Loading...
HomeMy WebLinkAbout48758-Z SUFFO(o` Town of Southold 11/1/2023 y� P.O.Box 1179 0 53095 Main Rd y�jo ao� j Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44705 Date: 11/1/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 600 E Legion Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 143.4-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/9/2022 pursuant to which Building Permit No. 48758 dated 1/19/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Hart,Michael&Lauren of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48758 10/30/2023 PLUMBERS CERTIFICATION DATED Auihotized Usgnature °�SUFFnt,t�. TOWN OF SOUTHOLD BUILDING DEPARTMENT H x TOWN CLERK'S OFFICE "o • + SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48758 Date: 1/19/2023 Permission is hereby granted to: Hart, Michael 4705 Center Blvd Apt 507 Long Island City, NY 11109 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 600 E Legion Ave, Mattituck SCTM #473889 Sec/Block/Lot# 143.4-11 Pursuant to application dated 12/9/2022 and approved by the Building Inspector. To expire on 7/20/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector pF SO!/ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY ]1971-0959 �� �� Jamesh )-southoldtownny.gov �yCDUNT`I,N BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mike Hart Address: 600 E Legion Ave. city:Mattituck st: New York zip: 11952 Building Permit#: 48758 Section: 143 Block: 4 Lot: 11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: Element Energy LLC Electrician: Jamie Minnick License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200a Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200a A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency StrobeHeat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 6kw roof mounted solar energy system with 15 panels 15 qcell q peak duo bik ml-g10+ 400 watt pv moudules, 15 micro inverters, 1 enphase iq combiner pa Notes: SOLAR SYSTEM Inspector Signature: Date: October 30, 2023 600 a legion ave SOUTH°lo # # TOWN OF SOUTHOLD BUILDING DEPT. MuNr+, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [,j"�FINALn- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE 10',5a-a3 INSPECTOR �aOFOS Glyn_ V 7 5 ,b er, GFG"T 0,U Aue, # TOWN OF SOUTHOLD BUILDING DEPT. coum, 631-765-1802 'INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: So f 0.< i ' 40+ (,0 fit, otd u . 0,�,L,o AM15, k9LOCA OVI kkktk5 DATE �� 3� INSPECTOR LUIGI CLAUDIO SCIANDRA, P.E. 5 Wesleyan Court• Smithtown, NY 11787-3011 (631)543-2953•fax(631)543-1526 Cell.631-747-7495 E-mail:Ics4dOaol.com Sunday, April 02, 2023 - Town of Southold JUN 7 2023 53095 Route 25 P.O. Box 1179 Southold, New York 11971 ' Re: Certification Letter- Fifteen (15)400 W PV Roof Top Solar Panels, 6.0 kW DC Total Output,for Hart Residence, 600 East Legion Avenue, Mattituck, New York 11952 I have reviewed the solar energy system installation in the subject topic on 03/15/2023. The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department of the Town of Southold. The solar panel installation is in compliance with the requirements of the 2020 Residential Code of New York State, SEI/ASCE 7-16 "Minimum Design Loads for Buildings and Other Structures!% 2017 NEPA Standard 70"National Electrical Code", markings in accordance with Section 690.53 of the National Electrical Code are provided. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes and standards applicable at the time of submission, conforms with reasonable standards of practice with the view to the safeguarding of life, health, property and public welfare. Sincerely, OF NEW YO 5 C.SCIgNQ �25�0 060935- AROFESSIONP� Luigi Claudio Sciandra, Professional Engineer. ELD INSPECTION REPORT DATE COMMENTS �r Z FOUNDATION (1ST) ----------------------------------- -- O C, FOUNDATION (2ND) ROUGH FRAMING& PLUMBING -- r r INSULATION PER N. Y. STATE ENERGY CODE --- - C� FINAL ADDITIONAL COMMENTS -- 0 ..23 - _ ale c, cd �® idument ID:2A768FFA-KKBW4MHJXFVZFUIWANB99D69DO8UOVXAST6NKH5UVJW J TOWN OF SOUTHOLD —BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowmy._oovv Date Received APPLICATION FOR BUILDING PERMIT or Office Use Only d PERMIT NO. BuildingInspector: A P DEC 9 2022 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an TULDRIM DEV- 11". Owner's Authorization form(Page 2)shall be completed. TGVN tq.;S0?;T.€ 0LD Date: OWNER(S)OF PROPERTY: ' Mike Hart �Mi000- Name: Project Address: 600 E Legion Ave, Mattituck, NY 11952 Phone#: 908-507-3664 Email: Mailing Address: CONTACT PERSON: Name: Charles Jacabacci Mailing Address: 7470 Sound Ave., Mattituck, NY 11952 Phone#: 631-388-7041 TEmail: charies.jacabacci@e2sys.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Element Energy LLC Mailing Address: 7470 Sound Ave., Mattituck,NY 11952 Phone#: 631-779-7993 Email: permits@e2sys.