Loading...
HomeMy WebLinkAbout49811-Z p' Town of Southold 10/27/2023 a P.O.Box 1179 0 C* ; 53095 Main Rd 11y�,01 �ao� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44691 Date: 10/27/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 7175 Route 25,East Marion SCTM#: 473889 See/Block/Lot: 31.4-4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/14/2023 pursuant to which Building Permit No. 49811 dated 10/2/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Chamale,Juan of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49811 10/19/2023 PLUMBERS CERTIFICATION DATED t 0r' Signature .."zMItrTOWN OF SOUTHOLD o�SUFFat,��oG BUILDING DEPARTMENT M z ' TOWN CLERK'S OFFICE ` SOUTHOLD, NY W _ BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49811 Date: 10/2/2023 Permission is hereby granted to: Chamale, Juan 7175 Main Rd East Marion, NY 11939 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. At premises located at: 7175 Route 25, East Marion SCTM #473889 Sec/Block/Lot# 31.-1-4 Pursuant to application dated 9/14/2023 and approved by the Building Inspector. To expire on 4/2/2025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector pG SO(/jyol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1]79 G Q t' Southold,NY 11971-0959 Oly� N �� sean.devlin �town.southold.ny.us �Uffm BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Juan Chamale Address: 7175 Route 25 city:East Marion st: NY zip: 11939 Building Permit* 49811 section: 31 Block: 1 Lot: 4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 8.1 kW Roof Mounted PV Solar Energy System w/ (20) qpeak gcell G10 405W- Modules, IQ4 Combiner, 40A Fused AC Disconnect Notes: Solar Inspector Signature: Date: October 19, 2023 S.Devlin-Cert Electrical Compliance Form qo$ �opF SOUl`` * # TOWN OF SOUTHOLD BUILDING DEPT. couto N 631-765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL�ol piv-' [ ] FIREPLACE & CHIMNEY ( ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ✓cG U� DATE l0 l INSPECTOR �o��pF SOUTyOIo � l V � � �, � NG DEPT. * # B ,LDI TOWN OF SOUTHOLD U 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /-STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ PRE C/O [ ] RENTAL REMARKS: DATE G INSPECTOR LELD INSPECTION REPORT DATE COMMENTS rr 4"b FOUNDATION (IST) OQ 3 C FOUNDATION (2ND) m z 0 a� v H ROUGH FRAMING& a PLUMBING (N N INSULATION PER N.Y. *3 STATE ENERGY CODE FINAL r Az ADDITIONAL COMMENTS Up c in io 373 0 z m � k Nb o z x y x d b H �oo-%af vlj*r- o TOWN OF SOUTHOLD —BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny_ oovv Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only a PERMIT N0. Od Building Inspector: SEP 14 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owns'i,an Building Depafinent Owner's Authorization form(Page 2)shall be completed. Town of Southold Date: e) OWNER(S)OF PROPERTY: 11 Name-1k".. . Ch_G�►�ne�-1 .. S-- - # 1000-..�_..�..,..... . . L.. ..r.._.. Project Address: '7, rj .0 .. .1.V1=7 vlj 11 —1 Phone#: ..1- _[. 7.��3 Email:. Mailing Address: CONTACT PERSON: Name: Mailing Address:`3_,4 '1 0.. sSv�n Phone#: to3 l-`7.�. _ ..� a. 3..:__..._ . W. Email: +✓ l'Yl7TS._..��.._. o� . .�_ .Gc�m DESIGN PROFESSIONAL INFORMATION:' Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION:I— Name:...E �.�YYiQ,O'}.._ _t°i.Y�.�✓� __._ . Mailing Address: `') L4 Phone#: Email•{/�/� DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition [:]Alteration ❑Repair ❑Demolition Estimated Cost of Project: Other-CIULS h (06f 1'YMgiu*A . sptov-- f1)/s\4s-krn $ c>�Will the lot be re-graded? ❑YesNo Will excess fill be removed from premises? ❑Yes Flo $L �w - .;)0 )nV" r: En C—PKA-' r C 0 $ 1Pbl46 `-2-�--a — C;-%D t-i o d.-Lt-les J t� Ct) - !Q Pea--K. "Duo g I I"� . -C�1 r? q oS, W cru r, ►2,`rt�, aha a modem )(Q 10-0 1 PROPERTY INFORMATION Existing use of property: _ Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? [!�l(es ONO IF YES, PROVIDE A COPY. -ECheck Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): I Qr P Authorized Agent El Owner Signature of Applicant: Date: C90 149, Q6 STATE OF NEW YORK) r SS: COUNTY OF &44:b 1 � ) LO Yr a I a_�_ -b VIef-,kms being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the CjL)cIi4ya (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this �U trhis n day of .1• )JV , 200 ,5 k) lJl. -rt_� Notary Public DEBRA A SEPULVEDA X0rMY PWU4 SPATE OF NEW Y0R>r. PROPERTY OWNER AUTH RIZATI A16tionNooismi2697 (Where the applicant is not the owner)QuOifi�m My Commission Expires o�a i � 1l,, I, D 5WCA 1 <4O LhQ r-)0 6 residing at �� H CAI C\ �0a do hereby authorize_cIt✓Y1 ejnt&,XQ� )—LC to apply on my behalf to the Town of Southold Building Department for approval as described herein. e Owner's Signature Date .f-\5&0bq dV C ka nt" Print Owner's Name 2 ,1; st,��oGy BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD 0 2 Town Hall Annex - 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrasoutholdtownny.gov - seand(a)_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: q, Company Name: k � t hcrLL-C- Electrician's Name:-J-o- ,1"c-..., M L"n 6 L lL License No.: j -2_(,o 2 c l- �-te Elec. email: J ,c r rrt P+S S ' S .cvro Elec. Phone No: (,? -7-2 --?cjc�3 ®I request an email copy of Certificate of Compliance Elec. Address.: () S oLAjIA GC V�,, I`-Lcc+H"uc, N _ l 1 5 JOB SITE INFORMATION (All Information Required) Name: J Ch & rnkio Address: -71 -1 5 MGLI I�� e Gk-S+ "(l>rl"O r-) I C1 3(u Cross Street: Phone No.: tz3 (.