Loading...
HomeMy WebLinkAbout49536-Z o�oS�FFali�coG Town of Southold 10/21/2023 P.O.Box 1179 53095 Main Rd • Southold,New York 11971 'T xfzrar,'� r CERTIFICATE OF OCCUPANCY No: 44682 Date: 10/21/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2300 Grand Ave,Mattituck Mattituck SCTM#: 473889 Sec/Block/Lot: 107.-2-9.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/15/2023 pursuant to which Building Permit No. 49536 dated 8/1/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Mercurio,Nicole of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49536 10/4/2023 PLUMBERS CERTIFICATION DATED Aut ori Signature v =� TOWN OF SOUTHOLD �o�suEFotK o� cay� BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • � h SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49536 Date: 8/1/2023 Permission is hereby granted to: Mercurio, Nicole 2300 Grand Ave Mattituck, NY 11952 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 2300 Grand Ave, Mattituck SCTM #473889 Sec/Block/Lot# 107.-2-9.2 Pursuant to application dated 6/15/2023 and approved by the Building Inspector. To expire on 1/30/2025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Buil Spector oF so�ryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 aQ sean.deviin(aD-town.southold.ny.us Southold,NY 11971-0959 COUn�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Nicole Mercurio Address: 2300 Grand Ave city:Mattituck st: NY zip: 11952 Building,Permit#: 49536 Section: 107 Block: 2 Lot: 9.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor Basement Solar X Commerical X Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition X Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency StrobeHeat Detectors Disconnect 40A Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 10.4kW Roof Mounted PV Solar Energy System w/ (26) Qcell qpeak ML-G10 40OW Modules, Combiner Panel w/22W, 40A Fused Disconnect Notes: Solar C Inspector Signature: Date: October 4, 2023 S. Devlin-Cert Electrical Compliance Form OE SOUIHp # # TOWN OF SOUTHOLD BUILDING DEPT. �p • �o `yco 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [✓r FINAL - [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 0I - 'a �Z- "( LJ � r DATE �' ��" d23 INSPECTOR OE 50UlyO� # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) WLECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:iaq a e 1 ro /o /v DATE e- IE-�2-- INSPECTOR ` - # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL la REMARKS: So T' t"� c�7' �� S�U� �USGOvJdfL�G lay, ab AU� DATE 02 C �3 INSPECTOR OF SOOIy�� * * TOWN OF SOUTHOLD BUILDIN DEPT. `ycourm��'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [. ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) •[,� ELECTRICAL (FINAL) [ ] CODE VIOLATION /[ -] PRE C/O [ ] RENTAL REMARKS: DATE Ia INSPECTOR MELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) �] ------------------------------------- FOUNDATION -------------------------- ------FOUNDATION (2ND) No 0 H ROUGH FRAMING& .� PLUMBING Q- je INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS Vu A 0a a ' �, � VZ3 Ve a r\ C Z a x o � N H x x d b H �o�gUFFOI��OGy2 TOWN OF SOUTHOLD —BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502https://www.southoldtownnx ov f Date Received APPLICATION FOR BUILDING PERMIT S3�For Office Use Only 3 �� L=i :us� � � �fjf PERMIT NO. Building Inspector: JUN 1 5 2023 Applications and forms'must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an _ Owner's Authorization form(Page 2)shall be completed. 'R, h```•% ""`` Date: (a I 0 a 3 OWNER(S)OF PROPERTY: Name: Nicole Mercurio SCTM# 1000- 473889107.-2-9.2 Project Address: 230 Grand Ave Phone#: 516-375-0188 Email: Mailing Address: CONTACT PERSON: Name: Lorraine Dipenta Mailing Address: 7470 Sound Ave.,Mattituck, NY 11952 Phone#: 631-779-7993 Email: lorraine.dipenta@e2sys.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: ` Name: Element Energy LLC Mailing Address: 7470 Sound Ave.,Mattituck,NY 11952 Phone#: 631-779-7993 Email: permits@e2sys.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: t/Other 10.4 Kw 26 QCELL Q.PEAK DUO BLK ML-G10+400 $ 35,000.00 Will the lot be re-graded? ❑Yes ✓No Will excess fill be removed from premises? ❑Yes ✓ No 1 PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Residential Zone AC this property? ❑Yes ✓No IF YES, PROVIDE A COPY. I✓,Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Lorraine DiPenta ✓Authorized Agent ❑Owner Signature of Applicant: C4 Date: Jun 15 2023 STATE OF NEW YORK) SS: COUNTYOF Suffolk ) Lorraine DiPenta being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor/Agent (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of -Lne— , 20 Notary Public DEBRA A SEPULVEDA NOTARY PUBLIC,STATE OF NEW PORI[ RegistradonNo.O1SiAUW PROPEF TY OWNER AUTHORIZATION Qualiffied on Expires ffo ik Commission ExCour ( erethe applicant is not the owner) I� Nicole Mercurio residing at 2300 Grand Ave, Mattituck, NY 11952 do hereby authorize Element Energy LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. Jun 15 