Permit#: 50260 Date: 1/26/2024
Permission is hereby granted to:
Kre er, Michael
80 Rockwood Ln
Greenwich, CT 06830
To: install generator as applied for per Trustees approval.
At premises located at:
985 Ba Shore Rd Green ort
SCTM # 473889
Sec/Block/Lot# 53.-3-13.1
Pursuant to application dated 12/26/2023 and approved by the Building Inspector.
To expire on 7/27/2025.
Fees:
ACCESSORY $125.00
ELECTRIC $100.00
CERTIFICATE OF OCCUPANCY $100.00
Total: $325.00
Buil g Inspector
,xszxwrr�a
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone(631) 765-1802 Fax (631) 765-9502 hltp�,:I r at�l as ^;l n
Date Received
APPLICATION FOR BUILDINGPERT
For Office Use Only ° ¢
o
b -
PERMIT NO. Buildinglnspector,,—.... _ ������,� a°
Applications and forms must be filled out in their entirety.Incomplete
applications will not be accepted. Where the Applicant is not the owner,an m
Owner's Authorization form(Page 2)shall be completed.
Date:12 11 2023
OWNER(S)OF PROPERTY:
Name:Kreger SCTM#1000-53-03-13.1
Project Address: +0S5 Bay Shore Road, Greenport, NY 11944
Phone#:213-713-2310 lEmail:MAKreger@gmaii.com
Mailing Address:80 Rockwood Lane, Greenwich, CT 06830
CONTACT PERSON:
Name:Eugene Burger
Mailing Address:2215 Pine Tree Road, Cutchogue, NY11935
Phone#:631 484 9763 Email:burgerconstruct@aol.com
DESIGN PROFESSIONAL INFORMATION:
Name:
Mailing Address:
Phone#: Email:
CONTRACTOR INFORMATION:
Name:Burger Construction, Inc.
Mailing Address:PO Box 934, Cutchogue, NY 11935
Phone#:631 734 5217 Email:burgerconstruct@aol.com
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
F±1Other Generator $
Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes IgNo
1
PROPERTY INFORMATION
Existing use of property:Residence Intended use of property:Residence
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? ❑Yes *No IF YES, PROVIDE A COPY.
Check
a�:236 of the Town Code. APPAf'i:"w`IIG�r, dlii,.L. The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
KATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Gass A misdemeanor pursuant to Section 210AS of the New York State Penal law.
Application Submitted By(print name): Eugen Burger RAuthorized Agent ❑Owner
Signature of Applicant: D5 NIC D.BUNCH
Notary Public,State of New Y'orl(
No.01BU618 05'0
l ualified in Suffolk Courgy
STATE OF NEW YORK) Corrl"Ijssfon Expres APril 14,2# T
SS:
COUNTY OF
being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the
(Contractor,Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this 111-
y of L.e Ce/Y1 JQI� , 20 � �"�° 4,64/1(�A
Notary Public
R"rymrvry W1III �� .i' )111K)
)' Ill �i� °IIUmirl"�'IF '�'�� �'(�,
(Where the applicant is not the owner)
Michael Kreger residing at 1085 Bay Shore Road
Greenport, NY do hereby authorize Eugene Burger to apply on
my b h<e T wn o Building Department for approval as described herein.
Owners Signature
' ate'
Michael Kreger
Print Owner's Name
2
t
Glenn Goldsmith,President �1 sftp�° Town Hall Annex
A.Nicholas Kru ski,Vice President 54375 Route 25
p � "' P.O.Box 1179
John M.Bredemeyer III y1 M Southold,New York 11971
Michael J.Domino • . Telephone(631) 765-1892
Greg Williams Fax(637.,) 765-6641.
D
D
BOARD OF TOWN TRUSTEES AIir! 7 6 2OZ1
TOWN OF SOUTHOLD
CERTIFICATE OF COMPLIANCE B DING DEPT-
TOWN OF So')TI O D
1842C Date:July 27,2021
THIS CERTIFIES that tbe.deni61iti6n dd oeicisl on ttr . re111n '`hri 'ideck sloe
r brlki aaw : A/C` itas"°
wl. wy odes s.alched,tou spade o wwella ed: h "o -
lafi:and`rd t wd ex�lstiri ". a tac.t�nk dad-ldac lint . cats 1 caked° =8 ' onr we lends n ct new
dwcllia tc ,he taco' 5 'arc whtl d 2two,°2 a t! arches ooe'S7s .
