,000 A Y Y FMC-CGL1000844-00 04/01/2023 04/01/2024 PERSONAL&ADV INJURY $ 1,000,000 GEN'LAGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY ❑X ECT PRO- FLOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident X ANYAUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED Y Y CAP9270145 04/01/2023 04/01/2024 BODILY INJURY(Per accident) S AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAB X OCCUR EACH OCCURRENCE S 2,000,000 C X EXCESS LIAB CLAIMS-MADE Y Y EXL0003468 04/01/2023 04/01/2024 AGGREGATE $ 2,000,000 DELI I X RETENTION$ 10,000 $ WORKERS COMPENSATION X1 PER STATUTE ERH AND EMPLOYERS'LIABILITY Y/N 500,000 ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACHACCIDENT $ D OFFICER/MEMBER EXCLUDED? ,N/A Y W 2587 725-9 04/01l2023 04/01/2024 (Mandatary in NH) E.L.DISEASE-EA EMPLOYEE $ 500,000 If yes,describe under 500,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Excess Liability E Y Y EXC30001868603 04/01/2023 04/01/2024 Occurrence 5,000,000 Aggregate 5,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached if more space is required) The following are included as additional insured if required by written contract subject to the terms and conditions of stated policies:Silver Sands Motel& Beach Bungalows General Liability,Auto,Umbrella,&Pollution coverage apply on a primary&non-contributory basis with a waiver of subrogation in favor of additional insured's CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Silver Sands Motel&Beach Bungalows ACCORDANCE WITH THE POLICY PROVISIONS. 1400 Silvermore Rd. AUTHORIZED REPRESENTATIVE Greensport NY 11944 @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD AGENCY CUSTOMER ID: LOC#: ACbR" ADDITIONAL REMARKS SCHEDULE Page of AGENCY NAMED INSURED AssuredPartners Northeast,LLC. Interstate Fire&Safety Equipment Co.,Inc. POLICY NUMBER CARRIER NAIC CODE EFFECTIVE DATE: ADDITIONAL REMARKS THIS ADDITIONAL REMARKS FORM IS A SCHEDULE TO ACORD FORM, FORM NUMBER: 25 FORM TITLE: Certificate of Liability Insurance:Notes Insurer(f)Illinois Union Insurance Company Policy#CPYG4739899A 001 Pollution Liability EFF 4/1/23-4/1/24 $1,000,000/$2,000,000 1 OK Deductible I I ACORD 101(2008/01) © 2008 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD .:.ixi..•,,+„'qr+;c ,3X..''a'K:'�.w.i:w.m-n;;.r;:-��WS-i�•n:,X:r+ttc5'1ix±,r..,.,scp z;?%5- ..-.r „: .. L-; �y - aa It is hereby certified that ii t William Barnes,Jr. ti INTERSTATE FIRE AND SAFETY-HARRISON F '3 Has successfully completed the training course for �i ANSUL R-102 Restaurant Systems ALT Final Certification Exam: Design, Installation, Recharge and Certificate of Maintenance >k T'ra 1 n 0 n g Completed this 3/23/2021 This certificate is considered valid for a period of three years from completion date and linked to the attendee and the company mentioned above. �s Training Hours:8 P. Katherine A.Adrian ~( -eih� a. an]7r3:::,<Cai\i.:e" }x Johnson r. Controls ._.^tra; A.,nght r;wea r.' t. - :..�.,sT-":ryy,�l.: .-w'••Y:efN .519%1'Av:A!'p:\;.T:S�'!�y t.+,�:,.yt}�?l�f'•Ki�� - SUFFO:LK COUNTY _ DEPARTMENT OF FIRE,, RESCUE ,AN'D EMERGENCY SERVICES PORTABLE-FIRE =EXTING.UISHER.AND AUTOMATIC FIRE EXTINGU•ISWNG SYSTEMS LICENSING BOARD CERTIFICATE -OF, RE:GISTRATIOIV REGISTRATION #: 111 EFFECTIVE DATE: 03118/20217;; =_``': _ �'� � " � j ' .:.EXPIRATION DATE: 03/31/2023 ISSUED TO: . . '-NAME: R ark C,°rp dU ABT Design-and°Fire`I?rotecti•on ADDRESS: :1724.yChurch`Street_�T = Y; :. -H:olbrook. NY�`11741 _. ENDORSEMENTS: :. Portablel�Fire Extinguishers - - -- Dry/NetChemical Extinguishing Systems` g, t` 1� III 1E ii IN1 I� r MAR 2 8 2023 This.Certificate.of Registration Does Not Exclusivel 'Recommend the-�B' Ue PT _ . COMMISSIONER CHIEF FIRE MARSHAL 1 i Client#:776522 RIARKCOR DATE(MM/DD/YYYY) ACORD.. CERTIFICATE OF LIABILITY INSURANCE 5/15/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorse'meni(s). PRODUCER NAME CT Yarden Bleicher US[Insurance Services-C/L PHONE 516 419-4000 a No; 877 727-5171 A/C No,Ext: 725 RXR Plaza East Tower E-MAIL ADDR ESS: yarden.bleicher@usi.com 7th Floor INSURER(S)AFFORDING COVERAGE NAIC# Uniondale,NY 11556 INSURER A:Admiral Insurance Company 24856 INSURED INSURER B:Century Surety Company 36951 Riark Corp.dba ABT Design& INsuRERc;Republic Franklin Insurance Company 12475 Fire Protection INSURER D 1724 Church Street I INSURER E i Holbrook,NY 11741 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LIMITS LTRVGENT TYPE OF INSURANCE INSR WVD POLICY NUMBER MMIDD MMIDD/YY AMERCIAL GENERAL LIABILITY CA00004188403 5115/2023 05/15/202 EACH OCCURRENCE $1 00O 000 CLAIMS-MADE I—J OCCUR PREMISES Ea occurr°nee $300 000 PDDed:10000 MED EXP(Any one person) $5,000 PERSONAL&ADV INJURY $1,000,000 GREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 ®PROPOLICY EC LOC PRODUCTS.COMP/OPAGG $2,000,000 OTHER: COMBINED SINGLE LIMIT C — 1�000�000 AUTOMOBILE LIABILITY I 4749790 4/27/2023 04/27/202 Ea accident $ ANY AUTO ANY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY X AUTOS PROPERTY DAMAGE HIRED NON-OWNED Peraccidenf $ X AUTOS ONLY X AUTOS ONLY j $ B UMBRELLA LIAB Xd OCCUR I CCP1148014 5/15/2023 05/15/202 EACH OCCURRENCE $1 00O 000 5X EXCESS LIAB CLAIMSMADE AGGREGATE $1 00O 000 DED RETENTION$ i $ WORKERS COMPENSATION PER ER_- AND EMPLOYERS'LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) RE:Client#776522 The General Liability policy includes an automatic Additional Insured endorsement that provides Additional Insured status to Certificate Holder,only when there is a written contract that requires such status,and only with regard to work performed by or on behalf of the named insured. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. Town Hall Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016103) 1 of 1 The ACORD name and logo are registered marks of ACORD #S40075338/M40067345 HESZP Client#:776522 RIARKCOR ACORDTM CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 5/16MIDDN THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Yarden Bleicher NAME: USI Insurance Services-C/L PHONE 516 419-4000 FAX 877 727-5171 725 RXR Plaza East TowerE-MAIL Ext: A/c,No ADDRESS: yarden.bleicher@usi.com 7th Floor INSURER(S)AFFORDING COVERAGE NAIC# Uniondale,NY 11556 INSURER A:Admiral Insurance Company 24856 INSURED INSURER B:Century Surety Company 36951 Riark Corp.dba ABT Design& INSURER C:Utica National Assurance Company 10687 Fire Protection INSURER D: 1724 Church Street INSURERS: Holbrook, NY 11741 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE,INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER MM/DD/YYYY MM/DD/YYYY A X COMMERCIAL GENERAL LIABILITY CA00004188402 5/15/2022 05/15/2023 EACH OCCCURRENCE $1 OOO OOO CLAIMS-MADE �OCCUR PREMISES Ea occur°nce $300 000 X BI/PD Ded:10000 MED EXP(Any one person) $5 000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY 1 PROT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ C AUTOMOBILE LIABILITY 4749790 4/27/2022 04/27/202 COMBINED SINGLE LIMIT Ea accident 1,000,000 ANY AUTO BODILY INJURY(Per person) $ OWNED Ix SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS XHIRED ONLY NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY Per.accident B UMBRELLA LIAB X OCCUR CPP1062104 5/15/2022 05/15/2023 EACH OCCURRENCE $1 000 000 X EXCESS LIAB CLAIMS-MADE AGGREGATE $1 OOO 000 DED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? ❑ N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) - DII[ IL, I� �� IUI ►� I MAR 2 8 2023 , CERTIFICATE HOLDER CANCELLATION Town Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. Town Hall Southold, NY 11971 AUTHORIZED REPRESENTATIVE 01988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 Of 1 The ACORD name and logo are registered marks of ACORD #S35971607/M35967883 MCMZP NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE 0 0 ^^^^^^ 562457472 USI INSURANCE SERVICES LLC . 725 RXR PLAZA ' f EAST TOWER UNIONDALE NY 11556-3645 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER RIARK CORP T/A TOWN OF SOUTHOLD ABT DESIGN&FIRE PROTECTION TOWN HALL ANNEX BUILDING 1724 CHURCH STREET 54375 ROUTE 25; PO BOX 1179 HOLBROOK NY 11741 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOQ DATE 11169 034-4 68533 02/03/2023 TO 02/03/2024 3/24/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 1169 034-4, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/NVWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. I� IL�, ►cn ;u/ I� MAR 2 8 2023 ��19+�1.)1114da . �i'6Vl�i IJ or qny mwo.4 NEW YORK STAT SUR NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 768344488 U-26.3 f' #0L K C O AT DEPARTMENT OF FiR RpsC E AND E ERGP_NCY SERVICES . UIZHER AND .UOMATIGFR_E.PORTABLE �E EXTt� � . C S�SI �JS � � TEmS I®IOENSIIVC� BOAR REGISTRATION #: : T22 EFFECTIVE DATE: ...2/17/2022... . EXPIRATION DATE- 2128/2024, ISSUED TO:. . ; . NAME: Interstate Fire:&:Safety Equipment-Company; Inc. ADDRESS: - 75 Calvert Street Harrison,.NY 10528 ENDORSEMIEIVTS.: Portable Fire-Extinguishers. . ' 'DryM/et Chemi:cai. Extinguishing-Systems -- . High;P:ressure Hydrostatic Testing Clean'Agent.Extinguishing Systems Cei tificate of Re istration Does-Not Exclusives Recommend the Bearer x. r. ACTING COMMISSIONER `CHIEF FIRE MARSHAL Water Heater Requirements ®WATER HEATER - Dirier lectriflex LD28 GAL 5 KW is sufficient to service the Diner 3 comp sink, 1 hand sink and 4 bathroom handsinks without a pre-rinse spray at the dishwasher. I - ALobby bar OBradford White LE240LN3-3 is sufficient to service the Lobby Bar Dishwasher and 1 hand wash sink - Boat House: AO SMITH DRE 80 Gal 40.5 kw is sufficient.This requirement was calculated using both dishwashers and the three comp sink(3-20 x 20 x 8" basins), 1 bar 3 comp sink,2 hand sinks and 2 bathroom hand sinks, 1 shower in the living quarters and 1 kitchen sink. ®DEPARTMENTAL NOTES:CONDITIONS OF PLAN APPROVAL WILL BE: 1. Properly plumbed and air-gapped indirect drains provided as necessary. 2. Provide an adequate barrier between waste lines and any food or ware-washing related equipment and water storage tanks at the Oyster bar Kiosk 3. All Lobby Bar glassware and utensils must be washed in the dishwasher 4. Adequate splash guards provided at hand wash sinks as necessary. 5. Shucked oysters at the oyster bar require mechanical refrigeration or the use of time as a public health control. 6. All Restroom doors must be self-closing 7. Boathouse Bar to be used as a service area only, with no patron access permitted (No patron toilet room.available, refrigeration and ice machines accessible to bar area) 8. Proof of parasite destruction required for Fluke (if served raw/partially cooked) and Bass Crudo (certain bass species) 9. Smoked bluefish must be commercially purchased (Smoking of bluefish on site requires a scheduled process) 10. Surfaces of all floors, walls and ceilings must be finished to be nonabsorbent, smooth and easilv cleanable 11.To be determined PLEASE NOTE. WHEN RESUBMITTING PLANS THAT CONTAIN MULTIPLE PAGES, ONLY THE REVISED PAGES ARE REQUIRED. APPLICATION REVIEWED BY Suzanne Fiumano 6/2/2023 PHONE: (631)852-5863 E-mail: suzanne.fiumano@suffolkcountyny.gov CELL: (631)637-2271 I Rev. 12/20 � � Centrifugal Upblast Exhaust Fans Centrifugal Upblast Roof Exhaust Fan... Centrifugal Upblast Roof Exhaust Fan: Belt Drive, 16 TOWN OFSOUTHOLD 1/2 in Wheel, 2,774 cfrn, I This item requires special shipping, i additional charges may apply. Qty Item 7A623 Mfr. Model 7A623 Add to Cart I � � -_- -^e�. -` | | Setup Auto Reorder Not available when pickup is selected ! Product Details Catalog Page OA53 \ Pickup For Air Type Kitchen Air � �---------� | -- — --- - -- ---- - -----'------ | | -----'----- -- ----' - -- �� Pinkupdateiounovai|ob|e. Drive Type Belt Drive == --------'-----�--�---'--------'-------'----------'-'--' --- ------ Bohemia Branch#54B | Assembly Unassembled Change |nn|udoa Drive Package with Motor Yen ----- ---''----�--'----'- ------�------------------'----'---'--------'--- '----'-'---- 1 Pickup Weight 87.90|ba � Wheel Diameter 16'1/2in Exhaust Airflow @U.00OinSP2,774ofm [ ----- -- ----''' ---) Add to List ' ------------------------�---------'--- | ' --------' ----' --� / Exhaust Airflow @0125inSP2,637cfm Exhaust Airflow @ 0.250 in SP 2,477ofm Alternate Products 0 Exhaust Airflow @0.376inSP2,3ODofm --� --- ---------'----- --- -------'-------------------- ----'---------'----- ---'-' ------ i Exhaust Airflow @O.5OUinSP2,1Ogufm ! ------------'-------------- --------- ------------------------ ' .'C��� Maximum Static Pressure 3/4inwo � --__-__-----------'--''------'--------�- ---------- - - ------ ---- Centrifugal Upb|ootRoof | | For High-Static Pressure Applications No Exhaust Fan:Belt Drive, 14 / ---'----------------------- -- '------------'- ------------ ! 3/4in Wheel,2,518cfn,ODR Nameplate Voltage 116/3OO'230VAC | 1/3 hp,1-ph � '---�--'---------- ' --- ---------------'-------- -- - ----- Item 7A62O ' Phase ----------------------------- --'------------- -------'------' Your Price �� ' Frequency 6OHa �� $675.11 /each Current 6.6/3.4 to 3.1 A QtyEAdd to Cart i / / ----------------'---------------- | Motor Horsepower 1/3hip L------J ! / �--------�----- ----- --------- --------------'-'�'------- ---- L_'_ _____-.� _-___-___-� Brake Horsepower 7/2Dhp Motor Speed 965 RPM Maximum-------`----------`-----------`--------`-------' ----`---- Maximum Fan Speed 965RPM Motor Enclosure Open Drippnmof ---------------------'---- ------------ -- -- ---'-'--�----'------' / �� Chat with anAgent \ Motor Location Out ofAirstream \ ' High-Efficiency Motor No Speed Controllable No Number of Speeds 1 Wheel Type Backward Inclined Wheel Material Aluminum Housing Material Aluminum Housing Material Fabrication Spun Maximum Inlet Air Temperature 300°F Base Shape Square Base Height 1.8 in Base Width 26 in Base Length 26 in Overall Height 28-1/8 in Bearing Type Sealed Pillow Block---___...__.._..-.___._..___._—_..—__ Damper Size 19 x 19 in Mounting Location Roof Mount Type Roof Curb Application Industrial and Commercial Buildings;Restaurants;Schools Standards AMCA Sound and Air;UL/cUL 762 Includes Drive Package;NEMA 1 Junction Box Compatible Curb Grainger Part Number 2RB77;2ZV83;3C437;4C454;4HX40;4HX48;4HX56;4HX62 Compatible Damper Grainger Part Number 4HX66 Sound Level 10.5 sones @ 0.750'in SP;10.6 sones @ 0.625 in SP; 10.8 sones @ 0.500 in SP; 11.2 sones @ 0.375 in SP; 11.5 sones @ 0.250.in SP; 12.0 sones @ 0.125 in SP; 12.4 sones @ 0.000 in SP Brand DAYTON Features Air Handling Quality Bearings Meet Minimum of L10-100,000 Hours; Nonoverloading Centrifugal Wheel Design UNSPSC 40101502 Country of Origin Varies(subject to change) Product Description Kitchen air belt-drive fans with drive help to ventilate a kitchen or similar environment with grease-laden or humid air.These fans come with a drive package that includes a motor,sheaves,belts,and bushings. Fans intended for use with heavy grease feature steel propellers and housings which are easier to clean and are less reactive to cleaning chemicals. Belt-drive fans are typically quieter and provide Chat with an Agent more control over the fans'blade speed and airflow than direct-drive fans. t . KG'RAINGER. Filtered Supply Fans / Centrifugal Roof Supply Fan:11 1/8 in... :-- — ---- ------------- Centrifugal Roof Supply - Fan: 11 1/8 in Wheel, 2,156 _ cfm, 1/2 in we Max., ODP, I This item requires special shipping, 1/3 hp, 1 Ph additional charges may apply. i Qty Item 7D496 Mfr. Model 713496 1Add to Cart Motor Enclosure Design-Broad Open Dripproof Motor ( Setup Auto Reorder j Not available when pickup is I Open Dripproof I selected Motor �..- ---- ----- -- - -- - - - ShipPickup Totally Enclosed 0 0 p Motor I I ® Pickup date is unavailable. Product Details Catalog Page 2962 ; Bohemia Branch#548 Change Drive Type Belt Drive - --- -- - -- i Pickup Weight 181.93 Ibs Includes Drive Package with Motor Yes I Assembly Unassembled Add to List Wheel Diameter 11-1/8 in ..... --------------- ------- ---_-____I Supply Airflow @ 0.000 in SP 2,156 cfm ® Alternate Products Maximum Static Pressure 1/2 in we Maximum Inlet Air Temperature 120°F ------------ Nameplate Voltage 115/208-230V AC Centrifugal Roof Supply Fan: Phase 1 11 1/8 in Wheel,1,954 cfm, ----- - -----_------- - -- - - - ---- -- ------- -- - - - --- 3/8 in we Max.,ODP,1/4 hp, 1 Motor Enclosure Open Dripproof ; Ph --- ------------ ------ --- ---- ------ - - -_-- Item 7D495 Motor Horsepower 1/3 hp j Brake Horsepower 39/100 hp j Your Price I -------------------- -__._----- -- - -- -_ _-- ----- --------__._'_-- -- --------------- � $1,751.69/each Motor Speed 1,725 RPM Qty ----------- ---- -- ----- ------ - - Add to Cart Maximum Fan Speed 760 RPM - Frequency 60 Hz i Current 6.6/3.4 to 3.1 A Speed Controllable No 1 Number of Speeds 1 -- ----------- --- -- — -------- -- — ----- - --— -- Chat with.an Agent ---- Bearing Type Sealed Pillow Block — (, Mount Type Roof Curb i Mounting Location Roof and Wall -------- -----__ — ------- ------- - ---------- Centrifugal Roof Supply Fan: Wheel Type Forward Curved 11 1/8 in Wheel,2,468 cfm, ---------- — ------------- ----------- -- -----------------.---- j 5/8 in we Max.,ODP,1/2 hp,1 � Wheel Material Steel j Ph Filter Material Aluminum Item 7D497 Number of Filters 1 i Your Price ---------- ------- ---------- -- ----- --- -... ------ -- ..._ - -- ; $1,266.02/each Filter Area 4-1/8 sq ft I U Qty ------------------------------------------- -------- ------- ------- 1 Add to Cart Filter Housing Height 21-1/4 in Filter Housing Width 21-1/8 in -- - - ----- - -- ---- Filter Housing Depth 22 in Housing Material Steel Base Shape Square Base Height 1.5 in Base Width 30 in Base Length 30 in Overall Height 25 in Overall Length 30 in Overall Width 52 in Includes Drive Package;Washable Aluminum Filters Application Commercial Kitchen; Institutional Buildings Spark Resistant Construction Type A Standards AMCA Sound and Air;UL/cUL 705 Compatible Curb Grainger Part Number 2RB79;2ZV83;3C437;4C454;4HX41;4HX49 Housing Finish Galvanized Brand DAYTON Features Air Handling Quality Bearings Meet Minimum of L10-100000 Hours;Neoprene Isolators Minimize Vibration and Noise UNSPSC 40101501 Country of Origin Varies(subject to change) Product Description Belt-drive filtered supply fans provide filtered supply air to indoor commercial spaces.These fans come with a drive package that includes a motor,sheaves,belts, and bushings.They feature washable aluminum filters and a weather hood that makes maintenance simple and fast. Belt-drive fans are typically quieter and provide more control over the fans'blade speed and airflow than direct-drive fans. ® Chat with an Agent A W", OI I l Ceramic* FastWrap@ XL � Commercial Kitchen Grease Duct AIR" l�� Fire Protection Products Product Data & Installation Guide �0o '� 1. Product Description Q. i s Thermal Ceramics new FireMaster® FastWrap XL is the thinnest , and lightest flexible wrap material available that passes the ASTM E2336 test standard required by the 2006. IMC and NFPA 96 for reduced clearance enclosure materials used to :�• ` provide 1 or 2 hour fire rating for kitchen exhaust ducts. The ; FastWrap XL core blanket is manufactured -using Thermal ,+r,4; Ceramics' patented SuperwoolO fiber, a 2000°F rated, non-corn- bustible, alkaline-earth silicate wool with low biopersistence. J}' FastWrap XL is the product of extensive research and development resulting in break-through improvements in fiberization technology with significant enhancements in thermal properties beneficial to fire protection applications. FastWrap XL when used in combination with an approved firestop sealant provides an effective through penetration firestop in rated floor and wall assemblies. FastWrap XL is UL Classified and is part of UUs Listing and Follow-Up Service 4. Performance Specifications Program to ensure the consistent quality essential to the critical Reference.Standard Standard No. Performance nature.of this life-safety application. GreaseDuct Enclosure System ASTM E2336 Pass Product Features Y •Approval as a 1 or 2 hour shaft alternative in kitchen grease duct Section 16.1 -Non= ASTM E136 Pass applications Combustibility •Zero clearance to combustibles at any location Section 16.2-Fire •Thin and Lightweight at 1%inch thick,6 pef density Resisteance (wall) ASTM E119 Pass n •Contours easily to complex duct designs Section anc - • Butt Joints on inside layer to save labor and material Durability Test ASTM C518 Pass • Fully foil encapsulated for fast and clean installation •Completely inorganic and non-combustible Section 16.4- ASTM E2336 Pass •Contains 2000°F rated fibers for added safety margin Internal Fire Test •Contains no low temperature mineral or glass fibers Section 16.5- Fire ASTM E814/E119 Pass •Wide variety of through penetration systems Engulfment(duct) •Resistant to mold growth(ASTM D6329) Surface Burning Characteristics •Extensive Listings and detailed installation instructions • Recognized and accepted by inspectors requiring less job-site Flame Spread ASTM E84 510 engineering judgments (foil/blanket) •Available in space saving 50 and 100 square foot rolls for optimal Smoke Developed ASTM E84 5/0 job-site storage (foil/blanket) •Available in 48 inch widths for less joints and installation labor Thermal Resistance ASTM C518 (70F) 4.2 per inch 2.Applications (R-value),, •Applied in 2 layers to provide 1 or 2 hour fire protection to grease Mold Growth (75% ducts exhausting Type 1 hoods per IMC 2006,NFPA 96 and 2006 humidity) ASTM D6329 Resistant IAPMO UMC Mold Growth (95% ASTM D6329 JResistant 3. Physical Characteristics humidity) Duct FireMaster Units/Wt./ 5. Listings/Building Code Reports Fire Protection [Roll it size Ctn. Ctn. Listed Uses Agency Listing Product Grease'Duct Enclosure System (Zero UL G18 FastWrap XL 1!•x 24"x 25' 1 37.5 lbs. Clearance) -AC101 (ASTM E2336) Grease Duct Enclosure System (Zero ICC-ES' ESR 2213 FastWrap XL Roll 1X"x 48"x 25' 1 75 lbs. Clearance)-ASTM E2336 Through Penetration FireStop System UL C-AJ-7119 FastWrap XL Collar Roll 1h"x 6"x 25' 4 37.5 lbs. -ASTM E814/UL 1479 Color White blanket with silver foil encapsulation *International Code Council -Engineering Service Morgan Crucible Thee at Ceramics 3.Storage: C. 2&3 Sided Wrap Installation (Figure 1) Fa's;Wrap XL must be stored in a dry warehouse environment on When space does not allow for a complete wrap applied to the duct pallets. Pallets should not be stacked. on all four sides,the FastWrap XL is approved for 2 or 3 sided,instal- lations with mechanical attachment to a concrete or CMU assembly. 7. Installation The FastWrap XL is installed on the 2 or 3 sides of the duct as FastWrap XL shall be installed by a qualified contractor in accor- described in one of the installation methods described in sections A dance with manufacturer's instructions and referenced standards. or B with the starting edge of the blanket attached to the concrete or See figures 1 to 5 for complete details. CMU assembly and then wrapped around the duct until the other Materials and Equipment: end can be affixed to the other concrete or CMU assembly, thus FastWrap XL blanket encapsulating the duct with insulation around all accessible sides. •Aluminum foil tape The blanket is to flange out onto the concrete or CMU assembly. It • Minimum X"wide filament tape(optional) shall be secured to the adjoining assembly with min'/,e"diameter,4" •Carbon steel or stainless steel banding material,minimum'!:"wide, long concrete anchors, footed to a minimum 1W' wide x 3/,6' thick minimum 0.015"thick,with steel banding clips steel strip/strap with pre-drilled holes spaced a maximum 10" on • Hand banding tensioner and crimping tool center. The steel strip is to be placed around the entire perimeter of • Minimum 12 gage steel insulation pins;steel speed clips,minimum the duct in the exposure area. The FastWrap XL insulation wrap is 1X"x 1V"square or 1W'dia.,or equivalent sized cup-head pins; secured to the duct with minimum 34"wide steel banding 10V'cen- •Capacitor discharge stud gun ters. The ends of the banding are to loop into the steel strips/straps •FireMaster F2-HT-XL3 Prefabricated Door or Field Fabricated that foot the,blanket to the concrete floor or wall, and tightened Door Hardware down. The trapeze support system may be incorporated within the •An approved firestop sealant wrap system: General: D. Mechanical Attachment Methods for Insulation Wrap To minimize waste, FastWrap XL blanket should be rolled out tautly 1.Banding(Figure 2)-Minimum 3,�"wide carbon steel or stainless before measuring. Cut edges of the blanket shall be taped with alu- steel banding,0.015" thick,is placed around the entire perimeter of minum foil tape to prevent exposed edges of the insulation from the insulated'duct with maximum 10W"spacing centers and 1 V"from wicking moisture from condensation or grease from a compromised each blanket edge or 134"from each collar edge when using the butt leaking duct joint into the material and causing degradation of the joint and collar method. When banding,filament tape can be used fire barrier. Overlaps are used to block heat transfer in the event of to temporarily hold the blanket in place until the banding is applied. duct deformation resulting from thermal expansion. FastWrap XL The banding is placed around the material and tightened so as to blanket may be installed with either a mechanical banding system or firmly hold the FastWrap XL in place against the duct,but not cause insulation pins and clips (see Mechanical Attachment Methods any cutting or damage to the blanket. below and figures 1 and 2). Support hanger systems do not need 2. Pinning (Figure 3)-For duct spans 24"or larger,min. 12 gage, to be wrapped provided that the hanger rods are at least a minimum 5„ long steel insulation pins are welded to the duct in columns of W diameter and spaced a maximum of 60" on center along the spaced 12" apart, 6" - 12" from each edge and on 10h" centers length of the duct, and the angle iron is a minimum of 2"x 2"x /a" along bottom horizontal and outside vertical runs to prevent blanket or SMACNA equivalent support system (SMACNA band strap sup- sag. Pins are also required 1"from the end of a duct and 1"from port do not apply). Horizontal trapeze support system may be incor- any edge near a 90' bend, spaced on 6" centers. Pins are locked porated into the wrap enclosure. into place with 1X" diameter round or square, galvanized steel, A. First Layer—Butt Joint(Figure 2) speed clips or cup head pins. Pins that extend beyond the outer The first layer of FastWrap X12 is cut to completely wrap around the blanket wrap layer shall be turned down to eliminate sharp edges or perimeter of the duct with enough excess to provide a tight butt joint the excess length cut off. where the blanket ends meet. The joints of adjacent blankets are E. Grease Duct Access Door Installation (Figure 4) firmly butted against each other. This interior layer can be held tem- Four galvanized steel threaded rods,X"diameter by 4:'to 5"long porarily in place with filament tape spaced 1-1/2"from each blanket are welded to the duct at the corners of the door opening. Four 4" edge, and spaced on nominal 10-1/2" centers along the center of long steel tubes fit over the threaded rods to hold the door to the the blanket. While not required, the inside layer can be installed duct and protect the wrap from damage as the door is removed. with 3"overlaps along perimeter and adjacent blankets. Four 5" long 12 gage insulation pins are welded to the door panel B. Second Layer—3" Overlap, or 6" Collar(Figure 2) for installation of the blanket. Three layers of FastWrap XL are The second layer of FastWrap XL is cut to completely wrap around impaled over the 12 gage insulation pins on the 16 gauge door the perimeter of the first layer,with enough excess to overlap itself panel and held in place with speed clips.Each layer must have min- not less than 3". Joints in the second layer should be staggered a imum 1"overlap over the previous layer. When the door is"installed, minimum of 12 inches from joints on the inner layer. Adjacent blan- this first and second layer must fit tightly against the wrap surround- kets on the second layer must overlap each other by not less than ing the door opening to form tight butt joints. Pins that extend 3". As an alternative to overlaps on adjacent blankets installed on beyond thel outer layer of FastWrap XL shall be turned down to the second layer, adjacent blankets can be tightly butt jointed and avoid sharp'ipoints on the door. The steel tubes are placed over the wrapped with a 6"wide FastWrap XL collar centered over the butt threaded rods. The insulated door panel is placed over the thread- joint. This outside layer can be held temporarily in place with fila- ed rods covered by the steel tubes and held in place with washers ment tape spaced 1 V'from each blanket edge,and spaced on nom- and wing nuts. FireMaster F2-HT-XL3 Access Doors are tested and inal 10%" centers along the center of the blanket. Mechanical approved per ESR 2213 as alternatives to field fabricated doors. attachment as described in Section D must be used to make the Installations instructions for the F2-HT-XL3 door are included with installation permanent the complete assembly. F.Through-Penetration Fire Stop System (Figure 5) 9. Maintenance and Repair When the duct penetrates a fire rated wall, ceiling, or floor, an No maintenance is required when installed in accordances with approved fire stop system must be employed. Thermal Ceramics installation instructions. Tremco Inc. Fyre Sil®or Fire Sil S/L If damage is limited to the foil facing,aluminum foil tape can be used Sealant to repair the foil facing. Specificed Technologies Inc. Pensil®300 If an area of blanket is found to be damaged the following procedure Rectoseal 835+TM Sealant must be incorporated. HILTI Inc. FS One TM Sealant • If the damaged area is larger than 8"x 8"the entire wrap section must be removed and replaced according to Thermal Ceramics Prior to installing this firestop system the surfaces of all openings and installation instructions, penetrating items needs to be clean and dry. •If the damaged area is small(less than 8"x 8"),the damaged area Cut the aluminum scrim,facing off FastWrap XL blanket to expose the must be cut away and replaced with a new section 1"larger in length core blanket. FastWrap XL scrap blanket must be packed into the and width'than the cut out are, such that the new section can be annular space at minimum 50% compression. The packing material compressed tightly into the cut out area. All cut edges of the new must be recessed a minimum YV from the surface of the concrete or section must be taped and sealed wth aluminum foil.tape. The new gypsum wall. Install a minimum of '.' of approved firestop sealant section must be held in place with either pinning or banding per into the recessed opening. When there is no room in the remaining Thermal Ceramics installation instructions/ annular space to wrap the duct with FastWrap XL material, the enclosure may terminate above and below the floor/ceiling or wall 10. Limitations assembly as shown in figure 5 by mechanically attaching the °Thermal Ceramics FastWrap XL shall be installed in accordance FireMaster to the termination point above and below the termination with these installation instructions. The integrity of FastWrap XL area with bands or pins. systems is limited to the quality of the installation. 'For personal protective equipment recommendations see the MSDS. Thermal Ceramics is a trademark of Morgan Crucible Company plc. FireMaster and FastWrap are trademarks of Thermal ceramics Inc. FastWrap products are manu- factured by Thermal Ceramics Inc.and are distributed by authorized distributors. Tremco and,Fyre-Sil are trademarks of Tremco Inc. Thermal Ceramics Thermal Ceramics FireMaster FastWrap XL 2 Sided Wrap Detail for FireMaster FastWrap XL 3 Sided Wrap Detail for Attaching to Walls/Ceilings 1 or 2 Hour Attaching to Walls/Ceilings 1 or 2 Hour Grease or Air Duct Grease or Air Duct 3' 5 1 1 3 3 - 4 4 8 8 7 7 2 6 3 2 6 Figure 1 1. Concrete slab 5. Air gap (8" maximum) 2. Two layers FireMaster FastWrap XL 6. Duct 3. Concrete fastener system 7. Steel banding 1/2"wide minimum 4. 118"thick x 2%3"wide bar stock per- 8 Banding clip forated 12"o.c. A Thermal Ceramics 11� FireMaster FastWrap XL Commercial F itchen Grease Duct System 1 or 2 Hour Shaft Alternative Zero Clearance to Combustible 17.E 2 (4 x } :j,,.a -u.tz•:>sx:r.-n-..eug+,�`k^.•,z'::r.+:xb,rae:.rRavi7� ;i.•n•....s..re..�:r_-,n>,•.vr...tn..+r..xx...e»...+,.x_•.h.r,me.-..i � BUTT.JO N, AR Figure 2 1. Two layers FireMaster FastWrap XL 2. Steel banding 112"wide minimum 3. Tight butt joints on inner layer : 4 Minimum 3" overlap"on perimeter and between adjacent blanket on outside layer 5. Minimum 3/8"diameter hanger rod 6. Minimum 2"x 2" x 118" angle 7. Optimal 6" FastWrap XL collar Thermal Ceramics FireMaster FastWrap XL Typical Insulation Pin Layout For Duct Spans>24"Wide To Prevent Blanket Sag SIDE ELEVATION END ELEVATION -- - Figure 3 BOTTOM VIEW 6L1ni-ML—U—M 12 gauge steel insulation pins Thermal Ceramics FireMaster FastWrap XL Access Door Systems Commercial Kitchen'Grease Duct 2 FireMaster DuctMate FireMaster Field F2-HT Door System Fabricated Door System Figure 4 1. DuctMateD F2-HT Access Door or 16 5. Spool pieces gauge cover plate 2. All thread rods 6, Wing nuts and washers 3. installation pins with speed clips Outer cover plate I Three layers FastWrap XL with mini- 7. labeled "ACCESS 4. mum V overlaps and all edges sealed DOOR-DO NOT wtih aluminum tape OBSTRUCT" Thermal Ceramics FastWrap XL Through Penetration System I or 2 Hour Grease Duct 2 4 . SECTION A-A SECTION A-A N A A A A FLOOR VIEW FLOOR VIEW FastWrap XL F:5sf,.6.r-ap Xl. T-arn-il r,xe�.At The To P./-%nd Bottrim COPUIILIO-J�Through Figure 5 1 IDuct 2 Two layers FastWrap XL 3 Scrap pieces of FastWrap XL 4 Approved Through Penetration FireStop Sealant 5 Rated floor or wall North America-Sales Offices South America-Sales Offices Colombia Canada Argentina T+57(2)228293512282803/2282799 T+1(905)335 3414 T.+54(11)4373 4439 F;+54(11)4372 3331 F;+57(2)228293512282803123722085 F:+1(905)335 5145 Brazil Guatemala Mexico T r0(21)2418 1306 F; 55(21)2410 1206 T.+60(2)4733 20616 T.+52(555)576 6622 Chile F.,+50(2)4730 601 F:+52(555)576 3060 T+56(2)854 1064 F:+56(2)854 1952 Venezuela United States of America T+58(241)B78 3164 Eastem T.+1.800.338.9284 F,*1.866.785.2764 F:+58(241)878 6712 Western T-.+1.866.785.2738 F:+1.866.785.2760 04.0817 14-23616.OM ' SJ IREC ERVEnn U. ANSUL FUSIBLE LINK TEMPERATURE LE ION CT 1 6 2023 SYSTEM SHALL MEET SUFFOLK COUNTY FIRE a SHALL BE PER THE ANSUL INSTALLATION ES ELECTRICAL SHUT DOWN (IF REQUIRED)-BY OTHERS PREVENTION ORDINANCE, NFPA 17A (2017 ED), MANUAL RECOMMENDATIONS NFPA 96 (2017 ED), NFPA 10 (2018 ED), Buildin MU CONNECTION TO MAKE UP AIR FAN, SHUT DOWN UPON NYS BUILDING (2020), FIRE & MECHANICAL CODES g Department ACTIVATION(IF REQUIRED CONNECTION BY OTHERS) Town of SOLAhold CONNECTION TO HORN STROBE/AUDIBLE DEVICE OR ALL SYSTEM PIPING SHALL BE 11'-0'• A F.A.C.P. ACTIVATES UPON SYSTEM DISCHARGE (SUPPLIED&INSTALLED BY OTHERS) 3/8" BLACK SCHEDULE 40 I 18"DIA DUCT ALL ELECTRIC APPLIANCES - I I I . i 2W i I I I ________ __________ ------ ____ REGULATED RELEASE 360 360 60 368 450 (1) 3-GALLON TANK 101-20 CARTRIDGE 1N IN n I (LOCATED IN END CAP OF HOOD) I _ m I - ,FII— I 6"MI�J I �E-1F 1N IF MIN I OVERHANG 29 OVERHANG --�- 36 W 13-W I I , I I I ELECTRIC 42"-48" ° DISCONNECT ( (BY OTHERS) 2-BURNER PASTA PLAQUE 2-BURNER FRYER REMOTE PULL STATION RADIANT COOKER ANTHANOR RADIANT 16"x19" SHALL BE INSTALLED 42" - 48" ABOVE THE FINISHED 12"x24" 12"x16" COOK TOP 12"x24" FLOOR AT A DISTANCE OF NOT MORE THAN 20FT FROM 36"xl6" THE HOOD. IT SHALL BE INSTALLED IN THE PATH OF EGRESS AND REQUIRE A MAXIMUM FORCE OF 40 LBS i AND A MAXIMUM MOVEMENT OF 14" FOR ACTUATION ANSUL R102 - 3 GALLON SYSTEM TANK 1 USES: 9 of 11 POINTS SYSTEM PIPING LIMITATIONS SHAALLLL K WET CHEMICAL EXTINGUISHER SH BE INSTALLED NO MORE THAN 60" ABOVE THE NOZZLE SUMMARY TABLE 3GALLON(per cylinder) FINISHED FLOOR WITHIN 30 FT FROM THE HAZARD. HAZARD I QTY I NOZZLE I PTS TOTAL PRE-ENGINEERED SYSTEM SHOP DRAWING ONLY DUCT PLENUM APPLIANCE SCALE: 1/4" = 1'-0" TANK 1 - 3 GALLON TANK - 11 FLOW POINTS MAX z IF 1 2 REQUIREMENTS SUPPLY BRANCH BRANCH BRANCH INTERSTATE FIRE&SAFETY EQUIPMENT CO. INC. 2-BURNER PIPE SIZE 3/8" 3/8" 3/8" 3/8" 75 CALVERT STREET 1 IN 1 1 COOK TOP HARRISON, NV 10528 MAXIMUM LENGTH 40 FT 8 FT 4 FT 12 FT FRYER 1 290 2 2 THE SILVER SANDS MOTEL MAXIMUM RISE 6 FT 4 FT 2 FT 2 FT. 1400 SILVERMERE ROAD PLENUM 2 1N 1 2 MAX 90 ELBOWS 9 4 4 6.' GREENPORT, NY 11944 DUCT 1 2W 2 2 MAX TEES 1 1 2 2 4 r,(914),937-6100 is1IE Nus No NEv _ KITCHEN FINE SYSTEM 4 TOTAL 9_ MAX FLOW POINTS 11 1 4 2 4'' �'" it>E.. u NOTED 1 9/5/2e23 ISHEET 1 OF 3 PIPING ISOMETRIC - TANK #1 N . T. S 2W 12" 8„ 10.. y24' 24" 6" D25" 17" 25" 17" 22" BAG " E 12" 12" 1N A ANSuL 24" 36" 3-GAL 1F 1N 1F 290 ANSUL R102 - 3 GALLON SYSTEM TANK 1 USES: 9 of 11 POINTS TANK 1 — 11 POINTS MAX START END FT 1PIPE SIZE NOZZLE QTY FLOW PTS A TANKS 1 & 2 END OF SUPPLY LINE H 13.1 3/8" B SUPPLY LINE PLENUM NOZZLE 0.5 3/8" 1N 1 1 C SUPPLY LINE FRYER NOZZLE 4.0 3/8" 290 1 2 D SUPPLY LINE 2—BURNER NOZZLE 3.0 3/8" 1F 1 1 E SUPPLY LINE IDUCT NOZZLE 0.5 3/8" 2W 1 2 F SUPPLY LINE ICOOK TOP NOZZLE 3.0 3/8" 1N 1 1 G SUPPLY LINE 2-BURNER NOZZLE 3.0 3/8" 1F 1 1 H SUPPLY LINE PLENUM NOZZLE 0.5 3/8" 1N 1 1 - _ 27.( 7.0 9.0 � � - INTERSTATE FIRE 8 SAFETY EQUIPMENT CO. INC. 75 CALVERT STREET HARRISON, NY 10528 ALL PIPE LENGTHS ARE ESTIMATES BASED ON SKETCHES AND / OR ARCHITECTURAL DRAWINGS �: ,�� THE SILVER SANDS MOTEL FIELD CONDITIONS MAY REQUIRE ADJUSTMENT TO THESE PIPE LENGTHS / MEASUREMENTS ',,\'.7;'�.'� � .j. 1400 SILVERMERE ROAD GREENPORT, NY 11944 AT NO POINT SHALL THE TOTAL PIPE LENGTHS or PIPE VOLUMES BE ALLOWED TO EXCEED THE MAXIMUM LIMITATIONS 14 ,( Dus ND RV (9 zxzE INSTALLER SHALL ENSURE THAT ALL MINIMUM AND MAXIMUM PIPE LENGTHS, PIPE VOLUMES AND PIPE FITTING ALLOWANCES ARE MET AT TIME OF INSTALLATION _ «zTcxeN FIRE srsTEn a .a $CdIE AS NDTED 9/5/2023 SHEET 2 OF 3 J, _ i Ra ' Ra I I I I I I , a o I I I �- I �w I I nm ii it r--- � I I II /,j o I NNNiia,ie I I� ff I III rrri GGria I I bbid bb�J I L-I II FRZ r--- _ I I \ I I I REMOTE PULL o STATION w 1 — p p p ' id�Ni id�ia ANSUL 3-GALLON TANK & CONTROLS 'n INTERSTATE FIRE&SAFETY EQUIPMENT CO. INC. 75 CALVERT STREET ! J HARRISON, NY 10528 NOTE: PULL STATION IS LESS THAN 1OFT FROM THE SILVER SANDS MOTEL HAZARD BUT IS IN THE BEST LOCATION FOR FLOOR PLAN GREEPORTR NY19044 THIS KITCHEN AND ON THE PATH OF EGRESS NOT TO SCALE (914)937-6166 a! ENO _... K—NEN FIRE SYSTEM 4 ise as NOTED 9/5/2023 SNEET 3 OF 3 Why choose Interstate Fire ... 1 INTERSTATE FIRE&SAFF''� ll I tl TE FIRE&SAFC t + We are a pro-active , '(��Stp ` organization who puts �� RRONGUISHERS-STEAMCLEANING _ - life safety and the customer first WuPPRESSION SYSTEMS'-FIRE SPRINKLERS I 203.531.1333 SALES SERVICE 914 I �g + Over 60 plus years of ° -937-6100 ` ., ° but 1A 24 out dow, LIC#F30002 ' - fire protection experience ° + Knowledgeable / trained technicians with manufacturer and third party training + National certification in areas of fire protection, training ; and leadership r � w - + Code enforcement experience and ability to communicate 1 nasssa m./ _ with local authorities I When you think + Single source of ' fire protection, think fire protection needs I�) Interstate Fire + Consolidation in pricing — a leader in the + Hands-on training for fire protection industry your employees for your Interstate Fire & Safe ' fire protection equipment - since 1951! Equipment_Company;Inc. + Fire Extinguishers 75 Calvert St. . Harrison,NY 10528 J' + Fire Suppression Systems Mailing: PO Sox 4165, Greenwich CT 06831 + Hood & Duct Cleaning Phone: 914.937.6100 /203.531.1333 t safety, o Fax: 914.937.9723 ? + Fire Sprinklers c + Emergency Lights rYour our concern " Ve�n�t��l�a`tiron H �o'ds Restaurant Exhaust Hoods & Ventilation Hood & Fire Sprinkler Systems Fire Suppression Systems Duct Cleaning , Protect your restaurant J' ! Protection of your A properly t� . and your customers. 2Yj kitchen exhaust installed and Proper installation system is essential for maintained fire and maintenance of i/ e j its proper operation sprinkler system can your fire protection f/� and the safety of save lives and lower insurance costs. systems will ensure your restaurant workers At Interstate Fire &Safety our licensed that you do just that! and patrons. That is and insured sprinkler installation and why at Interstate Fire &Safety,we have service technicians will ensure that your Our installers have received training from developed an all inclusive steam cleaning systems function properly.We provide industry experts in fire protection systems program, complying with the applicable system maintenance and inspections to such as Captive Aire, Pyro Chem and section of the N.F.P.A.96 Fire Code and mitigate the possibility of a system failure. Buckeye to ensure we provide our customers ANSI C-10 standard,that is specific to each This pro-active approach assures that with the best service possible from start restaurant's needs.Our technicians will also your system will have low long term to finish. photograph your job site before and after maintenance costs. completion of the work(as requested by the Restaurant cooking equipment emissions customer). Our technicians can install Fire Extinguishers are generally contaminated with vaporized access doors, exhaust fan hinge kits and grease and other fuels that can ignite a grease collection systems. potential fire. _ Fire extinguishers L are important Emergency Lights - life safety We will conduct _ - < T�Ur) r a complete survey � Emergency lights provide ��I a devices that ` are our first of your site and lighting in corridors, stairwells, y design a system `' o`` ramps, escalators, aisles, and exit line of defense �- co> in case of fire. best suited for passageways in the event of a power outage. your fire protection needs. , If your emergency lghts-fail-to-operate-� Whether you have a sprinkler system, properly during an emergency situation wi ater-standpipe-and-hose-setup;'everyr i the building occupants may become facility is required to have extinguishers We also conduct system inspections, al maintenance and service on all makes and disoriented. Our trained technicians will that are properly maintained.Not only do models of fire systems. perform the required testing and maintenance we sell fire extinguishers but we also service on emergency lights and provide you with . all major brands with state of the art hydrostatic the written records as required by law. testing and recharging equipment. 2��hk�a�:��a��ka.�r:�+�����-�:i..�'�Itli` �fL� t .fir _ � a"G�,..,-_ .�,^ i �;ka5:. •.+s' c� � _d_ -.9, kw MM I fiortn / tion and Pricing 914.9i iffil-M 11FAIrr FIRS' INSPECTION REQUIRED BEFORE OPENING D� FUSIBLE LINK TEMPERATURE SELECTION SYSTEM SHALL MEET SUFFOLK COUNTY FIRE H. ANSUL SHALL BE PER THE ANSUL INSTALLATION ES ELECTRICAL SHUT DOWN (IF REQUIRED) - BY OTHERS PREVENTION ORDINANCE, NFPA 17A (2017 ED), MANUAL RECOMMENDATIONS NFPA 96 (2017 ED), NFPA 10 (2018 ED), CONNECTION TO MAKE UP AIR FAN, SHUT Da.,N UPON NYS BUILDING (2020), FIRE & MECHANICAL CODES ACTIVATION (IF REQUIRED CONNECTION BY OTHERS) CONNECTION TO HORN STROBE / AUDIBLE DEVICE OR _ 11'-0" F.A.C.P. ACTIVATES UPON SYSTEM DISCHARGE ALL SYSTEM PIPING SHALL BE a "�-+ (SUPPLIED & INSTALLED BY OTHERS) 3/8" BLACK SCHEDULE 40 I 18" DIA - APPROVED A NOTED q, / 3 4� ALL ELECTRIC APPLIANCES Ducr i DATE" B•P I 2W ' FEE: Z5 BY: NOTIFY BUILDING D PA TMENT AT -------- ---------- ------------------- ------ ---- - I REGULATED RELEASE 765-1802 9 AM TO PM FOR THE 366 360 3 0 366 456 (1) 3-GALLON TANK FOLLOWING INSPECTI NS: 101-20 CARTRIDGE 1. FOUNDATION - NA REQUIRED 1N 1N m I (LOCATED IN END CAP OF HOOD) FOR POUPE,D CONC 'ETE ----- ----- -- - -- -------- - ------- ----- 1 ' 2. ROUGH - FRAIVII & PLUMBING 3. INSULATION J 1F IN It6l. i 4, FINAL - CONST UCTION MUST OVERHANG 7 1F 290 1 OVERHANG ; BE COMPLETE FO C.O. 3S•40• ALL CONSTRUCTIO SHALL MEET 4°--48- 33--16' I THE REQUIREMEN S OF THE N.Y. STATE CONSTRUC ION & ENERGY CODES. NOT RES ONSIBLE FOR DESIGN OR CONTT CTiON ERRORS I r I ELECTRIC 42"-48"° DISCONNECT Additional tonal - - I (BY OTHERS) May 2-BURNER PASTA PLAQUE- 2-BURNER FRYER REMOTE PULL STATION May Be Required. RADIANT COOKER ANTHANOR RADIANT 16"x19" SHALL BE INSTALLED 42" - 48" ABOVE THE FINISHED �y 12"x24" 12"x16' COOK TOP 12"x24"xi FLOOR AT A DISTANCE OF NOT MORE THAN 20FT FROM �`�� j �Y 1 �� 36" 6" ®THE HOOD. IT SHALL BE INSTALLED IN THE PATH OF EGRESS AND REQUIRE A MAXIMUM FORCE OF 40 LBS ANSUL R102 3 GALLON SYSTEM Jn���yyy AND A MAXIMUM MOVEMENT OF 14" FOR ACTUATION r, - p - � '�♦ TANK 1 USES: 9 of 11 POINTS SYSTEM PIPING LIMITATIONS CLASS K WET CHEMICAL EXTINGUISHER - SHALL BE INSTALLED NO MORE THAN 60" ABOVE THE 3 GALLON (per cylinder) FINISHED FLOOR WITHIN 30 FT FROM THE HAZARD. IL/p'� NOZZLE SUMMARY TABLE (P Y � ) (,/ HAZARD I QTY NOZZLE I PTS TOTAL PRE-ENGINEERED SYSTEM SHOP DRAWING ONLY'-0"4"1/ = 1 - TANK 1 - 3 GALLON TANK - 11 FLOW POINTS MAX DUCT PLENUM APPLIANCE SCALE: , __ __-. z iF 1 2 REQUIREMENTS SUPPLY BRANCH BRANCH PIPE SIZE 3/8 BRANCH INTERSTATE FIRE & SAFETY EQUIPMENT CO. INC. �rv/�1lYe/► e 2-BURNER „ 3/8 n 3/8 n 3/8 u 75 CALVERT STREET SHALLCOOK TOP 1 1N 1 1 HARRISON, NY 10528 ME- T FRYER 1 290 2 2 IEREQUIREM�NTSOFTEi MAXIMUM LENGTH 40 FT 8 FT 4 FT 12 FT T I L INES OF NEW YnRK STATF MAXIMUM RISE 6 FT 4 FT 2 FT 2 FT `" 1400SILVERMERE ROAD PLENUM 2 1N 1 2 MAX 90 ELBOWS 9 4 4 6 GREENPORT, NY 11944 DUCT 1 2W 2 2 MAX TEES 1 2 2 4 (914) 937-6108 SIZE owc xo m� REV KITCHEN FIRE SYSTEM 4 TOTAL 9 MAX FLOW POINTS 11 4 2 4 '�'" - SCALE AS NOTED 9/S/2023 SHFET 1 OF 3 PIPING ISOMETRIC TANK #1 N . T . S 2W APPROVED S NOTED H 21" 25- 17"�6" 25" 17" 22" DATE:-�B A FEE: - NOTIFY BUILDING EPARTE. &12" 121. E 12 12 6 765-1802 9 AM T 4 PM F IN IN r2ll,.2r SP ONS: )u.0WING IN - IJNDATION - TWO -POURED CORETr 2 4"r2 14 24" 36" FRAM NG I INSULATION 3-GAL 4. FINAL - CONS RUC' IF IN I F 13E COMPLETE F R C-'. ALL CONSTRUCT ON v 290 THE REQUIREME -3-TATE CONSTR NOT R ANSUL R102 - 3 GALLON SYSTEM jGN OR CONS TANK I USES: 9 of 11 POINTS TANK I — 11 POINTS MAX START END FT PIPE SIZE NOZZLE QTY FLOW PTS A TANKS I & 2 END OF SUPPLY LINE H 13.1 3/8" B SUPPLY LINE PLENUM NOZZLE 0.5 3/8" IN 1 1 c SUPPLY LINE FRYER NOZZLE 4.0 3/8- 290 1 2 D SUPPLY LINE 2—BURNER NOZZLE 3.0 3/8" IF 1 1 E ISUPPLY LINE DUCT NOZZLE 0.5 3/8" 2W 1 2 F ISUPPLY LINE COOK TOP NOZZLE 3.0 3/8" IN 1 1 G SUPPLY LINE 2—BURNER NOZZLE 3.0 3/8" IF 1 1 H _SUPPLY LINE PLENUM NOZZLE 0.5 3/8" IN 1 1 INTERSTATE FIRE & SAFETY EQUIPMENT CO. INC. 27.6 1 1 7.0 9.0 75 CALVERT STREET HARRISON, NY 10528 ALL PIPE LENGTHS ARE ESTIMATES BASED ON SKETCHES AND OR ARCHITECTURAL DRAWINGS THE SILVER SANDS MOTEL FIELD CONDITIONS MAY REQUIRE ADJUSTMENT TO THESE PIPE LENGTHS / MEASUREMENTS 1400 SILVERIMERE ROAD GREENPORT, NY 21944 AT NO POINT SHALL THE TOTAL PIPE LENGTHS or PIPE VOLUMES BE ALLOWED TO EXCEED THE MAXIMUM LIMITATIONS DWGNo SIZE DWG REV INSTALLER SHALL ENSURE THAT ALL MINIMUM AND MAXIMUM PIPE LENGTHS, PIPE VOLUMES AND PIPE FITTING ALLOWANCES ARE MET AT TIME OF INSTALLATION .(914) 9�7-61N KITCHEN FIRE SYSTEM 4 2 OF 3 SCALE AS NOTED 9/S/2023 IET i I IAPP OVED AS NOTE 1 n i I DATE: B.R# FEE: BY: r---------------- NOTIFY BUI DING DEP AT I I m ' --- � 765-1802 9 M TO 4 CIE FOLLOWING SPECTIr 1 FOLINDA ION - 7 q ---- E POUR D CORD' I ROUGH - FRAM _ 3. INSULATI N ----��i j 4. FINAL - ON`' MUST , I BE COMP ETEuj rr I I.: o m 1 =1 I ALL CONS UC= MEET r;l 0 - I L--�'I THE REQUI EI'. E N.Y. i 6 ---- 1 I zs STATE CO TF .NERGY I I w II9 1 I CODES. N T ,. ,TF FOR I I u; r1 i i 1 I DESIGN OR00 4=, ERRORS - ,4;1;1 rrri FRZ L_-- \ �---- ,I 0 1 REMOTE PULL STATION W i h;rt;i i;rrt `! 7ANSUL 3-GALLON TANK & CONTROLS INTERSTATE FIRE & SAFETY EQUIPMENT CO. INC. 75 CALVERT STREET HARRISON, NY 10528 NOTE : PULL STATION IS LESS THAN 1OFT FROM THE SILVER SANDS MOTEL HAZARD BUT IS IN THE BEST LOCATION FOR FLOOR PLAN 140E SILVERMERE ROAD � GREENPORT, NY 11944 THIS KITCHEN AND ON THE PATH OF EGRESS NOT TO SCALE SIZE DWG NO pJG REV ..CHEII FIRE SYSTEM 4 SCALE AS NOTED 1 9/5/2023 SHEET 3 OF 3 FUSIBLE LINK- TEMPERATURE SELECTION : : ��" ANSUL� SHALL BE PER THE ANSUL INSTALLATION.: ELECTRICAL SHUT oowN (IF REQUIRED) - BY OTHERS: MANUAL RECdMMENDATI0N5 E5 ( CTION CO NNECTION.TO MAKE UP AIR FAN, SHUT.DOWN UPON ACTZVATION IF REQUIRED:CONNE BY OTHERS) . Y NNECTION TO-HOR BE , A E STRO UDIBLE DEVICE OR F. C ACTIVATES UPON N i ALL SYSTEM PIPING SHALL BE 11'�"Q COSYSTEM,DISCHARGE (SUPPLIED & INSTALLED BY OTHERS) 3/8" BLACK SCHEDULE 40 t . - 12" DIA t DUCT. _ . I ALL ELECTRIC APPLIANCES. . t 1w I EG LATED RE EASE i 36e 60 60;, 360 4SO (1)U3-GALLONLTANK PO _ - . 101-20 CART N� C)� 1N iN m t (LOCATED IN END CAP OF;HOOD) cc .. :. - .. % .. .. - .. ... ... -- .. . . .. �_ .. .. 1N iF 1F:. t :48 22' 290 i R�fiE IS? P� t t .. .. _ .. i ; ELECTRIC 427-48"' � DISCONNECT - - -- - —- - (BY 6THER5) : . .... 2-BURNER; PASTA PLAQUE 2-BURNER :FRYER RADIANT_ COOKER ANTHANOR RADIANT '16"x19" REMOTE PULL STATION - . 12"x24" 12"x16" COOK TOP. 12"x24" SHALL BE INSTALLED 42 - 48 ABOVE THE FINISHED ANSUL R102 — 35".xi6'' 3 :GALLON SYSTEM FLOOR AT A DISTANCE_ OF NOT MORE TH N OF FR THE HOOD. IT SHALL BE INSTA LED I T E ATH OF OM TANK-1: US-ES.: 8 Of 11: POINTS: . . . EGRESS AND REQUIRELA:MAXIMUM LFORCE NOFH40PLB5., " AND A MAXIMUM MOVEMENT OF 14" FOR ACTUATION---, NOZZLE SUMMARY TABLE SYSTEM PIPING LIMITATIONS CLASS K WET CHEMICAL EXTINGUISHER- HAZARD SHALL BE INSTALLED NO MORE THAN 0" ABOVE THE QTY NOZZLE PTS TOTAL 3 GALLON-(per c linden - �P Y � WISHED FLOOR'WITHIN 30.FT FROM THEHAZARD.- . .... F. TANKS 1 & 2 - 2) 3 GALLON TANKS - 22 FLOW POINTS MAX _" . - 1F z RE ENGINEAR M SHP._D0 R„AWI . ONLY 2-BURNER: Z SCALE: 1/4" 1 i IN.. . 1 1. . REQU.IREMENTS SUPPLY BRANCH. BRANCH:- ' BRANCH.. COOK TOP: _... ... INTERSTATE FIRE:& SAFETY EQUIPMENT CO.: INC.' FRYER i 29e 2: 2 PIPE SIZE 3 8". 3 8" 3 8" 3 811 75•CALVERT STREET - -'HARRISON, NY.10528 ... 2 iN:. ::z MAXIMUM LENGTH 40 FT $'FT:':. 4 FT ': 12 FT PLENUM HARK " HE SILVER SANDS MOTE ..DUCT . x iw.. . i 1. MAXIMUM RISE .6 FT 4.FT..... . 2 FT 2 FT T L ' 1400 SILVERMERE ROAD TOTAL 6 MAX 90 ELBOWS 9: . 4 4 6: GREENPORT; NY 11944 .. ... ". .. .. .. .. ... .. ... -- NO � � REV - .. MAX TEES 1 2: :. 2 4 (9ia) 937 6100 .. .. .. .. �. ..SIZE DWG D . .. FIRE:SYSTEM 1 . ... .: - .: ... .. .: :.: .. . .. SCALE AS NOTED' ':3�24/2023 SHEET .. 2 OF 7 MAX;FLOW.POINTS 11 4 .- .. - 2 4 PIPINGISOMETRIC- -- TANK 1 N . T . S r 1W 12'� H G F tV . p. . . C 8[[ 10" 21": . 25" -17" 25" 17 22" B: A 6" 6.. 1N 1N . 8 ANSUL. 24' 24' 24'' . 36" 3-GAL 1F . . .1N 1F: 250. ANSUL. R102 - 3 GALLON SYSTEM TANK 1 — 1'1 POINTS MAX TANK 1 USES: 8 of 11 POINTS START - END-: F3' PIPE SIZE :NOZZLE QTY:.: FLOW PTS A TANKS 1 & 2: END OF SUPPLY. LINE H 13.1 3/8?'- - - - B SUPPLY PLENUM NOZZLE 0:.5..-..- 3:/8" 1N:.: C SUP,PLY, LINE FRYER NOZZLE 4.0 ... .318" 290 .. �1 2' ... .. D SUPPLY LINE.;-; 2—BURNER NOZZLE 3.0 3/8';..: 1F 1 . : 1 N F.• _ SUPPLY LINE. DUCT NOZZLE':_ 0.5 3/8.': 1W 1:: 1 ��pf.M E 1. . F SUPPLY' LINE COOK TOP NOZZLE 3..0.. . ...:318" 1N .. ::I 1. .. 0 G2O��: G SUPPLY, LINE 2cBURNER NOZZLE 3.0. 3/8" 1F H SUPPLY LINE.:.: PLENUM NOZZLE : 0.5 3/8":_ 1N 1:...: 1 0 27.6 7:0 8.0 842Z wo w. OFESSI�P�. INTERSTATE:FIRE:&'SAFETY EQUIPMENT CO.. INC: 75 CALVERT STREET SON, NY 10528 ALL PIPE LENGTHS; ARE ESTIMATES BASED ON SKETCHES AND_/ OR•ARCHITECTURAL DRAWINGS FIELD: CONDITIONS MAY.RE UIRE-ADJUSTMENT TO:THESE PIPE LENGTHS.: MEASUREMENTS Q . R THE SILVER SANDS MOTEL 1400 SILVERMERE'ROAD' GREENPO T, NY 11944 AT NO. POINT SHALL THE:TOTAL PIPE LENGTHS or PIPE VOLUMES BE ALLOWE0.TO EXCEED THE MAXIMUM LIMITATIONS ..... .. .- ... ..-. .. ... .. ..... ... .. .. ... 0 INSTALLER SHALL ENSURE THAT ALL MINIMUM AND MAXIMUM PIPE LENGTHS, PIPE VOLUMES AND PIPE FITTING:ALLOWANCES ARE MET AT TIME OF INSTALLATION (9 14) 937 6100 siz_ _ E DNG �� DNG. FIRESYSTEH 1 SCALE AS NDTED- 3/14/2023 SNEET 3 OF:7.- : 7, ��OF NEW- . r . . p � � NY 4n �. AR 48422 OfiESSW I r � I i to f . I r-- i�i�%� - - -- I , o I __-- Gn _ �I I I r I LL t I I = I w \ jim = L: 1J � I. I I Of LL LLI t iildiiiii I W - O t \ FRZ ---I REMOTE PULL._ I'. STATION -- is I. ANSUL 3—GALLON .TANK &- CONTROLS INTERSTATE:FIRE &SAFETY EQUIPMENT CO. INC. • 75'CALVERT STREET NOTE . PULL STATION IS LESS THAN 10FT FROM HARMON, NY 10528 HAZARD BUT IS IN THE BEST LOCATION FOR . . .. HE SILVER SANDS MOTE T1400 5ILVERMERE ROAD L THIS KITCHEN: AND ON : THE PATH OF EGRESS FLOOR - PLAN GREENPORT, NY 11944 T TO SCALE SIIE OIJG NO OWG (914) 937-6100 . FIRE SYSTEM 1 ' .. SCALE AS NOTED: 3/14/2023 SHEET 4 OF:7" INSTAUILINC r-rnr_ ABT DESIGN& FIRE PROTECTION 1724 CHURCH STREET HOLBROOK, NY,1 1741 ] 631-878-4896UFA -8l85727�_ 40 /96UCOTNASSAN 2 SUFFOLK COU Y C#1!/,j U $ 2�2 HUNTINGTONu APPROVED AS NOTED r , 'A Y R EMAIL:ABTFIRE@YAHOO. ll,"' U1l�OMO FRONT VIEW SIDE VIEW DATE g��f�Z3 B•P # 7 �6 USE IS U��L/'�'Y `—FUL ®�A� 1/4"®®S: '/a"SCALE ' " SCALE FEE: Z-'50 �� WITHOUT CERTIFICATE SILVER SANDS NOTIFY BUILDING DEP.ARTMENY AT rOCCUPANCY 1400 SILVERMERE RD BUILDING HAS 765-1802 8 AM TO 4 PM FOR THE GREENPORT, NY 11944 FOLLOWING !NSPECTIOrvS FIRE ALARM 1. FOUNDATION - TWO REC:UIRED FIRE SPRINKLER SYSTEM FOR POURED CONCRETE 2. ROUGH-FRAMING PLUMBING. ELECTRICAL DRAW BY: ANDREA BAYARD ON 03/17/2023 STRAPPING. ELECTRICAL& CAULKING INSPECTION REQUIRED ANDREA BAYARD-REVISION#1-05/04/2023 3 INSULATION 4 FINAL-CONSTRUCTION & ELECTRICAL MUST BE COMPLETE FOR C.O.KITCHEN x All Views to the following scale T�4 Dimensions ALL CONSTRUCTION SHALL MEET THE ,- RG INSPECTION x New Kitchen _Existing Kitchen REQUIREMENTS OF THE CODES OF NEW ARE ��®�� NON Combustible[Masonry] _Limited Combustible-[S/Rock-Metal Stud]] _Combustibles YORK STATE. NOT RESPONSIBLE FOR R G uG�UIED B x FIRE RATED WALLS-2 hr _Exiting-1 HR OK _Special Sprinkler Instillation-1 hr ok DESIGN OR CONSTRUCTION ERRORS. t x OPENING PROTECTIVE[1 T/2 hr]-[self closing,latching,fire rated door assembly] Special Sprinkler Instillation%%hr ok OPENI�� OR _OK WITHOUT Opening Protective's if ALL the following comply: 10'MIN TO ANY AIR 10'MIN TO ANY AIR *Draft Curtain 24"ht[NC/LC] *Hds/Aes *Special Sprinkler Installation — INTAKE INTAKE PLEASE SEE Exit at Grade---or---Sprinkler heads within 24 inches of draft curtain,60 inches apart,kitchen side ELECTRICAL NOTES DAYTON K DAYTON Cooking Equipment in the kitchen Cooking Equipment at the front counter_Cooking Equipment in the dining room AT BOTTOM OF PAG MODEL#7A623 a GREASE COLLECTOR BOX MODEL#7A631 2750 CFM 4800 CFM _Cooking Equipment in a mobil unit_Cooking Equipment in a concession stand_Pizza Oven MAKE UP AIR l -I .$ ® ,,J!I;'.' .i I�.. �I PAL!- DAYTON � HOOD U/�il,►�/ MODEL#7D496 12oVS R I 5!Gl. '.�� a $'l �lI.��I:r'.`�.'°(."1 ; C Sr` I{ 1950 CFM o ors tV D _Exhaust cfm-Medium Duty •Exhaust cfm-Heavy Duty _Exhaust cfm-Extra Heavy Duty y boo , D '��sr YIh.; ' �.;•-, I -r '1- [hot top,griddle,fryers,pizza,rotisseries] [range,wok,gas/elec broilers] [Solid fuel char broilers] [Wall-Linear Ft x 3001[S-island Linear Ft x 5001 [Wall-Linear Ft x 400][S-island Linear Ft x 600] [Wall-Linear Ft x 550][S-island Linear x 700] RIDGE HEIGHT RIDGE HEIGHT X Liquid tight external weld x 12 ft max hood length per exhaust riser x 18 ga Stainless 13'0" 13'0" 18"ROUND X Supply Air 100%approx replacement _Supply air deg difference except A/C_Supply air hood damper(286 deg max) WELDED DUCT ROOD✓OIsr _Clearance-3"to Combustibles,including 1 inch mineral wool,(insulate the combustible not the hood) R Da •Clearance-3"to Limited Combustible _Clearance-0"to Non Combustible X Insulation-max Flame Spread Rating 25/x 18"ROUND CHARBROILERS-4'min to hood _Solid fuel to have spark arrestors _Solid fuel-under separate hood WELDED DUCT FIREMASTER XL x FRYER-16-inch space to the flame producing appliance or 16 inch high steel baffle F'-CLEARANCE AP N FILTERS to heat source 18-inch minimum To flue baffles 6 inch minimum(uprights,rotisseries,ovens,etc FOR 0 CLEARANCE TO _� .