Loading...
HomeMy WebLinkAbout50309-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPRO'V'ED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50309 Date: 2/6/2024 Permission is hereby granted to: Moraski, Lauren 142 Suffolk St Unit B New York, NY 10002 To: construct alterations to an "as built" finished basement of an existing single-family dwelling as applied for. Additional certification may be required. At premises located at: 825 Cedar Dr, Southold SCTM #473889 Sec/Block/Lot# 78.-7-37 Pursuant to application dated 1/17/2024 and approved by the Building Inspector, To expire on 8/7/2025. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $714.40 CO-ALTERATION TO DWELLING $100.00 Total: $814.40 Building nspector � r TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 h Telephone (631) 765-1802 Fax(631) 765-9502 htt s://www.seuth Irltownn L'ov Date Received APPLICATION FOR BUILDING PERMIT „. .. . n. �arOffice Use Only PERMIT NO. Building Inspector. J MN Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where'the Applicant is,not the owner,an Owner's Authorization form(Page 2)shall be completed.: Date: OWNER(S)OF PROPERTY: Name: } SCTM # 1000- �`1 �I r� Project Address: 8 Cedar Dr 1 W- rr v ] Phone#: y 1 D �1 y of EmaiI:GTC�I 1" Y�,I �. �:�V►�1 Mailing Address: CONTACT PERSON: Name: �r Ci5 C C? �avC�bt Mailing Address: V.0 .. bojj J l4 Phone#: 1 ) ` -}q —o l±•1 5 Email: ylCi`SCG4 �iGc�oJ� _G�vy1 DESIGN PROFESSIONAL INFORMATION: Name: I VVl )LI f'sse Mailing Address:5g (j/bfkCLY✓l f_OCLa -,5Vi©r i� Iv7' 5 t�d a� Phone#: 0 '" �`� �� Email: ..hwC` coy" CONTRACTOR INFORMATION: " Name: 5P-Plg6d f4 CO%q s-1 f uc 01-) Znle Mailing Address: Phone#:(3 01 /3 Email: ) Cln�S� 1 Gc�IC7% Cory, DESCRIPTION OF PROPOSED CONSTRUCTION , ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition E stim toCost of Project: ❑Other Will the lot be re-graded? ❑Yes IKO Will excess fill be removed from premises? ❑Yes 416 1 PROPERTY INFORMATION Er.j '` j 45rY'yj,& Existing use of property: f a �� Intended use of property: Zone or use district in which premises situated: Are there any covenan ad restrictions with respect to this property? OYes E No IF YES,PROVIDE A COPY. O Check Box After Reading: Thewar/ fdetdpr prufmim"a mspw affik*W ad drawee ani atone water him a pmd&d by chopw 236 of the Town Code.Apnx mON is mm mAw to the 9wom Department for the bannoe of s emuft Fera purrialet to the 7Arr or&moca of the Town ofSoulbaK Stdfok OmN.New Ywk and otherappoble taw;Ordnanm ar Repdadw%ford*cor&ucdon of bU dgp6 addom,akeratlmu a for mower w dewmad r as herein detceaLThe opokart apse to comply whh aN applobb bm or&wnm%bWW%coda. hoosracode and repdadont and to admR authorwd hppectors on promim and In kdktm&l fwwcenarr kupecdam Fake st lEffle s made hereto are p rAdubte as a Gam A misdemeanor purswntto MOM ZJQM of the New York State final taw. Application Submitted By(print name): <J OS e- i DAuthodzed Agent Downer Signature of Applicant: �+ 1 D\ Date: CONNIE D.BUNCH Notary Public,State of New York STATE OF NEW YORK) No.01 BU6185050 SS: (qualified in Suffolk County COUNTY OF l Commission Expires April 14,'?�l being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contrail)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said workand to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth In the application file therewith. Sworn before me this 20aLLD Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) 1 91(1yµ / residing at S2 S, Lav 119 7( do hereby authorize - S to apply on my behalf to the Town of Southold Building Department for approval as diescri herein. Owners Signature Da ( 11h &A�44r Pont s Name 2 SS�SS�s S C-1 825 0 A S 0 - A -i,- , 0 _110 _L �! , L�_Jl _ V.� �,__J, 0 -I, ,- _L_J _L L A , V_ RuSO 0 D_\4 0 A K 0OI& u 0 9 9 W YO � K LEGEND ABBREVIATIONS LIST OF DRAWINGS GENERAL NOTES AND SPECIFICATIONS-RENOVATION 4.1.2 Install 3"PVC"T"fitting in sub-slab aggregate or in sump pit and connect to & AND DIVISION 1—GENERAL NOTES independent 3"vent stack located in wall and penetrate through roof Run pipe in ® BRICK ® AT 1.1.1 All work is to be performed in accordance with all applicable codes,ordinances a manner that makes it accessible for installation of a fixture in-line vent pipe fan # NUMBER OR POUND and accepted industry standard. Carefully coordinate with permitting officials in the attic space. Pitch pipe to drain and provide an electrical box for future and conform to all specific towns ordinance related to demolition and wiring if required_ Locate pipe outlet as required by code.Provide one per 1,500 A F.F. ABOVE FINISHED FLOOR construction protectionsuch as construction fcnc � etc. sf of basement or crawls ace area. CONCRETE ADJ. ADJUSTABLE P n' inP A.P. ACCESS PANEL T-1 LEGEND & SPECIFICATIONS 1.1.2 All engineering documents,specifications,and details shall supersede information DIVISION 6-ROUGH CARPENTRY APPROX. APPROXIMATE T-2 SPECIFICATIONS � g Pe P C.M.U. A-1 DETAILS & as noted on the architectural doctunents. Section 6.1 -General Carpentry Materials BA. BY OWNER BASEMENT/FOUNDATION PLAN 6.1.1 Structural Framing lumber to be No.2 Douglas Fir,or better, 1450 psi minimum, BLDG. BUILD NG 1.1.2 Contractor is to