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ✓Other 6 $ 29,787.00 Will the lot be re-graded? ❑Yes ✓No Will excess fill be removed from premises? ❑Yes ✓ No 1 Zoho Sign Document ID:2A768FFA-KKBW4MHJXFVZFUlQANB99D69DO8UOVXAST6NKH5uVJW PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Residential Zone AC this property? ❑Yes ✓No IF YES, PROVIDE A COPY. I-V-Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,Newyork and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. N1lt4-�Lkw-rcl.-1 Application Submitted By(print name): Ghefleejaeahassi ✓Authorized Agent ❑Owner Signature of Applicant: Date: Dec 06 2022 CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State of New York No.01 B U 6185050 SS: Qualified in Suffolk County COUNTY OF Suffolk ) Commission Expires April 14,2 0a14 Charles Jacabacci t ing duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor/Agent (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/heC=gtLVgpAvqlyl belief; and that the work will be performed in the manner set forth in the application file there r fl!y Public,State of New York No.01 806314813 Qualified in Suffolk County Sworn before me this Commission Expires November 17.202G 7 day of ®G , 20 zr-- otary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, Mike Hart residing at 600 E Legion Ave,Mattituck,NY 11952 do hereby authorize Element Energy LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. Mlle- �'(° Mlle- Dec 06 2022 Owner's Signature Date Mike Hart Print Owner's Name 2 Zoho Sign Document ID:2A768FFA-KKBW4MHJXFVZFUlUANB99D69D08UOVXAST6NKH5QVJW .y ef�'f"%if pj�:�®� BUILDING DEPARTMENT- Electrical Inspector Q G * TOWN OF SOUTHOLD {co z Town Hall Annex- 54375 Main Road - PO Box 1179 s a, Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr fsoutholdtownny.gov seandCc southoldtownny.caov . APP:LICi"TI,ON FOR ELECTRICAL INSPECTION. ELECTRICIAN INFORMATION (All Information Required) Date: Dec 06 2023 Company Name: Element Energy LLC Name: Jamie Minnick License No.: 52689-ME email: permits@e2sys.com Address: 7470 Sound Ave.,Mattituck,NY 11952 Phone No.: 631-861-5920 JOB SITE INFORMATION (All Information Required) Name: Mike Hart Address: 600 E Legion Ave,Mattituck,NY 11952 Cross Street: Phone No.: _9.08-507-3664 Bldg.Permit#: _ LIE ISE email: Tax Map District: 1000 _Section: 143,00_. _- - ., ._ BIOCk:. 04,00_ Lot: 011 BRIEF DESCRIPTION OF WORK (Please Print Clearly) .roof mounted solar PV system with 15 enphase-micro inverters and 15 QCELL modules Circle All That Apply: Is job ready for inspection?: ✓ / NO Rough In Final Do you need a Temp Certificate?: NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _- _A #Meters Old Meter# . - New Service- Fire Reconnect- Flood Reconnect-Service Reconnected- Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: .PAYMENT.DUE-WITH APPLICATION Request for Inspection FormAs NYSI F New York State Insurance Fund PO Box 66699,Albany,NY 12206 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 95991 07/13/2022 TO 07/13/2023 7/19/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE SUR NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 126776733 U-26.3 NEW workers' CERTIFICATE OF INSURANCE COVERAGE STAE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1 a. Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK, NY 11952 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured (Only required if coverage is specifically limited to certain locations in New York State,i.e., Wrap-Up Policy) 823336604 2. Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"1 a" SOUTHOLD, NY 11971 DBL567527 3c.Policy effective period 01/01/2022 to 12/31/2023 4. Policy provides the following benefits: R1 A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/20/2022 By (WV/ Ut (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board (only if Box 413,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 111111111 !�°�!°°°°1°1°°°°°1°11°1°°1111111 oma® CERTIFICATE OF LIABILITY INSURANCE DATE(MM7,21/20�2 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERTS. FEDE INSURANCE AGENCY PHONE - - FAX631-385-1766 23 GREEN STREET,SUITE 102 E-MAIL vc No HUNTINGTON, NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURER B:STATE INSURANCE FUND 523930 Element Energy LLC INSURERC:SHELTER POINT POINT _8T4—,T4_ ELEMENT ENERGY SYSTEMS INSURER D: GENERAL STAR MANAGEMENT CO. 7470 SOUND AVENUE INSURER E: MATTITUCK, NY 11952 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR rypE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR SD D POLICY NUMBER MM/DD/YYYY MMIDD/YYYY 7/14/2022 7/14/2023 AAMAGE TO COMMERCIAL GENERAL LIABILITY X X CL00275204 EACH OCCURRENCE $ 3,000,000 RENTED CLAIMS-MADE � OCCUR PREMISES(E.occurrence) ccurrence) $ 100,000 #D IMA389203A MED EXP(Any one person) $ 5000 X Contractual Lia 7/14/2022 7/14/2023 PERSONAL&ADV INJURY $ 