Loading...
HomeMy WebLinkAbout49140-Z SvfF01�` o�D . cpGs Town of Southold 11/27/2023 a y� P.O.Box 1179 Irv- x l 53095 Main Rd 1 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44762 Date: 11/27/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1395 Henrys Ln,Peconic SCTM#: 473889 Sec/Block/Lot: 74.-1-10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/20/2023 pursuant to which Building Permit No. 49140 dated 4/19/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued'is: roof-mounted solar panels to existingsingle-family dwellingas s applied for. The certificate is issued to Otani,Robert of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49140 8/14/2023 PLUMBERS CERTIFICATION DATED 0ut on 0 Signature sufFnt TOWN OF SOUTHOLD �oo�° Keay BUILDING DEPARTMENT y z, TOWN CLERK'S OFFICE "oy • 0� 1 SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49140 Date: 4/19/2023 Permission is hereby granted to: Otani, Robert 211 Thompson St Apt 2-P New York, NY 10012 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 1395 Henrys Ln, Peconic SCTM #473889 Sec/Block/Lot# 74.-1-10 Pursuant to application dated 3/20/2023 and approved by the Building Inspector. To expire on 10/18/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector o��pF SO(/T�,ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 Jamesh southoldtownny.gov Southold,NY 11971-0959 Q �yCow 1`1,0c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Robert Otani Address: 1395 Henry's Lane city:Peconic st: New York zip: 11959 Building Permit#: 49140 Section: 74 Block: 1 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Element Energy LLC Electrician: Jamie Minnick License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 9.6 kw roof mounted solar energy system with 24 panels, 1 enphase combiner panel Notes: SOLAR SYSTEM Inspector Signature: Date: August 14, 2023 1395 henrys lane # # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ NSULATIOWCAAULKING [ ] FRAMING /STRAPPING [ ] FINAL �0(wv [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE LATION [ ] PRE C/O [ ] RENTAL REMA S: I (../ 9v (4 Q jG DATE ICI Y?7 INSPECTO 5 Ye-vi r( SOUTyO 1 13 i * # TOWN OF SOUTHOLD BUILDING DEPT. couHr+, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION PRE C/O [ ] RENTAL REMARKS: `o,r DATE � , tq,0113 INSPECTOR 4 4q 140 p EC E 0 V E Town of Southold SEP ,. 5 20 July 10th, 2023 Building Department Town Hall Annex Building Building Department 54375 Route 25 Town of Southold P.O. Box1179 , Southold, NY 11971 Subject: Roof Mounted.Solar. Panels..-at-the:Otani Residence 1395 Henrys Ln Peconic 'NY. 11959 To Town of Southold: I have reviewed the solar energy system installation in the subject topic July 10th, 2023. The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department, Town of Southold, New York. The solar panel installation is in compliance with the requirements of the 2020 Residential Code of New York State, the 2017 National Electric Code, SEI/ASCE 07-16 "Minimum Design Loads for Buildings and Other Structures", NFPA Standard 70 and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. Markings in accordance with Section 690.53 of the National Electrical Code are provided. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property and public welfare. 1 Sincere pF NEw James Deer _i; . iE Y S DEC" 260 Deer DriveRio Mattituck, NY 11952 \ �s ,`'•S 631-774-7355 m g9Iga Town of Southold July 10th, 2023 Building Department AUG TV 2023 Town Hall Annex Building 54375 Route 25 Building Department P.O. Box 1179 Town of Southold Southold, NY 11971 Subject: Roof-Mounted Solar Panels at the Otani Residence 1395 Henrys Ln Peconie NY. 11959 To Town of Southold: I have reviewed the solar energy system installation in the subject topic July 10th, 2023. The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department, Town of Southold, New York. The solar panel installation is in compliance with the requirements of the 2020 Residential Code of New York State, the 2017 National Electric Code, SEVASCE 07-16 "Minimum Design Loads for Buildings and Other Structures", NFPA Standard 70 and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. Markings in accordance with Section 690.53 of the National Electrical Code are provided. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property and public welfare. 3 Since ; OF NEriy James Deer 260 Deer Drive ��4 S.'