2023 Owner's Signature Date Nicole Mercurio Print Owner's Name 2 �`%j"S11ffOtk Yy BUILDING DEPARTMENT- Electrical Inspector s v� CO TOWN OF SOUTHOLD f N = F4 Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 �Ol,FX. Telephone (631) 765-1802 - FAX (631) 765-9502 f � ' rogerr@southoldtownny..gov — seanclCcD-southoldtownn -gov APPLICATION FOR ELECTRICAL INSPECTION' ELECTRICIAN INFORMATION (All Information Required) Date: Jun 15 2023 Company Name: Element Energy LLC Name: Jamie Minnick License No.: 52689-ME email: permits@e2sys.com Address: 7470 Sound Ave., Mattituck, NY 11952 Phone No.: 631-779-7993 JOB SITE INFORMATION (All Information Required) Name: Nicole Mercurio Address: 2300 Grand Ave, Mattituck, NY 11952 Cross Street: Phone No.: 5.16-375-0188 Bldg.Permit#: ��G�j�,b email: Tax Map District: 1000 Section: 1.07 Block: .2 Lot: 9.2 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Flush roof mounted solar_pv system-10.4 Kw 26 QCELL Q.PEAK DUO 13LK ML-G10+400 26-IQ8PLUS-72-2-US Circle All That Apply: Is job ready for inspection?: ✓ / NO Rough In Final Do you need a Temp Certificate?: NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Form.xls NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE a- .a A^^A^ 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 95991 07/13/2022 TO 07/13/2023 7/19/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' .COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/IWWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE,PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SUR NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 126776733 CERTIFICATE OF LIABILITY INSURANCE DATE(MM7/2'1/20�2 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERT S.FEDE INSURANCE AGENCY PHONE bi 1- - FAX - IC o t• AIC No): 23 GREEN STREET,SUITE 102 E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS. FEDE INSURANCE INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURER B:STATE INSURANCE FUND 523930 Element Energy LLC INSURERC: PUINT POINT 81434 ELEMENT ENERGY SYSTEMS INSURER D: ENERAL TAR MANA EMENT O. 7470 SOUND AVENUE INSURERE: MATTITUCK, NY 11952 INSURER F: COVERAGES' CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR S POLICY NUMBER MM/DDIYYYY MMIDDIYYYY COMMERCIAL GENERAL LIABILITY CL00275204 EACH OCCURRENCE $ 3,000,000 A X X 7/14/2022 7/14/2023 DAMAGE TO RENTED CLAIMS-MADE � OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 5000 X Contractual Lia #D IMA389203A 7/14/2022 7/14/2023 PERSONAL 8 ADV INJURY $ 3000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 3,000,000 PRO- LOC PRODUCTS-COMP/OP AGG $ OO POLICY n OOO OTHER: AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EEXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION 124494445 PER OTH- AND EMPLOYERS'LIABILITY Y/N 7/13/2022 7/13/2023 STATUTE I I ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 B OFFICERIMEMBER EXCLUDED? FX I N/A ' (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ 1-000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ NY State DBL DBL5s75z7 1/01/2022 1/01/2023 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 MAIN ROAD THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. SOUTHOLD, NY 11971 AUTHORIZED REPRESENTATIVE 203E2.r S FEDE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD EW TA Compensation workers' CERTIFICATE OF INSURANCE COVERAGE STATE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured Work Location of Insured (Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e., Wrap-Up Policy) 823336604 2. Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b. Policy Number of Entity Listed in Box 1 a" SOUTHOLD, NY 11971 DBL567527 3c.Policy effective period 01/01/2022 to 12/31,12M 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/20/2022 By Aha/ Gf (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 46,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 46,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DS-120.1 (12-21) 111111111 °°°°°°1°1°1°°111111°°1°°°�IIIIIII Zoho Sign Document ID:2A768FFA-PMSGAXFXMUDLL7HQVA3Wl4EPQ330SIM4DINHHWH5XGU DESIGN k DRAFTING BY: 50LAP ARRAY ON MAIN HOUSE 10.4 kW ELEMENT ENERGY LLC (26)QCELL Q.PEAK DUO 13LK ML-G 10+400 WATT PV MODULES (2)STRINGS OF(1 3)MICRO-INVERTERS REVIEW BY J.M.NABCEP CERTIFIE '(2)STRINGS TOTAL 051112-129 TO UTILITY GRID PEV1510N5 STRING #IF FI,I, DATE REV r- ------------------- ,tOO A G� a DESCRIPTION N ORIGINAL 05-01-2023 BI-DIRECTIONAL I * * O UTILITY METER 1- ------------------- a•r_ PHASE.240 V 1 I y 2 1 N i Nu✓r C7 4' I POINT OF INTERCONNECTION X0340 R(j PER NEC 240.21(13)(1)6 690.64(A) TAP CO STRING #2 A`�o�SStoNP� 5 ANLL NOT EXC EDN O FTOK5 Zll CONTRACTOR I ---- ------ ------ ------ -- -- -_ MAIN SEPVICEDI N ENPHA5E BRANCH MICRO-INVERTER CIRCUIT CABLE TYPICALELEMENT ENERGY, LLC. ENPHASE I08PLU5-72-2-U5 240 VAC. 1.21 A 7470 SOUND AVE 97%CEC-WEIGHTED EFF. I ENPNA5E AC COMBINER 4 AC DISCONNECT NEMA 6.UL LISTED MATTITUCK, NY 1195 , � 240 VAC.80 A TYPICAL I GATEN Y I� NEMA 3R.UL L15TED 50 D D223NRB LICENSE # 6746 I-111 (2)20 A DOUBLE POLE BREAKERS 240 VAC.GO A LICENSE# 52G(59-ME (1)15 A DOUBLE POLE BREAKER .I^ -')R GATENAY/COMMUNICATION DEVIL..