Loading...
HomeMy WebLinkAbout50304-Z tt . „ TOWN OF SOUTHOLD BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE jq o SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50304 Date: 2/6/2024 Permission is hereby granted to: Berringer, John 360 Clinton AveApt 5F . ...... ... ........... Brooklyn, NY _11238 To: Legalize installation of an "as built" HVAC system to an existing single-family dwelling as applied for per manufacturers specifications. At premises located at: 720 E Legion Ave, Mattituck # 473889 SCTM ........ ......... ... Sec/Block/Lot# 143.-4-13 .................... ..................... ...... pp /1 /2024 and approved by the Building Inspector Pursuant to application dated 2 1 ._ ..... To expire on 8/7/2025. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $500.00 CERTIFICATE OF OCCUPANCY $100.00 ELECTRIC $200.00 Total: $800.00 Building Inspector "a F TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 6' Telephone (631) 765-1802 Fax{631) 765-9502 htt�l /LwwE ;ac tg)E1kp �':v Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. 60�)(:)4 Building Inspector: �, V,w J A N q ,,.i. Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant Is not the owner,an Owner's Authorization form(Page 2)shall be completed. r Dater) OWNER(S)OF PROPERTY: Name: µrJ _ (�R N �-E/ SCTM#1000- 1 Lf 3 '—f — 13 Project Address: '7�.C1 E �. C ClollJ , JU A-ri/—)L)C K MY Phone#: �p Email: t. c Mailing Address: CONTACT PERSON: Name: Mailing Address: Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: 'PFC (j " Mailing Address: rg QA-ti ASE Pul o F F,/—�wbr—�-lns /i y l l 9d Phone#: OSG(�(o Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Re air ❑Demolition Estimated Cost of Project: ❑Other Tl�1�rf't Ld . .T/U/� M 1 T AGK 'NS ' --� 0 60 Will the lot be re-graded? ❑Yes)lo Will excess fill be removed from premises? ❑Yes Ao 1 PROPERTY INFORMATION Existing use of property: P FS ,DEP Tf&- Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑YesgNo IF YES, PROVIDE A COPY. —KC—heck,Box After Reading:', The ownet/co tractor/cl iSo professional is o"blp for all drainage and storm water issues 4s provided by 0apter TSo of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Suiltting Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): C36'l �. � z�/N2 ❑Authorized Agent ❑Owner Signature of Applicant: Date: C> CONNIE D.BUNCH Notary Public,State of New York STATE OF NEW YORK) No.01BU6185050 SS: ©ualifled in Suffolk County COUNTY OF ) ^ommission Expires April 14, ,0a being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this _— f ay of� r)(ALQ-r , 20 /� Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, ........ .. ....... ...residing at do hereby authorize_..... to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 I C ELECTRICAL APPROVED AS NOTED INSPECTION REQUIRED B.P # 60 3D DQ Bt NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE Berringer FOLLOWING INSPECTIONS: HVAC Load Calculations FOUNDATION-TWO REQUIRED for FOR POURED CONCRETE ROUGH-FRAMING&PLUMBING John Berringer INSULATION 720 East Legion Avenue FINAL-CONSTRUCTION MUST Mattituck, NY 11952 BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS Nowak Additional FT CertificadOn may Be Required. RHVA,CHVA,C UMql;WITH ALL CODES OF NEW YORK STATE &TOWN CODES i AS R,EQL11 'ED AND CONDITIONS OF SOMOLD TOWN ZBA SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y&DEC SOUTHOLD HPC ZSCHO Prepared By: Hamptons Air Heating And Air Conditionin 519 Montauk Highway Eastport, NY 11941 Monday, August 29, 2022 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. .,,......,..�lY V m !r gra.,.,.. .. ... .............. ., ..., r, rr rf / r rrai //// %/ ,,,, ,.✓ i//, a!/ // //` r /% ,i ,r /1lllii //.r �/,, 1 G I ". rlJm�:":" �.,,..a<ruc,,,.„tia ....urr�«N ""w Fr""",.M"C.✓ " r" .,� ". ,. / u4 ww r",",.�/..,1� ur �� 1/r /�1����ff r/r «��/ 1. "����I����,R/� �.�„���✓r��,"«/�.�., Project Title: Berringer Project Date: June 2, 2022 Client Name: John Berringer Client Address: 720 East Legion Avenue Client City: Mattituck, NY 11952 Company Name: Hamptons Air Heating And Air Conditionin Company Address: 519 Montauk Highway Company City: Eastport, NY 11941 Reference City: Suffolk County AFB, New York Building Orientation: Front door faces Northeast Daily Temperature Range: Medium Latitude: 40 Degrees Elevation: 67 ft. Altitude Factor: 0.998 Outdoor Outdoor Outdoor Indoor Indoor Grains D Bulb Y�V!t& Rel.Hum Rel.Hum Dry Bulb affprgam Winter: 10 9 n/a n/a 70 n/a Summer: 83 71 56% 50% 75 30 05 1' Total Buildin Su�� FM,ill//1/ol//?,/// /«r%2/5y✓✓///,% il � 1 ,q 1,. /., l 1 g PP y FM Per S uare ft� 0.4 Square ft. of Room Area. 625 Square ft. Per Ton: ,220 Volume (ft'): 5,000 Vol �i7 r r�z/ r/1 r,r yr /77r••:Y""'^ r Lf e Tri r ,,,,, ,,.,..,.: // .r r r p./ / //r% . /, /ri,>r � � /,.rl//r./,.. ����/�'�����/��0������ //r/%i%/i/i%/�////Oi/%1/1lr/r�i r r/ ,/////l/ �/j /w „u,., �i rr•••,.,.r....� ,.� .�.,."., �. ,,.,",". �.,:�,✓r�Gr Heating Required Including Ventilation Air: 14,963 Btuh 14.963 MBH Total Sensible Gain: 5,557 Btuh 90 % Total Latent Gain: 592 Btuh 10 % Total Cooling Required Including Ventilation Air: 6,149 Btuh 0.51 Tons (Based On Sensible+ Latent) ,%,i/, %i// f Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. _....... __... ...._._..... _.. .w.... C:\...