Loading...
HomeMy WebLinkAbout48816-Z �os�FFoc,�CpGy{ Town of Southold 16/4/2023 a P.O.Box 1179 53095 Main Rd Southold,New York 11971 01 CERTIFICATE OF OCCUPANCY No: 44642 Date: 10/4/2023 THIS CERTIFIES that the building ALTERATION Location of Property: 9870 Route 25, Laurel SCTM#: 473889 Sec/Block/Lot: 143.-2-30.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/28/2022 pursuant to which Building Permit No. 48816 dated 1/30/2023 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: interior alterations to existing retail store as applied for. The certificate is issued to SCP 2005-C21-051 LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48816 9/29/2023 PLUMBERS CERTIFICATION DATED A o 'z d gnature �o�S�FFQi�co TOWN OF SOUTHOLD BUILDING DEPARTMENT cm TOWN CLERK'S OFFICE oy • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48816 Date: 1/30/2023 Permission is hereby granted to: SCP 2005-C21-051 LLC c/o CVS Corporation One CVS Dr Woonsocket, RI 02895 To: Construct interior alterations to existing retail store as applied for. At premises located at: 9870 Route 25, Laurel SCTM #473889 Sec/Block/Lot# 143.-2-30.2 Pursuant to application dated 12/28/2022 and approved by the Building Inspector. To expire on 7/31/2024. Fees: COMMERCIAL ADDITION/ALTERATION $1,419.60 CO-COMMERCIAL $50.00 Total: $1,469.60 Building Inspector OE SO!/j�Ql 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(D-town.southold.ny.us Southold,NY 11971-0959 Q`yCOUffm�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: SCP 2005-C21-051 LLC Address: 9870 Route 25 city:Laurel st: NY zip: 11948 Building Permit* 48816 Section: 143 Block: 2 Lot: 30.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: O'Reilly Electric License No: 2250ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 12 Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 2X4 LED (1) Notes: Added a Light & Moved Some Outlets Inspector Signature: Date: September 29, 2023 S.Devlin-Cert Electrical Compliance Form SO(/lh°� # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATIOWCAULKING [ ] FRAMING /STRAPPING [ (FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]' RENTAL REMARKS: 6RAIL- Apo 17 1'n DATE I NSPECTORot SOUTyo - * # TOWN LO SOU HOLD BUILDING DEPT. coom,��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ IRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REM RKS: �C CO c/.-nos /i DATE l �� INSPECTOR �/ JS q4f so # TOWN OF SOUTHOLD BUILDING DEPT. �ycourm, ' 631.765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) [ ] CODE VIOLATION ] -PRE C/O [ ] RENTAL REMARKS: NWS DATE `L Z3 INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS CSS � FOUNDATION (1ST) " ------------------------------------- FOUNDATION (2ND) -� 8 ROUGH FRAMING& N �3 1 PLUMBING `r r� INSULATION PER N. Y. STATE ENERGY CODE IA Wlloiluk re MOLAWA FINAL ADDITIONAL COKEN OS S2 � o :�E 0 7 i Vic- ' qc m V� �o v � IP b N x x r� '®� TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPUCATION FORBUILDING PERMIT For Office Use Only PERMIT N0. oft- Building Inspector: DEC 2 8 9n77UD Applications and forms must be filled out in their entirety. Incomplete BUILDINGDBYT. applications will not be accepted. Where the Applicant is not the owner,an T0WN'0FS0IR4OCD Owner's Authorization form(Page 2)shall be completed. Date: la OWNER(S)OF PROPERTY: Name:SCP 2005-C21-051 LLC SCTM# 1000- p 4 1. 7 2 -_30 .Z Project Address:9870 Main Rd, Mattituck, NY 11952 Phone#:401-479-6522 Email:Michael.DeCarvalho@cvshealth.com Mailing Address:One CVS Dr, Woonsocket, RI 02895 CONTACT PERSON: Name:State Permits, Inc. - Kelly Ley Mailing Address:319 Elaines Ct., Dodgeville, WI 53533 Phone#:608-407-9086 Email:kelly@permit.com DESIGN PROFESSIONAL INFORMATION: Name:SBLM Architects Mailing Address:545 West 45th St., New York, NY 10036 Phone#:212-995-5600Ercall:tlopes@sbim.com CONTRACTOR INFORMATION: Name:TBD Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ \30 , 000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ©No 1 PROPERTY INF RMATI N '<> RO 0 O Existing use of property:Comm Retail/Pharmacy Intended use of property:Comm Retail/Pharmacy "Zone%or use district in which premises is situated: Are there any covenants and restrictions with respect to B1. this property? ❑Yes ANo IF YES, PROVIDE A COPY. ❑ Check:Box°After:Reading: The owner/contractor/design professional is responsible for all drainage and storm water'issues as provided Y Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to.the Building Zone. Ordinance of the.Town of Southold,Suffolk,County,New York andbther applicable'Laws,Ordinances or.Regulations;for the construction of b'uildings,, ,additions;alterations or for,removal or demolition as herein described:The appli6ant agrees,to compiy.with-all applicable laws,ordinances,building code;: ,housing code and regulations and to admit authorized inspectors onpremises and�in buildingls)for necessary inspections.,False statements'made herein are;`.:: 'punishable as a cliss;A misdemeanor pursuant to Section 210 45 of the,New York State,0enal Law.'. " Application Submitted By(print name):Kel ly Ley @Authorized Agent ❑Owner Signature of Applicant:---- ���; , _ Date: STATE OF NEWTORK)— SS: COUNTY OF 'raw a ) z: ��1 �=" being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Ij (Contract r, gen ,Corporate Officer,etc.) of said owner or owners,and is duly authorized to pe orm or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and b5117 -f and that the work will be performed in the manner set forth in the application file therewith. %``��.\��HELll,'�,,� i Sworn before me this ' t%0TgRy':2 l(�day of DeCeyinbe..r ,20 `A =e a A ~' = o ary Public�y ,., SI LIG PROPERTY OWNER AUTHORIZATION ����r�t I u t►��� (Where the applicant is not the owner) I' Michael DeCarvalho on behalf of SCP 2005 C21 051 LLC rung at O n e CVS Drive Woonsocket, RI 02895 do hereby authorize State Permits, Inc. - Kelly Ley to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Michael DeCarvalho Print Owner's Name 2 :TBUILDINGDEPARTMENT- Electricallnspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ` . , rogerrCa southoldtownny.gov sea ndsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: J3 a Company Name: o&J4 ��- Electrician's Name: License No.: 'a&S-0 Elec. email: Elec. Phone No: 6-14- a5--723LPA request an em it copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: C V Address: Cross Street: Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTIO OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES NO [:]Rough Ina 2� ❑ Final Do you need a Temp Certificate?: F] YES NO Issued On Temp Information: (All information required) Service Size Ill Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 M H Frame Pole Work done on Service? [J1_0N Additional Information: PAYMENT DUE WITH APPLICATION rz BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roc .soLltholdtownny.gov seand c�southoldtownny.g_ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: f,3a Company Name: e' )I Electrician's Name: License No.: agt370 Elec. email: O��il e-�e�`�/',`�®® sJlin& Elec. Phone No: 51 ( - 3 request an em it copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: C V Address: `�'g („ �- r / % _Q, Cross Street: Phone No.: Bldg.Permit #: -/ email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): _Ln��'u 11e bu�le r 1 F Chrckv� e,— Square Footage: Circle All That Apply: VI yq Is job read for Inspection?: YES9NO Rou(h In ' Final J Y p ❑ ❑ g ❑ Do you need a Temp Certificate?: ❑ YES NO Issued On Ternp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: —____A # Meters Old Meter# ®New Service[]Fire.Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Uhderground Laterals n 1 2 [-] H Frame F-1 Pole VVork done on Service? Y N Additional Information: PAYMENT DUE WiTH APPLICATION Rp LQ " -a,eF`,�'� Address PERMIT N Switches Outlets GFI's Surface Sconces HH'S r UC Lts IL.� Fans Fridge HW Exhaust Oven WAD DW Mini Smokes Micro Generator -arbon Cooktop Transfer -ombo aC AH Hood Service Amps Have Usec ,pecial :omments Letter of Transmittal Project#: 947564 Date: 12/27/2022 3:15pm PERMIT.COM Store: CVS#: 03105 State Permits Inc. Address: 9870 MAIN ROAD 319 Elaines Court-Dodgeville,WI 53533 Mattituck,NY,11952 (608) 999-9998-www.permit.com From: To: Kelly Ley Building Dept-NY 319 Elaines Court Southold Building Dept Dodgeville Wl 53533 Town Hall Annex Building 608-407-9086-kelly@permit.com Southold, NY 11971 (631)765-1802 Transmitting Via: Items: 1 BPA with org wet SN 4 SS sets(2 Wet SS 2 Copies) These Are Transmitted: Plan Check Number:0 Remarks: Hello, Enclosed is a commercial submission for a proposed renovation. Please let us know if there is anything further you require to process and/or complete the review. Thank you, y DEC 2 8 2022 g:GDEQ- Signature: Kelly Ley-608-407-9086-kelly@permit.com 415-PERMITS•www.permit.com Pontino, Susan From: Kelly Ley <kelly@permit.com> Sent: Tuesday,January 31, 2023 12:44 PM To: Pontino, Susan Cc: Vinny Chiarelli;john riportella Subject: Permit#48816 - CVS 03105 CS 165265 - 9870 Main Rd/Route 25, Mattituck, NY(Town of Southold) Hello Susan, The awarded GC for the above mentioned project is: Custom Commercial Construction 76 Brook St Bay Shore,NY 11706 631-665-3232 They will work on getting you their Suffolk County license and insurances. Thank you, Kelly Ley kelly@permit.com; 608/407-9086 State Permits,Inc. 319 Elaines Ct,Dodgeville,WI 53533 ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 1 Mejia, Evelin From: Mejia, Evelin Sent: Wednesday, August 16, 2023 12:06 PM To: 'kelly@permit.com' Subject: Open items on BP#48816 Attachments: ####48816tix_20230816115928.pdf Good afternoon, An Electrical Certificate of Compliance and an inspection from the Fire Marshall are required in order to close out Permit#48816 for the property at: 9870 Route 25, Laurel Please mail/bring in an Electrical Inspection Form along with the fee and call to schedule an inspection with the Fire Marshall. Attached is a copy of the Final Inspection Ticket. Thank you Evelin Mejia Town Of Southold Building Department Annex Building - 54375 Main Road Southold, NY 11971 (631)765-1802 1 DATE(MMIDDIYYYY) A�" CERTIFICATE OF LIABILITY INSURANCE 02/15/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Ashlea Tarkazikis NAME: PF Northeast Brokerage Inc PHONE (845)223-8107 FAX No: (845)227-8816 AIC No Ext 1035 Route 82 E-MAIL ADDRESS: atarkazikis@pfnortheast.com INSURER(S)AFFORDING COVERAGE NAIC# Hopewell Junction NY 12533 INSURERA: Continental Casualty Company 20443 INSURED INSURER B: Continental Insurance CO 35289 Custom Commercial Construction Corp INSURER C: 76 Brook Street INSURER D INSURER E: ' Bay Shore NY 11706 INSURER F; COVERAGES CERTIFICATE NUMBER: CL229281419,0 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MMIDDY� MM/DDS LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 IIA AGE TO RENTED CLAIMS-MADE ®OCCUR PREM SES Ea occurrence) $ 100,000 3 X Contractual Liability MED EXP(Any one person) $ 15,000 A 6071973039 09/27/2022 09/27/2023pERsoNAL&AOVINJURY $ 1,000,000 1 GEN'LAGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY [gPRO ❑LOC PRODUCTS-COMP/OPAGG $ 2,000,000 JECT OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident 'X ANYAUTO BODILY I NJURY(Per person) $ B OWNED SCHEDULED BUA6079102663 09/27/2022 09/27/2023 BODILY INJURY(Per accident) $ AUTOSONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident $ — UMBRELLA LIAB 5,000,000 X,i X OCCUR EACH OCCURRENCE $ B EXCESS LIAB CLAIMS-MADE 6071973025 09/27/2022 09/27/2023 AGGREGATE is 5,000,000 ;I DED I X RETENTION$ 10,000 .$ WORKERS COMPENSATION ! I PER OTH- AND EMPLOYERS'LIABILITY �,/N" STATUTE I ER ANY PROPRIETOR/PARTNER/EXECUTIVENIA ;E.L E:ACHACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) ❑ E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be e3ached if more space is required) Provided it is required by written contract,the following are named as additional insured as respects general liability with regard to work being performed by the insured under form CNA75079XX(10-16),to the extent provided therein:Town of Southold CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 54375 NY 25 AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2015 ACORD CORPORATION. All rights reserved. ` ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD Yo K Com Workers' STATE CERTIFICATE OF INSURANCE COVERAGE pensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured CUSTOM COMMERCIAL CONSTRUCTION CORP. 631-665-3232 ATTN: PATRICIA RIPORTELLA 76 BROOK STREET BAY SHORE,NY 11706 1 c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 112256791 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 NY 25 3b. Policy Number of Entity Listed in Box"l a" Southold, NY 11971 DBL433962 3c.Policy effective period i 01/01/2023 to 12/31/2023 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. F] B.Disability benefits only. n C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Signed 2/15/2023 By Val, 4f (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if sox 48,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers' Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) Additional Instructions for Form D13-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1 a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law. The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage (Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c, whichever is earlier. This Certificate is issued as a matter of information only and confers no rights upon the certificate holder. This Certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating rgny liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to ,any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into .ny contract for or in connection with any work involving the employment of employees in employment as defined in this ,ajlicla and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into ,r:ny such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that t11e payment of disability benefits and after January first, two thousand eighteen, the payment of family leave benefits for ~-ll employees has been secured as provided by this article. l k)�3-12R.1 verse YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) I b. Business Telephone Number of Insured (631)665-3232 Custom Commercial Construction Corp 76 Brook Street lc.NYS Unemployment Insurance Employer Registration Number of Bay Shore,NY 11706 Insured Work Location of Insured(Only required if coverage is specifically limited to ld. Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,aWrap-Up Policy) Number 11-2256791 t` Name of Insurance Carrier National Fire Insurance Company of Hartford 2.Name and Address of Entity Requesting Proof of Coverage 3a Town of Southold 54375 NY 25 Southold,NY 11971 3b. Policy Number of Entity Listed in Box"la" 6078964704 3c.Policy effective period 7/26/2022 to 07/26/2023 3d.The Proprietor,Partners or Executive Officers are Cincluded.(Only check box if all partners/officers included) E] all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"la"for workers'compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2'. Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend,extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Joseph W.Pires (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 2/15/23 (Signature) (Date) Title:President Telephone Number of authorized representative or licensed agent of insurance carrier: (845 223-8107 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-15) www.wcb.ny.gov Workers' Compensation Law Section 57. Restriction on issue of permits and the entering into contracts unless compensation is secured. 1. The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. C-105.2(9-15) REVERSE VW% MIFF TM ' phalrpm -n- cy DEC2891"19 tq D aUir_U1NU DEPT TOWNI OP gnMOLD 9870 MAIN RD � N Y 11952 RESET MATTITUCK , STORE DUMBER: 03105 W 9870 MAIN ROAD MATTITUCK, NY 11952 m PROJECT TYPE: (72) RESET DRAWING INDEX TEAM MEMBERS BUILDING CODE & STANDARDS LOCATION MAP N ARCHITECT: SBLM THOMAS LOPES/ The building shall be in compliance with the following: CS PROJECT NUMBER: 165265 C G1 COVER SHEET 545 WEST 45TH STREET JUSTIN CASTRO ® G4 CODE INFORMATION & ACCESSIBLE CODE COMPLIANCE FOURTH FLOOR 2020 Building Code of New York State TEL: (212) 995-5600 2020 Fire Code of New York State - ARCHITECT OF RECORD FIXTURE PLAN NEW YORK CITY, NY 10036 FAX: (212) 675-4228 2020 Energy Conservation Construction Code of New York State 4�- F-1 MERCHANDISE PLAN 2020 Mechanical Code of New York State 2020 Plumbing Code of New York StateILI ��rcx. & Tppr ARCHITECTURAL ELECTRICAL HENDERSON CONSULTING ENGINEERS KYLE OVERCASH 2020 Fuel Gas Code of New York State ELeg,o„aae. 13 AD1 DEMOLITION FLOOR PLAN ENGINEER: 8345 LENEXA DRIVE TEL• (913) 742-5000 2020 Existing Building Code of New York State °� 13 AD2 DEMOLITION REFLECTED CEILING PLAN SUITE 300 2010 ADA Standards for Accessible Design w/ 2009 ANSI 117.1 T�Q 13 Al OVERALL FLOOR PLAN LENEXA, KS 66214 SBLM 13 A2 REFLECTED CEILING PLAN 01e1Pe. 545 West 45th Street 4th Floor f3 A4 FINISH PLAN "SPha""a`'' New York, NY 10036 A5 INTERIOR ELEVATIONS �.a• ® 0 A6 ACCESSIBLE DETAILS MECH./PLUMB. HENDERSON CONSULTING ENGINEERS KYLE OVERCASH GENERAL NOTE TO PLAN EXAMINER: �� T: 212.995.5600 F: 212.675.4228 NO CHANGE TO EXISTING BUILDING USE. ONE TOILET ROOM TO REMAIN R' www.sblm.com 13 A7 SCHEDULES AND DETAILS ENGINEER: 8345 LENEXA DRIVE TEL: (913) 742-5000OPEN AT ALL TIMES DURING CONSTRUCTION AS REQUIRED ON APPLICATION SUITE 300 MECHANICAL LENEXA, KS 66214 TOTAL BUILDING SQ. FT.: 14,249 SF �sbry CONSULTANT ENGINEER; m M1 MECHANICAL SPECIFICATIONS 4 M1.1 MECHANICAL SPECIFICATIONS EXISTING PROPOSED MAP DATA 0 2022 MAPOUEST 13 M2 MECHANICAL PLAN, SCHEDULES & DETAILS CVS SENIOR CVS/PHARMACY, INC. Zachary Mannino CURRENT OCCUPANT CVS/PHARMACY CVS/PHARMACY (No CHANGE) SITE LOCATION HENDERSON ELECTRICAL PROJECT 518 W SOUTHERN AVE, SOUTH Zachary.Mannino0cwhealth.com TYPE OF BUSINESS RETAIL/PHARMACY RETAIL/PHARMACY (NO CHANGE) W ENGINEERS MANAGER: WILLIAMSPORT, PA 17702 CELL.(570) 560-3857 ® E1 ELECTRICAL SPECIFICATIONS TYPE OF CONSTRUCTION IIB IIB (NO CHANGE) SITE KEY PLAN N.T.S. 8345 LENEXA KIS 66SUI 214TE 300 E1.1 ELECTRICAL SPECIFICATIONS BUILDING USE GROUP MERCANTILE MERCANTILE (NO CHANGE) TEL 913.742.5000 FAX 913.742.5001 ® ED1 LIGHTING DEMOLITION PLAN In ED2 'OWER DEMOLITION PLANS HEIGHT/N0. OF STORIES 1 STORY 1 STORY (NO CHANGE) WWW.HENDERSONENGINEERS.COM In E2 SYMBOLS & RISER DIAGRAM TENANT: CVS/PHARMACY, INC. TEL: (401) 765-1500 FULLY SPRINKLERED (Y/N) Y Y (NO CHANGE) ® E3 LIGHTING PLAN 1 CVS DRIVE 10 E4 POWER PLAN WOONSOCKET, RI 02895 13 EC1 ELECTRICAL ENERGY COMPLIANCE R 9 CONSULTANT•, PROJECT DESCRIPTION: LANDLORD: MASON & MASON, P.C. WI"IWAM M. MASON INTERIOR RENOVAT0 OF AN EXISTING RETAIL SPACE. MODIFICATION OF \\\ 394 Old Country Road 516-739-3090 WAITING AREA, BATHROOMS, BREAK ROOM, OFFICE, PHARMACY, PHOTO LAB APPFIDVEDS NOTED Garden City, NY 11530 AND CHECKOUT AREAS, INCLUDING REPLACEMENT OF MILLWORK AND � • , '�?; D.P•e ��, � FINISHES. - `�_L0,29, U® � Y OCCUPANCY Oil s�.. ASSOCIATED ELECTRICAL AND MECHANICAL WORK AND ADA IMPROVEMENTS. NOTIFY BUILDING DEPART ENTAT USE IS Ui�L���� VL 5'(0R :: NO CHANGE TO USE, EGRESS OR OCCUPANCY. :GVH:::::: 631-765.1802 BAMTOdPMFORTNE �' CONTRACTOR: T.B.D. — CONTRACT NOT YET AWARDED NO CHANGE TO PLUMBING FIXTURE COUNT. 3'W.� ..... :::: ^^ FOLLOWING INSPECTIONS: WITHOUT CERTIFICATE .:.. ::.... NO SITE OR EXTERIOR IMPROVEMENTS. SEAL 1. FOUNDATION-TWO REQUIRED OF %PUPANC ... ;� r FOR POURED CONCRETE 2. ROUGH-FRAMING&PIUM8INC0 -. . SYMBOLS F_ ARC 3. INSULOITION 4. FINAL-CONSTRUCTION MUSX' f � PS MICHgF�< BE COMPLETE FOR C.O. �O 0 �0 'A ALL CONSTRUCTION SHALL MEET TME A CENTERLINE OF _ _ xx ENLARGED PLAN �� N � AEOUIREME NTSOFTHECODESOFNEW COMIPLY WITH ALL CODES OFF COLLMN i xxx DETAIL MARK �r Wall,YORK STATE NOT RESPONS BLE FOn MIGNORCONSTRUCTONERRORS MEW YORK STATE & TOWN CODES AS REQUIRED/AND CONDITIONS OF — — SOUTHOLDTO+'NZBASECTION MARK sT 0409 SOUTHUTOMPLANN!"<GBOI 3 xxx ELEVATION MARK xx 'SIM' — SIMILAR r-IRE: INSPECTION � SOUTHOLDTOM TRUSTEES xxx 'OH' — OPPOSITE RECiUIIRED BEFORE NY.S.DEC HAND 'PE.I�Ii�IG REVISIONS: DATE: ISSUE/REVISION: 12-16-2022 BID/PERMIT SET AREA OF WORK: _ ABBREVIATIONSUSEDRONATHE DRAWINGS)RE NOT NECESSARILY A C (CONTINUED) E (CONTINUED) H (CONTINUED) M P (CONTINUED) S (CONTINUED) V AB ANCHOR BOLT CONT CONTINUOUS, CONTINUATION EXP EXPANSION HVU HEATING AND VENTILATING JNIT MAX MAXIMUM PDU POWER DISTRIBUTION UNIT SHT SHEET V VOLT A/C AIR CONDITIONING COORD COORDINATE EXIST EXISTING HVY HEAVY MDP MAIN DISTRIBUTION PANEL PERP PERPENDICULAR SIM SIMILAR VA VOLT-AMPERE AC ALTERNATING CURRENT CR CONDENSATE RETURN EXT EXTERNAL, EXTERIOR MECH MECHANICAL PH PHASE SHT MTL SHEET METAL VERT VERTICAL ACIAMERICAN CONCRETE INSTITUTE CJ CONTROL JOINT EW EACH WAY MEZZ MEZZANINE PT PAINT SPEC SPECIFICATION VIF VERIFY IN FIELD ACCESS ACCESSORIES CTR CENTER EWC ELECTRIC WATER COOLERI MFR MANUFACTURER PL PLATE SQ SQUARE VRC VERTICAL RECIPROCATING ADA AMERICANS WITH DISABILITIES CV CHECK VALVE MH MANHOLE, METAL HALIDE PLBG PLUMBING SS STAINLESS STEEL, SANITARY CONVEYOR ACT CW COLD WATER ID INSIDE DIAMETER MIN MINIMUM PNL PANEL SEWER VTR VENT THROUGH ROOF ADD'L ADDITIONAL IE INVERT ELEVATION MLO MAIN LUGS ONLY PIV POST INDICATOR VALVE STC SOUND TRANSMISSION CLASS ADJ ADJUSTABLE INT INTERIOR MO MASONRY OPENING PSF POUNDS PER SQUARE FOOT STD STANDARD AFF ABOVE FINISHED FLOOR INTER INTERMEDIATE MSB MAIN SWITCHBOARD PVC POLYVINYL CHLORIDE STL STEEL AFP ABOVE FINISHED PLATFORM D FA FIRE ALARM IN INCH, INCHES MTD MOUNTED PWD PLYWOOD STIFF STIFFENER ALUM ALUMINUM FACP FIRE ALARM CONTROL PANEL INSUL INSULATION STIR STIRRUPS DRAWING BY: �C AMP AMPERE, AMPS DBL DOUBLE FCO FLOOR CLEANOUT ISA INTERNATIONAL SYMBOL OF STRUCT STRUCTURAL ARCH ARCHITECT, ARCHITECTURAL DC DIRECT CURRENT FD FIRE DAMPER, FLOOR DRAIN ACCESSIBILITY SUMP SUSPENDED W/ WITH SYMM SYMMETRICAL W ASHRAE AMERICAN SOCIETY OF HEATING, DEG DEGREES FIN FINISH (ED) N/A0 WITHOUT CHECKED BY: TL REFRIGERATION AND AIR FIXT FIXTURE / NOT APPLICABLE SiSJ SAW JOINT WCO WALL CLEANOUT DEFS DIRECT-APPLIED EXTERIOR FINISH NEC NATIONAL ELECTRICAL CODE QTY QUANTITY SOA SECURITY OBSERVATION AREA CONDITIONING ENGINEERS FDN FOUNDATION I WC WATER CLOSET ASTM AMERICAN SOCIETY OF TESTING SYSTEM V NEMA NATIONAL ELECTRICAL DGG DENS-GLASS GOLD FLG FLANGE MANUFACTURER'S ASSOCIATION WD WOOD AND MATERIALS DIA DIAMETER FTG FOOTING WL WIND LOAD AVG AVERAGE DIM DIMENSION FS FAR SIDE J-BOX JUNCTION BOX NF NEAR FACE T WP WEATHERPROOF DATE: 12-16-2022 DL DEAD LOAD FF FINISHED FLOOR JT JOINT NFPA NATIONAL FIRE PROTECTION I WO WALL OPENING B DN DOWN FLR FLOOR JST JOIST ASSOCIATION T&B TOP AND BOTTOM WWF WELDED WIRE FABRIC DS DOWNSPOUT FLUOR FLUORESCENT NIC NOT IN CONTRACT W WIDTH DTL DETAIL FR FIRE-RETARDENT-TREATED Il NL NIGHT LIGHT RA RETURN AIR T/FTG TOP OF FOOTING WF WIDE FLANGE (STRUCTURAL) JOB NUMBER: 022139 BC BUILDING CONTRACTOR DWGS DRAWINGS MATERIALS K NO NUMBER RAD RADIUS THICK THRESH THICKNESS OLD BLDG BUILDING FT FOOT, FEET NOM NOMINAL RCP REFLECTED CEILING PLAN BM BEAM FRP FIBERGLASS REINFORCED PANEL k KIPS (1000 LBS) NTS NOT TO SCALE RD ROOF DRAIN TOJ TOP OF JOISTTO TOP OF TITLE: BOTT BOTTOM kV KLOVOLT RE: REFERENCE, REFER BTU BRITISH THERMAL UNIT [ kVA KILOVOLT-AMPS REINF REINFORCING TOS TOP OF STEEL BOF BOTTOM OF FOOTING L kW KILOWATT O REQD REQUIRED THRU THROUGH BRIG BEARING G kWH KILOWATT-HOUR RHC RETAIL HEALTH CENTER T THERMOSTAT COVER SHEET BET BETWEEN EA EACH RM ROOM TYP TYPICAL XFMR TRANSFORMER OA OUTSIDE AIRON CENTER TS TEMPERATURE SENSOR EC ELECTRICAL CONTRACTOR GA GAUGE RD ROUGH OPENING EF EXHAUST FAN GALV GALVANIZED OCC OCCUPANTS RPM REVOLUTIONS PER MINUTE T&G TONGUE AN� TRC E ELEV ELEVATION OF OUTSIDE FACE RAL) EJ EXPANSION JOINT GC GENERAL CONTRACTOR RTU ROOFTOP UNIT TR WOOD PRESERVATIVE-TREATED SHEET NUMBER: GB GRADE BEAM MATERIALS EIFS EXTERIOR INSULATION AND GWB GYPSUM WALL BOARD LB POUNDS OD OUTSIDE DIAMETER CF CUBIC FEET FINISH SYSTEM GAB GRADED AGGREGATE BASE OH OPPOSITE HAND TS TUBULAR STEEL (STRUCTURAL) CERTS CERTIFICATES ELEC ELECTRICAL LF LINEAR FEET TRS TRUSS (STRUCTURAL) LL LIVE LOAD, LANDLORD OPNG OPENING CFM CUBIC FEET PER MINUTE EMBED EMBEDMENT LLH LONG LEG HORIZONTAL OSHA OCCUPATIONAL SAFETY AND S YD YARD CKT CIRCUIT EMP EMPLOYEE HEALTH ADMINISTRATION SC SITE CONTRACTOR EMS ENERGY MANAGEMENT SYSTEM LLV LONG LEG VERTICAL CENTERLINE SCHED SCHEDULED ENCL ENCLOSURE HGT HEIGHT LONG LONGITUDINAL LG CEILING LT LIGHT P SCHR SECONDARY CHILLED WATER CLR CLEAR OR CLEARANCE ENT ENTRY, ENTRANCE HORIZ HORIZONTAL RETURN UL UNDERWRITERS LABORATORIES, CMU CONCRETE MASONRY UNIT EQ EQUAL HP HORSEPOWER OR HIGH POINT LP LOW POINT SD SMOKE DAMPER, STORM DRAIN INC. CO CLEANOUT EQUIP EQUIPMENT HTR HEATER LTG LIGHTING PAR PARALLEL SECT SECTION LION UNLESS OTHERWISE NOTED COMMENTS: COL COLUMN EXGR EXTERIOR GRADE HVAC HEATING, VENTILATING AND AIR LWC LIGHT WEIGHT CONCRETE P/C PRECAST CONCRETE S SENSOR UPS UNINTERRUPTIBLE POWER CONC CONCRETE, CONCENTRIC EXH EXHAUST CONDITIONING L LENGTH PC PIECE SF SQUARE FEET SUPPLY SIGNAGE SHALL COMPLY WITH 2010 ADA CODE DATA (2020 BUILDING CODE OF NEW YORK STATE ) STANDARDS. SIGNS SHALL HAVE A NON-GLARE FINISH. CHARACTERS AND 1. USE AND OCCUPANCY CLASSIFICATION (302) SYMBOLS SHALL CONTRAST WITH THEIR MERCANTILE GROUP - M (309) BACKGROUND. STORAGE GROUP - S (311) TACTILE EXIT SIGN, INTEFNATIONAL SYMBOL Nonseparated Occupancies (508.3) AM MOUNTED ON FRAME 2 9 01 NOTES TACTILE EMERGENCY SLIDING DOOR OF SLIDING DOORS. TOP OF TEXT COLOR SHALL OF A CESSIBILITY WAR lY EXIT SIGN SYSTEM RE: 4/G4 SIGN CONTRAST WITH SIGN 1 -3 2. CONSTRUCTION TYPE: phouff GICIf RE: 4/G4 E EMERGENCY BACKGROUND. O 1 TYPE IIB CONSTRUCTION (SPRINKLERED) EXIT ' TACTILE CHARACTERS SHALL 0 �► WAITING - XBE SANS SERIF FONT (ALL zL _ z 3. BUILDING HEIGHT (TABLE 504.3): 1 STORY (NO CHANGE) 'Co UPPERCASE) WITH MINIMUM `° 4. BUILDING AREA (506.2): 14,249 SQ. FT. (NO CHANGE) RESET � nNL �`' HEIGHT OF 5/8 AND i \ o ooQ oo"�oo„.o a MAXIMUM HEIGHT OF 2';, N TOTAL FIRE AREA: 14,249 SQ. FT. (NO CHANGE) STORE NUMBER 03105 r WIDTH OF UPPERCASE 0 FINISH \ OF FONT SHALL BE MINIMUM o FLOOR TOTAL BUILDING FLOOR AREA: 14 249 SQ. FT. (NO CHANGE) GRADE 2 BRAILLE EITHER 60% AND MAXIMUM 110% ACCESSIBLE 9870 MAIN ROAD ._ CENTERED OR JUSTIFIED LEFT 3/8” MAXIMUM HEIGHT OF . MEN z WOMEN RESTROOM WAITING SIGN 5. DESIGN OCCUPANT LOAD (1004.1) MATTITUCK, NY 11952 MIN BELOW TACTILE CHARACTERS. UPPERCASE "I." STROKE : _= M 3::"= M 3 7117X" Retail/Sales (60 sf/occ.): 10,360 sf / 173 occ. PROJECT TYPE: (72) RESET o z SEE 2010 ADA STANDARDS FOR THICKNESS OF UPPERCASE "I" BRAILLE SPECIFICATIONS. SHALL BE 15% MAXIMUM OF z Pharmacy 100 sf occ. : 993 sf Y � ) / 83 occ. FINISHED THE HEIGHT OF THE FINISHED Receiving (300 sf/occ,): 2,296 sf / 8 occ. 00 AT RETAIL EGRESS DOOR AT SLIDING DOORS FLOOR CHARACTER. FLOOR ACCESSIBLE MgrOffices Off&e (100 sf/occ.):Misc (150 sf/occ.): 246 sf / 3 occ. CS PROJECT NUMBER: 165265 • CHARACTERS SHALL BE 1 EXIT SIGNAGE DETAILS 2 TACTILE EXIT SIGNAGE DETAILS RAISED 1/32" FROM SIGN 3 ACCESSIBLE RESTROOM SIGNAGE 4 WAITING SIGN TOTAL OCCUPANT LOAD 270 occ. G4 SCALE: 1/4" = 1'-0" G4 SCALE: 3" = 1'-0" SURFACE. G4 SCALE: 3" = 1"0" G4 SCALE: 1/2" = 1'-0" 6. EXITS ARCHITECT OF RECORD: A. Egress Width (1005.1): Required 270 x 0.15" = 40.5" Provided 54" NOTE: M B. Min. Door Width (1010.1.1): 32 Clear MERCHANDISE FIXTURES ARE SHOWN FOR REFERENCE ONLY. C. Number of Exits (TABLE 1006.3.2) From each Floor No. Required No. Provided SBLM Ground Floor 2 3 545 West 45th Street 4th Floor NOTE: New York, NY 10036 NO CHANGE IN USE, EGRESS OR OCCUPANCY WITH D. Travel Distance (TABLE 1017.2) T: 212.995.5600 F: 212.675.4228 THIS APPLICATION. Allowable 250'-0" L.F. www.sblm.com Provided 201'-2" L.F. NOTE: F. Min. Corridor Width (1020.2): 44" CONSULTANT ENGINEER: NO CHANGE TO PLUMBING FIXTURES COUNT WITH 7. FIRE PROTECTION SYSTEMS O THIS APPLICATION. A. Sprinkler System (903.2.7): Required YES Provided YES ......... ......... ...... ............. . ....... . ... .. POINT A .. ......... ....... . .... ... ........ ........j'.. IOW y B. Standpipe System (905): Required No Provided No ��` HE�DERSN r n N �, „ C. Fire & Smoke Detection (907): Required Yes Provided Yes ;. �J ENGINEERS EXIT ;� '° _ i i 180 D. Fire Alarm (907.2.7): Required No Provided Yes 8345 LENEXA DRIVE, SUITE 300 1 1 0 0 0 0 m I 4'_6" - //o I s E. Smoke Vents (910): Required No Provided No 320 '` I , KS 66214 1 ; ............. .I TEL 913.742.5000 FAX 913.742.5001 7'-10" I I � "�,, F. Portable Fire Extinguisher (906): Required Yes Provided Yes � � 'I WWW.HENDERSONENGINEERS.COM ri O 6 1 4'-6" <; // I a ♦ _ 8. MINIMUM NUMBER OF PLUMBING FACILITIES (Table 2902.1): POINT B 1 4'-s" 5'-6" Total Occupancy Load: 270 OCC. r 1 9" - '- • -6r -8 -0" 44'-8 • I --I Required: Provided:4- 4X1 46 O 1 s 9'-3" s I `� Water Closets (1 per 500): (NO CHANGE) CONSULTANT' 2011 Lavatories (1 per 750): (NO CHANGE) 1124 1*000 I 4 DDrinking Fountains (1 per 1,000). (NO CHANGE) O 1 13 19 �� b, N I Service Sink (1 required): (NO CHANGE) ,� a $moo 4'-6• V e 1 14 4'_6. 