Loading...
HomeMy WebLinkAbout49720-Z �o�ag�EFOI�-�oGy Town of Southold 11/18/2023 o P.O.Box 1179 co A} 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44757 Date: 11/18/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 5660 Sound Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 121.4-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/18/2023 pursuant to which Building Permit No. 49720 dated 9/19/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: additional roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Carlson,Jeffrey of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49720 10/18/2023 PLUMBERS CERTIFICATION DATED Auth riz d Signature �aSUEFoi,t�� TOWN OF SOUTHOLD Gy BUILDING DEPARTMENT TOWN CLERK'S OFFICE I oy • � �5{ SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49720 Date: 9/19/2023 Permission is hereby granted to: Carlson, Jeffrey 5660 Sound Ave Mattituck, NY 11952 To: install additional roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 5660 Sound Ave, Mattituck SCTM #473889 Sec/Block/Lot# 121.4-2 Pursuant to application dated 8/18/2023 and approved by the Building Inspector. To expire on 3/20/2025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector pf SO!/j�,ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(D-town.southold.ny.us Southold,NY 11971-0959 Q�yCOUNT`I,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jeffrey Carlson Address: 5660 Sound Ave city:Mattituck st: NY zip: 11952 Building Permit#: 49720 Section: 121 Block: 4 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: SunRun Installation License No: 33878ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency StrobeHeat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 4.68kW Roof Mounted PV Solar Energy System w/ (12) Trina Solar 390W Modules, AC Disconnect, Enphase Combiner, Solar Edge Inverter, 200a Panel 30 Circuits / 19 Used Notes: Solar & Service Upgrade Inspector Signature: - Date: October 18, 2023 S.Devlin-Cert Electrical Compliance Form q SOUIyo� # * TOWN OF SOUTHOLD BUILDING DEPT. r Imo, cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ Vf FINAL 961e?, -- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL n REMARKS: DATE 1.0- 1 e' INSPECTOR � �pr.sntill to 1 �oo TONOF * # SOUTHOLD BUILDING DEPT. couto, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Q 402 Ae V(2 DATE INSPECTOR /■' MIGHTY 0 GT 3 1 2023 ■ ENGINEERING CO. DRIVEN TO EXCEED EXPECTATIONS guild°ss�s����,a;tatzesa4 ©gran 0,J� r;�rJld October 13,2023 Subject: Post Installation Approval Letter Job Number: 216R-660CARL Client: JEFFREY CARLSON Address: 5660 SOUND AVE,MATTITUCK,NY, 11952 Building Permit:49-7-28- L1q� IQ) To Whom It May Concern The purpose of the review was to verify the installation is in conformance with the approved plan set and that any potential modifications from those plans meet the intent of the approved plan set. I certify that the PV racking system's attachments have been observed to be installed in conformance with the approved plan set. The installation complies with the code provisions listed below. -2020 NEW YORK STATE RESIDENTIAL CODE WITH 2018 IRC/IBC/IEBC ASCE Version 7-16,NEC 2017,NDS 2018 • Basic Wind Speed V= 128 mph,Exposure:B • Ground Snow Load=25 Psf Sincerely, ofNEWyA :3A54 igitally signed by y4p'BEY KAN,,,, * D� Aumphrey K. Kariuki m ate,2023.10.13 a 095450 3 -04'00' R�FEsSIONP Mighty Engineering Co 1708 Roxborough Rd Charlotte, NC 282111(980)689.9776 1 info@mightyengineeringco.com ?IELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) ------------------------------------ L+ � FOUNDATION (2ND) z c � O v1 O H ROUGH FRAMING& PLUMBING ^� p1� r r� INSULATION PER N.Y. STATE ENERGY CODE 0 C. FINAL ADDITIONAL COMMENTS o w� 0 z x e r� b �. �� �— c�c�o CA�►2� ° °luso TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax(631) 765-9502 hgps•//www.southoldtownny.Rov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ® E C E D 1J E PERMIT NO. Building Inspector: _ AUG 18 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building Department Owner's Authorization form(Page 2)shall be:completed. Town of Southold Date: -/�•d3 OWNER(S)OF PROPERTY: Name: . G CXl SCTM#1000- n_l Project Address: 5"U Phone#: t.0 S1 a-7 _I M Email: bh j, ; ®V Mailing Address: J5�p(.00 Sou 4J- R-04 CONTACT PERSON: r' - Name: Mailing Address: 02h ' Z g (� Phone#: q29 35 Email: �,�j X- n/CJ.17 C�. DESIGN PROFESSIONAL,INFORMATION: Name: 1/ 10 Mailing Address: 9cJkbJrdJ 'lCl a� L Phone#: Q� Email: CONTRACTOR INFORMATION: / Name: sr l[ `e1, Mailing Address: �' 04 ft' b(✓�� Phone#: F Email: DESCRIPTION-OF PROPOSED CON STR ON... ❑New Structure ❑Addition teration ❑Repair ClDemolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes ER60 Will excess fill be removed from premises? ❑Yes o /'07 SI-a.LIoLh 6(4 O-/' 1-o 0-1' m Ce'�z-�ca(. cSd/� �G3-z�S : a /V�O PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenaVNo d restrictions with respect to this property? ❑Yes IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water iswes as prodded by Chapter 236 of the Town.Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk;County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition"as herein described.The appiFcant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary inspections.False statements made herein are Punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): dAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) COUNTY OF S being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 1 4%ay of Aa- V 5\- .201. Naft bublkf DAVID J MACKEY 1� Notary Public,State of New York Reg No 01MA63131235 PROPERTY OWNER AUTHORIZATION Qualified inl Nassau County 2026 Commission Expes (Where the applicant is not the owner) I, I residing at 5toLo O Sou rJ Aitq Ua)- ( do hereby authorize SIA Y-\2--.,`n to apply on my behalf to the Town Southold Building Department for approval as descri ed herein. 23 Owner's Signature Date Print Own is Name 2 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o ; Town Hall Annex- 54375 Main Road - PO Box 1179 C* • Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCo.southoldtownny.gov— seand(@-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: ILZ o Company Name: Electrician's Name: /L/e)j)/70 S License No.: email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: 1 -7lac 1 L — ,AjJt (l JOB SITE INFORMATION (A Information Required) Name: -Hr Address: Ue !/Cf� Cross Street: Phone No.: 1:31- 7 Bldg.Permit#: j./�j�, email: / to bn Tax Map District: 1000 C Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): f--7 4sfa.1/0,46,17 Or f' rvd/4` /770d--7-� cSc)`et .1g;*9M Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES[] NO ❑Rough In ❑ Final Do you need a Temp Certificate?: .[-1 YES❑NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# F1 New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 2 H Frame 0 Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION 's �o(--) v3d Cel, \D-5,Si H rofFOL/ �OGy BUILDING DElectrical Inspector TOWN OF SOUTHOLp N Town Hall Annex- 54375 Main Road - PO Box 1179 ^+ ' Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 r rogerr(@-southoldtownny.gov— seand(D-southoldtownnv.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8-16-23 Company Name: SUNRUN INSTALLATION Electrician's Name: SAMY MOUNAS License No.: ME-33878 Elec. email:LIPERMITS@SUNRUN.COM Elec. Phone No: 516-301-6722 ❑I request an email copy of Certificate of Compliance Elec. Address.: 177 ,CANTIAGUE ROCK ROAD, WESTBURY, NY 11590 JOB SITE INFORMATION (All Information Required) Name: JEFFREY CARLSON Address: 5660 SOUND AVE Cross Street: Phone No.: 631-276-9176 BIdg.Permit#: email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): INSTALLATION OF ROOF MOUNTED SOLAR PANELS. (12) 4.680W Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES 0 NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION fs ^g1ltFpj,�. BUILDING DEPARTMENT- Electrical Inspector rs`O�o CCG�� TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a)southoldtownny.aov- seanda-southoldtownny.Qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8-16-23 Company Name: SUNRUN INSTALLATION Electrician's Name: SAMY MOUNAS License No.: ME-33878 Elec. email:LIPERMITS@SUNRUN.COM Elec. Phone No: 516-301-6722 0 request an email copy of Certificate of Compliance Elec. Address.: 177 'CANTIAGUE ROCK ROAD, WESTBURY, NY 11590 JOB SITE INFORMATION (All Information Required) Name: JEFFREY CARLSON Address: 5660 SOUND AVE Cross Street: Phone No.: 631-276-9176 Bldg.Permit#: email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): INSTALLATION OF ROOF MOUNTED SOLAR PANELS. (12) 4.680W Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES❑] NO []Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 PhF-]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals M 1 F12 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 225 Bush Street,Suite 1400 1 c.NYS Unemployment Insurance Employer Registration Number of San Francisco,CA 94104 Insured 50-864264 Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) AMERICAN ZURICH INSURANCE COMPANY 3b.Policy Number of Entity Listed in Box"1 a" Town of Southold WC 6142876-01 Town Hall Annex Building 54375 Route 25 3c.Policy effective period P.O.Box 1179 1n/n1/?n99 to 1n/n1/gn7S Southold,NY 11971 3d.The Proprietor,Partners or Executive Officers are included.(Only check box if all partners/officers included) X❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: MarkAlbi (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 7!".