\JBerringer Manual J.rh9 Monday,August 29, 2022, 3:07 PM r, + lfaru ar ... .. Winter: 10 9 $0% n/a 70 n/a 30.17 Main-T.Lunk Run u s Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0in 0 in v n,. ,rm „, ~h✓..�r,r „n y ,..,'� .. ,a ,., / ✓,/%/r/�/r „�„ /r,. / Winter Summer Infiltration Specified: 0.450 AC/hr 0.230 AC/hr 38 CFM 19 CFM Infiltration Actual: 0.450 AC/hr 0.230 AC/hr Above Grade Volume: _,_ 0.Q Cu.ft. X. J, Cu.ft. 2,250 Cu.ft./hr 1„150 Cu.ft./hr Total Building Infiltration: 38 CFM 19 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 8.78 = (1.10 X 0.998 X 8.00 Summer Temp„ Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.47 = (0.68 X 0.998 X 30.17 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 65.84 = (1.10 X 0.998 X 60.00 Winter Temp, Difference) Winter Infiltration Specified: 0.450 AC/hr(38 CFM), Construction:Average Summer Infiltration Specified: 0.230 AC/hr(19 CFM), Construction: Average ....\...\JBerringer Manua. ...... a...�....... ......._� .. ._._. ....,......... ......_v.... .... _. ........... _.._ _...... .I C I J.rh9 Monday, August 29, 2022, 3:07 PM .Load l�'�`er✓�� .�'� ��f ......... .. . __�... �: .��. ..........�. _..._....._.. ..� - Net ft. Sen g Sys Sys .. _ Lat' Net Sen Min Min Sys To Pion' Area Gain Gain Gain Loss H4 Clg Htg Clg Act Scope CFM CFM CFM CFM CFM 0.51 1,220 625 5,557 592 6,149 14,963 195 26..u.. _.. .w.._ . _. .. ...._.�,.,.,_......,...,,_�.., ._,.,,..,,.. 4 3 195 253 253 uilding ystem 1 0.51 1,220 625 5,557 592 6,149 14,963 195 253 195 253 253 Zone 1 625 5,557 592 6.149 14,963 195 253 195 263 253 1-Bedroom 1 And 2 625 5,557 592 6,149 14,963 195 253 t95 26,3 253 C:\...\JB. .a Manual J.rh9 Monday, August 29, 2022, 3:07 PM _M .. �' r©n���ri i;i. r �. ', t , i ,. rr�,r �c// ✓ , ��//%/ /„ ,<.�r// ,/ rr .q / /,i r/' r rid////, /f � ��`r/�i.!' r `� ' r �, ..„,.w.»�...,.,,..c�r�il..��./.�a.�✓�rw.'r!��/!f���rG�G�/,,w/,J1//µ Reg Room or Minimum Maximum' Rough DesignSP Duct Duct Htg Luc �� `e Preview _ _ _Duct Name _... .. .w_,,,,.._ Source Velocit Velocity Factor L1100 Loss VwsBccity Length W FlS?�✓ FI9V w....FIR+ .%z" ze... System 1 k Supply Runouts Zone 1 1-Bedroom 1 And 2 Built-In 0 750 0,01 0.1 429,9 195 253 3--6 Other Ducts in System 1 �, Y SuDPIV Main Trunk MMM_H MNNNwBuilt Inµmµxmm ...._0`Mµ... 900_.µM 0003 0.1 578.7 µ19S W 253 W 7x9 X rtrvµ . . . ......._. SumrnarN sy _.,. ..._ ,.. ._..... ,.... . stem 1 Heatinq Flow: 195 Coolinq Flow: 253 _.... __w ..__._ww ww......... _. ............ . ....w.. ..... C:\ .\JBerringer Manual J.rh9 Monday, August 29, 2022, 3:07 PM /1 y'�/�l�l�/��1�/%i/%ria////i/r /// p/61 /ri/',%�// p „� ,,,�//,✓rte r/!�,,,/%//,iii/i���///��/rr/>'���F�a : N r ��� r1�������jl/��1,✓�mm :, ,.�„s�l/�w�ui / rti„�,..wwuerirl® ... ...............,...._.. 1A-ry-o: Glazing-Single pane, operable window, �24 1,296 0 621 621 reflective, vinyl frame, U-value 0.9, SHGC 0.3 12B-2sw: Wall-Frame, R-11 insulation in 2 x 4 stud 776 4,004 0 967 967 cavity, R-2 board insulation, siding finish, wood studs, U-value 0.086 16C-11: Roof/Ceiling-Under Attic with Insulation on Attic 625 3,038 0 1,671 1,671 Floor(also use for Knee Walls and Partition Ceilings),Vented Attic, No Radiant Barrier, White or Light Color Shingles,Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-11 insulation, U- value 0.081 19A-Ocp: Floor-Over enclosed crawl space, No insulation 625 4,156 0 554 554 on exposed walls, sealed or vented space, passive, arelnsulationaarpp or hardwood,, U-,ya,lue5 Subtotals ,0.29 . :.. for structure: 12,494 0 3,813 3,813 People: 1 200 230 430 Equipment: 0 1,161 1,161 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 38, Summer CFM: 19 2,469 392 168 560 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: _ 0 0. 185. 185 Total Building Load Totals: 14,963 592 5,557 6,149 Total Building Supply CFM: 253 CFM Per Square ft. 0.405 Square ft. of Room Area: 625 Square ft. Per Ton: 1,220 Volume (ft3): 0 5 00 r r� G n l / ,r /, /, ,/ ,/rri / ,/ ./ / r, r /r, r// �/ <✓r rnr,,>r�,�,' llr, /. / r r / /, p 1,�///Jlil/r,/�,rj o�/%/%�,!//��,fir /,, /%%, ///�////��ir /i y., //�i. /r �ri ri„,:O...l�..�.✓� ,r...w/.wn.l,µuw l...s.,.w� Total Heating Heating Reuiredcl�ud!�Vla/tio ��/✓ �r�kBf✓,r�N✓�/r/� G,,,./1�"✓�./� Required g Btuh 14.963 MBH Total Sensible Gain: 5,557 Btuh 90 % Total Latent Gain: 592 Btuh 0 o m rr Jy lyl / ed Total Cooling Required Including Ventilation Air: 6 051 49 Btuh r r Tons Bas On Sensible+ Latent)/ s �!/ ' � � r � j��r �/����i��rriFU�rr ������r(�dro'✓��( ���/��%r/%r�f�rj;w%/%,r%nro�.%rwl(I�a��,r���1✓�I�wi������ ���21u/r �I �� /r/ Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2..50„ and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. ...._.... . .. w...... _ .. .....�. _. __... C:\...\JBerringer Manual J.rh9 Monday, August 29, 2022, 3:07 PM v r, / i/ r /�,/i�/, i i%rye✓ /,/ 1 � , /� /ri,i//�r , ✓,i //�/�ri// %r,�:a�„ / /iii//// / ,,�� � r r�� ,,,// �, Infiltration 17% Floor 28% Glass 9% Roof 20% Wall 27% Floor 9% AED Excursion 3% Infiltration 9% Roof 27% Equipment 19% i People 7% Wall 16% Glass 10% C:\ ...