18 %s• 4 _711T=4 10" -�-- - ---- ---- - jar- ---- -jr- a , �'P �♦/ 4'10 a 4'-s• `� I� ■\ I 9. ACCESSIBILITY (TABLE 1109.11): 4'-9" 16 "' o I� �� i i " 4'-3• Required Number of Sales/Service Counters to be Accessible. oo eve ie 1 _ e I 1 01 I o . '-o• Total No. Min. No. No. 5110" ' , a io-foMN N fl�Iij Jt I Required11 uired Provided X 9(TV' ACustomer Service 5 1 5 ° `"o 5'-s" 4'-s~L -o" o -6" 1,_ 1 2B - Pharmacy - DroP- Off 2 7'-s" " 4'-4 6'-10• Pharmacy Consult 1 SEALW/TOP CAP FILLER BOX 0' �c y - 11 10 9 7 65 41 3 00 i2 2nj0 D - Pharmacy - Pick-Up 3 1 3 ��5 PS M�CHq <� 4 4uo 5'-6" 4-7 I � N sl I * cn ¢ 10, EMPLOYEE WORK AREAS (2010 ADA STANDARDS 203.9) * g f J I t 4'-s" : o:W I 4'_0" The following s are considered to be employee work areas 14'-16 4'-8• a 9 P aces 1 i _ i' and are only required to be accessible to the extent required by V-6• a� � I '° section 203.9 of the 2010 ADA Standards for Accessible Design: S � 5-4f kl 0r 0 1 4'_s• I CHECKOUT (Employee Side) 1I-5' a C� � 1 11 I 4'-s" 1 ; I PHOTOLAB (Employee Side) 0� PAIX'CSA 1C, 1 i 6-4„ , MANAGER OFFICE RECEIVING AREA PP� REVISIONS: PHARMACY (Employee Side) 1 � ,o' 3„ 5'—'" DATE: ISSUE/REVISION: ---------------------- i \� 9'_ o" _:.:----- ---- ---- ----- 1_ ,. ,_a,. r ---- - - - --- - -� I SET } \\\ I "„� ' » > ” 3'—,„ � I 12-16-2022 BID/PERMIT \� g " o d I t2„ PP PP _ FT 30s• 1.2 L+J ® SYMBOL LEGEND w , \\ . C X ,x, cax,a asxt�ao xx,a so 1 0 o I \\ G/ \� • 6 „ ZZ 10 Ln In a 00 oo �uaiins i � � � �r � � � �. � � I `O �, I •, • .r :� �,' sv" er" 4) ACCESSIBLE AREA OR EXIT sPOINT C 875=43P AREA ROOM OCCUPANCY LOAD O 20 S.F./OCCUPANT EXI EXIT CAPACITY O �2°s 43 ACTUAL TRAVEL DISTANCE 240 ALLOWABLE DRAWING BY: JC O START POINT END POINT DISTANCE MAXIMUM TRAVEL DISTANCE FROM FARTHEST POINT POINT A EXIT A 175-11" 2070" CHECKED BY: TL POINT A EXIT B " PROVIDE LISTED AND LABELED DRY-CHEMICAL UL-RATED FIRE POINT B EXIT A 17171''-11-11" O DATE: 12-16-2022 POINT B EXIT B 197'-3" EXTINGUISHER POINT C EXIT A 151'-8° EXITILLUMINATED EXIT SIGN ABOVE THE DOOR JOB NUMBER: 022139 POINT C EXIT B 78'-3" TITLE: #A CHECKOUT OR TRANSACTION COUNTER OF A CODE INFORMATION & 5 FIRST FLOOR PLAN UNIQUE DESIGN " .. ACCESSIBILITY COMPLIANCE I I TACTILE EXIT SIGNAGE WITH 18"X18" CLEAR SPACE CENTERED 10N G4 3/32" = 1'-0" TACTILE CHARACTERS, SEE DETAIL X/A-0.1 FOR MOUNTING SHEET NUMBER: LOCATIONS rE j TACTILE EMERGENCY EXIT SIGNAGE WITH 18"X18" CLEAR SPACE CENTERED ON TACTILE CHARACTERS, SEE DETAIL X/A-0.1 FOR; MOUNTING LOCATIONS G4 momlmimimlm X HR FIRE RATED WALL COMMENTS: *Sgaure Footages below,or their sum,may GENERAL NOTES REMINDERS: Store Area Calculations not match data noted elsewhere on this plan PROJECT: RESET by architect. Total Store Area: Total Retail w/ Pharmacy CHANGES HAVE BEEN MADE FROM THE EXISTING 1.) MAINTAIN 12" CLEAR MINIMUM PUSH Store Square GROUP FILE NOTES MERCHANDISE PLAN PROVIDED BY CVS TO THIS OUTLINE CLEARANCE AT HANDLE SIDE OF ALL 14,256 S.F. (1st Floor) 10,771 S.F. Area Footage ALL HALLS BOD TRK POSTAGE RX RETAIL WNW SALLY PSE LVL1 PSE RX STORES COUGH DROP $ AMPS ITEMS ELEVATED EC HANSEN HOT LVL 1 3X84 PLAN AS A RESULT OF OUR RECENT ON-SITE FIELD DOORS. Receiving Area: Service Area: Retail-Main Level 9788 TRK MINI WANG HOTSPOT SPOT LABELS (3) SURVEY. ANY/ALL CHANGES MADE TO THIS PLAN WERE 1,870 S.F. 1st Floor 714 S.F. MINIMAL IN NATURE (LESS THAN +/- 3"), WITH THE 2.) MAINTAIN 18" CLEAR MINIMUM PULL Retail-Secondary N/A PHOTO SEASONAL BABY PHOTO FSHNREAD JDA TEST HELIUM EINSPIRE YPTKITY RETAIL ITEMS TRACKING WIPES APEX WlFUJI GLASSES ITEM LABEL BALLOON SPINNER TST KIT TM W/DUPLEX TIER 1 RACK DUPLEX MENS EVENT RACK FOLLOWING EXCEPTIONS: CLEARANCE AT HANDLE SIDE OF ALL Unusable Retail Space 241 RACK DOORS. Retail-Total REGIONAL WATERREGIONALDBNx ICEDEPaM gARWARE wwmNCEIx.R: COOLER wnrER DAIRY DISPOSE 10029 V RE POLAND WATER DEP POL JUICE DEP POL FILTRATION SKUS This square footage is for cvs merchandise SPRING SPRING SPRINGFSM J-HOOKS ENERGY LABELEVENT LABELS RX LABEL Pharmacy 952 BAR RACK WH EVENT 1. N/A „ „ purposes only and is not to be used to GLAIREs CO By AYBELLIN ONSUMABLE IETNUTRITIONn HH ORAL SHAVING HAIRCARE 3.) MAINTAIN 30 X 48 CLEAR FLOOR Pharmacy Consult Room N/A ELEVATED COLGATE HCSKINNY MINIPOP 9�P�PN' CLEANERS HYGIENE NEEDS MINI MINI POP ' ' ' SKINNY TOWER SKINNY TOWER TOWER UP MINI POP UPMH POP UP POP UP SPACE AT ALL FLM s, E.C.0 s, B.P.M. s, calculate required egress or code requirement Pharmacy-Total 952 UP 1 'FORTO -5HOUR LACTAID LIQID IV MNYGRM PEST SKINNY REGIONAL GFT HERSHEY J-HOOKS RESET A.T.M. s, COPY MACHINES, LOTTERY Health Hub Clinic Room N/A BEV ENRGY SUPPLEMENT' BEV CLR CNTR TOWER(9) CROS-OMNY- SYRUP PHARMACY SYSTEM SUPPORT FIXTURE TRACKING NY(DC NJ) MACHINES, COIN STARS, CUSTOMER Health Hub ClinicRoom2 N/A BEVCLR RACK p. RX SYSTEM SUPPORT ITEMS EXISTING NEW SERVICE COUNTERS, FIRE EXTINGUISHERS, Health Hub Clinic Room 3 N/A I RTC WIRE ISINGLE RACK CNVIBLKUT GLASSES EPFORMAT O°HLABEL RKCHEC OUT ABOOKSC ENRXQ�X3a STORE NUM6ER' 03105 POD CORE 15 TISSUE HHC (66 PRINTER EVENT 11X60 3PANEL Health Hub Lab N/A - - 9870 MAIN ROAD COMPUTER TERMINALS 8 AND FIRE PULL STATIONS. AKE-AWA TOC F3 M&M FRONT OUEU C/O CNDY ACO (I.E. D0, DT, LU, QA, PROD) POS/REGISTERS 4 ) PHARMACY DISPLA MATTITUCK NY 11952 4. MAINTAIN 36 MINIMUM CLEAR PROGRAM TENSATOR UNI WALL NO Health Hub Waiting Area N/A MACS LT @ CHECKOUT & DT BETWEEN AISLES. 18FT8PANEL Health Hub Total N/A ' ( ) Wellness/Sales Room N/A CLUSTER DEFINITI❑N NOTES AREA DEMOGRAPHICS PROJECT TYPE: (72) RESET PRINTERS 5 5.) MAINTAIN MIN 18" X 18" CLEAR FLOOR Standalone Clinic Room N/A DRIVE RX REAR THH3.0 HISPANIC AFRICAN AMERICAN SCANNERS 4 SPACE AT ALL TACTILE EXIT SIGNAGE AND Standalone Clinic Room N/A AISLE OF STORE N/A N/A STANDARD (� PROJECT NUMBER 165265 (I.E. DO) TOILET ROOM SIGNAGE. . Standalone Clinic Room 3 N/A LP-WITH RISK INDEX � FLM MAP KEY Home Health Fitting Room N/A LPTIER2 CK-COKE PS-PEPSI Optical Exam Room 1 N/A Optical Exam Room 2 N/A OFF SHELF MAP KEY ARCHITECT OF RECORD' HALL Optical Retail Area N/A BEAUTY QUAD HEALTH QUAD 81090 EX. FIRE ALARM Optical-Total N/A LIP CARE P.W. ACE-ACE BRACES P.W. ANNUNCIATOR Vaccination Room 1 39 LB-UP BAR FLOORSTAND IT-IMMUNITY PREP TOWER KEYPAD GB-GLOSS BEAUTY DISPLAY CT-COVID TOWER O Vaccination Room 2 N/A ST-PRO SALON TRIAL SIZE F.S. II-CANE SPINNER Vaccination Rooms-Total 39 FP-FOOT PETALS F.S. OTC-STORE BRAND OTC F.S. Other 1 N!A MEN'S ....NXL.4 x13x7 ........I CW-CLAIRE'S HAIR ACC F.S. O-MEDICAL DEVICE TOILET COS 59W 44G SEG /ESSI Q TR#6505 Www Other 2 N/A BATTERY F.S. SBLM n n �Yo X ANK KITSCH P.W. r o cD ii I °ao LIGHTED SIGN CP-COPPER FIT POWER WING 107 I , ; m 4th Floor ... .... Street 1 ,, 36x 3x7 L48x13x78 ix�36,�13r'x ... ......... ....N L�4 13x78.... ......... ... "'. ^ / I $'-01 LAI HR ACS W AB FASHION 16X78 HAIR APPL S 59W 44G SEG W SSIE HQ STR#6505 N I �0 Ln a I Lo �a nr� 9x7 4X72 It - wNW �GPQ //,� , VESTIBULE H New York NY 100 �`� AS-ARCADIA BOOKS SPINNER ' G AR o 0 0 0 o I ELEVATED P ao5o Rll^I I ;.?� 100 LC-LIGHTERS/PLAYING CARD T: 212.995.5600 F: 212.675.4228 SCNDRY I I I I I LA GIRL EC WINS q'_6" "w O O 1 A 101 nn EhN n / ' 1 4, J LO GC EC Ln Ln ELF -1 - JOAH LEVATED MyM ' - HJT Y��- UR-SHOE/SEWING P.W. www.sblm.com ENDCAP ENDCAP LEVATED LO COSMETICS ENDCAP LooVMP F z RX (OPEN) (OPEN) EC (O FLOWER ENDCAP T wire3tie: 9X6tX6 t� XElX4 °} C/O CB 21 ° " ala. m Fs o •�, BACKSCRATCHER P.W. 11 " WOMEN'S W ° o } 'W os, "'''�?» CONSUMABLES TY-BEANIE BABY FLOORSTAND d U m 3A0 1D d °z X t� m W 7'—10" yF I EX. BETHPAGE ATM TOILET O U48' � w N O z Xp XX d v o x m Q P` ^ LIGHTED SIGN HF-HARIBO FLOORSTAND #-DIE CAST FLOORSTAND CONSULTANT ENGINEER X o o }a w C) " 0 a =a o � 4 -6 a Q 0 \� I 0 Q HE-HELIUM TANK 1 O8 N O u D ID U m o / // 5 Q X Y -' 0 z = rxi m !r ° rxi 0 w m (G C'P ! i i 5 `� I " O U d x x o O m U W X 0 x x W ' a°5° •J Z ;/ i 23-RAINLP GEAR IPOPAFLOORSTAND 8'-0" U O O w N X X (nJ O X X O N I� O O Z ° %j q2 U o LO o 0 o m m Z '-6" Z Q ID co co LO LD 5'-6' ,S, /, 1 Zv qQ r QL 9• I m } x x u) O N U g W to O T°n W ? x x S•; \ I W r D r Ir X co1 11 Q'Q' LL OJ J # iRf TA�13t£ 4-9 _ �4-6 = I= ,� r n� 2 W d 4'-6"r o N p a p G �•, ° 4-6 , °DF° o o M J J O S' 5'-D _61 = £ 4-6 M M X ti % ----- -- w NENDEREON o w 4X1 W W Z �� F \o' ; ;�_�_ �, F J COSMETIC CLASSIFICATIONS: COS MGR 3 oR AR o GNESG O x x I_ ° 1 + y+ _ Z ENGINEERS BREAKR00 N W W ^ EVNIX PLEY m 0. d a x J Cos EC o v a J d Y 9 -3" sOi; toroG 9/S u =Y NOTES X J (O 5 U = w " oo CO J J V LL w - (�1 I a m U SVO 105LU x to 8'-0 Ez U o Y o o RNR DARE o x x w _ _ '� ~ - Cosmetic Planograms , p x X = I T w ° `� N ^' Z _ %�' ! i r M 8345 LENEXA DRIVE SUITE 300 d "`EY 3 : z 4_6 ¢ Q i > x LENEXA KS 66214 ` (� T RAq( U Ll O ;S 4x13 c+l L,.1 w ENDC4P 1 X J r 1. I , -n -9" (EXIST) WATER HEATER m o O X (OPEN) x x f- txro £ �C' J "N W U J m m m ro O rn o m v v U U , ° N , D } I HECKOUT 'REVLON 156X78 SPL TST 12 v � w W 4-s" x 20 s>: 4-7 m TEL 913.742.5000 FAX 913.742.5001 ON SHELF ABOVE. n co CO o f J =$ D J ? m rn w J o I ; 0 °7 102 F I m ¢ w HTHY 'LORL 168X78 SPL TST x x J X n oo O : O C7 W m o o m> m o x Gn ' g CX 1 n U co J d w w°D Z v d x m m w = Z v SKN DSd ' DN a I- N ° x x W m N LABEL, '' I Z + N 10,-9" WWW.HENDERSONENGINEERS.COM (EXIST) m C) J J og 13 D v CL � M m 19 <° 11 a ° I o > O x o C. H m x x y w X 'MAYBELLINE 160X78 SPL MOP SINK. N N W F- 0 ' z z m _ 3 m . L) 4'-5 m wLL� RECEIVING X n0 m X w X 4'-6"m ; O U o ro w+ LL I AFFREEffT ¢ �NSKT B m �� z 'COVERGIRL 156X78 SPL TST a o J - Ir IY O a�� %' ' 00 AREA X J Q X 4'-s x ° Q o ----�-/ BUCHNA GL 12X78 I 0 m m a 14 3 = \—/7 •N mx row 18 - _ /°fit s'' /�� m 1 7'-::4' o v 6360 FILL 36X78 106 A ---m m--- -- -- o ° Y -- -- w V- = --- --- = - --------- - oo p P I j r 4- A o --_------- ----___ --_---_ -----_--- ' x 2 N CP 0---_ r.. S_----7 I ,� y I ---------- -------- x - ---- 10--- --------- ------ :" 1 / \ TIT, SAL HAN 108X60 W/HS CONSULTANT. R --- - --- -- - ---- < -- -- x - ---- N i OPEN) k+ I 16'-6 I EX. DOOR F J = j 5 J = 1 T HB O.: \ ; 4,10 $ I A J } Q CONAIR J /\ I J v c, 2 "� H m d cp GFT '� xetxse /" m L�____ SAL NAIL 72XBO ALARM KEYPAD J 4`-6 N Q `y X N ® _ INFLUENCE U' 5'-4" 1 m d ELEVATED RD i__-\! w U X x 0 I • ig 4r-311= I n O J 4X13X LL - ly X W z v ART NAIL 60X60 4'-9 = 16 0 +4 W a "? X °w PHOTO LAB EX. OVERRIDE NDCA i o _ FALSE LASH 60X60 BUTTON OPEN) I O O O ! H CARE 00 DO ava 1JD m x v 0- V M"\ . -" I 103 ACC IMP 72X60 I E I Oa' W L'•1 Jz I Z ° 11 y r 1 N 1 a u LASS Tlo of + w x In dx o �$p{ 10—9 "PHYS FORM 60X60 ' I 4X13X6 EHC^ O EC U W Z > Do I o 9 EX. SECURITY 5'-0" �. ; NDCA r,� I EX. COLUMN z z wo i I d o LL.U w , d, p \ ALMAY 48X60 " '� O ^ v1rA IN m cD , �, EX. CPC} t _ p MAN GERS NEUT 48X60 LIT ALARM KEYPAD CPC 4 13X i m aT I (TYP.) IL �'w LL BEV RAGES d (� z + GdOI .x,/o o �Yw WOR COUNTER Y t3- I GNC 101 Q1 NDCAP BFa w (e)l,o ' (e)II U o co i ` I 0 N -11" _ 4'-5,r 5'-6" wv oeB BNB o o 0 11 _ -0 4'-7 ° 51 11 6'-6 1'- K X SEEP MINI I6 32 32 TH ENDCAP LD � ccTD UTIOUE Z .: z �' " LLERG REMEDIES THH ° `, ° �� OMITTED DEPARTMENTS: tx Fa rx R UJ 7'-6 4'-4 O O o ¢ 6'-10" 3sx1ox512 w EX mx IRK xz m= °xo N FILLER BOX 1', %II )IGMEM0'- j� ��,REE HOTOSERVICES • #VITMN FOCAL SPL • AS SEEN TV s m w } rn= d m= Y a ' ; BxSareo(3 3PANEL • )KBEST SELLER EC • A X Z F F W/TOP CAP 1: I I I� ° BABY GIFTING '' "� �' W :�: I°O `, - in I W DME-MICHAEL G EC BEHIND C/❑ GRAPHICS X 11 10 9 0 8 a Q 7 a 6 5 Y x: 4 3 X • _ 0 3x60 Q ICK io SPL FACE FOCAL A FACE SPL BETTER TG EC I I 1 I PP CL m POV.ER (q x • EX. SECURITY ; i i i 11'-2" < J o Q Q Q axo > g :�: BATT EC� I o�PE"B DSD BI ES m ALARM KEYPAD I X z o 4'-7'' -7"cZ, :�: sxsa I SNACKS 3 o c3) 5'- x SPL FACE FOCAL B GREETING CARD SPL SEAL' I ¢ _ I NUTRN X 3x6 J a z J FACE MASKS 3X60 HEALTHY HYDR EC RED AR L _______ T-------- } _ _ :•: 0 iivs I! BARS cusr o N • SNAIL GONDOLA SPL • PEPSI BFY COOLER V /� v !n 11 0 C BEACON o ¢ H i FIXT EC `w w X 3 6U a m r S 'V l.� FINISHED 13'—11 `-- N )KPERS❑NAL CLEANSING MEN REUSABLE BAG G�5 P5 MII-NA < �T p -r.1► o d o a o W OI N x Qo W 0 0 0 0 ; Yia 1VN SNC6X60A ED \ , • • C.�z ° � x L° � 5'-8 PEM t „ " PREPAID PHONE WALL SPL STUDEX EC rT --', I ti ! LL ¢ in LL m Jo m -' EX. ACCESS • wSHAVE MALE SPL TOC LIP CARE SPL \ �f I- D- ENDCAP - � x jf j N ��ii 1� �I 9 �, m r J 2n J m YM W 05 D, D, co = ; 8x72 -- *TREND EC HHB '� a °PEN) o PANEL FOR N 4 -6" a xetxe — �'� In°m " F I 4'-0" FRITO AsI �___- -a VITAMIN PERM EC 14'-10 LL x 4-8" x ° o W z COOLER S S 3 I J o rN > H Y Q p J �O u)i W w i 8x 3x72 _ SH i` %i CC VITAMIN FOCAL SPL ii A O w a' N = (OD IOD J X CC G� ? O I O J z J W F- X X (OD O •pj F- l/..I O Q. O I \/ T'D r X o OO ¢ 03 -' al O x a so. 1 �� m X , — .` EX. ELEC. (; t----- LD x x IL Z 5 x x x J -�� cou) Lo PANEL D ..,» Fn —4" ' \ , F- X o� r� Q }O 0 o 0 ro m v ' 2 I , S ® U r `»i Fes- rNi x x D' 6-X x x O 4'-611 J J o z :m: m X OD OJ H d m J 'v' Z I W n1 (EXIST)1C-r FILL STATION w 0 c7 T 5 -T4 W O a v X M M 4'-6" O /D U J =- 1 Ir U I O e ----- OPEN 9B Be W PRINTER W 88 Be J J J w z x d !1._5 o I V U (aa (aa (Ex.) (EX) (EX)(ETC)(EX) (EX) ® NISHED ; `\ o ° ' `'d co X N = _ = I X ' -- EX. SECURITY lr� 409 ti� E ANEL i_ J J CLEAR 44 "- _ x �X � 00 -- GONDOLA FIXTURE VENDOR: COMP , m w D. 00 0 0 o ALARM KEYPAD 4 x¢ M 11 -5" N It W In a coo I LY x x SPACE PP r------- ; O O ... .. r co v S d d co co I U co LD ' , F ���p LRED ZONE�� ( 4'-6' -/ J X m m x x I [e m m V z <'T.1 COIAP PACK'G STA. T Cp1P .li1GWW£�•1 ... ' O x x ' -- LVlJGF\ �FOFI E ° ' _j �' SPECIAL MERCHANDISING NOTES: ® (DL) (DC) ' 1R1 `�> I I LEVATE IOD c� J J J i J J r l WASTE RET PRINTER 4 1 _l�f<wni_,I ENDCAP 00 N x `x W X m 6 -4 -- 10/24/2022 PRELIMINARY (,JLM) n_ (DL) (EX) (Ex) (EX.) (EX) (EX) 1 a m m L o 0 4'-i5" o REVISIONS: (DISI)10'-6'QA STATION '_ - `� o o X L) x �' 00 X 1 0 9 o • THIS STORE WILL NOT RECEIVE A CONSULTATION ROOM; 0_1a ,R,,,�6Tti R< 5 -2" 3 o J J o X - LL ° o oX -- RESTORED RX WORKBENCH TO CURRENT STANDARD DATE: ISSUE/REVISION: 3z " `i 10' 3" co d o } ; it v -- D • REMOVE 1 VAC POD ROOM AND RELOCATE 1 VAC POD ROOM AS \ . 