Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50275-Z
� t TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE pryu � SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50275 Date: 1/29/2024 Permission is hereby granted to: Haywood, Zak 2995 Eu enes Rd Cutcho ue,_NY To: construct alterations (finish basement) to existing single-family dwelling as applied for. At premises located at: 2995 Eu enes Rd Cutcho ue SCTM # 473889 Sec/Block/Lot# 97.-3-19 Pursuant to application dated 11/16/2023 and approved by the Building Inspector,: To expire on 7/30/2025. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $517.00 CO-ALTERATION TO DWELLING $100.00 Total: $617.00 Building Inspector "OWE:.:�, TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 htt :'/ww r.sootholdtownn . ora Date Received PERMITAPPLICATION FOR BUILDING For Office Use Only E C E � W E PERMIT NO. y -75 Building Inspector: NOV Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building Department Owner's Authorization form(Page 2)shall be completed. Town of Southold Date:11.07.22 OWNER(S)OF PROPERTY: Name:ZAK HAYWOOD SCTM# 1000- ProjectAddress:2995 EUGENES ROAD, CUTCHOGUE, NY 11935 Phone#:818.636.2320 Email:ZAK.HAYWOOD@GMAIL.COM 6 Mailing Address:2995 EUGENES ROAD, CUTCHOGUE, NY 11935 CONTACT PERSON: Name:STEPHEN SCHEIBLY Mailing Address:255 MAIN STREET, SUITE 200, HUNTINGTON, NY 11743 Phone#:631 .271 .5400 X 102 Email:SSCHEIBLY@DDANY.NET DESIGN PROFESSIONAL INFORMATION: Name:STEPHEN SCHEIBLY, R.A. (DIVERSIFIED DESIGN ASSOCIATES, ARCHITECTS P.C.) Mailing Address:255 MAIN STREET, SUITE 200, HUNTINGTON, NY 11743 Phone#:631 .271.5400 X 102 Email:SSCHEIBLY@DDANY.NET CONTRACTOR INFORMATION: Name:T.B.D. Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure RAddition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ®Yes 0N Will excess fill be removed from premises? DYes ❑No 1 PROPERTY INFORMATION Existing use of property:SINGLE FAMILY RESIDENCE Intended use of property:SINGLE FAMILY RESIDENCE Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_80 this property? ❑Yes �No IF YES, PROVIDE A COPY. ® Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):STEPHEN SCHEIBLY RAuthorized Agent []Owner Signature of Applicant: Date: 12-- STATE ZSTATE OF NEW YORK) SS: COUNTY OF ) STEPHEN SCHEIBLY being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract)above named, (S)he is the AGENT (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this _day of 20 Z� Notary blic DOROTHY KARWOWSKI V407AVZY PUBLIC-STATE Of M11EW YORK AUTHORIZATIONPROPERTY OWNER No. 01 KA6202686 Qualified in Kings County (Where the applicant is not the owner) My commission Expires Morch 23, 20Z5- ZAK HAYWOOD residing at 2995 EUGENES ROAD CUTCHOGUE do hereby authorize STEPHEN SCHEIBLY to apply on my behalf to the Town ofSouth id Building Department for approval as described herein,. �2-1 ng 2,00-2- Owner's Signature Dat ZAP (-(A c,•Cx ►7 Print Owner's Name 2 S.C.T.M.NO. DISTRICT.1000 SECTION:97 BLOCK:3 ' LOT(S):19 R10 27 t--� ,..,r� ���D SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES APPROVAL OF CONSTRUCUTED WORKS FOR OB.L A BE Ll�.F I"'�"LOY I I E S.11 I OC E SEP 14 20 . , _ _OL Ep I BE 20 0 BIMDIN DE". The WEEP depos.,end water suplw hm".at ft[now Ives bees TON"T"C T, UTHOLD insiewAzw =00leel- 01h 110, erap.dTfulfteldt. WJMIF__L�_BEDROOMS h Craig Knepper,I",E.,Chief .� Office of Was e A elcx [L ss 10 tz S zone A9.0 't I I n� icL 9.0 16.4 j.2' i. 10.8 ku. -W"A"mINTW CL 1.1 .A)G LP#4 47,5 P86 LP#5 48.5 'S' CL 103 X08. V2 Jf DRAINAGE CALCULATIONS: A)DWELLING WICOVERED PORCH=1,498 SO.FF 1,498 x 0.166=249cf REQUIRED FINAL SURVEY 07-03-20 (2)8'DIA.3'DEEP DRYWELL=265.f PROVIDED LOC.REAR DECK 02-03-20 a)DRIVEWAY=1,270 SO FT FOUNDATION LOCATION 12-17-19 1,270.0.166=21IFf (1)8'DIA x 5'DEEP DRYWELL=220cf PROVIDED ZONED R-80 NON-CONFORMING LOT FROM YARD:35'MIN THE WATER SUPPLY,WELL-1 DRnEUS AND CESSPOOL REAR YARD:35'MIN LOCA TONS SHOWN ARE FEW FIELD OBSERVATIONS SIDE YARD: IOIMIN.25'TOTAL AND OR DATA OBTAINED FROM OTHERS AREA:13,989.34 SQ-FT, ., 0.32 ACRES FEMA MAP#36103CO164H ELEVATION DATUM. NAVD85 UNAUTHOR12ED ALIENATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT HEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE DRE COMPANY,GOVERNMENTAL AGENCY AND LENDING fNSnTURQN LISTED HEREON,AND TO THE ASSIGNEES OF THE LENDING INS7111TIGH,GUARANTEES ARE NOT TRANSFERABLE. THE f RilON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE -E THE EREC770V VE s EASEMENTS 'Z OR MENS' PROPERTY R H 'T+Y MENT EA EN NOT=.III 'U-E� PROPERTY IV To GUIDE OF FENCES,ADD17IONAL STRUCTURES OR AND OTHER IMPRO - ANDIDR,SUBSURFACE BE V CE S7_RU &R�,-- R�-c,,,O-A--1—RAITEEO UNLESS PHYSICALLY E—T ON THE—AT THE TIME OF SURVEY SURVEY OF.DESCRIBED PV�ERT`lt, CERTIFIED TO: AJD CONSULTANT LLC; -. 'g.1 RESOLUTION TITLE; LED MAP OF: 'F k INSURANCE COMPANY, FI : N Ns - STEWART TITLE s - I SITUATED AT,CUTCHOGUE I�0% Tom OF,SOUTHOLD KENNETH,�_llOYC LANDSURVEY LLC COUNTY, NEW YORK, _I L_M_ and SURVEYING, SUFFOLK P.O. Box 153 Aquebogue,New York 11931 PHONE(631)298-1588 FAX(631) N.Y.S.USC.NO.05 DATE:DEC. 22, 2018 _'—_ '__D--. .WvVBVW S.C.T.M.NO. DISTRICT:IDOO SECTION:97 BLOCK:3 LOT(S):19 #R70-19-0027 0.6.8 REBNR i �7ttp:5 1 �y HEOM' I To00 i'y CL 7.8 k 0.py0k' /%is� 0,6. `t qL 7.8 0 it C-2 ! / 171 Z 20nE aE(EL 6) :q -- 1-3 t.L/l 1 ' nm J` i 8 50Av e / 11' 6 E 88.0 ILt19.0 0 EL 7L.—�� i I My aAs 30x�x 9 c. fob K4 58 MiR EL 10.018 fCL 70.6 J p 11 " ^CL 11.1 �� wv � III 1 � �i 8 �2 114 EL 10.5 8 y`s�i 00 3 ( I tl 7l �y JRa 0Y�L,% t S e'7` 541JR PoNTA'IO POINT"8" i '� •' 8�.-LEP c OCA S.T. 27' 30' II ok5 z4♦v 9 F WEtt� M. 