Loading...
HomeMy WebLinkAbout46882-Z TOWN OF SOUTHOLD ��gUfFQi�cO �y BUILDING DEPARTMENT y TOWN CLERK'S OFFICE oy,• o�� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46882 Date: 9/27/2021 Permission is hereby granted to: Williams, Kathleen 1745 Bayview Ave Mattituck, NY 11952 To: install roof-mounted solar panels on existing single-family dwelling as applied for. 1-C-).ci At premises located at: 1745 Bayview Ave U I�wv� 'I ns+AA I-e—A SCTM # 473889 Sec/Block/Lot# 106.-6-35 Pursuant to application dated 9/16/2021 and approved by the Building Inspector. To expire on 3/29/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 ui nspector OF SOUTyO� # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 4v"l INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ 'FINAL sole [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE !VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE -7-d f Z INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS 41 ,b OQ FOUNDATION(IST) N y --------------------------------- C FOUNDATION(2ND) �i . O• r J 6� ROUGH FRAMING_& l=J PLUMBING' INSULATION.PER N.Y. y. STATE ENERGY CODE n a Ivo �sIOVIL. ver FINAL ' ADDITIONAL COMMENTS COW � 0 36 z ro H O d . t�J Q44�Lxft tx��:: TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 few 4ti "' Telephone(631) 765-1802 Fax(631)765-9502 httl)s://www.southoldtowimv.!,,o Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D [ECROVE PERMIT N0, 4� 99� - Building DD Inspector: SEP 16 2029 'L!. Applications and forms must be filled out in their entirety, Incomplete applications will not be accepted. Where the Applicant is not the owner,an . T BUDLDING DFP Owner's Authorization form(Page 2)shall be completed. 'T® OF Sf9dJT PT. OLD Date: 9/13/2021 OWNER(S)OF PROPERTY: Name: Kathleen Williams SCTM#1000- 106000600035000 Project Address: 1745 BAY VIEW AVE MATTITUCK,NY 11952 Phone#: 6312758424 Email: kathywilly11@gmail.com Mailing Address: 1745 BAY VIEW AVE MATTITUCK, NY 11952 CONTACT PERSON: Name: Sung Lee Mailing Address: 45 Fairchild Avenue, Plainview NY 11803 Phone#: 5162185824 Email: permitsli@momentumsolar.com DESIGN PROFESSIONAL INFORMATION: Name: Mina Makar Mailing Address: 3096 HAMILTON BLVD.BUILDING B,&PLAINFIELD, NJ 07080 Phone#: (732)902-6224 Email: mmakar@momentumsolar.com CONTRACTOR INFORMATION: Name: Sung Lee Mailing Address: 45 Fairchild Avenue, Plainview NY 11803 Phone#: 5162185824 7 Email: permitsli@momentumsolar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Solar Panels $ 15,640.8 Will the lot be re-graded? ❑Yes ❑No Will excess fill be removed from premises? ❑Yes ONO 1 PROPERTY INFORMATION Existing use of property: S�+ , lU Intended use of property: �� �� f' 5��'✓ ¢, Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes VNo IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): rn� Lze-, ©Authorized Agent ❑Owner Signature of Applicant: Date: 1913/;x-! STATE OF NEW YORK) SS: COUNTY OF Nassau ) Sung Lee being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 13 day of 204 Notary Public Katherine Wellsburg Notary Public,State of New York Reg.No.01WE6383986 Qualified in Nassau County PROPERTY OWNER AUTHORIZATION Commission Expires December 3,2022 (Where the applicant is not the owner) I� Kathleen Williams residing at 1745 BAY VIEW AVE MATTITUCK,NY 11952 do hereby authorize Sung Lee to apply on my behalf to the Town of Southold Building Department for approval as described herein. WA-C�— 9/13/2021 Owner's Signature Date Kathleen Williams Print Owner's Name 2 .,: DD :- S�IFFOC BUILDING DEPARTMENT- Electric I pector TOWN OFSOUTHOLD SEP 1 6 2021 ' Town Hall Annex - 54375 Main Road - IfJ(Box 1179 Southold, New York 11971-095'9 DUILDIN+ DEPT. Telephone (631) 765-1802 - FAX (631)'7651 boZ S0UTT.-T0T_,D rogerr@southoldtownny.gov seand(c�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 9/13/2021 Company Name: Island Electric Corp. Name: Jeffrey Marinello License No.: 37608-ME email: jmarinello@momentumsolar.com Address: 76 Kerrigan St, Long Beach NY 11561 Phone No.: 5169032008 JOB SITE INFORMATION (All Information Required) Name: Kathleen Williams Address: 1745 BAY VIEW AVE MATTITUCK, NY 11952 Cross Street: Phone No.: 6312758424 Bldg.Permit#: email: permitsli@momentumsolar.com Tax Map District: 1 dOO Section: 106.00 Block: 06.00 Lot- 035.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of Solar Panels; Rooftop, Railless, Grid tied,21 MODULES, 7.98 KW Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required), Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect-Service Reconnected- Underground -Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection FormAs D Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) 1� Kathleen Williams residing at 1745 BAY VIEW AVE MATTITUCK, NY 11952 (Print property owner's name) (Mailing Address) do hereby authorize Sung Lee (Agent) to apply on my behalf to the Southold Building Department. V 9/13/2021 (Owner's Signature) (Date) Kathleen Williams (Print Owner's Name) Suffolk County Dept. of La tor, Licensing & Cohsumer Affairs NOME. IMPROVEMENT LICENSE = Name su'KC LEE Business Name This rA►rFif roc th'af-tnp . . .