rooted :o�°ch ra th fro t.s wath de°of dwellin aft- and 21ti aid °i��c on`' x nortl r+rest side'
r wveltin ,with a r a "tel 311s . .d stairs"es in dovwn` ' nw the oiled" orches°toAlre. racriil�,
kw 1,* ffl..:o�t lo'or llornrdr ridwa°1720" '"fl.` ol;ivitl�'ddc&.*ith'130 '.ft,of:,.00lrc" iia nc wr 32s A.
enerritol.of'c "' Iola r i e ma r t o las f condo t slab n 4' l '666 efi:odsaate
fencih .to be-46c" l3 5':jroaxa "nil retl rtds.:in�ll.an rt ,s n d leaclw �poots
t"b locat l 100,id t frasn etlarids th6ree re"vacua tli .epi ti se t' tem.loc ted / 81� from
.yeflands ryath.a.ad ac s th'a"tas�oaal zdai`1"r i lee" ' ' icttriai re rrfi a7re the eacistw wa dr' ry,
aracreasraa .itstlarea.f"roma 2 ASO a ..,1..s ft,'.extsin ra e°wat "wyood s�r��i add j b;te din
i ts1.a sty f dtfers tr d'le ddts`,to di cells d he dwv ltn ^lluu a�n,eord rto'co tarn storm ra r
staff loan 17a,ssur Abe 13hfldt ial"'ll q'95 : n, 104A ,of
RMNMed
At 1;,08513a 'rhordrl ° rad otlw
d
Suffolk County Tax Map#1000-53-3-13.1
AUG �onforms to the application for a Trustees Permit heretofore filed in this
131 T1f,D1�K fC IBgted April 13,2018 pursuant to which Trustees Wetland Permit#9433 Dated
rrol -N
April 17,2019 was issued and Amended on January 20,2021 and conforms to all of the
requirements and conditions of the applicable provisions of law.
The project for which this certificate is being issued is for the d' cilitaon ofexi °1n oristry° °
d.v ellin ': ici oo vv imod deck shed:wall ad to attached,t west side9ta dwwelhn died w�wltlf, fi
wo`€ a m" i�cli twallwva : Aft �r�tit cih s1 lb dererriciyd"e � tt t se fidlfadkaad leach rt ools°locatt�ed, a
8 'froetlands construoty 1s , .tiro s " rlw�rdll' to b lccatecl 55'scala w slap wVatt i.
twd- 2 +rodjed orcl esr oris 57 kfl coo a µ, orcla,on tl�e front soaathw ode f"wa 11` argil atad 21 s ft,µ
rod eel orgh on,66 n westM ofdw dl wrath a row tel COs of stairs leadin d wn:
nfitl or"c es t d' t"n1t.ndr 1 artdrr r.;shwdenew" "'T,2Qs "fk rwl wrtl° edlr with;
1` s ..o£ adl ccs `in new r tl.. a eratarncrdte slala eww 11n. "` ui`°aiaeaat on;9 5s"
d" to s1 new4'` t ool ert l sure eaacia� to a located 13 ,'''arm a 'ward ed e f etlansfs
insta ring d t"d"t ag aaad rwachin o, s,tbW-Caudated 100,reeTfrorn.wellandsilueres' xelar'In
e istan se lc ste lcacatatcl. A"l38'" oaia wwre ands°wvrtli a sc tio' strirra t1 ¶tis.ou We Trustde
W isdictign ,reddnfi ure th& xisti dfi VdW "idcreasiri its a es:froriv '; lis ,ft:tri1 s . .� 0 istir
ara a writln.wwoo .aod stip to rrsia�c .itaii arf nt r t Iesixsc d wrlt to ti Y
dw bilin °arid.garage in,orderao.eentaxn,,sformwvater, nrr�o ��- 3 s r arace> effiMr af.`ii' i .t. ndtw
'erir f lautfer d '1:�� "s .ft.w�viiln'� Ll ,�� reserved rea,
The certificate is issue o,,.Michael f e 'er owner of the aforesaid property.
