Loading...
HomeMy WebLinkAbout47083-Z �o�sUFc TOWN OF SOUTHOLD BUILDING DEPARTMENT co z TOWN CLERK'S OFFICE Wo . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47083 Date: 11/8/2021 Permission is hereby granted to: Annicq, Bruno 127 Fort Greene PI Brooklyn, NY 11217 To: Install roof mount solar shingles on existing single family dwelling as applied for and with flood permit. At premises located at: 1230 First St., New Suffolk -7 pcv- SCTM # 473889 Sec/Block/Lot# 117.-7-29 Pursuant to application dated 8/11/2021 and approved by the Building Inspector. To expire on 5/10/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ADDITION TO DWELLING $50.00 Flood Permit $100.00 Total: $300.00 Building Inspector FIELD:INSPECTION REPORT DATE COIVIIVINS ... Jr, FOUNDATION(IST) y --------------------------`. ----- d FOUNDATION(2ND) Aj ROUGH FRAMING:& .'. E-1 y a PLUMBING' INSULATION.PER N.Y. STATE ENERGY CODE FINAL, . + G(?1VIM1VlE T. �t 2 n clo • AT lens z ` y , W Z i .y->ry ' p ®��FFpf �� l� ILDING DEPARTMENT- Electrical Inspector 1 \� 1� , ��p TOWN OF SOUTHOLD oF ° 1Yown Hall Annex- 54375 Main Road - PO Box 1179 1_0 �° Southold, New York 11971-0959 � I ®� Telephone (631) 765-1802 - FAX (631) 765-9502 II ro err southoldtownn ov — seandCcD_southoIdtownnV.qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 11/2/2021 Company Name: Jason Kane Inc. Name: Jason Kane License No.: ME-37295 email: jkane@tesia.com Phone No: 516-306-0126 01 request an email copy of Certificate of Compliance Address.: 127 West Blvd East Rockaway, NY 11518 JOB SITE INFORMATION (All Information Required) Name: Bruno Annicq Address: 1230 1st Street New Suffolk, NY 11956 Cross Street: Phone No.: 646-784-8725 Bldg.Permit#: — L1110&23 email: bruno@annicq.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) Install (74)Tesla Solar Shingles 4.33kw Check All That Apply: Is job ready for inspection?: DYES ®NO ❑Rough In ❑Final Do you need a Temp Certificate?: ©YES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ®Overhead # Underground Laterals ❑1 02 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx PERMIT# Address: Switches Outlets G FI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven W/D Smokes DW Mini Carbon Micro Generator Combo Cooktop Transfer AC AH Hood Service Amps Have Used Special: Comments: 1MtILDING DEPARTMENT-Electrical Inspector WN OF SOUTHOLD o�O e�NoF o��fown Hall Anne xo54375 Main Road - PO Box 1179 oy • °� Southold, New York 11971-0959 ,h O Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(@-southoldtownny.gov — seand(aD-southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 11/2/2021 Company Name: Jason Kane Inc. Name: Jason Kane License-No.: ME-37295 email: jkane@tesia.com Phone No: 516-306-0126 ❑I request an email copy of Certificate of Compliance Address.: 127 West Blvd East Rockaway, NY 11518 JOB SITE INFORMATION (All Information Required) Name: Bruno Annicq Address: 1230 1st Street New Suffolk, NY 11956 Cross Street: Phone No.: 646-784-8725 BIdg.Permit#: email: bruno@annicq.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) Install (74) Tesla Solar Shingles 4.33kw Check All That Apply: Is job ready for inspection?: DYES ®NO ❑Rough In ❑Final Do you need a Temp Certificate?: ®YES ONO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ®Overhead # Underground Laterals ❑1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx ���o�° Dc�coGy TOWN OF SOUTHOLD—BUILDING DEPARTMENT h Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov f Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only q Fr NO. � Building Inspector: NOVO 2021 BUILDING DEPT Applications and forms must be filled out in their entirety.Incomplete TOWN OF SOUTHOLD applications will not be accepted. Where the Applicant is not the owner;an Owner's Authorization form(Page 2)shall be completed. Date:11/2/2021 OWNER(S)OF PROPERTY: Name: Bruno Annicq TCTM #1000- Project Address: 1230 1 st Street New Suffolk, NY 11956 Phone#: 646-784-8725 Email: bruno p9pic com Mailing Address: 1230 1 st Street New Suffolk, NY 11956 CONTACT PERSON: Name:Tesla Energy Operations,lnc./Anais Fernandez Mailing Address: 15 Grumman Rd West Suite 400 Bethpage, NY 11714 Phone#: 631-406-9567 Email: anafernandez@tesla.com DESIGN PROFESSIONAL INFORMATION: Name:Equilux Engineers LLC Mailing Address: 4129 Brittany Drive Ellicott City.MD 21043 „ Phone#: 443-416-7800 Email: hkariuki@equiluxengineers.com CONTRACTOR INFORMATION: Name:Tesla Energy Operations,lnc./Anais Fernandez Mailing Address: 15 Grumman Rd West Suite 400 Bethpage, NY 11714 Phone#: 631-406-9567 Email: anafernandez@tesla.com DESCRIPTION OF PROPOSED CONSTRUCTION El New Structure ❑Addition 2Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Install (74)Tesla Solar Shingles 4.33kw $ Will the lot be re-graded? ❑Yes 12No Will excess fill be removed from premises? ❑Yes ONO 1 Anrnicq A PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes o IF YES, PROVIDE A COPY. [] Check Box After Reading:'The owner/contractor/design professional is responsible for all drainage'and storm water issues as,provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to'the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations.and to admit authorized inspectors on premises and in building(s)for necessary,inspections.False statements made herein are punishable as a Class A misdmeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted (print name): ��,yS y ��, LWu0 th riz d Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF- I'�(AS.S(,I,J ) Ahw- �,Ynl"VA 'V being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contract r,A nt,Corporate Officer, etc.) of said owner or owners, and is duly•authorize( pe orm or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of "r 20011 �/?�/IIL 117oj& Notary ubl'c PATRICIA M. ZULLO NOTARY PUBLIC-STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION No.o1ZU6328662 (Where the applicant is not the owngMr) Qualified in Suffolk County y Commission Expires-08-03-2023 I, Lf-VAJO Nov t residing at 1,2,30 I S J ree4 1V R,fU) T K do hereby authorize 'h �� —Fcsic4 apply on my behalf to the Town of Southold Building Department for approval as described herein. er's Signature Date 2 ,,v, /4(U/v'l� Print Owner's Name 2 Version#93.2-1 PIL July 27,2021 RE: CERTIFICATION LETTER Project/Job#1192340 Project Address: Annicq Residence 1230 1st St New Suffolk,NY 11956 AHJ Southold Town SC Office Bethpage Design Criteria: -Applicable Codes=2020 RCNYS/BCNYS/EBCNYS with 2020 NYSUCS,ASCE 7-16,and 2018 NDS -Risk Category=II -Wind Speed=130 mph(3-s Gust-Vult),Exposure Category C,Partially/Fully Enclosed Method -Ground Snow Load=30 psf -TYP MP:Roof DL=6.5 psf,Roof LUSL=20.8 psf(Non-PV),Roof LUSL=20 psf(PV) Note: Per IBC 1613.1; Seismic check is not required because Ss=0.172<0.4g and Seismic Design Category(SDC)=B<D To Whom It May Concern, Solar Roof TM is a roofing system comprised of both PV and non-PV roofing elements.Please refer to the product data sheets,third-party certifications,and installation documentation for further information. Installation of Solar RoofTM over a single layer of composite shingles is acceptable per the manufacturer's installation instructions.If the existing roof has more than one layer of shingles,or any non-comp shingle roofing,a full tear-off is required.The net installed weight of the Solar RoofTm system is 3.1 psf,is evenly distributed,and no roofing overlays are permitted.Consequently,the net additional loading impact to existing gravity load resisting elements is less than 5%and no further analysis was performed. Where required by the installation manual or conditions above,installer shall perform a full tear-off of all existing layers of roofing material above existing sheathing/decking.Installer shall verify existing roofing,and sheathing/decking satisfy installation instructions.Installer shall verify roof framing is in suitable condition that does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of roofing installation. I certify that installation of the Solar RoofTm system on this job,given no presence of existing structural damage at time of installation; meets the criteria outlined in Section 503 of the IEBC/CEBC(alterations to existing structures)and is therefore permitted by code without alterations or strengthening of the existing framing. NEW yon Digitally signed by `�P�� , A HUMPHRE ; �. G ,/',,HUMPHREY K KARIUKI * �. �" W LU K KARIUKI,.. ' Date:.2021 .07.27 r— ` ' l - 19:32:31 -04'00' 1 .. d SfRUCI'URALON Tesla,Inc. X55 Cle�arliev;kNay Sar,Maieu,CA 94402 T _ 5 L Fi 633 1k;2a F C50 3331029 ® ® 3500 Deer Creek Road,Palo Alto CA 94304 ® L P 650 681 5100 F 650 681 5101 ® C NOV 0 4 2021Ma BUILDING DEPT TOWN OF SOUTHOLD Town of Southold Attn: Building Department RE: Updated plans and permit application Dear Sir/Madam: I am submitting the updated plans Property Address: 1230 1 st Street New Suffolk, NY 11956 I am the applicant Anais Fernandez with Tesla Energy. My phone is 631- 406-9567 or email anafernandez(a)-tesla.com. If you could let me know once review is complete for permit pick-up or mail out. Regards, .mars C5 eawandm Anais Fernandez, Permit Coordinator 36103C 36103C FID 4342 DFIRM ID 36103C VERSION—ID 1.1.1.0 FLD_AR_ID 36103C4325 STUDY_TYP NP FLD ZONE VE 'ZONE_SUBTY VE x , SFHA TF T STAI-IC_BFE 8 ' V_DATUIi1 NAVD88 DEPTH -9999 LEN—UNIT Feet { VELOCITY -9999 VEL UNIT AR REVERT - A AR_SUBTRV BFE_REVERT-9999 DEP REVERT-9999 i � 7 DUAL ZONE r - I 'i SOURCE—CIT 36103C STUDY5 ,l YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured 650-963-5100 Tesla Energy Operations,Inc. 901 Page Avenue 1c.NYS Unemployment Insurance Employer Registration Numberof Fremont,CA 94538 Insured 49-892777 Work Location of Insured(Only required if coverage is specifically limitedto Id.