` NEMA 3R.UL LISTED V _ I I G N L I I G V �_ I I (2)40 A FUSES TTT, 20A I 20A I 15A I I I 40A I PROJECT NAME , MAIN SERVICE PANEL I N N , I-PM.3-W G N L LI r __ G ---_- G _______________________________________ 240 VAC ____------ , 200A I I N W �J N G - U Lo I I I I zzo> I I I I I GROUNDING LLJ W CTRO 5Y5TEMQ \ ELECTRODE I I i Q I V J LU C Z I Z ------------------------------------- -------------� WIRE CONDUIT SCHEDULE 0 U CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop I.D.# ORIGIN DESTINATION 51ZE PER POLE QUANTITY DERATE INSULATION 51ZE QUANTITY INSULATION (CU/AL) TYPE 51ZE TEMP DERATE DISTANCE. O 1- 310.)5(B)(3) 3 10.1 5(B)(2a)/(3c) I INVERTERS COMBINER PANEL AWG#12 1 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I" 55QC 0.84 80 FT 2.0% C) OR EMT W (() Q 2 COMBINER PANEL AC DISCONNECT AWG#(5 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I,, 459C 0.95 25 FT 0.5% N 3 AC DISCONNECT MAIN PANEL AWG#6 I 3 . 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 452C 0.95 10 FT 0.2% ELECTRICAL NOTES - � SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS -.� )� � \`iJ � � \� 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acct Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90QC WET ENVIRONMENT. [NEC 690.8(13)(1)]: (Isc)'(#ofstrin s)'(I.56)= 19.66 A -LINE DIA. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 9 Modules per String 13 1 / AWG#12,ampacity'Temp Derate= 20.1 6 A TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. 20.I6 A> 19.66 A,therefore DC wire size is valid. Modules per Inverter I SEP 2 7 2023 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 26 COMPLY WITH NEC 110.26. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) =39.33 A Record low temp -109C FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE550RIE5 TO FULFILL AWG#8,ampaclty'(Temp Derate)'(Conduit Fill Derate)= 52.25 A Voc Temp Coefficient -0.24%lQC DRAWING SCALE APPLICABLE CODES AND STANDARDS. 52.25 A>39.33 A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS B DUiv DEPT. 6.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation 4,q_ ; THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. Inverter Max Amperage output' (1.25) = 39.33 A O eratm Current 10.8 A '�'�$;, t, . 3 ,: � ,4`:; N .T.S. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#6,ampaclty'(Temp Derate)'(Conduit Fill Derate)= 71.25 A Operatinq Voltacle 37.1 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A>39.33 A, therefore AC wire size is valid. Max.System Voltage 49.6 V SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 13.9 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEK LUG OR I1-SCO G5L-4DBT LAY-IN LUG. AC SYSTEM SPECIFICATIONS SHEET NUMBER I O.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) Max AC Output Current 39.33 A p\ �_ OR O eratm AC Volta e 240 V I �/ 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000- 107-2-0.2 Zoho Sign Document ID:2A768FFA-RUKHYDKYUARYI9C)CUZWSPCYOZ7YWN7XWGZ8EOTL3BEUO °. Town of Southold May 1st, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Mercurio Residence, 2300 Grand Ave. Mattituck, NY 11952 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.9 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. 0F: NEIVr Great Eastern Services, Inc. ,�Q- o A c�G 0 PO Box 240 24 Harvey Rd 0 Riverhead, NY 11901 �` z Mobile: 631.235.0189 X03443 Email: jerrygiustra@gmail.com 'ORp�SS% Zoho Sign Document ID:2A768FFA-RUKHYDKYCARY190GZWSPCYOZ7YWN7XWGZ8EOTL3BEUO 9 d 'SCOPE OF WORK :DE51GNRA`TINGBY: Shelter Island ENERGY LLC TO INSTALL A 10.4 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE MERCURIO RESIDENCE, Hei. 0 fREVINABCEP CERTIFIE LOCATED AT 2300 GRAND AVE, MATTITUCK, NY 1 1952. / / ZS THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID '§outhold// Shelterlslan THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. �y i I_ r y. REVISIONS Pernmc// DE5CRIPTI0N DATE REV 5Y5TEMRATING J�.�L OR GINAL 05-0 1-2023 10.4 kW DC STC / Cutchoo uel No � G r_M ""ucic �•. New Suffolk � f EQUIPMENT SUMMARY Lau" � 2G QCELL Q.PEAK DUO ELK ML-G 10+400 WATT PV MODULES 2G ENPHASE IQ8PLUS-72-2-US MICRO INVERTERS ® � CONTRACTOR I IRONRIDGE XP 100 MOUNTING SYSTEM _,amedpon SKEET INDEX qua lso -''/ L JAIAESPaai ('jl�` .�--.• North SA ° _ 9 i ELEMENT ENERGY, LLC. PV-I COVER 7470 SOUND AVE LOCATION CT AI PROJ PV-2 SITE PLAN EMATTITUCK, NY 1195 PV-3 ROOF PV LAYOUT - PV-4 STRUCTURAL/DETAILS 4.SECTIONS LICENSE # G74G I-HI PV-5 3-LINE ELECTRICAL DIAGRAM LICENSE # 52G89-ME PV-G LABELS N GOVERNING CODES o° OF NEI�y� . 2017 NATIONAL ELECTRICAL CODE. �� G7 O ' * 2020 RESIDENTIAL CODE OF NEW YORK STATE. 0 A PROJECT NAME�P Gs ,per `} . 2020 FIRE CODE OF NEW YORK STATE. �_ W 270°-==:3 0900 E A5CE 7-I G AND NEPA-70. UNDERWRITERS LABORATORIES(UL)STANDARDS 05HA 29 CFR 1910.269 240 V 120° W LLJ C\1 GENERAL NOTES 2��0 0 4 � 210°180150° LLJ W z Ln_ 1 . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT ARo SS1oNPELE%TRICAL r" > _ THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZEINSPECTION REQUIRED (n Q HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK W I) Z AGREE THE SAME. AERIAL VIEW IL/ Z 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED Q Q U APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP — INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, U AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES COMPLY WITH ALL CODES F U C) F- 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND RIOR TO ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PNEW YORK STATE & TOWN CODES O . .VEDASNOT AS REQUIRED AND CONDITIONS F JURISDICTION. COMMENCING WITH WORKAP O LLJ (-f) Q 4. IF I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR IN THE COURSE OF CONSTRUCTION CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE DATE: B.P. WHICH DISAGREES WITH THAT AS INDICATED D ON THESE PLANS, '#� THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS TLU�}NA AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND FEE:-: l= ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND CHEALTH ADMINISTRATION.THIS SHALL INCLUDE, BUT ARE NOT BY' S tANNIN BO CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, NOTIFY:BUILDING DEPARTMENT AT RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY F 765.1802 SAM TO 4 PM' FOR THE S INOLD TO' d TRUSTEE SHEET NAME 5.FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 ALL STRUCTURAL STEEL SHALL BE AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT FOLLOWING.INSPECTIONS:- SPECIFICATIONS. — — LATECONSTRUCTION. I. FOUNDATION - TWO REQUICOVER 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING FOR POURED CONCRETE RED UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 2. ROUGH - FRAMING & PLUMBING OCCUIPA CY OR NYS CODES 1I:REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND 3. INSULATION. 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. I CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 4. FINAL. =CONSTRUti TION MUST USE IS UNLAWFUL DRAWING SCALE 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS CERTIFICATION OF THESE PLANS. BE COMPLETE ;:C1R C.O., r.. 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON ALL CONSTRUCTI� WITHOUT-CERTIFICATI N .T..5. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. N SHALL MEET THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK,THE SITE TO BE CLEARED REQUIREMENTS OF THE CODES OF NEW C /� ^+ p THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS.THE FACILITY IS TO BE YORK STATE. NOT RESPONSIBLE FOR �r�vC1vUrNCY LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THIS PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF DESIGN OR CONSTRUCTION ERRORS. 511EET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS PV- I RESULT OF HIS WORK. TAX MAP: 1000- 107-2-9.2 Zoho Sign Document ID:2A768FFA-RUKHYDKYCARY190GZWSPCYOZ7YWN7XWGZ8EOTL3BEUO LEGEND o EXISTING UTILITY METER DESIGN E DRAFTING BY: MAIN SERVICE PANEL NEW PDI SUB-PANEELEMENT ENERGY LLC LS A/C DISCONNECT REVIEW BY J.M.NABCEP CERTIFIE COMBINER 051 1 1 2-1 29 INVERTERS /� GND ELECTRODE 'Y ME 00 REVISIONS PV MODULE �/�� , DESCRIPTION DATE REV RACKING RAR. "1�2 joo ORIGINAL OS-OI-2023 o ATTACHMENT POINT ---RAFTERS 240 0 PROOF PITCH ANGLE 4`90.0 �SUNRUN METER 2'00 120- ®VENT / 1800160, OPLUMBING VENT S ®SKY LIGHT ®CHIMNEY COMPOSITE SHINGLES T CONTRACTOR GOOD OO CONDITION �POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY 1 81-93n `Y Acce55 RooF ELEMENT ENERGY, LLC. ;A 7470 SOUND AVE MATTITUCK, NY 1 195 LICENSE # G74G I-111 LICENSE # 52G(59-ME FEE jPROJECT NAME W W N zzm w w — o > — Q A / Boz 321-211 U A O — LIJ 0 � N < SPIFFY NAME OF NEFIV ° A SITE PLAN 'NOTE 1 .)THE ROOF 5ETBACK/PATHWAY SHALL NOT BE r— REQUIRED TO ROOFS WHEN OPPOSING OR1 51-9 2 ADJACENT ROOF 15 ACCESS34>ROOF IN �O 10 43 ` DRAWING SCALE ACCORDANCE WITH K324.G.I EXCEPTION OF A R1/611 I I-O II 2020 NYS RESIDENTIAL CODE. O ss+oNP�" —— CONSTRUCTION NOTES 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. SHEET NUMBER 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. PV-2 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000-107-2-9.2 Zoho Sign Document ID:2A768FFA-RUKHYDKYCARY190GZWSPCYOZ7YWN7XWGZSEOTL3BEUO CON5TRUCTION SUMMARY DESIGN e DRAFTING BY: (2G) QCELL Q.PEAK DUO BLK Ml--G 10+ 400 WATT PV MODULES ELEMENT ENERGY LLC (DIMENSIONS: 74"X 4 1 .I"X 1 .3") REVIEW BY J.M.NABCEP CERTIFIE (2G) ENPHASE IQ8PLUS-72-2-U5 MICRO INVERTERS tv 051112-129 (54) ATTACHMENT POINTS @ G4"O.C. MAX. 0°o (235.1) LF IRONRIDGE XR 100 MOUNTING SYSTEM. REVISIONS ROOF TYPE: ASPHALT SHINGLE (SINGLE LAYER) , �2�0° DESCRIPTION DATE REV CONSTRUCTION NOTES p ORIGINAL 05-01-2023 1 .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 1 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. '2 X 90°� 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 210° MINIMUM NEMA 3K RATING. F 2C)LX80°iso° 720° 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE S FIELD VERIFICATION. 