3000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 3,000,000 POLICY 1 PES F-1LOC PRODUCTS-COMP/OP AGG $ 3000000 Y OTHER: $ AUTOMOBILE LIABILITY COMEaadBINEDnt SINGLE LIMIT $ ccie ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident F $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION 124494445 PER OTH- AND EMPLOYERS'LIABILITY Y/N 7/13/2022 7/13/2023 STATUTE ER ANY PROPRIETORIPARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 B OFFICER/MEMBER EXCLUDED? XI N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ 1 000000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1-000-non NY State DBL DBL567527 1/01/2022 1/01/2023 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 MAIN ROAD THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. SOUTHOLD, NY 11971 AUTHORIZED REPRESENTATIVE 2o3E2r s FEDE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD Od LuIGI CLAUDIO SCIANDRA, P.E. 5 Wesleyan Court- Smithtown, NY 11787-3011 - (631)543-2953-fax(631)543-1526 E-mail:lcs4d@aol.com ,---:> Tuesday, October 04, 2022 L= Element Energy Systems L 7470 Sound Avenue L9 Matfliuck, New York 11952 DEC 9 2022 Tel. 631-779-4004 Attn.: Mr. Mike Lawton, Principal D,71-P 7N"G DE P T TCYWI-q, Re: Fifteen_(I5)•400WO V Roof.Top Solar Panels.6.0 kW I DC Total Output,for Han Residence:600 East;Legion Avenue, Mattituck New York'11952' Dear Mr. Lawton: Pursuant to your request, I have reviewed the following information regarding the subject roof top solar panel array: • Cover Sheet with Site Visit/Verification prepared by E2Sys representative identifying specific site information including size and spacing of roof supporting element for the existing roof of the proposed system to include cover sheet, site plan, mounting and structural details. This information was prepared by E2Sys and will be utilized for approval by the Building Department of Town of Southold and for construction of the proposed system. Based on the above documentation, I have evaluated the structural capacity of the existing system to support the additional loads described below, imposed by the solar panel arrays and offer the following comments. The existing roof types are as follows: Solar Array#I: Single layer of asphalt shingles, 2"x6" at 16" on center Douglas Fir rafters, 2")6" at 16" on center Douglas Fir ceiling joists, Roof pitch: 300, 1"x8" tongue and groove. SttUbtura'l Analysis: The structural analysis has been carried out using the following design criteria: Design wind speed: 130 mph Ground snow load: 20 lbs/sq. ft. Solar Array#1, Dead Load: 2.7 lbs/sq. ft. Total Array#1 weight: 870.2 lbs The above values are within acceptable limits of recognized industry standards for similar structures.The structural analysis, performed for the existing structure and for the solar panel arrays, utilizing the above design loads, indicates that the existing roofs will be able to support the additional panel weight without damage, if installed correctly.The onsite inspection and the photographs show that the roof framing is in good conditions. However, the building owners are to be made aware that long term build up of heavy snow conditions may produce deflections in the roof structure. If any deflection is noticed, than it is recommended that the solar panels be cleared of accumulated snow more than one(1)foot deep over a period of one week. If no deflections are visible under any snow loading over a period of time,then there is no need to clear the solar panels. Based on the above evaluation, it is the opinion of the undersigned professional engineer,that with appropriate solar panel anchors being utilized,the roof system will adequately supportthe additional loading imposed by the solar panel arrays. This evaluation is in conformance with the 2020 Residential Code of New York State, SEI/ASCE 7-16 "Minimum Design Loads for Buildings and Other Structures", 2017 NFPA Standard 70"National Electrical Code",current industry standards and practice and based on documentation and data supplied by E2Sys at the time of this report. Should you have any questions regarding the above or if you require additional information, do not hesitate to contact me. Sincerely, r - 1" - �� OF NEW YO Cl 40 sFo esos35:'` �Q' �afiESSIQ��� Luigi Claudio Sciandra, P. E. 2 DE51GN 4 DRAFTING BY: ELEMENT ENERGY LLC 50LAK ARRAY ON MAIN HOUSE G.kW REVIEW 13Y J.M.NAI3CEP CERTIFIE (1 5)QCELL Q.PEAK DUO BLr,ML-G 10= 400 WATT PV MODULES 05 1 1 1 2-1 29 (1)STRING OF(1 O)MICRO-INVERTERS 4(1)5TRING OF(5)MICRO-INVERTERS '(2)STRINGS TOTAL TO UTILITY GRID REVISIONS DE5CR STRING #I - _ - - , = o�NALPr1oN 1 09-29-20221 REV 1 N ------------ -- I - - 51-DITRECTIONAL 1 UTILITY METER 1 ------------------ I-PHASE,240 V I MICRO-INVERTER 1 ENPHA5E 106PLU5-72-2-U'5 STRING #2 240 VAC, 1.21 A 97%CEC-WEIGHTED EFF. NEMA&UL L15TED TYPICAL �- -..., �-f, 1 N CONTRACTOR 1 - ------- ` P� c 1 ------ ---- -- ^^ qq NAIN SERVICE D15C0NUEC I s. - J,, Y 240 V.200 o ENPHA5E aRANcr °; ; I �� ELEMENT ENERGY, LLC. I C ROUIT CA5LE TYPICAL _ `tip Y ' 7470 SOUND AVE 2-POLE w arEarEP MATTITUCK, NY 1 1 95 -- sr EuI NPHASE IQ coMSER 4 240V,25A LICENSE# G74GI-til u 24C•!'