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 02-0781046 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) American Zurich Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"I a" 54375 Main Road WC 1074583-03 Southold, NY 11971 3c.Policy effective period 10/31/2020 to 10/31/2021 3d.The Proprietor,Partners or Executive Officers are N Included.(Only check box if all partners/officers included)all ❑excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box 1 a"forworkers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever isearlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that 1 am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Susan B. Kendziora (Print name of authorized representative or licensed agent of insurance carrier) Approved by: "Cze r �� 10/31/2020 (Signature) (Date) Title:Vice President-Enterprise Support Operations Telephone Number of authorized representative or licensed agent of insurance carrier:800-382-2150 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.nv.clov INTERNAL USE ONLY YORK workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Tesla Energy Operations, Inc. 901 Page Avenue Fremont, CA 94538 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 02-0781046 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) he Prudential Insurance Company of America Town of Southold 3b.Policy Number of Entity Listed in Box"1a" 54375 Main Road Southold, NY 11971-0959 CG-51526-NY 3c.Policy effective period 01/01/2021 to 12/31/2022 4. Policy provides the following benefits: ❑X A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed November 25, 2020 By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 215-658-5178 Name and Title H. Richard Brummett-Statutory Disability Coordinator IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 1111111�11°°1°11°°°°°1111°°°1111!11111111111 Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name CHARLES J PiCARD it Business Name i This certifies that the TESLA ENERGY OPERATIONS INC bearer is duly licensed by the County o`sua01< License Number:HI-62558 FraN%k,NardzW, Issued: 911212019 Commissione, Expires: 9/112021 •ta- RECEIPT SUFFOLK COUNTY GOVERNMENT DEPARTMENT OF LABOR, LICENSING,AND CONSUMER AFFAIRS COMMISSIONER ROSALIE DRAGO P.O.BOX 6100, HAUPPAUGE, NY 11788 (631)853-4600 Today Date: 03/22/2021 Application: ME-37295 Application Type: Master Electrical License Receipt No. 421664 Payment Method Ref.Number Amount Paid Payment Date Cashier ID Comments Check 149 $400.00 03/22/2021 CHRISTII Renewal Contact Info: JASON KANE INC JASON KANE 127 WEST BLVD EAST ROCKAWAY, NY 11518 Work Description: '! `sSuffolk County Dept.of Labor,Licensing&Consumer Affairs f MASTER ELECTRICAL LICENSE Name JASON KANE Business Name This certifies that the bearer is duly licensed JASON KANE INC by the County of suffolk License Number:ME-37295 Rosalie Drago Issued: 04/20/2005 Commissioner Expires: 04/01/2023 APPROVED AS NOTED OCCUPANCY O DATE: ,(L�- B.P.# 0 3 USE IS UNLAWFUL FEE:` 3�D-00 BY: G J°�-L� �T � a � r , NOTIFY BUILDING DEPARTMENT AT R9`J F � ° g E R , i'r '.g 765-1802 8 AM TO 4 °M FOR THE or C,+f" 9 , ,I' FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO •-REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR ' .0. ALL CONSTRUCTION SHALL MEET THE C" WITH ALL CODES OF REQUIREMENTS OF THE CODES OF NEW NEW YORK STATE & TOWN CODES YORK STATE. NOT RESPONSIBLE FOR AS REQUIRED AND CONDITIONS OF DESIGN OR CONSTRUCTION ERRORS. SOUTHOLD TOWN ZBA SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES p® spy V9 N.Y.S.DEC 17•.�M`I:.. cowt,If 1,475 ' :��it PTER I FLOW RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. � �Q�R RM ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A SOLAR ROOF WILL BE INSTALLED OVER BARE SOLID BUILDING CONC CONCRETE DC DIRECT CURRENT UL—LISTED POWER—CONDITIONING INVERTER. OR CLOSELY FITTED SHEATHING, AS FOLLOWS: EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY—RECOGNIZED TESTING -DOC PS-1 COMPLIANT / EXTERIOR GRADE EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN PLYWOOD: MINIMUM 15/32"(11.9 MM) THICK OR FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. -DOC POS-2 OSB ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING MINIMUM 7/16"1HICK (11.1 MM) OR -CLOSELY—FITTED SHEATHING BOARDS: MINIMUM DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, SHEATHING: MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE -C3/4"(19.1 MM) THICK KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. OF BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY SOLAR ROOF CAN ALSO BE INSTALLED OVER PROPERTY LINE POI POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. COMPATIBLE EXISTING ROOFS, AS FOLLOWS: PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL -THREE—TAB COMPOSITION SHINGLE, SINGLE LAYER STEEL STC STANDARD TESTING CONDITIONS TYP COMPLY WITH ART. 250.97, 250.92(B). -ARCHITECTURAL COMPOSITION SHINGLE, SINGLE TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER LAYER VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC SOLAR ROOF WILL NOT BE INSTALLED OVER RAISED PRESIDENTIAL—STYLE COMPOSITION SHINGLE, ROOFS DISCONNECTING MEANS PER ART. 690.31(E). 