Loading...
HomeMy WebLinkAbout49841-Z �o�OSUFF t c y. Town of Southold 11/4/2023 a P.O.Box 1179 0 C* 53095 Main Rd oy o� J Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44719 Date: 11/4/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1100 Theresa Dr,Mattituck SCTM#: 473889 Sec/Block/Lot: 115.-13-15 Subdivision: - Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/19/2023 pursuant to which Building Permit No. 49841 dated 10/5/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Byrne,Tami&Kevin of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49841 10/25/2023 PLUMBERS CERTIFICATION DATED y pki/x Aut oriz d ignature �o�SUFF coo TOWN OF SOUTHOLD ay BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • � fi SOUTHOLD, NY �o�ya°a�s BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49841 Date: 10/5/2023 Permission is hereby granted to: Byrne, Tami 111 Millet St Dix Hills, NY 11976 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. At premises located at: 1100 Theresa Dr, Mattituck SCTM # 473889 Sec/Block/Lot# 115.43-15 Pursuant to application dated 9/19/2023 and approved by the Building Inspector. To expire on 4/5/2025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector pF SO!/ry�l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.deviinl-town.southold.nv.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Tami Byrne Address: 1100Theresa Dr city:Mattituck st: NY zip: 11952 Building Permit#: 49841 Section: 115 Block: 13 Lot: 15 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 12.555kW Roof Mounted PV Solar Energy System w/ (31) QceIIQpeak 405W Module Combiner Panel w/220x3 215x1, AC Disconnect Notes: Solar Inspector Signature: Date: October 25, 2023 S. Devlin-Cert Electrical Compliance Form f # TOWN OF SOUTHOLD BUILDING DEPT. couto, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: /uu DATE INSPECTOR 44mla ` �aOE SOUIyp / I f `� a-elf A # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR dol ,' #a0FS0UTyO# TOWN OF SOUTHOLD BUILDING DEPT. 0 cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ eFINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Gd 7z- 6.6- p DATE 0-30 -23 INSPECTOR J Town of Southold 1 gbCto9eMh, 2 Building Department Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Subject: Roof Mounted Solar Panels at the Byrne Residence, 1100 Theresa Dr, Matittuck, NY 11952 To Town of Southold: I have reviewed the solar energy system installation in the subject topic October 27th, 2023. The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department, Town of Southold, New York. The solar panel installation is in compliance with the requirements of the 2020 Residential Code of New York State, the 2017 National Electric Code, SEI/ASCE 07-16 "Minimum Design Loads for Buildings and Other Structures", NFPA Standard 70 and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. Markings in accordance with Section 690.53 of-the National Electrical Code are provided. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property and public welfare. Sincer yr James Dee osk, PE ��OF NEtI,Y 260 Deer Drive :�J DEER O Mattituck, NY 11952 ��' �o 631-774-7355 t W Z 07z OFsS IONP LELD INSPECTION REPORT DATE COMMENTS ' ro t� FOUNDATION (1ST) "C H ------------------------------------ FOUNDATION ----------------------------------FOUNDATION (2ND) 7. _ O 0 O` c H ROUGH FRAMING& PLUMBING r W r r� INSULATION PER N.Y. '•j STATE ENERGY CODE 0• .2 Ok-- 2 C'.D• kndr FINAL ADDITIONAL COMMENTS O b � H z x d b H O�g�fFOlK�oG TOWN OF SOUTHOLD-BUILDING DEPARTMENT a y2 y i Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowm.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D PERMIT NO. Building Inspector: S E P 1 9 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner;an, BUILDING DEPT. Owner's Authorization form(Page 2)shall be completed: TO`A-N Date: 11 . OWNER(S)-OF PROPERTY: Name: ke,vISCTM#1000- 11S . 00 — t� ©O . 0 ��.y 0U Project Address: Y100 NA It 0�s � Phone#: 6 b 1 _-7-� 9 9 93 Email: Mailing Address: 11 0o —1�'1P.1'• S M��1 . CONTACT PERSON: Name: �C 3rf�(/L Aix, P � Mailing Address: 7 -7o �So v, 1 j q—z;d— Phone#: lei Email: qJ DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: e,Me-yl.`�- ,r(;--(�� Mailing Address: `7�1�C} LZnC)L fat,Vr, 1T)e4 -)q-U0j' IVV. 1161 — Phone#: tU 1,, � ? G , '� (r1 Email: � rn)4S 5 . Coro DESCRIPTION'OF PROPOSED CONSTRUCTION EJ New Structure DAdditiorX ❑Alteration ❑Repair El Demolition Estimated Cost of Project Other �,SO V ('sLlf'�4ckll $ 3 5 O a9 • `, Will the lot be re-graded? ❑Yes-No Will excess fill be removed from premises? ❑Yes ,Vo 1 (gash Ro,), k rn c; e.c y" P L✓ ISS y 13.161561C 110 // PROPERTY INFORMATION Existing use of property: Intended use of property: ,Q Zone or use district premises is situated: Are there any covenants and restrictions with respect to s this property? ❑YeS No IF YES, PROVIDE A COPY. heck Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): _Lo►rrG��Y1-e> i -C�1'l7>� Authorized Agent El Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF 13--t Io Y- (-w i,r 1 Pc/,l being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the CQY-7)-Yr6t(r-Oy— (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this i n LS day of 20 NotaDf Pu I' DEBRA A SEPULVEDA Nay PVgW,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATI N Rgon 06"SE6012691 Q,>g"InSu8' (Where the applicant is not the owne )Blom I, Key► �I �n� residing at 1 h����� �f .)