Loading...
HomeMy WebLinkAbout48797-Z Town of Southold 1/29/2024 P.O.Box 1179 C4 _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44639 Date: 10/4/2023 THIS CERTIFIES that.the building SOLAR PANEL Location of Property: 1105 Dean Dr, Cutchogue SCTM#: 473889 Sec/Block/Lot: 116.-5-1.4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/22/2022 pursuant to which Building Permit No. 48797 dated 1/25/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing seasonal single family dwelling as applied for. 1/29/2024 Corrected to say seasonal dwelling only. The certificate is issued to Zimmer,John&Suter-Zimmer,Anne of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48797 7/24/2023 PLUMBERS CERTIFICATION DATED �) �\ n Au or ed i ature �S11FfOl,�oG Town of Southold 10/4/2023 0 a y� P.O.Box 1179 H x 53095 Main Rd 41 Way o� } Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44639 Date: 10/4/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1105 Dean Dr, Cutchogue SCTM#: 473889 Sec/Block/Lot: 116.-5-1.4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/22/2022 pursuant to which Building Permit No. 48797 dated 1/25/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar.panels to existing single family dwelling as applied for. The certificate is issued to Zimmer,John&Suter-Zimmer,Anne of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48797 7/24/2023 PLUMBERS CERTIFICATION DATED i th ri ed ignature 0 J SUFFn TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48797 Date: 1/25/2023 Permission is hereby granted to: Zimmer, John 10518 Rosehaven St Apt 205 Fairfax, VA 220302855 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled and readily accessible. At premises located at: 1105 Dean Dr, Cutchogue SCTM #473889 Sec/Block/Lot# 116.-5-1.4 Pursuant to application dated 12/22/2022 and approved by the Building Inspector. To expire on 7/26/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector oF so�ryQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q ,�► • �o sean.devlinCcD-town.southold.ny.us Southold,NY 11971-0959 Q 01�OW N,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: John Zimmer Address: 1105 Dean Dr city:Cutchogue st: NY zip: 11935 Building Permit#: 48797 & 48798 Section: 116 Block: 5 Lot: 1.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: GreenLogic LLC License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect F1 Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 9.96kW Roof Mounted PV Solar Energy System w/ (24) SPRM415W Modules, SunPower Monitor, 60A AC Disconnect, Combiner Panel Notes: Solar on House & Detached Garage Inspector Signature: f� Date: July 24, 2023 - :e - S. Devlin-Cert Electrical Compliance Form.xls souryol o * # TOWN OF SOUTHOLD BUILDIN DEPT. `Mouff", 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C^/O [ ]' RENTAL REMARKS: a l DATE INSPECTOR OE SOUlyO6 L-L b-7 1 ��- # # TOWN OF SOUTHOLD BUILDING DEPT. couto, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 4 < �� -c4 r C DATE `� INSPECTOR s 0 TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 . INSPECTION FOUNDATION I ST ROUGH PL13G. FOUNDATION 2ND ],ASULATION/ LKING FRAMING /STRAPPING FINALCn( FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) CODE VIOLATION PRE C/O RENTAL REMARKS: DATE 10M W)"� INSPECTOR suiFoi,r o`A ' coG TOWN OF SOUTHOLD—BUILDING DEPARTMENT ti x Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Woy • Telephone(631) 765-1802 Fax(631) 765-9502 httr)s://www.southoldtownn ov v Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only E C F � VE PERMIT NO. Building Inspector: D DEC 2 2 2022 Applications and forms must be filled out In thelr,entlretyalncorriplete appP'cations will not be accepted Where;the Applicant is not the owner,an BUILDING DEPT.•. Ovuner`s Authorization form(Page 2)shall be completed TOMOFSOIdifIOLD 4 Date: ( Z 20 2022. 01'tVNER�S}OF PROPERTY Name:,John Zimmer � j �L. scrM#s000- - ProjectAddress:1105 Dean.Drive Cutchogue NY 11935 Phone#:703-963-3780 _.-..- .. ...._ .-. _ .. _ .-- Email:asuterzimmer@gmail.com Mailing Address:Pp Box 1107_Cutchogue NY 11935 CONTACT PERSON Name:Barbara - GreenLogic LLC Mailing Address:97 North Sea Road, Southampton,%NY _11968 Phone#:631-771-5152 x117 7Email:Barbara@Greenlogic.com DESIGN PROFESSIONALINFORMATION Name: Mailing Address:Z C �.� Phone#: 1P_�J.�. ��J gam......... �..$g... - rEmail: - h �YYk�55C�arO�•- CONTRACTOR.INFORMATION k Name:GreenLogic LLC. „ - Mailing`Address:-97 North Sea Road, Southampton,_NY 11968 Phone#:631-771-5152 ,E"_'ai':AM@Greenlogic.com DESCRIPTiION OF PROPQSED CONSTRUCTION »`4 El New Structure ❑Addition Alteration ❑Repair ❑Demolition Estimated Cost ofProject: ❑• 4 Other Solar Panels $ L 0 00 houne'±qg Will the lot be re-graded? ❑Yes 2N Will excess fill be removed from premises? ❑Yes ENO 1 PROPERTY INFORNIATION� ,f, Existing use of propertyq ,4M vy 1i ,vt .4f ..Intended-use—o,f property.: Zone or use district in which premises is situated: Are there any covenZnts and restrictions with respect to this property? E]YesKNo IF YES, PROVIDE A COPY. C7 yCheck°Box After Readl ng The owner/contractor/design professional is responsible for all drtriage and stone r,water issues'as-0&vide&4j--- ,uii Chapter 230pf# wn - - — HEREBY to th6:8ui!0i0g2o"eordinance ofthe Town of Southold, ,,_ other jj -a Suffolk,C d additions, %�Ti,o ordinances,building hou ,qreM'valor er i 'g`code Shd.!egulatlons�andi in # jns09!qo!s qqpij�njisc��qtjj--,built :6.'ai:lli6kjiuihd-k6 dj` lin 6 iessa rndhts made,herein are. ishable agi&misdemeanorpursua na I as a .._- " 1 .1 11. - W.