--T-2q--7-993 Bldg.Permit #: q7Wemail: Pe—rry)i S Q,-e a S 6. CQ h-) Tax Map District: 10 0 Section: 31 . Block: I Lot: 9 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly �ns-1 o�-1 Leh��--1 c� -F -� 1 v�S ►�'m o h'1 l�L�rl, .a�� ran ce- Pc- )e-. 1.}C�Ib Square Footage: Circle All That Apply:D-o-Envef Is job ready for inspection?: ❑ YES 0 NO ❑ Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (Ali information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# [--]New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 D H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION g�FFflt, BUILDING DEPARTMENT- Electrical Inspector ���✓y ' TOWN OF SOUTHOLD o - Town Hall Annex - 54375 Main Road - PO Box 1179 - ` F , Southold, New York 11971-0959 4,, 0 Telephone (631) 765-1802 - FAX (631) 765-9502 �L rogerr(cD-southoldtownny.gov -- seand[D_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: q, Company Name: E e � t hcl' L.,L-C- Electrician's Name:uo-m ) IkA c-o 11 .d lC License No.: j �Q Or- KIF Elec. email: re-,r to+S �S S ,CvaYl Elec. Phone No: -7-29 I request an email copy of Certificate of Compliance Elec. Address.: t) �S oUjA ., 0,V%(,, I—tcL- +),,c )( N y JOB SITE INFORMATION (All Information Required) Name: J 1 v 0) 6, rnkiO Address: .7I -7 :5 rna I�4, ee s+ No-dor- ! 1 3(p Cross Street: Phone No.: Bldg.Permit#: email: Pe-rry-)i S (o,-e a s S. CQhl Tax Map District: tion: l , Block: I Lot: Ll BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearlly�: ,Ll O -F ► -� 1 v�5 c9 0 ►'�l U'V a� rc�s1 eL 5o 1 e,--r P\/, �S-err► ��o�U� � ) t Loo r9c rio�(-� Q 9/k �-L t�+G t� r Square Footage: Circle All That Apply:a0-rnv0 Cnpn"-C� )QZ8 u.s---7)-X-% Is job ready for inspection?: ❑ YES D NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES [—/] NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 0 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION A`C?R CERTIFICATE OF LIABILITY INSURANCE DATE(M 7/"'°/2o THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endomement(s). PRODUCER NTACT ROBERT S.FEDE INSURANCE AGENCY NAME. PHONE - FAX _ _ E-MA 23 GREEN STREET,SUITE 102 N.°Eft AIC D: HUNTINGTON,NY 11743 ADDRESS: W ROBERTS.FEDE INSURANCE BNsu AFFORDING COVERAGE NAIC a INSURER A:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURER B*STATE INSURANCE FUND 523930 . Element Energy LLC INSURER C- DBA ELEMENT ENERGY SYSTEMS INSURER D: GENERAL STAR MANAGEMENT Co. -373ST- 7470 SOUND AVENUE INSURER E: MATTITUCK, NY 11952 INSURER F: COVERAGES - COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. (LTR TYPE OF INSURANCE POLICY NUMBERPO(MMLICY EFF POLICY EXP LIMITS COMMERCIAL GENERAl.LIABILrrY L1480036873 EACH OCCURRENCE S 3,000,000 AX X 711412(123 7/14/2024 CLAIMS-MADE IX-1OCCUR PREMISES Ea occurrence S 100.000 MED one pemn) $ 5000 X Contractual Lia ED EXP( A3as2o38 7/19/2022 7/19/2024 PERSONAL a AoV IMA1Y s 3000000 GERL AGGREGATE UMITAPPLIES PER: GENERAL AGGREGATE 3 3.000,000 PRO- POLICY K JECT LOC PRODUCTS-COMPIOPAGG t 0000 O7HER: 3 AUTOMOBILE LIABILITY COMBI SWGLE LIMIT s ANY AUTO BODILY INJURY(Per person) f OWNED SCHEDULED BODILY INJURY Per accident AUTOS ONLY AUTOS ( ) f HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY iper accident3 s UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED RETENnCNS Ig WORKERS COMPENSATWN AND PMPLOY£RT LIABILITY Y f N 12449444$ SAT ER ANY PROPRIETORMARTNERiEXECUTNVE 7/1312023 7/1312024 S B OFFICENMEMMR EXCLUDED? ED N N A EL EACH ACCIDENT 1,0D0.000 (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE S describe yes,desoe under 1 ZOO= DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LINIT f NY State DBL DBL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS 1 LOCATIONS I VEHICLES(AC;;D 7D1,Additional Remarks Schedule,maybe attaeRe4lf more apace is regldred) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including cornpleteted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,IVY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHCROW REPRESENTATNE R&IY r S- Fede ©1988-2015 ACORD CORPORATION. All rights reserved. -.bn-4 Amor, /Ok\ NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) � Q A"AAAA 823336604 ROBERT S FERE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07113/2023 TO 07/13/20247/11!2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/IWWW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED ASA MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU CE FUND DIRECTOR,INSURANCE FUND UNDERWRITING Yfl workers'STATE Compensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carne 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1 c.Federal Employer Identification Number of Insured Work Location of InsuredOn/ or Social Security Number { yrtrqufrsd ifcaverage is spBcrRcailylimited to certain locations in New York State,ie.,wrap-up PoNcy) 823336604 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Shelterpoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"1a" SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/0112023 to 12/31/2024 4. Policy provides the following benefits: ® A-Both disability and paid family leave benefits. HB.