-`n C.le JI ado hereby authorize F-I-r—rne.n4- e rY-c ff v1 L_. —C- to apply on my behalf to h own uthoId Building Department for approval as described herein. 00, 111023 O. er's Signat Date \j Ian 13 rV)� Print Owner's h4,me 2 �oSUFFall �o BUILDING; DEPARTMENT- Electrical Inspector Gym TOWN OF SoUTHC➢I_D y z Town Hall Annex - 54375 Main Road - PO Sox 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrO-southoldtownny.Qov- sea nd(cDsoutholdtownny aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: q t Company Name: E 1e--rncn -- ng-;��wL Lc Electrician's Name: a-y� License No.: 9-M C' Elec. email: 4S ,, � � �s ,C-oro Elec. Phone No: `'7-7,9 7,q 13 [Z I request an email copy of Certificate of Compliance Elec. Address.: 7, L-1 '10 dowi lL avt' M&4-'y1aI - JOS SITE INFORMATION (All Information Required) Name: ( .cl 9 L1 r nt-., Address: I l coo —they-C.5 #,– 't�v% Cross Street: "R-Conk- Phone PCon; -Phone No.: 7 '7 q- 1 l-3 SIdg.Permit#: L,1 q91-1email: S(z, &- a � Tax Map District: 1000 1 Section: [IS .o o Block: 13. -0,0 Lot: 0 l S. o►o BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES NO ❑Rough In ❑ Final Do you need a Temp Certificate?: F-1YES '�4-1 NO Issued On Temp Information: (All information required) Service Size❑1 Ph03 Ph Size: A #Meters Old Meter# ❑New Service[:]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals n 1 n2 n H Frame n Pole Work done on Service? F1 Y FIN Additional Information: roof. �-,���►��d�, �o��� PV -S JS4ero 3 I M 0 d VL I Fs -. C¢ c e.1 l - C;2 -Pe eLl<� Z)LCO 8)< C 3 ) i n ve✓-)1�ck-s -e-n kcL.st") -- IQ P I L't -7z:p- ro y-, 12,cl js c,P-e"t PAYMENT DUE WITH APPLICATION rn od',--I BUILDING DEPARTMENT- Electrical Inspector ® > TOWN OF SOUTHOLD Nz zTown Hall Annex - 54375 Main Road - PO Box 1179 ^+ :t Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCaisoutholdtownny.gov- seandc@-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Au Information Required) Date: 1z, Company Name: 1,c_rnc 4-- Electrician's Name.-ZJ_ License No.: 49 M C Elec. email: s , Elec. Phone No: T� 1 y q 1.3 [Z I request an email copy of Certificate of Compliance Elec. Address.I 1L.1 7 0 6vtcf1 et- Ak, fy1&44 JOB SITE INFORMATION (All Information Required) Name: KC t n Y'n Address: I 1 ot) l hty-'CS V Cross Street: : Pcc n c_ 61vd, Phone No.: '/ r7 ,_ 10 `3 Bldg.Permit#: L email: eo Tax Map District: 1000 Section: I t S .c o Block: 13 . Lot: o 15, opo BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly)-', Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YESNO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals M 1 2 H Frame Pole Work done on Service? Y N Additional Information: (t A_s �-e roc,(- - ocf PAYMENT DUE WITH APPLICATION NYSIF New York State Insurance Fund PO Box 66fi99,Albany,NY 12206 nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) AAAAAA 923336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 O HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC 'TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 -------------- POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 369075 07/13/2023 TO 07/13/2024 7/11/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 24494445, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:IIWWW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION-TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT ZCE FUND `Y� DIRECTOR,INSURANCE FUND UNDERWRITING IDO AcoRd CERTIFICATE OF LIABILITY INSURANCE °ATE`MM711 0''3 `THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: ROBERT S.FEDE INSURANCE AGENCYPHO IAIC,No E:rt. AJC Nv 23 GREEN STREET,SUITE 102 E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FERE INSURANCE INSU AFFORDING COVERAGE MAIC A INSURER A,ATLANTIC CASUALTY INS.CO. 324210 INSURED INSURER B Element Energy LLC INSURER C. .5HF=LTER POINT POINT -673r— DBA ELEMENT ENERGY SYSTEMS INSURER D:GENERAL STAR MAK 7470 SOUND AVENUE INSURER E: MATTITUCK,NY 11952 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. !NSR TYPE OF INSURANCE POLICY NUMBER MMIDD EFF MAY EXP LIMITS LTR1=Jum A COMMERCIAL GENERAL LIABILITY X X L1450036873 7114/2023 7/14/2024 EACH OCCURRENCE $ 3,000,000 CLAIMS-MADE [X-1 OCCUR PREMISES Ea oczurrWeal $ 1100,000 MED EXP(A are person) $ 5000 X Contractual Lia i<NA3891438 7119/2022 7/19/2024 PERSONAL 8.AOV INJURY s 3000000 GEML AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE s 3,000,000 POLICY K]PPO-JECT ❑LOC PRODUCTS-COR'PIOP AGG 3 OTHER: s AUTOMOBILE LIABBJTY COMBINED SINGLE LIMIT s Ea acddent ANY AUTO BODILY INJURY(Per person) s OWNED SCHEDULED BODILY INJURY(Par acident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE s AUTOS ONLY AUTOS ONLY Per aCCitleAl s UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED I I RETEMION S $ WORKERS COMPENSATION124494445 X I PERT ER E,R, AND EMPLOYERS'LIABILTV YIN 7/13/2023 7/1312024 TA ANY PROPRIETORIPARTNERIEXECUTIVE NIA E L EACH ACCIDENT $ 1.000000 B OFFICERIMEMBEREXCLUDED? (Mandatory In NH) EL DISEASE-EA EMPLOYEE $ If yes,desobs under DESCRIPTION OF OPERATIONS below EL-DISEASE-POLICY LIMIT J 1 Win(1100 NY State DBL DOL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Addbional Remarks Schedule,may be attaebW If more spate is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 3C day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 54375 54375 Mld,in 11971 ACCORDANCE WITH THE POLICY PROVISIONS. SouthAUTHORIZED REPRESENTATIVE RQbeets. Fede 01988-2015 ACORD CORPORATION. All rights reserved. Arson 9C I'Jn4A/A1X Tk-Arson.. ...