\JBerringer Manual J.rh9 Monday,August 29, 2022, 3:07 PM ..... ... ...u.,.... i�"` ,, r ...r yUV l 111 y"w "/ „" r .,y.,n f ' f ✓ f m ^r^ Y/'""n 7r �^^^SAY" re/'Y/ ,.Ai //��� r r �bo" 6 r W 11/rI f.g/,✓ � ,F�1/ri f /,/ //f i i. „/f /i, f /.. - Calculation Mode Htg,r & 9/�%�/lU��' '����1���, i,"�/ „�,//i����l���i����� �f,/i/1%���1�� �i�,��✓�%J�����i!��� ,e , ��� Occurrences. 1 Room Length: 25.0 ft. System Number: 1 Room Width: 25.0 ft. Zone Number: 1 Area: 625.0 sq"ft. Supply Air: 253 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.0 AC/hr Volume: 5,000 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 0 CFM Runout Air: 84 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 430 ft./min. Percent of Supply: 0 % Runout Air Velocity: 430 ft./min. Actual Winter Infil.: 38 CFM Actual Loss 0.119 in.jw�7g/100 ft. Actual Summer Infil 19 CFM 4 N -Wall-12B-2sw 25 X8 194 0.086 5.2 1,001 1.2 0 242 E-Wall-126-2sw 25 X 8 200 0.086 5.2 1,032 1.2 0 249 S-Wall-12B-2sw 25 X 8 194 0.086 5.2 1,001 1.2 0 242 W-Wall-12B-2sw 25 X 8 188 0.086 5.2 970 1.2 0 234 N-GIs-1A-ry-o shgc-0.3 100%S 6 0.900 54.0 324 13.0 0 78 S-GIs-1A-rv-o shgc-0.3 0%S 6 0.900 54.0 324 19.5 0 117 W-GIs-1A-rv-o shgc-0.3 O%S(2) 12 0.900 54.0 648 35.5 0 426 UP-Ceil-16C-11 25 X 25 625 0.081 4.9 3,038 2.7 0 1,671 Floor-19A-Ocp,25 X 25 625 0.295 _ 6.6,_ 4,156 0,9 _ 0 _ 554 Subtotals for Structure: 12,494 0 3,813 Infil.: Win.: 37.5, Sum.: 19.2 800 3.086 2,469 0.210 392 168 AED Excursion: 185 People:200 lat/per, 230 sen/per: 1 200 230 Equipment: _ _ 0 1,161 Room Totals: 14,963 592 5,557 l / I/ � � r%% , //,"�� .�/ / J/ ;,✓ mf,,, p, /„il /j///�i//.��„ ,,. // �,i//!f%o�//%l it/��/////�l��r�.�, �� 1 Y i lr; s i J � 1707'r � 50 .50 ” 427 Vented clothes dryer- 10 percent to space 0 Clothes washing machine- 10 percent to space 205 0 50 50 51 0 Color television _ 683 0 100 100 683 01 Total _ 1161 0 ernnger..... .... ... .. .. _ _.... C:\...\JB Manual J.rh9y Monda August 29, 2022, 3:07 PM .M.,._._ .......... M ---Zone 1--- I !Bedroom I And 2� a.....m. .5.._. ..14„963 195_ 3- . _430 5,557 592 .. 2513-11---- I `3.. ...... , System-! total 625 14„963 195 5 55 5 253, 253 System 1 Main Trunk Size: 7x9 in. Velocity: 579 ft./min Loss per 100 ft.: 0.104 in.wg ��� ��' / n' l I r i Net Required: 0.51 90/a/10 /0 5,557 592 6,149 0 0 ��1�, ��ir1��✓(Cr��'�u�� ����� ��"%,:'� �I/��� i:/l/�/��%///�� �/�����✓/%�/�//�/��ll��d����a✓r�:��!' �' Rri����Y/lv.IJ” Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh CA...WBerringer Manual J.rh9 Monday, August 29, 2022, 3:07 PM . • Job Name: System Reference: .......... ........... .............. .. ............ .......... Date A, FEATURES • Variable speed INVERTER-driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 56 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: MXZ-3C30NA2 (For data on specific indoor units,see the MXZ.c Technical and Service Manual.) Rated Capacity Btu/h 28,400 27,400 i Cooling* Capacity Range Bo/h 9,500-28,400 %500-27,400 (Non-ducted I Ducted) .......... ........... .. ............... Rated-total Input W 2,680 2,860 ........... ....... w. ............. Btut.... ...... ,7,g '�V 64' "..... 771 eating 1 Rated Capacity Blu/h 16,000 15,100 ........... (No cted/Ducted) Rated Total Input W 2,120 2,140 ........... ........ V aa zz' U­1 Power SupplyVoltage,Phase,Hertz 208 230V,1-Phase,_.6.0..Hz Electrical Requirements Recommended Fuse/Breaker Size A 2 5 . ..... -.......... MCA A 22 1 Electrical a ........ ........... V /7, N,a INVERTER-driven Scroll Hermetic C res .......... x Cooling dB(A) 52 Sound Pressure Level Heating dB(A) 56 ii i A", In .. ..... f,795,X 95Q,X PPTT .......... �Xmlxm Net Weight Lbs kg 13/(62) ............. ....... ............... No,3'y"7,9)1I Liquid(High Pressure) In I min 1/4(127) Refrigerant Pipe Size 0 D .......... Gas(Low Pressure) In/mm A1/2(6,35),B 318(9 52) ...................... Ft(in 230(�O) Max Piping Length for Each Indoor Unit Ft in 62(25} M 777//7777 7' FtIm 15 a 5 g 1 /mo N I 0, Flared/Flared Connection Method ........... ...........jf84 i0A % 7 54 Rating Conditions perAHRI Standard: 17°F I Indoor 70°F(21°C)08 Cooling I Indoor:B01 F(27°C)DB/67°F(19'C)WEI Heating at 47°F I Indcmr,70°F(21°C)DB I ietating at I Cooling I Outdoor 95°F(35°C)DO 175'F(24°C)WB Heating at 47°F I Outdbor:47°F(8°C)DB 43°F(6°C)WB Heating at 17°F I Outdoor:17°F(-6°q 08 1151 F(-9°C)WB OPERATING RANGE. ENERGY EFFICIENCIES. Outdoor Indoor Unit Type SEER EER HSPF COP @ 47-F COP @ 17°F ��colin.......... 14 to 115"F(-10 to 46'C)DB Non-ducted 19,0 116 10,6 390 2,77 C ........ (09,09,12) H.eating 5 to 65'F 1-1 5 1 o 18"..C)W B Ducted and 176 1CL1 101 377 2,78 Non-ducted Ducted16,2 96 96 3,64 2,76 .......... (09+09+12) ... ...... ­­ . .._„a..,,,,,,,..,,...... ........... .. ............ NO-FES For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to i Operacnai Performance. Although the maximum connectable capacity can exceed rated,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same firne Specifications are subject to change without notice GO 2021 Mitsubishi Electric Trane HVAC US LLC All rights reserved, 777 OUTDOOR UNIT ACCESSORIES: ,A11 ir Outlet G11 uide Air Outlet Guide(1 Piece) ❑ PAC SH965G-E .. 