�i X64 10-01-2022 (Signature) (Date) Title: VP/Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (41 S)335-6493 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov Contact Info: SUNRUN INSTALLATION SERVICE INC PAULJOYCE 177 CANTIAGUE ROCK RD WESTBURY, NY 11590 Work Description: Suffolk County Dept. of Labor. Licensing & Consumer Affairs Name Business Name n;s cetfiP,3 that thp —-e arer is du!y IlCers-d 0,e D-,u-,-%- of surfolk License Number: H-54-40 Rosalie Drago Issued 20'4 Expires. 2024 r i� - -- Suffak- CouAW nty :Dept: of La=b.or, 1L^i c*e ns�tngg & Con s u 9 } :e r Affairs a _ X' 1 MASTER ELECTRICAL LICENSE Name �^ SAMY A MOUNAS f - Business Name This. certifies that the bearer is duly licensed SUNRUN INSTALLATION SERVICES INC by the County of suffolk License Number: ME-33373 Rosalie Drago Issued A 10/01 /2003 Commissioner Expires : 10/01 /2023 SUNRINC-02 LWANG2 A�oRo CERTIFICATE OF LIABILITY INSURANCE DATE/31/2022 2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#OC36861 NAMEACT Walter.Tanner Aliiant Insurance Services,Inc. A/c°,IN Ext): (AIC,No): 560 Mission St 6th FI MAIE- L San Francisco,CA 94105 ADDREss:Walter.Tanner@alliant.com INSURERS AFFORDING COVERAGE NAIC S INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:Zurich American Insurance Company 16535 Vivint Solar Developer,LLC INSURER C:American Zurich Insurance Company 40142 c/o Sunrun,Inc. 225 Bush Street,Suite 1400 INSURERD: San Francisco,CA 94104 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER POLICY EFF POLICY EXP LTR PE OF INSURANCE INSD WVD INSPOLICY NUMBER fMMfDDNYY-n 1MMIDDNYYYI I LIMITS / A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2'000'000 CLAIMS-MADE 7 OCCUR MKLV5ENV103749 10/1/2022 10/1/2023 PREM SEs Ea oNTU Bnce $ 1'000'000 MED EXP(Any oneperson) $ 51000 PERSONAL&ADV INJURY $ 21000'000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2'000'000 X POLICY�jE�T 7 LOC PRODUCTS-COMP/OP AGG $ 2,000,000 X OTHER:Retention:$100,000 lPerProjectAgg 5,000,000 ND B AUTOMOBILE LIABILITY COa accc dentSINGLE LIMIT $ 2,000,000 X ANY AUTO BAP614287701 10/1/2022 10/1/2023 BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY Per accident $ NON-OWN PROPERTY DAMAGE AUTOS ONLY AUTOS O Y Per accid HIRED ent $ X CSm�pDod.: Ix Call.:Not Covered LiabilityDed.: $ 250,000 3UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE DED I I RETENTION$ C WORKERS COMPENSATION X STRTU E ERH AND EMPLOYERS'LIABILITY WC614287601 10/1/2022 10/1/2023 1,000,000 ANY PROPRIETO�RR/P ARTNER/EXECUTIVE YIN E.L.EACH ACCIDENT $ Mandatory in NH) CLUDED7 N/A 1,000,000 E.L.DISEASE-EA EMPLOYE $ If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below I E.L.DISEASE-POLICY LIMIT DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Workers'Compensation Policy WC6142876001 Deductible:$1,000,000. Town of Southold is included as additional insured(except workers compensation)where required by written contract. _CERTIFICATE HOLDER _ CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Building Department 53095 Route 25 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION •SYSTEM SIZE:4680W DC,380DW AC •ALL WORK SHALL COMPLY WITH 2020 NEW YORK STATE RESIDENTIAL CODE PV-1.0 COVER SHEET SE SERVICE ENTRANCE MODULES:(12)TRINA SOLAR:TSM-390DE09C.07 WITH 2018 IRCIIBCAEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: AND INSTALLATION INSTRUCTIONS. PV-2,0 SITE PLAN SE380OH-USMN MP MAIN PANEL RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 PV-4.0 ELECTRICAL EXISTING SOLAR SYSTEM INSTALLED. •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017• ��OF NE WY SP SUB-PANEL �p y � Op PV-5.0 SIGNAGE •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER SYSTEM COMPLIES WITH 690.35. k LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. z1 y y 7 2 SM SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 095450 pROFESSIONP • DEDICATED PV METER RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE 1,OR TYPE 11 Dig ita,`'I Iy Sig ned_ INV INVERTER(S) MODULES,ARE CLASS A FIRE RATED. by H U m ph rey K'' •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL AC CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ' '' AC ACDISCONNECT(S) K3rluki� ^� •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). Date; ZO23.OH. 6 OGDC DISCONNECT(S) ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 13:31:37 -04'00' •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT 1690.8(A)&690.8(B)]. ABBREVIATIONS (— INTERIOR EQUIPMENT A AMPERE L J SHOWN AS DASHED AC ALTERNATWG CURRENT AFC ARC FAULT CIR-WHTERUPTER ® CHIMNEY llrull AaM AZIVUTH coup coaposMom ATTIC VENT DC DrAECTCURRQrr FLUSH ATTIC VENT 00825-ME IE) EXISTING o PVC PIPE VENT VICINITY MAP _ _ mamAa;rE Roocaao.w�marc.Rrns�o ESS ENERGY STORAGE SYSTEM ® METAL PIPE VENT -. F•d mui�' EXT EXTERIOR . ® T V INT MERWR ENT CUSTOMER RESIDENCE: JEFFREY CARLSON MSP MAW SERNCEPANEL SATE (N) NEW flp SATELLITE DISH 5660 SOUND AVE,MATTITUCK, - NY,11952 urs NOT TO SCALE I//S FIRE SETBACKS - „n - TEL.(631)276-9176 OC CN CENTER L//I -" „-�. N PRE-FAR FRE+ASRICATEO APN:1000-121-OD-D4-OG-002-000 HARDSCAPE PROJECTNUMBER: PSF POUNDSPERSQUAREFOOT y ">asrapu.^- :pa.':.i-��': 4;rv•:¢ _... 216R-660CARL PN PHOTOVOLTAIC —PL— PROPERTY UNE " DESIGNER: (415)560.6920 cX3 RSD RAPID SHUTDOWN DEVICE O•"'"'��� SOLAR MODULES JESSICA ROSS TL TRACSFORMERLESS SCALE:NTS TYP TYPICAL , ." LL4 SHEET v vats REV NAME DATE COMMENTS COVER SHEET w VOLTS REV:Al 8/10!2023 tAN �'A sSNR MOUNT PAGE RAIT SNR MOUNT&SKIRT PV-1.0 romyoto wrsbn a.o.st SITE PLAN-SCALE=1116"=1'-0" NOTES: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. e� ARRAY DETAILS: • TOTAL ROOF SURFACE AREA:2653 SQFT. TOTAL PV• PERCENTAGE SY AREA.248.4 Q V OVERAGE: sox) (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA)'100=9.49/6 e' (E)RESIDENCE SOF NEWy ° a �'CQ•�gY KANJq QR.F AC C z Fi INV 0 (E)PV EQUIPMENT QRCFESSIONP�� g ° SE 'a LMP (E)DRIVEWAY g _ uftruln ROOFPATHWAYS (3'TYP) 00825-ME mrxvnnc:rErsoo�nao.wEZrmar.m iiwo FAX Eeos scauer y. F.Y USNdA9 CUSTOMER RESIDENCE: e� JEFFREY CARLSON 5660 SOUND AVE,MATTITUCK, (E)PV ARRAY NY,11952 e� / (N)ARRAY AR-01 TEL.(631)278-0176 � APN:1006121-00-04-00-002-000 p PROJECT NUMBER: ROOF PATHWAYS 216R-660CARL (3'TYP) (N)ARRAY AR-02 DESIGNER: (415)580-6920 cx3 JESSICA ROSS FIRE SETBACKS ARRAY TRUE MAG PV AREA SHEET (18"TYP) PITCH AZIM AZIM (SQFT) SITE PLAN (N)ARRAY AR-03 AR-01 38' 159' 171' 103.5 REV:Al 8/10!2023 AR-02 30' 69' 81' 62.1 AR-03 30° 249° 261' 82.8 PAGE PV-2.0 rc�ryrem��rb.�a.0.91 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF YP 9 YP Detail Configuration Span Spacing OC Spacing Overhang OC Spacing Overhang 9 SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1Story 2X6 RAFTERS T-3" 16° COMP,SEE DETAIL SNR-DC-00436 6-4" 2'-1" 4--0- 2-0" STAGGERED 128 MPH 3-SEG GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 1 Story 2X6 RAFTERS 10'-31. 1 fi° RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'.4- 2--l' 4'-0" 7-0" STAGGERED 5116"X5.5":2.5'MIN.EMBEDMENT DETAIL SNR-DC-00436 AR-03 COMP SHINGLE-RLU 1Story 2X6 RAFTERS 10'-7° 16' RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'.4- 2'-1' 4'-0' 2'-0- STAGGERED DETAIL SNR-DC-00436 D1-AR-01-SCALE:1/8"=1'-0" ALM:159° PITCH:38° INSTALLERS SHALL NOTIFY ENGINEER OF ANY i POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/INSTALLATION. IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12- 9,_8, �/ BOUNDARY REGION OF ANY ROOF PLANE / EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" / ` f BOUNDARY REGION ONLY AS FOLLOWS: ��OF NEW y "ALLOWABLE ATTACHMENT SPACING ��P E, KANJI, Op INDICATED ON PLANS TO BE REDUCED BY 50%. t� . 3° "ALLOWABLE OVERHANG INDICATED ON * gQ n n $ PLANS TO BE 115TH OF ALLOWABLE _ p, 3" I - 5'�'TYP ATTACHMENT SPACING INDICATED ON PLANS. m =w -'> i—23,_2" �.�. �. A 095450 ROFESSIONPV 6- D2 M:69' -SCALE:118"=1'-0" D3• :249 -SCALE:1/8"=1'-0" � �� ALM:69° ALM:249° PITCH:30° PITCH:30° in 00825-ME —7'— 1T-5" 3'-10"�— 17, �=ROCKRo D.WcsTe .WITM eKu�wssK¢scs� llvi- � FT%0li]61]d}] - / CUSTOMER RESIDENCE: 5'd"TYP - 3'17" r/ JEFFREY CARLSON , 9,-0" // 5660 SOUND AVE,MATTITUCK, / I J�11 NY,11952 TEL.(631)2765176 APN:1000.121-00-04-00-002-000 _ PROJECTNUMBER: / 5-4'TYP 216R-660CARL 6" }3'-2' 23•-2• Ti 1° DESIGNER: (415)580.6920 ex3 JESSICA ROSS '-1 SHEET LAYOUT REV:Al 8/10/2023 PAGE PV-3.0 T°"i°loaa Wxa""40.91 ---------------------------------- (22)LONGI GREEN ENERGY I TECHNOLOGY CO LTD: { 12N240 VAC I (E)125A EN-HASE 10 --l-285hf ODULES AND SINGLE PHASE AC COMBWER BOX htlCRCJNVERTEMR PAIRS _ SERVICE I WITH INTEGRATED { (E)LOCKABLE ENVOY (22)(22)ENPHASE': { METER tl: IQ6E9-2115 BLADET INE _ I M PSEGL163129319 { (E)METER AC DISCONNECT 11 'TON aox - — 240 WATT INVERTER UTILITY I E E E — E oRF-OUNnI ENT E a a a i GRID �SUPRY�JDE TAP M i { { 240V METER SOCKET 125ACONTIN000S 3R 60A,2P 12024GVAC �1 ` EXISTING EXISTING SYSTEM - ,Y-- EXISTING 200AMAN (N)LOCKABLE SOLAREDGE TECHNOLOGIES _ PANEL BLADE TYPE SE3800H-0SMN FACILITY r AC DISCONNECT 3800 WATT INVERTER JUNCTION 00X PV MODULES LOADS 3 3 2 di EouNALENf 1 TRINA SOLAR:TSMJ900E09C.07 / OF NE4y (12)MODULES 1 _ OPTIMIZERS WIRED IN: (1)SERIES OF(12)OPTIMI7.ERS (N)2. SQUARED LOAD RATED DC DISCONNECT PV BREAKER AT DU221RB WITH AFCL RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERScc OPPOSITE END 3R,30A2P COMPLIANT 5440 n W OF BUSBAR 1201240VAC NOTE TOTAL PV BACKFEED v 20A `A USED FOR INTERCONNECTION 095450 k� CALCULATIONS A �, RO SSIONP CONDUITSCHEDULE STRUCfU NLY # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 1-PVC OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHWTHWN-2 sunrun 3 1'PVC OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHNITHWN-2 E EXISTING 00825-ME - m uN1uO1re Aacx Aa1O.wFsreum,Nr Nero PNON=_msswxei vAxeaszcazorz CUSTOMER RESIDENCE: JEFFREY CARLSON 5660 SOUND AVE,MATTITUCK, NY,11952 MODULE CHARACTERISTICS TEL(631)276-9176 TRINA SOLAR:TSM-390DE09C,07: 390 W APN:1000-121-00-04-00-002-000 OPEN CIRCUIT VOLTAGE: 40.8 V PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V SHORT CIRCUIT CURRENT: 13.35 A 216R-660CARL DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 JESSICA ROSS SYSTEM SIZE: 4680 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 8/10/2023 SYSTEM OPERATING CURRENT: IZ32 A SYSTEM SHORT CIRCUIT CURRENT: 15A PAGE PV-4.0 Tempxo.asm 4.09f - INVERTER 1 LQWARNIN:G�:-' ,.QWARNIN�G! NOTES AND SPECIFICATIONS: PHOTOVOLTAIC , DISCONNECT •SIGNS AND LABELS SHALLMEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 11021(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEMIF REQUESTED BY THE LOCAL AHJ. COMBINER PANELVOLTAGE. 