--A I---+. :sa + +.I. ..r Alnon I08 and I08+ Microinverters INPUT DATA(OCI 108-60-2-US 108PLUS-72-2-US Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range v 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC currentz[module[so] A 15 Overvoltage class DC port II DC port backfeed current MA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA(ACI 108-60-2-US 108PLUS-72-2-US Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A 1.0 121 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 3 cycles Arms 2 Max units per 20 A(L-L)branch circuit` 16 13 Total harmonic distortion <5% Overvcltage class AC part III AC port backfeed current mA 30 Power factor setting 1,0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency N 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C222 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 108SP-DS-0002-01-EN-US-2022-03-17 ENPH• VSE. cm IQ8 and IQ8+ Microinverters Easy toi„-Aall Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- - Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter - Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times - Faster installation with simple to changing toads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. Nigh productivity and reliability Produce power even when the ��; • _ grid is dawn`' ...• ,.,:. • More than one million cumulative hours of testing � - Class ll double-insulated Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative • Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- powered PV modules and analysis software. leading limited wananty of up to 25 years. Micro Jfld-formlin9 • Complies with the latest advanced grid Support" CERTIFIED • Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily to IQ8 Series I08 Series Microinverters are UL Listed as • Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other 'Only when installed with 10 System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. '•I08 and IQBPIus supports split phase,240V IQ8SP-OS-0002-01-EN-US-2022-03-17 installations only. . . XRRe/|s �� -- '----- ------' '-- -- — - '----- ----- ---- '------ 110 Rail. �onded Splices Alowf>rofiie mounting rail The ultimate residential Aheavyweight mounting All rails use internal splices for regions with light snoxv. rail for commercial projects. for seamless connections. ` 8'npanningoopabi|it/ ^ 12'apanningoopabi|ity ^ Self-drilling screws ^ Moderate load capability ^ Extreme load oapabi|ity ^ Varying versionofor rai|n _ C|earnndb|ankfin}oh ~ C|earanVdizedfiniah ^ Formaseourebonding - PS8 (�rQi/�diog �' --- -------------------'--- ---------------- UFOs Stopper Sleeves Grounding Lugs Micnoin*mrterKits gttv P,ija ` Universal Fastening Objects Snap onto the UFO ioturn Mount K8|sorPOs 0oXR ` bond modules torails. into abonded end clamp. equipment ground. Rails. ^ Fully assembled Q |ubed ^ Bonds modules torails ~ Low profile ^ Bonds devices 0orails ^ S/ng/a, universal size ^ Sized to match modules ` Single too! installation ^ Kit comes assembled ~ Clear and black finish - Clear and black finish ~ Mounts in any direction ^ Listed to UL 2703 FllashFmot2 Conduit Mount SIPeet Bonding Hardware rN 17. Flash and mount XR Rails FIlasWd�mount conduit, esign for rapid rail Bond and attach XR Rails with superior ate n/o8 orjunction boxes. attachment. ioroof attachments. ~ Twist-on Cap eases-inmt'a|| ~ Twist-on Cap eases install ^ 8eou»a rail connections ^ T& Square Bolt options ` Wind-driven rain tested ^ VNnd-drims� rain tested ^ Slot for vertical adjusting ^ Nut uses 7/16^socket ` Mill and black fi �.finish ^ Secunea � or1"oonduit ~ Clear and black finish ^ Assembled and lubricated - P ��S ----- - --' ------ '---'--' -' ----'----- - '------'-----'�-----------'-------- - - - ' Design Assistant NABCEP Certified Training Go from rough layout to fully Earn free continuing education nnadito. � engineered system. For free. while learning more about our systems. � Fl ISD G E Flush Mount System -Rf�r ` Y ' II � a - ' 1 _.wA4`,�''"� s-.:: -w' 'f{j,,;,{�'s`.�r•`�i=::tiy� .xfP .'.l .?i'9�P �'�x.^1F�-Tj_ � =•`'.,__t.•t` y.!-' _ ..r.:i::�:,i � 'i f°f�^ Ma nj� .'�.4 .a�:. 1.,,..=H:':'S i,. _ ..Fs•'': _ " _ �:ri,' CJs',, C:=3.•%.d. - IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. .'• create, share, and price projects. UL 2703 Listed Systemnp= ' 20-Year Warranty Entire system and components meet ,5 Twice the protection offered b .. " ,� P p y newest effective UL 2703 standard. _,. __` . =: competitors. MECHANICAL SPECIRCATION =r::?e• 74.Oin x 41.1in x 1.26 in(including frame) (1879mm x 1045mm x 32mm) 6.6•(16 smm) -- ------ ---- <].6'(1°Bfimm) d 16.6•(3s"-) 48.51bs(22.0kg) 0.13 in(3.2 mm)thermally pre-stressed glass with --- - --- anti-reflection technology _. Composite film ar 'a Black anodized aluminum 6 x 22 monocrystalline O.ANTUM solar half cells S=r: 2.09-3.98in x 1.26-2.36 in x 0.59-0.71in (53-101mm x 32-60 mm x 15-18mm),IP67,with bypass diodes LAW ----------- .----- �' =a9s•p]�mm) i 4mm]Solar cable;(+)2:49.2in(1250mm),(-)>_49.2in(1250mm) .. -...-.._-._-_-_ _-.----_-_-_-.•M.-_._---... .-•- _ 4r Mamtln9sbb(DETNL A) ''; I Staubli MC4:IP68 --� '------_--'-'_-^_ -{�-1]e•t3]mml oFralA ae3•t, lemur-)r O SC Uasmn)I�1°'�I6Smm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 ,�.t., �--;t•, ---------_`----- _-j 1,ti_-�•-i'. CI=3.1?;=;8 .v -,2; -.