HomeMy WebLinkAbout49331-Z GyTown of Southold 10/27/2023 P.O.Box 1179 C* z 53095 Main Rd QVT oy o� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44693 Date: 10/27/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 4220 Bay Shore Rd, Greenport SCTM#: 473889 Sec/Block/Lot: 53.-6-25 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/4/2023 pursuant to which Building Permit No. 49331 dated 6/2/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Hauser,Gerard&Cecelia of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49331 10/24/2023 PLUMBERS CERTIFICATION DATED Autl Signature TOWN OF SOUTHOLD ao�su�Fnl co K o BUILDING DEPARTMENT TOWN CLERK'S OFFICE o • �h�+ SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 49331 Date: 6/2/2023 r Permission is hereby granted to: Hauser, Gerard 4220 Bay Shore Rd Greenport, NY 11944 To: Install a 20kW generator to an existing single family dwelling as applied for. Requires floodplain permit. At premises located at: 4220 Bay Shore Rd, Greenport SCTM #473889 Sec/Block/Lot# 53.-6-25 Pursuant to application dated 5/4/2023 and approved by the Building Inspector. To expire on 12/1/2024. Fees: ACCESSORY $100.00 CO-RESIDENTIAL $50.00 Flood Permit $100.00 ELECTRIC $85.00 Total: $335.00 Building Inspector o��OF SOUryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 �� • �o Jamesh -southoldtownny.gov BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Hauser Residence Address: 4220 Bay Shore Road city:Greenport st: New York zip: 11944 Building Permit#: 49331 Section: 53 Block: 6 Lot: 25 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Prime Electric INC. Electrician: Michael Hunter License No: ME-52402 SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel 200a A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200a UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 1 22kw Generator with 100amp breaker, 1 200amp transfer switch Notes: GENERATOR Inspector Signature: Date: October 24, 2023 4220 bay shore rd OF SObTyOlo1453 # # TOWN �; SOUTHOLD BUILDING DEPT. 631-765-1802 .INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: L 4,^, I e/ J In ho DATE INSPECTOR OF 50Uj�O! TOWN OF SOUTHOLD BUILDING DEPT. �oe�' 631-765-1802 X133/ INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL JOA, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ //] PRE C/O �LOAA [ ] RENTAL REMARKS: �eV�.�7mn C.e�ri�tC (,fG�vlSed r .I I s U D� a(L- I Yl�?.Qiy— C¢.j4���� �'L� 'ski )ns4Jw 4v �00 DATE 7--loy 0 oZ INSPECTOR OF 50(/ThO� * TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND. [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ v]'FINAL Y*1-- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ���� — k dv, alvAo, dl �f^ 1v� CleS oL DATE INSPECTOR 1 pF SO(/Th° qj331 qaao f3a skore . # # TOWN OF SOUTHOLD BU LDING DEPT. couo, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: V 1✓1tro a r iz DATE INSPECTOR '-- �sa .ter m LZ a 9-x CA N In Ise d 04 . 'u ods tai ro r:` R • �l ` J / n 'SII � ti •. 1 . -VI a, dki1 � � 1 I 1 Subject Building Permit 49331 From celie1110@aol.com <celie1110@aol.com> To: <lisamarieh@southoldtownny.gov> Date Oct 13 at 10:10 AM Good morning, On 7/21/2023 the inspection for my Generator showed that I was in Flood Zone AE6 and needed a new survey showing elevation and if needed, the Generator should be put on a platform. The survey showed the Generator needed to be elevated. We have brought it up to code. Please see attached survey and pictures. Please let me know if this is all ok. Celia Hauser 4220 Bay Shore Rd Greenport, NY 11944 347-804-4812 Yy t :G t , { 1 f w r , .h ��_ R�!' '^rte. �•C r � i. i' i.r(YGI��, lya� a 1. • ob Af • f €' let -t. 1 • i L t i r � . FIELD INSPECTION REPORT DATE COMMENTS �b FOUNDATION (IST) ------------------------------------ S C FOUNDATION (2ND) O ROUGH FRAMING& PLUMBING � N 9n� � r INSULATION PER N. Y-. STATE ENERGY CODE 77•a I.;Q, I" �n (o o""�IZo��et,c - YL"s �v �. �+¢.�ou_�eQ . rGIG�r►�Go� C� i FINAL ADDITIONAL COMMENTS V 2 23 ak:oE, 33s P�-Co V:e cw t !