verify all dimensions and conditions in the field and notify the factory marked,or metal studs at all basement areas. i EARTH OR COMPACTED FILL ROCK Bim. BLOCK Architect of any discrepancies or inconsistencies prior to executing construction_ BM. BEAM 6.1.2 Pressure Treated lumber to be in accordance with AWPA AmericanWood BOT. BOTTOM BUILDING 11.3 Do not scale drawings. Written dimensions take precedence over depicted sizes Protection Association Standard U1 as follows with special attention to allowable INSULATION BAITS BRKT. BRACKET ) P BSMT. BASEMENT CHARACTERISTICS and relationships on drawings. Variations in drawing size may take place due to fasteners and flashing_ drafting and printing processes. INSULATION RIGID C.B. CATCH BASIN INET Preferred Sill plates:Sillbor"borate treated wood"by Lonza Wood CLG. CATCH Code J LJ rl S d I Ct I O n 2020 RESIDEMAIL CODE 1.1.4 All dimensions are given to face of gypsum board unless expressly noted Protection CL CLOSET OF NEW YORK STATE otherwise. Windows and exterior doors are located by centerline. www.wolnuanizedwood.com POROUS FILL CONE. CONCRETE Use Group u R-3 1.1.5 Contractor to perforin in high quality professional workmanlike manner. Alternate Sill late: Wohnauized Residential Outdoor Wood by Lonza DEPT. DEPARTMENT P p DIA. DIAMETER Wood Protection treated with.05 CA-C(copper ® STEEL DIM. DIMENSION 1.1.6 Contractor to coordinate and accommodate"Not in Contract"work. ON. DOWN Const. CIasS. 5 B Including accepting and unloading of all items. azole)rated for above ground. DWG. DRAWING wwtv.tivohnanizedwood.com WOOD BLOCKING E. EXISTING 1.1.7 Details noted"Typical"imply all such conditions to be treated similarly_ Section 6.2-Carpentry Installation: ELEC. ELECTRICAL 30 Ib/sq. ft. live 6.2.1 Comply with"WCD 1 -Details for Conventional Wood Frame Construction"b EQ. EQUAL Floor Loads 1.l.8 Contractor shall furnish a Certificate of Occupancy to the Owner at the time of P Y Y ® 10 Ib/sq. ft. dead P Y American Forest&Paper Association/American Wood Council(awe.org)and WOOD FINISH Sleeping Areas "Substantial Completion'. F2F FLOOR TO FLOOR 40 ib s ft. live IRC International Residential Code,New York Edition,including nailing, F.D. FRENCH DOOR FI o o r Loads / q firesto in ane F.F.D. FROSTED FRENCH DOOR Other Areas 10 Ib/sq. ft. dead 1.1.9 Contractor shall procure and payfor all permits and fees. PP g- hora0 e,framing and bracing. Code requirennents for spacing, EXISTING TO REMAIN FD FLOOR DRAIN si7jng,spaus and cuts shall be strictly observed. F.E. FIRE EXTINGUISHER 30 Ib/sq. ft. live Roof Loads s f live 1.1.10 1 ll co are anDrawings, ,a i remain cificutions,Copyrights and the Designs expressed 6.2.2 Refer to details I &2 on sheet A-1 for typical beam bolting layout detail and EXISTING TO BE REMOVED FF FINISH FLOOR10 Ib/sq. ft. dead P g �•Pe PYrg g � P Wroe of the Architect. The are to be used FIN. FINISH I' P rtY Y typical Microllam L.V.L.and Paratiam PSL penetration gusset detail. See detail 4 NEW WALL FlNISH FLR. FLOOR Bathroom th ro o m 40 Ib/ q. t. li only with respect to this project. on sheet A-1 for the joist penetration location detail. FT. FOOT OR FEET 20 Ib/sq. ft. dead EXISTING STRUCTURE LINE 1.1.11 All work is new unless noted as existing. G.C. GENERAL CONTRACTOR6.2.3 All piping and electrical penetrations shall be centered in joist depth NEW STRUCTURE LINE GA. GAUGE GALV. GALVANIZED 1.1.12 Contractor shall protect all existing to remain construction during all phases of 6.2.4 All structural work shall be literal as per these documents. GRADE LINE GYP. BD. GYPSUM WALLBOARD work and repair any existing to remain conditions that are damaged during the H.B. HOSE BIBB construction so as to match existing pre-construction condition. 6.2.5 Verify existing structure before any removals:notify architect. GRADE LINE CHANGE HT. HEIGHT 1.1.13 Furnish Port-O-John on site for cnration of construction.HVAC. HEATING, VENTILATING, 6.2.6 Unless otherwise stated on the drawings,headers shall be as follows: AIR CONDITIONING Up to 6'-0"opening: use(2)2 x 10's SYMB 0 LS I.D. INSIDE DIAMETER/ Up to 10'-0"opening use(2) 1 3/"x 9'/2"L.V.L's DIMENSION IN. INCH Z 4 INT. INTERIOR o SECTION DESIGNATION LAM. LAMINATE SECTION NUMBER LV.L LAMINATED VENEER LUMBER SHEET NUMBER MFR. MANUFACTURER MIN. MINIMUM ELEVATION DESIGNATION MISE. MISCELLANEOUS ELEVATION LETTER N. NEW SHEET NUMBER N.I.C. NOT IN CONTRACT NO. NUMBER W CENTERLINE N.T.S. NOT TO SCALE 1.1.14 Cleaning shall be the responsibility of the General Contractor. Floors,walls, d windows,and all other surfaces sliall be cleaned ready for occupancy,including The values do not 1 to conditions with framing comers or loaded posts above. A O.C. ON CENTER apply g Po- O DOOR TAG, SEE SPEC. O.D. OUTSIDE DIAMETER/ removal of all labels on window and doors. Turn over building broom clean. The DIMENSION owner will wash windows and pkumbing fixtures. 