- -- l;i PMrr [W] 385 390 395 400 405 Isc [A] 11.04 11.07 11.10 11.14 11.17 de,.. ,s- Vcc [V] 45.19 45.23 45.27 45.3C 45.34 M,-- - --- - I„pP (Ai -- - - 10.59 - 10.65 10.71 1CJ7-- 10.83 VMpp [V] 36.36 36.62 36.88 37.13 -37.39 n [%] >19.6 >19.9 >_20.1 >--20.4 -20.6 Pf.,Pr [Wl 288.8 292.6 296.3 300.1 303.8 I°c (A)" - -- 8.90 ----- 8.92 8.95 8.97 9.00 V [V1 42.62 42.65 42.69 42.72 42.76 - impp [A] 8.35 8.41 8.46 8.51 8.57 -------------- v VMPP [V] 34.59 34.81 35.03 35.25 35.46 ,Measurement tolerances Pv°°±3%;I so;Voc±5%at STC:1000 W/m],25±2°C,AIM 1.5 according to IEC 609C4-3•78GC W/m],NMOT,spectrum AM 1.5 - 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOVY IRRADIANCE Atieest98%Oframiralpower during first year.Thereafter max.0.5% --------- -------------- degracatienper year.Atleast 93.5% �.,a°---------------- t of nominal power up to 10 years.At least 86' of nominal power up to ---- 25 years. = 9°--------- ----------'-----= a All data withic measurement toleranc- es.Full warranties In accordance with aa° aoa 1°aa s [ the warranty terms of the O CELLS o ria..•sales organisation organisation of your respective o „ as country. , Typical module performance under low irradiance corditiens in v comparison to STC conditions(25°C,1000WJm2) m TEMPERATURE COEFFICIENTS o a [%/K] +0.04 _ [%/Kl -0.27 -.".._ ._.. _ y [%/K] -0.34 s,. -, :r=3;: ;-:.. __ NMOT [*Fl 109±5.4(43±3°C) c PPOPE;2 i lES rCIR S 1STEVi O✓=S;GN ° --- w •:a::"6'^ _ _3+?7 tin,:;r° _ [V] 1000(IEC)/1000(UL) 4v s cassi%`caa Class II o r-; ala;d„w,r"Sa. . rsa:ia:.ro [A DC] 20 � ._:hM ba ad or,.t,`Si!'_ .3.L7-',C TYPE,2 � w Sia '--signi_a.0't n;? •;= [IbS/ft]] 75(3600 Pa)/55(2660 Pa) =d)„Ictus=Tsr:roarscur; -40°F up to+185°F o mus, ; 3 ;crtthuoz;e Duty (-40°C up to+85'C) a::.7as;Lead•, Pull [lbs/ftq 113(540OPa)/84(4000Pa) m m See Installation Manual v CURL'riCA';Ci�13 .ASICC aT] iCsITES PA ;`,101VG !N;OR1NIATION _ m UL6i73QCE-compliant, f`/Ia cI�/I fes'%I rte• 1 ��� m Quality Controlled PV-TUV Rheinland, iA, lo4y�'I" feyyl ") Iee!!yJ" U rQ-p� aQHC � n IEC 61215:2016,IEC 61730:20161 G® �� -- --"- --_-- ---_--------_-----.-_---___.-- m U.S.Patent No 9,893,215(solar cells), nmm�°m,° ";; 76.4 in 43.3 in 48.0 in 1656lbs 24 24 32 OCPV Certification ongoing. C US 1940mm 1100mm 1220mm 751kg pallets pallets modules u�ena6 mimzl°in o n w Nate:Installation,instructiers must t;e followed.See the,rstallaticn ar.d operating manual or contact cur techrical service departmert for further mformatler cr approved:installation and use of this product. HarlwBa G CELLS America Inc. 400 Spectrum Center Drive,Suite 14CO3 irvine,CA 92618.USA I'_.-1949 748 59 961_,,+d .inquiry@us.q-cells.com I nr53 www.a-cells.us Milo powered by _' . {p ------- - i�-C�R$'i,CIAfBBSt'- �d Q CELLSWarran� �Q29 Rq Uct 3Pe6o-. vieio SacurAv a'REAKhNlG T420'A 1'zP;CIcNCY BARRIER AQ.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. 7%4G-NICST T:,iCRGUGH TESTING PROGRANINIE IN TF'E r^fOUSTa'Y _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of 4� the independent certification institute TUV Rheinland. Pi:\I%DVLjIVE A ._ PtE.:r'�-R .=:H1i iGLCGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. ^•ID_I-fAI H:GL- =RP0R?41A:N CE Long-term yield security with Anti LID Technology,Anti PID - Technology',Hot-Spot Protect and Traceable Quality Tra.Qn". High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). Inclusive 25-year product warranty and 25-year linear performance warranty2. 'APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) 2 See data sheet on rear for further information. THEIDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany L L IS Town of Southold September 6th, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Byrne Residence, 1100 Theresa Dr, Matittuck, NY 11952 To Town of Southold I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 130 mph, 3 second gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.8 pounds per square foot. Please contact me if you have any questions or comments about the above. Si cerely, James erkoski, PE ���'yo 260 Deer rive Q� ��? ERA- 260 Mattituck, Y 11952 631-774-7355 "" w 725 ASO S` �P SCOPE OF WORK DESIGN 8 DRAFTING BY: soulhold �. ELEMENT ENERGY LLC TO INSTALL A 12.555 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT BYRNE RESIDENCE, a a REVIEW BY J.M.NABCEP CERTIFIE LOCATED AT 1100 THERESA DR, MATTITUCK, NY 1 1 952. a e, 051 1 1 2-1 29 Pemmc THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH APPROVED AS NOTED THE EX15TING ELECTRICAL SERVICE EQUIPMENT. REVISIONS DATE-/0-5-.2-5 B.I' - DE5CRIPiION DATE REV ORIGINAL 09-15-2023 SYSTEM RATING FEEA2a BY C=6.g. NOTIFY BUILDING DEPARTMENTAT 12.555 kW DC 5TC 631-765-1802 8AM TO 4PM , ..' � Noyack FOR THE �__ ►_ - :._rnannuk nlewserrak FOLLOWING INSPECTIONS: 1- FOUNDATION-TWO REQUIRED EQUIPMENT SUMMARY FOR POURED CONCRETE 2. ROUGH-FRAMING BPLUMBING 31 QCELL Q.PEAK DUO BLK ML-G 10+405 WATT PV MODULES 3. INSULATION ;/ 31 ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS FINAL-CONSTRUCTION MUST _--_Jameaport 4. Aquebugue CONTRACTOR I IRONRIDGE XP 100 MOUNTING SYSTEM BE COMPLETE FOR C.O. 4 AMESran ELEMENT ENERGY, LLC. North Sea 5 H EET INDEX ALL CONSTRUCTION SHALL MEET THE 7470 SOUND AVE MATTITLICK, NY I 1 95 Pv—I COVER REQUIREMENTS OFTHE CODES OF NEW' PROJECT LOCATION LICENSE # G74G I-111 PV-2 SITE PLAN YORK STATE. NOT RESPONSIBLE FOR PV-3 ROOF LAYOUT LICENSE# 52689—ME DESIGN OR CONSTRUCTON ERRORS PV-4 STRUCTURAL/DETAILS 4-SECTIONS PV-5 3-LINE ELECTRICAL DIAGRAM PV-6 LABELS { GOVERNING CODES COMPLY WITH A.LL CODES'OF OCCUPANCY OR x= . :. NEW YORK STATE & TOWN CODES USE IS .. 2017 NATIONAL ELECTRICAL CODE. . 2020 RESIDENTIAL CODE OF NEW YORK STATE. AS REQUIR AND-CONDITIONS OFA. NLAWFUL .. 