6 >A xl =_ N o 0 4-9" 4'-5 m z Y 1 3 � ' x } d 5' 1 x LL o d rEPER PLAN 6€A� 8 1`; JFK ~°o LL o X _ ; o� __ z REMOVE ALL SPL FIXTURES 12-16-2022 BID/PERMIT SET I s s ug_ a W 3 °� M I Xw �> UPDATE EXISTING PHOTO LAB, ADD 3 WALL PHOTO STUDIO _9_'-1_0" - _ _____> _ _ ______ _ 1 -0" J �m __ I MERCHANDISERS --------- -- --- -- - --------- -- -- -----Y-- -- -- ------A,13X6 ---- ' 0 _r SLI �. w z' �, <�z o 5'_g"y 1 ADD RX TENSATOR FIXTURES TO PHARMACY AREA T� d U \',� I A Nlvs 3 -7W W z o 11) X171T- z -- I • UPDATE FIXTURE CONFIGURATION (EXIST) _a Fn W X �1-2rr \" EE STPNDIRGIEI�, ^ ^ LL R L X a W O V ENDCAP I -' 1 EXIS SPRINKLER 6 �, UPDATE FLOORING LINES W a m MANAGERS • _ /RISER � o O a m ¢ ¢ � �F 43X36 � _� 00 P RMA Y -- 1 U W am d a I; -- OFFICE • RELOCATE ALL THREE ECC F� (E ST)SPRINKLER n 7 O \ 1' DCA I I I • REMOVE 78" HIGH OPEN AIR COOLER (DSD GROCERY) AND 6011 \\ H. '?.'•i:i1'r':, v" J EZ2C 13X y f" 6x25.5x6 (OPEN) c , 110 F 4x13x <a m x13x60 4� 36x13 # ^ 0 0 1 11 L` \ 7'-7" •DR / \ - :CREADING VID1 $m 8 _ HIGH OPEN AIR COOLER PEPSI 9-0 ) t; Sr 5 X X I cLA ses ^ PET ANDLE OMO I I T / " (PEPSI) L�+ ° K O �\ CHOLES ,�i' �' NDCA TRACICINc REP EC i y O'_O 1 A FILLMASTERr,-r ^ i_____i °P�) TOYS EC 3X60 EC U Y "_(EAST) I O KIOSK CD I o 36X60 BULI`� I F OZ FD ICECRM RZ ` i J 10/31/2022 REVISED PRELIMINARY (JLM (EXIST) WATER METER 6CANNAS R r- I I I OVERFLOW/DRAIN B cauN ti - ; .y oD 10 #aLlns I ir3 I I I co --J REMOVE 2 PASS-THRU CHECKOUT REGISTER AND ADD 2 ACO "w (r ER _ I Oia)ailnsaNlOOv VAP HUM ch ART RFT I 'd 3DI j , REGISTERS FROM ANOTHER STORE 3-11 N 23 W w Y •fix CH REM 12X LIF 4X72 TI 4X72 78 STATNRY 24X76 cD M JUICE 72 a3Z Sad a3Z Sad f5 �® o�� M wTAINOPENAREA I V0tl IG os 18 "e ETDczwl I rr DI REMOVE PARTIAL CHECKOUT QUEUE FIXTURE AND INSTALL 4 I LasX 6X7s asX 6X78 plea svw idea svw 1,.IW I RA« IN TENSATOR SECTIONS PER PLAN • ADD 1 COKE AND 1 PEPSI FLM COOLERS EX. SET 12' FIXTURE AND CANDY PLANOGRAM ON 12' CHECKOUT EX. 3•cns ME WATER EXISTING - • RELOCATE FIXTURES€ D'BELLO BIN, FLOWER RACK, NEWS RACK NER DRAWING BY: JC O PIPE METER BPM WAITING EX. PHONE RELAY EX.COMPACTOR 111 cABINEr. UPDAAND TE WALKI RCADIA NO COOLEROK PERFMM COMMENTS CONTROLS CHECKED BY: TL 0 Iz S O Q � DATE: 12-16-2022 � Q H- n 0 W � LAYOUT DESIGNER JOB NUMBER: 022139 TITLE. JACK MELCHERT JACK.MELCHERT@CVSHEALTH.COM 401 770-4924 MERCHANDISE PLAN SHEET NUMBER: F= 1_ 1 OUTLINE FLOOR PLAN (1ST FLOOR) COMMENTS: F-1 SCALE: 1/8"=1'-0" r A H osL B C D E NOTES EX. FIRE ALARM 8' 0" ANNUNCIATOR 23 KEYPAD 1. COORDINATE ALL DEMOLITION WORK WITH 4. DEMOLISH ITEMS IN A WORKMAN-LIKE NEW WORK AND WITH FINAL MERCHANDISE MANNER FROM TOP TO BOTTOM OR AS PLAN. NEEDED TO PREVENT COLLAPSE. TAKE CARE TO PREVENT DAMAGE TO 1 2. THE GENERAL CONTRACTOR SHALL REVIEW SURROUNDING CONSTRUCTION. DO NOT MEN'S 28 I I I � THE ENT1R E DRAWING S o ET WITH THE TOILET I I EX. THANK YOU CVS DEMOLISH ANY ITEM THAT MAY BE 0 107 X32 • LIGHTED SIGN PROJECT MANAGER G ER AND VERIFY ALL STRUCTURAL IN NATURE, IF SUCH ITEMS narmacy - 3 I // I I PROPOSED WORK AND MEASUREMENTS IN ARE ENCOUNTERED CONTACT THE $' o� I , I // VESTIBULE THE FIELD PRIOR TO THE START OF ARCHITECT FOR DIRECTION 10o PRIOR TO CONS / TRUCTION. / DEMOLISHING THE I ITEM. 10.9 \� .\ :: :::::: ::::.::::::::::::::. ..:•: 23 3. NOTIFY THE ARCHITECT OF ANY WOMEN'S ( ii j / ° > ... DISCREPANCIES IN PLAN. RESET TOILET �i/ X/ ;;;, ; EX.BETHPAGE ATM STORE NUMBER 03105 /I LIGHTED SIGN 0 24 8 810 0. LEGEND (25 9870 MAIN ROAD fF1 _ �„ TABLE ' I `� MATTITUCK, NY 11952 �� ___�._ ...___` EXISTING PARTITION TO REMAIN �� KEY NOTE DESIGNATION f I — — PROJECT TYPE: (72) RESET BREAKR00 EXISTING TO BE REMOVED A (»a ��a.:::..::. :. :. . : 1 D5 // / 1 I , EX. WALL BOARD 81-0 \ :: :: :..... 1 COLUMN GRID `° S "Tp" %' ,' � i .i :::::::::::::::. 1 CHECKOUT CS PROJECT NUMBER: 165265 23 (EXIST) WATER HEATER i� �L ON SHELF ABOVE. iii /' 10 - 1 102 ® CARPET TO BE DEMOLISHED .: : : ::: ;:: i.:i:? 1 10's" RE/RELO: RELOCATE o (EXIST) 1 D/DEMO: DEMOLISH ARCHITECT OF RECORD �� ��.�..................... LL MOP SINK. �� / r I o:��:::::::: ::: :::::::: 1 F ¢ 1 LL VINYL TILE TO BE DEMOLISHED NOTE: ALL WALLS, DOORS, RECEIVING /� j i I r AND WINDOWS WITHOUT A ................ A I I I _-; - �/ r I ; 1 CUSHION BACK CARPET TILE SYMBOL DESIGNATION ARE Im 106A -�- -----------------_-_-__--_-_--_- _---------------__ r 1 EX. DOOR ------- ------- .:;:: ALARM KEYPAD F ' / 19 1� I i :! . `. r TO BE DEMOLISHED EXISTING TO REMAIN. t, Aft OI EX. OVERRIDE j j 11 I BUTTON /� r I I I i Q® . . PHOTO LAB 1 I I J p :;::` 103 NOTES BY SYMBOL • / rl SBLM j _��� o0 :; W :: 1 101.911O REMOVE EXISTING CART CORRAL. 1g RELOCATE EXISTING BLOOD PRESSURE E SECURITY _ _----------- ---------------------- ---- 0 545 West 45th Street 4th Floor A RM KEYPAD EX. CPC RETAIL / / r EX. CPC r MANAGERS MACHINE. / 1I wp„ . :::::: : :. O REMOVE EXISTING MILLWORK AND LOW New York NY 10036 I 101 / o. o WORK COUNTER , �/ I I / 1 ( �, . 1 WALL LAMINATE. 20 REMOVE EXISTING VACCINATION ROOM. 1111' r �� 1 0 :•'' ' 1 T: 212.995.5600 F: 212.675.4228 . 'MAU REMOVE EXISTING PASS-THRU CHECKOUT www.sblm.com - - I / - - - —�— — - ��� - „Y,` - O3 21 RELOCATE EXISTING VACCINATION ROOM. �n « P1 �� / ________ ______________________ - r o1k nu REGISTERS. __ --------- u EXISTING VCT TO BE REMOVED. � I --- _ EX. CPQ--' 1 n n i / ��� _ -— -_® -- `_---!J �4 EXISTING TURBO-AIR TO REMAIN. 22 . -- pp. I I O RELOCATE EXISTING PRINTER. 23 EXISTING CARPET AND BASE TO BE CONSULTANT ENGINEER: EX. SECURITY I i I REMOVED/ REPLACED. ALARM KEYPAD � � I b 1b / I O REMOVE (2) EXISTING 24" PHOTO CABINETS. EXISTING LVT AT BEAUTY TO REMAIN. FINISHED � j 11 O REMOVE PARTIAL CHECKOUT QUEUE E MERSO T,�g�Eyl I I I I I FIXTURE. 25 REMOVE MOVEABLE OBJECTS FROM S-2" 3'-7` 3'-2" 3'-9" ! I PEX. ACCESS ANEL FOR PLUMBING FIXTURE ADA CLEARANCE, ENGINEERS COOLER 8o MAINTAIN EXISTING OPTION C PHOTO 8345 LENEXA DRIVE SUITE 300 LAB. Y6 DEMOLISH EXISTING VCT AND WALL BASE ' g I I I I Ex. ELEC. LENEXA, KS 66214 LL 12 1 A PANEL D O EXISTING MILLWORK, SHELVES, GATFES TEL 913.742.5000 FAX 913.742.5001 I 9 EXISTING KODAK MACHINE TO REMAIN. 27 (Ewst)11 Fu sTAnon i F LL L- AND EQUIPMENT TO REMAIN, UNLESS WM.HENDERSONENGINEERS.COM ( (IX) (a) (E) ( )(EX)(EX) ) S ® _ FINISHED I I i-LL EX. SECURITY to EXISTING APEX PROCESSOR TO REMAIN. OTHERWISE NOTED. cwP T r� 4'-3"b� PANEL I I CLL ALARM KEYPAD EW PP DZONE ( ;8 ^ I ��L F 11 RELOCATE EXISTING ATM. 28 EXISTING FLOORING/BASE TO REMAIN. PACKG ST� T � L L a 3'-1" M] (a) I (a) � �x� I I 17 I 17 I I I ILL 12 RELOCATE EXISTING POSTER PRINTER. 29 REMOVE EXISTING PHOTOLAB CHAIRS. CONSULTANT' < 11R WAS Rff PPoNnR I li S3 s (IX) { ( ) (a) (IX.)(IX) I I CL o ( » a-! o.ASTA70 I � � I I LI- 0 13 RELOCATE EXISTING HELIUM TANK. 30 RELOCATE EXISTING PHOTOLAB TM S S32 I ��\\� j YL EQUIPMENT. a: \\ I I LL > 14 RELOCATE EXISTING MONEYGRAM. I --- r \�\\\ I ,� 31 REMOVE EXISTING SCANNER. I � s I I ��\\ I C Z 15 EXISTING COOLERS / FREEZERS TO 5'-9" o \�- ----J I REMAIN. 32 REMOVE EXISTING ACROVYN CORNER -- ---------------- -------- (EXIST)SPRINKLER ' \\ I t 7 L L RETAIL 21 20 MANAGER'S 16 EXISTING MILLWORK SPEC (COLOR) REMOVE AND REPLACE ALL GRAPHICS P 1 RMA Y MAIN/RISER �� � ; � � \\ 101 FLL � � � THROUGHOUT TO REMAIN 33 F� (EXIST) SPRINKLER 4JO ' �\\ I 17 I rLL �+� OFFICE AND ANCILLARY SIGNAGE. 110 I� -:g 18 \\� 101-9. I �-LL 104 17 RELOCATE EXISTING POWER POLES. 9,-0„ 4 S-5" o �\ --� ELZZL ZZ-774L r 8'-01/4" RE; ELECTRICAL 1 A \ LLLL LLLL LLL 116 23 -j O(EXIST)WATER METER �A ) — LLLL LLLL LL LL I o ACCSUITETE(RTC ACCIN SUITE (RTC AT FORMER RX WAITING AREA. O W OVERFLOW/DRAIN n�cau Q8 I �� LL 23 18 REMOVE FURNITURE SIGNAGE AND GRAPHICS 33 `�� 3'-11'x23 � �" ��' I ( SUITE#1 SUITE#2 � �� `I 1 LL (� ' a"n9 �����1 I — — — ♦ I ♦ I — 1 16 sew it a i� LL n�ac I S µ 4 VEAL' EX. 3" GAS EX.WATER EXISTING `���OIC gRCt,/,` o PIPE METER BPM WAITING EX. PHONE RELAY P`' CONTROLS COMPACTOR 111 J CABINET. ��0 O(P O orf (n )- H— 0— U .I . . . . . . . . . . . . . . . . . . . . . . . . — p —EX. WALL BOARD 0 7 3 �.�.� . . . . . I . . . . . . . . . . . . . . . Li Q .�.'.'. ��' 0409 wQ._. . . . . . . . . . . . . . . . . . . . . . J 1� . ... :....:::....:. . CHECKOUT =:= . . . . . . : : : : : 102 REVISIONS: : ::::::::::::: ::::::::: 1�(-9(I DATE: ISSUE/REVISION: w 232J7 12-16-2022 BID PERMIT SET 3 o cn. . . . . . . . . .'.'. . . . . . . . . . .' 4.I a.=.'.'.'. �o- Li 1 DEMOLITION FLOOR PLAN I J `� . �Dl1/8" = 1'—o" I 5. . ::. < �Z [0.� X32 0 . . . . . .. . . FEE] ' . . . . . . . . .... . . .'.'.'. �.N. . . ® ::::. ...: s PHOTO LAB DRAWING BY: JC "..� 103 CHECKED BY: TL �. . . . . . Ijv SIM — pa( . .'.'rno.0'.'. .'.'. .'.'.'.'. .'.0 I 11 go 10 -9 DATE: 12-16-2022 m Z(>u . . . . . . . " 23 4 j':':�` -: : JOB NUMBER: 022139 ' to : : :': :':': : :':':': N11003 a o00 EX. CPC 1 .:.:.:.:. . . MANAGERS TITLE: Nlv N3d0 NIv N3do WORK COUNTER 03)woti9 wol (e)woti9 w o :. alv-oeanl 2lIV oe 1 0 . .:. . . :. . . . . . . .: : . . �:3 ::: ::::::::: ::: : DEMOLITION FLOOR PLAN aannoT Mo aiv a3 no is ary 30 N SHEET NUMBER: v 31VO 1_119 g 2 �xAro,�R NOSY AD1 �l 29 31 H 2s 8 COMMENTS: 2 ENLARGED PHOTOLAB AND CHECKOUT DEMOLITION PLAN NOTES 1. INSTALL NEW/RELOCATE POWER POLES. REQUIRED TO FACILITATE CEILING GRID REFERENCE ELECTRICAL DWGS. MODIFICATIONS AND/OR RELOCATION OF 2. EXISTING PERIMETER SIGNAGE TO BE LIGHT FIXTURES. PROVIDE ADDITIONAL SHEET CONSISTENT WITH CURRENT CVS METAL, FLEX DUCT, HANGERS AND STANDARDS. GC AND CVS CPM TO ACCESSORIES AS REQUIRED TO RELOCATE 'Iy COORDINATE DEMO, RELOCATION, AND/OR AIR TERMINAL DEVICES. HVAC AIR TERMINAL RE-USE OF ALL EXISTING GRAPHICS. DEVICES TO BE MODIFIED SHALL CONFORM pharmacy 3. RELOCATION OF EXISTING SECURITY TO SMACNA STANDARDS. UPON PROJECT CAMERAS, MOTION DETECTORS, AND COMPLETION, AIR TERMINAL DEVICES AND SECURITY EQUIPMENT BY CVS VENDOR. GC MINIMUM 5' OF ASSOCIATED BRANCH SHALL COORDINATE INSTALLATION WITH DUCTWORK SHALL BE CLEANED FREE OF RESET VENDOR. DUST AND DEBRIS. MODIFICATION TO 4. REPLACE ANY STAINED OR DAMAGED EXISTING VENTILATION AIR FLOW SHALL NOT '' CEILING TILE THROUGHOUT ENTIRE STORE AS BE PERMITTED. STORE NUMBER: 03105 DETERMINED DURING PRE-BID 9. GC SHALL RELOCATE SPRINKLER HEADS AS WALKTHROUGH. REQUIRED TO FACILITATE CEILING GRID 9870 MAIN ROAD 5. REPAIR OR REPLACE ANY DAMAGED OR MODIFICATIONS AND/OR RELOCATION OF C INOPERABLE LIGHT FIXTURES AS REQUIRED. LIGHT FIXTURES. PROVIDE ADDITIONAL MATTITUCK, NY 11952 A B C D 6. RELO/INSTALL NEW AISLE MARKERS PER PIPING, HANGERS, AND ACCESSORIES AS PROJECT TYPE: 72 RESET CVS SET-UP MANAGER. REQUIRED TO FACILITATE SPRINKLER PIPING HALL E 7. CLEAN ALL EXISTING HVAC DIFFUSERS AND MODIFICATIONS. FIRE PROTECTION SPRINKLER 109 ENTIRE STORE. NFPA 13 LIGHT FIXTURE LENSES THROUGHOUT THE SYSTEM MODIFICATIONS SHALL CONFORM TO 81-0# RATION 8. GENERAL CONTRACTOR SHALL COORDINATE STANDARDS. FIRE ASUPPR STION DSIONESYSTEM CS PROJECT NUMBERS 165265 REVISED CEILING GRID AND LIGHTING DRAWINGS SHALL BE PREPARED BY A FIXTURE LOCATIONS WITH EXISTING CEILING LICENSED FIRE PROTECTION CONTRACTOR AS 1 DIFFUSERS AND REGISTERS. GC SHALL REQUIRED BY THE AUTHORITIES HAVING ARCHITECT OF RECORD' MEN'S I RELOCATE DIFFUSERS AND REGISTERS AS JURISDICTION. TOILET ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ;_-- _ _ Fl-0-7-1 --- --- -- --- -- --- --- — — --- --I I — — 81_0• 5 _ _T_ _ ___T f I I 2 1 I VESTIBULE LEGEND / M 11_ I I 1 __ I __ I �I _ 5 I __ I I 1 __ _� I __ I __ _ __ I 10 -9 EXISTING PARTITION TO REMAIN EXISTING ACOUSTICAL CEILING ' WOMEN'S r r 2 r r j j 2 r r j 4 TILE TO REMAIN I I I o I I 1 __ as _ TOILET ---T---T -- —T---T--- ---T---T— -- ---T— —T— --t— —+--- __ ___ ___ __ ___ ___ _ _ ___ ___ ___ ___ __ __ i I I I EXISTING ACOUSTICAL CEILING SBLM ® ___I � I I 1 I I I I I 1 I I I I I I I KEY NOTE DESIGNATION 8f_0# ® __ _ I I 1___ I ___ _�1 4 1 __ 1 __� L I____I I TILE TO BE REMOVED 545 West 45th Street 4th Floor — LI_-_-IJ FIXTURE DESIGNATIONS New York, NY 10036 ___ ___ _ _ _ —� E EXISTING TO REMAIN T: 212.995.5600 F: 212.675.4228 -r -- ---r---r--- r---r--- ---�--- r- 3REAKROOM ___ oj..__ I __ ___ I 1 --- 1 -- I ___ I 1 _ I 1 COLUMN GRID www.sblm.com I I I 1 1 I I T 7 1 I D DEMOLISH 105 ��� `-- I `-- -�'- RE RELOCATE 8'-0 —=-� oj--- -- I — — 1 --- 1 I ---t--- I— --- --- ® I I 7 CEILING FIXTURE SCHEDULE CONSULTANT ENGINEER: 4 `T " T---T`-` ```T`7 T--Ir `T "` -` ® I I CHECKOUT 102 EXISTING/DEMO/NEW SYMBOL DESCRIPTION I I 1 I I 2 I 10 _9• --- ----T---- T----�---- T---1---- -t--- ��R� -_- 2x4 LIGHTS RECEIVING --- --- --- -- I I I I I I I I I 1 r�'I`- ENGINEERS AREA --- ----1- -- -- ----T--- ---T--- --- �_�_� ® 1x4 LIGHTS ' 16'66' ® I j LENEXA, KS 66214 8345 LENEXA DRIVE, SUITE 300 6 0 o; Q 1x2 LIGHTS TEL 913.742.5000 FAX 913.742.5001 PHOTO LAB WWW.HENDERSONENGINEERS.COM 103 • • MONOPOINT LIGHTS 10'-9' RETAIL - :—:—: a—r—: TRACK LIGHTS CONSULTANT Bit I 3 8 1 12 0 l E EXIT SIGNS oi- °' ® ® D EMERGENCY LIGHTS 11 21 ® 1 1 I ®PP rfP mrP POWER POLE I ® ® II ® IMMIE==3 ® LINEAR LIGHT 1 ® o I I I xy ® HVAC SUPPLY 1 7 5 ' ° HVAC RETURN SEAL: MIRROR CEILING TILES ,��FtED ARC 1 50 ® �5 MICHA y�T � � kid 5 F< ® ® RECESSED LIGHT FIXTURE <p�Sp �N J O07 !_ J� 5 z NOTES BY SYMBOL * f II I �J Q 9 6 2 I O REMOVE EXISTING CHECKOUT HALO. �j REMOVE ALL EXISTING TRACK LIGHTING. J6LmitwKIX oRE: ELECTRICAL. ST 409 I I O REMOVE EXISTING WALL WASHERS. _ II RE: ELECTRICAL. O8 REMOVE BEAUTY WALL DECALS THROUGHOUT. RETAIL I I O3 REMOVE ALL EXISTING HANGING REVISIONS: 101 GRAPHICS AND AISLE MARKERS Og PREP VALANCE TO LEVEL 5 FINISH AND! PHARMACY 91 MANAGER'S THROUGHOUT, INCLUDING ASSOCIATED PAINT RED. DATE; ISSUE REVISION: 110 2 2 2 5 OFFICE HARDWARE. 9/-0# O 104 O 10 EXISTING RECESSED CAN LIGHTS TO 12-16-2022 BID/PERMIT SET O ___ _ _ _ 8'-0 1/4' 4 REMOVE EXISTING BROWN CEILING TILES REMAIN. 0 O 0 0 - - --- --- 5 --- - --- °- -° REMOVE EXISTING PIN LETTERS 11 EXISTING TRACK LIGHTING TO REMAIN. �1 THROUGHOUT. `t REMOVE ALL EXISTING CEILING TILE LEAK O 12 EXISTING HEADER TO REMAIN. DIVERTERS. RX WAITING 111 DRAWING BY: JC CHECKED BY: TL DATE: 12-16-2022 JOB NUMBER: 022139 TITLE: DEMOLITION REFLECTED CEILING PLAN SHEET NUMBER: 1 OVERALL DEMOLITION CEILING PLAN AD 2 SCALE: 1/8" = 1'-0" AD2 COMMENTS: HALL YUA 109 8'-0" � � D EX. FIRE ALARM NOTES ANNUNCIATOR 1. VERIFY ALL WORK AND MEASUREMENTS CONTRACTOR RESPONSIBLE FOR MOVING 41 26 KEYPAD IN FIELD BETWEEN CVS PROJECT ALL GONDOLAS LEVELING AND C) 37 MANAGER AND GENERAL CONTRACTOR STRAIGHTENING. PRIOR TO ANY WORK BEING DONE. THE STORE PERSONNEL OR STORE SET-UP PERSONNEL WILL MOVE ALL THE MENS I I I WWW MERCHANDISE IN HE STORE R TOILET JR, 2 CLEAN ALL FINISHED SURFACES (GLASS, T S 0 E P IOR TO o I I oV)o EX. THANK YOU THE REMODEL INCLUDING FRONT �— r I I ¢0 4 LIGHTED SIGN FRAMING, LAMINATE, CARPET, ETC.) AT 10� MI -11CIAR; 25 PROJECT COMPLETION THROUGHOUT CHECK-OUT AND PHARMACY. phQrmacymVESTIBULE ENTIRE STORE. 