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN WITH MORE THAN ONE LAYER OF COMPOSITION RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY SHINGLE, EXISTING NON—COMPOSITION SHINGLE UL LISTING. ROOF TYPES LIKE TILED ROOFS. ALL WORK TO COMPLY WITH SECTION R327 OF THE 2020 RESIDENTIAL CODE OF NYS. ® NOV 0 4 2021 BUILDING DEPT. TOWN OF SOUTHOLD VICINITY MAP INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 THREE LINE DIAGRAM Cutsheets Attached LICENSE GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH THE 2020 NYS 26. UNIFORM CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE. 3. ALL WORK SHALL COMPLY WITH THE 2020 NYS FIRE CODE. 4. ALL WORK SHALL COMPLY WITH THE 2020 AHJ: Southold Town BUILDING CODE OF NYS. i+ [REVBY DATE COMMENTS 5. ALL WORK SHALL COMPLY WITH THE 2020 RESIDENTIAL CODE OF NYS. IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIREVA INN 11/1/2021 POWERWALL REMOVED. 6. ALL WORK SHALL COMPLY WITH THE 2020 -= UTILITY. PSE&G—Long Island EXISTING BUILDING CODE OF NYS a CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-1192340 00 CUSTOIdER. DESCRIPTION: rNklola CONTAINED SHALL NOT BE USED FOR THE Bruno Annicq 4.32678 KW PV ARRAY ikolaev TES L n SHA�iT BE olsaOSEXCEPT TESLA OLE ORCIN"� MOUNTING SYSTEM: 1230 1 St St 0 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S TESLA SOLAR ROOF ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES New Suffolk, NY 11956 THE SALE AND USE OF THE RESPECTIVE 7 T s a S 6011 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: AGE NAME SHEET: REV DATE PERMISSION OF TESLA INC. 3.8 kW T2SI0 IncInC 1534000—OO—C 240V 6467848725 COVER SHEET 1 a 11/1/2021 INSTALLATION OF SOLAR ROOF OVER A SINGLE LAYER OF PITCH: 171(4:12) ARRAY PITCH:17° (4:12) COMPOSITE SHINGLES IS ACCEPTABLE PER THE MP1 AZIMUTH:83 ARRAY AZIMUTH:83 MANUFACTURER'S INSTALLATION INSTRUCTIONS. IF THE MATERIAL:Solar Roof STORY.Two EXISTING ROOF HAS MORE THAN ONE LAYER OF SHINGLES, OR ANY NON-COMP SHINGLE ROOFING, A FULL TEAR-OFF IS REQUIRED. THE NET INSTALLED WEIGHT OF THE SOLAR ROOF SYSTEM IS 3.1 PSF. WHERE REQUIRED BY THE INSTALLATION MANUAL OR CONDITIONS ABOVE, INSTALLER SHALL PERFORM Roof access A FULL TEAR-OFF OF ALL EXISTING LAYERS OF ROOFING RELAY MATERIAL ABOVE EXISTING SHEATHING/DECKING. INSTALLER O SHALL VERIFY EXISTING ROOFING, AND SHEATHING/DECKING MEET INSTALLATION INSTRUCTIONS. INSTALLER SHALL VERIFY r r ROOF FRAMING IS IN SUITABLE CONDITION THAT DOES NOT �� ;; 'II j- , EXHIBIT ANY SIGNS OF STRUCTURAL DAMAGE WHICH MAY LC , 0 , ' ' 1 ►--T r 1 I DIMINISH THE CAPACITY OF ITS MEMBERS OR CONNECTIONS _ ' PRIOR TO COMMENCEMENT OF ROOFING INSTALLATION. --- It O I will be installed I r1 F r PV equipment �- out of flood height 6 ft) ; I LJ Lj LA LEGEND �'�E, I i Q (E) UTILITY METER & WARNING LABEL Front Of House Z> I r r id I INVERTER W/ INTEGRATED DC DISCO Pitch I & WARNING LABELS 112 I r I L RELAY 6/12 �� �� � � I � I � t � AUTOMATIC RELAY w L L DC DISCONNECT & WARNING LABELS AC L L AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS Li Li 0 10 Ess ENERGY STORAGE SYSTEM FOR STAND Roof access ALONE OPERATION AC Ind �D DISTRIBUTION PANEL & LABELS O NEW Lc LOAD CENTER & WARNING LABELS �Q �4 KA►JJqIr �- O DEDICATED PV SYSTEM METER ;d .�`� RSD RAPID SHUTDOWN A r l s 4 _ W O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE O HEAT PRODUCING VENTS ARE RED (E) DRIVEWAY STRUCfURAL0 U) INTERIOR EQUIPMENT IS DASHED H U M P H R EY; Digitally signed by v' ,HUMPHREY K KARIUKI K KARI U KI. . °4,-47204'00'T SITE PLAN N i-` Scale: 1/8" = V W E 0 1' 8' 16' S CONFIDENTIAL-THE INFORMATION HEREIN JOB NUMBER: JB-1192340 0 0 CUSTOMER. DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Bruno An n i c BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SY : q 4.32678 KW PV ARRAY Nikola Nikolaev SYSTEM: TT E 5 L n SHALL IT BE DISCLOSED IN WHOLE OR IN TESLA SOLAR ROOF 1230 1 st St 0 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MooulFs New Suffolk, NY 11956 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (74) Tesla # SR60T1 TESLA EQUIPMENT,VATHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV: DATE PERMISSION OF TESLA INC. 3.8 kW Tesla Inc 1534000-00-C 240V 6467848725 SITE PLAN 2 a 11/1/2021 • GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE * Panel Number.QOC20U100S Inv 1: DC Ungrounded INV 1— (1) 3.8 kW Tesla Inc 1534000—OD—C(24OV) — (74)Tesla#SR6OT1 Meter Number:98300690 Tie—In: Supply Side Connection Solar Roof PV Module; 58.47W,52.11W PTC, Textured