480 ►r SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD is ADC WORDS.COLORS AND SYMBOLS. DO NOT ADD LOADS •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAYBE ENERGIZED IN MAX RATEi i i METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC COMBINER(IF i '• ••! i! i ! IS •! INVOLVED. LABEL LOCATION: APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY PER CODE(S):NEC 2017:705.12(B)(2)(3)(c) LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),ACIDC DISCONNECT(S), INVERTER(S),DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). PER CODE(S):NEC 2017:690.53 PER CODE(S):NEC 2017:690.13(B) r 1NARNING: 0=. QY�Y,AR'N_ING'� DUAL POWER SUPPLY POWER SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: OF NEW ADJACENT TO FV BREAKER(IF UTILITY SERVICE METER AND MAIN qG YO APPLICABLE). SERVICEPANEL C �.( KANJ,1 PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(B)(3) -- 795.12(8)(2)(3)(6) E: n Lu ■ y■ ■ A 095450 7ir� 1 • Ro�ssloNP STRUCTU LY LABEL LOCATION: INSTALLED WITHIN Y OF RAPID SHUT DOWN SWITCH PER CODE(S):NEC 2017:690.56(Cx3).IFC 2012:605.11.1,IFC 2018:12.04.5.3 saltroll BUILDING SUPPLIED BY UTILITY 4" GRID AND PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED PV SYSTEM(S)ARE °°625 ME m cAv�uo:h noa noro.wesreuxr,rrr�isx ■ • 1 • ' EQUIPPED WITH RAPID -POWER SOURCE WITH RAPID SHUTDOWN SHUTDOWN DEVICE(S) CUSTOMER RESIDENCE: LABEL LOCATION: JEFFREY CARLSON INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 5660 SOUND AVE,MATTITUCK, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, NY,11952 ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. 3" TURN RAPID SHUTDOWN PER CODE(S):NEC 2017:690.31(G)(3),690.31(Gx4), IFC2012:605.11.lA SWITCH TOTHE"OFF" rruine TEL.(631)276-9176 POSMONTOSHUTDOWN APN:1000-121-0B-04-0-002.000 PV SYSTEM AND REDUCE PROJECT NUMBER: SHOCK HAZARD IN THE 216R-660CARL PHOTOVOLTAIC ADISCONNECT ARRAY. •. _ T. 16 AMPS ® DESIGNER:El (415)560-0920 eYJ NO •" • LEPV SYSTEM JESSICA ROSS DISCONNECT SHEET LABEL LOCATION: AC DISCONNECT( PHOTOVOLTAIC SYSTEM POINT OF LABEL LOCATION:ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: SIGNAGE INTERCONNECTION.N. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS POINT OF INTERCONNECTION PER CODE(S):CEC 2019:690.54.NEC 2017:690.54 ARE CONNECTED. (PER CODE NEC690.66(B),NEC705.10.225.37.2302(E)) REV:Al 8/10/2023 PER CODE(S):NEC 2017:690.56(C)(1)(a) PAGE PV-5.0 rm+ymro w�ao.e1 oad /�'MIGHTY � ENGINEERING CO. August 10,2023 RE: CERTIFICATION LETTER Project Address: CARLSON RESIDENCE 5660 SOUND AVE MATTITUCK,NY, 11952 Design Criteria: -Applicable Codes=2020 NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and 2018 NDS -Risk Category=II -Wind Speed= 128 mph,Exposure Category B,Partially/Fully Enclosed Method -Ground Snow Load=25 psf , -ROOF AR-01 :2 x 6 @ 16"OC,Roof DL=8 psf, Roof LUSL=19 psf(Non-PV),Roof LUSL=10.3 psf(PV) -ROOF AR-02&AR-03:2 x 6 @ 16"OC, Roof DL=8 psf,Roof LUSL=19 psf(Non-PV),Roof LUSL=12.9 psf(PV) To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of PV Solar System on the roof.The structural review applies to the sections of roof that is directly supporting the solar PV system. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,the PV module assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. ELECTRICAL {NSPECTION REQUIRED 'Ji CCUPAN C V. OR Sincerely, AP i.0 ED AS NOTED E°FNEy} USE I L FUS .P ��, °�. Digitally signed by 9 p * � Q Humphrey K 202308.10 ki �,NIIT O T ERTIFI AT ATF- DAM 38.p# - Date:2023.08.10 �� 12:13:42-04'00' F ® U CY FEE BY: NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED COMPLY WITH ALL CODES OF FOR POURED CONCRETE NEW YORK STATE & TOWN CODES 2. ROUGH-FRAMING& PLUMBING AS REQUIRED AND CONDITIONS OF 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE U ,--� OWN PLANNING BOARD REQUIREMENTS OFTHE CODES OF NEW -SGUTHeEDTO"USTEES YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS Y " (22)LONGI GREEN ENERGY TECHNOLOGY CO LTD. 120240 VAC (E)125 ENPHASE IO f'/l fff fff LR6-60-285M MODULES AND SINGLE PHASE AC COMBINER BOX - MICRO-INVERTER PAIRS SERVICE WITH INTEGRATED (E)LOCKABLE ENVOY (22)(22)ENPHASE: METER M: BLADE TYPE 106-60-2-US M PSEGLI 63129319 (E)METER AC DISCONNECT E)JUNCTION BOX 240 WATT INVERTER E OR EQUIVALENT E UTILITY E E E GRID ® _ SUPPLY SIOE TAP �—ro 240V METER SOCKET - 125A CONTINUOUS 3R,60A,2P ---'-' I EXISTING 200A 120240VAC �✓-`+_'4N4y^_ ....w..�--MAIN BREAKER r X'IS.'-T`IVV SYS-T-E-pV --y -p--- EXISTING �. —1-7 200A MAIN (N)LOCKABLE / SOLAREDGE TECHNOLOGIES: PANEL BLADE TYPE SE360OH-USMN FACILITY — AC DISCONNECT 3800 WATT INVERTER JUNCTION BOX PV MODULES', LOADS 3 3 2 OREqurvALENr 1 TRINASOLAR:TSM-390DE09C.07 OF NEW / (12)MODULES OPTIMIZERS WIRED IN: �'�P��y KAN,/q 'per yJ (1)SERIES OF(12)OPTIMIZERS * j 4c (N)20A SQUARE D LOAD RATED DC DISCONNECT r = °`' PV BREAKER AT DU221 R8 WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS of OPPOSITE ENO 3R,30A,2P COMPLIANT 5440 W OF BUSBAR 120/240VAG - to 095 2 NOTE:TOTAL PV BACKFEED=20A .5 450 USED FOR INTERCONNECTION p CALCULATIONS R0FESS10", STRUCTU NLY CONDUIrSCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1, NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 1"PVC OR EQU IV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 V PVC OR EQU IV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHNrrHWN-2 (1)8 AWG THHN/THWN-2 r E EXISTING 00825-ME 1r]CAN]I-E POCK ROAD,WEMURY,W 11590 PNONE 905.5105CB] FrU(9C526B.2022 CUSTOMER RESIDENCE: JEFFREY CARLSON 5660 SOUND AVE,MATTITUCK NY,11952 MODULE CHARACTERISTICS TEL.(631)276-9176 TRINA SOLAR:TSM-390DE09C.07: 390 W APN:1000-121-00 04-00-002-000 OPEN CIRCUIT VOLTAGE: 40.8 V PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V 216R-660CARL SHORT CIRCUIT CURRENT: 13.35 A DESIGNER: (415)500-6920 e JESSICA ROSS SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 4680 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 8/10/2023 SYSTEM OPERATING CURRENT: 12.32 A SYSTEM SHORT CIRCUIT CURRENT: 15A PAGE r PV-4.0 . _ / ramp/are veyoD_a. 1 i j[11 3 SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION •SYSTEM SIZE:46BOW DC,380OW AC •ALL WORK SHALL COMPLY WITH 2020 NEW YORK STATE RESIDENTIAL CODE PV-1.0 COVER SHEET SE SERVICE ENTRANCE •MODULES:(12)TRINA SOLAR:TSM-390DE09C.07 WITH 2018 IRC/IBC/IEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN ❑ C� SE380OH-USMN MAIN PANEL .RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 PV-4.0 ELECTRICAL ❑ •EXISTING SOLAR SYSTEM INSTALLED. •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. ��pF NEW Yp SCP SUB-PANEL y�P �y KAN,,y •Q PV-5.0 SIGNAGE PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC) PV LOAD CENTER MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. m i SM SUNRUN METER INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. °9sa50 �<,"� QRp ssloNP •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PN DEDICATED PV METER SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II Digitally signed ❑INV INVERTER(S) MODULES,ARE CLASS A FIRE RATED. {{•� u •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL by Humphrey K CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). Ka rl u kl OAC DISCONNECT(S) CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). Date. 2023.08.1 6 (C DC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 13:31:37 -04100I •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CE IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. ABBREVIATIONS F INTERIOR EQUIPMENT A AMPERE L J SHOWN AS DASHED AC ALTERNATING CURRENT s u n r u n AFC ARC FAULT CIRCUIT INTERUPTER ® CHIMNEY AZIM AZIMUTH COMP COMPOSITION _ G ATTIC VENT - DC DIRECT CURRENT FLUSH ATTIC VENT 00825-ME n I EXISTING O PVC PIPE VENT VICINITY MAP In-UE ROCK ROAG,WESTBURY,NY 11680 vHONE sossao s1eT EBS I ENERGY STORAGE SYSTEM ® METAL PIPE VENT EXT EXTERIOR ;;e CUSTOMER RESIDENCE: INT INTERIOR ® T-VENT JEFFREY CARLSON MSP MAIN SERVICE PANEL SATELLITE DISH 5660 SOUND AVE,MATTITUCK, - NY,11952 (N) NEW NTS NOT TO SCALE FIRE SETBACKS TEL.(631)276-9176 OC ON CENTER (� APN:1000-121-00-04-00-002-000 PREFAB PREFABRICATED r ',I "'s• - PROJECT NUMBER: �,. HARDSCAPE 216R-660CARL PSF POUNDS PER SQUARE FOOT - 's��•"•� a•^ PV PHOTOVOLTAIC —PL— PROPERTY LINE DESIGNER: (415)560-6920 ex3 RSD RAPID SHUTDOWN DEVICE SOLAR MODULES JESSICA ROSS TL TRANSFORMERLESS SCALE:NTS SHEET TYP TYPICAL REV NAME DATE COMMENTS COVER SHEET V VOLTS V w wnnS REV:Al 8/10/2023 LAN LANDSCAPE SNR MOUNT ' POR PORTRAIT SNR MOUNT&SKIRT PAGE PV-1.0 7empla(e rersbn 4.8.8 SITE PLAN-SCALE=11116" NOTES: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. e� ARRAY DETAILS: / • TOTAL ROOF SURFACE AREA:2653 SOFT.