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. C) B.Only the foilowing class or classes of employers employees: Under penalty of perjury,1 certify tttat I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By �&f (signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent ofthat insurance carrier) Telephone Number 516-829-8100 Name and Too Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carer,this certificate is COMPLETE.Mail it directly to the certificate holler. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. it must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box 48,41C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form OB-120.1.Insurance brokers are NOT authorized to issue this form. DB-126.1 (12-21) 111111lll1111111111111111111111111 f ED AS NOTED OCCUPANCY OR APPROVED USE IS UNLAWFUL DATE: o- 3 e.P ��� WITHOUT CERTIFICATE FEE NOTIFY BUILDING EPARTMENTAT OF OCCUPANCY 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION ti 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. COtvIPL`T WITRALL; ODES;;OF ALL CONSTRUCTION SHALL MEET THE h EW YORK STATE &TOWN- ; REQUIREMENTS OF THE CODES OF NEWA$REQUIRED AND`.CONDITIONS QE YORK STATE. NOT RESPONSIBLE FOR ' DESIGN OR CONSTRUCTON ERRORS ,St,UTHOIDTOWN Z$A. SpUil{�LQTOWN Pt VN'Nt�`8w, SOUWTOYYN 7"TEES. :N:Y.S�.DEC• 01 Now oiiiogow(dogv m i RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. Zoho Sin Document ID:2A768FFA-MIQJXDP38KUWCDBMAE5MDVS78_LLUFCGZBZSMIXIIEG DESIGN 2 DRAFTING BY: 50LAP ARRAY ON MAIN HOUSE 8.1 kW ELEMENT (20)QCELL Q.PEAK DUO BILK ML-G 10+ 405 WATT PV MODULES ENERGY LLC (1)STRING OF(1 1) MICRO-INVERTERS*(I)STRING OF(9)MICRO-INVERTERS REVIEW BY J.M.NABCEP CERTIFIED '(2)STRINGS TOTAL TO UTILITY GRID 051 1 12-120 PEV1510N5 STKI NG #I DESCRIPTION DATE REV L1 L2 N ORIGINAL 08-18-2023 ----------------------- - ---------------- -- G -�G G'- G'- -�G�- -�G�- G-- G -�G�- �_ _�G BI-DIRECTIONAL _ I O UTILITY METER I I-PHASE, 4 ---�� MICRO-INVERTER L1 L2 N I ENPHASE 108PLU5-72-2-U5 I I . I.2 I A PEP,NEC O ) 4(A) POINT OF INTERCONNECTION 240 VAC 97%CEC-WEIGHTED EFF. LENGTH OF TAP CONDUCTOR5 STKI NG #2 NEMA G.UL LISTED SHALL NOT EXCEED 10 FT I TYPICAL - -- - -- G G G G G G G G G I CONTRACTOR MAIN SERVIC_DISCONNE`..'T I _ ----� �----� �----� �----� �----� �_--_� �---�� �_---� 240 V.150A I ELEMENT ENERGY, LLC. ENPHASE BRANCH 7470 SOUND AVE CIRCUIT CABLE TYPICAL MATTITUCK, NY 1 1952 Ll L1 LICENSE# G74G I All ENPHA5E AC COMBINFza AC D15CONNECT L2 Lz LICENSE # 52689-ME I 240 VAC.80 A \� I GA 7_W Im Y JENIA K.UL U5TED 50 D D223NP5 _ (2)20 A DOUBLE POLE 5P.FAKEP5 240 VAC.60 A (I)1 5 A DOUBLE POLE BREAKER NEMA 3P,11-'11T1' L1 CLI GATEWAY/GOMMVIJIG4T10N DEVICE Q ` - (2)40A USS OF NCiV 1 20A I ,20 A 1 15 A L2 L2 4N GPLV .4 y'. 40 A 1 I 1 Ll 3L2 :� L2 MAIN SERVICE PANEL 0 I W ru n 1-PH.3-W •_.- g�z,i- 1 240 VACr"- r' ----- G -----------------------------� 150A 1 ! a r- -- --------------------- Q <7J�+ Ali _ I EXISTING GROUNDING j II ELECTRODE SYSTEM PROJECT NAME ILL- m : z 0 LU LLJ L------------------------------------ -------------J - 1 - I WIRE CONDUIT SCHEDULE � z z CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% DZ LL_I _ I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION S17_E QUANTITY INSULATION (CU/AL) TYPE 51ZE TEMP DEBATE DISTANCE QJ 0-7 Q z 310.15(5)(3) 310.)5(5)(2a)/(3c) 00 I INVERTERS COMBINER PANEL AWG#12 1 4 0.8 USE-2/PV Wire AWG#8 1 BARE CU FREE AIR 111 559C 0.84 90 FT 2.84% (n J CLI - OR EMT LU Q 2 COMBINER PANEL MAIN PANEL AWG#8 1 3 I THWN-2 AWG#8 I THWN-2 CU PVC I" 459-C 0.95 50 FT 1.26% (s) 3 COMBINER PANEL MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#8 I THWN-2 CU PVC I" 45QC 0.95 10 FT O.I G% U l W SHEET NAME ELECTRICAL NOTES CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 3-LINE DIA. 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. (NEC 690.8(5)(1)]: (Isc)'(#of strin '(I.5G) = I G.G4 A 3.)WIRING. CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY gs) Modules per String I MAX. TO, AND LOCATED AS CL05E AS POSSIBLE TO THE NEAREST RIDGE. HIP, OR VALLEY. AWG#12. a y'Temp Derate= 20.I G A G.G4 > I .G4 therefore C were size 15 valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 20.I G COMPLY WITH NEC 1 10.26. #2 Inverter Output W Wire Ampacity Calculation Number of Inverters 20 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 30.25 A Record low temp -109C FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE550PJE5 TO FULFILL AWG#8,> 30.25 A. t p Deor eA(Cwire 5i FIII Derate) = 52.25 A Voc Temp Coefficient 0.24%/QC DRAn�NG SCALE APPLICABLE CODES AND 5TANDARD5. 52.25 A> 30.25 A. therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS Calculation acit Output Wire Am t O Inverter uppy G.)WHERE SIZES OF JUNCTION BOXES. RACEWAYS. AND CONDUITS ARE NOT SPECIFIED, #3 InverO eratin Current 10.8 A I n I�J . . THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Amperage output'(1.25) = 30.25 A 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G, ampaclty'(Temp Derate)'(Conduit FIII Derate) = 71.25 A Operatinq Voltacle 37.4 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A> 30.25 A, therefore AC wire size is valid. Max.System Voltage 49.6 V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14 0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR IL5CO GBL-4D5T LAY-IN LUG. Max AC Output Current 30.25 A �\ /_ 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5itive/negative) �/O eratin AC Volta e 240 V OR 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000-031 .00-01 .00-004.000 Zoho Sign Document ID:2A768FFA-MIUJXDP38KUWUDBMAE5MDV878_LLUF(;(3ZBZSMIXIIEU . a Town of Southold August 25th, 2023 Building Department Town Hall Annex j 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Chamale Residence, 7175 Main Rd, Ridge, NY 11961 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.9 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, OF NEW Gennaro Anthony Giustra. P.E. Great Eastern Services, Inc. _ , PO Box 240 24 Harvey Rd '`"4 ' w Riverhead, NY 11901 Mobile: 631.235.0189 Email: jerrygiustra@gmail.com 'Zoho Siah Document ID:2A768FFA-MIQJXDP38KUWCDBMAE5MDVS78 LLUFCGZBZSMIXIIEG SCOPE OF WORK DESIGN t DRAFTING BY: ELEMENT ENERGY LLC TO INSTALL A 8.1 KW SOLAR PHOTOVOLTAIC(PV)5Y5TEM AT CHAMALE RESIDENCE, REVIEW BY J.M.NABCEP CERTIFIE LOCATED AT 7 175 MAIN RD, EAST MARION, NY 1 1939. 