Overhead Service Entrance INV 2 Voc: 13.34 Vpmax: 10.99 INV 3Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 100A MAIN SERVICE PANEL 11Ve 2C 1 E) 10OA/2P MAIN CIRCUIT BREAKER (E) WIRING CUTLER—HAMMER Disconnect 3.8 kW Tesla Inc 1534000-00—C (240V) 6 5 _2 v D 20A A Ll �C GD r0OA/2P B 11 Dc+ (E) LOADS GND ------------------------------------- - EGC ---� DC+ ❑ DC+ MP 1: 2x37 -- DG -- - DG I 4 -♦ B 3 2 1 I I I I I o I Z � I I --- - GEC; TO 120/240V SINGLE PHASE UTILITY SERVICE I I I A Voc* = MAX VOC AT MIN TEMP GD Please see MCI wiring detail page for more information POI (1)Gro rLd Ro# D (I)CUTLER—HAMMER#DG221NRB n g (1)Junctian fax A (1)EE-000550-001 MC4 Y—Connector, Receptacle D� 5r8 x 8, Co per Disconnect 30A 240Vac Fus�le,NEMA 3R / Metal; 6 x6'x4', Boz w/cover Nema 3R — 1 EE-000550-000 MC4 Y—Connector,Plug —(2)ILSCO!IPC 4�0—#6 —(1)CUTLER—kiA�1MER DG030H8 Insulafion Piercing Connector, Main 4/0-4,Tap 6-14 Ground eutral lit 30A, General Duty(DG) C (I)Pass Through Box PU (8)Teslo Ma, 60OV. 13A S -(2)FERRAZ SHAMUT�k632 SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Fuse Reducer A Fuse for 60A Clip,250V AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. —(1)CUTLER—HAMMER �S16FK Class R Fuse Kit —(2)FERRAZ SAA2 OV,# au 2ORRKS PV BACKFEED OCP Fuse;1 AWG#6,THWN-2, Black (I)AWG#10,THWN-2,Black (2)PV Wire, AWG 10,Black Voc 539.39VDC Isc—11.3 ADC (4)PV Wire, AWG 10,Black Voc =539.39VDC Isc =5.65 ADC © (1)AWG#6, THWN-2, Red O IsH(I)AWG#10,THWN-2,Red 4) Vmp 406.63VDC Imp=10.64 ADC O Vmp 406.63VDC Imp=5.32 ADC (1)AWG#6, Solid Bare Copper GEC Vmp =240 VAC Imp=16 AAC (I)AWG#10,THWN-2, Green EGC Vmp =240 VAC Imp=16 AAC LJ . ................ 1 Conduit Klt; 3 4 EMT — 1 Conduit Klt; 3 4 EMT (2 PV Wire, AWG 10, Black Voc* 539.39VDC Isc=11.3 ADC . ........(.)..oyitK . ./ ................... ..... .... .............. ........ .)........ ./ ... .... .......... .. ..... ................. O (I Conduit; 3/4'LFMC Vmp =406.63VDC Imp=10.64 ADC ®�(1)AWG06, THWN-2 Black Voc* =539.39VDC Isc=11.3 ADC (1)AWG#10, THWM-2, White Vmp =406.63VDC Imp=10.64 ADC (1)AWq#10, THWN72,.green,. EGC,,,, (1)Conduit,Kit;.3/4',FMT.,,.,,,,,. CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER: JB-1192340 00 CUSTOMER. DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Bruno Annicq 4.32678 KW PV ARRAY Nikola Nikolaev BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSTEM: 5 L n SHALL IT BE DISCLOSED IN WHOLE OR IN TESLA SOLAR ROOF 1230 1 st St 0 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES: New Suffolk, NY 11956 THE SALE AND USE OF THE RESPECTIVE (74) Tesla # SR60T1 TESLA EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME SHEET. REV. DATE- PERMISSION ATE PERMISSION OF TESLA INC. INVERTER:kw Tesla Inc 1534000-00—C 240V 6467848725 THREE LINE DIAGRAM 3 a 11/1/2021 WARNING:PHOTOVOLTAIC SOURCE Label Location: Label Location: Label Location: (C)(CB)(JB) INV SOLAR PV SYSTEM SolarEd a and,Delta M-Series and,Telsa Inverter Per Code: �EQUIPPED' • ' • RAPID Per code: EQUIPPED WITH RAPID Per Code: NEC 690.31.G.3 SHUTDOWN NEC 690.56.C.3 SHUTDOWN 690.56(C)(1)(a) Label Location: TORNRAPM PHOTOVOLTAIC DC (DC)(INV) M%IN Per Code: 59iT0H THE DISCONNECT w"POSmON TO E C NEC 690.13.8 Label Location: SYSTEM1 N+�� PYPANELS CAUTION (POI) SHOCKHAZARD DUAL'• - • - Per Code: INSHEARRAY. MAXIMUM VOLTAGE Label Location: SEC• ■ • _CE IS NEC 705.12.13.3 MAXIMUM CIRCUIT CURRENT (DC)(INV) OVOLTAIC SYSTEM Per Code: MAX RATED OUTPUT CURRENT NEC 690.53 OF Label Location: OR . � � (POI) INSTALLED) INVERTER Per Code: OUTPUTCONNECTION NEC 705.12.B.2.3.b ■• NOT RELOCATE Label Location: i THIS OVERCURRENT WARNING (DC) (INV) DEVICE Per Code: SHOCKELECTRIC _■ 690.41.8 IF -• ■ ■ ■ NORMALLY GROUNDED CONDUCTORS Label Location: UNGROUNDED • ■ ENERGIZED WARNING (DC)(INV) SHOCKELECTRIC -■ THE DC CONDUCTORSOF PHOTOVOLTAIC Label Location: UNGROUNDEDAND PHOTOVOLTAIC (AC)(POI) MAY BE ENERGIZED DISCONNECT Per Code: NEC 690.13.13 SOLA. .V SYSTEM Label Location: ABB/Delta Solivia Inverter Label Location: EQUIPPED WITH RAPID Per Code: MAXIMUM AC A (AC)(POI) SHUTDOWN 690.56(C)(1)(b) OPERATING Per Code: TURN RAPID MAXIMUM AC OPERATING VOLTAGE NEC 690.54 SHUTDOWN SWITCH TO THE`OFF' POSITION TO SHUT DOWN CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN Label Location: ENERGM IN SUNLIGHT WARNING (AC)(POI) (AC):AC Disconnect HAZARD Per Code: (C): Conduit ELECTRIC •CK DO NOT TOUCH TERMINALS NEC 690.13.13 (CB): Combiner Box TERMINALS ON :• LINEAND (D): Distribution Panel LOAD . . (DC): DC Disconnect IN THE •- POSITION (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection Label Set T = SLn 1 GENERAL NOTES 0 DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 GD SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.B.2.1) MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ J-BOX I J-BOX J-BOX J-BOX J-BOX J-BOX MCI MCI RETROFIT PV