'E pP WP �J 5 CL 10.7 LPJ2 40' 24. LP#3 44' 17' EL 9.7 LPI4 47.5' 24.5' RFb�R \V TJ LP#5 48.5' 15' 797-20 a ta.z icy oP'p DRAINAGE CALCULATIONS: A)DWELLING W/COVERED PORCH=1,498 SO.FL UPDATE/ADD TOP01 08-01-22 1,498 x 0.166=249cf REQUIRED FINAL SURVEY 07-03-20 (2)EVA x 3'DEEP DRYWELL=265cf PROVIDED LOC. REAR DECK 02-03-20 B)DRIVEWAY=1,270 SQ.FT. FOUNDATION LOCATION 12-17-19 1,270 x 0.166=211cf (1)8'DIA x 5'DEEP DRYWELL=2200 PROVIDED ZONED R-80 NON-CONFORMING LOT FRONT YARD:35'MIN THE WATER SUPPLY, WELLS,DRYWELLS AND CESSPOOL REAR YARD: 35'MIN LOCATIONS SHOWN ARE FROM FIELD OBSERVA770AIS SIDE YARD: 10'MIN, 25'TOTAL AND OR DATA OBTAINED FROM OTHERS, AREA: 13,989.34 SQ.FT. or 0.32 ACRES FEMA MAP#36103CO164H ELEVATION DATUM: NAVD88 UNAUTHORIZED ALTERATION OR AGIN RON TO THIS SURVEY IS A WOLA77ON OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURREY MAP NOT BEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TIRE COMPANY,GOVERNMENTAL AGENCY AND LENDING INST77UTION LISTED HEREON,AND TO THE ASSIGNEES OF THE LENDING INSTITUTION,GUARANTEES ARE NOT TRANSFERABLE THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO 711E STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES,ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS. EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF:DESCRIBED PROPERTY CERTIFIED TO: AJD CONSULTANT LLC; MAP OF: f�w A RESOLUTION TITLE; .I FrSTEWART TITLE INSURANCE COMPANY; FILED: g*h 8 _ p3 SITUATED AT:CUTCHOGUE TOWN ?c wN OF.SOUTHOLD t KENNETH M WOYCHUK LAND SURVEYING, PLLC 'n SUFFOLK COUNTY, NEW YORK , lsoaa2/e='V Professional Land Surveying and Design =a P.O. Box 153 Aquebogue, New York 11931 18-1'550 SCALE:1"=30' DATE:DEC. 22, 2018 PRONE(831)298-1888 FAX(831)298-1588 FILE N.Y.S.LISC.NO. 050882 m>mtatw,>g we--oe Rohert J,eenneeey&xen—tn R.soyomn 6ENERA,L= NOTE5 SSS 7 "V TSS's � THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY 11 1 A jr THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL OD REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE V IZE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER THE ARCHITECT SHALL A5515T THE OWNER IN FILING AND OBTAINING ALL LOCAL BUILDING DEPARTMENT APPROVALS FOR THE CONSTRUCTION DOCUMENTS OF THI5HAY E C SIIL N E �� �i5 LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE PROJECT. ALL FEES RELATED TO THIS APPROVAL PROCESS SHALL BE PAID FOR BY ` ARCHITECT SHALL H DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. THE OWNER. UPON BUILDING DEPARTMENT APPROVAL, AND PROCURING A BUILDING PERMIT,, THE GENERAL C:CNTRACTOR 15 NOW RESPONSIBLE FOR THE TAKING OUT IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION AND PAYMENT FCNZ ANY ADDITIONAL PERMITS AND/OR RELATED FEES REQUIRES TO OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I SUC.GE SSFULLY COMPLETE THE PROJECT UNTIL T1 'GEZTIFIGATI= OF OCCUPANCY" IS ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY" SECURED. FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE 2 CONTRACTOR SHALL PERFORM ALL WORK IN COMPLIANCE W2995 EUG N S 0 AD SPECIFIC DESCRIPTION OF THE ALTERATION. IAS PER THE NEW YORK STATE EDUCATION WITH ALL APPLICABLE CODES, CODE LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) AMENDMENTS, STANDARDS, RULES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO THE FO110YVIN5: -rh , JL , LOCAL ZONING ORDINANCESCUTC7ff X NOTES: THE: NEW YORK STATE RESIDENTIAL CODE - 2020 EDITION -NJY 11935 -, 7ff-OG'ur LOCAL BUILDING DEFARTMENT REOUIREMENT5 WOOD FRAME CONSTRUCTION MANUAL FOR ONE AND TWO FAMILY DWELLINGS (2018 EDITION) 3 THE CONTRACTOR IS RESPONSIBLE FOR "METHODS AND MEANS OF C:ON5TRUCTION". \ ZONE AE(EL (b) ZONE X 4 CONTRACTOR SHALL PROM AND B PO 5 OR, G SHORING AND BRACING AS REQUIRF� FOR THE SAFE INSTALLATION OF HIS WORK. FLOOD ZONE BOUNDARY EL 6.8\ EL 7.5 5 SHOULD UNFORESEEN CONDITIONS OR OTHER CAUSES NEGE551TATE CONSTRUCTION ` DETAILS NOT IN ACCORDANCE WITH THESE PLANS, CONTRACTOR SHALL NOTIFY THE \ / / G7L 8 PROPER AUTHORITIES AND SUBMIT HI5 DETAILS SHOWING THE PROPOSED METHOD TO MIN. REAR YARD ti�0� \O ACCOMPLISH THE REQUIREA D RESULT. / 6 WHEN OWIsIER/CONTRACTOR 515N CONTRACT, THE AIA GENERAL CONDITIONS �`���`' S'S !/,v, ❑\r 1L 7.8 rn 11 FORM A201 SHALL GOVERN. (. 7 NO NOTE: OR LACK THEREOF SHALL BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM 114E EXECUTION OF ALL WORK IN AC 0RDANGE WITH ALL STATE AND/OR LOCAL CODES. ° � 3 8 THE CONTRACTOR 15 NOT TO 5GAI E DRAWINS(5) AND 15 TO USE DIMEN51ONAL �/ - --_J ��� �/� 17.8 NOTATIONS ONLY. EL 5.5 DI 7.64 / -� -� �'� q THE SENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VISIT THE SITE AND / I VERIFY ALL DIMEN51ONS AND JOB CONDITIONS PRIG TO CONSTRUCTION AND SHALL REPORT TO THE ARCHITECT FOR RE50LUTION PRIOR TO COMMENCEMENT OF WORK ANY DISCREPANCIES OR OMISSIONS WHIGH WOULD INTERFERE WITH THE r SATISFACTORY COMPLETION OF THE WORK. 10 THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY ERRORS OR PROPOSED E6RE551 /�/ -'� �/ 8.3 AME316UITIE 5 IN AND BETWEEN THE PLANS, DRAWINGW 5 AND SPECIFICATIONS PRIOR TO AREAWAY PROCEEDING WITH THAT PORTION OF THE WORK. IF SUCH NOTICE 15 NOT FURNISHED TO ' 1 THE ARCHITECT, THE CONTRACTOR SHALL BE DEEMED TO HAVE INSPECTED THE EXIST. DRY WELL PLANS, DRAWINGS, 5PECIFIGATION5 AND HAS FOUND THEM IN PROPER FORM FOR TO REMAIN I EXECUTION. ON. II CONTRACTOR TO PROVIDE ALL NECE55ARY BARRICADES, GUARD5, WARNING I . ' 1 L q.0 LIGHT5, 516N5, ETC., TO INSURE THE SAFETY OF THE WORK AREA. \J EL -1. - -- I 12 CONTRACTOR SHALL PROVIDE ALL MATERIALS, PERFORM ALL WORK AND INSTALL ZONE AE(EL ,�O4I ALL MATERIALS IN ACCORDANCE WITH RECOGNIZED GOOD STANDARD PRACTICE. ZONE X NGF 1 AAGE CONTRACTOR 15 RE5PON51BLE FOR INFORMATION THAT PERTAINS SOLELY TO THE FABRICATIONS PROGE55 OR THE TEGHNIGUE5 OF CONSTRUCTION AND FOR `� ,� p 'r>=1_ 13,8 --EL ti:q COORDINATION OF THE WORK OF ALL TRADES. 10 FLOOD ZONE 1 1 I I GL 10.6 LINE OF EXIST. DECK TO � � '_ BOUNDARY REMAIN 13 ALL DISTURBED AREAS TO BE REPAIRED IN KIND BY GENERAL CONTRACTOR. 14 MINOR ITEMS SUCH AS PATCHING, BLOGKING,TRIM, ETC. SHALL BE PERFORMED ; �; p ________ S GL 11.1 al / ' �- AS REC�UIRED TO MAKE THE WORK COMPLETE WHETHER SHOWN OR NOTED ON � � HATCH INDICATES AREA OF EXIST. THE DOCUMENTS OR NOT. 1 i �� 1 / O BASEMENT TO BE FIN15HED (548 5.F.,) 2. 01.15.24 ISSUED FOR BUILDING DEPARTMENT FINISHED BASEMENT FILING 15 CONTRACTOR SHALL MAINTAIN THE 51TE IN A SAFE,GLEAN AND ORDERLY FASHION EL IOS 1. 11.23.22 ISSUED FOR PRELIM.BUILDING DEPT.REVIEW FOR THE DURATION OF THE CONSTRUCTION PERIOD. ALL MATERIAL (GONGRETE, \ II 110 /� y , �` 3 % ` r N0. DATE: DESCRIPTION: FILL, mOD, ETC) AND CON5TRUGTION DEBRIS TO BE REMOVED AT THE END OF ® J 1 111 X ��,p � �e� 1 GL II. EACH PiORK DAY AND SHALL BE DISPOSED OF REGULARLY AT A LEGAL OFF SITE i 11 W\DCa �� / �� PORCH lb ISSUANCE: WASTE FACILITY. I 1 -- Ib THE CONTRACTOR SHALL BE RE5PON51BLE FOR ANY DAMAGE INCURRED AWNHERE 0< `la D i V E R S i F i E D D E S i G N WITHIN THE BOUNDARIES OF THE PROPERTY AND ANY DAMAGE SHALL BEl E�(15T PROMPTLY REPAIRED TO THE 5AT15FACTION OF THE ARCHITECT AND OWNER. 1 1 A T E S 1�LL °1SC ® A R C H I T E C T S P C 17 NOTATIONS ON ANY PLAN, ELEVATION, SECTION OR DETAIL ARE APPLICABLE TO MIN. SIDE YARD �'® �/ t: 6 GL 10.7 ALL PLANS, ELEVATIONS,SECTIONS AND DETAILS. --mi, \p \_ / .01 18 PROVIDE 1/2" W.R. GYPSUM WALL BOARD ALL WALL5/CEILING5 OF "WET" AREAS - (SHOWERS, TUBS, ETC) EL q.7 NOTE: THI5 PROPERTY HAS NOT BEEN �� OF DEEDED AC CESS TO PRIVATE I q ALL NEW APPLI ANDES ARE AS 5ELEGT ED BY OWNER AND SHALL BE INSTALLED 0.4r % CG90 AGGE55 ROAD (BANKS STREET). 