� ` •" CUA` OM T SOLAR LLC DBA bearer is duly l.i:censed PFO by the= County of suffolk License. Number: H-57578 Rosalfe Drago Issued : 10/06/2016 Commissioner Expires: 1010 /2022 - , ICountyDe-pit,, of oirs MASITE, ELECTRICAL LICEN SE aim ie, JEFFREY NAAR.fN-ELL'O n , � L LS Ibearer' sduly Di - ` the ConL of- uf1 t . , 't r* 3- 6.08 rago lslI' ® Commission 9 m-- Ex Ji � � / . YORK workers'STATE CoCERTIFICATE OF INSURANCE COVERAGE mpensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured PRO CUSTOM SOLAR LLC DBA MOMENTUM SOLAR 3096 HAMILTON BOULEVARD (732) 902-6224 SOUTH PLAINFIELD,NI 07080 Work Location of Insured(Only required if coverage is specifically limited to 1c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 27-1242539 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) First Unum Life Insurance Company TOWN OF SOUTHOLD 54375 ROUTE 25 3b.Policy Number of Entity Listed in Box"1a" SOUTHOLD , NY 11971 955431 3c.Policy effective period 11/01/2020 to 11/01/2021 4. Policy provides the following benefits: X❑ A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 10/29/2020 By Kasey Brad' ' ° (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 207-575-1519 Name and Title DBL Specialist IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200,Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or 5B of Part i has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. 1313-120.1 (10-17) 111111111111111°°11°°1°1°�°1°1°°°°°�IIIIIII Additional Instructions for Form D13-120.1 By signing this form,the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in box 1 a"for disability and/or paid family leave benefits under the New York State Disability and Paid Family Leave Benefits Law.The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices my be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Disability and/or Paid Family Leave Benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or paid family leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of NYS Disability and/or Paid Family Leave Benefits Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Disability and Paid Family Leave Benefits Law. DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits,shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however,shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first,two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (10-17)Reverse Aco 04/15/2021/® CERTIFICATE OF LIABILITY INSURANCE DATE(M1� THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Lisa MacDonald AAI CISR NAME: Brown&Brown Insurance of Delaware Valley PHONE (732)504-2001 1 FAX (732)504-2011 A/C No Et): AIC No 2000 Midlantic Dr,Suite 440 E-MAIL Imacdonald@bbdvins.com ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# Mt Laurel NJ 08054 INSURER A: Colony Insurance Company 39993 INSURED INSURER B: Zurich American Insurance Company 16535 Pro Custom Solar LLC dba Momentum Solar INSURER c: Evanston Insurance Company 35378 Momentum Home Services Holdings LLC dba Momentum Home INSURER D: 45 Fairchild Ave,Suite B INSURER E: Plainview NY 11803 INSURER F: COVERAGES CERTIFICATE NUMBER: 21-22 NY Master- REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADUL SU5R POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DDIYYYY) (MM[DD1YM LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE OCCUR R 250,000 PREMISES Ea occurrence $ MED EXP(Any one person) $ 10,000 A PACES4257993 04/21/2021 04/21/2022 PERSONAL&ADV INJURY $ 1,000,000 GENTAGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE $ 2,000,000 JECT LOC PRODUCTS-COMP/OPAGG $POLICY [gPRO- 2,000,000 OTHER; Professional Liability $ 1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 2,000,000 Ea accident JX ANYAUTO BODILY INJURY(Per person) $ BOWNED SCHEDULED BAP1873088-02 04/21/2021 04/21/2022 BODILYINJURY(Peraccident) $ AUTOS ONLY AUTOS HIRED �/ NON-OWNED PROPERIZDAMAGE $ AUTOS ONLY /� AUTOS ONLY Per accident UMBRELLALIAB X OCCUR EACH OCCURRENCE $ 5,000,000 C X EXCESS LIAB CLAIMS-MADE MKLV4EFX102983 04/21/2021 04/21/2022 AGGREGATE $ 5,000,000 DED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICERIMEMBER EXCLUDED? El NIA E.L.EACH ACCIDENT $ (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Excess Limits Clarification CGL$5M xs$1 M C MKLV4EFX102983 04/21/2021 04/21/2022 Auto$4M xs$2M DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached If more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Middle Road AUTHORIZED REPRESENTATIVE Southold NY 11971 -- — @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Additional Named Insureds Other Named Insureds Momentum Power Services LLC Momentum Roofing and Solar, LLC Momentum Roofing LLC OFAPPINF(02/2007) COPYRIGHT 2007,AMS SERVICES INC Worers' v�ItK kCERTIFICATE OF STATE Board nsa#ion 4— Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE la.Least Name&Addiess of.tnsured'(usu sUct:L utldress 0niy) fh_Business cl;'phonc Kumber of Insures Pre Cualom Sorrr'LLt ?32-902 622.1 /Jba Momentum Solar .3US-CQ Hamilion thud, Ic•NYS Unemp"ment Insurance Empfo{arReglsttaWn Numberui -.Soutt,oialtAcK N,1 WDEO Irs,,md vtiorkLocutiondI-vnured[Qrnilfreau?red'ifioveraga^'issi,vcificaffyfim"tedto 1d.Fecer-4 EmployerwoninicatlonNumtrer•3fInsured orsooialsecw* 0Dr"Oir7 'dayi`,'Om Stats.i:s_,a V11ap-dl0.Pa Cy.j Number '71242559 12_Narre,ana f&'ress of=r7tity+,Requs3tintn?rocf•ar_Govr,` ye 3a.Narrc of I n4ur+nze[*Hi,-r (EnMy Buirg LisIoJ asdhe Gerlificate Helder) Zurich Amaemn.1mueaneo Co, Town of Southold WPcFcy Nur.Tscr of[ntlry Ust d in.Box'iz' INC 44?D37-+,3 53095 Middle Road Southold, NY 11971 8c, "crud, w::n mi to deal:,:m2 iii flip Proprielor,Parinem or Exe:7,ti•ee+hosts are [ in�it,cred,lOntrclx�ht tcfltil;3i,�3nn"f9,VIriC�;'E e7ClLaetil [ an e.xcluaad or certaln parinersroffcers azcludecf. This cedirzs chat the insurance carr� ove r indicated ahin box"3"'in_surec the Nisinnss reforenc� "'I aliave in box a:for workers' compensation underthe herr York State 1164rkers',Gompensation Law,(To use this form,Aeve York(NY)must.he listed under + on the INFORMATION PAGE of the workers'compensation insurance policy)..