Authorized Signature
SITE PLAN
UCHAEL KREGER
E ROAD, GREENPORT
- 53 - 3 - 13.1
T(20%OF 39,624) S GREEK T'da B acr c7 2
Proposed "No Disturbance Buffer": 1 105 SF p�pE �'Gsowhold ,
(To be established over a revegetated area) j
z,336sQ.Fr. S877447E
8825O.F.. . 72.86' S &4,7"`
40
965O.FT. Revegetate Area of Existing Ab --------- 'E
3,314SO.F.. �a'" _. .. (. .. — 63,� € .,I}
No Disturbance Buffer: 102 sq.ft. I
j �La�`'`��—.� ��' "' aintara 4'Wide Foot Path to 'IM r
^r �p ..,Fal} '(-dc1 cleared€mf usa hand[els;inducting but
7(10%OF 39,624) (t4` l' t aoe: m� I
t - � ) L<AT °t s not limited to hated prunes hedge trimmers,
weed whackers or an 8-inch bladed brush trimme
.1,95250.FT. _J"� PROJECT L.MM
640 SOFT. FENCE CAM-AUX SLT
£A6
130S0.FF.. ; TAO # _ . a wCIK FENFENCE)87SSQ.FT.
8825O.FT. !:
4,4795Q.FT.
COASTAL BARRIER-- UNE
RESOURCE UNE _
Permanent 4'Tall Pool Fence
JINE
be Erected Along Edge of No Turf Zo )
Q.FT(20%OFz8,260) LQ� 'sr 900SO.FT. �nsQ.Fr - (nr)
g t Proposed No Disturbance Buffer"
L _ _ (To be Established over existing vegetation)
; 10
:).FT.(20%OF28,260) OWN
't '
g a I •'
-1,952S
Q.Fr. r - / � -= tom—: �EDGE OF Proposed "No Turf Zone": 1,265 SF
- 640SQ.FT. . � _ - _. Cw.. CLEAWNG
1305 FT. rn� l _..-t.:` / .1, .,. F; ( .s tom-)
875 SQ.FT. ' I 1OS. 1 ` ' I - ,,. I € ,.
900SO.FT.
= 865Q.Fr ,. 1 I t ', %P N/o/F
TH
4,5835Q.F7VF 11&0 ON" f TOWN OF SOUTHOLD
UG LPTANK
APPROVED BY -
>
OARD OF 1 RUSTEES \ A o a
AWN OF SOUTHOLD , i i OOT>t 7T'A :
Pau NOV
_ -
UT
20
r -s
7 6
' � I
POLE —
T9
pp,D
RE R
8AY SHO
PREPARED BY INTER-SCIENCE RESEARCH ASSOCIATE!
:)n survey prepared by Peconic Surveyors: 10/24/2018 DATE PREPARED: 3/20/2011
ils per Marshal Paetzel Landscape Architecture: 9/21/2020
?d to NAVD 1988 Datum. REVISED WITH PATH DETAILS: 7/22/201 _
n by S.L. Maresca Associates. REVISED SITE PLAN: 10/21/202(
GENERAC
Protector OS PROTECTOR® QS SERIES
Series Standby Generators
Liquid-Cooled Gaseous Engine
INCLUDES: Standby Power Rating
0 Two-Line LCD Multilingual Digital Evolution'"" Model RG022 (Aluminum - Bisque) -22 kW 60 Hz
Controller(English/Spanish/French/ Model RG027 (Aluminum - Bisque) -27 kW 60 Hz
Portuguese)with external viewing window for el RG umi - - W 60 Hz
easy indication of generator status and odel RG038 (Aluminum - Bisque) -38 kW 60 Hz
breaker position.
0 True PowerT"" Electrical Technology
• Isochronous Electronic Governor Ii
• Sound Attenuated Enclosure -
Closed Coolant Recovery System
• Smart Battery Charger x
• UV/Ozone Resistant Hoses _ -
• --I%Voltage Regulation -
• Natural Gas or LP Operation
• 5 Year Limited Warranty
• UL 2200 Listed
• SwRi® listed (NFPA37, clause 4.1.4.1.2) CST US QUI
Generator can be installed a minimum 18"
mmwc•.a mmy�n
distance from combustible wall* Meets EPA Emission Regulations
22&27 kW are CA/MA emissions compliant
*Only if located away from doors,windows,and fresh air intakes, 32&38 kW not for sale in CA/MA
and unless otherwise directed by local codes.Please review
install guide for more details.
FEATURES
O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE
GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't REGULATION.This state-of-the-art power maximizing regulation system is
stop there. Total commitment to component testing, reliability testing, standard on all Generac models.It provides optimized FAST RESPONSE to
environmental testing, destruction and life testing, plus testing to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY
applicable CSA, NEMA, EGSA, and other standards, allows you to choose by electronically torque-matching the surge loads to the engine. Digital
GENERAC POWER SYSTEMS with the confidence that these systems will voltage regulation at±1%.
provide superior performance.