6S dRefrigeration Ball Valve-1/2" n BVI2FFSI2 1 Refrigeration Ball Valve-1/4 ....... ....... _.. .._.. _. .... Lf OV14FFS12,._ .... Ball Valve - I ,...,, ..... _.... �RefngeraYion Ball Valve-3!6" .._.. . ... _. F; BV3Ef 1512.... ,....... Refrigeration Ball Valve-5/8" _ OV58F FS12, Distribution pipe for Branch Box -.... M-NET Converter.... ,,.,.. ........, ,_.. ,3 &'xAR'3"d6"dJ3MNT-E, -- Drain Socket Drain Socket PAC SG60DS-E 1 Hail Guards.... ..... ,..... Hail Guard Condensing Unit Mounting Pad. 16"x 36"x 3" ❑ ULTRILII'F1 .....Mounting Pad ,, , .. ,h Mountin, ... ..... _. .� _ _ Outdoor Unit 3-1/4 incg Base(Pair)-Plastic ,.. r1 GSD400P Optional Defrost Heater Base.Heater n PAC-645BH-E .. ,.... ._. -- Adaptor.1/2"x 3/8" .,... ...... ❑ MAC-A455JP-E _.. Adaplot:112'x 518" .. ._. ....... ._ ..... ❑ MAC-A456JP-E IPort Adapter -' ""' - " -' ❑ MAC-A454JP-E Adaptor,3/£ x 112" Adaptor 3/8'x 5/0" .. ._. ....... ..... O PAC SG76RJ-E ...._.,„ Power Supplies and Auxiliary Components M Not Control Wire,1,000'Roll(16 AWG Standard,Twisted Pair Shielded Jacketed-Plenum rated). ❑ CW162S-1000 i Power Supplies And Auxiliary Components M-Net 11 Control Wre 250 Roll(16 AWG Standard Twisted Pair Shielded Jacketed-Plenum rated) t„Wt62S-250 ..,,...,, ...�..,, ...... .,. -.. 16 Single_. ..,.--•" FanStond ... n ,OSMS1601M ._ 24"Single r] OSMS2401M Fan Stand .,_.. ... .... -- ...... _... .. Stand Condenser Wall Bracket .. _ ._.... `F) GSWB200OM-1 .. Condenser Wall Bracket-Stainless Steel Finish n OSWBSS _ Outdoor Unit Stand--12"High O'tSMS1201 M Specifications are subject to change without notice. Cc7 2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT DIMENSIONS: Unit: inch ty R—Am ,mue (F—dol­Boll M10) .41 �A .. �r Y� A a name .... ...,,w_ kM^r:Abo°aJ�ful',w+'x Boll M161 1 107"' 2-$719'knockoul hole ti RR? v11 ° -- .1,08[2;^CN1111 hole 4C FI.VY91#pCkM!R"� FIYOIeW w'W"7.kA y.www ., .,,..•...,. ....................... .w.........-...... .,.....9 ..�.........., C'" M.y iQ}U s LIO 1/4 Im635 FLARE u�..�.. ....,.,.,.,. N.1 4@I tt �^^ rypp��r d l i D pF GAS 3l9'Im,5,FLARE L10 114 1 5)FL ARE A— GAS ill'1m2371FLARE :. ..�. .... .... ...... ...........w ........ .......n i r ...... .......� *Mm , .��,..µ�... .... w r+x 1.FREE SPACE p ,nrnm r� ^a�+s^ r�'k«'w/� .ncrvu�^�rw Conduit plates "f Conduit connector 2.SERVICE SPACE , / � - Lock m�bp ^^A' SER4ILE SP CE 14 i fi ;�a'va �1-U�as 9C d ,x5xa 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com -0111 FORM#M_SUBMITTAL_MXZ-3C30NA2_en-202108 Intertek Specifications are subject to change without notice. C 2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. � ffl BUILDING DEPARTMENT- Electrical Inspector Ee TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 r Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 amesh southoldtownn ov — seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Peconic Bay Electric Corp Electrician's Name: Jose Umana License No.: ME-46360 Elec. email:pecbayelec@gmail.com Elec. Phone No: 631-987-4406 ❑1 request an email copy of Certificate of Compliance Elec. Address.: 218 Oak Avenue, Flanders NY 11901 JOB SITE INFORMATION (All Information Required) Name: John Berringer Address: 720 E Legion Avenue, Mattituck NY 11952 Cross Street: North Riley Avenue Phone No.: (646) 284-4507 BIdg.Permit#: 503D± email:jberringer@reedsmith.com Tax Map District: 1000 Section: Block: 4 Lot: I BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of Mitsubishi Condenser Square Footage: Circle All That Apply: Is job ready for inspection?: YES[] NO DRoughln b/I Final Do you need a Temp Certificate?: YES 0 NO Issued On Temp Information: (All information required) Service Size 01 Ph[]3 Ph Size: A # Meters Old Meter# F1 New Service❑Fire Reconnect[—]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 LJ H Frame Pole Work done on Service? DY MN Additional Information: PAYMENT DUE WITH APPLICATION ic" y I f I I f 1 CA �f 00 bo 00 O o Ca z z I •N0 0' @ .0 ` , r lir Ww O O � l a z .04 44 r W o , if Acnd t } G r u ' >z r w NYSE New York State Insurance Fund PO Box 66699,Albany,NY 12206 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE no . '� . ^"A^^A 474882046 LOVELL SAFETY MGMT CO., LLC 110 WILLIAM STREET 12TH FLR ... w. NEW YORK NY 10038 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER HAMPTON'S AIR HEATING AND JOHN BERRINGER AIR CONDITIONING INC. 720 EAST LEGION AVENUE P.O. BOX 121 MATTITUCK NY 11952 EAST QUOGUE NY 11942 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z2552 064-4 103163 04/01/2023 TO 04/01/2024 1/04/2024 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2552 064-4, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/MIWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT JUNIOR MARTE VICE PRESIDENT LUIS DEL CARPIO TWO OF TWO OFFICERS HAMPTON'S AIR HEATING AND AIR CONDITIONING INC THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND 4 DIREc,rOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 878391849 U-26.3 / CERTIFICATE OF LIABILITY INSURANCE DATE 104/2024Y) 01/04/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT N"K; Farm Family Casualty Insurance Company PHONE , .631-727-7767 � 631-727-7941 18 First Street MAIL enf kirk t 4pp� � ,..... mr ... arm tarnll)P com Riverhead, NY 11901 INSURER(S)AFFORDINGCOVERAGE ..... NAIC# INSURERA: Farm Family Casualty Insurance Company 13803 _..,..,...ry..w.._......... .._..w.. INSURED INSURERB: United Farm Family Insurance Company 29963 Hamptons Air Heating and Air Conditioning Inc INsuRERa, POBOX 121 . .