� 23 bock f e V z rn X N � H O y� y x d b H �SnfFot too TOWN OF SOUTHOLD—BUILDING DEPARTMENT =0, Gya y: Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o ao� Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtowmy.gov Date Received APPLICATION FOR BUILDING PERMIT LC6li ��i For Office Use Only MAY I qn?3 r PERMIT NO. Building Inspector: i� 8891&.9,ilvb t)aepj. Applications and forms must be filled out in their entirety. Incomplete '+OWNOFSOUTHOLD applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: April 25th 2023 OWNER(S)OF PROPERTY: Name: Celie Hauser SCTM#1000-53-06-25 Project Address: 4220 BayShore Road - Greenport NY 11944 Phone#: 347-804-4812 Email_celie1110 aol.com Mailing Address: 4220 Bay Shore Road - Greenport NY 11944 CONTACT PERSON: Name: Edward Molter Mailing Address: 700 Lakeland Avenue - Suite 2A1 - Bohemia NY 11716 Phone#: 516-790-8750 Email: egmdesign@aoLcom DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther Propane Fired Generator $ Will the lot be re-graded? Dyes R No Will excess fill be removed from premises? ❑Yes ®No 1 1 PROPERTY INFORMATION Existing use of property: Single Family 'Intended use of property: Single Family Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to - this property? ❑Yes ®No IF YES,PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made'herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(pri e): W d M Ite BAuthorized Agent El Owner Signature of Applicant: Date: 04-25-2023 STATE OF NEW YORK) SS: COUNTY�,OF ) �Uw�� being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the M (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this - o?K' day of (il I'J/ ,20a 3 O Notary Public SUSAN O'HALLORAN PROPERTY OWNER AUTHORIZATHR11YIPIL1111C.STATEOFNEWYORK egistration No.01OH6225298 (Where the applicant is not the owne Qualified in Suffolk County Commission F�lres 08.20.2 Celie Hauser residing at 4220 Bay Shore Road - Greenport NY 11944 I, do hereby authorize Edward Molter to apply on my behalf to the own of Southold Building Department for approval as described herein. �. 04-25-2023 Owner's ignature Date Print Owner's Name 2 • gUFFO(,� 'aO COGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT Cb Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 https://www.southoldtowy n .gov 1* 'l• Floodplain Development Permit Application PROPERTY INFORMATION: Flood Zone: FIRM Panel: SCTM#1000-5z3_ L-ate Address: /.9j D Shore City: C� re-e-r, Or Zip: CONTACT PERSON: Name: &ff/R Phone#:3y7_SO y_cls�a Mailing Address: Same PROJECT DESCRIPTION: SECTION A:STRUCTURAL DEVELOPMENT(CHECK ALL THAT APPLY) Type of Structure Type of Structural Activity residential(1 to 4 families) ❑New structure ❑Residential(more than 4 families) ❑Demolition of existing structure ❑ Combined use ❑Replacement of existing structure ❑Non-residential ❑Relocation of existing structure ❑ Elevated ❑Addition to existing structure ❑ Flood proofed(attach certification) ❑ Alteration to existing structure ❑Manufactured Home ❑ Other: ❑Located on individual lot ❑Located in manufactured home park SECTION B:OTHER DEVELOPMENT(CHECK ALL THAT APPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑ Connection to public utilities or services ❑ Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑Watercourse alteration (attach description) ❑ Excavation (not related to a structured development) ❑ Other development not listed (specify): By signing below I agree to the terms and conditions of this permit and certify to the best of my,knowledge the information contained in this application is true and accurate. I understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein.If revoked,all work must cease until permit is re-issued. Development shall not be used or occupied until a Cert.of Compliance is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or representative to make reasonable inspections to verify compliance. Application Submitted By(print name): 'qPU-'5Gr Signature of Applicant: �� /G = Date: 14IoDU S�ffO(j. BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o �_ Town Hall Annex- 54375 Main Road - PO Box 1179 co M Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr southoldtownhy gov — sea nda-southoldtownny.aiov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: April 25th 2023 Company Name: Prime Electric Inc. Electrician's Name: Michael L.Hunter License No.: ME52402 Elec. email: mike@primeli.biz Elec. Phone No: 631-387-5650 ❑1 request an email copy of Certificate of Compliance Elec. Address.: 1380 Broadway Avenue-Holbrook NY 11741 JOB SITE ,INFORMATION (All Information Required) Name: Hauser Residence Address: 4220 Bay Shore Road - Greenport NY 11944 Cross Street: Island View Lane Phone No.: 347-804-4812 Bldg.Permit#: 9331 email: celie1110@aol.com Tax Map District: 1000 Section: 53 Block: (o Lot: d5 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): io gook�p 'sw rK4 LurtO 7DI'(W ca:;uEo ���� �� I Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES[NNO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES F>--%JlqO Issued On Temp Information: (All information required) Service Size❑1 PhF-]3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 R2H Frame M Pole Work done on Service? Y MN Additional Information: PAYMENT DUE WITH APPLICATION BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Ze ® Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roger r@southoldtownny gov a seandCcD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN"INFORMATION (All Information Required) Date: April 25th 2023 Company Name: Prime Electric Inc. Electrician's Name: Michael L. Hunter License No.: ME52402 Elec. email: mike@primeli.biz Elec. Phone No: 631-387-5650 ❑I request an email copy of Certificate of Compliance Elec. Address.: 1380 Broadway Avenue-Holbroo,k NY 11 X41 JOB SITE INFORMATION (All Information Regyired) Name: Hauser Residence Address: 4220 Bay Shore Road - GreenportNY.11944 Cross Street: Island View Lane Phone No.: 347-804-4812 Bldg.Permit#: 4 9 3� 1 email: 'celie1110@aol.com Tax Map District: 1000 Section: 5Block: (o Lot: 0Z5 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: YES [NNO 0 Rough In El Final Do you need a Temp Certificate?: F] YES WO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# FJ New ServiceQFire Reconnect[]Flood Reconnect nservice Reconnect E]Underground00verhead #Underground Laterals 1 2 H Frame R Pole Work done on Service? 0 Y N Additional Information: PAYMENT DUE WITH APPLICATION a a KtkJ foo Wo aop t�"1 � �4rs v "I.,qt^,, LOT 152,P/0 LOT 151 AMENDED YAP Of PECONIC BAY ESTATES roi�„L nm W1,1.,Au SITUATE ARSHAMOMAQUE TOWN Of SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-53-06-25 t2•j t N SCALE 1'•20' AMa S.2027 AUGUST 2.2025 ADD ELEVATIONS O; P/0 LOT rar L • m. t�ta7+n. j3OpAO. E Os N R *4 0 Z Pro Lor rsr t A O ; to 01. Lor a.o -1A -._4 IRREGULAR CURVE SWIMS N 85'40,30" W i HERU S AND BONDS SURVEYING 100.00. s2--� S,MLE�,M yp1 we is+s)rn-Y,2 ISLAND VIEW LANE LOR 25 . aLC,ICrL 52 amNcr:1M w►a:wroc+rn wr or•rcawc e..esT.,cs 711LWm AT: QEEMMI a unrn wE IcGr d06 Ma: y-,aL MFG w T 2.202! Sent from the all new AOL app for iOS SURVEY OF LOT 152,P/O LOT 151 AMENDED MAP OF PECONIC BAY ESTATES FILE No. 1124 FILED MAY 14, 1933 ,SITUATE AROHAN40NIAQUE TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.G. TAX No. 1000-55-06-25 5GALE I"=20' - 00 APRIL 5,20-25 a P/0 LOT 151 7,535.7 s ft. 0 \� o.1-0 a C °OO\AOtt �No wPv , may` \, �3 9 0 � N fe.o. G oN CAS\ 'r-art\l�Pttutltrul,rj yr tot fvlNEW GENERATOR F� \ORS PPS b� Q,`• ,. ... �� GENERAC 20-241CW vol_ 0�yp2B on Exc4NC PAD \ p F�5� o �o''" \60, it O ,�: moi' t5- N X22 _ r.6A, P/0 LOT 151 No �— w p �. 0 4. NEW FROPANE TANK 6P A� \yto�e lz s LOT 540 , -5 ;l , — ' aa' r✓ 2�Q1 1 D O rn i \ i V3 't:7:l tLlll it4l0 �N y - Q) m 3 pP`�yLP{ s DIX = LOT 152 /- .<(D E OA'NP2`E 4'VINYL FENCEJ' . � 0 IRREOULAR CURVE PAVER L — 50' �-/- - . . — . . — . . DRIVEWAY NOTE: LOCATIONS AND EXISTENCE OF ANY EDGE OF PAVEMENT — SUBSURFACE UTILITIES AND/OR STRUCTURES NOT READILY VISIBLE, ARE NOT CERTIFIED. N 8�°4O it*, 1': d.tlJ_t IV>hY LA 30" I�•1 METES AND BOUNDS SURVEYING fr Hf.,,; APPROVED AS NOTED COMPLY WITH ALL CODES OF DATE- B.P.# 3 NEW YORK STATE & TOWN CODES n FEE: rjf 0 pn BY AS REQUIRED AND CONDITIONS OF NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE SOUTHOLD TOWN ZBA FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED SOUTHOLD TOWN PLANNING BOARD FOR POURED CONCRETE 2. ROUGH-FRAMING,PLUMBING, SOUTHOLD TOWN TRUSTEES STRAPPING, ELECTRICAL&CAULKING „# 3. INSULATION N.Y.S.DEC a 4. FINAL-CONSTRUCTION&ELECTRICAL .r MUST BE COMPLETE FOR C.-G. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ELECTRICAL INSPECTION REQUIRED FLOOD ZONA C r COMPLY WITH CHAPTER"46" FLOOD DAMAGE PREVENTION SOUTHOLD' TOWN CODE. n � GENERAC® GUARDIAN° SERIES 20/22/24 kW Residential Standby Generators Air-Cooled Gas Engine Now_ INCLUDES: Standby Power Rating G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power'" Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz G007209-0,G007210-0(Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution TM controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor , '"' t- • Standard Wi-FiO connectivity n • System status&maintenance interval LED indicators • Sound attenuated enclosure i • Flexible fuel line connector • Natural gas or LP gas operation GENERAC • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.