.C.9C / '5 7' h3R u_vsED err' AsrneASPosseL mow, LICENSE# 52689-ME ?-1 �, MAN$ VIC`D15CONNEC7 1 -120 A D0J_'U Pot�:s� r�t�=.,fig ICT( LI G t1 I 'i - i± '�t''..C•e`''iL-i� . I 1 I_ 1 1 PROJECT NAME I I 25, MAIN SERVICE PANEL I I-PH.3-W G 2=A VAC N L1 ----------------------------- 20D A N W Ln I I I I I I EX15T1NG GROUNDING z j ELECTRODE 5Y5TEM W z -----------JQ O �-- I , _ z I I w CD LLj L-----------------------------------=- -------------- WIRE CONDUIT SCHEDULE Cz __j U L LU CIRCUIT CIRCU!T CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% < O 1.D. # ORIGIN DESTINATION SIZE PEP,POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AI) TYPE SIZE TEMP DEBATE DISTANCE Q F- 3 1 Ow!5,5X3) 310.1 50)(2a)0d = O �- I INVERTERS COMBINER PANEL AWG#126 0.8 U5E-2/PV Wire AV✓G#8 1 BARE CU FREE AIR !" 559C 0.84 1 10 FT 2.2% UQ OR EMT 2 COMBINER PANEL MAIN PANEL AWG 4 10 3 1 T, WN-2 AWG#8 ! THNN-2 Cu PVC I" 459C0.95 25 FT 0.6% ELECT RtCAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE L15TED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Ci,cu:t Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS 5HALL BE COPPER, RATED FOR 600 V AND 900-C WET ENVIRONMENT. [NEC G90.8(B)(I)j: (Isc)'(#or-5trinos)'(1.5G= `5.13 A 3-LINE DIA. 3.)WIRING. CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS 5HALL BE ROUTED DIRECTLY Modules per String I O MAX. TO,AND LOCATED AS CLOSE AS P05515LE TO THE NEAREST RIDGE. HIP,.OR VALLEY. AWG#!2; am .1 3 'Temp berate = e 16 A 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 20.I v r > I ut 13 A,therefore y C lcul s¢e Is valid. Modules per Inverter I COMPLY WITH NEC I i 0.26. #.2 Inverter Output Wire Ampaclty Calculation Number of Inverters 15 F Inverter Max Amperage output' (1.25) = 22.F.9 A Record low tem I 0°C 5.)DRAWINGS INDICATE THE GENERAL ARRAN'G�MCNT Of 5Y5TEM5. CONTRACTOR 511ALL AWG#10,ampaclty'(Temc Derate)'(Condult Fill Derate) =38 A p FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACE550PIf5 TO FULFILL Voc Temp Coefficient -0.24%/--C DRAWING 5CALE APPLICABLE CODES AND STANDARDS. 38 A> 22-GO A.therefore AC wire 512e 15 valid. DC in STEM SPECIFICATIONS 6.)0/HERE SIZES OF JUNCTION'BOXE5. RACEWAYS,AND CONDUITS ARE NOT SPECIFIED. THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Operating,Current 10.8 A N .T.5. 7.)ALL WIRE TERMINATIONS 5HALL BE APPROPRIATELY LABELED AND READILY VISIBLE. Operatinq Voltage 37.1 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Max.System Voltage 49.G V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. Short Circuit Current 13.9 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEER LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR ILSGO G5L-4DBT LAY-IN LUG. Max Output Current 22.69 A 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(posltwe/negax ative) - p\ /- OR O eratin AC Volta e 240 V I V 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND 511ALL COMPLY WITH NEC 690.35. TAX MAP: 1000- 143.00-04.00-01 1 .000 CONSTRUCTION SUMMARY- MAIN HOUSE (15) QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULES DESIGN E DRAFTING BY: (DIMENSIONS: 74"X 4 1.1"X 1.3") ELEMENT ENERGY LLC (1 5) ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS REVIEW BY J.M.NADGEP CERTIFIE (28)ATTACHMENT POINTS @ 72"O.C. MAX. p° 0511 12-120 (129.7) LF IRONRIDGE XR 100 MOUNTING SYSTEM. , ROOF TWREVISIONS E: ASPHALT SHINGLE(SINGLE LAYER) w2�p° 4 DESCRIPTION DATE REV CONSTRUCTION NOTES 24p° ORIGINAL os-z9-zozz' 9p° 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE ?gyp° �2p° F WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 78p°�Sp° 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. s 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. NOTE 1.)THE ROOF SETBACWATHWAY SHALL NOT BE O CONTRACTOR REQUIRED TO DETACHED GARAGE IN ACCORDANCE WITH 8324.6 EXCEPTION OF O 2020 NY5 FIRE CODE 2.)THE ROOF SETBACK/PATHWAY SHALL NOT BE ELEMENT ENERGY, LLC. REQUIRED TO ROOFS WITH SLOPES OF TWO 7470 50UND AVE UNITS VERTICAL IN 12 UNIT5 HORIZONTAL OR MATTITUCK, NY 1 195 LE55 IN ACCORDANCE WITH R324.G.I LICENSE# G74G I-HI EXCEPTION OF 2020 NY5 FIRE CODE LICENSE# 52@89-ME PROJECT NAME Ln CV U > wz - � 0z LLJ LU LuU QOF= = � Q ACCE55 ROOF LEGEND � SRVI PMETER � ®NEW PV SUB—PELS =DISCONNECT. SINER INVERTERS ARRAY-#-I i SHEET NAME GND ELECTRODE 15'FNI�DULES_.; �'-PlTCf�S-'`p�-� �.. Az"��T� ®PV MODULE RACKING RAIL ROOF D ETA� eat �.