-The Insurtlrco Car,ioror il^,liccnsed agent.wiil send' [his Certlficalu of Insurance to 9116 entity listed above as the ceTtif.cate holder in box"2"_ 'Nils the carrier tantiry'tne rti:cele holderwfthin 1e days of a poliey.br-ing cancelled ror non-payment of prerhium at within 3Gr.1rtays ff cancelle•d.for any other reason or irtite insured is other Ise rilminawd from the ooverage lndica'ed on this cerlificate prior-lo the end cr the policy elleciive period? []YES ONO itis cartificaty s:issUad ii a matter of information only and confers nu rights upon the certificate holder.This certificate does not amend, extent ora°.t3r the covwaao.sfforded by the policy listed,nor does it conrer any rights op responslbithles'boy9rid.those ocntained in the referenwd pol cy. This certificate may be'use:fas e'videnre of a 14,orkF.sm"rnmpansa5nn'cflntraci or insurance only while,the underlying policy,is in effect, Please Note:.Upon-cancellation,of-the a•rorkers'.compensation policy indicated on.this form,if the business continues to be named on a permit,,lrcense or contract issued by a certificate holder,t17e business must provide that certificate holder.with a ne%v Certificate of Workers'Compensation Coverage or other authorizes proof that.the business fs complying with the mandatory coverage requirements of the New York State Workers:.Conipensation Law: Under.penalty.af peduryr t certify-thatl aman authorizbd representative or licenseitagent cf the Insurance-carrier referenced above and-that the named insured has the.coverayu as depicted on this forst. Approvedhy: Lisa.MacDonald fFrinrmrno iraulr-vieed raprese^LaU,e or I�ctmej anenr'c:insurance t:afrer? Aj;pruvud by: L"m_tlP ,r,r a �-- 4/8/2021 (snmturet {care) Ti11n: Account Executive Telephone Number of autiiwized representative or,licensed agent ohinsurarlce carile.:.732-504-200'1 Please.Note:-Only insurancecarriers and their-licensed agents are authorized to Issue Form C-105.2-.Insuranco brokers are Nod' authorized to issue.it. C-105.2(9-15) >, )iv/.wcb.ny.gpv Workers` Compensation Law Section 57, Restriction on issue of permits and the.entering.into contracts unless compensation Is secured. 1. I'hc head of�a.state cr municipal department, board, comrrmissicri or office auftfted,or required bylaw tc issue any permit for or in connection villh any,work involving the employment of employees in-a hazardous employment defined by this.chaptc-c, and notNithstanding any general or special-statute requiring.or authorizing-the issue,of such permits, shall net issue such perrnil unless proof duty subscribed by a,n insurance carrier is produced In a-.fom)satisfactory to Me chair, that compensation for all ornplayee.� has been secured .as provided by this chapter. teething iierein, however, shall be Toric-trued as creating any liability on the part of such state dr municipal department; board, corr,mission or off'jcc to pay any compensation to any-such employee if so eniplo;ved. 2. Tie head OfI2 state or municipal department, hnard, commission.or office authtrized or required by law to enter into anv contract fnr.zr in connection vwith any vxrH Involving the:employment of em;iloyeesAa a hazardous employment defined by this chapter, notvdthstandlug any-'general ur spedal statute requiring or authorizing any such contract,shall notenterInto any such contract unless proz)f duly subscribed by-an Insurance cameras produo-ads in a forrn'satisfnctflry to(lie chair, that compensation for-all employees has been secured as pro;.vidod by:his chapter. G-105.2(9-451 REVERSE Mina Makar Engineer-PE Mina Makar Engineer-PE Pro Custom Solar LLC 732-902-6224 Pro Custom Solar LLC 732-902-6224 3096B Hamilton Blvd August 26,2021 3096B Hamilton Blvd August 26,2021 South Plainfield,NJ 07080 South Plainfield,NJ 07080 Re:Proposed Photovoltaic Solar Panel Installation Gravity Load Calculation Criteria Kathleen Williams Structural Design Loads per ASCE 7-16 1745 BAY VIEW AVE MATTITUCK,NY 11952 Dead Loads=10 psf+2.6 psf(new solar panels)=12.6 psf Roof Live Load=20 psf Dear Plan Reviewer: Ground Snow Load/Live Load=25 psf Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation Wind Load Calculation Criteria when installed in strict compliance with the manufacturers printed instructions. Wind Loads per ASCE 7-16,Ch.30.4 Regarding the solar panel array installation on the above referenced project please note that an inspection was Design wind pressure determined by Eq.29.4-7: performed by a representative of the Architect/Engineer of Record,and analysis of the existing structure was Zone 1=-23.6 psf Roof Slope=45 degrees Roof Mean Height=15 ft conducted.There is adequate structural capacity for the installation of the array with the following recommendations: Zone 2=-30.7 psf Basic Wind Speed=130 mph 1.The array will be installed on the existing roof.The roof framing is constructed of 2"x8"wood rafters @16"o.c. Zone 3=-34.6 psf Exposure=B spanning 89"with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./Sf.overall to the roof.The existing structure is sufficient to support the new loads associated