• TOTAL PV ARRAY � • PERCENTAGE PV OVESQ FT. P RAGE: SOVNO (TOTAL PV ARRAY AREAITOTAL ROOF SURFACE AREA)'100=9.4% / N. % \\ (E)RESIDENCE OF NEW y \' \ Q INV rLu \\\\ \\\ (E)PV EQUIPMENT 095450 �OROpESSloll' SE MP (E)DRIVEWAY sunrun ROOF PATHWAYS ` (3,TYP) 00825-ME 1>7 OAl GUE ROC(ROAD,MMURY.NY 11590 ..NZ- CUSTOMER HONE80551051CUSTOMER RESIDENCE: e� JEFFREY CARLSON - 5660 SOUND AVE,MATTITUCK, (E)PV ARRAY NY,11852 e� / TEL.(631)(N)ARRAY AR-01 -0 o APN:1000.121-0121-0 0-04-00-002-000 p� PROJECT NUMBER: ROOF PATHWAYS 216R-660CARL (3,TYP) DESIGNER: (415)560-6920 ex: (N)ARRAY AR-02 JESSICA ROSS FIRE SETBACKS ARRAY TRUE MAG PV AREA SHEET (18-TYP) PITCH AZIM AZIM (SQFT) SITE PLAN (N)ARRAY AR-03 AR-01 38° 159° 171° 103.5 REV:Al 8/1012023 AR-02 30' 69° 81" 62.1 PAGE PV-Z.0 AR-03 30' 249° 261° 82.8 Temple(&&&rsl&R 4.0.1 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ONWIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS T-3- 16" COMP,SEE DETAIL SNR-DC-00436 5'-4- 2--l' 4--0- 2'-0" STAGGERED 128 MPH 3-SEC GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-3" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 2'-1- 4'-0" 2'-0' STAGGERED 5/16"X5.5":2.5"MIN.EMBEDMENT DETAILSNR-DC-00436 TRACK AR-03 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-7" 16" RL UNIVERSAL,SPEEDSEAL DETAILSNR-DC-00436 COMP,SEE 5'-4" 2'-1" 4'-0" 2'.0- STAGGERED -DC-0 D1-AR-01-SCALE:118"=1'-0" AZIM:159° PITCH:38° INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED _ PRIOR TO PROCEEDING W/INSTALLATION. IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE I, EDGES(EXCEPT VALLEYS),THEN I ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" OF NEW BOUNDARY REGION ONLY AS FOLLOWS: ALLOWABLE ATTACHMENT SPACING y�QI KANj yOQ� INDICATED ON PLANS TO BE REDUCED BY 50%. * �r "ALLOWABLE OVERHANG INDICATED ON 7'I3" 13 13 13 13PLANS TO BE 1/5TH OF ALLOWABLE r x ems' 5'-4"TYP ATTACHMENT SPACING INDICATED ON PLANS. n U m a - 23'-2" 22'-4" 095450 'O �. ROFESS01 6" D2-AR-02-SCALE:118"=1'-0" D3-AR-03-SCALE:1/8"=1'-0" s u n r u n AZIM:69° AZIM:249° PITCH:30° PITCH:30° 00825-ME #-7'- 17'-5'-f3'-10"� �� KROM.WESiel1RY.NY 11590 � FAK El138flY0t1 1'8" CUSTOMER RESIDENCE: I I JEFFREY CARLSON 5'-4"TYP - T-7" 5660 SOUND AVE,MATTITUCK, I 9'-6" NY,11952 TEL.(631)276-9176 AP N:1000-121-00-04-00-002-000 8 I9" I PROJECT NUMBER: 3'-7" 5'-4"TYP - I � o � 216R-660CARL —{ 6" -{3'-2" 23'-2"-j .� DESIGNER: (415)560-6920 ex3 JESSICA ROSS SHEET LAYOUT REV:Al 8/10/2023 PAGE PV-3.0 Template Versbn_4.0.9; �l f�)125A ENPHASE IQt f� (TECHNOLOGY ENERGY GO TD: . 120/240 VACSINGLE PHASE (EAC COMBINER BOX Q f ! _�f LR6-60-285M MODULES AND MICRO-INVERTER PAIRS _ SERVICE WITH INTEGRATED (E)LOCKABLE ENVOY (22)(22)ENPHASE: METER M BLADE TYPE IQB-60-2-US ® PSEGLI 63129319 (E)METER AC DISCONNECT (E)JUNCTION Box 240 WATT INVERTER UTILITY E E — E OR EQUIVALENT E E �` �` �' GRID ® (! SUPPLY BODE TAP �O _ 240V METER SOCKET 125A CONTINUOUS 3R,60Al2P (I EXISTING 200A 120240VAC MAIN BREAKER EXISTING SYSTEM ) .�— EXISTING 200A MAIN (N)LOCKABLE SOLAREDGE TECHNOLOGIES: 1-17 PANEL BLADE TYPE SE380OH-USMN FACILITY AC DISCONNECT 3800 WATT INVERTER JUNCTION BOX PV MODULES LOADS 3 3 s 2 ORECUNALENj 1 (72)MO ULESINA SOLAR:TSM-390DE09C.07 yCQ��pFNEW Knryq YO/p o�o _ OPTIMIZERS WIRED IN: `Y (1)SERIES OF(12)OPTIMIZERS (N)20A SQUARE D LOAD RATED DC DISCONNECT PVBREAKERAT 0U221 RB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS r = s� w OPPOSITE ND 3R,30A.2P 1 0240VAC COMPLIANT 544 OF BUSBAR NOTE:TOTAL PV BACKFEED=20A USED FOR INTERCONNECTION A 095450 CALCULATIONS RpSS(pNP�' STRUCT NLY CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 1"PVC OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHNffHWN-2 s u n r u n 3 1"PVC OR EQU IV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 E EXISTING 00825-ME 1Ti CAMIAGUE ROLX ROM.WE3fBURY,NY 11580 PHONE B..M.— FA%Bf536830Yt CUSTOMER RESIDENCE: JEFFREY CARLSON 5660 SOUND AVE,MATTITUCK, NY,11952 MODULE CHARACTERISTICS TEL.(631)276-9176 TRINA SOLAR:TSM-390DE09C.07: 390 W APN:1000-121-00-04-00-002.000 OPEN CIRCUIT VOLTAGE: 40.8 V PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V 216R-660CARL SHORT CIRCUIT CURRENT: 13.35 A DESIGNER: (415)580-0920 exf JESSICA ROSS SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 4680 W _ SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 8/10/2023 SYSTEM OPERATING CURRENT: 12.32 A SYSTEM SHORT CIRCUIT CURRENT: 15A PAGE PV-4.0 T mpela_—JorL.4.0A /!► INVERTER 1 NOTES AND SPECIFICATIONS: rQWAt N I N G 1FQWARN INV I r- •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE DISCONNECTPHOTOVOLTAIC DC 110.21(6),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL MAXIMUM SYSTEM VOLTAGE480 • •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD DO NOT ADD LOADS 15ADC WORDS,COLORS AND SYMBOLS.LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN MAX RATED OUTPUTOFTHE CHARGEMETHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC'COMBINER(IF • •• ••• • • • 15 • INVOLVED. APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4.2011,PRODUCT SAFETY LABEL LOCATION: PER CODE(S):NEC 2017:705.12(B)(2)(3)(c) LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),AC/DC DISCONNECT(S), AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2017:690.13(B) PER CODE(S):NEC 2017:690.53 �QWARN�ING - QWARNING DUAL POWER SUPPLY POWERSOURCEOUiPUrCONNECTION SOURCES:UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: OF NEW ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN �� r0 APPLICABLE). SERVICE PANEL. y'�P E� KANiq 'P PER CODE(S):NEC 2017: PER COOE(S):NEC 2017:705.12(B)(3) Q• sv^- T 705.12(13)(2)(3)(b) 095450 0R p FOR SOLAR PV SYSTEM OFESSION STRUCTU NLY LABEL LOCATION: INSTALLED WITHIN T OF RAPID SHUT DOWN SWITCH PER CODE(S):NEC 2017:690.56(C)(3),IFC s u n r u n 2012:605.11.1,IFC 2018:1204.5.3 BUILDING SUPPLIED BY UTILITY 4" GRID AND PHOTOVOLTAIC - - SYSTEM 00825-ME SOLAR PV SYSTEM EU'IPPED: PV SYSTEM(S)ARE • • • ' EQUIPPED WITH RAPID U CID In—•'°;° Ro�. �.,NY"sem WITH. RAPID SHUTDOWN . ■• • • SHUTDOWN DEVICE(S) CUSTOMER RESIDENCE: LABEL LOCATION: JEFFREY CARLSON INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 5660 SOUND AVE,MATTITUCK, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, NY,11952 ON EVERY JBIPULL BOX CONTAINING DC C;RCUITS. 3° TURN RAPID SHUTDOWN PER CODE(S):NEC 2017:690.31(G)(3),690.31(G)(4), IFC 2012:605.11.1.4 SWITCH TO THE"OFF' •wp —— e TEL.(631)276-9176 POSITION TO SHUT DOWN (r� APN:1000-121-0D-04-00-002-ODD PV SYSTEM AND REDUCE LI� PROJECT NUMBER: SHOCK HAZARD IN THE 216R-660CARL PHOTOVOLTAIC ADISCONNECT ARRAY.MAXIMUM AG LE EE e •. DESIGNER: (415)580-6920 ex3 NOMINAL•• • 1 PV SYSTEM JESSICA ROSS DISCONNECT SHEET LABEL LOCATION: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF LAON BEL EL LOCATION: CATION:MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS POINT OF INTERCONNECTION PER CODE(S):CEC 2019:690.54,NEC 2017:690.54 ARE CONNECTED. (PER CODE:NEC690.56(B),NEC705.10,225.37.230.2(E)) - REV:Al 8/10/2023 PER CODE(S):NEC 2017:690.56(C)(1)(a) PAGE PV-5.0 7 mprae•versbn_a.a.9 Mono Multi Solutions NOertex S PRODUCT:TSM-DE09C.07 BACKSHEET MONOCRYSTALLINE MODULE PRODUCT RANGE:380-405W 405W 0 "45W Z1 . 1% MAXIMUM POWER OUTPUT POSITIVE POWER TOLERANCE MAXIMUM EFFICIENCY ..� High value •More productivity from same roof size. •Outstanding visual appearance. •Leading 210mm cell technology. Small in size,big on power s •Small format module allow greater energy generation in limited space. •Up to 405W,21.1%module efficiency with high density interconnect technology. •Multi-busbar technology for better light trapping effect,lower series resistance and improved current. •Reduce installation costwith higher power bin and efficiency. P •Boost performance in warm weatherwith lower temperature coefficient • (-0.34%)and operating temperature. s @�o Universal solution for residential and C&I rooftops •Designed for compatibility with existing mainstream optimizers,inverters 0 r and mounting systems. •Perfect size and low weight makes handling and transportation easier and more cost-effective. •Diverse installation solutions forflexibility in system deployment High Reliability e •25year product warranty. •25 year performance warranty with lowest degradation. •Minimized micro-cracks with innovative non-destructive cutting r; . • technology. 0 � � •Ensured PID resistance through cell process and module material • control. • ® • •Mechanical performance up to+6000 Pa and-4000 Pa negative load • Trina Solar's Backsheet Performance Warranty • • 100% 9B.0% ■ Trina standard 3 $ 90g'a a 84.8% u' Years 5 10 15 20 25 1 Comprehensive Products arid System Certificates to IEC61215/IEC61730/IEC61701/IEC62716/UL61730 !s! °Om 1509001:Quality Management5ysfem Trin- asolar !s! ISo14001:EnvironmentalManagementSystem C e iA� ,or, 15014064:Greenhouse Gases Emissions Verification . C �i . 