�o 0 ATTACHMENT POINT ---RAFTERS —ROOF PITCH ANGLE 3G°x 36°GROUND ACCE55 TYP, DRAWING SCALE 19SUNRUN METER vIII II = I I—OII ®VENT 1/5 2 0PLUMBING VENT ®SKY LIGHT ®CHIMNEY I SHEET NUMBER ®COMPOSITE MINGLES TENTIAL SHADING ISSUES P\/ GOOD CONDITION 4 I V —3 ❑TRIMAEMOVE AS NECESSARY TAX MAP: 1000-143.00-04.00-01 1 .000 LOAD CALCULATION ARRAY#I ITEM DE5GPIPTION ARRAY#I DE51GN 4 DRAFTING BY: RB Ridele,Beam/Board 2"X 8" D. FIR ELEMENT ENERGY LLC R Roof Rafter 2"X G" D. FIR I G" 0.C. REVIEW BY J.M.NABCEP CERTIFIE MODULE WEIGHT(Lbs) 48.4 051 1 12-129 (D) Deckln I"X 8"TONGUE GROOVE #OF MODULES 15 (J} CeiIin 'Joist 2"X 6"D. FIR !6"O.C. (P) Pitch 309 KEV1510N5 TOTAL MODULE WEIGHT(Lbs) 726,0 DESCRIPTION DATE REV (h} florizontal Span of(R 93"MAX. TOTAL LENGTH OF RAIL(Ft) 129.7 ORIGINAL o9-29-2022 RAIL WEIGHT PER FOOT(lbs) O.G8 TOTAL RAIL WEIGHT(Lbs) 88.2 #OF 5TRANDOFF5 28 - T - WEIGHT PER 5TRANDOFF(Lbs) 2 i':' .' r '•, (D) TOTAL STANDOFF WEIGHT(Lbs) 56 TOTAL ARRAY WEIGHT(Lbs) 870.2 POINT LOAD(Lbs) 31.t CONTRACTOR TOTAL ARRAY AREA(5q Ft) 321.2 ARRAY DEAD LOAD(Lbs/5a Ft) 2.7 ELEMENT ENERGY, LLC. WIND DESIGN SUBJECT TODAMAGEFROM 7470 SOUND AVE I GROUND SEISMIC WINTER ICE BARRIER AIR MEAN SNOW d Special Windborne FLOOD MATTITUCK, NY 1 195 Speed Topographic DESIGN Forst DESIGN UNDERLAYMENT FREEZING ANNUAL LOAD* (mph) etfec sk wind debris CATEGORrf Weatherine tine Termite° TEMPe REQUIREDh HAZARDS9 INDExt TEMO ! LICENSE# 6746 I-HI i regiont zone' depthh i LICENSE# 52689-ME MUD lu 1 j 20 140 NO NO NO B SEVERE 3 FT HEAVY 15"F YES ZONE X 599 51"F I MANUAL)DESIGN CRITERIA° i Winter Summer Attitude Heating itude Design j (r1)- + Elevation Latitude design temperature heating cooling correction factor temperature cooling temperature difference ; PROJECT NAME (J) 108 FT 41'N 15'F 86"F 1.00 70"F 75"F 55'F !4 Cooling Wind Wind Coincident Daily Winter Summer tempera turedifference velocity velocity wet but range humidity humidity Ln heating cooling W 11"F 15 MPH 7.5 MPH 72-F MEDIUM(M) 40% _ 32 GR @50%RH U Q For St:1 and r square foot=0.0479 kPa,1 mile per hour=0.447 m/s. I 1 W z pound pe q P ROOF FRAMING DETAIL a- Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength O Z required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or'severe for concrete as determined (� from Figure R3012(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652- LIJ J b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1).the frost line depth strength required for weathering shall govem.The jurisdiction ' ` shall fill in the frost line depth column with the minimum depth of footing below finish grade. `.J C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. MODULE MOUNTING CLAMP W d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined O on a site-spec basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from 50LAK MODULE Q O 9 ry Pe -p Appendix D of the Plumbing Code of New York State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also 5TAINLE55 STEEL 3/8" Q see Figure R301.2(1).] BOLT AND NUT f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the �k Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: NRIDGE ALUMINUM RAIL i.The accompanying Flood Insurance Rate Map(FIRM), ii.Flood Boundary and Floodway Map(FBFM),and AWMINUM°L"BRACKET iii.Related supporting data along with any revisions thereto. 5HEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section- ALUMINUM FLA5HING h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) ST RU CT U RA value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32"F)." A5PHALT SHINGLE ROOF j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method (Base 32"F)." 5/1 6" 6 x ^STAINLESS k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 5/1 G" G' BOLT WITH2 I/2"MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION 5FALED DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) AS NOTE D m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. SHEET NUMBER (`) See Figure R301.2(4)B. _ PV-5 TAX MAP: 1000-143.00-04.00-01 1 .000 MOUNTING DETAIL n DE51GN 4 DRAFTING BY: SOLAR ARRAY ON MAIN HOUSE 6 kW ELEMENT ENERGY LLC ' (15)QCELL Q.PEAK DUO BLK ML-G 10+400 WATT PV MODULES REVIEW BY J.M.NABCEP CERTIFIE (1)STRING OF(10)MICRO-INVERTERS (1)STRING OF(5)MICRO-INVERTERS 051112-129 '(2)STRINGS TOTAL TO UTILITY GRID REVISIONS STRING #I DESCR PTION DATE P.EV ORIGINAL 09-29-2022 r- ------------------ --------------- -- 1 N - _ - 5 - 5 - I BI-DIRECTIONAL I UTILITY METER I �----� -----" -----� -----� �----' '----� I-PHASE,240 V I 1 1 N I I MICRO-INVERTER STRING #2 ENPHA5EIQ8PW5-72-2-U5 240 VAC, 1_.21 A - - - _ 97%CEC-WEIGHTED EFF. „r,..•^`�1- 1 - -- -- -- NEMA G.UL LISTED 1 TYPICAL 1 CONTRACTOR MAIN 55ZVICE DI5CONNECi V.200 A ELEMENT ENERGY, LLC. CIRCUIT CABLE TYPICALb' ' f +` I - `� 7470 SOUND AVE 1 MATTITUCK, NY 1 195 2-POLE PV BREAKER .:. Y 1=,�1PHASE IQ COM3INER 4 � �" 24o L',25 a `� � � LICENSE# 6746 1411 240 VAC, R.1i USTFD St AS 0.e A5'FossIBD`FP.OM t=12DaDa„w�PstsP_ax.Rs - ' ` (�1.