with the additional weight&wind Per section 2.4.1,ASD combo=D+0.6W: resistance.No additional structural support is required for the roof structure. Zone 1=2.6 psf+0.6(-23.6 psf)_-11.6 psf Zone 2=2.6 psf+0.6(-30.7 psf)_-15.8 psf 2.The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed Zone 3=2.6 psf+0.6(-34.6 psf)_-18.2 psf instructions.The attachment system shall be UL 1703 approved tested.Provide 6 mil.vapor barrier between dissimilar metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as Check Attachment to Wood Rafter specified by the system manufacturer's installation manual.The panel angle shall match the roof slope.Reference Use 5/16 dia.Lag screw w/3"embedment into 2 in.wide roof rafter summary table below: Lag Screw Spacing: Lag Screw Tributary Area: Roof Type: Shingle Fastener Max Spacing(in.) Zone 1= 48"o.c.max Zone 1=(48"o.c.max)^2/144=16 SF Attachment System: "ROOFMCH"®"RT"Attachment Systems Wind Zone 1 Wind Zone 2 Wind Zone 3 Zone 2= 32"o.c.max Zone 2=(32"o.c.max)^2/144=7.11 SF Fastener Info: min.5/16"x 4"long stainless-steel lags with a min. 48 32 32 Zone 3= 32"o.c.max Zone 3=(32"o.c.max)^2/144=7.11 SF embedment of 3"into the rafters 3.Solar Modules shall be UL-1703 rated.Refer to manufacturers specifications sheets. Lag Screw Forces: W=266lb/in(Table 12.2A,2015 NDS) 4.Positive drainage of the system shall be so as not to void the existing roof warranty. Zone 1=11.6 psf x 16 SF=186 lb < W', OK Cd=1.6(Table 2.3.2,2015 NDS) 5.All aspects of the installation shall comply with the 2020 Residential Code of New York State,ASCE-7-16,2017 Zone 2=15.8 psf x 7.11 SF=112 lb < W', OK Ct=1(Table 2.3.3,2015 NDS) National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by Zone 3=18.2 psf x 7.11 SF=129 lb < W', OK W'=W x embed x Cd x Ct law. W'=266 lb/in x 3 in.x1.6 x 1=1276.8 lb 6.Please refer to the attached structural calculations. If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. OF NEW y P O M4�q�'p'� Mina Makar,P.E. r- W NY.Lic.No. 104468 ti 104468 AR�FESSIONa� 2D, SEP 1 5 2021 O.E�1siIJ�r�l'v,UsS�7-,�7�..5'_k,L,��r,e�•g Y PLAN KEY SYSTEM INFORMATION THE RESPONSIBLE LICENSED DESIGN PROFESSIONAL SHALL PV-1 COVER PAGE MODULE HANWHA Q.PEAK DUO BLK ML-G9+380 PROVIDE A SIGNED AND SEALED LETTER CERTIFYING THE PV-1(2) COVER PAGE CONT. INVERTER ENPHASE IQ7PLUS-72-2-US INSTALLATION WAS INSPECTED AND CONFORMS TO THE momentum PLANS AND REQUIREMENTS OF THE 2020 NYS BUILDING PV-2 PANEL LAYOUT RACKING ROOFTECH RT-APEX CODE AND 2020 NYS RESIDENTIAL CODE. THIS INSPECTION SOLAR PV-3 ELECTRICAL AND CERTIFICATION LETTER SHALL BE PERFORMED AFTER SYSTEM SIZE (DC) 7.98 KW INSTALLATIONS ARE COMPLETED AND SHALL BE SUBMITTED PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PV-4 EQUIPMENT LABELS TO THE BUILDING DEPARTMENT PRIOR TO SCHEDULING OF 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,Ni LOCATION 41.0033266,-72.5485577 FINAL INSPECTION. (732)902-6224,MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING THE UL CERTIFICATE OF ELECTRICAL INSPECTIONS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT PRIOR TO �OF NEW GENERAL NOTES: SCHEDULING OF FINAL INSPECTION. ���� A• �Y0 P 4 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS ��� FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 2020 NYS BUILDING * 7k CODE AND 2020 NYS RESIDENTIAL CODE, NEC 2017 AND ALL LOCAL CODES & ORDINANCES. n AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ON BOTH SIDES OF THE ROOF. NOT FEWER THAN TWO PATHWAYS, ON SEPARATE ROOF PLANES FROM tI' LOWEST ROOF EDGE TO RIDGE AND NOT LESS THAN 36 INCHES (914 MM) WIDE, FO 104468 SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE A/QQ�res`ONQ� PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE G J WITH A PHOTOVOLTAIC ARRAY, A PATHWAY NOT LESS THAN 36 INCHES WIDE (914 MM) SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME MINA A.MAKAR,P.E.NY LICENSE#104468 732-902-6224 3096B HAMILTON BLVDSOUTH PLAINFIEL ,NJ 07080 ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCUFOR SOLAR INSTALLATION SPANS STRADDLING THE SAME AND ADJACENT ROOF PLANES. ATTACHMENTS TO MEEKLOCAL AND STATE BUILDING CODE & COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. CUSTOMER WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR INFORMATION PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER BILL OF MATERIALS KATHLEEN WILLIAMS-MS85421 SYSTEMS. NON SH MODULES 21 1745 BAY VIEW AVE ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT SH MODULES 0 MATTITUCK, NY 11952 INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A 6312758424 PLUMBING PERMIT AND INSPECTION. INVERTERS 21 JURISTICTION:SUFFOLK INVERTER PLACEMENT: ROOFTECH BASE 71 UTILITY: PSEGLI MID CLAMP 48 UTILITY ACCT#: UTILITY METER#: SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL END CLAMP 17 LOCATED ON THE BACK SIDE OF EACH MODULE. PV SYSTEM END SPLICE 6 BUILDING REVIEW NOTE: END FLOATING SPLICE 7 INFORMATION TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR MID FLOATING SPLICE 7 SYSTEM SIZE(DC):7.98 KW SYSTEM SIZE(AC):6.195 KVA MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED 21 MODULES: HANWHA Q.PEAK DUO BLK IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. SKIRTS 5 ML-G9+380 THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT ENPHASE COMBINER BOX 1 (SAFE HARBOR MODULES:0) RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW 21 INVERTERS: ENPHASE IQ7PLUS-72-2-US YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S 40A BREAKER 1 PROJECT INFORMATION BELIEF AND INFORMATION, THE WORK IN DOCUMENT IS: INITIAL DATE:8/27/2021 DESIGNER:AKL 1. ACCURATE REV: DATE: DESIGNER: 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE REV: DATE: DESIGNER: SUBMISSION. 