6. ALL EXISTING PHARMACY REGISTERS ARE � I // I 100, IBM TOUCHSCREEN. GC SHALL BE 40 42 45 51 \ --II AA11 TJ 4 10'- ' 3. ALL WORK IN CHECK OUT AREA SHALL RESPONSIBLE FOR SECURING A Ol �2 41 BE COMPLETED OVERNIGHT AND SHALL ALL T I o BE FULLY OPERATIONAL IF REQUIRED BY EXISTING EQUIPMENT TO REMAIN. RESET WOMEN'S r -_II rri�as -I _rt_ � // / I s LIGHTED SIGN COORDINATE NEW EQUIPMENT WITH CPM. -J u --I---� 25 // EX. BETHPAGE ATM CVS BY NEXT DAY STORE OPENING. STORE NUMBER: 03105 108 C) r � / I 4. THE PHARMACY SHALL REMAIN SECURE 7. ARCHITECT TO DO DUE DILIGENCE ON 8'-0" -� I--' , II I I I // I AT ALL TIMES. ALL EXISTING SPACES FOR I 3 ANNUNCIATORS AND PROBE LOCATIONS. 9870 MAIN ROAD 32 33 3440 == r/ 12 FF T 1 1 r�r 5. RELOCATED GONDOLAS (ONLY IF GC TO VERIFY LOCATIONS WITH FIRE MATTITUCK, NY 11952 42 45 51 I ) I CONTRACTOR HAS GONDOLA TRAINING). MARSHAL OR REVIEWER. PROJECT TYPE: (72) RESET BREAKROONC) 105 Lf 18 1 e'-0 LOOMOOAT RACK 1 I 1 I ! —— 1 LEGEND (DB (EXIST) WATER HEATER \ _= I �� ; i i 13 5 CHECKOUT CS PROJECT NUMBER 165265 ON SHELF ABOVE. I I //%��� 1 I o 15 0 I I I Z 1 101-91 EXISTING PARTITION TO REMAIN A �) (EXIST) 1 1 MqTa vTT „ B z 5 17 2 6 ARCHITECT OF RECORD: MOP SINK. I I �� 1 FINISH DESIGNATION 1 COLUMN GRID RECEIVING -- 11 o .• D 1 O7 41 # RE: SHEET AXX AREA � -- Ao ; �— I \ / z I 16'6" i EX. DOOR --_F ---, �\ / 1 j 8 �^ 1 //\\ AA 1 2 NOTE: ALL WALLS, DOORS, -•--� KEY NOTE DESIGNATION ALARM KEYPAD I �- I 50 24 /x\ 1 1 �[-- 1 Al AND WINDOWS WITHOUT A i I 1 I �_ 1 I ! w 14 g 1 SYMBOL DESIGNATION ARE EX. OVERRIDE I I 49 1 I i �`10 EXISTING TO REMAIN. I BUTTON I I I 1 1 i PHOTO LAB � 1 1 103 14 �° �� SBLM E SECURITY 9\X/ 1 I / 1\ 0 1 2 101911 41 I A RM KEYPAD EX. CPC 24 NOTES BY SYMBOL 545 West 45th Street 4th Floor IL EX. CPC --y ANA s New York, NY 10036 _ 101 ""�:I w� WORK COUNTER O CLEAN ALL GLASS 25 NEW/RELOCATED POWER POLE. 1 I 11'-11" I `"�'-- ` - 14 o i T: 212.995.5600 F: 212.675,4228 1 -� 0 2 PATCH, REPAIR AND REPAINT WALLS AS 26 CLEAN EXISTING FRP AND PATCH/PAINT www.sblm.com ,R N N 1� I o* ��� 2 O REQUIRED. WALLS ABOVE. RE;A7 EX. 1 1 BUMPERS 3) 4-0„ NEW MCCUE CART 27 INSTALL NEW TACTILE EXIT SIGN AT --- --- EGRESS DOOR; RE: 1 & 2/G4 CON EX. SECURITYSULTANT ENGINEER: F--i- ---� PP 47 52 16 I I I i 1 �p I 4 INSTALL NEW ACROVYN CORNER 28 INSTALL NEW RX DIGITAL SCREEN ALARM KEYPAD I 1 -_- 29 46 GUARDS.Fgli RE: 1&2/A7 — -- r I --� 30 I O5 INSTALL (2) NEW SCO. H� ® SCS _ FINISHED I � 29 NEW FREESTANDING MILLWORK RX WAITING S �x I X o EX, ACCESS O '� r.�91 I _W X � AREA, PER PLAN. J `s �a,l _�D I / 6 MILLWORK TOP AND EXISTINGMAINTAIN ALL S DES WITH EXIST ENGINEERS � I � COOLER SPEC; 30 INSTALL ACCESSIBLE WAITING SIGN. g SPEC; REUSE EXISTING SHELVING AND RE: 7/A5 8345 LENEXA DRIVE, SUITE 300 31 EX. ELEC. EQUIPMENT. / LENEXA, KS 66214 _ TEL 913.742.5000 FAX 913.742.5001 1 I r-- � PANEL D 31 RELOCATED BLOOD PRESSURE MACHINE. (��n,a��s<A,�R m I� / I I I I _ 7 MAINTAIN EXISTING MILLWORK END � ara ee OR PPoRTQt w BB BB 1 f X I I EX. SECURITY O PANEL, ADJACENT VESTIBULE, 32 CLEAN AND SANITIZE ALL SURFACES TO YVWWHENDER$ONENGINEERS.COM (EX) (E) (0c) ( ) (�)(cx)(a)(OLI I$ � FINISHED I / \: �( PANEL I I IICLEAR ALARM KEYPAD (INCLUDING GLASS INSERT & LICENSE REMAIN, INCLUDING DOORS, PLUMBING PP '> a T T (� I I I — IISPFCE BOARD) WITH EXISTING SPEC (COLOR). Zrn(E r I - FIXTURES, ACCESSORIES, ETC. Z m T rACK'G STA. T cam \'�aa-1 I I I 33 FRP TO REMAIN CLEAN AND REPLACE o ® cox.) I cam) g x I 11 I I I I 8 MAINTAIN EXISTING GATE WITH EXISTING SPEC, PER PLAN, was,E Rff RRMiFR "s` Liss`vz�l I 35 � � BROKEN / MISSING TRIM PIECES. CONSULTANT' CL (a) (FX) ( ) (a) CIX) CIX) I C3 L———-'1 of (oasq o'-e•O.A.STATO ` 3'-3"1I TRS 3z R(�`\\ 43 I Q NEW PHOTO CABINET. 34 PATCH AND REPAINT EXISTING FRP WITH -,z I D Lo PRO-WALL;RE: A5 „9 30"08"1 \\ w 1 1 I ^ g i CLEAR I �\\\ I I Z 10 RELOCATED PRINTER. � SPACE 35 CLEAN EXISTING WOOD DOOR; REPAINT DOOR VISION LITE AND FRAME. ] 11 INSTALL TENSATOR BARRIERS PER PLAN. ---------------------- IJv I _ \ \� -- - --- — ---------_----------------------------_--------------_-J I i _ RE: 1/F1-P 36 EXISTING FRP AND DRINKING FOUNTAIN TO __ BE DEEP CLEANED. ---------------------- ��\\''FESTaRD3r x� 24 RETAIL (EXIST)SPRINKLER G— y g I 44 25 P RMA Y --Mj/RISER d I - 101 I I r '� MANAGER'S 0 F CE 12 NEW COKE FLM 37 PATCH AND REPAINT WALLS ABOVE FRP. v (E)ySl) SPRINKLER 110 __ 7 �\\x I \X/; 101-9” 25 L+J 104 13 NEW PEPSI FLM ASTE38 RELOCATED VACCINATION ROOM. 4 n 91-01, _ ) \ \�, 25 ' I T 8'-0 1/4" 41 39 INSTALL NEW HORIZONTAL GRAB BAR (EXIST)WATER METERcd (SCANNAS Qt 28 -, _,—, 14 INSTALL NEW MERCHANDISE SHELVING W ( o/TcouNe I 1 I %8)3-ns13w00v UNDER CHECKOUT AS PER PLAN. BEHIND EXISTING TOILET; RE: 17/A6 OVERFLOW/DRAIN 38 r I I I Jj J/ O O / 3-11 x 23' a1 X.90 I 27 a3Z 3a� a3Z 383 1 " f~ I g I ad I l m vl I R& 15 INSTALL NEW CANDY PLANOGRAM AS SEAL; �� g I I I ♦ I - - r_ _ I I flea svw lvea svw iusw " 4 OPER PLAN. 40 VERIFY ALL EXISTING FIXTURES ARE MOUNTED AS PER 17/A6. NON COMPLIANT ,��RED A/�c EX. 3" GAS EX.WATER EXISTING FIXTURES TO BE RELOCATED. \5 MICHA WAITING 16 UPDATE ALL MILLWORK AND LOW WALL F<� O PIPE METER BPM i EX. PHONE RELAY LAMINATE TO OPTION C SPECS. EX. COMPACTOR 111 I ��— Tl F CABINET. 41 INSTALL NEW CARPET AND WALL BASE. ���� 0��� CONTROLS o RE: A4/A5 N 8._1111 ) x 12 17 RELOCATED POSTER PRINTER. Q 41 _ `r) I 42 18 INSTALL NEW CERAMIC TILE AND BASE = o a 0 18 RELOCATED HELIUM TANK. } u ( f -mu 13 I AS SHOWN/ SCHEDULED. o7 = (n — -� t9 INSTALL PHOTOLAB HANGING SIGN. RE; 5/A5 43 INSTALL NEW LVT AS SHOWN/ w e I Z D 5 S 04 .�- i CHECKOUT SCHEDULED. RE:A4/A5 T 09 AD N EXISTING GRILLES AND TOP OF 20 44 INSTALL NEW P.O.S. RISERS; MILLWORK 'f0 �- 11 m O 102 COOLERS. MATCH EXISTING. C7 ( 11 21 RECONFIGURE / SLIDE ALL GONDOLAS, 45 RELOCATE DOOR CLOSER ON THE PULL REVISIONS: n - Z 10 '9 PER PLAN, INCLUDING ROTATED SIDE. D 0 1 2 O6 HEALTH RUNS. DATE: ISSUE/REVISION: 138" cn _< 46 RELOCATED ATM. FREE STAN INGTENS17 7 41 22 MAINTAIN BEAUTY HEADERS. 12-16-2022 BID/PERMIT SET 47 RELOCATED MONEYGRAM. 54.25 In r 23 INSTALL/MODIFY GONDOLA END 48 INSTALL NEW PIN LETTERS; RE:A5 d 15 PANELS AND CORNER BOXES, AS °` 0 5 I .D REQUIRED. 49 REPAINT METAL DOOR AND FRAME PT20• OVERALL FLOOR PLAN I I� �i z o RE:A7 M Z <Z -1 - 24+ INSTALL NEW WECC (WELCOME Al 1/8" = 19-0" I n o N M m m CENTER), PER PLAN. O 50 NEW DRIVE AISLE PER PLAN RE: A4 M QCD o / \ 8 — — 51 INSTALL NEW COAT HOOKS;RE: 17/A6 VIE 9 52 INSTALL NEW SCANNER cn eN Z 14411 PHOTO LAB ,D DRAWING BY: JC 11 103 X ° ri DOA ° 101.911 CHECKED BY: TL 14 J O0 W mz� _ XO2 19 41 DATE: 12-16-2022 m\ _ EX. CPC 5 — — MANAGERS a3,o0' a 003 El JOB NUMBER: 022139 811 N310 I NIV N3dO WORK COUNTER tit9 ° TITLE: (e)wa9 (e)woIN NIV-oeo aIV oe 1 47 14 "�o,MOT'dd , aro Nd° FLOOR PLAN av310 31vs SHEET NUMBER: NOS`1 o MON RAM M„L� A 1 II 52 16 COMMENTS: 2 ENLARGED PHOTOLAB AND CHECKOUT PLAN AD1 ile = 1'—Ow NOTES 1. INSTALL NEW/RELOCATE LED POWER POLES. DIFFUSERS AND REGISTERS AS REQUIRED TO REFERENCE ELECTRICAL DWGS. FACILITATE CEILING GRID MODIFICATIONS 2. EXISTING PERIMETER SIGNAGE TO BE AND/OR RELOCATION OF LIGHT FIXTURES. CONSISTENT WITH CURRENT CVS STANDARDS. PROVIDE ADDITIONAL SHEET METAL, FLEX GC AND CVS CPM TO COORDINATE DEMO, DUCT, HANGERS AND ACCESSORIES AS RELOCATION, AND/OR RE-USE OF ALL REQUIRED TO RELOCATE AIR TERMINAL EXISTING GRAPHICS. DEVICES. HVAC AIR TERMINAL DEVICES TO pflak macyu 3. RELOCATION OF EXISTING SECURITY BE MODIFIED SHALL CONFORM TO SMACNA CAMERAS, MOTION DETECTORS, AND STANDARDS. UPON PROJECT COMPLETION, SECURITY EQUIPMENT BY CVS VENDOR. GC AIR TERMINAL DEVICES AND MINIMUM 5' OF SHALL COORDINATE INSTALLATION WITH ASSOCIATED BRANCH DUCTWORK SHALL BE RESET VENDOR. CLEANED FREE OF DUST AND DEBRIS. 4. REPLACE ANY STAINED OR DAMAGED CEILING MODIFICATION TO EXISTING VENTILATION AIR TILE THROUGHOUT ENTIRE STORE AS FLOW SHALL NOT BE PERMITTED. STORE NUMBER: 03105 A B C D E DETERMINED DURING PRE-BID 9. GC SHALL RELOCATE SPRINKLER HEADS AS WALKTHROUGH. INCLUDE UP TO (4) CASES REQUIRED TO FACILITATE CEILING GRID 9870 MAIN ROAD OF CEILING TILE FOR REPLACEMENT. MODIFICATIONS AND/OR RELOCATION OF HALL 5. REPAIR OR REPLACE ANY DAMAGED OR LIGHT FIXTURES. PROVIDE ADDITIONAL PIPING, MATTITUCK, NY 11952 109 INOPERABLE LIGHT FIXTURES AS REQUIRED. HANGERS, AND ACCESSORIES AS REQUIRED 81-0# 6. RELOCATION/INSTALL NEW AISLE MARKERS TO FACILITATE SPRINKLER PIPING PROJECT TYPE: (72) RESET 11 PER CVS SET-UP MANAGER. MODIFICATIONS. FIRE PROTECTION SPRINKLER 7. CLEAN ALL EXISTING HVAC DIFFUSERS AND SYSTEM MODIFICATIONS SHALL CONFORM TO _ _ _ _ ENGHT TIXTURE RE STORE. LENSES THROUGHOUT THEINSTALLATION IRESPRES S IONOPERATION NTRESTORE. STAND RDS SYSTEM CS PROJECT NUMBER 165265 MEN'S ® 3 8. GENERAL CONTRACTOR SHALL COORDINATE DRAWINGS SHALL BE PREPARED BY A TOILET REVISED CEILING GRID AND LIGHTING FIXTURE LICENSED FIRE PROTECTION CONTRACTOR AS ❑ .:•: .:• :•: . LOCATIONS WITH EXISTING CEILING DIFFUSERS REQUIRED BY THE AUTHORITIES HAVING 107 A C • .... ......... ......... .................... ..... . ......... ......... .................... ......... .. .... .......... 8'-0' VESTIBULE AND REGISTERS. GC SHALL RELOCATE JURISDICTION, R HITECT OF RECORD• 10. UPDATE KEY NOTES ASR REQUIRED. ......:..........:..:.:...:.:.:... .:.....:.:.:...:. ...;. :.:.,............ ...;... EQ O11 0 ® 100 I .................... ......... .......... ........ f ..•. ... .................... .:........ ....j.... ... :...... 10 -9 WOMEN'S 3 12 4 7 1 2 3 .; o... �� LEGEND .. ... ........ .......... ......... . e TOILET .. ... :......... los ...... ......... . ......... .......... ......... ................... 8 0 EXISTING PARTITION TO REMAIN ...... ..... ....... ............... ........ ..... .............. ......... ....I.... ......... ..... ........ NEW GYPSUM WALLBOARD CEILING 11 ......... .......... .. ...... ......... .... .... ......... ........ ......... ....... .......... ......... ......... .......... ... .... .......... ........ .... .......... SBLM O .. r----�--� ...... .. ......... ........ NEW PARTITION ......... . ......... ......... .......... ......... .... ......... .......... ......... .. . ......... .................... . ......... 545 West 45th Street 4th Floor .......... .. ... .. .. ... ......... ......... ......... ... .................... ... ......... .... .... .......... .... .... FILING TILE BREAKROOM NEW ACOUSTICA LC New York N KEY NO Y 10036 105 ......... ......... ......... ..... ......... .......... ......... ......... .......... ......... # TE DESIGNATION AND CEILING GRID 4 7 :•: ® T: 212.995.5600 F: 212.675.4228 so A ........ ........ . EXISTING ACOUSTICAL CEILING TILE www.sblm.com TO REMAIN 7 CHECKOUT 1 COLUMN GRID 102 o ......... ......... ......... . 10'-9' CONSULTANT ENGINEER: . ENGINE DESIGNATIONS ......... . E EXISTING TO REMAIN RECEIVING 4 N NEW ......... .......... ......... AREA1. ::::::::: RE RELOCATE lr Oo .......... .......... .. HENDERSON 16'-6' ENGINEERS B.O.T.= 14'-2° ID s CEILING FIXTURE SCHEDULE 8345 LENEXA DRIVE, SUITE 300 o I o I PHOTO LAB EXISTING/DEMO/NEW SYMBOL DESCRIPTION LENEXA, KS 66214 103 TEL 913.742.5000 FAX 913.742.5001 :PPrP]7: tot 10'-9' E= a 2x4 LIGHTS WWW.HENDERSONENGINEERS.COM RETAIL 10 LIGHTS 1 6 9 13 o Q 1x2 LIGHTS CONSULTANT' LU Ell • MONOPOINT LIGHTS ® 3 ® TRACK LIGHTS [I] ELI ELI TZ10 ® 0 3R£ )B( EXIT SIGNS 0 09 � D EMERGENCY LIGHT ®PP �P �'P POWER POLE 13 -�—�- ���==� ® LINEAR LIGHT SEAL' 3 I I I I x�1 HVAC SUPPLY ����5 MED Cy/T J� ® it b ® P' < F �� �� oA m? FN j HVAC RETURN 444- cn 5 4 �9 S O ® MIRROR CEILING TILES < ., M — — — — 3 ® � ® RECESSED LIGHT FlXTURE �'T 0409 �'E' RETAIL PHARMACY 3 44* l01 4 MANAGER'S 9110 3 0 OFFICE NOTES BY SYMBOL11*4 - REVISIONS: O 104 O o 0 0 0 12 4 1.. 3 8'-0 1/4' O REPLACE MISSING, DIRTY OR DAMAGED ACT. O PAINT EXISTING CEILING GRID PT20; DATE: ISSUE/REVISION: 4 ::::::::::::: :: 4 :.:, :.:.:.:.:.:.:.:.:.: 4 :.: :.:.:.:.:,:.:.:.:. 4 RE:A5 ......... ......... O REPLACE MISSING EGGCRATE TILE. OPAINT EXISTING HEADER PT20; RE:A5 12-16-2022 BID PERMIT SET O RELOCATED POWER POLE; RE: ELEC. g�REPLACE DEAD LIGHT BULBS THROUGHOUT. RX WAITING 43 INSTALL NEW WHITE 2x4 CEILING TILES. 111 MODIFY EXISTING GRID, SO NOT TO 10 INSTALL NEW MONOPOINT LIGHT 8'-11' RESULT IN CEILING TILE INFILLS - FULL FIXTURES AS SHOWN;COORDINATE WITH TILES ONLY; RE: A5 PHARMACY PIN LETTER LOCATION IN FIELD, RE: ELECTRICAL. OPREP EXISTING PHARMACY VALANCE TO RECEIVE LEVEL 5 FINISH; REPAINT. 11 PATCH AND REPAINT EXISTING CEILING. O CLEAN ALL DIFFUSERS, MIRRORS AND 12 NEW 2X4 LIGHT FIXTURE. EGGCRATE TILES. 13 INSTALL AISLE MARKERS. DRAWING BY: JC CHECKED BY: TL DATE: 12-16-2022 JOB NUMBER: 022139 TI TLE: REFLECTED CEILING PLAN SHEET NUMBER: A2 1 REFLECTED CEILING PLAN A2 COMMENTS: 1/8" = V-0" NOTES 1. VERIFY ALL WORK AND MEASUREMENTS 2. COORDINATE LOCATION OF FLOOR FINISH IN FIELD BETWEEN CVS PROJECT TRANSITIONS WITH MERCHANDISE PLAN. MANAGER AND GENERAL CONTRACTOR PRIOR TO ANY WORK BEING DONE. ltd LEGEND pholt Macy XXXX FINISH DESIGNATION - REFERENCE (NEW RIBBED ENTRANCE) CARPET 11LE RESET FINISH SCHEDULE --® KEY NOTE DESIGNATION V-4LUXURY STORE NUMBER: 03105 VINYL TILE NEW CARPET TILE AS SCHED. 9870 MAIN ROAD (RETAIL) MATTITUCK, NY 11952 PROJECT TYPE: (72) RESET DRIVE AISLE CARPET TILE CS PROJECT NUMBER: 165265 A B C D E NOTES BY SYMBOL TOILET HALL (� ARCHITECT OF RECORD: 1 DEMOLISH EXISTING INSTALL NEW AS O GCOTORFLASH APATCH EXISTING S11NG RETAIL ATRPET, O 8UTY LVT 100„ 810 „ SHOWN/SCHEDULED. FLOORITRANSING TOM GATE ANYTION OF EXISTING UNEVENNESS NEVE NESS OF _ _ LISH NEW CARPET INSTALLATION. r O ANDOINSTALLI EW LVT ASVCT NSHOWNLLBASE O r SCHEDULED. O7 COORDINATE NEW FLOORING NTH PHARMACY FRONTLINE LAYOUT. I I r VESTIBULE O3 NEW LVT MUST REQUIRE AN RH MOISTURE TEST, RE: LVT MOISTURE O INSTALL NEW CARPET ON TOP OF SBLM r 100 MITIGATION ON SHEET A4. EXISTING LVT. 545 West 45th Street 4th Floor r 10-9 O9 DEMOLISH EXISTING VCT AND WALL BASE New York, NY 10036 WOMEN'S r / ,—, ,—� ,-- � r O4 PATCH CARPET AS GONDOLA MOVES AND INSTALL NEW CERAMIC TILE AND TOILET r /j/ ARE MADE. T: 212.995.5600 F: 212.675.4228 O 108 �� //�/ BASE AS SHOWN SCHEDULED. www.sblm.com 8'-0" 1�5 EXISTING FLOORING/BASE TO REMAIN. 10 COORDINATE NEW FLOORING WITH VACCINATION ROOM; RE:F-1 CONSULTANT ENGINEER BREAKROOM 105D 8,_0 LVT MOISTURE MITIGATION E ®E R�0► FOR QUESTIONS RELATED TO FLOORING INSTALL AND MITIGATION STEPS, PLEASE CONTACT THE PROJECT SPECIFIC NAI VENDOR OR THE BELOW APPROVED INSTALLER: CHECKOUT ENGINEERS ANDREA HAGEMAN MITCHEL FARIA JACK GENCO In •`-Too 102 , „ INSIDE EDGE MATS INC. INTERFACE SERVICES 8345 LENEXA DRIVE, SUITE 300 �,.' .::•::.: 10-8 1 2 aha emonOlecis.com mforta0matslnc.com Jack.GencoCInterface.com .