�`i yc,1 "' KWN5ERVICEDI5CONN[CT LICENSE # 52689-ME 20, 2L I I I I I -J PROJECT NAME 1 25 A MAIN SERVICE PANEL I -PH.3-W G N LI I 240 VAC N N �on 200 A Lu In G W I I 1 EXI5TING GROUNDING z I I -----------D I ELECTRODE 5Y5TEM ]LJ z I I � z I ILUW ------------------------------------- -------------J WIRE CONDUIT SCHEDULE (Z _j U LLJ CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% LO I.D.# ORIGIN DESTINATION 512E PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE 51ZE TEMP DERATE DISTANCE Q O 310.150X3) 310.15(B)(2ay(3c) I INVERTERS COMBINER PANEL AWG#12 1 6 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I° 55eC 0.84 I I O FT 2.2% Q OR EMT 2 COMBINER PANEL MAIN PANEL AWG#10 1 3 I THWN-2 AWG#8 1 THWN-2 CU PVC I" 45QC 0.95 25 FT 0.6% ELECTRICAL NOTES 5HEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE L15TED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am aci Calculation 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 V AND 902C WET ENVIRONMENT. p tY CONFIGURATION 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY [NEC 690.8(B)(I)]: (Isc)'(#of strings)'(I.56)= 15.13 A Modules per String 10 MAX. 3-LINE DIA. TO,AND LOCATED AS CL05E AS POSSIBLE TO THE NEAREST RIDGE, HIP.OR VALLEY. AWG#12,ampacity'Temp Derate= 20.16 A 4.)WORMNG CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 20.16 A> 15.13 A,therefore DC wire size is valid. Modules per Inverter I COMPLY WITH NEC I 10.26. #2 Inverter Output Wire Ampacity Calculation Number of Inverters 15 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output'(1.25) = 22.69 A Record low temp -I OAC FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACE550RIE5 TO FULFILL AWG#10,ampacity'(femp Derate)'(Conduit Fill Derate)=38 A Voc Temp Coefficient 0.24%/¢C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 38 A> 22.69 A,therefore AC wire size is valid. 6.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, DC SYSTEM SPECIFICATIONS THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Operating Current 10.8 A I .T.�j. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. Operating Volta e 37.1 V 1 v I �/ 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Max.System Voltage 49.6 V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 13.9 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR IL9CO GBL-4DBT LAY-IN LUG. AC SYSTEM SPECIFICATIONS 5HEET NUMBER 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5itive/negative) Max AC Output Current 22.69 A PV-5 OR O eratin AC Volta e 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000- 143.00-04.00-01 1 .000 SERVICE METER O O INSTALLATION NOTE DESIGN N DRAFTING BY: ELEMENT ENERGY LLC ® O SOLAR PV SYSTEM PHOTOVOLTAIC $ PHOTOVOLTAICREVIEW BY J.M.NABCEP CERTIFIE I SOLAR BRFAICER ( I ) ALL LABEL SHALL BE INSTALLED I N 0511 12-129 EQUIPPED WITH - ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN REQU I REM ENTS. REV1510N5 ® DE5CRIP(ION DATE REV (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 09-29-2022 llX S,S--EM-VOLTAGE SOLAR AC LOAD CENTER- OUTSIDE DO NOT RELOCATE THIS ; REQUIRE FIELD VERIFICATION. l OVERCURWDEMCE A (3) LABELS, WARNING(5) AND MARKING O3TURN RARDSHUTDOWNSWITCHTO ' Q SHALL BE IN ACCORDANCE WITH NEC THE'OFF°POSITION TO SHUT DOWN 110.21 (5). I PV SYSTEM AND REDUCE SHOCK11WMINTHEAMY AC DISCONNECT �� POWER 70 "M I (4) THE MATERIAL USED FOR MARKING Il WEE F"°'MEML"TEDAB`RDIAM MUST BE WEATHER RESISTANT, IN dSCONNEGiS LOCJIIED AB SHOWN SOLAR AC LOAD CENTER- INSIDE O � COMPLIANCE WITH NEC 110.2 I (B)(3). CONTRACTOR wear j FM (5) THE PV SYSTEM CIRCUIT CONDUCTORS 5HALL BE LABELED INSTALLED IN ELEMENNT ENERGY, LLC. ER SUPPLY SOURCES TOII�LRATINGOFALL I7470 SOUND AVE OVERCURREHTDMCES,EXCLUDING- SOURCES:UTILITYGRID j f • COMPLIANCE WITH NEC 690.3 1 . i MATTITUCK, NY 1 195 MAIN SUPPLYOVERCURRENr AND PV SOLAR LICENSE# 67461-III DEVICE,SHALLNOT EXCEED ELECTRIC SYSTEM CONDUIT- INSIDE BUILDING YOFetl= LICENSE # 52G89-ME !ta l THIS SERVICE METER ®; PHOTOVOLTAIC SYSTEM IS ALSO SERVED BY A , PROJECT NAME ELECTRIC SHOCK HAZARD i PHOTOVOLTAIC SYSTEM r.r_ TERMINALS ON THE UNEAND COMBINER PANEL 1' •~ > A LOAD SIDES MAY BE ENERGIZED � DO NOT ADD LOADS •' �;'�`�� CONDUIT- OUTSIDE BUILDING IN THE OPENPosmoN n. 'i, LLJ Ln ® ; • . Lu DUAL POWER SUPPLY I Q ISOURCES:UTILITY GRID AND e I rr� Z PV SOLAR ELECTRIC SYSTEM'3 V MAIN SERVICE PANEL - OUTSIDE ACAUTIONSOLARCIRCUIT !� l 1 U O O O O _.00AUTIQN_-____; ® Q C) sauR ELECTRIC SYSTEM COM�CiID 1 = O Q Q MAIN SERVICE PANEL- INSIDE ®� 4CURRENT OWER SOURCE PUT CONNECTION® OOTRELOCATETHIS 5HEET NAME DEVICE LABELS AC DISCONNECT/BREAKER DRAWING SCALE OOO ® ® N .T.S. 5HEET NUMBER PV-6 TAX MAP: 1000-143.00-04.00-01 1 .000 SCOPE Of WORK DE51GN*DRAFTINGBY: :;-.;g• i`�,y,�.,. ..kyr;' ..��".i -. ,:.- ,-. ELEMENT ENERGY LLC TO INSTALL A 6 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE HART RE5IDENCE, REVIEW BY J.M.NABCEF CERTIFIE LOCATED AT GOO E LEGION AVE, MATTITUCK, NY 11952. ;_ 051112-129 Iv i THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. `� '`• „r� •_��":;,wY .