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO COVER PAGE THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE RESPONSIBILITY OF THE LICENSEE. Pv_ 1. ALL WIND DESIGN CRITERIA ARE FOR LOW SLOPE ROOFS, GABLE AND HIP ROOFS0 CONSIDERED FROM AN ANGLE OF MIN.9.5 a(12)TO MAX.45° (12)NOT TO EXCEED standardThe . momentum 30'MEAN ROOF HEIGHT ATTACHED WITH FASTENERS AS SPECIFIED BY THE PEX MANUFACTURER. _dLkajj.S Installation Item&Part Number SOLAR 2. SPAN TABLES ARE DERIVED FROM MECHANICAL LOAD TESTS PERFORMED BY THE Wenost y • RT-APEX Base(RT3-00-AXBK) Install Base and End clamp Slide In Mounting MANUFACTURERS INDEPENDENT TESTING AGENCIES ON BEHALF OF THE MANUFACTURER. ' ,• w ♦ PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR " `"' s 3096 HAMILTON BLVD.BUILDING B,&PLAINFIELD,NJ ;� y 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 �-_`� r,._-'._4"''`''��r�:��_�' RT-Apex Base;24 ea. (732)902-6224,MOMENTUMSOLAR.COM .�—�.—== SD5-60 Screws;48 ea. 4. ALL ATTACHMENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH '- *- _'' AdditonalRT-Butyi;l2aa. PROFESSIONAL ENGINEERING - _ -+�—. MANUFACTURERS PRINTED INSTRUCTIONS. E r'"'t I' Middle clamp Middle Clamp(RT3-02-UWBK) (' '�'�- -;.,r;I: ,P',• "�` Middle FloeUng Splice(RT3-02-UMFSBK) Middle Clamp Splice(RT3-02-UMSBK) 0 r L all 4 F.: Middle damp;12 ea. End Clamp Splice (RT3-02-UEF End Floating Splice(RT3-02-UEFSBK) 7C )f Aaii'I * EX End Clamp Splice(RT3-02-UESBK) Skirt and End Splice Skirt and End clamp �� End Clamp;12 ea. RT-APEX Skirt(RT3.03-SK80BL) c s o --- - --- Universal Clamping / Slide In Mounting F� 104468 One Step Leveling / Integrated Flexible FlashingOne step leveling ! SSIONP RT-Apex Skirt 80inch;8 e Proven PV mounting since 1994 X (1oe�ma.> Ma[edal Descd don ATTACHMENT SPACING EXCEED MANUFACTURERS SPECIFICATIONS FOR WIND LOADS �� �� (75mm) �5e MINA A.MAKAR,P.E.NY LICENSE#104468 732-902-6224 - ICC Clamps Anodized aluminum 30968 HAMILTON BLVDSOUTH PLAINFIELD,NJ 07080 AS PER ASCE 07-16. RISK CATEGORY II TOPOGRAPHIC EFFECTS B,C,&D AND ROOF ee 1 sk rt ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND WIND ZONES 1,2,&3. ROOF ZONES 2&3 ARE WITHIN 48"OF ANY OUTER EDGE, HIP, 'v f �'' o o Hardware Stainless steel AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& .-- ICC ESR 3575 - Flexihle Flashing RT Butyl(ICC ESR 3575) Intertek ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE RIDGE, OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT. 5'_ k � 25 YearPAT PENDINGrranry COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR 3 1/2" 90mm) ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ® Roof ® • _ LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. _ Roof Tech Inc. GUTTER GUTTER The Standardlor Waterproof Flexible Flashing Since 1994 www.roof-techius ••wwW.roof-tech.us: ififo@roof-tech.us 10620 Treena St.Suite 230,San Diego,CA,92131 ". r LL ® T 10 0 LU CUSTOMER ��Q ® INFORMATION © 2 ® RIDGE RIDGE O KATHLEEN WILLIAMS-MS85421 ® ® ©y ® 1745 BAY VIEW AVE MATTITUCK, NY 11952 LU 6312758424 JURISTICTION:SUFFOLK UTILITY: PSEGLI ® ® GUTTER © GUTTER © STRUCTURAL STATEMENT: UTILITY ACCT#: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE UTILITY METER#: ROOF WIND ZONES AS PER IRC R301.2(7) NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEN PV SYSTEM ROOF ZONES 2&3 ARE 48"FROM OUTTER ROOF EDGES, INCLUDING UPLIFT&SHEAR.EXISTING RAFTER SIZES & RIDGES, HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES DIMENSIONS CONFIRM TO 2020 NYS BUILDING CODE AND INFORMATION BELOW 30'-0"MEAN ROOF HT. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA RESIDENTIAL CODE TABLE R802.5(1)-RAFTER SPANS. SYSTEM SIZE(DC):7.98 KW SYSTEM SIZE(AC):6.195 KVA TABLE R301.2(1) MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW 21 MODULES: HANWHA Q.PEAK DUO BILK YORK STATE CODE REQUIREMENTS FOR THE DESIGN CRITERI ML-G9+380 GROUND SNOW LOAD(LBS/SF) 25 OF THE TOWN. (SAFE HARBOR MODULES:0) SPEED (MPH) 130 21 INVERTERS: ENPHASE IQ7PLUS-72-2-US TOPOGRAPHIC EFFECTS B PROJECT INFORMATION TOTAL WEIGHT OF PV MODULES AND RAILS 878.85 LBS SPECIAL WIND REGION NO INITIAL DATE:8/27/2021 DESIGNER:AKL TOTAL NUMBER OF ATTACHMENT POINTS 65 WIND BORNE DEBRIS ZONE 2 REV: DATE: DESIGNER: EIGHT PER ATTACHMENT POINT SEISMIC DESIGN CATEGORY C HANWHA Q.PEAK DUO BILK ML-G9+ 380 REV: DATE: DESIGNER: 380 WATT MODULE TOTAL SURFACE AREA OF PV MODULES 380.94 SQFT CLIMATE ZONE 4A 72(4EE DATASHEET1f 6" COVER PAGE DISTRIBUTED WEIGHT OF PV MODULE ON ROOF 2.31 LBS./SQFT WIND EXPOSURE CATEGORY B PV- 1 ( 2) SCALE: 1/8" = 1'-O" ROOF MODULE COUNT TILT AZIMUTH SHADING LANDSCAPE MAX SPAN PORTRAITMAXSPAN ROOF AREA 1/2/3) (ROOF AREA 1/2/3) R1 21 45° 167° 72% 72/72/52 43/43/31 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ (732)902-6224,MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING cl r � n GROUND ACCESS (TYP) �`� e 104468w` FIRE SETBACK A,r�FEsslO`�P� (18" VENTILATION, O 36" ROOF ACCESS) MINA A.MA R,P. ESE#1 (732)— — 4 (TYP) ENGIN 3096B HAMILTON TER ATTACHED D HASIELD,NJ 07080 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR O ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. 