�o$ 9 LENEXA, KS 66214 s51.3ss.4212 781-573-0292 508-523-1859 TEL 913.742.5000 FAX 913.742.5001 RECEIVING NOTE:MIIIGATION AND INSTALLATION ONLY. PRODUCT SUPPLIED BY NAI VENDOR TO GC. AREA lo6A PROCESS: WWW.HENDERSONENGINEERS.COM /. 16 -6 O / /�/.//%/// �„ N GC IS RESPONSIBLE FOR CONCRETE SLAB MOISTURE AND RELATIVE HUMIDITY(RH) TESTING REQUIRED FOR ALL PROJECTS. // / / �6 TESTING BE CONDUCTED IN AREAS WHERE LVT TO BE INSTALLED. MAXIMUM OF 4 PROBES PER TYPICAL • / / /// TO PHOTO LAB LOCATION (LARGER STORES MAY REQUIRE FURTHER PROBES). CONSULTANT. HIGHEST MOISTURE TESTING RESULT FOR THE ENTIRE STORE SHOULD BE USED AS THE BASIS FOR BELOW TO 103 MOISTURE MITIGATION STEPS RELATED ADHESIVE TYPE AND OTHER MITIGATION SELECTION. rFr°O 10'-8 1/2n PRODUCT SPECIFICATIONS OR EQUIVALENT TO BE APPROVED BY SPM FOR ALL PROJECTS. N RH VALUE RANGE FOR LVT: - j/ ��// - - - - - - 2 100%<RH 100%RH ALTERNATIVES /. 1 6' / // /. RETAIL 01 -1 //./ / // 101 7'-1 TAYLOR RESOLUTE /r .......... . . . �// // „ 4 TRAXX100 /./ / %/ 11 -11 SPRAYLOCK 6500 PLATINUM SCHONOX EPA 10 AQUAFl.EX" / // / /. / GENERAL NOTES: • /. /. / / z S / i I EAL / / / / o // / �/�// I 1. PROVIDE TRANSITION STRIP BETWEEN ALL FLOOR TYPES DARC A o // /. /. // N 5 Jl //. // / . // WC;NA T // // / // . P O •o / /. / // ::....:// // / // / FF5 cn :.:.:.:. FF15. _ o z �//////// / Z tS' o :::;:::::. ::::::: � / i i i o 0409 Q /7 O cv a / / / /. / // ,t„oo / O PHARMACY /./ //. //. / // // , // /// // / ./ //. ; S a MANAGER'S 110 / //. / // //./ _ -� _ REVISIONS: _ „ OFFICE 9'-0 ::. : :: o:::: /./ /./ //./ / /// / Z 104 /./ / / / /. ri /. / /. DATE: ISSUE/REVISION: 8 0 1 4 /. / . / 77- /7' // J7 12-16-2022 BID/PERMIT SET / /. / // j/ W / / /./ /. / // o / /. i. ///j j//j///j// /////////// I O w / / / / 1 // // /// ////////// // 0 W 110NDIR LVT ::. _-%///////// / N A4 4L a3z aa� aaz aaa 301 / / . ,' - 4 O WAITING 111 O DRAWING BY: JC CHECKED BY: TL O DATE: 12-16-2022 JOB NUMBER: 022139 TI TLE: FINISH FLOOR PLAN SHEET NUMBER: A4- COMMENTS: IN I LKIUK FINISH SLHLUULL 19'-83" 14'-103" 5�" 11'-Ol" 9'-15" 11'-0i" TAG MATERIAL DESCRIPTION MFR. STYLE CAT. N0. COLOR NOTES 8 29-11 4 8 8 8 / / V.LF. V.I.F. V.I.F. V.I.F. V.LF, V.I.F. V.I.F. ACOUSTICAL o ® CEILING TILE ARMSTRONG CORTEGA 769 WHITE 2x4 PANELS FLOORING I o 0 19DF302500 QUARTER TURN. REFER TO CARPET TILE 1m ® ® 6 YP ® V� V' u ® � MODULAR CARPET INTERFACE CUSTOM GREY #180527 SPEC. 19DF302500 QUARTER TURN. REFER TO CARPET TILE L _ r r r — — — — — Yl G 5G iG �- w / / / T - - - - - - - � r � � w ® MODULAR CARPET INTERFACE BLACK #180668 CUSTOM SPEC. MODULAR CARPET > "� > AC I DO NOT PAINT BEHIND I I \\ I = I = ® (CUSHION-BACK) INTERFACE 242847 BLACK #180668 INSTALL WITH RANDOM PATTERN \ \ WALL FIXTURES. \ \ \ \ `� \ \ \ \ \ \ \ \ w �' > �\ �\ p I I I I I in = ® RUBBER WALL BASE BURKE MERCER THERMOPLASTIC 4GL COVE - r r COORDINATE WITH FINAL 00 WAL IN C OLER UBBER(TP):GROUP 1(SOLID \ \ I RCHANDISE PLAN FOR I I / I Uj 701 BLACK RESET / i i ( 1 I / I X ® ENTRANCE CARPET TILE INTERFACE SR999 104945 ONYX REFER TO CARPET TILE SPEC. \ \ ACCURATE GONDOLA / � STORE NUMBER: 03105 x x x � � � / / � � � � � � � � i � i LOCATION (TYP.). I I / / / i i y y'� I NATURAL A00211 WASHED RUN PERPENDICULAR TO DRIVE AISLE. 10 ® LUXURY VINYL FLOORING INTERFACE WOODGRAINS MAPLE REFER TO RESILIENT TILE SPEC. FF16 COKE FLM PEPSI FLM ACROVYN CANDY-1ADA CHECKOUT-1CHECKOUT-J""" HECKOUT ADA PHOTOLAB WALL FIXTURES (TYP.) ATM FF16 9 DOOR WALK-IN FF16 CERAMIC TILE 9870 MAIN ROAD 1 RIGHT ELEVATION WALL COUNTER ® COUNTER ® COUNTER RE:MERCHANDISE PLAN COOLER CERAMIC TILE VOL. 1 DALTILE CONTACT: DEGREES SILVER COVE BASE 6x12. LATRICRETE 24 MATTITUCK, NY 11952 ® (877) 556-5728 VL71 NATURAL GREY NON SANDED GROUT PROJECT TYPE: (72) RESET A5 3/16" _ '1'-0" DALTILE CONTACT: CENERE FOG FLOOR TILE 12x12. LATICRETE 24 ® CERAMIC TILE (877) 556-5728 SEVERING SV98 NATURAL GREY NON SANDED GROUT LAMINATE CS PROJECT NUMBER: 165265 El LAMINATE (MILLWORK) WILSONART 10734-60 LIMBER MAPLE INSTALLATION: WILL BE USED WITH 27'-43" 10'-31" C-73" 10'-3i" 43" „ 3'-71" 6'-51" 7'-103" VERTICAL AND HORIZONTAL SURFACES 4 8 4 8 30-1 4 2 4 PAINTS SEALANTS ARCHITECT OF RECORD V.I.F. V.I.F. V.I.F. V.I.F. V.I.F. V.I.F. ANGLED V.I.F. V.11 F. ® ATRIUM WHITE/AKA ECO SPEC 374, 2 COATS, WALL TRIM PAINT BENJAMIN MOORE OC-145 J ALABASTER PAINT, EGGSHELL FINISH BENJAMIN MOORE TINTED WINDS PAINT/PRIMER-2 COATS WILL ACCEPT WAL ® PAINT/PRIMER AQUA LOCK PLUS 981 BREATH VINYL, LEVEL 5 FINISH REQUIRED ' ® 6 3 O ® ® PAINT BENJAMIN MOORE 779 FAIRVIEW BLUE ECO SPEC PAINT374?EGGSHOA , WAL/TRIM Qlk r - - - - - - - - - - - - - - - - - - - - - - - - 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ® PAINT BENJAMIN MOORE 2001-10 RUBY RED ECO SPEC 374, 2 COATS, WALL/TRIM - - - - - - SBL T '-�: =i ,.,_ � � r -` -� - - - - - - - - - - - - - - - - - - - �' - - - _ - -- - - - - - - - - - - - - - - - - -� - - _ - - - - - - - - - - - - - - --- - - r ® STAIN MINWAX WOOD FINISH PICKLED OAK PAINT,2 COATSFLAT FINISH 545 West 45th Street M > > I I DO NOT PAINT BEHIND I " o_ I � I _ t et 4th Floor W ,�, w w DO NOT PAINT BEHIND o > COROTECH HIGH PERFORMANCE New York NY 10036 o z o MATCH ATRIUM WHIT I WALL FIXTURES. 1 2 ¢ I I ¢ WALL FIXTURES. FP EPDXY BENJAMIN MOORE V342 PRE-CATALYZED WATERBORNE EPDXY, , LU 1 w 7b w I wEi A.K.A. ALABASTER EGGSHELL FINISH. GC TO REPAINT w COORDINATE WITH FINAL I I = I I = 7� of COORDINATE WITH FINAL i 1 I T: 212.995.5600 F: 212.675.4228 C.0 co in RESTROOM WALLS. MERCHANDISE PLAN FOR I o I o MERCHANDISE PLAN FOR I I I I www.sblm.com x ACCURATE GONDOLA �- E U- ACCURATE GONDOLA I I I I ® PAINT PROWALL - - RESTROOM FRP RESTORATION w I LOCATION (TYP.). WALL COVERING LOCATION (TYP.). I FF16 WALL FIXTURES (TYP.) WALL FIXTURES (TYP.) FF16 W15 CLEAR ACRYLIC CORNER GUARD TRIMACO WALL COVERING TRIM CLEAR 1 , 8"X 1 1 8" X 8FT CONSULTANT ENGINEER' RE:MERCHANDISE PLAN RE:MERCHANDISE PLAN GENERAL FINISHES NOTES: 2 FRONT ELEVATION 1. ALL FINISHES SHALL BE PROVIDED AND INSTALLED AS PART OF THIS CONTRACT UNLESS OTHERWISE NOTED. 2. THE CONTRACTOR SHALL INSTALL ALL REQUIRED NON-COMBUSTIBLE BLOCKING AS REQUIRED FOR THE INSTALLATION OF ALL MILLWORK �� � AND TOILET ROOM ACCESSORIES. COORDINATE WITH EQUIPMENT SUPPLIERS. A5 3/16" _ '1'-0" 3. ALL INTERIOR FINISHES SHALL CONFORM TO A MAXIMUM CLASS A FLAME SPREAD RATING AND A SMOKE DEVELOPED INDEX OF 450. 4. ACOUSTICAL CEILINGS AND INSULATION SHALL HAVE A MAX SPREAD OF 25 AND A MAX SMOKE DEVELOPED INDEX OF 50. ENGINEERS 5. WHERE APPLICABLE, TOOTH IN NEW FLOOR TILES WITH EXISTING FLOORING TO MATCH EXISTING PATTERN. IV 6. REPLACE ALL LAMINATE DOORS WITH WOOD DOORS STAINED PT25. 8345 LENEXA DRIVE, SUITE 300 7,_63„ 7'-115" 12'-63" 7'-118" „ 11'-91" 4'-93" 11'-91" S-4j" LENEXA, KS 66214 4 8 8 8 13-0 4 8 4400, ROOM FINISH SCHEDULE TEL 913.742.5000 FAX 913.742.5001 V.I.F. V.I.F. V.I.F. V.I.F. L, J V.I.F. V.I.F. V.I.F. V.I.F. WALLS - RE: NOTE 1 LO L, ¢�'' ROOM NAME CEIL. WM.HENDERSONENGINEERS.COM Z) U> 1 2 3 4 FLR BASE CEIL HGT. REMARKS LI 100 ENTRANCE ®2 720 ®0 — FF-F-20-1 rFF16 XIS 10'-9"(V.I.F.) w ® 10'-9" - 11 -11" w v w * FF21 AT COOLERS AND Al AT C) PT24 �j`� `� z U 7� 101 RETAIL ®0 ® ® ® F16 XI N > a w ® © 4 nhW 11 �� I PT24 "o > > ® 6 YP. 3 C �� * _ — — ® (V.I.F.) BEAUTY CONSULTANT' J 1�Y/ 2 102 CHECKOUT ® ® ® IS 10'-9" (V.I.F.) I Oak� mnadmm 103 PHOTOLAB* ® ® — ® ® ® ® 10'-9" (V.I.F.) � = PT20 6UNDERSIDE _ _ _ _ _ _ _ _ _ _ I- - - - - - - - - - - - - - - - - - - - - - - - - - 7 I- LL: PHARMACY OF VALANCE 1 I I ! > 104 MANAGER'S OFFICE XI XI XIS ® ® XI 8'-0 1/4" (V.I.F.) b > = 5 b DO NOT PAINT BEHIND I 00 NOT PAINT BEHIND o _ � BEYOND:EM i WALL FIXTURES. I I = WALL FIXTURES. i I ( 105 EMPLOYEE LOUNGE ® ® ® ® ® ®1 EXTSI 8'-0" (V.I.F.) v 00 COORDINATE WITH FINAL I I Uj COORDINATE WITH FINAL 'oo I I 106 RECEIVING ® ® ® X S EX-IST ® ® 16'-6" (V.I.F.) Q MERCHANDISE PLAN FOR MERCHANDISE PLAN FOR Q \ (EXIST.) (EXIST.) (EXIST.) I I ACCURATE GONDOLA I I CLEAN EXIST RP. > (EXIST.) 32" 3s" U ACCURATE GONDOLA I 107 UNISEX REST ROOM ® ® ® ® ® ® ®1 8'-0" (V.I.F.) REPAINT WITH PRO-WALL. AREA AREA DROP-OFF DROP-OFF LOCATION (TYP.). l LOCATION (TYP.). I I CLEAN EXIST FRP. AREA AREA 108 UNISEX REST ROOM ® ® ® EM ® ® 11 8'-0" (V'I'F') REPAINT WITH PRO-WALL. FF16 FF16 WALL FIXTURES (TYP.) FF16 FF16 WALL FIXTURES (TYP.) FF16 109 HALL ® ® ® ® ® ® � 8'-0" (V.I.F.) PT20 ABOVE FRP. RE:MERCHANDISE PLAN RE:MERCHANDISE PLAN 110 PHARMACY* ® ® ® ® =—F®— ® W-O" (V.I.F.) * REFER TO INTERIOR ELEVATIONS SHEETS 3 SEAL: REAR, ELEVATI FINISH NOTES: 1. WALLS ARE NUMBERED STARLING WITH THE FRONT WALL AS #1, AND THEN ROTATE COUNTER CLOCKWISE. SEAL 2. ALL EXISTING METAL DOORS AND FRAMES TO BE REPAINTED TO MATCH WALLS.A5 ,��RED 3/16" = 1'-0" 3. BACK OF PHARMACY VALANCE TO BE PAINTED 4. FRONT AND UNDERSIDE OF PHARMACY VALANCE TO BE PAINTED® MICHAF� y0 0 5. GC TO CONFIRM PLACEMENT OF PIN LETTERS PRIOR TO INSTALLATION WITH CVS PROJECT MANAGER ON SITE. p .o A 6. INSTALL NEW 1"X1"X48" CLEAR ACRYLIC CORNER GUARD ON ALL NEW EXPOSED CORNERS IN SPACE 7. CLEAN WINDOWS, MIRRORS, LENS COVERS, HVAC SUPPLY AND RETURN DIFFUSERS AND COOLER EXTERIORS AND TOPS. 8. ALL EXISTING WOOD DOORS TO BE CLEANED. �. 7'-10" 10'-102„ 57„ 3,_38„ 4,_4 11 $„ 3,_3 1. $„ 8'-4„ 5,-68„ le 7,_2" 9'-10" 16'-44„ 5,_98„ 9,_24„ 12'-0" 15-3„ V.I.F. V.I.F. V.I.FT V.I.F. I V.I.F. I V.I.F. I V.I.F. V.I.F. V.I.F. V.I.F. V.I.F. V.I.F. 10 0409 w LL z Li lc- o EQ EQ I _ ¢ v P 0 ® 0 Ca 0 ^ ® 1 ODDS 11 S �J 6 TYP. I lJ l'�lJ IJ �J ® T 4 > REVISIONS: - - - - - - -- - - - - - - - 8 - - - - -- - � (- - - - - - - - - - - - -- - _- - - - - - - - - - - - - - - - - = DATE: ISSUE/REVISION: w 2 I- - - - - - - - \ C3 I DO NOT PAINT BEHIND / DO NOT PAINT BEHIND I \ I DO NOT PAINT BEHIND s _ m WALL FIXTURES. /� '\ �// WALL FIXTURES. I \ I CO w WALL FIXTURES. co w o� o _,,_ 12-16-2022 BID/PERMIT SET COORDINATE WITH FINAL I I I I co COORDINATE WITH FINAL 00 `D w COORDINATE WITH FINAL 7b VACCINE SUITE(RTC) © U- i o MERCHANDISE PLAN FOR / \ MERCHANDISE PLAN FOR l U I MERCHANDISE PLAN FOR SUITE#1 �r, '` r '� ¢ ACCURATE GONDOLA /�� %� \% /// ACCURATE GONDOLA I I X ACCURATE GONDOLA a LOCATION (TYP.). LOCATION (TYP.). 1 L` LOCATION (TYP.). C5 FIRE (-F16 WALL FIXTURES (TYP.) ICE FREEZER FREEZER FIRE FF16 WALL FIXTURES (TYP.) FFF16 FF16 FF16 EXTINGUISHER RE:MERCHANDISE PLAN EXTINGUISHER RE:MERCHANDISE PLAN 4 LEFT ELEVATION A5 3/16" = V-0" DRAWING BY: JC CHECKED BY: TL 6 YP. photo studio 7 5' CD ,� -101" DATE: 12-16-2022 flck"+aW"kiMh camter r LZ cj >w JOB NUMBER: 022139 F o j > ® i LL ci ur,r a W a LE. WT Y r ; LL ,R `o ¢ F \ I o 3 INTERIOR ELEVATIONS ADA PHOTOLAB PHOTO SERVICES NOTES BY SYMBOL SHEET NUMBER: FF16 COUNTER 3 PANEL 1G) REPAINT DOOR AND FRAME PT20 . Q NEW PRIVACY PANELS 5 PH01"0 LAB ELEVATION 6 RX WAITING ELEVATION Q REPAINT DOOR FRAME PT20 . Q PATCH/PAINT AS SHOWN/SCHEDULED. A5 A5 3/16" = 1'-0" A5 3/16" = 1'-0" INSTALL NEW BLACK PIN LETTERS, AS SHOWN. (D NEW PHOTO LAB HANGING SIGN. COMMENTS: INSTALL NEW WHITE PIN LETTERS, AS SHOWN. Q RX DIGITAL SCREEN; RE: 1 & 2/ A7 EMPLOYEE SIDE EMPLOYEE SIDE NEW COUNTER AND 3'-0" POINT-OF-SALE CABINET, TYP. CLR EMPLOYEE SIDE EQUIPMENT EMPLOYEE SIDE NEW RISER NEW REGISTER MONITOR (RELO) ISA SIGNAGE SHELF ON NEW SWING ARM MOUNTED ON MAGAZINE <: > IIL_j CLEAR COUNTER SPACE RELO REGISTER MONITOR 3'-0" MIN RACK TO IDENTIFY AT TRANSACTION AREA ON NEW SWING ARM ______ _ ___ ____r ACCESSIBLE CHECKOUT maclylu O— – – _ 3'-0" CLR MIN PhQu Z Oiria ii COUNTER SPACE MAGAZINE I 3'-0" MIN MAG RACK, TYP. o OPS RACK POS 11 I XEARSPA SCREENRESET CREDIT STORE NUMBER: 03105 CARD9870 MAIN ROAD READERII _ N EAR SPA a I =_ _�• • I - 6 I �, I I g CLEAR FLOOR SPACE 10'-4" RE: MERCHANDISE PLAN MATTITUCK, NY 11952 A6 I RELOCATED CREDIT A6 FOR ACCESSIBLE CARD READER I ( � o- I I FORWARD APPROACH a PROJECT TYPE: (72) RESET - - - - - - - - - I As I N I I N in 4'-0" 4'-0" CLEAR FLOOR SPACE L 2._6.. RETAIL SIDE A6 FOR ACCESSIBLE SIDE – – – –TYP– – – – -- CS PROJECT NUMBER: 165265 APPROACH RETAIL SIDE ADA PHARMACY RETAIL SIDE ADA FRONT CHECKOUT 1 ADA FRONT CHECKOUT COUNTER 2 ADA PHARMACY PICKUP 3 DROP-OFF COUNTER 5 ADA PHOTOLAB COUNTER s COUNTER ELEVATION ARCHITECT OF RECORD A6 SCALE: 1/2" = 1'-0" A6 SCALE: 1/2" = 1'-0" A6 SCALE: 1/2" = 1'-0" A6 SCALE: 1/2" = 1'-0" A6 SCALE: 1/2" = 1'-0" DIGITAL ORDER CUSTOMER CARD READER STATIONS & SCANNER IN FOREGROUND SBLM CENTERED BETWEEN 545 West 45th Street 4th Floor END PANELS NEW RISER SHELF New York, NY 10036 CREDIT CARD READER 4° REGISTER T: 212.995.5600 F: 212.675.4228 S-O" CLR 14 < f \ MONITOR ON www.sblm.com 12 ADJACENT FIXTURES f NEW SWING ARM A6 ISA GRAPHIC ON � DROP OFF SPACE G4 UNIT G4 UNIT A6 CHECKOUT TOP � � `� \ IOU BOTH SIDE PANELS – – o o CHECKOUT — CONSULTANT ENGINEER' OF 36 WIDE 13 S N I 1 , Of 3'-O" CLR MIN COUNTER a6 EMPLOYEE ----i r I COUNTER TOP `�\ 1 RETAIL SIDE00 w I SIDE Of COUNTER SPACE DROP-OFF COUNTER Z a i fin) rill nl END PANEL Q coui `D o `� a I11� III BEYOND M o IDERSON BAGWELL ' T III II L II 0 ENGINEERS N m cV i IIIL1 J��III p Q Q III I I �I III N 8345 LENEXA DRIVE, SUITE 300 FFL I�� — `—� — TEL 913.74250 0 ' FAX 913.742.5001 (V N 30 MIN KS 66214 L30 MIN 30 MIN FRONT EDGE OF TRANSACTION MERCHANDISE AREA, ALIGN WWW,HENDERSONENGINEER$.COM i i �� MERCHANDISE AREA ALIGN FRONT EDGE OF TRANSACTION CLEAR CLEAR Al CLEAR COUNTERTOP WITH FRONT PLANE COUNTERTOP WITH FRONT PLANE FFL10'-4" RE: MERCHANDISE PLAN OF MERCHANDISE AND VERTICAL OF MERCHANDISE AND VERTICAL SUPPORTS SUPPORTS ADA PHARMACY PICK UP ADA PHARMACY DROP-OFF ADA PHOTOLAB ADA FRONT CHECKOUTADA PHARMACY PICK UP CONSULTANT: 7 COUNTER ELEVATION s COUNTER ELEVATION 10 COUNTER ELEVATION 11 COUNTER SECTION 12 COUNTER SECTION A6 SC= = — A6 SCALE: 1/2" = 1'-0" A6 SCALE: 1/2" = 1'-0" SCALE: 1/2" _ 10" A6 SCALE: 1/2" = 1'-0" A6 ISA SIGNAGE MOUNTED ON EQ EQ END PANEL COUNTER � MOUNTING SURFACE , HINGE o' J i\\ RETAIL SIDE MOUNTING BRACKET SEAL p _ 5 BRED ARc � END PANEL ® C3' z – FIRE EXTINGUISHER y BEYOND o I 19 rl _ NOTE: 5 MICHgF� X I COORDINATE FIRE � OSP EMPLOYEE SIDE RETAIL w –� EXTINGUISHER �� �N SIDE o LOCATIONS WITH /r- % \ z �� � Of < z X =_ DIRECTIVES OF LOCAL WAITING '` �N __jo p �/ \ _ p o a FIRE MARSHAL. IF ® r' o / \ co w i LL -�/ / �� I\ '�' w ' �' ALTERNATE LOCATION I1 N z N p // �\ /� cV Y N w o w IS DIRECTED BY LOCAL z C., // '- Q o AUTHORITY, VERIFY T FFL ` �� – �� 30"X48" CLEAR FLOOR – 6" MAX. " MIN p SPACE IS LOCATED FINISH FFL i 0 % IMMEDIATELY ADJACENT FLOOR 19 N m TO EXTINGUISHER. ACCESSIBLE REVISIONS: KNEE CLR WAITING SIGN KNEECLR'O' upm/ DATE: ISSUE/REVISION: ADA PHARMACY ADA PHOTO LAB ACCESSIBLE 12-16-2022 BID/PERMIT SET 13 COUNTER SECTION - TYP. 14 COUNTER SECTION 15 FIRE EXTINGUISHER DETAIL 16 WAITING SIGN A6 SCALE: 1/2" = 1'-0" A6 SCALE: 1/2" = 1'-0" A6 SCALE: 1/2" = 1'-0" A6 SCALE: 1/2" = 1'-0" i 40"' CANE WITHOUT SIDE TO REAR WALL TOUCH PROTECTION 18"_19" 24" LI 1 " APRON � 15" MIN 5" MAX .8 12 °OXof 11 0 z c 1�"MIN o m DRAWING BY: JC ADA ;� cn rn ;� _ �* _i _i �n 00t M N M O ( N � l< _ N M o CLR M O 01bFINISHED '- \ N FLOOR WATER COOLER �Cr 8"%MIN TOILET % WATER CLOSET AND WATER CLOSET " GRAB BARS bit CHECKED BY: TL MAX SEAT TOILET TISSUE AND GRAB 16 MIN SECTION AT LOW COVER DISPENSER BAR 8" WATER COOLER DISPENSER , DATE: 12-16-2022 TABLE IN - JOB NUMBER: 022139 OPEN POSITION ° , KNEE/TOE 20" CLEARANCE TITLE: o TO REAR WALL `D SEE O c w _ J Q _ _ GENERAL m Q Q ACCESSIBLE DETAILS 0 0 o Lj. Q o < ;!, M NOTES 15„ o i\ p N N = a° o MIN a "' "' `- N FINISHED N �, — SHEET NUMBER: FLOOR SAP HAND WASTE FEMININE WASTE BABY CHANGING COAT COAT RACKS LAVATORY AND 8" MIN DISPENSER DRYER RECEPTACLE RECEPTACLE STATION HOOK MIRROR UNIT 10 A6 11" 6° MIN MAX COMMENTS: rl 7 ACCESSIBLE MOUNTING HEIGHTS NOTES: - ALL MOUNTING HEIGHT DIMENSIONS ARE TO TOP OR BOTTOM OF ACCESSORY, UNLESS OTHERWISE NOTED. A6 SCALE: 1/4" = 1"0" - REFER TO PLANS/ELEVATIONS FOR SITE SPECIFIC INFORMATION ON FIXTURES AND ACCESSORIES. 