2020 FIRE CODE OF NEW YORK STATE. cn1rruly�7 WITHOUT A5CE 7-16 AND NEPA-70. SOUMUT OZBA. CERTIFICATE UNDERWRITERS LABORATORIES(UL)STANDARDS OF OCCUPANCY OSHA 29 CFR 1910.269 Y GENERAL N OTE5 SOUtliapTOWN; PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT N+Y:SCDEC= RETAIN STORM WATER RUNOFF ° ep LL1 W N THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE PURSUANT TO CHAPTER 236 °' w U > LCA HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK (y) AGREE THE SAME. OF THE TOWN CODE. AERIAL VIEW w o -_ 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COM M ENT5 AND APPROVAL STAMP �' cn N INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTORRK 'S LIABILITY, WOMAN'S COMPENSATION, . ,;„.-: a (f� W Z AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. g W COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES 0 W 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE ANDfl OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO = U ALL RULES AND REGULATIONS OF THE RESPONSIBLE , D COMMENCING WITH WORK. ti •�- "`�; _�• '1.--- w W JURISDICTION. -` "��'" �"�"• 1 I 1 . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR (n Z 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS ! O O Q WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB 517E DURING THE THE CONTRACTOR SHALL STOP WORK AND NOTIFYTHE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS O ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND w co — CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. THI5 SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, 5. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SHEET NAME OF New y I SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT COVER FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 CONSTRUCTION. I f� - �DL=ER O,Q I SPECIFICATIONS. co �� n• �p /r j 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING r �” NYS CODES t. REGULATIONS n CONDITIONS PRIOR TO ORDERING MATERIALS AND 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN 2 - - COMMENCING WITH WORK. CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S DRAWING SCALE d? 3rnr CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS �O 0 50 ti Q,'� 6. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE APE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON A;'OFES N N .T.5. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK,THE SITE TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE \ EXTENSIONS TO THIS PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF I \ SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. J EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS PV- I RESULT OF HIS WORK. TAX MAP: 1000-1 15-00-13.00-015.000 50LAR ARRAY ON MAIN HOU5E 12.555 tW (3 1)QCELL Q.PEAr.DUO BLr.ML-G 10+405 WATT PV MODULES DESIGN 6.DRAFTING BY: (1)STRING OF(1 3)MICRO-INVERTERS.(1)STRING OF(1 2)MICRO-INVERTERS s(1)STRING OF IG)MICRO-INVERTERS ELEMENT ENERGY LLC '(3)STRINGS TOTAL REVIEW 3Y J.M.NABCEP CERTIFIE 05)1 12-123 STRING #I r-- ------------ - - - - - _ - - - - - _ _ - MICRO-INVE108P FELUR E,l,ASE 5-72 2-US REVISIONS 1 240 VAC.1.21 A DESGRIFTON DATE REV -- ----------- _ IGINAL09-15-2023- - ___ 97?o CFC-WEIGHTED EFF. -___ NEMA 6.UL U5TED TYPICAL - - I STRING#2 - ---- - - - -- - - --- ------------- ------------- ------------ ---- OIAR MODULE iIPCAL --- ---__-_-- TO UTILITY GRID I I I STRING #3 = _ = r LE 1 I ------- - ENPHA5E BI-DIRECTIONAL CONTRACTOR I r - - - _ _ - _ - BRANCH UTILITY METER I I TERMINATOR 1-PHA5E.240V I --------- ELEMENT ENERGY, LLC. *- - _ _ TYPICAL 7470 SOUND AVE - ' aoulrO^mrRauuErno° MATTITUCK, NY 1 195 EI!'HlSE 3RANCH PE4 I IEC 2a0.21;Bx l.690 64(AI I I I CIRCUIT:A51_-TYPICAL _116TH 0`TA^-COI1000r0R5 I I i SnA�IlorExCEED'D`i LICENSE # 6746 I-HI I LICENSE # 52G89-ME I � I I ,v....A :..,- l I I � I � I , , I AC COMBINEP.Box l r --�T I I I MAIN SERVICE PANEL AC DISCONNECT PROJECT NAME 50 D D2231 R3 N �/ LL 1 24O vac GOA W L1J (�I 1 IIElMIA 3R.UL 1_15TED 0 �(V� ' ;21 50 A F 5E5 G I 11 ( 1 r>_Lr.� L1) 50 A i I EXISTING GROUNDING G v (5)m ELECTRODE 5Y5TEM H I� E) Q Q MY _____________________________J L------------------------------------------- LL1 W "'- WIRE t.CONDUIT 5CHEDULE = U 'IRC'JiT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(17 � W I.D.# ORIGIN D`5TINATION SIZE PER PDLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION ;CU/AL) TYPE SIZE TEMP DEBATE DISTANCE O z O 310.15(13)(3) 310.15(131(2.1](3.) INVERTERS COMBINER PANEL AWG#12 1 G I U5E-2/PV Wlre AWG#8 1 BARE CU FREE AIR 1" 55-C 0.84 80 FT 2.09 D_ O OR EMT O 2 COMBINER PANEL AC D15CONNECT AWG#8 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45°C 005 25 FT 0.5% D_ CD 3 AC DISCONNECT MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I.. 45QC 0.95 10 FT 0.2% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampaclty Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 909C WET ENVIRONMENT. [NEC G90.8(B)(I)]: (Isc) '(#of strings)'(I.5G) = 19.GG AModuler StrinOF NE 3-LINE DIA. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY AWG#12,ampacity'Temp Derate = 20.1 G A es pg 13 MAX. '� TO.AND LOCATED AS CLOSE AS P0551BLE TO THE NEAREST RIDGE. HIP•OR VALLEY. Modules per Inverter I Q 20.I G A >19.GG A.therefore AC were size Is valid. 