75 n p-'�)' THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS DESCKIPTION DATE SYSTEM RATING �CCI ORIGINAL 08-15-2023 East. ' 8.1 kW DC 5TC 25 P.P^nd l EQUIPMENT SUMMARY 20 QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES 20 ENPHA5E I08PLU5-72-2-U5 MICRO INVERTERS Greenport I IRONRIDGE XRI 00 MOUNTING 5Y5TEM CONTRACTOR tewGreenport(� ELEMENT ENERGY, LLC. SHEET INDEX 7470 SOUND AVE PV-I COVER Dering Harbor � MATTITUCK, NY 1195 PV-2 51TE PLAN PROJ ECT LOCATION LICENSE # G74G I-HI PV-3 ROOF PV LAYOUT LICENSE# 52089-ME PV-4 STRUCTURAL/DETAILS 4 SECTIONS PV-5 3-LINE ELECTRICAL DIAGRAM PV-G LABELS GOVERNING CODES �V," oo � r 2017 NATIONAL ELECTRICAL CODE. 2020 RESIDENTIAL CODE OF NEW YORK STATE. 2020 FIRE CODE OF NEW YORK 5TATE. ASCE 7-1 G AND NFPA-70. � UNDERWRITER5 LABORATORIES(UL)5TANDARD5 303„►S 05HA 29 CFR 1910.269 � yW GENERAL NOTES z PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT 11J QTHE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE u- U Q HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK wZ O AGREE THE SAME. AERIAL VIEW LLJ 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED E APPROVALS, PERMITS, CERTIFICATES O OCCUPANCY, I0. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP w _z INSPECTION APPROVALS, ETCICTI FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, - - g � }- AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. Q COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES O z 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND N t1J ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO o J JURISDICTION. COMMENCING WITH WORK. N Q LL._I I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS O UL WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE 0 THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS U ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND R/HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SHEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SCAFFOLDING, STAIRS, ETC.. A5 WELL AS PERMANENT COVER FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 CONSTRUCTION. SPECIFICATIONS. 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE E5TABL15HED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. 4 CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES 4 REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S DRAWING SCALE CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS 8. THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE IT IN A LEGAL MANNER ON ^I .T.5. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 1 WEEKLY BASIS LE SOONER IF CONDITIONS WARRANT. I V I PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. 14. AT THE RIS AND EXCIONESS OF WORK, THE SITE FA IL CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE EXTENSIONS TO THIB PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF SHEET NUMBER EXISTING WORK ADJACENT TO H15 WORK, OR DAMAGED AS FINAL PAYMENT. PV- I RESULT OF HIS WORK. TAX MAP: 1000-031 .00-01 .00-004.000 _Zoho Sign Document ID:2A768FFA-MIQJXDP38KUWCDBMAE5MDVS78 LLUFCGZBZSMIXI IEG LEGEND TAX MAP: 1000-031 .00-01 .00-004.000 De51GN s DRAFTING BY: EXISTING UTILITY METER4/ - MAIN SERVICE PANEL ,V ELEMENT ENERGY LL.. REVIEW 8YJ.M.N NEW PV SUB-PANELS /n_ Qo 051 112-120 2-1 2CERTIFIE 0 CA/CO DISCONNECT , COMBINER 2�Qo INVERTERS D GND ELECTRODE 2g� REVISIONS DESCRIPTION DATE REV PV MODULE C RACKING RAIL -P' ^\1 0 o9�°F ORIGINAL 08-18-2023 O ATTACHMENT POINT 78Oo 7S`O o,�Oo ---RAFTERS S F�DOF PITCH ANGLE ❑'�JNRUN METER ®I2NT O°._UMBING VENT ®SKY LIGHT ®CHIMNEY COPfiRP.CTOR CMPOSITE SHINGLES ELEMENT ENERGY, LLC. TODD CONDITION 7470 SOUND AVE 'OTENTIAL SHADING ISSUES G"X 3G"GROUND ACCE55 TYP. V/REMOVE AS NECESSARY MATTITUCK, NY 1 195 O LICENSE # G74G 1-111 LICENSE # 52G89-ME pF NEiy Y r t Access Roof PROJECT NAME 0 w � m 18'FIRE SETBACK @RIDGE U- U Q co w z O W 401-8411— z z 0 O 15'-G2" LD LD J o oz w Q < o Q �- ® (T) U [� , EW PV AC D15CONNECf l u I 11 15TING UTILITY METER SHEET NAME I rJ-82 —� rJ-4 (STING MAIN ELECTRICAL SERVICE PANEL SITE PLAN `NOTE I .)THE ROOF 5ETBACK/PATHWAY SHALL NOT BE REQUIRED ON ROOF-5LOPE5 WHERE THE DRAWING 5CALE OPP05ING OR ADJACENT ROOF SLOPE 15 AN ACCE55 ROOF IN ACCORDANCE WITH R324.G.I I 1-011 EXCEPTION OF 2020 NY5 RESIDENTIAL CODE. V CONSTRUCTION NOTE5 1 .)ALL EQUIPMENT 5HALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NUMBER MANUFACTURER'S INSTALLATION IN5TRUCTION5. P\ /_ 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. I �/ 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. _lZoho Sin Document ID:2A768FFA-MIQJXDP38KUWCDBMAE5MDVS78_LLUFCGZBZSMIXIIEG CONSTRUCTION SUMMARY DESIGN i DRAFTING BY: (20)QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULE5 ELEMENT ENERGY LLC (DIMEN51ON5: 74"X 41 .1"X 1 .3") REVIEW BY J.M.NABCEP CERTIFIE (20) ENPHA5E IQSPLU5-72-2-U5 MICRO INVERTER5 'V Os 1 1 12-129 (GO)ATTACHMENT POINTS @ 72"O.C. MAX. Oo (248.3) LF IRONRIDGE XKI 00 MOUNTING 5Y5TEM. "!