6.2.7 Unless otherwise stated on the drawings,hangers shall be as follow=s: 20'sgts_o.c.. JOIST TAG OZ. OUNCE cLG.ABM P.D. POCKET DOOR 1.1.15 All materials shall be new and of the grade and quality specified. Trained, 2 x 8: Simpson LUS28 PLUMBING TAG, SEE SPEC. Simpson O PL PLATE experienced persons,skilled in their various crafts shall perform Work. (2)2 x 8: Si son LUS28-2 � P-LAM POWER LAMINATE MEMBER 2x 10: Simpson LUS210 O P.R. POWDER ROOM 1.1.16 The entire installation shall be guaranteed against defects in workmanship and (2)2 x 10: Simpson LUS2l0-2 E' REVISION NO. PT. PRESSURE TREATED a material for a period of one year from the date of final acceptance. (3)2 x 10: Simpson LUS210-3 ►- R. RELOCATED 2x 12: Simpson LUS210 ray ,-� RAD. RADIATOR 1.1.17 Existing conditions shown or implied are based on best available but limited 11-7/8"T31 560: Sim TUS3.56/11.88 \/ son SCALAE- ?? DETAIL TAG REC. RECESSED P w information. REF. REFRIGERATOR nformaon. If conditions are encountered that differ from those shown,noted or 14"TJI 560: Simpson IUS3.56/14 Q 12 REQ. REQUIRED implied,all work in that specific area is to stop and the Architect is to be notified. 1-3/4"x 9-1/2"LVL Simpson IIUS1.81/10 Z ROOF PITCH TAG RMREV. ROOM ION No work is to continue in such areas without the permission of the Architect_ 1-3/4"x 11-7/8"LVL Simpson IiUS1.81/10 � 1-3/4"x 14 T.VL Simpson HUS1.81/10 A A R.O. ROUGH OPENING 1.1.18 All allowances/credits shall be for the actual purchase price of the items. 3-1/2"x 9-1/2": Simpson HI-1US410 5 BUILDING SECTION S. SOUTH 3-1/2"x 11-7/8": Simpson HHUS410 SCHED. SCHEDULE 1.1.19 General Contractor shall procure and pay for building layout and building height 3-1/2"x 14": Simpson HHUS410 SIM. SIMILAR SI APSON TOP FLANGE HANGER SPEC. SPECIFICATION survey. 3-1/2"x 18: Simpson HU416/IIUC416 �' SPKR. SPEAKER 5-1/4"x 9-1/2": Simpson HI-IUS5.5/10 SIZED AS REQUIRED SQ. SQUARE 1.1.20 General Contractor shall procure all other survey work(if required)including but 5-1/4"x 11-7/8": Simpson HHUS5.5/10 HtB. HOSE BIB S & R SHELF & ROD not limited to a foundation location survey. The owner shall be invoiced directly 5-1/4"x 14" Simpson IIIIUS5.5/10 S.SINK SERVICE SINK for these items. 7"x 9-1/2 Simpson HMJS7.25/10 P OUTLET S.T. STEEL TUBE QUAD OUTLET SIL. STEEL 7"x 11-7/8" Simpson IIIIUS7.25/10 S.S. STAINLESS STEEL DIVISION 2-DEMOLITION 7"x 14" Simpson IIIIUS7.25/10 Z use LEVITON, MODEL #75632 STOR. STORAGE 2.1.1 Demolish all wall,ceiling and floor surfaces in all spaces where work occurs (3)1-314"r 9-1/2"LVL w/ Simpson HWU7.12/9.5 SYM. STRUCTURAL utilizing The Lead-Safe Certified Guide To Renovate Ri ht"docuunent criteria 2 5/8"Steel Flitch Plates � 0cFl GFl PROTECT OUTLET SYM. SYMMETRICAL g�� g ( ) t4'P/GFT T. TREAD as issued by the EPA most current addition. W WATER PROOF On PROTECTED OUTLET TEL. TELEPHONE 6.2.8 Verify sizes of all engineered structural members,indicated on drawings,with 0► PHONE (TWO LINE HOME RIJN, CATEGORY 6, TEMP. TEMPERED 2.1.2 Remove and dispose of all waste material in a legal manner including separate architect prior to ordering and installation. t 4 TWISTED PAIR) T&G TONGUE AND GROOVE dmmpsters for construction debris and masonry material. Additionally provide .. ®z CABLE - RG6 QUAD SHIELD - RG6QS (HOMERUN), THK. THICK two lockable lid garbage cans ou site for food waste and commingled recyclables. 6.2.9 All plates to be doubled with splices staggered over studs only.PHONE (DEFINED ABOVE) T.O. TRIMMED OPENINGT.V. TELEVISION 03 2 HDMI CABLES, IR WIRE, CABLE (DEFINED ABOVE), I. TYP, TYPICAL 2.1.3 Disconnect all plumbing,electric,and heating to point of last use. 6.2.10 Provide double joists minimum under all walls parallel to joist length unless F�A�,�fy OF buy PHONE (DEFINED ABOVE) specifically noted otherwise. M 1."7 Rl.1ll�UTFiOR12E+J p[r. U.O.N. UNLESS OTHERWISE 2 HDMI CABLES, IR WIRE, PHONE (DEFINED ABOVE) NOTED 2.1.4 General contractor shalt assume all responsibility in reference to the removal and + L _E J�� V=6. relocation ; relocation of all existing to remain mechanical,pluumbing and electrical services 6.2.11 Double framing around all openings where not indicated on drawings. ; ala. GAS OUTLET, PROVIDE DANTE VALVE AT ALL VERT. VERTICAL exposed due to removal of existing partitions. FIREPLACE LOCATIONS, FINISH AS SELECTED B.O. V.I.F. VERIFY IN FIELD 6.2.12 All joists to have 3 '/2"muuimum bearing over plates or as otherwise indicated on ------ O S.D./C.O. 120 VOLT SMOKE / CARBON MONIXIDE DETECTOR W WEST DIVISION 4-UNIT MASONRY drawings. Flush beam and headers to have metal hangers_ ® CONSTRUCTION SET 08/29/2023 0S.D. 120 VOLT SMOKE DETECTOR W/ WITH Section 4.0-General Conditions WD. WOOD 6.2.13 All framing members where cut to permit passage of piping,ducts,conduit,etc. dh- DOUBLE HUNG WINDOW W.I.C. WALK IN CLOSET 4.0.1 No masonry work shall be performed if day or night time temperatures are shall be strapped and braced on each side as per code requirements. Provide / CASEMENT WINDOW W/o WITHOUT expected to fall below 32 degrees Fahrenheit. miscellaneous framin around openings as re Tired. A c- WP. WATERPROOF aW- AWNING WINDOW Section 4.1-Fooling/Concrete SIabs gm �,���pt T` �' �• f- FIXED WINDOW RECESSED MEDICINE CABINET 3 S 14i �� WALL TO BE FREE OF ALL PLUMBING 12� VERIFY SIZE WITH OWNER A4.CaivTAa- 'y-. (��.7 "19 027f1f� CI N �.