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL EFR #2 Inverter Output Wire Ampacity Calculation Number of Inverters 3 1 <^ i' �O COMPLY WITH NEC 110.26. g,e Inverter Max Am era e output' (1.25) = 4G.89 A Record low tem -102C N 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR 5FIALL P g P P ;� • AWG#8,ampaclty'(Temp Derate)'(Condult FIII Derate)= 52.25 A Voc Tem Coefficient -0.24%/eC f DRAWING SCALE FURNISH ALL NECESSARY OUTLETS.SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL P 0 � 52.25 A>46.89 A, therefore AC were size Is valid. APPLICABLE CODES AND STANDARDS. DC SYSTEM SPECIFICATIONS � G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampaclty Calculation 41 [X I . . O eratln Current 10.8 A N I v Inverter Max Am era e output' 1.25)= 4G.89 A Y'�i _ THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. P 9 P ( �� � � 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G.ampaclty'(Temp Derate)'(Conduit FIII Derate)= 71.25 A Operatinq Voltacle 37.4 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A> 4G.89 A.therefore AC wire size 1s valid. Max.System Voltage 49.G V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. Short Circuit Current 14.0 A �S 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEK LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR IL5CO GBL-4DBT LAY-IN LUG. Max AC Output Current 46.89 A 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) PV-5 OR Operatinci AC Volta e 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000- 1 15.00- 13.00-015.000 CONSTRUCTION SUMMARY DESIGN 4 DRAFTING BY: (3 1)QCELL Q.PEAK DUO BILK ML-G 10+ 405 WATT PV MODULES N ELEMENT ENERGY LLC (DIMENSIONS: 74"X 4 1 .1"X 1 .3") EW PV AC D15CONNECT 0° REVIEW BY J.M.NABCEP CEP.TIFIE I (3 I) ENPHASE IQ8PLU5-72-2-US MICRO INVERTERS 051112-129 (STING UTILITY METER (G8)ATTACHMENT POINTS @ G4"O.C. MAX. (258.8) LF IRONRIDGE XR 100 MOUNTING SYSTEM. ---I ' G I" --1 ' 7 1 11 I5TING MAIN ELECTRICAL SERVICE PANEL W270° REV1510N5 ROOF TYPE: ASPHALT(SINGLE LAYER) 2 4 �90o DE5CRIPTION DATE I REV CONSTRUCTION NOTES %' ® ® 240° D 120° E ORIGINAL 109-I5-2023 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE / 210° 150° WITH THE MANUFACTURER'5 INSTALLATION INSTRUCTIONS. BRAY#2 180° Jil 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH —ARRAYI !G MODULES S 9 MO,DUYES MINIMUM NEMA 3R RATING. 2G-° PITCf. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE 26° PITCH 770 AZIMUTH FIELD VERIFICATION. 2570 AZIMUTHEg I ED m / I CONTRACTOR ED �� ELEMENT ENERGY, LLC. i> 'a TRING/CONNECTION TYP. in v PANELTYP. 7470 SOUND AVE MATTITUCK, NY 1 1952 ;m ;m;N �7 ICRO-INVERTER TYPLICENSE# G74G I-HI b � � �1 . %> :>% LICENSE # 52G89-ME O � 36"x 30 GROUND ACCESS TYP. PROJECT NAME LLJ O LLJ > mmLf-) ACCESS ROOF 2 W cz (y) Q ui/ g w R z I8"'FIRE SETBACK @'NDGE� / /�/ '18'FIRE 5ETBACK @RIDGE� 1/ c)11" Lu = U ARRAY_#4 8"- __811 ARRAY##3 z �3 MOD.ULE 3 ODULES O Ir- o Ir- 45° CH PIT450 PITCH LEGEND — Q 167°AZIMUTH I G70 AZIMUTH ®DOSTING UTILITY METER rL CD o MAIN SERVICE PANEL `✓ NEW PV SUB-PANELS A/C DISCONNECT COMBINER SHEET NAME INVERTERS O '!� NE(j, �P GND ELECTRODE PV MODULE FV LAYO U T �E �0 �.� —RACIGNG RAIL o ATTACHMENT POINT r � � --RAFTERS Lu DRAWING SCALE PROOF PITCH ANGLE NCO � O ®i SUNRUN METER 07250I/QII = I I-OII A VENT (CJl 'NOTE �Of'ESS�ON OpLUMBING VENT 1 .)THE ROOF 5ETBACK/PATHWAY SHALL NOT BE ®sur LIGHTREQUIRED ON ROOF-SLOPES WHERE THE SHEET NUMBER OPPOSING OR ADJACENT ROOF SLOPE I5 AN ®CHIMNEY ACCESS ROOF IN ACCORDANCE WITH R324.G.I ®COMPOSITE SHINGLES PV-3 GOOD CONDInON EXCEPTION OF 2020 NYS RESIDENTIAL CODE. TAX MAP: 1000- 1 15.00- 13.00-015.000 ❑rniM/IREMOVE ASNNEISSUES CESSAR LEGEND o EIOSTING UTILITY METER N TAX MAP: 1000-115.00-13.00-015.000 DE E1GN 4MENITDEN�ERGY LLC FTING BY: ®MAIN SERVICE PANEL Oo EW PV AC DISCONNECT REVIEW BY J.M.NABCEP CERTIFIE NEW PV SUB-PANELS 051 1 12-120 A/C DISCONNECT I ---- -- I G'-54" --- --- — --- --I G'-5j-Lzrol I5TINGUTILITY METER 11 1 INVERTERS �/ 21 GND ELECTRODE '• 27O°Q g ® I5TING MAIN ELECTRICAL SERVICE PANEL REVISIONS PV NODULE �`��° DE5CRIPTION DATE I REV 240° ORIGINAL 09-15-20231 —RAOGNG RAIL 210 D 120° 0 ATTACHMENT POINT 180150o 0 ---RAFTERS PROOF PITCH ANGLE aSUNRUN METER NST 0PLUMBING VENT i ®SKY LIGHT Via_ ®CHIMNEY im CONTRACTOR ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. ❑GOOD CONDITION im POTENTIAL SHADING ISSUES 3 i'n 'n 7470 SOUND AVE IMM/REMOVE AS NECESSARY 3 I '-3a' ,� ,� �� MATTITUCK, NY 1 1952 �N LICENSE# G74G I-HI �D D LICENSE # 52G89-ME j O / 36"z 36"GROUND ACCESS TYP. / PROJECT NAME u- Lu LNn ACCESS 2 W W Q , / g w � z/ - / 1 8"'FIRE SETBACK @RIDGE / / 18"FIRE SETBACK @RIDGE ////// O / W Y C) W F— CD — 20'-3" 20'-3" SHEET NAME P� c)A DEEwyEy 0 SITE PLAN ,� 'NOTE 1 .)THE ROOF SETBACK/PATHWAY SHALL NOT BE `- �'• REQUIRED ON ROOF-SLOPES WHERE THE m ," >L DRAWING SCALE OPPOSING OR ADJACENT ROOF SLOPE 15 AN ACCESS ROOF IN ACCORDANCE WITH 8324.6.1 cP � a4. \ �OA e 252 ��� I/VII = I I—OII EXCEPTION OF 2020 NYS RESIDENTIAL CODE. ROPES 0 P� CONSTRUCTION NOTES 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NUMBER MANUFACTURER'S INSTALLATION IN5TRUCTION5. FV-2 ` /_n C 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R v RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. LOAD CALCULATION ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 ITEM DESCRIPTION ARRAYS#1-2 DESIGN 4 DRAFTING BY: RB Kicleie Beam/Board 2"X 10" D. FIR ELEMENT ENERGY LLC REVIEW BY J.M.N MODULE WEIGHT(Lbs) 48.4 48.4 48.4 48.4 R Rafter 2"X 8" D. FIR I G"O.C. 12-129 229 CERTIFIE (D) Deckin 5/8" PLYWOOD 051 1 1 2-1 29 #OF MODULES 9 16 3 3 P Pitch 20 t.45° REVISIONS TOTAL MODULE WEIGHT(Lbs) 435.6 774.4 145.2 145.2 (J) Cedincl Joist 2"X 