�� REVISIONS ROOF TYPE: ASPHALT 5HINGLE (SINGLE LAYER) �0� , F_ _ ION DATE REV CONSTRUCTION NOTE5 2QOo Ds-Ib-2023 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 2 Q WITH THE MANUF ACTURER'S INSTALLATION INSTRUCTIONS. 70° O 90a c� _ 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 7800 7SOa7-.) MINIMUM NEMA 3R RATING. cs 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. CONTRACTOR ELEMENT ENERGY, LLC. 6"x 36"GROUND ACCESS TYP. 7470 SOUND AVE MATTITUCK, NY 1 1952 O LICENSE# 6746 I-HI LICENSE # 52689-ME ��OF N EIy y A � 1 PCCE55 ROOF X03;A3 {(i PROJECT NAME W C) 18"FIRE SETBACK QRIDGEu_ U co w z O------------- ELI w z � z q V PANEL TIP. g cz z I-VII 0 J ICRC-INVERTERTYP. Q Q ® LEGEND Q EXISTING UTILITY METER D_ u W MAIN SERVICE PANEL EW PV AC DI5CCNNECT NEW PV SUB-PANELS A/C DISCONNECT 15TING UTILITY METER COMBINER S EE NAME INVERTERS ARRAY#I I5TING MAIN ELECTRICAL SERVICE PANEL (B GND ELECTRODE 20 MODULES TR1NG/CONNECTION TYP. P,MODULE FV LAYO U T 370 PITCH —RACKING RAIL 1440 AZIMUTH o ATTACHMENT POINT W ---RAFTERS -*—ROOF PITCH ANGLE �SUNRUN METER I/Q11 I 1_011 ®VENT CCJI 'NOTE 0PLUMBING VENT 1 .)THE ROOF 5ET13ACK/PATHWAY SHALL NOT BE ®SKY LIGHT REQUIRED ON ROOF-SLOPES WHERE THE ®CHIMNEY SHEET NUe MB` OPPOSING OR ADJACENT ROOF SLOPE 15 AN ACCE55 ROOF IN ACCORDANCE WITH 8324.6.1 PV-3 ®COMPOSITE SHINGLES GOOD CONDITION EXCEPTION OF 2020 NY5 RESIDENTIAL CODE. TENTIAL SHADING ISSUES TAX MAP: 1000-031 .00-01 .00-004.000 ❑TRIM REMOVE AS NECESSARY 'Zoho Si "n Document ID:2A768FFA-MIQJXDP38KUWCDBMAE5MDVS78 LLUFCGZBZSMIXI IEG LOAD CALCULATION ARRAY#I ITEM DESCRIPTION ARRAY#I D�_51GN s DRAFTING BY: 'RB Ride 5earll/15oard 2"X 10" D. FIR ELEMENT ENERGY LLC MODULE WEIGHT(Lb5) 48.4 R Rafter 2"X 8" D. FIR P 24" O C REVIEW BY J.M.NABCEP CERTIFIE (D) Decking 5/8" PLYWOOD 051 1 12-129 #OF MODULES 20 C Collar Ties 2" X 4" D. FIR 24" O.C. (J Cellrn Joist 2" X 6" D. FIR 24" O.C. REV151ON5 TOTAL MODULE WEIGHT(Lbs) 968.0 (P) Pitch 37DE5CRIPTION DATE REV ° TOTAL LENGTH OF RAIL(Ft) 248.3 11 1-iorizontal Span Of R 123" MAX. ORIGINAL 05-25-2023 RAIL WEIGHT PER FOOT(Lbs) O.G8 TOTAL RAIL WEIGHT(Lbs) I G8.8 (RB) #OF STRANDOFFS GO (R) WEIGHT PER 5TRANDOFF(Lbs) 2 (D) TOTAL STANDOFF WEIGHT(Lbs) 120 TOTAL ARRAY WEIGHT(Lbs) 125G,8 POINTLOAD(Lbs) 20.9 CONTRACTOR TOTAL ARRAY AREA(Sq ELEMENT ENERGY, LLC.Ft) 428.2 7470 SOUND AVE ARRAY DEAD LOAD(Lbs/Sq Ft) 2.9 MATTITUCK, NY 1 1952 GROUND S IRM wI/IETat ICE YAIlilmI ALL rrrw (P) LICENSE # 52G(59-ME SNOW Spead Teoor"apt c Spwal WbUUbOret pgIM from DES" IMVIFR;Ar►UEN* FLOOD FREDNG AIIIIIIIIIIIIIIIIIIIAL LOAD° Unph) effecto CATV.09 E MOMAwW 8- r4low rcW, of NEIV 20 140 No NO No B S 3 FT t5 F YES 599 51'F Q 0 A Q MANUAL J DeSIGN CtlTBIAP J) � � i t Etevatoor Latitude Winer SurwUrbumv th heandiallfAWh factor teww—aly!0-9" Us�R� anse�ba mr W tompelatme 108 FT 41'N 115'F 88'F 100 77 F 75`F 56`F (H) I �Q 10,A3 Y Coding Wbof � ColnddryK I `^ESS10 wellockv Daft u-Milt SurUwtt cmperacure 11 omenvrre C-111111111111; ret bulb raUr�e hUUwUl�l� 15 MPH 7S MPH 72'F MED4)M(Urn 40% 32 GR @W%RH PRO C' 'AM For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 rr✓s. ROOF FRAMING DETAIL n OW C) 67 U U Q m a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth w W O strength required for weathering shall govem.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. t j b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction >_ shall fill in the frost line depth column with the minimum depth of footing below finish grade. W z Z C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R3D1.2(5)A].Wind exposure category shall be determined O Q Z on a site-specific basis in accordance with Section R301.2.1.4. O e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York MODULE MOUNTING CLAMP W State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[AlsoQ see Figure R301.2(1).] 50LAP MODULE I� f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. 5TAINLE55 5TE`L 3/A O 0l g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New BOLT AND NUT O Q _ York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the OC Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: � U ` ` W I.The accompanying Flood Insurance Rate Map(FIRM), NRIDGE ALUMINUM RAIL ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. ALUMINUM^r'SPACKeT SHEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905A.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ALUMINUM FLASHING effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." STRUCTURAL L The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method ASPHALT 5HINGLE ROOF (Base 32°F)." 