15045001:Occupatlonal Health and Safety Management System VertexSBACKSHEET MONOCRYSTALLINEMODULE DIMENSIONS OF PV MODULE(mm) 1096 30 1096 1048 I-V CURVES OF PV MODULE(400W) 14.0 12.0 10f)OIN/ma n.o 4-09.14 10.0 Installing Hale 90 800W/ma Q 8.0 JA w 7.0 600W/me 6.0 U 5.0 4.0 400W/m' .a 0 0 3.0 0 2.0 200W/ma -� 1.0 8-04.3 Grounding Hole 0 SD 20 30 40 50 Voltage(V) P-V CURVES OF PV MODULE(40OW) 8-Draln Hale 450 1000W/m° 400 to Front View Back View 350 Boow/ma 11.5 Silicon Sealant 115 Sllicon Sealant 300 Laminate Laminate 3 250 600W/mr u 200 0 400W/m' Q. 150 0 0 100 200W/ma Frame Frame \ 50 0 10 20 30 40 50 33 15.4 Voltage(V) A-A B-B ELECTRICAL DATA(STC) MECHANICAL DATA Peak Power Watts-PM (Wp)• 380 3B5 390 395 400 405 Solar Cells Monacrystalline No.of cells 120 cells PowerTolerance-"(W) 0-15 Module Dimensions 1754.1096.30 mm(69.06x43.15xL1B inches) Maximum Power Voltage-VHpP M 33.4 33.6 33.8 34.0 34.2 34.4 Weight 21.0 kg(46.3 lb) Maximum Power Current-Imm(A) 11.38 11.46 11.54 11.62 11.70 11.77 Glass 3.2mm(0.13Inches),HlghrammlsslomARcnated Heatsorngth-d Class Open Circuit Vohage-Voc(V) 40.4 40.6 40.8 41.0 41.2 41.4 Encapsulant material EVA/POE Short Orcult Current-Isc(A) 12.00 12.07 12.14 12.21 12.28 12.34 Backsheet Transparent backsheet Module Efficiency n m(%) 19.8 20.0 20.3 20.5 20.8 21.1 Frame 30mm(S.16 inches)Anodized Aluminium Alloy MirtmarrPtooaw/m2.eentempeafua2s•eAI M-AMLs.•Measosle9to1e--.3W J-Box IP 68 rated Electrical characteristics with different power bin(reference to 10%Irradiance ratio) Cables Photovoltaic Technology Cable 4.0mmz(0.0061nchesa), Portrait:350/280 mm(13.78/11.02 Inches) Total Equivalent power-PMnx(Wp) 407 412 417 423 428 433 Landscape:N 1100 mm/P 1100 min(43.31/43.31 inches) Maximum Power Voltage-VMPPM 33.4 33.6 33.8 34.0 34.2 34.4 Connector MC4EV02/TS4• Maximum Power Current-IMPP(A) 12.19 12.26 12.34 12.44 1251 12.59 •Please rete,to mgl,rdl ooheetfor spedfled corm- Open Circuit Voltage-VCM 40.4 40.6 40.8 41.0 41.2 41.4 TEMPERATURE RATINGS MAXIMUMRATINGS Short Orcuh Cufrent-isc(A) 12.92 13.00 13.08 13.20 13.25 13.36 NOCf(tioo wac erawgcenTemperama) 43°C(±2°C) Operational Temperature -40-+85°C Irradiance ratio(rear/front) 10% Temperature Coefficient of PHAx -0.34%/°C Maxi mum System Voltage 1500V DC(IEC) PoweralfsdaMy.70s51A. Temperature Coefficient of Voc -O.ZS%/°C 150OVDC(UL) ELECTRICAL DATA(NOCT) Temperature Coefficient oflsc 0.04%/9C Max Series Fuse Rating 25A Maximum Power-PMAx(Wp) 286 290 294 29B 302 305 WARRANTY PACKAGING CONFIGUREATION Maximum Power Voltage-VMPPM 31.4 31.6 31.8 31.9 32.1 32.4 25 year Product Workmanship Warranty Modules per box:36 pieces Maximum Power Current-IMPP(A) 9.12 9.18 9.24 9.32 -9.38 9.42 25 year Power Warranty Modules per 40'container.828 pieces Open Circuit Voltage-VocM 38.0 38.2 38.4 30.6 3B.B 38.9 2%first year degradation Short Circuit Current-Isc(A) 9.67 9.73 9.78 9.84 9.90 9.94 0.55%Annual Power Attenuation No -.had:Onceat.00wmr.Amb1mtTc,Wo.00.2Mwua spaedte✓: (Nease,oferteproeuct-tyfordetnns) • ' C CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USINGTHE PRODUCT. Trinasolar 020RTrinaSolarCo..,Ltd.All rights reserved:Specifications Included inthisdatasheetare subject tocharigewithoutnotice. Version number:TSM_NA 2022 A solar=@ " • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE330OH-US/SE5000H-US/ SE6000H-US/ SE7600H-US/SE10000H-US/SE1140OH-US solar---- •*0 • a a optirnlzed.installation with HD-lave technology - Specifically designed to work with power optimizers Record-breaking efficiency . Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 20.14,and 2017,per article 690.11 and 690.12 UL1741 SA certified,.for CPUC Rule 21 grid compliance Extremely small ® High reliability without any electrolytic capacitors 1 W Built-in module-level monitoring r. �sl�lI/ — Outdoor and indoor installation . ave Optional:Revenue grade data;ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us =@ " Single Phase Inverter solar with HD-Wave Technologyfor North America SE3000H-US/ SE380OH-US/SE5000H-US/ SE600OH-US/ SE760OH-US/ SE10000H-US/SE1140OH-US SE3000H,U5 j SE3800H US SESOOOH US ; SE6000H US . SE7600H-USSE10000HuU5 SE11400H US! — __ __@ __ ___ _ 3800 @ 240V'— 16000 240V�' Rated AC Power Output 3000 5000 7600 10000 11400 VA 3800 @ 240V i Max.AC Power Output 6000 @ 240V gutput 3000 3300_ 208V i 5000 5000 @.240V. 7600 I 10000 11400 j VA AC Out ut Volta a Min.Nom:Max. ✓ Vac (183. 208 229) i .. ....... _. i. AC Output Voltage Min.-Nom.-Max. Vac AC Fre u.en (Nomiin..a.l1..., 9060533 . ... .. , Hz a. Maximum Continuous Output Current 16 24 A 208V Maximum Continuous Output Current i12.516 21 25 32 42 47.5 A GFDI Threshold 1 A ... .. Utility Monitoring,Islanding Protection, Yes Count Confi urableThresholds INPUT Maximum DC Power @240V 4650 590D 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 7750 ...... ..... ........ ... . Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Volta a 380 400 Vdc Maximum Input Current 208V 9 13.5 . Maximum Input Current @240V8;5 10,5 13.5 16,5 20 27 30.5 Adc .. Max.Input Short Circuit Current 45 Adc d Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter EfFicienc 99 99.2 .......................Y...... i. . o . CEC Weighted Efficiency....... ......... 99..... g Ni httime Pawer Conm� sution <2.5 W --------- --- -- ADDITIONAL FEATURES Su orted Communication Interfaces i R_5 _485,Ethernet,Zi Bee o tional,Cellular o tional Revenue Grade,Data,,ANSI 012.20 .•• ,, ,_. Otional Rapid Shutdown-NEC 2014 and 2017 ----- -- __—T �u Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 �----------_.__---__—_._.�.—___.--------__.___------ STANDARD COMPLIANCE Safety UL1741,UL1741 5A,UL16999,CSA 022.2,Canadian AFCaccording to T.I:L.M-07 Grid Connection Standards j IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size AWG Range 3 4"minimum/14-6 AWG 3/4"minimum 14-4 AWG / .... .......... ............................... ........ ........ ..i......... ...... ..�............ DC Input Conduit Size/#of Strings/ j 3/4"minimum/1-3 strings/ 3/4"minimum/1-2 strings/14-6 AWG .AWG Rang?......................... ....l...... ....... ............,.. ........................... .. . .. ...... ..,. 14.-6 AWG ... ...... ;.. 21.3 x 14.6 x 7.3/540 x 370 Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 x 185 j in/mm ... Weight with Safety Switch......... .... I......... 22/.10. ...........i..25.1/11.4..i...... ..26,2/'11.9... ,....,.�.......`50 38.8/17.6.. ...... i..l dBAg Noise <25 ..........I...I—................... ........._............................................ ................. ..... .............-..... ..........._.... .. Coolin Natural Convection I NaturaIcon vection I g................................... ........I.............................I . ............... . Operating Temperature Range 13 to =25 to+6013)(-40°F/-40°C option)1a1 i °F. °C Protection Rating. ... ................... .• NEMA 311(Inverter with Safety Switch) 1�1 For other regional settings please contact SolarEdge support 1z1 Revenue grade inverter P/N:5Epoo1H-US000NNC2 131 For power de-rating Information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf 141-40 version P/N:SE)o=H-US000NNU4 nm RoHS O So larEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SO1 respectiveare trademarks or registered trademarks 41. -4 •° / /Technologies, • } -• - /moi /'�' —i/ '"` A— ry4 J ' :''. ?. ,'rya. t. Y s r+�^ • - _ 1 '"^. • _ moi. M-. C S .• - _> MV :Y. .,sd. 77�� �'T:����Ki. }"-z.;J1'ti9N�+.srir...,.i,`�c= ���w.x ?t:w��r.�1r9�t"..'+�r ;:i�.' .&f.e. ,+:.[5e.. �'a .& _ .-..5�'.;i�-_�•� �r .,*�-:+"b,.,..a..a,s..� 'r ® System designed with All parts fit in a box for easy maximum versatility for any logistics ® arrays including staggered Drop-in features make the install process intuitive and fast ®�®® Simple design allows system to ®® be installed by single installer UListed to UL Standard 2703 for �® on the roof L Grounding/Bonding and Fire Classification SnapNrack RL Universal highestis ,designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm: and the • of Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of North-South adjustability for all Mounts Mounts • Single mount used at all locations on array • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments ;: Links • Simple design provides mounting platform between two to four modules • Clamps onto top of modules securing them in place while providing row-to-row bonding :or Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules • Skirt length is compatible with both portrait and landscape module orientations Quality. Innovative . Superior. SnapNrack Solar • e Solutions are engineered to optimize material use and labor resources • improve overall installationquality and • O2019 by -• Solar • • Solutions.All rightsreserved DESCRIPTION: DRAWN BY: SNAPNRACK RL UNIVERSAL, MOUNT mwatkins 5flarack REVISION: PART NUMBER(S): 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 84105 LISA PHONE(415)580-6900•FAX(415)SBD-8902 242-02155 THE WFORMATION IN THIS ORAWING IS WNIRDENTULL AND PROPRIETARY.ANY REPROOUOTION,DISCLOSURE,OR USE THEREOF IS PROHIBITED W1THOUTTHE WRRTEN CONSENT OF SUNRUN SO"LLG 10 5 0 0 i 4 3 7 8 1 2 o 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X IIN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 ) DESCRIPTION: DRAWN BY: APNRACK RL UNIVERSAL, MOUNT mwatkins snarack SN . REVISION: PART NUMBER(S): 595 MARKET STREET,29TH FLOOR.SAN FRANCISCO,CA 94105 USA PHONE(415)5BM900•FAX(415)580-6902 242-02155 THE INFORMATION IN TNIS DRAWING IS WNFIDENRILL AND PROPRIETARY.ANY REPRODUCTION,OISCIOSURE,OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH U.0. —1.50 3.41 1.50 FS' 2.35 1.50 1.55 .66 2.00 1.24 1.00 SLOT sy 2.63 ALL DIMENSIONS IN INCHES YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 225 Bush Street,Suite 1400 1c.NYS Unemployment Insurance Employer Registration Number of San Francisco,CA 94104 Insured 50-864264 Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) AMERICAN ZURICH INSURANCE COMPANY 3b.Policy Number of Entity Listed in Box"1 a" Town of Southold WC 6142876-01 Town Hall Annex Building 54375 Route 25 3c.Policy effective period P.O.Box 1179 Southold,NY 11971 1n/n1/9ri99 to 1ft/n1lgft�3 3d.The Proprietor,Partners or Executive Officers are included.