255 MAIN STREET SUITE 200 H U N T I N G T 0 N. NY 1 1 7 4 3 BY THE CONTRACTOR A5 PER THE MANUFACTURERS SPECIFICATIONS. / � �. THI5 LOT 15 NOT A CORNER LOT. P.631.271.5400 WWW.DDANY.NET F.631.271.4844 20 ALL INTERIOR WOOD TRIM/BA5E SHALL BE AS SELECTED BY OWNER GL 10.2 Copyright ©2022 AND IN13TALLED BY THE GENERAL CONTRACTOR. Diversified Design Associates-Architects,P.C. 21 TYPE/LOGATION/EXTENT OF ALL NFJN INTERIOR FINISHES (PAINT, CERAMIC TILE, K7ARCH I 7EC7URAL 5 I 7r= FLAN 51TE PLAN INFORMATION ADAPTED FROM SURVEY PREPARED BY All Rights Reserved. VINYL "FILE, CARPET, ETG) SHALL BE AS SELEGTED/DIREGTFD BY OWNER. CLIMATIC S ®�RAPHIC DE5I6I � CRITERIA SCALE : I 20O KENNETH M. WOYGHUGK, LAND SURVEYOR, AQUEBOGUE , NY AND DATED 08.012022 SEAL: PROJECT NORTH: 22 ALL El EGTRIGAL, PLUMBING AND H.V.A.G. TO BE IN STRICT ACCORDANCE WITH THE � CS " = ' - " INTERNATIONAL RESIDENTIAL CODE AND ALL APPLIGA13LE LOCAL REGULATIONS. SUBJECT TO ICE BARRIH2 FLOOD GROUND WIND DESIGN 5E15M(, AIR MEAN ZONING I N OR1�f AT l ON - 23 INSTALL SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS IN ACCORDANCE SNOW OB16N DAMAGE BY WINTER MPJAAY- HAZARDS FREEZIN ANNUAL rOR� s1>6u,At DE-516N MENT LOAD SPED Bme GA WA71Bt FROST TERMITE ZONE AE-b/ INDEX TEMP. WITH ALL STATE AND LOCAL CODE REGRAREMENT5. �flr, wryDEBRIS PROPERTY ADDRE55: 2gg5 EU6ENE5 ROAD TAX MAP NO. SECT. q1 BLOCK 3 LOT iq A•PW E�cTS REaoN WW It4� >EH REC�l11RED ZONE X C;UTGHOSl1E, NY IIg35 PROPERTY ZONING: ZONE R-60 NONCONFORMING LOT 24 PRIVA17E GARAGE SHALL BE SEPARATED HORIZONTALLY AND VERTICALLY FROM EFFECTIVE THE RE51DENGE WITH NOT LE55 THAN %m TYPE X 6YP5UM BOARD MoD. FIRM` 1500 ITEM PERM I TTED/ REQUIRED PROVIDED COMPLIANCE 30 PSF 128 NO NO NO "B" 3'-0" Og/25/2C TO 15 YES OR HEA PANEL #: LE:55 50.8 MINIMUM LOT AREA 8013,g8q.34 S.F. EXISTING NON-GONFCMING ,000 S.F. * 25 OPENINGS FROM A PRIVATE GARAGE INTO A RESIDENCE SHALL BE EQUIPPED WITH 36103C,0164H MAXIMUM LOT C.OVERASE 20% (2,7g7.q 5.FJ 1226 % (1,714.g8 5.F) COMPLIES A 20 h11NUT1= FIRE RATED DOOR ASSEMBLY WITH ASELF-GLC5ING DEVICE. I LE: THIS PROJECT IS IN COMPLIANCE WITH: MINIMUM FRONT YARD SETBACK 35 FEET 35 FEET COMPLIES PROJECT T 26 CONTRACTOR TO SCHEDULE AND OBTAIN ALL NECESSARY UTILITY STAKE OUTS Le. THE RESIDENTIAL CODE OF NEN YORK STATE - 2020 EDITIONADDITION & NESP DECK: WATER,, ELEGTRIG, SEPTIC d 6A5 PRIOR TO COMMENGINS WITH ANY 51TE WORK. MINIMUM REAR YARD SETBACK 35 FEET 5g.8 FEET COMPLIES AFPA WOOD FRAME C;ONSTRUGTION MANUAL FOR ONE AND TWO FAMILY DWELLINGS - 2018 EDITION THE ENERGY CONSERVATION CODE OF NEW YORK STATE- 2020 EDITION MINIMUM 51DE YARD SETBACK 10 FEET 13.4 FEET COMPLIES HAYW 0 0 D RESIDENCE THE ZONING CODE OF THE TOWN OF SOUTHOLD MINIMUM 51DE YARD AGGREGATE 25 FEET 33.6 FEET COMPLIES 2995 EUGENES ROAD NFPA 70 STANDARD - 2017 EDITION NATIONAL ELECTRICAL CODE 2017 MAXIMUM BUILDING HEIGHT 2 1/2 STORIES OR 35 FEET 282 FEET ICOMPLIES CUTCHOGUE , NEW YORK 11935 0 NOTE: NONCONFORMING LOT;FOLLOW REQUIREMENTS OF 5**Too��50L L L157 ®F E;�RAKN675 § 280-124 -CNF LOTS LE 55 00 20p00 S.F. AND §280-15 FOR LOTS IOp00 5F TO Iq,ggg SF DRAWING TITLE: 65-I SITE PLAN, GENERAL NOTESSYMBOL DESGRHPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION A-100 GENERAL NOTES, REQUIRED 515N P05TING, INTERIOR ELEVATION, PLUMBING RI5ER DIAGRAM LOT GOYERAGE ANALYSIS GENERAL NOTES A-101 EXI5TIN5 FIRST FLOOR EXISTING LOT AREA: 13,g8q.34 S.F. LIST OF DRAT NI NGS x DOOR REFERENCE A-102 FOUNDATION PLAN, NOTES AND DETAILS MAX. PERMITTED LOT COVERAGE =20 % OF LOT AREA ARCHITECTURAL 51TE PLAN SECTION REFERENCE X ELEVATION TAG SEE O SCHEDULE g8q.34 5F x 20% = 23CI-TA 5F MAX. PERMITTED LOT COVERAGE RE50HECK COMPLIANCE OERT. y SEE DWDWG. AS NOTEDG. AS NOTED REAR ELEVATION -00LIGHTING AND ELEGTRIGAL PLAN ITEM AREA EXISTING PRINCIPAL DWELLING 6RO55 FLOOR AREA 15T FLOG 1,477.54 5F NOTE REFERENCE- SEE WINDOW REFERENCE DRAWN BY: SDE SHEET N0. DETAIL REFERENCE- NOTE DONT PORCH AND STEPS 41.65 SF x SEE DWG. AS NOTED XXX NOTE LEGEND FOR X - SEE WINDOW X-X ADD'TL INFO. SCHEDULE EXI5TIN5 DECK Ig5.7q 5F NALL TYPE EXISTING TOTAL= 1714.g8 5F CHECKED BY: 5J5 ELEVATION xx REFERENCE - SEE REVISION BENCHMARK WALL TYPES TAG DATE: 01.15.24 ROOM ❑ FURNITURE / EQl11PMENT SCALE: A5 NOTED CSm 1 NUMBER X REFERENCE - SEE _ 101 TAG SCHEDULE EXISTING LOT COVERAGE % - 1226 PROJECT N0. 221q 51TE WORK FRAMING - CONSTRUCTION LUMBER AIR BARRIER AND INSULATION INSTALLATION I. STAKEOUT 15 TO BE PERFORMED BY A LICENSED SURVEYOR. STAKING AND LAYOUT I FRAMING LUMBER SHALL BE 5QUARE-EDGE, 5TRAIGHT, SOUND, WELL-5EA50NED, WITH A [REFERTO TABLE R402.4.1.1 OF THE RESIDENTIAL GORE OF NEW YORK STATE] THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL L ARE TO ESTABLISH ALL LINES AND BENCHMARKS AND VERIFY ALL GIVEN DATA ON MAXIMUM MOISTURE CONTENT OF NINETEEN (lq%) PERCENT AT THE TIME OF IN LATION IN517LL TIO REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE DRAWINc55. IN CASE OF DI56REPANGY, RECEIVE CLARIFICATION FROM ARCHITECT INSTALLATION. LUMBER SHALL BEAR THE GRADE AND TRADEMARKS OF THE COMPONENT AIR, BARRIER CRITERIA CRITERIA INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER PRIOR TO PROGEEDING. ASSOCIATION BY NH05E RULES IT IS PRODUCED, SIZES INDICATED ARE NOMINAL LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE GENERAL REQUIREMENTS A CONTINUOUS AIR BARRIER SHALL BE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL STANDARD SIZES. INSTALLED IN THE BUILDING ENVELOPE AIR-PERMEABLE INSULATION SHALL NOT BE COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. 2. EXGAV�:TE AND BACK FILL FOR WORK INDICATED ON DRAWINGS. STOCKPILE 2 FRAMING LUMBER SHALL BE STRESS-RATED DOUGLAS FIR LARCH NO. 2 WITH A THE EXTERIOR THERMAL. ENVELOPE CONTAINS L15ED AS A SEALING MATERIAL TOPSOIL. OBTAINED FROM STRIPPING BUILDING 51TE AND STOCKPILE ALL EXCAVATED 5TRE55 RATING OF 815 PSI RESPECTIVELY FOR BENDING FOR SINGLE MEMBER USE A CONTINUOUS AIR BARRIER IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION MATERIAL. AT THE SITE. AND g0 PSI MINIMUM FOR SHEAR. B��JOINTS, I THE AIR BARRIER SHALL OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I BE ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 3. NEW AND EXISTING BACK FILL MATERIAL AND TOP501L ARE TO BE FREE OF WEEDS, 3 PROVIDE DOUBLE FRAMING AROUND ALL OPENINGS, UNDER ALL PARALLEL WALLS AND THE AIR BARRIER IN ANY DROPPED CEILING/ ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY" TREE ROOTS, ROCKS AND DEBRIS. UNDER BATHTUBS. PROVIDE SIMPSON HANGER CONNECTIONS AT ALL FLUSH CEILING/ATTIC SOFFIT SHALL BE ALIGNED w/THE INSULATION FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE THE INSULATION IN ANY DROPPED CEILING/ SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION STRUCTURAL LOAD BEARING CONDITIONS. AND ANY 6AP5 IN THE AIR BARRIER SHALL SOFFIT SHALL BE ALIGNED w/THE AIR LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) 4. ALL U5 MATERIAL THAT 15 UNSUITABIJ= FOR BACK FILL MATERIAL SHALL BE 4 PROVIDE 50LID BRIDGING BETWEEN JOISTS AT 6'-0" o.c. MAXIMUM. ACG OBE PENINGS,DROP DOWN STAIRS OR BARRIER REMOVVEDEE FROM THE SITE. KNEE WALL DOORS TO UNCONDITIONED ATTIC NOTES: 5 UNLESS OTHERWISE NOTED, ALL WINDOW AND DOOR OPENINGS SHALL HAVE (2) 2" X 10" SPACES SHALL BE SEALED. 