�_ ) COMBUSTIBLES •6 inch overhang all sides x 7ft maximum off floor x 24 inch minimum height all sides FIREMASTER xLISTED HOOD installed in accordance with terms of its listing. x Elec.Wire in conduit or EMT THERMOLOUPLINGTURNS FASTWRAP XL DUCT CAPTIVE AIRE Manufacturer 2750Exhaust x Clearance(Hood bottom to appliance top) FAN ONUPONSENSING DUCT FOR D"-CLEARENCETO OPENING 80 DEGREES COMBUSTIBLES sND-2-PSp-LModel 1950 Supply cfm _Maximum cooking surface temp LOCATED IN CAP TURE AREA OF HOOD NOT OPENING 18"ROUND WITHIN 6-OF ANY EDGE 18"ROUND DUCTS FAN ALSO HAS MANUAL SWITCH X AIRFLOW of 1500 ft/minute minimum 7-Dimensions(L x W x H) 1e"RouriD x 16 ga steel X Field welds to be Bell or Telescoping PSP X Duct exits bldg directly as possible x Horizontal duct travel less than 75' Duct connections to have flush bottoms m A 3'STANDOFF X Liquid tight external weld X No exhaust dampers use X Duct pitched back hood to collect grease xDucts not shared by others systems xShall not pass thru firewalls x Not insulated until inspected 11'x 54"x 18"FRONT/24"REAR _CLEARANCE-3"minimum from combustibles,including 1-inch mineral wool,(insulate the combustible not the duct) X Clearance-3"to Limited Combustible _Clearance-0"to Non Combustible GREASE COLLECTOR BOX X ACCESS PANELS-to be unobstructed _Within 3 ft each side of an inline fan X Signs-'Access panel-Do Not Obstruct' STAINLESS STEEL _20 Feet Horizontally _At every floor Vertically At every direction change ((� WALL COVERING _Access door at vertical riser base •Duct Secured to bldg x EXTERIOR-Weatherproofed b _ENCLOSURES in building more than 1 floor ceiling above hood or through any concealed spaces ducts shall be enclosed l �I *Penetrating floors&ceilings *6 inches between duct&enclosure *vented at roof _Though Penetration Fire Stop System as alternative to enclosures with 6"airspace shall have a minimum 3"inclusive airspace, f APPLIANCE FAN depending on mfg. LINE ATHANOR E-SUITE COOKING APPLIANCE 1p X TERMINATES-at building exterior up and away from roof X 40 inches from roof(See Drawing&Notes) x Fan hinges away from duct,with hold open retainer&flexible waterproof cable X Grease drains back to trap at fan •Minimum 10'to air intakes,property lines,windows,doors or 3"vertical x Safe access area for servicing —Non-Combustible side fan termination ok,no openings 10'horizontal vertical down,32'vertical up,except char-broilers not permitted NOTES FLOOR PLAN ELECTRICAL CONDUIT MUST RUN THROUGH CURB& BETWEEN ROOF& ENCLOSURE ELECTRIC RUN FROM CURB TO FAN TO BE DONE WITH SEALTIGHT CABLE AND MUST -- LEAVE ENOUGH SLACK TO ALLOW FAN TO HINGE BACK FOR DUCT CLEANING EXHAUST FAN AND RETURN AIR FAN TO BE ELECTRICALLY INTERLOCKED d CVI dd�,1 Q, m 00 n fig ` ELECTRICAL DONE BY OTHERS 1 / t M c•, m -This installation is in accordance with the Mechanical Code of New York State, Fire code of NYS, applicable codes of the Town of Southold and NFPA. LLJ �'- r"'� h II t 1 O CODE REFERENCES �c`�4 G�'A� THIS INSTALLATION IS IN CONFORMANCE WITH •. -NFPA 96-2017 ` -NYS MECHANICAL CODE 506,507,508 -ASTM E2336-2016 jORp ,gP°° -THE BUILDING AND FIRE CODES OF NEW YORK STATE-2020 N O1 _ i L. � r i;--- •Q t " I t 1 1 ^� N i •- = W'as, t l ' j Ai i i i i"{^ � �,,,�< 1 1 M • O rrr Tr1 w� 1 I �•--- to ^•�. FTRZ � t J ' L rl. ,rr 1� oc 1 r Visser III, Fredric To: Jerry Kouveras;Alexander Perros;William iBarnes Cc: Ryan Hardy;John LoBianco Subject: RE: Silver Sands RE: Interstate Fire Hello all, Plans all look good to me, please come early tomorrow morning the building department opens at 8:00 please bring your 3 stamped copies of the plans one will be returned to you stamped and approved to keep on the jobsite.Also please bring a copy of your Ansul manufacturl's certificate as well as your Suffolk County FELB certificate.As a reminder -working without a permit is illegal,working prior to the amendment to the-permit can and will result in stop work orders and double fees. I look forward to meeting with you tomorrow,once you are finished with the install and ready for compliance testing please call the office at 631-765-1802 to set an appointment. I know the hood and duct company is not in the email but they too also need there tests to be complete before I can recommend an "okay"for C/O to the Building inspector. Thank you all, Fredric Visser, Fire Marshal Town of Southold Phone: (631)765-1802 Web: https:Hsoutholdtownny.gov/1736/Fire-Marshal Email: Fredv@southoldtownny.gov PO Box 1179 54375 Main Road Southold, NY. 11971 From:Jerry Kouveras<jkouveras@samtell.com> Sent:Thursday,September 7, 2023 9:14 AM To:Alexander Perros<alex@dhgnyc.com>;Visser III, Fredric<fredv@southoldtownny.gov>;William Barnes <william.barnes@interstatefireandsfty.net> Cc: Ryan Hardy<ryan@dhgnyc.com>;John LoBianco<JLoBianco@Samtell:com> Subject: [SPAM]- RE:Silver Sands RE: Interstate Fire Importance: High @William Barnes—I just spoke with Fire Marshall Visser and if he gets the new 3-page Ansul system submission today stamped by your engineer he will review and "pre-approve" but it is imperative that you or your tech stop by the Township building tomorrow with three hard copies that are stamped for his files and records.All work can proceed tomorrow as long as you get the stamped copy to him by email today. Jerry Kouveras tell , Vice President of Design & Engineering The Sam Tell anies 36 E 31st Street,6 hpFloor, New York, NY, 10016 companies F: (212) 244-0057 C: (917) 642-9379 O ® c� 0 1 1 NOTICE:This electronic mail message and any files transmitted with it are intended ex,iusively for the individual or entity to which it is addressed.The message,together vvilh any attachment, may contain confidential and/or privileged inforrnation. Any unauthorized review, use, printing,saving, copying, disclosure or distribution is strictly prohibited.If you have received this message in error,please immediately advise the sencler by reply email and delete all copies. From:Jerry Kouveras Sent:Thursday,September 7, 2023 8:53 AM To:Alexander Perros<alex@dhenvc.com>; Fredric Visser(Fredv@southoldtownny.gov)<Fredv@southoldtownny.gov> Cc:William Barnes<will lam.barnes@ interstatefireandsfty.net>; Ryan Hardy<rvan@dhgnyc.com>;John LoBianco <JLoBianco@Samtell.com> Subject: RE: Silver Sands RE: Interstate Fire Resending this email as Fred's email address was incorrect. From:Alexander Perros<alex@dhgnyc.com> Sent:Thursday,September 7, 2023 8:35 AM To:Jerry Kouveras.<Kouveras@samtell.com>;fred@southoldtownny.gov Cc:William Barnes<william.barnes@interstatefireandsftv.net>; Ryan Hardy<rvan@dhgnvc.com>;John LoBianco <JLoBianco@Samtell.com> Subject: Re:Silver Sands RE: Interstate Fire Ll L1 Fred, bubbling this back to the top of your inbox. On Sep 6, 2023, at 5:20 PM,Jerry Kouveras<iouveras@samtell.com>wrote: Thank you for that update Alex. For what it is worth, I tried Fred's cell number that you gave me and the call would not go through. I left a message for the engineer as well to push him to stamp the drawing set tomorrow and I will follow up with him again tomorrow. Jerry Kouveras Vice President of Design & Engineering The Sam Tell Companies 36 E 31st Street, 6th Floor, New York, NY, 10016 F: (212)244-0057 C: (917) 642-9379 sam tell , com n ies 2 I 3 4 l 5 CP O ' NOTICE:This electronic mail message and anyfiles transmitted with it are intended exclusively for the individual or entity to which it is add rLssed.The message,toget with any attachment, may contain confidential and/or privileged information. Any unauthorized review, use, printing, saving, copying, disclosure or distributio strictly prohibited.If you have received this message in error,please immediately advise the sender by reply email and delete all copies. From:Alexander Perros<alex@dhgnyc.com> Sent:Wednesday,September 6, 2023 5:18 PM To:William Barnes<William.barnes@interstatefireandsftv.net> Cc:Jerry Kouveras<iouveras@samtell.com>;fred@southoldtownny.gov; Ryan Hardy <rvan@dhenyc.com>;John LoBianco<JLoBianco@Samtell.com> Subject: Re:Silver Sands RE: Interstate Fire I!l I!\ 01 6 Fred sent me a text message and will be checking the email first thing tomorrow morning. He left around noon today so I wasn't able to get to it. William, if in fact everything is in order,please plan to be on site on Friday when we have scheduled the other trades. Thanks and hopefully we will know more tomorrow and can put this to bed once and for all. On Sep 6, 2023, at 3:41 PM, William Barnes <william.bamesninterstatefireands . .net>wrote: Jerry—914-769-0700 William Barnes Jr. President Interstate Fire &Safety Office 914-937-6100 Office 203-531-1333 Fax 914-937-9723 Serving the Fire Protection Industry since 1951—please visit https://interstatefireandsftv.net/ifs-slideshow on our core values on customer service /life safety This e-mail (and any attachments) may contain proprietary and/or confidential information, and is intended for the individual or entity named above as recipient. It is intended for informational purposes only and does not constitute legal advice. The Information contained in this message may be privileged, confidential and protected from disclosure. If the reader of this message is not the intended recipient,or an employee or agent responsible for delivering this message to the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please notify the sender immediately and delete this message for your computer. From:Jerry Kouveras<jkouveras@samtell.com> Sent:Wednesday,September 6, 2023 1:22 PM To:Alexander Perros<alex@dhgnyc.com>;fred@southoldtownny.gov Cc:William Barnes<william.barnes@interstatefireandsftv.net>; Ryan Hardy <rvan@dhgnyc.com>;John LoBianco<JLoBianco@Samtell.com> Subject: RE:Silver Sands RE: Interstate Fire Alex—I tried Fire Marshal Fred Visser on the cell number and kept getting an error message. Left a VM at the Building Department as he is out of the office for the day doing site visits. I am adding Fire Marshall Visser to this email in the hopes we can expedite the completion of the system. @fred@southoldtownny.gov—Interstate Fire is pushing their mechanical engineer to sign off the drawings today....tomorrow at the latest.'Willaim Barnes of Interstate has noted that he has updated his drawings based on your comments.See attached. Is it possible or you to confirm that all is in order based on the attached PDF?The goal is to get Interstate to the site this Friday the 8th to complete and test the Ansul system. Can they proceed with scheduling the completion of the work? Please advise and thank you in advance for your consideration with this matter. 7 Regards. Jerry Kouveras Vice President of Design & Engineering The Sam Tell Companies 36 E 31st Street, 6th Floor, New York, NY, 10016 F: (212) 244-0057 C: (917) 642-9379 NOTICE:This electronic mail message and any files transmitted with it are intended exclusively For the individual or entity to which it is addressed.The me., with any attachment, may contain confidential and;cr privileged information. Any unauthorized review, use, printing, saving, copying, disclosure or strictly prohibited.If you have received this message in error,please imrnediately advise the sender by reply email and delete all copies. From:Alexander Perros<alex@dhgnyc.com> Sent:Wednesday,September 6, 2023 9:50 AM To:Jerry Kouveras<ikouveras@samtell.com> Cc:William Barnes<william.barnes@interstatefireandsfty.net>; Ryan Hardy <rvan@dhgnvc.com>;John LoBianco<JLoBianco@Samtell.com> Subject: Re:Silver Sands RE: Interstate Fire I!l Ll This is bonkers. Seriously guys. Here is his info and direct mobile. Also you can call Building Dept and ask for him. (631) 765-1802 @s <image016.png> On Sep 6, 2023, at 9:29 AM, Jerry Kouveras <jkouveras@samtell.com>wrote: @Alexander Perros—did the FM give you contact info?You think we could get him to commit to a Teams call today? Jerry Kouveras Vice President of Design & Engineering The Sam Tell Companies 36 E 31st Street, 6th Floor, New York, NY, 10016 8 F: (212) 244-0057 C: (917) 642-9379 NOTICE:This electronic mail message and any files transmitted with it are intended exclusively for the individual or entity to which it is address, with any attachment, may contain confidential and/or privileged information, Any unauthorized review, use, printing, saving, copying,di strictly prohibited.If you have received this message in error,please Immediately advise the sender by reply email and delete all copies. From:William Barnes<william.barnes@inte rstatefireandsfty.net> Sent:Wednesday, September 6, 2023 9:24 AM To:Jerry Kouveras<iouveras@samtell.com>;Alexander Perros <alex@dhgnyc.com> Cc: Ryan Hardy<ryan@dhgnvc.com>;John LoBianco <JLoBianco@Samtell.com> Subject: RE:Silver Sands RE: Interstate Fire I!l I!1 Jerry—best if your team calls— William Barnes Jr. President Interstate Fire&Safety Office 914-937-6100 Office 203-531-1333 Fax 914-937-9723 r Serving the Fire Protection Industry since 1951—please visit https://interstatefireandshy.net/ifs-slideshow on our core values on customer service/life safety This e-mail (and any attachments) may contain proprietary and/or confidential information, and is intended for the individual or entity named above as recipient. It is intended for informational purposes only and does not constitute legal advice. The Information contained in this message may be privileged, confidential and protected from disclosure. If the reader of this message is not the intended recipient, or an employee or agent responsible for delivering this message to the intended recipient,you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please notify the sender immediately and delete this message for your computer. From:Jerry Kouveras<iouveras@samtell.com> Sent:Wednesday,September 6,2023 9:13 AM To:Alexander Perros<alex@dhgnyc.com> Cc:William Barnes<william.barnes@interstatefireandsfty.rl Ryan Hardy<ryan@dhgnvc.com>;John LoBianco<JLoBianco@Samtell.com> Subject: RE:Silver Sands RE: Interstate Fire 9 William-Can you please call the Fire Marshall and ask that if you submit you application to him now electronically-prior to the engineer stamping it-soi he can be assured that all his requests have been met perhaps he can let you complete the install onsite. This sis a very serious issue timing-wise.This process has taken too long. The client needs the kitchen operational ASAP.we need for you to look for methods to push this faster/sooner. Jerry Kouveras - Vice President of Design & Engineering The Sam Tell Companies 36 E 31st Street, 6th Floor, New York, NY, 100i6 F: (212) 244-0057 C: (917) 642-9379 NOTICE:This electronic mail message and any files transmitted with It are intended exclusively for the individual or entity to which it is address, with any attachment; may contain confidential and/or privileged information. tiny unauthorized review, use, printing, saving, copying, di strictly prohibited.If you have received this message in error,please irnmediately advise the sender by reply email and delete all copies. From:Alexander Perros<alex@dhgnyc.com> Sent:Wednesday, September 6, 2023 9:04 AM To:Jerry Kouveras<lkouveras@samtell.com> Cc:William Barnes<william.barnes@interstatefireandsfty.net>; Ryan Hardy<rvan@dhgnvc.com>;John LoBianco<JLoBianco@Samtell.com> Subject: Re:Silver Sands RE: Interstate Fire I am biting my tongue, but this is completely absurd. We communicated very clearly over two months ago. The very simple changes that needed to happen. I was with the Fire Marshall personally'twice last week, both before and after your meeting with him and the day you scheduled to do the install at our property, and he also showed me what a simple request this is. We cannot afford or except any more delays, and the fire marshal has assured me that as soon as you make the very simple changes that you can do the work. Please get this done and scheduled to be here on Friday. I am sorry to be so direct but we cannot afford any more delays on this project. On Sep 6, 2023, at 8:36 AM, Jerry Kouveras <jkouveras@samtell.com>wrote: William-if you can get the engineer to stamp today can it be submitted'electronically to the Fire Marshall? 10 We can call the Fire Marshall once it is in his hands to expedite the approval. Jerry Kouveras Vice President of Design & Engineering The Sam Tell Companies 36 E 31st Street,6th Floor, New York, NY, 10016 F: (212)244-0057 C: (917) 642-9379 NOTICE:This electronic mail message and any files transmitted with it are intended exclusively for the individual or entity to%vhich r with any attachment may contain confidential and/or privileged information.Any unauthorized review, use, printing, saving, strictly prohibited.If you have received this message'n error,please immediately advise the sender by reply email and delete all i From:William Barnes <william.barnes@interstatefireandsfty.net> Sent:Wednesday,September 6, 2023 8:35 AM To:Alexander Perros<alex@dhgnyc.com>;Jerry 'Kouveras<iouveras@samtell.com> Cc: Ryan Hardy<rvan@dhenyc.com>;John LoBianco <JLoBianco@Samtell.com> Subject: RE:Silver Sands RE: Interstate Fire L!l I!1 Alex—no permit I cannot work-- William Barnes Jr. President Interstate Fire &Safety Office 914-937-6100 Office 203-531-1333 Fax 914-937-9723 Serving the Fire Protection Industry since 1951—please visit https://interstatefireandsfty.net/ifs-slideshow on our core values on customer service/life safety This e-mail (and any attachments) may contain proprietary and/or confidential information, and is intended for the individual or entity named above as recipient. It is intended for informational purposes only and does not constitute legal advice. The Information contained in this message may be privileged, confidential and protected from disclosure. If the reader of this message is not the intended recipient,or an employee or agent responsible for delivering this message to the intended recipient, you are hereby notified that any dissemination, li distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please notify the sender immediately and delete this message for your computer. From:Alexander Perros<alex@dhgnvc.com> Sent:Wednesday, September 6, 2023 8:30 AM To:Jerry Kouveras<iouveras@samtell.com> Cc:William Barnes <William.barnes@interstatefireandsfty.net>; Ryan Hardy<rvan@dhgnvc.com>;John LoBianco <JLoBianco@Samtell.com> Subject: Re: Silver Sands RE: Interstate Fire Thank you. Please schedule Friday for the Ansul as I have lined up the other trades (electricians and central fire alarm) for that day. They are confirmed. Also,we have our final electrical inspection on 9/12 so we have to get this done Friday. @William,please confirm ASAP today. Alex On Sep 5, 2023, at 5:13 PM, Jerry Kouveras <jkouverasgsamtell.com> wrote: Alex—the forms are int the hands of William's mechanical engineer and Willaim is going to get us an update tomorrow on them being stamped. @William Barnes Jr:—see below can you schedule a tech for this Friday?Alex can have the electrician there to complete all their scope at the same time. Jerry Kouveras Vice President of Design & Engineering The Sam Tell Companies 36 E 31st Street, 6th Floor, New York, NY, 10016 F: (212) 244-0057 C: (917) 642-9379 NOTICE:This electronic mail message and any files transmitted with it are intended exclusively for the individual or el copying,disclosure or distrihution is strictly prohibited.If you have received this message in error,please immediately 12 From:Alexander Perros <alex@dhgnyc.com> Sent:Tuesday,September 5, 2023 5:06 PM To:Jerry Kouveras <iouveras@samtell.com> Cc: Ryan Hardy<rvan@dhgnyc.com>; John LoBianco <JLoBianco@Samtell.com> Subject: Re:Silver Sands RE: Interstate Fire Ii I!1 Yes. But I need to coordinate the central fire alarm guy to be here the same time as the ansul so he can tie it in. 1. Did he confirm that he updated the plans for the Fire Marshall? I will call the FM to confirm, but he needs to get his plans right. 2.Can he come on Thursday or Friday this week? I will get the other trades here then too if he can confirm the day. On Sep 5, 2023, at 4:52 PM,Jerry Kouveras <iouveras@samtell.co m>wrote: response: "I will do the system any time you wish— the fire extinguishing system micro switch needs to be interlocked to the building fire alarm system, make up air fan needs to be interlock for shut down, all electrical media beneath the hood needs to shut down." 13 Are we all complete regarding the electrical scope and the fans all set? I am going to hold him to his word. Please advise. Regards, Jerry Kouveras T Vice President of Design &Engineering The Sam Tell Companies 36 E 31st Street, 6th Floor, New York, NY, 10016 F: (212)244-0057 C: (917) 642-9379 14 FUSIBLE LINK TEMPERATURE SELECTION ei. ANSUL® SHALL BE PER THE ANSUL INSTALLATION. E5. ELECTRICAL SHUT DOWN (IF REQUIRED) - BY OTHERS . . .MANUAL RECOMMENDATIONS � CONNECTION 70 MAKE UP AIR FAN, SHUT DOWN UPON ACTIVATION (IF REQUIRED CDNNEC7ION BY OTHERS) . 11 _Bn CONNECTION TO HORN STROBE AUDIBLE-DE ICE OR F.A.C.P. ACTIVATES UPON ALL SYSTEM PIPING SHALL BE'. SYSTEM DISCHARGE (SUPPLIED & INSTALLED BY OTHERS) 3/8" BLACK SCHEDULE 40 i 12" DIA DUCT •.. ALL ELECTRIC APPLIANCES " - 11 j,W ' --- — pF NE - �= - 360 60 Eie 360 450 —• - (1)U3AGALLONLTANK - - p 01_20 CART. �P oN IN iN -? m ..( O ) 4 a. ' LOCATED IN END CAP OF.HOOD l 1 1F.. Iq7 IF i 48 22C! 290 . .35'. 40'-48' _ _�� 13"-16' 7 - , ELECTRIC 4T-48" .: a. ° DISCONNECT 1 (BY OTHERS) 2-BURNER; PASTA PLAQUE 2-BURNER : .FRYER RADIANT COOKER 'ANTHANOR RADIANT- 16x.19" REMOTE PULL STATION 12"x24" 12"x16" COOK TOP 12"x24" SHALL BE INSTALLED 42" - 48" ABOVE'THE FINISHED 36".xi6". FLOOR AT A:DISTANCE OF NOT MORE THAN 20FT_FROM ANSUL R102 -. 3 :GALLON SYSTEM THE HDOD. :-IT-SHALL B.E INST.ALLED:IN:THE PATH. OF. TANK: 1: USES: 8 of 11: POINTS: � / VVV " AND A MAXIMUM MOVEMENT OF 14" FOR ACTUATION- NOZZLE SUMMARY TABLEa SYSTEM PIPING LIMITATIONS CLASS x wET'CHEMICAL EXTINGUISHER HAZARD " . QTY NOZZLE PTS . :TOTAL' 3 GALLON er c.tinder / D MORE THAN 60 ABOVE THE f'P Y ) FINISHED FLOOR WITHIN:30-ET- FROM THE HAZARD.._... TANKS 1 & 2 — 2) 3 GALLON TANKS — 22 FLOW-POINTS MAX .. 2-BURNER: 2 iF i 2 DUCT .. PLENUM APPLIANCE -ENGINEERED M P RA NLY P VEERED SYSTE - SHO D WING 0 1/4�E _ 1._OEM- i iN _ _ s REQUIREMENTS -"- SUPPLY BRANCH-. BRANCH BRANCH COOK TOP.: SCALE:. - "' INTERSTATE RE & SAFETY EQUIPMENT 1: 290 2: 2 PIPE SIZE 3 8i`: 3 8t� 3 8�� 3r8��; 75 CALVERT STREET FRYER / ISON, NY.10S28 . 2 :2N: a z MAXIMUM LENGTH 40 FT 8 FT. .. 4 FT 12 FT PLENUM " THE SILVER SANDS MOTEL Dutr 1 1w. i 1. . MAXIMUM RISE 6 FT 4:FT.. .. . 2 FT 2 FT 1400 SILVERMERE'ROAD' M;4X 90 ELB0INS 9. 4 4 6 PORT, NY 11944 TOTAL 8 GREENP .. ..... ... ... ... -. .. .. .. ... .. ... .. - NO .. MAX TEES .: 1 :2-: 2 4 — o Rwc: RV (914) 937 6100 slzE; . .... FIRE:SYSTEM 1 . _. . MAX:FLOW POINTS . 11 4.: 2 4 3[6Wll"E -- scaiE AS NOTED ':3/14/2023 15HiET 2 OF:7:' PIPING- : ISOMETRIC - TANK #1 A . T . 5 i 1W i2. :. H G F 6„ 2.1" 25" 17" 25" 17."_ 22" 6„ B- A 12" IV, E 12" 12" 6„ �, 1N 1N n ANSUL. 24' 24" 24" 36" 3-GAL 1F 1N 1F 250. ANSUL R102 - 3 GALLON SYSTEM TANK 1 - 11 POINTS MAX TANK 1 USES : 8 of 11 POINTS START END FT PIPE SIZE -NOZZLE QTY:.: FLOW PTS . . .. A TANKS 1 & 2 END OF SUPPLY. LINE H._ 13.1 3/8-" B SUPPLY LINE PLENUM NOZZLE 0.:5 . 3:/8" 1N:.- C SUPPLY- LINE FRYER NOZZLE 4.0: 3/8" 290 1 2 --- -- - D- : SUPPLY LINE.-.: 2-BURNER NOZZLE 3.0 3/8"..: 1F I ...: 1 C. E SUPPLY LINE: DUCT NOZZLE .. 0.5 3/81' 1W 1:: 1 `��f NE y Q� F SUPPLY LINE COOK TOP NOZZLE 3.\.0.. :3/8" 1N: . ON ` `. G SUPPLY, LINE 2r.BURNER NOZZLE 3.0 3/8" H SUPPLY LINE... - . . PLENUM NOZZLE 0.5 3/8":. 1N .. W .27.6 7:0 8.0 2 _ 2 842 OFESSIP INTERSTATE EQUIPMENT E FIRE& SAFETY EQUIPME CO. -INC: 75 CALVERT STREET HARRISON, NY,10528 . ALL PIPE LENGTHS ARE ESTIMATES BASED ON SKETCHES AND -/:OR ARCHITECTURAL DRAWINGS FIELD:CONDITIONS MAY REQUIRE- ADJUSTMENT TO THESE-PIPE LENGTHS ./: MEASUREMENTS VERMERE ROAD L THE SILVER 1400.SIL ,. GREENPORT, NY 11944 AT NO POINT SHALL THE:.TOTAL PIPE LENGTHS or PIPE VOLUMES BE ALLOWED TO EXCEED THE MAXIMUM LIMITATIONS ."(914) 937-6100 "SIZE DWG NO DWG REV INSTALLER SHALL ENSURE THAT ALL MINIMUM AND MAXIMUM PIPE LENGTHS, PIPE VOLUMES AND PIPE FITTING:ALLOWANCES ARE MET AT TIME OF INSTALLATION F.IFESYSTM 1 -- - - - SCALE AS NOTED' :3114�2B23 SHEET 3 OF 7- F E yr . .ONY.48421 ,A • I AR�FESS1 I�I wI o - w . LL Will I I L--- \� - w I. \ FRZ: --- I REMOTE PULL. J --- O I. STATION ' ty ANSUL .33:"GALLON TANK & CONTROLS q. INTERSTATE'FIRE 8 SAFETY EQUIPMENT CO. INC. :NOTE : PULL: S TAT I O N IS LESS THAN: 10 F T FROM ": _ 75 CALVERT STREET HARRISON, NY 10528 HAZARD BUT IS IN THE BEST LOCATION. FOR THE SILVER SANDS MOTEL THIS KITCHEN: AND ON THE PATH OF EGRESS FLOOR PLAN 34@OszwERr G NY,REENPDRT, NY 11944944 NOT TO SCALE i (914) 937-6100 sr[e DWG NO DWG aEv FIRE SVSTBR 1 SCALE AS NOTED' 3/14/2023 10FIT 4-0F.7 �. FUSIBLE LINK: TEMPERATURE SELECTION of ANSUL® _ SHALL BE PER THE ANSUL INSTALLATION: ' ( - OTHERS: -MANUAL RECOMMENDATIONS p. ES , ELECTRICAL SHUT DOWN IF REQUIRED) BY 0 NATION ( NECTION BY OTHERS)MU CONNECTION TO MAKE UP AIR FAN,.SHUT DOWN UPON ,ACTT IF REQUIRED CON R§) . p.. CONNECTION TO HORN / E STR08E AUDIBLE'DEVIL OR F CP N 11�-0" ALL SYSTEM PIPING SHALL BE SYSTEM.DISCHARGE (SUPPLIED & INSTALLED BY OTHERS) 3/8"":BLACK SCHEDULE 40 . .. .. .. L .. T. 12" DIA I DUCT77 ALL ELECTRIC APPLIANCES 1W I - I — — F Ne o _ 3 60; 360 450 REGULATED L GALLON TANK EASE w C) CART ( .0. 1N Raa (LOCATED IN END CAP OF HDOD) � ON iN . m % 1N IF l 48 22 290 . • i o� s►oNP�' r 4 8 ELECTRIC Z"-4 " DISCONNECT !All (BY OTHERS) 2-BURNER; PASTA PLAQUE 2-BURNER.: ,FRYER" RADIANT' COOKER 'ANTHANOR RADIANT 16"xi9" REMOTE PULL STATION :12"x24" 12"x16" COOK'TOP"12"x24" SHALL BE INSTALLED 42" - 48" ABOVE THE FINISHED " ANSUL R102 -_3 _GALLON SYSTEMINi:THE PATH OF 3G",xi6" TANK: 1 USES.: 8 of 11: POINTS: THE HOOD. - IT SHALL BE INSTALLED- .EGRESS AND REQUIRE A:MAXIMUM FORCE OF 40 LBS" AND A MAXIMUM MOVEMENT OF 14" FOR ACTUATION NOZZLE SUMMARY TABLE : : :" SYSTEM PIPING LIMITATIONS CLASS K WET CHEMICAL EXTINGUISHER . . . HAZARD SHALL BE IN L' THAN 60" ABOVE . HE QTY NOZZLE PTS TOTAL 3GALLON (per Cylinder) FINISHED FLOOR WITHIN ORFT FROM'THEHAZARD.-" - TANKS 1 & 2 - (2) 3 GALLON TANKS - 22 FLOW POINTS MAX .. . _ 2-BURNER: 2 . . .1F 1 z DUCT. PLENUM: APPLIANCE PRE-ENGINEERED M P DRAWING ONLY P NEERED.SYSTE SHOP D NG .. 1/4" = 1'=0. i 1N 1 1, REQUIREMENTS SUPPLY BRANCH BRANCH• BRANCH :SCALE• COOK TOP..' '... .. . .. ..... . t:' 29e 2: 2 PIPE SIZE 3 R": 3 8" 3 8 3 8": INTERSTA E FI75-CALLVVERTTYSTRR�EIETMENT :FRYER , / / HARRISON NY.1052JA PLENUM 2 1N,_ .: s z MAXI MU M LENGTH 40 FT 8 FT: 4 FT 12 FTDucT 1 sw 1 1. . MAXIMUM RISE 6 FT 4.FT.. .. . 2 FT 2 FT THE SILVER SANDS M1400 SILVERMERE'RTOTAL aMAX 90 ELBOWS 9:: : 4 4 6: : ORT, NY 119 GREENP..... ... - NO MAXTEES 1 •2 ' 2' 4 SIZE. OHG �� ...ONG(914) 937-6180 FIRE'SYSMAX,FLOW POINTS 11 4 ... .. . 2 4SCALE As NOTEo 3/14/2023 SHEET PIPING: _ ISOMETRIC - TANK #1 . T . S 1W H F. 6.. 21P: 25" 17" 25" 1T". 22" B' A 6.. 6„ 12.. 12" E 12". 12" 1 _. 1N . N - it ANSW. : . 24 24 24" 36" 3-GAL pw 1F 1N 1F: 290. . ANSUL .R102 — 3- GALLON SYSTEM " TANK 1 USES:: 8 0 11 POINTS TANK.'1 - 11 POINTS MAX START END FT PIPE SIZE :NOZZLE QTY:-; b'LOW PTS A TANKS 1 & 2. END OF SUPPLY LINE H 13.1 3/8" B SUPPLY LINE PLENUM NOZZLE 0.,5.; 3/8" 1N;.; : 1 C SUPPLY_ LINE FRYER NOZZLE 4.0; 3/8" 290 D SUPPLY LINE...: 2-BURNER NOZZLE 3.0 3/81' . 1F 1 . .: 1 E. SUPPLY LINE: ... .. . DUCT NOZZLE ... .. .- 0.5 3/8,,. 1w 1.: 1 ��oF:NEy j F SUPPLY LINE COOK TOP NOZZLE 3.:0. :3/8" 1N: : : 1 G SUPPLY. LINE 2rBURNER NOZZLE 3.0: ..3/8" H SUPPLY LINE.:.: PLENUM NOZZLE 0.5 3/8"' 1N 1' 1 x a . .. . 27.6 7.0 8.0 C9= . 842Z �ss►o�'P INTERSTATEEQUIPMENT 'FIRE SAFETY EQUIPME CO.' INC: ' 75 CALVERT STREET . _... ... - HARRISON, NY,10528 ALL PIPE LENGTHS ARE ESTIMATES BASED ON SKETCHES AND:/:OR ARCHITECTURAL DRAWINGS .THE SILVER SANDS MOTEL FI'ELD. CONDITIONS MAY REQUIRE ADJUSTMENT TO THESE PIPE LENGTHS../: MEASUREMENTS NY 11944 1 SIL E 0 ,.; ORT,GREENP AT''NO- POINT SHALL THE TOTAL PIPE LENGTHS or PIPE VOLUMES BE ALLOWED TO EXCEED THE MAXIMUM LIMITATIONS ... .. ..-.. .. ..M ... .. t6 REV .. .. .. (914) 937-6100 SIZE• DWG D INSTALLER SHALL ENSURE THAT ALL MINIMUM AND MAXIMUM. PIPE LENGTHS, PIPE VOLUMES AND PIPE FITTING:ALLOWANCES ARE MET AT TIME OF INSTALLATION- FIRE SYSTEM - 1 ' SCALE as NDTED,� "3/14/2023 SHEET 3�OF:7 ' o pp for NEW 4 �•�� 04y 'A / Ia 48422 _. 1' . AR�FESSIQNP� -7 - % r=� o I r i w III \ c m r -ZM o _�.__� � . III I I:I I I LLI I it 1;�9411;14 I L� o --_ L. Id 111 la ei I Ld L Ir.I RZ --- ---- L i REMOTE. PULL: o is .. --- I' STATION =_ ... \ LL W. lads i�i�l�l �:P ANSUL: 3-GALLON TANK & CONTROLS INTERSTATE FIRE 6 SAFETY EQUIPMENT CO, INC. ; :NOTE : PULL STATION IS LESS THAN: 10FT FROM:: 75 CALVERT STREET HARRISON, NY 10528 HAZARD -BUT IS IN THE BEST LOCATION :FOR mq THE 1400ISILVERMERE ROADLVER SANDS L THIS KITCHEN, AND ON: THE PATH OF . EGRESS FLOOR PLAN GREENPORT, NY 11944 . - ... IZE 01lG NO REV NOT TO SCALE (914) 937-6100 s FIRE SYSTEM 1 .. .. .. .. .. .. .. .'. SCALE AS NOTED 3/14/2023 SHEET 4 OF..] FUSIBLE LINK TEMPERATURE SELECTION #JANSU SYSTEM SHALL MEET FFOLK COUNTY FIRE SHALL BE PER THE ANSUL INSTALLATION ES ELECTRICAL SHUT DOWN (IF REQUIRED) : BY OTHERS PREVENTION ORDINANCY, NFPA 17A (2017 ED) MANUAL RECOMMENDATIONS NFPA 96 (2017 ED , NFPA 10 (2018 ED.), � MU CONNECTION TO MAKE UP AIR FAN, SHUT DOWN UPON NYS BUILDING (2020 ., FIRE & MECHANICAL CODES r ACTIVATION (IF REQUIRED CONNECTION BY OTHERS) CONNECTION TO HORN STROBE / AUDIBLE DEVICE OR ALL SYSTEM PIPING SHALL BE li'-0." F,A.C.P. ACTIVATES UPON SYSTEM DISCHARGE - 3/8" BLACK SCHEDULE 40 (SUPPLIED & INSTALLED BY OTHERS) 18" A DUCT I ALL ELECTRIC APPLIANCES 2W I ------- ........ �--y-------- ----- --- - I REGULATED RELEASE � 5 368 60 3G8 368 450 (1) 3-GALLON TANK - 101-28 CARTRIDGE IN IN ue m (LOCATED IN END CAP OF HOOD) a rh. n i _ m I I 6" MIN IF 1N 1F 6"MIN ,. OVERHANG 29 OVERHANG T , 1.49. 35--40' - I I I I I ELECTRIC 48" IE, DISCONNECTii (BY OTHERS) _..._.' ..._.._... __._.._,,.__.._.............. ... .. .. ... .. �2-BURNER;...PASTA -"PLAQUE�-'2-BURNER' -FRYER.-._._ . __... _._, ,....._ ......_......._...._......._....... ._._ _............._........ ...___,__......_......_,..__.. __.,......._... REMOTE PULL STATION RADIANT COOKER O RADIANT 16"x19" 12"x2A" 12"xl6" COOK SHALL BE INSTALLED 42" - 48" ABOVE THE FINISHED COOK TOP 12"x24" 36"xl_6" FLOOR AT.A DISTANCE OF NOT MORE THAN 2OFT FROM THE HOOD. IT SHALL BE INSTALLED IN THE PATH OF EGRESS AND REQUIRE A MAXIMUM FORCE OF 40 LBS ANSUL R102 3 GALLON SYSTEM AND A MAXIMUM MOVEMENT OF 14" FOR ACTUATION - TANK 1 USES: 9 of 11 POINTS SYSTEM PIPING LIMITATIONS CLASS K WET CHEMICAL EXTINGUISHER - SHALL BE INSTANLED NO MORE THAN 60" ABOVE THE 3 GALLON (per FINISHED FLOOR WITHIN 30 FT FROM THE HAZARD. NOZZLE SUMMARY TABLE (A cylinder) HAZARD QTY I NOZZLE PTS TOTAL PRE-ENGINEERED SYSTEM SHOP DRAWING ONLY TANK 1 - 3 GALLON TANK - 11 FLOW POINTS MAX DUCT PLENUM APPLIANCE SCALE: 1/4" = 1'-0" 2 1F 1 2 REQUIREMENTS SUPPLY BRANCH BRANCH BRANCH INTERSTATE FIRE &SAFETY EQUIPMENT CO. INC. 2-BURNER it rr " PIPE 512E 3/8 3/8 3J8 3/81 1 75 CALVERT STREET COOK TOP 1 SN 1 1 HARRISON, NY 1852E MAXIMUM LENGTH 40 FT 8 FT 4 FT 12 FT FRYER 1 290 2 2 THE SILVER SANDS MOTEL MAXIMUM RISE 6 FT 4 FT 2 FT 2 FT, 1400 SILVERMERE ROAD PLENUM 2 1N 1 2 MAX 90 ELBOWS 9 4 46 GREENPORT, NY IL944 Ducr 1 2w 2 2 MAX TEES 1 2 2 4 (914) 937-6160 sizE DYG No ax REV KITCHEN FIRE SYSTEM 4 TOTAL 9 MAX FLOW.POINTS 1 11 1 4 2 4 - _ SCALE AS NOTED 9/5/2023 SMFET 1 OF'3 PIPING ISOMETRIC - TANK #1 N . T . S 2W '12" $„ 10" t 621 25" 17" 25" 17" 22" B 6, 12" 121, E 12" 12" 6" IN 1N 31ANSU.- 24" 24" 24" 36" AL IF 1F 1N 1F 290 ANSUL R102 - 3 GALLON SYSTEM TANK 1 USES: 9 of 11 POINTS --- - TANK 1 — 11 POINTS MAX START END FT PIPE SIZE NOZZLE QTY FLOW PTS A TANKS 1 & ,2 END OF SUPPLY LINE H 13.1 3/8" B SUPPLY LINE PLENUM NOZZLE 0.5 3/8" '1N 1 1 C SUPPLY LINE FRYER NOZZLE 4.0 3/8" 290 1 2 D SUPPLY LINE 2—BURNER NOZZLE 3.0 3/8" IF 1 1 E SUPPLY LINE DUCT NOZZLE 0.5 3/8" 2W 1 2 F SUPPLY LINE COOK TOP NOZZLE 3.0 3/8" 1N 1 1 G SUPPLY LINE 2—BURNER NOZZLE 3..0 3/8" 1F 1 1 H SUPPLY LINE PLENUM NOZZLE 0.5 3/8" 1N 1 1 INTERSTATE FIRE &SAFETY EQOIPMENT,CO. INC. 27"E �'d 9' 75 CALVERT STREET HARRISON, NY 10528 ALL PIPE LENGTHS ARE ESTIMATES BASED ON SKETCHES AND / OR ARCHITECTURAL DRAWINGS {p ' THE SILVER SANDS MOTEL FIELD CONDITIONS MAY REQUIRE ADJUSTMENT TO THESE PIPE LENGTHS / MEASUREMENTS 1400 SILVERMERE ROAD GREENPORT, NY 21944 AT NO POINT SHALL THE TOTAL PIPE LENGTHS Or PIPE VOLUMES BE ALLOWED TO EXCEED THE MAXIMUM LIMITATIONS size owe No ouc rtEv (91A)'937=61ee INSTALLER SHALL ENSURE THAT ALL MINIMUM AND MAXIMUM PIPE LENGTHS, PIPE VOLUMES AND PIPE FITTING ALLOWANCES ARE MET AT TIME OF INSTALLATION 1.11IN FIRE SrsTEn 4 SJXl1/,t I SCALE as xoTeo 9/5(2023 SHEET 2 OF 3 �I t f� 1 I Li �Ilil i i 1 ' I r---------------- 1 ; i 0 i m `�----n l Lr I I i I fig 1 Fj col -0 - =L�4 y I f I 7 7 71000 , Of I' 1 � IFRZ REMOTE PULL ��r I STATION �titdil lililil � P '1+41d biJJ � i; t �ANSUL 3—GALLON TANK & CONTROLS INTERSTATE FIRE &.SAFETY EQUIPMENT CO, INC. 75 CALVERT STREET HARRISON, NY 10528 NOTE : PULL STATION IS LESS THAN 10FT FROM �`` THE SILVER SANDS MOTEL HAZARD BUT IS IN THE BEST LOCATION FOR FLOOR PLAN 1400 Pa TER NY 119 4 THIS KITCHEN AND ON THE PATH OF EGRESS NOT TO SCALE ,c914;,937_6100 SIIE o 'No 'IV FIRE SVST. 4 z ea '.sGIE AS NOTEQ 9/5/2023 SHEET 3 OF 3 s s(� ,g � • l ,�p� r'� SYSTEM REQUIREMENTS: • Kitchen Fire Suppression System should be designed for protecting kitchen hood, plenum, exhaust duct,grease filters and cooking appliances from grease fires. • The Fire Suppression System should be of the stored pressure, wet chemical pre- engineered fixed nozzle type. • The system shall be tested to the UL Standard for fire extinguishing system for protection of Restaurant Cooking Fires,UL300 and Listed by Underwriters Laboratories Inc. • It shall be installed in accordance with the National Fire Protection Association Standard #17A Wet Chemical Extinguisher Systems and#96 Standard for the installation of equipment for the removal of smoke and grease laden vapor from commercial cooking equipment. • All electrical work(if required) shall comply with NFPA70 National Electrical Code. • All fire alarm work shall comply with the National Fire Alarm NFPA 72 code. • All work shall comply with all local and/or state codes and standards. SYSTEM ACTIVATION: , • The system shall be capable of automatic and manual actuation • Automatic actuation shall be provided by and appropriate number of fuse link detectors mounted in series on a stainless steel wire input line connected to the system control head. • Manual actuation shall be provided by a remote pull station with a dedicated stainless steel input line connected to the system control head. • The remote pull station shall be installed at a height of not more than 48" above the finished floor and a distance of at least 10' feet but not greater than 20' feet from the hazard in the path of egress. FUEL SHUT-OFF: • The system shall be equipped with a means to shut off the cooking fuel. • Automatic gas shut-off valve should be installed before the first cooking appliance. Gas valve should comply with the requirements pertaining to the shut-off or fuel as described by NFPA 17A • The automatic fuel shutoff valve shall be installed below the ceiling line and be accessible for service EXHAUST FANS&MAKE UP AIR: • System shall be rated for operation with the exhaust fan on or off. • In case of make-up air supplied to the hood it must shut down upon system actuation. Items such as exhaust fan (s)may remain on. Fire Extinguishing System Micro Switch: • The fire extinguishing system micro switch shall be interlocked to the building fire alarm system as to activate such during a system discharge • The fire extinguishing system micro switch shall be interlocked to the make up air fan as to shut down such during a system discharge • The fire extinguishing system micro switch shall be interlocked with any electrical/ energized media beneath the ventilation hood as to shut down such during a system discharge • The fire extinguishing system micro switch shall be wired by electrical contractor/fire alarm company outside the fire extinguishing system control head ELECTRICAL NOTES: • All electrical work including electrical shut down of power under the hood and the make-up air shall be performed by others. FIRE EXTINGUISHER REQUIREMENTS: • K Rated Extinguisher shall be provided as per NFPA 10,Standard for Portable Fire Extinguishers. Shall be installed in cooking area and identified with signage stating activate fire extinguishing system prior to the use of this extinguisher. Fire Extinguishing System Drawings: • Fire Extinguishing System drawings indicate code compliance. Field conditions can alter fire extinguishing system cylinder location and remote manual release location. Liability: • It is the owner's, occupant's,tenant's responsibility to maintain all associated equipment affecting the fire extinguishing system's ability to operate as designed and ability to maintain the manufacturer's UL listing per the applicable sections of the State Code, Local Fire/Mechanical Code and the applicable sections of the N.F.P.A. 96/ 17A Fire Code. 0 SYSTEM REQUIREMENTS: • Kitchen Fire Suppression System should be designed for protecting kitchen hood, plenum, exhaust duct,grease filters and cooking appliances from grease fires. • The Fire Suppression System should be of the stored pressure, wet chemical pre- engineered fixed nozzle type. • The system shall be tested to the UL Standard for fire extinguishing system for protection of Restaurant Cooking Fires, UL300 and Listed by Underwriters Laboratories Inc. • It shall be installed in accordance with the National Fire Protection Association Standard #17A Wet Chemical Extinguisher Systems and#96 Standard for the installation of equipment for the removal of smoke and grease laden vapor from commercial cooking equipment. • All electrical work(if required) shall comply with NFPA70 National Electrical Code. • All fire alarm work shall comply with the National Fire Alarm NFPA 72 code. • All work shall comply with all local and/or state codes and standards. SYSTEM ACTIVATION: • The system shall be capable of automatic and manual actuation { • Automatic actuation shall be provided by and appropriate number of fuse link detectors mounted in series on a stainless steel wire input line connected to the system control head. • Manual actuation shall be provided by a remote pull station with a dedicated stainless steel input line connected to the system control head. • The remote pull station shall be installed at a height of not more than 48" above the finished floor and a distance of at least 10' feet but not greater than 20' feet from the hazard in the path of egress. FUEL SHUT-OFF: f • The system shall be equipped with a means to shut off the cooking fuel. • Automatic gas shut-off valve should be installed before the first cooking appliance. Gas valve should comply with the requirements pertaining to the shut-off or fuel as described by NFPA 17A • The automatic fuel shutoff valve shall be installed below the ceiling line and be accessible for service EXHAUST FANS&MAKE UP AIR: • System shall be rated for operation with the exhaust fan on or off. • In case of make-up air supplied to the hood it must shut down upon system actuation. Items such as exhaust fan (s) may remain on. Fire Extinguishing System Micro.Switch: • The fire extinguishing system micro switch shall be interlocked to the building fire alarm system as to activate such during a system discharge • The fire extinguishing system micro switch shall be interlocked to the make up air fan as to shut down such during a system discharge • The fire extinguishing system micro switch shall be interlocked with any electrical/ energized media beneath,the ventilation hood as to shut down such during a system discharge • The fire extinguishing system micro switch shall be wired by electrical contractor/fire alarm company outside the fire extinguishing system control head ELECTRICAL NOTES: • All electrical work including electrical shut down of power under the hood and the make-up air shall be performed by others. FIRE EXTINGUISHER REQUIREMENTS: • K Rated Extinguisher shall be provided as per NFPA 10,Standard for Portable Fire Extinguishers. Shall be installed in cooking area and identified with signage stating activate fire extinguishing system prior to the use of this extinguisher. Fire Extinguishing System Drawings: • Fire Extinguishing System drawings indicate code compliance. Field conditions can alter fire extinguishing system cylinder location and remote manual release location. Liability: • It is the owner's, occupant's, tenant's responsibility to maintain all associated equipment affecting the fire extinguishing system's ability to operate as designed and ability to maintain the manufacturer's UL listing per the applicable sections of the State Code, Local Fire/Mechanical Code and the applicable sections of the N.F.P.A. 96/ 17A Fire Code. INSTALLIN0 c(ATIPACTer r-ME ABT DESIGN&FIRE PROTECTION ,. {C I it I " '�I' /� ry 1724 CHURCH STREET MAR 2 HOLBROOK, NY 11741 , 631-878-4896 FAX#631-878-5727 NASSAU COUNTY LIC#406/962 SUFFOLK COUNTY LIC#111 4Cd,rsrr�(7F (itfd 9_i1 HUNTINGTON LIC#F210961 EMAIL:ABTFIRE@YAHOO.COM FRONT VIEW SIDE VIEW LOCATION: 114"SCALE 1/4" SCALE SILVER SANDS 1400 SILVERMERE RD BUILDING HAS GREENPORT, NY 11944 FIRE ALARI',1 FIRE SPRINKLER SYSTEM DRAW BY: ANDREA BAYARD ON 03/17/2023 KITCHEN x All Views to the following scale 1/ _Dimensions x New Kitchen _Existing Kitchen NON Combustible[Masonry] _Limited Combustible-[S/Rock-Metal Stud]] _Combustibles x FIRE RATED WALLS-2 hr _Exiting—1 HR OK _Special Sprinkler Instillation-1 hr ok x OPENING PROTECTIVE[11%hr]—[self closing,latching,fire rated door assembly] Special Sprinkler Instillation%hr ok OR _OK WITHOUT Opening Protective's If ALL the following comply: 1 U MIN TO ANY AIR . 10'MIN TO ANY AIR *Draft Curtain 24"ht[NC/LC] *Hds/Aes *Special Sprinkler Installation INTAKE INTAKE PLEASE SEE Exit at Grade---or--Sprinkler heads within 24 inches of draft curtain,60 inches apart,kitchen side ELECTRICAL NOTES DAYTON DAYTON g Equipment �— g Equipment g Equipment g MODEL#7A623 Z MODEL#7A631 Cooking E ui ment in the kitchen Cooking E ui ment at the front counter Cooking E ui ment in the dining room AT BOTTOM OF PA c GREASE COLLECTOR BOX 2750 CFM o 4800 CFM _Cooking Equipment in a mobil unit_Cooking Equipment in a co cession stand_Pizza Oven MAKE UP AIR DAYTON HOOD MODEL#7D496 120V SERVICE SWI ���� C �c 1950 CFM ��015 W°Op _Exhaust cfm-Medium Duty yExhaust cfm—Heavy Duty _Exhaust drn—Extra Heavy Duty y �pO JOISrR [hot top,griddle,fryers,pizza,rotisseries] [range,wok,gas/elec broilers] [Solid fuel char broilers] [Wall-Linear Ft x 300][S-island Linear Ft x 500] [Wall-Linear Ft x 400][S-island Linear Ft x 6001 [Wall-Linear Ft x 550][S-island Linear x 700] RIDGE HEIGHT RIDGE HEIGHT x Liquid tight external weld x 12 ft max hood length per exhaust riser x 18 ga Stainless ITT" 13-0" 18"ROUND X Supply Air 100%approx replacement _Supply air deg difference except A/C_Supply air hood damper(286 deg max) WELDED DUCT wO0O °/s _Clearance-3"to Combustibles,including 1 inch mineral wool,(insulate the combustible not the hood) °pa xClearance-3"to Limited Combustible _Clearance-0"to Non Combustible X Insulation—max Flame Spread Rating 25/x w18 ROUND DUCT CHARBROILERS-4'min to hood _Solid fuel to have spark arrestors _Solid fuel—under separate hood FIREMASTER x FRYER—16-inch space to the flame producing appliance or 16 inch high steel baffle FASCLEAR XIL N FILTERS to heat source 18-inch minimum To flue baffles 6 inch minimum(uprights,rotisseries,ovens,etc FOR 0"—CLEARANCE TO _IL —� ) COMBUSTIBLES x6 inch overhang all sides x 7ft maximum off floor x 24 inch minimum height all sides FIREMASTER x LISTED HOOD installed in accordance with terms of its listing. x Elec.Wire in conduit or EMT FASTWRAP XL DUCT THERMOLOUPLING TURNS CAPTIVE AIRE Manufacturer 2750 Exhaust x Clearance(Hood bottom to appliance top) FAN ON UPON SENSING DUCT FOR D"—CLEARENCE TO 91 DEGREES OPENING SND-2-PSP-F Model _Su I cfm Maximum Cookin surface temGE COMBUSTIBLES 1 g5Q LOCATED IN CAPTURE AREA OF HOOD NOT OPENING 18"ROUND Supply — 9 P ALSOWITHI AS MANUAL SWITCH DUCTS ,, FAN ALSO HAS MANUAL SWITCH 1S"ROUND X AIRFLOW of 1500 ft/minute minimum X Dimensions(L x W x H) 18"ROUND x 16 ga steel X Field welds to be Bell or Telescoping PSP--► x Duct exits bldg directly as possible x Horizontal duct travel less than 75' X Duct connections to have flush bottoms A I 3"STANDOFF x Liquid tight external weld x No exhaust dampers use x Duct pitched back hood to collect grease x Ducts not shared by others systems xShall not pass thru firewalls x Not insulated until inspected 11'x 54"x 18"FRONT/24"REAR _CLEARANCE-3"minimum from combustibles,including 1-inch mineral wool,(insulate the combustible not the duct) X Clearance-3"to Limited Combustible _Clearance-0"to Non Combustible GREASE COLLECTOR BOX x ACCESS PANELS—to be unobstructed _Within 3 ft each side of an inline fan X Signs-'Access panel—D°Not Obstruct' STAINLESS STEEL _20 Feet Horizontally _At every floor Vertically _At every direction change WALL COVERING _Access door at vertical riser base xDuct Secured to bldg x EXTERIOR—Weatherproofed _ENCLOSURES in building more than 1 floor ceiling above hood or through any concealed spaces ducts shall be enclosed *Penetrating floors&ceilings *6 inches between duct&enclosure *vented at roof _Though Penetration Fire Stop System as alternative to enclosures with 6"airspace shall have a minimum 3"inclusive airspace, APPLIANCE depending on mfg. LINE FAN ATHANOR E-SUITE COOKING APPLIANCE X TERMINATES—at building exterior up and away from roof X 40 inches from roof(See Drawing a Notes) _XFan hinges away from duct,with hold open retainer&flexible waterproof cable X Grease drains back to trap at fan xMinimum 10'to air intakes,property lines,windows,doors or 3"vertical x Safe access area for servicing ���, _Non-Combustible side fan termination ok,no openings 10'horizontal vertical down,32'vertical up,except char-broilers not KOOQ permitted NOTES FLOOR PLAN ELECTRICAL CONDUIT MUST RUN THROUGH CURB&BETWEEN ROOF& ENCLOSURE ---_�_ ELECTRIC RUN FROM CURB TO FAN TO BE DONE WITH SEALTIGHT CABLE AND MUST LEAVE ENOUGH SLACK TO ALLOW FAN TO HINGE BACK FOR DUCT CLEANING EXHAUST FAN AND RETURN AIR FAN TO BE ELECTRICALLY INTERLOCKED ELECTRICAL DONE BY OTHERS CUMnr xYba ' -This installation is in accordance with the Mechanical Code of New York State, Fire ppip 1 d N' code of NYS, applicable codes of the Town of Southold and NFPA. JI cc ck N v— r- '— I •iii iiHrt �. O I ,�, S+f �+ 1 FRZ I -- M-0 I FA I INSTALILINC, C®NTUACT®I? rT7"2r_ ABT DESIGN&FIRE PROTECTION :rf,ry, 4r 1724 CHURCH STREET HOLBROOK, NY 11741 631-878-4896 FAX#�P878Z_727 NSUFFOLK COU l�,�d67962 ��' '� (VI �°�, ps HUNTINGTON LM-F 10d�1Y U �`°�r! 5qOCC 0 g C'f� O EMAIL:ABTFIRE@YAMO.COM �D2 APPROV3ED AS NOT�jED 6 IS U � FRONT VIEW SIDE VIEW DATE-`''`Y/ B.P. # Y" FURL �OC,�T®®Ni t II�rtIF$nd11 LD 1/4"SCALE 1/4" SCALE r(' � 0,- s r WITHOUT CERTIFICATE SILVER SANDS FEE. BY M NOTIFY BUILDING DEPARTMENT AT F OCC U rq �/ 1400 SILVERMERE RD BUILDING HAS 765-1802 8 AM TO 4 PM FOR THE GREENPORT, NY 11944 1.OFOUNDATILLOVVING NSPON -TWO ?E(iUIRED FIRE ALARh" FIRE SPRINKLER SYSTEECTIONS MFOR POURED CONCRETE 2 ROUGh-FRAMING, PLUMBAG, DRAW BY: ANDREA BAYARD ON 03/17/2023 STRAPPING. ELECTRICAL & CAULKING ELECTRICAL ANDREA BAYARD-REVISION#1-0510412023 3 INSULATION INSPECTION REQUIRED 4 FINAL-CONSTRUCTION &ELECTRICAL MUST BE COMPLETE FOR C.0 KITCHEN x All Views to the following scale �� _Dimensions ALL CONSTRUCTION SHALL MEET THE x New Kitchen _Existing Kitchen REQUIREMENTS OF THE CODES OF NEW r1RE INSPECTION _NON Combustible[Masonry] _Limited Comb ustible-[S/Rock-Metal Stud]] _Combustibles YORK STATE. NOT RESPONSIBLE FOR REQUIRED CEPO3E x FIRE RATED WALLS-2 hr _Exiting-1 HR OK _Special Sprinkler Instillation-1 hr ok DESIGN OR CONSTRUCTION ERRORS. w, r_ x OPENING PROTECTIVE[1%hr]-[self closing,latching,fire rated door assembly]_Special Sprinkler Instillation'/4 hr ok ®I 1:1:IA� OR _OK WITHOUT Opening Protective's if ALL the following comply: 1O'MIN TO ANY AIR 10'MIN TO ANY AIR 1 i Draft Curtain 24"ht[NC/LC] *Hds/Aes *Special Sprinkler Installation INTAKE INTAKE PLEASE SEE Exit at Grade---or---Sprinkler heads within 24 inches of draft curtain,60 inches apart,kitchen side DAYTON 3 DAYTON ELECTRICAL NOTES MODEL#7A623 z MODEL#7A631 _Cooking Equipment in the kitchen y Cooking Equipment at the front counter—Cooking Equipment in the dining room AT BOTTOM Tr A GREASE COLLECTOR BOX 2750 CFM 4 4800 CFM _Cooking Equipment in a mobil unit_Cooking Equipment in a concession stand_ Izza Oven MAKE UP AIR - /� M DAYTON SERVICE HING P' � � ,�•'.. O/ � e t* ) MODEL#7D496 ✓�;`� I E HOOD 12ov sERVIcE svvl 1950 CFM OOpW00p✓0 L':�"�:�w.� i I"�[� �11��.; �! .,',`,r _Exhaust cfm-Medium Duty Exhaust cfm-Heavy Duty _Exhaust cfm-Extra Heavy Duty y w [hot top,griddle,fryers,pizza,rotisseries] [range,wok,gastelec broilers] [Solid fuel char broilers] [Wall-Linear Ft x 3001 IS-island Linear Ft x 5001 [Wall-Linear Ft x 400][S-island Linear Ft x 600] [Wall-Linear Ft x 550)[S-island Linear x 700] RIDGE HEIGHT RIDGE HEIGHT X Liquid tight external weld x 12 ft max hood length per exhaust riser x 18 ga Stainless 13-0" 13'0" 18"ROUND X Supply Air 100%approx replacement _Supply air deg difference except A/C_Supply air hood damper(286 deg max) WELDED DUCT W00D poi _Clearance-3"to Combustibles,including 1 inch mineral wool,(insulate the combustible not the hood) 0 F xClearance-3"to Limited Combustible _Clearance-0"to Non Combustible X Insulation-max Flame Spread Rating 251x 18"ROUND WELDED DUCT CHARBROILERS-4'min to hood _Solid fuel to have spark arrestors _Solid fuel-under separate hood FIREMASTER x FRYER-16-inch space to the flame producing appliance or 16 inch high steel baffle FASXL * FILTERS to heat source 18-inch minimum xc To flue baffles 6 inch minimum(uprights,rotisseries,ovens,etc) F� R 0"-CLEARANCE AP ARANN CE TO COMBUSTIBLES x6 inch overhang all sides x 7ft maximum off floor x 24 inch minimum height all sides FIREMASTER xLISTED HOOD installed in accordance with terms of its listing. x Elec.Wire in conduit or EMT THERMOCOUPLINGTURNS FASTWRAP XL Manufacturer 2750 Exhaust x Clearance Hood bottom to appliance to FAN ON UPON SENSING FOR DUCT CAPTIVE AIRE ( Pp p) 900EGREES DUCT OPENING 1950 LOCATED IN CAPTURE AREA OF HOOD NOT OPENING COMBUSTIBLES sND-2-PSP�Model _Supply cfm _Maximum cooking surface temp WITHIN S-OF ANY EDGE 18"ROUND DUCTS FAN ALSO HAS MANUAL SWITCH 18"ROUND X AIRFLOW of 1500 ft/minute minimum x Dimensions(L x W x H) 18"ROUND x 16 ga steel X Field welds to be Bell or Telescoping PSP =* _ x Duct exits bldg directly as possible x Horizontal duct travel less than 75' X Duct connections to have flush bottoms �' N a Y STANDOFF x Liquid tight external weld X No exhaust dampers use X Duct pitched back hood to collect grease •Ducts not shared by others systems xShall not pass thru firewalls xNot insulated until inspected I V x 54"x 18"FRONT/24"REAR _CLEARANCE-3"minimum from combustibles,including 1-inch mineral wool,(insulate the combustible not the duct) X Clearance-3"to Limited Combustible _Clearance-0"to Non Combustible GREASE COLLECTOR BOX x ACCESS PANELS-to be unobstructed _Within 3 ft each side of an inline fan X Signs-'Access panel-Do Not Obstruct' STAINLESS STEEL _20 Feet Horizontally _At every floor Vertically At every direction change ` WALL COVERING _Access door at vertical riser base xDuct Secured to bldg x EXTERIOR-Weatherproofed _ENCLOSURES in building more than 1 floor ceiling above hood or through any concealed spaces ducts shall be enclosed �✓� �I *Penetrating floors&ceilings *6 inches between duct&enclosure *vented at roof _Though Penetration Fire Stop System as alternative to enclosures with 6"airspace shall have a minimum 3"inclusive airspace, APPLIANCE FAN depending on mfg. LINE ATHANOR E-SUITE COOKING APPLIANCE X TERMINATES-at building exterior up and away from roof X 40 inches from roof(See Drawing&Notes) X Fan hinges away from duct,with hold open retainer&flexible waterproof cable x Grease drains back to trap at fan •Minimum 10'to air intakes,property lines,windows,doors or 3"vertical x Safe access area for servicing —Non-Combustible side fan termination ok,no openings 10'horizontal vertical down,32'vertical up,except char-broilers not permitted FLOOR PLAN NOTES ELECTRICAL CONDUIT MUST RUN THROUGH CURB& BETWEEN ROOF&ENCLOSURE ------ ELECTRIC RUN FROM CURB TO FAN TO BE DONE WITH SEALTIGHT CABLE AND MUST LEAVE ENOUGH SLACK TO ALLOW FAN TO HINGE BACK FOR DUCT CLEANING e� EXHAUST FAN AND RETURN AIR FAN TO BE ELECTRICALLY INTERLOCKED C-4 61 SX93 rn m 03 t` 0 } _ ELECTRICAL DONE BY OTHERS tl^!X1 IKYnII � . -This installation is in accordance with the Mechanical Code of New York State, Fire ' 1 code of NYS, applicable codes of the Town of Southold and NFPA. CODE REFERENCES M r THIS INSTALLATION IS IN CONFORMANCE WITH -NFPA 96 -2017 46. a t _ -NYS MECHANICAL CODE 506,507,508 P� -ASTM E2336-2016SS1� ' � v -THE BUILDING AND FIRE CODES OF NEW YORK STATE-2020 von 1 CCC 1 FRZEN M-0 r 14 1 _ REVISIONS NO TAG PACKAGE III LOCATION SORCHES OPTION FANS CONTROLLED 0 0 0 J LOCATION OUANTITY TYPE 4 HP VOLT RA m 1 DCV-1111 WALL MOUNT IN SS BOX SS WALL MOUNT BOX , LIGHT SMART CONTROLS Df.Y Ex WUST 3 00 208 102 1 FAN SUPPLY 3 _OD 208 10.2 4 JOB NO MODEL NUMBER "'a' ESCRI .r I DCV-1111 1fsrMr. , � raw afrr r L aI.ar rrr ar 5686264 R `"A� "ILR� rr r r t1#M n°REn11EE.ALL ft1QRl'AC�mNc b A1b. ALL RIMW CC$010 18 A�n, MOTOR POWER CIRCUIT LOB NAME flM,bax,Il.b1 oM.xo =',I rlxx�Fx ra..S':i,f,"�Y irw�=i "' c �1 141M F Ma tw 1"f}f10oyy wprt laE L1•U Tar I 1 J9 1 F 1W IVte4P1f Ise1'.Fffel�E Lt s R p�NE� t ECpllC3 c"I C D • __H ZHO.L,Il-OIPUTEUTR1e, IM ° u/N r�pW.oSmU � - u 22 1 BREAKER PANEL TO PRIMARY CONTROL PANEL CONTROL PANEL TO ACCESSORY REVS -- �� - __fW eRENER rm NCIp 24V m X � Fii�'o Y �.,��=, I o ° D�trkp!� �� aetrklan our , ______ elAxoew _ gRc° m sHuNr mr Nrxienn pC� 7 I ° A W.SRE 5 TIE MA Vuw M10}�FO y�� ------- � = 2 --NSTAIiMb SCiEMATC v HOW., O I_' OWF I FOR AODIIIO REq ° IA `■■■■■■ N TEHMIt+4L MSEO FOR e7 �\ d 3 La m 12ov aowEREo cns E)� o -------------x a,,� o _> /pml 1M ----------- JfffK f0 _—VALVES ONLY �2 - y _j A raa ssdl ------------ -- Ccv tfcm ------------ fo + PANEL IDq°tom..=�r-- am fA ° u/rl nm q l ry -- - r fAw r r - m - - -----------__- ,o - .� r �' � ° v/c . fax,om,an wua frwm�/,arxxn a�clf�eam ---- ff¢-- 3 Naew�a�M�A+ r r rrr m A V. � � .•� U .:.::, � aF.xmesn .Mawlf=====__ . ----------f4�5 �I r¢I-=Mm w- BM yiy = .b. "'tz� rrrr _ : :11 __ � --- J}-{1y�•7�� t, . ---- --- � '��'- ,��^� ass.. _ I WA l�eaMn� __ __ may. t „,•. '-'LING m A __� �qW L tlW � � �..- �� en. .., y',.::, AR mlmaE J4 AL r/,:fCaA' � BF/IEII dRl ----__ _ ea� T� � LL TF�/!✓p q � N (kae TIBIA __--__ _-� ,q 12GY 4aar�o A #W m T� M V=aI�1Ec�la �t aNl m L K 5 f�CO�� MF A ode d)AF 61® Q ¢ - CONTROL PANEL TO FANS °0M ------------ -'+ T ® d 4 Reye,axl6%Ir DxalrkA"a fofrfq ffok �JW F gip!wtr faa" faaffs,m_I�/u w _.fwfa�_ auc of _ate+ t _ 1 t> E, rRT f now MnMrm N mMnr my uFR f _ N1 Z p • 3o HaKK 1 a�dPlr b a :5 Lu -1M1fV_ q/-2 r�1�,� wee � f0 h p° _rvaaA_ ix JLryQ.l��Y3R. -OCA' CRY fpNTACeS(9fr>1M DE-ENERazm) M.i F.-aey �` i ° m — A— mrarwME lox i�IL _—•'v"-� —u fit_, n « O�r1ELige WW Dm9w R fEOk a llRnaIID LIVE An Niy[ii"• °R� o rew" Fffto Alp RA-2- z 3 __„„_ o fEAyr flea h naE wHORIoH, ap�y� qyf ' - b Y N mlAaW�E mlamr arl4 faR _ A � --_-� 8 MOF xxu, J m m oR°.W O ladAMl a o6lRfae® � ule F — _ ` crlrb'fcaa OrL N eIR OOIIoxIrL GM1D ��R F f1/FN RA—I-2 „ kNi—WANd t _ aDgbw 1Alfaort a - - J�-=.XZV v > 36 East 31st Street,6th Floor New York,New York 10016 „.f„,Q, r_2 Tel: (212)244-0008 Fax: (212)244-0057 DEMAND CONTROL VENTILATION HOOD CONTROL PANEL SPECIFICATIONS: email:jkouveras@samtell.com - CONTROLS SHALL BE LISTED BY ETL (UL 608A) AND SHALL COMPLY WITH DEMAND VENTILATION SYSTEM TURNDOWN REQUIREMENTS OUTLINED IN IECC 403.2_8 (201b)- RELEASE DUCT TEMPERATURE SENSOR. - THE CONTROL ENCLOSURE SHALL BE NEMA 1 RATED AND LISTED FOR INSTALLATION INSIDE OF THE 1 CONCEPTUAL ISSUE 06-22-2022 KK EXHAUST HOOD UTILITY CABINET. THE CONTROL ENCLOSURE MAY BE CONSTRUCTED OF STAINLESS STEEL ELECTRICAL PANEL CONTROL 2 ELEVATIONS 06-30-2022 AS OR PAINTED STEEL 3 REV, CONCEPTUAL ISSUE 07-13-2022 KK - TEMPERATURE PROBE(S) LOCATED IN THE EXHAUST DUCT RISER(S) SHALL BE CONSTRUCTED OF �- 4 REV_ CONCEPTUAL ISSUE 08-09-2022 KK STAINLESS STEEL ` �. INTERFACE 5 REV. CONCEPTUAL ISSUE 09-12-2022 KK - A DIGITAL CONTROLLER SHALL BE PROVIDED TO ACTIVATE THE HOOD EXHAUST FANS DYNAMICALLY BASED 6 REV. CONCEPTUAL ISSUE 10-06-2022 KK 7 MEP SUBMISSION 10-25-2022 AO ON A FIXED DIFFERENTIAL BETWEEN THE AMBIENT AND DUCT TEMPERATURES SENSORS_ THIS FUNCTION SHALL MEET THE REQUIREMENTS OF IMC (07.1.1. 8 REV. CONCEPT DESIGN 12-12-2022 DE 9 DESIGN DEVELOPMENT 12-13-2022 DE - A DIGITAL CONTROLLER SHALL PROVIDE ADJUSTABLE HYSTERESIS SETTINGS TO PREVENT CYCLING OF THE ALARM INDICATING LCD SCREEN. 