.q -1 N'P Mattituck, NY 11952 p 631-774-7355 • - SS4tP i FIELD INSPECTION REPORT7 DATE COMMENTS ' FOUNDATION(1ST) O H -------------------------------------- FOUNDATION (2ND) ?b — z - o H ROUGH FRAMING& PLUMBING H V) (O r INSULATION PER N.Y. y STATE ENERGY CODE ilk- FINAL CGo I � ADDITIONAL COMMENTS S c 12 Oct --e l o; c 2 ZP f-CC7 3 o - c c e R SI r �- O 0 z H x e b H Zoho Sign Document ID:2A768FFA-OU52KIUZU_UAYNKWO53BH_RYFY8U6YSDMOINAFOKSAO �SUFFot��o TOWN OF SOUTHOLD —BUILDING DEPARTMENT �O Gyp y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtoMnny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only v IE II W/ I PERMIT NO. qllqb Building Inspector: MAR l 0 2023 UJ BUIWINb OEPT. Applications and forms must be filled out in their entirety. Incomplete TOWNOFSODTHOLD applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: Robert Otani SCTM#1000- 1000-074.00-01.00-010.000 Project Address: 1395 Henry's Lane, Peconic, NY 11959 Phone#: 201-913-5634 Email: Mailing Address: CONTACT PERSON: Name: Charles Jacabacci Mailing Address: 7470 Sound Ave., Mattituck, NY 11952 Phone#: 631-388-7041 Email: charles.jacabacci@e2sys.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Element Energy LLC Mailing Address: 7470 Sound Ave., Mattituck,NY 11952 Phone#: 631-779-7993 Email: permits@e2sys.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ✓Other 9.6kw $ 54,891.42 Will the lot be re-graded? ❑Yes ✓No Will excess fill be removed from premises? ❑Yes ✓ No 1 Zoho Sign Document ID:2A768FFA-OU52KIUZU_UAYNKWO53BH_RYFY806Y5DMUINAFOK5AO PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Residential Zone AC this property? ❑Yes ✓No IF YES, PROVIDE A COPY. I✓Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Charles Jacabacci ✓Authorized Agent ❑Owner Signature of Applicant: Date: Mar 152023 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Charles Jacabacci being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor/Agent (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this �O day of /�= I� ,_zo.2-3 _ Nota4dublic LOUIS J ROMEO Notary Public,State of New York No.o1R06314813 .PROPERTY OWNER AUTHORIZATION Qualified in Suffolk County Commission Expires November 17,202-6 (Where the applicant is not the owner) I� Robert Otani residing at 1395 Henry's Lane, Peconic,NY 11959 do hereby authorize Element Energy LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. 72� ot, u Mar 15 2023 Owner's Signature Date Robert Otani Print Owner's Name 2 Zoho Sign Document ID:2A768FFA-OU52KIUZU_UAYNKWO53BH_RYFY806YSDMUINAFUKSAO W. BUILDING DEPARTMENT- Electrical Inspector Off' �G TOWN OF SOUTHOLD v�.�- yr► Town Hall Annex - 54375 Main Road - PO Box 1179 ^ft IN Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roQerr. southoldtownny.aov_ sea ndCa�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Mar 15 2023 Company Name: Element Energy LLC Name: Jamie Minnick License No.: 52689-ME email: permits@e2sys.com Address: 7470 Sound Ave.,Mattituck,NY 11952 Phone No.: 631-861-5920 JOB SITE INFORMATION (Ali Information Required) Name:_ Robert Otani Address: 1395 Henry's Lane,Peconic,NY 11959 _ Cross Street: Phone No.: 2017913-5634 Bldg.Permit#: email: Tax_Map District: 1000 _Section: 074�.00 _. Block: 01.00_- Lot: of o.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) .9.6kw.roof mounted solar PV system consisting of 24 Enphase micro inverters model IQ8PLUS-72-2-US&24 QCELL solar_P_V . modules model Q.PEAK DUO BLK ML-G10+400 Circle All That Apply: Is job ready for inspection?: ✓ / NO Rough In Final Do you need a Temp Certificate?: `/ 4 NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: -- -A #Meters Old Meter# . New Service- Fire Reconnect- Flood Reconnect- Service Reconnected-Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT-DUE-WITH APPLICATION Request for Inspection Formals A�® CERTIFICATE OF LIABILITY INSURANCE DATE(MM7/2 2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERTS. FEDE INSURANCE AGENCY PHONE - FAX - - IC o A/C No): 23 GREEN STREET,SUITE 102 E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS. FEDE INSURANCE INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURERB: STATE INSURANCE FUND 523930 Element Energy LLC INSURERC: SHELTER POINT POINT 81434 ELEMENT ENERGY SYSTEMS INSURERD: GENERAL STAR MANAGEMENT CO. 7470 SOUND AVENUE INSURER E: MATTITUCK, NY 11952 INSURERF. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LTR NSD WVP POLICY NUMBER MM/DD/YYYY MMIDD/YYYY LIMITS COMMERCIAL GENERAL LIABILITY CL00275204 7/14/2022 7/14/2023 EACH OCCURRENCE $ 3,000,000 A X X DAMAGE TO RENTED CLAIMS-MADE � OCCUR PREMISES Ea occunence $ 100,000 #D IMA369203A MED EXP(Any one person) $ 5000 X Contractual Lia 7/14/2022 7/14/2023 PERSONAL&ADV INJURY $ 3000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 3,000,000 POLICY r PRO- JECT LOC PRODUCTS-COMP/OP AGG $ 3000000 OTHER: AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident F $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION 124494445 PER OTH- AND EMPLOYERS'LIABILITY Y/N 7/13/2022 7/13/2023 STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 B OFFICERIMEMBER EXCLUDED? 