- ybr,Stite-Pi Application Submitted By(print name):GreenLogic LLC MAuthorized Agent ElOwner ... . ....... Signature of Applicant: jUtAA,,%,j1 Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ee 'I- day of A40-rL�---,20 P-1- Notary Public BARBARA A CASCIOTTA Public-State of N PROPERTY OWNER AUTHORIZATION NotaryNo.01-CA4894969 York (Where the applicant is not the owner) Qualified in Suffolk County Commission Expires May 11,202 1 110 5 JRX-4M DM-N C—: -bPA Mf!17-` _residing at W OJE 01 My do hereby authorize GreenLogic LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Sigure Date A,4)ae istymp ;h&Wnp- Print Owner's Name 2 1 . BUILDING DEPARTMENT- Electrical Inspector b ��G TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road- PO Box 1179 P" Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 � t rogerr southoldtownny.gov -- seand(ci)southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 12/20/2022 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: BarbaraCGreenlogic.com Phone No: 631-771-5152 ❑✓ I request an email copy of Certificate of Compliance Address.: , 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: John &Anne Zimmer Address: 1105 Dean Drive, Cutchogue, NY 11935 Cross Street: Phone No.: 703-963-3780 Bldg.Permit#: email: asuterzimmer@gmail.com Tax Map District: 1000 Section: 116 Block: 5 Lot: 1.4 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (24) SunPower SPR-M415-H-AC panels Et (24) Enphase IQ7HS micro inverters 21 (1) SunPower PVS6 monitor System Size: 9 960KW (6) panels on garage Check All That Apply:I (18) panels' on main house . Is job ready for inspection?: [—]YES ❑✓ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: ❑✓ YES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service 11 'Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑l ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx Aco CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) t% . F0210112022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Nicholas Zulkofske Brookhaven Agency,Inc. PHONE 631 941-4113 FAX 631 941-4405 100 Oakland Ave,Ste 1 E-MeuL Certificates@ brookhavena enc .corn Port Jefferson,NY 11777 INSURERS AFFORDING COVERAGE NAIC N INSURER A: Southwest Marine&General Insurance Co. INSURED INSURER B: Merchants Preferred Insurance Co. GreenLogic,LLC INSURER c: First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D: National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E: AGCS Marine Insurance Co. INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER MMU CY EFF POLLTRICY EXP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A CLAIMS-MADE X�OCCUR DAMAGE TO RENTED $100,000 X Contractual Liability X X GL202200012922 01/31/2022 01/31/2023 MED EXP(Any oneperson) $5,000 PERSONAL 8 ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE s2,000,000 POLICY F JECT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: I E&O Liability $1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1,000,000 B X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08/11/2021 08/11/2022 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY X AUTOS ONLY $ UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS UAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION $ WORKERS COMPENSATION PER OT H- EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVEE.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? F—] N/A see separate certificate (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ C NYS Disability D251202 04/11/2021 04/11/2022 Statutory Limits E Installation Floater/Property SML93076366 04/15/2021 04/15/2022 $300,000 $2,500 Ded DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may he attached if more space is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD "Nv: H �1/ 4 NY: K' T VIQ �11� vt v. NY4Ft= E .: •., .? '' ':�'v! illv "Ofte:`41 &I Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 DATE ISSUED: 5/25/2006 No. 40227-H U lei SUFFOLK COUNTY .......... Home Improvement Contractor License This is to certifv that MARC A CLEJAN doing business as GREEN LOGIC LLC having furnished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules olk,State of New York is hereby licensed to conduct business as a HOME and regulations of the County of Suff IMPROVEMENT CONTRACTOR,in the County of Suffolk. ,.I,-d` Additional Businesses NOT VALID WITHOUT D)EPARTMENTAL SEAL AND A CURRENT CONSUMER AFFAIRS ID CARD V. V 0, Director J.. Workers' YORK CERTIFICATE OF STATE Com Boar ensati®n NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Greenlogic LLC 631-771-5152 97 North Sea Rd,Suite 3 South Hampton,NY 11968 1c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) United Wisconsin Insurance Company Town of Southold Building Department 3b.Policy Number of Entity Listed in Box"1 a" 53095 Route 25 WC605-00090-022-SZ Southold,NY 11971 3c.Policy effective period 10/15/2022 to 1/1/2023 3d.The Proprietor,Partners or Executive Officers are included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3 on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that 1 am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Alicia Christiansen (Print name of authorized representative