10 MEP SUBMISSION 12-23-2022 AO FANS AFTER THE COOKING APPLIANCES HAVE BEEN TURNED OFF AND/OR THE HEAT IN THE EXHAUST BUTTON FUNCTIONS VARY BY 1 MEP SUBMISSION 12-28-2022 AO SYSTEM IS REDUCED_ ooMROL PANEL, MODEL TYPE MEP SUBMISSION 01-03-2023 AO - A DIGITAL CONTROLLER SHALL PROVIDE AN ADJUSTABLE MINIMUM FAN RUN-TIME SETTING TO PREVENT FAN ROOM TEMPERATURE LCD MEP SUBMISSION 01-05-2023 AO CYCLING_ SEt1saR, INTERFACE, I OYSTER BAR CONCEPT 01-19-20231 DE OYSTER BAR REVISIONS 01-25-2023 KK STPICAL HOOD OOMWRDII PANEII/IN ILLA/PION O O - VARIABLE FREQUENCY DRIVES (VFDS) SHALL BE PROVIDED FOR FANS AS REQUIRED. THE DIGITAL OYSTER BAR REVISIONS 01-31-2023 DE CONTROLLER SHALL MODULATE THE VFDS BETWEEN A MINIMUM SETPOINT AND A MAXIMUM SETPOINT ON SEQUENCE OF OPERATIONS: [DOH TER LOBBY BAR MEP 02-10-2023 DE DEMAND. THE DUCT TEMPERATURE SENSOR INPUT(S) TO THE DIGITAL CONTROLLER SHALL BE USED TO THE HOOD CONTROL PANEL IS CAPABLE OF OPERATING IN ONE OR MORE OF THE FOLLOWING STATES AT ANY KGROUND UPDATE 02-24-2023 DE CALCULATE THE SPEED REFERENCE SIGNAL GIVEN TIME: — AUTOMATIC: THE SYSTEM OPERATES BASED ON THE DIFFERENTIAL BETWEEN ROOM TEMPERATURE AND TTE MEP SCHEDULES 02-27-2023 DE - THE VFD SPEED RANGE OF OPERATION SHALL BE FROM Oy TO 1OOP�FOR THE SYSTEM, WITH THE ACTUAL THE TEMPERATURE AT THE HOOD CAVITY OR EXHAUST DUCT COLLAR_ FANS ACTIVATE AT A SUBMITTAL 03-02-2023 DE MINIMUM SPEED SET AS REQUIRED TO MEET MINIMUM VENTILATION REQUIREMENTS, CONFIGURABLE TEMPERATURE DIFFERENTIAL THRESHOLD. DEPENDING ON THE JOB CONFIGURATION EACH FAO{ • WASH GAS RESET O SUBMITTAL UPDATE 03-09-2023 DflE ZONE CAN BE CONFIGURED AS STATIC OR DYNAMIC. THESE TERMS REFER TO WHETHER A VARIABLE DOCUMENTATION 03-10-2023 - AN INTERNAL ALGORITHM TO THE DIGITAL CONTROLLER SHALL MODULATE SUPPLY FAN VFD SPEED MOTOR (SUCH AS EC MOTORS OR VFD DRIVEN MOTORS) MODULATE WITH TEMPERATURE. IF THE PANEL IS PROPORTIONAL TO ALL EXHAUST FANS THAT ARE LOCATED IN THE SAME FAN GROUP AS THE SUPPLY FAN, EQUIPPED WITH VARIABLE SPEED FANS AND THE ZONE IS DEFINED AS "DYNAMIC", THESE WILL MODULATE O dam' PROJECT WITHIN A USER-DEFINED RANGE BASED ON THE TEMPERATURE DIFFERENTIAL PANELS EQUIPPED WITH © LIGHTS FANS O - THE SYSTEM SHALL OPERATE IN PREP MODE DURING LIGHT COOKING LOAD OR COOL DOWN MODE WHEN VARIABLE SPEED FANS AND A FAN ZONE DEFINED AS "STATIC", FANS WILL RUN AT A SET SPEED CT) SUFFICIENT HEAT REMAINS UNDERNEATH THE HOOD SYSTEM AFTER COOKING OPERATIONS HAVE CALCULATED FOR THE DRIVE, DEMAND CONTROL VENTILATION SYSTEMS ARE CAPABLE OF MODULATING CAT-P CONNECTION ON REVERSE. N COMPLETED. OPERATION DURING EITHER OF THESE PERIODS WILL DISABLE THE SUPPLY FANS AND PROVIDE EXHAUST AND MAKE UP AIR FAN SPEEDS PER THE REQUIREMENTS OUTLINED IN IECC 403.2.8. - CONNECTED TO HOOD CONTROL `- Q q* AN EXHAUST FAN SPEED THAT IS EQUAL TO THE MINIMUM VENTILATION REQUIREMENT. PANEL O O - A DIGITAL CONTROLLER SHALL DISABLE THE SUPPLY FAN(S), ACTIVATE THE EXHAUST FAN(S), ACTIVATE �NUAI THE SYSTEM OPERATES BASED ON HUMAN INPUT FROM AN HML Up) Z W 0 T THE APPLIANCE SHUNT TRIP, AND DISABLE AN ELECTRIC GAS VALVE AUTOMATICALLY WHEN FIRE CONDITION - Sr_.HEDULE A WEEKLY SCHEDULE CAN BE SET TO RUN FANS FOR A SPECIFIED PERIOD THROUGHOUT THE IS DETECTED ON A COVERED HOOD. DAY, THERE ARE THREE OCCUPIED TIMES PER DAY TO ALLOW FOR THE USER TO SET UP A TIME THAT IS O > F_ W WN CONTROL SHALL NOT OVERRIDE FAN OPERATION LOGIC AS REQUIRED BY CODE)), SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED OCCUPIED TIME, THE SYSTEM WILL RUN d O 1z - A DIGITAL CONTROLLER SHALL ALLOW FOR EXTERNAL BIAS FAN CONTROL VIA , CONTACT (EXTERNAL AT MODULATION MODE AND FOLLOW THE FAN PROCEDURE ALGORITHM BASED ON TEMPERATURE DURING TH6 0 „' z TIME. DURING UNOCCUPIED TIME, THE SYSTEM WILL HAVE AN EXTRA OFFSET TO PREVENT UNINTENDED MOUNTS IN STANDARD DOUBLE Z AN LCD INTERFACE SHALL BE PROVIDED WITH THE FOLLOWING FEATURES ACTIVATION OF THE SYSTEM DURING A TIME WHERE THE SYSTEM IS NOT BEING OCCUPIED. GANG JUNCTION BOX LLI A F Ld A. ON/OFF PUSH BUTTON FAN & LIGHT SWITCH ACTIVATION. - OTHER: THE SYSTEM OPERATES BASED ON THE INPUT FROM AN EXTERNAL SOURCE (DDC, BMS OR r� B. INTEGRATED GAS VALVE RESET FOR ELECTRONIC GAS VALVES (NO RESET RELAY REQUIRED). HARD-WIRED INTERLOCK). W V///) W O C. VFD FAULT DISPLAY WITH AUDIBLE & VISUAL ALARM NOTIFICATION. \ D. DUCT TEMPERATURE SENSOR FAILURE DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION, - fM- UPON ACTIVATION OF THE HOOD FIRE SUPPRESSION SYSTEM, THE EXHAUST FAN WILL COME ON OR W / d E. MIS-WIRED DUCT TEMPERATURE SENSOR DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION_ CONTINUE TO TO RUN, THE HOOD MAKEUP AIR WILL SHUTDOWN, AND A SIGNAL WILL BE SENT FOR .z F, A SINGLE LOW VOLTAGE CAT-5 RJ45 WIRING CONNECTION. ACTIVATING THE SHUNT TRIP BREAKER PROVIDED BY THE ELECTRICIAN. FUEL GAS WILL SHUT OFF VIA A G. AN ENERGY SAVINGS INDICATOR THAT UTILIZES MEASURED KWH FROM THE VFDS. MECHANICAL/ELECTRICAL GAS VALVE ACTUATED BY THE HOOD FIRE SUPPRESSION SYSTEM_ Q N W lu C W. ****** DATE: 1/19/23 �C�C�C*** ATTENTION ELECTRICIAN DWG.#: LOAD SIDE WIRING FOR EACH FAN MUST BE RUN P686264 SCALE DRAWN N.T.S. IN SEPERATE CONDUIT FROM EMS SYSTEM TO EACH gY;RDC-17 scALE: DRAWING s/a" = V-0. CAPTIVE AIRE FAN ON ROOF. MASTER DRAWING FABRICATION DRAWING DRAWING NUMBER SHEET NO. ■ 2 REVISIONS A FOR QUESTIONS, CALL THE PATENT NUMBERS I i Rce AC_PSp UNITED STATES)- US PATENT 7963830 B2. =04,17 AC (UNITED (CANADA)-CA PATENT 2820509. 2d PHONES AC-PSP ISLAND(CAN" -CA PATENT 2520330, j! p JW)723-3355 EMAIL-�g 70­ptWml-� C-i C=) E EXHAUSTPLE U HOOD CO FIG 0i SEE TEMP C-4 H000TAG MODEL MAW MAX APPLIANCE 1 00104 R%ER TOTAL HOOD -SENSOR DETAIL Aff4 SUP END TO FACTURER LENGTH COOKING TYPE TOT' *10TH (I)CFM �SP CFV coNsmucnoii END W- TE P DUTY CFM/FT EXH CF1IJ 00 No I UENG JHEIGHTI JU c-'I LL 'a -MI IMS I ALONE ALONE E 13 WHERE EXPOSED 8 ISND-�2 -F CAPTIVEAIRE 111 0' 1 MEDIUM 250 27M r I le 12 --0.80r 1.50- E 7gkAwoN tLL LISTED RECESSED ROUND LM ME FIRE HOOD IME M(s) I LIGHTISI I UTILITY CABINEITS) I AN --.5. HOOD TAG EFFNCY 0 7 01RE RE C SYSTEM Lfl_j NO TYPE Ott HEIGHT LENGTH MICRONS OTY TYPE LOCATION SIZE OU TYPE SIZE MODEL j QUANTITY PIPING 1 � ,111 3, WO 1 13 CAPIRATE SOLO FILTER a 20' is* 85%SEE FILTER SPEC 3 RECESSEDRouNo NO us fill 2e Mu 0-p-4 OPTION FIELD WRAPPER 18.00" HIGH FRONT,LEFT,RIGHT. '2 BACKSPLASH 74.06' HIGH X 132.00" LONG 430 ss vemcAL ��' 0 If 0 --A- K47 TAG POS LENGTH WIDTH HEIGHT NO — I*I—I LENG PT CFMI SP :E 11 UaA a 0_'6 _6e_ p 112 1�2e�- %161,in* 18* 12; MUA 1 12- 1 (3,161- -2e 1 44' 1 40 E 0 GREASE DUCT & CHIMNEY SPECIFICATIONS: 0 1. 16 >. - -77 11' E0LO0�TNe5'4'1"8QSN"-2-P P-F z �77 PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" w, ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" lit t3 W LM rinm UD UGHI� IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING gT'KO*Z oumur, MODEL "DW" CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. tzl DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER FIELD*RAPPOt 16.0e RGH THE MANUFACTURES INSTALLATION GUIDE. ME MOD OMWkS TABLE). PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER 011' EXIOUST ffsmmt, 01 MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" AITACHNO NATM H4040 PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12", DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE rh 2 3 ACCUMULATION IN HORIZONTAL RUNS. 2"C=SMO A"' �T 1 13 DO' E F HWV_ 36 East 31 st Street,6th Floor r W9*44L STANDOFF, 1014 New York,New York 10016 IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE Tel: (212)244-0008 SYSTEMS MODEL "DW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER IT 9 Tw ms-"mm Fax: (212)244-0057 OF 7KARCWW TO DUGT- INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. ENSM q1N." email:jkouverasgsamtell.com USTIBLE "-n 'MIALS %IN LOCA Co.RRE 0 CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF HVAC DISTRIBUTION NOTE E MAX. RELEASE LISTED, PRE-FABRICATED ROUND GREASE EXHAUST HIGH VELOCITY DIFFUSERS OR HVAC RETURNS 46� I CONCEPTUAL ISSUE 06-22-2022 KK 2 ELEVATIONS or:,-.3o-2022 TS_ DUCT TO REDUCE STATIC PRESSURE IN THE SHOULD NOT BE PLACED WITHIN TEN (10) FEET aIrIN SYSTEM, MINIMIZE INSTALLATION AND INSPECTION eAcKsmAm 74.W mw 3 REV. CONCEPTUAL ISSUE 07-13-2022 KK TIMES, AND ENSURE DUCT IS LIQUID TIGHT OF THE EXHAUST HOOD. PERFORATED DIFFUSERS X 02-W"LOW- TIMES, RECOMMENDED. REV. CONCEPTUAL ISSUE 08-09-2022 KK 74� 5 R-1y. CONCEPTUAL ISSUE 09-12-2022 KK 6.REV. CONCEPTUAL ISSUE 10-06-2022 KK 7 MEP SUBMISSION 10-25-2022 AID. VERIFY CEILING HEIGHT CUSTOMER APPROVAL TO MANUFACTURE: KA!W 8 REV.9 DESIGCONCEPT DEVELOPMENTNDESIGN 12-12-2022 DE 12-13-2022 DE APPROVED AS WYM 13 C MEP SUBMISSION 12-23-2022 AO APPROVED WM NO Excornom TAKEN 11 1 MEP SUBMISSION 12-28-2022 AO REVISE AND REWBUIT 0 2.MEP SUBMISSION 01-03-2023 AO SIGNATURE 1 MEP SUBMISSION 01-05-2023 AO HEIGHT REQUIRED TO VERIFY THAT HOOD FITS SPACE AND TO SIZE THE ENCLOSURE PANELS YOUR MILE LATE OYSTER BAR CONCEPT 01-19-2023 DE 15JOYSTER BAR REVISIONS 01-25-2023 KK OYSTER BAR REVISIONS 01-31-2023 DE HOOD CORNER FULL LENGTH SUPPLY PLENUM IyEdmoly VIE DRY,641&OA -2-P&-F 1 OYSTER LOBBY BAR MEP 02-10-2023 DE _A.1W BA (131 02- -2023 DE F ARE BY NF TALLER) (HARDWARE &.R) .'=Ao I BACKGROUND UPDATE ST 1 DINETTE MEP SCHEDULES 02-27-2023 DE 21DOH SUBMITTAL 03-02-2023 DE 211DOH SUBMITTAL UPDATE 03-09-2023 DE DOCUMENTATION 03-10 2023 DE 0 PROJECT MIT. J 0 RTD SENSOR INSTALLATION (IF NOT FACTORY INSTALLED) UJ W 4M ON SPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTER 71dr-MA3.1 cmmd to cmtm cW**% W WASSEMBLY INSTRUCTIONS ASSEM13LY INSTRUCTIONS ASSEMBLY INSTRUCTIONS THE CAPTRATE GREASE-STOP SOLO IS SINGLE-STAGE FILTER FEArUR4G > C) W >- SIGN IN NOTION HANGING ANGLE MUST BE SUPPORTED WITH 1/2'- 113 TPI HANGING ANGLE YUST BE SUPPORTED*1TH 1/2" - 13 TPI FLANGING ANGLE BE SUPPORTED*rrH 1/2*- ij TPI A UNIQUE S-BAFFLE DE A SLOTTED REAR BAFFLE DESIGN, W Z GRADE P (MINIMUM)ALL-THREAD, SANDWICH HANGING ANGLES GRADE 5(MINIMUM) ALL-THREAD_SANDWICH HANGING ANGLES GRADE 5 TO DELIVER EXCEPTIONAL FILTRATION EFMiENCy- LIM)ALL-THREAD, SANVCH FLANGING ANGLES GRADE 5 (MINIMUM) AND CEILING ANCHOR POINTS WITH 11T GRADE 5 NINIMLIO AND LING ANCHOR POINTS t[TH 1/2 GRADE 5(MINIMUM) FILTER IS STAINLESS STEEL CO N.AND StZED TO FIT INTO STANDARE A LLJ AND CEILING ANCHOR POINTS WITH 1/2 CEILING LAJ ,TEEL IX 2 13 GRADES STEEL FLAT WASHERS AND 1/2'- 13 TPI GRADE 5 STEEL FLAT WASHERS AND 1/2 - 13 TPI GRADED 2-INCH DEEP HOOD CKkN4EU(SrCW &A ud OAVI.W - T"''MUST USE DOUBLED HE)( (MINIMUM) HEX NUTS As smawk Vusr USE DOUBLED HEX (MINIMUM) HEX NUTS AS SHOWN, MUST USE DOUBLED HEX UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE T)SECURE THE TWO 0 Lu SHOWN,0D HANGING ANGLES AND NUT CONFIGURATION ABOVE COUNG ANCHORS-SINGLE HEX NUT CONFIGURATION ABOVE CORING ANCHORS. SINGLE HEX COMPONENTS WHEN ASSEMBLED_S WASHERS AND '/ NUTS AS N NIM ')T E AS� ANT IN NUT BENEATH HANG V NFL IN I Ilk Aww Nft ABOVE CEILING -W A 4' NUT BENEATH HANGING AN IS ACCEPTABLE FOR FULL ANGLE IS ACCEPTABLE FOR PSP GREASE EXTR�T�,N EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75XDF GREASE > 0 THREADS ' N aTH I X NUT, TO-TORQUE ALL HEX 4" LENGTH HANGING ANGLES ANGLE 114'OF EXPOSED -OF EXPOSED THREADS IEN HE R A 01W HEX NUT. TORQUE ALL HEX NUTS HANGING "WAIN 114 PARTICLES FIVE MICRONS IN SIZE,AND GREASE PARTICLES SEVEN MICRI:NS IN SIZE AND TO 57 FT-Ur- THREADS BENEATH iaF BENEATH HEX NUT.TORQUE ALL HEX NUTS TO 57 LARGER,WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHrS OF WATER GAUGE. 1 vd.0 J 0. TO 07 FT-LUS, FT-LBS_ CAPTRATE GREASE-STOP SOLO WAS TESTED TO AsTM STANDARD AsTIJ FZ19-05. -ionla Z z =uFAcruRER APPROVED FOR USE IN SOLID FUEL APPLICATIONS As A SPAR ARRESTER. SYSTEM DESIGN VERIFICATION (SDV) DTICIIINCYVS.PAMIC)A'DI\APTF R PRISRARDROPVS FJOW RATI MR Lu 0 UJI IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS 0 HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL TYPICALLY, THE SDV WILL BE Q*bd 4"" PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE_ DATE: i/19/23 ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE DWG.#: ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES eln 01 5686264 WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO SCALE RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND L__I_j I DRAWN N,T,S, BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY ,:RDC-17 THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES. E1101 SCALE: DRAWING 3/4' - 11*-0' CAPTIVE AIRE DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER,CAPTRATE FILTERS ARE BUILT 14 COMPLIANCE WITH:_ MASTER DRAWING 6 SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL E FPA f96. L ^ O FABRICATION DRAWING NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. N FSAN ULEDARD E(15TEc C)L ULC-S649_ DRAWING NUMBER SHEET NO. FS FAB1 .0 REVISIONS m FOR QUESTIONS, CALL THE PATENT NUMBERS """"'• 'y � NYC OHlee AC-PSP UNITED SPATES)-US PATENT 7963M B2 REGION 17 AC-PSP ALL(CANADA)-CA PAT"28205M AC-F5P ISLAND(CANIADA) -CA PATENT 2520330, m PHONE:1646)723-3386 11 —E1ANL:rc 70ceptivaollac0m � � UM HOOD FIG SEE TEMP CVt" r H000 MAX APPLIANCE DESIGN TOTAL TOTAL WOOD �1Y SENSOR DETAIL NO TAG MODEL ACfURER LENGTH COOKING TYPE DUTY OFM/FI EXH CFM SUPPLY CONSTRUCTION END TO ROW c� ,y TEMP WIDTH LEND HEIGHP DIA CFM VEL SP CFM END20 .. 1 13 6418 CAPTNENRE 11'0" I MEDIUM 250 2750 4" 16' 2760 1I566 -0.80Y 1050 430 SS ALONE ALONE � E S D-2-PSP-F D ERE EXPOSED Be JLJ -" G� E L LJ V.L.LISTEDRECESSEDRROUND LED m HOOD TAG EFFIC ENCY O 7 FIREF SYSTEM SYSTEM H C D ❑ ❑ ❑ ¢ I m E ... c NO TYPE OTY HEIGHT LENGTH J OTY TYPE LOCATION SIZE MICRONS TYPE SIZE MODEL/ OUANmY PIPING WEIGHT >_ 1 13 CAPTRATE SOLO FILTER 8 20` 15' 85S SEE FILTER SPEC 3 RECESSED ROUND NO NO "0 a L85 211' HOOD TAG OPTION 1 13 O FIELD WRAPPER I6.00' HIGH FRONT.LEFT,RIGHT � � � "`1 a 1!' tY 1Y BACKSPIASH 74A0' HIGH % 132D 12'0' LONG 430 SS VERTICAL 0 ® �IHOOOD TAG POS LENGTH WIM HEIGHT TYPE ,A70T1, LENG DU CFM SP v ,., m UA 12' 2H' 8 0.161' �. I �. 1 13 Front 132` 18` 6` UA 12` 2e- 6 0 0, 1I i�' UA 12' 28' 850 0.181' - o 1' GREASE DUCT & CHIMNEY SPECIFICATIONS: PLAN VIEW - HooD1 c, o PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" ]1' Ooo LONG 6418SN -2-PSP-F = z c 0 ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" ® a W IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING WIlOUa T FIXTURE AND LED UGH% CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" Q DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATION GUIDE. FIELDITRAPPM 1&00'HRR1 (SEE HOOD OPTIONS TAKE). Z m PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12 ON CENTER. PERIle MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" °"""A`"�' ATTAcHiNG RAn% < PER 12", HORIZONTAL RUNS MORE THAN 75 FT, CAN BE SLOPED 3/16" PER 12". "" ""°E, ���/ " HpOD STEf1 PERFQ+ATED PANEL. DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE � °�"�"HR� ACCUMULATION IN HORIZONTAL RUNS. 10 ATE BOLO 2 3 e 3 � '�""HOM d 36 East 31st Street,6th Floor r METAYL STANDOFF, +B' 1z, 1e' IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR York 10016 � Tel: (21 New York,New New UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW— 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER ITIs7WRESPONSIMUN Fax: (212)244-0057 OF T!E ARCIEIEOT/ 10 ENSUREi=5 HOOD CE N I 12Y'11RI, emal :l -ouveras samtell.com CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF HVAC DISTRIBUTION NOTE ODE RE ENrs, LISTED, PRE—FABRICATED ROUND GREASE EXHAUST HIGH VELOCITY DIFFUSERS OR HVAC RETURNS �� 1R CONCEPTUAL ISSUE 06-22-2022 KK DUCT TO REDUCE STATIC PRESSURE IN THE SHOULD NOT BE PLACED WITHIN TEN (10) FEET � " SOCIOPIISH74,W'Rom 3 REV. CONCEPTUAL ISSUE 07-13 2022 KK SYSTEM, MINIMIZE INSTALLATION AND INSPECTION OF THE EXHAUST HOOD, PERFORATED DIFFUSERS %InxD'1DNr_ 4 REV_ CONCEPTUAL ISSUE 08-09-2022 KK TIMES, AND ENSURE DUCT IS LIQUID TIGHT ARE RECOMMENDED. TCgo 5 REV. CONCEPTUAL ISSUE 09-12-2022 KK 6 REV. CONCEPTUAL ISSUE 10-06-2022 KK 7 MEP SUBMISSION 10-25-2022 AO EQUIPMENT VERIFY CEILING HEIGHT CUSTOMER APPROVAL TO MANUFACTURE: B REV. CONCEPT DESIGN 12-12-2022 DE UY MERS. 9 DESIGN DEVELOPMENT 12-13-2022 DE ' - APPROVED AS NDIm ❑ 0 MEP SUBMISSION 12-23-2022 AO APPrmym WITH ND ExcEPTON TAKEN ❑ 1 MEP SUBMISSION 12-28-2022 AO AND RE MOW OW ❑ 2 MEP SUBMISSION 01-03-2023 AO HEOHT REQUIRED TO VERIFY THAT HOOD FITS SPACE AND TO SIZE THE ENCLOSURESOATURE MEP SUBMISSION 01-05-2023 AO. PANELS Yp(,R TIRE DATE' OYSTER BAR CONCEPT 01-19-2023 DE OYSTER BAR REVISIONS 01-25-2023 KK HOOD CORNER FULL LENGTH dEdIvoy - - OYSTER BAR REVISIONS 01-31-2023 DE SUPPLY PLENUM viEW - - OYSTER LOBBY BAR MEP 02-10-2023 DE r (HARD ARE BY NSTALLER) Wce e� (f1AR ARE BY I ALLER) p,t�s VIA >REa,lez pea �w Ia WM (HARD E BY INSTALLER) BACKGROUND UPDATE 02-24-2023 DE TDINETTE MEP SCHEDULES 02-27-2023 DE paL pm DOH SUBMITTAL 03-02-2023 DE + � 1 DOH SUBMITTAL UPDATE 03-09-2023 DE Rom`a Ham`°`S R.-E E`"n°C" N MEP DOCUMENTATION 03-10-2023 DE pm lu-THEAq pm Au- pm Au�AG PROJECT (n wR Roao> I�IR+oel 1w�Fr'u' � � RTD SENSOR INSTALLATION (IF NOT FACTORY INSTALLED) 1n Z W �• t -R°DtalµiIR Eae�v a t(Ii ICAO 'wa a {YAI1 L ASSEMBLY INSTRUCTIONS ASSEMBLY�INSTRUC110NS ASSEMBLY INSTRUCTIONS SPECIFICATION. CAPTRATE G°ITEASE-STOP S8LO FILTER RT- SE>Qalst�wt cWed to lx 0 caw � Q' W � LLI � HANGING ANGLE MUST BE SUPPORTED WITH 1/2"- 13 TPI HANGING ANGLE UST BE SUPPORTED WrrH 1/2' - 13 TPI THE UNIQUE STE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER BAFFLE E II0 In 3 N 0- � O li HA NG ANGLE MUST BE SUPPORTED WITH 1/2'- 13 TPI A UNIQUE S-XCEP' DESIGN N ION,IEFFaEN WITH A SLOTTED REAR BAFFLE DESIGN. a GRADE P (MINIMUM) ALL-THREAD, SANDWICH HANGING ANGLES GRADE 8(MINNU ) ULL-THREAD.SANDWICH HANGING ANGLES GRADE 6 (MINIMUM)ALL-THREAD. SANDWICH HANGING ANa.ES TO EXCEPT' FILTRATION EFFIgENCt'. Z W Z AND CEILING ANCHOR POINTS WITH 1/2"GRADE 5 (MINIMUM) AND CEILING ANCHOR POINTS WITH 1/2"GRADE 5(MINIMUM) AND CEILING ANCHOR POINTS WITS 1/2 GRADE B(MINIMUM) FILTER IS STAINLESS STEEL CONSTRUCTION.AND SIZED TO FIT INTO STANDARD E,u„„ L-I 5 n STEEL FLAT WASHERS AND 1/2-- 13 TPI GRADE S STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADES STEEL FLAT WASHERS AND 1/2. 13 TPI GRADE 6 2-INCH DEEP HOOD CHANNELS. ����� � (MINIMUM) HEX NUTS AS SHOWN, MUST USE DOUBLED HEX (MINIMUM) HEX NUTS AS SHOWN.MUST USE DOUBLED HEX (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX UkN(trs� SHALL INCLUDE STAIN�LESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO N bv UT CONFIGURATION BENEATH HOOD HANGING ANGLES AND NUT CONFIGURATION ABOVE CEILING ANCHORS.SINGLE HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX COME IENIS WHEN ASSEMBLED_ 0 rl/ W cc ABOVE CEILING ANCHORS.MAINTAIN 1/4`OF EXPOSED NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL NUT BENEATH HANGqNG ANGLE IS ACCEPTABLE FOR PSP GREASE E7RRACTIpN EFFICIENCY PERFORMANCE SHALL.REMOVE AT LEAST 7SA OF CREASE O THREADS BENEATH BOTTOM HEX NUT,TORQUE ALL HEX NUTS LENGTH HANGING ANGLES MAINTAIN 1/4'OF EXPOSED HANGING ANGL�ES1 A4UNPNN 1/4"OF EXPOSED THREADS pARTICLES FIVE MICRONS IN SIZE,AND X GREASE PARTICLES SEVEN MICRONS N SIZE AND °ij W Cl j TO 57 FT-lBS_ THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS BENEATH BOTIUM HEX NUT.TORQUE ALL HEX NUTS TO 57 LARD�A CORRESPONDING P RE DROP NOT TO EXCEED 1.0 INCHIS OF WATER GAUGE a TO 7 FT-LBS. 6 FT-LBS_ �}1E CAPITL1Tf GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2379-05, MAN UFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARL ARRESTER. - Iw Z SYSTEM DESIGN VERIFICATION (SDV 14T1C11\CYVS.P I RCICIT D1%d 'fLR PR SLRet DROP l51'l WRATI Taw Y/ u u10-0M-r : �x � W IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS N W HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL TYPICALLY, THE SDV WILL BE „"��tlip 'n PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE. 5 l r V t. DATE. 1/19/23 ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES DWG.x: WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO TM*0 ""°r 5686264 SCALE RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND H DRAWN�C_17 N.T.S. BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY e,: THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES. SCALE: DRAWING ' P,,RTNLRI)]Nu P.RiTT: 1lAWR.iTI.(el?fI 3/4' = V-0' CAPTIVE AIRE DURING THE SDV. CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER.CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITI+;- MASTER DRAWING FABRICATION DRAWING SHOULD A RETURN TRIP BE.REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL BE NFPA f9e / /� / yv NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. u15.F STANOAR�R/i2 C�,'yl�y#fry��j IIIIIIYJ�/\J� `ILya TNT_MECH.CADE (IIAC). ULC-S649_ DRAWING NUMBER SHEET NO. 1FS I ■® Interstate Fire & Safety Equipment Co., Inc. a leader in Fire Protection since 1951 914. 937.6100 203.531.1333 TO: Town of Southold 54375 Main Road PO Box 1179 Southold NY 11971-0959 RE: Silver Sands Motel 1400 Silvermere Road Greenport NY 11944 FIRE SYSTEM NOTES: UL LISTING '01 AN"m L8, 1. SYSTEM SHALL BE PRE-ENGINEERED THE R-102 RESTAURANT FIRE SUPPRESSION SYSTEM HAS BEEN TESTED AND IS au - --� 2. SYSTEM SHALL BE MANUFACTURED BY ANSUL INC LISTED BY UNDERWRITERS LABORATORIES, INC. AS A PRE-ENGINEERED SYSTEM. THE SYSTEM IS IN COMPLIANCE WITH UL TEST STANDARD 300. THESE TESTS REQUIRE EXTINGUISHMENT OF FIRES WHICH ARE INITIATED IN DEEP 3. ANSUL SYSTEMS HAVE THE FOLLOWING LISTINGS AND APPROVALS: FAT FRYERS, RANGES, GRIDDLES, CHAR-BROILERS, WOKS, UPRIGHT BROILERS, CHAIN-BROILERS, FILTERS, PLENUM CHAMBERS, HOODS, AND DUCTS AFTER UNDERWRITERS LABORATORIES INC, UL 300 / UL 1254, UL EX 3740 PRE-LOADING EACH APPLIANCE WITH A PRESCRIBED AMOUNT OF COOKING GREASE. EACH FIRE IS ALLOWED TO PROGRESS TO MAXIMUM INTENSITY BEFORE 4. SYSTEM TEMPERATURE LIMITATIONS - 32F MIN / 120F MAX THE FIRE SUPPRESSION SYSTEM IS ACTUATED. 5. INSTALLATION REQUIREMENTS, NOZZLE LIMITATIONS AND DESIGN CRITERIA SHALL SYSTEM APPROVALS COMPLY WITH THE ANSUL TECHNICAL MANUAL AND ALL ADDENDUMS AS PUBLISHED BY ANSUL INC. UL EX3740 ULC EX3470 6. PIPE AND FITTINGS SHALL BE SCHEDULE NTP, 40 BLACK, CHROME PLATED OR COA #5663 (NYC) STAINLESS. GALVANIZED PIPE SHALL NOT BE USED. TANK AND CARTRIDGE REQUIREMENTS Once the hazard analysis is completed and the total nozzle flow 7. ALL REQUIRED ELECTRICAL WORK SHALL BE PERFORMED BY OTHERS AND IS NOT INCLUDED numbers are established, the quantity and size of agent tanks and ON THIS SHOP DRAWING. cartridges needed to supply the nozzles with the proper volumes of agent at the proper flow rates can be determined. For cartridges used in the regulated release mechanism, flow capacities. tank 8. ALL REQUIRED PLUMBING WORK BE PERFORMED BY OTHERS AND IS NOT INCLUDED ON THIS quantities and sizes, and regulated release cartridge options are 1 SHOP DRAWING given in the table below. Total Quantity and Regulated Release } Flow Size of Cartridge Options Numbers' Tanks Nitrogen Carbon Dioxide • FRYERS TO HAVE HIGH LIMIT CONTROL TO SHUT OFF FUEL AT 425 DEGREES (BY OTHERS) 1 - 5 (1) 1.5 Gallon LT-20-R 101-10 FRYERS TO BE SEPARATED FROM ANY ADJACENT OPEN FLAMED COOKING EQUIPMENT BY AT 6- 11 (1) 3.0 Gallon LT-30-R 101-20 11 - 16 (1) 1.5 Gallon Double 101-30 • LEAST 16" . IN LIEU OF SEPARATION DISTANCE, A 16" HIGH 1/8" THICK STEEL BAFFLE (1) 3.0 Gallon MUST BE PERMANENTLY ATTACHED TO THE LONGER OF THE TWO COOKING APPLIANCES MAY BE 16-22 (2)3.0 Gallon Double 101-30" USED. THE BAFFLE SHALL EXTEND TO THE FULL DEPTH OF THE COOKING EQUIPMENT IT IS When one or more regulated actuators are used, the following ATTACHED. (BY OTHERS) tank and cartridge combinations apply for each regulated actuator: Regulated Actuator Regulated Actuator • DETECTORS SHALL BE LOCATED OVER EVER PIECE OF EQUIPMENT. Tank(s) Cartridge (1) 1.5 Gallon LT-20-R or 101-10 • THE SYSTEM INSTALLED AS PER MANUFACTURERS SPECS AND THE AHJ . (1) 3.0 Gallon LT-30-R or 101-20 (1) 1.5 Gallon and LT-A-101-30 or 101-30" or • THE SYSTEM HAS BEEN INSTALLED AS PER UL-300. (1) 3.0 Gallon double tank (2) 3.0 Gallon LT A-101-30 or 101-30"' or double tank • THE FOLLOWING FUNCTIONS TO OPERATE UPON SYSTEM DISCHARGE: • SUPPLY AIR DAMPER CLOSES INTERSTATE FIRE & SAFETY EQUIPMENT CO. INC. • GAS FUEL SHUTS OFF IN KITCHEN / 75 CALVERT STREET I 1� • EXHAUST FAN REMAINS ON HARRISON, NY 105281�v1 U • ELECTRIC FUEL SHUT THE SILVER SANDS MOTEL r • FIRE ALARM SHALL ACTIVATE IF ONE IS INSTALLED IN BUILDING. SYSTEM SHALL MEET SUFFOLK COUNTY FIRE 1400 SILVERMERE ROAD PREVENTION ORDINANCE, NFPA 17A, NFPA 96, jo GREENPORT, NY 11944 • ALL FUEL SOURCES ARE GAS UNLESS OTHERWISE NOTED. NYS BUILDING, FIRE & MECHNICAL CODES (914) 937-6100 SIZE DWG NO DWG REV +Y/ Z O •'G _ FIRE SYSTEM 2 SIGN0.NRE SCALE AS NOTED 1 7/31/2023 SHEET 1 OF 7 0t A�SUL� FUSIBLE LINK TEMPERATURE SELECTION SHALL BE PER THE ANSUL INSTALLATION MANUAL RECOMMENDATIONS FES ELECTRICAL SHUT DOWN (IF REQUIRED) - BY OTHERS CONNECTION TO MAKE UP AIR FAN, SHUT DOWN UPON Flmu ACTIVATION (IF REQUIRED CONNECTION BY OTHERS) CONNECTION TO HORN STROBE / AUDIBLE DEVICE OR F.A.C.P. ACTIVATES UPON ALL SYSTEM PIPING SHALL BE 11 -0" A SYSTEM DISCHARGE (SUPPLIED & INSTALLED BY OTHERS) 3/8" BLACK SCHEDULE 40 I 18" DIA I DUCT I ALL ELECTRIC APPLIANCES _ I _ I I 2W 'r I I -------- ---------- ----- ----- ------ ------ REGULATED RELEASE zz 360 360 360� 360 450 (1) 3-GALLON TANK 101-20 CART I IN 1 L m (LOCATED IN END CAP OF HOOD) 3 GAL N I m I I I 1F 1N 1F I I 36"-40" 29 40"-4S" I 13"-16" I I 42"-48" ELECTRIC IF ° DISCONNECT f (BY OTHERS) 2-BURNER PASTA PLAQUE 2-BURNER FRYER RADIANT COOKER ANTHANOR RADIANT 16"x19" REMOTE PULL STATION 12"x24" 12"x16" COOK TOP 12"x24" SHALL BE INSTALLED 42" - 48" ABOVE THE FINISHED ANSUL R102 - 3 GALLON SYSTEM 36"x16" FLOOR AT A DISTANCE OF NOT MORE THAN 20FT FROM THE HOOD. IT SHALL BE INSTALLED IN THE PATH OF TANK 1 USES: 9 of 11 POINTS EGRESS AND REQUIRE A MAXIMUM FORCE OF 40 LBS AND A MAXIMUM MOVEMENT OF 14" FOR ACTUATION NOZZLE SUMMARY TABLE SYSTEM PIPING LIMITATIONS CLASS K WET CHEMICAL EXTINGUISHER HAZARD 9TY NOZZLE PTS TOTAL 3 GALLON (per c tinder SHALL BE INSTALLED NO MORE THAN 60" ABOVE THE �p cylinder) FINISHED FLOOR WITHIN 30 FT FROM THE HAZARD. TANK 1 - 3 GALLON TANK - 11 FLOW POINTS MAX 2-BURNER 2 1F 1 2 DUCT PLENUM APPLIANCE PRE-ENGINEERED SYSTEM SHOP DRAWING ONLYSCALE: 1/4" = V -0" COOK TOP 1 1N 1 1 REQUIREMENTS SUPPLY BRANCH BRANCH BRANCH INTERSTATE FIRE & SAFETY. EQUIPMENT CO. INC. FRYER 1 290 2 2 PIPE SIZE 3/811 3/811 3/8if 3/8 75 CALVERT STREET HARRISON, NY 10528 PLENUM 2 1N 1 2 MAXIMUM LENGTH 40 FT 8 FT 4 FT 12 FT � THE SILVER SANDS MOTEL MAXIMUM RISE 6 FT 4 FT 2 FT 2 FT DUCT 1 2w 2 2 1400 SILVERMERE ROAD MAX 90 ELBOWS 9 4 4 6 GREENPORT, NY 11944 TOTAL 9 MAX TEES 1 2 2 4 (914) 937-6100 SIZE DWG NO DWG REV FIRE SYSTEM 2 MAX FLOW POINTS 11 4 2 4 SIWTUQE SCALE AS NOTED 1 7/31/2023 1 SHEET 2 OF 7 PIPING ISOMETRIC - TANK #1 N . T . S 2W 12" 8" 10" H G F 6" D C 21" 25" 17" 25" 17" 22" B A 6" 12" 12" E 12" 12" 6" 1N 1N :l ANSUL. 24" 24" 24" 36" 3-GAL 1F 1N 1F 290 ANSUL R102 - 3 GALLON SYSTEM TANK 1 - 11 POINTS MAX TANK 1 USES : 9 of 11 POINTS START END FT PIPE SIZE NOZZLE QTY FLOW PTS A TANKS 1 & 2 END OF SUPPLY LINE H 13 . 1 3/8" B SUPPLY LINE PLENUM NOZZLE 0 .5 3/8" 1N 1 1 C SUPPLY LINE FRYER NOZZLE 4 . 0 3/8" 290 1 2 D SUPPLY LINE 2-BURNER NOZZLE 3 . 0 3/8" 1F 1 1 E SUPPLY LINE DUCT NOZZLE 0 . 5 3/8" 2W 1 2 F SUPPLY LINE COOK TOP NOZZLE 3. 0 3/8" 1N 1 1 G SUPPLY LINE 2-BURNER NOZZLE 3. 0 3/8" 1F 1 1 H SUPPLY LINE PLENUM NOZZLE 0 . 5 3/8" 1N 1 1 27 . 6 1 7 .0 1 9. 0 INTERSTATE FIRE & SAFETY EQUIPMENT CO. INC. 75 CALVERT STREET HARRISON, NY 10528 ALL PIPE LENGTHS ARE ESTIMATES BASED ON SKETCHES AND / OR ARCHITECTURAL DRAWINGS THE SILVER SANDS MOTEL FIELD CONDITIONS MAY REQUIRE ADJUSTMENT TO THESE PIPE LENGTHS / MEASUREMENTS 1400 SILVERMERE ROAD GREENPORT, NY 11944 AT NO POINT SHALL THE TOTAL PIPE LENGTHS or PIPE VOLUMES BE ALLOWED TO EXCEED THE MAXIMUM LIMITATIONS (914) 937-6100 SIZE DWG NO DWG REV INSTALLER SHALL ENSURE THAT ALL MINIMUM AND MAXIMUM PIPE LENGTHS, PIPE VOLUMES AND PIPE FITTING ALLOWANCES ARE MET AT TIME OF INSTALLATION 5IGtL1TURE FIRE SYSTEM 2 SCALE AS NOTED 1 7/31/2023 SHEET 3 OF 7 I I II II I I I II I I I I I I I III III I I I I � � I I I Ii---------------- � I _ 1 Ll I U I I I I � l F 1I I I Elf I J [---, I I w I I I I \ I p LJ I I I L I = r-i I DO Li- I I I w I I elf Li II w I I o- I ��� i it FRz --- ---- REMOTE PULL J L___ STATION w \ 7ANUL 3-GALLON TANK & CONTROLS INTERSTATE FIRE & SAFETY EQUIPMENT CO. INC. NOTE : PULL STATION IS LESS THAN 10FT FROM 75 CALVERT STREET HARRISON, NY 10528 HAZARD BUT IS IN THE BEST LOCATION FOR THE SILVER SANDS MOTEL THIS KITCHEN AND ON THE PATH OF EGRESS FLOOR PLAN iio 1400 SILVERMERE ROAD GREENPORT, NY 11944 NOT TO SCALE (914) 937-6100 SIZE DWG NO DWG REV FIRE SYSTEM 2 SIGNATIIXE SCALE AS NOTED 7/31/2023 SHEET 4 OF 7 HORIZONTAL PROTECTION — OPTION 1 DUCT 1 N NOZZLE SINGLE BANK PROTECTION PROTECTION ► One 1 N nozzle will protect 10 linear feet (3.0 m) of single filter bank plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (50 to 102 mm) from the face of the filter, centered between the - filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-152 mm) from the end of the hood to 2-8 IN. the tipof the nozzle. See Figure 4-9. (51 -203 mm) } 9 I FIGURE 4-1 ► 2-4 IN. 10 FT (3.0 m) OW173 (50-12 mm) MAXIMUM 2. In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (203 mm) maximum, to a point just beyond the damper assembly that will not interfere with the damper. Exceeding the maximum of 8 in. (203 mm) in this way will not void the 000201 UL listing of the system. 3. Previously listed three flow number and five flow number duct protection detailed in earlier published manual (Part No. 418087-06) can also still be utilized. DUCT SIZES UP TO 50 IN. (1270 mm) 000202 PERIMETER/ 16 IN. (406 mm) DIAMETER a • One 1 W nozzle = one flow number �{ • 50 in. (1270 mm) perimeter maximum • 16 in. (406 mm) diameter maximum DUCT SIZES UP TO 100 IN. (2540 mm) PERIMETER/ 32 IN. (812 mm) DIAMETER - One 2W nozzle = two flow numbers • 100 in. (2540 mm) perimeter maximum • 32 in. (812 mm) diameter maximum The chart below shows the maximum protection available from each duct nozzle. 3.0 Gallon 1.5 Gallon Description System System 2W Nozzle Maximum Maximum 100 in. (2540 mm) 100 in. (2540 mm) Perimeter Perimeter 1 W Nozzle Maximum Maximum INTERSTATE FIRE & SAFETY EQUIPMENT CO. INC. 75 CALVERT STREET 50 in. (1270 mm) 50 in. (1270 mm) HARRISON, NY 10528 Perimeter Perimeter THE SILVER SANDS MOTEL 1400 SILVERMERE ROAD GREENPORT, NY 11944 (914) 937-6100 SIZE DWG NO DWG REV FIRE SYSTEM 2 F�- SCALE AS NOTED I 7/31/2023 SHEET 5 OF 7 Maximum Area Dimensions—Single Nozzle Fryer Protection(Continued) Range Protection IF (1-Flow) Nozzle (With or Without Back Griddle Protection 1 N (1-Flow) Nozzle — High Proximity Max.size Shelf/Obstruction) Application Max.size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Frye: Location Single and multiple burner ranges can be protected using a High Proximity Application: 35 in. to 40 in. (889 to 1016 mm) ►14.5 in.x16.5in. 14.5 in.x 26.5 in. 290 16 in.to21in, See Figure4-17 1 F nozzle. The nozzle is stamped with 1 F indicating that it is a ►(368 mm x 419 mm) (368 mm x 673 mm) (406 to 533 mm) ► above the cooking surface. 19.5 in.x 19 in. 19.5 in,x 25 H in. 290 13 in.to 16 in. See Figure 4-17 one-flow nozzle and must be counted as one flow number. ►(495mmx482mm) (495mmx644mm) (330to406mm) When using the 1 F nozzle for range protection with or without back This high proximity application uses the 1 N nozzle. 19.5 in.x 19 in. 19.5 in.x253/8in. 3N See Figure4-18 See Figure4-18 shelf or other similarly sized obstruction, the maximum length of ►(495mmx482mm) (495mmx644mm) the burner rates being protected must not exceed 28 in. 711 The nozzle is stamped with 1 N indicating this is a one-flow 18 in.x18in. 18 in,x 27 3/4 in. 3N 25 in.to35in. See Figure4-19 g g p ( ►(457 mm x 457 mm) (457 mm x 704 mm) (635 mm to 889 mm) mm) and the maximum area of the burner grates must not exceed nozzle and must be counted as one flow number. 336 in.2 (21677 mm2). See Figure 4-37 for nozzle location details. ` One 1 N nozzle will protect a maximum cooking area of 1080 in.2 = - I . IF NOZZLE (69677 mm2) with the maximum longest side of 36 in. (914 mm). SHELF OR OTHER SIMILARLY SIZED OBSTRUCTION CAN OVERHANG BURNER(S) 'aF 1 I i' ; BY A MAXIMUM OF 11 IN. (279 mm) TOP� ' 7 I NOZZLE LOCATION 0-2 IN. (0-50 mm) ! l INSIDE PERIMETER I 40 I IN. FAti'ERYviTHO:.�iDRIPBOARD FR*'ERNaITHDRIP�QARD I 18 IN. —► OF COOKING SURFACE 1 (1016 mm) ++ 290 NOZZLE TIP P0317-9.1 D QV'ER THE N IDPOINT O;THE HAZARD A5EA t 3 IN, `� RIGHT-TO-LEFT WX% f (76 mm}FRMI TH MiDFQINr ALC'd THE LQNGES'SIDE v^ THE HnZARD ntiJ= ?'' CLN R LSE MAXIMUM AIM (457 mm) I"i.i8 rani FRQ,IS?Hf MIDPOINTALOV3 THE SHOW,EST SIDE OF THE HAZARD 40-48 IN. POINT MINIMUM I l HEIGHT ArdDX'"ED A THE+,",1DP�"l70f THE Cv✓3i:tVGAREA. FRYER W1TiiQUT OHi=?OA.RD FRYER WITH DRiP80ARD (1016- 1219 mm) I / I NOTE:3'.37�ETI?t,?JSTBELOOA7ED;kiTHttf'HEP£R(49E ERQFiH=SJRFACE OF IN FIGURE 4.17 AREA W HNTHEFROWHA',FOFTHEFRYPeTA'IDM!EDATTHECFJN17-R l I NOZZLE TIP " " FIGURE 441 34IN'.(M mm)N WRAUNI DIAGONAL DISTANCE BE MEEN tr_ZZl.E AND i 135 IN. (889 mm) CENTER OFHAZARDnREA MINIMUM I I HEIGHT;, r>' > EDGE `' 21n:534rms -' 14 IN. I i I I O F 1 N �`� ' ! g�INlrAUt+ (355 mm) OF �� ( i I I NOZZLE TIP s y NOSE` W MAXIMUM COOKING ' . HEIGHT 12 IN. f 14 IN. 355 mm) SURFACE ( I (304 mm)MAXIMUM FRONT TO REAR MAXIMUM , CENTERLINE 1F NOZZLE LOCATED OVER FRONT EDGE OF BURNER GRATE AND ORIENTED FRYER W.T.OUT DRIMARD FRYER'iITrIDRIP6OkRD SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER GRATE FRONT TO REAR 3NNOZZ.£TR ACEAN AIVEDT,HEaEA CENTER WITHIN PERIMETERGARE,OF C.^rCI<JNG SURFACE ANDAttiED TO THE CENTER OF THE COO SING AREA, CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE. FIGURE 4-18 INTERSTATE FIRE & SAFETY EQUIPMENT CO. INC. 75 CALVERT STREET HARRISON, NY 10528 1 THE SILVER SANDS MOTEL 1 1400 SILVERMERE ROAD J GREENPORT, NY 11944 (914) 937-6100 SIZE DWG NO DWG REV FIRE SYSTEM 2 SIGNATURE SCALE AS NOTED 1 7/31/2023 SHEET 6 OF 7 SYSTEM SHALL UTILIZE GLOBE ML®Tm FUSIBLE LINKS FOR AUTOMATIC SYSTEM ACTIVATION. FUSIBLE LINKS ARE DESIGNED TO SEPARATE AT SPECIFIC TEMPERATURES, RELEASING TENSION FROM THE FUSIBLE LINK DETECTION LINE AND CAUSING SYSTEM ACTUATION. CORRECT FUSIBLE LINK SELECTION IS AN ESSENTIAL ELEMENT IN THE DESIGN OF ANY FIRE SUPPRESSION SYSTEM. AFTER PERFORMING A TEMPERATURE STUDY TO DETERMINE THE MAXIMUM AMBIENT TEMPERATURE AT THE FUSIBLE LINK LOCATION, THE CORRECT FUSIBLE LINK SHOULD BE SELECTED FROM THE FOLLOWING CHART: TEMPERATURE RATING MW AVEI91ff TEMPERATURE LOAD RATIAG OF °C OF °C MIN mx 1350 570 1000 380 10 LBS 40 LBS 1650 74° 1000 380 10 LBS 40 LBS 2120 100° 1500 w 10 LBS 40 LBS 2.25" 280° 1380 MID 107° 10 LBS 40 LBS GLOBE® 360° 182° 300° 1490 10 LBS 40 LBS ML?&@ 4500 1 2320 3750 1910 10 LBS 40 LBS Made in USA 500° 1 26W 4300 1 217° 10 LBS 40 LBS O • UL LISTED TO UL 33, HEAT RESPONSIVE LINKS FOR FIRE PROTECTION SERVICE • DATE STAMPED WITH YEAR OF MANUFACTURE .66" �.79" ► • CORROSION RESISTANT CONSTRUCTION • STAINLESS STEEL COMPONENTS — • FLEXIBLE EYE HOOK CONNECTION • 21/64" MOUNTING HOLE DIAMETER • LISTED FOR USE IN ALL FIRE PROTECTION SYSTEMS Y a ALL PENETRATIONS TO THE HOOD SHALL BE SEALED MIC ROSWITCH DIAGRAM WITH AN APPROVED QUICK SEAL DEVICE COMMON (RED) GIKE LOCK GASKET LOCK WASHER / WASHER COMPRESSION `-/ NUT NUT ADAPTOR / GASKET N•0 /r NUT BLACK SEAL �—ADAPTOR 21A 125/250 VAC (BLACK) � BODY i I ' 2 HP 250 VAC N.C. INTERSTATE FIRE & SAFETY EQUIPMENT CO. INC. 1 HP 125 VAC 0 (BROWN) 75 CALVERT STREET HARRISON, NY 10528 / PIPE / THE SILVER SANDS MOTEL PIPE 1400 SILVERMERE ROAD DUCT PIPE _ r' DUCT GREENPORT, NY 11944 (914) 937-6100 SIZE DWG NO DWG REV FIRE SYSTEM 2 SIGNANRE SCALE AS NOTED 7/31/2023 SHEET 7 ]OF 7 TABLE OF CONTENTS UL EX.3470 ULC CEx747 Page 1 4-1-06 REV.8 r- SECTION PAGES S C 1 PAGES I. GENERAL INFORMATION 1-1 —1.2 III. SYSTEM COMPONENTS 3-1 —3-12 DESIGN AND APPLICATION 1-1 (Continued) UL LISTING 1.1 REMOTE MANUAL PULL STATION 3-9 MECHANICAL GAS VALVES 3-9 DEFINITION OF TERMS 1-1 —1-2 ELECTRICAL GAS VALVES 3-10 If. SYSTEM DESCRIPTION 2-1 —2-2 MANUAL RESET RELAY 3-10 TOTAL SYSTEM 2-1 ELECTRICAL SWITCHES 3-10 Single-Tank 2-1 ALARM INITIATING SWITCH 3-10 Double-Tank 2-1 REGULATOR TEST KIT 3-11 Multiple-Tank 2-2 FUSIBLE LINK 3-11 III. SYSTEM COMPONENTS 3-1 —3-12 MAXIMUM REGISTERING 3-11 THERMOMETER EXTINGUISHING AGENT 3-1 HOSEIGROMMET PACKAGE 3-11 "ANSUL AUTOMAN"REGULATED 3-1 BURSTING DISC 3-11 RELEASE ASSEMBLY NOZZLE AIMING DEVICE 3-11 (MECHANICAL) "ANSUL AUTOMAN"REGULATED 3-1 STAINLESS STEEL ACTUATOR HOSE 3 1 1 RELEASE ASSEMBLY IV. SYSTEM DESIGN 4-1 —4-60 (ELECTRICAL) NOZZLE PLACEMENT 4.1 —4-31 REMOTE MECHANICAL RELEASE 3-2 REQUIREMENTS SINGLE TANK ENCLOSURE 3-2 Duct Protection 4-1 -4-3 ASSEMBLY Transition Protection 4-4 RED PAINTED BRACKET ASSEMBLY 3-2 Electrostatic Precipitator 4-4 REGULATED ACTUATOR 3 2 Protection ASSEMBLY Plenum Protection 4-5-4-6 Appliance Protection AGENT TANK ASSEMBLY 3-3 Fryer—Single Nozzle Protection 4-7-4-9 OEM RELEASE/BRACKET 3-3 Multiple Nozzle Fryer Protection— 4.10—4-12 ASSEMBLY(FOR OEM Tilt Skillet/Braising Pan 4-12 IN-CABINET USE ONLY) Range Protection 4.13—4-16 Griddle Protection 4-17—4-21 OEM REGULATED ACTUATOR 3-3 Chain Broiler Protection 4-22 ASSEMBLY Overhead Chain Broiler Protection 4-22—4-23 TWO TANK ENCLOSURE ASSEMBLY 3-3 Upright/Salamander Broiler 4-23 24 VDC REGULATED RELEASE 3-4 Protection ASSEMBLY Gas-Radiant/Electric Char-Broiler 4-24 Protection ADDITIONAL SHIPPING ASSEMBLY 3-4 Lava-Rock(Ceramic)Char-Broiler 4.25 GAS CARTRIDGES 3-5 Protection Natural Charcoal Broiler Protection 4-25 NOZZLES 3-5 Alternate Ceramic/Natural 4-26 SILICONE LUBRICANT 3-5 Charcoal Char-Broiler Protection SWIVEL ADAPTOR 3-6 Wood Fueled Char-Broiler Protection 4-26 Wok Protection 4-27 RUBBER BLOW-OFF CAP 3-6 Nozzle Application Chart 4-28—4-31 METAL BLOW-OFF CAP 3-6 Specific Application by Model 4-32—4-38 CB METAL BLOW-OFF CAP 3-6 Overlapping Nozzle Coverage 4-39—4-42 FOR CHAIN BROILERS TANK AND CARTRIDGE 4-43 CONDUIT OFFSET ASSEMBLY 3-6 REQUIREMENTS "QUIK SEAL"ADAPTOR 3 6 ACTUATION AND EXPELLANT 4.43—4.45 GAS LINE REQUIREMENTS "COMPRESSION-SEAL"ADAPTOR 3-7 DISTRIBUTION PIPING 4-45—4-53 "HOOD SEAL"ADAPTOR 3-7 REQUIREMENTS ASSEMBLY General Piping Requirements 4-45 DETECTORS 3-8 Supply and Branch Line 4-46—4-47 Identification PULLEY ELBOWS 3-8 1.5 Gallon System 4-48 PULLEY TEE 3-9 3.0 Gallon System 4.49 STAINLESS STEEL CABLE 3-9 6.0 Gallon Manifolded System 4-50—4-51 9.0 Gallon System 4-52 TABLE OF CONTENTS UL EX.3470 ULC CEx747 Page 2 REV.7 4-1-06 SECTION PAGES SECTION PAGES IV. SYSTEM DESIGN (Continued) VII. RECHARGE AND RESETTING 7.1 -7-4 DETECTION SYSTEM 4-53-4-54 PROCEDURES REQUIREMENTS CLEANUP PROCEDURES 7-1 Detector Identification 4-53 Detector/Pulley Elbow Quantity 4-53 RECHARGE 7-1 -7-3 Detector Placement Requirements 4-53-4-54 RESETTING 7-3-7-4 Detection Line Requirements 4-54 REPLACEMENT CARTRIDGE 7-4 Fusible Link Selection 4-54 MANUAL PULL STATION 4-55 VIII.MAINTENANCE EXAMINATION 8-1 -8-8 REQUIREMENTS SEMI-ANNUAL MAINTENANCE 8-1 -8-3 MECHANICAL GAS VALVE 4-55-4-56 EXAMINATION REQUIREMENTS 12-YEAR MAINTENANCE 8-4-8-8 ELECTRICAL GAS VALVE 4-56 EXAMINATION REQUIREMENTS Approvals 4-56 IX. APPENDIX 9-1 -9-12 ALARM INITIATING SWITCH 4-56 SYSTEM SELECTION GUIDE 9-1 -9-4 REQUIREMENTS SYSTEM COMPONENT INDEX 9-5-9-6.2 ELECTRICAL SWITCH 4-56-4-59 PARTS LISTS 9-7-9-10.2 REQUIREMENTS MULTIPLE NOZZLE FRYER 9-11 V. INSTALLATION INSTRUCTIONS 5-1 -5-26 PROTECTION CALCULATION MOUNTING THE COMPONENTS 5-1 -5-2.1 EXAMPLES INSTALLING THE ACTUATION 5-3-5-6 AND EXPELLANT GAS LINES INSTALLING THE DISTRIBUTION 5-7 PIPING INSTALLING THE DETECTION 5-8-5-17 SYSTEM Installing"Clip-on"Style Linkage 5-8-5-12 "Scissors"Style Linkage Installation 5-12-5-15 Installing"Hinged"Style Linkage 5-15-5-17 INSTALLING REMOTE MANUAL 5-18-5-19 PULL STATION INSTALLING MECHANICAL 5-19-5-22 GAS VALVE INSTALLING ELECTRICAL 5-23 GAS VALVE INSTALLING ELECTRICAL 5-24 SWITCHES INSTALLING ALARM 5-25 INITIATING SWITCH WIRING 24 VDC REGULATED 5-26 RELEASE ASSEMBLY VI.TESTING AND PLACING IN SERVICE 6-1 -6-4 TESTING MANUAL PULL STATION 6-1 TESTING MECHANICAL GAS 6-1 VALVES TESTING ELECTRICAL GAS 6-2 VALVES TESTING ELECTRIC SWITCH 6-2 TESTING DETECTION SYSTEM 6-3 SECTION I — GENERAL INFORNIATIOtd UL EX.3470 ULC CEx747 Page 1-1 4-1-06 REV.4 - DESIGN AND APPLICATION DEFINITION OFTERMS The ANSUL R-102 Restaurant Fire Suppression System is Actuation Gas Line: Piping from the ANSUL AUTONIAN designed to provide fire protection for restaurant cooking appli- Regulated Release Assembly which supplies nitrogen or carbon antes, hoods,and ducts.It is a pre-engineered group of mechan- dioxide to the Regulated Actuator Assembly for multiple-tank sys- ical and electrical components for installation by an authorized tem actuation. ANSUL distributor. The basic system consists of an ANSUL Agent Tank:A pressure vessel containing the liquid agent. AUTOMAN regulated release assembly which includes a regulat- ed release mechanism and a liquid agent storage tank housed ANSUL AUTOMAN Regulated Release Assembly (Electrical). within a single enclosure. Nozzles, detectors, cartridges, liquid An assembly which contains the regulated release mechanism, agent,fusible links, pulley tees, and pulley elbows are supplied in agent tank(ordered separately),expellant gas hose,solenoid,and separate packages in the quantities needed for each fire suppres- electric switch within a metal enclosure.The enclosure contains sion system arrangement. knockouts to facilitate component hookups. The system provides automatic actuation; or it can be actuated ANSUL AUTOMAN Regulated Release Assembly (Mechani- manually through a remote manual pull station.The system is also cal): An assembly which contains the regulated release mecha- capable of shutting down appliances at system actuation. For nism, agent tank (ordered separately), and expellant gas hose appliance shutdown requirements, refer to the current version of within a metal enclosure. The enclosure contains knockouts to NFPA 17A, "Standard For Wet Chemical Extinguishing Systems," facilitate component hookups. and NFPA 96, "Standard For Ventilation Control and Fire Authority Having Jurisdiction:The"authority having jurisdiction" Protection of Commercial Cooking Operations" is the organization,office,or individual responsible for"approving" Additional equipment includes: remote manual pull station, equipment, an installation, or a procedure.The phrase "Authority mechanical and electrical gas valves,pressure switches,and elec- Having Jurisdiction"is used in a broad manner since jurisdictions trical switches for automatic equipment and gas line shut-off. and "approval"agencies vary as do their responsibilities.Where Accessories can be added,such as alarms,warning lights,etc.,to public safety is primary, the"authority having jurisdiction"may be Installations where required. a federal, state, local, or other regional department or individual The R-102 system suppresses fire by spraying the plenum area, such as a fire chief,fire marshal,chief of a fire prevention bureau, labor department, health department, building official, electrical the filters, cooking surfaces, and the exhaust duct system with a inspector, or others having statutory authority.For insurance pur- predetermined flow rate of ANSULEX Low pH Liquid Fire r Suppressant.When the liquid agent is discharged onto a cooking Poses, an insurance company representative may the"author- appliance fire,it cools the grease surface, and reacts with the hot o having jurisdiction'In many circumstances the property owner or his designated agent assumes the role of the"authority having grease (saponification) forming a layer of soap-like foam on the jurisdiction;"at government installations, the commanding officer surface of the fat.This layer acts as insulation between the hot or departmental official may be the"authority having jurisdiction." grease and the atmosphere,thus helping to prevent the escape of combustible vapors. Blow-Off Cap:A cap which covers the end of the nozzle tip and Exhaust fans in the ventilating system should be left on.The forced prevents grease from plugging the nozzle orifice. draft of these fans assists the movement of the liquid agent Branch Line.The agent distribution piping which extends from the through the ventilating system, thus aiding in the fire suppression supply line to the nozzle(s). process.These fans also provide a cooling effect in the plenum Bursting Disc: A disc installed in the tank adaptor which elimi- and duct after the fire suppression system has been discharged. nates the siphoning of the agent up the pipe during extreme tem- The system Is UL listed with or without fan operation, perature variations. ►Make up or supply air fans, integral to the exhaust hood(s) being Cartridge:A seated, steel pressure vessel containing nitrogen or .protected,shall be shut down upon system actuation. carbon dioxide gas used to pressurize the agent tank. Along with the fire suppression system, the total system design Cooking Appliance: Includes fryers, griddles, ranges, upright must Include hand portable fire extinguisher(s) located within the broilers, chain broilers, natural charcoal broilers, or char-broilers cooking/restaurant area that can be used to manually suppress a (electric, lava rock,gas-radiant,or mesquite). fire that may be burning in an unprotected area.Refer to NFPA 10, "Standard For Portable Fire Extinguisher," for additional Cooking Area: Cooking area is defined as the maximum surface information. that requires protection. Each type of appliance has a defined cooking area.For example,the maximum cooking area is the fry- UL LISTING pot for a fryer without a dripboard and the maximum cooking area The R-102 Restaurant Fire Suppression System has been tested is the combined frypot and dripboard for a fryer with a dripboard. and is listed by Underwriters Laboratories, Inc. as a pre-engi- Conduit Offset Assembly:A pre-formed piece of conduit which neered system. The system is in compliance with UL Test can be installed between the ANSUL regulated release and the Standard 300.These tests require extinguishment of fires which conduit to allow the wire rope for the detection, gas valve and are initiated in deep fat fryers, ranges, griddles, char-broilers, remote manual pull station to be installed in a more convenient woks, upright broilers, chain-broilers, filters, plenum chambers, manner. hoods, and ducts after pre-loading each appliance with a pre- Depth: When referring to depth as a linear dimension, it is the scribed amount of cooking grease.Each fire is allowed to progress horizontal dimension measured from front to back of the appliance to maximum intensity before the fire suppression system is or plenum. actuated. SECTION I — GENERAL INFORMATION UL EX.3470 ULC CEx747 Page 1-2 REV.5 4-1-06 DEFINITION OFTERMS(Continued) Pre-engineered System: NFPA 17A defines a pre-engineered Detector:A device which includes the detector bracket, detector system as one which has "...predetermined flow rates, nozzle linkage, and fusible link used for automatic operation of the fire pressures, and quantities of liquid agent."The R-102 system, as suppression system. prescribed by UL(Underwriter's Laboratories), has specific pipe sizes, maximum and minimum pipe lengths and numbers of fit- Detector Linkage:A device used to support the fusible link. tings,and number and types of nozzles.The hazards protected by Distribution Piping:Piping which delivers the extinguishing agent this system are also specifically limited as to type and size by UL from the tank to each discharge nozzle.See also Supply or Branch based upon actual(ire tests.All limitations on hazards that can be lines. protected and piping and nozzle configurations are contained in Ducts(or Duct System):A continuous passageway for the trans- the R-102 installation and maintenance manual which is part of mission of air and vapors which, in addition to the containment the UL listing. components themselves, may include duct fittings, plenums, Pulley Elbow:A device used to change the direction of the wire and/or other items or air handling equipment. rope which runs between:the regulated release mechanism and Electrostatic Precipitator:A device used to aid in the cleaning of the detectors, the regulated release mechanism and the mechan- the exhaust air. This device is normally installed at or near the ical gas valve, and/or the regulated release mechanism and the base of the ventilation duct. remote manual pull station. Expellant Gas Line:Piping and/or hose which supplies the nitro- Pulley Tee: A device used to change the direction of two wire gen or carbon dioxide gas from the regulated release assembly/ ropes which run from a regulated release or a regulated actuator regulated actuator assembly to each agent tank. to two remote manual pull stations,or from two regulated releases Flow Number:Term used in system design to describe the flaw or regulated actuators to a single mechanical gas valve or from one regulated release or regulated actuator to two gas valves. capacity of each nozzle used to determine the quantity of tanks needed to cover a certain group of hazards. Regulated Actuator Assembly:An assembly which contains the Fusible Links:A form of fixed temperature heat detecting device regulator,pneumatic actuator,agent tank,and expellant gas hose within a metal enclosure.This assembly is used to pressurize addi- employed to restrain the operation of a mechanical control until its tional agent tanks in a multiple tank system. designed temperature is reached. Gas Valve:A device used to shut off the gas supply to the cook Regulated Release Mechanism:An enclosed device within the ANSUL AUTOMAN regulated release assembly which releases ing equipment when the system is actuated. the expellant gas, activates alarms, and/or shuts off other devices Gas Valve Air Cylinder: An air cylinder, located in the release when signaled automatically by a detector or manually with a mechanism, which operates pneumatically to mechanically remote pull station. unlatch a mechanical gas valve actuator,causing the gas valve to Regulator:A device used to regulate the pressure from the nitro- close upon system actuation. gen cartridge into the agent tank(s)when the system is actuated. High Proximity:Indicates a distance(vertically)between the noz- Remote Manual Pull Station: A device which provides manual zle tip and the surface of the appliance being protected. actuation of the system from a remote location. tune grease-ladenprovided s for cooking and exhaust gasesces lt shall direct cons and apt- Salamander Broiler:A broiler very similar in design to the upright ed in a manner which meets the requirements of NFPA 96. broiler.A salamander broiler is used for general broiling of meats and fish, toasting, and holding/warming foods. Most contain a Liquid Agent. A potassium-based solution used for the knock- removable grease drip tray. down and suppression of fire. 1 Silicone Lubricant: A heat-resistant organic compound used to Low Proximity:Indicates a distance(vertically) between the noz- ► lubricate O-rings, rubber and mechanical components. zle tip and the surface of the appliance being protected. Supply Line:The agent distribution piping which extends from the Maximum Length of Cooking Appliance:The maximum dimen- agent tank outlet and serves as a manifold for the branch lines. sion,on any side,which may be protected by one nozzle. Series Detector: Any detector located in-line between the regu- Maximum Piping: Specified length of piping and number of fit- lated release assembly and the terminal detector. tings which must not be exceeded for each system. Terminal Detector:The last in a series of detectors, or the only Medium Proximity: Indicates a distance (vertically) between the detector used in a single-detector system. This detector is thus nozzle tip and the surface of the appliance being protected. named because it is at the point at which the wire rope ends, Minimum Piping: Minimum length of distribution piping required or"terminates."There is only one terminal detector per detection between the agent tank outlet and any nozzle protecting a griddle, system, range,or fryer. Transition:An extension of the hood or canopy which allows for Nozzle:A device designed to deliver the liquid agent with a spe- the smooth transmission of gases, air, and vapors between the cific flow rate and stream pattern. hood opening and the base of the ventilation duct. Overlapping Protection: When discharge nozzles are spaced Vent Plug:A device used to prevent pressure build-up within the equally apart over one or more appliances requiring protection. agent tank or agent distribution lines due to temperature Nozzles used in this manner provide area protection of eligible fluctuations. appliances within the protected area.Two types of overlapping pro- tection is available:full hood continuous protection and group pro- tection.Overlapping protection is in addition to appliance specific coverages. Plenum:The space enclosed by the filters and the portion of the hood above the filters. SECTION II—SYSTEM DESCRIPTION UL EX.3470 ULC CEx747 Page 2-1 3-1-04 REV.3 TOTAL SYSTEM There are three types of R-102 Restaurant Fire Suppression Double-Tank System Systems: The R-102 double-tank system is available with a stainless steel 1.Single-tank System enclosure and consists of: 2.Double-tank System 1. ANSUL AUTOMAN Regulated Release Assembly (Electrical 3.Multiple-tank System or Mechanical) The type of system required for the particular installation will be 2• Nitrogen Cartridge andfor Carbon Dioxide Cartridge determined through the guidelines covered in "System Design." 3. ANSULEX Low pH Liquid Fire Suppressant Additional equipment which may be required to complete the sys- 4. Enclosure or Bracket Assembly tem design is explained in the "System Components" section. Additional devices covered are: remote manual pull stations, 5. Discharge Nozzles mechanical and electrical gas shut-off valves, electrical switches, 6. Detection Components and pressure switches. 7. Additional Devices(As Required) Single-Tank System The regulated release assembly contains the regulated release The R-102 single-tank system is available with a stainless steel ►mechanism,agent tank,expellant gas hose for agent tank hookup, enclosure and consists of: and enclosure knockouts to facilitate installing expellant piping, 1.ANSUL AUTOMAN Regulated Release Assembly (Electrical detection system,and additional equipment. or Mechanical) The enclosure or bracket assembly is mounted separately but within the guidelines of the regulated release assembly expellant 2.Nitrogen Cartridge and/or Carbon Dioxide Cartridge gas piping requirements to ensure simultaneous actuation of the 3.ANSULEX Low pH Liquid Fire Suppressant system.Refer to"System Components'section for individual com- 4.Discharge Nozzles ponent descriptions. 5.Detection Components 6.Additional Devices(As Required) The regulated release assembly contains the regulated release ►mechanism,agent tank,expellant gas hose for agent tank hookup, and enclosure knockouts to facilitate installing detection system and additional equipment.Refer to"System Components"section for Individual component descriptions. �a a O(Z)O t� a a ®r,,� FIGURE 2 aoo i a+ FIGURE 1 SECTION If—SYSTEM DESCRIPTION UL EX.3470 ULC CEx747 Page 2-2 REV.4 3-1-04 TOTAL SYSTEM(Continued) Multiple-Tank System The R-102 multiple-tank system is available with a stainless steel enclosure and consists of: 1.ANSUL AUTOMAN Regulated Release Assembly (Electrical or Mechanical) 2.Nitrogen Cartridge(s)and/or Carbon Dioxide Cartridge(s) 3.Regulated Actuator Assembly(ies) 4.ANSULEX Low pH Liquid Fire Suppressant 5.Enclosure or Bracket Assembly(ies) 6.Discharge Nozzles 7.Detection Components 8.Additional Devices(As Required) The regulated release assembly contains the regulated release ►mechanism,agent tank,expellant gas hose for agent tank hookup, and enclosure knockouts to facilitate installing actuation piping, expellant piping,detection system, and additional equipment. Each regulated actuator assembly is mounted separately but with- in the guidelines of the regulated release assembly actuation/ expellant gas piping'requirements to ensure simultaneous actua- tion of the system.The assembly contains the pneumatic actuator, ►regulator, agent tank, expellant gas hose for agent tank hookup, and enclosure plugs to facilitate installing expellant piping. Each enclosure or bracket assembly is mounted separately but within the guidelines of the regulated release assembly or regulat- ed actuator assembly expellant gas piping requirements to ensure simultaneous actuation of the system. Refer to "System Components"section for individual component descriptions. 0 0 0 0 FIGURE 3 ao,3 SECTION III—SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-1 4-1-06 REV.5 EXTINGUISHING AGENT ANSULEX Low pH Liquid Fire Suppressant(1.5 gallon—Part NO. "ANSUL AUTOMAN"REGULATED RELEASE ASSEMBLY 79694 or 3.0 gallon—Part No.79372)is a potassium-based solu- (MECHANICAL) tion designed for fast knock-down and suppression of grease- related fires.The agent is shipped in plastic containers which pro- NOTE:AGENT TANK MUST BE vide one complete tank charge.(Refer to Section V,Page 5-2.1,for ORDERED SEPARATELY C OR SEE PAGE 3-4 ►maximum agent fill capacity.) Agent storage life expectancy is d o twelve years.The distributor must record the batch numbers and RELEASE date of shipment receipt to be filed with each installation record. MECHANISM 'ANSULEV LOW pH LIQUID FIRE SUPPRESSANT e `4 I I 0 REGULATOR i 3.0 GALLON 1.5 GALLON SHIPPING W..25 LB.(11 kg) SHIPPING WT.35 LB.(I6 kg) SHIPPING'WT.19 LB.