7 N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ 1,000000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ NY State DBL DBL567527 1/01/2022 1/01/2023 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 MAIN ROAD THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. SOUTHOLD, NY 11971 AUTHORIZED REPRESENTATIVE 203E12T S FEDE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD YOR Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured ELEMENT ENERGY LLC , 7470 SOUND AVE MATTITUCK,NY 11952 1 c.Federal Employer Identification Number of Insured Work Location of Insured (Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e., Wrap-Up Policy) 823336604 2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b. Policy Number of Entity Listed in Box"I a" SOUTHOLD, NY 11971 DBL567527 3c. Policy effective period 01/01/2022 to 12/31/2023 4. Policy provides the following benefits: ❑X A. Both disability and paid family leave benefits. B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/20/2022 By "a'At (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 4B,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) I I I 1111111111111111111111111111111°�°°°°111111111 NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE 0 t ^^^^" 823336604 ROBERT S FEDE INSURANCE AGENCYIle 23 GREEN ST STE 102 0 L I HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 95991 07/13/2022 TO 07/13/2023 7/19/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE SUR NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 126776733 ` Town of Southold a March 2nd, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Rdof.Maurited Solat Panels at the Otani Residence, 1395 Henrys Ln, Peconic N.Y* 11959 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3 second gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.7 pounds per square foot. Please contact me if you have any questions or comments about the above. in ly, �OF NE�,I, Q' S.DEAR .1"p James De rko E r 260 Deer Drive '' Mattituck, NY 11 2 631-774-7355 tONe' . --- X]R`Rails 8 XR10 Rail XR100 Rail XR1000 Rail Bonded Splices A low-profile mounting rail The ultimate residential A heavyweightmounbng All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. ^ G'apanningoapobi|ity ^ 8'apanningoapabi|ity ^ 12'apann|ngoopobi|ity ^ Self-drilling screws ^ Moderate load capability ^ Heavy load capability ^ Extreme load capability ^ Varying versions for rails ^ Clear and black finish ^ Clear and black finish ^ Clear anodized finish ^ Forms secure bonding -- Clamps & Grounding6D UFOs Stopper Sleeves Grounding Lugs MioroUnverter Kits ' . / ` � -AL Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount M|eorPOs to XR bond modules torails. into a bonded end clamp. equipment ground. Rails. ^ Fully assembled & |ubad ^ Bonds modules torails ^ Low profile ^ Bonds devices torails ^ Sing|e, universal size ^ Sized to match modules ^ Single tool installation ^ Kit comes assembled ^ Clear and black finish ^ Clear and black finish ^ Mounts in any direction ^ Listed toUL27O3 -- Attachments 8 FlashFoot2 Conduit Mount SlottedK,Feet Bonding Hardware Imam Flash and mount XRRails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XRRails with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. ^ Twist-on Cap eases install ^ Twist-on Cap eases install ^ Secure rail connections ^ T&Square Bolt options ^ Wind-driven rain tested ^ Wind-driven rain tested ^ Slot for vertical adjusting ^ Nut uses 7OG^socket ^ Mill and black finish ^ Secures 3/4'or1^conduit ^ Clear and black finish ^ Assembled and lubricated -- Resources Design Assistant NABCEP Certified Training Go from rough layout to fully Earn free continuing education credits, engineered system. For free. while learning more about our systems. Go to InonR/oge'cmmn/mem/gn ®fir IRONRIDGE Flush Mount System r Mt p �S Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty ® Entire system and components meet ® Twice the protection offered by newest effective UL 2703 standard. competitors. i 1 1 IQ8' and IQ8+ Microinverters INPUT DATA IDCIA: .1 , • Commonly used module pairings' w 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27'-37 - 29-45 Operating range v 25-48 25-58 Min/max start voltage ay 30/48 30/58 Max input DC voltage v 50 60 Max DC current'[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array,No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA IACI 108-60-2-US1 • Peak output power VA 245 300 - Max continuous output power VA 240 290 Nominal(L-L)voltage/range'. v 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over . 