O TEST CRITERIA: O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
✓PROTOTYPE TESTED ✓NEMA MG1-22 EVALUATION network provides parts and service know-how for the entire unit, from the
✓SYSTEM TORSIONAL TESTED ✓MOTOR STARTING ABILITY engine to the smallest electronic component.
O GENERAC TRANSFER SNITCHES. Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is the GENERAC product line is offered with its own transfer
systems and controls for total system compatibility.
GENERAC®
GENERAC®
22 • 27 • 32 • 38 application & engineering data
GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS: 22,27,32 &38 kW
Type Synchronous Make Generac
Rotor Insulation Class H(22&27 kW)or Model In-line
F(32&38 kW) 4
Cylinders
Stator Insulation Class H
Displacement(Liters) 2.4
Telephone Interference Factor(TIF) <50
Bore(in/mm) l 3.41/86.5
Alternator Output Leads 1-Phase 4 wire
Stroke(in/mm) 3.94/100
Alternator Output Leads 3-Phase 6 wire
Compression Ratio 9.5:1
Bearings Sealed Ball
Naturally Aspirated(22&27 kW)
Coupling Flexible Disc or
Intake Air System Turbocharged/Aftercoohed
Excitation System Direct (32&38 kW)
VOLTAGE REGULATION Litter Type Hydraulic
Type Electronic
Sensing Single Phase ENGINE LUBRICATION SYSTEM
Oil Pump Type Gear
Regulation +1%
Oil Filter Type Full flow spin-on cartridge
GOVERNOR SPECIFICATIONS Crankcase Capacity(qVI) 4/3.8(22,27,32&38 kW)
Type Electronic
ENGINE COOLING SYSTEM
Frequency Regulation Isochronous
Type Closed
Steady State Regulation ±0.25%
Water Pump Belt driven
ELECTRICAL SYSTEM Fan Speed(rpm) 1980-22&27 kW
1500-32&38 kW
Battery Charge Alternator 12 Volt 30 Amp FDiameter 18.1/459.7(22&27 kW)or
Fan ameer(in/mm)
Static Battery Charger 2.5 Amp 22/558.8(32&38 kW)
Recommended Battery(battery not included) Group 26(22,27,32&38 kW) Fan Mode Pusher(22&27 kW)or
System Voltage 12 Volts
Puller(32&38 kW)
FUEL SYSTEM
GENERATOR FEATURES Fuel Type Natural gas,propane vapor
Revolving field heavy duty generator
Directly connected to the engine Carburetor Down Draft
Operating temperature rise 120°C above a 40°C ambient Secondary Fuel Regulator Standard
Class H insulation is NEMA rated
Class F insulation is NEMA rated Fuel Shut Off Solenoid Standard
All models fully prototyped tested Operating Fuel Pressure 5-14"water column/9-26 mm HG
LP Fuel Pressure 11-14"Water Column
ENCLOSURE FEATURES NG Fuel Pressure 5-14"Water Column
Aluminum weather protective Ensures protection against mother nature.
enclosure Electrostatically applied textured epoxy paint for added du-
rability.
Enclosed critical grade muf- Quiet, critical grade muffler is mounted inside the unit to
flier prevent injuries.
Small,compact,attractive Makes for an easy,eye appealing installation.
SAE Sound attenuated enclosure ensures quiet operation.