or licensed agent of insurance carrier) Approved by: ,e9E C (Signature) (Date) Title: Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 941-306-3077 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov YORK Workers' CERTIFICATE OF STATE Com pensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Greenlogic LLC (631)771-5152 97 North Sea Rd 1 c.NYS Unemployment Insurance Employer Registration Number of Suite 3 Insured South Hampton,NY 11968 Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) United Wisconsin Insurance Company 3b.Policy Number of Entity Listed in Box"l a" TOWN OF SOUTHOLD WC605-00090-023-SZ BUILDING DEPARTMENT 53095 ROUTE 25 3c.Policy effective period SOUTHOLD,NY 11971 01/01/2023 to 01/01/2024 3d.The Proprietor,Partners or Executive Officers are ❑ included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box 1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Alicia Christiansen (Print name of authorized representative or licensed agent of insurance carrier) Approved by: ,�Q �� / DZ� (Signature) (Date) Title: Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 941-306-3077 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov LOGIC® 'J1mtGR EEN ENERGY December 20, 2022 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: John &Anne Zimmer 1105 Dean Drive Cutchogue, NY 1000-116-5-1.4 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) ' Please let us know if you need anything else in connection with this application. Yours truly, J'3aJmac&oc&ua Barbara Casciotta Account Manager Barbara@Greenlogic.com GREEN62jigAC5lg2,6�fecin}lgic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S. Service Rd., #106 Southampton, NY 11968 Rosyln Heights, NY 11577 t ' ' 4 ' S �. ?'.. .. .. .. ....r..... ` .. , 'ii. .. .. .aPi .. .. :. .�. ...: ...... r.•-wa:-ori.-.r-- _ {j INTEN STA C. T .. ... -'. PL It �:S.EI(1f•AGE r } .. ...... :•':- ,1.. .. -. ..-•..v .. .. ,i, n..rr•.1•+-.+rarY+•..r. .S ... ...:.Y.'. .'4. ';•.:,'.:.-N-'F.,�.."''... i. ✓t .r /•�{ .. :. . ... . .... ... .::.... .. .... .'......:... .... ,....Sr: � _ . .THE: S. ,- .. s.. `` . ... . . . ., 'a.-:,.... .; ,- ... �.......... .... ......... .: .. .. ..... . ... ...... ... . DIEpT. -A L14 5E... , :S .. ....... . .. .. .. - r" r STt2UC:�1ON. k :.. M. _ . :' ..'. • .. ..:. .. . ..... ... .. .. . .. . .. ..•. ,'i- � _ TAX-'MAP.DF_-,SIGN'A'[`tCTi`�3.=��^- .._ -... .. .. - .. ... .. ...... . ........ ... .. .. : . .:.. ...._....,.- ....... � . •, � �. � ECT:.' ���:. _BLOCK. S U Llf: c .. .. .-. .. Jr .. ... :. . � .. ...,......:....:.::... .. . . ::..• ,al. ��; DRESS• . ,�• owN:ERs AD MM s l a- 1 I:. '1 �` t .k •C..• NUR1L�>+Lt� ,. .: •`�:!'••r UF.iH� iiK'W:YGotc St�:�@'::. �pl,�ATiC>N LAW.'. 4 k`l :3 L.t J -C 56 I v.. s .Y' t.G. I , .. .-' _ �.y::'�".. _.. - bp,.-�`�3d."L.Jc.-,.:-,5••."T ins!" :y It 9. . i 5 VYY^. a .d ( =w a• fci• t w , :..' �'" :Id .. �•� 0.L S� .(.,�.S:S{ , v � i k� r 1 - T a. f 1 7 F . . tT Y i AN ,. . . . .. . . ... .. . .. .... 4� ROVER ICK'V.... r ....:....-. ENSEt?=1::f1'i�D'SUR �YOR. ..,. ... . .... . . . i APPROVED AS NOTED OCCUPANCY OR USE IS UNLAWFULDATE• 'c7S' B.P.# X87 WITHOUT E FEE��-P BY: CERTIFICATE NOTIFY BUILDING DEPARTMENT AT OF OCCUPANCY 631-765-1802 SAM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST 4w�tF'L`i WI' 'H ASL CODES OF BE TE FORGO. I•JTEW YORK STATE & TOWN CODES ALL CONSTRUCTION SHALL MEET THE AS REQUIRED AND CONDITIONS OF REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR SOUTHOLD TOWN ZBA DESIGN OR OONSTRUCTON ERRORS - SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES iJ.Y.3.DEC ELWMC uL DOMMM REQUIRM RETAIN STORK WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. J A M E S J. S TOUT A R C H I T E C T & Assoc. 2 G REG L ANE E AST NORTHP0RTN. Y. 891 - 8 58 9988 Letter of Certification December 12,2022 RE: Zimmer Residence 1105 Dean Drive Cutchogue, NY 11935 To whom it may concern: I,James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above listed address and have determined the structure and the attachment to be adequate to support the new additional load imposed by the proposed solar system and complies with the 140-mph wind design load as per 2020 Residential code of NYS (RCNYS),2020 Energy conservation construction code of NYS(ECCCNYS),and the ASCE 7-16. The existing 2"x 10"@ 16"o.c roof rafters and the existing 2"x 8"@ 16"o.c roof rafters will provide the required support.The existing roof has 1 layer of shingles on 15#building paper on W"plywood sheathing. James J.Stout Architect �%ED 'QAC � Oa 2 33 yOQ i NES GneenL.ogic,LLC Approved Zimmer,Anne 1105 Dean Drive Cutchogue NY,11935 Surface#A: Total System Size:9.960kVV Array Size:4.980kW 1 circuit of 6 on a 20A breaker 1 dreuk of 6 on a 20A breaker Azimuth:180° Pdch:34° Monitoring System: N SunPower Pand/Array Specifications: Panel:SPR-M415-BLK-H-AC . Racking:SunPower Invisimount ® Panel:73.7"X 40.6" Array:34'4 We X 12'41/8" Surface:51'11"X 32'10" M is#:Invisimount Legend: EM 12 SunPower 415W Panels SunPower Invisimount Rail 24 Iron Ridge Flash Foot 2 8 2x10"Douglas Fir Rafter 16'O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iran Ridge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: CPEO ARC 16 NEM, Drawn By:DF wing#1 of 14 Date:12/07/2022 REV.A Drawing Scale:1/&'=I V i- l 'LOGIC° GmenLogfc,LLC Approved Zimmer,Anne 1105 Dean Drive Cutchogue NY,11935 Surface#A: Total System Size:9.960kW Array Size:4-980WV 1 dreuit of 6 on a 20A breaker 1 dicuit of 6 on a 20A breaker Azimuth:180" Pitch:34" N Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7'X 40.6" Array:34'4 314°X 12'41/8" Surface:51'11"X 32'10" Ma is#:Invisimount L end: ED 12 SunPower415W Panels SunPower Invisimount Rail 24 Iron Ridge Flash Foot 2 18 2x10"Douglas Fir Rafter 16'0.C- Notes: 6"O.C.Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect.Seal: ED ARC :S Draw By.D Drawing#2 of 14 _ - Date:12/0720 REV:A Drawing Scale:116'=1.9 LOG ICS' &ee woc,LLC/V proved Zimmer,Anne 1105 Dean Drive Cutchogue NY,11935 Surface#A: Total System Size:9.960kW Array Sia:4.980kW 1 circuit of 6 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth:180" Pitch:34° Monitoring System: N SunPower Pand/Array 3 ifications: Panel:SPR-M415-BLK4i-AC 1 2 Racking:SunPower Invisanount ® Panel:73.7"X 40.6"34' Array: 4 3/4"X 12'411W Surface:51'11"X 32'10" Ma is#:Invisirnount Legend: 1Y ED 2 12 SunPower415W Panels NVV SunPawer Invisimount Rail 24 Iran Ridge Flash Foot 2 I 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iran Ridge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ,pkED ARC ). ,S w Q � : ; _ NES Drawn By:DF Drawing#3 of 14 Date:12/07/2022 1 REV:A Drawing Scale:1/8"=1.0' 4A t,. iLOGIC" C,reenLoyc,LLC/approved Zimmer,Anne 1105 Dean Drive Cutchogue W,11935 Surface#B: Total System Size:9.960kW May Size:0.830kW 1 circud of 2 on a 20A breaker Azimuth:90° Pitch:34* Monitoring System: SunPower Pand/Array Specifications. Panel:SPR-M415-BLK4H-AC Racking:SunPower Invisimount Panel:73.T X 40.6" Array:6'10'X V 13/4" Surface:25'5°X 15'9' Ma is#:Invisimount Legend: [[[J 2 SunPower 415W Panels -� SunPower Invisimount Rail • 61ron Ridge Flash Foot 2 8 2x8"Douglas Fir Rafter 16°O.C. Notes: Number of Roof Lags:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: BRED ARC _ NEIN Drawn By D swing#4 of 14 Date:12/07/202 REV:A Drawing Scale:1/4"=1.0' i »• ' .. 1.u. �'.R ..LOGIC GrsenLogrc,LLC Approved Zimmer,Anne 1105 Dean Drive Cutchogue NY,11935 Surface#B: Total System Size:9.960kW Array Sae:0.830kW 1 circuit of 2 on a 20A breaker Azimuth:90° Poch:34° Montoring System: SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6° Array:6'10°X V 1314! Surface:25'5"X 15'9" Ma iC#:Invisimount Legend. 2 SunPower 415W Panels — SunPower Invisinount Rail • 6 Iron Ridge Flash Foot 2 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iran Ridge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ���ED ARCM �5 �5 ]• ;ST -, Q � y . J►�, 21 COQ _ E`N Drawn By.DF D,kwIng#5 of 14 Date:12/07/2022 FREV.A Drawing Scale:1W=1.0' r.. t. �^f; -LOGIC° GneenLogic,LLC Approved Zimmer,Anne 1105 Dean Drive Cutchogue NY,11935 Surface#B: Total System Size:9.960kW Array Size:0.83014W 1 circuit of 2 on a 20A breaker Azimuth:90° Pitch: Monitorinrin g System: SunPower Pand/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7°X 40.6" Array:6'10"X 6'1314° Surface:25'5"X 15'9" M is#:Invisimount Legend: 2 ( ] 2 SunPower 415W Panels �— SunPower Invisimount Rail 6 Iron Ridge Flash Foot 2 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ED ARCM Ss �<C1 _...r 41 Q . n�A �r a O Drawn By:DF Drawing#6 of 14 Date:12/07/2022 1 REV:A Drawing Scale:114"=1.0' -N LOGIC GreenLogic,LLC Approved Zimmer,Anne 1105 Dean Drive Cutchogue NY,11935 Surface#C: Total System Size:9.960kW Array Siae:1.660kW 1 circuit of 4 on a 20A breaker Azimuth:270° Pitch:34* _ Monitorinrin g System: SunPower Panel/Array S ificadons: Panel:SPR-M415-BLK-H-AC Racking:SunPower.invisenount Panel:73.7°X 40.6° Array:10'3 318°X V 71/8" Surface:25'W X 15'9" M is#:Invisinount 4 SunPower415W Panels SunPower Invisinount Rail • 10 Iron Ridge Flash Foot 2 2x8"Douglas Fir Rafter 16'O.C. Notes- Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.31 psf En neer/Am itectSeal: �aEp AAC 6S � ST9%�� `* r F � Drawn By:D Drawing#7 of 14 Date:12/07/2022 I REV,A Drawing Scale:1/4!'=1.01 *� .. t LOG ICO "RFJV GreenLogic,LLC approved Zimmer,Anne 1105 Dean Drnre Cutchogue NY,11935 Surface#C: Total System Size:9.960kW Array Size:1.660kW 1 circuit of 4 on a 20A breaker Azimuth:270° Pitch:34* Monitorinrin g System: SunPower —15Wn—emrray Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisirwunt Panel:73.7"X 40.6" Array:10'3 3/8'X 9 71/8" Surface:25'6"X 15'9" Ma icM invisimount L nd: 0 4 SunPower 415W Panels SunPower Invisimount Rail 10 Iran Ridge Flash Foot 2 I I 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: SPED ARC 011 . F NES Drawn By:D Drawing#8 of 14 Date:12/07/2022 1 REV:A • Drawing Scale:1/4"=1.0' Oft fl.� 1..1'.NLOG ICO GreenLogfic,LLC Approved Zimmer,Anne 1105 Dean Drho Cutchogue W,11935 Surface#C: Total System Sine:9.960kW Array Size:1.660kW 1 circuit of 4 on a 20A breaker Azimuth:270° Pitch:34* A& Monitorinrin g System: SunPower panel/Array Specifications: Panel:SPR-M415-BLK4H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" 3 Array:10'3 3/8'X V 7118' Surface:25'&'X 15'9" Ma is#:Invisimount LOPM 4 SunPower 415W Panels SunPower Invisimount Rail 10 Iron Ridge Flash Foot 2 3 I I 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iran Ridge,SunPower Added Roof load of PV System:2.31 psf En neer/Amittect Seal: ARCy . tu i Drawn By:DF raving#9 of 14 Date:12/07/2022 1 REV:A Drawing Scale:114"=1.0' - NN LOGIC® GrewWc,LLC Approved Zimmer,Anne 1105 Dean Drive Cutc hogue W,11935 Surface#D: Total System Size:9.960WV Array Sime:2.490kW 1 circuit of 6 on a 20A breaker Azimuth:180° Pitch:15° N Monitoring System: SunPower Panel/Arra S Ifioadors: Panel:SPR-M415-BLK H-AC Racking:SunPower Invisimount Panel:73.7X 40.6" Array:l0'3 318'X 17 411W Surface:13'8"X 14'2" Magic# Invisimount Legend: ED end- ED 6 SunPower 415W Panels SunPower Invislmount Rall 0 12 Iran Ridge Flash Foot B 1 2x8'Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:iron Ridge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seat: SPED ARc� � 216 y0� Drawn By:DF Drawing#10 of 14 Date:12/07/2022 REV:A Drawing Scale:1W=1.0' { ..