1.25" (31mm) PRN 43" LED TV MOUNT, 30.87" TOILET ROOM ACCESSORY SCHEDULE REFER TO FIXTURE SCHEDULE (7$d 7" 0.42" MEN WOMAN METAL STUDS ® 16 OC = W I ... )11mm\\ a ..: n o v v v v v v o v v v ( ) 0_45" Z N Q Z N Q �.' .• 7» ELECTRIC JUNCTION BOXES TO BE 3 Q o J U J O 8 BELOW TOP OF TV, RE: ELECTRICAL $ " 29.38" o Q o 5 5 9.15 6.03" 746mm 815 (21mm) ACCESSORY o Li W o o Uj z M DEL NUMBER rim 5/8" PLYWOOD BACKING SPANNED (232mrn} (153mm} { ) (207mm) 16.$9" TOILET PAPER HOLDER ® ® BRADLEY 5126 EVENLY ABOVE METAL STUDS, _ (429mm) TOILET SEAT COVERphcxlrmacylm ATTACHED WITH LAG BOLTS UT PLYWOOD BACKING DOWN SO IT 2.00"� 16.00" v 1.00" DISPENSER ® ® TOUGH GUY 2VEX8 IS CONCEALED BEHIND TV ONCE I (� I "'o (51 mm) (406mm} (2Smm} 42" GRAB BAR ® ® BRADLEY 8120-001420L ATTACHED. PLYWOOD BACKING TO 42" GRAB BAR ® ® RESET PHILIPS 58BFL2114 — — - — ADAPTOR BRACKET BRADLEY 8120-001 60 E CENTERED ON THE WIDTH OF TV o �� _ _ _ �� WALL PLATE POWER: AC 120-240V, 50-60Hz BEHIND MOUNTING BRACKET I r:,o 18" GRAB BAR ® ® BRADLEY 8120-001180 DIMENSION`, (W x H x D): 51.26 x 29.92 x 3.19/3.39 INCH 2"X4" WOOD STUD BLOCKING (.,� 2,67" 18" X 36" MIRROR ® ® BRADLEY 781-1836 STORE NUMBER: 03105 CAPABLE OF SUPPORTING A ; ', I:`- ';: ' WEIGHT /LB : 33.29 LB l;.1::> . ':;;" s 1 31.26"' (67mm} SOAP DISPENSER ® ® GOJO 5W626 l ) CONCENTRATED LOAD OF 250 fi ,:;.:;::: :; ; POUNDS, GC TO PROVIDE .:'� " ;' J. 4.54" (794mm) 5.40" HAND DRYER � ``::;` �. :: (115mm) 29.21" (137mm) ® ® BRADLEY 2902-2800, 9870 MAIN ROAD 110/120V ELECTRICAL EQUIPMENT (742mm) WASTE RECEPTACLE ® ® BOBRICK B-279 MATTITUCK, NY 11952 5/8" GYB BOARD BEHIND PLYWOOD EQ EQ MAX o FEMININE NAPKIN ® ® GRAINGER 1ECK9 PROJECTTYPE: (72) RESET BACKING a • WASTE RECEPTACLE -GC TO CONFIRM BLOCKING MOUNTING HEIGHT/SPACING AND JUNCTION BOXES WITH MOUNTING 1.13" 15 95" PAPER TOWEL ® ® N/A BRACKET. REFER TO ELEVATIONS FOR TV HEIGHTS. .75" (2smm) (405mm) BABY CHANGING STATION ® ® RUBBERMAID 7818-88 CS PROJECT NUMBER 165265 -FOR EXISTING CONDITIONS OR EXTERIOR WALLS, GC TO OPEN WALL, VERIFY STRUCTURE, AND {19mm) MAX HOOKS ® O BRADLEY 9114 PROCEED ACCORDINGLY TO POTENTIAL UNFORESEEN CONDITIONS WITH NECESSARY BLOCKING Q e p CAPABLE OF SUPPORTING A CONCENTRATED LOAD OF 250 POUNDS. O o DOOR CLOSER ® ® DORMA 8616 ARP SNB1 -TV'S LESS THAN 80"AFF ARE TO NOT PROTRUDE MORE THAN 4" TO SATISFY ADA REQS. FRONT VIEW sioE VIEW (NO SUBSTITUTE ARCHITECT OF RECORD' RESTROOM SIGNAGE ® ® UNISEX ISA GRAPHIC +1501.50 TUT 'TYPICAL TV MOUNTING PLYWOOD TYPICAL TV & MOUNTING BRACKET REFER TO 17 A6 & ELEVATIONS FOR FIXTURE MOUNTING HEIGHTS AND LOCATIONSsprk9 1 BACKING DETAIL FOR NEW CONSTRUCTION 2 REFERENCE DETAILS A7 `.KALE: N.T.S A7 SCALE: N.T.S SBLM 545 West 45th Street 4th Floor TV. INSTALLATION NOTES: New York, NY 10036 • 5/8" PLYWOOD (MINIMUM OF 10.25" TALL, FULL WIDTH OF TV) BACKING SPANNED EVENLY ABOVE METAL STUDS, ATTACHED WITH LAG BOLTS T: 212.995.5600 F: 212.675.4228 • CUT PLYWOOD BACKING DOWN SO IT IS CONCEALED BEHIND TV ONCE ATTACHED. PLYWOOD BACKING TO BE CENTERED ON www.sblm.com THE WIDTH OF TV BEHIND MOUNTING BRACKET • (QTY - 2) 2"X4" WOOD STUD BLOCKING CAPABLE OF SUPPORTING A CONCENTRATED LOAD OF 250 POUNDS, GC TO PROVIDE, PLACED IN WALL CAVITY 10.75" BELOW TOP OF TV MOUNTING HEIGHT AND FINISHING 4.75" BEFORE BOTTOM OF TV • 5/8" GYB BOARD BEHIND PLYWOOD BACKING CONSULTANT ENGINEER: • GC TO CONFIRM BLOCKING MOUNTING HEIGHT/SPACING AND JUNCTION BOXES WITH MOUNTING BRACKET. MOUNT TV 4'-4" AFF, Mount PLYWOOD BLOCKING 4' - 6.75" AFF • FOR EXISTING CONDITIONS OR EXTERIOR WALLS, GC TO OPEN WALL, VERIFY STRUCTURE, AND PROCEED ACCORDINGLY TO POTENTIAL UNFORESEEN CONDITIONS WITH NECESSARY BLOCKING CAPABLE OF SUPPORTING A CONCENTRATED LOAD OF 250 IHENDE SO POUNDS. • TV's LESS THAN 80"AFF ARE TO NOT PROTRUDE MORE THAN 4" TO SATISFY ADA REQUIREMENTS FOR PROTRUDING OBJECT ENGINEERS 8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 TEL 913.742.5000 FAX 913.742.5001 WWW.HENDERSONENGINEERS.COM CONSULTANT-. SEAL: '(ERE ARC MICHgF4 4 A LOP Q� REVISIONS: DATE: ISSUE/REVISION: 12-16-2022 BID/PERMIT SET DRAWING BY: JC CHECKED BY: TL DATE: 12-16-2022 JOB NUMBER: 022139 TI TLE: SCHEDULES, NOTES & DETAILS SHEET NUMBER: A7 COMMENTS: SECTION 26.05.05 C. MC CABLE FITTINGS: 4. FOR NON-EMERGENCY (NON-LIFE SAFETY & NON-CRITICAL) CIRCUITS IN GENERAL PATIENT FOOTINGS AND GRADE BEAMS, WITHOUT APPROVAL OF STRUCTURAL ENGINEER. SELECTIVE DEMOLITION FOR ELECTRICAL 1. MANUFACTURER & MODEL: AREAS I.E. PATIENT BEDROOMS, EXAMINING ROOMS, TREATMENT ROOMS, CLINICS, AND SIMILAR PART 1 PRODUCTS 2. MAKE PENETRATIONS PERPENDICULAR TO SURFACES UNLESS OTHERWISE INDICATED. a. ARLINGTON (4010 AST SNAP-IN TYPE): (SG38 SADDLE TYPE) AREAS WITHIN HEALTH CARE FACILITIES INCLUDING BUT NOT LIMITED TO, HOSPITALS, NURSING 1.01 CONDUIT APPLICATIONS 3. PROVIDE SLEEVES FOR PENETRATIONS AS INDICATED OR AS REQUIRED TO FACILITATE PART 1 EXECUTION b. CROUSE-HINDS (QLK QUICK-LOK SERIES, SADDLE TYPE); ACB SERIES; SET-SCREW, HOMES, LIMITED CARE FACILITIES, CLINICS, MEDICAL AND DENTAL OFFICES, AND AMBULATORY A. DO NOT USE CONDUIT AND ASSOCIATED FITTINGS FOR APPLICATIONS OTHER THAN AS INSTALLATION. SET SLEEVES FLUSH WITH EXPOSED SURFACES UNLESS OTHERWISE INDICATED `" 1.01 EXAMINATION SADDLE TYPE) CARE CENTERS, WHETHER PERMANENT OR MOVABLE. PERMITTED BY NFPA 70 AND PRODUCT LISTING. OR REQUIRED. '1:. ,, ,., " A. VERIFY THAT ABANDONED WIRING AND EQUIPMENT SERVE ONLY ABANDONED FACILITIES. c. 0_Z GEDNEY (AMC_50 SPEED_LOK, SADDLE TYPE) a. THIS FURTHER APPLIES TO ANY AREA WHERE IT IS INTENDED THAT THE PATIENT WILL B. UNLESS OTHERWISE INDICATED AND WHERE NOT OTHERWISE RESTRICTED, USE THE CONDUIT 4. CONCEAL BENDS FOR CONDUIT RISERS EMERGING ABOVE GROUND. ,;:. B. BEGINNING OF DEMOLITION MEANS INSTALLER ACCEPTS EXISTING CONDITIONS. COME IN CONTACT WITH ORDINARY APPLIANCES SUCH AS A NURSE CALL SYSTEM, TYPES INDICATED FOR THE SPECIFIED APPLICATIONS. WHERE MORE THAN ONE LISTED 5. SEAL INTERIOR OF CONDUITS ENTERING THE BUILDING FROM UNDERGROUND AT FIRST 1.02 PREPARATION d. THOMAS & BETTS (XC_730 SERIES CABLE-LOK, SADDLE TYPE); 300 SERIES TITE-BITE). ELECTRIC INSTRUMENT, CORD CONNECTED EQUIPMENT, ELECTRIC BEDS, EXAMINING LAMPS, APPLICATION APPLIES, COMPLY WITH THE MOST RESTRICTIVE REQUIREMENTS. WHERE CONDUIT ACCESSIBLE POINT TO PREVENT ENTRY OF MOISTURE AND GASES. A. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, = 2. FITTINGS USED FOR CONNECTING TYPE MC CABLE TO BOXES, CABINETS, OR OTHER COORS, AND CEILINGS TO BE REMOVED. EQUIPMENT SHALL BE UL LISTED AND IDENTIFIED FOR SUCH USE WITH AN MCI-A MARKING TELEPHONES, AND ENTERTAINMENT DEVICES. TYPE FOR A PARTICULAR APPLICATION IS NOT SPECIFIED, USE GALVANIZED STEEL RIGID 6. WHERE CONDUITS PENETRATE WATERPROOF MEMBRANE, SEAL AS REQUIRED TO MAINTAIN B. COORDINATE UTILITY SERVICE OUTAGES WITH UTILITY COMPANY. b. TYPE MC- HCF HEALTH CARE FACILITY CABLE IS PERMITTED FOR USE IN GENERAL METAL CONDUIT. INTEGRITY OF MEMBRANE. P%ha"macy'm ON THE FITTING CARTON OR PACKAGE. PATIENT CARE AREAS OF HEALTH CARE FACILITIES. THE USE OF STANDARD/NON-HEALTH C. PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE 3. FITTINGS SHALL BE INSULATED TYPE NOT REQUIRING THE USE OF ANTI-SHORT BUSHINGS. / C. CONCEALED WITHIN MASONRY WALLS: USE GALVANIZED STEEL RIGID METAL CONDUIT, 7. MAKE PENETRATIONS FOR ROOF-MOUNTED EQUIPMENT WITHIN ASSOCIATED EQUIPMENT v � DURING CONSTRUCTION. WHEN WORK MUST BE PERFORMED ON ENERGIZED EQUIPMENT OR 4. ROMEX STYLE, CLAMP TYPE FITTINGS ARE NOT ACCEPTABLE. CARE FACILITY TYPE MC OR AC CABLE IS NOT PERMITTED IN PATIENT CARE AREAS INTERMEDIATE METAL CONDUIT (IMC), OR ELECTRICAL METALLIC TUBING (EMT). OPENINGS AND CURBS WHERE POSSIBLE TO MINIMIZE ROOFING SYSTEM PENETRATIONS. WHERE CIRCUITS, USE PERSONNEL EXPERIENCED IN SUCH OPERATIONS. D. CONCEALED WITHIN HOLLOW STUD WALLS: USE GALVANIZED STEEL RIGID METAL CONDUIT, PENETRATIONS ARE NECESSARY, SEAL AS INDICATED OR AS REQUIRED TO PRESERVE 1.06 D. EXISTING ELECTRICAL SERVICE: MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS WIRING CONNECTORS SECTION 26.05.26 INTERMEDIATE METAL CONDUIT (IMC), OR ELECTRICAL METALLIC TUBING (EMT). INTEGRITY OF ROOFING SYSTEM AND MAINTAIN ROOF WARRANTY. INCLUDE PROPOSED Reset + Rx Di Ital C COMPLETE AND READY FOR SERVICE. DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND A. DESCRIPTION: WIRING CONNECTORS APPROPRIATE FOR THE APPLICATION, SUITABLE FOR USE GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS E. CONCEALED ABOVE ACCESSIBLE CEILINGS: USE GALVANIZED STEEL RIGID METAL CONDUIT, LOCATIONS OF PENETRATIONS AND METHODS FOR SEALING WITH SUBMITTALS. Steen WITH THE CONDUCTORS TO BE CONNECTED AND LISTED AS COMPLYING WITH UL 486A-4868 (EMT). Expansion + P oto CONNECTIONS. MINIMIZE OUTAGE DURATION. INTERMEDIATE METAL CONDUIT IMC OR ELECTRICAL METALLIC TUBING EMT . 8. INSTALL FIRESTOPPING TO PRESERVE FIRE RESISTANCE RATING OF PARTITIONS AND OTHER 1.03 DEMOLITION AND EXTENSION OF EXISTING ELECTRICAL WORK OR UL 486C AS APPLICABLE. (IMC), B. WIRING CONNECTORS FOR SPLICES AND TAPS: PART 1 PRODUCTS F. INTERIOR, DAMP OR WET LOCATIONS: USE GALVANIZED STEEL RIGID METAL CONDUIT. ELEMENTS, USING MATERIALS AND METHODS SPECIFIED IN SECTION 07.84.00. A. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW 1. COPPER CONDUCTORS SIZE 8 AWG AND SMALLER: USE TWIST-ON INSULATED SPRING 1.01 GROUNDING AND BONDING REQUIREMENTS G. EXPOSED, INTERIOR, NOT SUBJECT TO PHYSICAL DAMAGE: USE GALVANIZED STEEL RIGID I. CONDUIT MOVEMENT PROVISIONS: WHERE CONDUITS ARE SUBJECT TO MOVEMENT, PROVIDE STORE NUMBER: 3105 CONSTRUCTION. CONNECTORS. A. EXISTING WORK: WHERE EXISTING GROUNDING AND BONDING SYSTEM COMPONENTS ARE METAL CONDUIT, INTERMEDIATE METAL CONDUIT (IMC), OR ELECTRICAL METALLIC TUBING EXPANSION AND EXPANSION/DEFLECTION FITTINGS TO PREVENT DAMAGE TO ENCLOSED B. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND INDICATED TO BE REUSED, THEY MAY BE REUSED ONLY WHERE THEY ARE FREE FROM CONDUCTORS OR CONNECTED EQUIPMENT. THIS INCLUDES, BUT IS NOT LIMITED TO: 2. COPPER CONDUCTORS SIZE 6 AWG AND LARGER: USE MECHANICAL CONNECTORS OR (EMT). 9870 MAIN ROAD EXTENSION WORK. CORROSION, INTEGRITY AND CONTINUITY ARE VERIFIED, AND WHERE ACCEPTABLE TO THE 1. WHERE CONDUITS CROSS STRUCTURAL JOINTS INTENDED FOR EXPANSION, CONTRACTION, OR MATTIT IN A 11952 C. MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS THAT REMAIN ACTIVE. MODIFY COMPRESSION CONNECTORS. H. EXPOSED, INTERIOR, SUBJECT TO PHYSICAL DAMAGE: USE GALVANIZED STEEL RIGID METAL AUTHORITY HAVING JURISDICTION. DEFLECTION. C. TWIST-ON INSULATED SPRING CONNECTORS: RATED 600 V, 221 DEGREES F FOR STANDARD CONDUIT OR INTERMEDIATE METAL CONDUIT (IMC). INSTALLATION OR PROVIDE ACCESS PANEL AS APPROPRIATE. APPLICATIONS AND 302 DEGREES F FOR HIGH TEMPERATURE APPLICATIONS; PRE-FILLED WITH B. DO NOT USE PRODUCTS FOR APPLICATIONS OTHER THAN AS PERMITTED BY NFPA 70 AND 1. LOCATIONS SUBJECT TO PHYSICAL DAMAGE INCLUDE, BUT ARE NOT LIMITED TO: 2. WHERE CONDUITS ARE SUBJECT TO EARTH MOVEMENT BY SETTLEMENT OR FROST. PROJECT TYPE: 72 & 182 SEALANT AND LISTED AS COMPLYING WITH UL 486D FOR DAMP AND WET LOCATIONS. PRODUCT LISTING. a. WHERE EXPOSED BELOW 8 FEET, EXCEPT WITHIN ELECTRICAL AND COMMUNICATION ROOMS J. CONDENSATION PREVENTION: WHERE CONDUITS CROSS BARRIERS BETWEEN AREAS OF SECTION 26.05.19 C. UNLESS SPECIFICALLY INDICATED TO BE EXCLUDED, PROVIDE ALL REQUIRED COMPONENTS, POTENTIAL SUBSTANTIAL TEMPERATURE DIFFERENTIAL, PROVIDE SEALING FITTING OR LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES D. MECHANICAL CONNECTORS: PROVIDE BOLTED TYPE OR SET-SCREW TYPE. CONDUCTORS, CONNECTORS, CONDUIT, BOXES, FITTINGS, SUPPORTS, ACCESSORIES, ETC. AS OR CLOSETS. APPROVED SEALING COMPOUND AT AN ACCESSIBLE POINT NEAR THE PENETRATION TO E. COMPRESSION CONNECTORS: PROVIDE CIRCUMFERENTIAL TYPE OR HEX TYPE CRIMP b. WHERE EXPOSED BELOW 20 FEET IN WAREHOUSE AREAS. NECESSARY FOR A COMPLETE GROUNDING AND BONDING SYSTEM, PREVENT CONDENSATION. THIS INCLUDES, BUT IS NOT LIMITED TO: ^�► PART 1 PRODUCTS CONFIGURATION. D. WHERE CONDUCTOR SIZE IS NOT INDICATED, SIZE TO COMPLY WITH NFPA 70 BUT NOT LESS I. EXPOSED, EXTERIOR: USE GALVANIZED STEEL RIGID METAL CONDUIT, INTERMEDIATE METAL 1. WHERE CONDUITS PASS FROM OUTDOORS INTO CONDITIONED INTERIOR SPACES. CS PROJECT NUMBER-, 165265 1.07 WIRING ACCESSORIES CONDUIT IMC 1.01 CONDUCTOR AND CABLE APPLICATIONS THAN APPLICABLE MINIMUM SIZE REQUIREMENTS SPECIFIED. (IMC), OR PVC-COATED GALVANIZED STEEL RIGID METAL CONDUIT, 2. WHERE CONDUITS PASS FROM UNCONDITIONED INTERIOR SPACES INTO CONDITIONED INTERIOR A. ELECTRICAL TAPE: 1.02 GROUNDING AND BONDING COMPONENTS SPACES. A. DO NOT USE CONDUCTORS AND CABLES FOR APPLICATIONS OTHER THAN AS PERMITTED BY J. CONNECTIONS TO VIBRATING EQUIPMENT: 1. VINYL COLOR CODING ELECTRICAL TAPE: INTEGRALLY COLORED TO MATCH COLOR CODE 1. DRY LOCATIONS: USE FLEXIBLE METAL CONDUIT. NFPA 70 AND PRODUCT LISTING. A. GENERAL REQUIREMENTS: DAMP WET B. PROVIDE SINGLE CONDUCTOR BUILDING WIRE INSTALLED IN SUITABLE RACEWAY UNLESS INDICATED; LISTED AS COMPLYING WITH UL 510• MINIMUM THICKNESS OF 7 MIL; RESISTANT 1. PROVIDE PRODUCTS LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSE 2. ' OR CORROSIVE LOCATIONS: USE LIQUIDTIGHT FLEXIBLE METAL CONDUIT. SECTION 26.05.33.16 ARCHITECT OF RECORD" OTHERWISE INDICATED, PERMITTED, OR REQUIRED. TO ABRASION, CORROSION, AND SUNLIGHT; SUITABLE FOR CONTINUOUS TEMPERATURE INTENDED. 