(9 kg) OpOt3d Ofp137 FIGURE 1 FIGURE 2 aoouu REGULATED RELEASE ASSEMBLY(MECHANICAL) REGULATED RELEASE ASSEMBLY(ELECTRICAL) The ANSUL AUTOMAN Regulated Mechanical Release Assembly The ANSUL AUTOMAN Regulated Electrical Release Assembly (Part No. 429853) contains the regulated release mechanism, (Part No.429856) is identical to the mechanical version except it expellant gas hose for agent tank hookup, and enclosure knock- also contains a factory installed 120 VAC solenoid and electrical outs to facilitate installing actuation piping;expellant piping;detec- switch. tion system; and additional equipment. This regulated release The solenoid is used to provide electrical actuation of the release assembly is used in single,double,and multiple-tank systems and mechanism.The electric switch is used to protect the solenoid by must be mounted to a rigid surface.The release mechanism can opening the circuit to the solenoid once the system is fired. be used to interconnect both the actuation and expellant gas lines Additional electrical switches can be added as required for auto- as required per system design.The regulator is designed to allow matic equipment and gas shut-off accessories,as well as initiating a constant flow of gas into the tank at 110 psi(759 kPa)when the audible and visual alarms. system is actuated.The agent tank must be ordered separately. In single, double, and multiple-tank systems, the provided expel- "ANSUL AUTOMAN"REGULATED RELEASE ASSEMBLY lant gas hose connects the agent tank to the bottom outlet of the ► (ELECTRICAL)" regulator. In double and multiple-tank system configurations, the back outlet of the regulator is used as an expellant gas feed for NOTE:AGENT TANK MUST BE ORDERED a$ o one additional tank-enclosure or tank-bracket hookup.The enclo- SEPARATELY sure contains the required knockouts to facilitate this connection. OR SEE PAGE 3-4 If a pressure switch is to be attached to the regulator,additional fit- tings are required. REGULATOR swlrcH The tank Is mounted within the enclosure.The tank contains an adaptodtube assembly with a burst disc union. The burst disc helps prevent siphoning of the agent up the pipe due to significant temperature fluctuations in the area where the tank is located.The I SOLENOID tank is mild steel and,under normal conditions,requires hydrosta- tic testing every twelve years. ` The detection and additional equipment required per system design are connected to the release mechanism.The enclosure contains knockouts to facilitate detection and additional hookups. The system can be actuated automatically or manually.Automatic actuation occurs when a fusible link within the detection system SHIPPING WT.3.1 LB (15 kg) separates in a fire condition. Manual actuation of the system occurs when personnel pull on the remote manual pull station pull ring. FIGURE 3 000139 ►'NOTE:ANSUL AUTOMAN Regulated Electrical Release,Part No.429856,is not ► intended to be used with electric detection. SECTION III—SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-2 REV.5 4-1.06 ►REMOTE MECHANICAL RELEASE The tank bracket is constructed of mild steel and painted red.It is The Remote Mechanical Release, Part No. 433485, is used to designed for mounting the tank in a minimum amount of space, actuate up to five (5) R-102 regulated actuators. The remote The Bracket Assembly can only be utilized with 3.0 gallon tanks mechanical release utilizes a 101-10 carbon dioxide cartridge as (Part No.429862). the actuation pressure to operate the regulated actuators. The BRACKET ASSEMBLY release is housed in a stainless steel enclosure. MOUNTING m 0 BRACKET 0 RELEASE (I MECHANISM , o I I I I I I I I I O O I ( r I I I I I SHIPPING WEIGHT: I e 20 LB.(9.1 kg) I e FIGURE 4 SHIPPING WT.7 I.S.(3 kg) FIGURE 6 WOW SINGLE TANK ENCLOSURE ASSEMBLY The Single Tank Enclosure Assembly(Part No.429870)is used in REGULATED ACTUATOR ASSEMBLY double and multiple-tank systems and must be mounted to a rigid The Regulated Actuator Assembly (Part No. 429850) contains the surface near the regulated release Or regulated actuator assembly regulator, pneumatic actuator, expellant gas hose for agent tank its expellent gas line will be connected to. hookup,and enclosure knockouts to facilitate Installing expellant pip- The enclosure is designed for mounting either a 1.5 gallon (Part ing. This assembly is used in multiple-tank systems and must be No.429864)or a 3.0 gallon tank(Part No.429862) in a minimum mounted to a rigid surface. amount of space. The regulator contains two outlets 135' apart.One outlet is used to interconnect the expellant gas hose to the enclosed agent tank. ENCLOSURE ASSEMBLY The other outlet connects an expellant gas line to an additional ► enclosure or bracket assembly.The regulator is designed to allow NOTE:AGENT TANK MUST ° ° m a constant flow of nitrogen into each agent tank connected (two BE ORDERED 0 tanks maximum)at 110 psi(759 kPa). SEPARATELY 0 The pneumatic actuator is designed to puncture the expellant as OR SEE PAGE 3-t P 9 P P 9 cartridge seal upon receiving pressure from the regulated release assembly actuation piping.The enclosure contains a knockout to 0 facilitate distribution piping hookup. 0 REGULATED ACTUATOR ASSEMBLY MOUNTING -� ENCLOSURE NOTE:AGENT TANK m MUST BE 15 ORDERED PNEUMATIC SEPARATELY ACTUATOR S SHIPPING WT. OR SEE PAGE 3.4 ASSEMBLY 13 I.S.16 kg) o � C REGULATOR I ► FIGURE 5 00014. RED PAINTED BRACKET ASSEMBLY SHIPPING arr. The Bracket Assembly (Part No. 429678) is used in double and 19 LB.(9 kg) multiple-tank systems and must be mounted to a rigid surface near the regulated release assembly or regulated actuator assembly FIGURE 7 that its expellant gas line will be connected to. W0143 SECTION III—SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-3 4-1-06 REV,8 AGENT TANK ASSEMBLY OEM REGULATED ACTUATOR ASSEMBLY The agent tank shipping assembly (3-Gallon, Part No. 429862, The OEM Regulated Actuator Assembly, Part No. 418691, and 1.5 Gallon, Part No.429864)consists of a stainless steel tank includes the regulator,pneumatic actuator,expellant gas hose and and an adaptor/tube assembly.The adaptor/tube assembly con- OEM bracket. Also available is an OEM Regulated Actuator tains a burst disc.The burst disc prevents agent leakage due to Assembly with all the above mentioned components except for the significant temperature fluctuations in the area where the tank is bracket.This assembly is Part No.418522. located. Under normal conditions, the tank requires hydrostatic testing every twelve years.The date of manufacture is stamped on the tank nameplate. The tank is shipped uncharged and must be filled with only ANSULEX Low pH Liquid Fire Suppressant during installation. s TANK ADAPTOR/ TUBE ASSENIBUl' 9 3 GALLON SHIPPING'NT. 7 LB.(3 kg) 1.5 GALLON SHIPPING WT 5 LB.(2 kg) AGENT T.SHIPPING W 4 LB.(2 kg) ► TANK FIGURE 10 oo� TWO TANK ENCLOSURE ASSEMBLY ► FIGURE 8 The Two Tank Enclosure Assembly, Part No.429872, consists of 77i0 two expellant gas hoses, two grommets,and the mounting enclo- sure.The assembly is used in 9 gallon systems.It can be coupled OEM RELEASE/BRACKET ASSEMBLY with a 3-gallon regulated release assembly or a 3-gallon regulated (FOR OEM IN-CABINET USE ONLY) actuator assembly to give a total of 9 gallons of agent.Agent tanks The OEM Regulated Mechanical Release/Bracket Assembly, Part must be ordered separately. No. 79493, contains the same regulated release mechanism as The tank enclosure is designed to mount in a minimum amount of the standard ANSUL AUTOMAN Regulated Release Assembly. space. The OEM Regulated Electrical Release/Bracket Assembly, Part ►No.418054%is Identical to the mechanical version except it con- tains a factory installed 120 VAC solenoid and electrical switch, a� These release/bracket assemblies must be installed in a suitable equipment enclosure either horizontally or vertically.They co&ain all the necessary mounting and conduit holes needed to fully install the assembly. The agent tank is installed separately and SHIPPING WT. need not be bracketed once it is piped and filled. Note:OEM 26 LBS.(12 kg) Release/Bracket Assembly must be installed high enough In cabi- net so that there is sufficient room to install and remove cartridge. ►'Note:OEM Regulated Electrical Release/Bracket Assembly,Part No.418054,is ► not intended to be used with electric detection. en.? cn o FIGURE 11 aoun RELEASE MOUNTING MECHANISM-► 0 BRACKET i a 0 REGULATOR � SHIPPING WT. ° 10 I.B.(5 kg) FIGURE 9 Owl" SECTION III -SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-4 REV.7 4-1-06 24 VDC REGULATED RELEASE ASSEMBLY(ULC APPROVED ADDITIONAL SHIPPING ASSEMBLIES ONLY) Several complete shipping assemblies are available containing The 24 VDC Regulated Release Assembly, Part No. 429859, is both the release or actuator mechanism and the agent tank.When used where electric,thermostat detection is required via the use of ordering a complete shipping assembly, order the following part a releasing control unit. This assembly consists of a 24 VDC numbers: ANSUL AUTOMAN II-C regulated release mechanism, expellant gas hose,and enclosure knockouts to facilitate installing actuation Shipping Wt. piping, expellant piping, detection system, and additional equip- Part No. Description lb. (kg) ment.Agent tank must be ordered separately. 430299 3.0 Gallon Mechanical Release 33 (15) The system can be actuated automatically or manually.Automatic Shipping Assembly including: actuation occurs when the control panel receives a signal from the 429853 Mechanical Regulated detection circuit.The panel then sends an electrical signal to the Release Assembly 24 VDC regulated release, causing it to actuate.When actuation 429862 3.0 Gallon Tank Assembly occurs,the gas cartridge is punctured,pressurizing the agent tank 430300 1.5 Gallon Mechanical Release 30 (14) and discharging the agent through the distribution piping.Manual Shipping Assembly Including: actuation of the system occurs when personnel pull on the remote 429853 Mechanical Regulated manual pull station pull ring. Release Assembly 429864 1.5 Gallon Tank Assembly O NOTE:AGENT EREDS SEPMUSARATELY 430309 3.0 Gallon Regulated Actuator 36 (16) BE ORDERED SEPARATELY g Shipping Assembly including: SHIPPING WT. 429850 Regulated Actuator Assembly 3.9 LS.(IS kg) 429862 3.0 Gallon Tank Assembly 430316 1.5 Gallon Stainless Steel Enclosure 18 (8) Shipping Assembly including: - 429870 Single Tank Mounting Box O Assembly 429864 1.5 Gallon Tank Assembly 418511 Hose Assembly 430317 3.0 Gallon Stainless Steel Enclosure 20 (9) ` FIGURE 12 Shipping Assembly including: 429870 Single Tank Mounting Box Assembly 429862 3.0 Gallon Tank Assembly 418511 Hose Assembly 430324 6.0 Gallon Stainless Steel Enclosure 40 (18) Shipping Assembly Including: 429872 Two Tank Mounting Box Assembly 429862 3.0 Gallon Tank Assembly(2) 430332 3.0 Gallon Mounting Bracket Shipping 20 (9) Assembly including: 429878 3.0 Gallon Mounting Bracket Assembly 429862 3.0 Gallon Tank Assembly I SECTION III—SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-5 4-1.06 REV.6 GAS CARTRIDGES NOZZLES The R-102 system uses gas cartridges to store nitrogen or carbon ►There are 11 types of discharge nozzles each designed to distrib- dioxide expellant gases under pressure until the system is actuat- ute the liquid agent.in a uniform pattern throughout the hazard ed, at which time the cartridge seal Is punctured and the released area: gas expels liquid agent from one or more tanks through the dis- 1. 1 W Nozzle 7. 245 Nozzle charge piping and out the discharge nozzles. 2, IN Nozzle 8. 260 Nozzle Four nitrogen gas cartridges and three carbon dioxide gas car- 3. 1/2N Nozzle 9. 290 Nozzle ►tridges are available as shown in Figure 13. 4. 3N Nozzle 10. 2120 Nozzle Cartridges noted as TC/DOT are both Transport Canada(TC)and 5. 2W Nozzle 11. 1 F Nozzle Department of Transportation (DOT) approved. Cartridges noted . 6. 230 Nozzle as DOT are Department of Transportation approved only. Cartridge selection options are provided in Section IV under Tank Although these nozzles are similar in appearance and have and Cartridge Requirements. certain common parts, the tip of each nozzle is designed for a specific application and must only be used in those areas. See NITROGEN GAS CARTRIDGES Nozzle Application Chart in Section IV — System Design, for individual nozzle usage. WS—16 NPT 7 718 IN. FEMMALE THREAD (20 cm) 113191N10 I/2 ifI (2A.9 cm) (27 cm 14 see IN. (37.1 cm) 2 I2 IN. INTERNAL CUP (6.4 cm) STRAINER 2 1r2 IN. 4 3/16 IN. INSIDE (6.4 cm) (10.6 cm) RECESS FOR ► 3 9/16 IN. BLOW OFF (9 cm) CAP LOOP XXXX-X VENDOR CODE LT-20-R LT-30-R DOUBLE-TANK LTA-101-30 NOZZLE (IF PRESENT) CARTRIDGE CARTRIDGE CARTRIDGE CARTRIDGE STAMPING PART NO.423429 PART NO.423,135 PART NO.423.193 PART NO.423491 -- - (TC/DOT) (TC/DOT) (TCADOT) (TC00T) ooau aoaiJe acon- coo IJ3 ► FIGURE 14 mcca2 CARBON DIOXIDE CARTRIDGES Nozzle Identification Chart Nozzle Nozzle Nozzle Nozzle' Flow 9 IN, 7 7/8 IN. Tvoe Part No, in No. Nozzle Identifiotion (22.9 cm) (20 cm) 1 1 5/8 IN. 1 W Nozzle 419336 1 W 1 Chrome-Plated Body — (29.5 cm) IN Nozzle 419335 IN 1 Chrome-Plated Body 1/2N Nozzle 419334 1/2N 1/2 Chrome-Plated Body Metal blow-off caps are not allowed with the 1/2N nozzle (S.I cm) (6.4 cmj 1 3N Nozzle 419338 3N 3 Chrome-Plated Body 212IN. 2W Nozzle 419337 2W 2 Chrome-Plated Body (6.4 cm) 230 Nozzle 419339 230 2 Chrome-Plated Body PART NO CARTRIDGE10 43 TCOT) (PART NO.423441E (PART NO.4234 3E 245 Nozzle 419340 245 2 Chrome-Plated Body PART NO.15850(DOT) (TCIDOT) (TCIDOT) 260 Nozzle 419341 260 2 Chrome-Plated Body Op/IJ7 W0150 CC0161 FIGURE 13 290 Nozzle' 419342 290 2 Chrome-Plated Body 2120 Nozzle 419343 2120 2 Chrome-Plated Body ► 1 F Nozzle 419333 IF 1 Chrome-Plated Body Nozzle stamping may contain an additional letter Indicating a vendor's code.- SILICONE LUBRICANT IDow Corning Compound 111, Part No. 78112, is available in a 5.3-ounce tube.Compound has excellent qualities for sealing and .lubricating system components. SECTION III—SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-6 REV.5 4-1-06 SWIVEL ADAPTOR >CB METAL BLOW-OFF CAP FOR CHAIN BROILERS The Swivel Adaptor Assembly, Part No.418569,consists of a swiv- The CS Metal Blow-off Cap, Part No.433208, is used for all chain el nut,swivel body and swivel ball.All are chrome-plated.The SNiv- broilers protected overhead with the 2W nozzle in high tempera- el adaptor allows any nozzle to be rotated approximately 301 in all ture environments. The metal blow-off cap contains a special directions.Swivel Adaptors must be ordered as a Swivel Adaptor O-ring placed inside the cap which integrates with the 2W nozzle Shipping Assembly, Part No. 423572, which contains 25 Swivel to create a seal and to help hold the blow-off cap in position. Adaptors. The CS Metal Blow-off Cap Assembly, Part No.433208, contains 10 blow-off caps. P 318-I8NPTFEMALE THREADCONDUIT OFFSET ASSEMBLY The conduit offset assembly, Part No. 79825, is used to change direction of the wire rope on detection,mechanical gas valve,and remote pull station lines.The conduit offset assembly can only be 3'8used in the area where the conduit attaches to the regulated ' a MALEPT T READ release assembly. When using the conduit offset assembly, the 30 DEGREE maximum number of pulley elbows is still allowed. The Conduit ROTATION Offset Shipping Assembly, Part No. 79825, consists of 6 conduit ' FIGURE 15 offsets. OCO"43 r CONDUIT RUBBER BLOW-OFF CAPS COUPLING The Rubber Blow-Off Cap, Part No.77676,help keep the orifice of the nozzle free of grease or other substances that could Interfere with agent distribution.A retaining strap attaches the blow-off cap CONDUIT to the nozzle. Rubber Blow-Off Caps must be ordered as a I OFFSET Shipping Assembly, Part No. 77695, which contains 50 blow-off caps, or Part No.77411, which contains 12 blow-off caps. CONDUIT CONNECTOR \l� FIGURE 18 000153 "QUIK-SEAL"ADAPTOR ' FIGURE 16 The"Quik-Seal"adaptor is a listed mechanical bulkhead fitting that produces a liquid-tight seal around both distribution piping and detection conduit which runs through restaurant hoods and ducts. METAL BLOW-OFF CAP The "Quik-Seal" adaptor accepts threaded pipe or conduit. The Two types of metal blow-off caps are available as options to the adaptor is available for 1/4 in. (Part No.78195), 3/8 in. (Part No. standard rubber caps. The metal cap can be used in unusually 77284), 1/2 in.(Part No.77286),or 3/4 in.(Part No.77288)pipe or high heat conditions, generally over 400 OF (204 °C).The metal conduit sizes.When using with EMT conduit, a conduit connector blow-off cap is attached to the nozzle by means of a stainless steel must be installed in each end of the adaptor. The "Quik-Seal" wire which prevents it from falling into the appliance during dis- Adaptor Shipping Assembly must be ordered as stated below: charge. Shipping Assembly Part No. 79745 contains 10 metal Shipping blow-off caps for use on standard, non-swivel nozzles and Assembly Hole Size Shipping Assembly Part No. 415568 contains 10 metal blow-off Size Part No. Qty. Required caps for use on swivel nozzles. 1/4 in. 78196 24 3/4 in. NOTICE 3/8 in. 77285 24 1 1/6 in. If metal blow-off caps are required for upright broil- 1/2 in, 77287 24 1 1/8 in. er or salamander protection, use (2) two IN noz- 3/4 in. 77289 24 1 3/8 in. zles(Part No.419335)instead of 112N nozzles. COMPRESSION NUT J STAINLESS ADAPTOR BODY - STEEL WIRE GASKET LOCKWASHER NUT-a FIGURE 19 METAL CAP FIGURE 17 OCQt 52 SECTION III—SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-7 4-1-06 REV.5 "COMPRESSION-SEAL"ADAPTOR This adaptor is a mechanical bulkhead fitting that produces a liquid-tight seal around pipe and conduit when installing distribu- tion piping and detection conduit through restaurant hoods and ducts. The "Compression-Seal" adaptor is a straight-through design requiring no cutting or threading of conduit or pipe.The adaptor is available for pipe sizes of 1/4 in. (Part No.79148), 3/8 in.(Part No.79150), 1/2 in.(Part No.79146),and EMT conduit size of 1/2 in. (Part No. 79152). Each "Compression-Seal" Adaptor Shipping Assembly must be ordered as stated below: Shipping Assembly Hole Size Size Part No. Qty. Required 1/4 in.Pipe/112 in.tube 79149 24 3/4 in. 3/8 in.Pipe/5/8 in.tube 79151 24 1 1/8 in. 1/2 in.Pipe 79147 24 1 1/8 in. 1/2 in.EMT Conduit 79153 24 1 1/8 in. a-ADAPTOR BODY GASKET LOOKWASHER JUT FIGURE 20 wotu "HOOD SEAL"ADAPTOR ASSEMBLY I This adaptor is a mechanical bulkhead fitting that produces a liq- uid-tight seal around 1/2 in.EMT conduit when installing the detec- tion line through restaurant hoods and duct.The adaptor accepts a high temperature pulley elbow and, when used, correctly posi- tions the elbow or conduit in line with the conduit adaptor hole in the detector bracket.The"Hood Seal'eliminates the need for mul- tiple elbows when penetrating the top of a hood when installing the detection line."Hood Seal"Adaptors are available in quantities of 6 as Shipping Assembly Part No.423253. /SEAL NUT SEAL t ER ADAPTOR BODY PULLEY ELBOW (NOT PART OF ASSEMBLY) USE ONLY PULLEY ELBOW, PART NO.423250 FIGURE 21 W0,68 SECTION III—SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-8 REV.7 4.1-06 DETECTORS CLIP-ON STYLE-PART NO-5,3837 AND 56838 The detector consists of three basic components:the bracket,link- age, and fusible link. (Fusible links are not included and must be f ordered separately.)The bracket holds the entire assembly to the FUSIBLE / mounting surface.The linkage is used to support the fusible link.- LINKAGE FUSIBLE BRACKET The fusible link is designed to separate at a specific temperature \ and release the wire rope, thereby actuating the regulated release mechanism. There are three styles of detectors available:the clip-on style, the HINGED STYLE—PART NO.15373 APJD 15375 hinged style,and the scissor style. The clip-on style allows the wire rope to be strung completely IO through the detection system conduit and brackets first and the detector linkage assemblies are then clipped on later. LINKAGE FUSIBLE LINK BRACKET The hinged style detector requires the wire rope to be strung to the detector bracket,and then"threaded"through the linkage assem- bly before continuing to the next detector bracket. The scissor style allows the wire rope to be strung completely ;Sa through the detection system conduit and brackets first and the detector linkage assemblies are then clipped on later. sclssoa STYLE-PART No.4173sa Arlo a173ss Each style of detector consists of two types of assemblies: BRACKET The Terminal Detector (Part No. 56838, 15375, or 417368) LINKAGE includes a test link and is placed last in a series of detectors.This detector is sometimes referred to as the end-of-line detector and is thus named because it is at the point at which the wire rope"ter- FUSIBLE minates,"or is anchored at the detector bracket.Only one terminal LINK detector is required per detection system. The Series Detector(Part No. 56837,15373,or 417369) is any ► "0f'� detector located in-line between the regulated release assembly FIGURE 22 and the terminal detector. PULLEY ELBOWS When using Part No.56837 and 56838 style detectors, a total of There are two types of pulley elbows used to change the direction 12 detectors can be in one detection system:11 series detectors, of the wire rope by 90°.ANSUL recommends for temperatures not Part No.56837 and 1 terminal detector,Part No.56838. In excess of 700 °F (371 °C). Part No.415670 has socket ends When using Part No.15373 and 15375 style detectors, a total of 5 with set screws for 1/2 in.conduit,and Part No.423250 has com- detectors can be in one detection system:4 series detectors,Part pression ring ends also for 1/2 in.conduit.Pulley elbows must be No.15373 and 1 terminal detector, Part No.15375. ordered in quantities of 50 as Shipping Assembly Part No.415671 When using Part No.417368 and 417369 style detectors, a total (socket end type)and Part No.423251 (compression end type). of 15 detectors can be in one detection system: 14 series detec- PART NO.415670 PART NO.423250 tors,Part No.417369 and 1 terminal detector, Part No.417368. ®o 0 coo+n "lei ' FIGURE 23 SECTION III—SYSTEM COMPONENTS UL EX.3470 ULC CEX747 Page 3-9 4-1-06 REV.4 PULLEYTEE MECHANICAL GAS VALVES The Pulley Tea Part No.427929 is used to change the direction The mechanical gas valves are designed to shut off the flow of as of bNo wire ropes by 90 It must be used in areas where the tem- to the appliances upon actuation of the regulated release assem- peratures are within the range of 32°F to 130°F(0°C to 54 °C), Uy.The valves are available in sizes of 314 in., 1 in., 1 1/4 in., 1 1/2 Pulley tees can be used in mechanical gas valve actuation lines in., and 2 in.ANSUL style;and 2 1/2 in.and 3 in.Asco style.The and remote manual pull station lines. Pulley tees cannot be used valves are rated for natural and LP gas.Both styles are UL Listed within a detection line. and includes the air cylinder, tubing, and fittings for connection to the release mechanism. Maximum ® p Part Operating No. Description Pressure 55598 , 3/4 in.Gas Valve (ANSUL) 10 psi (.69 bar) 55601 1 in.Gas Valve(ANSUL) 10 psi(.69 bar) 55604 1 1/4 in.Gas Valve(ANSUL) 10 psi(.69 bar) ' FIGURE 24 55607 1 1/2 in.Gas Valve(ANSUL) 10 psi(.69 bar) 00a"' 55610 2 in.Gas Valve(ANSUL) 10 psi(69 bar) STAINLESS STEEL CABLE 25937 2 1/2 in.Gas Valve(ASCO) 5 psi (.35 bar) The 1/16 in.stainless steel cable is run from the terminal detector, 25938 3 in.Gas Valve(ASCO) 5 psi(.35 bar) through conduit, all series detectors and pulley elbows, and into A B C the regulated release mechanism trip lever.When any fusible link Valve Size in. (mm) in. (mm) in. (mm) separates, the tension on the cable is relaxed, and the trip lever 3/4 in. 3 314 (95.3) 6 3/8 (161.9) 5 1/2 (139.7) actuates the regulated release mechanism.The cable can also be 1 in. 3 3/4 (95.3) 6 3/8 (161.9) 5 1/2 (139.7) used for mechanical gas valves and remote manual pull stations. 1 1/4 in. 4 718 (123.8) 7 3/8 (187.3) 6 3/8 (161.9) The cable is available in 50 ft.(15 m) (Part No.15821) and 500 ft. 1 1/2 in. 4 7/8 (123.8) 7 3/8 (187.3) 6 3/8 (161.9) (152.4 m) (Part No.79653)lengths. 2 in. 5 7/8 (149.2) 7 718 (200.0) 6 11/16 (169.9) 2 1/2 in. 7 13/16 (198.4) ----- 9 1/16 (230.2) REMOTE MANUAL PULL STATION - 3 in. 7 25/32 (197.6) ----- 9 1/16 (230.2) i The remote manual pull station(Part No.4835 or Part No.54011) is required for manual actuation of the regulated release assembly. The remote manual pull station should be mounted at a point of egress and positioned at a.height determined by the authority c having jurisdiction.Trim rings, Part No. 427074 (pack of 10), are available. PART NO.4835(WITHOUT CABLE) j PART NO.54011(`KITH 50 FT OF CABLE) � + A --� 314 IN.THRU 2 IN. 2 M IN,THRU 3 IN. FIGURE 26 METAL STAMPED aoa� ' FIGURE 25 SECTION III—SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-10 REV.3 4-1-06 ELECTRICAL GAS VALVES ELECTRICAL SWITCHES The electrical gas valves are designed to shut off the flow of either The electrical switches are intended for use with electric gas natural or LP gas to the appliances upon actuation of the regulat- valves, alarms, contactors, lights, contractor supplied electric ed release assembly.The valves are available in sizes of 3/4 in., power shut-off devices and other electrical devices that are 1 in., 1 1/2 in., 2 in., and 3 in.The valve is held open by an ener- designed to shut off or turn on when the system is actuated. gized solenoid and upon.system actuation, the switch contacts in Switches are available in kits: One Switch Kit, Part No. 423878, the regulated release assembly open, thus de-energizing the cir- Two Switch Kit, Part No. 423879, Three Switch Kit, Part No. cuit to the gas valve solenoid, causing the valve to close.Valves 423880,and Four Switch Kit,Part No.423881.Mounting hardware are available in 120 VAC and are UL Listed. and 12 in. (305 mm) long wire leads are provided with each kit. Part Max.Operating Each switch has a set of single-pole,double-throw contacts rated No. Description Pressure at: 13707 3/4 in.Solenoid Gas Valve(ASCO) 25 psi (1.7 bar) UL/cUL/CSA Rating ENEC Rating 13708 1 in.Solenoid Gas Valve(ASCO) 25 psi (1.7 bar) 250 VAC, 21A Resistive IE4T105N Approved 11550360 1 1/4 in.Solenoid Gas Valve (ASCO) 25 psi (1.7 bar) 250 VAC, 2 HP 250V,21A Resistive 13709 1 1/2 in.Solenoid Gas Valve(ASCO) 25 psi (1,7 bar) 125 VAC, 1 HP 8A Motor Load 13710 2 in.Solenoid Gas Valve(ASCO) 25 psi (1.7 bar) ►550363 2 1/2 in.Solenoid Gas Valve (ASCO) 5 psi (35 bar) 17643 3 in.Solenoid Gas Valve(ASCO) 5 psi (.35 bar) COMMON N_o. Valve A B Size in. (mm) in, (mm) 0 p 3/4 in. 3 5/16 (81.0) 3 5/8 (92.1) N.0 1 in, 5 (127.0) 6 27/32 (173.8) ► 1 1/4 in. 7 13/16 (198.4) 7 29/32 (200.8) 1 1/2 in. 5 (127.0) 5 19/32 (142.1) 2 in. 6 3/32 (78.6) 5 15/16 (150.8) ► ►2 1/2 in. 7 13116 (198.4) 7 29/32 (200.8) FIGUREQ29 3 in. 7 13/16 (198.4) 7 29/32 (200.8) ALARM INITIATING SWITCH - 1412 The Alarm Initiating Switch Kit, Part No. 428311, can be field mounted within the ANSUL AUTOMAN release.This switch must ►be used to close a supervised alarm circuit to the building main fire B alarm panel when the ANSUL AUTOMAN release actuates.This action will signal the fire alarm panel that there was a system actu- ation in the kitchen area. The switch kit contains all necessary { mounting components along with a mounting instruction sheet. The switch is rated 50 mA, 28 VDC. SPACER TOWARD ANSUL WHEN SPACER AND SWITCH A AUTOMAN PROPERLY MOUNTED,HIS DIVIDES FIGURE 27 MUST BE BETWEEN THE ► \ /N.O.AND N.C.TERMINALS �MANUAL RESET RELAY COM,�• f ►The Manual Reset Relay,Part No.426151,is required when using �.\ 19 N.C. an electrical gas valve shut-off system.After the electric gas valve •� has closed, either due to system actuation or power failure, the ��- valve cannot be re-opened, allowing gas to flow, until the reset \` relay button is manually pressed, re-energizing the circuit. The o •\ v� reset relay is available 120 VAC.The manual reset relay is also •� N.C.recommended for electrical shut down. �l •� '� ALARM INITIATING SWITCH ® FIGURE 30 ► FIGURE 28 OIX68v SECTION III-SYSTEM COMPONENTS ► UL EX.3470 ULC CEx747 Page 3-1 1 4-1-06 - REGULATOR TEST KIT HOSEIGROMMET PACKAGE The Test Kit Assembly(Shipping Part No.56972)is required to test The Hose/Grommet Package,Part No.418511.consists of a 24 in. the regulator setting and nitrogen flow during 12-year maintenance rubber hose and 2(two)grommets.This package is required when examinations. This will ensure that the regulator is functioning mounting an AUTOMAN Regulated Release (or Regulated properly. Actuator) and a tank enclosure (or tank bracket) side by side in either a manifolded system or an independent piping system. BURSTING DISC The R-102 Bursting Disc is installed in the tank adaptor assembly. The bursting disc eliminates the siphoning of the agent up the pipe during extreme temperature variations. The bursting discs are available in packs of 10, Part No.417911. ' FIGURE 31 001 M FUSIBLE LINK � Select correct UL Listed fusible link(s)for installation in detector(s) according to the temperature condition chart below: ► FIGURE 33 060172 K STYLE Fusible Link To Be Used NOZZLE AIMING DEVICE Fusible Shipping Where The Nozzle Aiming Device, Part No.431992, is available to prop- Link Assembly Temperature Temperature eriy aim each nozzle to the correct aiming point. The device Part No. Part No. Rating Does Not Exceed clamps to the nozzle and emits a small laser light that reflects on 415739(1) 415739 (1) 165'F (74'C) 100'F (38'C) the surface that it is aiming at.The nozzle can then be rotated to 415740(1) 415740(1) 212'F(100-C) 150'F (66'C) point at a predetermined aiming point and then tightened to hold 415741 (1) 415744(25) 280'F(138 'C) 225'F(107'C) that angle.The aiming device adaptor attaches to the nozzle.The ►415742(1) 415745(25) 360'F(182'C) 290'F(143 'C) shipping assembly consists of the aiming device and the adaptor. -415743(1) 415746(25) 450'F(232 'C) 360'F(182'C) MIL STYLE Fusible Link To Be Used Fusible Shipping Where R Link Assembly Temperature Temperature \ Part No Part No. Rating Does Not Exceed— • ADAPTOR 550368(1) 551522(10) 165'F (74'C) 100'F (38'C) NOZZLE 550365(1) 551523(10) 212'F(100'C) 150'F (666'C) AIMING 550366(1) 551524(10) 280'F(138'C) 225'F(107'C) DEVICE FIGURE 34 ►550009(1) 551525(10) 360'F(182*C) 290'F(143'C) ON2O 550367(1) 551526(10) 450'F(232'C) 360-F(182-C) STAINLESS STEEL ACTUATION HOSE 56816(1) 551527(10) 500'F(260 'C) 400'F(204'C) ► 56816(1) 73867(25) 500'F(260'C) 400'F(204'C) The Stainless Steel Actuation Hose is used to connect the actua- tion line compression tees between each pneumatic actuator.The hose has the same thread, 7/16-20, as the fittings.The actuation Ohose allows flexibility between the AUTOMAN and each regulated actuator. Hose Part No. Length Couplings )(TEMPERATURE 31809 16 in. 41 cm 7116-20 x 7/16-20 Females 4M 1KM RATING STAMPED ON 32335 20 in.(51 cm) 7/16-20 x 7/16-20 Females FUSIELE LINK BODY 32336 24 in.(61 cm) 7116-20 x 7/16-20 Females O ►430815 42 in.(107 cm) 7/16-20 Female x 114 in.NPT Fitting Part No. Description K STYLWIM aaalri ML I71 TYLE 000im 31810 Male Elbow (7/16-20 x 1/4 in.NPT) FIGURE 32 31811 Male Tee (7/16-20 x 7/16-20 x 1/4 in.NPT) ►415371 Tee(7/16-20 x 1/8 in.Male NPT x 1/8 in.Female NPT) MAXIMUM REGISTERING THERMOMETER 32338 Male Straight Connector(7/16-20 x 1/4 in.NPT) ►25627 1/4 in.Check Valve The Maximum Registering Thermometer, Part No. 15240, is used to indicate the highest normal temperature for the protected area. Once this is established, the correct rated fusible link can be - chosen. k:= m2a 7/16-20 7/16-20 ► FIGURE 35 000.ID SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-1 4-1-06 REV.6 SYSTEM DESIGN GENERAL INFORMATION The ANSUL R-102 Restaurant Fire Suppression System may be 1,Nozzles must be located 2-8 in.(5.20 cm)into the center of the used on a number of different types of restaurant cooking appli- duct opening, discharging up.See Figure 1. anhes and hood and duct configurations.The design information listed in this section deals with the limitations and parameters of this pre-engineered system.Those individuals responsible for the design of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. ' The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used, • Both systems must actuate simultaneously. is-20 Cm) ` • Each system must be designed and installed per its appropri- ate manual. morn • Adjacent appliances requiring protection must be protected 2.In installations where a UL listed damper assembly is with the same type of system, either R-102 or PIRANHA, employed, the duct nozzle can be installed beyond the 8 in, unless the center-to-center spacing between the adjacent (20 cm) maximum, to a point just beyond the damper assem- R-102 and PIRANHA nozzles is no less than 36 inches. bly that will not interfere with the damper.Exceeding the maxi. • When appliances are protected with R-102 nozzles, the hood mum of 8 in.(20 cm) in this way will not void the UL listing of and connecting duct above those appliances cannot be pro- the system_ tected with PIRANHA nozzles. 3.Previously listed 3 flow number and 5 flow number duct pro- Mixing systems in a common plenum is not allowed. tection detailed in earlier published manual, Part No.418087- One of the key elements for restaurant fire protection is a correct 06,can also still by utilized. system design.This section is divided into ten sub-sections:Noz [DUCT SIZES UP TO 50 IN.(127 cm) zle Placement Requirements,Tank Quantity Requirements, Actu- ERIMETER/16 IN.(41 cm) DIAMETER ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- 0 • One 1 W nozzle (Part No.419336)=one flow number tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements,Electrical Switch Requirements, and 50 in.(127 cm)perimeter maximum Pressure Switch Requirements. Each of these sections must be 16 in.(41 cm)diameter maximum completed before attempting any installation. System design sketches should be made of all aspects of design for reference DUCT SIZES UP TO 100 IN,(254 cm) during Installation. PERIMETER/32 IN.(81.3 cm) DIAMETER NOZZLE PLACEMENT REQUIREMENTS One 2W Nozzle (Part No.419337)=two flow numbers This section gives guidelines for nozzle type, positioning, and 100 in.(254 cm) perimeter maximum quantity for duct,plenum,and individual appliance protection.This • 32 in.(81.3 cm)diameter maximum section must be completed before determining tank quantity and piping requirements. A 2WH nozzle (Part No, 78078) must be substituted for a 2W nozzle for any installation using Option 2 of the 1.5 gallon sys- Duct Protection—Single Nozzle tem coverage(duct and plenum protection only).A 2WH nozzle All duct protection is UL listed without limitation of maximum duct is limited to a maximum of 75 in.(190 cm) perimeter or a maxi- length (unlimited length).This includes all varieties of ductworks mum diameter of 24 in.(61 cm)of coverage. both horizontal and vertical including ducts that run at angles to The chart below shows the maximum protection available from the horizontal and ducts with directional bends. each duct nozzle. The R-102 system uses different duct nozzles depending on the Part 3.0 Gallon 1.5 Gallon size of duct being protected. Description No. System System 2W Nozzle 419337 Maximum Maximum 100 in.(254 cm) 100 in.(254 cm) Perimeter Perimeter 1 W Nozzle 419336 Maximum Maximum 50 In.(127 cm) 50 in.(127 cm) Perimeter Perimeter SECTIOm IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-3 10-1.02 REV,4 ►Duct Protection—Multiple Nozzle(Continued) When working with Chart 2, one half of the quantity of nozzles determined must be equally positioned in the top half of the area DUCT SIZES GREATER THAN 135 IN.(343 cm) PERINIETER of the duct and the remaining half of the nozzles must be posi- tioned in the bottom half of the duct area. • Ducts over 135 in. perimeter must be modularized using 217V nozzles(Part No.419337) Example:The duct to be protected has a Side "A"of 40 in.and a Side"B"of 60 in.Referring to the design chart, this duct requires No round duct option available 4 nozzles.One half of 4=2.Therefore,2 nozzles must be equally • Follow the design chart to determine maximum module size for positioned in each of the two duct areas.See Figure 3. each 2W nozzle SIDE"B" When determining number of nozzles required, it is sometimes 30 IN.try mm) ao IN.(75 mm) an advantage to check the chart using the shortest side as Side "A" and then recheck it using the longest side as Side "A".This 20 IN. comparison may reveal a need for a lesser quantity of nozzles (51 mm) one way versus the other way. SIDE N. When working with Chart 1, the quantity of nozzles determined must be equally divided within the duct area. 20 IN. (51 mnl) ly 601N. _I �1 CHART N0.1 (152 m(n) B ' FIGURE 3 M5523 A SIDE"B" 25 26 27 2d 29 30 31 J2 33 34 35 36 37 38 J9 40 41 .11 43 3.1 45 46 17 49 19 50 51 52 53 54 i6 56 7 58 59 60 C 62 63 o4 65 56 47 6a d9 TO 71 72 4 5 6 7 e s ,6 1II 12 — 13 14 IS 16 17 2 16 SIDE 19 "A- 20 21 2 23 24 25 26 2a 23 30 31 32 „ 4 3s 38 5 1 6 1 7 CHART NO.2 B A NOTE:NOZZLE QUANTITIES LISTED IN CHART 2 MUST BE EQUALLY DIVIDED INTO EACH OF THE TWO DUCT MODULES. 36 37 36 39 41 2 4 42 43 G W V 45 47 _�_ SECTION IV - SYSTEM DESIGN UL EX.3470 ULC CEX747 Page 4-5 4-1-06 REV.4 Plenum Protection ► Option 2:The 1 W nozzle must be placed perpendicular, 8-12 in. �T fe-R 0 system uses the 1 W Nozzle (Part No.419336) or the (20-30 cm) from the face of the filter and angled to the rdh!Riezzie (iPart No.419335) for plenum protection.The 1W noz- center of the filter.The nozzle tip must be within 2 in. `zle'tl is stamped with I and the I nozzle tip is stamped with (5 cm) from the perpendicular center line of the filter. 1N, indicating they are one-flow nozzles and must be counted as See Figure 8. one flow number each.When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. 12 IN.(30 cm) MAXIMUM IN VERTICAL PROTECTION-GENERAL '0 (tOcm) t�One I nozzle will protect 4 linear feet (1.2 m) of plenum.The f a IN.(20 cm) maximum distance from the end of the hood to the first and last / MINIMUM nozzle must be no more than 2 ft.(.6 m).After the first nozzle,any additional nozzles must be positioned at a maximum of 4 ft.(1.2 m) NOZZLE TIP J apart down the entire length of the plenum.The plenum width must MUST BE WITHIN ►not exceed 4 ft.(1.2 m).(The 1 W nozzle can be used on single or THIS AREA V-bank filter arrangements.)See Figure 6. 2 Fr.(.6m) MAXIMUM -- °Fr.(t.2 m) FIGURE 8 MIAXIMUMI 0002co 4FT.(1.2mJ� �4FT.(1.2m) 2 FT.(.6 m) IA"' MAXIMUM MAXIMUM HORIZONTAL PROTECTION-OPTION 1 MAXIMUM 1 N NOZZLE-PART NO.419335-SINGLE BANK PROTECTION One 1 N nozzle will protect 10 linear feet(3.1 m)of single filter bank plenum.The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length.The nozzle must be ►positioned 0-6 in.(0-15 cm)from the end of the hood to the tip of the nozzle.See Figure 9. 2-4 IN, 10 FT.(3.1 m) FIGURE 6 (5—loan) MAXIMUM 000� ►When protecting plenums with the 1 W nozzle, two options of cov- erage are available: ►Option 1:The 1 W nozzle must be on the center line of the single CWNI or "V" bank filter and positioned within 1-20 in. (2.5-51 cm) above the top edge of the filter. See PFIGURE9 Figure 7. 20 IN.(51 cm) MAXIMUM 1 IN.(2.5 cm) MINIMUM i I - 20 IN.(51 cm) MAXIMUM 1 IN.(2.5 cm) MINIMUM - FIGURE 7 SECTION IV - SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-7 10-1-02 REV.3 i Appliance Protection The following pages detail types of appliance protection. Each design requires several factors:correct nozzle choice,correct noz- zle height above hazard, correct nozzle location and correct aim- ing point. Fryer-Single Nozzle Protection 1. Design requirements for fryers are broken down into two types. A. FRYERS WITHOUT DRIPBOARDS If the fryer does not include a dripboard, measure the internal depth (horizontal dimension from front to back) and length of the frypot. B. FRYERS WITH DRIPBOARDS If the fryer includes any dripboard areas, measure both the internal depth (horizontal dimension from front to back)and length of the frypot portion, and then measure the internal depth and length of the overall hazard area including any dripboard areas. 2. Using Table, "Maximum Cooking Area Dimension - Single Nozzle Fryer Protection,"determine which nozzle is needed to protect the fryer based on the maximum dimensions listed. A. If the fryer does not include a dripboard, use the maxi- mum dimensions listed in the first column of the table to select the correct nozzle. B. If the fryer includes any dripboard areas, use both the maximum frypot dimensions in the first column of the table,and the maximum overall dimensions in the second column of the table to select the correct nozzle.None of - the maximum dimensions in either column may be exceeded. 3. If either the maximum frypot or the overall sizes are exceed- ed,an additional nozzle(s)will be required.Refer to the mul- tiple nozzle requirements. Example:A fryer with a dripboard. The inside of the frypot without the dripboard measures 18 in,in depth x 18 in.in length(46 cm x 46 cm)and the inside of the overall area including the dripboard measures 18 in.in depth x 24 in.in length(46 cm x 61 cm).From the Table Maximum Cooking Area Dimension - Single Nozzle Fryer Protection,"either the 3N or the 290 nozzle should be select- ed to protect the fryer, depending on the maximum nozzle height above the fryer and the positioning requirements allowed.Refer to appropriate Figures. r \ SECTION IV — SYSTEM DESIGN! UL EX.3470 ULC CEx747 Page 4-9 4-1-06 REV.8 I Fryer—Single Nozzle Protection (Continued) Maximum Area Dimensions—Single Nozzle Fryer Protection (Continued) Max.Size Max.Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location 19.5 in.x 19 in. 19.5 in.x 25 3/8 in. 290 13 in.to 16 in. See Figure 17 (50 cm x 48 cm) (50 cm x 65 cm) (33 to 41 cm) 19.5 in.x 19 in. 19.5 in.x 25 3/8 in. 31N See Figure (50 cm x 48 cm) (50 cm x 65 cm) 18 See Figure 18 • 18 in.x 18 in. 18 in.x 27 3/4 in. 3N 25 in.t0 35 in. See Figure 19 ►(46 cm x 46 cm) (46 cm x 70.5 cm) (64 cm to 89 cm) I � I I I I i I TOP OF FRYER I I I j i , I FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD ARE s 3 IN ROVT w AONT — ����— (7.6 cm)FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND t 1 ��+ RIGHT-TO-LEFT aywoa IN.(25 cm)FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD AND CENTERLINE AIMED AT THE MIDPOINT OF THE COOKING AREA- FRYER'NITHOUT DRIPBOARD FRYER WITH DRIPBOARD FIGURE 17 NOTE: 3N NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE cayss AREA WITHIN THE FRONT HALF OF THE FRY POT AND AIMED AT THE CENTER. FIGURE 19 34 IN.(86 cm(MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA k� 21 In.(53 cm) 1` I MINIMUM VERTICAL I NOZZLE 1 HEIGHT I + I I I FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR V4ITHIN PERIMETER OF COOK- ING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 18 ca.Me� SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-11 4-1-06 REV.8 Fryer—Multiple Nozzle Protection (Continued) Nlaxlmum Area Dimension—Multiple Nozzle Fryer Protection Max.Size Module Max.Size Module Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location Full or Split Vat Full or Split Vat 21 in.x 210 in.2 21 in.x 294 in.2 230 27 in.to 47 in. See Figure 21 (53 cm x.14 m') (53 cm x.19 m2) (69 cm to 119 cm) Full or Split Vat Full or Split Vat 21 in.x 210 in.2 21 in.x 294 in.2 245 20 in.to 27 in. See Figure 21 (53 cm x.14 m2) (53 cm x.19 m2) (51 to 69 cm) ' Full or Split Vat Full or Split Vat 121 in.x 210 in.2 21 in.x 294 in.2 290 13 in.to 16 in. See Figure 22 (53 cm x.14 m2) (53 Cm x.19 m2) (33 to 4(1 cm) 25 3/8 x 370.5 2 2 25 3/8 x 495 in2 290 13 in.to 16 in. See Figure 22 (65 cm x.24 m ) (65 cm x.32 m ) (33 to 41 cm) ' Full or Split Vat Full or Split Vat 26 1/2 in.x 203 in.2 26 1/2 in.x 384 1/4 in.2 290 16 in.to 27 in. See Figure 22 (67 cm x.13 m2) (67 cm x.25 m2) (41 to 69 cm) 25 3/8 x 370.5 in2 25 3/8 x 495 in2 31\I See Figure 23 See Figure 23 (65 cm x.24 m2) (65 cm x 0.32 m2) 27 314 x 324 in.2 27 3/4 x 497 in2 3N 25 in.to 35 In. See Figure 24 (70.5 cm x.21 m2) (70.5 cm x.32 m2) (64 cm to 89 cm) 34 IN.(86 cm)MAXIMUM DIAGONAL - - 3`�, - DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA -T� j I I I I i 21 in.(53 cm) MINIMUM I VERTICAL I I� NOZZLE I I 1 HEIGHT I 'j oazDt �ILI ec°xla FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD PERIMETER OF THE MODULAR IT IS PROTECTING AND AIMED AT THE MIDPOINT OF POSITION NOZZLE TIP ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE THAT RESPECTIVE MODULE AREA. MODULE IT IS PROTECTING AND AIM AT THE MIDPOINT OF THAT MODULAR AREA. FIGURE 23 FIGURE 21 i I I ` AIM POINT I 1 r I 1 , `j1,�1 (DIAGONAL � ( I I AIM POINT(DIAGONAL I I I I, , CENTER OF F ^—� F`� , I I , CENTER OF MODULE 1 I I I I I MODULE 1 COOKING AREA) COOKING I i I AREA) I I I RIGHT-TO-LEFT I 1 1 I RIGHT-TO• 1 ' 1 CENTERLINE I I ( LEFT r. , _ ' CENTER. LINE rn�zz�c _ oozru FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARO FRYER WITHOUT DRIPBOARO 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE RESPECTIVE MODULAR THE 3N NOZZLEFRYER WITH DRIPBOARD AREA m 3 IN. (7.6 cm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE TIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE PERIMETER AND FORWARD OF THE MODULE AND t 1 IN.(2.5 cm)FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF NOZZLE T MUST B CENTERLINE OF THE COOKING AREA.THE AIMING POINT OF THE NOZZLE THEM AND AIMED AT THE MIDPOINT OF THE MODULE ,MUST [AT THE DIAGONAL CENTER OF THE MODULAR COOKING AREA. FIGURE 22 FIGURE 24 SECT10P1 IV - SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-13 4-1-06 REV.6 - Range Protection 1-Flow Nozzle When this type of hazard is equipped with a back shelf located The R-102 system uses five different nozzles for the protection of above the range top, two protection options are available: One ranges, TWO of the design options require a one-flow nozzle and requires a IF nozzle, Part No. 419333, and the other option three of the design options require two-flow nozzles. requires a 260 nozzle, Part No.419341. NOTICE Option 1: 1 F Nozzle:When using the 1F nozzle for range protec- A 13 in.(33 cm)diameter wok pan is the largest tion with or without back shelf, the maximum length of wok size that can be protected on ranges. the burner grates being protected must not exceed When protecting hot top ranges, the entire 28 In. (71 cm) and the maximum area of the burner grates must not exceed 336 sq.in.(2168 sq.cm).See cooking surface must be protected. Figure 27 for nozzle location details. Range Protection(1-Flow Nozzle) IrNOZZLE Single and multiple burner ranges can be protected using a IN SHELF CAN OVERHANG BURNER(S) nozzle, Part No.419335.The nozzle tip is stamped with IN, indl- BY A MAXIMUM OF 11 IN.(28 cm) cating that this is a one-flow nozzle and must be counted as one flaw number. When using this nozzle for range protection,the maximum length I 20IN. of the burner grates being protected with a single nozzle must not AIM (51 cm) exceed 32 in.(81 cm)and the maximum area of the burner grates 1102-122 cm) I POINT MINIMUM must not exceed 384 sq.in.(2477 sq.cm) per nozzle. When protecting a range, the 1 N nozzle must be located a maxi- mum of 10 in. (25.4 cm) from each burner grate centerline and must be aimed at the center of the cooking surface.See Figure 26. 1.1 IN. (35.6 cm) 12IN. 14IN MAXIMUM — - (30.5 cm) (35.6 cm) FRONT TO REAR / MAXIMUM CENTERLINE MAXIMUM I 1 F NOZZLE LOCATED OVER FRONT EDGE OF BURNER GRATE AND ORIENTED SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER GRATE FRONT TO REAR CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE. 4o IN. - - - FIGURE 27 102 CM) T _�\ T , , � Avis Option 2: 260 Nozzle:When using the 260 nozzle for range pro- (76 cN.30 tection with or without back shelf,the maximum length n) ( 1 of burner grates being protected must not exceed r 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. cm). Nozzle must be located on the front edge of the burn- er grates and aimed at a point 10 in.(25 cm)from the back edge of the burner grates.Nozzle must be mount- ed 30 to 40 in. (76 to 102 cm) above the hazard sur- face.See Figure 28. 260 NOZZLE 10 IN. A NERS) MA IM cm) MAXIMUM 1 32 IN. (B I cm) IN. iN MAXIMUM I5.7 cm) NOZZLE 30-40 IN. INIMUM (76-102 r-m) I AIMING I POINT 10 IN. (25 cm) 1 /MAXIMUM 0 IN. 25 cm)FROM ACK OF x�e�a URNER GRATES FIGURE 28 -- FIGURE 26 SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-15 10-1-02 REV 4 Range Protection 2-Flow Nozzle Medium Proximity Application(2-Flaw Nozzle):30 in.to 40 in. COOKING (76 cm to 102 cm)above the cooking surface. AREA The medium proximity application uses the 260 nozzle, Part No. 419341. r_ The nozzle tip is stamped with 260 indicating this is a two-flow nozzle and must be counted as two flow numbers. 2i cooKlrlc ►One 260 nozzle will protect a cooking area of 768 sq. in., + AREA ►(4955 sq.cm)with a maximum dimension of 32 in.(81 cm). 260 NOZZLE TIP When using this nozzle for range protection, the nozzle must LOCATION CENTEROF COOKING be pointed vertically down and positioned as shown in Figures SURFACE '31 and 32. ► 10 IN.(25.4 cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO 260 NOZZLE TIP LOCATION CENTER OF ANY COOKING _ CENTERLINE OF COOKING SURFACE ► BURNER GRATE AREA 260 LOCATION A TIP � LOCATION C CEO JTER I 40 IN. SURFACE COOKING .� COOKING SURFACE AREA (102cm) ► OR I ( MAXIMUM 10 IN.(25.4 cm) HEIGHT MAXIMUM FROM 0 . I I i OF 260 CENTERLINE OF 1 NOZZLE TO TIP CENTER OF ANY ► 81JRNER GRATE FIGURE 32 I 130 IN. xnrsa (76 cm) 1 MINIMUM NOTICE 1 HEIGHT ► Four burner grates shown in Figure 32.For sin- F 260 NOZZLE gle or double burner grates, locate nozzle at ( I I TIP center of cooking surface. I I I O O O O ' FIGURE 31 SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-17 10-1-02 REV.5 - Griddle Protection 1-Flow Nozzle The R-102 system uses four different nozzles for the protection of griddles. One of the applications requires a 1-flow nozzle and I I NOZZLE LOCATION of the applications require a 2-flow nozzle. I I o-2 IN.(0-s C„) I I I INSIDE PERIMETER 1 40 IN. High Proximity Application:35 in.to 40 in.(89 to 102 cm)above —►I OF COOKING SURFACE I I (102 cm) the cooking surface. I I I MAXIMUM I I HEIGHT This high proximity application uses the I nozzle, Part No. I oF1N 419335. i t NOZZLE TIP The nozzle tip is stamped with 1 N indicating this is a one-IIGw noz- I I MI IN.UM cm) r I MINIMUM zle and must be counted as one flow number. I I I I HEIGlfT EDGE I I I t OF 1,14 One IN nozzle will protect a maximum cooking area of 1080 sq. OF—.I I f NOZZLE TIP I I I I in.(6968 sq.cm)with the maximum longest side of 36 in.(91 cm). COOKINGsuRFACE I I I I When using this nozzle for griddle protection,the nozzle must be positioned along the cooking surface perimeter to a maximum of 2 in.(5 cm)inside the perimeter, and aimed to the midpoint of the ►cooking surface.See Figure 35 and 36. NOTICE 6 FIGURE 3 When using this type of griddle protection, only Q 36 5 flow numbers are allowed on a 1.5 gallon sys tem and only 11 flow numbers are allowed on a 3 gallon system. I r MIDPOINT OF COOKING SURFACE I I I j I I � � I I IN NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN.(0-5 cm)OF COOKING SURFACE EDGE.NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. ' FIGURE 35 �cea� SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-19 10-1-02 REV.3 2-Flow Griddle Protection(Continued) Option 2—Nozzle Perimeter Located •High Proximity Application: 30 in. to 50 in. (76 cm to 127 cm) COOKING AREA above the cooking surface, This high proximity application uses the 260 nozzle, Part No. --- 419341. r MIDPOINT of I COOKING SURFACE The nozzle tip is stamped with 260 indicating this is a two-flow i �� f nozzle and must be counted as Nvo flow numbers. cooKlrlG One 260 nozzle will protect a maximum cooking area of 1440 sq. I AIM POINTAREA � in.(9290 sq,cm)with a maximum dimension of 48 in.(122 cm).When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to 2 in. (5.1 cm) inside perimeter,and aimed at the center of the cooking Surface.See Figure 39 and 40. 260 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN.(0-5 cm)OF COOKING SURFACE EDGE.NOZZLE I I P10771 F LOCATION MUST BE AIMED AT MIDPOINT OF 0-2 IN.(0-5 cm) f l COOKING SURFACE. INSIDE PERIMETER I 50 I.I.OF COOKING SURFACE I I (127 cm) FIGURE 40 I I MAXIMUM eccx+' I I I HEIGHT OF 260 I I I I NOZZLE TIP I 30 IN.(76 cm) j I MINIMUM EDGE I I i OF 260r OF- f I i NOZZLE TIP COOKING SURFACE I I ecoz+� FIGURE 39 cee+x� Z SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4.21 10-1.02 REV.3 2-Flow Griddle Protection(Continued) Option 2—Nozzle Perimeter Located (Continued) Low Proximity Application: 10 in. to 20 in. (25 cm to 51 cm) above the cooking surface. The low proximity application uses the 2120 nozzle, Part No, 419343. The nozzle tip is stamped with 2120 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 2120 nozzle will protect a maximum cooking area of 1440 sq. in. (9290 sq. cm) with a maximum dimension of 48 in. (122 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the perimeter to 2 in.(5.1 cm)Inside perime- ter, and aimed at the center of the cooking surface. See Figure '43 and 44. I 1 NOZZLE LOCATION I I 0-2 IN.(0-5cm) I I I INSIDE PERIMETER I 20 IAf. OF COOKING SURFACE I I (51 cm I I t l HEIGHT MAXIMUM OF 2120 I I I i NOZZLE TIP I i I 101N.(25 cm) MININIUM HEIGHT OF 2120 NOZZLE TIP II iI acazu EDGE OF COOKING SURFACE ' FIGURE 43 000211 �— COOKING AREA r CENTER OF COOKING SURFACE I COOKING 1 AREA AIM POINT 1 2120 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0—2 IN.(0—5 cm)OF COOKING SURFACE EDGE NOZZLE MUST 9E AIMED AT CENTER OF COOKING SURFACE. ° FIGURE 44 OG1.:1I SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-23 4-1-06 REV 7 Overhead Chain Broiler Protection (Continued) Example No. 1 —Internal broiler size is 24 in. long x 20 in. wide Upright/Salamander Broiler Protection (61 x 51 cm), with an opening of 16 in. x 16 in.(40.6 x 40.6 cm). The R-102 system uses two 1/2N Nozzles Part No.419334)for all upright/salamander broiler protection.The nozzle tip is stamped To determine minimum opening size, multiply the 1/2N,indicating that this is a half-flow nozzle.A pair of these noz- internal length and the internal width by 0.6: zles will equal one flow number. ' Length of opening—24 in.x 0.6= 14.4 in. Two 1/2N nozzles will protect a maximum hazard area (internal (61 cm x 0.6=36.6 cm) broiler chamber)of 30 in.x 32.5 in.(76 cm x 82.5 cm).These noz- Width of opening—20 in.x 0.6= 12.0 in. zles must always be used in pairs on an upright/salamander broil- (51 cm x 0.6=30.5 cm) er.One nozzle must be positioned above the grate and pointed at the back opposite corner of the broiler chamber.The second noz- The minimum allowable opening for overhead protec- zle must be pointed down into the center of the drip pan through tion would be 14.4 in.x 12.0 in.(36.6 x 30,5 cm). ►the open slot.See Figure 50. This example would be acceptable for overhead pro- Note:If metal blow-off caps are required for upright broiler or sala- tection. mander broiler protection, use (2) two IN nozzles, Part No. Example No.2—Internal broiler size is 30 in, long x 24 in.wide 419335,instead of 1/2N nozzles. (76 x 61 cm) with an opening of 22 in, x 12 in. (56 x 30 cm). SALAMANDER BROILER To determine minimum opening size,multiply internal length and internal width by 0,6: Length of opening—30 in.x 0.6= 18.0 in. (76 cm x 0.6=45.7 cm) Width of opening—24 in.x 0.6= 14.4 in. (61 cm x 0.6=36.6 cm) Minimum allowable opening for overhead protection would be 18 in.x 14.4 in.(45.7 x 36.6 cm). Because this broiler has an opening of 22 in.x 12 in., the 12 in.width is below the minimum allowable cal- culated dimension of 14A in.(36.6 cm) and therefore would not be acceptable for overhead protection. ►Upright/Salamander Broiler Protection The R-102 Restaurant Fire Suppression System uses one IN UPRIGHT BROILER Nozzle, Part No.419335,for upright/salamander broiler protection. BROILER CHAMBER The nozzle tip is stamped with 1 N,indicating that this is a one-flow nozzle. One 1 N nozzle will protect a maximum hazard area(internal broil- er chamber)of 16 in.(41 cm)deep x 29 in.(74 cm)wide. The single IN nozzle must be located directly in line with either vertical edge of the broiler opening,6 In.(15 cm) to 12 in.(30 cm) in front of the broiler, and 0 in.to 12 in. (30 cm) above the top of the broiler.The nozzle must be aimed at the center of the broiler opening.See Figure 49. DRIP VERTICAL EDGE I PAN OF BROILER L__J OPENING 1N NOZZLE �{ (PART NO.419335) NOZZLE FRONT VIEW SIDE VIEW LOCATION ZONE 12 IN. (30 cm)N16 IN.(15 cm) B ./ 4) # yl, I aua:sz 6lN -- (15 cm) FIGURE 50 AIM AT CENTER AIM AT CENTER OF BROILER OF BROILER OPENING OPENING FIGURE 49 oon 2s SECTION IV — SYSTENI DESIGN UL EX.3470 ULC CEx747 Page 4-25 10-1-02 REV.6 Lava Rock(Ceramic)Char-Broiler Protection The R-102 system uses the 1 N Nozzle (Part No. 419335) for all Natural Charcoal Broiler Protection lava rock char-broiler protection. The nozzle tip is stamped with The R 102 system uses the 1N Nozzle (Part No.4I9335) for all 1 N, indicating that this is a one floav nozzle and must be counted natural charcoal broiler protection.The nozzle tip I as one flow number. p 's stamped with IN indicating that this is a one-flow nozzle and must be counted One 1 N nozzle will protect a hazard which has a maximum length as one flow number. of 24 in.(61 cm)and a total cooking area which does not exceed 312 in.. ((46 One IN nozzle will protect a hazard area which has a maximum 35 6 (2013 sq. cm).above The nozzle tip must be located 18 to length of 24 in. (61 cm) and a total cooking area which does not to 89 cm) above the hazard surface.When using this exceed 288 sq.in.