=_;. LOGIC® GreerrLogic,LLC Approved Zimmer,Anne 1105 Dean Drive Cutchogue NY,11935 Surface SIO: Total System Size:9.960k1N Array Size:2.490WV 1 circuit of 6 on a 20A breaker Azimuth:180' Pitch:15' Monitoring System: SunPower Pand/Affay Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:10'3 3/8"X 12'41/8' Surface:13'8"X 14'2" M is#.,Invisimount Legend: 6 SunPower 415W Panels —� SunPower Invisimount Rail • 12 Iron Ridge Flash Foot 2 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.31 psf En neer/Amt9tect Seal: �Rf-D ARC,g, 1 3 yOQ Drawn By:DF Drawing#11 of 14 Date:12107/2022 REV:A Drawing Scale:1/4"=1.0' LOG ICS GreenLogic,LLC Approved Zimmer,Anne 1105 Dean Drive Cutchogue NY,11935 Surface#D: Total System Size:9.960k N Array Size:ZOOM 1 circuit of 6 on a 20A breaker Azimuth:180° Pitch:15" N Monitoring System: SunPower Pand/Array S Icadons: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" 4 Array:10'3 318'X 12'41/8" Surface:13'8"X 14'2" Magic*Invisi aunt Legend: 6 SunPower 415W Panels SunPower lnvisimount Rail 12 Iran Ridge Flash Foot 2 A -E 2x8"Douglas Fir Rafter 16"O.C. Notes: 4 Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iran Ridge,SunPower Added Roof Toad of PV System:2.31psf 79 En near/Architect Seal: eED ARC g► 14J� \ CA �r `� 216 yoQ F �N Drawn By:DF rawing#12 of 14 Date:12M7/2022 I REV:A Drawing Scale:1/4"=1.0' No Vent Pipes Will Be Covered By The Solar Array =f`j = -, %LOGIC Legend: GmenLogfc,LLC Approved Zimmer,Anne AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 1105 Dean Drive per R202 definitions per R324.6.1 as per R324.6.2.1 Cutchogue NY,11935 Total System Sire:9.960kW 1 circuit of 6 on a 20A breaker 1 circuit of 6 on a 20A breaker 1 circuit of 6 on a 20A breaker I 1 circuit of 4 on a 20A breaker I i I I 1 circuit of 2 on a 20A broker AP I I Azimuth:180° L___I Monitoring System: iN SVnSunPower No Pand/Array Specifications: Panel:SPR-M415-BLK H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" F/ Magic#:Invisimount Legend: Un t7 Wer I I I 1 ® 24 SunPower 415VV Panels 6$ toI I I I — SunPower Invisimount Rail 415WIAPI IAPI 0 52 Iran Ridge Flash Foot 1 I I I I I 2x10"Douglas Fir Rafter 16"O.C. I I I I 2x8°Douglas Fir Rafter 16"O.C. I 1 1 I 4 SunPower —J `"————' `— 2 SunPower Number of Roof Layers:1 415W __svo _ _ svo__ 415W Height above Roof Surface:4" Materials Used:Iran Ridge,SunPower . S Added Roof load of PV System:2.31 psf En neer/Architect Seat: EAf,p ARc� 12 SunPower - 415W 0 yp� V� Drawn By:D Drawing#13 of 14 Meter Date:12!07/20 REV:A Drawing Scale:1/16"=I.V JOB MATERIAL LIST E` LOGIC® GreenLogic,LLC Approved Zimmer,Anne 1105 Dean Drive Cutchogue NY,11935 Tdal System Size:9-960kW Material List gtY Rail Material List Qty 1 circuit of 6 on a 20A breaker 1 circuit of 6 on a 20A breaker 1 circuit of 6 on a 20A breaker 1 circuit of 4 on a 20A breaker Cast Aluminum Mounting Block w/Blade Aluminum Flashing 52 1 circud of 2 on a 20A breaker 5/16"x1.25"Fender Washer 52 Azimuth:180° 5/16"x4.75"Hex-Head lag Screw 52 N Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7'X 40.6" Magic#:Invisenount L nd• ED 24 SunPower 415W Panels SunPower Invisimount Rail 52 Iron Ridge Flash Foot 2 8 I 200"Douglas Fir Rafter 16'O.C. 2x8"Douglas Fir Rafter 16'0.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: SPED ARC - 21 yOQ EVA Drawn By:D Drawing#14 of 14 Date:12/07/2022 REV:A Drawing Scale:1/16'=Iff d EQUIPMENT------__.—.-_--_ EXISTING SERVICE PV-SA-1 � A AC-COMBINER PANEL 120/240, 1 PH, 3W ' . . • r� AC-CMC-1 (PV LOADS ONLY) �� 200A KUVH j I f Z-f Ll ............_......._..............._......... PV-SA-2 -rA j • • o .. A B N � �C� - N2 1 � BKR-1 AC-DSC-1 � r� AC DISCONNECT i `1 i I PV-SA-3 BKR-2 f ! i -� I F 1 • • • I I � � • • o 1I I BKR-3 MAIN ( il FM Bt(R—h i A B N PV-SA-4 I /� i I FUSED ( . N IEGC N TYPICAL PV MODULE WITH IIII I I INTEGRAL DC/AC INVERTER ( III EGC I IIII I I � I EXISTING AC PANEILEXISTING I� IIII I __ __ ___ __ __ ( ' GEC I GEC LL! _®Lr_-�_ ___---6 cu � 9.960kW DC 9.216kW AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Zimmer, Anne 9 LOG ICO 1105 Dean Drive ~P` ,s Cutchogue, NY 11935 ENERGY '"3.y azi 3'��o�r ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION rF oF,t+e�t Page 1 of 3 Drawing No: Zimmer-3LD1 Revision: 1 Revised: 11/10/22 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-M-415-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 6-MODULES PV7SA-2 PV SUB-ARRAY SPR-M-415-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 6-MODULES I PV-SA-3 PV SUB-ARRAY SPR-M-415-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 6-MODULES PV-SA-4 PV SUB-ARRAY SPR-M-415-H-AC I ENPHASE IQ7HS, 1-CIRCUIT OF 6-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 2490 WATTS 211-264 VAC 10.13 A AC 240 V, AC PV-SA-2 2490 WATTS 211-264 VAC 10.13 A AC 240 V, AC PV-SA-3 2490 WATTS. 