3 cycles Arms 2 Max units per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port baokfeed current- mA 30 . Power factor setting 1.0 Grid-tied power factor(adjustable) .0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency %" 97- 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -400C to+600C(-400F to+1400F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor 1 CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO:107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section" 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's_instructions. (1)No enforced DC/AC ratio.Seethe compatibility calculator at httpsJ/Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 1O8SP-DS-0002-01-EN-US-2022-03-17 f ENPHASE. ATJjKM. fix, 116 s IQ8 and IQ8+ Microinverters Easy toinstill Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- • Lightweight and.compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors - " power to AC power efficiently.The brain of the semiconductor-based microinverter . power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two=wire cabling _ = energy systems. High productivity and reliability -- • Produce power even when the • - grid is down* More than one million cumulative hours of.testing Ifyear firrifted _ tWarramyClass 11 double-insulated Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reabltty enClOSUre. Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative • Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- pOWered PV mOdUIBS and analysis software. leading Conned warranty of up to 25 years. Microgrid-forming •• Complies with the latest advanced grid;support** CERTIFIED • Remote automatic updates for SAFETY -the latest grid requirements Connect PV modules quickly and easily to IQ8 Series I08 Series Microinverters are UL Listed as • Configurable to support a wide. Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. • Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other •Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. '•I08 and IQBPlus supports split phase,240V I08SP-DS-0002-01-EN-US-2022-03-17 installations only. MECHANICAL SPECIFICATION Format 74.0in x 41.1in x 1.26 in(including frame) (1879mm x 1045mm x 32mm) 74A•(1879m) 16.6(396.6mm) 42.W(1066mm) Weight 48.51bs(22.Okg) Front Cover 0.13 in(3.2mm)thermally pre-stressed glass with t49.2•(1260mm) anti-reflection technology 4.G-&gF.n..M1W(4 -) Back Cover Composite film 39.T(ON-) Frame Black anodized aluminum ® 4u'Uo4smm) Cell 6 x 22 monocrystalline O.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes Leb�� x49T(1360mm) Cable 4mm2 Solar cable;(+)>_49.2in(1250mm),(-)>_49.2in(1250mm) 1 4.Mwmin99ob(DETAIL{� - Connector SMubli MC4;IP68 DETAILA 0.63'(lamm) T 0.9V(24.6mm)I-Q�0.33•(a.6mm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-0 W) Power at MPP' PMPP [W] 385 390 395 400 405 E Short Circuit Current' I6c [A] 11.04 11.07 11.10 11.14 11.17 E Open Circuit Voltage' Voc IV] 45.19 45.23 45.27 45.30 45.34 .5 Current at MPP IMPP [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VMPP IV] 36.36 36.62 36.88 37.13 37.39 Efficiency' q [%] >_19.6 >-19.9 >_20.1 >_20.4 >>>20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' Power at MPP PMPP [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current ScI [A] 8.90 8.92 8.95 8.97 9.00 0 E Open Circuit Voltage Voc IV] 42.62 42.65 42.69 42.72 42.76 •c 5 Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP IV] 34.59 34.81 35.03 35.25 35.46 Weasurement tolerances P_±3%;I6c;Vcc±5%at STC:l000W/m',25±2°C,AM 1.5 according to IEC 60904-3•'80OW/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98%of nominal power during ao F M mY° first year.Thereafter max.0.5% z I I I I ______________________________ degradation per year.At least 93.5% two __L_____I_______ I b a of nominal power up to 10 years.At LL z least 86%of nominal power up to u 1"- > Q ,6 _______---------- _____________ - s6 5c 25years. � --r-----I------�-----ti------, z �z 5 I I I 6. All data within measurement toleranc- ; m � es.Full warranties in accordance with mD aoo 6ao soo loco ai a the warranty terms of the Q CELLS am sales organisation of your respective NRADIANCE[W/rtJ] o m „ country. saasam�ae� b6p lowm,P p. YEARS Typical module performance under low irradiance conditions in o w°°Ne°8"0atlotl� P°vb 0A(m�S p1°e 0( comparison to STC conditions(25°C,1000 W/mz) Lo m m TEMPERATURE COEFFICIENTS o Temperature Coefficient of I6c a [%/K] +0.04 Temperature Coefficient of Voc [f [%/K] -0.27 Temperature Coefficient of PMPP y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) m 0 D PROPERTIES FOR SYSTEM DESIGN a w Maximum System Voltage V6V6 IV] 1000(IEC)/1000(UL) PV module classification Class II o 0] Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 d Max.Design Load,Push/Pull' [IbS/ft'] 75(3600 Pa)/55(2660 Pa) Permitted Module Temperature -40°Fupto+185°F