(All ratings in accordance with BS5514,IS03046,ISO8528,SAE J1349 and DIN6271)
GENERAC®
22 • 27 • 32 • 38 operating data
0
GENERATOR OUTPUT VOLTAGEAW-60 Hz
W LPG Amp LPG kW Nat.Gas Amp Nat.Gas CB Size(Both)
120/240 V,10,1.0 pf 22 92 22 92 100
RG022 120/208 V.30,0.8 pf 22 76 22 76 80
120/240 V.30,0.8 pf 22 66 22 66 80
120/240 V,10,1.0 pf 27 113 25 104 125
RG027 120/208 V,30,0.8 pf 27 94 25 87 100
120/240 V,30,0.8 pf 27 81 25 75 90
120/240 V,10,1.0 pf 32 133 32 133 150
120/208 V,30,0.8 pf 32 111 32 111 125
RG032
120/240 V,30,0.8 pf 32 96 32 96 100
277/480 V,30,0.8 pf 32 48 32 48 60
120/240 V,10,1.0 pf 38 158 38 158 175
120/208 V,30,0.8 pf 38 132 38 132 150
RG038
120/240 V,30,0.8 pf 38 114 38 114 125
277/480 V,30,0.8 pf 38 57 38 57 60
SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION
Voltage Dip @<.4 pf Natural Gas Propane
15% 30% (ft3/hr) (m3/hr) (gal/hr) (ft3/hr) (1/hr)
120/240 V,10 55 135 Exercise cycle 42 1.2 0.44 16 1.7
RG022 120/208 V,30 40 92 25%of rated load 100 2.8 1.1 40 4.2
120/240 V,30 35 80 RG022 50%of rated load 190 5.4 2.1 75 7.8
120/240 V,10 62 170 75%of rated load 255 7.2 2.8 101 10.5
RG027 120/208 V,30 70 120 100%of rated load 316 9 3.4 125 13
120/240 V,30 61 103 Exercise cycle 42 1.2 0.44 16 1.7
120/240 V,10 75 180 25%of rated load 108 3.1 1.2 43 4.5
120/208 V,30 87 210 RG027 50%of rated load 197 5.6 2.1 78 8.1
RG032
120/240 V,30 75 182 75%of rated load 287 8.2 3.1 114 11.8
277/480 V,30 36 87 100%of rated load 359 10.2 3.9 143 14.8
120/240 V,10 75 180 Exercise cycle 79 2.2 0.8 30 3.2
120/208 V,30 87 1 210 25%of rated load 144' 4.1 1.7 60 6.3
RG038
120/240 V,30 75 182 RG032 50%of rated load 226 6.4 2.7 97 10.3
277/480 V,30 36 87 75%of rated load 298 6.4 3.7 132 13.9
100%of rated load 375 10.6 4.6 166 17.5
Note:Fuel pipe must be sized for full load. Exercise cycle 83 2.3 0.9 31 3.2
For Btu content,multiply ft3/hr x 2520(LP)or ft3/hr x 1000(NG) 25%of rated load 162 4.6 1.7 62 6.6
RG038 50%of rated load 255 7.2 2.9 103 10.8
For megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG)
75%of rated load 345 9.8 4 142 15
Refer to"Emissions Data Sheets"for maximum fuel flow for EPA and SCAQMD
permitting purposes. 1 100%of rated load 437 12.4 5.2 185 19
STANDBY RATING:Standby ratings apply to installations served by a reliable utility source.The standby rating is applicable to varying loads for the duration of a power outage.
There is no overload capability for this rating.Ratings are in accordance with ISO-3046-1.Design and specifications are subject to change without notice.
GENERAC®
22 • 27 • 32 • 38 operating data
3
ENGINE COOLING
22 kW 27 kW 32&38 kW
Air flow(inlet air including alternator and combustion air in cfm/cmm) 2400/68 2400/68 2200/62.3
System coolant capacity(gal/liters) 2.5/9.5 2.5/9.5 2.5/9.5
Heat rejection to coolant(BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 145,000/153
Maximum operation air temperature on radiator(*C/°F) 60/150
Maximum ambient temperature(°CPP 50/140
COMBUSTION REQUIREMENTS
Flow at rated power(cfm/cmm) 1 68/1.9 68/1.9 106/3
SOUND EMISSIONS
Sound output in d6(A)at 23 ft(7 m)with generator in exercise made* 61 61 58
Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load* 70 70 64
EXHAUST
Exhaust flow at rated output(cfm/cmm) 165/4.7 180/5.1 1 300/8.5
Exhaust temperature at muffler outlet(°Cff) 482/900 538/1000 579/1075
ENGINE PARAMETERS
Rated Synchronous rpm 1800
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
Temperature Deration....................................................................................................................3%for every 10°C above 25°C or 1.65%for every 10 OF above 77 OF
Altitude Deration(22&27 kW)......................................................................................................1%for every 100 m above 183 m or 3%for every 1000 It above 600 It
Altitude Deration(32&38 kW)...................................................................................................1%for every 100 m above 915 m or 3%for every 1000 ft above 3000 It
CONTROLLER FEATURES
Two-Line Plain Text LCD Display............................................................................................................................................Simple user interface for ease of operation.
Mode Switch: Auto.....................................................................................................................................................Automatic Start on Utility failure.7 day exerciser
Off.................................................................................................................................Stops unit.Power is removed.Control and charger still operate.
Manual.................................................................................................Start with starter control,unit stays on.If utility fails,transfer to load takes place.