211-264 VAC 10.13 A AC 240 V,AC PV-SA-4 2490 WATTS 211-264 VAC 10.13 A AC 240 V, AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Zimmer, Anne ��5���7'sr"F':, LtGREENLOGICO 1105 Dean Drive �� '` _, �* ENERGY Y Cutchogue, NY 11935 ¢r ELIMINATING THE C"OST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION ATF baNE �° i Page 2 of 3 Drawing No: Zimmer-3LD1 Revision: 1 Revised: 11/10/22 ,,ON, r EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 25OV, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 100A, NEMA-1, FUSED; FUSE RATING: 100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 4 / 6 C THWN-2 2" EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE: GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Zimmer, Anne Q�`y^�� ' c��n�" �` GREENLOGICS 1105 Dean Drive ENERGY Cutchogue, NY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION �� .21 3-1 A0 ELIMINATING THE COST OF ENERGY • � � Page 3 of 3 Drawing No: Zimmer-3LD1 Revision: 1 Revised: 11/10/22 Y • M SUNPOWER®R 425-410 W Residential Black AC Module SunPower` Maxeon`Technology Built specifically for use with the SunPower EquinoxO system,the only fully integrated solution designed, engineered, and warranted by one company. Highest Power Density Available The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest-efficiency all-black AC solar module available.' .Part of-the SunPower Equinox`Solar System-. Seamless aesthetics I larger •Compatible with.mySunPower monitoring „ii;; , / Highest Lifetime Energy and Savings Designed to deliver 60% more energy over 25 ears in a��_�fi• - _.... g gY Y real-world conditions like partial shade and high temperatures.2 Factory-integrated' . . - Microinverter., "''" �� ..ti.7 Highest-power integrated ,.i,:. AC module in•-so lar `r' -1ef ' Conventional Panel •Engineered and calibrated. N n 1) :i -� by SunPower fo"r SunPower; ears of operation AC modules Best Reliability, Best Warranty With more than 42.6 million and 15 GW of modules deployed around the world, SunPower technology is proven to last.That's _. "' why we stand behind our module and microinverter with the industry's best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. Datasheet M425-BLK I M415-BLK M410-BLK SunPower Residential Black AC Module AC Electrical Data Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 Nom.(L-L)Voliage/Range'M 240/211-264 208/183-229 Max.Continuous Output Current(A) 1.60 1.77 Max.Units per 20 A(L-L)Branch Circult4 10 9 CEC Weighted Efficiency 97.0% 96.S% Nom.Frequency 60 Hz 60 Hz Extended Frequency Range 47-68 Hz 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A Overvoltage Class AC Port III III AC Port Backfeed Current 18 mA 18 mA Power Factor Setting 1.0 1.0 Power Factor(adjustable) 0.85(inductive)/0.85(capacitive) 0.85(inductive)/0.85(capacitive) DC Power Data Warranties,Certifications,and Compliance SPR-M425-BLK-H-AC SPR-M415-BLK-H-AC SPR-M410-BLK-H-AC Warranties 25-year limited power warranty Nom.Powere(Pnom)W 425 415 410 25 year limited product warranty Power Tolerance +5/-045 +5/-0% +5/-096 UL 1741/IEEE-1547 1_IIL 1741 AC Module I Module Efficiency 22.0% 21.5% 21.245 UL 61730(Type 2 fire rated) i Temp.Coef.(Power) -0.2946,•'•C -0.2996/'C -0.29%/'C UL 62109-1/IEC 62109-2 j --- ---- FCC Part i S Class B I Shade Tolerance Integrated module-level max.paver point tracking j ICES-0003 Class B i CAN/CSA-022.2 NO.107.1-01 j Go.Rule 21(UL 1741 SA)s + +' + + + + ! Certifications Volt/Var and Reactive Power Priority) UL Listed PV Rapid Shutdown Equipment' j Operating Temp. -40°Ft -185°F(-40°C to+85'C) and Compliance Max.Ambient Temp. 122°F(50°C) Enables installation in accordance with: j NEC 690.6(AC module) e wind:125 psf,6000 Pa.611 kg/m2 back I NEC 690.12 Rapid Shutdown Inside and outside the', Max.Test Load p ( i Snow:187 psf,9000 Pa,917 kg/m-front I array) Wind 75 psf,3600 Pa,367 kg/m=back j NEC 690.15 AC Connectors,690.33(A)-(E)(1) Max.Design Load j Snow:125 psf,5400 Pa,550 kg/m2 front When used with AC module Q Cables and accessories Impact Resistance 1 inch(25 mm)diameter hail at S2 mph(23 m/s) j (UL 6703 and UL 2238p Rated for:pad break disconnect PID Test 1000 V:IEC 62804Mechanical Data j Solar Cells 66 Maxeon Gen 6 Fronc Glass High-transmission tempered glass with anti-reflective coating Packaging + + • Environmental Rating Outdoor rated Modules per pallet 25 I Frame Class 1 back anodized(highest AAIvIA rating) Packaging box dimensions 75.4 x 42.2 x 48.0 in.(1915 x 1072 x 1220 mm) Weight 48 lbs(21.8 kg) I Pallet gross weight 1300 Ib(590 kg) Recommended Max. Pallets per container 32 Module Spacing 1.3 in.(33 mm) Net weight per container 18,880 k- 733 in ` FRAME PROFILE Based on datash?et review of websites of top 20 manufacturers per IMS,as ofJuly 2021 (7872 mm) 2 Maxeon 435:^i,22 5%efficient,compared to a Conventional Panel on same-sized arrays(300 4V,19%efficient, 'y - approx.1.6 ml),7.9%more energy per watt(based or.PVS,vst pan files for avg US climate),0.515.hr slower degradation rate Jordan,ec.al.