* -- *Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. *1 https://assets.swri.org/library @us IDirectoiyOfListedProductsl I V or C QU� — Constructionlndustry/973_DoC_204_13204-01-01_Rev9.pdf c `� us LISTED tX u Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network farm produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component, appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MGI-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK°CONNECTIVITY:FREE with select Guardian Series Home standby O PWRVIEW"" TRANSFER SWITCH: The Generac PWRview Automatic Transfer generators, Mobile Link Wi-Fi allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smariphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power.The PWRview energy monitor is a simple to use and Mobile Link,users are taken care of before the next power outage. low cost tool which helps save money over the life of the generator. Included with model G007210-0. "' GENERAC @@ GENERAC' � GENERAC' PROMISE '��° * ••• � �� � VmPWR � GENERAC® 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,lightweight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) - • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 311 Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. PWRview Transfer Switch(if applicable) • PWRview energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution'"Controls • AUTO/MANUAUOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. r l GENERAC® 20/22/24 kW Features and Benefits Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours, • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 20/22/24 kW Specifications Generator Model G007038-1 G007042-2 G007D38-3 G007042-3 G007209-0 G007039-1 G007043-2 G007039-3 G007043-3 G007210-0 (20 kW) (22 kW) (20 kW) (22 kM (24 kM !Rated maximum continuous power rapacity(LP) 20,000 Watts* 22,000 Watts` 20,000 Watts* 22,000 Watts* 24,000 Wafts` Rated maximum continuous power capacity(NG) 18,000 Watts* 19,500 Watts` 18,000 Watts* 19,500 Watts* 21,000 Watts* Rated voltage 240 —] Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 ,Total—Harmonic� DistortionLess than 5% _ Main line circuit breaker - 90 amp 100 amp - 90 amp - 100 amp 100 amp ;Phase _ 1 _ Number of rotor poles — 2 -�- Rated AC frequency 60 Hz Power factor 1.0 Batt ry ere ere quirement(not included) s 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA_minimum Unit weight(lb/kg) 448/203 466/211 436/198 445/202 455/206 ;Dimensions(LxWxH)in/cm __ 48x25x29/121.9x63.5x7.3.7 Sound output in dB(A)at 23 It(7 m)with generator operating at normal load** 67 67 67 _ 67 67 Sound output in dB(A) it 23 ft(7 m)with generator in Quiet-Test'"low-speed exercise mode** 55 57 55 57 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders -- _ — 2 Displacement 999 cc ,Cylinder block -- — _ Aluminum w/cast iron sleeve - Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic ,Compression ratio --- _- —_ __ 9.5:1 �— — Starter 12 VDC ;Oil capacity including filter - Approx.1.9 qt/1.8 L ^----] Operating rpm — 3,600 1Fuel consumption Natural gas ft3/hr(m3/hr) 1/2 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) i Full Load 301(8.52) 327(9.26) 287(8.13) 306(8.66) Liquid propane k3/hr(gaVhr)[Uhr] 1/2 Load 87(2.37)[8.99] 92(2.53)[9.57] 86(2.36)[8.95] 92(2.53)[9.57] s Full Load 130(3.56)[13.48] 142(3.90)[14.77] 136(3.74)[14.15] _ 142(3.90)[14.77] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajcule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. r Mode buttons:AUTO_--�_ - — — _ _—__-_—_ Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser._�_� MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. 4 OFF -_ -_ Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard' _ Engine run hours indication_ _ Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only)_ Utility-y Voltage Loss/Return to Utility adjustable(brownout setting)— � From 140-171 V/190-216 V — - - Future Set Capable Exerciser/Exercise Set Error warning- —Standard — RuNAlarm/Maintenance logs -- _--_ --- - _ 50 events each ---_] Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). ---- ------ - - x Starter lock-out _ Starter cannot re-engage until 5 sec after engine has stopped.