8" D. FIR P I G"O.C. DESCRIPTION DATE DATE REV TOTAL LENGTH OF RAIL(Ft) 84.3 91.3 20.8 20.8 (K) Knee Walls 2"X 4"D. FIR I G" O.C. 1 C Collar Ties 2"X 4" D. FIR I G"O.C. ORIGINAL os-1 s-zozs'1 RAIL WEIGHT PER FOOT(Lbs) 0.68 0.68 0.68 0.68h Horizontal S an of R 180" MAX. (RB TOTAL RAIL WEIGHT(Lbs) 57.3 62.1 14.1 14.1 (� #OF 5TRANDOFF5 20 32 8 8 (D) WEIGHT PER STRANDOFF(Lbs) 2 2 2 2 TOTAL STANDOFF WEIGHT(Lbs) 40 64 16 16 TOTAL ARRAY WEIGHT(Lbs) 532.9 900.5 175.3 175.3 POINT LOAD(Lbs) 26.6 28.1 21.9 21.9 CONTRACTOR TOTAL ARRAY AREA(Sq Ft) 192.7 342.6 64.2 64.2 ELEMENT ENERGY, LLC. 7470 SOUND AVE ARRAY DEAD LOAD(Lbs/Sq Ft) 2.8 2.6 2.7 2.7 MATTITUCK, NY 1195 I LICENSE # 6746 I-HI WIND DESIGN SUBJECT TO DAMAGE FROM j (P (C) LICENSE# 52G89-ME GROUND I SEISMIC WINTER ICE BARRIER FLOOD AIR I MEAN SNOW DESIGN Frost DESIGN 1 UNDERIAYMENT 1 5 FREEZING ANNUAL LOAD° Speed" Topographic Special 1 Windborne CATEGORYr• TEMP` REQUIREDh HAZARDS INDEXi I TEMP) (mph) effectsk wind region debns zone'" Weathering' kine b Termite` (K) depth MOD TOFEMA 20 140 NO NO NO B SEVERE 3 FT 1 5°F YES 599 5 1°F HEAVY ZONE X MANUAL J DESIGN CRITERIA" Indoor Winter Summer desi n Heating temperature Elevation Latitude Altitude correction factor e Design temperature cooking i 1 heating cooling �, � tempera 1. difference J) ture i 108 FT 4 1°N 15°F 86°F 1.00 70-f 75°F 55°F Wind Wind Winter PROJECT NAME Coincident ] Cooling temperature difference velocity velocity Daily range Summer humidity - j wet bulb humidity heating cooking ROOF FRAMING DETAIL I 0O W ILJ CV L Ln 1 5°F 15 MPH 7.5 MPH 72'F MEDIUM(M) 1 40% 32 GR @50%PH I/ 131) w Z C) - For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. LU _ Q Q a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth U) _ ( }- strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as 0-/ W Z determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or 0652. MODULE MOUNTING CLAMP .1 OL LLj b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction O shall fill in the frost line depth column with the minimum depth of footing below finish grade. SOLAR MODULE = U c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. � W d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined 5TAINLE55 STEEL 3/8" nIr- on a site-specific basis in accordance with Section R301.2.1.4. BOLT AND NUT 0 ,z^// 0 e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent Values for winter from Appendix D of the Plumbing Code of New York a- L L C ]- State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also �- - Q see Figure R301.2(1).] CD - f. The jurisdiction shall fill in this partof the table with the seismic design category determined from Section R301.2.2.1. NRIDGE ALUMINUM RAIL ,r. 1} g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New ALUMINUM°L"BRACKET York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the �1 SHEET NAME Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: t1 ALUMINUM FLASHING i.The accompanying Flood Insurance Rate Map(FIRM), ii.Flood Boundary and Floodway Map(FBFM),and j iii.Related supporting data along with any revisions thereto. OF 1�[; STRU CTU RAL The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ASPHALT SHINGLE ROOF 5/1 6°x 6° 's D E y0 effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." STEEL LAG OL ^ RSO i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) 2 1/2"MI 7�E 1,5 value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." PENET-A DRAWING SCALE j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method WITH GE 4 00 (Base 32°F)" (EQUIVAL B R) Lu k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the AS NOTED jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. N r � I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with ��A �7 2 ��� "YES"and identify any speck requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. P_ m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the SS1 table. SHEET NUMBER n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J or established criteria determined by the \ jurisdiction. 1 P V/ -4 o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. TAX MAP: 1000- I 15.00-13.00-015.000 MOUNTING DETAIL (') See Figure R301.2(4)B. SERVICE METER O O INSTALLATION NOTE DESIGN 8 DRAFTING BY: ELEMENT ENERGY LLC - - "--'--'-"-"'"-""" ----"-"--'-'--"-' REVIEW BY J.M.NAB''EP GERTIFIE ® O SOLAR PV SYSTEM g PHOTOVOLTAIC Y PHOTOVOLTAIC ( I ) ALL LABEL SHALL BE INSTALLED IN 051112-129 SOLAR BREAKER EQUIPPED WITH - - • DISCOACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® •• • D REQUIREMENTS. RevlsloNs ESCPJPiION 1 DATE REV OPERKI ING CURRENT A (2) ALL LOCATIONS ARE APPROXIMATE AND MAX SYSTEM VOLTAGE VDC ORIGINAL i09-14-2023 SOLAR AC LOAD CENTER- OUTSIDE , C DONOT RELOCATE THIS SHORT OIRCUIT CURRENT A REQUIRE FIELD VERIFICATION. I �OVERCURRENTDEVICE-`d (3) LABELS, WAKNING(S) AND MARKING j O SHALL BE IN ACCORDANCE WITH NEC TURN RAPID SHUTDOWN SWITCH TO 9 1 10.2 I (B). THE'OFF"POSITION TO SHUT DOWN I PV SYSTEM AND REDUCE CAUTION SHOCK HAZARD IN THE ARRAY ELISCONNECT POWER TOTHIS SERVICE ISALSOSUPPUED (4) THE MATERIAL USED FOR MARKING --- -- -- - FROM TIE FOLLOWING SOURCES WM DISCONNECTS LOCATED AS SHOWN MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER- INSIDE O UII YNETEMAHEGE ER COMPLIANCE WITH NEC 110.2 I (B)(3). ® 8IN THE GNtFGE CONTRACTOR PV BRET I 1a=R I j PV ,�' (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLC. W - NING 7470 SOUND AVE ® 0 ® I I ® OWARNI'N TTP. ! SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 