(1858 sq.cm).The nozzle ti nozzle for lava rock (ceramic) char-broiler protection, the nozzle P must be located must be positioned anywhere along or within the perimeter of the 18 to 40 in.(46 to 102 cm)above the hazard surface.When using maximum cooking area and angled to the center.See Figure 52. this nozzle for natural charcoal broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the max- imum cooking area and aimed at the center of the cooking surface. COOKING ► See Figure 53. AREA COOKING I.� AREA The coverage of such appliances only applies when the depth of �-r� ►I the charcoal does not exceed 4 in. (10 cm). I l COOKING AREA i� CCOOOAKING I I I I 1 l I 0:72Etl C+A2ti0 I /) I � l I i 35 1N. I I (89 cm( MAXIMUM 1 , I i i 40 IN. (102 CM)18 IN A)CIMUM J MINIMUM ,ts, I I 1 tJ' 4 IV.tl0 cmJ t 18 IN. a»:s� MAXIMUM f I (46 cm) DEPTH 1 nurnnturvl I I I I I OW=53 FIGURE 52 FIGURE 53 SECTION IV — SYSTEM DESIGN UL EX.3.170 ULC CEx747 Page 4-27 10-1-02 REV.4 Wok Protection 2. A IN Nozzle, Par;No.419335,will protect a wok 11 in.(28 cm) The R-102 system uses two different nozzles for the protection of minimum diameter up to 24 in. (61 cm) maximum diameter. woks. The wok depth must be no less than 3 in. (8 cm) and no greater than 6 in.(15 cm).The nozzle tip is stamped with 1 N 1. A 260 nozzle, Part No. 419341, will protect a wok 14 in. indicating that this a one-flow nozzle and must be counted as (36 cm) minimum diameter up to 30 in. (76 cm) maximum one flow number.When using this nozzle,the nozzle must be diameter. The wok depth must be no less than 3.75 in, positioned anywhere along or within the perimeter of the wok, (9.5 cm) and no greater than 8 in.(20 cm). aimed at the center, 30 in.to 40 in.(76 to 102 cm) above the The nozzle tip is stamped with 260 indicating that this is a hero- ' hazard surface,as shown in Figure 57. flow nozzle and must be counted as two flow numbers. NOTICE When using this nozzle, the nozzle must be positioned as When using this type of wok protection, only ' shown in Figure 56. 5 flow numbers are allowed on a 1 1/2 gallon NOZZLE MUST B system, and only 11 flow numbers are allowedE POSITIONED WITHIN 1 IN.(2 cm)RADIUS on a 3 gallon system. OF THE CENTER OF THE WOK,POINTED VERTICALLY DOWN g y I I IA (102 cm) I 260 NOZZLE , \ I 30 IN. (76 cm) MINIMUM DEPTH 3.0 IN,(7.6 cm) I I MAXIMUMN.(15 DEPTH 6 0 1P1.(15 cm) 1 (8 — 1 .1 1 I IN.(26 cm)MINIMUM DWMETER (89—1 L1 tilt) MINIMUM DEPTH 3.75 IN.(9.6 cm) 1 24 IN.(61 rm)MAXIb1UM DIAMETER MAXIMUM DEPTH 0 IN.(20 cm) I FIGURE 57 e� Wml I 14 IN,(35.6 cm)MINIMUM DIAMETER 30 IN.(76.2 cm)MAXIMUM DIAMETER FIGURE 56 W0261 SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-29 4-1-06 REV.5 Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping— HsIuaal Dimensions Quanti Heights Part No Flow No _ Fryer(Non-Split Maximum Size Vat Only)' (with drip board) 21 in.(53 cm) x 14 in.(36 cm) (Fry Pot must not exceed 15 in.x 14 in. (38 cm x 36 cm)) High Proximity 1 27—47 in. 419339 230 Medium Proximity 1 20—27 in. 419340 245 Maximum Size (with drip board) 25 3/8 in.(64.4 cm) x 19 1/2 in.(49.5 cm) (Fry pot side must not exceed 19 1/2 in. (49.5 cm)x 19 in. (48.2 cm) High Proximity 1 21 —34 in. 419338 3N Low Proximity 1 13— 16 in. 419342 290 Maximum Size (with drip board) 18 in.(45.7 cm) x 27 3/4 in.(70.5 cm) High Proximity 1 25—35 in. 419338 3N (64-89 cm) Fryer(Split or Maximum Size Non-Split Vat) (with drip board) 14 in.(36 cm)x 21 in.(53 cm) 1 13—16 in. 419342 290 Low Proximity (33—41 cm) Fryer(Split or Maximum Size Non-Split Vat) (with drip board) 14 1/2 in.(37 cm)x 26 1/2 in.(67 cm) 1 16—27 in. 419342 290 Medium Proximity (41 —69 cm) Range Longest Side 1 30—40 in. 419335 1 N 32 in.(81 cm) (76—102 cm) Area—384 sq.in. (2477 sq.cm) Longest Side 40—48 in. 419333 1 F 28 in.(71 cm) (102—122 cm) Area—336 sq.in. (With Backshelf) (2168 sq.cm) Longest Side(High Proximity) 1 40—50 in. 419340 245 28 in.(71 cm) (102—127 cm) Area—672 sq.in. (4335 sq.cm) , Longest Side (Medium Proximity) 1 30—40 in. 419341 260 32 in.(81 cm) (76— 102 cm) Area—768 sq.in. (4955 sq.cm) Longest Side(Low Proximity) 2 15—20 in. 419342 290 36 in.(91 cm) (38—51 cm) Area—1008 sq.in. (6503 sq.cm) ' For multiple nozzle orolection of singfe fryers.sre detailed information en Pages 4-7 Ihrough.1-1 I. ' SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-31 3-1-04 REV.6 Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping— Hazard i en5iDns Quantj.y haic s Part No. Flow No Wood Fueled Char-Broiler Longest Side—30 in.(76 cm) 1 14—40 in. 419338 3N Area—720 sq.in. (36—102 cm) (4645 sq.cm) Upright Broiler Length—32.5 in.(82.5 cm) 2 — 419334 1/2N Width—30 in.(76 cm) Salamander Length—32.5 in.(82.5 cm) 2 — 419334 1/2N Broiler Width—30 in.(76 cm) Wok 14 In.—30 in.(36—76 cm) 1 35—45 in. 419341 260 Diameter (89— 114 cm) 3.75—8.0 in.(9.5—20 cm) Deep 11 In.—24 in.(28—61 cm) 30—40 in. 419335/417332 1 N/l NSS Diameter (76—102 cm) 3.0-6.O in,(8-15.2cm) Deep SECTION IV - SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-33 10-1-02. REV.5 SPECIFIC APPLICATION BY MODEL(Continued) Far West Hospitality Products Gas Fryer,Model PAR-1-20, Fryma' ter 14 KW-208V Electric Fryer,Model MACH 14 63000 BTU/hr Rating Series This specialized gas fryer can be protected with a single, 290 This specialized single vat electric fryer can be protected either nozzle, Part No.419342. with a single 230 nozzle, Part No.419339,located 27 in.to 47 in. The maximum dimension of the fry pot is 21 in. x 21 in. (53 x (69 cm to 120 cm)above the top surface of the fryer or with a sin- 53 cm), gle 245 nozzle, Part No.419340, located 20 in.to 27 in.(51 cm to The 290 nozzle must be located on the front-to-rear centerline and 69 cm)above the top surface of the fryer. 'aimed at the center of the cooking surface.See Figure 60. Either nozzle must be located anywhere along or within the perimeter of the cooking surface and aimed at the midpoint.See 4 1`2 IN- Figure 104.The maximum size of the fry pot(without drip board) (11.5 C) is 13 314 in.x 16 3/4 in.(35 cm x 42.6 cm) and the maximum size of the cooking surface (with drip board) is 13 314 in. x 20 7/6 in. (35 cm x 53 cm).The vat may be divided in half to make two split vats. 1 230 NOZZLE TIP OR 245 NOZZLE TIP ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE COOKING SURFACE AND AIMED AT THE MIDPOINT. 14 IN. (36 cm) 13 IN. I/ 20 7/3 IN. 230 P40ZZLE (33 cm) IM M MAXIMUM BACK OF / 2 i5 230 NOZZLE �_ r/ 27 IN.-47 IN, FRYER I �I I NOZZLE (69 cm—120 cm) 13 3/4 IN. y,y I ABOVE TOP (35 cm) I I SURFACE MAXIMUM I OF FRYER SIDE VIEW OF FRYER 245 NOZZLE 120 IN.—27 IM (51 cm—69 cm) 290 NOZZLE LOCATED ON FRONT-TO-REAR CENTERLINE s 4.5 IN.(11.4 cm)FROM I ABOVE TOP SIDE TO SIDE CENTERLINE AND AIMED AT CENTER OF COOKING AREA. f I SURFACE OF I I FRYER I i 16 3h1 IN. 13 IN. (42.6 cm) 14 IN. (33 cm) MAXIMUM (36 cm) FIGURE 61 WU207 ' FIGURE 60 SECTION 1V — SYSTEM DESIGN UL EX.3,170 ULC CEX747 Page 4-35 4-1-06 REV.4 i I SPECIFIC APPLICATION BY MODEL(Continued) Nieco Broiler—Model 950,960,980 ► Nieco Broiler—Model 9015 (With or Without Catalytic • Nozzle Quantity/rype: (1) One 2VV nozzle, Part No.419337. Converter) • Nozzle Height: 20 in. (508 mm) above top of appliance. See Nozzle Quantity/Type: (2)Two 2W nozzles, Part No.419337. ► Figure 64a. Nozzle Height: 20 in. (508 mm) above top of appliance. See • Nozzle Location: 6 1/2 in. (165 mm) back from front edge of ' Figure 65. appliance.See Figure 64a. Nozzle Location for Large Chamber:6 1/2 in.0 65 mm)back Nozzle Alming Point: Aimed at center of opening.See Figure from front edge of appliance.See Figure 65. 64a. Nozzle Location for Small Chamber: Nozzle to be located 6 1/2 in.(165 mm) back from front edge of appliance and 12 in. ►Nleco Broiler—Model 950,960,980(with Catalytic Converter) (305 mm)over from large chamber nozzle. • Nozzle Quantity/Type: (2)Two 2W nozzles, Part No.419337. Nozzle Aiming Point for Large Chamber:Aimed at center of • Nozzle Height: 13 in. (330 mm) above top of converter. See opening.See Figure 65. Figure 64b. Nozzle Aiming Point for Small Chamber:Nozzle to be aimed • Nozzle Location: 6 112 in. (165 mm) back from front edge of 12 in.(305 mm)over from large chamber nozzle aiming point. ► appliance.See Figure 64b. Nozzle Aiming Point: Aimed at center of opening. See Figure ► 64b—Side View. / • Nozzle Aiming Point:Aimed at point 3 in.(76 mm)each side of I / center.See Figure 64b—Front View. 1_ (165 mm) ► i, CATALYTIC j CONVERTERS � 6 lit IN. I % o"1/2 IN. �(165 mm) �(165 mm) i i SIDE VIEY! I A(z)2N!NOZZLES SIDE VIEW SIDE VIEW Imo- 12 IN. yl (305 mm) ► I 20 IN. (508 mm) 218 NO771 E 2W NOZZLE ---- — -- -- (76 mm) yl�,(76 mm)19 IN, 20 IN. (330 mm) (506 mrn) I CENTERLINE OF LARGE OPENING I I FRONT VIEW ► FIGURE 65 CENTERLINE OF CENTERLINE OF LARGE OPENING LARGE OPENING FRONT VIEW FRONT VIEW ► FIGURE 64a FIGURE 64b SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-37 4-1-06 REV.4 SPECIFIC APPLICATION BY MODEL(Continued) Marshall Air—Model 2001 BK Multi-Chamber Broiler Marshall Air Electric Broiler—Model FR 14B AutoBroll • Nozzle Quantity/Type:(2)Two 1W nozzles, Part No.419347. Nozzle Quantity/Type: One 260 Nozzle(Part No.419341) • Nozzle Location:Front nozzle tip must be located 14 in.direct- Nozzle Height: 15—20 in.(38.1 —50.8 cm)above the top ly above the appliance,aligned with the front face and centerline of the broiler of the catalytic converter.The aim point is 4 in, forward of the c Nozzle Location: The nozzle must be entered above the front edge of the converter on the centerline. front edge of the be The rear nozzle tip is a mirror image of the front.The rear noz- Nozzle Aiming Point: Aimed at the center of the exhaust zle is located 14 in.vertically above the appliance,aligned with opening of the broiler the"rear"face and centerline of the catalytic converter.The aim point is 4 in.behind the"rear"edge of the converter on the cen- terline.System \� • System Limitation: Maximum of 5 flows fora 3.0 gallon sys- tem: Remaining flow points available may be used to protect 15-2oIN. other hazards. (38.1-50.8 cm) 24.25 IN.`. (61.6 cm) 24 IN. �14.50 IN. (61.0 cm) CENTERED ON CONVERTER I 34.69 IN. (36.8 cm) \ (88.1 Cm) CONVERTER Two 1 W NOZZLES \ �. G 48 IN. (121.9 cm) _ o O i aviaa FRONT VIEW NOZZLE ALIGNED WITH FRONT OF CONVERTER NOZZLE ALIGNED WITH NOZZLE ALIGNED WITH BACK FRONT OF CONVERTER, OF CONVERTER.AIMED AIMED 4 1,1.(102 mm)BACK 4 IN.(102 mm)FORWARD I IV! _14 NOZZLE NOZZLE _ f IN. 14 IN. FIGURE 69 (356 mm) • 4 IN, ON737 . (356 mm) (102 mm) + O O CIM w�as SIDE VIEW FIGURE 68 SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-39 4-1.06 REV,5 OVERLAPPING NOZZLE COVERAGE All appliance protection currently listed in the R-102 Design Hazard Zone Manual,Part No.418067,is also approved protection.Zone pro- The hazard zone is defined as a theoretical, flat and level,rectan- tection can be considered optional protection. gular surface, that includes all of the cooking hazards of the pro- TABLE 1 tected appliances under a common hood(s).The purpose of the hazard zone is to provide a means of locating the appliances and Overlapping Nozzle Coverage(Zone Protection) the overlapping nozzles, as well as aiming the overlapping noz- Appliance Type Maximum Cooking Hazard zles. The hazard zone measures 28 in. (711 mm) deep by the length of the cooking hazard(s).The centerline of the hazard zone Fryer 34 in.(864 mm) Deep x 5.8 sq,ft. must bisect the 28 in.(711 mm)depth(from front to back)and run (.54 sq.m) from right-to-left for the full width of the hazard zone. Griddle 30 in.(762 mm) Deep x Unlimited Length Overlapping Nozzle Appliance Protection Range 28 in.(711 mm) Deep x Unlimited Length Overlapping Nozzle Appliance Protection is defined as protection wok,Maximum 30 in.(762 mm)Diameter x 8 in. of cooking appliances by nozzles spaced uniformly at uniform ele (203 mm) Deep vations under a common hood(s).Overlapping protection of appli Wok,Minimum11 in.(279 mm) Diameter x 3 In. ances is continuous for the full length of the hood or divided when (76 mm) Deep group(s) of protected appliances are separated by counters or Braising Pan[Tilt 34 in.(864 mm) Deep x Unlimited appliances not requiring protection. Skillet' Length Full hood continuous protection is defined as overlapping noz- Lava Rock 32 in.(813 mm) Deep x Unlimited zle appliance protection that covers the appliance line-up located Char-Broiler Length under the total hood length.All appliances requiring protection are Charcoal Broiler 32 in.(813 mm) Deep x Unlimited Length the appliances under the hood that can be an Ignition source of (4 in.(102 mm)Maximum Fuel Depth) grease in the hood, grease removal device or the duct. Mesquite Wood 32 in. (813 mm) Deep x Unlimited Length Group protection is defined as overlapping nozzle appliance pro- Broiler (12 in.(305 mm) Maximum Fuel Depth) tection that protects individual hazard zones located under a com• Gas Radiant 36 in.(914 mm) Deep x Unlimited mon hoed.These "groups" of appliances may be separated by Char-Broiler Length appliances not requiring protection, such as steam equipment or work tables, or by dedicated appliance protection, such as sala- ' Electric Char-Broiler 34 in.(864 mm)Deep x Unlimited Length mander broilers. ► See Figure;72 for nozzle location ►See Figure 75 (full hood continuous protection) and Figure 76 (multiple group protection). Dedicated Nozzle Appliance Protection I r Appliance protection using dedicated nozzle coverage is defined —{'0-6 1N.(0-15 cm) PP P 9 g COVER MUST NOT I 1 as protection of cooking appliances with enclosed cooking haz- INTERFERE WITH I ! OF ards, such as upright broilers, which cannot be protected with EDGEAR - P DISCHARGE r overlapping nozzles and therefore must be protected with nozzles PATTERN r 40-45 IN dedicated to the appliance. ! (1-1.1 m) ' f General Design Limitations ( • Maximum depth of zone is 28 in.(711 mm). ,r The 245 nozzle,Part No.419340,is the only approved nozzle for ZONE overlapping(zone)protection. f Nozzle must be located 0 in.to 6 in.(0 mm to 152 mm) forward of zone centerline,aimed back at the zone centerline. • Nozzles must be spaced a maximum of 6 in. (152 mm) from ZONE CENTER LINE each end of hazard and then a maximum of 12 in.(305 mm)on center for the remaining overlapping nozzles until the complete hazard is covered. FIGURE 72 • For appliance hazard surfaces with listed protection exceed- ing the standard hazard zone of 28 in.(71 cm)in depth,the haz- ard surface(s)must be aligned with the back edge of the hazard zone,with the front edge overhanging the front edge of the zone. See Appliance Chart,Table 1, • For appliance hazard surfaces that exceed the listed protec- tion sizes, multiple zones must be utilized. Align entire hazard surface area within the multiple zones. All hood,duct,individual appliance,and piping limitations are as specified in the R-102 Design, Installation, Recharge and Maintenance Manual, Part No.418087. SECTION IV - SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-41 4-1-06 REV.4 OVERLAPPING NOZZLE COVERAGE(Continued) 2. When obstructions are located adjacent to appliance(s) pro- Overlapping Appliance Nozzle and Hazard Zone Locations- tected by overlapping nozzles, the overlapping appliance noz- Group Protection zle spacing must start with the appliance(s) adjacent to the ►1. For each group of protected appliances under a common obstruction.See Figure 77, hood(s),the overlapping nozzles must be located from right to 12 IN 12 IN, 12 IN. 12 IN. left so that each end nozzle is located a maximum of 6 in. 6 I (305 mm) (JOS mm) (1Q5 m1n) (a05 mm) (I52 mm) MAX. MAX. MAX. MAX. } (I52 mmJ (152 mm) inside the outside edge of the cooking hazard of MAX. + } } } each end appliance,and the inside overlapping nozzles must MAX. be located between the two end nozzles at a maximum spac- ing of 12 in.(305 mm).See Figures 75 and 76. OUTSIDE 12 IN.(305 mm)MAXIMUM EDGE OF SPACIOVERLAPPING G(S) G NOZZLES COOKING OVERLAPPING NOZZLES HAZARD (152 1XI M.) / `\ / AA / �\ / 11 / \ (152 mm) A / ( / 1 ! / MAXIMUM FROM JJ V / FROM �a HAZARD AREA EDGE OF ! /1 n JI \ OBSTRUCTION COOKING / / \ / \ / A\ 1 \ EDGE OF COOKING HAZARD / / Al HAZARD FIGURE 77 001713 3. When an appliance requires dedicated protection with a pro- tected area intended for overlapping appliance nozzle protec- tion,the group protection option will be required for appliances on either side of the appliances using dedicated protection. Group protection using overlapping appliance nozzles must FULL HOOD CONTINUOUS APPLIANCE PROTECTION begin with the protected appliance(s)adjacent to the dedicat- ► FIGURE 75 ed appliance protected. An overlapping appliance nozzle(s) a must be positioned within 6 In.(152 mm)of the edge(s)of the appliance hazard surface area(s) adjacent to the dedicated ► nozzle protection.See Figure 78. 12 IN.(305 mm) 6 IN.(152 mm) MAXIMUM MAXIMUM EDGE OF COOKING I� ,I� I; .IL I� F1 HAZARD 61N. —► t� 01. - 1-4- 7N---►1 6 1N. 1 _�/ (152 mm) 12 IN. (152 mm) 61N, 1 1 121N. 1 t 12 IN. 12 IN. MAXIMUh1 (905 mm) h1AXIMUh1 (152 mm I(96 � I(905 mm)(305 mm) 6 IN. FROM ! �/ MAXIMUM MAX. I1 MAX. `4 MAX MAX. (152 mm) EDGE OF \ / EDGEE OF OF i OKING COOKING MAX.h( EDGE_i 6 IN.(152 mm) 6 IN.(152 mm)HAZARD EDGE OF HAZARD OF EDGE MAXIMUh1 COOKING ��� MAXIMUM OF HAZARD COOKING HAZARD COOKING HAZARD GROUP APPLIANCE PROTECTION ► FIGURE 76 00,7:0 DEDICATED NOZZLE APPLIANCE ► FIGURE 78 001756 SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-43 4-1-06 REV.5 TANK AND CARTRIDGE REQUIREMENTS ACTUATION AND EXPELLANT GAS LINE REQUIREMENTS Once the hazard analysis is completed and the total nozzle flow This section contains the guidelines for installing the actuation and numbers are established,the quantity and size of agent tanks and expellant gas lines between the regulated release mechanism reg- cartridges needed to supply the nozzles with the proper volumes ulator, each regulated actuator regulator, and each agent tank. of agent at the proper flaw rates can be determined.For cartridges These limitations should be considered when selecting the com- used in the regulated release mechanism, flow capacities, tank ponent mounting locations. quantities and sizes, and regulated release cartridge options are given in the table below. Actuation Gas Line—6 to 8'Tanks Maximum Total Quantity and Regulated Release '8 Tank maximum reflects the utilization of 3 tank regulated actuators. Flow Size of Cartridge Options 1.Use only 114 in. Schedule 40 black iron, hot-dipped galva- ' s' Tank(s) Nitrogen Carbon Dioxide nized,chrome-plated,or stainless steel pipe and fittings. 1 — 5 (1) 1.5 Gallon LT20-R 101-10 2.The actuation gas line piping is installed from the regulated 6—11 (1)3.0 Gallon LT30-R 101-20 release mechanism to each regulated actuator connected within the system.The total length of the actuation gas line 11 —16 (1) 1.5 Gallon Double 101-30 from the regulated release assembly to the regulated actuator (1)3.0 Gallon assembly(ies) must not exceed 20 ft.(6 m) when using an 16—22 (2)3.0 Gallon Double 101-301, LT 20-R, an LT 30-R nitrogen cartridge, or a 101.10 or a When one or more regulated actuators are used, the following 10 1-20 carbon dioxide cartridge.See Figure 80. tank and cartridge combinations apply for each regulated actuator: Regulated Actuator Regulated Actuator Tank(s) Cartridge (1) 1.5 Gallon LT20-R or 101.10 (1)3.0 Gallon LT30-R or 101-20 (1) 1.5 Gallon and LT-A-101-30 or 101-30"or (1)3.0 Gallon double tank (2)3.0 Gallon LTA-101-30 or 101-30"or double tank ' For exceptions to maximum Ilrnv numbers.see Distribution Piping Requirements for 1.5 gallon and 3.0 gallon systems In this Section. The 101-30 cartridge cannot be used when(2)two 3.0 gallon tanks are manifaided together.) For higher total flow numbers(23 to 110), multiple cartridges and regulated actuators are required as shown in the System Selection Guide in Section IX—Appendix. REGULATED ACTUATOR ASSEMBLY EXPELLANT GAS UNES NOT INCLUDED IN ACTUATION GAS LINE LENGTH TOTALS REGULATED ACTUATOR ASSEMBLY ACTUATION GAS LINE WITH AN LT-20•R, LT-30•8,101-10 OR 101 QO CARTRIDGE MAXIMUM LENGTH OF 20 FT,(6 m). MAXIMUM NO.OF FITTINGS 9 REGULATED ACTUATOR ASSEMBLY 'ANSUL AUTOMAN' REGULATED RELEASE ASSEMBLY FIGURE 80 SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4.45 4-1-06 REV.3 ACTUATION AND EXPELLENT GAS LINE REQUIREMENTS (Continued) 2.A combined total of nine fittings may be used in these lines, Expellant Gas Line eight 90°elbows and one tee.Two 45, elbows equal one 901 1.The expellant gas line piping is installed from the regulated elbow. release mechanism in double and multiple-tank systems,and 3. If two tanks are connected to the regulated release assembly from the regulated actuator assembly in multiple-tank sys- in a multiple-tank system arrangement, the total combined tems.The expellant gas line is the piping between the regula- length of the actuation and expellant gas lines must not for and the tank-enclosure/tank-bracket assembly. The total exceed 30 ft.(9 m) when using a"double-tank"nitrogen car- length of the expellant gas line from the regulated release tridge, an LT-A-101-30 nitrogen cartridge, or a 101-30 carbon mechanism or each regulated actuator assembly must not dioxide cartridge.See Figure 81. exceed 30 it.(9 m) when using a"double-tank"cartridge, an ► LTA-101-30 Cartridge,or a 101-30 Cartridge.See Figures 83 DISTRIBUTION PIPING REQUIREMENTS ' and 84. Once the nozzle placement and quantity of tanks has been deter- mined, it is then necessary to determine the piping configurations EXPELLANT GAS LINE between the tank adaptor and each discharge nozzle.This section MAXIMUM LEPIGTN-30 FT.(99 Contains the guidelines and limitations for designing the distribu- tion piping so that the liquid agent will discharge from the nozzles at a proper flow rate.These limitations should also be referred to when selecting the mounting location for the regulated release mechanism and agent tank. General Piping Requirements 1.All R-102 system piping is straight line.Therefore,the need for critical lengths and balancing is minimized. 2 Two 45'elbows count as one 90'elbow. 3.Each branch line includes the tee or elbow leading to it, and 'ANSUL AUTOhLAN" all fittings within the branch'line itself. REGULATED RELEASE 4.The minimum piping length of Schedule 40,3/8 in.pipe from ASSEMBLY the tank outlet to any nozzle protecting a range, fryer,or wok must be 6 ft.(1.8 m). 5.Pipe lengths are measured from center of fitting to center of ► FIGURE 83 fitting.See Figure 85. MO CENTER TO CENTER EXPELLANT GAS LINE MAXIMUM LENGTH-30 FL(9 ml. MAXIMUM NO,OF FITTINGS-9 1+ ' FIGURE 85 MGM 6.All distribution piping must be 3/8 in.Schedule 40 black iron, chrome-plated,or stainless steel.Do not use hot dipped gal- vanized pipe on the distribution piping. 7. All threaded connections located in and above the protected area must be sealed with pipe tape.Tape should be applied to male threads only.Make certain tape does not extend over the end of the thread,as this could cause possible blockage of the agent distribution. 8. Before installing blow-off caps on nozzles, apply a small amount of Dow Corning No. 111 silicone grease across the opeing in the nozzle tip and also a small amount coating the REGULATED ACTUATOR exterior of the blow-off cap.This will help keep cooking grease ASSEMBLY P• P P 9 FIGURE 84 from building up on the cap. ' . 9. Tees used in the distribution piping can be used as thru tees, ► side outlet tees,or bull tees. SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4.47 4-1-06 REV.4 DISTRIBUTION PIPING REQUIREMENTS(Continued) Supply and Branch Line Identification(Continued) PLENUM BRANCH LINE NOTICE The Plenum Branch Line is defined as the length of pipe which Branch lines cannot start ahead of a supply line runs from the supply line to the plenum nozzle(s).This includes all tee. branch line fittings as well as the tee or elbow used to start the DUCT BRANCH LINE ►branch line.See Figures 86 and 89. The Duct Branch Line is defined as the length of pipe which runs --� from the supply line to the duct nozzle(s).This includes all branch line fittings as well as the tee or elbow used to start the branch line. ►See Figures 87 and 88. -•* I PLENUM BRANCH LINE 1 (TEE INCLUDED) \rl DUCT BRANCH LUTE I (ELBOW INCLUDED) PLENUM BRANCH LINE •^,•- (TEE INCLUDED) Q DUCT BRANCH LINE (TEE INCLUDED) -� FIGURE 89 DUCT BRANCH LINE cama> j,.-- (TEES INCLUDED) APPLIANCE BRANCH LINE 4 The Appliance Branch Line is defined as the length of pipe which runs from the supply line to the appliance nozzle(s).This includes ,y•" all branch line fittings as well as the tee or elbow used to start the f• 'branch line.See Figures 87 and 90. ) i I i 1 I I APPLIANCE BRANCH UNES ► FIGURE 88 (TEES INCLUDED) oaaiei ► FIGURE 90 SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-49 4-1-06 REV.4 DISTRIBUTION PIPING REQUIREMENTS(Continued) Distribution Piping Requirements—3.0 Gallon System 1. The maximum length between the start of the first branch line SUPPLY and the start of the last branch line must not exceed 24 ft. ' TEE (7.3 m).When the supply line is split, the combined total of both legs of the supply line (from the start of the first branch line to the start of the last branch line) must not exceed 24 ft. ^' (7.3 m),See Figure 93, U omz�a 2. The total length of all branch lines must not exceed 36 ft. COMBINED LENGTH OF BOTH LEGS OF SUPPL'y (10.9 m).See Figure 93. LINE MUST NOT 3 BRANCH LINES 3. Use a 318 in.union to connect the tank adaptor to the 3/8 in. EXCEED 24 FT.(7.3 m) supply line. 4. A maximum of two nozzles are allowed per duct branch line. 5. The requirements of the following table must not be exceeded: 2W NOZZLE IN NOZZLE a—I N NOZZLE t� O 220 NOZZLE -- (BRANCH LINE IN BOLD) 1 245 AIOZZLE 12N NOZZLE COMBINED LENGTH MUST 000502 NOT EXCEED 36 FT.(10.9 m) FIGURE 93 Duct Plenum Appliance Reauirem nts Supply Line Branch Line Bomah Lin-e Branch Line Pipe Size 3,18 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 8 ft. 4 ft. 12 ft. (12.2 m) (2.4 m) (1.2 m) (3.7 m) Maximum Rise 6 ft. 4 ft. 2 ft. 2 ft. (1.8 m) (1.2 m) (.6 m) (.6 m) Maximum 90' 9 4 4 6 Elbows Maximum Tees 1 2 2 4 Maximum Flow 11' 4 2 4 Numbers � 'ExcepOons: 1. Twelve(12)flow numbers are allowed in any one lank for duct and plenum protection only. 2.Twelve(12)flow numbers are alloyed with any one tank using only twallow appliance nozzles 3.Twelve(12)flow mimbors are allowed with any one tank using only ti ree-flow appliance nozzles. Special Instructions: 1.Twelve(12)How numbers are allowed when four(4)Dean Industries GTI Gas Fryers are protected at low proximity as shown In Figure 56 on Page 4.32 The discharge piping must be as shown In Figure 59 on Page-1-32. 2. For certain McDonald's appilcalions,I f.5 flow numbers are allowod when using a cftbina60n of one it)2W duct nozzle,one(I)112N electrostatic precipitator nozzle, one(1)1N plenum nozzle,and four(4)two-flow appllnnc0 nozzles.Contact Ansul Applications Engineering Department for additional informalicn. SECTION IV — SYSTEM DESIGN UL E<..3470 ULC CEx747 Page 4.51 4-1-06 REV.4 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements—6.0 Gallon Ailanifolded Distribution Piping Requirements—6.0 Gallon System with System(Continued) Independent Pipe Runs This configuration consists of hvo 3 gallon tanks. Both tanks are Independent pipe runs can also be used with the regulated connected to a common manifold tee and are pressurized from a ►release assembly and the tank/enclosure assembly. See Figure single double tank(Part No.73022)nitrogen cartridge in the regu- 96. When manifolding is not used, each of the two (2) 3 gallon ►lated release assembly. See Figure 95. Note:A tank mounting tanks utilize the piping limitations of a single tank system. bracket can be utilized instead of the tank/enclosure assembly. 'See Figure 97. 3/8 IN, BRANCH its IN. 3/8IN. SUPPLY SUPPLY SEE USE HOSE/ NOTE HOSE/ ► GROMMET NO.I �4L GROM E GROMMET d—3/8 IN BRANCH PACKAGE (PART NO. 3t6 IM• I SEE SUPPLY (PART NO. NOTE ! -018511) 418511) ► I NO.1El 11 i i I 9 3.0 3.0 3 0 GALLON TPGALLONGALLON GALLON TANK TANK TANK OR DOUBLE TANK 1.5 GALLON DOUBLE TANK NITROGEN TANK NITROGEN CARTRIDGE OR CARTRIDGE OR (LT-A-101-30 I 10 1-30 CO2 CARTRIDGE— CARTRIDGE 3.0 GALLON REGULATED RELEASE REGULATED CARTRIDGE REGULATED RELEASE'ASSEMBLY OR C ASSEMBLY OR 3.0 GALLON REGULATEDACTUATOR ONC/) REGULATED ACTUATOR ASSEMBLY CARTRIDGE— — REGULATED ACTUATOR ASSEMBU( TANK/ENCLOSURE ACTUATOR ONLY) ► ASSEMBLY T1NK'ENCLOSURE FIGURE 96 ASSEMBLY NOTE 1: THE PIPE CONNECTION FROM TANK CENTER TO TANK CENTER CANNOT EXCEED 8.1/2 IN.(21.5 cm).ALSO,OEM RELEASE/BRACKET ASSEMBCr CAN BE UTILIZED WHEN NIANIFOLDING 3.0 GALLON TANK. NOTE 2:ONLY 3 GALLON TANKS CAN BE NIANIFOLDED. ► FIGURE 95 WOO SECTION IV - SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-53 4-1-06 REV.3 DETECTION SYSTEM REQUIREMENTS Once the fire suppression system design has been determined,,a Detector Placement Requirements detection system design must be completed.This section contains EXHAUST DUCTS guidelines and limitations for detection system installation. Each exhaust duct must have at least one detector installed in the Detector Identification duct entrance,located in the airstream of the cooking vapors,or at' The trio types of detectors are distinguished from each other by 'a maximum of 20 ft.(6.1 m)into the duct opening.See Figure 98. their location in the detection system. 1.The Terminal Detector(Part No.56838, 15375, or 417368) is the last in a series of detectors, or the only detector used in a single-detector system.This detector is thus named because it is at the point at which the wire rope ends,or"terminates:' 2.A Series Detector(Part No.56837, 15373, or 417369) is any detector located in-line between the regulated release mech- anism and the terminal detector. 20 FT.(6 m) Detector/Pulley Elbow Quantity MAXIMUM The quantity of detectors used in the system will vary depending on the style of detector used. 1.Conduit runs,pulley elbows,and number of detectors per sys- tem must be within the approved system guidelines.The fol- lowing requirements must not be exceeded: Maximum Maximum Maximum Number of Number of Length of 1/2 . FIGURE 98 Detectors Elbows in.Conduit per System p_Qr3ystem per 5vS a0271 NOTICE - Clip on Style 12 18 125 ft.(38.1 m) When gas appliances are used and the flue Detector gases from the burner are exhausted into the Hinge Style 5 8 103 ft.(31.3 m) duct, the detector must be kept out of the air Detector stream of these exhaust gases. These gases can be very hot and could actuate the system Scissors Style 15 20 150 ft.(45.7 m) unnecessarily. Detector Duct openings that are long and narrow or large 2.If hinge style detectors are mixed in a system with either clip- enough to require multiple duct nozzles may on or scissor style, 4 series and 1 terminal is the maximum require additional detectors. number allowed. If clip-on style are mixed with scissor style, ELECTROSTATIC PRECIPITATOR the maximum allowed is 11 series and 1 terminal. NOTICE If an electrostatic precipitator is located at or near the base of the When using the"clip-on"style detector, the ter- exhaust duct, it is necessary to locate a detector below the pre- minal detector may use the "hinged" style cipitator, at the base of the duct, and also locate one In the duct, mounting bracket with the"clip-on"style linkage. 'just above the precipitator.See Figure 99, This is only allowed with the terminal detector. When installing the detector bracket and system conduit, make No other linkages are allowed to be mixed certain they do not interfere with the operation of the precipitator. with other brackets. When using this option, Note: On secondary filtration units utilizing multiple filter the total number of'clip-on"style detectors (11 stages/media,contact Ansul Technical Services for instructions. series and 1 terminal)Is still allowed. 3.If hinge style detectors are mixed in a system with either clip- on or scissor style,the maximum length of wire rope must not exceed 103 ft. (31.4 m) and the maximum number of pulley elbows must not exceed 8.If clip-on style are mixed with scis- sor style, the maximum length of wire rope must not exceed 125 ft. (3.81 m) and the maximum number of pulley elbows must not exceed 18. 4.If the hazard requires more than 15 detectors, up to five 101 Remote Releases (Part No. 32381) can be used for system actuation.Each 101 remote release allows the use of a maxi- mum of 15"scissor"style detectors(14 series and 1 terminal) for a total of 75 detectors if needed. FIGURE 99 O e-= SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4.55 4-1-06 REV.3 MANUAL PULL STATION REQUIREMENTS Metal Stamped Style—Part No.4835 or 54011 A remote manual pull station allows the R-102 system to be man- Parts that may be used for installation of a metal stamped remote ually operated at some point distant from the regulated release manual pull station are: ►assembly.The pull station should be installed at a height of 42-48 Description Part No in. (107-122 cm), in accordance with the requirements of the Remote Manual Pull Station Assembly' 54011 American Disabilities Act(ADA)and the Authority having Jurisdic- Remote Manual Pull Station Assembly 4835 .tion.and located in the path of egress.The pull station Is the only Pulley Elbow 423250 source of manual actuation of the regulated release assembly. Pulley Elbow 415670 The total length of the cable used for each manual pull station with- Pulley Tee 427929 in a system must not exceed 150 ft.(46 m). 'Assembly includes Pans listed baiav The maximum number of pulley elbows that may be used per pull 1/16 in.Stainless Steel Cable 50 ft.(15 m) 15821 station is 20. Oval Press-To-Crimp Sleeves 4596 One pulley tee, Part No,427929, is allowed per system. Glass Break Rod(1) 4834 The maximum length of cable from the AUTOMAN to a pull station MECHANICAL GAS VALVE REQUIREMENTS is 150 ft.(45.7 m)with a maximum of 20 pulley elbows used per An ANSUL or ANSUL approved mechanical gas shut-off valve side of the tee.As the tee is located farther from the AUTOMAN, system can be attached to the R-102 system.The system works the 150 ft. (45.7 m) maximum must be observed but as pulley both mechanically and pneumatically by use of an air cylinder elbows are placed between the AUTOMAN and the tee,they must located inside the regulated release assembly.Upon actuation of be deducted from the available pulley elbows(20)allowed on each the fire suppression system,a pneumatically-operated air cylinder side. assembly will mechanically close the gas shut-off valve. Example:If 10 pulley elbows are placed between the AUTOMAN The total length of the cable for each mechanical gas valve must and the pulley tee, the maximum available pulley elbows left for not exceed 150 ft.(46 m).The maximum number of pulley elbows ►use on each side of the tee is 10 per side.See Figure 103 for three that may be used is 20 for each valve. different examples. (Note: Both must be gas valves or both must One pulley tee(Part No.427929)is allowed per system. be pull stations.Mixing is not allowed.) The maximum length of cable from the AUTOMAN to a gas valve is TEE CLOSE TO AUTOMAN(EXAMPLE) 150 ft.(45.7 m)with a maximum of 20 pulley elbows used per side PULLEY TEE of the tee. As the tee is located farther from the AUTONIAN, the 150ft.(45.7 m)maximum must be observed but as pulley elbows are (I IM mm) placed between the AUTOMAN and the tee,they must be deducted from the available pulley elbows(20)allowed on each side. Example: If 10 pulley elbows are placed between the AUTOMAN and the pulley tee, the maximum available pulley elbows left for AUTOMAN use on each side of the tee is 10 per side.See Figure 103 for three MANUAL PULLLL MANUAL PULL GAS VALVE GAS VALVE OR ► P different examples. 149 FT.(45.4 m)AND 20 PULLEY ELBOWS MAXIMUM Parts that may be used for installation of a Mechanical Gas Shut- PER EACH SIDE OF TEE off Valve are: TEE CLOSE TO GAS VALVES OR MANUAL PULL(EXAMPLE) D-escription Part No. Gas Valve/Actuator 3/4 in.Assembly(ANSUL)' 55598 1tPULLEYTAEE . Gas Valve/Actuator 1 in.Assembly(ANSUL)' 55601 ( m) mm) Gas Valve/Actuator 1 114 in.Assembly(ANSUL)' 55604 Gas Valve/Actuator 1 1/2 in.Assembly(ANSUL)' 55607 GAS VALUE OR GAS VALVE On Gas Valve/Actuator 2 in.Assembly(ANSUL)' 55610 MANUAL PULL MANUAL PULL Gas Valve/Actuator 2 1/2 in.Assembly(ASCO)` 25937 AUTOMAN Gas Valve/Actuator 3 in.Assembly(ASCO)' 25938 149 FT.(45A m)AND 20 PULLEY ELBOWS BETWEEN Pulley Elbow 423250 AUTOKIAN AND TEE Pulley Elbow 415670 Pulley Tee 427929 TEE HALFWAY BETWEEN AUTOMAN AND GAS VALVES OR MANUAL PULL(EXAMPLE) 1/16 in.Stainless Steel Cable 15821 or 75 FE(22.9 m)AND 10 PULLEY ELBOWS 50 ft.(15 m)or 500 ft.(152 m) roll 79653 Oval Press-To-Crimp Sleeve 4596 Stop Sleeve(2) 26317 75 FL(22.9 m)AND 75 FT.(22.9 m)AND 'Assembly includes parts bled belay: 10 PULLEY ELBOWS 10 PULLEY ELBOWS Air Cylinder Assembly 15733 6- PULLEY TEE Air Cylinder 15521 Tubing Assembly 15529 AUTOMAN GAS VALVE OR GAS VALVE OR Copper Tubing, 1/8 in. 15525 MANUAL PULL MANUAL PULL Male Elbow 15523 ' FIGURE 103 Male Connector 15522 Machine Screw(2) 15421 Hex Nut(2) 15527 Lockwasher(2) 4141 Visual Inspection Seal(2) 197 SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-57 4-1.06 REV. 1 ELECTRICAL SWITCH REQUIREMENTS(Continued) Electric(110 VAC/60 Hz)Gas Shut-off Valve INSTALLATION OVERVIEW POWER SOURCE O _MANUAL RESET O RELA'f ELECTRIC SNAP-ACTION SWITCH ELECTRIC GAS VALVE JUNCTION BOXES (NOT SUPPLIED BY ANSUL) xa�ri WIRING SCHEMATIC WIRING SCHEMATIC—RELAY PART NO.426151 ——— BLACK ANSULSNAP•ACnON SWITCH RED (SWITCH CONTACTS SHOWN WITH ANSUL AUTOMAN IN THE COCKED POSITION) BROWN 1 RESET POWER 1 INDICATOR GNO I A B SCRewI 5 1 L2NEUTRAL 1 RELAY COI 4 L1 HOT 110 VAC/60HZ I L I I I 6 13 1 9 I I 3 12 1 4 1 1 7 i1 1 i I MANUAL RESET RELAY I ' I (PART NO.426151) I I I i 1 ELECTRIC RATING W HP,10 Amp,120 VAC GAS VALVE 1/2 HP,10 Amp,240 VAC SEE NOTE 3 ao.asz NOTE: 13 Amp,28 VDC I. DENOTES FIELD INSTALLATION, 2. _____DENOTES FACTORY INSTALLATION. FIGURE 104 3 CONTRACTORS:'UL LISTED ENCLOSED INDUSTRIAL CONTROL EQUIPMENT OR MAGNETIC SWITCH HAVING A RATING MATCHING THAT OF THE COOKING APPLIANCE COIL,110VA30HZ.' 4 DO NOT USE BLACK WIRE ON SNAP-ACTION SWITCH IN D;ORMAL INSTALLATION.BLACK WIRE TO BE USED ONLY FOR EXTRANEOUS ALARM,LIGHT CIRCUITS.ETC. SECTION IV — SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-59 4-1.06 REV. 1 _ ELECTRICAL SWITCH REQUIREMENTS (Continued) Electric(110 VAC/60 Hz) Application with Customer Supplied Contactor and Heating Element Load,and Power Supply Switch INSTALLATION OVERVIEW POWER SOURCE -� MANUAL RESET 0 RELAY ELECTRIC SNAP-ACTION SWITCH OR SWITCH THERMOSTAT (CUSTOMER SUPPLIED) e 1 JUNCTION BOX (RIOT SUPPLED B'(ANSUL) CONTACTOR (CUSTOMER SUPPLIED) maw MIRING SCHEMATIC WIRING SCHEMATIC—RELAY PART NO.426151 r-- BLACK RED ANSUL SNAP-ACTION SWITCH BROWN (SWITCH CONTACTS SHOWN WITH ANSUL __- AUTOMAN IN THE COCKED POSITION) r-------------------- RESET POWER i INDICATOR I GNDI nREOr A B SCRVAI 5 L2 NEUTRAL RELAY COIL - I.1 LI HOT 110 VAG60HZ I 6 1c I 3 12 I 4 +— I CONTACTOR SWITCH OR THERMOST (CUSTOMER SUPPLIED) MANUAL RESET RELAY I (CUSTOMER SUPPLIEDTA)r -- (PART NO.426151) --_-----J --J ! 1 I ELECTRIC RATING I 1,3 HP,10 Amp,120 VAC 12 HP.10 Amp,240 VAC TO HEATING 13 Amp.28 VDC TO PONlER SUPPLY ELEMENT LOAD 220Vl440V NOTE: wnmi ,I 1. --DENOTES FIELD INSTALLATION. 2. _DENOTES FACTORY INSTALLATION. 3. CONTRACTORS:'UL LISTED ENCLOSED INDUSTRIAL CONTROL EQUIPMENT OR MAGNETIC SWITCH HAVING A RATING MATCHING THAT OF THE COOKING APPLIANCE COIL,1 I0V,'60HV 4 DO NOT USE BLACK WIRE ON SNAP-ACTION SWITCH IN MORMA),INSTALLATION BLACK WIRE TO BE USED ONLY FIGURE 106 FOR EXTRANEOUS ALARM,LIGHT CIRCUITS.ETC SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5-1 4-1-06 REV.6 _ INSTALLATION INSTRUCTIONS t The Installation information listed in this section deals with the lim- If not already done, mount both boxes to a rigid surface itations and parameters of this pre-engineered system.Those indi- using appropriate fasteners. viduals responsible for the installation of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 train- Fill tanks per instructions listed in Steps 3 and 4 on ing program. Page 5 3. Before attempting any installation, the entire system design must Next,route hose through grommets and wrench tighten into have been determined including: Nozzle Placement, Tank 114 in.inlet of the adaptor on the tank in the tank/enclosure Quantity,Actuation and Expellant Gas Piping, Distribution Piping, assembly. Also install hose to tank adaptor in regulated and Detection System Requirements and an installation sketch release and wrench tighten. See Figure 96 in "Design should be completed. Section"for details of hose routing. MOUNTING THE COMPONENTS REGULATED RELEASE ASSEMBLY For successful system performance,the regulated release assem- ��16 1/2 IN. bly, regulated actuator assembly(ies), and tank-enclosures) or (42 cm) tank-bracket assembly(ies) used must be located in areas where 13 131I61N, the air temperature will not fall below 32 °F (0 °C) or exceed (35 cm) •130°F(54°C).The R-102 system is limited to interior applications / 0 1 M IN. ►only. Also, the components must be arranged to conform to the /' a (3.5 cm) O Q actuation and expellant gas line,and the distribution piping guide- lines noted in"System Design." 1, CAUTION ® 23 12 IN. Use only an ANSUL AUTOMAN Regulated Release (597 cm) Q ( assembly or OEM Release/Bracket Assembly.The regu- 19 71161N. lator in this assembly is specifically designed to allow a O ( (49.3 cm) regulated flow of expellant gas into the agent tank(s). Absence of this regulator could cause the tank(s) to rup- ture or create an improper system discharge. Mount the regulated release assembly, OEM Release / Assembly,and each regulated actuator assembly required by O ` 7 112 IN (19 cm) completing the following steps:See Figures 1,2, and 3. a. Select a rigid surface for mounting the enclosure, The FIGURE 1 mounting locations must allow the regulated release ,�j, assembly and the regulated actuator assembly(ies) to be within the limitation of the actuation and expellant gas line REGULATED ACTUATOR ASSEMBLY lengths and must be able to support the weight of the assembly(fes). When the OEM Release Assembly is ,61rz,r,. mounted inside a cabinet,clearances shall be provided for (42 cm) unrestricted movement of the release assembly compo- nents within the closed cabinet. 13 13/16 I"• (35 cm) b. Detach cover from the enclosure.Remove agent tank from , 0 1 316 IN. enclosure and the expellant gas line hose from the a e (3.5 cm) tankladaptor assembly. c. Secure enclosure box to selected mounting location using \} the four mounting holes.Use appropriate type of fasteners depending on the mounting surface. Q 23 112 IN, d. When mounting a 6-gallon manifolded system (or a 6-gal- (59.7 cm) Ion individual t system) s critical each mounting piped y )It i itil that h g O I � 19 7l16 IN.I box is located as shown in Figure 3a.There must be a 5/16 in.space between each box.Less than 5/16 in.will cause �- interference with the covers, and more than a 5/16 in.will / cause a gap between the two hose grommets which will expose the hose to possible tampering or damage. Remove the 7/8 in.knockout in the left side of the ANSUL ,2 IN AUTOMAN release box and remove the 1 in. knockout in 7 7 Ir2I the right side of the tank-enclosure box.Install grommets in /' each (use ANSUL hose/grommet package, Part No. FIGURE 2 418511).Remove 1/4 in.plug from back side of R-102 reg- ular and install fixed end of secondary expellant gas hose (included in hose/grommet package, Part No. 418511) in 1/4 in.regulator outlet and wrench tighten. SECTION V - INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5-2.1 4-1-06 REV.5 MOUNTING THE COMPONENTS(Continued) 3. Fill each agent tank by completing the following steps: ' STAINLESS STEEL TANKS a. Remove tank adaptor/tube assembly from tank fill opening, FROM rTHE TOPJOFTHE COLLAR Visually inspect tank adaptor to determine bursting disc is in -_-�--- FOR THE 3.0 GALLON TANK place and that silver side is away from tank.See Figure 5. — OR 1 3/'1 IN,t UB IN.(45 mm t 3 mm)) FROM THE TOP OF THE COLLAR FOR THE 1.5 GALLON TANK 000292 RED PAINTED STEEL TANK 1 IN.TO 1 118 IN.(25-29 mm) FROM THE BOTTOM OFTHE FILL OPENING FOR BOTH 3.0 GALLON AND FIGURE 5 1 5 GALLON TANKS O J'241 b. Safety glasses should be worn during transfer opera- tions of ANSULEX Low pH Liquid Fire Suppressanl. Avoid contact with skin or eyes.In case of contact,flush immediately with water for 15 minutes. If irritation per- CIA292� sists,contact a physician.Do not take internally.If taken FIGURE 6 internally do not induce vomiting. Dilute with water or milk and contact a physician immediately. c. Reinstall adaptor/tube assembly to tank by tightening until metal to metal contact is achieved between bottom of adap- Place plastic funnel in fill opening and fill tank with 1,5 for and tank collar. (5.8 L) or 3.0 (11.6 L) gallons of only ANSULEX Low pH 4. Place each tank into its enclosure or bracket. Liquid Fire SuppressanL See Figure 6 for detailed filling tol- erances.Note:Use a funnel with a screen to stop any for- eign material from entering the tank.See Figure 6. CAUTION During filling,the agent temperature should be 60 IF to 80 IF (16 'C to 27 °C). DO NOT FILL WITH COLD AGENT. DO NOT OVERFILL. Overfilling may result in agent entering gas hoses and regulator potentially causing system malfunction. i SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5-3 7-1-98 REV.2 INSTALLING THE ACTUATION AND EXPELLANT GAS LINE NOTICE Before installing any actuation or expellant gas line, the piping Do not allow tape to overlap the pipe open- design must be determined;and the regulated release assembly, ing, as this could cause passible blockage of each regulated actuator assembly and each tank-bracket assem- the gas pressure. bly should be securely mounted. Thread sealant or compound must not be General Piping Requirements used. 4.When connecting actuation or expellant gas line piping, install 1.Use only 114 in. Schedule 40 black iron, hot-dipped galva- a 1/4 in.union near the tank inlet for easy disassembly later, nized, chrome-plated,or stainless steel pipe and fittings. 2.Before assembling the pipe and fittings, make certain all ends Actuation Gas Line are carefully reamed and blown clear of chips and scale. Install actuation gas line from the regulated release mechanism Inside of pipe and fittings must be free of oil and dirt. high pressure side outlet(side opposite regulated outlet) through 3.The piping and fitting connections must be sealed with pipe the appropriate knockout in the enclosure by completing the fol- tape. When applying pipe tape, start at the second male lowing steps: thread and wrap the tape (hao turns maximum) clockwise 1.Remove the 1/8 in.plug from high pressure side outlet.Install around the threads, away from the pipe opening. the appropriate fitting for additional equipment attachment as required.A 1/4 x 1/8 in.reducing fitting is required to connect the 1/4 in.actuation line.See Figure 7. Typical Arrangements For A One Device Connection To Cartridge Receiver 1 more Typical Arrangements For A Two Device Connection To Cartridge Receiver 8 8 g 000� Typical Arrangements For A Three Device Connection To Cartridge Receiver 6 8 lip 000^35 TO REGULATED ACTUATOR TO TANK W (MULTIPLE TANKS ONLY) BRACKET OR TO TANK IN BRACKET TO REGULATED PIPE(OR HOSE WHEN BRACKET /OR ENCLOSURE ACTUATOR TO ENCLOSURE ONLY) r (MULTIPLE TANKS ONLY) TO PRESSURE 2 IN.NIPPLE SWITCH REQUIRED OVANKIN TO TANK IN REGULATED TO TANK IN REGULATED TO TAB JK IN REGULATED REGULATED RELEASE ASSEMBLY RELEASE ASSEMBLY RELEASE ASSEMBLY RELEASE ASSEMBLY SINGLE TANK DOUBLE AND-MULTIPLE TANKS SINGLE LANK WITH DOUBLE AND MULTIPLE PRESSURE SNATCH TANKS WITH PRESSURE -- CONNECTION SWITCH CONNECTION NOTE: ALL PIPE AND FITTINGS SHALL BE SCHEDULE•10(STANDARD WEIGHT)BLACK IRON,HOGTIPPED GALVANIZED,CHROME-PLATED.OR STAINLESS STEEL. FIGURE 7 SECTION V - INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5-5 10-1-02 REV.4 INSTALLING THE ACTUATION AND EXPELLENT GAS LINE (Continued) 4, If an actuation gas line is connected to the regulated release Expellant Gas Line From The Regulated Release Assembly assembly along with an expellant gas line,the total combined Install expellant gas line frorn the regulated release assembly reg- length of the gas lines must not exceed 30 ft. (9 m) when ulator in the enclosure by completing the following steps: using a"double-tank"nitrogen cartridge or a 101.30 CO2 car- ' 1. The regulated release assembly is shipped with afactory- tridge.See Figure 9. installed regulator.The regulator has two 1/4 in.outlets,one at 5. A combined total of nine fittings may be used in these lines, the back and one at the bottom.The bottom outlet connects eight 90' elbows and one tee.Two 451 elbows equal one 90' the expellant gas hose to the agent tank which is mounted elbow. inside the enclosure.The back outlet is sealed with a 1/4 in. Expellant Gas Line From The Regulated Actuator Assembly plug. 2. Connect expellant gas hose to the agent tank mounted inside Install expellant gas piping from the regulated actuator assembly the enclosure. If a pressure switch is required, a 1/4 in.x 1/8 regulator through the appropriate knockout in the enclosure by completing the following steps: in.reducing fitting will be required for connection between the back regulator outlet and the pressure switch.See Figure 7. 1. The regulated actuator is shipped with a factory-installed reg- ulator.The regulator has two 1/4 in. outlets 135' from each DOUBLE AND MULTIPLE TANK SYSTEMS: other.One outlet Is sealed by a 1/4 in.plug and the other con- If the expellant gas piping is required because an additional tains the expellant gas hose for the agent tank which will be tank-enclosure or tank-bracket assembly is being installed,the mounted within the enclosure.Connect expellant gas hose to plug installed in the back outlet must be removed.(See Figure the agent tank that is mounted inside the enclosure. 6 for proper connections to the regulator,) 2. Remove the 114 in.pipe plug from the regulator side outlet and 3. Pipe the 1/4 in,expellant gas line from the regulator back out- pipe the 1/4 In. expellant gas line from the regulator through let through one of the knockouts provided in the enclosure. the knockout provided in the enclosure to a tank-enclosure or tank-bracket assembly.A maximum of one tank-enclosure or The total length of the expellant gas line from the regulated tank-bracket assembly is allowed per regulated actuator release assembly must not exceed 30 ft,(9 m)when using a assembly. "double-tank" nitrogen cartridge or a 101-30 CO2 cartridge. The maximum length of the expellant gas line from the re u- See Figure 10. lated actuator to the tank-bracket assembly must not exceed 30 ft.(9 m).See Figure 11. EXPELLANT GAS LINE 3. A total of nine fittings may be used in these lines, eight 90° - MAXIMUM LENGTH—90 FT.(9 m). elbows and one tee.Two 45'elbows equal one 90°elbow. MAXIMUM NO.OF Fn71NGS—9 EXPELLANT GAS LINE MAXIMUM LENGTH—90 FTTTI (9 mJ, MAXIMUM NO.OF FITTINGS—9 REGULATED RELEASE ASSEMBLY FIGURE 10 mmna REGULATED ACTUATOR ASSEMBLY FIGURE 11 Doom SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5-7 4-1-06 REV.4 INSTALLING THE DISTRIBUTION PIPING Before the following procedures can be completed, the piping 2. Based on the piping sketch developed in the"System Design" design must already be determined;and the actuation and expel- section of this manual, install the supply line and position the lant gas lines from the regulated release,each regulated actuator, tees at points where branch lines must be installed. See and each tank-enclosure or tank-bracket assembly should already Figure 13. be installed. These installation instructions are identical for single,double, and i multiple-tank systems except for the quantity of tanks and hazard areas to be covered. r'--------- L-----------� General Piping Requirements i 1. Use Schedule 40 black iron,chrome-plated,or stainless steel L--`-----------------� pipe and fittings. NOTICE Do not use hot-dipped galvanized iron pipe or fittings in the agent distribution piping. 2. Before assembling the pipe and fittings,make certain all ends ❑ are carefully reamed and blown clear of chips and scale. Inside of pipe and fittings must be free of oil and dirt. FIGURE 13 3. The distribution piping and fitting connections, located in or 011°'02 above the hood or the protected area, must be sealed with 3. Run all branch lines to the hazard area and connect each noz- pipe tape,When applying pipe tape, start at the second male zle.(Make certain all fittings are tight and all.piping is secure- thread and wrap the tape (two turns maximum) clockwise ly bracketed.) The 1WS and 1NS nozzles can be aimed by around the threads, away from the pipe opening. slipping a 3/8 in.Schedule 40 pipe over the tip,moving the tip to the correct aiming point, and then wrench tightening the NOTICE retaining ring. Do not allow tape le overlap the pipe opening as 4. All threaded connections located in the protected area, must the pipe and nozzles could become plugged. be sealed with pipe tape. Tape should be applied to male Thread sealant or compound must not be used threads only. Make certain tape does not,extend over the end as it could plug the nozzles. of the thread, as this could cause possible blockage of the 4. Distribution piping may be run independently or two agent agent distribution. tanks may be manifolded together and run to the predeter- 5. Before installing blow-off caps on nozzles, a lI mined hazard area.Only agent tanks expelled from the same pp! a small cartridge may be manifolded. amount of Dow Corning No. 111 silicone grease across the opening in the nozzle tip and also a small amount coating the NOTICE ► exterior of the blow-off cap. DO NOT FORCE SILICONE Closely follow the piping requirements for each ► GREASE INTO NOZZLE TIP OPENING OR FILL CAP WITH size system, as detailed in the"System Design" GREASE. section,when installing distribution piping. NOTICE 5. Branchline tees can be used to create more than one branch When using a metal blow-off cap,make certain and can be installed as a thru tee,side outlet tee or bull tee. the spring clip rotates freely on the metal cap. Pipe Hanger Recommended Guidelines 6. When a nozzle utilizes a metal blow-off cap, the nozzle tip must be coated with Silicone 111 grease before the cap is 1. Space hangers as follows: installed.The grease must be wiped across the tip and around Maximum Recommended the tip so that a rim of grease will be seen once the nozzle cap Pipe Size Distance Between Hangers is in place.also,apply grease to the outside of the cap includ- 3/8 in. 5 ft.(12.7 cm) ing application of the grease between the cap clips and the cap. 2. Hangers should be placed between elbows when the distance 7. Make certain a blow off cap is in place over each nozzle ti is greater than 2 it.(0.6 m). These blow-off caps are designed to keep P P g p grease from build- Piping Installation ing-up on the nozzle orifice and inhibiting the agent flow.See Figure 14. 1. Starting at the tank,pipe directly from the union located on the tank adaptor.A reducing fitting may be necessary to conform to the distribution piping. / I i 0QU7Q'1 M=4 x10705 FIGURE 14 SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5.9 7-1-98 REV. 1 INSTALLING THE DETECTION SYSTEM (Continued) Installing"Clip-On"Style Linkage(Continued) 6.To give a constant tension on the wire rope during installation 4.From the regulated release assembly, run the stainless steel of the detector linkage, hang a vice grip or other weighted wire rope through the conduit, pulley elbows and detector device on the excess stainless steel wire rope,leaving an ade- brackets to the terminal detector. quate length of spare wire rope between the locking clamp NOTICE and the weighted device. If wire rope requires splicing, make certain NOTICE splice is at least 12 in.(30.5 cm)away from any When attaching the weighted device to the pulley elbow or conduit adaptor to avoid inter- excess wire rope, allow approximately 3 in, ference. (8 cm)of wire rope for each detector linkage for 5.Feed the wire rope through the terminal detector bracket as proper installation. shown in Figure 18 or as shown in Figure 19 if the terminal Example: If the system has six detectors, there should be detector is mounted within a duct or header opening, and approximately 18 in. (46 cm) of excess wire rope install the stop sleeve approximately 2 to 3 in.(5 to 8 cm)from between the locking clamp and the weighted the end of the wire rope. See Figure 20, Use the National device, which will be utilized when the linkage is Telephone Supply Company Nicopress Sleeve Tool(Stock No. put in place. 51-C-887)or equal to properly crimp the stop sleeve. 