3'-0" 1'-6" i CUSTOMER INFORMATION KATHLEEN WILLIAMS-MS85421 1745 BAY VIEW AVE MATTITUCK,NY 11952 a i a 6312758424 ° W 3'-0° j ; j I y I I i j SYMBOL LEGEND JURISTICTION:SUFFOLK J > MSP s ! 1 R1 E UTILITY: PSEGLI Q �n I o O O I I I MSP MAIN SERVICE PANEL ® CHIMNEY UTILITY ACCT#: UTILITY METER#: t ff � II a LU LLi ,~z, ) k 4 i j i i y 9 I i y I i SP SUB—PANEL SKYLIGHT LU M ! 2'-4" ❑ j ! y � I t ; l 6 y ' i f j O UTILITY METER VENT INFORMATION GUTTER SYSTEM SIZE(DC):7.98 KW 10'-61"2AC COMBINER BOX/AC SYSTEM SIZE(AC,): 6.195 KVA CB DISC FC FDO PIPE VENT ( ) 21 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+380 uDc UTILITY DISCONNECT @ FAN (SAFE HARBOR MODULES:0) EXISTING TRENCH 21 INVERTERS: ENPHASE IQ7PLUS-72-2-US LC LOAD CENTER SATELLITE DISH PROJECT INFORMATION N3R NEMA 3R BOX W/ENVOY—S ® FIRE SETBACKS INITIAL DATE:8/27/2021 DESIGNER:AKL REV: DATE: DESIGNER: CB COMBINER BOX GROUND ACCESS REV: DATE: DESIGNER: FRONT OF RESIDENCE BAY VIEW AVE PF PERFORMANCE METER PITCH DIRECTION PANEL LAYOUT MODULE PV- 21 HANWHA Q.PEAK DUO BLK ML-G9+380 380W MODULES PAIRED WITH 21 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS momentum SOLAR BRANCH CIRCUITA 11 MICRO-INVERTERS PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR BRANCH CIRCUIT B EXISTING 200A MAIN 3096 HAMILTON BLVD.BUILDING B,&PLAINFIELD,NJ 10 MICRO-INVERTERS SERVICE PANEL 240 V (732)902-6224,MOMENTUMSOLAR.COM 9189L AC PROFESSIONAL ENGINEERING DISCONNECT MAIN BREAKER:200A + - - } - ENPHASE 80A AC �,Of NEW COMBINER BOX �Q� P A. Mq,�yp�,�, W/ENVOY IQ 200A f f9 19 GRID g 8 aoA C7 � ROOF 10A/15AGBREAKER ND BU JUNCTION (MANUFACTURER 89L AC POWER UTILITY �� 104468 DISCONNECT - GROUND METER FD BOX SUPPLIED. ENVOY) �Q A TERMINATIONNSTALLLED ON 1 2A-B 20A BREAKER(A)(PV) 3 �OrESS1O�r� END OF CABLE 20A BREAKER(B)(PV) !0% RULE MINA A.MAKAR,P.E.NY LICENSE#104468 732-902-6224 ,US RATING x 1.2) - MAIN BREAKER = BACKFEED AVAILABLE ENGINEERING LEITER DHA HAS ISPECIFELD,NJ 07080 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE �OOA x 1.2 - 200A - 40A BACKFEED AVAILABLE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ELECTRICAL NOTES: 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 10.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C UNLESS NOTED LABELING AS PER 690.56(C)(3).AC VOLTAGE AND SYSTEM OPERATING ELECTRICIAN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM CURRENT SHALL BE PROVIDED AS PER 690.52. PRO CUSTOM SOLAR DBA MOMENTUM SOLAR MARINEL ,(732)902-6224 ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. EQUIPMENT DATA SHEET 11. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS-BRANCH 30 6REY HAMILTON BLVD.BUILDING B,SOUTH PLAINFIELD,NJ 07080 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 8.GROUNDING CONDUCTOR RUN WITH PHASE CONDUCTOR IN CIRCUITS AND NOT PV SOURCE CIRCUITS 690.6. CUSTOMER PARAGRAPH C). THE SAME CONDUIT. 12.ALL GROUNDING SHALL COMPLY WITH 690.47(A)IN THAT THE AC INFORMATION 3. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST 9.SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC MODULES SHALL COMPLY WITH 250.64. BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS WILL HAVE LOWER CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER,JUNCTION 13.NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS KATHLEEN WILLIAMS-MS85421 DESIGN CURRENT THAN THE ONE SHOWN. BOX, DISCONNECT.AND COMPILES WITH 690.6-NO DC. AC MODULE SYSTEM 690.6,690.17. 1745 BAY VIEW AVE 4. THIS SYSTEM COMPLIES WITH NEC 2017 DISCONNECT AND ASSOCIATED DC CABLING ARE REQUIRED. 14.WHERE APPLICABLE, INTERCONNECTION SHALL COMPLY WITH MATTITUCK, NY 11952 B9L VISIBLY BROKEN, LOCKABLE,LABELLED,GANG OPERATED LOAD BREAKER. 705.12(A)OR 705.12(B)AS PERMITTED BY 230.82(6) 6312758424 JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#: UTILITY METER#: PV SYSTEM INFORMATION SYSTEM SIZE(DC):7.98 KW SYSTEM SIZE(AC):6.195 KVA Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire 1 MODULES:HANWHA Q.PEAK DUO BLK Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type L-G9+380 SAFE HARBOR MODULES:0) 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 11 1.21 1.25 16.64 12 AWG Trunk Cable Z1 INVERTERS: ENPHASE IQ7PLUS-72-2-US 2A 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 11 1.21 1.25 16.64 08 AWG THWN-2 PROJECT INFORMATION 213 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 10 1.21 1.25 15.13 08 AWG THWN-2 INITIAL DATE:8/27/2021 DESIGNER:AKL REV: DATE: DESIGNER: 3 1" PVC 3 08 AWG THWN-2 75°C 50 0.96 1 48.00 21 1.21 1.25 31.76 08 AWG THWN-2 REV: DATE: DESIGNER: ELECTRICAL PV-3 AG LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY J • • 12 AC CONDUITS ENCLOSURES/WALLS/ PARTITIONS/CEILINGS FLOORS OR NO MORE THAN � momentum 10, SSOLARrWARNINGPHOTOVOLTAIC-- EQUI ED WITH D ° °• 1 COMBINER BOX 1 AT ANY COMBINER BOX PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLA R �y _ PHOTOVOLTAIC POWER SOURCEw ,_ 4` 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ =" (732)902-6224,MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING AWARNING . } l � LII/ C ELECTRICAL SHOCK HAZARD '" 1 '4��''� �P A• 44 �P TERMINALS ON BOTH LINE AND 1 JUNCTION BOX 1 AT ANY JUNCTION BOX LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 1� " DISCONNECTPV SYSTEM AC _ D Z RATED s "oOUTPUT CURRENT A ' = �`� 104468 ELECTRICAL SHOCK HAZARD NOMINALOPERATING TERMINALS ON BOTH LINE AND - SIAC ON�' 1 • LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ___ MINA A. A R,P.E.NY LICENSE# (732)-902-6224 1 OF EACH AT FUSED AC !' _ = 30968 HAMILTON BLVDSOUTH PLAINFIELD,NJ 07080 &CAUTION DISCONNECT ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND ® .