'NOTE 1 .)THE ROOF SETBACK/PATHWAY SHALL NOT BE REQUIRED TO ROOFS WHEN OPPOSING OR CONTRACTOR ADJACENT ROOF IS ACCESS ROOF IN ACCORDANCE WITH R324.G.I EXCEPTION OF ARRAY#2 rCL, 2020 NYS RESIDENTIAL CODE. �I.OMOQUL"ESA z�Plrc �N ELEMENT ENERGY, LLC. 24G°AZIMUTH r� 7470 SOUND AVE ACCESS ROOF MATTITUCK, NY 1 1952 29 LICENSE # 52@89-ME PROJECT NAME W W N 10/1 U � Ln z z m W W — E) > — Fn Q hoz ARRAY#I i L6 MQDULES � 5 RooF20'PITCH O 246°AZIMUTH �(p) LU LEGEND MAISTING UTILITY METER N SERVICE PANEL / NEW PV SUB—PANELS OCMBINER DISCONNECT OF NEVV INVERTERS � �V yO SHEET NAME GND ELECTRODE ,r\P�PEtO A GAG .fN W.MPV MODULE ( ROOF DETAI s RACIONG RAIL / j r �' LLJ � 0 ATTACHMENT POINT / N ---RAFTERS � = DRAWING SCAM -*--ROOF PITCH ANGLE 21-411J 70g443 A R9SUNRUN METER �O SSIO`P I/QII = I I—OII ®�T CJ 0PLUMBING VENT ®SKY LIGHT ® SHEET NUM BER CHIMNEY ®COMPOSITE SHINGLES P V/—3 GOOD CONDITION �POTENTIAL SHADING ISSUES ,RIM/REMOVE AS NECESSARY TAX MAP: 1000- 107-2-9.2 Zoho Sign Document ID:2A768FFA-RUKHYDKYCARY190GZWSPCYOZ7YWN7XWGZ8EOTL3BEUO LOAD CALCOLATION ARRAY#I ARRAY#2 ITEM DE5CRIPTION ARRAYS#1-2 DESIGN b DRAFTING BY: RD Rid e Beam/Board 2"X 10" D. FIR ELEMENT ENERGY LLC MODULE WEIGHT(Lbs) 48.4 48.4 R Roof Rafters 2"X 8" D. FIR I G"O.C. REVIEW BY J.M.NABCEP CERTIFIE (D) Deckln 5/8"CDX PLYWOOD 05 1 1 1 2-1 29 #OF MODULES 1 G 10 (C) Collar Ties 2"X 4" D. FIR @ 48"O.C. TOTAL MODULE WEIGHT(Lbs) 774.4 484.0 r J Cedin Joist 2"X G" D. FIR I G"O.C. REVISIONS or NEW (P) Pitch 204 DESCRIPTION DATE REV TOTAL LENGTH OF RAIL(Ft) 110.9 124.2 �(` v � 11 Horizontal S an of R 203" MAX. ORIGINAL 05-01-2023 RAIL WEIGHT PER FOOT(Lbs) O.G8 0.68 *���o A TOTAL RAIL WEIGHT(Lbs) 75.4 84.5 /�` 1 / #OF 5TRANDOFF5 24 30 m , W WEIGHT PER STRANDOFF(Lbs) 2 2 (D) TOTAL STANDOFF WEIGHT(Lbs) 48 GO t 103443 TOTAL ARRAY WEIGHT(Lbs) 897.8 628.5 AR�FESStioNP� POINT LOAD(Lbs) 37.4 20.9 CONTRACTOR TOTAL ARRAY AREA(Sq Ft) 342.6 2 14.1 ARRAY DEAD LOAD(Lb5/5q Ft) 2.G 2.9 ELEMENT ENERGY, LLC. WIND DESIGN SUBJECTTO DAMAGE FROM 7470 SOUND AVE GROUND SEISMIC WINTER ICE BARRIER AIR MEAN SNOW Speedd Topographic Special Wmdbome DESIGN Frost DESIGN UNDERLAYMENT FLOOD FREEZING ANNUAL / MATTITUCK, NY 1195 LOAD° (mph) effedsk wind debris CATEGORYf Weatheringa line Termite` TEMPe REQUIREDh HAZARDS9 INDEX' TEMPI (C) LICENSE # G74G I-HI region' zone'" depthb LICENSE# 52@89-ME 20 140 NO NO NO B SEVERE 3 FT HEAVY 15°F YES F E X 599 51*F MANUALJ DESIGN CRITERIA° Winter Summer Altitude Indoor Design Heating heating cooling correction factor Elevation Latitude des' s p /�1 PROJECT NAME temperature ling t ure temperature coodifference 108 FT 41"N 15°F 86°F 1.00 70°F 75"F 55°F /J 1 r�' CoolingWind Wind 1 / W LLJ `V velocity velocity Coincident Daily Winter Summer temperature difference heating cooling wet bulb range humidity humidity — U Ln zzm 11°F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GR @50%RH W LL_j For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL n C) / a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strengthLl I Q z required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. z b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction O Q shall fill in the frost line depth column with the minimum depth of footing below finish grade. MODULE MOUNTING CLAMP Q�J U C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. JL/ d. The jurisdiction shall fill in this partof the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure categoryshall be determined O on a site-specific basis in accordance with Section R301.2.1.4. SOLAR MODULE e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York " C State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also STAINLESS STEEL 3/8 m see Figure R301.2(1).] BOLT AND NUT LL[ Q f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. N g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: NRIDGE ALUMINUM RAIL L The accompanying Flood Insurance Rate Map(FIRM), R.Flood Boundary and Floodway Map(FBFM),and ALUMINUM"L"BRACKET iii.Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. SHEET NAME h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ALUMINUM F=LASHING effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." STI\U CT U RA A . The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32"F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method (Base 32°F)." CEDAR SHINGLE ROOF It. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 5/16"x 6"STAINLESS jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. STEEL LAG BOLT WITH DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with 2 I/2"MIN THREAD "YES"and identify any speck requirements.Otherwise,the jurisdiction shall indicate cis this part of the table. PENETRATION SEALED table. AS NOTE D m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the WITH GEOCEL 4500 n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or lb from ACCA Manual J or established criteria determined by the (EQUIVALENT OR BETTER) jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. SHEET NUMBER (') See Figure R301.2(4)B. PV-4 TAX MAP: 1000- 107-2-9.2 MOUNTING DETAIL n Zoho Sign Document ID:2A768FFA-RUKHYDKYCARY190GZWSPCYOZ7YWN7XWGZ8EOTL3BEUO SOLAR ARRAY ON MAIN HOUSE 5.2 kW DESIGN 4 DRAFTING BY: (13)QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULES ELEMENT ENERGY LLC (1)STRING OF(1 3)MICRO-INVERTERS -(I)STRING TOTAL REVIEW BY J.M.NCERTIFIE 051112-129 TO UTILITY GRID STRING #I REVISIONS r- ------------ t N DESCRIPTION DATE REV BI-DIRECTIONAL 'T LITY METER I-PHASE. ORIGINAL I 1 PI240 1 LJ V I 1 N I ENPHASE BRANCH POINT OF INTERCONNECTION I CIRCUIT CABLE TYPICAL MICRO-INVERTER PER NEC 240.21(8)(1)t G90.G4(A) I ENPHA5E 1Q81"LU5-72-2-1-15 LENGTH OF TAP CONDUCTORS 240 VAC. 1.21 A SHALL NOT EXCEED 10 FT 1 97%CEG-WEIGHTED EFF. ! OF N E w NEVA G I TYPICAL U �Q� L LISTED QQ A Co I �3 I I = � (9 MAIN SERVICE D15CONKIECT CONTRACTOR r Q� m 240 V.200 A I ' ELEMENT ENERGY, LLC. SOA 10344' 1 7470 SOUND AVE AC DISCONNECT S1 MATTITUCK, NY 1 1052 SQ D D223NRB 240 VAC.GOA LICENSE # G74G 1-HI NEMA 3R.ILL 1-15TED t LICENSE # 52G89-ME (2)20 A FI-5E5 I 1 0A 20A I t 1 1 I I I MAIN SERVICE PANEL � N N PROJECT NAME I-Pri.3-W I 240 VAC r----_--_--- C -_--- G ----------------------------------- _--_-_---_------- 200A I AC COMBINER BOX j I N /� 240 VAC.80 A I I G _1 W W N NEMA 3R UL U5TED G N =(1) E POLE BP,EN.ER I I I i V D L1/ ( I I I I EXISTING GROUNDING z Z I I ELECTRODE SYSTEM W LL_J - �- _ > - zL. W^/ oz L------------------------------------- -------------J z WIRE CONDUIT SCHEDULE O CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% C� 5 I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE 51ZE TEMP DISTANCE U�31ODERATE .-5(8)(20(3c) I INVERTERS COMBINER PANEL AWG#12 1 2 1 USE-2/PV Wire AWG#8 1 BARE CU FREE AIR I" 559C 0.84 1 10 FT 0.5% q OR EMT LLJ 2 COMBINER PANEL AC DISCONNECT AWG#10 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I., 451C 0.95 25 FT O.G% tV 11 3 AC DISCONNECT MAIN PANEL AWG#G 1 3 I THWN-2 AWG#8 1 THWN-2 CU PVC I.. 459C 0.95 10 FT O.G% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acit Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED POR GOO V AND 90QC WET ENVIRONMENT. [NEC G90.8(B)(I)]: (Isc)'(#of5trin s)'(1.5G) = 1 9.GG A 3-LINE DIA. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 9 Modules per String 1 3 TO, AND LOCATED AS CL05E AS P05-915LE TO THE NEAREST RIDGE,HIP, OR VALLEY. AWG#12,amp.GG A Temp oreDerD = e I G A 20.I G A> 19.GG A,therefore DC wire size Is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 2G COMPLY WITH NEC 1 10.26. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 39.33 A Record low temp -I OQC FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE550RIE5 TO FULFILL AWG#8, ampacity'(Temp Derate)'(Condult Fill De-rate) = 52.25 A Voc Temp Coefficient -0.24%/QC DRAWING SCALE APPLICABLE CODES AND STANDARDS. 52.25 A> 39.33 A, therefore AC wire size Is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, Operatinq Current 10.8 A N .T.5. THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. Operatinel Voltacle 37.1 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Max. System Voltage 49.G V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 13.9 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR ILSCO G15L-4DBT LAY-IN LUG. Max AC Output Current 39.33 A 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) PV-5 OR O eratin AC Volta e 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000-107-2-9.2 Zoho Sign Document ID:2A768FFA-RUKHYDKYCARY190GZWSPCYOZ7YWN7XWGZ8EOTL3BEUO SERVICE METER O O DESIGN 4 DRAFTING DY: 1 N STALLAT I O N NOTE ELEMENT ENERGY LLC SOLAR PV SYSTEM PHOTOVOLTAIC • • • ( 1 ) ALL LABEL SHALL BE INSTALLED IN REVIEW BY J.M.NABCEPCERTIFIE • . 05112-129 EQUIPPED WITH ! SOLARBREAKER l • ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® •• • REQUIREMENTS. REvisioNs DERI 5CFrl0N DATE REV •. •' (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 05-01.2023 — MAX SYSTEM VOLTAGE SOLAR AC LOAD CENTER- OUTSIDE DO NOT RELOCATE THIS: I SHORTREQUIRE FIELD VERIFICATION. g OVERCURR_EN_T_DEVICE I (3) LABELS, WARNING(5) AND MARKING OO TURN RAPID SHUTDOWN SWITCH To Og SHALL BE IN ACCORDANCE WITH NEC THE'OFF POSITION TO SHUT DOWN _ 1 10.2I (B). I PV SYSTEM AND REDUCE : CAUTION SHOCK HAZARD IN THE ARRAY AC DISCONNECTUOYMCSOU (4) THE MATERIAL USED FOR MARKING voweR To nas svry a use swvu n SOLAR AC LOAD CENTER- INSIDE 2 J MUST BE WEATHER RESISTANT, IN COMPLIANCE WITH NEC 110.2 I (15)(3). CONTRACTOR NTNG i (5) THE PV SYSTEM CIRCUIT CONDUCTORS ® O7 ® I I ® ' ± W 1NG �YFL SHALL BE LABELED INSTALLED IN ELEMENT ENERGY, LLC. THIS EQUIPMENT FED BY MULTIPLE DUAL POWER SUPPLY 7470 SOUND AVE SOURCES.70TAL RATING OF ALL COMPLIANCE WITH NEC 690.3 1 . OVERCURRENT DEVICES,EXCLUDING SOURCES:UTILITY GRID MATTITUCK, NY 1 195 MAIN SUPPLY OVERCURRENT AND PV SOLAR LICENSE # G74G 1-111 DEVICE,SHALL NOT EXCEED ELECTRIC SYSTEM LICENSE # 52G89-ME CONDUIT - INSIDE 13UILDING AMPACITYOFBUSBAR. - O ! WARNIN © - - - 7D. l N G I THIS IS SERV C EM s� PROJECT NAME ELECTRIC SHOCK HAZARD TAIC SYSTEM PHOTOVOLTAIC SYSTEM TERMINALS ON THE LINEAND ER PANEL _LOAD SIDES MAY BE ENERGIZED DD LOADS CONDUIT - OUTSIDE BUILDING —IN THE OPEN POSITION - - L--1 W N ® z z m • • • LU U-J Q T! W RNING � .'