7.Starting at the terminal detector, place the small tab of the detector linkage onto the wire rope.See Figure 21. FIGURE 18 oav is FIGURE 21 Caa3t3 8.With the tab positioned on the wire rope, press and snap the detector linkage onto the wire rope.See Figure 22. FIGURE 19 I J� Aci I2-3 IN, '—(s-e cm1 FIGURE 22 aaan 4 FIGURE 20 OW312 I SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5-11 4-1-06 REV.2 INSTALLING THE DETECTION SYSTEM(Continued) Installing"Clip-On"Style Linkage(Continued) 17. Make certain tension' lever is in the "UP" position. See 15. With a downward motion of the cocking lever,raise cocking pin Figure 30. until the trip lever indented surface moves underneath the pin and locks the pin In the"UP"position.See Figure 28. 1 i 1 n TENSION LEVER a IN'LIP'POSITION a �. 0 8 FIGURE 30 coo,s 18. Verify each detector linkage assembly, with correct ANSUL fusible link, is in the detector bracket, located slightly toward the terminal detector side. NOTICE Due to the close adjustment between the trip FIGURE 28 hammer and cable lever assemblies, use only O.1110 the particular fusible link(s)selected for installa- 16, Remove cocking lever and insert lock bar(Part No.14985)on tion in each detector, including terminal detec- left side of the cable lever,over the two shouldered projecting tor,to ensure correct adjustment when perform- stud extensions, and slide bar forward into locking position, ing Steps 19 and 20. (The regulated release mechanism cannot be actuated, nor 19. Raise trip hammer 3/8 In, to 1/2 in. (9.5 to 12.7 mm), pull all can enclosure cover be replaced until the lock bar is slack out of wire rope, and tighten set screws on locking removed.) See Figure 29. clamp. \ m LOCK BAR PROPERC!INSTALLED FIGURE 29 SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5-13 4-1-06 REV.2 INSTALLING THE DETECTION SYSTEM (Continued) "Scissor"Style Linkage Installation (Continued) NOTICE 4.From the release assembly, run the stainless steel wire rope When attaching the weighted device to the through the conduit, pulley elbows and detector brackets to excess wire rope, allow approximately 3 in. the terminal detector. (8 cm)of wire rope for each detector linkage for NOTICE proper installation. If wire rope requires splicing, make certain splice is at least 12 in.(30.5 cm)away from any Example: If the system has six detectors, there should be pulley elbow or conduit adaptor to avoid interfer- approximately 18 in. (46 cm) of excess wire rope ence. between the locking clamp and the weighted 5.Feed the wire rope through the terminal detector bracket as device, which will be utilized when the linkage is put in place. shown in Figure 35 or as shown in Figure 36 if the terminal detector is mounted within a duct or header opening, and 7.Install detector scissor assembly as shown in Figure 38.Note install the stop sleeve approximately 2 to 3 in.(5 to 8 cm)from that the ANSUL AUTOMAN release is located on the left side the end of the wire rope. See Figure 37. Use the National of the detector bracket.Slightly crimp the two assembly"boot- Telephone Supply Company Nicopress Sleeve Too[(Stock No, hooks" over the cable with pliers so the cable is captured 51-C-887) or equal to properly crimp the stop sleeve. under each hook but the whole assembly can move from side to side.Center the assembly in the detector bracket. O Anlsu�AurarolAN" FIGURE 35 FIGURE 38 000503 8.Hook the fusible link on the ANSUL AUTOMAN release side of the hook assembly,then pull the fusible link to the opposite side and complete the hookup as shown in Figures 39 and 40. The top of the hook assembly must be inside the bracket stiff- eners.The hook assembly with the ANSUL fusible link in place must be located toward the terminal detector side of the bracket. FIGURE 36 2.3 IM11.� @ 0 b ra.r�n FIGURE 39 00004 FIGURE 37 CM,z 6.To give a constant tension on the wire rope during installation of the detector linkage, hang a vice grip or other weighted device on the excess stainless steel wire rope,leaving an ade- quate length of spare wire rope between the locking clamp and the weighted device. O d FIGURE 40 eon, I SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5-15 4-1-06 REV 3 INSTALLING THE DETECTION SYSTEM (Continued) Installing"Hinged"Style Linkage "Scissor"Style Linkage Installation(Continued) 1. Secure the conduit to the detector bracket using i/2 in.steel 14. Verify each detector linkage assembly,with correct fusible link, compression fittings.Thread the compression fitting into the is in the detector bracket, located fully toward the terminal detector bracket and then secure by using the lock nut sup- detector side. plied with the fitting.See Figure 46. NOTICE 12 IN.STEEL Due to the close adjustment between the trip COMPRESSION hammer and cable lever assemblies, use only f the particular fusible link(s)selected for installa- lo-IN.COMPRESSION—� tion in each detector, including terminal detec- PITTING NU tor, to ensure correct adjustment when perform- ing Steps 15 and 16. FIGURE 46 00=0 15. Raise trip hammer 3/8 in.to 1/2 in. (9.5 to 12.7 mm), pull all NOTICE slack out of wire rope, and tighten set screws on locking Do not use zinc die cast compression connec- clamp. tors on the detection conduit lines as zinc will 16. Lower tension lever to"DOWN"position and Inspect the base not withstand the normally high temperatures of the wire rope clamping device to make certain that there is experienced in the plenum area. a minimum of 1/4 in. (6.4 mm) and a maximum of 3/8 in. 2. Starting at the regulated release assembly, feed wire rope up (9.5 mm) clearance between the base of the trip hammer through hole in regulated release mechanism locking clamp, assembly and the cable lever assembly. See Figure 45. (if allowing excess wire rope to hang down. (Do not tighten set clearance is not between 1/4 in.(6.4 mm) or 3/8 in.(9.5 mm), screws in locking clamp at this time.) See Figure 47. raise tension lever, loosen set screws on locking clamp and repeat Steps 15 and 16.) CAUTION Make certain the hook assembly with the ANSUL fusible link in place is located toward the terminal detector side of . LOCKING each bracket.Failure to do so may restrict travel of detec- ' CLAMP tion line,causing system to malfunction. TRIP HAMMER ASSEMBLY FIGURE 47 000309 3. From the regulated release assembly, run the stainless steel (66..4 mm)IN.MINIMUM 3. rope through the conduit, pulley elbows and to the first 118 in.MAXIMUM detector. (9.5 MM) 4. Before continuing on past the detector bracket, feed the wire rope through the detector linkage assembly.See Figure 48. TRIP 5. Continue runningthe wire rope through the conduit and pulley HAMMER P 9 BASE elbows and feed it through each detector linkage assembly at �o each additional bracket. 6. At the terminal detector, feed wire rope through the terminal detector clamping device.Allow 2-3 in.(5-8 cm)of wire rope to 1 extend beyond the clamping device and wrench tighten the set screws.See Figure 48. 2a IN. (5-8 cm) FIGURE 45 OW%'3 e CAUTION �0 Do not install cartridge at this time as an accidental actu- ation could cause system discharge. FIGURE 48 17, Test detection system in accordance with the Testing and 0=2 Placing in Service Section, Page 7-1 —7-3, of this manual. 7. To give a constant tension on the wire rope during positioning of the detector linkage(s), hang a vise grip or other weighted 18. When testing has been completed,cut off excess wire rope in device on the excess stainless steel wire rope,leaving an ade- the regulated release assembly, leaving approximately 2 in, quate length of spare wire rope between the locking clamp (5.1 cm)of wire rope below the clamping device. and the weighted device. I SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 ! Page 5-17 4-1-06 REV.3 i INSTALLING THE DETECTION SYSTEyt(Continued) Installing"Hinged"Style Linkage(Continued) TRIP HAMMER l 13. Make certain tension lever is in the "UP" position. See ASSEMBLY Figure 53. It,%IN.MINIMUM KA mm) 18 in.MAXIMUM (7.5 mm) a� s i 1 , a TRIP HAMq� TENSION LEVER BASE fER O IN°UP"POSITION Vt tt,� FIGURE 53 COM.2 ►14. Verify each detector linkage assembly, with correct ANSUL FiGURE54 w23 fusible link, is approximately centered in the detector bracket. NOTICE ® CAUTION Due to the close adjustment between the trip hammer and cable lever assemblies, use only Do not install cartridge or do not remove lock bar at this the particular ANSUL fusible link(s)selected for time as an accidental actuation could cause system dis- the installation in each detector, including the charge. terminal detector, to ensure correct adjustment when performing Steps 15 and 16. 17. Test detection system in accordance with the "Testing and 15. Raise trip hammer 3/8 in. to 1/2 in. (9.5 to 12.7 mm), pull all Placing in Service;Testing Detection System section of this slack out of wire rope,and tighten set screw on locking clamp. manual. 16. Lower tension lever to"DOWN"position and inspect the base 18. When all testing has been completed in the 'Testing and of wire rope clamping device to make certain that there is a Placing in Service"section,cut off excess wire rope in the reg- minimum of 1/4 in. (6.4 mm) and a. maximum of 3/8 in. ulated release assembly, leaving approximately 2 in.(5.1 cm) (9.5mm) clearance between the base of trip hammer assem- of wire rope below the clamping device. bly and cable lever assembly.See Figure 54.(If clearance is not between 1/4 in.(6.4 mm)or 3/8 in.(9.5 mm),raise tension eCAUTION lever,loosen set screws on locking clamp and repeat Steps 15 and 16.) Make certain tension lever is In the"DOWN"position after completing all tests.Failure to put the tension lever in the "DOWN" position will cause the system to not operate properly. SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5-19 10-1-02 REV.4 INSTALLING REMOTE MANUAL PULL STATION (Continued) INSTALLING MECHANICAL GAS VALVE PULLEY TEE,PART NOTICE NO.427929 ONU Mechanical gas valves are designed for indoor installation only. To install each Mechanical Gas Shut-off Valve complete the fol- PD WS lowing steps.(All gas valve installation and testing shall be made in accordance with the authority having jurisdiction.) Note:Mechanical gas valve air cylinders)can be installed in reg- ulated release assemblies and also regulated actuator assem- blies. Installation in either is the same. 1. Make certain that regulated release assembly enclosure cover is detached and lock bar is properly inserted in the regulated CONNECT TO AIR CYLINDER FOR GAS oaOw release mechanism. VALVES AND CONNECT TO RELEASE TRIP LEVER FOR PULL STATIONS NOTICE CONTINUOUS WIRE ROPE Failure to follow these instructions may lead to system actuation. 2. Verify that cartridge has been removed from regulated release assembly and that the regulated release mechanism is in the OVAL SLEEVE. cocked position. 411NI;VIUhI OF PART N0.4596 If regulated release mechanism does not have lock bar insert- s IN.(152 mm) g (2)OVAL SLEEVES, ed or cartridge removed, refer to the"Semi-Annual Mainten- PART NO.4596, ance;' Page 8-1, in "Maintenance Examination"section, and NO EL9CWS ALLOWED complete Steps 2 and 3 before completing the following instal- MINIMUM OF CONNECT TO 6 IN,(152 mm) .--WHERE TWO WIRE AIR CYLINDER Cation steps. ROPES ARE PRESENT FOR GAS SPLICED VALVES AND 3. Remove plug from cartridge receiver.See Figure 57. CONTINUOUS WIRE ROPE ROpc \ CONNECT TO CARTRIDGE RECEIVER RELEASE TRIP LEVER FOR PULLEY TEE,PART PULL NO.427929 ONLY STATIONS I ► NOTE:EITHER BOTH MUST BE GAS VALVES OR BOTH MUST BE PULL STATIONS.MIXI<IG IS PLUG NOT ALLOWED. oo+»a FIGURE 56a FIGURE 57 6. Feed wire rope from each pull station through conduit and 4. Locate air cylinder and bracket assembly over the two 7/32 n9 each pulley elbow to cable lever located at regulated release assembly. (.6 cm) holes on right side of the enclosure. Assemble with screws, lockwashers, and nuts. Wrench tighten. See Figure NOTICE 58.Air cylinder(s) can also be mounted in the inverted posi- Make certain that wire rope rides on top and in tion, allowing for direct exit out the kriockout(s) in the bottom center of pulley sheave.If the 50 ft.(15 m)wire of the enclosure.See Figure 59. rope has been spliced to accommodate a longer FOR MOUNTING ONE MECHANICAL GAS VALVE run, do not allow the spliced ends to be within 6 in. (152 cm) of any pulley elbow or conduit WIRE ROPE /STOP SLEEVE adaptor. Jr/ 7, Fasten pull station assembly to each junction box(if junction box is used), MOUNTING BRACKET 8. Slide oval crimp sleeve onto wire rope.Loop wire rope through AIR CYLINDER cable lever guide holes and back through the oval crimp Roo sleeve.See Figure 55. 9. Pull slack out of each wire rope and crimp sleeve. (Use the National Telephone Supply Company Nicopress Sleeve Tool I o� o4C* Stock No.51-C-887 or equal to properly crimp stop sleeve.) See Figure 55. I I B IN.COPPER TUBING AND FITTINGS FIGURE 58 Mk7_1 w SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEx747 Page 5.21 4-1-06 REV.3 INSTALLING MECHANICAL GAS VALVE(Continued) ANSUL MECHANICAL GAS VALVES 6. Install the necessary 1/8 in.copper tubing and fittings for each air cylinder to the accessories piping arrangement on the reg- ulated release mechanism.See Figures 58 and 60, ° NOTICE ,D Do not kink 118 in.copper tubing or form a bend too close to a fitting.Secure each fitting without over tightening. Over tightening could result in pressure leakage or line separation at actuation. _ CORRECT WAY:�• VISE GRIP ENDS NEXT TO PIPE ® BEING INSERTED.PREVENTS EXCESS STRAIN ON VALVE BODY. To reduce the risk of explosion due to leaking gas, make 111111 certain that the gas line is turned off before connecting the �— gas valve. Install mechanical gas valve to its selected location in gas line so that it ensures safe shut-off to all predetermined appliances CORRECT WAY: being protected upon actuation of the system.Mechanical gas WRENCH CNSERTEE PREVENTS OO PIPE ° BEING WRONG WAY: valves may be mounted in any convenient horizontal or verti- EXCESS STRAIN ON VALVE BODY. ° WRENCH APPLIED cal position.See Figure 61. / AT THIS POINT �r a. Use new pipe,properly reamed and cleaned of metal chips. STRAINS VALVEBODY. b. Make certain gas flow is in the same direction as arrow shown on gas valve.To avoid cracking the gas valve cast- ing,do not overtighten pipe connections.If pipe tape,paste, spray, or similar lubricant is used, extra care should be taken to avoid overtightening. Apply lubricant to male threads only. c. Wrench tighten pipe to gas valve. DO NOT USE GAS VALVE AS A LEVER WHEN INSTALLING OR VALVE DAMAGE MAY OCCUR.See Figure 61. ASCO MECHANICAL GAS VALVES d. If strainer is utilized,attach strainer ahead of gas valve. e. If necessary, install drip leg in gas line in accordance with the authority having jurisdiction. I. The total length of wire rope allowed for Bach valve must not exceed 150 ft.(46 m). g. The maximum number of pulley elbows allowed for each gas valve is 20. CORRECT WAY: VISE GRIP APPLIED NEXT 4 TO PIPE BEING INSERTED 0PREVENTS EXCESS STRAIN ON VALVE BODY. moats CORRECT WAY: WRENCH APPLIED NEXT TO PIPE BEING INSERTED. PREVENTS EXCESS STRAIN ON VALVE BODY. WRONG WAY: WRENCH APPLIED AT THIS POINT STRAINS VALVE BODY. Ood]aa FIGURE 61 SECTION V — INSTALLATION INSTRUCTIONS UL EX.3470 ULC CEX747 Page 5-23 8-1-01 REV.3 INSTALLING ELECTRICAL GAS VALVES CORRECTWAY: NOTICE VISE GRIP E`IDS NEXT TO PIPE o , BEING INSERTED.PREVENTS Electric gas valves are designed for indoor EXCESS STRAIN!ON VAL`/E BODY. installation only. The following instructions and schematics illustrate methods of procedures for installing 110 VAC Electric Gas Shut-off Valves. 1. Make certain that regulated release assembly enclosure cover is detached and lock bar is properly inserted within the regu- lated release mechanism. NOTICE =�2 Failure to follow these instructions may lead to system actuation. CORRECT WAY: 2. Verify that cartridge has been removed from re g ulated release WRENCH APPLIED NEXT TO PIPE o WRONG WAY: BEING INSERTED PREVENTS assembly and that the regulated release mechanism is in the EXCESS STRAIN ON VALVE BODY. WRENCH APPLIED AT cocked position. THIS POINT STRAINS VALVE 000Y. If regulated release mechanism does not have lock bar insert- ed or cartridge removed, refer to the "Semi-Annual Mainten- ance,"Page 8-1, in "Maintenance Examination"section, and complete Steps 2 and 3 before completing the following instal- lation steps. 3. an wvi ® FIGURE 65 To reduce the risk of expl7turned 7beforeconneciing as make 4. Install and secure 1/2 in.conduit from each electric gas valve certain that the gas line is the to manual reset relay enclosure. gas valve. 5. Tag and connect electrical wiring to each electric gas valve. Then,feed wire through conduit to manual reset relay.Tape or Install each electric gas valve to its selected location in gas place a wire nut on any unused wire leads in accordance with line so that it ensures safe shut-off to all predetermined appli- authority having jurisdiction.Refer to Figures in"Design"sec- ances being protected upon actuation of the system,Refer to tion for typical wiring diagrams. ► manufacturer's instructions(if provided).See Figure 65. 6. a. Use new pipe properly reamed and clean of metal chips. b. Install valve so that the actuator is above the horizontal pipe line with no more than a five degree (5°) lean either way. Before working on any electrical wiring,make certain main power has been disconnected.Failure to disconnect main c. Make certain gas flow Is in the same direction as arrow power could cause personal injury or death if contact is shown on gas valve. made with energized wires. d. If strainer is utilized,attach strainer ahead of gas valve. Connect electrical wiring to-manual reset relay along with any e. If necessary, install drip leg in gas line in accordance with contactor, or contractor supplied devices needed. Refer to authority having jurisdiction. manufacturer's instructions and proper figure listed for assis- tance. 7. Tape or place a wire nut on any unused wire leads in accor- dance with authority having jurisdiction. 8. Install and secure 1/2 in. conduit from the regulated release assembly enclosure to manual reset relay enclosure. If snap-action switches have not been attached,go to"Electric Switch" section and install them at this time by completing Steps 3 through 8. 9. Tag and connect electrical wiring to each electric(snap-action) switch.Then, feed wire through conduit to manual reset relay. 10. Connect wiring from each electric (snap-action) switch to manual reset relay terminals.Refer to manufacturer's instruc- tions(if provided)and proper figure for assistance. 11. Tape or place a wire nut on any unused wire leads in accor- dance with authority having jurisdiction. 12. Properly return electrical power to the system. SECTION V — INSTALLATION INSTRUCTIONS UL EX.3.170 ULC CEx747 Page 5-25 4-1-06 REV.5 INSTALLING ALARM INITIATING SWITCH , The Alarm Initiating Switch Kit, Part CIO.4283 �,COnSIStS Of: END-OF-LINE RESISTOR FIRE ALAP,LI OR NEXT DEVICE • Alarm Initiating Switch Assembly—Rated 50 mA 28VDC CONTROL PANEL Spacer •----------- • Mounting Screw with Nut(2) • Extension Pin ALARM • Extension Pin Nut CIRCUIT ► I • Instruction Sheet ALAR&IINITIATING °�� The Alarm Initiating Switch is mounted in the ANSUL AUTOMAN SWITCH Release on the same mounting plate where the current snap- action switches are mounted.If the alarm initiating switch is used alone,the enclosed extension pin and pin nut are not needed. When mounting the switch, the spacer must be installed first, between the ANSUL AUTOMAN mounting plate (or existing switches) and the alarm initiating switch. See NFPA 72, "National Fire Alarm Code," Initiating Devices section, for the correct method of wiring connection to the fire alarm panel. After the switch is properly mounted, follow the steps listed in the installation section of the Design, Installation, Recharge, and Maintenance Manual for correct positioning of the switch lever on the ANSUL AUTOMAN cam surface. INCORRECT SPACER TOWARD SPACER SPACER AND AUTOMAN / SWITCH ARE PROPERLY Y/ MOUNTED,THIS DIVIDER MUST BE BETWEEN THE I 1 N.O.AND N.C,TERMINALS I I I I \• 0. COM I OUT IN IN •\ ® N.O. IN -SEPARATE INCOMING AND OUTGOING CONDUCTORS �\ `\ FIGURE 69 N.C. ALARM INITIATING SWITCH FIGURE 68 ON620 SECriwi VI — TESTING AND PLACING I,'ll SERVICE UL EX.3470 ULC CEx747 Page 6-1 3-1-04 REV.2 After the system has been completely installed, and BEFORE 6. Check burners for gaseous odor. IF GASEOUS ODOR INSTALLING THE CARTRIDGE,the system must be tested at the EXISTS, MANUALLY PUSH THE AIR CYLINDER ROD TO regulated release assembly, THE FULL "DOWN" POSITION IMMEDIATELY. This will cause the mechanical gas valve to shut the gas line off. TESTING MANUAL PULL STATION Open any doors and/or windows to clear the area of gaseous To test each remote manual pull station, complete the following fumes, then correct the gas leak before proceeding any steps: further. 1. With the expellant gas cartridge removed, remove lock bar 7. If no gaseous odor exists,pilot light may be ignited at this time. from regulated release assembly cable lever. 8. Reinstall side covers to gas valve housing.Make certain roll 2. On metal stamped pull station, remove glass break rod from pin is positioned within both sides of the valve housing slot. pull station by removing set screw on side of stud and slide Connect visual inspection seals(Part No.197)on ANSUL type glass break rod out.On molded plastic pull station,seal will be valves.See Figure 1. broken during test and must be replaced. 3. Pull ring handle on pull station.If the regulated release assem- b ly is tripped easily,the remote manual pull station Is properly Installed. If the regulated release assembly does not trip,remove pulley 1-4 tee(if provided)and each pulley elbow cover to make certain wire rope is resting on the pulley sheave.If this does not cor- rect the problem,there Is too much slack in the line and it must be retightened. 4. Cut off any excess wire rope 3/4 in.(2 cm)above oval sleeve. VISUALPECTION NO.197) 5. Recock regulated release assembly using cocking lever(Part No.14995)and reinstall lock bar(Part No.14985) 6. On metal stamped pull station, slide glass break rod through stud and ring handle.Tighten set screw into stud.On molded plastic pull station,replace seal. NOTICE If no other devices are being attached, proceed FIGURE 1 P. to Page 6-3, Step No. 1, and test the detection =359 system. 9. Make certain the regulated release mechanism is cocked with lock bar in place. TESTING MECHANICAL GAS VALVES NOTICE To test each mechanical gas shut-off valve complete the following If no other devices are being attached,proceed steps: to Page 6-3, Step No. 1, and test the detection 1 system. e QUTION To reduce the risk of explosion due to leaking gas,before the gas line is turned on, make certain to extinguish any open flames and turn off all burners and any electrical or mechanical devices that are capable of igniting gas. Turn gas line on. 2. Manually push each air cylinder rod to full "DOWN"position. The gas valve should close.If mechanical gas valve does not trip,remove each pulley elbow cover to make certain wire rope is resting on each pulley elbow sheave.If this does not correct the problem there may be too much slack in the line and it should be retightened. 3. Test for gas leaks by painting connections with a soap solu- tion. Bubbles indicate a gas leak.Tighten connections where leaks appear and repeat test again to make certain no other gas leaks exist. 4. If no gas leak is found,pull air cylinder rod to full"UP"position. 5. Recock mechanical gas valve. SECTION VI — TESTING AND PLACING IN SERVICE UL EX.3470 ULC CEx747 Page 6-3 10-1-02 REV.2 TESTING DETECTION SYSTEM 1. Test detection system by completing the following steps: 4. Upon successful actuation of the system,complete the follow- a. Raise the regulated release mechanism tension lever to the ing steps: "UP"position. a. Raise tension lever to"UP"position and install a properly- b. Remove the fusible link from the terminal detector and rated fusible link in the terminal detector. install a test link(Part No.15751).See Figure 2. b. Cock regulated release mechanism using cocking lever (Part No. 14995)and insert lock bar(Part No.14985). c. Lower tension lever to"DOWN"position. OQ d. Locate detector linkage and center in each bracket. For"clip on"style linkage, locate linkage in bracket slightly toward termination end of detection run. TEST LINK FIGURE 2 For"scissor"style linkage, locate linkage in bracket all the OOG363 way toward termination end of detection run. c. Locate detector linkage and center in each bracket. e. Make certain the 1/4 in. (6.4 mm) minimum to 318 in. For"clip on"style linkage, locate linkage in bracket slightly (9.5 mm)maximum clearance was maintained between the toward termination end of detection run. base of the trip hammer assembly and the cable lever assembly. For"scissor"style linkage, locate linkage in bracket all the NOTICE way toward termination end of detection run. Reset any electrical equipment that may have d. Lower regulated release mechanism tension lever to been affected by the system actuation. "DOWN"position and remove lock bar. I. Install appropriate cartridge into the regulated release e. Using a wire cutter,cut the test link at the terminal detector mechanism receiver and each regulated actuator receiver. to simulate automatic actuation. Hand tighten firmly. I. If system actuates successfully,go to Step 4. g. Remove the lock bar, . 2. If the regulated release mechanism does not actuate, check h. Install cover on regulated release assembly and each reg- the following components and remedy any disorder as follows: ulated actuator assembly and secure with appropriate fas- a. Check the detector linkage for correct positioning. teners or visual inspection seal. Insert seal (Part No. 197) in each upper and lower cover hole, if applicable.If system b. Check the wire rope for knotting or jamming. is install in an OEM enclosure, attach enclosure cover and c. Check pulley elbows to see that wire rope is free and cen- secure with appropriate hardware or procedure. tered in pulley sheaves. If any evidence of pulley elbow i. Record installation date on tag attached to unit and/or in a deformation is found,replace the pulley elbow. permanent file. d. Make certain that lock bar is removed. e. Make certain that regulated release mechanism is cocked. f. Make certain that tension lever is in"DOWN"position. 3. Re-test the system by completing the following steps: a. Make certain regulated release is cocked and lock bar Is inserted. b. Raise the regulated release mechanism tension lever to the "UP"position. c, Install a new test link (Part No. 15751) on the terminal detector. d. Lower the regulated release mechanism tension lever to the"DOWN"position. e. Check for 1/4 in.(6.4 mm)minimum 3/8 in.(9.5 mm)maxi- mum clearance between the trip hammer assembly and the cable lever assembly. I. Remove the lock bar. g. Using a wire cutter,cut the test link at the terminal detector to simulate automatic actuation. SECTION VII — RECHARGE AND RESETTING PROCEDURES UL EX.3470 ULC CEx747 Page 7-1 7-1-98 REV. 1 ►The recharge information listed in this section deals with the limi• RECHARGE tations and parameters of this pre-engineered system.Those indi- viduals responsible for the recharge of the R-102 system must be Determine the cause of system discharge and trained and hold a current ANSUL certificate in an R 102 training correct immediately before performing system ►program. recharge. For continued fire protection, the R-102 restaurant fire sup- 1. Remove the enclosure cover from the ANSUL AUTOMAN pression system must be recharged Immediately after use. regulated release assembly and each regulated actuator Recharge procedures for single, double, and multiple-tank sys- assembly. tems are as follows. 2. From tank in regulated release enclosure: Disconnect the ►CLEANUP PROCEDURES expellant gas hose from each tank adaptor assembly. Although there is no unusual cleanup procedure of ANSULEX or From tank in mounting bracket or mounting enclosure: ANSULEX Low pH agents, due to the alkaline nature of these Disconnect expellant gas piping union at each tank adaptor agents, they should be cleaned from kitchen surfaces within 24 inlet line(s), hours after system discharge.The reaction from the wet chemical 3. Disconnect distribution piping union at each tank adaptor out- agent on cooking grease or oil produces a foamy bi-product that let line(s). can be wiped up with a cloth or sponge.The following procedures should be followed: 4. From tank in enclosure:Remove tank. From tank in bracket assembly: Loosen wingnut, disengage ® • bracket band, and remove each tank. 5. Remove each tank adaptor/tube assembly and complete the Before attempting any cleanup, make certain that all fuel following: sources to the equipment to be cleaned have been shut off. Make certain that the exhaust hood and all appliance electrical a. Remove O-ring and inspect for damage. controls have been de-energized to avoid any chance of elec- b. Clean and coat O-ring with a good grade of extreme tem- trical shock resulting from the cleaning process or from electri- perature grease and reinstall into adaptor groove. See tally conductive alkaline liquid agent and/or its residue. Figure 1. Make certain all surfaces to be cleaned have cooled down to c. Remove 114 in.vent plug. room temperature. d. Clean and inspect for free movement and corrosion. Do not use water to clean any appliances that contain hot Replace if necessary. grease or cooking oils.Doing so may result in violent steaming e. Reinstall vent plug into adaptor body. and/or spattering. 1. The agent is non-toxic; however, food product and cooking grease/oil that has come in contact with the agent will no longer be suitable for human consumption and should be dis- carded. 2. Sponge up as much of the agent as possible using sponges or clean rags.Dispose of these sponges or rags in a local san- itary land fill site in accordance to local authorities.Note:Wear rubber gloves during cleanup as sensitive skin may become 0-RING irritated.If the ANSULEX agent or its residue comes in contact with skin or eyes, flush thoroughly with clean water. 3. Using hot, soapy water and either a clean cloth or sponge, FIGURE 1 wipe away all foamy residue and thoroughly scrub all surfaces aca a 6 that have come in contact with the agent. Note:Wear rubber • gloves during cleanup as sensitive skin may become irritated. If the ANSULEX agent or its residue comes in contact with Do not flush pipe with only water or other non-approved skin or eyes, flush thoroughly with clean water. material,as this could cause internal corrosion,leading to 4. After thoroughly cleaning all affected surfaces, adequately possible improper discharge. rinse and allow to completely dry before re-energizing the equipment. Piping system must be flushed to remove any wet chemical residue.To prepare the system for flushing: a. Pour the complete contents of one 32-oz.bottle of ANSUL Flushing Concentrate (Part No. 79656) into an empty R-102 agent tank. One complete bottle is used for either size tank,the 1.5 gallon or the 3.0 gallon. b. Fill the tank approximately half full with warm,clean water. Agitate the tank for a few seconds and then add more warm water to bring the fill level to within approximately 1 in.(2.5 cm)from the bottom of the fill opening. SECTION VII - RECHARGE AND RESETTING PROCEDURES UL EX.3470 ULC CEx747 Page 7.3 3-1-04 REV.4 RECHARGE(Continued) 10. Fill each tank with 1.5 (5.8 L) or 3.0 (11.6 L) gallons of only 26. Inspect the base-of the wire rope clamping device to make ANSULEX Low pH Liquid Fire Suppressant.Note:Use a fun- certain there is a minimum of 1/4 in.(6.4 mm) to a maximum nel with a screen to stop any foreign material from entering the of 3/8 in. (9.5 mm) clearance between the base of the trip tank.See Page 5-2.1, Figure 6,for detailed filling instructions. hammer assembly and the cable lever assembly. NOTICE CAUTION® If clearance is not 1/4 in.(6.4 mm) minimum to During filling, the agent temperature should be 60 °F to a maximum of 3/8 in. (9.5 mm), raise tension lever to "UP" position, raise trip hammer 3/8- 80 °F (16 °C to 27 °C). DO NOT FILL WITH COLD 1/2 in. (9.5-12.7 mm), tighten set screws, and AGENT. DO NOT OVERFILL. Overfilling may result in repeat Steps 25 and 26. agent entering gas hose and regulator potentially causing system malfunction. 27. Remove lock bar. 28. Manually test the regulated release mechanism by operating 11. Replace bursting disc, Part No.416974, in adaptor assembly. the remote manual pull station. Make certain silver side of disc is away from tank. 29. Recock the regulated release mechanism and insert the lock 12. Replace adaptor/tube assembly and tighten into place.Return bar. and secure each tank in regulated release assembly and 30. Reset all devices which were affected by the system actua- mounting brackettenclosure.Reconnect expellant gas and dis- tion.Refer to"Resetting"section, Page 7-3 and 7-4. tribution piping as required. 13. Raise tension lever to"UP"position. RESETTING 14. Cock regulated release mechanism using cocking lever (Part Resetting Remote Manual Pull Station No. 14995) and install lock bar(Part No.14985). Metal Stamped Style 15. Remove empty cartridge from regulated release assembly Reset each remote manual pull station by completing the following and each regulated actuator assembly as required. steps: ® 1. If necessary, remove set screw that is retaining the break AUTION glass rod. - FD, not install replacement cartridge at this time or system 2. If necessary, carefully remove any remaining broken glass may be actuated. from station. - 16. Install properly-rated fusible links in all detectors except the 3. Press and position ring handle in proper location against cover and slide the replacement glass break rod (Part No. 4834) terminal detector. through stud and handle. NOTICE 4. Tighten set screw into stud. If actuation was caused by a fire situation, all fusible links must be replaced. 5. If no other resetting is required, refer to"Cartridge Replace- 17. Install test link(Part No. 15751)in terminal detector. ment,"Page 7-4, and complete steps 1 through 5. 18. Lower tension lever to"DOWN"position. Molded Plastic Style 19. Remove the lock bar. 1. Position pull ring in vertical groove of pull station cover. 20. Using wire cutter, cut the test link at the terminal detector to 2. Insert break-away seal,Part No.79029,through holes in cover simulate automatic actuation, and snap in place. NOTICE If regulated release mechanism does not actu- ate, refer to Steps 2 and 3 of the 'Testing Detection System" portion of the "Testing and Placing In Service" section, Page 6-3, of this manual. 21. After successful actuation, raise the tension lever to "UP" position. 22. Install property-rated,ANSUL approved,fusible link in terminal detector. 23. Cock the regulated release mechanism and install lock bar (Part No. 14985). 24. Locate detector linkage and correctly position in each bracket. 25. Lower tension lever to"DOWN"position. SECTION VIII — MAINTENANCE EXAMINATION UL EX.3470 ULC CEx747 Page 8-1 3-1-04 REV.7 The maintenance information listed in this section deals With the 7. From tank in enclosure:Remove tank.Keep in upright position limitations and parameters of this pre-engineered system.Those to avoid spilling the agent. individuals responsible for the maintenance of the R-102 system From tank in bracket assembly: Loosen wingnut, disengage must be trained and hold a current ANSUL certificate in an R-102 bracket band, and remove each tank. Keep tank in upright training program. position to avoid spilling the agent. Maintenance is required semi-annually. At the 12 yaar interval, 8. Remove tank adaptor/tube assembly from each tank. See along with the normal maintenance exam, the tank(s) must be Figure 2. hydro-tested and the regulator(s)must be flow tested. ►Prior to performing the required maintenance steps,verity that the design of the system protects all of the original hazards when first installed. Make certain no additional hazards (appliances) have ►been added. SEMI-ANNUAL MAINTENANCE EXAMINATION Semi-annual maintenance procedures for single,double,and mul- tiple-tank systems are as follows. NOTICE Under certain circumstances hood and duct cleaning operations may render the fire sup- pression system ineffective due to a coating of cleaning chemical left on the detection equip- ment or mishandling of the system by cleaning service personnel. Therefore, it Is strongly recommended that the R-102 system be completely inspected and serviced by an FIGURE 2 authorized ANSUL distributor immediately 0GQ'9% following any such cleaning operations. 9. Make certain that each tank is filled with 1.5 (5.8 L) or 3.0 1. Remove the-enclosure cover from the ANSUL AUTOMAN (11.6 L) gallons of only ANSULEX Low pH Liquid Fire regulated release assembly and each regulated actuator Suppressant. See Figure 3. See Page 5-2.1, Figure 6, for detailed filling tolerances. - assembly. 10. Examine threads on each tank adaptor and tank collar for 2. Insert the lock bar (Part No. 14985) on the cocked regulated nicks, burrs, or cross-threading.Clean and coat O-ring with a release mechanism.See Figure 1. good grade of extreme temperature grease. See Figure 3. Remove 1/4 in.vent plug and clean and inspect for free move- ment and corrosion(replace if necessary).Reinstall vent plug. Make certain bursting disc is in place and silver side is away LOCK BAR from tank. Clean seating surface and return adaptor/tube PROPERLY assembly to each tank.Tighten securely. \ NSTALLED ` SILVER SIDE OF DISC AWN/FROM TAPIK FIGURE 1 O-RING 0003., 3. Remove cartridge from regulated release assembly and each regulated actuator assembly, install safety shipping cap, and FIGURE 3 set aside in a safe location. 0=6- 11. Place fully charged tanks in enclosures and/or brackets and 4. Remove gasket from cartridge receiver in regulated release secure. mechanism and each regulated actuator. Check gasket for elasticity or cuts and replace if necessary.Clean and coat gas- 12. Carefully assemble and wrench tighten all expellant gas and ket lightly with a good grade of extreme temperature grease. agent distribution piping, Reinstall gasket into cartridge receiver(s). 13. Remove blow-off caps from nozzles.Inspect each blow-off cap 5. From tank in regulated release assembly: Disconnect the and replace if deteriorated.On metal blow-off caps,make cer- expellant gas hose from each tank adaptor assembly. tain spring clip rotates freely on cap. From tank in bracket/enclosure assembly: Disconnect the NOTICE expellant gas piping union at each tank adaptor inlet line. Rubber blow-off caps that have been installed in 6. Disconnect distribution piping union at each tank adaptor out- the system for one year or more must be l replaced. et line. SECTION VIII — {MAINTENANCE EXAiMINATION UL EX.3470 ULC CEx747 Page 8-3 3-1-04 REV.4 SEMI-ANNUAL MAINTENANCE EXAMINATION(Continued) 29. If a mechanical gas valve is installed,begin the test procedure 23. Remove, clean, and return additional fusible links to series by removing both side covers. detector linkage(s). (Fusible links loaded with grease and 30. At the regulated release,push the air cylinder rod fully down. other extraneous material can result in excessive delays in actuation.) 31. The gas valve should operate. 24. Inspect wire rope at all detector locations, pulley elbows, pul- 32. Pull the air cylinder rod to its fully extended position. ley tee and at ANSUL AUTOMAN release.If wire rope shows 33. Re-cock the gas valve by pulling the valve stem up until the pin signs of wear or fraying, replace entire length. in the stem engages the cocking lever. 25. Lower the tension lever to"DOWN"position. 34. Reinstall side covers on the gas valve and connect the visual 26. Recock the regulated release mechanism and insert the lock indication seal. bar. 35. Test pressure switch by completing Steps No.1 through No.9 27. Inspect the base of the wire rope clamping device to make on Page 6-3 in Section 6,"Testing and Placing In Service.' certain that there is a minimum of 1/4 in.(6.4 mm)and a max- 36. Before reinstalling cartridge,reset all additional equipment by imum of 3/8 in. (9.5 mm)clearance between the base of the referring to appropriate section of "Recharge and Resetting trip hammer assembly and the cable lever assembly. See Procedures;'Section 7. Figure 7. 1 37. Remove shipping cap and weigh each cartridge. Replace if weight is 1/2 ounce (14.2 g),or more, below weight stamped 'SIP HAMMER ASSEMBLY on cartridge. 38. Make certain regulated release mechanism is cocked and lock bar is installed,then screw replacement cartridge into regulat- ed release mechanism and each regulated actuator receiv- 1/4 IN.(6.4 mm) er(s) and hand tighten. MINIMUM 39. Remove lock bar. 3/B IN.(9.5 MM) MAXIhIUM CAUTION Make certain tension lever is in the"DOWN"position after TRIP completing all tests.Failure to put the tension lever in the HAMt1ER BASE "DOWN" position will cause the system to not operate properly. 40. Snap cover on regulated release and each regulated actuator, ® insert visual seal (Part No. 197) through holes in cover and box,and secure. 41. Record semi-annual maintenance date on tag attached to unit and/or in a permanent file. FIGURE 7 rW-4 NOTICE If clearance is not between 1/4 in. (6.4 mm) or 3/8 in.(9,5 mm),raise tension lever to"UP"posi- tion, raise trip hammer 3/8-1/2 in. (9.5- 12.7 mm),tighten set screws,and repeat Steps 24 and 26. 28. Locate detector linkage and properly position in each bracket. For "clip on" style linkage, locate linkage in bracket slightly toward termination end of detection run. For"scissor"style linkage,locate linkage in bracket all the way toward termination end of detection run. SECTION Vill — (MAINTENANCE EXAMINATION UL EX.3470 ULC CEx747 Page 8-5 4-1-06 REV.4 - 12-YEAR MAINTENANCE EXAMINATION(Continued) For Second Tank:Disconnect expellant gas piping at union. 11. The regulator must be flow tested at 12 year intervals.Check Remove union from expellant gas piping and install pipe the date code stamped on the regulator body to determine if cap to prevent cartridge pressure from escaping during the regulator(s) requires the 12 year testing (see data code test.See Figure 10. table).If regulator does not require testing,proceed to step 12. Flow test the regulator(s)per the following: Date Code Table Month—Code Year—Code January A 1981 K February B 1982 L March C 1983 M April D 1984 N May E 1985 P June F 1986 R July G 1987 S August H 1988 T September J 1989 U October K 1990 V November L 1991 W December M 1992 Y 1993 Z 1994 A 1995 B FIGURE 10 1996 C CCQ770 1997 D Pressure Switch: If pressure switch is provided, it should 1998 E remain connected as part of system maintenance test.. 1999 F 2000 G NOTICE 2001 H For multiple-tank systems, one test kit (Part • 2002 J No. 56972) is required for each regulator in 2003 K the system. 2004 L b. Regulated Actuator 2005 M or E For First Tank: Disconnect expellant gas hose from tank. 2006 F Connect regulator test kit (Part No. 56972) to hose. See 2007 G Figure 11. a. Regulated Release Mechanism For First Tank: Disconnect expellant gas hose from tank. Connect regulator test kit (Part No. 56972) to hose. See Figure 9. POO FIGURE 11 FIGURE 9 - SECTION Vlll — MAINTENANCE EXAMINATION UL EX.3470 ULC CEx747 Page 8-7 4-1.06 REV.4 12-YEAR MAINTENANCE EXAMINATION(Continued) 19. Raise the tension lever to"UP"position.See Figure 16. 13. Refill each tank with 1.5 (5.8 L)or 3.0(11.6 L)gallons of only new ANSULEX Low pH Liquid Fire Suppressant.Note:Use a funnel with a screen to stop any foreign material from entering the tank. See Page 5-2.1, Figure 6, for detailed filling toler- ances. j 14. Clean seating surface and return each adaptor/tube assembly to tank. Firmly tighten. NOTICE 1 ' Do not reinstall any tank at this time. �' TENSION LEVER 15. Remove blow-off caps from nozzles.Inspect each blow-off cap O IN'UP'POSITION and replace if deteriorated.On metal blow-off caps,make cer tain spring clip rotates freely on cap. NOTICE Rubber blow-off caps that have been ` installed in the system for one year or more must be replaced. 16. Check all nozzles to ensure that they are free of cooking FIGURE 16 grease build-up and have a covering of clean silicone grease °0U3W on the orifice.Reinstall blow-off caps, 20. Install test link(Part No.15751) in terminal detector. 17, Remove lock bar and manually test the regulated release 21. Lower tension lever to"DOWN"position.See Figure 17. assembly by operating the remote manual pull station. 18. Cock the regulated release mechanism using cocking lever (Part No. 14995).See Figure 15. o i II TENSION LEVER i+I IN'DOWN"POSITION I I O � m ti 8 FIGURE 17 0019-9 22. Using wire cutter, cut test link at terminal detector to simulate automatic actuation. ® NOTICE If regulated release mechanism does not actuate, refer to Steps 2 and 3 of 'Testing Detection System"in'Testing and Placing in Service,"Section 6. FIGURE 15 23. After successful actuation, raise the tension lever to "UP" 00MM position. 24. Clean and return properly-rated,ANSUL approved,fusible link to terminal detector. NOTICE ' Fusible links installed in system for six ' months or more must be replaced. 25. Remove, clean, and return additional fusible links to series detector linkage(s). (Fusible links loaded with grease and other extraneous material can result in excessive delays in actuation_) SECTION IX - APPENDIX UL EX.3470 ULC CEx747 Page 9-1 10-1-02 REV.5 SYSTE941 SELECTION GUIDE Note: System options do not cover all conceivable variations.They are listed here as a general guideline to show the most common type arrangement for multiple systems, Based on certain system designs utilizing manifolding, non-manifolding, 3-tank systems, etc., other tank/cartridge combinations can be designed.The combinations below are based on 11 flow,3.0 gallon tanks and 5 flow, 1.5 gallon tanks. More competitive designs may be available by utilizing 12 flow and 6 flow systems when appropriate. 'Totai Tank Type of Carbon Dioxide Nitrogen Flow No.' Quantity System Iyie-QLHB[dDare Cartridge Reg_i1C C ri a-BIA fired 1-5 1 Single 1.5 Gal.Reg.Release 101-10(423439) LT-20-R(423429) 6-11 1 Single 3.0 Gal.Reg.Release 101-20(423441) LT-30-R(423435) 12-16 2 Double 1.5 Gal.Reg.Release 101-30(423443) Double (423493) 3.0 Gal.Additional Tank 17-22 2 Double 3.0 Gal.Reg.Release 101.30(423443)" Double(423493) 3.0 Gal.Additional Tank 23-33 3 Multiple 3.0 Gal,Reg.Release 101-20 (423441) LT-30-R(423435) 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal,Additional Tank 23-27 3 Multiple 1.5 Gal.Reg.Release 101-10(423439) LT-20-R(423429) (Optional) 3.0 Gal.Reg.Actuator 101-30(423443)"- LTA-101-30 (423491) 3.0 Gal.Additional Tank 28-33 3 Multiple 3.0 Gal.Reg.Release NIA Double(423493) (Optional) (2)3.0 Gal.Additional Tanks 34-38 4 Multiple 1.5 Gal.Reg.Release 101-10 (423439) LT-20-R(423435) 3.0 Gal.Reg.Actuator NIA LTA-101-30(423491) _ Double 3.0 Gal.Tank Box 34-38 4 Multiple 1.5 Gal.Reg.Release 101-30(423443) Double(423493) (Optional) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LTA-101-30(423491) 3.0 Gal.Additional Tank 39-44 4 Multiple 3.0 Gal.Reg.Release 101-20(423441) LT 30-R(423435) 3.0 gal.Reg-Actuator N/A LTA-101-30(423491) Double 3.0 Gal.Tank Box 39-44 4 Multiple 3.0 Gal.Reg.Release 101.30(423443)" Double(423493) (Optional) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LTA-101-30(423491) 3.0 Gal.Additional Tank 45-49 5 Multiple 1.5 Gal.Reg.Release 101-30(423443) Double(423493) 3.0 Gal.Additional Tank 3.0 Gal.Reg,Actuator N/A LT-A-101-30(423491) Double 3.0 Gal.Tank Box 45-49 5 Multiple 1.5 Gal.Reg.Release 101-10(423439) LT20-R(423429) (Optional) 3.0 Gal.Reg.Actuator 10 1-30(423443)"' LTA-101.30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank Based on 5 now numbers far a 1.5 gal.system and t I flow numbers for a 3.0 gal.system. If tank,are manifolded,only a'double tank'nitrogen avtrldge(Part No.423493)cart be used. "' If tanks are manifofded.either an LT-A-f01.30 nitrogen cartridge(Part No..123.191)or a double tank cartr'dge(Part No.423493)can be used. SECTION IX - APPENDIX UL EX.3470 ULC CEx747 Page 9-3 10-1-02 REV,5 - SYSTEM SELECTION GUIDE(Continued) ►Total Tank Type of Carbon Dioxide Nitrogen Flow No.* Quantity System Dpa 0f Hardware Cartridge Rea�Irari Cartridge" Required 78-82 8 Multiple 1.5 Gal.Reg.Release 101.30(423443) LT-30-R (423435) 3.0 Gal.Additional Tank (2)3.0 Gal.Reg.Actuator N/A (2) LT-A-101-30 (423491) (2) Double 3.0 Gal.Tank Box 78-82 8 Multiple Remote Mechanical Release 101-10(423439) -- (Optional) 3.0 Gal.Reg.Actuator 101-30(423443) LT-A-101-30(423491) 1.5 Gal.Additional Tank . 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30 (423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LTA-101-30(423491) 3.0 Gal.Additional Tank 83-88 8 Multiple 3.0 Gal,Reg. Release 101-30(423443) LT-30-R(423435) 3.0 Gal.Additional Tank (2)3.0 Gal.Reg,Actuator N/A (2) LTA-101-30 (423491) (2) Double 3.0 Gal.Tank Box 83-88 8 Multiple Remote Mechanical Release 101-10(423439) -- (Optional) 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30 (423491) 3.0 Gal.Additional Tank 89-99 9 Multiple Remote Mech.Release 101-10(423439) N/A (3)3.0 Gal.Reg.Actuator N/A (3) LT-A-101-30(423491) (3) Double 3.0 Gal.Tank Box 89-93 9 Multiple Remote Mechanical Release 101-10(423439) -- (Optional) 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)'-' LTA-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)'" LT-A-101-30(423491) 1.5 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-20(423441) LT 30-R(423435) 94-99 9 Multiple Remote Mechanical Release 101-10(423439) -- (Optional) 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-30(423443)"' LT-A-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 10 1-30(423443)"' LTA-101-30(423491) 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator 101-20(423441) LT-30-R(423435) Based on S flow numbers for a 1.5 gal.system and I I flow numbers for a 3.0 gal.system.if tanks are manifolded,only a'doatle tank'nitrogen cartrldgo(Part No.423493)can be used. ► ^' If tanks are manifolded,either an LT-A-101-3o nitrogen cartridge(Part Plo.42349 11 or a double tank rartridge(Part No.423493)ran be used. SECTION IX — APPENDIX UL EX.3470 ULC CEx747 Page 9-5 10-1-02 REV.5 SYSTEM COMPONENT INDEX Part No. Description Oart No. Description 429853 Mechanical ANSUL AUTOMAN 418054 OEM Regulated Electric Release Shipping Assembly (ULC Regulated Release Shipping Assembly g pP 9 y Also) Includes: Regulated Release Mechanism in Includes: Regulated Release Mechanism with Stainless Steel Mounting Enclosure Solenoid and Switch 1/4 in.Hose and Mounting Bracket 429856 Electric ANSUL AUTOMAN 79493 OEM Regulated Mechanical Release Shipping Regulated Release Shipping Assembly Includes: Regulated Release Mechanism with Assembly Solenoid and Switch in Includes: Regulated Release Mechanism Stainless Steel Mounting Enclosure 1/4 in.Hose and Mounting Bracket 429850 Regulated Actuator Shipping Assembly 418691 OEM Regulated Actuator Shipping Assembly (ULC Includes: Actuator and Regulator in Includes: Actuator and Regulator Also) Stainless Steel Mounting Enclosure Hose Bracket 429870 Stainless Steel Mounting Box Shipping Assembly (ULC Includes: Stainless Steel Mounting Box 429878 3,0 Gallon Bracket Assembly Also) I (Bracket Only) 429872 Two Tank Enclosure Shipping Assembly ► 32381 101 Remote Release Assembly (ULC Includes: Two(2) Expellant Gas Hoses 418522 OEM Regulated Actuator Shipping Assembly Also) Two(2) Grommets Includes: Actuator and Regulator Stainless Steel Mounting Box g Hose 429859 24 VDC Regulated Release Shipping Assembly (ULC) Includes: 24 VDC ANSUL AUTOMAN II-C 429862 3.0 Gallon Tank Shipping Assembly Release Mechanism in Stainless Steel Mounting Box 429864 1.5 Gallon Tank Shipping Assembly ►430299 3.0 Gallon Mechanical Release Shipping Assembly including: 56972 Regulator Test Kit 429853 Mechanical Regulated Release Assembly Includes: Gauge, Hose and Valve Assembly 429862 3.0 Gallon Tank Assembly 79694 1.5 Gallon(5.8 L)Container of ANSULEX Low pH 430300 1.5 Gallon Mechanical Release Shipping Assembly Liquid Fire Suppressant including 79372 3.0 Gallon (11.6 L)Container of ANSULEX Low pH 429853 Mechanical Regulated Release Assembly 429864 1.5 Gallon Tank Assembly Liquid Fire 5uppressant 430309 3.0 Gallon Regulated Actuator Shipping Assembly ►423429 Cartridge Shipping Assembly(LT-20-R) (TC/DOT) including: 429850 Regulated Actuator Assembly 423435 Cartridge Shipping Assembly(LT-30-R) (TC/DOT) 429862 3.0 Gallon Tank Assembly 430316 1.5 Gallon Stainless Steel Enclosure Shipping 423493 Cartridge Shipping Assembly(R-102 Double-Tank) Assembly Including: (TC/DOT) 429870 Single Tank Mounting Box Assembly 429864 1.5 Gallon Tank Assembly 423491 Cartridge Shipping Assembly(LT-A-101-30) (TC/DOT) 430317 3.0 Gallon Stainless Steel Enclosure Shipping 423439 Cartridge Shipping Assembly(101-10) (TC/DOT) Assembly including: 429870 Single Tank Mounting Box Assembly 15850 Cartridge Shipping Assembly(101-10)(DOT) 429862 3.0 Gallon Tank Assembly 423441 Cartridge Shipping Assembly(101-20) (TC/DOT) 430324 6.0 Gallon Stainless Steel Enclosure Shipping Assembly including: 1423443 Cartridge Shipping Assembly(101-30)(TC/DOT) 429872 Two Tank Mounting Box Assembly 419347 Nozzle Shipping Assembly(1 W) 429862 3.0 Gallon Tank Assembly(2) Includes: 25 1 W Nozzles(Part No.419336) 430332 3.0 Gallon Mounting Bracket Shipping Assembly -25 Blow-Off Caps including: 419345 Nozzle Shipping Assembly(1/2N) 429878 3.0 Gallon Mounting Bracket Assembly Includes: 9 1/21\1 Nozzles (Part No.419334) ► 429862 3.0 Gallon Tank Assembly 9 Blow-Off Caps SECTION IX - APPENDIX UL EX.3470 ULC CEX747 Page 9-6.1 4-1-06 REV.4 - SYSTEM COMPONENT INDEX(Continued) Part No. DescrlAtfon Part No. Description 17643 Gas Shut-off Equipment(Electrical 110 VAC, 60 Hz) 423435 Recharge Equipment Includes: Fluid Power Gas Valve-3 in. Includes: LT30-R Cartridge 426151 Gas Shut-off Equipment(Electrical 110 VAC,60 Hz) Includes: Relay-Manual Reset 423493 Recharge Equipment 423878 One Electric Switch (Field Mounted) Kit Includes: Double System Cartridge Includes: Electric Switch(SPDT), 423491 Recharge Equipment Mounting Hardware Includes: LTA-101-30 Cartridge 423879 Two Electric Switch(Field Mounted) Kit 423439 Recharge Equipment Includes: 2 Electric Switches(SPDT), Includes: 101.10 Cartridge Mounting Hardware 423880 Three Electric Switch (Field Mounted)Kit 423441 Recharge Equipment Includes: 3 Electric Switches(SPDT), Includes: 101-20 Cartridge Mounting Hardware 423443 Recharge Equipment 423881 Four Electric Switch (Field I',tounted) Kt Includes: 101-30 Cartridge Includes: 4 Electric Switches(SPDT), 79372 Recharge Equipment Mounting Hardware Includes: 3.0 Gallon(11.4 L)Container of 428311 Alarm Initiating Switch Kit ANSULEX Low pH Liquid Fire Suppressant 55598 Gas Shut-off Equipment Mechanical(ANSUL) 79694 Recharge Equipment Includes: Mechanical Gas Valve-3/4 in. Includes: 1.5 Gallon(5.7 L) Container of 55601 Gas Shut-off Equipment Mechanical (ANSUL) ANSULEX Low pH Liquid Fire Suppressant Includes: Mechanical Gas Valve-1 in. 417911 Recharge Equipment 55604 Gas Shut-off Equipment Mechanical(ANSUL) Includes: Package of 10 Tank Adaptor Bursting Includes: Mechanical Gas Valve-1 1/4 in. Discs 55607 Gas Shut-off Equipment Mechanical(ANSUL) 77695 Recharge Equipment Includes: Mechanical Gas Valve-1 1/2 in. Includes: 50 Blow-Off Caps 55610 Gas Shut-off Equipment Mechanical(ANSUL) 24916 Recharge Equipment Includes: Mechanical Gas Valve-2 in. Includes: 10 Test Links(Part No. 15751) 25937 Gas Shut-off Equipment Mechanical (ASCO) 415739 Recharge Equipment Includes: Mechanical Gas Valve-2 1/2 in. Includes: Fusible Link 165 IF(74 IC) 25938 Gas Shut-off Equipment Mechanical (ASCO) 415740 Recharge Equipment Includes: Mechanical Gas Valve-3 in. Includes: Fusible Link 212 OF(100 IC) 15733 Gas Shut-off Equipment 415744 Recharge Equipment Includes: Air Cylinder and Tube Assembly Includes: 25 Fusible Links 280°F(138°C) 4835 Remote Manual Pull Station-Metal Stamped (Part No.415741) Includes: Remote Manual Pull Station Assembly 415745 Recharge Equipment 50 Ft.(15 m)of Wire Rope Includes: 25 Fusible Links 360 of(182°C) 24915 Break Rod Package (Part No.415742) Includes: 10 Glass Break Rods (Part No.4834) 415746 Recharge Equipment (Replacement) Includes: 25 Fusible Links 450 OF(232 IC) 427074 Trim Rings(Pack of 10) (Part No.415743) 31809 16 in.(41 cm) Stainless Steel Actuation Hose 73867 Recharge Equipment 32335 20 in.(51 cm)Stainless Steel Actuation Hose Includes: 25 Fusible Links 500 IF(260 IC) 32336 24 in.(61 cm)Stainless Steel Actuation Hose (Part No.56816) 430815 42 in.