MODULES DC- • MCIS ARE LOCATED AT ROOF LEVEL, JUST UNDER THE PV MODULES IN ACCORDANCE WITH 690.12 REQUIREMENTS 1 • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH — NUMBER OF MODULES BETWEEN MCI UNITS = 0-3 — MAXIMUM NUMBER OF MODULES PER MCI UNIT = 3 FJ-—BO J-BOX J-BOX J-BOX — MINIMUM NUMBER MCI UNITS = MODULE COUNT/3 MCI *Exception: Tesla (Longi) modules installed in locations where the max Voc for 3 modules at low design temperature exceeds 165V shall be limited to 2 modules between MCIs. PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR MORE INFORMATION 1 �— (2)AWG, PV Wire, 600V, Black DC T - 'S L n GENERAL NOTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.B.2.1) GD • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ DIODE DIODE DIODE DIODE DIODE DIODE DIODE MCI SOLAR ROOF TILES DC- o MCIS ARE LOCATED AT DECK LEVEL, JUST UNDER THE 1 DIODE DIODE DIODE DIODE DIODE DIODE DIODE MCI TILES IN ACCORDANCE WITH 690.12 REQUIREMENTS • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH — NUMBER OF TILES BETWEEN MCI UNITS = 0-10 DIODE DIODE DIODE DIODE DIODE DIODE DIODE — MAXIMUM NUMBER OF TILES PER MCI UNIT = 10 MCI — MINIMUM NUMBER MCI UNITS = TILE COUNT/10 DIODE DIODE DIODE DIODE PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR MORE INFORMATION 1 — (2)AWG, PV Wire, 600V, Black DC SOLAR INVERTER Tesla Solar Inverter provides DC to AC conversion and integrates with the Tesla ecosystem, I including Solar Panels,Solar Roof,Powerwall,and vehicle charging,to provide a seamless T=s T S 5 L A sustainable energy experience. KEY FEATURES 5 " ! Integrated rapid shutdown,arc 2x the standard number of MPPTs for fault,and ground fault protection high production on complex roofs I • No neutral wire simplifies installation ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS MODEL NUMBER 1534000-xx-y 1538000-xx-y Dimensions 660 mm x 411 mm x 158 mm(26 in x 16 in x 6 in) OUTPUT(AC) 3.8 kW 7.6 kW Weight 52 Ib' - - - Nominal Power 3,800 W 7,600 W Mounting options Wall mount(bracket) r.-. Maximum Apparent Power 3,328 VA at 208 V 6,656 VA at 208 V 3 Door and bracket can be removed for a mounting weight of 37 Ib. �-- 3,840 VA at 240 V 7,680 VA at 240 V I Maximum Continuous Current 16 A 32 A o0 Breaker(Overcurrent Protection) 20 A 40 A O0 I Nominal Power Factor 1-0.9(leading/lagging) THD(at Nominal Power) <5% 00 � • t' "- - INPUT(DC) 660 mm o� MPPT 2 4 0- _.:..= Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC DC Input Voltage Range 60-55 OVDC '4 DC MPPT Voltage Range 60-480 VDC' y Maximum Current per MPPT(Imp) 13 A 1I158 f� 411 mm Maximum Short Circuit15 A II mm I Current per MPPT(I,c) ENVIRONMENTAL SPECIFICATIONS PERFORMANCE SPECIFICATIONS Operating Temperature -300C to 450C(-220F to 1130F)^ Peak Efficiency 98%at 208 V 98.4%at 208 V Operating Humidity(RH) Up to 100%,condensing 98.1%at 240 V 98.6%at 240 V Storage Temperature -300C to 700C(-220F to 1580F) SOLAR INVERTER CEC Efficiency 97.5%at 208 V 97.5%at 208 v --------- --- ----- - --- --------- ------- ----- -- 97.5%at 240 V 98.0%at 240 V Maximum Elevation 3000 m(9843 ft) Allowable DC/AC Ratio 1.7 Environment Indoor and outdoor rated 3.8 kW 17.6 kW Customer Interface Tesla Mobile App Enclosure Rating Type 3R Tesla Solar Inverter completes the Tesla home solar system,converting DC power from solar to AC power for home consumption.Tesla's Internet Connectivity Wi-Fi(2.4 GHz,802.11 b/g/n), Ingress Rating IP55(Wiring compartment) Ethernet,Cellular(LTE/4G)' renowned expertise in power electronics has been combined with robust safety features and a simple installation process to produce an - - - -- -- - -- - --- - --- Pollution Rating PD2 for power electronics and terminal wiring AC Remote Metering Support Wi-Fi(2.4 GHz,802.11 b/g/n), compartment,PD3 for all other components outstanding solar inverter that is compatible with both Solar Roof and traditional solar panels.Once installed,homeowners use the Tesla RS-485 --- - - -- - -- -- --- - - - - --- mobile app to manage their solar system and monitor energy consumption,resulting in a truly unique ecosystem experience. - - - -- - -- - - -- Operating Noise @ 1 in <40 db(A)nominal,<50 db(A)maximum Protections Integrated arc fault circuit interrupter — — — (AFCI),Rapid Shutdown "For the 7.6 kW Solar Inverter,performance may be de-rated to 6.2 kW at KEY FEATURES ---- -- 240 V or 5.37 kW at 208 V when operating at temperatures greater than Supported Grid Types 60 Hz,240 V Split Phase 45°C • Built on Powerwall 2 technology for Designed to integrate with Tesla Powerwall and Tesla App 60 Hz,208 V Wye ------ --- - exceptional efficiency and reliability COMPLIANCE INFORMATION 3.8 kW and 7.6 kW models available Maximum current. -__- ---------- ---------------- ------------ • WI-Fi, Ethernet,and cellular connectivity :Cellular connectivity subject to network operator service coverage