+,: AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& 1 AC DISCONNECT COMPLETE VOLTAGE AND 7 - ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE CURRENT VALUES ON COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR • • I ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A • SUPPLIED FROM • ON-SITE DISCONNECT LABEL� I LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. ALS SOLAR GENERATION RAPID SHUTDOWN SWITCH AC SYSTEM DISCONNECT FOR SOLAR CUSTOMER ED 1 PV METER 1 AT PV METER SOCKET AND _ Z a ==I INFORMATION SOCKET ONE DIRECTORY PLACARD KATHLEEN WILLIAMS-MS85421 1745 BAY AVE A WA RN�I N G,� /, ! _ MATTITUCK,INY/1952 _=----- - 1 UTILITY METER 6312758424 _ DUAL POWER SOURCE / JURISTICTION:SUFFOLK SECOND SOURCE I$ 1 AT UTILITY METER AND ONE t emirs . I.' '�e PHOTOVOLTAIC SYSTEM , DIRECTORY PLACARD UTILITY: PSEGLI UTILITY ACCT#: SOLAR PV SYSTEM EQUIPPED mUTILITY METER#: WITH RAPID SHUTDOWN -' � =WARN PV SYSTEM TURN RAPID SHUTDOWNY--^t ----- ^~«-'--- - y--.•r - INTERCONNECTION SWITCH TO THE•OFF "Y-S}°..�.`.•' ':... r- .,N.,+A.*-^r.a%e, :1._,y�. 1 PosmONTOSHUTDOWN _.�W DUAL POWER SOURCE- --s POINT O INFORMATION PV SYSTEM AND REDUCE .St+ 'S.'w'.i'^'=3'- SHOCK HAZARD IN ARRAY SECOND-SOURCE IS F :Yta• 'eMMY'B;�:i°t"'' '?�NYeA'ao"'adK� + �= _ _ _ _ J PHOTOVOLTAIC:SYSTEM ' - SYSTEM SIZE(DC):7.98 KW G I3� :�^�¢ ?. --` ? _r_-. SYSTEM SIZE(AC):6.195 KVA 1 OF EACH AT BUILDING �T 21 MODULES:HANWHA Q.PEAK DUO BLK INTERCONNECTION POINT AND C ML-G9+380 WARNING:INVERTER OUTPUT CONNECTIQN' ONE DIRECTORY PLACARD _ I (SAFE HARBOR MODULES:0) BACKFEED PANEL DO NOT RELOCA_ .'- IS:-,'T' 1 I �_^__ 21 INVERTERS: ENPHASE IQ7PLUS-72-2-US OVERCURRENT DEVICE, ;;'r r j __ PROJECT INFORMATION INITIAL DATE:8/27/2021 DESIGNER:AKL =MINAL OPERATING AC VOLTAGE: 1 ( - NOMINAL OPERATING AC FREQUENCY:60HZ REV: DATE: DESIGNER: 1 POWER: 1VA REV: DATE: DESIGNER: CURRENT:MAXIMUM AC � - 1 AC CURRENT PV -- •_ MODULES EQUIPMENT LABELS MODULEAC -. . 1 © BACKFEED PV-4 RT- -APEX RT The PEX standard for rail-lessPV mounting Installation Item & Part Number The most advanced Raff-fess & Self-flashing PV Mounting System� -N Install Base-and End clamp Slide In Mounting RT-APEX Base(RT3-00-AXBK) . ref g— RT-Apex Base;24 ea. _- _ _ - SD5-60 Screws 48 ea. Additional RT-Butyl; 12 ea. Middle clamp djL =`` Middle Clamp(RT3-02-UM-BK) Middle Floating Splice(RT3-02-UMFSBK) Middle Clamp Splice(RT3-02-UMSBK) SGsii-1 �� � 1,� .� _ �•,'M1�•.;,:'.,' ``' rte.. � �`� 0101-461 �,�:'}."T:'r�i. .�+�-''fit'<..;�...�w,n��,`s��:3�'� � f ••:_ �•^ �¢•w�,y; .. , p ,�'k.;��. =" s ,i. ter•, - J Middle clamp; 12 ea. ��;� �t4' End Clamp(RT3-02-UE-BK) End Floating Splice(RT3-02-UEFSBK) RT— End Clamp Splice(RT3-02-UESBK) Skirt and End Splice Skirt and End clamp A End Clamp; 12 ea. RT-APEX Skirt(RT3-03-SK80BL) Universal Clamping / Slide In Mounting One Step Leveling / Integrated Flexible Flashing One step leveling RT-Apex Skirt 80inch;8 ea. Proven PV mounting since 19943 (108/ „ mm) Material Description (75mm) Base ICC �� Clamps Anodized aluminum ETV rc US MEJa Skirt Hardware Stainless steel f ICC ESR 3575 Intertek V Flexible Flashing RT Butyl(ICC ESR 3575) 25 Year Limited Warranty 3 1/2" (90mm) PAT PENDING ® Roof Roof Tech Inc. The Standard for Waterproof Flexible Www.r•• • Flashing.• 10620; - 230 San Dieao. CA 921311► 858.935.6064 "" Rev.03-2030 powered by MECHANICAL SPECIFICATION ID U O -- Format 72.4in x 40.6in x 1.261n(including frame) n.•asw,,.,n _ -- - (1840 mm x 1030 mm x 32 mm) .=raaee..m u^'m^^^• Weight 43.0Ibs(19.5kg) Front Cover 0.11 in(2.8 mm)thermally pre-stressed glass with anti-reflection technology 4•a�m ure'l45m rim. - -- Back Cover Composite film asem..N Frame Black anodized aluminum ® o.'awomml Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60 mm x 15-18 mm),IP67,with bypass diodes Cable 4mmz Solar cable;(+)z472in(1200mm),(-)z472in(1200mm) + .;.Z.a 'DiYuj Connector _ Staubli MC4;IP68 __ _ _ _ - I I -osr,=1 4 BE'n45mN IIIc�T lObmmy . • : • ELECTRICAL CHARACTERISTICS POWER CLASS 365 370 375 380 385 • MINIMUM PERFORMANCE AT S TANDARD TEST CONDI(IONS,5 rC'(POWER TOLERANCE+5W/-OW) • • Power at MPP' Pum [W] 365 370 375 380 385 E Short Circuit Current' Isc [A] 10.40 10.44 10.47 10.50 10.53 � F51R ® E Open Circuit Voltage' yo. _ IV] 44.93 44.97 45.01 45.04 45.08 • Q Current at MPP I­ [A] 9.87 9.92 9.98 10.04 10.10 :55 - TOP BRAND PV� Voltage at MPP Vu„ IV] 36.99 37.28 37.57 37.85 38.13 01-010011, Efficiency 4 [%] 219.3 219.5 219.8 220.1 220.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT=_ Warranty Q CELLS Power at MPP PM Iw] 273.3 277.1 280.8 284.6 288.3 �j Productapedom,a Yield Security E Short Circuit Current Isc [A] 8.38 8.41 8.43 8.46 8.48 Open Circuit Voltage Voc [V] 42.37 42.41 42.44 42.48 42.51 BREAKING THE 20%EFFICIENCY BARRIER Currentat MPP IMm [A] 776 7.81 7.86 7.91 796 Q.ANTUM DUO Z Technology with zero gap cell layout Voltage at MPP Vu IV] 35.23 35.48 35.72 35.96 36.20 boosts module efficiency up to 20.6%. 'Measurement tolerances Pu„z3%;Isc;Voc±5%at STC:1000 W/m=,25i2'C,AM 15 according to IEC 60904-3.2800 W/m2•NMOT,spectrum AM 15 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE INNOVATIVE ALL-WEATHER TECHNOLOGY 8g °° -.