(107 cm)Stainless Steel Actuation Hose 423429 Recharge Equipment Includes: LT-20-R Cartridge SECTION IX — APPENDIX UL EX.3470 ULC CEx747 Page 9-7 10-1-02 REV 3 "ANSUL AUTONIAN"REGULATED RELEASE ASSEMBLY 3 I-► 'O O O O O 14(ORDERED i SEPARATEL:O / /( 6 Q ® �7 13 2 16 12 40'®D- m 9 6 O � 18 19,20 17 Figure Mechanical Electrical No, D cr' i r� Part No, Part No, Regulated Release Shipping Assembly 429853 429856 1 Mounting Box 419293 419293 2 Basic Release w/Regulator 79140 — Basic Release w/Solenoid, Switch, and Regulator — 79288 3 Self-Tapping Screw 71342 71342 4 Spacer 76555 76555 5 Tension Spring 79094 79094 6 Lever and Bracket Assembly 79300 79300 ► 7 Machine Screw 14973 14973 8 Lockwasher 7310 7310 9 Hex Nut 14732 14732 10 Caution Label 57652 57652 11 Gasket 181 181 12 Expellant Gas Cartridge Assembly ► LT30-R/101-20(Ordered Separately) 423435/423441 4234351423441 ► Double Tank/101-30(Ordered Separately) 423493/423443 423443/423443 13 Safety Shipping Cap 77251 77251 14 Tank Assembly 1.5/3.0 Gal. (Ordered Separately) 4298641429862 429864/429862 15 Hose Assembly 79007 79007 ► 16 Enclosure Cover(Includes Label) 423744 423744 1, 17 Solenoid Assembly — 423575 18 Electric Snap-Action Switch — 423878 19 Cover Screw 15362 15362 20 Speed Nut 423479 423479 SECTION IX — APPENDIX UL EX.3470 ULC CEx747 Page 9-9 4-1-06 REV.4 i ENCLOSURE ASSEMBLY 0 J_►*7 q° o ' 0 3 2 0 rJ acorn 0 a 0 Figure h o Description Part No. — Enclosure Shipping Assembly 429870 1 Enclosure 419295 2 Cover 419296 3 Nameplate 429871 4 Screw 15362 5 Speed Nut 423479 i SECTION IX — APPENDIX UL EX.3470 ULC CEx747 Page 9-10.1 4-1-06 REV.3 TANK ASSEMBLY 6 5 3 7;. - l 2 B-► i tuu;s Figure 1.5 Gallon 3.0 Gallon Descrin Part Nq__ Part No. Tank Assembly 429864 429862 1 Tank Adaptor Shipping Assembly 430096 79522 2 Pickup Tube Assembly 429883 417700 3 Vent Plug Assembly 74247 74247 4 O-Ring 56909 56909 5 Union Nut 417705 417705 6 Union Tail Piece 417706 417706 7 Burst Disc 416974 416974 8 Shell 429861 429860 9 Nameplate NIA N/A 1� .. ,.. - n. - •°woev-.•�•. vx.•"a. •" ..- .,- p"• - _eSTe-+•'.h'xz^T�i'?4"'•,"'C$ER,X�T. .. R 3"_9!'1Gffi. P.Y'lt.+"o. '?"2xR-ftY4.T:9`S'�:','.1.4::�'J?':TA:!°'t3'.bY,34+RffiR^C'i^"�`✓`":'%[Y?YA'Y3:2„'+&YrhP+�•-"'A.Tf..q'n41R+T'Se'•'LH'w"1}.;Ts.�x.RSdHfp:^' .. _ fA`.k".' _ ESP1.'3Pa'V!:>P3'gnf6�&SCVLYI3."^!f . -- -- .A. ..GiBtK��1864F9 v -. ..Y.�'7"+^�.Y:C•NN1?'L"-J�H{RES=M1t.V'i'^MY4'.'3T8'.�`%+:F.,*"Y�iie"S.;E�°iM�R`+'q`t'wl9sWmmeAAtia4!:�✓LTti."=a.e.Y:�ffi;r�?�f{di%94a^Ri•MME�*.RI[i'CI¢�'f'SYFflNBR,�G�4�6iK.++AQM'. - - :!`MJ tag.. i, _ .•.F 'X�M1�. - :9Y »=.'�S$yo- ^�'aM:•d _ _ - ,., .,�... 1v.:_r"".e4:1'TL'�",.•:`9T.. &1 � .,..'^:9!"T.`T!'.r...-.. ..- ...- - -. ..:... "'TLR.. ...^�.yR+^",,..,a:,^?�:.eP"$!"! ^.e'?yt_.�"'... ......'.'4°j'!:^e'T„^i""�?"�...ye+r.s+.±!r='R..?',.�,!ec°.,'y'.'.^'.'n"^,�'^'^'^'.....,+nr.wr�,. ,�r�.-w'...eT'.'°:sID^,?!"a§x"R!.�A.`S^'!'Mu f!^'n.:"�;""+rY!S<@Ji!+'!9v^."'L.=,... .. '"T'-�ar°T_W4 ., `�,^r^"W:'!',-..`9 ". . ... - - rt.'{- .e.4'.i488!�fiMrs`i""T3} _ _ - _ - - :� .. .- -•__ Z;idT5A7°''i! � "R9t^Jt�✓�fi1A'�•+G SF � /'R�R�-mf �T'+ +'�`"5':F.�': •+Ate"vx6'4 ---NERAL NOTES: SAFETY NOTES: RESIDENTIAL RENOVATION &CONsfRLJCTION SILVER SANDS MOTEL FIRE SEPARATION BETWEEN DOOM #12 AND LOBBY ACTOR N 0 TE General Notes: qqFLL 1. GENERAL: ALL WORK TO BE COMPLETED IN ACCORDANCE WITH THE TOWN OF SOUTHOLD, NEW YORK, 2020 BUILDING CODE OF I FL1 F I CP'11'71 Wood: NEW YORK, AND REGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION- 1' I GENERAL NOTES: All studs to be SPF #2 or better, ant all other structural wood to be Douglas Fir/Larch #2 or better. UL DESIGN NO. U305 "-4' 1'-4' Type X Sheetrock Ld31 _ 2. All structural wood shall be in accordance with the national design specifications for wood construction - latest edition. 2. FIRE SAFETY: k t- ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE TOWN OF SOUTHOLD, SUFFOLK COUNTY, NEW YORK, 2020 RESIDENTIAL A. ALL BUILDING MATERIALS WHICH ARE STORED AT THE SITE OR ANY AREA OF THE BUILDING ARE TO BE STORED IN A FIRE RATPIG. 1HR a CODE OF NEW YORK, FIRE DEPARTMENT RULES AND REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE 3. Nailing schedule shall be in accordant= with the specified code. B- LOCKED AREA. = STC 36 M KEHL DESIGN ASSOCIATES, LLI. PRACTICES. FIRE SEPARATION WALL FIRE SEPARATION WALL }° 2. 4. Pre-manufactured trusses. C. ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION 1A DESICN NO U301 = UL DESIGN NO IIjn1 SYSTEM THICKNESS 4g_ _ BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF a. All trusses shall be "shaped" cs shown on architectural cross sections. D4 WALL 2HR 216 WALL 2LF residential & commercial design o consulting BUILDINGS, OBTAIN ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, b. Trusses shall bear o boa number and shall be manufactured by o registered manufacturer. D. ALL FLAMMABLE MATERIALS TO BE KEPT TIGHTLY SEALED IN THEIR RESPECTIVE MANUFACTURER'S CONTAINERS. SUCH 0 3"Thick e Type X Sheetrock FMineral Wool 2x4 Wood Studs AND PAY ALL FEES REQUIRED BY THE GOVERNING BODY OF THE TOWN OF SOUTHOLD, NEW YORK, AGENCIES MATERIALS ARE TO BE KEPT AWAY FROM HEAT. ALL WALLS AND CEILINGS nsulntion 16"oc 3. S. Erect and brace trusses in accordance to truss plate institute recommendations. TO EE COVERED wiH =-`- E. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN ADEQUATELY VENTILATED SPACE. s ASSEMBLY OPTIONS: MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT REQUIRED FOR PROPER CONSTRUCITON OF ANY PART OF THE WORK TYPE"X"SHEETROCK I NOTES: SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. 6. Plywood sheathing. F. ALL ELECTRICAL POWER TO BE SHUT OFF WHERE THERE ARE EXPOSED CONDUITS. FIRE SEPARAIION WALL P0.Box 1675 phone: (631J 433-9084 4. a. All plywood sholl be in accordance with the American Plywood Association (APA) specifications. - UL DESIGN NO U301 SILVER SANDS ROOM #12 81 i' LOBBY THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH THE STIPULATIONS OF LOCAL AUTHORITIES, AND OWNER. b. Plywood sheathingshall be cortinuous over two or more spans with groin of face pl s across supports G. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS. 2X4 WALL 21'R s GYPSUM HOARD: ONE LAYERS THICK GYPSUM BOARD°TYFE X" STUDS AND INSULATION SIZES ARE MINIL9UM UNLESS OTHERIMSE STATED IN DESIGN Southold,NewYork 11971 E-Mail; ssbn654aoptonline.net 5. corporation or equal. g y CONTRACTOR, AT ALL TIMES, TO ENSURE THERE IS NO NATURAL GAS LEAKAGE IN THE BUILDINGS, OR ANY FLAMMABLE ROOM #12 MOTEL NTS NTS WOOD STUDS. 2X4 WOOD STUDS 16 CC. q THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED 5 1/2" FOR THr MOST UP ID DATE INFORMATION OR ASSWRLY OPTIONS,REFEP TO THE R - b a NFPA 13 S rinkler Stem s• This Room is to be Proleded FIRE SEPAPATION WALL _LL WALLS AND CEIUNCC INSULATION. 3 MINERAL WOOL INSULATION IN CAVITY UL FIRE RESISTANCE DIRECTORY. CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL 0 GAS TO BE USED DURING CONSTRUCTION. t° 7. All sills shall be pressure preservative treated (.4 PSF retention) SYP �2 or better. NTS LOBBY V P ys UL DESIGN N0.U301 Ito BE COVEPEO WITH o_ ? Kehl Design Associates,LLC o formerly D A K Associates,LLC REMOVAL TASKS. THE CONTRACTOR THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY FIRE SEPARATION 2X6 WALL 2HR 'Y "X"SHEETROCK GYPSUM BOARD: ONE LAYERS THICK GYPSUM RDARD "TYPE X° -7.? ?7�T// /-TT�'-;r'!' �% " " OR DURING THE EXECUTION OF THE WORK. 3. DUST CONTROL: This Room is to be Protecled KES I REFER TO THE UL FIRE RESISTANCE DIRECTORY FOR INFORMATION REGARDING 8. Design values: - ALL WALLS AND CEILINGS 6 by a NFPA 13 Sprinkler System PRODUCT ORIENTATION AND FASTENING REQUIREMENTS. OWNERSHIP & USE OF DOCUMENTS: THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES: a. Framing Lumber: DF (north) No. 2 or better A. DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM AND CONFINED TO THE IMMEDIATE CONSTRUCTION AREA. _ i0 BE COVEPED WITH " E = 1,600,000 PSI BETWEEN ROOM #12 PLUMBING, ELECTRICALS, ETC. B. CONTRACTOR TO ISOLATE CONTRUCTION AREA FROM OCCUPIED BUILDING AREA BY MEANS OF TEMPORARY PARTITIONS OR FIRE SEPARATION WALL TYPE"ziYPE SHEE ROCK Fv = 95 PSI UL DESt6IJ Flo U301 1'-4" t -4" s'Type%Sheetrock These drawings and specifications including the T Fla - 825 PSI C. HEAVY DROP CLOTHS. ALL WALLS AND CEILINGS == UL DESIGN NO. U3O1 I PLUMBING WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN THROUGH r _ 2X6 WALL 2HP AND LOBBY s TypeX$heetrock ideas, design and arrangements represented THE DEPARTMENT OF BUILDINGS ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS. DEBRIS, DIRT, AN DUST TO BE CLEANED UP AND CLEARED FROM THE BUILDING SITE PERIODICALLY TO AVOID EXCESSIVE TO BE COVERED WTH- FIRE SEPARATION WALL 8 9. Design values: therein, are the property of KEHL DESIGN a. Laminated Veneer Lumber (LVLI: ACCUMULATION. TYPE UL DESIGN NO U301 FIRE RATING: 2HR ELECTRICAL WORK SHALL BE PERFORMED BE PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN E _ 1,900,000 PSI 8"CMU 2HR ASSOCIATES, LLC. No part thereof shall be THROUGH THE BUREAU OF ELECTRICAL CONTROL ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS. ALL WALLS atlD CEIurJGS STC: NA copied, disclosed to others or used In connection Fv = 285 PSI 4. NOISE AFTER HOURS: 9 ffn THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPARING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE Fla = 2600 PSI TO BE COVERED WTH r _ SYSTEM THICKNESS 6 with any work or project other than for which DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB. A. CONSTRUCTION OPERATIONS WILL BE CONFINED TO NORMAL WORKING HOURS: 8AM TO 6PM, MONDAY TO FRIDAY, IYPE'X"SHEETROCKSHEETROCK T e X Sheetrock 3}"Thick 2xa wood staa5 a they have been prepared without written consent. NOTE- NOTE PROVIDE FIRE CAULKING AT ALL HORIZONTAL AN) VERTICAL PENETRATIONS Mineral Waal �'type X Sheetrock 10. B. EXCEPT LEGAL HOLIDAYS. ASSEMBLY OPTIONS Insulation 16'oc. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED. 11 CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM ALL AFFECTED PARTIES TO WORK OTHER THAN REGULAR HOURS. 1 HR FIRE-RATED WALL CONSTRUCTION BETWEEN MOTEL IN FIREWALL AS PER THE 2020 FIRE CODE OF N-W YORK STATE ALL DIMENSIONS ARE ESTABLISHED FROM THE FINISH LEVEL OF THE FIRST FLOOR. VARIATIONS TO THE HEIGHT OF THE FINISH LEVEL NOTES REV. OF THE FIRST FLOOR ARE TO BE REVIEWED FOR APPROVAL BY THE OWNER AND KEHL DESIGN ASSOCIATES LLC. NO CONSTRUCTION 5 CONSTRUCTION OPERATIONS WILL NOT INVOLVE INTERRUPTION OF HEATING, WATER, OR ELECTRICAL SERVICES TO THE OWNER. ROOMS AS PER THE 2020 BUILDING CODE OF NEW YORK GYPSUM BOARD: TWO LAYERS THICK GYPSUM BOARD"TYPE X" WILL BE ALLOWED TO COMMENCE UNTIL THIS HEIGHT IS APPROVED. CONSTRUCTION WORK WILL BE CONFINED TO THE WORK ISSUED, AND WILL NOT CREATE DUST, DIRT, OR OTHER SUCH NOTE: PROVIDE ROCKWOOL FIRE AND SOUNDPROOFING I`1SULATION IN ALL WALL STUDS AND INSULATION SIZES ARE MINIhRJM UNLESS OTHERWSE STATED IN DESIGN. JANUARY 22, 2023 WOOD STUDS 2x4 WOOD STUDS 16"OC. JANUARY 25, 2023 1 2. INCONVENIENCES TO THE OTHER NEIGHHBORS. INSULATION: 3'' MINERAL WOOL INSULATION IN CAVITY FOR THE MOST UP TO DATE INFORMATION OR ASSEMBLY OPTIONS REFER i0 THE FEBRUARY 22, 2023 THE CONTRACTOR IN COORDINATING THE WORK WILL REPORT ANY DISCREPANCIES TO THE ENGINEER'S ATTENTION FOR IMMEDIATE RESOLUTION. 6 SPECIAL SAFETY NOTES 1 3 GYPSUM BOARD TWO LAYERS THICK GYPSUM BOARD"TYPE X" UL FIRE RESISTANCE DIRECTORY. THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ALL UTILITY LINES WITH THIS AND RELATED SITE WORK, AND ALL CONTRACTORS AND THEIR REPRESENTATIVES WORKING ON THIS PROJECT SHALL AT ALL TIMES PRIOR AND DURING THE COURSE APRIL 20, 2023 HE WILL BE RESPONSIBLE FOR ALL DISCONNECTIONS, RECONNECTIONS, AND STARTUPS. OF THEIR ACTIVITY BE RESPONSIBLE FOR THE SAFETY OF THEIR EMPLOYEES AS WELL AS OTHERS AND IN THE CARE OF THE REFER TO THE UL FIRE RESISTANCE DIRECTORY FOR t FORMATION REGARDING JUNE 11, 2023 14 PROPERTY. EACH AS REPRESENTATIVES OF THEIR EMPLOYEES SHALL ASCERTAIN THAT THE CONDITIONS UNDER WHICH THEY WILL BE PRODUCT ORIENTATION AND FASTENING REQUIREMENTS. JUNE 13, 2023 THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ELECTRICAL, PLUMBING, AND HVAC EQUIPMENT WITH REQUIRED TO ACCOMPLISH THEIR WORK ARE SAFE WITHIN GOOD SAFETY PRACTICES AND MEET ALL CONCERNED REGULATIONS OF SILVER SANDS MOTEL FIRE SEPARATION BETWEEN LOBBY AND ROOM #11 ARCHITECTURAL FEATURES AND STRUCTURE. ANY CONFLICTS WILL BE BROUGHT TO THE ENGINEER'S ATTENTION FOR IMMEDIATE THE OCCUPATIONAL SAFETY AND HAZARD ACT OR OTHER GOVERNING REGULATIONS. THE BEGINNING OF WORK BY A CONTRACTOR RESOLUTION. SHALL INDICATE SATISFACTION CONCERNING SAFETY AND FULL RESPONSIBILITY FOR ACCIDENTS OR DAMAGE. IF UNSATISFIED, THE r Type X Sheetrock 1. 4" 1 4° CONTRACTOR SHALL INDICATE WHATEVER ACTION NECESSARY, OR RENDER SAFETY CONDITIONS FOR LIFE AND PROPERTY AS ARE UL DESIGN NO. U3O1 e'Type X Sheetrock RELATED TO HIS ACTIVITY. IF THE WORK OF OTHER PARTIES OUTSIDE OF THE ORGANIZATION IS UPON INSPECTION FOUND AT ANY TIME TO BE UNSAFE, HE SHOULD STOP WORK IMMEDIATELY AND NOTIFY THE GENERAL CONTRACTOR, KEHL DESIGN ASSOCIATES LLC, OR OWNER. THE BEGINNING OF WORK SHALL INDICATE SATISFACTION WITH CONDITIONS AND ACCEPTANCE OF THESE REQUIREMENTS. FIRE RATING: 2HR ALTERATION LEVEL #3 AS PER THE 2020 EXISTING BUILDING CODE OF NEW YORK _ sic 42 L SYS TEM THICKNESS 8"WALL FIRE RATING FIRE SEPARATION WALLCLIMATIC AND GEOGRAPHIC DESIGN CRITERIA ALL WALLS AND CEILINGS UL DESIGN NO UNI UL DESIGN NO U301 51'Thick 2x6 Wood Studs Type X Sheetrock GROUND WIND SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE SHIELD CLIMATE ZONE TO BE COVERED W1H y' = FIRE SEPARATION WALL ALL WALLS AND CEN_INGS 2X4 WALL 2HP 2X4 WALL 2HR ASSEMBLY OPTIONS. Mineral Wool iCoe �'Type X Sheetrock /7 SNOW DESIGN FROST LINE DESIGN UNDERLAY- FLOOD WIND EXPOSURE _ - LOAD SPEED (mph) CATEGORY WEATHERING DEPTH TERMITE DECAY TEMP. MENT REQUIRED HAZARDS CATEGORY [RESIDENTIAL COMMERCIAL TYPE'X"SHEETROCK - UL DESIGN N0.U301 TO BE COVERED WTH�" nsua ion 25 Ibs/sgft 130 (mph) C SEVERE 3'-0" MODERATE TO HEAVY SLIGHT TO MODERATE Ill degrees YES 1984/1998 C 4A 4A - UTI LTY- 2X4 WALL 2HR TYPE"X"SHEEIROCK NOTES: - GYPSUM BOARD. TWO LAYERS °THICK GYPSUM BOARD"TYPE X" DESIGN CRITERIA 2018 International Energy Conservation Code (IECC) ROOM ° LOBBY 8„ ROOM #11 WODD STUDS 2X6 WOOD STUDS i6'CC STUDS AND INSULATION SIZES ARE MINIMUM UNLESS OTHERWSE STATED IN DESIGN N 0 SUBSTITUTIONS IN _ INSULATION: 51"MINERAL WOOL INSULATION IN CAVITY FOR THE MOST UP TO DATE INFORMATION OR ASSEMRLY OPTIONS,REFER TO THE PRESCRIPTIVE DESIGN - N.TS 3 1 2" 3 1 2" NTS. LOBBY ROOM #111: WALL FIRE RATING/ / FIRE SEPARATION WALL GYPSUM BOARD Two LAYERS�' THICK GYPSUM BOARD"TYPE X° UL FIRE RESISTANCE DIRECTORY. _ = SILVER SANDS UTILTY UL DESIGN NO U301 This Rom 1 !a be Protected ul DESIGN N0.U301 by a u:_A 13R Sprinkler system REFER TO THE UL FIRE RESISTANCE DIRECTORY FOR INFORMATION REGARDING Llccc(s) AND ^CC!JPoNC': CL:`-'SIr;••A'CN(s) - I ALL WALLS AdD CEILINGS 2X4 WALL <'AR 2X4 WALL 2HR --- - - --- -- r' Ali f r a m I n hardware shown on these C T N LS N T.5. Y ROOM PRODUCT ORIENTATION AND FASTENING REQUIREMENTS. y plans, �ECTI ON CJ03 ALTER AT01 V S = FIRE RATED WALL TO BE CaI�E�E°WITH° HITS ALL WA115 AND CEILING$ USE I OCCUPANCY - This Room is to be Protected UL DESIGN IJO L IHR MOTEL TYPE"X SHEETRD K y, unless otherwise indicated, Is Simpson Strang-Tie. by a NFPA TO BE COVERED WITHo_ MOTEL /RESIDENTIAL R-1 C503.1 General UL DESIGN NO. U905 No substitutions are approved or authorized. TYPE OF CONSTRUCTION CHAPTER 6 p P = FIRE SEPARATION TYPE°X°SHEETPOCK �� # UL DESIGN N0.U301 - ( ) X4 WALL 2HR FIRE SEPARATION WALL ALL WALLS AND CEILINGS Alterations to any building or structure shall comply with the requirements of this section = NL°ESI NO.U3°I T°BFG°' WITH BETWEEN LOBBY z TYPE GROUP ALL WALLS AND CELINGS = 2X4 WALL 2HR TYPE"X'SHEETROCK FIRE SEPARATON WALL Due to the relationships of framing hardware to C503 and the code of the new construction. Alterations shall be such that the existing DBEDOVEREDWITH� _ °LBESI�N NO.U. 2°R0t V B HEIGHT AND FIRE AREA the other components of thenstruchure any lansframing building or structure Is not less conforming to the provisions of this code than the = AND ROOM #11 r hardware substitutions will render es p HEIGHT FIRE AREA null and void, and will result in the installer/contractor existing building or structure was prior to the alteration. Alterations to an existing - NOTE: (z_J a 4 HEIGHT. BUILDING. assuming responsibility for the design and building, buildingsystem or portion thereof shall conform to the provisions of this code _ 1 HR FIRE-RATED WALL CONSTRUCTION BETWEEN MOTEL NOTE PROVIDE FIRE CAULKING AT ALL HORIZONTAL AND VERTICAL PENETRATIONS HORIzoNTALSECTIOtJ THE VERTICAL DISTANCE FROM GRADE p y g g' y ROOMS AS PER THE 2020 BUILDING CODE OF NEW YORK IN FIREWALL AS PER THE 2020 FIRE CODE OF NEYl YORK STATE BEARING/NONBFARNc WALL RAnNc -2HR PLANE TO THE AVERAGE HEIGHT OF UNLIMITED AREA performance of the entire system, as those rovisions relate to new construction without re uinn the unaltered ortions of ❑NTS THE HIGHEST ROOF SURFACE 7000 SF. _ p requiring p NOTE: PROVIDE ROCKWOOL FIRE AND SOUNDPROOFING IN;ULATION IN ALL WALL 1. CONCRETE BLOCK' - Vorious Designs- Classilicolion D-2 2Hr =11'-6" AS PER CHAPTER 5 OF THE AS PER TABLE 506.2 g ( )' --- 2020 BUILDING CODE OF NEW YORK --- --- - -"'" - - - --" - -- --`- - STATE. the existing building or building system to comply with this code. Alterations shall not _ _ 2. MORTAR - Blocks laid in Lull bed of mortar,nom.$Iri thick, of not less Than 2-1/4 and not mope than 3-1/2 ports of clean sharp sand to COMMERCIAL CONSTRUCTION DETAILS create an unsafe or hazardous condition or overload existing building systems. 1 part Portland cement(proportioned by volume)and not more than 50 percent hydrated lime(by cement volume). Vertical joints staggered SILVER SANDS MOTEL FIRE SEPARATION BETWEEN STORAGE ROOM AND ROOM #14 3. PORTLAND CEMENT STUCCO OR GYPSUM PLASTER - If used, add 2 hr. to Clossificalion,Where combustible members are framed in Wall, TOTAL HEIGHT FROM RIDGE TO GRADE Max 15'-3" ALL CONSTRUCTION TO CONFORM TO ASCE STANDARD Plaster or Stucco must be applied on the face opposite framing to achieve o max. Ortssificatlon of 1-1/2 hr. Attached to concrete blocks item 1). (SEI/ASCE 7-22) EXCEPTIONS: The following alterations need not comply with the requirements for new 4. LOOSE MASONRY FILL-If oil core spaces are filled with loose dry expanded slog, expanded clay or shale(rotary kiln process), water repellant LUMBER SPECIES AND GRADE -- vermiculile masonry fill Insuglion. or silicone treated perlile loose fill insulitlon add 2 hr to Classificolion. ALL HOUSE FRAMING MATERIAL DOUGLAS FIR - LARCH #2 AND BETTER � construction, provided that the energy use of the building Is not increased: 8"E 5 8" FIRE SEPARATIONWALL 5. FOAMED PLASTIC °- (Optional - not shown) 1-1/2 in. thick max, 4 it Wide sheathing attached to cancrele blocks(Item 1). g"° A DESIGN NO.U301 ALL WALLS AND CEILINGS , 5 8" 2X6 WALL 2HR ALL EXT. DECK FRAMING MATERIAL CCA NO PINE #2 AND BETTER ALL WALLS AND CEILINGS "I , CI'OteX Cup - Type ThefmaX O BE COVERED WTH i° ALL WALLS AND CEILNGS TO BE COVERED WITH i' p p p e TO DE COVERED WTH TYPE"X"SHEETROCK r Bearing the UL Classification Marking 1. Storm windows installed over existing fenestration. TYPE TYPE"XSHEETROCK #, ACCESSIBILITY CONSTRUCTION / D E TA I S g ADA 3t Nick in Thick 2. Surfaced applied window film installed on existing single pane fenestration Bath I�bti °' Mineral Wool STORAGEiB°; 5i8 AREAS OF STRUCTURE ALL SPACES, AREAS, DETAILS, DIMENSIONS AND CONSTRUCTION DINER Room This Room is to be Protected ROOM #15 A ROOM #15 COMMERCIAL CONSTRUCTION , DETAILS NEW CRAWL SPACE NA assemblies reducing solar heat gain provided that the code does not by a NFPA 13SprinklerSystem ROOM #14 FIRE SFPAPADDNWALL NEW FINISHED BASEMENT NA TO CONFORM TO ICC/ANSI 2009 Al 1 7. 1 ' NTS NTS. STC E NTS. N.TS, UL DESIGN2XGWALL 2 u3D1 R.We02-22-23 ALL CONSTRUCTION TO CONFORM TO ASCE STANDARD EX. BASEMENT NA Rev. Dale o2 22-23 Rev Date 02-22-23 Rev Date 02 22-23 Rev-. Date 02-22-23 2X6 WAIL 2HR DINER 480SF require the glazing or fenestration to be replaced. TheRaomistobeProtected (SEI/ASCE 7-22) COFFEE SHOP STORAGE AREA 330 SF his Room is to be ALL WALLS AND CEILPJGS ihls Room is to be Protected This Room is to be Protected EX. SECOND FLOOR NA 3. Existin ceiling, wall or floor cavities exposed Burin construction, provided Protected by a NFPA ROO 14 ThisRooA13Sprs to elerSyte Prolected 1^ byaNFPA13RSpnnklerSyslem g P g p by a NFPA 13 Sprinkler System by a NFPA 13R Spr'mkle Sy tem TO BE COVERED WTH NEW SECOND FLOOR NA Note. 13 Sprinkler System N T S by a NFPA 13 Sprinkler System = TYPE'X"SHEETRDCK GENERAL NOTES- NEW BALCO Y NA that these cavities are filled with insulation. Rev°ate02-22-23 IRESIGNNO.U301L LOFT NA NFPA 13 Fire Sprinkler System is to be Installed throughout the rtire Diner and Coffee Shop in 2X6ILL WALL 2HR NOTE: ATTIC HOUSE a NA e ALL WALLS AND CEILINGS e 2X6 WALL 2HR 4. Construction where the existing roof, wall or floor cavity Is not exposed. A. URDE I NPNO°U30ALL NOTE: 1 HR FIRE-RATED WALL CONSTRUCTION BETWEEN MOTEL ROOMS AS PER THE 2020 BUILDING CODE OF NEW YORK PRE SEPARATION WALL ATTIC HOUSE b NA 1 TO BE COVERED WTH I' This Roorn is to be UL DESIGN NO.U301 NEW GARAGE ADDITION NA Accordance with the 2020 Fire Code of New York. Engineered Plans, of the System are to be TYPE SHFETROCK Protected by NFPA C6 2x6 WALL 2HR 8'CM'J. 2HR NOTE: PRMIDE FIRE CAULKING AT ALL HORIZONTAL AND VERTICAL PENETRATIONS IN FIREWALL AS PER THE 2020 FIRE CODE OF NEW YORK STATE ATTIC GARAGE o NA 5. Roof recovered. 13 Sprinkler System EX. UTILITY ROOM NA Submitted to the Town of Southold Building Department and The Town of Southold Fire Marshal NOTE: PR°ODE RDGKw°aL FIRE AND SOUNDPROOFING INSULATION IN ALL WALL EX. SCREENED PORCHES NA 6. Air barriers shall not be required and roof replacement EX. OUTDOOR SHOWER NA Prior to Installation. NOTE: EXISTING DECK NA - where the alterations or renovations to the building do not include 1 HR FIRE-RATED WALL CONSTRUCTION BETWEEN MOTEL NOTE: PROVIDE FIRE CAULKING AT ALL HORIZONTAL AND VERTICAL PENETRATIONS EX. COVERED ECK NA EX. COVERED FRONT PORCH NA alterations, renovations or repairs to the remainder of the building envelope. ROOMS AS PER THE 2020 BUILDING CODE OF NEW YORK IN FIREWALL AS PER THE 2020 FIRE CODE OF NEW YORK STATE COVERED ENTRANCE NA POOL HOUSE CABANA NA Fire Alarm System will be provided as per the 2020 New York State Building Code NOTE: PROVIDE ROCKWOOL FIRE AND SOUNDPROOFING INSULATION IN ALL WALL ACCESSORY STRUCTURE NA (a) WITHOUT STORAGE (b) WITH STORAGE 906.3 Size and Distribution of portable fire extinguisher shall be in accordance with Sections 906.1 through 906,3.4 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS Minimum Rated Single 2-Aa Extinq uisher Maximum 3000 Floor Area Per square feet Unit of A Maximum Floor Area For 11,250 Extinguisherb square feet Maximum Travel Distance 75 feet to Extinguisher WORK NOTES: b. NFPA 10 Appendix E-3-3 provides more details concerning application of the maximum floor area criteria. c. Two water-type extinguishers each with a 1-A rating shall be deemed the equivalent of one 2-A rated extinguisher for Light (Low) Hazard Occupancies. Combination LED Emergency Exit Sign and Emergency Lights provided with a Battery Backup are to be NOTE: Installed above the Exit Door on the North and South Side of the Lobby in accordance with ALL VENTS ARE TO BE LOCATED AT THE REAR OF THE HOUSE Section 1008 and Section 1013 of the 2020 Building Code of New York State ALL VENT PIPES ARE TO HAVE LEAD COATED COPPER SLEEVES / COVERS 3" THROUGH ROOF 3" THROUGH ROOF 3" THROUGH ROOF 3" THROUGH ROOF3" THROUGH ROOF 3" THROUGH ROOF 1 st FL_ooR II II II II II II II ROOF - - - z Fire Alarm System will be provided as per the 2020 New York State Building Code 3 3 3 3 3 3 3 3 DINERI DELI AREA 3 3 p m DINER COFFEE SHOPISTORAGE UNDER BAR LOBBY LOBBY UNir14 (3)COMPARTMENT UNiT12 BAR ADA S I N K U N D E R B A R BATHROOM ADA 0 UW22 11, UNIT21 11' UNIT20 11' UNIT19 11" UNIT18 11' UNIT17 11' UNIT16 11" UNR15 11, ESPRESSO 11, DRAINBOARD 11' BATHROOM 11' DRAIN � BATHROOM 2 2 2 2 2 2 2 2 MACHINE 2 2 2 BATHROOM BATHROOM BATHROOM BATHROOM BATHROOM BATHROOM BATHROOM U N D E R BAD COUNTER 11 ICE CHEST DRAIN DRAIN >� WARE PITCHER ELECTRIC COUNTER COUNTER > 2" 3" 2 3" 2 3" 2^ :3 2" 3" 2" 3" 2" 3" 2^ 3" WASHER RINSER HAND 2 33 HAND COOKING 3 3 HAN CE BAR / DUMP SI SINK SINK S E GLASS SI SINKS /SINK 0 MOP ,YLI, WASHER [T1�"/T7�Y'J/ Q SINK tY 1 st FLOOR - - 2 2 2 2 2 0 2 2'2» 23 ROJ ECT. 2,. 2,. 2.. 2.. 3.. 2.. 2,. 2., 2.. 2 2 2 2 2.. 3.. 2.. 3. 2 3 3 3" C.O.i 3 3. " 3,. 3„ I L ' 3" C.O, C.O, C.(D, C.O, C.O, C.O, C.O, C.O, C.O, C. C.O, C.O, C.OL 3,. 3,. 4.. 4" 4•• 4.. 4" F-A. VENT 6" 4" 4" 4•• 4.. 4., ABO�/E GRADE 4.. 4.. 4.. M- W EL FLOOR SLAB 3 3" NORTH WING / WEST END 4' 6•• 6-TO SCDHS APF>ROv/ED SEWER SYSTEMI WEST WING PLUMBING RISER DIAGRAM NTS PLUMBING RISER DIAGRAM (NTS) 4"F__1,B F.A. CVE: E6„ 1400 SILVERMERE ROAD ( ) 4" 4'C O GREENPORT, NY 11944 4.. 4•• 4., 4"TO SCDHS SCDHS APPF'O�/ED APPROVE0 APPROVED SCDHS GRE,4SE TRAP WE:RS SCTM # 1000-47-2-11 GREASE TRAP SEWER SYSTEM FLOOR SLAB 4" RAWING TITLE: FIRE WALL SEPARATION PLANS AND PLUMBING SCHEMATIC AS NOTED NOTES: JUN 13 2023 THESE PLANS ARE AN INSTRUMENT OF THE SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL WHOSE SEAL IS AFFIXED HERETO. INFRINGEMENTS WiLL BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW. CONTRACTORS SHALL VERIFY ALL u, ,. .,, „_::•-;;- FIELD CONDI110NS AND DIMENSIONS AND BE SOLEY RESPONSIBLE FOR FIELD FIT. THE DESIGN PROFFESSIONAL ASSUMES NO LIABILITY FOR OMMISIONS DUE TO UNKNOWN OR UNFORESEEN FIELD CONDITIONS AND OR ADDITIONS BASED UPON COMMENTS NOT FORMALLY ACKNOWLEDGED AS REVISION TO THESE PLANS. SEAL: DATE: JANUARY,25 2023 © COPYRIGHT 2023 KEHL DESIGN ASSOCIATES, LLC. PROJECT NO: ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED 1 141-2023 UNDER FEDERAL COPYRIGHT LAW. DRAWN BY: PLANS MAY NOT BE REPRODUCED WITHOUT �c�OF NEpfr BDK WRITTEN AUTHORIZATION. '�P J. Cp O� CHECKED BY: ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF G' �a�� Hooy RB KEHL DESIGN ASSOCIATES, LLC. THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE - SHEET UMBER: PLANS IS LICENSED EXCLUSIVELY TO THE BUYER, WITH WRITTEN t I - PROOF OF PURCHASE. _ G-002 84 V Acceptance of these drawings does not authorize the right to build without SION�\, the authorization of local governing agencies, such os Suffolk County Dept. DOB NUMBER: OF of Health Services, Town Building Departments, DEC, FEMA, etc. Verify all conditions, coups, and requirements With Such agencies prier to construction. 1) KEHL-DESIGN-ASSCTATE , uc k� a GENERAL NOTES: -- --- - - - - ---- ------- , - SAFETY NOTES: RESIDENTIAL RENOVATION &CONSTRUCTION s. SILVER SANDS MOTEL DIRE SEPARATION BETWEEN ROOM #12 ANO LOBBY CO NTR A CTO R N 0 T hE IS 1. Notes: 1. GENERAL: ALL WORK TO BE COMPLETED IN ACCORDANCE WITH THE TOWN OF SOUTHOLD, NEW YORK, 2020 BUILDING CODE OF Wood: NEW YORK, AND REGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. X,r-,/W�1- � T „••: nn Z Ei I: ,I GENERAL NOTES: 1. All studs to be SPF /f2 or better, and all other structural wood tc be Douglas Fir/Larch #2 or better. UL DESIGN NO. U3o5 1'-4' 1 -4" 2- FIRE SAFETY: Type X Sheetrocki 2. All structural wood shall be in accordance with the national design specifications for wood construction - latest edition. � � �" YP ;�- �I �, I � r; •, , f- r 1 I_ 1 ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE TOWN OF SOUTHOLD, Y REQUIREMENTS, K COUNTY, NEW YORK, 2020 RESIDENTIAL A. ALL BUILDING MATERIALS WHICH ARE STORED AT THE SITE OR ANY AREA OF THE BUILDING ARE TO BE STORED IN A - �_ / F CODE OF NEW YORK, FIRE DEPARTMENT RULES AND REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE 3. Nailing schedule shall be in accordance with the specified code. _ - I PRACTICES. B- LOCKED AREA. FIRE RATING 1HR a It 2• 4. Pre-manufactured trusses. FIRE SEPARATION WALL FIRE SEPARATION WALL STC 36 i J�� C. ALL MATERIALS TO BE STORED IN AN ORDEP.LY FASHION uL DESIGN N0.U301 n _ 11LHL DESIGN ASSOCIATES I�c BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF o. All trusses shall be "shaped" cs shown on architectural cross sections. UL DF9CII N N3nl SYSTEM THICKNESS 4?" - f BUILDINGS, OBTAIN ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, D. ALL FLAMMABLE MATERIALS TO BE KEPT TIGHTLY SEALED IN THEIR RESPECTIVE MANUFACTURER'S CONTAINERS. SUCH 2?ra-WAIL 2HR � 2X6 wAu 2HR O residential & commercial design • consulting b. Trusses shall bear o boco number and shop be manufactured by a registered manufacturer. 3Z Thick e Type X Sheetrock AND PAY ALL FEES REQUIRED BY THE GOVERNING BODY OF THE TOWN OF SOUTHOLD, NEW YORK, AGENCIES MATERIALS ARE TO BE KEPT AWAY FROM HEAT. 2x4 Wood Studs AL._WALLS AND CEILINGS Mineral Wool Wood 3• 5. Erect and brace trusses in accordance to truss plate institute recommendations. Insulaton MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT REQUIRED FOR PROPER CONSTRUCITON OF ANY PART OF THE WORK E. ALL FLAMMABLE MATERIALS To BE USED AND STORED IN ADEQUATELY VENTILATED SPACE. TO BE CO£RED N H�" ' ASSEMBLY OPTIONS. SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. 6. PI wood sheathin T PE"z'SHEETR�_r_Y NorEs: P0.Box 167 Y g F. ALL ELECTRICAL POWER TO BE SHUT OFF WHERE THERE ARE EXPOSED CONDUITS. - FIRE SrPAnAn°N WALL (, 5 4' a. All plywood shall be al accordance with the American re soil Association (APA) specifications. SILVER SANDY phone: l631)433-9084 THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH THE STIPULATIONS OF LOCAL AUTHORITIES, AND OWNER. b. Plywood sheathing shall be cortinuous over two or more spans with grain of face plys across supports G. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS. UL DESICN_ND U301 ROOM #12 8 8.. LOBBY c c r 5. corporation or equal. CONTRACTOR, AT ALL TIMES, TO ENSURE THERE IS NO NATURAL GAS LEAKAGE IN THE BUILDINGS, OR ANY FLAMMABLE 2X4 WALL 2HR NiS yiti GYPSUM BOARD. ONE LAYERS 5' THICK GYPSUM BOAP,D "TYPE X" STUDS AND INSULATION SIZES ARE MINIMUM UNl_S OTHFRW,E STATED IN DESI N Southold,NewYohk 11971 E-Moll: ssbn654Loptonl'ne.net THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED ROOM #12 CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL OR GAS TO BE USED DURING CONSTRUCTION. MOTEL 5 1/2" WOOD STUDS: 2X4 WOOD STUDS 16°OC. This Paam rs to be Prate ed FIRE SEPARAT:OA WALL ALL WALLS AND CCIIINES FOR THE MOST UP TO DATE INFORMATICIJ OR ASSEMBLY OPTI N$,PEFEP 10 THE REMOVAL TASKS. THE CONTRACTOR THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY Z All sills shall be pressure preservative treated (.4 PSF retention) S'YR /2 or better. HIS LOBBY by o NFPA t3 Sprinkler Sy tem ul DESIGN N0.U3Di INSULATION 3,1 MINERAL WOOL INSULATION IN CAVITY UL FIRE RESISTANCE DIRECTORY. OR DURING THE EXECUTION OF THE WORK. FIRE S E PARATI O TO COVERED wTu 8. Design values: 3. DUST CONTROL: XN T� 2X6 WAL. 2NR TYPE•X'SHEETROCK GYPSUM BOARD: ONE LAYERS �" THICK GYPSUM BOARD"TYPE X" �. Kehl Design Associates,LLC o formerly D A K Associates,LLC 6, oom is io be Protected a. Framing Lumber: DF (north) No. 2 or better by a NFPA t3 Spnnkler sy tem AALL WALL5 AND CEILINGS REFER TO THE UL FIRE RESISTANCE DIRECTORY FOR INFORMATION REGARDING THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES: A. DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM AND CONFINED TO THE IMMEDIATE CONSTRUCTION AREA. PLUMBING, ELECTRICALS, ETC. E = 1,600,000 PSI M BE COVERED WITH f' PRODUCT ORIENTATION AND FASTENING REOUIREMETTIS. OWNERSHIP & USE OF DOCUMENTS: V Fv = 95 PSI B. CONTRACTOR TO ISOLATE CONTRUCTION AREA FROM OCCUPIED BUILDING AREA BY MEANS OF TEMPORARY PARTITIONS OR FIRE SEPARATION WALL BETWEEN ROOM #12 TYPE'X'SHEETRDCK PLUMBING WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN THROUGH Fb - 825 PSI C. HEAVY DROP CLOTHS. ILL DESIGN 11,3D1 UL DESIGN NO. U301 THE DEPARTMENT OF BUILDINGS ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS. ALL WALLS AND CEILINGS 2X6 WALL 2HR N �_ �1'-4"-{ 1'-4"--{ B"Tyae X Sheetrock These drawings and specifications including the 8 9. Design values: DEBRIS, DIRT, AN DUST TO BE CLEANED UP AND CLEARED FROM THE BUILDING SITE PERIODICALLY TO AVOID EXCESSIVE iD BE COVERED NTH 5' _ AND D LOBBY ELECTRICAL WORK SHALL BE PERFORMED BE PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN a. Laminated Veneer Lumber (LVLj: ACCUMULATION. TYPE*X"SH'CETROCK FIRE SEPARATION WALL �"Tpe X Sheetrock ideas, design and arrangements represented uL DESIGN NO U301 F therein, are the property of KEHL DESIGN THROUGH THE BUREAU OF ELECTRICAL CONTROL ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS. E = 1,900,000 PSI = 8"CMU 2HRFIRE RATING: 2HR 9 Fv = 285 PSI Au wnus AND cNuwcs STC: NA ASSOCIATES, LLC. No part thereof shall be Fb = 2600 PSI 4. NOISE AFTER HOURS: THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPARING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE O PE COV RED W H r _ SYSTEM THICKNESS 6" copied, disclosed t0 others Or used in connection 10 DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB. A. CONSTRUCTION OPERATIONS WILL BE CONFINED TO NORMAL WORKING HOURS: 8AM TO 6PM, MONDAY TO FRIDAY, PE"X"SHEEIROCK"X"SHEETROCK �5, with any Work Or project other than for WhlCfl ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED. B. EXCEPT LEGAL HOLIDAYS. 32"ThLk -2x4 Wood Studs B Type X Sheetrock they have been prepared without written consent. NOTE: NOTE: PROVIDE FIRE CAULKING AT ALL HORIZONTAL ;rM VERTICAL PENETRATIONS Miners want 1"type X Sheetrock CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM ALL AFFECTED PARTIES TO WORK OTHER THAN REGULAR HOURS. ASSEMBLY OPTIONS, Insulation 16 oc. ALL DIMENSIONS ARE ESTABLISHED FROM THE FINISH LEVEL OF THE FIRST FLOOR. VARIATIONS TO THE HEIGHT OF THE FINISH LEVEL I HR FIRE-RATED WALL CONSTRUCTION BETWEEN MOTEL IN FIREWALL AS PER THE 2020 FIRE CODE OF IL'N YORK STATE OF THE FIRST FLOOR ARE TO BE REVIEWED FOR APPROVAL BY THE OWNER AND KEHL DESIGN ASSOCIATES LLC. NO CONSTRUCTION 5 CONSTRUCTION OPERATIONS WILL NOT INVOLVE INTERRUPTION OF HEATING, WATER, OR ELECTRICAL SERVICES TO THE OWNER. ROOMS AS PER THE 2020 BUILDING CODE OE NEA YORK NOTES: REV• WILL BE ALLOWED TO COMMENCE UNTIL THIS HEIGHT IS APPROVED. CONSTRUCTION WORK WILL BE CONFINED TO THE WORK ISSUED, AND WILL NOT CREATE DUST, DIRT, OR OTHER SUCH NOTE: PROVIDE ROCKWOOL FIRE AND SOUNDPROOFING INSULATION IN ALL WALL GYPSUM BOARD: two LAYERS e THICK GYPSUM BOARD"TYPE )" 12' INCONVENIENCES TO THE OTHER NEIGHHBORS. WOOD STUDS 2X4 WOOD STUDS 16" OC. STUDS AND INSULATION SIZES ARE MINIMUM UNLESS OTHERWISE STATED IN DESIGN. JANUARY 22, 2023 THE CONTRACTOR IN COORDINATING THE WORK WILL REPORT ANY DISCREPANCIES TO THE ENGINEER'S ATTENTION FOR IMMEDIATE RESOLUTION. 6 SPECIAL SAFETY NOTES INSULATION: 32 MINERAL WOOL INSULATION IN CAVITY FOR THE MOST UP TO DATE INFORMATION OR ASSEMBLY OPTIONS REFER 10 THE JANUARY 25, 2023 13. GYPSUM BOARD: TWO LAYERS N" THICK GYPSUM BOARD"TYPE X" UL FIRE RESISTANCE DIRECTORY. FEBRUARY 22, 2023 THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ALL UTILITY LINES WITH THIS AND RELATED SITE WORK, AND ALL CONTRACTORS AND THEIR REPRESENTATIVES WORKING ON THIS PROJECT SHALL AT ALL TIMES PRIOR AND DURING THE COURSE HE WILL BE RESPONSIBLE FOR ALL DISCONNECTIONS, RECONNECTIONS, AND STARTUPS. OF THEIR ACTIVITY BE RESPONSIBLE FOR THE SAFETY OF THEIR EMPLOYEES AS WELL AS OTHERS AND IN THE CARE OF THE APRIL 20, 2023 14. PROPERTY, EACH AS REPRESENTATIVES OF THEIR EMPLOYEES SHALL ASCERTAIN THAT THE CONDITIONS UNDER WHICH THEY WILL BE REFER TO THE UL FIRE RESISTANCE DIRECTORY FOR INFORMATION REGARDING JUNE 11, 2023 THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ELECTRICAL, PLUMBING, AND HVAC EQUIPMENT WITH REQUIRED TO ACCOMPLISH THEIR WORK ARE SAFE WITHIN GOOD SAFETY PRACTICES AND MEET ALL CONCERNED REGULATIONS OF PRODUCT ORIENTATION AND FASTENING REOUIRCMrIJTS JUNE 13, 2023 ARCHITECTURAL FEATURES AND STRUCTURE. ANY CONFLICTS WILL BE BROUGHT TO THE ENGINEER'S ATTENTION FOR IMMEDIATE THE OCCUPATIONAL SAFETY AND HAZARD ACT OR OTHER GOVERNING REGULATIONS. THE BEGINNING OF WORK BY A CONTRACTOR SILVER SANDS MOTEL FIRE SEPARATION BETWEEN LOBBY AND ROOD #11 _ RESOLUTION. SHALL INDICATE SATISFACTION CONCERNING SAFETY AND FULL RESPONSIBILITY FOR ACCIDENTS OR DAMAGE. IF UNSATISFIED, THE CONTRACTOR SHALL INDICATE WHATEVER ACTION NECESSARY, OR RENDER SAFETY CONDITIONS FOR LIFE AND PROPERTY AS ARE UL DESIGN NO. U3O1 1 4 1 4 e'Type X Sheetrock RELATED TO HIS ACTIVITY. IF THE WORK OF OTHER PARTIES OUTSIDE OF THE ORGANIZATION IS UPON INSPECTION FOUND AT ANY N 5,Type X Sheetrock TIME TO BE UNSAFE, HE SHOULD STOP WORK IMMEDIATELY AND NOTIFY THE GENERAL CONTRACTOR, KEHL DESIGN ASSOCIATES LLC, OR OWNER. THE BEGINNING OF WORK SHALL INDICATE SATISFACTION WITH CONDITIONS AND ACCEPTANCE OF THESE REQUIREMENTS. ALTERATION LEVEL #3 AS PER THE 2020 EXISTING BUILDING CODE OF NEW YORK = FIRE RATING: 2HR CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA = O SIC 42 GROUND WIN -_ SYSTEM THICKNESS 8" WALL FIRE PAP^!G FIRE SEPARATION WALL D SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE SHIELD ALL WAILS AND CEILINGS - UL OE9GN NO U3DI UL DESIGN N0.U301 "CLIMATE ZONE U5,'- Thlrk �'Type X Sheetrock SNOWDESIGN FROST LINE DESIGN UNDERLAY- FLOOD W ND EXPOSURE TO BETO COVE_�ED NTH)NTH) = FIRE SEPARATION WALL ALL WALLS AND CEILINGS 2X4 WALL 2HR 2X4 WALL 2HR ASSEMBLY OPTIONS Minral Wool 2x6 Woad Studs LOAD SPEED m h CATEGORY WEATHERING DEPTH TERMITE DECAY TEMP. MENT REQUIRED HAZARDS CATEGORY RESIDENTIAL COMMERCIAL TYPE'X'SHEETROCK = I.A.DESIGN NO U301 TD BE COVfP,ED NTH i"_ _ Insulation 16'ac. �'Type X Sheetrock 25 Ibs/sgft 130 (mph) C SEVERE 3'-p" MODERATE TO HEAVY SLIGHT TO MODERATE 11 degrees YES igg4/lggg C 4A 4A 2X4 WALL 2HR TYPE'X"SHEETROCKSHEE ROCK UTILTY NOTES: ROOM GYPSUM BOARD. TWO LAYERS 5" THICK GYPSUM BOARD"TYPE X" 2018 International Energy Conservation Code IECC LOBBY " g" WOOD STUDS: 2X6 WOOD STUDS 1fi° OC STUDS AND INSULATION SIZES ARE MINIMUM UNLESS OTHERWSE STATED IN DESIGN DESIGN CRITERIA NTS INSULATION 52 MINERAL WOOL INSULATION IN CAVITY FOR THE MOST UP TO DATE INFORMATION OR ASSEMBLY OPTIONS REFER 10 THE N 0 SUBSTITUTIONS _ _ 3 1/2" 3 1/2 ROOM #11 GYPSUM BOARD TWO LAYERS�" THICK GYPSUM BOARD"TYPE X" UL FIRE RESISTANCE DIRECTORY. PRESCRIPTIVE DESIGN - N T.S I" SILVER SANDS WALL FIRE RAT U FIPE SEPARATION WALL This Voom is to be Protected LOBBY = =_ ROOM #11 UL DESIGN NO U3n1 UTILTY UL DESIGN NO U30t by a NFPA IJR Sprinkler System REFER TO THE UL FIRE RESISTANCE DIRECTORY FOR INFORMATION REGARDING USES(s)USE AND OCCUPANCY CLASSIFICCUP N C SECTION C503 ALTERATIONS N.T.S. N.T.S. ALL WALLS AND CEILIN S 2X4 WALL 2HR ROOM 2X4 WALL 2HR PRODUCT ORIENTATION AND FASTENING DIRECTORY REQUIR FOR IN All framing hardware shown on these plans, USE OCCUPANCY unless otherwise indicated, is Simpson Strong-Tie. °ERA�DWALL This Room is to pr Protected MOTEL NTS ALL WAYS AND CEILINGS S. MOTEL / RESIDENTIAL R-1 r UL DESIGN NO U305 IHR TYPE"N SHEETROCK TYPE OF CONSTRUCTION (CHAPTER 6) No substitutions are approved or 3 u t h o r l z e d. C503.1 General _ = by a NFPA 13P Sprinkler System TO BE cDVEREo WITN o_ FIRE SEPARATION YPE`X"SHEETRDG"EETP°GK ur DESIGN No. ugo5 _°� 1- -- 1 -- 1 V 4' l'-4" UL DESIGN N0.U301 = � Alterations to any building or structure shall comply with the requirements of this section 2X4 WALL 2HR - FIRESEPARATIGNWALL A,�WAL z TYPE GROUP _ UL DESIGN NO,UMI TO BE COVERED NTH Y Due t o the relationships o f framing hardware t o ALL WALLS AND CEILINGS = 2X4 WALL 2HR TYPE'X SHEETPDCK BETWEEN LO B LOBBY FIRE SEPARATION WALL B C503 and the code of the new construction. Alterations shall be such that the existing y = DLDESIGII VD D3D, TD BE COVERED�TH o the other components of the structure, any framing . . TYPE-X- _ 8'CMU 2HR nn nn buildingor structure is not less conforming to the provisions of this code than the AND ROOM #11 HEIGHT AND FIRE AREA hardware substitutions will render these plans g p _ - Ak HEIGHT FIRE AREA null and void, and will result In the installer/contractor existing building or structure was prior to the alteration. Alterations to an existing _ _ NOTE: l 4 4 HEIGHT. BUILDING. assuming responsibility o n s i b i I i t for the design s i n and = 1 HR FIRE-RATED WALL CONSTRUCTION BETWEEN MOTEL NOTE: PROVIDE FIRE CAULKING AT ALL HORIZONTAL AN11 VERTICAL PENETRATIONS HORIZONTAL SECTION THE VERTICAL DISTANCE FROM GRADE p y g building, building system or portion thereof shall conform to the provisions of this code PLANE TO THE AVERAGE HEIGHT OF ROOMS AS PER THE 2020 BUILDING CODE OF NEW YORK IN FIREWALL AS PER THE 2020 FIRE CODE OF NrW YDRK STATE THE HIGHEST ROOF SURFACE UNLIMITED AREA performance of the entire system. ' 1 BEARING NONBEARING WALL RATING -2HR 2020 B" DI PER CHAPTER 5 OF THE �DaD SF. as those provisions relate to new construction without requiring the unaltered portions of NOTE: PROVIDE RocKwooL FIRE AND SOUNDPROOFING IFsuLATION IN ALL WALL ,. CONCRETE BLOCK various Designs - Gassifiaatian D-2 c2Hr). - 2020 BUILDING CODE OF NEW YORK AS PER TABLE 506.2 STATE. the existing building or building system to comply with this code. Alterations shall not -- ___ _ _ 1 MORTAR -Blocks Laid In full bed of mortar, nom.a in. thiLk, 01 not less than 2-1/4 and not more than 3-1/2 parts of cle in sharp sand to 1 part Portland cement(proportioned by volume)and not more than 50 percent hydrated lime(by cement Volume). Vertical joints staggered. COMMERCIAL CONSTRUCTION � DETAILS- create an unsafe or hazardous condition or overload existing building systems. SILVER SANDS MOTEL FIRE SEPARATION BETWEEN ST ORAGE ORAG E ROOD AND ROOM #14 3. PORTLAND CEMENT STUCCO OR GYPSUM PLASTER - If used,odd 21 hr. to Classification,Where combustible members are framed in woll, TOTAL HEIGHT FROM RIDGE TO GRADE Max 15'-3" PoSief Of$taCDa mast be appl�d On the ToCe Opposite framing i0 achieve a max, GIaSSIfICOtIOn of i-1/2 hr. AitaCfled t0 concrete bI0Ck5(Item 1). LUMBER SPECIES AND GRADE ALL CONSTRUCTION TO CONFORM TO ASCE STANDARD - E X C E P TI ON S: The f a I I a w i n a l t e ra t i o n S need not a a m I\/ with the requirements for new 4.LOOSE MASONRY FILL- If oil core spaces are filled with loose dry exponded slog, eXponded cloy or shale(rotary kiln process), water repellant (S E I/ASCE 7-22) g comply vermiculite masonryfill insulation. or Ohre treated erlite loose fill insulation oLd 2 hr to Classification. construction, 11 P ALL HOUSE FRAMING MATERIAL DOUGLAS FIR - LARCH #2 AND BETTER CGnStrUCtlOn, provided that the energy use of the building is not increased. FIRE SEPARATIrd1WALL r,_ 8" S 8' S. FOAMED PLASTIC (Optional - not shown) 1-i/2 in. thick mnx, 4 It wide sheathing attached to concrete blocks(Item 1) ALL EXT. DECK FRAMING MATERIAL CCA NC PINE #2 AND BETTER g" �; UL DESIGN NO 113D1 AI�WALLS AND CEILINGS All WALLS AND CEILINGS 5 8" 2X6 WALL 2HR O BE C01 RED NTH B" ALL WALLS AND CEILINGS TO DE COVERED NM Celotex Corp. - Type Thermaz ACCESSIBILITY CONSTRUCT 0 f� D ETA �S 1 Storm windows installed over existing fenestration. PE"X"SHEERFK TO BECDVEREDWTH- TYPE"X"SHEEIROCKLIL] * BearingtheULClassificolionMarking TYPE"X"SHEETROCK'X"SHEETROCK 2• Surfaced applied window film installed on existing single pane fenestration ADA 3j two 3, nW p P 9 g P Bath Mmcrnl wool Pine ul Woo STO RAG EiB:;, Si8 AREAS OF STRUCTURE ALL SPACES, AREAS, DETAILS, DIMENSIONS AND CONSTRUCTION DINER Irisulalion Mslation NEW CRAWL SPACE NA ROOM this Room is to be Protected ROOM #14 ROOM #15 NEW FINISHED BASEMENT NA � assemblies reducing solar heat gain, provided that the code does not N.TS NTS. byaNFPA13SpnnklerSystem ROOM #15 .' PIPE � COMMERCI4�L CONSTRUCTION / DETAIL_S TO CONFORM TO ICC/ANSI 2009 All 17. 1 NTS. NT.S UL Re.Dole0222-23 ALL CONSTRUCTION TO CONFORM TO ASCE STANDARD EX. BASEMENT NA Rev. Date 02-22-23 N I` DINER 480SF require the glazing or fenestration to be replaced. Rev Date02-22-23 STORA_ Rev.Date02-22-23 Rev. Date02-22-23 2X6 WALL 2HR COFFEE SHOP STORAGE AREA 330 SF ThsRoomisfo6e (SET/ASCE 7-22) pp �/ p p I I construction, This Room is to be Protected This Room is to be Protected � ALL WALLS AND CEILINGS pis Roan is 10 be Protected EX. SECOND FLOOR NA J. L x s t i n g a i n(D w a l l a r f I a o r c a V t I l S 1 x p a S e d d u r i n g provided b o NFPA 13 Sprinkler S tem Protected by a NFPA R® This Room is to be Prate ted ly o NFPA 13R SDriAler S tem Y P n b a NFPA 13R S rmkl OBE COVERED NTH NEW SECOND FLOOR NA Note. 13 Spmkler System y p er System by o NFPA 13 Spr'mkler System Y y 5 TYPE"X'SHEETRDCK GENERAL Ni NEW BALCONY NA that these cavities are filled with insulation. Rev Dale02-22-23 - FIRE SEPARATION WALL LOFT NA NFPA 13 Fire Sprinkler System is to be Installed throughout the entire Diner and Coffee Shop in UL DESIGN NO U301 ATTIC HOUSE a NA 4. Construction where the existing roof, wall or floor cavity LS not exposed. ALfWIL11 CEILINGS FIPE SEPARATION WALL2X6 WALL 2HR NOTE: 1 HR FIRE-RATED WALL CONSTRUCTION BETWEEN MOTEL ROOMS AS PER THE 2020 BUILDING CODE OF NEW YORK ATTIC HOUSE b NA Accordance with the 2020 Fire Code of New York. Engineered Plans of the System are to be TONHo FIRE SEPARATIONWALI NEW GARAGE ADDITION NA �" s Room s to be ILLDESIG ORU301 UL DESIGN NO.U301 ATTIC GARAGE o NA 5. Roof recovered. TYROCK Protected by a NFPA (qlXl 8"CMU 2HR NOTE. PROVIDE FlRE CAULKING AT ALL HORIZONTAL AND VERiICAI PENETRATIONS IN FIREWALL AS PER THE 2020 FIRE CODE OF NEW YORK STATE EX. UTILITY ROOM NA Submitted to the Town of Southold Building Department and The Town of Southold Fire Marshal 13Sprinkler5ystem EX. SCREENED PORCHES NA 6. Air barriers shall not be required and roof replacement NOTE: PROVIDE ROCKWOOL FIRE AND SOUNDPROOFING INSULATION IN ALL WALL EX. OUTDOOR SHOWER NA Prior to Installation. EXISTING DECK NA where the alterations or renovations to the building do not include NOTE: - NEW DECK NA 1 HR FIRE-RATED WALL CON TRUCTION BETWEEN MOTEL NOTE: PROVIDE FIRE CAULKING AT ALL HORIZONTAL AND VERTICAL PENETRATIONS EX. COVERED DECK NA EX. COVERED FRONT PORCH NA alterations renovations or repairs to the remainder of the building envelope. ROOMS AS PER THE 2020 BUILDING CODE of NEW YORK IN FIREWALL AS PER THE 2020 FIRE CODE OF NEW YORK STATE COVERED ENTRANCE NA 1 POOL HOUSE CABANA NA Fire Alarm System will be provided as per the 2020 New York State Building Code NOTE: PROVIDE ROCKWOOL FIRE AND SOUNDPROOFING INSULATION IN ALL WALL ACCESSORY STRUCTURE NA (a) WITHOUT STORAGE (b) WITH STORAGE 906.3 Size and Distribution of portable fire extinguisher shall be in accordance with Sections 906.1 through 906.3.4 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS Minimum a Rated Single 2-A Extinguisher Maximum 3000 Floor Area Per square feet Unit of A Maximum Floor Area For 11,250 Extinguisherb square feet Maximum Travel Distance 75 feet to Extinguisher WORK NOTES: b. NFPA 10 Appendix E-3-3 provides more details concerning application of the maximum floor area criteria. c. Two water-type extinguishers each with a 1-A rating shall be deemed the equivalent of one 2-A rated extinguisher for Light (Low) Hazard Occupancies. NOTE: Combination LED Emergency Exit Sign and Emergency Lights provided with a Battery Backup are to be ALL VENTS ARE TO BE LOCATED AT THE REAR OF THE HOUSE Installed above the Exit Door on the North and South Side of the Lobby in accordance with ALL VENT PIPES ARE TO HAVE LEAD COATED COPPER SLEEVES / COVERS Section 1008 and Section 1013 of the 2020 Building Code of New York State 3" THROUGH ROOF 3" THROUGH ROOF 3 THROUGH ROOF 3" THROUGH ROOF3" THROUGH ROOF 3" THROUGH ROOF 1 st FLooR II II II II ROOF 3 3" 3" 3" 3" 3" 3'" 3" z Fire Alarm System will be provided as per the 2020 New York State Building Code DINERI DELI AREA 3 3 a J m UNDERBAR LOBBY DINER COFFEE SHOP 1 STORAGE 3 C o M P A R T M E N T LOBBY UW22 11" UNIT21 11' UNIT i' r p p �„ � BATHROOM ATHR < > UNIT BAR 0 ADA��� SINK u N D E R B A R BATHROOM �'A 0 2 2 12 UNIT 12 UNIT18 IT UNIT11 12 UNIT16 12 UNiT15 12 MSAPRESE o 1�r DRAINBOARD 11' BATHROOM 11' DRAIN BATHROOM BATHROOM BATHROOM BATHROOM BATHROOM BATHROOM BATHROOM BATHROOM U N D E R BA? 2 2 COUNTER J 1, ICE CHEST DRAIN Q WARE PITCHER -_2.. 3 2 3 2" 3 2" 3' 2" 3" 2" 3" 3" HAND 12 ELECTRIC DRAIN COUNTER "- 2" 2" 3' WASHER RINSER 3" HAND 3" 3" > SINK SINK SINK COOKING COUNTER HAN ICE BAR /DUMP / SUITE SINK SINKS Z l.IU1, GLASS ` SINK 1 st FLOOR MOP WASHER SINK � T�-7 t K „ „ rT 2 2 •• 2 .. 2 3.. 2 3.. 2.. 3.. 2.. 2.. 2 2 2 2 2 r, L 2„ 3 2 C•o. 2 2 2 2 ROJECI: 3" .. 3.. C.O.r 3' 3. c.o, C.C), c.o, c.o, c.o, C. c.o, c.o, c-o, c.o., c.o, \ C.C) 4„ 4•• 4„ 3.. 3., SILVER 4.. 4 4•' 4„ 4,. 4., ABOVE r�AUE 6., -4 4.. 4,. FLOOR SLAB 3„ - 4'C.O 3,. MVIEL NORTH WING / WEST END 4.. g" C,­TO SCDHS APPROVED WEST WING PLUMBING RISER DIAGRAM (NTS) PLUMBING RISER DIAGRAM (NTS) SEWER SYSTEM 4" F.A. VENT 6" 1400 SILVERIIERE ROAD C.O.i ABO\/E ,_BADE GREENPORT, NY 11944 4•' 4.. 4.. 4'C.C 4" '- 4' 4' 4"TO 53CDHS SCDHS 6"TO SCDHS FLOOR APP H7 TR APPROVED APPROVED SCTM # 1000-47-2-11 LA B GREA�E TRAP GREASE TRAP SEWER SYSTEM 4' RAWING TITLE: FIRE WALL SEPARATION PLANS AND PLUMBING SCHEMATIC AS NOTED N01 ES: JUN 1 3 20 THESE PLANS ARE AN INSTRUMENT OF THE SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL WHOSE SEAL IS AFFIXED HERETO. INFRINGEMENTS 'MLL BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW. CONTRACTORS SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS AND BE SOLEY RESPONSIBLE FOR FIELD FIT. THE DESIGN PROFFESSIONAL ASSUMES NO LIABILITY FOR OMMISIONS DUE TO UNKNOWN OR UNFORESEEN FIELD CONDI110NS APJD OR ADDITIONS BASED UPON COMMENTS NOT FORMALLY ACKNOWLEDGED AS REVISION TO THESE PLANS. SEAL: DATE: JANUARY,25 2023 © COPYRIGHT 2023 KEHL DESIGN ASSOCIATES, LLC. PROJECT NO: ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED 1 141-2023 UNDER FEDERAL COPYRIGHT LAW. OF N DRAWN BY: PLANS MAY NOT BE REPRODUCED WITHOUT c��p` it WRITTEN AUTHORIZATION. o�,N �• CD fp BDK ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF * �( 0 �� CHECKED BY: abr *J y RB KEHL DESIGN ASSOCIATES, LLC. THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE rnT NUMBER: PLANS IS LICENSED EXCLUSIVELY TO THE BUYER, WITH WRITTEN PROOF OF PURCHASE. �'O 05168 ((�_�� G-0 02 �vv SSiON a�-�' Acceptance of these drawings does not authorize the right to build without the authorization of local governing agencies, such as Suffolk County Dept. DOB NUMBER: OF of Health Services, Town Building Departments, DEC, FEMA, etc. Verify all conditions, codes, and requirements with such agencies prior to ' FCO construction. KEMDESTGN•ASSOCIATES, uc . r�n l.� AMEN RT�WT - 3 O_ : m L a� U C m 0 O r U O 8'-9Y4" a a e a y O —2, 2-,----------------------- °o°o°o °o°o° d • N° ° ° ° I %\ 0 0 OPENREF (STORAGE o w- 2 -7HAND SINK >ACCESS r., o a m a II II HAS II I I I II�II CII F;. o REF REF REF LJ II I HAND SINK \1 / ACCESS ' 36 East 31st Street, 6th Floor 3 �\ New York, New Yol'rk 10016 I OVEN Tel: (212)244-0008 r t --- Fax: (212)244-0057 email: jkouveras i samtell.com STORAIE _ I I I REMOVABLE �I I I WED ADA HEIGHT RELEASE I �\ mc�aeo I I I EXTENSION 1 0 MEP SUBMISSION 1 2-23-2022 AO --- ---- — _----� 1 1 MEP SUBMISSION 12-28-2022 AO 12 MEP SUBMISSION W -03-2023 AO 13 MEP SUBMISSION 01 -05-2023 AO Ilj "el jll — 4 OYSTER BAR CONCEPT G71 - 'I r -2023 DE IIL---JII 15 OYSTER BAR REVISIONS 01 -25-2023 KK L===JJ 16 OYSTER BAR REVISIONS 01 -31 -2023 DE 1 i 177STER/1-OBBY BAR MEP 02-10-2023 DE 18 BACKGROUND UPDATE 02-24-2023 DE REF 19 DINETTE MEP SCHEDULES 02-27-2023 DE 2 DOH SUBMITTAL 03-02-2023 DE / 21 DOH SUBMITTAL UPDATE 03-09-2023 DE 22 MEP DOCUMENTATION 03-10-2023 DE 2 CLARIFICATIONS 03-16-2023 DE 24 DOH SUBMITTAL UPDATE 03-27-2023 DE � I 25 DOH UPDATE, PART 2 03-31 -2023 DE Tu I 2E MEP UPDATE 04-05-2023 DE I 3,-6„ BOATHOUSE UPDATE 04-21 —2023 DE 28 DINETTE UPDATE 04-23-2023 DE ——————- 29 BOATHOUSE UPDATE 06-09-2023 DE I------ 3C REV.BOATHOUSE 08-29-2023 EA OPEN I ____ 31 SK3.0 09-12-2023 KK STORAGE i I PROJECT I 3' OPEN I p"","'� 0 STORAGE I t REF �:� G/W rDUMP, - I "" S �"'� ---- -- —� no pi ABBREVIATIONS HW HOT WATER 140 JB JUNCTION Box CW COLD WATER SR SINGLE RECEPTACLE DW DIRECT WASTE DR DUPLEX RECEPTACLE £ (NDIRECT WASTE CID CORD FFD LOOR DRAIN OR DRAIN SW SWITCH SCALE PLUG ' SCALE FFD F N w y0 HP HORSE POWER FS FLOOR SINK 22 x 34 = 1 -0 @ 1 1 x 1 7 3 G GAS KW KILOWATTS b -1 -O BTU BRITISH THERMAL UNIT V VOLTAGE P F� S STEAM GU GENERAL USE DRAWING 1�S CR CONDENSATE RETURN RECEP. RECEPTACLE = AFF ABOVE FINISHED FLOOR 0 LP LIQUID PROPANE EOF ELECTRICAL OUTLET IN FLOOR DINETTE SEATING SKETCH Q CFM CUBIC FEET PER MINUTE BTC BRANCH TO CONNECT J 4w SP STATIC PRESSURE DFA DOWN FROM ABOVE PSI POUNDS PER SQUARE INCH BOA Q 0570°�� �`�� HVAC HEATING/VENTILATING CONTRACTOR COW OUT OF WALL i ID INSIDE DIAMETER !� EC ELECTRICAL CONTRACTOR IPS IRON PIPE SIZE ' "Es S1O KEC KITCHEN EQUIPMENT CONTRACTOR OD OUTSIDE DIAMETER GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MINUTE PC PLUMBING CONTRACTOR FP FIRE PULL BOX DRAWING N U M B E R NIC NOT IN CONTRACT SO SMOKE DETECTOR I WC WATER COLUMN AV AUDIO VISUAL DEVICE CWS COLD WATER SUPPLY NG NATURAL GAS CWR COLD ATER RETUR {F' r o t U N a l U CL _ ...,.,.-1 1 - 3..Jx..r.r.W,s..r;ati .° •"r _ :Aq r R i , - i JA.. �'� {pap i 6 f 1 _y yE - A h q r -1 ny C A' 1 .7 3 , • k v�: L i a r ..y O x, v J F 1 s :iz _..., .. s "`«ir ,: ''G ..wc..u..:,r.....:::. .a'• .•i.€.: - '`,.ai ,''i...il a-. .. ,.. ... AP D AS NOT , DATE: B.P. E FEE: BY: &( a NO''IFY BUIL IN DEPARTMENT AT 765-1802 8 0 4 PM FOR THE COMPLY WITH ALL CODES OF , FOLLOWING I s cTloNs: NEW YORK STATE & TOWN CODES . ° 1. FOUNDATION TWO REQUIRED AS REQUIRED AND CONDITIONS OF 14 0 0 1 L M E E A u FOR POURED ONCRETE t, .� 2. POUGH • FRAMING & PLUMBING Q 3. INSULATIO 4. 1'VAL - C NS RUCTION MUST - 'N LA INGBOARDFj BE COMPL TE FOR C.O. ' o S +f �JN---TRUSTEES .. ALL CONSTR GTI IN SHALL MEET THE / --- REQUIREME S F THE CODES OF NEW RK STATE. N RESPONSIBLE FOR DESIGN OR ON TRUCTION ERRORS. CL T[[l• 3 O DINETTE LOBBY BAR OCCUPANC R LOCATION LOCATIONX USE IS UNL N UL cz SHEET INDEX. WITHOUT C R IFICATEy7.3 '--1 OF OCCUPY 1 i' \z,,• ... Y„� ;�i1_ 4 ✓a, r, '' .�.d;swt I �`. i al. 'a r { •. ...,,.,,.:. `, CAS U) 1 C J J ({ o FS 0 COVER SHEET tl • F' FS IND 1 .0 STANDARD INSTALLATION DETAILS East 31 st Street, 6th` 1 , E Floor New York, New York 10016 U.1 I ` " .�.. t41 J ' 9 t'...'• i tfk ,.,. ��'Nf• u L �: Tel: (�12)244 0008 FIP IE�SPE �, ,lr a J n f:J. .r f ., 3 o ri. �� ' !' Fax: ,T 0{�. FS 1 .0 DINETTE EQUIPMENT PLAN '4,F;fiTf. �a ' u, i i (�12)244-oos� I-�,�.�UIRED E ORE pE? FS 1 . 1 DINETTE EQUIPMENT SCHEDULE `�' ",; 3• i' email: jkouveras@samtell.com EIIO Ii FS E1 0 DINETTE ELECTRICAL PLAN 1 „ zc'. - I - -- RELEASE_ FS E1 . 1 DINETTE ELECTRICAL SCHEDULE I ' ! �' t# I 8 REV. Co CEPT, . I IN DESIGN 12-12-2022 DE .,'ter. /.�' _„-, ,!( 1?°� �y '! ' :' li 9 DESIGN DEVELOPMENT 12-13-2022 DE FS P1 .0 DINETTE PLUMBING PLAN ,-, 10MEP SUBMISSION 12-23-2022 AO i ` Y{ 1 1 MEP SUBMISSION FS P1 . 1 DINETTE PLUMBING SCHEDULE i . : SS ON 12-28-2022 AO �,Ir,�;; _. �`=�', ro 12 MEP SUBMISSION 01-03-2023 AO FS P1 .2 DINETTE FLOOR DRAIN/SINK PLAN 13MEP SUBMISSION 01-05-2023 AO x A n e' i r, ! p - - e (jy h z' I 01 19 l�/ "flT'F' TI I ` '`�6 ' ` gip. u.,`r. �, -- f"J ,� F;,1,aP�r �., ,! c-' ;�; I ''' 'i'S 'S 't 1:ti i �� 15OYSTER BAR 14 OYSTER BAR C -2023 DE PLU c Ord o►\FS SC1 .0 DINETTE SPECIAL CONDITIONS PLAN i - z " f.f 1L._ � � ! _ REVISIONS 01-25 2023 KK TENT BEFOP ' i ---- __ - ,f' ,�` ;r orf ='l ` ,{> : , I .: O+' ,LEAQ O I I 9.8 -,; - I y r. , 16 OYSTER BAR REVISIONS 01-31-2023 DE C�RTI�ICA E F OCCUPAM ?S M 1 .0 DINETTE MECHANICAL PLAN I r'I ,0.9 � i - - i,:-n .� �' ' � � I � ! - - � ` �;' T i 17 OYSTER LOBBY BAR MEP 02 10 2023 DE -- --` %71 a 1°" � � { I ; 18 BACKGROUND UPDATE 02-24-2023 DE SOLDER S .D 1N WATER SUPPLY Y EM CANNOT u._ -_ `,• a - I I. I ,.r i>t' -�/ { 19DINETTE MEP SCHEDULES 02-27-2023 DE FS 2.0 TE R EQUIPMENT rL-AN & SCHEDULE 9,a + I F_, �' ;` ; �� .r°`',zr,�� � � i 'I _ EXCEED 1 OF 1/LEAD. I T ,� ,r' �� k _ ,I DOH SUBMITTAL 03 02 2023 DE ;' (_ /g2 v ? I 1r t', j 6 1 DOH SUBMITTAL UPDATE 03-09-2023 DE FS E OYS R BA ELECTRI PLA & SCHE - LE22 _ - 2 MEP DOCUMENTATION 03 10 2023 DE N 03-16-2023 DE CLARIFICATIONS _ M 03-27-2023 DE PU MB1 C DOH SUBMITTAL UPDATE FS 2.0 OY TER BAR UM d G PLAN SC ULE c / DOH UPDATE, PART 2 03-31-2023 DE .AI.L PLU"�'gING A t<= - ,.&WATER LINE NE D - _ P2. 1 O STER BAR FL R DRAIN/SINK PLAN BEFORE T $7ING B' 0 RING MEP UPDATE 04-05-2023 DE /, b7'�, ,>1 1- t:., ' S4. BOATHOUISE UPDATE 21 -2023 DE , '. 4 Ct I'.: ., -c.r,. t DINE UPDATE - - i { 04 e.z' _ ;: ', I o { 28 2023 DE M ' 4 `y ' 5� r• J 5s 9 BOATHOUISE UPDATE 06-09-2023 DE CLECTR C I. FS 3.0 LOBBY BAR EQUIPMENT PLAN & SCHEDULE _ INSPEG i FRAME E µ+4 a, w r' xas cr r; e , I PROJECT FS E3.0 LOBBY BAR ELECTRICAL PLAN & SCHEDULE ' _ - ' o FS P3.0 LOBBY BAR PLUMBING PLAN & SCHEDULE �� - i , .;p .Y t r- 7 1 {-' fr' I ( / /� .. %• -'2' C'?•1`\( ('i_''', 'i.!. ` I T_,. . A fin' FS P3. 1 LOBBY BAR FLOOR DRAIN/SINK PLAN '' ; k ;' '` r�3 ^ ° "°t r { .-__ / q •7 r/r , t 41J.,,,, \,�\ I f'"? ,. o�R'%���'�'G��'..' If may'-'1- dI FS M3.0 LOBBY BAR MECHANICAL PLAN i /, 9, r, :;` . ,.>' �' ' In \` y ° ,- '°` 70 i;'} "4 r 3 6 FS 4.0 BOATHOUSE EQUIPMENT PLAN 499 '' rr �' ?. �' % �, A �• r ° ° ' FS 4. 1 OATHOUSE E P NT SCHEDULE F �� FS E4. OATHOUSE ECTRI AL PLAN r t �QS�s FS E . 1 OATHOUS ELECTRI AL SC DULE ;\ti y )F FS 4.0 B ATHOU E PLUMBIN PLA I F P4. 1 B ATHO SE PLUMBIN S EDULE I �� S P4.2 B T USE FLOOR D /SINK PLAN /g� ---- 'ice .s ,Ls. � • �`'' .; _+` S SC4.0 BOA HOUSE SPECIAL CONDITIONS PLAN \ ' FS M4.0 BOATHOUSE MECHANICAL PLAN a i SCALE I y 4 AS NOTED Of FS FAB1 .0 1 . 