� a o g g T - 1 DATE 08/29/2023PROJECT No 23 014 snET 1 OF 3 MnRA.q T 82" 5 '1 7 7 C1 F yolq 0V ou -10 N W L L S0V10A4� K 9 9 6.2.14 All doors or trimmed openings to have(2)-2"x 4"or(2)-2"x 6"studs at jambs Section 9.1 -Drywall equals. Seal all joints and corners,including prefabricated joints and longitudinal must be installed. Low voltage system to be famished and installed by owner. minimum,verify wall thickness with pans. seams. Submit cut sheets for alarm panel and all devices to building department for 9.1.1 Install Gold Bond Brand'/a"XP Mold/Moisture Resistant Gypsum Board by approval. 6.2.15 All framing shall be plumb and square,true,well braced,pinned together with National Gypsum Company(704-365-7300)at walls and ceiling throughout scope 15.1.6 All ductwork branch take-offs are to be complete with balancing dampers. good joints and true bearings. Framing and nailing shall conform to I_R_C.-N-J. of work. Install Wonderboard on all areas to he tiled. Attach all gypsum boards 16.1_I7All decorative fixture(lighting legend items 7 and 8)shall be located after and good practice. with construction adhesive and drywall screws. Attach all wonder board with 15.1.7 G.C.to furnish and install ductwork as required,to exterior,for kitchen exhaust gypsum board has been installed,with owner and architect. approved fasteners. All basement gypsum board shall be lifted off slab 2"to supply and makeup air. 6.2.16 Use subfloor grade construction adhesive at plywood subfloor installation and prevent wicking. Seal all wonder board seams,edges and perimeter with Lexel 16.1.19General Contractor shall furnish and install Pro/Tran 30310A(30 Amp 10 underlayment grade construction adhesive at plywood underlayment installation. Clear All Purpose elastomeric compound manufactured by Sashco 800.289.7290 15.1.8 G.C.to fairish and install insulated(min.R-6)ductwork, as required,to exterior, Circuit)manual transfer switch,power inlet box,and all required accessories as and available at Jaeger Lumber 973.377.1000. for bathroom exhaust fans. manufactured by Reliance Controls Corporation,800-634-6155 for owner's 6.2.15 Exterior dimensional trim shall be WindsorOne Protected. Contact Dykes generator with automatic voltage regulation. Lumber(201-867-0391)for assistance with WindorOne trim.primed all sides by 9.1.2 General contractor shall apply three coats of spackle to gypsum board and treat or 15.1.9 All ducts in the outside walls and unconditioned areas shall be insulated with 1" G.C.prior to installation. Exterior running trim shall be clear pine,primed all sand surface to match the existing finish texture to meet satisfaction of architect thick fiberglass wrap with vapor barrier. Exterior/Specialty Door Schedule sides by G.C.prior to installation.(Unless otherwise noted in documents) and owner's painter. Tag Description Field verify all diffuser Locations with owner and architect before 6.2.17 Interior trim shall be clear pine or poplar,continuous pieces,no finger jointed 9.1.3 All painting,interior and exterior,shall be by owner unless otherwise noted in installation.Align diffusers with centerline of light fixture and coordinate A 6'-0"x 6'-8"Pella double pane SDL sliding door and 2"thick oak saddle.Verify trim_ (Unless otherwise noted in documents) these specifications_ with architect. hand with owner before ordering. 6.2.18 All trim including door,window,window sills,base,casing,crown and exterior 9.1.4 Perfectly patch all wall,ceiling and trim surfaces as required to be ready for paint Section 15.2-Plumbing Door Schedule Notes: shall match existing.(Unless otherwise noted in documents) by owner including removal of existing wall liners. 15.2.1 General:Provide design/build plumbing system to conform to tlue National All doors(unless otherwise noted)shall be Simpson as supplied by Reeb Millwork Standard Plumbing Code and applicable requirements of any local codes having Corporation. Contact Steve Gerard(201-376-1814) 6.2.20 All shelves shall be%/ thick MDF with all exposed edges to be eased and sanded Section 9.3-Marble/Slate/Ceramic Tile jurisdiction. smooth. Install on continuous 1 x 2 cleats with all exposed edges to be eased. 9.3.1 Standards:Adhesive and grout materials and installation standards of the All insulated glazing shall be'/2"thick argon filled only:no Low-E glass The rod shall be 1-1/4"diameter polished chrome. Provide intermittent supports American National Standards Institute(ANSI)and Handbook for Ceramic Tile 15.2.2 All waste shall be no hub cast iron,vent pipe shall be P.V.C.and vent penetrations as required at spans greater then 5'-0" Installation by the Tile Council of North America,(current Edition)apply to the through roof shall be copper;all water risers shall be'/"copper with'/2"copper Refer to elevations for transom locations. work,except as otherwise noted. supplies(plastic piping is an approved substitute). If plastic piping is utilized 6.2.21 Provide bridging as specified below provide manifold in mechanical room with homeruns to all locations and separate All Simpson doors shall be bored to receive traditional hardware manufactured by others Dimensional Floor Joists: 9.3.2 Contractor torovide ceramic tile installation at all areas as indicated on the shutoffs. All gas piping shall be black pipe or frac pipe. All copper piping shall -Solid wood bridging centered in spans of floor joists exceeding P be Type`L'. Size as r uired. (do not utilize Simpson's three point locking system hardware) drawings. Tile and grout as selected by owner. Tile at floor and wall conditions YP ixl 8'-0". shall be set in troweled latex portland cement mortar. Sub-straight shall be as Plumbing Fixture Legend and Notes follows: 15.2.3 General Contractor shall have a certified chimney inspector,inspect all existing to Tag Description 6.2.22 New handrails and balusters as shown on details 6&7 on sheet A-1. remain flues for compliance to the building code and provide an additional cost to Floors: Direct adhere over 1/4"cement backer board the owner without markup to modify the flue if work is required. 