5/1 G"x G"5TAINLE55 5TEEL LAG BOLT WITH k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 2 1/2"MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION SEALED DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements. OR BETTER) requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. mAS NOTED . In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table la or lb from ACCA Manual J or established criteria determined by the jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. SHEET NUMBER (') See Figure R301.2(4)B. � PV-4 TAX MAP: 1000-031 ,00-01 .00-004.000 MOUNTING DETAIL Zoho S"n Document ID:2A768FFA-MIQJXDP38KUWCDBMAE5MDVS78 LLUFCGZBZSMIXI IEG 50LAK ARRAY ON MAIN HOUSE 8.1 kW D--51SN a DRAFTING BY: (20)QCELL Q.PEAK DUO BILK ML-G 10+405 WATT PV MODULES ELEMENT ENERGY LL-- (1) LC(1)STRING OF(1 1)MICRO-INVERTERS d(1)STRING OF(9)MICRO-INVERTERS REVIEW BY J.M.NA6CEP CERTIFIE '(2)STRINGS TOTAL 051 1 12-1 29 TO UTILITY GRID REVISIONS 5TKI NG # I DE5CRIPTION DATE REV ---------- G L1 L2 N ORIGINAL 08-16-2023 - - - - - - - - - BI-DIRECTIONAL I UTILITY METER t ------------------ G G G G G G G G G G- - _- �- '- �- �- -- �- �----' �----' �----' I-PHASE.240 V MICRO-INVERTER L1 L2 N I I ENPHASE IQ8PLU5-72-2-US 240 VAC. 1.2 1 A POINT OF INTERCONNECTION I 97%CEC-WEIGHTED EFF. PER NEC 240.2 I(B)(I)t G90.G4(A) STRING #2 NEMA G.UL LISTED SIEN'TlMALL NOf TAP CONDUCTOR5 OT EXCEED 0 Ff TYPICAL 1 iII G G G G G G G G zoo CDNTRAC?JR :7.1"rIA5E MAIN 5ERVICE DSCONNECT V.150A ELEMENT ENERGY, LLC. BRANCH I CIRCUIT CABLE TYPICAL 7470 SOUND AVE MATTITUCK, NY 1 195 u u I ENPASE AC COMBINER 4 AC DISCONNECT LICENSE # G74G I -HI VAC* I 240 AC.80A L2 z LICENSE # 52689-ME I Jj NEMA 3R.UL u-. 50 D D223NRB (2)20 A DOUBLE POLE BREAFER5 240 VAC.60 A (I)15 A DOUBLE POLE BREAKER NEMA 3R.UL USTED � OF NEwFOR DOUBL POLE5UN104TION DEVICE (2)40 A FUSESL2 L2n. ZOASA 40AA ' O--- r r L1 L1 I 1 I L2 L2 MAIN SERVICE PANEL 1 M M 1 I-PM.3-W 240 VAC r- __ S ----- 5 --------------------------------------------------� 150A G +v I I N _ 1� I I I I I G _-j I I I I I I I I I I I EXISTING GROUNDING I I 1 ------------U i ELECTRODE SYSTEM OC PROJECT NAME I i O W Q 6� Q co O I I U W - L------------------------------------- -------------J WIRE CONDUIT SCHEDULE C)C) CZ - LU z z CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop LU _ I.D. # ORIGIN DESTINATION 51ZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CLYAL) TYPE 51ZE TEMP DEBATE DISTANCE g a/ Q Z 310.15(B)(3) 310.15(5)(2aU(3c) O INVERTERS COMBINER PANEL AWG#1 2 1 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I" 55QC 0.84 90 FT 2.84% O� J OR EMT p Uj Q 2 COMBINER PANEL MAIN PANEL AWG#8 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 45QC 0.95 50 FT 1.2G% 3 COMBINER PANEL MAIN PANEL AWG#6 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 45QC 0.95 10 FT 0.IG (L Q F 0- U W ELECTRICAL NOTES 5HEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS I.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 909C WET ENVIRONMENT. [NEC G90.8(B)(1)]:(Isc)'(#ofstnn s)'(I.5G) = I G.G4 A 3-LINE DIA. 3.)WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY g Modules per String I I MAX. TO, AND LOCATED AS CL05E AS POSSIBLE TO THE NEAREST RIDGE,HIP,OR VALLEY. AWG#12,a G.G4y'Temp Derate=re I G A 20.I G A> 16.64 A,therefore DC wire size Is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 20 COMPLY WITH NEC 110.26. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output'(1.25) = 30.25 A Record low tem -I OQC FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE550RIE5 TO FULFILL AWG#8,ampacity'(Temp Derate)"(Conduit FIII Derate)= 52.25 A Voc Temp,Coefficient -0.249c/QC DRAWING 5CALE APPLICABLE CODES AND STANDARDS. 52.25 A> 30.25 A,therefore AC wire size Is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation THE CONTRACTOR SHALL 512E THEM ACCORDINGLY. Inverter Max Amperage output'(1.25) = 30.25 A Operatinq Current 10.8 A N .T.S . 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G,ampaclty'(femp Derate)'(Conduit FIII Derate)= 7 1.25 A Operatinq Voltacle 37.4 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A> 30.25 A,therefore AC wire size Is valid. Max.System Voltacje 49.9 V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEER LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR IL5CO GBL-4DBT LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(positivelnegatwMax AC Output Current 30.25 A OR e) 10peratinci AC Voltage 1 240 V PV-5 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000-031 .00-01 .00-004.000 Zoho Si n Document ID:2A768FFA-MIQJXDP38KUWCDBMAE5MDVS78 LLUFCGZBZSMIXIIEG SERVICE METEROI O INSTALLATION NOTE DESIGNBDRAFT6Y ELEMENT ENERGY LLC REVIEW BY J.M.NABCEP CER— SOLAR PV SYSTEM ! PHOTOVOLTAICPHOTOVOLTAIC. . ( 1 ) ALL LABEL 5HALL DE INSTALLED IN 051112-129 EQUIPPED WITH ? SOLAR BREAKER ° • ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® OPERATING • •OPERATING REQUIREMENTS. REVISIONS DESCRIPTION DATE RFV (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 08-15-2023 MAX SYSTEM VOLTAGE VDC SOLAR AC LOAD CENTER - OUTSIDE DO NOT RELOCATE THIS ,. REQUIRE FIELD VERIFICATION. �OVEWLSWIINMIN ` (3) LADEL5, WARNING(5) AND MARKING O3 TUR14 PAM 9trD0VMSM04TO O I� SHALL BE IN ACCORDANCE WITH NEC TME•ate•POMM M SHUT DONN I 1 0.2 1 (B). I PV S MW AW RMUCE W=WZRDNTWAWAY AC DISCONNECT PM"TO ��$L@".M (4) THE MATERIAL USED FOR MARKING MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - INSIDE 2� 4 '""°�"� COMPLIANCE WITH NEC 1 10.2 1 (B)(3). CONTRACTOR (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLQ. ® O ® 1 1 O �NIN '- 7470 SOUND AVETIIIIS SHALL BE LABELED I N5TALLED I N IMATTITUCK, NY 1 1 95 S TOM PJJ I�OFALL WATPLE DIAL SUPPLY +� COMPLIANCE WITH NEC 690.3 1 . LICENSE # G74G 1-HI OVERCi RIM DEVICES-�� SOURCES:UTLITY GRD LICENSE # 52G(59-ME Ww91PrlYD IR++err AND PV SOLAR DEVICE.9141 Nor EXCEEDELECTRSYSTEM I CONDUIT - INSIDE BUILDING YOFeusW IC ��pF NEIy Y 0 ARNING yP� ° A a�f ILWARNING II THIS SERVICE METER �+ Is ALSO SERVED 6Y A ELECTRIC SHOCK K42ARI) TETtIH1•ALSONTHEL•ENO I PHOTOYOTAIC NERPA EL 1 µµ COMBlER PANEL =I PHOTOVOLTAIC SYSTEM – 2 --- — — 1.