o Max.Test Load,Push/Pull' [IbS/ftz] 113(540OPa)/84(4000Pa) on Continuous Duty (-40°Cupto+85°C) m m 'See Installation Manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m Q 0 ULalityC CE-compl-T Ib a3 n Quality Controlled C 1730 Rheinland, �® �e 1� �d� 0�-0-1 I4o'HCI N IEC 61215:2018,IEC 61730:2016, m U.S.Patent No.9,893,215(solar cells), TOVMtlnlsq Horizontal 76.4in 43.3in 48.Oin 1656lbs 24 24 32 0 QCPV Certification ongoing. C US packaging 1940mm 1100mm 1220 mm 751kg pallets pallets modules c_m°a UL 617W www.tw.mm m ID nnmm� a ur Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwhe 0:CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618.USA I TEL+1 949 748 59 96I EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us i - I I !� powetled by • � � YR Q `'. TOP BRAND PV- •o 'y - euaove ./ Warranty 'ate ®CELLS Aoduct&Pertarrartce Yield Security BREAKING THE 20%EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of v� the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY C?; Optimal yields,whatever the weather with excellent low-light and temperature behavior. "-_ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QTM. EXTREME WEATHER RATING (� High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). '�2 A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year 1 linear performance warranty2. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500 V,96 h) 'See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany OCELLS SCOPE OF WORK DESIGN t DRAFT'NG 5Y: • l ELEMENT ENERGY LLC TO INSTALL A 9.6 KW 50LAR PHOTOVOLTAIC(PV)SYSTEM AT THE OTANI RE5IDENCE, REVIEW 3Y J W. .NABCEP CERTIFlE-_ LOCATED AT 1395 HENRYS LN, PECONIC, NY 11958. 0511 .2-129 THE POWER GENERATED BY THE PV 5Y5TEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL 5ERVICE EQUIPMENT KEV15101145 IM�N - X5c;RIPfID4 DAR 5Y5TEM RATING 0R1G'NAL 03�_ 9.6 kW DC STC -- EQUIPMENT SUMMARY APP ��EpD AS DATE: J.V B.P.# 24 QCELL Q.PEAK DUO BLK ML-G 10+400 WATT PV MODULES 24 ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS FEE: BY: cud,oe CONTRACTOR t IRONRIDGE XR100 MOUNTING SYSTEM NOTIFY BUILDING DEPARTMENT AT SHEET INDEX 765-1802 8 AM TO 4 PM FOR THE e * �"„ ELEMENT ENERGY, LLC. PV-I COVER FOLLOWING INSPECTIONS: PROJECT LOCATION 7410 SOUND AVE PV-2 51TE PLAN 1. FOUNDATION - TVJ0 REQUIRED PV-3 ROOF PV LAYOUT FOR POURED CONCP�TE LICENSE # 6 MATTITUCK, N 5 Y 1 1 19 I 5 PV-4 5TRUCTURAIJ DETAILS E 5ECTION5 LICENSE # 52689-ME PV-5 3-UNE ELECTRICAL DIAGRAM 2. ROUGH - FRAMING & PLUMBING _ PV-6 LABELS 3. INSULATION N GOVERNING CODES 4. FINAL - CONSTRUCTION MUST o° BE COMPLETE FOR C.O. 2017 NATIONAL ELECTRICAL CODE. ALL CONSTRUCT;ON SHALL MEET THE 2020 RESIDENTIAL CODE of New sTarE. 2020 FIRE CODE OF NEW YORK STATE.ATE. REQUIREMENTS OF THE CODES OF NEW PROJE�T NANAF W 27o°O �-90°E �A5CE 7-16 AND NFPA-70. YORK STATE. NOT RESPONSIBLE FOR .*:, UNDERWRITERS LABORATORIES(UQ 5TANDARD5 DESIGN OR CONSTRUCTION ERRORS. 240° V 120° ••OSHA 29 CFR 19I0.269 210' 150° I�'" W CO GENERAL NOTES 180 W z CO 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT S lLJ THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK y AGREE THE SAME. AERIAL VIEW W z Z 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED _ _ _ APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWM�(� TP�OVAL STAMP = U aA INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTORS LIABILITY, WORKMAN'S COMPENSATION, - �JVNI�L7 VVHLrZI�J' z Z AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES NEW YORK STATE & TOWN CODES 0� OU ALL RULE5 AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO JURISDICTION. COMMENCING WITH WORK. AS REQUIRED AND CONDITIONS OF 0 m LL-1 _ 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ni l WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB 51TE DURING THE Ov ('aEy, THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS )- ENGINEER. SHOULD HE FAIL TO FOLLOW TH15 PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND "' �i r 60. co ARD HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT HE SHALL A55UME ALL CONTINUE WITH THE WORK RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, - r f �,• 5"EE7 NAVE 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY -**� o's SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT m + LATEST A.I.5.0 FABRICATED AND INSTALLED AS PER Z SPECIFICATIONS. CONSTRUCTION. IN BOARD OF FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE �� 0?2 COVER G. ALL ELECTRICAL WORK SHALL DRAWINGS, WHERE DIMENSIONS ARE E5TA5U5HED BY EXISTING �0 �, UNDERWRITERS APPROVED AND N ACCORDANCE WITH N.E.C. OACONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING OCCUPANCY OR �O Sslo NYS CODES �REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. USE IS UNLAWFUL CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEERS DRAWNG SCALE 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS CERTIFICATION OF THESE PLANS. WORK FROM THE 517E AND DISPOSE OF IN A LEGAL MANNER ON WITHOUT CERTIFICAT 8. THESEAJHEDRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND A WEEKLY BA515 OR SOONER IF CONDITIONS WARRANT. ELECTRICAL N .T.5" . SHALL T FOR THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK. THE SITE TO BE CLEARED INSPECTION REQUIRED PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS.THE FACILITY 15 TO BE OF OCCUPANCY THEY ARE NOT T IS USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE EXTENSIONS TO THIS PROJECT SHEET NJMBER TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL � � PV- EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. RESULT OF HIS WORK. ------ TAX MAP: 1000-074.00-01 .00-010.000 LEGEND DESIGN i DRARIr;G 8Y ELEMENT ENER.," LLC E7OSTNMG UTIJTY METER MAIN SERVILE PANEL REVIEW BY J M NABC P ERT!`IF� NEW PV SUB-PANELS 05 1. :2-1 29 ABC DISCONNECTCOMBINER N ATE �� KEV1510N5 CND ELECTRODE �PV MODIIE � 7ESCRIT'iON �4*:( vnOo� 04t!u1NAl 03-Oi-2023 —RACKING RAIL o ATTACNMENf POINT `^' ---RAF1CH ,6'x 30 GROUND ACCE55 TYP V Y Z�oa 0 1200 150' _ -*—ROOF PITCH ANGLE esuwRLAv MEhR i cJ OPLUMBING VENT l ®SK LX*+T � / j� CONTRACTO< ®a+uM+Er /° f COMPOSTE SHRIGLESGOOD CONDITION 1/ POTENTIAL ISSUES �� r ELEMENT ENERGY, LLC. TRIM/REMOVE AS NECESSARY; '� r 7470 SOUND AVE MATTITUCK, NY 1 195 LICENSE # 74 I-HI LICENSE # 52G89-ME PROJECT NAME LLJ C) CL/ wU = z �/� ~ mLU-i f� 33-92 C �Epp1- -NOTE O 5,IEET NAME 1 .)THE ROOF 5ET5ACK/PATHWAY SHALL NOT BE fr� REQUIRED TO ROOFS WHEN OPPOSING OR SITE PLAN !� - ' ( � o•', '''O�x T� ADJACENT ROOF 15 ACCESS ROOF IN - ACCORDANCE WITH R324.G.I EXCEPTION OF Z s 2020 NY5 RESIDENTIAL CODE. F+- :� 5 0 C9 DWWWCSCALE CONSTRUCTION NOTES L 13'-2" SrEET Nl:MSEF 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE PV-2 MANUFACTURER'5 INSTALLATION INSTRUCTIONS. 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. TAX MAP: 1 000-074.00-0 1 .00-0 10.000 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. CONSTRUCTION SUMMARY (24)QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULE5 DE51GN 4 DRAPING BY E:EMENT ENERGY LL1 (DIMENSIONS: 74'X 4 1.I'X I .3") REVIEW BY J.M NAB:EP CER"ITIE- (24) ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS N 051 12-12? (44)ATTACHMENT POINTS @ G4'O.C. MAX. p° (193.8) LF IRONRIDGE XK 100 MOUNTING SYSTEM. 1 ROOF TYPE: ASPHALT SHINGLE(51NGLE LAYER) REV1510N5x-5„;U-noN i DAE ev CONSTRUCTION NOTE5 c7gp°E MrA1 AL 03-0I-2023 1.) ALL EQUIPMENT 5HALL BE IN5TALLED IN ACCORDANCE W 27p°� 120° WITH THE MANUFACTURER'S IN5TALLATION IN5TRUCTION5. 6 .36'GROUND ACCESS TYP ° Q ° 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 24p Asp MINIMUM NEMA 3R RATING. 2►p Agp° 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE S FIELD VERIFICATION. 'NOTE I.)THE ROOF SETBACK/PATHWAY SHALL NOT BE �• / � l' REQUIRED TO ROOF5 WHEN OPP05ING OR / ADJACENT ROOF 15 ACCF-55 ROOF IN ccN RACTCR ACCORDANCE WITH R324.G.I EXCEPTION OF 2020 NY5 KE5IDENTIAL CODE. ELEMENT ENERGY, LLC. 7470 SOUND AVE .� MATTITUCK, NY 1 1952 LICENSE # 74 I- � G G HI LICENSE # 52G89-ME �c�+a „• PROJECT NAME r— f zco Ln ARRAY#I 93" LLJ to — 1 ((�� ;r �, 2 14'AZ MUT1 W z 14 �' [L/ = v f % z,n z . .. OmO LLJ LEGEND ®c EXISTING;UTILITY METER �� MAIN SERVICE PANEL NEW PV SUB—PANELS A Y#2/ A/C DISCONNECT 14 ODULE5 r COMBINER 26'°ITCn INVERTERS ', ,� 24•AZIM..�r i N�Iw- SMEE"NAME & GND ELECTRODE ,Y B MODULE RA ROOF DETAI RACKING RAIL � /. �A ,�, U O ATTACHMENT POINTLu c' �•l ---RAFTERS \ PROOF PITCH ANGLE f•. %///%///i%/l/%////i: �'• .�" (j DRAWING BCALE ®j SUNRUN METER �.... <• T ?`� o �/� ®VENT `— ,rQ' C.S�J'IJv I /6" — I 1-011 0 PLUMBING® VENT SKY IJGNT ®CHIMNEY 45f1EET NUMBER ®COMPOSITE GOOD CONDITION �� —TRIMt`EM sr1A IssuEs TAX MAP: 1000-074.00-0 I .00-0 10.000 PV-3 POTENTIAL ASS NECESSARY oAD CALCJ_aT DP, J.P � = ARRAY X2 ITEM DESCRIPTION A�,RAYS #i-2 Dcs'G t DEAF-'. RD Kic;16ie Bearrl/BOard G` 2' X 2' D. FIR F - Et�M_Y F YER'_='. _ MODULE WEIGHT(Lb,,) 464 48.4 R Roof Rafters 2"X i a'D. FIR I G"O.0 REVIEW BY,1.M YAGWEPCrIM"IFl- (D) Deckin 5/8" PLYWOOD 051 12 29 a of MODULES f o P Pitch 2GQ #334 -OTAL MODULE WEIGHT abs) 4840 G77 6 J Cellln o,st 2"X "D. FIR 8 I " .C. REV151ON5 ' Knee waifs 2"X 4"D FIR lad 1 MTOTAL I_E14Gft1 OF RAIL(Ft) 69 3 24.5 f 1 Horizontal 5 an of R) 13 i" MAX. RAIL WEIGHT PER FOOT(Lb5) 0498 O 68 TOTAL PAIL WEIGHT fibs) 47.f 84.7 (RB M OF 5TRAfI00FF5 6 28 (R) WEIGHT PER STRANDOFF jibs) 2 2 (D) TOTAL 5TA1`-lDOFF WEIGHT(Lb,,) 32 5G TOTAL ARRAY WEIGHT fLbs) 5G3., 8 f 8.3 POINT LOAD(Lb,) 35-2 29)2 `OTAL ARRAY AREA_15q Ft) 214 1 299 7 A,Z,ZAY DEAD LOAD;Lis/Sa Ft) 2.6 2 7 