___.__ ..... .... ..... .....,�..,._.....�....... .._...._.._......_...w.w_... ........._.... INSURER D INSURER E East Quogue NY 11942 INSURER F COVERAGES CERTIFICATE NUMBER; REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OFSUCH POLICIES,LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. iil 'if° __ ..._ CitStTC'titilt ................. _" IScillerEF .. oucv'EZP . ...... ....w... T TYPE OF INSURANCE TNSD1WVD POLICY NUMBER MWDD/YYYY MM/DD/YY LIMITS A X COMMERCIAL GENERAL LIABILITY X 31021_7031 07/28/202307/28/2024 EACH OCCURRENCE $ 2,000,000 O4Af; W rLli ri iJ ---,,........, CLAIMS-MADE IX.. OCCUR 50 000 ABILITY MED EX (Any one person $ X CONTRACTUAL LI _ ...P.. 5,000... ....... .... _ PERSONAL&ADV INJURY $ 1,000,000 GFWLAGGREGATE LIMIT APPLIES P A RE A _... ......................._.........,00 ...., PER: GENERAL AGGREGATE $ 4,000,000 X..' ❑ PRO. ❑ __ .P/O JECT POLICY LOC PRODUCTS COMP/OP AGG $ 1,000,000 OTHER $ B AUTOMOBILE LIABILITYC, WED tN LELIMi $ 1000000 X 3101C2522 07/28/2023071 8j b24 ppc�rtl ANY AUTO BODILY INJURY(Per person) $ X OWNED L SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS hRTY HIRED NON-OWNED µPROPDAMAGE AUTOS ONLY AUTOS ONLY RC*1r. 4,Cca(frr8l $ $ I B X UMBRELLA LIAB OCCUR X 3101E2359 07/28/2023 07/28/2024 EACH OCCURRENCE $ 1,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED 'RETENTION$ $ WORKERS COMPENSATIONPER OTH- ANDEMPLOYERS'LIABILITY YIN STATUTE. ANYPROPRIETOR/PARTNER/EXECUTIVE ❑ E1.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A . _ ........ (Mandatory in NH) E L DISEASE EA EMPLOYEES$ If yes,describe under ........ . -.,,,,___ _..,..._, _.,..w, DESCRIPTION OF OPERATIONS below E L DISEASE POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE MOLDER CANCELLATION .John Berringer SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 720 East Legion Avenue THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Mattituck, NY 11952 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Kirk Associates LTD O 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD I l�P 503o - ,:�-e oR5 Berringer HVAC Load Calculations for John Berringer 720 East Legion Avenue Mattituck, NY 11952 RHVA, CHVAC LOAD$ Prepared By: Hamptons Air Heating And Air Conditionin 519 Montauk Highway Eastport, NY 11941 Monday,August 29, 2022 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. ley ki am onsair Meaty 8� C r ^ Mt f" Vw rY V L. Project Report Project Title: Berringer Project Date: June 2, 2022 Client Name: John Berringer Client Address: 720 East Legion Avenue Client City: Mattituck, NY 11952 Company Name: Hamptons Air Heating And Air Conditionin Company Address: 519 Montauk Highway Company City: Eastport, NY 11941 - Reference City: Suffolk County AFB, New York Building Orientation: Front door faces Northeast Daily Temperature Range: Medium Latitude: 40 Degrees Elevation: 67 ft. Altitude Factor: 0.998 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel um Rel.Hum Dry Bulb Difference Winter: 10 9 n/a n/a 70 n/a Summer: 83 71 56% 50% 75 30 heck Fi'uses° 1b. 0%� y .. ::.. Total Building Supply CFM:, 253 CFM Per Square ft.: 0.405 Square ft. of Room Area: 625 Square ft. Per Ton: 1,220 Volume(ft3): 5,000 Total Heating Required Including Ventilation Air: 14,963 Btuh 14.963 MBH Total Sensible Gain: 5,557 Btuh 90 % Total Latent Gain: 592 Btuh 10 % Total Cooling Required Including Ventilation Air: 6,149 Btuh 0.51 Tons (Based On Sensible+, Latent) y Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\JBerringer Manual J.rh9 Monday, August 29, 2022, 3:07 PM 'Rtivac=:FEesiderlal&Light,Cornmercisl HVAC Loads:::,•r:, :,:,::.: `.7 Elife SofLvuare l}evelopmerrt,:iric::. ,:Hamotonsaip dating&'aC, ~` Barringer � a l' Miscellaneous Report ;Outdoor :Outdoor.; ;;Outdoor,:, :: indoor `•'-:; lndoar,�`a Grains a5o «mi� �'� F ;.! � w. ..,. u{tz. ...Wet ulb R' I Hum': "R I:f�ium...,..p .Bul ifference� Winter: 10 9 80% n/a 70 n/a Summer: 83 71 56% 50% 75 30.17 Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. SOuts'itle�'Air!Data'r: - - 'f Winter Summer Infiltration Specified: 0.450 AC/hr 0.230 AC/hr ................................._....... . .................. ............... ...... ....._ ..38...._CFM._......... ......... 1.9___CFM...... ............ ..... ........ . ...................................... Infiltration Actual: 0.450 AC/hr 0.230 AC/hr Above Grade Volume: X 5.000 Cu-ft. X 5,000 Cu.ft. 2,250 Cu.ft./hr 1,150 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 38 CFM 19 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 8.78 = (1.10 X 0.998 X 8.