{ REVISIONS r, DE5CRIPTION DATE REV SYSTEMRATING �` ' '- ':j ORIGINAL ,09-29-2022 su g� 1 G kW DC STC APPR IE Ari�+ N® ED 3 DATE. kkB.P.it U EQUIPMENT SUMMARY FEE: BY: 15 QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULE5 NOTIFY BUILDING DEPARTMENT AT 15 ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS 765-1802 8 AM TO 4 PIvi FOR THE I IRONRIDGE XR100 MOUNTING SYSTEM FOLLOWING INSPECTIONS: I �. corrTRAcroR SHEET INDEX 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE ^`PV-1 COVER s ELEMENT ENERGY, LLC. PV-2 SITE PLAN 2. ROUGH - FRAMING & PLUMBINGPROJECT LOCATION 7470 SOUND AVE PV-3 ROOF PV LAYOUT 3. INSULATION MATTITUCK, NY 1 195 PV-4 5TRUCTURAU DETAILS 5ECTION5 4. FINAL - CONSTRUCT!ON MUST LICENSE#6746 I-f11 PV-5 3-LINE ELECTRICAL DIAGRAM PV-6 LABELS BE COMPLETE FOR C.O. LICENSE# 52G89-ME ALL CONSTRUCTION SHALL MEET THE '^_'' —==: N GOVERNING CODES REQUIREMENTS OF THE CODES OF NEW "s' r = :� `' 0° 2017 NATIONAL ELECTRICAL CODE- YORK STATE. NOT RESPONSIBLE FOR 2020 RESIDENTIAL CODE OF NEW YORK STATE. DESIGN OR CONSTRUCTION ERRORS. 31, . p t' 2020 FIRE CODE OF NEW YORK STATE. PROJECT NAME A5CE 7-1 G AND NFPA-70. 1` i W 270°—:3 r--900 E UNDERWRITERS LABORATORIES(UL)STANDARDS ` ? .., . 05HA 29 CFR 1910.269 ; 240° V 120° �y GENERAL NOTES - Ad rgs-,%, ' 210° 1500 w In .- �. 180° . Lu 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT - "> V W° Z — THE 51TE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE •' W Z Q HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK AERIAL VIEW w U z AGREE THE SAME. LL 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES Of RK PERFONCY,RMED 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I-E. j TOWN COMMENTS AND APPROVAL STAMP I CZ U INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, I W AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES COMPLY WITH ALL CODES OF ! OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO ALL RULES AND REGULATIONS OF THE RESPONSIBLE NEW YORK STATE & I OWN CODES -'CCUPANCY OR _ JURISDICTION. COMMENCING WITH WORK. 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS 1 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR i AS REQUIRED AND CONDITIONS OFi Q WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB 51TE DURING THE ljSF^'IS'U'NLA-WFU,L CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE SOUTHOLD?OWIv ZBA WITH �E.RTIF�CAT AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND I ,, Il.,r•J = HEALTH ADMINISTRATION.TH15 SHALL INCLUDE, BUT ARE NOT SOUTHOLD TOWN PLANN1 G BOARD CONTINUE WITH THE WORK, HE SHALL A55UME ALL i , j RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, ; OF=OCC "l l-ri 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SOU T HOLD TOWN TRUSTEES ; SHEET NAME FABRICATED AND INSTALLED AS PER LATEST A.I.5.0 SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT I SPECIFICATIONS. CONSTRUCTION. � N.Y.S.nE� p G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE COVET\ UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. 4- DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING NYS CODES*-REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING i S COh CONDITIONS PRIOR TO ORDERING MATERIALS AND I r� J n te.1- Nn u - 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN � CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS j �����RICAL. rO/�� �'�l Q/ DRAWING 5CALE 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE IT IN A LEGAL MANNER ON i fi SPECTION REQUIRED 1 CrC�- SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 1 WEEKLY BASIS LE SOONER IF CONDITIONS WARRANT. N .T.S. PROJECT FOR WHICH THEY ARE MADE I5 EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK,THE SITE TO BL CLEARED /1 Wt Ye-( 4,'[x THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LE ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE K / EXTENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASEOF (`J�, 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL ��`e.I- / FINAL PAYMENT. SNEET NUMBER EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS I RESULT OF HIS WORK. PV- I TAX MAP: 1000- 143.00-04.00-01 1 .000 LEGEN D DOSTING UTILITY METER DE51GN*DRAFTING BY: MAIN SERVICE PANEL ELEMENT ENERGY LLC • RNEW PV SUB-PANELS REVIEW BYJ.M.NA13CEPCERTIFIE A/C DISCONNECT 051112-129 COMBINER INVERTERS E) GND ELECTRODE REVISIONS RM PV MODULE DE5CRIPTION DATE REV RACFGNG RAIL OPJGINAL 09-29-2022 O ATTACHMENT POINT ---RAFTERS -4—ROOF PIT(:N ANGLE BSUNRUN METER NVENT 0PLUMBING VENT ®SKY LIGHT O rR OWNEY O CONTRACTOR ®COMPOSITE SHINGLES GOOD CONDITION �TRIYPOTENTIAL sNADINc ISSUECESSA ELEMENT ENERGY, LLC. /RE110VE AS NECESSARY 7470 SOUND AVE MATTITUCK, NY 1 195 LICENSE# 6746 I-HI LICENSE# 52689-ME