6.2.23 Repair and or replace all exterior trim as required due to rot and or new window (no or equals)installed as per manufacturers directions to A Toilet-Toto toilet MS854114S and seat(elongated model). work. 15.2.4 Install new sewage ejector it Liberty Pum Pro370-Series with rckTree B Laundry cabinet-Silestone top. Plastic-laminate base and upper cabinets. achieve a flush floor condition g J P rtY P Qu Walls: Direct adhere to``/z"cement backer board. Technology and pump sized as required(www.libertwumps.com-800-543- C Full width frameless minor. Make mirror the same size as the cabinet and 6.2.24 Laser-level all ceilings and floors with adequate furring as required. > » 2550 . Provide ower and plumbing as required. Cut and patch all surfaces with top below. Shower Area: Direct adhere over/a cement backer board ) P P g q (no or equals)installed as per manufacturers directions like materials as required due to running services. D Vanity-Stone top with built in Kohler K-2214 linear x 12")rectangular DIVISION 7-THERMAL AND MOISTURE PROTECTION Shower Floor: Direct adhere over cementious sloped base(sloped to drain) umdermoumt sink on wood cabinet allow$400/llinear foot,allow$600 per Section 7.2-Building Insulation over rubber membrane over cementious sloped base 152.5 Furnish and Install 75 Gallon Power Direct Vent quick recovery water heater by faucet E Stall shower-tile shower floor,ceiling and walls with chrome-framed 7.2.1 Maintain ventilation space at all eaves_Provide insulation baffles as required. (sloped to weep holes)See detail on A-sheets. AO Smith or equal. glass enclosure with 6"soffit to match curb below. Allow$600 for Basement Slab: Direct adhere over bed of thin-set. mixing valve. 7.2.2 Provide minimum insulation R values as indicated below,unless values areDIVISION 16-ELECTRICAL/FIRE LH+'E SAFETY F Laundry Machine-Silestone top above front loading washing machine. superseded by ResCheck calculations.(General contractor shall verify ResCheck 9.3.3 General Contractor shall install marble saddles at all door openings where marble Section 16.1-General Plastic-laminate fillers as required. calculations before proceeding with insulation) or rile has been selected,see plans. Style as selected by owner. 16.1.1 General:Provide Design/build electrical system to comply with the National Electrical Code,Underwriter's Laboratories and all other authorities having 6 8 10 12 Section 9.4-Painting jurisdiction including the installation of ground fault outlets,tamper proof outlets Flooring Material Legend 7.2.3 Provide kraft faced fiberglass batt Greenguard Certified insulation with R values 9.4.1 Contractor shall include rimmi of exterior trim prior to'installation,exterior and are fault protection, including the installation of outlets and switches in P g P � Tag Description as follows: doors and fascia/soffit boards,with one coat of Benjamin Moore Fresh Start locations that are not indicated on the documents however are required to acrylic latex(023)and Painting of MasterSeal 583 on basement walls. comply with the requirements of the building codes. 1 Ceramic tile: allow$1500 for tile and grout only.Extend tile on floor and Rafter Ceilings(2 x 8) R-21 full height on walls in tub/shower area. Furnish and Install(1) 11"x 14"x 2 x 4 Stud Walls R-15 9.4.2 Seal all new full basement walls and garage walls with a water-proofing 16.1.2 Furnish Lighting fixtures as indicated on the"Lighting Legend"(No 3-3/8"ch.depth shower niche as manufactured by KBRS,Inc(866-912- 2 x 6 Stud Walls R-21 membrane paint(MasterSeal 583)and seal concrete garage floor with Behr Substitutions)and provide appropriate lamps for specified fixtures. 3211).Seal at completion of work. 2 x 10 R-30 concrete&garage floor paint: 1 part epoxy acrylic. 2 Adura Max LVT/WPC(6"x 48"locking)Plank flooring as 2 x 12 R-38 16.1.3 Label circuits on circuit breaker panel. Note: In attic spaces where no sub-floor exists above provide R-38 batt 9.4.3 All other painting is not in contract although contractor is to provide paint read manufactured by . w,.vw.mannington.com/residentiaI Flooring color,shade and design as P g g P P Y selected by owner. www.mannington.com/residential / 1-800-356-6787. insulation. surfaces. 