5. PROTECT ALL TREES WITHIN EIGHT FEET OF THE BUILDING. HEADERS ABOVE. CAVITIES w/CORNERS AND HEADERS OF WALLS THE JUNCTION OF HE FOUNDATION AND SILL FRAME WALLS SHALL BE INSULATED 6. PROPER. APPROVAL MUST BE OBTAINED BEFORE GOVERING (BACK FILLING) ANY 6 ALL PLATES IN CONTACT WITH FOUNDATION WALLS TO BE PRE55URE TREATED AND PLATE �BE `�' COMPLETELY FILLING THE CAVITY WITH A THE JUNCTION OF THE TOP PLATE AND THE EXCAVATED WORK HAVE CONTINUOUS METAL TERMITE SHIELDS. PLATES SHALL BE BOLTED TO TOP OF EXTERIOR WALLS SHALL BE SEALED MATERIAL HAVING A THERMAL RESISTANCE FOUNDATION WALLS WITH 5/8" DIAMETER BOLTS AT 48" o.c. MAXIMUM AND 1'-0" KNEE WALL5 SHALL BE SEALED. OF R-5 PER INCH MINIMUM. -]• CONTRACTOR 15 RE5PON51131E TO CONTACT ALL UTILITY COMPANIES AND REQUEST MAXIMUM FROM EACH CORNER. BOLTS MUST BE EMBEDDED A MINIMUM OF 1" INTO EXTERIOR THERMAL ENVELOPE INSULATION FOUNDATION WALLSFORGE MORTAR INTO THE JOINT BETWEEN 51H BOTTOM AND FOR FRAMED WALLS SHALL C INSTALLED IN . UTILITY STAKEOUTS PRIOR TO COMMENCING WITH EXCAVATION. SUBSTANTIAL CONTACT AND CONTINUOUS CONCRETE AND FOUNDATION TOP OF FOUNDATION. ALIGNMENT WITH THE AIR BARRIER 1 ALL 5UB-FLOORIN6, WALL AND ROOF SHEATHING SHALL BE EXTERIOR GRADE COX WINDOWS,SKYLIGHTS THE SPACE BETWEEN WINDOW/DOOR JAMBS 1. ALL CONGRETE OR MA50HRY WORK SHALL BE DONE DURING TEMPERATURES OF 32 PLYWOOD, 5UB-FLOORING - 3/4", WALL SHEATHING - 1/2", ROOFING SHEATHING - 5/8". AND DOORS AND FRAMING AND SKYL16HT5 AND FRAMING DEGREE5 FAHRENHEIT AND RISING MINIMUM. SHALL BE SEALED 8 ALL BUILT-UP WOOD GIRDERS AND HEADERS SHALL NOT HAVE ANY SPLIT ON THE RIM JOISTS RIM JOISTS SHALL INCLUDE THE AIR BARRIER RIM JOISTS SHALL BE INSULATED 2. NO CONCRETE SHALL BE PLACED ON FROZEN 5URFAGE5. WIDE FACE OF ANY MEMBER GREATER THAN 1/2 TIMES THE WIDE FACE. g ALL EXPOSED WOOD FOR SOFFITS, OVE:RIHANGS, ETC. SHALL BE APPROVED FLOORS(INCLUDING THE AIR BARRIER SHALL BE INSTALLED AT FLOOR FRAMING CAVITY INSULATION SHALL 3. NO ADDITIVES SHALL BE ALLOWED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT. EXTERIOR GRADE. ABOVE GARAGE 4 ANY EXPOSED EDGE OF INSULATION BE INSTALLED TO MAINTAIN PERMANENT CANTILEVERED FLOORS) CONTACT WITH THE UNDERSIDE OF SUBFLOOR 4• ALL CONCRETE WORK SHALL CONFORM TO REQUIREMENTS AND RECOMMENDATIONS 10 ALL FLJ5H FRAMING CONNECTIONS SHALL BE MADE WITH J015T HANGER5, FRAMING DEGKIN6,OR FLOOR FRAMING CAVITY OF AGI-301-ga "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" ANCHORS, OR RAFTER ANCHORS OF MINIMUM 18 GAUGE PRIME GALVANIZED STEEL AS INSULATION SHALL BE PERMITTED TO BE IN CONTACT WITH THE TOP SIDE of SHEATHING, ft'=3000 P51). ALL EXPOSED 5LAB5, GARAGE SLABS AND STEPS SHALL BE 3500 MANUFAGTURED BY "51MP50N" 5TRONG TIE CONNEGTOR5. SIZED AND NAILED AS PER OR CONTINUOUS INSULATION P51 AIR--ENTRAINED. REINFORCING STEEL SHALL CONFORM TO A5TM A-615 GRADE 60 REACTIVE LOAD. INSTALLED ON THE UNDERSIDE OF FLOOR FRAMING AND EXTENDS FROM THE BOTTOM 5. PROVIDE ALL SLEEVES AND FOUNDATION VENTS AS REQUIRED BY RESIDENTIAL 11 NAILING TO CONFORM TO SCHEDULE INDICATED IN THE WOOD FRAME CONSTRUCTION TO THE TOP OF ALL PERIMETER FLOOR CODE OF N.Y.S. MANUAL FOR ONE AND TWO FAMILY DWELLINGS UNLESS OTHERWI5E NOTED. FRAMING MEMBERS CRAWL SPACE WALLS EXPOSED EARTH IN UNVENTED CRAWL SPACES WHERE PROVIDED INSTEAD OF FLOOR 6. UNLESS OTHERWI5E INDICATED, ALL FOUNDATION FOOTING ARE TO BE MINIMUM 12" 12 LEAVE I/I6a SPACE AT ALL PLYWOOD PANEL END JOINTS AND I/8„ SPACE AT ALL ALL BE COVERED WITH A GLASS I VAPOR INSULATION, INSULATION SHALL BE PANEL EDGE JOINTS. RETARDER WITH OVERLAPPING JOINTS TAPED PERMANENTLY ATTACHED TO THE DEEP X 24" WIDE, CENTERED UNDER THE FOUNDATION WALL (OR AS PER DETAILS) CRAHLSPACE WALLS 13 PROVIDE SOLID BLOGKING FROM TOP/GIRDER OR FOUNDATION WALL TO THE SHAFTS,PENETRATIONS DUCT SHAFTS,urIL1TY PENETRATIONS,AND 1, PROVIDE TWO #5 DEFORMED BARS CONTINUOUS IN THE FOOTING AND A CONTINUOUS UNDERSIDE OF FLOOR AT WOOD POSTS. ALL WOOD POSTS SHALL BE 4"X4" MINIMUM. FLUE SHAFTS OPENING TO EXTERIOR OR 2"x4" KEY BETWEEN THE FOOTING AND FOUNDATION WALL EXCEPT A5 NOTED UNCONDITIONED SPACES SHALL BE SEALED OTHERWISE. 14 NOTATIONS ON ANY PLAN, ELEVATION, SECTION OR DETAIL ARE APPLICABLE TO ALL BATTS IN NARROW CAVITIES SHALL BE CUT TO PLANS, ELEVATIONS, 5EGTION5 AND DETAILS. NARROW CAVITIES FIT,OR NARROW CAVITIES SHALL BE FILLED BY 8. PROVIDE 5/8" X 12" ANCHOR BOLTS. ALL FOUNDATION WALL5 SHALL HAVE ANCHOR 15 JOISTS ARE NOT TO BE NOTCHED. ALL HOLES FOR PLUMBING MUST BE DONE IN INSULATION THAT ON INSTALLATION READILY BOLT5 5ET APPROXIMATELY ONE FOOT FROM EACH CORNER AND SPACED 48" ON CONFORMS TO THE AVAILABLE CAVITY SPACE CENTER„ THERE SHALL BE ANCHOR BOLTS ON EITHER 51DE OF ANY OPENING AND AT ACCORDANCE WITH WESTERN WOODS GUIDELINES FOR DIMEN51ONAL LUMBER. 6ARA6E SEPARATION AIR SEALING SHALL BE PROVIDED BETWEEN LEAST ITO BOLTS IN ANY ONE 51H . THE 6ARAGE AND CONDITIONED SPACES 16 INSTALL FIRESTOPPING AT ALL REQUIRED LOCATIONS COMPLY WITH GOVERNING RECESSED LaGHT FLXTURES INSTALLED IN THE g. PROVIDE PR.EMOLDED JOINT FILLER BETWEEN SLABBUILDING THERMAL ENVELOPE SHALL BE S AND FOUNDATION WALLS. CODES. RECESSED LIGHTING RECESSED LIGHT FIXTURES INSTALLED E THE BUILDING THERMAL ENVELOPE SHALL BE AIR TIGHT AND IG RAT7=D. 11 ALL HORIZONTAL FRAMING BEARING ON BEAMS, GIRDERS OR PARTITION TOP PLATES TO THE DRYWALL 10. ALL FOOTINGS SHALL BEAR ON UNDISTURBED 501E WITH MINIMUM BEARING CAPACITY SHALL BE LAPPED 4' MINIMUM. BATT INSULATION SHALL BE GUT NEATLY TO OF I T0145/5F BEARING CAPACITY. CONTRACTOR SHALL HAVE THE LEVEL OF PLUMBING AND WIRING FIT AROUND WIRING AND PLUMBING IN ACCEPTABLE BEARING STRATA VERIFIED IN FIELD. 