1 CAPTIVE AIRE FABRICATION DRAWINGS '°a ''° DRAWING ��No FS FAB2.0-2.4 ATHANOR FABRICATION DRAWINGS / covE� SHE 9 Of FS FAB3.0 CANTILEVER FABRICATION DRAWING ;; a 684 KEY PLAN BOATHOUSE OYSTER BAR SCALE: 1 /32 "= 1 '-0" DRAWING NU �D�_ _ ESS10�P� 3js FS ELEV1 .0 ELEVATIONS LOCATION LOCATION k r e dxf 4 S A U G - 3 2023 r-UTLD TIN G r,F1 r. T()S' 'ti � U g. N 4 ' @ Q O_ j cD 0 U Q U O 0 o E a a r U 11 O a t N c W T .__--- --- : - o a 9 m IN t C cu 70 ,) 5 -6 5 - 6J. , 36 East 31 st Street, 6th Floor 3' 2'-10 3' New York, New York 10016 " Tel: (212)244-0008 ri Fax: I(212)244-0057 emaill: jkouveras a samtell.com O DOUBLE 1�011VERSHELVES OTLINE TUBULAR HAND SINKS & SINGLE OVERSHELF POT SHELVES RELEASE TOP TIER & DISH RACKS 8 REV. CONCEPT DESIGN 12-12-2022 DE OVERSHELVES MOP SINKS ( 9 DESIGN DEVELOPMENT 12-13-2022 DE 10 MEP SUBMISSION 12-23-2022 AO 11 MEP SUBMISSION 12-28-2022 AO 12 MEP SUBMISSION 01-03-2023 AO 13 MEP SUBMISSION 01-05-2023 AO 14 OYSTER BAR CONCEPT 01-19-2023 DE 15 OYSTER BAR REVISIONS 01-25-2023 KK 16 OYSTER BAR REVISIONS 01-31-2023 DE 17 OYSTER LOBBY BAR MEP 02-10-2023 DE 18 BACKGR'OUND UPDATE 02-24-2023 DE 19 DINETTE: MEP SCHEDULES 02-27-2023 DE DOH SUIBMITTAL 03-02-2023 DE 1 DOH SUBMITTAL UPDATE 03-09-2023 DE MEP DC)CUMENTATION 03-10-2023 DE 2 CLARIFICATIONS 03-16-2023 DE 24 DOH SUBMITTAL UPDATE 03-27-2023 DE DOH UPDATE, PART 2 03-31-2023 DE MEP UPDATE 04-05-2023 DE BOATHOUSE UPDATE 04-21-2023 DE DINETTE UPDATE 04-28-2023 DE 9 BOATHO'USE UPDATE 06-09-2023 DE PROJECT 0 0 ul �, cr cr c � cr P, 8)_ 6i I )) WPM m 7)_2)) 6 6' C� 4)_ 7" 4)_ 8)) 4)_ 8)) 3' 3' SCALE N.T.S. 4F New Y R'1 DRAWING CONDO + STANDARD INSTALLATION �� ��� 4 W' DETAILS CI PRE-RINSE 6 TYPICAL UBLE OVERSHELVES UBLE OVERSHELVES FAUCET BRACKET WATER FILTER ABLE MOUNT CEILING MOUNT 5� Qom' DRAWING NUMBER OFESS��� U N co(Y 711, y — IZ S3. (6 Q O qq U O N ••—••—••—�•�•• seaex as - ••-�••—•• —__—__—__—__—__—__—__ __—__— — _ ■asseas.�wsae■ __—__ __ I ' NO Ill�'_.. !N._....__.f1t_IV �.._.__.l_�. . . �=...- ���! �r .Sor�ls -- ! i I I Q 1 5 !----_----- 1.1 ------'- ----. _ H5.1 \4\'-9Y" - cz -------+ "I LU o 0 )T(T cc—c � I LF- 5a-s:u. >IL OPEN STORAGE c cu C77",7- A10 22 3 2'-7 o°o° AND IN ' rT i Ir1 „,5 9 I ,— 13.3 :dal W„ 6 I ' 35 I/ REF— REF —REF it __WWE 8 =- I a !j ! == 36 East 31st Street 6th Floor 13 17 34 HAND SINK -- I, , 3 AccEss \� 3' L ------------- --- -- -- ----�-- II New York, New York 10016 _.-- . ..._...--_- 221 : Tel: (212)244-0008 TYPE /��oA _ ' - 33 rl � 0057 ------ � 7 I Fax• (212)244 STORA E emai 1: jkouveras@samtell.com REVDvaeLE ENTER 13.1 - ALL-- EXTENSION --�..--- — -- 13.2 ------------- __ "= --] �� RELEASE 0 8 REV. CONCEPT DESIGN 12-12-2022 DE 9 DESIGN DEVELOPMENT 12-13-2022 DE LOBBY BAR 10 MEP SUBMISSION 12-23-2022 AO E I I SEE FS3.0 FOR EQUIPMENT ED11 MEP SUBMISSION 12-28-2022 AO 39 REF PLAN AND SCHEDULE 12 MEP SUBMISSION 01-03-2023 AO 13 MEP SUBMISSION 01-05-2023 AO 14 OYSTER BAR CONCEPT 01-19-2023 DE 15 OYSTER BAR REVISIONS 01-25-2023 KK 55 I 16 OYSTER BAR REVISIONS 01-31-2023 DE MAY- IV+f�t �� ©� --0�(.� /I�( e�r r S(�dF.... la--- F-- �5 -uc)/� s I„ I 3'-6" 17 OYSTER' LOBBY BAR MEP 02-10-2023 DE I— — - 18 BACKGFROUND UPDATE 02-24-2023 DE --J r-----� 19 DINETTE MEP SCHEDULES 02-27-2023 DE 54 ---- DOH SUBMITTAL 03-02-2 STORAGE023 DE 42 1 DOH SUBMITTAL UPDATE 03-09-2023 DE 48 i MEP DOCUMENTATION 03-10-2023 DE 3 5 43.1 47 I 38 RIIUBMITTAL UPDATE 03-27-2023 DE OPEN 03-16-2023 DE STORAGE DOH S I REF DOH UPDATE, PART 2 03-31-2023 DE rL P, r S - i MEP UPDATE 04-05-2023 DE - - - - - - - - - - - - - - - - - - - 27 - - - - - - - - - - - - - - - - - - - O i I I �I i r- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -------- BOATHOUSE UPDATE 04-21-2023 DE �t � I I DINETTE: UPDATE 04-28-2023 DE o 9 BOATHO)USE UPDATE 06-09-2023 DE -v - L hD46 44 28 (16(:26D PROJECT 45 43 23 I j ! Lu i 0 ABBREVIATIONS HW HOT WATER 140 JB JUNCTION BOX CW COLD WATER SR SINGLE RECEPTACLE DW DIRECT WASTE OR DUPLEX RECEPTACLE IW INDIRECT WASTE CP CORD AND PLUG SCALD FD FLOOR DRAIN SW SWITCH FM FUNNEL FLOOR DRAIN HP HORSE POWER FS FLOOR SINK KW KILOWATTS (22" x 3 4") 1/4" _ —0 ® (11" X 17") =1 —0" G GAS V VOLTAGE BTU BRITISH THERMAL UNIT GU GENERAL USEDRAWING4 S STEAM ; CR CONDENSATE RETURN REF RECEPTACLE LP LIQUID PROPANE AF ABOVE FINISHED FLOOR DINETTE EOF ELECTRICAL OUTLET IN FLOOR CFM CUBIC FEET PER MINUTE BTC BRANCH TO CONNECT EQUIPMENT PLAN SP STATIC PRESSURE DFA DOWN FROM ABOVE — PSI POUNDS PER SQUARE INCH OOW OUT OF WALL n� HVAC HEATING/VENTILATING CONTRACTOR ID INSIDE DIAMETER EC ELECTRICAL CONTRACTOR IPS IRON PIPE SIZE �\ C J KEC KITCHEN EQUIPMENT CONTRACTOR OD OUTSIDE DIAMETER Lj� �� 5 N GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MINUTE 11ApC PC PLUMBING CONTRACTOR FP FIRE PULL BOX DRAWING N U Ir Y Pea G NIC NOT IN CONTRACT SO SMOKE DETECTOR WC WATER COLUMN AV AUDIO VISUAL DEVICE CWS COLD WATER SUPPLY NG NATURAL GAS I CWR COLD 4ATER RETUR � ri t ON EQUIPMENT SCHEDULE U ITEM Q NO QTY EQUIPMENT CATEGORY MANUFACTURER MODEL NUMBER EQUIPMENT REMARKS _n @ 1 1 JuNDERBAR 3 COMPARTMENT SINK KROWNE KR19-53C W/ 4" HIGH BACKSPLASH =• m 1.1 3 SINK COVER DIAMOND GROUP SC-14X1O S/S MATT; FITTED INTO TRIPLE SINK (ITEM #1) 3 2 1 UNDERCOUNTER REFRIGERATION PERLICK HD24RS4 SELF-CONTAINED; W/ S/S FINISH o U 3 1 MILLWORK COUNTER & DIE WALL BY OTHERS N/A BY OTHERS; 11" OVERHANG FOR GUEST DINING 4 1 MILLWORK STORAGE BY OTHERS N/A BY OTHERS a E r Y o U 5 1 UNDERBAR ICE CHEST KROWNE KR19-18 W/ 4" HIGH BACKSPLASH 5.1 1 UNDERBAR SPEED RAIL KROWNE RS-18 - o 6 1 UNDERCOUNTER REFRIGERATION, ADA PERLICK HB24WS4 SELF-CONTAINED; W/ GLASS DOOR HINGED ON RIGHT; TEMPERATURE RANGE = 40 - 68 DEGREES 3 ' o 7 1 IMILLWORK REMOVABLE ADA COUNTER BY OTHERS N/A BY OTHERS 8 1 IMILLWORK COUNTER & DIE WALL BY OTHERS N/A BY OTHERS; 104" L. X 24" W X 36" H - - o E 9 1 1'0S STATION W/ PRIVER BY OWNER N/A - 10 1 DRINK RAIL BY OTHERS DR-5X122 BY OTHERS co 11 1 OPEN NUMBER 12 1 �NDERCOUNTER REFRIGERATION, ADA PERLICK HB24WS4 SELF-CONTAINED; W/ GLASS DOOR HINGED ON LEFT; TEMPERATURE RANGE = 40 - 68 DEGREES ' `o 13 1 EXHAUST HOOD ASSEMBLY CAPTIVE AIRE EXHAUST HOOD - _U 13.1 1 FIRE SUPPRESSION SYSTEM INTERSTATE FIRE & SAFETY ANSUL WALL MOUNTED17 U 13.2 1 HOOD CONTROL PANEL CAPTIVE-AIRE CONTROL PANEL REFER TO FAB. DWGS. 13.3 1 ANSUL PULL STATION INTERSTATE FIRE & SAFETY ANSUL WALL MOUNTED 13.4 1 THERMISTOR, 1.8K SENSOR OUTPUT, LCD DISPLAY AUTOMATION COMPONENTS, INC. A/1.8K-R-LCD-F (124245) W/MOUNTING PLATE #106821 { 14 1 OVEN, FINISHING EQUIPEX SEM-60VC SITS ON TUBULAR SHELF o 15 1 ELECTRIC COOKING SUITE ATHANOR E-SUITE W/ MULTI COOKER, TWO ZONE PLAQUE, (2) TWIN RADIANT HOBS UNDER VITRO, TWIN FRYER, & ELECTRIC OVEN IN BASE; W/ BACK/SIDES SPLASHES (ON 3 SIDES) s ...DT21-8 -- 16 1 TUBULAR OVERSHELF ADVANCE TABCO - -^--- �-* * 0 17 1 REFRIGERATOR, UNDERCOUNTER BEVERAGE-AIR UCRD72AHC-6 SELF-CONTAINED; W/ 3" CASTERS; REMOVE RUBBER STOPS IN BACK FOR FIT UP a 18 1 UNDERBAR FILLERS & DRAINBOARDS GLASTENDER DBCA-18-LD - T LU 19 1 OPEN NUMBER 20 1 OPEN NUMBER - - - 0 21 1 OPEN NUMBER - - - n n 22 2 HEAT LAMP, DECORATIVE HATCO DLH-725-ASR (2) 375 WATT LAMPS; HEIGHT FROM 42" TO 72"; RIGHT NICKEL FINISH; INTERCONNECTED TO REMOTE SWITCH ON WALL `0 22.1 1 REMOTE SWITCH FOR HEAT LAMP HATCO DL-SWITCH-16AMP CONNECTED TO O 2 HEAT LAMPS a 23 1 ESPRESSO MACHINES, AUTOMATIC - GROUP 1 LA MARZOCCO LINEA CLASSIC S 1 AV BY OWNER rN� °7 24 1 OPEN NUMBER 25 1 REFRIGERATOR, REACH-IN CONTINENTAL REFRIGERATOR 1 RN SELF-CONTAINED; DOOR HINGE ON LEFT 26 1 WATER FILTER EVERPURE EV433991 BY OWNER; MOUNTED UNDERCOUNTER 26.1 1 ATER FILTER EVERPURE EV9293-01 BY OWNER; MOUNTED UNDERCOUNTER -,X VJ 27 1 WAREWASHER, UNDERCOUNTER, HIGH TEMP ECOLAB E-UHT LEASED BY OWNER; W/DRAIN WATER TEMPERING KIT INSTALLED BY E.C. & P.C. 28 1 COFFEE GRINDER LA MARZOCCO USA MAZZER ROBUR E GRINDER BY OWNER 36 East 31st Street, 6th Floor New York New York 10016 29 1 OPEN NUMBER - - - 30 1 OPEN NUMBER - - - Tel: (212)244-0008 31 1 OPEN NUMBER - - - ax: 212)244-0057 32 1 OPEN NUMBER - - - email: jkouveras@samtell.com 33 4 SHELVING, WIRE METRO MQ2436G W/ (4) STATIONARY POSTS (74PS); 34 1 TRASH RECEPTACLE, "SLIM JIM" CARLISLE 342023-03 - 35 1 CHEF'S PASS TABLE DIAMOND GROUP CHPT-30X111 W/ 18X12X12 SINK & T&S FAUCET (B-0221-CC); TRASH CHUTE; SIDE PANELS FOR TRASH ACCESS & SINK ACCESS; TO ACCOM. U/C REF & TRASH BIN; COUNTERTOP BY OTHERS; KICK PLATES; (2) DOGHOUSES RELEASE 35.1 1 IHAND SINK SIDE SPLASH DIAMOND GROUP HS-SS - 8 REV. CONCEPT DESIGN 12-12-2022 DE 36 1 OPEN NUMBER - - - 9 DESIGN DEVELOPMENT 12-13-2022 DE 37 1 MOP SINK CABINET REGENCY 60OSMC25SD BY OWNER 10 MEP SUBMISSION 12-23-2022 AO 38 1 MILLWORK COUNTER BY OTHERS N/A BY OTHERS; HEIGHT TO BE 36" 11 MEP SUBMISSION 12-28-2022 AO 39 1 MOP BUCKET BY OTHERS N/A - 12 MEP SUBMISSION 01-03-2023 AO 40 1 OPEN NUMBER - - - 13 MEP SUBMISSION 01-05-2023 AO 41 1 OPEN NUMBER - - - 14 OYSTER BAR CONCEPT 01-19-2023 DE . 42 1 POS STATION W/ PRINTER BY OWNER N/A - 15 0YSTEIR BAR REVISIONS 01—25-2023 KK 43 1 SINK, DROP—IN EAGLE GROUP/METAL MASTERS SR10-14-5-1 MOUNTED UNDER COUNTER; W/ BOTTOM—MOUNT KIT (362188) 1 6 0YSTEIR BAR REVISIONS 01-31-2023 DE 43.1 2 HAND SINK SIDE SPLASH DIAMOND GROUP HS—SS (19X6) — 170YSTER LOBBY BAR MEP 02-10-2023 DE 44 1 PITCHER RINSER RHINO RHPR300 DROPPED INTO MILLWORK COUNTER 18BACKGR0UND UPDATE 02-24-2023 DE 45 1 COFFEE MAKER, INSULATED SERVER, AUTOMATIC FETCO CBS-1131V+ BY VENDOR; E113151 ELEC. CODE; W/ THERMAL DISPENSER #451 19 DINETTE MEP SCHEDULES 02-27-2023 DE 46 1 SINK, DROP—IN EAGLE GROUP/METAL MASTERS SR14-16-9.5-1 MOUNTED UNDER COUNTER; W/ BOTTOM—MOUNT KIT (362188) DOH SUBMITTAL 03-02-2023 DE 47 1 KNOCKBOX VOLLRATH E06064—KB BY OWNER; DROPPED INTO MILLWORK COUNTER 1 DOH SUBMITTAL UPDATE 03-09-2023 DE 48 1 TRASH RECEPTACLE, "SLIM JIM" CARLISLE 342023-03 — 22 MEP DIOCUMENTATION 03-10-2023 DE 2 CLARIFICATIONS 03-16-2023 DE 49 1 OPEN NUMBER — — — DOH SUBMITTAL UPDATE 03-27-2023 DE 50 1 OPEN NUMBER — — — 25IDOH UPDATE, PART 2 03-31—2023 DE 51 1 OPEN NUMBER — — — 26MEP UPDATE 04-05-2023 DE 52 1 OPEN NUMBER - - - 27 BOATHpUSE UPDATE 04-21-2023 DE 53 1 UNDERCOUNTER REFRIGERATION, ADA PERLICK HB24RS4 SELF—CONTAINED 28DINETTE UPDATE 04-28-2023 DE 54 1 MILLWORK COUNTER BY OTHERS N/A BY OTHERS; W/ OPEN STORAGE; HEIGHT TO BE 36" 29 BOATHOUSE UPDATE 06-09-2023 DE 55 1 FREEZER, UNDERCOUNTER HOSHIZAKI AMERICA JEUF27A SELF-CONTAINED T � - - /I/C 0,5 7-0 r PROJECT m 1V0 --- _13_LL -IS('! CFS� l'r. _�._1� .i/ l�` DLMF' [S IUnjS_. '}NJ oCN '(`u(Ql Ol�l (b C2c iV�U:�(`�l lCc- Z00 !t E"^� ^ oos 0 W. ABBREVIATIONS ' HW HOT WATER 140 JB JUNCTION BOX CW COLD WATER SR SINGLE RECEPTACLE DW DIRECT WASTE DR DUPLEX RECEPTACLE IW INDIRECT WASTE CP CORD AND PLUG SCALE FD FLOOR DRAIN SW SWITCH FM FUNNEL FLOOR DRAIN HP HORSE POWER N,T.S. GFLOOR SINK KW KILOWATTS BTU GAS THERMAL UNIT V VOLTAGE GU GENERAL USE S STEAM RECEP, RECEPTACLE DRAINING CR CONDENSATE RETURN AFF ABOVE FINISHED FLOOR DINETTE LP LIQUID PROPANE EOF ELECTRICAL OUTLET IN FLOOR SI D CUBIC FEET PER MINUTE BTG BRANCH TO CONNECT EQUIPMENT SCHEDULE SP STATIC PRESSURE DFA DOWN FROM ABOVE PSI POUNDS PER SQUARE INCH COW OUT OF WALL HVAC HEATING/VENTILAnNG CONTRACTOR ID INSIDE DIAMETER EC ELECTRICAL CONTRACTOR IPS IRON PIPE SIZE KEC KITCHEN EQUIPMENT CONTRACTOR OD OUTSIDE DIAMETER GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MINUTE PC PLUMBING CONTRACTOR FP FIRE PULL BOX DRAWING N U M F3 E R F NIC NOT IN CONTRACT SD SMOKE DETECTOR WC WATER COLUMN AV AUDIO VISUAL DEVICE S I CWS COLD WATER SU PPLY NG NATURAL GAS _AR COLD ATER RETUR 4 N N .O O U N U Q f6 U CL C OU O y O d � N N (O I ji . II j 1 � III b I 111 I o 39'AFF G.U. 1 II 15'-7" I I I o 5'-8" 2' i -------------- ---- ----- — ----- LU _ _ � I ! I ' I I CL DFA == 22 17 it I --� I ; I --- I I I I I I 3 III r-113/4" I 1 J : J \\ 13.4 s P I -___T 1 , I 4" - ------ _ I i 1 6 REFER TO CAPTIVE AIRE FAB_ /, DWGS FOR POI T TO POINT c.u. j jl j L__ ; 36 East 31st Street 6th Floor ' ----- 12 J9 �— ----------------- -- -------•—� I New York New York 10016 DIAGRA S G.U. 15 siu�cr G.U. 14 ;12 erc 24'AFF 24'AM I �_ vi855 =°---__ 1 II 7" 4'-10" 4'-11" 3'-3" I �s�11 ----- �- 22.t ----------- -- ----- ----- -- Tel: -(212)244 0008 PENDING ATHANOR FAB. - DWGS FOR POINT TO POINT j I r'"� — _ 1 I I i it DIAGRA S J `,i I - ax:; 2 2 4-0057 em aail: jkouveras samtell.com �. ..— yy RELEASE 25 ; 8 1 REV. CONCEPT DESIGN 12-12-2022 DE 6" _J° 9 DESIGN DEVELOPMENT 12-13-2022 DE 10 MEP SUBMISSION 12-23-2022 AO Li I 11 MEP SUBMISSION 12-28-2022 AO 12 MEP SUBMISSION 01-03-2023 AO 13 MEP SUBMISSION 01-05-2023 AO 0 14 OYSTER BAR CONCEPT 01-19-2023 DE 15 OYSTER BAR REVISIONS 01-25-2023 KK V-4" 16 OYSTER BAR REVISIONS 01-31-2023 DE 55 17OYSTEIR LOBBY BAR MEP 02-10-2023 DE .I 18 BACKGROUND UPDATE 02-24-2023 DE r-----7 19 DINETTE MEP SCHEDULES 02-27-2023 DE DOH SUBMITTAL 03-02-2023 DE I I ----� 1 DOH SUBMITTAL UPDATE 03-09-2023 DE I I 1 i 4" 42 MEP DOCUMENTATION 03-10-2023 DE I 2 CLARIFICATIONS 03-16-2023 DE DOH SUBMITTAL UPDATE 03-27-2023 DE I 4'-6" DOH UPDATE, PART 2 03-31-2023 DE MEP UPDATE 04-05-2023 DE 1 �------------------------------------------------------------------------------------------------------------------------- ATHOUSE UPDATE 04-21-2023 DE I " `` DINETTE UPDATE 04-28-2023 DE J DE 9 BOATHOUSE UPDATE 06-09-2023 I 8"L 27 53 45;— 11 M-C( - 28 23 PROJECT ilk po 1 I j ®lc , E_s !©_/-f'�5 Q .Y C f.�Ft'� CAL L !{5 ---`3-J�-,. U'� C' 7)( �- 1r2 —^lCfU151 - -— - — GENERAL ELECTRICAL NOTES C'-' �, ELECTRICAL SYMBOLS LEGEND 1. ALL WORK DONE IN ACCORDANCE WITH ALL LOCAL CODES. /�E DUPLEX RECEPTACLE, HORIZONTAL MOUNT ' `rr+F CONVENIENCE OUTLET 120V/IPH/20AMP 2. SEE ELECTRICAL ENGINEERING PLANS BY OTHERS FOR COMPLETE w UNLESS OTHERWISE INDICATED SCOPE OF WORK AND ELECTRICAL SPECIFICATIONS. ABBREVIATIONS 1 SINGLE RECEPTACLE, HORIZONTAL MOUNT 3, ELECTRICIAN TO SUPPLY AND INSTALL ALL DUPLEX RECEPTACLES (� REQUIREMENTS AS INDICATED AND SWITCHES WITH STAINLESS STEEL FACE PLATES. HVI HOT WATER 140 JB JUNCTION BOX 4. ELECTRICIAN TO SUPPLY ALL NECESSARY CONTRACTORS, STARTERS GW COLD WATER m JUNCTION Box AND DISCONNECTS. DW DIRECT WASTE SR SINGLE RECEPTACLE DR DUPLEX RECEPTACLE 5. ELECTRICIAN TO SUPPLY CONTRACTORS AND/OR SHUNT TRIP BREAKERS IW INDIRECT WASTE CP CORD AND PLUG ❑ ELECTRICAL CONNECTION TO PROVIDE FOR TOTAL FUEL SHUT—OFF TO COOKING BATTERY. SCALE FD FLOOR DRAIN SW SWITCH FFD FUNNEL FLOOR DRAIN DROP CORD FROM ABOVE 6. ELECTRICIAN TO INTERWIRE CONDENSING UNIT WITH EVAPORATOR COILS (22" x 34") 1/4" = V-0" ® (11" x 17") "=1'—O" FS FLOOR SINK HP HORSE POWER HEIGHT AS INDICATED IN WALK—IN COOLERS/FREEZERS UNITS. G GAS KW KILOWATTS ( ) V VOLTAGE 7, ELECTRICIAN TO PROVIDE AND INSTALL HEAT TAPE AROUND CONDENSATE D RAIi l G BTU BRITTSH THERMAL UNIT GU GENERAL USE • STUB UP CONDUIT DRAIN LINES IN WALK—IN FREEZERS. S STEAM RECEP. RECEPTACLE CR CONDENSATE RETURN AFF ABOVE FINISHED FLOOR 8. ELECTRICIAN TO INTERWIRE FIRE EXTINGUISHING SYSTEM WITH EXHAUST DINETTE LP LIQUID PROPANE EOF ELECTRICAL OUTLET IN FLOOR IO SAFETY DISCONNECT SWITCH (SDS) FAN AND COOKING BATTERY TO CAUSE FAN TO TURN ON AND COOKING BATTERY TO TURN OFF WHEN FIRE SYSTEM IS ACTIVATED. CFM CUBIC FEET PER MINUTE BTC BRANCH TO CONNECT ELECTRICAL PLAN SP STATIC PRESSURE DFA DOWN FROM ABOVE SWITCH 9. SEE FOOD SERVICE SPECIAL CONDITION PLAN FOR CONDUIT REQUIREMENTS PSI POUNDS PER SQUARE INCH COW OUT OF WALL FOR BEER AND SODA LINES. HVAC HEATING/VENTILATING CONTRACTOR ID INSIDE DIAMETER (]� EC ELECTRICAL CONTRACTOR IPS IRON PIPE SIZE MANUAL PULL STATION (FIRE SUPPRESSION SYSTEM) 10. ELECTRICAL TO FLUSH MOUNT ALL ROUGH—IN'S IN BAR DIE WALL AND AT KEC KITCHEN EQUIPMENT CONTRACTOR I BAR AREA, OD OUTSIDE DIAMETER R� GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MINUTE P.O.S. CONNECTION (CAT 5) 11. VERIFY ALL P.O.S. LOCATIONS AND REQUIREMENTS WITH P.O.S. DRAWING N U IYI O E R PC PLUMBING CONTRACTOR FP FIRE PULL BOX CONTRACTOR. NIC NOT IN CONTRACT SD SMOKE DETECTOR WC WATER COLUMN Ay AUDIO yISUAL DEVICE TELEPHONE JACK 12. ELECTRICAL CONNECTION (WIRING) FROM �APORATOR COIL TO LIGHTS, r e CWS COLD WATER SUPPLY NG NATURAL GAS DOOR HEATER, DOOR LIGHT, DIGITAL ALARM AND RHODES SWITCH BY r Qp� SIC 1j,� CWR COLD ATER RETURN OTHERS. r i t ELECTRICAL SCHEDULE cu U i N 9 a Z f6 UCDZ i J Q CJ W D ITEM -3:: a- O = >- -i w OLD ' NO QTY EQUIPMENT CATEGORY MANUFACTURER MODEL NUMBER a Y = > IZQ ELECTRICAL REMARKS 1 a 1 UNDERBAR 3 COMPARTMENT SINK KROWNE KR19-53C - - - - - - - - - - - E 1.1 3 SINK COVER DIAMOND GROUP SC-1010 i . d O 2 1 UNDERCOUNTER REFRIGERATION PERLICK HD24RS4 1.6 - 0.2 120 1 60 - X 5-15P 12 DUPLEX RECEPTACLE a� 3 1 MILLWORK COUNTER & DIE WALL BY OTHERS N/A 4 1 MILLWORK STORAGE BY OTHERS N/A 5 1 UNDERBAR ICE CHEST KROWNE KR19-18 - - - - - - - - - - - ., a� 5.1 1 UNDERBAR SPEED RAIL KROWNE RS-18 - - - - - - - - - - - E 6 1 UNDERCOUNTER REFRIGERATION, ADA PERLICK HB24WS4 1.6 - 0.2 115 1 60 - X 5-15P 12 DUPLEX RECEPTACLE R 7 1 MILLWORK REMOVABLE ADA COUNTER BY OTHERS N/A 8 1 MILLWORK COUNTER & DIE WALL BY OTHERS N/A - - - - - - - - - - - 9 1 POS STATION W/ PRINTER BY OWNER N/A 3.0 - - 120 1 60 - X 5-15P 30 DUPLEX RECEPTACLE; DEDICATED CIRCUIT W/ ISOLATED GROUND; POS DATA LINE (CAT 5); VERIFY EXACT UTILITIES W/ OWNER c 10 1 DRINK RAIL BY OTHERS DR-5X122 - - - - - - 11 1 OPEN NUMBER 12 1 UNDERCOUNTER REFRIGERATION, ADA PERLICK HB24WS4 1.6 - 0.2 115 1 60 - X 5-15P 12 DUPLEX RECEPTACLE " """"""" ^'"""' 2 13 1 EXHAUST HOOD ASSEMBLY CAPTIVE AIRE EXHAUST HOOD - - - - - - - - - - REFER TO CAPTIVE AIRE FAB. DWGS FOR POINT TO POINT DIAGRAMS 13.1 1 FIRE SUPPRESSION SYSTEM INTERSTATE FIRE & SAFETY ANSUL - - - - - - - - - - REFER TO CAPTIVE AIRE FAB. DWGS FOR POINT TO POINT DIAGRAMS 7 13.2 1 HOOD CONTROL PANEL CAPTIVE-AIRE CONTROL PANEL - - - - - - - - - - INTERCONNECTED TO EXHAUST HOOD (ITEM #13) & FIRE SUPPRESSION SYSTEM (ITEM #13.1);REFER TO CAPTIVE AIRE FAB. DWGS FOR POINT TO POINT DIAGRAMS „_•,y,__, 13.3 1 ANSUL PULL STATION INTERSTATE FIRE & SAFETY ANSUL - - - - - - - - - - - 0 13.4 1 THERMISTOR, 1.8K SENSOR OUTPUT, LCD DISPLAY AUTOMATION COMPONENTS, INC. A/1.8K-R-LCD-F (124245) 1.0 - - 24 1 60 X - - 48 JB BTC 14 1 OVEN, FINISHING EQUIPEX SEM-60VC 13.0 1 3.0 - 208-240 1 1 60 - X 6-20PI 65 SINGLE RECEPTACLE _A m 15 1 ELECTRIC COOKING SUITE ATHANOR E-SUITE 14.5 3.0 - 208 1 60 X - - 4 (12) JBS STUB-UP; (2) ® 14.5A 208V/1 PH; (6) @ 17A 208V/1 PH; (2) ® 25A 208V/3PH; (2) ® 8.5A 208V/3PH; PENDING ATHANOR SHOP DRAWINGS; LEAVE 120" TAILS AT POINTS SHOWN ON DRAWING W _ _ _ - 17.0 3.5 - 208 1 60 X - - 4 - _ 7m 25.0 9.0 - 208 3 60 X - - 4 - o n - 8.5 3.0 - 208 3 60 X - - 4 - a o 16 1 TUBULAR OVERSHELF ADVANCE TABCO DT21-8 - - - - - - - - - - - m �.► 17 1 REFRIGERATOR, UNDERCOUNTER BEVERAGE-AIR UCRD72AHC-6 3.0 - 0.2 115 1 60 - X 5-15P * DUPLEX RECEPTACLE BTC FROM BAR 18 1 UNDERBAR FILLERS & DRAINBOARDS GLASTENDER DBCA-18-LED - - - - - - - - - - - ,/ , B 19 1 OPEN NUMBER 20 1 OPEN NUMBER a 21 1 OPEN NUMBER - - - - - - - - - - - - - sa,, x.w' i . , U) 22 2 HEAT LAMP, DECORATIVE HATCO DLH-725-ASR 6.2 0.8 - 120 1 60 IX - - * JB DFA BTC 22.1 1 REMOTE SWITCH FOR HEAT LAMP HATCO DL-SWITCH-1 6AMP - - - - - - - - - - CONNECTED TO (2) HEAT LAMPS (ITEM #22) 3 6 East 31 st Street, 6th Floor 23 1 ESPRESSO MACHINES, AUTOMATIC - GROUP 1 LA MARZOCCO LINEA CLASSIC S 1 AV 12.0 2.5 - 208-240 1 60 - X 6-20P 50 SINGLE RECEPTACLE New York, New York 10016 24 1 OPEN NUMBER - - - - - - - - - - - - - Te : (212)244-0008 25 1 REFRIGERATOR, REACH-IN CONTINENTAL REFRIGERATOR iRN 5.2 - 0.2 120 1 60 - X 5-15P 86 DUPLEX RECEPTACLE Fax: (212)244-0057 26 1 WATER FILTER EVERPURE EV433991 - - - - - - - - - - - ennall: jkouveraS @ samtell.Con1 26.1 1 WATER FILTER EVERPURE EV9293-01 - - - - - - - 27 1 WAREWASHER, UNDERCOUNTER, HIGH TEMP ECOLAB E-UHT 33.0 - 1.0 1 208 1 60 X - - 12 JB BTC; E.C. TO SUPPLY & INSTALL CUT-OFF SWITCH; DRAIN WATER TEMPERING KIT TO BE INSTALLED BY E.C. 28 1 COFFEE GRINDER LA MARZOCCO USA MAZZER ROBUR E GRINDER 8.1 0.9 - 110 1 60 - X 5-15P 50 DUPLEX RECEPTACLE RELEASE 29 1 OPEN NUMBER - - - - - - - - - - - - - 8 REV. CONCEPT DESIGN 12-12-2022 DE 30 1 OPEN NUMBER - - - - - - - - - - - - 9 DESIGN DEVELOPMENT 12-13-2022 DE 31 1 OPEN NUMBER - - - - - - - - - - - - - 10MEP SUBMISSION 12-23-2022 AO 32 1 OPEN NUMBER - - - - - - - - - - - - - 11MEP SUBMISSION 12-28-2022 AO 33 4 SHELVING, WIRE METRO MQ2436G - - - - - - - - - - - 12 MEP SUBMISSION 01-03-2023 AO 34 1 TRASH RECEPTACLE, "SLIM JIM" CARLISLE 342023-03 - - - - - - - - - - - 1 3 MEP SUBMISSION 01-05-2023 AO 35 1 CHEF'S PASS TABLE DIAMOND GROUP CHPT-30X111 - - - - - - - - - - - 14 OYSTER BAR CONCEPT 01-19-2023 DE 35.1 1 HAND SINK SIDE SPLASH DIAMOND GROUP HS-SS - - - - - - - - - - - 15 OYSTER BAR REVISIONS 01-25-2023 KK 36 1 OPEN NUMBER - - - - - - - - - - - - - 1 6 OYSTER BAR REVISIONS 01-31-2023 DE 37 1 MOP SINK CABINET REGENCY 600SMC25SD - - - - - - - - - - - 1 7 OYSTER LOBBY BAR MEP 02-1 0-2023 DE 38 1 MILLWORK COUNTER BY OTHERS N/A - - - - - - - - - - - 1 8 BACKGROUND UPDATE 02-24-2023 DE 39 1 MOP BUCKET BY OTHERS N/A - - - - - - - - - - - 19 DIINETTE MEP SCHEDULES 02-27-2023 DE 40 1 OPEN NUMBER - - - - - - - - - - - - DOH SUBMITTAL 03-02-2023 DE 41 1 OPEN NUMBER - - - - - - - - - - - - - 1 DOH SUBMITTAL UPDATE 03-09-2023 DE 42 1 POS STATION W/ FRINTER BY OWNER N/A 3.0 - - 120 1 60 - X 5-15P 30 DUPLEX RECEPTACLE; DEDICATED CIRCUIT W/ ISOLATED GROUND; POS DATA LINE (CAT 5); VERIFY EXACT UTILITIES W/ OWNER 2 MEP DOCUMENTATION 03-10-2023 DE 43 1 SINK, DROP-IN EAGLE GROUP/METAL MASTERS SR10-14-5-1 - - - - - - - - - - - 2 CLARIFICATIONS 03-16-2023 DE 43.1 2 HAND SINK SIDE SPLASH DIAMOND GROUP HS-SS (19X6) - - - - - - - - - - - 24IDOH SUBMITTAL UPDATE 03-27-2023 DE 44 1 PITCHER RINSER RHINO RHPR300 DOH UPDATE, PART 2 03-31-2023 DE • - - - - - - - - - - - MEP UPDATE 04-05-2023 DE 45 1 COFFEE MAKER, INSULATED SERVER, AUTOMATIC FETCO CBS-1131V+ 19.7 2.4 - 100-120 1 60 - X 5-20P 50 SINGLE RECEPTACLE 27 BOATHOUSE UPDATE 04-21 -2023 DE 46 1 SINK, DROP-IN EAGLE GROUP/METAL MASTERS SR14-16-9.5-1 - - - - - - - - - - - DINETTE UPDATE 04-28-2023 DE 47 1 KNOCKBOX VOLLRATH E06064-KB - - - - - - - - - - - 9 BOATHOUSE UPDATE 06-09-2023 DE 48 1 TRASH RECEPTACLE, "SLIM JIM" CARLISLE 342023-03 - - - - - - - - - - - 49 1 OPEN NUMBER - - - - - - - - - - - - - PROJECT 50 1 OPEN NUMBER - - - - - - - - - - - - - 51 1 OPEN NUMBER - - - - - - - - - - - - - • 52 1 OPEN NUMBER - - - - - - - - - - - - - 53 1 UNDERCOUNTER REFRIGERATION, ADA PERLICK HB24RS4 1.6 - 0.2 115 11 60 - X 5-15P 12 DUPLEX RECEPTACLE 54 1 MILLWORK COUNTER BY OTHERS N/A - - - - - - - - - - - 55 1 FREEZER, UNDERCOUNTER HOSHIZAKI AMERICA EUF27A 1.2 - 0.2 115 1 60 - X 5-15P 12 DUPLEX RECEPTACLEtu r Ora ELECTRICAL SYMBOLS LEGEND GENERAL ELECTRICAL NOTES x em 1. ALL WORK DONE IN ACCORDANCE WITH ALL LOCAL CODES. W DUPLEX RECEPTACLE, HORIZONTAL MOUNT ; CONVENIENCE OUTLET 120V/1PH/2OAMP 2. SEE ELECTRICAL ENGINEERING PLANS BY OTHERS FOR COMPLETE UNLESS OTHERWISE INDICATED SCOPE OF WORK AND ELECTRICAL SPECIFICATIONS. ABBREVIATIONS SINGLE RECEPTACLE, HORIZONTAL MOUNT 3. ELECTRICIAN TO SUPPLY AND INSTALL ALL DUPLEX RECEPTACLES REQUIREMENTS AS INDICATED AND SWITCHES WITH STAINLESS STEEL FACE PLATES. 4. ELECTRICIAN TO SUPPLY ALL NECESSARY CONTRACTORS, STARTERS HW HOT WATER 140 JB JUNCTION BOX JUNCTION BOX AND DISCONNECTS. CW COLD WATER DW DIRECT WASTE SR SINGLE RECEPTACLE DR DUPLEX RECEPTACLE 1 5. ELECTRICIAN TO SUPPLY CONTRACTORS AND/OR SHUNT TRIP BREAKERS IW INDIRECT WASTE Ej ELECTRICAL CONNECTION TO PROVIDE FOR TOTAL FUEL SHUT-OFF TO COOKING BATTERY. SCALE FD FLOOR DRAIN CP CORD AND PLUG SW SWITCH FFD FUNNEL FLOOR DRAIN 6. ELECTRICIAN TO INTERWIRE CONDENSING UNIT WITH EVAPORATOR COILS N.T.S. FS FLOOR SINK HP HORSE POWER ( AROP CORDFROM S IN WALK-IN COOLERS/FREEZERS UNITS. G GAS KW KILOWATTS (HEIGHT S INDICATED) V VOLTAGE 7. ELECTRICIAN TO PROVIDE AND INSTALL HEAT TAPE AROUND CONDENSATE DRAPING BTU BRMSH THERMAL UNIT GU GENERAL USE • STUB UP CONDUIT DRAIN LINES IN WALK-IN FREEZERS. S STEAM RECEP. RECEPTACLE I DINETTE CR CONDENSATE RETURN 8. ELECTRICIAN TO INTERWIRE FIRE EXTINGUISHING SYSTEM WITH EXHAUST AFF ABOVE FINISHED FLOOR i FAN AND COOKING BATTERY TO CAUSE FAN TO TURN ON AND COOKING LP LIQUID PROPANE EOF ELECTRICAL OUTLET IN FLOOR IO SAFETY DISCONNECT SWITCH (BEDS) BATTERY TO TURN OFF WHEN FIRE SYSTEM IS ACTIVATED. ELECTRICAL SCHEDULE CFM CUBIC FEET PER MINUTE BTC BRANCH TO CONNECT SP STATIC PRESSURE DFA DOWN FROM ABOVE SWITCH 9. SEE FOOD SERVICE SPECIAL CONDITION PLAN FOR CONDUIT REQUIREMENTS PSI POUNDS PER SQUARE INCH DOW OUT OF WALL FOR BEER AND SODA LINES. HVAC HEATING/VENTILATING CONTRACTOR ID INSIDE DIAMETER EC ELECTRICAL CONTRACTOR IPS IRON PIPE SIZE MANUAL PULL STATION (FIRE SUPPRESSION SYSTEM) 10. ELECTRICAL TO FLUSH MOUNT ALL ROUGH-IN'S IN BAR DIE WALL AND AT KEC KITCHEN EQUIPMENT CONTRACTOR OD OUTSIDE DIAMETER BAR AREA. 1�� nAI� p GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MINUTE P.O.S. CONNECTION (CAT 5) 11. VERIFY ALL P.O.S. LOCATIONS AND REQUIREMENTS WITH P.O.S. DRAWING N U M r E R PC PLUMBING CONTRACTOR FP FIRE PULL BOX CONTRACTOR. NIC NOT IN CONTRACT SD SMOKE DETECTOR WC WATER COLUMN AV AUDIO VISUAL DEVICE Q TELEPHONE JACK 12. ELECTRICAL CONNECTION (WIRING) FROM EVAPORATOR COIL TO LIGHTS, Ui CWS COLD WATER SUPPLY NG NATURAL GAS DOOR HEATER, DOOR LIGHT, DIGITAL ALARM AND RHODES SWITCH BY CWR COLD aTER RETUR OTHERS. l Lj �C ,• A/�\' ck- OA -0 4 `� N N 0 O U O .Q U IF IZ C cu CL U O 30 Q6s�'t T ' l II - , ; 0 j i ;II pj t ! I I • I Q L o _..-._ — �o 0000000 0 0 0o•ooe.:o 000 0 0 0 0 I I > o•o ,�a Rj o. :> sit oo-0000e�ao,o000000 I a _ c IW 1 ® 10 10 III II I I I ' -v > -- - - - < - , Jj__ -- I , (z __.l i �__ 36 East 31st Street, 6th Floor PENDWGS FOR POIAT TO POINT sru15 I� DIAGRAMS ® Iw 15 Gw 15 New York, New York 10016 ry -� Tel: (212)244-0008 -- -- Fax: 212)244 0057 email: jkouveras@samtell.com , ------------- ..--— _ ---_ �_-- - _= __- --- RELEASE STUB-UP U 8 REV. CONCEPT DESIGN 12-12-2022 DE 1 37 9 DESIGN DEVELOPMENT 12-13-2022 DE 10 MEP SUBMISSION 12-23-2022 AO 11 MEP SUBMISSION 12-28-2022 AO e"' 12 MEP SUBMISSION 01-03-2023 AO cW 13 MEP SUBMISSION 01-05-2023 AO HW 37 O 14 OYSTER BAR CONCEPT 01—19-2023 DE 15 OYSTER BAR REVISIONS 01—25-2023 KK i 16 OYSTER BAR REVISIONS 01-31-2023 DE 17OYSTER/LOBBY BAR MEP 02-10-2023 DE 18 BACKGROUND UPDATE 02-24-2023 DE -----J 19 DINETTE MEP SCHEDULES 02-27-2023 DE 20 DOH SUBMITTAL 03-02-2023 DE I ;�1 1 € DOH SUBMITTAL UPDATE 03-09-2023 DE : I IW IW � MEP DOCUMENTATION 03-10-2023 DE 27 23 i 2 CLARIFICATIONS 03-1 6-2023 DE 46 4424 DOH SUBMITTAL UPDATE 03-27-2023 DE DOH UPDATE, PART 2 03-31—2023 DE I — r MEP UPDATE 04-05-2023 DE ": j,i —21-2023 DE I° cc), I— BOATHOIUSE UPDATE 04 r------------------------------------------------------------------------------- ------------- --------------------------- 4; li 'I h' I i DINETTE UPDATE 04-28-2023 DE : -.-'; o 9BOATHOIUSE UPDATE 06-09-2023 DE , , 4" 4" 4" 4" 1' V-6" 2'-4" 1' 1' 2'-6" V-4"10" i PROJECT am CW 27 46 44 43 23 26 CW HW cW CW CW CW B�-! HW HWW CONN•Pr 26.1 CW CW 13TC 45 ! FJ CONN.PT DW In r_.. V�if VIM PLUMBING SYMBOLS LEGEND GENERAL PLUMBING NOTES 1. ALL WORK DONE IN ACCORDANCE WITH ALL LOCAL CODES. • HW, CW, DIRECT DRAIN STUB UP v"m 2. ALL WATER LINES TO HAVE SHUT-OFF VALVE. E■■'�,'`*a� .""=.4 •.® 9 GAS CONNECTION STUB UP 3. PLUMBER TO PROVIDE DISHWASHER HOT WATER AT 140-F MINIMUM CONSTANT SUPPLY. '• f� 4 DIRECT STEAM CONNECTION 4. ALL INTERCONNECTING AND FINAL CONNECTIONS BY PLUMBER. O CONNECTION 5. SEE PLUMBING ENGINEERING PLANS BY OTHERS FOR COMPLETE SCOPE OF WORK AND PLUMBING SPECIFICATIONS. ABBREVIATIONS El FLOOR SINK WITH HALF GRATE 6. THE HOT WATER HEATER TO BE SIZED TO MAXIMUM USE DEMANDS OF ALL PLUMBING FIXTURES. HW HOT WATER 140 JB JUNCTION BOX ® FLOOR DRAIN 7. PLUMBER TO PIPE DRAINS FROM WALK-IN COOLFR/FREEZER CW COLD WATER SR SINGLE RECEPTACLE EVAPORATOR UNITS TO OPEN SITE DRAIN. USE COPPER PIPE ONLY. DW DIRECT WASTE DR DUPLEX RECEPTACLE 8. PLUMBER TO SUPPLY AND INSTALL BACK-FLOW PREVENTERS ON ALL IW INDIRECT WASTE CP CORD AND PLUG ® FUNNEL FLOOR DRAIN EQUIPMENT AS REQUIRED BY LOCAL CODES. FD FLOOR DRAIN SW SWITCH SCALE FFD FUNNEL FLOOR DRAIN HP HORSE POWER El FUNNEL FLOOR SINK 9. PLUMBER TO COMPLETELY INSTALL ALL HAND SINKS, FAUCETS, (22" x 34}"� 1/4" = 1'-O" ® (11" x 17") "=1'-O" FS FLOOR SINK KW KILOWATTS LEVER/TWIST DRAINS, AS PROVIDED BY K.E.C. G GAS V VOLTAGE 10. PLUMBER TO INSTALL VACUUM BREAKERS FOR ALL COFFEE AND BTU BRITISH THERMAL UNIT GU GENERAL USE El ELONGATED FUNNEL FLOOR SINK ICE MAKERS. DRAWING S STEAM RECEP. RECEPTACLE 11. PLUMBER TO SUPPLY AND INSTALL ANY REQUIRED GREASE TRAP OR OR CONDENSATE RETURN AFF ABOVE FINISHED FLOOR RECEPTOR AS MAY BE REQUIRED BY LOCAL CODES. SEE PLUMBING D I N ETT E LP LIQUID PROPANE EOF ELECTRICAL OUTLET IN FLOOR TYPICAL SINK/DRAIN DETAILS SPCFM STATIC PRESSURE ENGINEERING DRAWINGS BY OTHERS FOR DETAILS AND SPECIFICATIONS. CUBIC FEET PER MINUTE BTC BRANCH TO CONNECT 12.PLUMBER TO INSTALL SHUT-OFF VALVE IN MAIN CAS LINE FOR FIRE PLUM B I N G PLAN SP DFA DOWN FROM ABOVE EXTINGUISHING SYSTEM. VALVE PROVIDED BY K.E.C. PSI POUNDS PER SQUARE INCH DOW OUT OF WALL ID HVAC HEATING/VENTILATING CONTRACTOR ID INSIDE DIAMETER y 13.PLUMBER TO INSTALL FLEXIBLE QUICK DISCONNECTS, IF SUPPLIED r EC ELECTRICAL CONTRACTOR IPS IRON PIPE SIZE I r1 BY K.E.C. (WHEN REQUIRED). KEC KITCHEN EQUIPMENT CONTRACTOR OD OUTSIDE DIAMETER r C I,�t.�i - 14.PLUMBING DRAIN LINES FOR WALK-INS BY K.E.C. REMOTE LOWBOYS GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MINUTE ! �..� J BY OTHERS. F a PC PLUMBING CONTRACTOR FP FIRE PULL BOX I15. DRAWING NUMBER NIC NOT IN CONTRACT SO SMOKE DETECTOR L I IF LOCAL CODE OR CONSTRUCTION DOCUMENTS MANDATE PITCHING TO FLOOR _ DRAINS AND/QR FLOOR SINKS IT MUST BE NOTED THAT EQUIPMENT MIGHT ; �� J. I. v/7_ WC WATER COLUMN AV AUDIO VISUAL DEVICE NEED TO BE MODIFIED IN THE FIELD TO ACCOMMODATE THIS PITCHING. CWS COLD WATER SUPPLY NG NATURAL GAS C R COLD WATER RETURN F ,,. �A fir'. 1 084 A'�0 _S.10�/ PLUMBING SCHEDULE z z z z z 0 Of co = Oz ,v oZ Oz v 3 NW CnLL _jW [--W F-2 WLLI �W ITEM <N m QL, ON -3:Et ON Oa_ � L N OLD ON cc NO QTY EQUIPMENT CATEGORY MANUFACTURER MODEL NUMBER ocn 0< C)cn 0< =cn I=0 =Q oin oQ Zcn PLUMBING REMARKS CD Q 1 1 UNDERBAR 3 COMPARTMENT SINK KROWNE KR19-53C - - - 0.5 14 0.5 - 14 - - 1.5 IW TO FS o 1.1 3 SINK COVER DIAMOND GROUP SC-14X10 - - - - - - - - - - - F77'- 0 2 1 UNDERCOUNTER REFRIGERATION PERLICK HD24RS4 - - - - - - - - - - - - 3 1 MILLWORK COUNTER & DIE WALL BY OTHERS N/A - - - - - - - - - - - - - c 0 4 1 MILLWORK STORAGE BY OTHERS N/A a 5 1 UNDERBAR ICE CHEST KROWNE KR19-18 - - - - - - - - - - 1.0 IW TO FS a� 5.1 1 UNDERBAR SPEED RAIL KROWNE RS-18 - - - - - - - - - - - - E 6 1 UNDERCOUNTER REFRIGERATION, ADA PERLICK HB24WS4 - - - - - - - - - - - - 7 1 MILLWORK REMOVABLE ADA COUNTER BY OTHERS N/A - - - - - - - - - - - - y 8 1 MILLWORK COUNTER & DIE WALL BY OTHERS N/A - - - - - - - - - - - - P i 9 1 POS STATION W/ PRINTER BY OWNER N/A 1177 - 10 1 DRINK RAIL BY OTHERS DR-5X122 - - - - - - - - - - 1.0 IW TO FS; VERIFY IW QNTY W/ FAB. DRAWINGS 0 11 1 OPEN NUMBER 12 1 UNDERCOUNTER REFRIGERATION, ADA PERLICK HB24WS4 2 13 1 EXHAUST HOOD ASSEMBLY CAPTIVE AIRE EXHAUST HOOD 13.1 1 FIRE SUPPRESSION SYSTEM INTERSTATE FIRE & SAFETY ANSUL - - - - - - - - - - - - 13.2 1 HOOD CONTROL PANEL CAPTIVE-AIRE CONTROL PANEL - - - - - - - - - - - - (77 _ '2 13.3 1 ANSUL PULL STATION INTERSTATE FIRE & SAFETY ANSUL 0 13.4 1 THERMISTOR, 1.8K SENSOR OUTPUT, LCD DISPLAY AUTOMATION COMPONENTS, INC. A/1.8K-R-LCD-F (124245) - - - - - - - - - - - - 14 1 1 OVEN, FINISHING EQUIPEX SEM-60VC 15 1 JELECTRIC COOKING SUITE ATHANOR E-SUITE - - - 0.5 4 - - - - - 1.5 IW TO FS; CW STUB-UP; PENDING ATHANOR SHOP DRAWINGS FOR EXACT STUB-UP LOCATIONS Y '""""' '"""" w 16 1 ITUBULAR OVERSHELF ADVANCE TABCO DT21-8 - - - - - - - - - - - - - _ ,_ s 17 1 REFRIGERATOR, UNDERCOUNTER BEVERAGE-AIR UCRD72AHC-6 - - - - - - - - - - - - 1 Q 18 1 UNDERBAR FILLERS & DRAINBOARDS GLASTENDER DBCA-18-LD - - - - - - - - - - 1.5 IW TO FS 0 19 1 OPEN NUMBERcu - - - - - - - - - - - - - - j 3 20 1 OPEN NUMBER - - - - - - - - - - - - - - u, 21 1 OPEN NUMBER - - - - - - - - - - - - - - 22 2 HEAT LAMP, DECORATIVE HATCO DLH-725-ASR - - - - - - - - - - - - h $ U 22.1 1 REMOTE SWITCH FOR HEAT LAMP HATCO DL-SWITCH-16AMP 23 1 ESPRESSO MACHINES, AUTOMATIC - GROUP 1 LA MARZOCCO LINEA CLASSIC S 1 AV 1 10.375 50 - - - - - 1.0 IW TO FS; INTERCONNECTED TO WATER FILTER (ITEM #26) ,. 24 1 OPEN NUMBER - - - - - - - - - - - - - - 25 1 REFRIGERATOR, REACH-IN CONTINENTAL REFRIGERATOR 1 RN - - - - - - - - - - - - 36 East 31 st Street, 6th Floor 26 1 WATEIR FILTER EVERPURE EV433991 - - - 0.75 26 - - - - - - PLUMBER TO PROVIDE BYPASS LINE; INTERCONNECTED TO ITEM #23 New York, New York 10016 26.1 1 WATER FILTER EVERPURE EV9293-01 - - - 0.75 26 - - - - - - PLUMBER TO PROVIDE BYPASS LINE; INTERCONNECTED TO ITEM #45 Tel: (212)244-0008 27 1 WAREWASHER, UNDERCOUNTER, HIGH TEMP ECOLAB E-UHT - - - 0.75 10 0.75 - 10 - - 1.0 IW TO FS; CW CONN. FOR DRAIN WATER TEMPERING KIT TO BE INSTALLED BY P.C.; INCOMING WATER TEMP. 110-155 DEGREES F. 28 1 1 COFFEE GRINDER LA MARZOCCO USA MAZZER ROBUR E GRINDER - - - - - - - - - - - - Fax: (212)244-0057 29 1 OPEN NUMBER - - - - - - - - - - - - - - emall: jkouveras@samtell.Com 30 1 OPEN NUMBER - - - - - - - - - - - - - 31 1 OPEN NUMBER - - - - - - - - - - - - - - 32 1 OPEN NUMBER - - - - - - - - - - - - - - RELEASE 8 IREV. CONCEPT DESIGN 12-12-2022 DE 33 4 SHELVING, WIRE METRO MQ2436G - - - - - - - - - - - - 9 DESIGN DEVELOPMENT 12-13-2022 DE 34 1 TRASH RECEPTACLE, "SLIM JIM" CARLISLE 342023-03 - - - - - - - - - - - - 10 MEP SUBMISSION 12-23-2022 AO 35 1 CHEF'S PASS TABLE DIAMOND GROUP CHPT-30X111 - - - 0.5 10 0.5 - 10 1.5 10 - - 11 MEP SUBMISSION 12-28-2022 AO 35.1 1 HAND SINK SIDE SPLASH DIAMOND GROUP HS-SS - - - - - - - - - - - - 12 MEP SUBMISSION 01-03-2023 AO 36 1 OPEN NUMBER - - - - - - - - - - - - - - 13MEP SUBMISSION 01-05-2023 AO 37 1 MOP SINK CABINET REGENCY 600SMC25SD - - - 0.5 42 0.5 - 42 2.0 3 - 2" DIAMETER DW STUB UP 14 OYSTER BAR CONCEPT 01-19-2023 DE 38 1 MILLWORK COUNTER BY OTHERS N/A - - - - - - - - - - - - 15 OYSTER BAR REVISIONS 01-25-2023 KK 39 1 MOP BUCKET BY OTHERS N/A - - - - - - - - - - - - 16 OYSTER BAR REVISIONS 01-31-2023 DE 40 1 OPEN NUMBER - - - - - - - - - - m - - - 17 OYSTER LOBBY BAR MEP 02-10-2023 DE 41 1 OPEN NUMBER - - - - - - - - - - - - - 18 BACKGROUND UPDATE 02-24-2023 DE 42 1 POS STATION W/ PRINTER BY OWNER N/A - - - - - - - - - - - 19 DINETTE MEP SCHEDULES 02-27-2023 DE 43 1 SINK, DROP-IN EAGLE GROUP/METAL MASTERS SR10-14-5-1 - - - 0.5 18 0.5 - 1816 - - DOH SUBMITTAL 03-02-2023 DE 43.1 2 HAND SINK SIDE SPLASH DIAMOND GROUP HS-SS (19X6) - - - - - - - - - - - 21,DOH SUBMITTAL UPDATE 03-09-2023 DE 44 1 PITCHER RINSER RHINO RHPR300 - - - 0.5 18 - - - - - 1.0 IW TO FS 2 MEP DOCUMENTATION 03-10-2023 DE 45 1 COFFEE MAKER, INSULATED SERVER, AUTOMATIC FETCO CBS-1131V+ - - - 0.375 50 - - - - - - INTERCONNECTED TO WATER FILTER (ITEM #26.1) 2 CLARIFICATIONS 03-16-2023 DE 46 1 SINK, DROP-IN EAGLE GROUP/METAL MASTERS SR14-16-9.5-1 - - - 0.5 14 0.5 - 14 - - 1.5 IW TO FS DOH SUBMITTAL UPDATE 03-27-2023 DE 47 1 KNOCKBOX VOLLRATH E06064-KB - - - - - - - - - - - - DOH UPDATE, PART 2 03-31-2023 DE 48 1 TRASH RECEPTACLE, "SLIM JIM" CARLISLE 342023-03 - - - - - - - - - - - - 26 MEP UPDATE 04-05-2023 DE 49 1 OPEN NUMBER - - 27 BOATHOUSE UPDATE 04-21-2023 DE - - - - - - - - - - - - DINETTE UPDATE 04-28-2023 DE 50 1 OPEN NUMBER - - - - - - - - - - - - - - 9 BOATHOUSE UPDATE 06-09-2023 DE 51 1 OPEN NUMBER - - - - - - - - - - - - - - 52 1 OPEN NUMBER - - - - - - - - - - - - - - PROJEtCT 53 1 UNDERCOUNTER REFRIGERATION, ADA PERLICK HB24RS4 - - - - - - - - - - - - 54 1 MILLWORK COUNTER BY OTHERS N/A - - - - - - - - - - - - 55 1 FREEZER, UNDERCOUNTER HOSHIZAKI AMERICA JEUF27A - - - - - - - - - - - - m I� n PLUMBING SYMBOLS LEGEND GENERAL PLUMBING NOTES 3 1. ALL WORK DONE IN ACCORDANCE WITH ALL LOCAL CODES. • HW, CW, DIRECT DRAIN STUB UP �c 2. ALL WATER LINES TO HAVE SHUT-OFF VALVE. 3. PLUMBER TO PROVIDE DISHWASHER HOT WATER AT 140'F MINIMUM ��,� B GAS CONNECTION STUB UP CONSTANT SUPPLY. `"!'!'? 10 4 DIRECT STEAM CONNECTION 4. ALL INTERCONNECTING AND FINAL CONNECTIONS BY PLUMBER. 0 _ 0 CONNECTION 5. SEE PLUMBING ENGINEERING PUNS BY OTHERS FOR COMPLETE SCOPE OF WORK AND PLUMBING SPECIFICATIONS. ABBREVIATIONS El FLOOR SINK WITH HALF GRATE 6. THE HOT WATER HEATER TO BE SIZED TO MAXIMUM USE DEMANDS OF ALL PLUMBING FIXTURES. HW HOT WATER 140 JB JUNCTION BOX ® FLOOR DRAIN 7. PLUMBER TO PIPE DRAINS FROM WALK-IN COOLER/FREEZER CW COLD WATER SR SINGLE RECEPTACLE EVAPORATOR UNITS TO OPEN SITE DRAIN. USE COPPER PIPE ONLY. OW DIRECT WASTE OR DUPLEX RECEPTACLE B. PLUMBER TO SUPPLY AND INSTALL BACK-FLOW PREVENTERS ON ALL IW INDIRECT WASTE CP CORD AND PLUG ® FUNNEL FLOOR DRAIN EQUIPMENT AS REQUIRED BY LOCAL CODES. FD FLOOR DRAIN SW SWITCH SCALE FFD FUNNEL FLOOR DRAIN HP HORSE POWER FUNNEL FLOOR SINK 9. PLUMBER TO COMPLETELY INSTALL ALL HAND SINKS, FAUCETS, N.T.S. FS FLOOR SINK KW KILOWATTS LEVER/TWIST DRAINS, AS PROVIDED BY K.E.C. ` G GAS V VOLTAGE 10.PLUMBER TO INSTALL VACUUM BREAKERS FOR ALL COFFEE AND v BTU BRI11SH THERMAL UNIT GU GENERAL USE ® ELONGATED FUNNEL FLOOR SINK ICE MAKERS. c DRAWING S STEAM RECEP. RECEPTACLE it.PLUMBER TO SUPPLY AND INSTALL ANY REQUIRED GREASE TRAP OR CR CONDENSATE RETURN AFF ABOE FINISHED FLOOR V RECEPTOR AS MAY BE REQUIRED BY LOCAL CODES. SEE PLUMBING DIN ETTIE LP UQUID PROPANE EOF ELECTRICAL OUTLET IN FLOOR TYPICAL SINK/DRAIN DETAILS ENGINEERING DRAWINGS BY OTHERS FOR DETAILS AND SPECIFICATIONS. CFMCUBIC FEET PER MINUTE BTC BRANCH TO CONNECT SP STATIC PRESSURE 12. PLUMBER TO INSTALL SHUT-OFF VALVE IN MAIN GAS LINE FOR FIRE PLUMBING SCHEDULE SP DFA DOWN FROM ABOVE EXTINGUISHING SYSTEM. VALVE PROVIDED BY K.E.C. PSI POUNDS PER SQUARE INCH COW OUT OF WALL HVAC HEATING/VENTILATING CONTRACTOR ID INSIDE DIAMETER r-T " 13. PLUMBER TO INSTALL FLEXIBLE QUICK DISCONNECTS, IF SUPPLIED EC ELECTRICAL CONTRACTOR IPS IRON PIPE SIZE F I r BY K.E.C. (WHEN REQUIRED). KEC KITCHEN EQUIPMENT CONTRACTOR OD OUTSIDE DIAMETER 1 , 14. PLUMBING DRAIN UNES FOR WALK-INS BY K.E.C. REMOTE LOWBOYS GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MINUTE BY OTHERS. `E f Nt PC PLUMBING CONTRACTOR FP FIRE PULL BOX 477 " DRAWING NUMBER NIC NOT IN CONTRACT SD SMOKE DETECTOR 15.1E LOCAL CODE OR CONSTRUCTION DOCUMENTS MANDATE PITCHING TO FLOOR J DRAINS AND/QR FLOOR SINKS IT MUST BE NOTED THAT EQUIPMENT MIGHT .µ �N CO Q7 WC WATER COLUMN AV AUDIO VISUAL DEVICE - NEED TO BE MODIFIED IN THE FIELD TO ACCOMMODATE THIS PITCHING. CWS COLD WATER SUPPLY NG NATURAL GAS t ppp R COLD WATER RETURN " y ,.:.� s Fr,1 ._ .z v N N a O 9 4 — CL � m CD a� U c .Q �nwnsa O U O 3 0 a .._.._.._.._•- -- ____- ---- .._.. --------------------- ----------------- -- -- cn -------- -- -- ----- ----- jll o �. w 0 II H: 1 I j' 3'-10" 4" Fr -- -1, oopoao 00 000o e,o o e o o�ea000 2—3y4 I I _ a _ c I I II ' Ji j ' II I ' I ; J' I I _i 5-8n I I I' --� I ,,. i I .,,a i I v _ j E_= 36 East 31st Street, 6th Floor b I L_ ------------ __ __— -_.._'--- I I� New York, New York 10016 n.. _I_ _ .M-_..... ..._X-m.-w_..,. _. ...... �..._..-,.. 2'-�" �_= Tel: (212)244-0008 --- i Fax: (212)244-0057 email: jkouveras Dz samtell.com , _— �--------------�---�--�----- ------- —=_--- =—�—= — RELEASE 8 REV. CONCEPT DESIGN 12-12-2022 DE , I• =I;J, 9 DESIGN DEVELOPMENT 12-13-2022 DE 10 MEP SUBMISSION 12-23-2022 AO I ! 11 MEP SUBMISSION 12-28-2022 AO 12 MEP SUBMISSION 01-03-2023 AO 2.0'DIADW STUB UP 13 MEP SUBMISSION 01-05-2023 AO 14 OYSTER BAR CONCEPT 01-19-2023 DE 15 OYSTER BAR REVISIONS 01-25-2023 KK i it 16 OYSTER BAR REVISIONS 01-31-2023 DE 170YSTER LOBBY BAR MEP 02-10-2023 DE � I 18 BACKGROUND UPDATE 02-24-2023 DE ------J 19 DINETTE MEP SCHEDULES 02-27-2023 DE DOH SUBMITTAL 03-02-2023 DE I €� j 1 DOH SUBMITTAL UPDATE 03-09-2023 DE MEP DOCUMENTATION 03-10-2023 DE 6'-4" 21 CLARIFICATIONS 03-16-2023 DE I 24 DOH SUBMITTAL UPDATE 03-27-2023 DE 3' 4'-8" I 25 DOH UPDATE, PART 2 03-31-2023 DE I I 26 MEP UPDATE 04-05-2023 DE BOATHOUSE UPDATE 04-21-2023 DE 1'-2" '' _ ` II - i I DINETTE UPDATE 04-28-202,31 DE I 9 BOATHOUSE UPDATE 106-09-20231 DE 1 I PROJECT en Pi 1 1 G5 i 1 1 i PLUMBING SYMBOLS LEGEND GENERAL PLUMBING NOTES 1. ALL WORK DONE IN ACCORDANCE WITH ALL LOCAL CODES. • HW, CW, DIRECT DRAIN STUB UP 2• ALL WATER LINES TO HAVE SHUT-OFF VALVE. ¢ ■ ""'� l�-: GAS CONNECTION STUB UP 3. PLUMBER TO PROVIDE DISHWASHER HOT WATER AT 140'F MINIMUM �■■� CONSTANT SUPPLY. 06 DIRECT STEAM CONNECTION 4. ALL INTERCONNECTING AND FINAL CONNECTIONS BY PLUMBER. O CONNECTION 6. SEE PLUMBING ENGINEERING PLANS BY OTHERS FOR COMPLETE SCOPE OF WORK AND PLUMBING SPECIFICATIONS. ABBREVIATIONS E] FLOOR SINK WITH HALF GRATE 6. THE HOT WATER HEATER TO BE SIZED TO MAXIMUM USE DEMANDS OF ALL PLUMBING FIXTURES. HW HOT WATER 140 JB JUNCTION BOX ® FLOOR DRAIN 7. PLUMBER TO PIPE DRAINS FROM WALK—IN COOLER/FREEZER CW COLD WATER SR SINGLE RECEPTACLE EVAPORATOR UNITS TO OPEN SITE DRAIN. USE COPPER PIPE ONLY. c DW DIRECT WASTE DR DUPLEX RECEPTACLE IW INDIRECT WASTE ® FUNNEL FLOOR DRAIN 8. PLUMBER TO SUPPLY AND INSTALL BACK-FLOW PREVENTERS ON ALL /+ FD FLOOR DRAIN CP CORD AND PLUG EQUIPMENT AS REQUIRED BY LOCAL CODES. SCALE SW SWITCH FFD FUNNEL FLOOR DRAIN HP HORSE POWER FUNNEL FLOOR SINK 9. PLUMBER TO COMPLETELY INSTALL ALL HAND SINKS, FAUCETS, (22" x 34") 1/4" = 1'-0" ® (11" x 17") "=1'-0" FS FLOOR SINK KW KILOWATTS LEVER/TWIST DRAINS, AS PROVIDED BY K.E.C. G GAS V VOLTAGE 10. PLUMBER TO INSTALL VACUUM BREAKERS FOR ALL COFFEE AND GU GENERAL USE BTU BRITISH THERMAL UNIT ELONGATED FUNNEL FLOOR SINK ICE MAKERS. DRAWING S STEAM RECEP. RECEPTACLE CR CONDENSATE RETURN 11. PLUMBER TO SUPPLY AND INSTALL ANY REQUIRED GREASE TRAP OR LIQUID PROPANE ^FF ABOVE FINISHED FLOOR RECEPTOR AS MAY BE REQUIRED BY LOCAL CODES. SEE PLUMBING LP DINETTE CFMLP CUBIC FEET PER MINUTE EOF ELECTRICAL OUTLET IN FLOOR TYPICAL SINK/DRAIN DETAILS ENGINEERING DRAWINGS BY OTHERS FOR DETAILS AND SPECIFICATIONS. BTC BRANCH TO CONNECT 12. PLUMBER TO INSTALL SHUT-OFF VALVE IN MAIN GAS LINE FOR FIRE DFA M A FLOOR DRAIN/SINK PLAN SP STATIC PRESSURE DOWN FROM EXBNGUISHING SYSTEM. VALVE PROVIDED BY K.E.C. PSI POUNDS PER SQUARE INCH OOW OUT OF WALL HVAC HEATING/VENTILATING CONTRACTOR ID INSIDE DIAMETER ' 13. PLUMBER TO INSTALL FLEXIBLE QUICK DISCONNECTS, IF SUPPLIED EC ELECTRICAL CONTRACTOR IPS IRON PIPE SIZE 7 I--I BY K.E.C. (WHEN REQUIRED). KEC KITCHEN EQUIPMENT CONTRACTOR OD OUTSIDE DIAMETER ern r I 14. PLUMBING DRAIN LINES FOR WALK-INS BY K.E.C. REMOTE LOWBOYS GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MINUTEIIr �^ BY OTHERS. PC PLUMBING CONTRACTOR I DRAWING NUMBER P�� F IV FP FIRE PULL BOX L 1'1«. 15.IF LOCAL CODE OR CONSTRUCTION DOCUMENTS MANDATE PITCHING TO FLOOR f�\ NIC NOT IN CONTRACT SO SMOKE DETECTOR DRAINS AND/OR FLOOR SINKS IF MUST BE NOTED THAT EQUIPMENT MIGHT _ WC WATER COLUMN AV AUDIO VISUAL DEVICE — NEED TO BE MODIFIED IN THE FIELD TO ACCOMMODATE THIS PITCHING. C-) �N C � \\ CWS COLD WATER SUPPLY y Vn NG NATURAL GAS C R COLD WATER RETURNa _ .., v.._....-....._..,._... ...,.._. ,- .....:.- ..�. ..� * ;� r'� 0� .0 — % 05 v� ' a U N C� CL Q (6 .3 a� , U C a U O 10 3 3 o ---------------------- F E �- -- � -- r ------- -" -- °'o I , N o A , I ' " _-_------ - - iI � i c3Oy---------------------------- cz - Cm �------j o J HOOD LOCATION ' ' 36 East 31st Street, 6th FloorG.C.TO PROVIDE STRUCTURAL STEEL TO I L_ HANG HOOD -- (MAY AFFECT REFLECTED CEILING PLAN) New York, New York 10016 WALL BLOCKING REQUIRED FOR V-8"@2'-6" Tel: (212)244-0008 j r� �j 6 ANSULMOOD CONTROLS (ITEM#13.1113.2)FROM T6"-108"AFF i FIRE RETARDANT WALL I Fax: 212)244-0057 BLOCKING REQUIRED I Ij email: jkouveras@samtell.com -------------- --=-----=-- - ==--- ----- -: z�� - RELEASE -�� 8 IREV. CONCEPT DESIGN 12-12-2022 DE 9 DESIGN DEVELOPMENT 12-13-2022 DE 10 MEP SUBMISSION 12-23-2022 AO 11 MEP SUBMISSION 12-28-2022 AO 12 MEP SUBMISSION 01-03-2023 AO 13 MEP SUBMISSION 01-05-2023 AO �= 14 OYSTER BAR CONCEPT 01-19-2023 DE 15 OYSTER BAR REVISIONS 01-25-2023 KK 16 OYSTER BAR REVISIONS 01-31-2023 DE 170YSTER LOBBY BAR MEP 02-10-2023 DE 18 BACKGROUND UPDATE 02-24-2023 DE ------J 19 DINETTE MEP SCHEDULES 02-27-2023 DE I I DOH SUBMITTAL 03-02-2023 DE I I ---- 1 DOH SUBMITTAL UPDATE 03-09-2023 DE I I I 10'—SY2" 2'-4" 2 MEP DOCUMENTATION 03-10-2023 DE I 2 CLARIFICATIONS 03-16-2023 DE WALL BLOCKING REQUIRED FOR UNDER COUNTER WATER TE (ITEM#26&26.1)FROM 12"-36FIL"AF RS F i DOH SUBMITTAL UPDATE 03-27-2023 DE DOH UPDATE, PART 2 03-31-2023 DE MEP UPDATE 04-05-2023 DE - - - - - - - - - - - - - - - - - - - - - - - - - 27 BOATHOUSE UPDATE 04-21-2023 DE r- -- -- -- -- -- -- -- -- -- -- -- -- — -- -- -- -- -- -- -- ----- -- - -- -- -- -- -- -- -- -- -- -- -- -- -- DINETTE UPDATE 04-28-2023 DE 28 , i 9 BOATHOUSE UPDATE 1 06-09-20231 DE , PROJECT , , i i I WALLBLOCKING TO BE 16 GAUGES SODA&BEER SYSTEM NOTES WALLBLOCKING DETAILS: NO SCALE GALVANIZED METAL OR 3/4" (19MM) r PLYWOOD. LOCATIONS REQUIRING FIRE RETARDANT BLOCKING NOTED 1. VERIFY LINE SIZES, RUNS, STUB LOCATIONS & CONNECTION LOCATIONS WITH THE ON PLAN, INCLUDING AREAS BELOW SPECIAL CONDITIONS NOTES if SODA SYSTEM CONTRACTOR. EXHAUST HOODS (REGARDLESS OF USE). ALL WALLBLOCKING SHALL BE �e 2. VERIFY LINE SIZES, RUNS, STUB LOCATIONS & CONNECTION LOCATIONS WITH THE CONCEALED AND SECURELY ATTACHED ,� TO WALL FRAMING WITHIN WALLS 1. GENERAL CONTRACTOR SHALL INSURE ALL WALLS/CEILINGS ARE PROPERLY '» BEER SYSTEM CONTRACTOR. (BEHIND GYP. BOARD AND/OR REINFORCED TO SUPPORT ALL WALL AND/OR CEILING SUPPORTED � P, 3. WHEN USING CONDUIT TO RUN LINES ALL CONDUIT TURNS MUST BE MINIMUM 24" FINISHES) EQUIPMENT. RADIUS SWEEPING TURNS. 2' BLOCKING 2. GENERAL CONTRACTOR TO PROVIDE BRIDGING TO BUILDING STRUCTURE ¢ c r 2,-6- AREWAL MINIMUM. ALWAYS LENGTHS SHOWN ABOVE FOR EXHAUST HOODS. 1- 6- ARE TO NEXT STU EXTEND �V 3. GENERAL CONTRACTOR SHALL VERIFY INSTALLATION HEIGHT OF FINISHED 2- B. IN EACH DIRECTION CEILING WITH FOOD SERVICE EQUIPMENT BELOW AS SHOWN. 0 2"-6" 4. MASONRY BASE REQUIRED - BY GENERAL CONTRACTOR ALL RALLBLOC RAC TO BE BY ABBREVIATIONS GENERAL CONTRACTOR UNLESS 6. GENERAL CONTRACTOR SHALL PROVIDE 6" (150mm) DIA. RACEWAY AND 4"-6- 4"-6" OTHERWISE NOTED CORE DRILLING TO RUN SODA AND BEER LINES - BY VENDOR 3'-8" ALL BENDS TO BE EASY SWEEPS (18" (450mm) RADIUS MIN.)GENERAL HW HOT WATER 140 JB JUNCTION BOX 3-4" " ANY SITES SPECIFIC CONDITIO S CONTRACTOR TO RUN FROM SODA AND BEER SYSTEM(S) TO POINT(S) CW COLD WATER SHOWN FOR SODA HEADS. RUN CONDUIT ON UNDERSIDE OF SLAB OR DW DIRECT WASTE SR SINGLE RECEPTACLE THAT REQUIRE DEVIATION FRO ABOVE FINISHED CEILING AS INDICATED AND PROVIDE SUPPORT AS DR DUPLEX RECEPTACLE THESE INSTRUCTIONS, AND NOT REQUIRED, IW INDIRECT WASTE CP CORD AND PLUG COVERED IN PLAN NOTES, MUST FD FLOOR DRAIN 1 DGLISLE 2 HAND SINKS& 3 SINGLE OVERSHELF 4 POT SHELVES Fj PRE-RINSE �ATER TYPICAL BE COORDINATED WITH KEC, (FOOD 6. GENERAL CONTRACTOR SHALL PROVIDE 2"(50mm)DIA. RACEWAY(PVC, SCALE FFD FUNNEL FLOOR DRAIN SW SWITCH OVERSHELVE, & MOP SINKS (TOP TIER) &DISH RACKS AUCET BRACKET FILTER FACILITIES DESIGN CONSULTANT) EMT OR OTHER MATERIAL REQUIRED BY CODE) FOR RUN OF COMPUTER HP HORSE POWER HOTLINE TVB". PRIOR TO COMMENCEMENT OF WORK GRADE CONDUIT. ALL BENDS TO BE EASY SWEEPS(18' (450mm) RADIUS (22" X 34'") 1/4" = 1"-0" ® (11" X 17") A"=1"-0" FS FLOOR SINK KW KILOWATTS OVERSHFLVFS CORNER GUARDS ARE TO BE 18 - 20 GAUGE S/S, FLOOR CONDITIONS MIN.) AS REQUIRED BY OWNER. G GAS V VOLTAGE 2' X 2", AND SECURED IN THE FOLLOWING MANNER: BTU BRITISH THERMAL UNIT RECEPGU GENERAL USE. RECEPTACLE CLEARANCE ON EACH SIDE AND TOP(S)7. GENERAL CONTRACTOR SHALL PROVIDE CLEAR OPENING IN WALL TO DRAWINGS STEAM CORNER GUARDS SECURED TO S/S SURFACE RECEIV AFF ABOVE FINISHED FLOOR E FOOD SERVICE EQUIPMENT BY K.E.C. CONTRACTOR TO ALLOW Yi CR CONDENSATE RETURN ARE SECURED WITH "POP" RIVETS AND EDGES OF UNIT(S). LP LIQUID PROPANE SILICONED. CORNER GUARDS TO BEGIN AT - FLOOR DINETTE EOF ELECTRICAL OUTLET IN FLOOR 8. GENERAL CONTRACTOR SHALL PROVIDE STEEL BRIDGING FOR REMOTE CFM CUBIC FEET PER MINUTE BTC BRANCH TO CONNECT TOP OF SANITARY COVED MOLDING AND EXTEND DEPRESSION COMPRESSORS AT REMOTE LOCATION. SP STATIC PRESSURE TO A MINIMUM OF 48" AFF DEPTH - TBD SPECIAL CONDITIONS PLAN DFA DOWN FROM ABOVE 8 9. REFRIGERATION CONTRACTOR TO INTERCONNECT REFRIGERATION LINES FROM PSI POUNDS PER SQUARE INCH S/S WALL CLADDING OOW OUT OF WALL CORNER GUARDS SECURED TO FRP SURFACE REMOTE COMPRESSORS TO EVAP. COILS IN REFRIGERATORS, COOLERS, AND FREEZERS. HVAC HEATING/VENTILATING CONTRACTOR ID INSIDE DIAMETER ARE SECURED WITH CONTACT CEMENT AND LLLLLL - RAISED CURB EC ELECTRICAL CONTRACTOR EDGES SILICONEp L L 10. REFRIGERATION SUPPLY AND RETURN LINES. GENERAL CONTRACTOR TO IPS IRON PIPE SIZE S/S WALL CLADDING SECURED TO COORDINATE WITH THE K.E.C. AND REFRIGERATION CONTRACTORS. KEC KITCHEN EQUIPMENT CONTRACTOR OD OUTSIDE DIAMETER WALL SURFACE WITH CONTACT GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MNUTE CORNER GUARDS ARE TO BE SUPPLIED _ CEMENT TRIM STRIPS AND EDGES 11. GENERAL CONTRACTOR TO PROVIDE CORE DRILLING AND THERMAL BARRIER PC PLUMBING CONTRACTOR AND INSTALLED BY THE KEC SMOOTH & LEVEL ARE SILICONED AS REQUIRED FOR RECESSED COOLER FLOORING. DRAWING NUMBER FP FIRE PULL BOX FINISHED SURFACE NIC NOT IN CONTRACT SO SMOKE DETECTOR 7 GENERAL CONTRACTOR TO PROVIDE S/S WALL CLADDING & STRIPS 12.IF LOCAL CODE OR CONSTRUCTION DOCUMENTS MANDATE PITCHING TO FLOOR {/�� 0, rA, WC WATER COLUMN AV AUDIO VISUAL DEVICE TRUE, CONSISTANT 90' ANGLES TO TO BE SUPPLIED AND INSTALLED DRAINS AND/OR FLOOR SINKS IT MUST gE NOTED THAT EQUIPMENT MIGHT NEED \ - �✓ \ CWS COLD WATER SUPPLY NG NATURAL GAS S/S CORNER GUARDS FACILITATE CONER GUARD INSTALLATION BY THE GENERAL CONTRACTOR TO BE MODIFIED IN THE FIELD TO ACCOMMODATE THIS PITCHING. �. �-\ C R COLD ATER REIUR r .- cit- y -- - O O516 o p r U N Q .1� (6 U Q Q (6 i co t 3 (7'r C (6 y U F�, a O -c'-Q Em Lu A O � S 1 �.... ,' 1 I1 1 � 1 ICCI q O --- - 11 ------------------------- I ' I '1� 1 ITEM II ��,\ i '1 �------�I I 1 1 � 1 .. L #2 TEMPERATURE ---- ( I 1 SENSOR LOCATION II I I ! 1 1 1 u 3 ANSUL PULL STATION LOCATION -)I ; I o LOCATION OF I ITEM I ITEM ANSUL I L - - - - - - - � 9" 36 East 31st Street, 6th Floor _ _I--- I li New York, New York 10016 _=[p, Tel: (212)244-0008 ----------------- 4--3" Fax: (212)244-0057 ITEM I I Ij email: jkouveras@sanitell.com samtell.Com #12 I I - —JL - _ -------------- ------ __� - --- ----- - RELEASE 8 REV. CONCEPT DESIGN 12-12-2022 DE FOR CFM REQUIREMENTS,DUCT COLLAR ITEM I 9 IDESIGN DEVELOPMENT 12-13-2022 DE SIZES&ETC... #25 PLEASE REFERENCE CAPTIVE AIRE 10 MEP SUBMISSION 12-23-2022 AO FABRICATION DRAWINGS FS FAB(7.0)THROUGH FS FAB(1.'I) 11 EP SUBMISSION 12-28-2022 AO 12 MEP SUBMISSION 01-03-2023 AO 11-8" 11-10"1, 31-8" f 31-8" f V-10" 13 MEP SUBMISSION 01-05-2023 AO 14 OYSTER BAR CONCEPT 01-19-2023 DE 15 OYSTER BAR REVISIONS 01-25-2023 KK F 16 OYSTER BAR REVISIONS 01-31-2023 DE ITEM I #55 II 17 OYSTE:R LOBBY BAR MEP 02-10-2023 DE L — — Jl 18 BACKGROUND UPDATE 02-24-2023 DE -------' 19 DINETTE MEP SCHEDULES 02-27-2023 DE F- 20 DOH SUBMITTAL 03-02-2023 DE 1 DOH SUBMITTAL UPDATE 03-09-2023 DE MEP DOCUMENTATION 03-10-2023 DE 121 CLARIFICATIONS 03-16-2023 DE DOH SUBMITTAL UPDATE 03-27-2023 DE DOH UPDATE, PART 2 03-31-2023 DE MEP UPDATE 04-05-2023 DE ITEM - - - - - - - - - - - - I27 BOATHOUSE UPDATE 04-21-2023 DE r - -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- #53 I I ! 12qDINETTE UPDATE 04-28-2023 DE 9 BOATHOUSE UPDATE 06-09-2023 DE 1 ( PROJECT i 1 1 1 ! 0 I 1 1 1 1 1 0 ABBREVIATIONS R SINGLE R VENTILATION NOTES H V A C CW COLD *TER S SR S cw �' HW HOT WATER 140 SINGLE R BoxECEPTACLE (H E A T R E J E C T 1 0 N) DW DIRECT WASTE DR DUPLEX RECEPTACLE IW INDIRECT WASTE CP CORD AND PLUG FD FLOOR DRAIN SW SWITCH 1. ALL DIMENSIONS SHOWN ARE FROM FINISHED WALLS, FLOORS & COLUMNS. c J C H E D U L E SCALE FFD FUNNEL FLOOR DRAIN HP HORSE POWER FS FLOOR SINK KW KILOWATTS 2. ALL INTERCONNECTING & FINAL CONNECTIONS BY HVAC CONTRACTOR. _ (22" x 34") 1/4" = 1'-0" 0 (11" x 17") "=1'-0" GAS V VOLTAGE BTU BRITISH THERMAL UNIT 3. SEE MECHANICAL CORING COMMENTS ON SPECIAL CONDITION'S PLANS, DRAWING STEAM GU GENERAL USE FOR COMPLETE SCOPE OF WORK & SPECIFICATIONS. RECEP. RECEPTACLE ALL CORING BY OTHERS. Li � HVAC DINETTE CR CONDENSATE RETURN AFF ABOVE FINISHED FLOOR � = m REMARKS LP LIQUID PROPANE EOF ELECTRICAL OUTLET FLOOR MECHANICAL PLAN CFM CUBIC FEET PER MINUTE BTC BRANCH TO CONNECTT 2 0.16 350 — SP STATIC PRESSURE DFA DOWN FROM ABOVE 6 0.25 450 - PSI POUNDS PER SQUARE INCH COW OUT OF WALL HVAC HEATING/VENTILATING CONTRACTOR ID INSIDE DIAMETER EC ELECTRICAL CONTRACTOR IPS IRON PIPE SIZE 12 0.25 450 - KEC KITCHEN EQUIPMENT CONTRACTOR OD OUTSIDE DIAMETER 17 0.2 1350 - GC GENERAL CONTRACTOR RPM REVOLUTIONS PER MINUTE PC PLUMBING CONTRACTOR FP FIRE PULL BOX DRAWING N U h1I R E R NIC NOT IN CONTRACT SD SMOKE DETECTOR 25 0.25 1940 - / WC WATER COLUMN AV AUDIO VISUAL DEVICE 53 0.16 450 CWS COLD WATER SUPPLY NG NATURAL GAS ; CWR COLD ATER RETURN55 0.2 993 „l F j F 1684 ��fi£SSIONP�'F N Q cz cc �. (0 4-7 .3 _ o CD O o 1.7 o (V C I I N pp.1 +a N a a � En( i 'o I O .. � .. iE U I I _ � o U N I I I .8 Ill T 4 zu > l I o CL CL -- �� m @ I a � .,. e.- .... > 2 — — — — — — — — — — — — — T_ \\ \\\ i .r T I 36 East 31 st Street, 6th Floor �\ New York, New York 10016 �1 I Tel: (212)244-0008 NO REFRIGERATION Fax: (212)244-0057 II I email: jkouveras a samtell.com I - - - - RELE/A►SE 8 REV. CONCEPT DESIGN 12-12-2022 DE 9 DESIGN DEVELOPMENT 12-13-2022 DE ' 10 MEP SUBMISSION 12-23-2022 AO 11 MEP SUBMISSION 12-28-2022 AO 12 MEP SUBMISSION 01-03-2023 AO 13 MEP SUBMISSION 01-05-2023 AO 1 14 OYSTER BAR CONCEPT 01-19-2023 DE 15 OYSTER BAR REVISIONS 01-25-2023 KK 16 OYSTER BAR REVISIONS 01-31-2023 DE 17 OYSTER LOBBY BAR MEP 02-10-2023 DE \ / I 18 BACKGROUND UPDATE 02-24-2023 DE 19 DINETTE MEP SCHEDULES 02-27-2023 DE 2CDOH SUBMITTAL 03-02-2023 DE 1 DOH SUBMITTAL UPDATE 03-09-2023 DE ----------------- 22 MEP DOCUMENTATION 03-10-2023 DE - - - - 22 CLARIFICATIONS 03-16-2023 DE DOH SUBMITTAL UPDATE 03-27-2023 DE DOH UPDATE, PART 2 03-31-2023 DE MEP UPDATE 04-05-2023 DE 27 BOATHOUSE UPDATE 04-21-2023 DE DINETTE UPDATE 04-28-2023 DE 9 BOATHOUSE UPDATE 106-09-20231 DE PROJECT �- K Lu ABBREVIATIONS r-�z SPECIAL CONDITIONS NOTES HW HOT WATER 140 JB JUNCTION Box IWO CW COLD WATER SR SINGLE RECEPTACLE DW DIRECT WASTE 1. GENERAL CONTRACTOR SHALL INSURE ALL WALLS/CEILINGS ARE PROPERLY DR DUPLEX RECEPTACLE IW INDIRECT WASTE REINFORCED TO SUPPORT ALL WALL AND/OR CEILING SUPPORTED CID CORD AND PLUG EQUIPMENT. FD FLOOR DRAIN SW SWITCH ,e� S FFD FUNNEL FLOOR DRAIN �? HP HORSEPOWER 2. GENERAL CONTRACTOR TO PROVIDE BRIDGING TO BUILDING STRUCTURE FS FLOOR SINK i ABOVE FOR EXHAUST HOODS. G GAS KW KILOWATTS 3. GENERAL CONTRACTOR SHALL VERIFY INSTALLATION HEIGHT OF FINISHED BTU V VOLTAGE BRMSH THERMAL UNIT � GU GENERAL USE CEILING WITH FOOD SERVICE EQUIPMENT BELOW AS SHOWN. S STEAM CR CONDENSATE RETURN RE RECEPTACLE 0 4. MASONRY BASE REQUIRED — BY GENERAL CONTRACTOR LP LIQUID PROPANE AFF FF ABOVE FINISHED FLOOR EOF ELECTRICAL OUTLET IN FLOOR 5. GENERAL CONTRACTOR SHALL PROVIDE 6` (150mm) DIA. RACEWAY AND CFM CUBIC FEET PER MINUTE BTC BRANCH TO CONNECT CORE DRILLING TO RUN SODA AND BEER LINES — BY VENDOR SP STATIC PRESSURE DFA DOWN FROM ABOVE ALL BENDS TO BE EASY SWEEPS (18" (450mm) RADIUS MIN.) GENERAL PSI POUNDS PER SQUARE INCH COW OUT OF WALL CONTRACTOR TO RUN FROM SODA AND BEER SYSTEM(S) TO POINT(S) HVAC HEATING/VENTILATING CONTRACTOR ID INSIDE DIAMETER SHOWN FOR SODA HEADS. RUN CONDUIT ON UNDERSIDE OF SLAB OR EC ELECTRICAL CONTRACTOR 1 ABOVE FINISHED CEILING AS INDICATED AND PROVIDE SUPPORT As KEC KITCHEN EQUIPMENT CONTRACTOR IPS IRON PIPE SIZE REQUIRED. OD OUTSIDE DIAMETER �+ GC GENERAL CONTRACTOR SCALE 6. GENERAL CONTRACTOR SHALL PROVIDE 2" (50mm) DIA. RACEWAY(PVC, PC PLUMBING CONTRACTOR RPM REVOLUTIONS PER MINUTE EMT OR OTHER MATERIAL REQUIRED BY CODE FOR RUN OF COMPUTER SI' FIRE PULL BOX NIC NOT IN CONTRACT SD SMOKE DETECTOR (22" x 34") 1/2" = 1'-0" ® (11" x 17") J"=1'-0" GRADE CONDUIT. ALL BENDS TO BE EASY SWEEPS (18" (450mm) RADIUS WC WATER COLUMN AV AUDIO VISUAL DEVICE MIN.) AS REQUIRED BY OWNER. CWS COLD WATER SUPPLY 7. GENERAL CONTRACTOR SHALL PROVIDE CLEAR OPENING IN WALL TO CWR COLD WATER RETUR NG NATURAL GAS DRAWING RECEIVE FOOD SERVICE EQUIPMENT BY K.E.C. CONTRACTOR TO ALLOW Y4 CLEARANCE ON EACH SIDE AND TOP(S) OF UNIT(S). DINETTE 8. GENERAL CONTRACTOR SHALL PROVIDE STEEL BRIDGING FOR REMOTE REFRIGERATION P LA N COMPRESSORS AT REMOTE LOCATION. 9. REFRIGERATION CONTRACTOR TO INTERCONNECT REFRIGERATION LINES FROM REMOTE COMPRESSORS TO EVAP. COILS IN REFRIGERATORS, COOLERS, AND FREEZERS. REFRIGERATION NOTES 10. REFRIGERATION SUPPLY AND RETURN LINES. GENERAL CONTRACTOR TO 04, � 7 COORDINATE WITH THE K.E.C. AND REFRIGERATION CONTRACTORS. 1. VERIFY REFRIGERATION LINE SIZES, RUNS, STUB LOCATIONS do CONNECTION DRAWING NUMBER G' � r, oo fi 11. GENERAL CONTRACTOR TO PROVIDE CORE DRILLING AND THERMAL BARRIER LOCATIONS WITH REFRIGERATION CONTRACTOR. �O y AS REQUIRED FOR RECESSED COOLER FLOORING. 2. CORE HOLE FOR REFRIGERATION LINES TO BE INSTALLED BY OTHERS, NOT KEC. * � ' 12. IF LOCAL CODE OR CONSTRUCTION DOCUMENTS MANDATE PITCHING TO FLOOR ' DRAINS AND OR FLOOR SINKS IT MUST BE NOTED THAT EQUIPMENT MIGHT NEEDEL TO BE MODIFIED IN THE FIELD TO ACCOMMODATE THIS PITCHING. 751 �` I FO E34 S1%