16.1.4 All RX wiring with plastic boxes. General contractor to prep all floor surfaces as required and to follow 7.2.4 Provide 3"thick sound attenuation blankets at all partitions surrounding and DIVISION 10-SPECIALTIES 16.1.5 Verify all device locations with owner and architect before wiring. manufacturers installation instructions. floors below bathrooms and around all water and sanitary pipes. Section 10.3-Bathroom Accessories 16.1.6 All switches,receptacles,and plates are to be"Decora"series by Lightolier or 7.2.5 All caulking shall conform to F.S.TT-C-598 Grade 1,color to be selected by 10.3.1 Contractor shall install bathroom accessories as furnished by owner. G.C.to equal. Provide dimmers as indicated,color as selected by owner. Architect. provide blocking as required. 16.1.7 Install new"Decora"devices in existing to remain electrical device and outlet 7.2.6 Seal all thresholds in sealant. Caulk and seal all windows,doors,and joints. 10.3.2 Install accessories in accordance with manufacturer's instructions,using fasteners locations. appropriate to substraight and recommended by manufacturer of unit. Install 16.1.8 All down-li ht frame in kits in insulated ceiling conditions shall be"insulated Section 7.5-Flashing plumb and level firmly anchored in locations to be chosen by owner in field. ceilingg g 7.5.1 Concealed-Provide minimum 16oz.aluminum step flashing.Shop brake where "type housings for buried in insulation conditions. creases are visible. Separate from dissimilar metals with bituminous coating. DIVISION 12-FURNISIIINGS (Aluminum flashing shall not be used when in contact with Treated lumber) 16.1.9 All light fixtures shall have LED bulbs sized as required with color temperature of Section 12.1-Cabinetry 2700k and Color Rendering Index of 93, these bulbs are manufactured by FEIT 7.5.2 Exposed-Provide minimum 16oz.copper flashing.Shop brake all creases. 12.1.1 All bar cabinets,tops,appliances and installation is by owner. G.C.to provide Electric, www.feit.com_ Separate from dissimilar metals with bituminous coating. roughing and final hook-ups. Coordinate with owner's cabinet vendor and closely follow cabinet vendor's drawings. Match cabinet vendors drawings with respect 16.1.10All light fixtures furnished by owner shall have bulbs furnished by owner DIVISION 8-WOOD DOORS/WINDOWS&HARDWARE to all trades. Allow architect to sign off on all changes from the most current Section 8.1-Wood Doors & Hardware drawings available. 16.1.11 General Contractor shall furnish and install I IOV thermal photoelectric smoke 8.1.1 Interior Doors:Provide prehung, 1-3/8"pine doors. Doors shall have full'/a" detectors in each bedroom and at each level(two at corridors greater than 10'-0" by DIVISION 15-MECHANICAL long)with battery backup(or as indicated on drawings,whichever is greater). jambsowner). Face panel to match existing raised or flat panel. V ,colonial stops and fully mortised hinges(hinge l.Vas selectederify panel style with Section 15-HVAC Connect units in tandem with each other. Detector units shall be a minimum of Owner prior to ordering. Hardware shall match existing. 3'-0"away from any bathroom door,HVAC supply grille,and HVAC return 15.1.2 Extend existing heating and cooling systems into new work. Cut and patch grille. Units in bedrooms shall be no closer than 4"to any side-wall and no diffuser openings as required with like materials to complete the work. further than 3'-0"away from the bedroom door. If system requires greater than 8.1.2 Provide hardware allowances as follows: 12 devices, a low voltage system with a fire alarm panel must be installed. Low Per lockset,interior door $80 ¢�D ARC Per lockset exterior door $700 15.1.3 Materials:ductwork shall be constructed so as to conform to SMACNA. voltage system to be furnished and installed by owner. Submit cut sheets for cook P ITER 'S'/T alarm panel and all devices to building department for approval. 6� " 15.1.4 Run all new ductwork around perimeter of all crawl spaces,basements and attic ° s� 8.1.3 Pocket door hardware shall be 1750 series with ball bearing hardware and jamb areas(so as to maximize usable floor area). Verify proposed ductwork 16.1.16General Contractor shall furnish and install I IOV smoke/carbon monoxide kit as manufactured by A&F Wood Products,Inc. Hardware is available at Home De pot. locations with Architect prior to fabrication and installation. detectors within 10' or less of each bedroom and one at each level with battery P backup(or as indicated on drawings,whichever is greater).Connect units in 15.1.5 All H.V.A.C.duct tape for both rigid and flexible duct work sealing shall be 2'/z" tandem with each other Detector units shall be a minimum of 3'-0"away from wide Nashua 324A conforming to U.L.181A-P(Nashua 800.248.7659)no or any bathroom door,IIVAC supply grille,and IIVAC return grille.If system �27t� DIVISION 9-FINISHES requires greater than 12 devices, a low voltage system with a fire alarm panel �TF v�y O F NF 7 9 11 13 47 r 0 S W OA ) I n o S 0 _.._J �`-� Y T 2 S8U L_J L 1_J A03SA 9 9 DATE 08/29/2023 PRo1ECr 110 2 3 0 1 4 SHEET 2 OF 3 moasHI NOTCH 2.OE G-P LAM LV.L(S) AND STEEL PLATE(S) AS REQUIRED FOR STAGGER 6' STAGGER @ ROOF RAFTERS (1/3 TOTAL DEPTH 1/3 1/3 L 1/3 12" 16' O.C. 16" O.C. 1 12" 6 1/4- FURRING STRIPS ATTACHED DIRECTLY 11 r—MAX 2' DIA. V/` MAX. MAX. MAX.) MAX. MAX. TO EACH STUD TO ALLOW SPACE TO RUN RUBBER MEMBRANE INSTALL NEW WONDERBOARD TO ALL AREAS TO BE TILED. (SEE SPEC FOR FURTHER HEAD HEIGHT MEASURED = INFORMATION) 2X DIA. OF LARGER HOLE FROM FINISHED FLR. TO UNDERSIDE OF FRAME MISC. NON CONTINUOUS 2X BLOCKING 0 6 M RUBBER MEMBRANE NOT TO HAVE ANY C.D FASTENING PENETRATIONS PIERCING THROUGH V) MICROLLAM LVL PARALLAM PSL BEAMS FIRST 12" ABOVE FINISHED FLOOR. FASTEN MIN. BEARING AT 1/2- DIA. STEEL NUT, BOLT, & REFER TO BEAM MANUFACTURERS LITERATURE FOR FURTHER INFORMATION. 