18 ALL HEADERS TO BE SUPPORTED BY MINIMUM (2) 2"x4" OR 4"x4" POSTS UNLE55 EXTERIOR WALLS,OR INSULATION THAT ON OTHERWI5E NOTED. INSTALLATION READILY CONFORMS TO 11. ALL POURED CONCRETE SLAB5 ARE TO BE 4" THICK WITH 6X6, 10/10 W.W.M. OVER 6 AVAILABLE SPACE SHALL EXTEND BEHIND MIL. POLYETHENE VAPOR BARRIER OVER 6" COMPACTED GRAVEL. UNLE55 INSULATION / VENTILATION NOTES PIPING AND WIRING OTHERWISE NOTED. SHOAER/TUB ON THE AIR BARRIER INSTALLED AT EXTERIORRECESS LIGHT FIXTURES INSTALLED IN THE EXTERIOR WALL WALLS ADJACENT TO SHOWERS AND TUBS BUILDING THERMAL ENVELOPE SHALL BE AIR I THI5 PROJECT HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEW YORK ALL SEPARATE THEM FROM THE SHOWERS TIGHT AND IG RATED. 12• ALL CONCRETE SHALL VIBRATED IN AGGORDANGE WITH STANDARDS SET FORTH STATE ENERGY CODE. THERE SHALL BE NO DEVIATION FROM THE R VALUES INDICATED AND TUB5 BY THE AGI AND GENERAA LLY ACCEPTED BUILDING PRACTICE. ON THE DRAWINGS. ELECTRICAL/PHONE BOX THE AIR BARRIER SHALL BE INSTALLED BEHIND 13. ALL CONCRETE BLOCK SHALL CONFORM TO A5TM CqO;MORTAR SHALL BE TYPE "M" 2 ALL PENETRATIONS THROUGH FLOORS AND RIM BOARDS FOR ELECTRICAL AND ON EXTERIOR WALLS ELECTRICAL OR COMMUNICATIONS BOXES OR MECHANICAL/PLUMBING ACCESS ARE TO BE FILLED COMPLETELY WITH EXPANDING AIR SEALED BOXES SHALL BE INSTALLED FOAM SEALANT. 2. 01.15.24 ISSUED FOR BUILDING DEPARTMENT HVAC REGISTER BOOTS HVAC RE615TER BOOTS THAT PENETRATE FINISHED BASEMENT FILING 3ALL CAVITIES AT WINDOW AND DOOR OPENIN65 SHALLBE FILLED WITH MINIMAL BUILDING THERMAL ENVELOPE SHALL BE FOUNDATION WATERPROOFING EXPANDING FOAM SEALANT SPECIFICALLY DESIGNED FOR WINDOW AND DOOR USE. SEALED TO THE SUBFLOOR OR DRYWALL 1. 11.23.22 ISSUED FOR PRELIM.BUILDING DEPT.REVIEW 1• FOUNDATION WALL EXTERIIOR SURFACES TO BE PROTECTED FROM BOTTOM OF CONGEALED SPRINKLERS WHEN REQUIRED TO BE SEALED,CONGEALED FI NO. DATE: DESCRIPTION: 4 INSTALL INSULATION BAFFLES AT ALL VAULTED GEILING5 AND AT SOFFIT EN05 NEAR SWINKLER5 SHALL ONLY BE SEALED IN A FOOTING TO WITHIN I" OF FINISHED GRADE WITH THE SPRAYED APPLICATION OF TOP PLATES TO PROVIDE UNINTERRUPTED AIR FLOW TO RIDGE VENT. MANNER THAT 15 RECOMMENDED BY THE 'TUFF N DRI'. PROVIDE BACK FILL PROTECTION BOARD. MANUFACTURER. CAULKING OR OTHER ADHESIVE ISSUANCE: 5 RIDGE VENT5 AS INDICATED ARE TO BE 5HIN6LE-VENT If AS MANUFACTURED BY SEALANTS SHALL NOT BE USED TO FILL V0I05 "AIR-VENT" BETWEEN FIRE SPRINKLER COVER PLATES AND wALL5 OR CEILINGS D ! V E R S ! F ! E D D E S ! G N ROOFING NOTE5 A T E S STRUCTURAL STEEL TO EXIST A R C H I T E C T S P C . I. ALL STEEL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE A15G I AS PER SECTION R905.12 OF THE IRG. AN ICE BARRIER SHALL BE INSTALLED FOR 5EPTIG SYSTEM C "5PEGIFIGATION5 FOR DE516N, FABRICATION AND ERECTION OF STRUCTURAL STEEL ASPHALT SHINGLES, METAL ROOF 5HIN65LJ=5, MINERAL-SURFAGED ROLL ROOFING, FOR BUI1LDIN65". STEEL HALL CONFORM TO ASTM A-512 (GRADE 50) AND A-501 SLATE AND 5LATE-TYPE 5HIN6L E5, WOOD 5HIN6LE:5 AND WOOD SHAKES. THE ICE BARRIER SHALL CONSIST OF NOT FEWER THAN TWO LAYERS OF UNDERLAYMENT CEMENTED TOGETHER, OR A SELF ADHERING POLYMER-MODIFIED BITUMEN SHEET DEMOLITION SHALL BE USE IN PLACE OF NORMAL UNDERLAYMENT AND EXTEND FROM THE LOWEST E06E5 OF ALL ROOF SURFACES TO A POINT NOT LE55 THAN 24 INCHES I N51 DE THE 2„ a 255 MAIN STREET SUITE 200 H U N T I N G T O N, NY 1 1 7 4 3 1 REFER 'TO GONSTRUGTION DOCUMENTS FOR SPECIFIC DEMOLITION LOGATION/NOTES. EXTERIOR WALL OF THE BUILDING. ON ROOFS WITH SLOPE EQUAL TO OR GREATER 2 P.631.271.5400 WWW.DDANY.NETF.631.271.4844 THAN 8 UNITS VERTICAL IN 12 UNITS HORIZONTAL, THE ICE BARRIER SHALL ALSO BE ■ 2 WHERE EXISTING WALLS ARE SHOWN TO BE REMOVED AND/OR NEW OPENINGS ARE APPLIED NOT LE55 THAN 36 INCHES MEA5URED ALONG THE ROOF SLOPE FROM THE Copyright ©2022 GALLED FOR IN EXISTING WALLS, THE CONTRACTOR SHALL BRACE/SUPPORT ROOF, EAVE EDGE OF THE BUILDING. GEILING AND/OR WAPRIOR TO REMOVAL OF EXISTING WALLS, CEILING JOISTS AND Diversified Design Associates-Architects,P.C. LL ROOF RAFTERS, AND MAINTAIN SUCH CONDITION(5) UNTIL NEW HEADERS OR BEAMS PAINTING NOTES BASEMENT FLOOR All Rights Reserved. ARE INI-5TALLED AS SPECIFIED. EJECTION PUMP EJECTION PUMP EXTERIOR TRIM MUST BE PREPPED AND PAINTED AS PER MANUFACTURERS FOR FUTURE 3 THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR MAINTAINING THE STRUCTURAL REQUIREMENTS, IN OWNER SELECTED COLOR LOGABANA BATH FOR FUTURE LOWER SEAL: PROJECT NORTH: DECK BAR, SINK INTEGRITY OF THE PROJECT AT ALL TIMES. 2 ALL EXTERIOR COLUMNS AND COLUMN WRAPS MUST BE PREPPED AND PAINTED A5 - ` 4 ANY DISCREPANCIES RELATED TO THE DRAWIN65 WITH THE ACTUAL STRUCTURAL PER MANUFACTURERS REQUIREMENTS, IN OWNER SELECTED COLOR GONDITION5 THAT EXIST SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT WITH SAID WORK. 5 I ZE OF TRAPS FOR PLUMBING FIXTURES 3 IFLUMBINS 15 E =) IAORAM f . [REFER TO TABLE 1'3201.1 OF THE RESIDENTIAL CODE OF NY51 AIOO N.T.S. ARCHITECTURAL NOTES PLUMBING FIXTURELNIMUM (INCHES) I THE DUTIES OF THE ARCHITECT, BATHTUB (WITH OR WITHOUT 5HOWER HEAD HIS EMPLOYEES AND AGENTS SHALL TERMINATE WITH AND/OR WHIRLPOOL ATTACHMENTS 1 THE GOMPLETION AND DELIVERY OF CONSTRLUCTION DOCUMENTS. THE ARCHITECT HAS NOT BEEN RETAINED FOR AND 15 NOT RE5PON51131 E FOR CONSTRUCTION BIDET 1 Y4' PROJECT TITLE: 065ERVATION FOR THI5 PROJECT NOR DOES THE ARCHITECT HAVE THE AUTHORITY ADDITION & NEW DECK: TO ACT ON BEHALF OF THE OWNER. ANY DEVIATION FROM THE CONSTRUCTION GLOTHE5 WASHER STANDPIPE 2 DOCUMENTS SHALL BE PRE-APPROVED IN WRITING BY THE ARCHITECT OF RECORD. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO RETAIN A DISHWASHER (ON SEPARATE TRAP) I Y2" A55EMENT FINISHED GEILING HAYWO O D RE S ID E N C E LICENSED PROFE55IONAL TO LEGALIZE AND MAINTAIN ANY MODIFICATION TO THE CONSTRUCTION DOCUMENTS WHICH HAS NOT BEEN PRE-APPROVED BY THE FLOOR DRAIN 2" i� i� i� 2995 EUGENES ROAD ARCHITECT OF RECORD. KITCHEN 51NK ONE OR TWO TRAPS, w/OR I yea CUTCHOGUE NEW YORK 11935 W/o DI5HWA5HER 4 FOOD WASTE DISPOSER 2 THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE ACTS OR OMISSIONS OF THE LAUNDRY TUB (ONE OR MORE COMPARTMENTS) 0/20 OWNER SELECTED TEMPERED CONTRACTOR OR ANY OTHER SUBCONTRACTOR OR ANY OF THE CONTRACTOR'S OR GLASS 4 ALUM. ARGHITEGTURAL SUBCONTRACTOR'S EMPLOYEES OR A6ENT5, OR ANY OTHER PERSONS PERFORMING LAVATORY 1 Y4" HALL DRAWING TITLE: ANY Of: THE WORK. SHOWER (BASED ON THE TOTAL FLOW RATE GENERAL NOTES 3 THE ARCHITECT 15 NOT RESPONSIBLE FOR THE MEANS AND METHODS OF THROUGH 5HOWERJHEADS 4 BODY5PRAY5) n REWIRED 516N POSTING CONSTRUCTION NOR FOR SAFETY ON THE JOB SITE, AND THAT THESE FLOW RATE: RESPONSIBILITIES ARE INTENDED TO BE AND SHALL REMAIN 50LELY THE 5.1 GPM AND LE55 1 /� �� �� �� �/ �/ �/ INTERIOR ELEVATION RESPONSIBILITY OF THE GENERAL CONTRACTOR MORE THAN 5.1 GPM UP TO 12.3 GPM 2" f MORE THAN 12.3 GPM UP TO 25.8 GPM 3„ 2'--b" TEMPERED GLASS .. PLUMBING R I SER DIAGRAM RG 4 BY ACCEPTANCE OF THESE DAWINS, THE OWNER