(only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Mark Alb! (Print �name �of authorized representative or licensed agent of insurance carrier) Approved by: �4'a�.�'4 6, 10-01-2022 (Signature) (Date) Title: VP/Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (415)335-6493 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov Contact Info: SUNRUN INSTALLATION SERVICE INC PAULJOYCE 177 CANTIAGUE ROCK RLQ WESTBURY, NY 11590 Work Description: Suffolk County Dept. of Labor. Licensing & Consumer Affairs :�- i a _ F-:Ql,r,:: ;l.t�[1Q�l�?l•F*.7 LIC.F�JSE . Name JC-"CE Business Name '1.S Cwlifies that the ;e2rer is duiV IiC?n5ed �:.r:ur. .nt-aliaiton r n,,nn �•- Lt�e Ci:urr+r of Suffolk License Number: H-54"40 Rosalie Drago Issued: 4 Comm.ssioner Expires: 09!01,2024 f WN M9.0 rZ73, Suffo�:k C=oumy Dept. of- o= , Lrcen-s=i ng & Co-n=s.u,,m.er- Af.,arrs i MASTER ELECTRICAL LICENSE Name z SAMY A MOUNAS Business Name Thi=s certifies that the bearer is duly licensed SUNRUN INSTALLATION SERVICES INC by the County of suffolk License Number: ME-33878 Rosalie Drago Issued : 10/01 /2003 Commissioner Expires : 10/01 /2023 - - - -- ----— Suffolk County Dept. of Labor, Licensing & Consumer Affairs I MASTER ELECTRICAL LICENSE Name SAMY MOUNAS Business Name "•.. . . SUNRUN INSTALLATION SERVICES INC. This certiries that the bearer is duly licensed 33878 . by the County of Suffolk License Number !n2 03 Issued: Drag' Expires: 10101/2025 Commissioner SUNRINC-02 LWANG2 ACOROp CERTIFICATE OF LIABILITY INSURANCE FDATE(MM/DD/YYMn 8/31/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER License#OC36861 COMEACT Walter,Tanner Alliant Insurance Services,Inc. PHONE FAX 560 Mission St 6th FI AIC,No,Ext): Arc,No): San Francisco,CA 94105 Ao RIESs ,Walter.Tanner@alliant.com INSURERS AFFORDING COVERAGE NAIC# INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:Zurich American Insurance Company 16535 Vivint Solar Developer,LLC INSURER C:American Zurich Insurance Company 40142 c/o Sunrun,Inc. 225 Bush Street,Suite 1400 INSURERD: San Francisco,CA 94104 INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTRTYPE OF INSURANCE ADSDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2'000'000 CLAIMS-MADE a OCCUR MKLV5ENV103749 10/1/2022 10/1/2023 DAMAGETORENTED 1,000,000 EM SES Ea occurrence $ MED EXP(Any oneperson) 5,000 PERSONAL&ADV INJURY $ 2'000'000 TX N'LAGGREGATELIMITAPPLIESPER: GENERAL AGGREGATE 2,000,000 POLICY[X]JECT 7 LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER:Retention:$100,000 Per Project Agg 5,000,000 B AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 2,000,000 Ea accident $ X ANY AUTO BAP614287701 10/1/2022 10/1/2023 BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY Per accident $ HIRED NON-OVED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY Per accident $ X CSrwgpDed.: X Coll.:Not Covered LiabilityDed.: 250,000 UMBRELLALWB HOCCUR EACH OCCURRENCE EXCESS LIAB CLAIMS-MADE AGGREGATE DED RETENTION$ C WORKERS COMPENSATION AND EMPLOYERS'LIABILITY X STATUTE ERH YIN WC614287601 10/1/2022 10/1/2023 1,000,000 ANY PROPRIETORIPARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? �N N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ 1,000,000 If yes,describe under 11000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLESACORD 101,Additional Remarks Schedule,maybe attached If more space Is required) Workers'Compensation Policy WC6142876001 Deductible:$1,000,000. Town of Southold is included as additional insured(except workers compensation)where required by written contract. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Route 25 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD W FAMIGHTY ENGINEERING CO. August 10,2023 RE: CERTIFICATION LETTER Project Address: CARLSON RESIDENCE 5660 SOUND AVE MATTITUCK,NY, 11952 Design Criteria: -Applicable Codes=2020 NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and 2018 NDS -Risk Category=II -Wind Speed=128 mph,Exposure Category B,Partially/Fully Enclosed Method -Ground Snow Load=25 psf -ROOF AR-01 :2 x 6 @ 16"OC,Roof DL=8 psf,Roof LUSL=19 psf(Non-PV),Roof LUSL=10.3 psf(PV) -ROOF AR-02&AR-03:2 x 6 @ 16"OC,Roof DL=8 psf,Roof LUSL=19 psf(Non-PV),Roof LUSL=12.9 psf(PV) To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of PV Solar System on the roof.The structural review applies to the sections of roof that is directly supporting the solar PV system. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,the PV module assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. ELECTRICAL INSPECTION REQUIRED Sincerely, OCCUPANCY OR MAIOD AS NOTED t0°FNE{yUSEISUNLAWFUL g�P PE „ ° Digitally signed by ? HumphreyKKariukiWITHOUT CERTIFICAT DATB.P.# oC Date:2023.08.10 IES%%% = 12:13:42-04'00' OF OCCUPANCY FEss�FEEBY: NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED COMPLY WITH ALL CODES OF FOR POURED CONCRETE NEW YORK STATE & TOWN CODES 2. ROUGH-FRAMING&PLUMBING AS REQUIRED AND CONDITIONS OF 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. � ;�_ OW,N PLANNINGBOARD ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW 4GUTHeLDMWMSTEES YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS YNR N iglrtv Engineering Co 1 1703 Rd Charlotte,PJC_28211 1 (930)510.9776 1 info@inigt tyengineeriagco.corn Pg 1 of 8 SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION SYSTEM SIZE:468OW DC,380OW AC ALL WORK SHALL COMPLY WITH 2020 NEW YORK STATE RESIDENTIAL CODE PV-1.0 COVER SHEET SE SERVICE ENTRANCE .MODULES:(12)TRINA SOLAR:TSM-390DE09C.07 WITH 2018 IRC/IBC/IEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN SE380OH-USMN MP MAIN PANEL .RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 PV-4.0 ELECTRICAL •EXISTING SOLAR SYSTEM INSTALLED. •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. ,�OF NEW YO SP SUB-PANEL yqP �q KAIVj "P PV-5.0 SIGNAGE •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY Qty t GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. * � LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. m U SM SUNRUN METER0 •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741, 09 Sri FESS{O�P •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II Digitally signed INV INVERTER(S) MODULES,ARE CLASS A FIRE RATED. •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL by Humphrey K AC AC DISCONNECT(S) CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). Ka rI u ICI O - p •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(6). Date 2023.OH. 6 DCDC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 1 ate:2 7 3.08.1 041001 13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX 20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. ABBREVIATIONS F___1 INTERIOR EQUIPMENT A AMPERE L J SHOWN AS DASHED AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER ® CHIMNEY s unrun AZIM AZIMUTH COMP COMPOSITION Q ATTIC VENT DO DIRECT CURRENT 0 FLUSH ATTIC VENT 00825-ME (E) EXISTING G PVC PIPE VENT VICINITY MAP 1Tl CANMGOE ROCK ROAD.WESTBDRY,NY 11590 ESS ENERGY STORAGE SYSTEM ® METAL PIPE VENT FA%815 - EXT EXTERIOR ® T-VENT �'�''=0 CUSTOMER RESIDENCE: INT INTERIOR JEFFREY CARLSON MSP MAIN SERVICE PANEL 1P SATELLITE DISH 5660 SOUND AVE,MATTITUCK, (N) NEW NY,11952 NTS NOTTO SCALE FIRE SETBACKS .,,�'" TEL.(631)276-9176 OC ON CENTER ® APN:1000-121-00-04-00-002-000 PRE-FAB PRE-FABRICATED F11-11171 HARDSCAPE ,. PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT - - aW"'• " _ '. ♦ .Q 216R-660CARL PV PHOTOVOLTAIC -PL- PROPERTY LINE , „„• DESIGNER: (415)580-6920 Bx3 RSD RAPID SHUTDOWN DEVICE SOLAR MODULES JESSICA ROSS TL TRANSFORMERLESS SCALE:NTS ”, SHEET TYP TYPICAL REV NAME DATE COMMENTS COVER SHEET V VOLTS W WATTS REV:Al 8/10/2023 LAN LANDSCAPE SNR MOUNT PAGE FOR PORTRAIT SNR MOUNT&SKIRT PV-1.0 Temdefe versbn_�.0.5f SITE PLAN-SCALE=1116"=1'-011 NOTES: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. P� ARRAY DETAILS: / • TOTAL ROOF SURFACE AREA:2653 SOFT. •• TOTAL P SQ FT PERCENTAGEARRAY COVERAGE: SpVNO PSE P� (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE / AREA) 100=9.4% P� (E)RESIDENCE NEbyY BEY KANiq pQ� r A O INV mLIU <° (E)PV EQUIPMENT AR 095450 .� ,: OFESSION f n SE LMP (E)DRIVEWAY sunrun ROOF PATHWAYS (3-TYP) 00825-ME 1)l CANR UER00%R ,NE81 my,w11690 PHONE 805.510.618! q FPx 00.9368RBT2 f CUSTOMER RESIDENCE: P� JEFFREY CARLSON 5660 SOUND AVE,MATfITUCK, (E)PV ARRAY NY,11952 (N)ARRAY AR-01 TEL.(631)276.9176 ,g APN:1000-121-00-04-00-002-000 P� PROJECT NUMBER: ROOF PATHWAYS 216R-660CARL (3'TYP) P� DESIGNER: (415)580-6920 ex3 (N)ARRAY AR-02 JESSICA ROSS FIRE SETBACKS ARRAY TRUE MAG PV AREA SHEET (18-TYP) PITCH AZIM AZIM (SQFT) SITE PLAN (N)ARRAY AR-03 AR-01 38° 159° 171° 103.5 REV:Al 8/10/2023 AR-02 30° 69° 81° 62.1 AR-03 30° 249° 261° 82.8 PAGE PV-2.0 T—pble-.WL4.0.91 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN-CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF e Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON —WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 7'-3" 16" COMP,SEE DETAIL SNR-DC-00436 6'-4" 2--l' 4'-0" 2'-0' STAGGERED 128 MPH 3-SEC GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-3" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 6'-4" 2--l' 4'-0' 2'-0' STAGGERED 5/16"X5.5":2.5"MIN.EMBEDMENT DETAIL SNR-DC-00436 AR-03 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-7" 16" RL UNIVERSAL,SPEEDSEALTRACK ON COMP,SEE V-4" 2'-1- 4'-0" 2'-0" STAGGERED DETAILSNR-DC-00436 D1-AR-01-SCALE:1/8"=1'-0" AZIM:159° PITCH:38° INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W1 INSTALLATION. °IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" 9 8" BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ��OF NEI.y Y "ALLOWABLE ATTACHMENT SPACING �CQ E.