- --_-, Smart Battery Charger -- _ - Standard Oharger Fault/Nlissing AC warning - --`—` _�`-�� --- Standard Low Battery/Battery Problem Protection and BatteryCondition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection - Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard 'Safe Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown -Standard ------------------- ------------- ---------- --- Overcrank%Cvefspeed(@ 72 Hz)/rpm Sense Loss Shutdown__ _��-y__ ___ Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring protection _ — - Standard Common external fault capability Standard _-•- ------ ------ - - --- -- --- ---- ------ - - --- ------- -- -- - _ --- -- Field upgradable firmware _ _ Standard _ 1 *'Sound levels are taken from the front of the generator.Sound levels takeri from other sides of the generator may be higher depending on installation parameters.Rating defriitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level;and also will decrease approximately 1%for each 10°F(6°C)above 60'F(16°C). GENERAC® 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007039-1,G007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. G007043.2,6007043.3(22 kW) _ 'No.of poles 2 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Current rating(amps) 200 with Smart Management Modules(SMMs). ,Voltage rating(VAC) 120/240,10 • Electrically operated,mechanically-held contacts for fast,clean connections. Utility voltage monitor(fixed)* • Rated for all classes of load,100%equipment rated,both inductive and resistive. -Pick-up 80% -Dropout 65% • 2-pole,250 VAC contactors. !Return to Utility* Approx.13 sec • Service equipment rated,dual coil design. Exercises bi-weekly for 5 minutes* Standard • Rated for both aluminum and copper conductors. (ETL or UL listed Standard Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. �Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly 200 Amps 120/240,ie Open Transition Service Rated Height Wldth Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 GM 1 67.95 76.43 26.67 34.18 17.5 H2 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 Derr" I—wz__J PWRview Automatic Transfer Switch Features Model G007210-0(24 kW) • Integrated PWRview monitor provides real-time energy usage data through PWRview app. I No.of poles 2 ^� t Current rating(amps) 200 • Intelligently manages-up to four air conditioner loads with no additional hardware. Voltage rating(VAC) 120/240,10 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Utility voltage monitor(fixed)* with Smart Management Modules(SMMs). -Pick-up 80% -Dropout 65% • Electrically operated,mechanically-held contacts for fast,clean connections. Return tong,=— Approx.13 sec • Rated for all classes of load,100%equipment rated,both inductive and resistive. Exercises bi-weekly for 5 minutes* Standard • 2-pale,250 VAC contactors. (EL UL listed Standard • Service equipment rated,dual coil design. Enclosure type NEMA 3R ,Circuit breaker protected 22,000 • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly • Heavy duty Generac Contactor is an ETL recognized device. w' Dimensions 200 Amps 120/240,1a Open Transition Service Rated Height Width "' Hi H2 W1 W2 Depth in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 GENERAC® cm 20/22/24 kW Available Accessories _ Model# Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPacto). G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). ' of G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured (Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tank's fuel level is an important step in verifying the generator is ready t0 run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost Of the system. G007169-0-413 LT Mobile Line Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-F/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethemet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use On a single air-cooled home standby generator. Dimensions & PCs Model UPC 637.6 mm 1218 mm [25.1 In] [48.6 1n] G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727.2 mm [28.61n] G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 0 0 G007209-0 696471071511 G007210-0 696471078220 648mm 1232 mm [25.5 In] [48.5 InI LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000937814 Rev.B 07/30/2020