ELEMENT ENERGY, LLC, WIND DESIGN SUBJECTTO DAMAGE FROM 7470 SOUND AVE GROUND SEMIC VANTER ICE BARRIER AIR MEAN Special FT000 MATTITUCK, NY 1 1 95 SNOW � T.1 > � DFSlfii Hest DESIGN UNDERi.AYMENT FRMZAIG ANNUAL = -� �K) WAD' (MOO e� �a +� CATEGORtrr me T�� TEIW WIQUWEd' 1A?JNtD� INDW TEND , LICENSE # G74G I-HI `60d zone" dew %� ) LICENSE # 52G89-ME 20 140 NO NO NO B SEVERE ;FT HEAVY 15"= YES 599 51'F } MANUAL)DESIGN CRITERIA' i IKiater suav w AhitWe Yroer D-4p Heading - Elevatwr Latitude des�I fteiatiird asaBRL cot►ectfew famar tespvatue cocum temperatiffe o mwerat— 108 FT 41"N 15"F 86"F 1.00 79"F 75'F 55'F Cooling VAnd Rand Caiaiaden Daft IFfnller Saalroer (J) temperature difference o W wet hob raw fumawky humidity LU headn z Ln 11-F 15 MPH 7.5 MPH 72"F MEDIUM(M) 40% 32 GR @5D%RH z Q For SI:1 pound per square foot=0 0479 kPa,1 mile per hour=0 447 m/s ROOF FRAMING DETAIL 11 J a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength required for weathering shall govern The weathering column shall be filled in with the weathering'index,"negligible.""moderate'or"severe"for concrete as determined from Figure R301.2(4) The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652 lL,W W z z b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govem.The jurisdiction Shall fill in the frost line depth column with the minimum depth of footing below finish grade. MODULE MOUNTING CLAMP _ = U C. The jurisdiction stall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A] Wind exposure category shall be determined z z on a site-specific basis in accordance with Section R301 2.1 4. SCIAR MODULE Q Ln Q e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York (— (J) (Jm State.Deviations from the Appendix temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official [Also P_%LT AI ID rau? l 5TAWLE '- O see Figure R301 2(1)] _ [LJ f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301 2 2 1 / Q_ g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New + York(NYCRR)shall adopt a flood hazard map and supporting data The flood hazard map shall include,at a minimum,special flood hazard areas as identified b the Q y.t Federal Emergency Management A m the Flood Insurance St for the community, y tIPJCGf ALUMINUM Rn rigs cY ge Agency' Study rty,as amended or revised with: i The accompanying Flood Insurance Rate Map(FIRM), ALUMINUM`L' 6F.ACK.= ii.Flood Boundary and Floodway Map(FBFM),and iii Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section UMINUM FLA511ING C h. In accordance with Sections R905.1 2,R905 4 3 1.R905.5.3 1,R905.6.3.1,R905.7 3.1 and R905.8 3 1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall fill in this part of the table with"NO" �F N E W L The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403 3(2)or from the 100-year(99 percent) ���� DE fio y�� T RU CTU RA value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32"F)" A5F,?ALT Sr1If I--LP pC rt Q SOS J. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method 5/1 6'x 6"5TAINL r (Base 32'F)." 5TEEL LAG EOLT 1N Q A f It. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 2 12`MIN THPT, r } .r, ' a urisdiction shall fill in this part of the table with'YES"Otherwise,the jurisdiction shall indicate"NO"in this PENL`TkATl0+1=F t"- 1 Pa 1 part of the table "° W I. In accordance with Figure R301 2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL s if LL "YES"and identify an specific requirements Otherwise,the jurisdiction shall indicate"NO"in this (EQUIVALENT CK Fs:. y specpart of the tables? AS NOTED m. In accordance with Section R301 2.1 2 the jurisdiction shall indicate the wind-home debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the � � 5p2 table n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the �SS�ON jurisdiction o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301 2(6)for sites at elevations up to 1,000 feet Sites at F[CORRUGATED STPEL ROOF]elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet [ IAT ROOF] (') See Figure R301 2(4)B PV-4 TAX MAP: 1000-074.00-0 I .00-0 10.000 MOUNTING DETAIL EREVEW5Y :DRA"FTING BY: RGY:IG SOLAR ARRAY ON MAIN HOUSE 9 6 kW BCEP(24)QCELL Q PEAK DUO BLK ML-G 10+ 400 WATT PV MODULES -i 29 (2)5TRING5 OF(12)MICRO-INVERTERS '(2)STRINGS TOTAL REVISIONS r „ TO UTILITY GRID J'5;RJPTI0N :)All- Rfv STRING #I oR1:1NA! o3rl_z0z3 - ---------------- -_�^ - �-' -- --- -- --s` 1 N BI DIRE TIONAL -�' - II ^ - UTAJTY METER 1- ---------------�- _ —Q-—�— CJ �J`�j� PHASE.240 V , 1 N 5TRING #2 _ - - MrRo wv_RT=_R 24C V 200A ELEMENT ENERGY, LLC. BRAN`" CA9LE TrPI; ENP-IASf-09P.U5-72-2-L,5 7470 50UND AVE C1R"—lift AL i °`vim" ' L1 " z- n-BRWfa MATTITUCK, NY 1 1 97_- �CF�w=I5 OFF z`D °DA N_M.A Lk_S UCEN5E # G74G I -r S. TDED: 1 1 �•9`_abrA�_,: ✓'1^4 f.'