PROJECT NAME N Ln I W j 00 } - LLJz ? � JU W D — i '' _ Q ACCESS ROOF t 6 33'-431 ` I s #1 5HEET NAME i N SITE PLAN 'NOTE 0° 1.)THE ROOF 5ETBACWATHWAY SHALL NOT BE 36°x 30GROUND ACCE55 TYP. / REQUIRED TO DETACHED GARAGE IN �li2jp DRAWING 5CALE ACCORDANCE WITH 8324.6 EXCEPTION Of 2020 NY5 FIRE CODE `�40° I/811 = I 1-011 -;,Jo. 4so�F CONSTRUCTION NOTE5780o 1,Sp 12p, 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 9 S 5HEET NUMBER MANUFACTURER'S INSTALLATION IN5TRUCTION5. ^�—� 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R r RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000-143-00-04.00-01 1 .000 i by _ jeftpowe,eld DUO I s r • �• �YR ca 70P BRAND PV Warranty 21 a CELLS Ra6,C 5S'mbr,:zcc �, Yield Security 7_ BREAKING THE 20%EFFICIENCY BARRIER nn/II llllnllll�IIS O_ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most ccmprehen- �Q sive quality programme in the industry_The new`Quality Controlled PV'of the independent certification institute TOV Rheinland_ INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low4ight and temperature behavior_ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID Technologyt,Hot-Spot Protect and Traceable Quality Tra_QTM. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Paj A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warrantyz_ APT test conditions according to IEC/TS 6280412015,nethod A(-1500V.96h) 2 See data sheet on rear for further information. THE:::~~IDEAL SOLUTION FOR: ^^ Rooftop arrays residential buildings Engineered in Germany OCELLS Data Sheet Enphase Microinverters Region:AMERICAS The high-powered smart grid-ready Enphase Enphase IQ 7 MicroTm and Enphase IQ 7+ MicroTM IQ 7 and IQ 7+, dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ EnvoyTM, Enphase IQ BatteryTM, and the Enphase EnlightenTMmonitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install �II Lightweight and simple IWC • Faster installation with improved,lighter two-wire cabling i Built-in rapid shutdown compliant(NEC 2014&2017) 1 Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed • Smart Grid Ready ® • Complies with advanced grid support,voltage and frequency ride-through requirements i a Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U� *The IQ 7+Micro is required to support 72-cell modules. 02h To learn more about Enphase offerings,visit enphase.com %..Of ENHAS E- Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings'_ 235W-350W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27V-45V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15_ A_ Overvoltage class DC port II II DCport backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-6-8 Hz 47-68 Hz AC shortcircuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port- III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range, -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connectortype(IQ7-60-2-US&IQ7PLUS-72-2-US) MC (or Ampheno]H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm z 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690, Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at httos://en/ phase com/en-us/support/module-com atibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com v EN PHAS E. ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 . . ►. IRONCRIDGE Flush Mount System Im �V r ,�' lwia� •ain .. zf Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating - Design Assistant Certified to maintain the fire resistance l� Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. ENPHASE. Q IQ8 and 108+ Microinverters Easy to install Our newest I08 Microinverters are the industry's first microgrid-forming,software- • Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently_The brain of the semiconductor-based microinverter - Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times • Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability • Produce power even when the :. hase grid is down' jowl } - More than one million cumulative hours of testing yea,:jrn led L --Class 11 double-insulated Part of the Enphase Energy System,I08 Series I08 Series Micminverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative • Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an Industry- and analysis software. leading limited warrarrty of up to 25 years, powered PV modules Microgrid-forming • Complies with the latest 400S Mom advanced grid support" CERTIFIED • Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily to I08 Series IQ8 Series Microinverters are UL Listed as • Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when Installed according to range of grid profiles manufacturer's instructions. • Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other •Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. ••IQ8 and I08PIus supports split phase,240V I08SP-DS-0002-01-EN-US-2022-03-17 installations only.