� LOAD SAES MW BE E)BMM I, DO NOT ADO LOADS 1 10340 07KOFEMPOSMON CONDUIT - OUTSIDE BUILDING — PROJECT va':� 0 W "MALOWER SUPPLY O Q m � z SOURCES:UTLITY GRID AND LLI W -- I PV SOLAR ELECTMC SYSTEM i• N LY — MAIN SERVICE PANEL - OUTSIDE O A CAUTION SOLAR CIRCUIT Q W Z z ACAUTION _ souR ELECTWC SrsrE►+CONECTED Q 1 • • • • O u^1 © ' • O l cj Z MAIN SERVICE PANEL - INSIDE U w POWER SOURCE I OUTPUT CONNECTION ® O DO NOT RELOCATE THIS SHEET NAME OVE:RCURRENT DEVICE LABELS AC DISCONNECT/BREAKER DRAWING SCALE 0000 ® N .T.5. ...`_1 NUMBER PV-G TAX MAP: 1000-031 .00-01 .00-004.000 powered by a` DUO • �_R ■ �4AOPE Warranty ®CELLS Poo s?-rkrr _ Yield Securdy BREAKING THE 20 EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE NIOS T THOROUGH=S T IPTG PROGRAINIME IN THE IIIDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TOV Rheinland. li',I`,IOV.A.Tl�iE ALf�#A/EAT--iER-E•CH`10LOG`! �1 Optimal yields,whatever the weather with excellent �J low-light and temperature behavior. n ENDURING HIGH PERPOR-NIAIiNCE ! Long-term yield security with Anti LID Technology,Anti PID I � . Technology',Hot-Spot Protect and Traceable Quality (ra.Qlm. 1 REN(E'Y41E-17.=iER RATING Z High-tech aluminum alloy frame,certified for // high snow(5400 Pa)and wind loads(4000 Pa). ti A gEDABLE lhiVEj T tLl:_N i Inclusive 25-year product warranty and 25-year linear performance warranty2. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) 'See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings Engineered in Germany C'�A' CELLS •r MECHANICAL SPECIFICATION =n-mat 74.Oin x 41.1in x 1.26in(including frame) (1879 mmx1045mmx32mm) _rr 48.5 lbs(22.0 kg) _ 0.131n(3.2mm)thermally pre-stressed glass with anti-reflection technology [ - -,_---_ 4.O-90"aib, - ac C _ Composite film _- Black anodized aluminum -- I 6 x 22 monccrystalline O.ANTUM solar half cells use) 2.09-3.98in x 126-2.36in x 0.59-0.71in �� j (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes u t49ZD250mm) 4MM2 Solar cable;(+)>-49.2in(1250mm),(-)>-49.2in(1250mm) -. ^- --^ _ 4sMa garab(DETI Aj _ ar ar Staubli MC4;IP68 -- -I I +'�e•Iszn•n;) DETAaa air ne"nnl - 0.416'Rdsmm) ELECTRICAL CHARACTERISTICS POWER CLASS --- --- - - 385 390 - 395 400 ---405 PMrr [W] 385 390 395 4CC 4135 _.., so (A] 11.04 11.07 11.10 11.14 11.17 Vice - [V] - 4519 45.23 45.27 45.30 --- ----45.34 [A] - 1C.59 10.65 10.71 10.77 10.83 VMPP [V] 36.36 36.62 36.88. 37.13 37.39 v 2:19.6 --- >_19.9 >_20.1 >_20.4--- >_20.6 .. o-O __-_ --.-_•••--•-.---PMPP .[W -288.8 -...__._292.6 296.3 - 300.1 303.8_ Isc -[A] --- 8.90 --- 8.92 8.95 8.97 9.00 ^'---._-_- ucc [VI ----42.62 --- 42.65 ---- 42.69 42.72 42.76 IMPF (Al 8.35 8.41 8.46 8.51 8.57 VMPF_ [V] 34.59 --_.._...._34.81 _ 35.03 35.25 _ 35.46 Measuremert tclerarces P_t3%;Isc;Vcc x5%at STC:ICCC VV/m2,25±2`C,AM 1.5 according to IEC 6GS04-3•7 8C VV/m2.NM07 spectrum AM 1.5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE W ----------------------------- At least 98%of nominal power during - first year.Thereafter max.0.5% - �' ________________________ degracationperyear-At least 93.5% a mal----------____-- ' of nominal power up to 10 years.At ? �/- __ least 86%of nominal power up to ------------- 25 years. ,b z „t All data within measurement tolerant- ! 'm es.Full warranties in accordance with ea [ Uxia the warranty terms of the QCELLS m "o �° eoa__ 4 ® sales organisation of your respective country. ses.c m"aa,�eaa"wn.:cwa+cao _ Typical module performance under low irradiance conditions In o eompansorto STC conditions(25°C,ICOOW/m2) TEMPERATURE COEFFICIENTS c - c a [%/K] +0.04 [%/K] -0.27 y [%/K] -0.34 _. t.I.-.._ _ra<' g-..- NMOT [°F] 109±5.4(43±3'C) --- o a o P?OPERTIES FOP, SYSTEM DESIGN! i/scam bo:a,s`j;, [V] 1000(IEC)/1000(UL) Todu'e osassircatic- Class II o m a:r;m:, 3ariss=sa .at;,:g (A DC] 20 ra r;a^ __=c1 oo a,:=i/ _:1" TYPE 2 _ m aa,Pysrr:ki. lbs/ft7i 75(3600P6/55(2660Pa _-a'sl»iodwa�amce;acus; -40°Fu to+185eF [ 1 ) ) P o �I1 c `. °11 0bs/ftCc 0r.uousCvt•/ (-40°C up to+85'C) a T3si_cad,: i/Pu 2] 113(5400Pe)/84(4000Pa) m rn 3See Installation Manual U U OUALIFICAT'ONS AND CERTIFICATES PACKAGING INFORNTATIWAI - ry UL 61730,CE-comphant, ;40'FiC• �% Quality Controlled PV-7UV Rheinland, /� " O-O 1. IEC 817132016,IEC 61730:2 60=x• -- -- -------"a- U.S Patent No.9.693,215(solar censj, Ta a d e 4 = 76.4 in 43.3 in 48.0 in 1656lbs 24 24 32 ® o OCPV Certification ongoing. Cc.nmm 1940mm 1100mm 1220mm 751kg pallets pallets modules uu enw i°nnzmn m N Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service departmert for further Informatics.cn approved:rstallaticr.arc use of this product. Hanwhe 0 CELLS America Inc. 4C0 Spectrum Center Drive,Suite 140G,Irvine.CA 92618.uSA I--S--«1 949 748 59 961 a vui L inquiry@us.c-cells.cem I «Ea www q-cells.us IIE Flush Mount System" `L J I NOW- _ -„.YYy><.:• ..� g;' t7c.�.�-_ = i�'--r..s�`_ _r:.:-s _ b Yryl'_,"_i_:�.