• • ' � �. DUAL POWER SUPPLY ® L1...1 Q z SOURCES:UTILITY GRID AND E z P SCLAR ELECTRIC SYSTEM' _ O MAIN SERVICE PANEL - OUTSIDE A CAUTION SOLAR CIRCUIT _.ACAUTION _ CL/ OO SOLAR ELECTRIC SYSTEM CONNECTED wmQ MAIN SERVICE PANEL - INSIDEI W RNING OPERATING OPERATING I POWER SOURCE I OUTPUT CONNECTION ��I I N f DO NOT RELOCATE THIS E(/v f SHEET NAME ® O OVERCUR RENT DEVICE_ �,�P�_Q0 A LABELS AC DISCONNECT/BREAKER �O Z03443 DRAWING SCALE IO OO OO ® Ago sslN .T.S. 5NEET NUMBER PV-G TAX MAP: 1000-107-2-9.2 Z ` 0 RON R0 DGE Fl ush Mount System •by _ - ,YY Built for solar's toughest roofs, IronRidge builds the strongest mounting system for pitched roofs in solar. (Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashin s a is also why our products are fully certified, code compliant and backed by a 20-year warranty. g nd Strength Tested PE Certified All components evaluated for superior' structural performance. Pre-stamped engineering letters available in most states. Class A Fore Rating Design AssistantCertified to maintain the fire resistance rating of the existing roof. MES Online software makes it simple to create, share, and price projects. ADL 2703 Listed Systema 20mYeao•Warranty Entire system and components meet newest effective UL 2703 standard. Twice the protection offered by � competitors. / R Rail's � XR10 Rail | se internal splices A low-profile mounting rail The ! / rail for commercial projects. for seamless connections. ^ S'opanningcapabUuy . 12'spanning capability Self-drilling screws ^ Moderate load capability A heavyweight mounting Ail rails u for regions with light snow. solar - Extreme load capability Varying versions for rails he Hea ^ Clearandblaokfinish - Clear anodized finish Forms secure bonding Clamps G/OUndingUFOs �� ultimate " Stopper Sleeves Grounding Lugs Micrminvertr � Kit* ' i4� .34 ft , . M oun_ ' K |aorPOs 10 XR Universal Fastening Objects Snap onto the bond oduleotor�\a' \n� abondadonddamp. equipment ground. ��. , Fully assembled& |ubed Bonds modules 1orails ~ Low profile ~ Bonds devices torails ~ Single, universal size Sized to match modules ~ 3ingie1ooi installation ~ Kit comes assembled ^ Clear and black finish Clear and black finish ` Mounts in any direction ^ Listed toUL2703 -- Attachments �� --------� _ Bonding Hardware Conduit Mount «*xou�^,�-"�=° FgamhFoo�� �RH�8 �� -�-- ' - toroofodaohnnen1m r/u*'/ �..° '''""''^ - Bond an attach XR Rails attachment. ory�njunction _ mx� � .^,^, ___ vvunoupenu` �uu�p'"""'`� --` ^ S�cure ��| nonn�otNno T&Square Bo �op1�n m ~ Tw�t-o» Cap�uo��^" ~' ^ Tw�t�mCap eases install eo7/1S"socket ^ Wind-driven rain tested ~ Wind-driven rain tested ~ Slot for Nut us ` Mill and black finish ~ Secures 3/4'nr1"conduit ^ Clear and black finish Assembled and lubricated ed Resources NABCEP Certified Training Design Assistant Earn free continuing education credits, Go from rough layout to fully AP "D e while learning more about our systems engineered system. For fre Go to lrorR�dge,com/tr3injng Go to lronRidge,corn/design __J ENPHA►SE. IQ8 and IQ8+ Microinverters Easy toinsta8 Our newest 108 Microinverters are the industry's first microgrid-forming,software- - Lightweight and compact with defined microinverte►s with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter . power line Communication. is our proprietary application-specific integrated circuit(ASIC)which enables the Powe UneC ro components microinverter to operate in grid tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times - Easter installation with simple to changing loads and grid events,alleviating constraints on battery stung for home ^+�iec�tiRg energy systems. Haigh producWtg and reliability produce power even when the ,x _ Enphasegrid is down" More than one million cumulative hours of testing I -�.- _-- - Class 0 double-insulated Part of the Enphase Energy System,108 Series I08 Series Microinverters redefine relfability enclosure Microinverters integrate with the Enphase IQ Battery. standards with more than ane million cumulative - Cqr imiwd foe the latest high— Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- powered PV modules and analysis software. leading limited warranty of up to 25 years. p UlcroWld-fO1i111119 - Comptes with the latest advanced grid support" CERTIFIED - Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily to IQ8 Series I08 Series Mlcroinverters are UL Listed as - Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. • Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other `Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. "I08 and IQ813Ius supports split phase,240V I08SP-DS-0002-01-EN-US-2022-03-17 installations only. i IQ8 and IQ8+ Microinverters INPUT DATA(DC1 ,• ,.. Commonly used module pairings' w 235-350 235-440 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 Module compatibility 60-cell/120 half-cell