01 AT TOP OF BLOCKING EACH SUPPORT TO WASHER AT EACH SIDE CONTACT ENGINEER FOR HOLES EXCEEDING 2" DIA. INSTALL NEW RUBBER MEMBRANE TIGHT TO KLESSE FORBES ARCHITECTS BE (2) 2 x 4's ASSEMBLY. HOLE NOT TO WINDOW <) EXCEED DIA. OF BOLT. (TYP.). 1/3 1 1/3 1 1/3 CORNERS (INSTALL AS PER MANUFACTURERS 38 CHATHAM ROAD INSTALLATION REQUIREMENTS) SHORT HILLS, NEW JERSEY 07078 TYPICAL BEAM BOLTING LAYOUT NEW TILE FLOOR TO BE INSTALLED OVER I PHONE (973) 379-6602 1/4" MUDBED W1 RUBBER MEMBRANE OVER KLESSE.COM SCALE: 3/4" 1'-0" SLOPED CEMENT SUBFLOOR TIMOTHY P. KLESSE, AIA, ASID GIRDER 7 SEE NOTE FOR MAX. DIA. 2 X D1 Di SEE PLAN SEE PLAN t JOIST T NJ 09204 NY 027863 0 a a 0 1 IMUM MINIMUM PER I—JOISTS 1/8' 1'-01 /8" PER V-0' ROBERT W. FORBES, AIA, LEED AP REFER TO JOISTS MANUFACTURERS LITERATURE FOR FURTHER INFORMATION. f -4 1 0 0 0 HEAD HEIGHT MEASURED NJ 21AI01962600 _T _771 _N1 FROM FINISHED FLR. TO U 6" 6' MAX. VERTICAL OFFS UNDERSIDE OF FRAME 0 MAX DIA 1/3 DEPTH OF JOIST tC L_R rCLTR� INTERIOR ALTERATIONS TO RESIDENCE OF: (2) 3/8" THK. x 1/2" LESS THAN GIRDER DEPTH x 1'-6" LONG (ONE ON EACH SIDE AND CENTERED IN ALL DIRECTIONS) STEEL PLATES W1 (6) 3/8' Mr. Hettich & Mrs. Moraski DIA. BOLT, WASHER, & NUT ASSEMBLIES (A307) 1 3/8' FROM EACH SIDE ON ALL CORNERS AND AS INDICATED. THIS ASSEMBLY OCCURS AT EVERY JOIST 825 Cedar Drive AND GIRDER CUT THROUGH WITH ANY PIPE GREATER THAN 2" BUT UP TO 3" IN DIA. WITH HOLE DIAMETER EQUAL TO 1/2' PLUS PIPE DIAMETER CENTERED DOOR NEW FLOOR DRAIN W/ FLUSH Southold, NY 11971 IN EACH STEEL PLATE, ANY BEAM LESS THAN 11 7/8- IN DEPTH AND ANY CONVENTIONAL FRAMING *04 GRATE TOP (SEE PLAN FOR MORE HOLE LARGER THAN SPECIFIED MUST BE SPECIFICALLY ENGINEERED. INFO) LIGHTING LEGEND CROSS HATCH REPRESENTS AREA WHERE PENETRATION MAY OCCUR FLOOR STRUCTURE (SEE PLAN FOR MORE INFO.) --- TYPICAL MIIIr.'ROLLAM LVL & PARALLAM PSL GENERAL NOTES: INSTALL BLOCKING AROUND PERIMETER AS REO. TO 0 1 4* LIGHTOLIER LYTECASTER LED L4R DOWNLIGHT (WET) ALLOW FOR NEGATIVE PITCH TOWARDS DRAIN. PENETRATION GUSSET DETAIL VERTICAL SECTION FOR TYPICAL HOLD DIMENSIONS JOIST PENETRATION LOCATION DETAIL DETAIL APPLIES TO UNIFORM LOADS ONLY, SHOWER PAN DETAIL APPLY RUBBER MEMBRANE TO PITCHED SUBFLOOR 650 LUMENS 90 CRI , 3000K, OPEN DOWNLIGHT, WHITE 2 3 SCALE: N.T.S. (4 L CONSULT ARCHITECT AND STRUCTURAL 5 PRIOR TO MUDBED AND FINISHED FLOOR. 0 2 5" LIGHTOLIER LYTECASTER LED L5R DOWNLIGHT (WET) SCALE: 3/4" 1'-0' NOTE: THIS DETAIL APPLIES TO ENTIRE SCOPE OF PROJECT. ALL HOLES AS NOT TO SCALE ENGINEER FOR ALL OTHER CONDITIONS. SCALE: 1 1/2" V-0- SPECIFIED ABOVE SHALL RECEIVE GUSSETING AS INDICATED ABOVE. 1000 LUMENS , 90 CRI , 3000K, OPEN DOWNLIGHT, WHITE 3 4' UGHTOLIER LYTECASTER LED L4RADJ DOWNLIGHT 650 LUMENS 90 CRI . 3000K, OPEN DOWNLIGHT, WHITE 2-5/8" X 1-5/8' WHITE OAK 4 5" LIGHTOUER LYFECASTER LED L5RADJ DOWNLIGHT SMALL CONTEMPORARY RAIL AS 1000 LUMENS , 90 CRI , 3000K, OPEN DOWNUGHT, WHITE MANUFACTURED BY CAROLINA STAIR FUTURE OUTDOOR SHOWER. PROVIDE DRAIN THROUGH 135 4' LIGHTOLIER LYTECASTER LED L4S DOWNLIGHT (WET) SUPPLY, WWW.CAROLINASTAIR.COM REMOVE EXISTING WALL FINISHED READY DECKING. PROVIDE SHOWER HEAD WITH A DRAIN AT EXISTING POST TO REMAIN (TYP. OF 2) 650 LUMENS 90 CRI , 3000K, OPEN DOWNLIGHT, WHITE VERIFY WITH OWNER PRIOR TO FOR GYPSUM BOARD AS INDICATED LOWEST POINT POSSIBLE. 13 ORDERING 6 5' LIGHTOLIER LYTECASTER LED L5S DOWNLIGHT (WET) REMOVE EXISTING CARPET AND PADDING PROVIDE 8" x 8' CEILING GRILL AND TRANSFER DUCT 1000 LUMENS , 90 CRI , 3000K, OPEN DOWNLIGHT, WHITE COMPLETE. REMOVE ALL NAILSTRIPS 4'-0" FOR COMBUSTION AIR ALONG W1 (2) 6- X 12- BACK 7 WALL FIXTURE (FURNISHED B.O.) HANDRAIL DETAIL AND FILL HOLES. FLASH PATCH FLOOR TO BACK RETURN GRILLS 6" ABOVE WD. BASE 0 CFLUSH AND LEVEL READY FOR NEW 13 8 DECORATIVE FIXTURE (FURNISHED B.O. NOT TO SCALE FLOORING AS INDICATED. 9 NUTONE QTXEN110S (FAN) SET WALL AS TO ALLOW CLEARANCE OF EXISTING SEPTIC 10 CALCULITE LED 3" EVOLUTION BY LIGHTOLIER CO-ORDINATE RECEPTACLE AND ALL II, LINE LIGHT ENGINE: C3LO85AO127K9NF TRIM:C3LAWHW ASSOCIATED WIRING HEIGHTS IN FIELD WITH OWNER. OWNER TO FURNISH 12 JUNG PRO-LED UPL30-WH (CLOSET LIGHT) AND INSTALL FLAT-PANEL T.V. AND 6'-0" SLIDER 13 PULL CHAIN FIXTURE WALL MOUNTED BRACKET. S=2'-10" : H=6'-8" VERIFY HAND WITH OWNER S=2'-10" WASHING MACHINE VALVE WITH BRONZE BODY, --- 14 CONTINUOUS LED TAPE LIGHT, 90 CRI, 3000K G.C. TO DEMOLISH EXISTING ACOUSTIC TILE CEILING AND i: DN IR H=6'-E" SINGLE LEVER WHICH CONTROLS HOT & COLD 11:7 FRAMING AND INSTALL 1/2" GYP. BOARD CLG. BOXING PINE SILL PINE SI WATER SIMULTANEOUSLY. PROVIDE RECESSED 15 LOW-VOLTAGE LIGHT COPPERMOON CM.830 WITH MISC. lx FRAMING AROUND ALL EXPOSED DUCT DRYER VENT BOX, VENT BOX SHALL BE ANTIQUE BRASS FINISH (800-727-5483) db CA WORK AND PIPING WHERE FINISHED BASEMENT AREA CO INSTALLED AT +/- 2'-6" A.F.F. AS TO BE C3 16 LOW-VOLTAGE LIGHT COPPERMOON CM.865 CONCEALED BELOW COUNTERTOP. PROVIDE SHUT OCCURS.