-w.. —_� r 3 S., IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. ® Strength Tested PIE Certified All components.evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. r-_-�w create, share, and price projects. =` lie 2703 listed System F-x. 20-Y�ar Warrah Entire system and components meet l Twice the protection offered by newest effective UL 2703 standard. b', . •r - ` competitors. ' . XRID Rail XR100 Rail XRI;000 Rail Bonded Splices Aheavyweight mounting All rails use internal splices for regions with light snow.', solar mounting rail. rail for commercial projects. for seamless connections. / ~ G'spannng ^ 12,npan i capability ^ GoK+dhUingsorewe ` Moderate |oadoapab|�y ~ Extreme �ad000abi|�y ^ \au�ingversions�nr�ks ` Clear and black finish ` C����iz��ni� ^ Forms emu� ��i� ja UFOs Stopper Sleeves Grounding Lugs MicTolimverter Kits Universal Fastening Objects Snap onto the UFO to tum ys to Mount M|onrPOs\oXR bond modules 0c rails. in-to a bondedendo|omp. equipment ground. Rails. ^ Fully assembled & |ubed ^ Bonds modules Vorails ` Lovxprofile ^ Bonds devices 1on�|a ~ Sing|e, universalsize' ^ Sized to match modules ^ Single tool installation ` Kit comes assembled ' Clear and black finish - Clear and black finish ^ Mounts inany direction ^ Listed kzUL27OS FllashFoW2 Conduit Mount Bonding Hardware '-_--_ Flash and mount XR Rails Flas mount conduit, Bond and attach XR Rails with superior orjunobnnboxes. attachment. horoof st�nhmnento. ^ Twist-on Cap easoajm:� U� ~ l\mis�on«�epeases install ^ Secure m�{connections ~ T&Square Bolt options ` VNnd'dhmanrain tested ^ ��nd'dhwanrain tested ~ Slot for vordca| adjusting ~ Nut uses 7O6^socket slj,arfamoui ^ K8iUand black� 4nioh ~ Seounaa� ^or1^oonduit ^ Qeerand black�niah ^ Ansamnb|odand |ubhoo1ed p+� ��/�a3 ' - ' - - -------- - - --------' - ---- ---- Design Assistant NASCEP Certified Training Go from rough layout 0ofully / ~ ' Earn free continuing education credits, engineered system. For free. while learning more about our systems. ENPHASE, IQ8 and 108+ Microinverters Easy tok1sta Our newest 108 Microinverters are the industry's first microgrid-forming,software- • Lightweight and:compact with defined microinverters with split-phase power conversion capability to convert DC plug-rt.-play connectors power to AC power efficiently.The brain of the semiconductor-based'microinverter - power Un,€:orrr ulzieatkm is our proprietary application-specific integrated circuit(ASIC)•which.enables the (PLC)between comporterrts microinverter to operate in grid-tied or off-gr-.d modes.This chip,is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simpler to changing loads and grid events,alTetiatingconstraints on battery sizing for home txcr-A&acabffng energy systems. H3-gh;pnxh=tiY"and`eft i ty -: - P oduae power evert whert the grid is.dbwFV' ;{-:' ` } • More.than one milliorfcumulative hoEirsoftesting I _ =f CC2sstRefoas6le-iils;lfatecf Part of the Ert ase ph Energy System,IQ8 Series {Q8'Seder.Ct�rCroinverEersredefinenskiabifity Microimrerters integrate with the Enphase 10 Battery, standardswith more than one mesion cumulative Optimized focthe latest high- Enphase IQ Gateway,and the Enphase App monitoring hours otpower-on testing,enabiing.an raIndustry- anded analysis software. leading limited warranty of up to 25 years. p Ws kftbCQQIdfQirllittlg Complies with die;Pates advanced g 1d support' CERTIF!ED - Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily to 108 Series I428 Series Uliicroinverters are UL Listed as Configurable t0 support Wide Microinverters using the included Q-DCC-2 adapter PV Rapid ShtttDown Equipment and conform with cable with plug-rt-play MC4 connectors. various regulations;when installed according to range ofgrid prof es manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,108.Microinverters,and other °Only when installed with 10 System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change, meets UL 1741. "108 and 108PIus supports split phase,240V I08SP-DS-0002-01-EN-US-2022-03-17 installations only. IQ8 and I08+ Microinverters INPUT DATA(OCI 109-60-2-US 108PLUS-72-2-US Commonly used module pairings' w 235-350, 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V' 25-48 25-58 Min/max start voltage v 30/48 30/58 Max input DC voltage v 50 60 Max DC currentz[module Isc] A 15 Overvoltage class DC part II DC port backfeed current mA - 6 PV array configuration Tx1 Ungrounded array;No additional DC side protecticn required;AC side protection requires max 20A per branch circuit OUTPUT QATA IACI 108-60-2-US Peak output power VA 245 I 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range v 240/211-264 Max continuous output current A 121 Nominal frequency Hz 60 Extended frequency ange Hz 50-68 AC short circuit fault current over 3 cycles Anna 2 Max units per 20-A(L-L)-branch circuit ..-- - 16 13 Total harmonic distortion <5% Overvoltage class AC port Ill AC port backfeed current mA 30 Power factor setting 1,0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40cF to+1400F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6,9")x,302 mm(1.2") Weight .08`kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations :%::,•+ ,Yes,C. - Pollution degree PD3. Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Envircn.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741AEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C222 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufarh irer's instnx:tions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ83P-DS-0002-01-EN-US-2022-03-17