and signal Grid Certifications UL 1741,UL 1741 SA,IEEE 1547,IEEE 1547.1 strength. -__---__---�_ - —_- with easy over-the-air updates Safety Certifications UL 1741 PVRSS,UL 16996,UL 1998(US).UL 3741 Emissions EN 61000-6-3(Residential),FCC 47CFR15.109(a) T = S L Pi NA TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICE The Tesla Solar Shutdown Device is part of the PV system rapid I shutdown(RSD)function in accordance with Article 690 of the applicable NEC.When paired with the Tesla Solar Inverter,solar array shutdown is initiated by any loss of AC power. o ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS ---------- — ------------------------------------ ------- Nominal Input DC Current Rating(IMP) 12A Electrical Connections MC4 Connector Maximum Input Short Circuit Current(Isc) 15 A Housing Plastic Maximum System Voltage 600 V DC -------------------------- ---------------------- Dimensions 125 mm x 150 mm x 22 mm (5inx6inxlin) Weight 350 g(0.77 Ib) RSD MODULE PERFORMANCE Mounting Options ZEP Home Run Clip M4 Screw(#10) Maximum Number of Devices per String 5 M8 Bolt(5/16") - .- --- ---- ---- --- -- ---- Nail/Wood screw Control Power Line Excitation Passive State Normally open jQ Maximum Power Consumption 7 W -- ---- ---- Warranty 25 years __ __ 250 mm� ____ ____ COMPLIANCE INFORMATION o M4 Screw 650 mm 150 mm M8 Bolt Certifications UL 1741 PVRSE,UL 3741, PVRSA(Photovoltaic Rapid e o Shutdown Array) Nall/ RSD Initiation Method PV System AC Breaker or Switch Wood Screw Compatible Equipment See Compatibility Table below '_ ____ ---- ENVIRONMENTAL SPECIFICATIONS 22 m 125 mm Ambient Temperature -40°C to 50°C(-40°F to 122°F) Storage Temperature -30°C to 70°C(-22°F to 158°F) Enclosure Rating NEMA 4/IP65 UL 3741 PV HAZARD CONTROL (AND PVRSA) COMPATIBILITY Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with the Tesla Solar Inverter and Solar Shutdown Devices.See the Tesla Solar Inverter Installation Manual for detailed instructions and for guidance on installing Tesla Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS(where xxx=405 to 450 W,increments of 5) 1 Solar Shutdown Device per 3 modules' Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules 'Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between MCIs. T = 5 L Pi HL..2021-0<--0"' TESLA.COM/ENERGY WARNING:To Reduce the Risk of Injury,read all instructions WARNING:To Reduce the Risk of Injury,read all instructions PV Hazard Control System:Solarglass Roof PVHCS PV Hazard Control System:ZS PVHCS UL 3741 Report Date 8-12-21 (Applicable to ZS Comp,ZS Span,ZS Ramp,and ZS Seam) PV Rapid Shutdown Array,UL 1741 Category QIJR,Report Date:2021-06-21(Rev 8-10-21) UL 3741 Report Date 8-12-21 PV Rapid Shutdown Array,UL 1741 Category QIJR,Report Date:2021-06-11(Rev 8-10-21) PV Hazard Control Equipment and Components Firmware Versions Certification PV Hazard Control Equipment and Components Function Manufacturer Model No. and Checksums Standard Firmware PVRSE Mid Circuit MCI-1 Versions and Certification Interrupter(MCI) Tesla 15503792 N/A UL 1741 PVRSE Function Manufacturer Model No. Checksums Standard Inverter Tesla 7.6 kW:15380002 V4,CEA4F802 UL 1741,1998 Interrupter(MCI)PVRSE Mid Circuit Tesla 1 MCI-1 VICI-1 2 N/A UL 1741 PVRSE 3.8 kW:15340002 V4,FF76E4E1 PVRSS/PVRSE 7.6 kW:15380002 V4,CEA4F802 UL 1741, 8 199 PV Module Tesla SR60T1,SR72T1 N/A UL 61730 Inverter Tesla 3.8 kW:15340002 V4,FF76E4E1 PVRSS/ 199 Diode Harness Tesla SRDTH N/A UL 9703 VRSE Hanwha/ Q.PEAK DUO BLK-G5/SC310-320 SR-BJ2X PV Module N/A Q-CELLS Q.PEAK DUO BLK G6+/SC330-345 UL 1703 PV Wire Jumper(s) Tesla SR-BJ3X N/A UL 9703 Tesla(Longi) Tesla Txxxs UL 61730 SR-BJ4X (where xxx=405 to 450,increments of 5) SR-BJMini ZEP 850-1613-001 Pass-Through Box Tesla SRPTB-4 N/A UL 1741 Interlock Tesla ZEP 850-1388-001 N/A UL 2703 ZEP 850-1281-001 PVHCS Initiator' ZEP 850-1511-001 UL 467 (See installation Non-Specific N/A N/A N/A Ground Zep Tesla ZEP 850-1172-002 N/A UL 2703 requirements below) ZEP 850-1509-001 1 Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC 690.12 requirements. DC Wire Clip Tesla ZEP 850-1448 001 N/A UL 1565 2 Applies to variations of this part number with suffix of two numbers and one letter. Homerun Wire Clip Tesla ZEP 850-1510-001 UL 1565 Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual PVHCS Initiator' equipment and component PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. (See installation Non-Specific N/A N/A N/A requirements below) PVHCS Installation Requirements 1 Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC 690.12 requirements. Max System Voltage 600 Vdc 2 Applies to variations of this part number with suffix of two numbers and one letter. PVHC Maximum Circuit Voltage(Array Internal Voltage After Actuation) 165 Vdc(cold weather open circuit) Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual Max