AGREES TO A55UME FULL MORE THAN 25.8 GPM UP TO 55.6 GPM 4" SLIDING DOOR RESPONSIBILITY FOR ANY DAMAGE OR SETTLEMENT, OR GRAGKING (ETC) OF NEW GON5TRUGTION AND WILL NOT HOLD THE ARCHITECT R.E5PON515LE FOR THI5 NOTE POSSIBILITY. AS PER NY5 RESIDENTIAL CODE SECTION P31032 FR05T CLOSURE. WHERE THE g1.5% 5 ALL SURVEYS, TEST BORINGS, ENGINEERING REPORTS OR OTHER 51MILAR STUDIES VALUE FOR OUTSIDE DE516N TEMPERATURE 15 O°F OR LESS, VENT EXTENSIONS DRAWN BY: 50E SHEET NO. THROUGH ROOF OR WALL. SHALL BE NOT LE55 THAN 3" IN DIA. ANY INCREASE IN THE REQUIRED FOR THE PREPARATIONS OF THESE CONSTRUCTION DOCUMENTS AND/OR REQUIRED DURING THE 505EQUENT CONSTRUCTION PHASE OF THE PROJEGT SHALL 51ZE OF THE VENT SHALL BE MADE NOT LE55 THAN I, INSIDE THE THERMAL ENVELOPE // // CHECKED BY: 5J5 BE PROVIDED BY THE OWNER. OF THE BUfLDING. BASEMENT FINISHED FLOOR EQ. EQ. EQ. EQ. EQ DATE: OI.15.24 Es Amok 0 ®� 6 ALL CONTRACTORS THAT HAVE 516NED CONTRACTS WITH THE OWNER SHALL HAVE NOTE: THE OWNER AND ARCHITECT OF RECORD LISTED A5 AN "ADDITIONAL INSURED" AND AS PER NYS RESIDENTIAL CODE SECTION P3103.1.1 ROOF EXTENSION. OPEN VENT PIPES 21'-0 I/4" V.I.F. SCALE: AS NOTED SHALL CARRY POSITIVE STATEMENT THAT THE SPECIFIC COVERAGE REQUIRED ARE THAT EXTEND THROUGH A ROOF SHALL BE TERMINATED NOT LE55 THAN 6" ABOVE THE �I ELE VAT PROVIDED. HE SHALL HOLD HARMLE55 THE ARCHITECT AND OWNER AGAINST ANY ROOF OR 6" ABOVE THE ANTICIPATED 5NOW ACCUMULATION, WHICHEVER IS GREATER. ( I TIo ION AND ALL CLAIMS ARI5ING FROM WORK PERFORMED BY HIS EMPLOYEES AND ANY 2 PROJECT N0. 221q SUBCONTRACTOR AND HIS EMPLOYEES BY ACCEPTANCE OF THESE DOCUMENTS. f, ---- ---- THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE --- --- INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER ___ ___ LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL -- ---- COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION --- ---- OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ____ -__ ANYWAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE EX15T. SPECIFIC DESCRIPTION OF THE ALTERATION. IAS PER THE NEW YORK STATE EDUCATION DN. LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) NOTES: A/C EXIST. DECK - - - - - - - - - - - - - - - - - - - O WO I \ I \ (CURBI I I ----- ----� 0 L \ H:11") (GH:I I-I Y4') I I D W. I \ L.—)3t EXIST. \ I DN. EXIST. KITCHEN EXIST. DINING I \ ROOM \ I F-- --------- (NO worms \ 15T. MUD \ ROOM \ L---------------J EXIST. \ DN. \ EXIST. GARAGE EX15T. ` >- - - - - - - - - - - - - - - - - - - -- --- BATHROOM / -- --- I / , 11 // `\ EXIST. IIII / -_- --_- -�-_-.- i� t EXIST- t------------------ EX15T. LIVING ROOM --- EX15T. HOME OF FICE (CURB (CHA'-O") : ' 3/4") EL. 0'-0" EX15T (CH:1 P-4") UP' - - - - - - - - - - - - - - - — (NO WORK) EX15T. i I li N. -- it r ------- ------- -------- -------- I I ------ ------- 2. 01.15.24 ISSUED FOR BUILDING DEPARTMENT FINISHED BASEMENT FILING 1. 11.23.22 ISSUED FOR PRELIM.BUILDING DEPT.REVIEW NO. DATE: DESCRIPTION: ISSUANCE: EX15TIN6 F IRBT F PLAN D ! V E R S ! F ! E D D E S ! G N A101 1/4" = 1'-0" I A T E S A R C H I T E C T S P . C . 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P.631.271.5400 WWW.DDANY.NET F.631.271.4844 Copyright ©2022 Diversified Design Associates-Architects,P.C. All Rights Reserved. SEAL: PROJECT NORTH: n _ PROJECT TITLE: ADDITION & NEW DECK: HAYWOOD RESIDENCE 2995 EUGENES ROAD CUTCHOGUE , NEW YORK 11935 WALL LEGEND N.T.S. DRAWING TITLE: 5L RFAGE-5N5TRADDJJACTENT TO DEMO WIMATERIALTO BE REMOVED. 5RTo MIHAT L EX I STI N6 IST FLOOR PLAN AND ALIGN FLU5H WITH EXI5TIN6. NEW WALL GON5TRUGTION: INTERIOR WALL5: U.O.N. Y2' 6YP5UM WALL BOARD OVER 2"x4" WOOD 5TUD5 ® 16"ox- EXTERIOR MALL5: U.O.N. 'HYDROGAP' HOU5E MAP A5 MANUF. BY BENJAMIN OBDYKE OVER Y2" GDX PLYWOOD OVER 2"xb" WOOD STUDS a 16" o.c. W/ 512" R-21 BATT INSULATION AND Y2" 6YP5UM WALL BOARD. DRAWN BY: 50E SHEET NO. NEM FOUNDATION WALL CHECKED BY: 5J5 EXISTING WALL CON5TRUCTION TO REMAIN DATE: 01.15.24 in OTE: SCALE: A5 NOTED ARM1 01 ALL GYP" WALLS AND CEILIN65 ARE TO BE TAPED AND 5PAGKLED (THREE COATS) AND PAINTED WITH ONE GOAT PRIMER AND TWO GOAT5 FIN15HED COLOR PROJECT N0. 2219 A5 5ELECTED BY OWNER. PROVIDE WATER RE515TANT 6YP5UM WALL BOARD IN ALL DAMP/ WET LOGATION5. THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT's SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION'ALTERED BY' FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. IAS PER THE NEW YORK STATE EDUCATION LAW ARTICLE 147-ARCHITECTURE,SECTION 7307► NOTES: 2EQ. E OP EXIST. I I --- I I I _ I 5 .xo II `,� � 12 x ( )T 12 J�v SD _ 20 < 25 28 N 13 5 I I �0 NEW INE E 23 HOME OFFICE IS 15 I 13 15 — - - - - - - — - - - - - - - - - I r--Ge�� 1O 21 la 24 �� I GENERAL UTILITY NOTE5: - - - - - - - — — — — — — — _ I I. THE HVAC, GONTRAGTOR SHALL VERIFY THE 51ZE AND PERFORMANCE OF THE EXIST. 26 I �I I EXISTING 5Y5TEM(5) AND CALCULATE THE NEW REQUIREMENTS TO DETERMINE IF THE SLAB ON — — — — — — — — — ---- - 12'-7 I/2" OI I EXISTING 5Y5TEM(5) WILL BE ADEQUATE TO ACCOMMODATE THE NEW ADDITION. IF GRADE zfi 16 — `� Q I6 Q ml + THE 5Y5TEM(S) ARE NOT ADEQUATE, THE GENERAL CONTRACTOR SHALL INCLUDE IN 13 I I -1 HI5 BID THE C05T OF EXPANDING THE 5Y5TEM(5) AS REQUIRED FOR PROPER — — — — — — — — — — — — — PERFORMANCE. - - -- - - - - S I o - - - - - - - - - - - - — - - - - - - - - - - 2. THE PLUMBING CONTRACTOR TO VERIFY THE 517E OF EXISTING DOMESTIC HOT 2. 01.15.24 ISSUED FOR BUILDING DEPARTMENT I a HOME GYMNEW I � 1 - I I WATER SYSTEM AND DETERMINE IF THE EXISTING SYSTEM WILL BE ADEQUATE FOR FINISHED BASEMENT FILING ' 14'-0 1/2"+/- NEW THE NEW AND EXISTING LOADS COMBINED. IF SYSTEM 15 NOT ADEQUATE, THE 1. 