half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 36/48 30/58 Max input DC voltage V 50 60 Max DC currentz(module Isc] A 15 Overvoltage class DC port If DC port backfeed current MA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT D. 108-60-2-US IOSPLUS-72-2-US Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20.A(L-L)branch circuit 16 13 Total harmonic distortion <5% Overvcltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -400C to+60OC'(-40OF to-04000 Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741AEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C222 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690]2 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 108SP-DS-0002-01-EN-US-2022-03-17 powered by ® ®. YR 1, ot 'i-TOP BAND PV. cuaovE ? Warr ar►ty 2®2$f p CELLS prod.s3PeYield Security a_ BREAKING THE 20%EFFICIENCY BARRIER nn/II Illlnllll�IIS Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new`Quality Controlled PV"of v� the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY �?z Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QTm. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year 1 linear performance warranty2. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) ]See data sheet on rear for further information. THE IDEAL SOLUTION FOR: C9Rooftop arrays residential buildings Engineered in Germany uCELLS I MECHANICAL SPECIFICATION Format 74.0inx41.linx1.26in(including frame) _ (1879 mm x 1045 mm x 32 mm) 74.0'(1069 mm) t39ss ten) 42.a•(l0e8mm) N/eight 48.5lbs(22.Okg) =rant Cc'6=r 0.13 in(3.2 mm)thermally pre-stressed glass with =�s(125omm) anti-reflection technology 4„on„ndne Wlma901E'(a5mn) Rana Back Caner Composite film 382'(996mm) Frame Black anodized aluminum Cell 6 x 22 monocrystalline Q.ANTUM solar half cells � all uo4smm) Junction Sax 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes � =�2(12SOmm) Cable 4mm2 Solar cable;(+)249.21n(1250mm),(-)2_49.2in(1250mm) a„D�na9nnan 4„10wnvn951-(DETALA) Connector Staubli MC4;IP68 j 128'(32 mm) DETAILA 0.83.116 mm) -� 0.96'(24.5mm)I-OI0.33'185mm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 �,ltlilAtlUP 1?'ERFCRl i 1iVCE:1T aT 1i1lC.AN0 7:GT COIN01711.MS,5T01(POINER TOLERAiAlCF+51N!-01)11; _ PcrleratNIPP1 PMpp [W] 385 390 395 400 405 Shrrt Circuit Cturnt' Isc [A] 11.04 11.07 11.10 11.14 11.17 E oven circuit Voltage ^� Voc [V] 45.19 45.23 45.27 45.30 45.34 '£ Current at"A Pp IMpp [A] 10.59 10.65 10.71 10.77 10.83 Voltage at ArlPP VMpp [V] 36.36 36.62 36.88 . 3 7.13 3239 Efficiency' 1`1 [%] r 2-19.6 2_19.9 2_20.1 2-20.4 2_20.6 dMINUVUNI?ERFORMANCE A7 NO,A:IAL OPERATING C'ONC)TIONS,i1i"ICT, - Povigratlylpp PMPP--� (W] �~ 288.8 -^ 292.6 296.3 300.1 303.8 E Shaft Ci;cult Curren, sc [A] 8.90 8.92 8.95 8.97 9.00 00-2n Circuit Voltage Voc [V] 42.62 42.65 42.69 42.72 42.76 C u"an't a-IMpP IMpP [A] 8.35 8.41 - 8.46 8.51 8.57 Voltega al:MPP - --- VMPP-- [V] 34.59 34.81 35.03- 35.25 35.46 =Measurement tolerances PMpp±3%;Isc;Vcc±5%at STC:1000W/ml,25±2'C,AM 1.5 according to IEC 60904-3.2800 W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE u z 00 -ata . At least 98%of nominal power during -`iso first year.Thereafter max.0.5% S2 j „_____ degradation per year.At least 93.5% ------------ of ___________of nominal power up to 10 years.At F least 86%of nominal power up to a I I I J -- -- 25 years. 2 i i 1 I i I o All data within measurement tolerant- 1 ®-------------------___----- 60 as.Full warranties in accordance with mo 460 ea6 eoo loco 0 a the warranty terms of the Q CELLS IRRADIAM-svtm=t sales organisation of your respective o p „ 6 country. n,ay�wee ro,n.:9wwmmea Y-A!9s Typical module performance under low irradiance conditions in a wlu Ve 15�Pau]bnc�eniv F 2Pa;v Q SrylmLur F.e) 2 comparison to STC conditions(25'C,1000 W/m) TEMPERATURE COEFFICIENTS 0 Tsmparature Coefficient of Isc e [%/K] +0.04 Tampara':u7s Ceefficieri of VDc p [%/K] -0.27 21 Temperature Coefficient of P,,pp y [%/K] -0.34 Nominal dtlodule Operating Temperature NMOT [°F] 109±5.4(43±3°C) m 0 PROPERTIES.FOR SYSTEM DESIGN a w Maximum System Voltage V's [V] 1000(IEC)/1000(UL) PV module classification Class II 0 N tilaximum Serias=use Rating [A DC] 20 Fire Rating basad on ANSI!UL 51730 TYPE 2 W Max.Design Load,Push/Pull' [Ibs/ft2] 75(3600 Pa)/55(2660 Pa) Permitted iModulaTemparaturs -40'Fupto+185°F p Max.Test Load,Push/Pull' [lbs/ft'] 113(5400 Pa)/84(4000 Pa) on Continuous Duty (-40'Cupto+85°C) e m m 'See Installation Manual m U V QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m ,Q, o UL 61730,CE-compliant, n Quality Controlled PV-TOV Rheinland, I A e IEC 8atent o.9,8C,215(s(solar SP® ♦ / D U.S.Patent No.9,893,215(solar cells), v (` C TwR�nl� Horizontal 76.4in 43.3in 48.O in 16561bs 24 24 32 .. OCPV Certification ongoing. C US packaging 1940mm 1100mm 1220mm 751 kg pallets pallets modules 1. UL 61730 ID 11112302TJ 6 V) Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha G;CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 96 1 EMAIL inquiryQus.q-cells.com I WEB www.q-cells.us