-Robust PV Degradat,on Methodology and Apo';ca0on'PVSC 2018). Grounding Holes 3 Based on search of datasheet values from websites of top 10 manufacturers per IHS,as ef)une 2021. $ 4 Limits may vary.Refer to local requirements to define the number of micro!nveners per branch m your area. - --- 5 Factory set:o:EEE 1547a-,_ ,' 5470 2014 default settings.CA Pule 21 default settings profile sec during commissioning. N 6 Stardard Test Conditions(1000 W/m=irradiance,AV.1.5,25'9.NI DC voltages fully contained v:ichin the module. A)LSide:1.3 In(32 mm) 7 U:Listed as PURSE and conforms voth NEC 2014 and NEC 2017 690.12:and C22 1-20!5 Ru'e 64.218 Raoid ( on g Shutdown of PV Systems,for AC and DC conductors;when installed according to manufacturer's instrua:ons. Short Side:0.9 in(24 mm) 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations t See vr�na'.stnpowermm/company for more reference information:. Please read the safety and installation instructions for details. For more de:ails,see exterded datasheet vAa•%v.sunpower.com/solar-resources. Soecificatiens mccded in this datasheet are subject to change Without notice. c+ce ivury 002022 SunPower Corporation.AI rights reserved.SUNPOWER,the SUNPOWER:ego and EQU'NOX are 5 00 ReVA registered trademafs of 5unPow'er Corporation in the U.S.MAkEON is a registered trademark of Maxeon Solar LISTED Technologies,Ltd.For more information visit wvAmmaxeon rpm/legal. r�LIF.,,r.,r­<.:ryp�z January 2022 1-800-SUNPOWER s •• • �.��'} +f �, A•� t .iia1. H • .i�,.zr.;+i-`�.i-a'Y�.is Ste. �: '4a, � _}�S• !� �Y� �' �. 1f;•. CS"'" Z _ .:� $ Pp�Y9 '4 L � �-`•�'y,v i���y�:L:=•� X.. ,.pir.,if�' t,�•Y. �, ! {rj 's'.. ..'''d �s� ��" a ..�c'4� �o �,xi �t+�,Y•�_ny- �. -r/ �ww I s ..y3ry'4 `.4 - "•,. ,ntE�f"'''+�.'�?" dr. •,�a 4/+' ,�,',a „s°�..'�,d� 5�„_; .>, `i'.,pY-��:• �, r' �`�`. �t.; k� -421,a'�%.: - .*,ar': te,”-� - tF`%% ..F:4..� ?� "'-•'~ t� ., r'•- �• r P-141O Simple and Fast Iristallation - Integrated module-to-rail grounding ; Pre-assembled mrd and end clamps j Levitating mid clamp for easy placement a? Mid clamp width facilitates consistent.even = _ module spacing Simple,pre-drilled rail splice UL 2703 Listed integrated grounding ---aero Flexible Design � L . r Addresses nearly all sloped residential roofs l: Design in landscape and portrait Rails.enable easy obstacle management " •, Customer-Preferred Aesthetics #1 module and#1 mounting aesthetics Best-in-class system aesthetics Elegant Simplicity Premium,low-profile design Black anodized components SunPower` InvisilMountTM' is a S.;nPower-designed Hidden mid damps and end clamps rail-based mounting system. The InvisiMount system and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics. Built for use with SunPower DC and AC modules Bes-in-class system reliability and aesthetics The InvisiMount product was specifically envisioned and • Combine with SunPower modules and engineered to pair with SunPower modules. The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. /:5, 6 sunpower.com Datasheet O s A3 ice•//`�•J - •� a'�/ 1 III' • © • • . low. . • all lnV%INIbLJF7L COMP• Module*/,Mid Clamp and Rai: Module*1 End Clamp and Rail r" Mid C:amo End Clamp wail k Rail Splice Ground Lug Assembly End Can All -rte+ ourl �bniporlent,Qetajls • ••- _ • • • Ternoerature - 'C to 90'C;-•10' to 194'F) Component Material Weight 3000 Pa uplift -- aid Clarnp Black oxide siainless steel AI51 304 63 g(2.2 oz; l 6000 Pa dewriorce _ — _.._...-- — -...------------._..._.._._........-...... ----...---- End Clamp Back anodized aluminum alloy 6063-T:5 i 110 g 1,3.88 oz) Rail black anodized aluminum alloy.50-05-T6 830.g:'m(9 o<ft) s e Rail Splice Aluminum allo.;6005-T5 830 On(9 o F) 25 year product warranr, l1 ;:rarranues Ground Lug 1 304 stainless r - !ssembly (A2-70 bolt:tin-plated cops er ug) ; 106 S g!m(3.75 oz) -year finish`::af!anry End Cap Blar_k acetal(POl col;Tr er i 10.4 g(0.37 oz) Cert ncatior:s Roof Att6chment Hardware SupportecfbpClass A Fire Rat?d In,4siMouPtSy,,-tern'Dqs;gn Tool, Compos:tior Shingle RafterAftachmeni l Composilon Shingle Roof Decking Attad iment j Roof - : Application Cur.ed a n c=la rT;Ie RoutAtrar7lner, j Un'versal Interface for Other Roof A.ttachrnents i Refer Co root attachment har-aware rnanufacturers documentation: `•Aod'Li e Frame rhsr is compc6b!P.vl'h rrr:nisi Mount sy5tern required for hart{,ware interoperability. ::7.015 SunPrvrer Cerperat ion. All R(gnts Re-e:ped.SUL?ON:FR,the SUNPOWER logo.:?a, 1,14VISINA,O:1NT.:re cis,e rar:cs or re;;rstere. trademarks of:ur.Fower%orporaE on. Ali other trademarks are ti:e pi opei ty of t;,enr respevlva ev:ne,s s.tnpov er.rOrn SpecincaRens Induced m this datcsneet are subjecE to t.hange without noLre. Document#509506 RevC IL _4. 4r'J • Improve Support, Reduce Maintenance Costs SunPower EnergyLink—Plug-and-Play Installation An intuitive monitoring website enables you to: This complete solution for residential and commercial monitoring and See a visual map of customer sites control includes the`--unPovv-er PV Si iPer-visor 6(PVS6)which improves Remotely manage hundreds of sites the instal'adcn process,overall system reliability;and customer Receive elective system reports experience. Locate system issues and remotelydiagnose Compactfcctprir.t for improved aesthetics Diagnose issues online Robust loud connectivity and comprehensive local connectivity Drill down for the status of individual devices Flexible configuration of devices during installation Consumption metering - Revenue-grade production metering(pending) 7­7 Web-based commissioning Remote diagnostics of PVS6 and inverters .. . . Curable UL Tyoe 3R enclosure reduces ma,ntenar ice toss - —•-— __ Easy ntegradon with SunPower eBCS Add Value for Customers –� Robust Cloud Connec�ivity With the SunPower Monitoring System �i• ;- }VyE Multiple s maintain optimal customers can: _ p e options to mainta See what their solar system produces each ' cennectivitY: day,month,or year t.,,X..