11.23.22 ISSUED FOR PRELIM.BUILDING DEPT.REVIEW UTILITY ROOM I GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE COST OF EXPANDING THE NEW -- I I7 Q 1 SYSTEM A5 REQUIRED FOR PROPER PERFORMANCE. NO. DATE: DESCRIPTION: I i 4 STORAGE --- -- I Ed 14 13 20 i 7 d) 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE 51ZE OF THE EXISTING ISSUANCE: --- -- I I ELEGTRIG SERVICE FOR ADEQUACY IN PROVIDING NEW ELECTRICAL INSTALLATIONS - I x A5 SHOWN. UPGRADE SERVICE, METER, PANEL, M. AS REQUIRED. ALL ELECTRICAL WORK TO BE FIRE UNDERWRITER5 INSPECTED AND APPROVED. SUBMIT GERTIFIGATE D ! V E R S i F i E D D E S i G N m I TO OWNER UPON RECEIPT. THE GENERAL GONTRAGTOR SHALL INCLUDE IN HI5 BID ' A T E s A R C H I T E C T S P C C dJ25 II b I THE CO5T FOR THE UPGRADE AND ALL RELATED ELEGTRIGAL REQUIREMENTS. I I 4 Lp II INTERIOR DOOR NOTE- PROVIDE AND INSTALL 50LID GORE 13/e' PRE HUNG PRIMED INTERIOR DOOR5, STYLE I = STICKING A5 SELECTED BY OWNER. PROVIDE AND INSTALL DOOR HARDWARE AS L I SELECTED BY OWNER. DOORS ADJACENT TO INTERIOR AND EXTERIOR CORNERS L — — — — — — — — — — — — — — — — — — — — — — — — — J SHALL BE 5ET 4 Y2" TO R.O. TO ALLOW FOR OWNER SELECTED TRIM. DOQR5 FOR 255 MAIN STREET SUITE 200 H U N T I N G T 0 N, NY 1 1 7 4 3 — — — — — — — — — — — — — — — — — GL05ET5, LINEN GL05ET5, PANTRIES ETC. SHALL BE GENTERED WITHIN WALL LENGTH P. 631.271.5400 14'-10 5/8"tom J4 6'-2 3/4"+/- I1'-Q" 5'-Ej" }{QLD WWW.DDANY.NET F.631.271.4844 U.Q.N. Copyright ©2022 1f2:0UN1:)AT10N W NOTE: 17'-7 1/4"+/- MIN. TRIM ALLOWANGE- PAINT GRADE AS SELECTED BY OWNER (NO MDF TRIM): Diversified Design Associates-Architects,P.C. All Rights Reserved. FLAN- ALL DIMENSION TAKEN TO GONG. POUR -5 Y2" BASE w/ SHOE MOULDING A 102 I/4" = I'-o" : SEAL: PROJECT NORTH:COMBUSTION AIR NOTECOICN57RUC71 ON N07E5 TO COMPLY WITH THE REQUIREMENTS OF NY5 RESIDENTIAL CODE CHAPTER 17 PROVIDE 'FIELD GONTROLS MODEL #GAS-4P COMBUSTION AIR SYSTEM VENT FOR UP TO 450,000 BTU/HR APPLIANCES TO BE INSTALLED A5 PER MANUF. SPEG. C1 REMOVE EXIST. WINDOW TO BE RELOCATED TO NEW HOME OFFICE; STORE 5EGURELY ON 51TELINE OF EXIST. DUGTINORK, W45TE LINE ETC. ABOVE TO BE BOXED OUT / FOR REU5E. PATCH AND REPAIR FDN. WALL TO MATCH AND ALIGN w/ EXIST. ADJACENT 15 AND FINISHED w/ GYP. BD. (MINIMUM 6-4" A.F.F. HEIGHT) LIGHT 4 VENTILATION NOTES AS PER 8303.1: LINE OF EXIST. GIRDER ABOVE TO BE BOXED OUT AS REQ'D. AND EXCEPTION #I-REQUIRED GLAZED AREA NEED NOT BE OPENA13LE WHERE MECHANICAL 16 FINISHED w/ GYP. BD. (MINIMUM 6'-4" A.F.F. HEIGHT) VENT IS PROVIDED CAPABLE OF .35 AIR GRANGE PER HOUR GONTRAGTOR TO 2 SAW CUT EXIST. FON. A5 REQ'D. TO INSTALL RELOCATED EGRESS WINDOW; PROVIDE MEGHANIGAL VENT AS PER THI5 REQUIREMENT, C� PROVIDE (2) BOX BEAM ABOVE AND 2x6 AGO. WRAPPED FRAME TO BE WRAPPED 17 REMOVE EXIST. STAIR AND REPLACE w/ NEW FLOATING STYLE STAIR TO BE IN COMPLIANCE EXCEPTION #2-6LAZED AREAS NEED NOT BE INSTALLED WHERE ARTIFIGIAL LIGHT 15 w/ ALUMINUM FOR ATTACHMENT OF WINDOW UNIT; PROVIDE WINDOW WELL TO O w/ NY5 RESIDENTIAL GORE. PROVIDE NEW 6LA55 GUARD w/ HANDRAIL TO COMPLY w/ THE PROVIDED GAPA13LE OF AVERAGE (b FOOTGANDLE5 OVER THE ROOM ® 30" A.F.F. MATCH ADJACENT RESIDENTIAL CODE OF NY5; OAK TREADS TO BE FINISHED AS SELECTED BY OWNER. SUFFICIENT LIGHTING TO COMPLY 15 TO BE PROVIDED. C� NOT USED 18 EXIST. EGRESS WINDOW TO REMAIN PROJECT TITLE: O19 OWNER SELECTED ALUMINUM AND GLASS ARGHITEGTURAL WALL w/ 2'6" WIDE x FULL NOTE: ADDITION & NEW DECK: C� EXIST. WATER FILTRATION EQUIPMENT TO REMAIN HEIGHT SLIDING BARN DOOR AT EACH END; PREP SLAB 4 HEAD AS PER MANUF. MINIMUM FINISHED CEILING HEIGHT TO BE 6' " REQUIREMENTS; COORD. w/ OWNER SELECTED MANUF. (I.E. BEAMS, GIRDERS, DUGTS) 6'-4" A.F.F. -8A.F.F;MINIMUM HEIGHT OF OB5TRUGTION5 HAYW 0 0 D RESIDENCE C� EXIST. SUMP PUMP TO REMAIN 20 INSTALL OWNER 5E1 ECTED FLOORING OVER EXIST. P. GONG. SLAB. 5LAB TO BE PREPPED AS REQ'D. PER MANUF. SPEC. w/ MOISTURE RE515TANT INSTALLATION METHODS NOTE: 2995 EUGENES ROAD OWNER SELECTED TEMPERED 6LA55 AND ALUMINUM ARCHITECTURAL NO 5LEEPING OR COOKING TO BE ALLOWED IN BASEMENT C� EXIST. ELECTRICAL PANEL TO REMAIN 21 ENGL05URE AND DOOR FOR NEW UNDER STAIR WINE STORAGE CUTCHOGUE NEW YORK 11935 INSTALL C) EXIST. HVAC, EQUIPMENT TO REMAIN 22 INSTALLATIONR SELECTED WINE STORAGE; GOORD. ANY REQ'D. BLOCKING FOR WALL LEGEND PROVIDE 'FIELD GONTROLS' MODEL #GA5-4P GOMBUSTION AIR SYSTEM VENT N'T'5' DRAWING TITLE: C) EXIST. HOT WATER HEATER TO REMAIN 23 TO BE INSTALLED AS PER MANUF. 5PEG. DUGTED TO OUTSIDE AIR WALLS/GON5TRUGTION TO BE REMOVED. PATCH/REPAIR ALL SURFACES ADJACENT TO DEMO WITH MATERIALS TO MATCH FOUNDATION PLAN �� EXIST. STEEL COL. TO REMAIN; PROVIDE OWNER SELECTED DECORATIVE WRAP 24 GOORD. DOOR LOCATION w/ REQ'D. ACCESS FOR HVAG EQUIPMENT SERVICE AND ALIGN FLUSH WITH EXISTING. _ NOTES AND DETAILS WALL TO BE SET TO CLEAR AND CONGEAL EXIST. OVERHEAD PLUMBING NEW WALL CONSTRUCTION: CIO WALL TO ALIGN w/ EXIST. STAIRWELL OPENING AB25 OVE PIPING ETC. PROVIDE ACCESS PANELS AS REQ'D. FOR GLEANOUT5 ETC. INTERIOR WALLS: U.O.N. C35/8" 20 GA. GALV. METAL STUDS ® 16" O.G. SET I" OFF FOUNDATION WALL. PROVIDE (R-15) 26 PROVIDE AND INSTALL OWNER SELECTED CLIMATE CONTROL FOR WINE STORAGE Y2" GYPSUM WALL BOARD OVER 2"x4" WOOD STUDS ® I6"o.c. 11� BATT INSULATION IN BAYS 4 Y2" GYP. BD. (TYP. OF FINISHED BASEMENT PERIMETER WALLS) 27 3/4" GLEAN FREE-DRAINING ROCK OR A6 STONE AT LEAST 12" IN WIDTH AROUND ALL FINISHED BASEMENT PERIMETER WALL: U.O.N. C12) WALL TO BE FRAMED w/ Irl/b" 20 GA. METAL STUDS ® I6 O.G.; SETY2 OFF FDN. WALL; 51DE-5 OF THE WELL. FILL TO DEPTH OF FOUNDATION FOOTING; ASSESS AND 35/8" 20 GA. GALV. METAL STUDS ® 16" O.G. SET I" OFF PROVIDE RIGID INSULATION IN BAYS PROVIDE OWNER w/ ALTERNATE PRICE TO INSTALL PUMP FOUNDATION WALL/ FOOTING A5 SHOWN. PROVIDE (R-15) BATT C13) PROVIDE Y2" SHEET ROCK GEILING OVER Ix FURRING AS REQ'D. (TYP. OF FINISHED AREAS) OWNER SELECTED EJECTION PUMP PIPED TO EXIST. WASTE LINE. INSTALL AS PER MANUF. INSULATION IN BAYS 4 Y2" MOISTURE RESISTANT GYP. BD. DRAWN BY: 5DE SHEET NO. 28 SPEC., 4 NY5 RE51DENTIAL GODS FOR FUTURE BATH AND BAR SINK- FILED UNDER 5EPERATE C14) LINE OF EXIST. WALL TO BE REMOVED (SHOWN DOTTED) APPLICATION " NEW FOUNDATION WALL CHECKED BY: 5J5 EXISTING WALL CONSTRUCTION TO REMAIN DATE: 01.15.24 A=1000'2 NOTE: SCALE: A5 NOTED ALL GYPSUM WALLS AND GEILIN65 ARE TO BE TAPED AND 5PAGKLED (THREE GOATS) AND PAINTED WITH ONE GOAT PRIMER AND TWO COATS FIN15HM COLOR PROJECT N0. 221q AS SELECTED BY OWNER. PROVIDE WATER RE-515TANT GYPSUM WALL BOARD IN ALL DAMP/ NET LOGATION5. THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY L THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT.THE Z ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL L/3 L/3 COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. � IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION D�L OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I D/4 MAX. I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING 3� ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY" i a FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE ? Q NO NOTCHES PERMITTED D/3 AX. SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION L A LAW ARTICLE 147-ARCHITECTURE,SECTION 7307) Q I 1 NOTES: FOR MEMBER5 LE55 THAN 4 IN. NOMINAL DIMENSION 2 - CANT I FORTION FLOOD? J0151- CENTER GUTS A200 I" = I'-0" L L/3 L/3 DEPTH OF TAPER APER NO NOTCHES PERMITTED GUT D/4 MAX. Q Q MEASURE AT SUPPORT GE OF w D/4 MAX. .1015 DEPTH TAPER GUT = FOR MEMBERS LE55 THAN 4 IN. NOMINAL DIMEN51ON FLOOR JOIST- END OUTS 3 CEILING J0157 TAPE GUT A200 I" = I'-0" D/3 MAX. 2" MIN. FROM TOP 8 BOT. OF J015T D (AGTUAL DEPTH) 2. 