(TYP. OF ENTIRE FINISHED BASEMENT) 90 g I -ib ANTIQUE BRASS FINISH (800-727-5483) 0 .- C�C=) OFF FOR HOT AND COLD WATER IN CABINET. Uj EXISTING LALLY COLUMN (TYP. OF 2) '..2 2 2 2 ci V r-=,7 4' LED STRIP LIGHT UP 113R P_7_>7 C 18 HEATH ZENITH 240-DEGREE OUTDOOR S.D./C.O. U LA NDRY,NV.,-,=L MOTION-SENSING SECURITY LIGHT < i 2 BAS -----------1, LU LEGEND OF CONSTRUCTION ACOUS"TIC' L ILG, CARPET I 1-1/4' PRIMED BALUSTER 0 2 2 -.2 0125-P-36 CONTEMPORARY, PLAIN BALUSTER BY CAROLINA STAIR 1/2" THK. MOISTURE RESISTANT GYP. BD. EXIST. PARTITION TO REMAIN M SUPPLY, WWW.CAROLINASTAIR.COM OVER 7/8" DRYWALL CHANNEL MECHANICALLY A ------- EXIST. PARTITION TO BE REMOVED FASTENED TO WALL AS REQUIRED. USE DETAIL ±5' 8" 8/- WHERE APPLICABLE. -------- NEW PARTITION VERIFY WITH OWNER PRIOR TO --------- iT RELOCPTE NEW 2 x 6 PARTITION ORDERING .. ...... E. RETURN (BELOW) DEHUMIDIFIER FURNISHED BY --------- 0 < NEW RAILING AND OWNER AND INSTALLED BY G.C. MATH 'A'1 5'-7" 'A' 2 C-1) INFILL WALL U Z NEW 42" HIGH PARTITION <3 2� BALUSTER. SEE DETAIL - --------- ul RELOCATE -------------- >< 6 DRAIN INTO SINK TRAP W/ WITH ±2'-6" \T & 7/- NEW INTERIOR BEARING PARTITION DISHWASHER DRAINAGE LINE. T ---------- ---- ------- MMM= BRICK / STONE PROVIDE POWER AS REQUIRED E. ASSUMED GIRDER PROVIDE SOLID AR ±2'-4" 127 4 x 4 POST _17 DROPPED ABOVE) I—BLOCEING AS 2 - 2 j 4 x 6 POST 01__- BALUSTER DETAIL i�n '-, ...... .. ZD REQUIRED 1P 6 JA 7 1 IN i 13 0 POST ABOVEJ SCALE: NTS H SADDLE �0 Q�....... 12'' 24" 24" 24" ARCHED OPENING 36" U C WINE, --HEAD E-1-HATOR-4-----4­ MECHANICAL RM 2'-0' F. BEDROOM #1 ROOM NAME _j 8 2 I 'AFF 13 042 00 OMATED 20A 42 FLOOR/PLUMBING (SEE SPEC.) I CIO illn. 0 t.n C) -0 EXISTING POST TO REMAIN CEILING/WALL HEIGHT A _�36" P U V2-6- SHELVING B.O. =3 a CEILING/WALL HEIGHT 0 POINT C 6 BEAM CONFIGURATIONS: - FLUSH RECESSED SEMI-RECESSED DROPPED lb 3 13 CK-3 6 .... ........ CLEARANCE --------------—-------- ------------------ --------- --------—----- L3 ..... 1/2- GYP. BD. SEE PLAN. W U-) METAL TOP TRACK All structure as indicated an plans is for floor 5/4" X WALL CAP or Tbove 3/4' THICK PLYWOOD FIRESTOPPING AS W/ EASED EDGES INDICATED AND IFIRESTOPPING AT 10' L E. WELL EQUIPMENT SEWAGE EJECTOR, PROVIDE This document: and the ideas and designs incorporated herein, PLUMBING AND ELECTRICAL 13 TO MATCH RAIL as an instrument of professional service, is the property of VERTICAL INTERVALS AS REQUIRED BY CODE. .0 AND BALUSTER Klesse Associates P.A. and is not to be used in whole or in part E. SPRINKLER SERVICES AS REQUIRED. without the written authorization of Klesse Associates P.A. PAINT WALLS WITH THEROSEAL WATER—PROOFINGI. — MEMBRANE PAINT E OIL TANK 3 5/8 METAL STUD WALL @ 16" O.C., NO. REVISION DATE R-15 BATT INSULATION) W/ 1/2- DEMO EXISTING BASEMENT FINISHED IN THIS AREA READY MOISTURE RESISTANT GYP.BD. INTERIOR SET 1 1/2- GAP FOR PAINT AT 1 1/2" ABOVE SLAB. DRAWI[NG TITLE DETAILS & METAL BOTTOM TRACK FOUNDATION / BASEMENT PLAN 1 1/2' x 1/2" ACTUAL WOOD BLOCKING RAISED 1/2" ABOVE EXISTING SLAB. IF THIS LINE MEASURES 3" DRAWING IS AT LL SCALE IN IF THIS LINE MEASURES 1-1/2- DRAWING IS AT 1/2 SCALE BASE AS SPECIFIED IN GENERAL NOTES INTERIOR ELEVATION SEAL CONCRETE FLOOR WITH BEHR CONCRETE & A) SC DATE: GARAGE FLOOR PAINT 1-PART EPDXY ACRYLIC IN :LE: 1/2" 1'-0" 08/20/2023 D C FOUNDATION BASEMENT PLAN SLATE i'3RAY P ETER SCALE: 61- 'A ' 0 0 SEE PLAN FOR FLOOR FINISH 1�4- = V-0- S I& GRAPHIC S A ------- ---------------- DRAWN BY: AF CHECKED Y. 027B TK nip:: t,',i 0 DRAWING NUMBER 4 rn (IYSIC M"M I W/ �'l PER 14'-1' (U-J, T C2 8 BASEMENT FINISH DETAIL-METAL A® 1 SCALE: 3/4" = 1'-0" PROJECT No23014 SHEET 3 OF 3 MORASKI RHEEM SALES COMPANY, INC, Acondicionador de Aire Central Modelo:RA13NZ24AJlNA Tension Nominal: -208/230 V F '. 1 Frecuenciaia: 60 � Corriente Nominal: Hz 16/16 A Requi ar•a Tierra Fi si ca Leer aNaA►de3IADOaci6N Ope aibn Anexo 92'22050 t0-01 Antes de toner acceso a los idisposbos terminales,todos ios circubs de alimentawn deben ser interrumpidos. low Irb01L �•' 'Ullltl h•gA13N St11lAL M0.! Z2 M. 1AJiNA E 'RLSSOR Ol SERI( MI12)I0322 MfD. Tnt i 5 / CODES DE UTI,ISi.•311T"W'i JSi: C RESS(NI/ C R23O C RESSEUR 10k Ek 11i41ki;w am OUtt)OOR F ESSEIR ►MASS, 1 9811/9839 EUR AMIE7RIT, F.LR.I.A. 11.5/i1.5 L RE,A?ZSP.50 �? VENTII. MIN• SUPPLY CIRCUIT AMPACITY/ A(B�) A. 0. COURANT ADMISSARLE 0' M'1'• 1/@ MAX. FUSE AL1M, MIN. 16I16 CAI.. R CKT. BXR. SIZE./ A M1, MAX.MAx Dk FUSIBLE/DISJ•FUSE OR CKT, 25/25 ;CAL. MIN, BRK. SIZE-/ A ■ DES: OE FUSIBLE/DISJ. PRESSI PRESSURE H1GN/ 20/20 NOMINALE A r� DESIGN PRESSU HAUTE 450 p SIGN RE LO4/ SIG/3102 kva PRESS NOMINALE SSE ]U'p00R UR ITS FACTOR`1 250 PSIG/17Z3 kPa CHARGE USINE D'UN:T CHARGE/ TO AL SYSTEM CHAR. S EKTERIEUR 78 02/2211g Ra10A CHARGE TOTALS OD SYSTEMS INIOq SEI A OR, LAC:KST PANY 5 0.1510E ACCESS F1WR P SALES Ca KTj C'IKTEAIEM OU pA A�VAG( �^ Q FORt SMITR• ARKANSAS •MN,.P IT;H tFEAKEI V OI SJ m'CV.DlEEACNI IEL.�.: AsslwE[o • ,. a 61N6LE PJI.E CUNn AECTCMi61 � CE fA- _ �NYwCTEC1A6 UNI ��cyae NAZAtDOUS VOt1AOf - �