195 7MAIN UIPMENTFEDBYMULTIPLE DUAL POWER SUPPLY ES.TOTAL RATINGOFALL j a, LICENSE # 6746 I-III RENTT'A S,EXCLUDING SOURCES:uTtuTYGRID COMPLIANCE WITH NEC 690.3 I . SUPPLYOVERCURRENTAND PV SOLAR LICENSE # 52689-ME DEVICE,SHALL NOT EXCEED ELECTRIC SYSTEM O CONDUIT - INSIDE BUILDING /unPL7OFBUSBAR J 0 1110011 { WARNING WARFP�ANEL G I THIS SERVICE METER t I IS ALSO SERVED BY A ELECTRIC SHOCK HAZARD i PHOTOVOLTAIEM PHOTOVOLTAIC SYSTEM TERMINALS ON THE LINE AND 1 COMBINER _ LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS CONDUIT - OUTSIDE BUILDING IN THE OPEN POSITION - O © PROJECT NAME ® " • • • ' WARNING '• • o Lu j Ln DUAL POWER SUPPLY SOURCES:UTILITY GRID AND z C w I PV SOLAR ELECTRIC SYSTEM (j LuA CAUTIONNSOLAR CIRCUIT W — MAIN SERVICE PANEL - OUTSIDE O >- 5 ;! � � Z g W O O O A CAUTION_ ?' 0) = U SOLAR ELECTRIC SYSTEM CONNECTED c� LU 6 • • • ' O O O MAIN SERVICE PANEL - INSIDE { WARNING CD I POWER SOURCE { OUTPUT CONNECTION I ® O I DO NOT RELOCATE THIS 1, SPIFFY NAME OVERCURRENT DEVICE !I O �,Ew LABELS F P � IDC. l-O AC D15CONNECT/BREAKER ` 'P DRAWING SCALE I 3 9 cu O.O O 50 RO s,, P� JSHEET NUMBER TAX MAP: 1000-1 15.00-13.00-015.000 50LAP ARRAY ON MAIN HOUSE 12.555 kW (3 1)QCELL Q.PEAr,DUO BLr,ML-G 10+405 WATT PV MODULES DE51GN B DRAFTING BY: (1)STRING OF(13)MICRO-INVERTERS,(1)STRING OF(1 2)MICRO-INVERTERS 4(1)STRING OF(G)MICRO-INVERTERS '(3)STRINGS TOTAL ELEMENT ENERGY LLC REVIEW BY J.M.NABCEP CERTIFIE 051112-129 STRING#I _ _ r- ------------ - MICRO-INNER ER REVISIONS IQ8PW5-72-2-US 1 240 VAC.1.21 A DESCRIPTION DATE REV --- --- -- --- --- --- --- --- --- NEM G,UL EILIGHTED EFF. --- NEMA 6, STED ORIGINAL 09-15-20231 TYPICAL I I STRING#2 I 1 r------------ - I OLAR MODULE TYPICAL TO UTILITY GRID 1 1 I STRING#3 _ _ 1 N r- -------- - - - - - BRANCSHE O BI-DIRECTIONAL CONTRACTOR I TERMINATOR O UTILITY METER 1 1 *- ---------- TYPICAL I-PHA5E,240 V ELEMENT ENERGY, LLC. 1 I ( , N 7470 SOUND AVE ENPHA5E BRANCH POu1T of urt5Roolulecrloll CLRCurr CAB'F TYPICAL LM1GT1 FTAFC IIDUCT90.64(A) MATTITUCK, NY 1195 5'�NO.2X=101 � LICENSE# G74G 1-HI I LICENSE # 52G(59-ME I i I I 1 1 I I 1 VAC 5 2 Dj A nscouve I I z4ov.zrA I I I 1 I I I I I I 1 AC COMBINER BOX GAT54AY vav-cevv�.c>,..-_ ce -- 1 1 I 1 I MAIN SERVICE PANEL I 1 AC DISCONNECT T_' �`J°A= PROJECT NAME 50 D D22311M N 2J=A 11 ' 1 240 VAC,GOA lLJ !�I IIMIA 3P„ULU L U5MD \V N 1 (2)50 A FU5E5 G i O Ln 50 A I I EXISTING GROUNDING ` v IV In, ELECTRODE 5Y5TEM ILJ Q _ I _ i -� Q ------------------ _ ---- . ---------------------- ---------------------------- g w z i-----------------------------------------�-- .. WIRE CONDUIT SCHEDULE O0 CZ W o = U CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% W W I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE DISTANCE n O 1- 310.15(8)(3) 310.i 5(B)(2aX3.) I INVERTERS COMBINER PANEL AWG#12 1 G I USE-2/PV W1re AWG#8 1 BARE CU FREE AIR I" 55QC 0.84 80 FT 2.0% Q OR EMT O 2 COMBINER PANEL AC D15CONNECT AWG#8 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45-C 0.95 25 FT 0.5% 3 AC D15CONNECT MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC P. 45-C 1 0.95 10 FT 0.2% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. [NEC G90.8(B)(1)]:(Isc)'(#of strings)'().5G) = 19.GG A Modules per Strin F 3-LINE DIA. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY p 9 3 MAX. U NF TO,AND LOCATED AS CL05E AS P055115LE TO THE NEAREST RIDGE,HIP,OR VALLEY. AWG#12,ampaclty'Temp Derate = 20.I G A "< <'1/ 20.I G A>19.66 A,therefore AC were size 1s valid. Modules per Inverter I Q' �S E'F � U 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL � 0 COMPLY WITH NEC 110.26. #2 Inverter Output Wire Ampacity Calculation Number of Inverters 31 � ekO Inverter Max Amperage output' (1.25)=4G.89 A Record low tem I OQC F A N 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL p FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE55ORIE5 TO FULFILL AWG#8,ampacity'(Temp Derate)"(Conduit Fill Derate) = 52.25 A Voc Temp Coefficient -0.24%/QC n DRAw1NG SCALE 52.25 A>4G.89 A,therefore AC wire size is valid. APPLICABLE CODES AND STANDARDS. DC SYSTEM SPECIFICATIONS 7 i LLl G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation O eratln Current 10.8 A THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. (1.25) N N T Inverter Max Amperage output' = 46.89 A K;x _ v 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G,ampacity'(Temp Derate)'(Condult Fill Derate) = 7 1.25 A O eratln Voltacle 37.4 V O 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A>4G.89 A,therefore AC wire size is valid. Max. System Voltage 49.G V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEER LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR IL5CO GBL-4D5T LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) Max AC Output Current 46.89 A PV-5 OR O eratln AC Voltale 240 V 10.)THE DC SIDE OF THE PV SYSTEM IS UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000-1 15.00-13.00-015.000 , J Town of Southold September 6th, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Byrne Residence, 1100 Theresa Dr. Matittuck, NY 11952 To Town of Southold I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 130 mph, 3 second gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.8 pounds per square foot. Please contact me if you have any questions or comments about the above. Since ly, �G OF New Y C 5 CHEF O James Deerkoski, f:Rio -per 260 Deer Drive �� Y • x Mattituck, NY 11952 m 631-774-7355 OA O 5 �O SSIO P