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.47 = (0.68 X 0.998 X 30.17 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 65.84 = (1.10 X 0.998 X 60.00 Winter Temp. Difference) Winter Infiltration Specified: 0.450 AC/hr(38 CFM), Construction:Average Summer Infiltration Specified: 0.230 AC/hr(19 CFM), Construction: Average C:\...\JBerringer Manual J.rh9 Monday,August 29, 2022, 3:07 PM t MAE-Residentia#. ` s `„ 3 '%` " Elite�Softwa"rs Develo ent�inc. 8�fLight Gormneii FIifAC- Coads fte Hamptotlsair Heating&A/C :. �•'"" . a7� ,,,,; n9 Y x. . Load Preview Report Net ft.zSen Lat Net Sen Min Min Sys Sys Sys Scope Ton /Ton Area 1 Gain Gain Gain Loss F Clg Htg Clg Act CFM CFM CFM CFM CFM Building 0.51 1,220 625 5,557 592 6,149 14,963 195 253 195 253 253 System 1 0.51 1,220 625 5,557 592 6,149 14,963 195 253 195 ..253>• 253 . . . . Zone 1 625 5,557 592 6.149 14,963 195 253 195 7.253' 253 1-Bedroom 1 And 2 625 5,557 592 6,149 14,963 195 253 195 253! 253 C:\...U13erringer Manual J.rh9 Monday,August 29, 2022, 3:07 PM �EthYac-i2eside tial�IL�ightGomEneccialHVACLoac y� ";K:' Mite}SoflwareDelo�epmetrt,Ince Wamptonsair y _ Barringer age D -E Al"N'TIMMU1,94 Duct Size Preview Room or Minimum Maximum Rough. Design SP Duct Duct Htg Clg Act. Duct Reg Duct Name Source Velocity Velocity Factor U100 Loss Velocity Length Flow I w Flow Size Svstem 1 Supply Runouts Zone 1 1-Bedroom 1 And 2 Built-in 0 750 0.01 0.1 429.9 195 253 253 3--6 Other Ducts in System 1 Supplv Main Trunk Built-In 0 900 0.003 0.1 578.7 195 253 253 7x9 Summary _ System 1 Heatinq Flow: 195 Coolinq Flow: 253 r 1 C:\...\JBerringer Manual J.rh9 Monday, August 29, 2022, 3:07 PM 1 Rb;vacReliclenfiaitllghtsCoiiimer #ai HVAC loads'. _ Elite Software_Developmerit;inc Ha tormair Heati r&,A/G,NY T1 . r ,Be (,► : w•f. %4 1 . i l, Total Building Summajy Loads Component �,-; Area T` Laf Sen Total Des ri t'on n. , ;7-.,.Z, .<Quawe :',. ALas Gain:• Mw,Gain. _ Gain. 1A-ry-o: Glazing-Single pane, operable window, 24 1,296 0 621 621 reflective, vinyl frame, U-value 0.9, SHGC 0.3 12B-2sw: Wall-Frame, R-11 insulation in 2 x 4 stud 776 4,004 0 967 967 cavity, R-2 board insulation, siding finish, wood studs, U-value 0.086 16C-11: Roof/Ceiling-Under Attic with Insulation on Attic 625 3,038 0 1,671 1,671 Floor(also use for Knee Walls and Partition Ceilings),Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-11 insulation, U- value 0.081 19A-Ocp: Floor-Over enclosed crawl space, No insulation 625 4,156 0 554 554 on exposed walls, sealed or vented space, passive, no floor insulation carpet or hardwood U-value 0.295 Subtotals for structure: 12,494 0 3,813 3,813 People: 1 200 230 430 Equipment: 0 1,161 1,161 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 38, Summer CFM: 19 2,469 392 168 560 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: Q.._..__............__._...._-_. 0_._........ 185 1.85 _.........._.............---...._.....................-...._.......__...._....................•..._.._...._..__._.........._.................................._.._..........._..............._..........................__.._.........................._....._...........--- Total Building Load Totals: . 14,963 592 5,557 6,149 Che k`�a `` Total Building Supply CFM: 253 CFM Per Square ft.: 0.405 Square ft. of Room Area: 625 Square ft. Per Ton: 1,220 Volume(ft'): 5,000 OBuilding La di, T... Total Heating Required Including Ventilation Air: 14,963 Btuh 14.963 MBH Total Sensible Gain: 5,557 Btuh 90 % Total Latent Gain: 592 Btuh 10 % Total Cooling Required Including Ventilation Air: 6,149 Btuh 0.51 Tons (Based On Sensible+ Latent) 41Votes � ,,: :.i�r'�iiy'..L'#,;}`J�.�,y.`..:5 :.r:,sx*�w$» •.ib'1 - ;i'E. i3 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\JBerringer Manual J.rh9 Monday,August 29, 2022, 3:07 PM Rhvac=Resider�ti�!`&,Light GommerciaYHVAC I:oaiis- _ EliteSo_ftware.Deveioprrier�t,lnc:. 'Hamptbh&iir Heat!nd&AICBercing®i io '1. FB-uildin.q Pie Chart Infiltration 17% Floor 28% Glass 9% 1 , Roof 20% Wall 27% Floor 9% AED Excursion 3% Infiltration 9% a.; �9 Roof 27% Equipment 19% People 7% Wall 16% Glass 10% C:\...\JBerringer Manual J.rh9 Monday, August 29, 2022, 3:07 PM °Rhvaa Resideritial:.&LIght:Commorciat'HVAC Loads, opm rrt;lrtc '� �} Elite�.oftvirare Devei r-nma,s`rs<2.K—efa"4van:zto,�-w.; `.'..s" Be* 1. P Y' 9- 42 Detailed Room Loads - Room 9 - Bedroom 9 And 2 Average Load Procedure Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 25.0 ft. System Number: 1 Room Width: 25.0 ft. Zone Number: 1 Area: 625.0 sq.ft. Supply Air: 253 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.0 AC/hr Volume: 5,000 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 0 CFM Runout Air: 84 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 430 ft./min. Percent of Supply: 0 % Runout Air Velocity: .430 ft./min. Actual Winter Infil.: 38 CFM Actual Loss: 0.119 in.wg./100 ft. Actual Summer Infil.: 19 CFM h...moo {, ..��,. p., i." ..li. Oft� - '. i,,..' '..„}� , .;s,ry :r a' 4:'a' ,.; gym,:: °',:::; .: 9 ,aLaf ,'S'en'.. emi 'Are''a ' ., ::,m{ U ;t. ;>� ar::Ht9 ; Senn Cl :,r'tron r mki?ri«k+i kiss : .x,.ti!