� Atleast98%of nominal power during 7_ __T-----T-----r - -r O timal yields,whatever the weather with excellent P Y Ww first year.Thereafter max.0.5% low-light and temperature behavior. LLo .. ----- -- ----- degradation per year.At least 93.5% w� of nominal power up to 10 years.At ..n >z ____________ least 86%of nominal power up to - HIGH PERFORMANCE o - -- 25 years. .. __ _____ ------ ENDURING ____ Lon -term yield securitywith Anti LID Technology,Anti PID s V � g gY o All data within measurement toleranc- Technology',Hot-Spot Protect and Traceable Quality Tra.QT" es.Full warranties in accordance with �� the warranty terms of the O CELLS m � =a0 4O0 BW IRR4a14NCE[W/mil sales organisation of your respective r EXTREME WEATHER RATING ° e ° country. �M ..° sod« m4 ve s Typical module performance under low irradiance conditions In High-tech aluminum alloy frame,certified for comparison to STC conditions(25°C,1000W/m2) high Snow(6000 Pa)and wind loads(4000 Pa). TEMPERATURE COEFFICIENTS A RELIABLE INVESTMENT Temperature Coefficient of Ise a [%/K] +0.04 Temperature Coefficientof Voc ]I [%/K] -0.27 QY Temperature Coefficient of P�,,,, Y [%/K] -0.35 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) Inclusive 25-year product warranty and 25-year Vey o l rr linear performance warrantyz. PROPERTIES FOR SYSTEM DESIGN u STATE OF THE ART MODULE TECHNOLOGY Maximum System Voltage V_ [V] 1000(IEC)/1000(UL) PV module classification Class II 'o I _ Q.ANTUM DUO combines cutting edge cell separation Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 0 Max.Design Load,Push/Pull' [lbs/ftq 84(4000Pa)/55(2660Pa) Permitted Module Temperature -40°F up to+185°F p and innovative 12-bulbar design with Q.ANTUM Technology. on continuous Duty (-40°C up to+85°C) Max.Test Load,Push/Pulls [lbs/ft=] 125(6000Pa)/84(4000 Pa) I APT test conditions according to IEC/TS 62804-1:2015,method B(-1500V,168h) 'See Installation Manual See data sheet onrear for further information. QUALIFICATIONS AND CERTIFICATES PACKAGING /AND TRANSPORT INFORMATION t1L 61730,CE-compliant IEC 612167019, IoJV�J •oN`IVJ L^a�l��J r'0"] dpHC� IEC 617307018, ®R.a ♦ ♦ OTHE IDEAL SOLUTION FOR• u.s.PatantNp a.eaa.zls (` �•.` .o.�,d Horizontal 74.4in 42.5in 47.6in 14581bs 28 24 32 epackaging 1890mm 1080mm 1208mm 661kg pallets pallets modules Rooftop arrays on m nu:mr» m residential buildings Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Y KEELS 400WheOCECenerLLS Drive. Inc. q q Engineered in German 400 SpecWm Center Drrve,Suite 1400,Irvine,CA 92618,USA]TEL+194974859961EMAIL ingwryQus. cells.coml WEB www.-cells.us v Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Rephase Microinverters rters INPUT DATA(DC) ___ _IQ7-6o-2-US IQ7PLUS-72-2-US Region:AMERICAS _— Commonly used module pairings' Y 235W-350W+ 235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27V-45V Operating range 16 V-48 V 16V-66V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15A 15A Enphase The high-powered smart grid-ready Overvoltage class DC port it u Enphase IQ 7 fvlicro and Enphase IQ 7+Micro' OC port backfeed current 0 A 0 A p PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; dramaticallysimplify the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(Ac) IQ 7 Microinverter IQ 7+Microinverter Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range2 240 V/ - 208V/ 240 V/ 208V/ g P 211-264 V 183-229 V 211-2 64 V 183-229 V IQ Envoy-,Enphase IQ Battery-,and the Enphase Maximum continuous output current 1.0 A(240 V) 1115A(2159'7) 1.21 A(240 V) 1.39 A(208 V) Enlighten-monitoring and analysts software. Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and Overvoltage class AC-port III III undergo over a million hours of power-on testing, AC port backfeed current 6A 0 A enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging Warranty of up to 25 years. EFFICIENCY @240 V @208 V @240 V @208 V _ Peak efficiency 97.6% 97.6% 97.5% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0 MECHANICAL DATA Ambient temperature range _ -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connectortype(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) r------ Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Lightweight and simple Weight 1.08 kg(2.38 lbs) Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans a Built-in rapid shutdown compliant(NEC 2014&2017) Approved for wet locations Yes I Pollution degree P63 Productive and Reliable Enclosure Class II double-insulated,corrasion resistant polymeric enclosure Environmental category/-UV exposure rating NEMA Type 6/outdoor ----- Optimized for high powered 60-cell and 72-cell*modules FEATURES More than a million hours of testing Communication Power Line Communication(PLC) '^ Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break 0 disconnect required by NEC 690" Smart Grid Ready Compliance CA Rule 21(UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Complies with advanced grid support,voltage and CAN/CSA-C22.2 NO.107.1-01 frequency ride-through requirements This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC - Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements '— Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell modules. L 1.No enforced DC/AC ratio.See the compatibility calculator at blips�//enphase.com/en-us/support/module-compatibilit 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area To more about Enphase offerings,visit enphase.com EIV PHA$E. To learn more about Enphase offerings,visit enphase.com n EIV PH-IAS E. J 2019 Enphase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc 2019-3-26