^� Y Hardr+:fired Ethernet fm, Optimize their solar investment and save on Wi-Fi energy expenses Cellular backup See their energy use and estimated bill savings I See their solar systems performance using the SunPower monitoring website or mobile app i - i Of ALI w C�atasheet �"_�IWER SunPower Monitoring Websites PVS6 SunPower AC Modules en -- -. IIII I - Multiple communication options include Ethernet,Wi-Fi,and cellular. �• 'dumber of SunPawcr AC modules 85 Temperature -22°F to+140°F(-30°C to+60°C) supported per Pi"56 Flumidihr(maximum) 95�,non-cow High-speed it Eternet access via accessible Interne access router or svOrch • Power '00-240 VAC(L-N),50 or 60 Flz • 208`VAC(L-L in 3-phase),60 Hz s o RS-485 I Inverters and meters • one channel of revenue-grade production rr;_tering Integrated Metering hanical • Two channels of consr..mptinn metering 4Veig t 5.5 los(2.5 kg) Ethernet 1 LAN(or opt{oral`8AN)pert Dimensions 1 1.8 x 8.0 x 4.2 in.(30.5 x 20.5 x 10.8 cm) PLC PLC:or SunPower AC rnoduies Enclosure rating, UL50E Type 3R WI-F: 802.11 b/gin 2.4 GHz and 5 GHz Celiuiar LTE Cat-M,1/36 um-rs ZlgBee IEEE 802.15.4 MAC,2 4G!-Iz ISM band We6and MOe Data Storage 60 days Custorner site monitor.ussun-ower.com — :T ------- --- Upgrades Aoma:.._;'Tr-ware upgrade_. Panner sire p mgmLuS.sunnorver.ccm ro;vsers Firefox,Safari,and Chrcme Mobile deuces iPhone'-'iPadl,and Andro;d. Customer apP 1.Create account oriine at:monitor.us.sunpew;er.com. • e 2.On a mobile device,download the Sunft-wer Monitoring Warranty 1C-year Limited Warranty app from Apple App Store-"'or Google Plays"store, 3.Sign in using account ernai'l and paswierd. Certifications UL,cUL,CE,UL 61010-1 and-2,FCC Part 15(Class B) WAVE11ft MsC uL us � � LBTm FCC ID:YAW529027 E503346 530536 RevCa - t RO =- 4 IU�STING ---- -- NEW EQUIPMENT SERVICE �- ------- ------- ---------� JUL - 7 2023 '-120/240, 1PH, 3W PV-SA-1 A (TYPICAL SYSTEM SCHEMATIC, FINAL INSTALLATION MAY VARY, • • AC-COMBINER PANEL o UIf�ES7YL CAL A J � T .�N': . . 2 1 AC—CMB-1 '�a DE$ OOA KWH ---- — ---7 ^{fit Tt 100A � I MAIN C MAIN I PV—SA-2 A i Luc AC—DSC-1 }—�DISC. I I • ® A B N (GRID—TIE) i N • • • 2 1 BKR-1 BKR-M I � I iTYPICAL PV MODULE WITH I I BKR-2 PM-1 I INTEGRAL DC/AC INVERTER L ) - MAIN C/T of FUSED ® I 125 A B N II I N I q EGC II I N I II I I I PV—SA-3 A I I I BKR—a EGC I • N I I I AC DISTRIBUTION I ---- - --� I EGC (EXISTING) I I TYPICAL PV MODULE WITH III GC I I I I INTEGRAL DC/AC INVERTER 6 CU 1——————— —— ——————————————————— -—————————L———————————1—— IRREVERSIBLE BOND, TYP. (GARAGE) (HOUSE) #4CCu L 3-LINE ELECTRICAL DIAG aE��Al / REVISIONS Zimmer, Anne ` ; REENLOGIC° 1105 Dean Drive * ENERGY CutGhogue, NY 11935 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION b2 i 33 pQ' Page 1 of 4 Drawing No: ZMMR-3LD2 Revis-on' NE Revised: 6/30/2023 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 9.216 kW TOTAL KW RATING: (DC POWER) 9.960 kW QTY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL:SPR-M415-BLK-H-AC 24 PV MODULE: (SPR-M415-BLK-H-AC) 415 W DC (NOMINAL), EACH ENPHASE BRAND, MODEL: IQ7HS 24 PV INVERTER: (INTEGRAL TO MODULE) 384 VA, 1.60 A, 240V AC, EACH NOTE: SUNPOWER MODEL SPR-M415-BLK-H-AC INVERTER SETTINGS COMPLY WITH SECTION 7.5.2 AND 7.5.3 OF THE "PSEG LONG ISLAND'S SMART GRID SMALL GENERATOR INTERCONNECTION TECHNICAL REQUIREMENTS AND SCREENING CRITERIA FOR OPERATING IN PARALLEL WITH LIPA'S DISTRIBUTION SYSTEM" REVISIONS Zimmer, Anne REE LOGICO 1105 Dean Drive (3ENERGY Cutchogue, NY 11935 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 2 of 4 Drawing No: ZMMR-3LD2 Revision: 2 Revised: 6/30/2023 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M415-BLK-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M415-BLK-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M415-BLK-H-AC, 1-CIRCUIT OF 6-MODULES PM-1 PV SYSTEM POWER MONITOR SUNPOWER BRAND, MODEL: PVS-6 AC-CMBP AC COMBINER PANEL 250V, 100A, NEMA-1, MAIN-LUG, 1-PH, 3-WIRE BKR-1...BKR-3 CIRCUIT BREAKER, PV-SA-2...PV-SA-3 MATCH PANEL BRAND,2-POLE, 20A BKR-M CIRCUIT BREAKER, PM-1 MATCH PANEL BRAND,2-POLE, 15A AC-DSC-1 AC DISCONNECT (LINE TAP) 250 60A,' EMA-1, DISCONNECT SWITCH, FUSE RATIN 60A ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3,840 WATTS 211-264 VAC 16.10 A AC 240 V,AC PV-SA-2 3,072 WATTS 211-264 VAC 12.88 A AC 240 V,AC PV-SA-3 2,304 WATTS 211-264 VAC 9.66 A AC 240 V,AC PM-1 35 WATTS N/A 0.15 A AC 240 V,AC REVISIONS Zimmer, Anne GEENL®GIC° 1105 Dean Drive G ENERGY Cutchogue, NY 11935 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 3 of 4 Drawing No: ZMMR-3LD2 Revision: 2 Revised: 6/30/2023 CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 1" PVC-40 6 / 6 C THWN-2 1" PVC-40 ' �- D THWN-2 3/4" PVC-40 12 / 12 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUCTTO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: PV ARRAY EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER,MINIMUM PROPOSED ELECTRICAL LOADS REVISIONS Zimmer, Anne EELOGIC° 1105 Dean Drive — ENERGY Cutchogue, NY 11935 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 4 of 4 Drawing No: ZMMR-3LD2 Revision: 2 Revised: 6/30/2023