^' `... rvj ,gv.r ..b.: ..Quanti :Value:;. ,. Garro. HTM°” .y. Los's" HTM . Gare N-Wall-126-2sw 25 X 8 194 L 0.086 5.2 1,001 1.2 0 242 E-Wall-126-2sw 25 X 8 200 0.086 5.2 1,032 1.2 0 249 S-Wall-12B-2sw 25 X 8 194 0.086 5.2 1,001 1.2 0 242 W-Wall-1213-2sw 25 X 8 188 0.086 5.2 970 1.2 0 234 N -GIs-1A-ry-o shgc-0.3 100%S 6 0.900 54.0 324 13.0 0 78 S-GIs-1A-ry-o shgc-0.3 0%S 6 0.900 54.0 324 19.5 0 117 W-GIs-1A-ry-o shgc-0.3 0%S(2) 12 0.900 54.0 648 35.5 0 426 UP-Ceil-1 6C-1 1 25 X 25 625 0.081 4.9 3,038 2.7 0 1,671 Floor-19A-0cp..28_X 25.....__.._..............._..._.__......................_.............._.._625---............._......_...295._...__......................._..-6.:_6......-- ......4..,_x._56................_._...._. 0...9................------.............0-.--......_._...__._._......554_. Subtotals for Structure: 12,494 0 3,813 Infil.: Win.: 37.5, Sum.: 19.2 800 3.086 2,469 0.210 392 168 AED Excursion: 185 People: 200 lat/per, 230 sen/per:' 1 200 230 Equi.pment ._....--..__........... — --.............._.._..................................---................._...................._...... ._....--.......................................-....--.................._....._..__ ...__.... ......_._....................--- .._0....-........_1.,_16.1_. I. Room Totals: 14,963 592 5,557 f.�€`�F:.^`.,v'L,.f`.: "`^'.v='et,�6 •.t„- _ ,-. .r .+�. .�z��,.-,�-.n�,:��,�,i;i,``(,":;�,;3�� "�� ,� ." ., ��`°:_,�,�.t� '•�� Sens.',.;.. Lat:���fin.Use, 'Used` � •Load Load' Item Marne £: Btuh" ' BtuFi. Out at 4'/Houc r: .Btuh-- Btu Vented clothes dryer- 10 percent to space 1707 0 50 50 427 0, Clothes washing machine- 10 percent to space 205 0 50 50 51 0 C . .......... .......... ............. ................._.._..............._....................._._......_.........._...... ................ Total 1161 0 C:\...\JBerringer Manual J.rh9 Monday,August 29, 2022, 3:07 PM [FREA iivac.=Resldentiat&,Ud tt�Corhineicial,HVAC,.1:oads:.__ _ :-. __ _ . - - Elite 5oftvira velapmerrt,,inc. Hampfbnsaif;:Heabng&A/C .a' ,_,~ Barringer S stem 9 Room Load Summajy Gi Run. Run, :C ;r`y°Min; Acts , 9, Roam � . Asea , tg ,Dunt', Diic#= Sens 4Lat, `;s ,Clg Sys; fi. `CFM ize Vel. Btuh i3tuh. ---Zone 1--- 1 Bedroom 1 And 2 625 14,963 195 3-6 430_ 5.557 ----- 592 _ 253 253 -----5ystem_..1-total ----- ..-625.-- 14,963.._.._... ---195 .....__.._.._._.._._.._............__....._.._..---- ...._.. -- 5,557.--..—_......._59.. ..._-...- —253—.._....._..?53_ System 1 Main Trunk Size: 7x9 in. Velocity: 579 ft./min Loss per 100 ft.: 0.104 in.wg C wlin''S m6 Sur A _ Latent-j Total Cooling� '` '�SerisibleLL"a_fent Sensib)eE =,;; .,. ' ,,� 5\,'1M-,'W-x-4"' t .$t�" ;�?'�e.� °s[7^tt,.:.r.,.",�.' .,'Y'Yi'y�v',',...., ..,,4;.., �, �,', ;,..y� ,:,b ,,t Tons Slit` i3tut :Btuh:. :•.: {.sBtuh. Net Required: .. 0.51 '90%..i q 10% 5,557 592 6,149 ui bment�Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\...\JBerringer Manual J.rh9 Monday,August 29, 2022, 3:07 PM 1 MULTI-ZONE INVERTER HEAT-PUMP SYSTEM Wlk Fd Job Name: System Reference: Date: � III�11 IIIB IIIII� .� . FEATURES • Variable speed INVERTER-driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 56 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection Specifications are subject to change without notice. 0 2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: ' + (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Rated Capacity Btu/h 28,400/27,400 Cooling' Capacity Range Btulh 9,500-28,400/9,500-27,400 (Non-ducted/Ducted) Rated Total Input W 2,680/2,860 •,RatedCapacity g Capaaly Range Bluth 15,600-36,000/,1 5,60D-35,000 Ratad Total Input- 2,220 Heating at 17'F' Rated Capacity Bluth 16,000/15,100 (Non-ducted/Ducted) Rated Total Input W 2,120/2,140 Connectab�eCapaelry'' Btulh 12,000=36,000 Power Supply Voltage,Phase,Hertz 208/230V,1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Indoor-OutdoorSlS2' V AC 2087230 'V Its a go?twos•✓' 'r Indoor-Outdoor S2-S3 - V DCf24 - Compressor INVERTER-driven Scroll Hermetic FanrMotw(ECM). Cooling dB(A) 52 Sound Pressure Level Heating dB(A) 56 'Eit"terijel Dlmensions,(H-X W x-D) ` 37-13132 z13' 13 mm (796 X 950 x 330}- Net Weight Lbs I kg 137(62) Exlemal Fin,ish " .,,' Munsell No.3Y x.8/11 Liquid(High Pressure) In/mm 1/4(12.7) Refrigerant Pipe Size O.D. Gas(Low Pressure) In/mm A:1/2(6.35);B,C:3l8(9.52) Max Refrigerant Line Length_ Ft I m 230(70) Max.Piping Length for Each Indoor Unit Ft/m 82(25) Max Refrlgyeranf Pipe Hei If IDU Is Above ODU Ft!m 49(i5) 9M Dllierence' - Ft!in - 49(15) - - HIDU;isBelow ODU�- - _ - Connection Method Flared/Flared 1, Refrigfllartt. Rating Conditions perAHRI Standard: Cooling)Indoor.80°F(27°C)DB 1670 F(19°C)WB Healing at 47°F I Indoor.70°F(21°C)08 Heating at 17'F Indoor.70°F(21°C)DB Cooling)Outdoor 95°F(35°C)DB/75°F(24°C)WB Heating at 47°F Outdoor.47°F(8°C)DB 143°F(6°C)WB Heating at 17'F Outdoor.17°F(-6°C)OB 115'F(-9°C)WB OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ 47-F COP @ 17-F Cooling 14 to 115'F(-10 to 46'C)DB Non-ducted 19.0 10.6 10.6 3.90 2.77 (09+09+12) Heating 5 to 65'F(-15 to 18'C)WB Ducted and 17.6 10.1 10.1 3.77 2.78 Non-ducted Ducted 16.2 9.6 9.6 3.64 2.78 (09+09+12) NOTES: For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. Although the maximum connectable capacity can exceed rated,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. @ 2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT ACCESSORIES: MXZ-3C30NA2 Air Outlet Guide Air Outlet Guide(I Piece) 0 PAC-SH96SG-E Refrigeration Ball Valve-112" 0 BV12FFS12 ..............I........................................................ ....................... ...................... ................................. ...................................................................... ........... .......... ................ .............. Refrigeration Ball Valve-114" ' BV14FFS12 BallValve ................................................... ........................ .................. ................................................. ............................................... ........................ Refrigeration Ball Valve-3/8" 10 BV38FFS12 ................................................................... ....I.................. .......... ................................................... ............... ................................................................................................................................................ ............... Refrigeration Ball Valve-5/8" 0 BV58FFS12 "Distribution' p'ipe for­i3_*r;'n*'ch* B"cx ............ Converter ;0 PAC T* Drain Socket Drain Socket ............................LoP.AC-SG60.D.S.-.E................. ... ......... ............ ............ ................... ............................................................................................ Hail Guards Hail Guard El HG-A9 Condensing Unit Mounting Pad:16"x 36"x 3" 0 ULTRILITE1 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic 0 DSD400P ......................._.-h............. ...... . ......... ........................................................................................................................... ...........................................---------------------- .................. Optional Defrost Heater Base Heater o PAC-645BH-E ................... -............................... .............. ..................................................................... .............. -.................. ...................... Adaptor.112"x 3/8" o MAC-A465JP- E .............. ....................... ........................ ....................­_.................................... ..................... ..­............................. Adaptor:1/2"x 5/8" 0 MAC_A456JP-E PortAdapter .................................................................... ............................. ............I.................... ............................................................. Adaptor'.3/8"x 1/2" 0 MAC-A4WP-E ................. ........... ............................................................... .....-.............I.......................... ............................_... Adaptor:318"x 5/8" 1 Cl PAC-SG76RJ.E 1 ................. .................................. Power Supplies and Auxiliary Components M-Net Control Wire,1,000'Rall(16-AWG.Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) D CW162S-1000 —---------- Power Supplies And Auxiliary Components M-Net Control Wire,250'Roll(16-AWG,Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) 10 CW162S-250 18"Single Fan Stand ic] QSMS1801M i ........................................................ .. .....................-.....................I..................................... ........... .................-....................................................... ................ . .......... .................................. i 24"Single Fan Stand ❑ ........................Q.SM§2401M Stand Condenser Wall Bracket D QSVVB2000M-1 ....................................-----------....................... ....... .............. Condenser Wall Bracket-Stainless Steel Finish i 0 QSWBSS .. ...... ... ........................................................ ............._ Outdoor Unit Stand—12"High 10 QSMS1201M Specifications are subject to change without notice. (9)2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT DIMENSIONS: 1 + Unit:inch 6-7/8' OR—Am Inlmke 2-13/16' 9-1/16' 2-1/32' [1-11116'13/32' 3/32 ` S Sime All mimke Q 6-01-5/16'Drain HoleArt n 13/32' acl,mram 13/32- 2-715/32'x1-13/32'1 Oval Hole 1-1/32' 2-0/8'knockoul hole (Faundollon Ball 14701 (Conneclin wire hole) 1-5/8' 37-13/32' 31/32' 13' 19/32' 3-m7/8'punchetl hole (Connecting wre hale) Mare nRmnNe O� Rmnme wore E 2-3/4' Au Intake O® GAS Ur,l C 1 LIa I1<'(m6.35 I.— La l 1 GAS 3r81m9521FLARE GAS A l Urn/A_Ll. IIC'W2.711FLARE GAS f GAS 1/2'Im12.11FLARE 1-11/32' 14-7/32' ).FREE SPACE E E w E 3-15/16'or more p B 4 7?TJ 3-15/16' or more 13-25/32'or more Conduit plates 2.SERVICE SPACE o m z t Conduit connector E ` 1• - �V O E Lock nut 3-15/16'ar mare SERviCE SPACE 13-25/32' .1 more 13-25/32'or J I 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ' cO�I us FORM#M_SUBMITTAL_MXZ-3C30NA2_en-202108 Intertek Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.