( KAN,1q 0 INDICATED ON PLANS TO BE REDUCED BY 50%. 7'-3" "ALLOWABLE OVERHANG INDICATED ON * _% PLANS TO BE 1/5TH OF ALLOWABLE x s°i of -1 5'-0"TYP ATTACHMENT SPACING INDICATED ON PLANS. o w 3" Ef ? - 23'-2" 22'-4° 095450 A �.� ROFESSIONP 6" D2- * -SCALE:118"=1'-0" D3- •SCALE:118"=1'-0" s u n r u n AZIM:69 69° AZIM:249 249° PITCH:30° PITCH:30° 00825-ME —7'— 17'-5" 3'-1Dn�- 1R CANiIAGOE ROCX ROAD.NE9IBURY,NY 11590 PHONE 9055i0.91HI � -,— FA%00.5268.Y0�3 1'8" CUSTOMER RESIDENCE: I JEFFREY CARLSON 5'-4"TYP - 3'-7" 5660 SOUND AVE,MATTITUCK, I 9'-6" NY,11952 TEL.(631)276-9176 81_gn R P R R APN:1000-121-00-04-00-002-000 _ PROJECT NUMBER: 3-7" 5 4"TYP 216R-660CARL I --,- 6" _{3'-2" 23,_2" DESIGNER: (415)560-6920 ex3 JESSICA ROSS SHEET LAYOUT REV:Al 8/10/2023 PAGE PV-3.0 T­#.f. 21 LONI GREEN EN fl !� fffTEC NOGOGY CO LTDERGY - 120240 VAC (E)125A ENPHASE IQ (� '� (�f ♦� LR6-6o-265M MODULES AND SINGLEPHASE AC COMBINER BOX `Y `Y MICRO-INVERTERPAIRS _ SERVICE WITH INTEGRATED (E)LOCKABLE ENVOY (22)(22)ENPHASE: METERMO BLADE TYPE IQ6-60-2-US 'PSEGLI 63129319 (E)METER AC DISCONNECT (E)JUNCTION eQx 240 WATT INVERTER UTILITY E E — E oR EQUIVALENT GRID SUPPLY 50]ETAP �o Ij ' I 240V METER SOCKET ' 125A CONTINUOUS 3R,60A,2P i I EXISTING 200A 120240VAC MAIN BREAKER I _ EXISTING SYSTEM EXISTING 200A MAIN (N)LOCKA13LE SOLAREDGE TECHNOLOGIES: PANEL BLADE TYPE SE380OH-USMN FACILITY AC DISCONNECT 3600 WATT INVERTER JUNCTION BOX PV MODULES LOADS 3 3 2 QREOUNALENi 1 TRINASOLAR:TSM-390DE09C.07 OF NEW . ,, (12)MODULES ��P��,( KAluq yp.Q _ —� _ OPTIMIZERS WIRED IN: (1)SERIES OF(12)OPTIMIZERS Q.t•� t„� (N)20A` SQUARED LOADRATED DC DISCONNECT * 1 PVBREAKERAT DU221RB WITH AFCI,RAPITD D SHUOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,30A.2P COMPLIANT S440 P OF BUSBAR 120240VAC NOTE:TOTAL PV BACKFEED=20A USED FOR INTERCONNECTION 00—095450 <( CALCULATIONS - FESSI014 STRUc NLY CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 1”PVC OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 S u n r u n 3 1"PVC OR EQUIV. (2)10 AWG THHNfTHWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHNrrHWN-2 E EXISTING 00825-ME 1T1C GUE R=ROM,W BIBURY.W 11500 PHGNE 005.500.5181 F1X00525020P2 CUSTOMER RESIDENCE: JEFFREY CARLSON 5660 SOUND AVE,MATTITUCK, NY,11952 MODULE CHARACTERISTICS TEL-(631)276-9176 TRINA SOLAR:TSM390DE09C.07: 390 W APN:1000-121-00-04-00-002-000 OPEN CIRCUIT VOLTAGE: 40.8 V PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V 216R 660CARL SHORT CIRCUIT CURRENT: 13.35 A DESIGNER: (415)580.6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 JESSICA ROSS SYSTEM SIZE: 4680 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 8/10/2023 SYSTEM OPERATING CURRENT: 12.32 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE Pv-4.� romWale re�4.B.e+ NO] /!� INVERTER 1 NOTES AND SPECIFICATIONS: _ rQWARN ING rQ�. WARNIII�<7REMENTS OF THE NEC 2017 TCLE PHOTOVOLTAIC • • •110.21(B),UNIGNS AND LESS SPECIFIC INSTRUCTIONSELS SFZL—MEET THE IAARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL MAXIMUM SYSTEM VOLTAGE: 480 • •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD DO NOT ADD LOADS 15 '• •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN MAX RATED OUTPUT CURRENT OF METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC COMBINER(IF CONTROLLER••DC-TO-DC C• • 15 ADC INVOLVED. APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LABEL LOCATION: PER CODE(S):NEC 2017:705.12(B)(2)(3)(0) LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),AC/DC DISCONNECT(S), INVERTER(S),DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). PER CODE(S):NEC 2017:690.13(B) PER CODE(S):NEC 2017:690.53 �Q�. WARNING �Q[ WARNING DUAL POWER SUPPLY POWER SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: ADJACENTTO PV BREAKER(IF UTILITY SERVICE METER AND MAIN 4�OF EvV APPLICABLE). SERVICE PANEL, y,�p��� KAN�q O,Q� PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:706.12(B)(3) 705.12(13)(2)(3)(b) n (, w 095450 4� • SOLAR 4 AROFESSIONP� STRUC NLY LABEL LOCATION: INSTALLED WITHIN T OF RAPID SHUT DOWN SWITCH PER CODE(S):NEC 2017:690.56(C)(3),IFC s u n r u n 2012:605.11.1,IFC2018:1204.5.3 BUILDING SUPPLIED BY UTILITY 4e GRID AND PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED PV SYSTEM(S)ARE 00825-ME 1R CANMGOE ROCK ROAD,YYESiBORY,NY 11590 • • • WITH RAPID SHUTDOWN EQUIPPED WITH RAPID POWER SOURCESHUTDOWN DEVICE(S) CUSTOMER RESIDENCE: LABEL LOCATION: JEFFREY CARLSON INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 5660 SOUND AVE,MATTITUCK, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, NY,11952 ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. 3• TURN RAPID SHUTDOWN PER CODE(S):NEC 2017:690.31(G)(3),690.31(G)(4), $WITCH TO THE"OFF' souaev=mnc a TEL.(631)276-9176 IFC 2012:605.11.1.4 w•AwFas POSITION TO SHUT DOWN APN:1000-121-00-04-00-002-000 PV SYSTEM AND REDUCE PROJECT NUMBER: SHOCK HAZARD IN THE 216R-660CARL. PHOTOVOLTAIC ADISCONNECT ARRAY. e DESIGNER: (415)580.6920 ex3 MAXIMUM AC OPERATING NOMINALOPERATING AC • • VAC LLPV SYSTEM JESSICA ROSS DISCONNECT SHEET LABEL LOCATION: LABEL LOCATION: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF LA EL O MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: SIGNAGE INTERCONNECTION. POINT OF INTERCONNECTION DISCONNECTING MEANS TO WHICH THE PV SYSTEMS (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) PER CODE(S):CEC 2019:690.54,NEC 2017:690.54 ARE CONNECTED. REV:Al 8/10/2023 PER CODE(S):NEC 2017:690.56(C)(1)(a) PAGE PV-5.0 Template wrsbn 4.0.91 Mono Multi Solutions Vertex S PRODUCT:TSM-DE09C.07 BACKSHEET MONOCRYSTALLINE MODULE PRODUCT RANGE:380-405W 405W 0 ^j + 5W 211. 1% MAXIMUM POWER OUTPUT POSITIVE POWER TOLERANCE MAXIMUM EFFICIENCY ..� High value •More productivity from same roof size. •Outstanding visual appearance. •Leading 210mm cell technology. Small in size,big on power s •Small format module allow greater energy generation in limited space. •Up to 405W,21.1%module efficiencywith high density interconnect technology. •Multi-busbartechnology for better light trapping effect,lower series resistance and improved current. •Reduce installation cost with higher power bin and efficiency. II •Boost performance in warm weather with lower temperature coefficient • (-0.34%)and operating temperature. © 00Universal solution for residential and C&I rooftops •Designed for compatibility with existing mainstream optimizers,inverters ® and mounting systems. •Perfect size and low weight makes handling and transportation easier and more cost-effective. •Diverse installation solutions f or flexibility in system deployment High Reliability 0 • •25 year product warranty. •25 year performance warranty with lowest degradation. •Minimized micro-cracks with innovative non-destructive cutting 0 • technology. Q ° •Ensured PID resistance through cell process and module material © • • © � control. • • • •Mechanical performance up to+6000 Pa and-4000 Pa negative load • Trina Solar's Backsheet Performance Warranty • • • 100% 98.0% ■ Trinastandard 3 n 90°/a A 84.8% u' Years 5 10 15 20 25 Comprehensive Products and System Certificates IEC61215/IEC61730/IEC61701/IEC62716/UL61730 °O°E 1509001::Environmental ymanagement nmentalManagstem THnasolar lrlsM! 1��JJ �° 15014001:Environmental Management System C c iA� jg&. 15014064:Greenhouse Gases Emissions Verification �, " ISO45001:Occupational Health and Safety Management System VertexSBACKSHEET MONOCRYSTALLINE MODULE DIMENSIONS OF PV MODULE(mm) 1096 30 1096 1048 I-V CURVES OF PV MODULE(400 W) 14.0 12.0 100bww IIIIIIIIIHI 11.0 4.09x14 10.0 Installing Hole 90 800W/ma Q 8.0 JA -C 7.0 600W/ma d 6.0 u 5.0 4.0 400W/ma .a a o 3.0 to o .=1 2.0 200W/ma 1.0 8-04,3 Grounding Hale 0 30 20 3o 40 50 Voltage(V) P-V CURVES OF PV MODULE(40OW) 8-Oraln Hole 450 400Aog�- 33 1000w/m7 m Front View Back View 350 11.5 Sillcon5ealant 11.5 Slllcon Sealant 300 Laminate Laminate 3 250200 0150 100Frame FrameSO 15.4 0 10 20 30 40 50 A-A B-B Voltage(V) ELECTRICAL DATA(STC) MECHANICALDATA Peak Power Watts-PRm(Wp)e 3BO 385 390 395 400 405 Solar Cells Monocrystalline No.of cells 120 cells Power Tolerance-PH (W) 0-+5 Module Dimensions 1754.1096.30 mm(fi9.O6x43.15x1.181nches) Maximum Power Voltage-VNpp(V) 33.4 33.6 33.8 34.0 34.2 34.4 Weight 21.0 kg(46.3 Ib) Maximum Power Current-IMpp(A) 11.38 11.46 11.54 11.62 11.70 11.77 Glass 3.2 mm(0.13 Inches),HlghTmmmlsslomARCoamdHWSlrengthenedCl- Open Circuit Voltage-Vcc(V) 40.4 40.5 40.8 41.0 41.2 41.4 Encapsulantmateriai EVA/POE Short Circuit Current-Isc(A) 12.00 12.07 12.14 12.21 12.28 12.34 Backsheet Transparent backsheet Module Efficiency A m 1%) 19.8 20.0 20.3 20.5 20.8 21.1 Frame 30mm(l.113 inches)Anodized Aluminium Alloy STC:Imdlance1000Whn2,CeIITempeatureL-CAI,Mass AMI.S.