Series-Connected Panels between MCls: 10 equipment and component PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. Other Installation Instructions: PVHCS Installation Requirements 1. An MCI must be connected to one end of each series string or mounting plane sub-array string. Max System Voltage 600 Vdc 2. Verification that MCIs are installed with 10 or fewer modules between MCIs shall be documented for PVHC Maximum Circuit Voltage(Cold weather array internal voltage after actuation) 165 Vdc inspection,by voltage measurement logs and/or as-built string layout diagrams. Max Series-Connected Modules Between MCls: 3' 3. The dedicated PV system AC circuit breaker or PV system AC disconnect switch shall serve as the PVHCS `Exception:Tesla(Longi)modules installed in locations where the max Voc for 3 modules at low initiator and shall be sized and installed in accordance with NEC requirements. The specific part shall be design temperature exceeds 165V shall be limited to 2 modules between MCIs. identified on the as-built system drawings. Other Installation Instructions: 1. An MCI must be connected to one end of each series string or sub-array string. �� 2. Verification that MCIs are installed with 3 or fewer modules between MCIs shall be documented for Certification Mark of UL on the installation instructions is the only method provided by UL to identify products inspection,by voltage measurement logs and/or as-built string layout diagrams. manufactured under its Certification and Follow-Up Service.The Certification Markfor these products includes 3. The dedicated PV system AC circuit breaker or PV system AC disconnect switch shall serve as the PVHCS ' the UL symbol,the words"CERTIFIED"and"SAFETY,"the geographic identifier(s),and a file number." initiator and shall be sized and installed in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. Certification Mark of UL on the installation instructions is the only method provided by UL to identify products Lmanufactured under its Certification and Follow-Up Service.The Certification Mork for these products includes the UL symbol,the words"CERTIFIED"and SAFETY,"the geographic identifier(s),and a file number." 14-CELL PV MODULE T S L Fi MODEL#: SR60T1 SOLAR ROOF DATASH EET a j FOR FULL TEAR-OFF AND OVERLAY INSTALLATIONS f , i ELECTRICAL SPECIFICATIONS r: Maximum open circuit voltage rating of connected branch circuits per diode(at STC): 13.34 V Maximum series fuse rating: 10 A Maximum system voltage:600 V „w:°•np Irradiance(W/mz) Temp.(Celsius) Voc(V) Vmp(V) Isc(A) Imp(A) Pmax(W) 1000 25 13.34 10.99 5.65 5.32 58.47 These electrical characteristics are within±5%of the indicated values of Isc,Voc,and Pmax under standard test conditions(irradiance of 1000 W/m2,AM 1.5 spectrum, and a cell temperature of 25°C or 77°F). MECHANICAL SPECIFICATIONS Dimensions:430 mm x 1140 mm -- — Thickness:Appx. 5 mm module thickness with 35.3 mm maximum height from deck Principal Materials: Glass, Polymers, Fiberglass and Silicon Installed System Weight:Textured Glass: 15 kg/M2 or 3.1 psf (Installed weight includes all components of system above roof sheathing or existing roof covering) ROOF PITCH RANGE 2:12-24:12 Certain features can be installed up to 62:12 CERTIFICATIONS UL 61730(UL Listed); UL 9703(UL Listed); UL 1741 (UL Listed) UL 790 Class A(ETL Listed);ASTM D3161 Class F(ETL Listed);TAS100(ETL Listed) T = S L n TESR-DS-0261-21 SOLAR ROOF FLUSH MOUNT DATASHEET 2 SHEATHING SPECIFICATIONS Solar Roof will be installed over bare solid or closely fitted sheathing,as follows: • DOC PS-1 compliant/exterior grade plywood: minimum 15/32"(11.9 mm)thick or • DOC POS-2 OSB sheathing: minimum 7/16"thick(11.1 mm)or • Closely-fitted sheathing boards: minimum of 3/4"(19.1 mm)thick Solar Roof can also be installed over compatible existing roofs,as follows: • Three-tab composition shingle,single layer • Architectural composition shingle,single layer Solar Roof will not be installed over raised presidential-style composition shingle, roofs with more than one layer of composition shingle, or existing non-composition shingle roof types like tiled roofs. ROOFING MODULES,FULL AND PARTIAL PV MODULE Model#SRNFT1/6,#SRNFTI/3,#SRNFTI/2, Model#SR60T1 #SRNFT2/3,#SRNFT5/6 and#SRNFTI Listed to UL 61730 Listed to UL 61730 UL 790 Class A o Listed to UL 790 Class A ASTM D3161 Class F ASTM D3161 Class F TAS100 TAS100 o" METAL TILES, FULL AND PARTIAL UNDERLAYMENT Model#SRMTTI/6,#SRMTTI/3,#SRMTTI/2, Model#SR-SAUL-1 or FT Cobalt FR #SRMTT2/3,#SRMTT5/6,#SRMTT1 ASTM D1970/ICC AC48 Listed to UL 1897 ICC AC188 Listed to UL 790 Class A ASTM El 08 Class-A ASTM D3161 Class F TAS100 DIODE HARNESS PASS THROUGH BOX Model#SRDTH Model#SRPTB-4 UL 9703 UL 1741,File#E318357 Listed(ZKLA)"PV Wire" Short and long lead variants o interchangeable v 0 T = S L n TESR-DS-0261-21 SOLAR ROOF FLUSH MOUNT DATASHEET 3