-OM51NER 4 TwicA_ .'�R vA++:s vim»�:,E-r LICEN5E # 52G89-ME 1�L S [ 1 1 1 , - -- ' 111 r 1 = PROJECT NAME MAIN SERVICE PANEL ,$a i i-rn 3-a 24J VAC N lLJ �O I c - ILJ Z L() U Q 0> I I z j - ( E LLJ LLECTFODE SYSTEM u Q (n LLJ Z L-------- ' CL/ Lu WIRE CONDUIT 5CIIEDULE — _ _ Q CIRCUIT CIRCUIT CIRCUIT AMBIENT CONDUCTOR CONDUCTORS MAX CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT L ) Z AMBIENT TEMP ESTIMATED Voltage Drop(%I.D # ORIGIN DESTINATION 51ZE PER POLE QUANTITY DERATE INSULATION 51ZE OUANTIY O T INSULATION (CU/AU TYPE SIZE TEMP DERATE DISTANCE O m U 3 i 0 155"31 310.5;5)!2aK3c) I INVERTERS COMBf14ER PANEL AWG#1 2 1 4 O 8 USE-2/PV Wire AWG#8 I BARE CU FREE AIR 1" 559C 0.84 80 FT 2.0% LU OR EMT 2 COMBINER PANEL MAIN PANEL AWG#8 ) 3 I THWN-2 AWG#8 THWN-2 CU PVC I' 45QC 0.95 r 25 FT 0.5% ELECTRICAL NOTES pF NFW CALCULATIONS FOR CURRENT CARRYING CONDUCTORS �,�P �DE�cR/i }'0� SnEE'NAME 1.)ALL EQUIPMENT TO BE USTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #! PV Source Circuit Wire Am aat 2J ALL CONDUCTORS 5`1ALL BE COPPER. RATED FOR GOO V AND 909C WET ENVIRONMENT P y Calculation CONFIGURATION i O� 3.)WIRING,CONDUIT,AND(RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY (NEC 690.6(B)(I)]: (Isc)'(#of stnngs)'(I.5G) = 18.15 A Modules per String 2 * 'Z p * 3—LINE D I A. r- ..r. TO,AIJD LOCATED AS CLOSE AS POSSIBI�TO THE 1JEARE5T RIDGE,HIP,OR VALLEY. AWG#12. ampacity'Temp Derate = 20.16 A �y 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 20 16 A> 18 15 A,therefore DC wire size is valid. Modules per Inverter 1 M COMPLY WITH NEC 1 I0.2G. #2 Inverter Output Wire Ampaclty Calculation Number of Inverters 24 Z Inverter Max Amperage output' (1 25) = 36.3 A N 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS CONTRACTOR SHALL Record low tem _I OQC FURNI5H ALL NECE55ARY OUTLETS, SUPPORTS,FITTINGS AND ACE55ORIE5 TO FULFILL AWG M.ampaaty'(Temp Derate)'(Condult Fill Derate) = 52.25 A Voc Temp Coefficient 0 24%/QC :0? 5`u' DRAwivG 5'ALf APPLICABLE CODES AND STANDARDS. 52.25 A> 3G-3 A. therefore AC wire size is valid. G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, DC SYSTEM SPECIFICATIONS SS14aP THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY Operatticl Current 10.8 A I T 7,)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. O eratln Volta c 37.1 V ' `� 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULP FRAME AND MODULE Max. System Voltacjc 49.G V SUPPORT RAIL, PER THE GROUNDING CUP MANUFACTURER5 INSTRUCTION- Short Circuit Current 13,9 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOU5 COPPER G.E C.VIA WEEK LUG OR ILSCO GBL-4DBT LAY-IN LUG. AC 5Y5TEM SPECIFICATIONS SHEET NUMBER 1 O)THE POLARITY OF THE GROUNDED CONDUCTORS 15(postivetnevtive) Max AC Output Current 36.3 A PV-5 OR 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. Operating Al-Volta 240 V TAX MAP: 1000-074.00-0 1 ,00-010,000 SERVICE METER OI O DESI.'a\t DRAF?'N i BY: -- I N5TALLATI O N NOTE .'LEMENr ENERGY LLc SOLAR PV SYSTEM PHOTOVOLTNC • • e e • ( 1 ) ALL LABEL 5HALL BE INSTALLED IN REVIEW 305 I1N 25C 129CERTIF't ® © EQUIPPED WITH I SOLAR BRE� ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN REQUIREMENTS. IEV151ON5 -.__- (2) ALL LOCATIONS ARE APPROXIMATE AND o�1,A_ 03A 2023 REV SOLAR AC LOAD CENTER - OUTSIDE I DO WT RELOCATE TM REQUIRE FIELD VERIFICATION. r~ OVB�1�T OEVIC>t ° . (3) LABELS, WARNING(5) AND MARKING O nm PAM StRO w To Og ® SHALL BE IN ACCORDANCE WITH NEC Wor Po9noNTO sw wm I PVMMU MORMUC 110.2 I (B). 9'D°"'"7JAD""f"M' AC DISCONNECT CAUTION (4) THE MATERIAL USED FOR MARKING - -- - °'�"E"•`°U,�°"�'°"" MUST BE WEATHER KE515TANT, IN SOLAR AC LOAD CENTER- INSIDE 20 ® � _".�= COMPLIANCE WITH NEC 110.2 I (B)(3).n.�.._ aL (5) THE PV SYSTEM CIRCUIT CONDUCTORS THSEOUFNEiTFID6YIRILTIKE 7DUALR SUPPLY SHALL BE LABELED INSTALLED IN ELEMENT ENERGY, LLCVE , �„� ITYGRID � COMPLIANCE WITH NEC G90.3 1 . MATTTOUCKO NY 1UND A95 W W SWPLY OUBtCURRBYI OLAR — DEVIcFE 91AU11MEILIXfD ELECTRIC SYSTEM LICENSE # G74G 1-111 CONDUIT - INSIDE BUILDING A!F"I CWWSIA? LICENSE # 52G89-ME O � _ THIS SERVICE METER ELECTRIC SHOCK HAZARD 1!mw4mp= OVOLTAICEM ���SERVED�A PROJE^NAYS TERMI WS ON TIE LIE AND PHOTOVOLTAIC SYSTEM LOAD SIDES MAY BE EIIIIERGIZED DO NOT ADD LOADS j CONDUIT - OUTSIDE BUILDING —"I" OPENPOS "i0N ® ® W Z Ln ® RN1NG -_ _ w DUAL PONIER SUPPLY) Q ELECTRIC SYSTEM L.0 Z MAIN SERVICE PANEL - OUTSIDE ACALITION SOLAR CIRCUfT 0/ = U OCAUT►oN o SOLAR BECTFOC SYSTEM C7N� O m W © . . . t • MAIN SERVICE PANEL - INSIDE POWER SOURCE I OUTPUT CONNECTION DO NOT RELOCATE THIS ® 7 RE � sneer vANE OVERCURRENT DEVICE OF fJE y `. DEC LA13EL5 AC DISCONNECT/BREAKER E N 2 DRAWING SCALE 0 0 0 ® ® SSIot, - N .T.S. 5'1EET NUMBER PV-G TAX MAP: 1000-074,00-0 1 .00-010.000