•Neasuring Wlemnce:23%. J-Box IP 68 rated Electrical characteristics with different power bin(referencet010%Irradiance ratio) Cables Photovoltaic Technology cable 4,Omm2(0.006 inches'), Portrait:350/280 mm(13.78/11.02Inches) Total Equivalent power-PMAx(Wp) 407 412 417 423 428 433 Landscape:N1100 mm/P 1100 mm(43.31/43.31 Inches) Maximum Power Voltage-VMPPCV) 33.4 33.6 33.8 34.0 34.2 34.4 Connector MC4EV02/TS4• Maximum Power Current-impp(A) 12.19 12.26 12.34 12.44 1251 12.59 'Pleasereferteregleml&um ntfarvp fled w-, Open Circuit Voltage-Voc(V) 40.4 40.6 40.8 41.0 41.2 41.4 TEMPERATURE RATINGS MAXIMUMRATINGS Short Circuit Current-Isc(A) 12.92 13.00 13.08 13.20 13.25 13.36 NOCT(NominalOper VgQnTempereture) 43-C(±2-C) Operational Temperature -40-+BS'C Irradiance ratio(reartfront) 10% Temperature Coefficient of PmA -034%/eC Maximum System Voltage 1500VDC(IEC) PmeralfaclaW..7od5%. Temperature Coefficient of Voc -0.25%/°C 1500VDC(UL) ELECTRICAL DATA(NOCT) Temperature Coefficient oflsc 0.04%/eC Max Series Fuse Rating 25A Maximum Power-PMAx(Wp) 286 290 294 298 302 305 ' WARRANTY PACKAGING CONFIGUREATION Maximum Power Voltage-VMpp(V) 31.4 31.6 31.6 31.9 32.1 32.4 25 year Product Workmanship Warranty Modules per box:36 pieces Maximum Power Current-IMpp(A) 9.12 9.1B 9.24 9.32 -9.3B 9.42 25 year Power Warranty Modules per 40'container.828 pieces Open Circuit Volta ge-Voc(V) 38.0 38.2 38.4 38.6 38.8 38,9 2%first year degradation Short Circuit Current-Isc(A) 9.67 9,73 9.78 9.84 9.90 9.94 0.55%Annual Power Attenuation NOCr:IrradlanceategOW/e.AmbientTempemWrezO'CWlndspeed lMs (Plemerefertopmdutt-tyfordeulls) CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Trinasolar m2022Trina Solar Co.,Ltd.All rights reserved.Specifications included in this datasheetare subject tochange without notice. Version number:TSM_NA-2022-A solar=@@ • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE330OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US solar•••: "1 �J solar, ,r 1D-,., �pV arfe�, ® ®o a a - ajai Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring 11111111111'D Outdoor and indoor installation wave Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us sola r ' • • w. Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US _ I SE3000H-US SE3800H-US 1 SESOOOH US SE6000H-US SE760.OH-US SE30000H US SE11400H US OUTPUT Rated AC Power Output 3000 3800 @ 2401 5000 6000 @ 2401 7600 10000 11400 VA 3300�1a,2081 5000 2081 ............. . ... . Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300,E 2081, , 5000 2081 .......... . ... .. AC Output Voltage Min.-Nom.-Max. Vac ..(.183,=208„24......................... .........I.... ................ ............... ................ I.............. ................ ................ ........... AC Output Voltage Min.-Nom.-Max. .1 ,/ ,/ Vac (211„240,-264)......................... ............... ................ ............... ................ ............... ................ ................ ........... AC Frequency(Nominal................. ............... ............................... 59.3_60: 60: 51� 1... ........... . . .............. ................ ... ...... Maximum Continuous Output Current 16 24 A 2081...............I..................... ............... .............................I. ................ ............... ................ ................ ........... Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A ..1?e.2401................................... ............... ................ ............... ................ ............... ................ ................ ........... GFDI Threshold 1 A .... g...........I......... ...........................I............................Yes....................................................... Utile Monitonn Islandin Protection, Country Configurable Thresholds — INPUT Maximum DC Power @2401 4650 5900 7750 •....7750 11800 15500 17650 W..... Maximum DC Power @2081 5100 f ............... ........ Transformer-less,Ungrounded Yes ....................................................... ........... Maximum Input Voltage 480 Vdc ....... ................................................................ ................................................. .... Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 2081 9.... 13.5.... .......... Maximum Input Current @2401......... ......8:5......1......10:5......1......13.5.....1......16.5...... ......?.0......1.......?T......1......30.5...... ...Adc.... Max:In ut Short Circuit Current 45 Adc Reverse-Polarit Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity ............................................ .. ...... ............................................... ........... Maximum Inverter Efficiency............. ......99......I .............99:2 .. .................................. .............................................. CFC .........................................................99... ...... Nighttime Power Consumption_ v <2.5 W _ ADDITIONAL FEATURES Supported Communication Interfaces RS485:Ethernet,ZigBee(optional),Cellular(optional) .......................... ................... ........... ..Revenue Grade Data,ANSI C12.20 ....... O.ptionall2l...... ..... ..... ......... ................. ..... ........... . .................................... Rapi.. d Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE — Safety UL1741,UL1741 SA,UL1699B,CSA C22.2:Canadian AFCI according to T.I.L..M....-.0..7 .................... ........... ......... .......... ........................ Grid Connection Standards ., .... .•. IEEE1547,Rule 21,Rule 14(HI) _.. .. ........................................ ...................... Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS __ AC Output Conduit Size/AWG Ranee 3/4"minimum/14-6 AWG 3/4"minimum/144 AWG . ........... DC Input Conduit Size/#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/ AWGRang@.............................. .................................................................................1. 14.-6 AWG........... ........... 21 Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 3x14.6x7.3/540x370 X.185 i ' n/mm ........................................ ....................'............ Weight with Safety Switch............... ............?2�.10............�..25:1. 11:4.. ...........26.2/11.9.......... ...........38:8/17:6........... .lb l.kg... <50 dBA Noise..................................... ...........<25 ........... .................... .................... ....... Cooling Natural Convection Natural convection ......... ............ ................................................ Operating Temperature Range -13 to+140/-25 to+60131(40 F/.40'C option)I4� °F ........................ . ... Protection RatingNEMA 3R(Inverter with Safety Switch 111 For other regional settings please contact SolarEdge support 1xi Revenue grade Inverter P/N:5Ex)=H-US000NNC2 131 For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf 161-40 version P/N:SExxxxH-US000N NU4 ■ oHS 'r Q SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE iare trademarks or registered trademarks• •_ •Technologies, Date:are trademarks 01 their respective owners, • • ..',aww,,, .+. ,1„„,r..:- .. ., ..*;'amu"�;,,,,,. �+!' •1 ti d Al s; w M ; 777- Y J 7 yr < �•H�• ., s'� ..7. � �9't��-`-.. '91:x"_" v,r � ,j . F axM 011 ARM I System designed with All parts fit in a box for easy maximum versatility for any logistics arrays including staggered Drop-in features make the install process intuitive and fast Simple design allows system to be installed by single installer U Listed to UL Standard 2703 for on the roof Grounding/Bonding Groundin and Fire g/ g Classification SnapNrack RL Universal is designeclAo provide the fastest, most intuitive install experience for residential roofs. The direct'mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the highest spans of any current rail less system. J Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical.seal • Flash track is designed for maximum versatility with 6 inches of North-South adjustability for all Mounts Mounts • Single mount used at all locations on array • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments ; i Links • Simple design provides mounting platform between two to four modules NIS. • Clamps onto top of modules securing them in place while providing ► row-to-row bonding • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules • Skirt length is compatible with both portrait and landscape module orientations Quality. Innovative . Superior, SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources • improve overall installationquality and . • o • 9 by SnapNrack Solar Mounting Solutions.All rights reserved DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins sna p N mall REVISION: PART NUMBER(S): A 595 MARKET STREET,29TH FLOOR.SAN FRANCISCO,CA 94105 USA PHONE(415)580-6900.FAX(415)580-6902 242-02155 THE INFORMATION IN THIS DRAWING IS CONFlOENIIAL AND PROPRIEfMY.ANY REPRODUCTION,DISCLOSURE,OR USE THEREOF IS PROHIBITED WRHOUTTHE WRRTEN CONSENT OF SUNRUN SOUTH i5s 0 0 4 3 9 7 ® 8 a" 1 2 o 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1IN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 DESCRIPTION: DRAWN BY: • SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins snapHrack REVISION: PART NUMBER(S): A 595 MARKET STREET,29TH FLOOR.SAN FRANCISCO,CA 94105 USA PHONE(415)560-6900.FAX(415)580-6902 242-02155 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY.ANY REPRODUCTION,DISCLOSURE,OR USE THEREOF IS PROHIBITED WITHOUT ME WRRTEN CONSENT OF SUNRUN SOUTH LLC. 1.50—►I 3.41 1.50 FS; 2.35 1.50 1.55 .66 42.00 1.24 1.00 SLOT s, ?2.63 1.50 ALL DIMENSIONS IN INCHES