01.15.24 ISSUED FOR BUILDING DEPARTMENT FINISHED BASEMENT FILING CU771N6N I$ ORILLINIS 1. 11.23.22 ISSUED FOR PRELIM.BUILDING DEPT.REVIEW A300 r-v NO. DATE: DESCRIPTION: ISSUANCE: D ! V E R S ! F ! E D D E S ! G N n I A T E S A R C H I T E C T S P . C . 255 MAIN STREET SUITE 200 HUNTINGTON, NY 11743 P.631.271.5400 WWW.DDANY.NFT F.631.271.4844 Copyright ©2022 Diversified Design Associates-Architects,P.C. All Rights Reserved. SEAL: PROJECT NORTH: J,EXIST. FIRST FLOOR HEIGHT EL:. a_II Y4 _ . _ . _ _ _ _ PROJECT TITLE: REMOVE EX15T. WINDOW TO BE RELOCATED TO NEW ADDITION & NEW DECK: HOME OFFIGE; STORE SECURELY ON 51TE FOR REUSE. PATCH AND REPAIR FON. WALL TO MATCH AND ALIGN w/ O EXIST. ADJACENT HAYW O O D RESIDENCE_ 2995 EUGENES ROAD CUTCHOGUE , NEW YORK 11935 T. FIRST FLOOR HEIGHT EL: 0'-0" _ CD DRAWING TITLE: ------ REAR ELEVATION I I R FRAMING DETAILS O n------a I � I Q = NEW WINDOW/ DOOR 0 =EXISTING WINDOW/DOORW6� I I I ® = RELOCATED WL WINDOW/ON/ DOOR I I I I ------J L------J IL______________J I I � DRAWN BY: SDE SHEET NO. -�-------------------------------------------------------------------------------'--------=-------------------------------------------------------------------------- -� I CHECKED BY: 5,J5 DATE: 01.15.24 Am200 SCALE: ASS NOTED 1 RE,A�R ELEVAT I PROJECT NO. 22I�{ ,4200 I/4" = I'�D" ," ti THE DESIGN,DRAWINGS,SPECIFICATIONS,AND ALL OTHER DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE,AND ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT.THE DESIGNS CONTAINED HEREIN ARE INTENDED FOR THE SPECIFIC LOCATION INDICATED AND ARE NOT TO BE USED IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. THE ARCHITECT SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAINS ALL COMMON LAW,STATUTORY,AND OTHER RESERVE RIGHTS,INCLUDING COPYRIGHT. IT IS A VIOLATION OF THE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION ELECTRICAL LEGEND OF A LICENSED ARCHITECT,TO ALTER DOCUMENTS BEARING AN ARCHITECTURAL SEAL I ANY WAY. IF ANY ITEM BEARING THE SEAL OF AN ARCHITECT IS ALTERED THE ALTERING "Z" = FIXTURE DE516NATION — SEE FIXTURE TYPE BELOW ARCHITECT SHALL AFFIX SEAL TO THE ITEM ALONG WITH THE NOTATION"ALTERED BY' a a = CIRCUIT DE516NATION FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND NOTE THE SPECIFIC DESCRIPTION OF THE ALTERATION. (AS PER THE NEW YORK STATE EDUCATION � LAW ARTICLE 147-ARCHITECTURE,SECTION 7307)DUPLEX RECEPTACLE - WP INDICATES WATER PROOF �GFI DUPLEX RECEPTACLE WATER RESISTANCE GFI NOTES: QUAD RECEPTACLE -I® TV (GABLE) GONNEGTION $ SINGLE POLE 5WITGH "DECORA TYPE" SINGLE POLE DIMMER 5WITGH "DECORA TYPE" $3 3-WAY 5WITGH -DEGORA TYPE,- 4-HAY YPE"4-WAY SWITCH "DECORA TYPE" $� JAMB 5WITGH a SINGLE POLE 5WITGH W/ INDICATOR LIGHT "DECORA" PROVIDE JUNCTION BOX FOR OWNER PROVIDED A CEILING FAN (10IF INDICATED MEANS W/ LIGHT B - - 5" GE I L I N6 REGE55ED G ¢ 4"CEILING RECESSED D 40 4"GEILIN6 RECESSED w/EYEBALL E p OWNER PROVIDED WALL MOUNTED SCONCE F 0 OWNER PROVIDED VANITY WALL MOUNTED LIGHT GJO JUNCTION BOX FOR OWNER PROVIDED HANGING FIXTURE H -( 4" RECESSED w/ SHOWER LEN5E 1 OWNER PROVIDED EXTERIOR WALL MOUNTED LIGHT OWNER PROVIDED CHANDELIER J O (mp) INDICATES MOTOR POWERED LOWERING DEVICE WIRED TO SEPARATE 5WITGH K 0 OWNER SELECTED HANGING PENDANT LIGHT L -----♦ UNDER CABINET LED LIGHT 1„1 4 Ft. LED STRIP LIGHT W/ COVER N CEILING MOUNTED PORCELAIN FIXTURE O CABINET LIGHT P ------ UNDER CABINET LED TAPE LIGHTING Q2. 01.15.24 ISSUED FOR BUILDING DEPARTMENT OWNER PROVIDED ARTWORK LIGHTING FINISHED BASEMENT FILING R OWNER PROVIDED SURFACE MOUNTED LIGHT 1. 11.23.22 ISSUED FOR PRELIM.BUILDING DEPT.REVIEW O NO. DATE: DESCRIPTION: 5 o OWNER PROVIDED LED LIGHT BAR WITH COVER ISSUANCE: _J TOILET EXHAUST FAN CONNECTED TO LIGHT 5WITGH (It) IF INDICATED MEANS WITH LIGHT D ! V E R S ! F ! E D D E S ! G N :,.. I A T E S A R C H I T E NOTE: C T S P . C . PROVIDE DIMMERS ON ALL SWITCHES WHENEVER P0551BLE NOTE: ELECTRICAL CONTRACTOR TO REVIEW LIGHTING AND 5WITGHING LAYOUT WITH CLIENT IN FIELD PRIOR TO INSTALLATION 255 MAIN STREET • SUITE 200 • HUNTINGTON, NY 11743 P.631.271.5400 WWW.DDANY.NET F.631.271.4844 NOTE: Copyright ©2022 ELECTRICAL CONTRACTOR TO COORDINATE ANY ADDITIONAL Diversified Design Associates-Architects,P.C. EXTERIOR LIGHTING REQUIREMENT5 WITH OWNER g All Rights Reserved. SEAL: PROJECT NORTH: UTILITY NOTES: I. THE HVAG CONTRACTOR SHALL VERIFY THE 51ZE AND PERFORMANGE OF THE EXISTING SY5TEM(5) AND CALCULATE THE NEW REQUIREMENTS TO DETERMINE IF THE EXI5TIN6 � — _ _ 5Y5TEM(5) WILL BE ADEQUATE TO ACCOMMODATE THE NEW 1 0 O ADDITION. IF THE SY5TEM(5) ARE NOT ADEQUATE, THE C GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE COST / \ OFRFORMA IN6 THE 5Y5TEM(S) AS REQUIRED FOR PROPER 0 / EDW l� \ M HOME OFFICE ) 2. THE PLUMBING CONTRACTOR TO VERIFY THE 51ZE OF / GG C�— \ EXI5TING DOMESTIC HOT WATER SYSTEM AND DETERMINE IF PROJECT TITLE: G G — — G THE EXISTING SYSTEM WILL BE ADEQUATE FOR THE NEW AND ADDITION & NEW DECK: EXI5TING LOADS COMBINED. IF SYSTEM 15 NOT ADEQUATE, THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BID THE i _ ` ; G05T OF EXPANDING THE SYSTEM AS REQUIRED FOR PROPER HAYW 0 0 D RESIDENCE I WINE / / PERFORMANCE. I _____ T E 2995 EUGENES ROAD 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE 517E OF CUTCHOGUE , NEW YORK 11935 1 --_--- IN PPEIDING NEW ELX15TIN6 El ECTRICAL INSTIG SERVICEFALLATIONS OR ASY RSHOWN. / UPGRADE SERVICE, METER, PANEL, ETC. AS REQUIRED. ALL NEH ELECTRICAL WORK TO BE FIRE UNDERWRITER5 INSPECTED DRAWING TITLE: HOME GYM \\ AND APPROVED. SUBMIT CERTIFICATE TO OWNER UPON NEW RECEIPT. THE GENERAL CONTRACTOR SHALL INCLUDE IN HI5 BASEMENT LIGHTING UTILITY ROOM�I BID THE COST FOR THE UPGRADE AND ALL RELATED ELEGTRIGAL REQUIREMENTS. ELECTRICAL PLAN IJ 1 1 W M - - -- G / M ELECTRICAL NOTE- NE / PROVIDE ALL ELECTRICAL OUTLETS, ¢ SWITCHES ETC. LO I ACCORDING TO ALL STATE AND LOCAL CODES. 5TORA6E / COORDINATE WITH OWNER, LOCATIONS OF ALL ADDITIONAL O ILP ( G�^ C� 5WITGHING, OUTLETS AND LIGHTING. I- PROVIDE ELECTRICAL CONVENIENCE RECEPTAGLE OUTLETS PER E3Q01. COORDINATE WITH OWNER DRAWN BY: 50E SHEET NO. IN. £ ADDITIONAL REQUIREMENTS. 2- PROVIDE CONVENIENCE RECEPTACLE OUTLET IN CHECKED BY: 5,J5 GARAGE, PER E3401A WITH GFCI, PER E3c102.2 DATE: 01.15.24 3— PROVIDE ONE WALL 5WITGH CONTROLLED LIGHTING ON Eml THE EXTERIOR 51DE OF EACH OUTDOOR E61RE55 DOOR SCALE: A5 NOTED HAVING GRADE LEVEL ACCESS IN ACCORDANCE WITH E3G033 BASEMENT LI &HTIN& I$ ELECTRICAL FLAN 4- GFGI's ARE TO BE PROVIDED, PER E3402 PROJECT NO. 221q F-100 1/4" :: 1'-0"