Programmable start delay between 10-30 seconds..........................................................................................................................................................10 sec standard
Engine Start Sequence.................................................................:.............................................................Cyclic cranking:16 sec on,7 rest(90 sec maximum duration)
EngineWarm-up...............................................................................................................................-..........................................................................................-5 sec
EngineCool-Down..........................................................................................................................................................................................................................1 min
Starter Lock-out..........................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped.
SmartBattery Charger.................................................................................................................................................................................................................Standard
Automatic Voltage Regulation with Over and Under Voltage Protection........................................................................................................................................Standard
AutomaticLow Oil Pressure Shutdown........................................................................................................................................................................................Standard
OverspeedShutdown.......................................................................................................................................................................................................Standard,72 Hz
HighTemperature Shutdown...................................................................................................................................................................................................... Standard
OvercrankProtection..................................................................................................................................................................................................................Standard
SafetyFused..............................................................................................................................................................................................................................Standard
Failureto Transfer Protection......................................................................................................................................................................................................Standard
LowBattery Protection................................................................................................................................................................................................................Standard
50 Event Run Log.......................................................................................................................................................................................................................Standard
FutureSet Capable Exerciser..................................................................................................................................................................................................... Standard
IncorrectWiring Protection........................................................................................................................................................................................................ Standard
InternalFault Protection..............................................................................................................................................................................................................Standard
CommonExternal Fault Capability..............................................................................................................................................................................................Standard
GovernorFailure Protection....................................................................................................................................................................................................... Standard
- GENERAC®
22 • 27 • 32 • 38 available accessories _
10
- o
froduc3 Description,
.Model #
eGenerac's Mobile Link allows you to check the status of your generator from
Mobile Link®4G LTE ! anywhere that you have access to an Internet connection from a PC or with
G0071690any smart device.You will even be notified when a change in the generator's
Cellular Accessory
status occurs via e-mail or text message.Note:Harness Adapter Kit required.
Available in the U.S.only.
- -------------- ---------- Kit, Adapter Mobile------------------
G006478-0 ! Link L/C (Required
The Harness Adapter Kit is required to make liquid-cooled units compatible
for QT and RG Series) ! with Mobile Link®.
G005630-1 -22, 27, 32&38 If the temperature regularly falls below 32 OF(0°C), install a cold weather kit
'
kW Cold Weather Kit to maintain optimal battery temperature. Kit consists of battery warmer with
1 thermostat built into the wrap.
G005616-0-22, 27, 32&38 Extreme Cold Recommended where the temperature regularly falls below 32 OF(0°C)for
kW Weather Kit extended periods of time. For liquid cooled units only.
G005051-0 1 Base Plug Kit I Add base plugs to the base of the generator to keep out debris,
If the generator enclosure is scratched or damaged,it is importantto touch-up
G005703-0- Bisque Paint Kit the paint to protect from future corrosion.The paint kit includes the necessary i
paint to properly maintain or touch-up a generator enclosure.
The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware
G005656-0-22&27 kW Scheduled ; necessary to perform complete maintenance on Generac liquid-cooled
G005984-0-32&38 kW Maintenance Kit generators.
- ------------
G006664-0 Local Wireless Completely wireless and battery powered,Generac's wireless remote monitor
Monitor provides you with instant status information without ever leaving the house.
Wireless Remote Recommended for use with the Wireless Remote on units up to 60 kW,
G006665-0 Extension Harness i required for use on units 70 kW or greater.
i ---------- - ----- - -- ----- ---------------------------------- -- --- --- ----- -- -
Smart Management Modules are used in conjunction with the Automatic
Smart Management Transfer Switch to increase its power management capabilities. It provides
G006873-0 ! Module (50 Amps) additional power management flexibility not found in any other power
i
management system.
---------- ----------
E-stop toggle switch E-stop allows for immediate fuel shutoff and generator shutdown in the event
G007993-0 ; for residential installs ! of an emergency.
to NEC2017
I E-Stop resettable
G006510-0 switch for commer- E-stop allows for immediate fuel shutoff and generator shutdown in the event
cial installs to of an emergency.
NEC2020
The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the
Wi-Fi LP Fuel Level
connected LP fuel tank.Monitoring the LP tank's fuel level is an important step
G007005-0 ! in making sure your generator is ready to run during an unexpected power
Monitor failure.Status alerts are available through a free application to notify when your
LP tank is in need of a refill.