3. MAXIMUM LENGTH: 6 FEET UNLESS OTHERWISE INDICATED. BOXES FOR ELECTRICAL SYSTEMS C. METAL-CLAD CABLE IS PERMITTED ONLY AS FOLLOWS: ENVIRONMENT IN TO 221 DEGREES F. 2. PROVIDE PRODUCTS LISTED AND LABELED AS COMPLYING WITH UL 467 WHERE APPLICABLE. 4. VIBRATING EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO: 1. WHERE NOT OTHERWISE RESTRICTED, MAY BE USED: 2. VINYL INSULATING ELECTRICAL TAPE: COMPLYING WITH ASTM D3005 AND LISTED AS a. MOTORS. COMPLYING WITH UL 510; MINIMUM THICKNESS OF 7 MIL; RESISTANT TO ABRASION, B. CONDUCTORS FOR GROUNDING AND BONDING, IN ADDITION TO REQUIREMENTS OF SECTION 26 PART 1 PRODUCTS a. WHERE CONCEALED A13OVE ACCESSIBLE CEILINGS FOR FINAL CONNECTIONS FROM JUNCTION 0526: K. FISHED IN EXISTING WALLS, WHERE NECESSARY: USE FLEXIBLE METAL CONDUIT. 1.01 BOXES CORROSION, AND SUNLIGHT, CONFORMABLE FOR APPLICATION DOWN TO 0 DEGREES F AND 1.02 CONDUIT REQUIREMENTS BOXES TO LUMINAIRES. 1. USE INSULATED COPPER CONDUCTORS UNLESS OTHERWISE INDICATED. A. GENERAL REQUIREMENTS: `. SUITABLE FOR CONTINUOUS TEMPERATURE ENVIRONMENT UP TO 221 DEGREES F. A. EXISTING WORK: WHERE EXISTING CONDUITS ARE INDICATED TO BE REUSED THEY MAY BE EL�vAJ 1) MAXIMUM LENGTH: 6 FEET. B. WIRE PULLING LUBRICANT: LISTED; SUITABLE FOR USE WITH THE CONDUCTORS OR CABLES a. EXCEPTIONS: 1. DO NOT USE BOXES AND ASSOCIATED ACCESSORIES FOR APPLICATIONS OTHER THAN AS b. WHERE CONCEALED IN HOLLOW STUD WALLS, ABOVE ACCESSIBLE CEILINGS, AND UNDER TO BE INSTALLED AND SUITABLE FOR USE AT THE INSTALLATION TEMPERATURE. 1) USE BARE COPPER CONDUCTORS WHERE INSTALLED UNDERGROUND IN DIRECT CONTACT REUSED ONLY WHERE EY COMPLY WITH SPECIFIED REQUIREMENTS, ARE FREE FROM PERMITTED BY NFPA 70 AND PRODUCT LISTING. RAISED FLOORS FOR 13RANCH CIRCUITS UP TO 20 A. WITH EARTH. CORROSION, AND INTEGRITY IS VERIFIED BY PULLING A MANDREL THROUGH THEM. 2. PROVIDE ALL BOXES, FITTINGS, SUPPORTS, AND ACCESSORIES REQUIRED FOR A COMPLETE PART 2 EXECUTION B. PROVIDE ALL CONDUIT, FITTINGS, SUPPORTS, AND ACCESSORIES REQUIRED FOR A COMPLETE 1) EXCEP11ON: PROVIDE SINGLE CONDUCTOR BUILDING WIRE IN RACEWAY FOR CIRCUIT 2.01 PREPARATION 2) USE BARE COPPER CONDUCTORS WHERE DIRECTLY ENCASED IN CONCRETE NOT IN RACEWAY SYSTEM AND TO ACCOMMODATE DEVICES AND EQUIPMENT TO BE INSTALLED. SBLM ( RACEWAY SYSTEM. HOMERUN FROM FIRST OUTLET TO PANELBOARD. A. CLEAN RACEWAYS THOROUGHLY TO REMOVE FOREIGN MATERIALS BEFORE INSTALLING RACEWAY). C. PROVIDE PRODUCTS LISTED CLASSIFIED AND LABELED AS SUITABLE FOR THE PURPOSE 3, PROVIDE PRODUCTS LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSE 545 West 45th Street 4th Floor 1.02 CONDUCTOR AND CABLE GENERAL REQUIREMENTS CONDUCTORS AND CABLES. C. CONNECTORS FOR GROUNDING AND BONDING: INTENDED. INTENDED. New York, NY 10036 A. PROVIDE PRODUCTS THAT COMPLY WITH REQUIREMENTS OF NFPA 70. 2.02 INSTALLATION 1. DESCRIPTION: CONNECTORS APPROPRIATE FOR THE APPLICATION AND SUITABLE FOR THE 4. WHERE BOX SIZE IS NOT INDICATED, SIZE TO COMPLY WITH NFPA 70 BUT NOT LESS THAN B. PROVIDE PRODUCTS LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSE A. CIRCUITING REQUIREMENTS: CONDUCTORS AND ITEMS TO BE CONNECTED; LISTED AND LABELED AS COMPLYING WITH UL D. WHERE CONDUIT SIZE IS NOT INDICATED, SIZE TO COMPLY WITH NFPA 70 BUT NOT LESS APPLICABLE MINIMUM SIZE REQUIREMENTS SPECIFIED. T: 212.995.5600 THAN APPLICABLE MINIMUM SIZE REQUIREMENTS SPECIFIED. INTENDED. 1. UNLESS DIMENSIONED, CIRCUIT ROUTING INDICATED IS DIAGRAMMATIC. 467. 5. PROVIDE GROUNDING TERMINALS WITHIN BOXES WHERE EQUIPMENT GROUNDING CONDUCTORS www.sblm.com C. UNLESS SPECIFICALLY INDICATED TO BE EXCLUDED, PROVIDE ALL REQUIRED CONDUIT, BOXES, 2. COMMON NEUTRALS: UNLESS OTHERWISE INDICATED, SHARING OF NEUTRAL GROUNDED 2. UNLESS OTHERWISE INDICATED, USE EXOTHERMIC WELDED CONNECTIONS FOR UNDERGROUND, 1.03 GALVANIZED STEEL RIGID METAL CONDUIT (RMC) TERMINATE. WIRING, CONNECTORS, ETC. AS REQUIRED FOR A COMPLETE OPERATING SYSTEM. CONDUCTORS AMONG UP TO THREE SINGLE PHASE BRANCH CIRCUITS OF DIFFERENT PHASES CONCEALED AND OIIiER INACCESSIBLE CONNECTIONS. A. DESCRIPTION: NFPA 70, TYPE RMC GALVANIZED STEEL RIGID METAL CONDUIT COMPLYING B. OUTLET AND DEVICE BOXES UP TO 100 CUBIC INCHES, INCLUDING THOSE USED AS JUNCTION D. COMPLY WITH NEMA WC 70. INSTALLED IN THE SAME RACEWAY IS NOT PERMITTED. PROVIDE DEDICATED 3. UNLESS OTHERWISE INDICATED, USE MECHANICAL CONNECTORS, COMPRESSION CONNECTORS, B. FITTINGS:WITH ANSI C80.1 AND LISTED AND LABELED AS COMPLYING WITH UL 6. AND PULL BOXES: E. THERMOPLASTIC-INSULATED CONDUCTORS AND CABLES: LISTED AND LABELED AS COMPLYING OR EXOTHERMIC WELDED CONNECTIONS FOR ACCESSIBLE CONNECTIONS. 1. USE SHEET-STEEL BOXES FOR DRY LOCATIONS UNLESS OTHERWISE INDICATED OR REQUIRED. . WITH UL 83. NEUTRAL/GROUNDED CONDUCTOR FOR EACH INDIVIDUAL BRANCH CIRCUIT. PART 2 EXECUTION 1. NON-HAZARDOUS LOCATIONS: USE FITTINGS COMPLYING WITH NEMA FB 1 AND LISTED AND 2. USE CAST IRON BOXES OR CAST ALUMINUM BOXES FOR DAMP OR WET LOCATIONS UNLESS CONSULTANT ENGINEER• F. THERMOSET-INSULATED CONDUCTORS AND CABLES: LISTED AND LABELED AS COMPLYING B. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 2.01 INSTALLATION LABELED AS COMPLYING WITH UL 5148. OTHERWISE INDICATED OR REQUIRED; FURNISH WITH COMPATIBLE WEATHERPROOF GASKETED WITH UL 44. C. PERFORM WORK IN ACCORDANCE WITH NECA 1 (GENERAL WORKMANSHIP). 2. MATERIAL: USE STEEL OR MALLEABLE IRON. COVERS. G. CONDUCTORS FOR GROUNDING AND BONDING: ALSO COMPLY WITH SECTION 26 0526. D. INSTALL METAL-CLAD CABLE (TYPE MC) IN ACCORDANCE WITH NECA 120. A. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 3. CONNECTORS AND COUPLINGS: USE THREADED TYPE FITTINGS ONLY. THREADLESS SET 3. USE SUITABLE MASONRY TYPE BOXES WHERE FLUSH-MOUNTED IN MASONRY WALLS. PERFORM WORK IN ACCORDANCE WITH NECA B. 1 GENERAL WORKMANSHIP H. CONDUCTOR MATERIAL: E. INSTALLATION IN RACEWAY: B ( )• SCREW AND COMPRESSION (GLAND) TYPE FITTINGS ARE NOT PERMITTED. 4. SHEET-STEEL BOXES: COMPLY WITH NEMA OS 1, AND LIST AND LABEL AS COMPLYING WITH C. MAKE GROUNDING AND BONDING CONNECTIONS USING SPECIFIED CONNECTORS. 1. PROVIDE COPPER CONDUCTORS ONLY. ALUMINUM CONDUCTORS ARE NOT ACCEPTABLE FOR 1. TAPE ENDS OF CONDUCTORS AND CABLES TO PREVENT INFILTRATION OF MOISTURE AND 1.04 INTERMEDIATE METAL CONDUIT (IMC) UL 514A. CONSULTING THIS PROJECT. CONDUCTOR SIZES INDICATED ,ARE BASED ON COPPER. OTHER CONTAMINANTS. 1. REMOVE APPROPRIATE AMOUNT OF CONDUCTOR INSULATION FOR MAKING CONNECTIONS A. DESCRIPTION: NFPA 70, TYPE IMC GALVANIZED STEEL INTERMEDIATE METAL CONDUIT 5. CAST METAL BOXES: COMPLY WITH NEMA FB 1, AND LIST AND LABEL AS COMPLYING WITH ENGINEERS 2. COPPER CONDUCTORS: SOFT DRAWN ANNEALED, 98 PERCENT CONDUCTIVITY, UNCOATED 2. PULL ALL CONDUCTORS AND CABLES TOGETHER INTO RACEWAY AT SAME TIME. WITHOUT CUTTING, NICKING OR DAMAGING CONDUCTORS. DO NOT REMOVE CONDUCTOR COMPLYING WITH ANSI STRANDS TO FACILITATE INSERTION INTO CONNECTOR. C80.6 AND LISTED AND LABELED AS COMPLYING WITH UL 1242, UL 514A; FURNISH WITH THREADED HUBS. 240 WEST 37TH STREET,3RD FLOOR COPPER CONDUCTORS COMPLYING WITH ASTM B3, ASTM 88, OR ASTM 8787/6787M UNLESS 3. DO NOT DAMAGE CONDUCTORS AND CABLES OR EXCEED MANUFACTURER'S RECOMMENDED B. FITTINGS: 6. BOXES FOR SUPPORTING LUMINAIRES AND CEILING FANS: LISTED AS SUITABLE FOR THE NEW YORK,NY 10018 2. REMOVE NONCONDUCTIVE PAINT ENAMEL OR SIMILAR COATING AT THREADS CONTACT TEL 212.413.8400 OTHERWISE INDICATED. MAXIMUM PULLING TENSION AND SIDEWALL PRESSURE. 1. NON-HAZARDOUS LOCATIONS: USE FITTINGS COMPLYING WITH NEMA FB 1 AND LISTED AND TYPE AND WEIGHT OF LOAD TO BE SUPPORTED; FURNISHED WITH FIXTURE STUD TO 3. TINNED COPPER CONDUCTORS: COMPLY WITH ASTM 633. 4. USE SUITABLE WIRE PULLING LUBRICANT WHERE NECESSARY, EXCEPT WHEN LUBRICANT IS POINTS AND CONTACT SURFACES. www.hny-eng.com LABELED AS COMPLYING WITH UL 5146. ACCOMMODATE MOUNTING OF LUMINAIRE WHERE REQUIRED. 2250003925 3. EXOTHERMIC WELDS: MAKE CONNECTIONS USING MOLDS AND WELD MATERIAL SUITABLE FOR I. CONDUCTOR COLOR CODING: NOT RECOMMENDED BY THE MANUFACTURER. 2. MATERIAL: USE STEEL OR MALLEABLE IRON. 7. BOXES FOR GANGED DEVICES: USE MULTIGANG BOXES OF SINGLE-PIECE CONSTRUCTION. DO 1. COLOR CODE CONDUCTORS AS INDICATED UNLESS OTHERWISE REQUIRED BY THE AUTHORITY F. TERMINATE CABLES USING SUITABLE FITTINGS. THE ITEMS TO BE CONNECTED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 3. CONNECTORS AND COUPLINGS: USE THREADED TYPE FITTINGS ONLY. THREADLESS SET NOT USE FIELD-CONNECTED GANGABLE BOXES UNLESS SPECIFICALLY INDICATED OR HAVING JURISDICTION. MAINTAIN CONSISTENT COLOR CODING THROUGHOUT PROJECT. 1. METAL-CLAD CABLE (TYPE MC): 4. MECHANICAL CONNECTORS: SECURE CONNECTIONS ACCORDING TO MANUFACTURER'S SCREW AND COMPRESSION (GLAND) TYPE FITTINGS ARE NOT PERMITTED. PERMITTED. 2. COLOR CODING METHOD: INTEGRALLY COLORED INSULATION, a. USE LISTED FITTINGS. RECOMMENDED TORQUE SETTINGS. 1,05 PVC-COATED GALVANIZED STEEL RIGID METAL CONDUIT (RMC) C. CABINETS AND ENCLOSURES, INCLUDING JUNCTION AND PULL BOXES LARGER THAN 100 CUBIC 3. COLOR CODE: b. CUT CABLE ARMOR ONLY USING SPECIALIZED TOOLS TO PREVENT DAMAGING CONDUCTORS 5. COMPRESSION CONNECTORS: SECURE CONNECTIONS USING MANUFACTURER'S RECOMMENDED A. DESCRIPTION: NFPA 70, TYPE RMC GALVANIZED STEEL RIGID METAL CONDUIT WITH EXTERNAL INCHES: a. EQUIPMENT GROUND, ALL SYSTEMS: GREEN. OR INSULATION. DO NOT USE HACKSAW OR WIRE CUTTERS TO CUT ARMOR. POLYVINYL CHLORIDE (PVC) COATING COMPLYING WITH NEMA RN 1 AND LISTED AND LABELED 1. COMPLY WITH NEMA 250, AND LIST AND LABEL AS COMPLYING WITH UL 50 AND UL 50E, OR CONSULTANT' b. FOR MODIFICATIONS OR ADDITIONS TO EXISTING WIRING SYSTEMS, COMPLY WITH EXISTING G. INSTALL CONDUCTORS WITH A MINIMUM OF 12 INCHES OF SLACK AT EACH OUTLET. SECTION 26.05.29 AS COMPLYING WITH UL 6. UL 508A. COLOR CODE WHEN EXISTING CODE COMPLIES WITH NFPA 70 AND IS APPROVED BY THE H. NEATLY TRAIN AND BUNDLE CONDUCTORS INSIDE BOXES, WIREWAYS, PANELBOARDS AND HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 2. NEMA 250 ENVIRONMENT TYPE, UNLESS OTHERWISE INDICATED: AUTHORITY HAVING JURISDICTION. OTHER EQUIPMENT ENCLOSURES. B. EXTERIOR COATING: POLYVINYL CHLORIDE (PVC), NOMINAL THICKNESS OF 40 MIL.C. PVC-COATED FITTINGS: 3. JUNCTION AND PULL BOXES LARGER THAN 100 CUBIC INCHES: 1.03 SINGLE CONDUCTOR BUILDING WIRE I. GROUP OR OTHERWISE IDENTIFY NEUTRAL/GROUNDED CONDUCTORS WITH ASSOCIATED PART 1 PRODUCTS 1. MANUFACTURER: SAME AS MANUFACTURER OF PVC-COATED CONDUIT TO BE INSTALLED. a. PROVIDE SCREW-COVER OR HINGED-COVER ENCLOSURES UNLESS OTHERWISE INDICATED. A. DESCRIPTION: SINGLE CONDUCTOR INSULATED WIRE. UNGROUNDED CONDUCTORS INSIDE ENCLOSURES IN ACCORDANCE WITH NFPA 70. 1.01 SUPPORT AND ATTACHMENT COMPONENTS 2. NON-HAZARDOUS LOCATIONS: USE FITTINGS LISTED AND LABELED AS COMPLYING WITH UL PART 2 EXECUTION B. CONDUCTOR STRANDING: J. MAKE WIRING CONNECTIONS USING SPECIFIED WIRING CONNECTORS. A. GENERAL REQUIREMENTS: 2.01 INSTALLATION 1. PROVIDE ALL REQUIRED HANGERS, SUPPORTS, ANCHORS, FASTENERS, FITTINGS, ACCESSORIES, 5148. WITH MANUFACTURER'S INSTRUCTIONS. 1. FEEDERS AND BRANCH CIRCUITS: 1. MAKE SPLICES AND TAPS ONLY IN ACCESSIBLE BOXES. DO NOT PULL SPLICES INTO 3. MATERIAL: USE STEEL OR MALLEABLE IRON. A. INSTALL PRODUCTS IN ACCORDANCE a. SIZE 10 AWG AND SMALLER: SOLID. RACEWAYS OR MAKE SPLICES IN CONDUIT BODIES OR WIRING GUTTERS. AND HARDWARE AS NECESSARY FOR THE COMPLETE INSTALLATION OF ELECTRICAL WORK. 4. EXTERIOR COATING: POLYVINYL CHLORIDE PVC B. INSTALL BOXES IN ACCORDANCE WITH NECA 1 GENERAL WORKMANSHIP AND, WHERE 2. PROVIDE PRODUCTS LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSE (PVC), MINIMUM THICKNESS OF 40 MIL. ( ) b. SIZE 8 AWG AND LARGER: STRANDED. 2. REMOVE APPROPRIATE AMOUNT OF CONDUCTOR INSULATION FOR MAKING CONNECTIONS APPLICABLE, NECA 130, INCLUDING MOUNTING HEIGHTS SPECIFIED IN THOSE STANDARDS INTENDED WHERE APPLICABLE. D. PVC-COATED SUPPORTS: FURNISH WITH EXTERIOR COATING OF POLYVINYL CHLORIDE (PVC), 2. CONTROL CIRCUITS: STRANDED. WITHOUT CUTTING, NICKING OR DAMAGING CONDUCTORS. � WHERE MOUNTING HEIGHTS ARE NOT INDICATED. MINIMUM THICKNESS OF 15 MIL ATTACHMENT WHERE SUPPORT AND ATTACHCOMPONENT TYPES AND SIZES ARE NOT INDICATED, . C. INSULATION VOLTAGE RATING: 600 V. 3. DO NOT REMOVE CONDUCTOR STRANDS TO FACILITATE INSERTION INTO CONNECTOR. 3. C. ARRANGE EQUIPMENT TO PROVIDE MINIMUM CLEARANCES IN ACCORDANCE WITH 1.06 FLEXIBLE METAL CONDUIT (FMC) SELECT IN ACCORDANCE WITH MANUFACTURER'S APPLICATION CRITERIA AS REQUIRED FOR D. INSULATION: 4. CLEAN CONTACT SURFACES ON CONDUCTORS AND CONNECTORS TO SUITABLE REMOVE A. DESCRIPTION: NFPA 70, TYPE FMC STANDARD WALL STEEL FLEXIBLE METAL CONDUIT LISTED MANUFACTURER'S INSTRUCTIONS AND NFPA 70. 1. COPPER BUILDING WIRE: TYPE THHN/THWN OR THHN/THWN-2, EXCEPT AS INDICATED CORROSION, OXIDES, AND OTHER CONTAMINATES. DO NOT USE WIRE BRUSH ON PLATED THE LOAD TO BE SUPPORTED. INCLUDE CONSIDERATION FOR VIBRATION, EQUIPMENT D. BOX SUPPORTS: BELOW. CONNECTOR SURFACES. OPERATION, AND SHOCK LOADS WHERE APPLICABLE. AND LABELED AS COMPLYING WITH UL 1, AND LISTED FOR USE IN CLASSIFIED FIRESTOP 1. SECURE AND SUPPORT BOXES IN ACCORDANCE WITH NFPA 70 AND SECTION 26 0529 USING SYSTEMS TO BE USED. a. SIZE 4 AWG AND LARGER: TYPE XHHW-2. K. INSULATE SPLICES AND TAPS THAT ARE MADE WITH UNINSULATED CONNECTORS USING 4. DO NOT USE PRODUCTS FOR APPLICATIONS OTHER THAN AS PERMITTED BY NFPA 70 AND SUITABLE SUPPORTS AND METHODS APPROVED BY THE AUTHORITY HAVING JURISDICTION. 1.04 METAL-CLAD CABLE (,FOR NON-PATIENT CARE AREAS ONLY. DO NOT USE FOR LIFE METHODS SUITABLE FOR THE APPLICATION, WITH INSULATION AND MECHANICAL STRENGTH AT PRODUCT LISTING. 1.B. FITTINGS:DESCRIPTION: FITTINGS COMPLYING WITH NEMA FB 1 AND LISTED AND LABELED AS 2. PROVIDE INDEPENDENT SUPPORT FROM BUILDING STRUCTURE EXCEPT FOR CAST METAL BOXES SAFETY OR CRITICAL SYSTEMS.) LEAST EQUIVALENT TO UNSPLICED CONDUCTORS. B. CONDUIT AND CABLE SUPPORTS: STRAPS, CLAMPS, ETC. SUITABLE FOR THE CONDUIT OR COMPLYING WITH TI 5148. (OTHER THAN BOXES USED FOR FIXTURE SUPPORT) SUPPORTED BY THREADED CONDUIT SEAL' A. DESCRIPTION: NFPA 70, TYPE MC CABLE LISTED AND LABELED AS COMPLYING WITH UL L. INSULATE ENDS OF SPARE CONDUCTORS USING VINYL INSULATING ELECTRICAL TAPE. CABLE TO BE SUPPORTED. 2. MATERIAL: USE STEEL OR MALLEABLE IRON. CONNECTIONS IN ACCORDANCE WITH NFPA 70. DO NOT PROVIDE SUPPORT FROM PIPING, I 1`02 1569, AND LISTED FOR USE IN CLASSIFIED FIRESTOP SYSTEMS TO BE USED. M. INSTALL FIRESTOPPING TO PRESERVE FIRE RESISTANCE RATING OF PARTITIONS AND OTHER 1. CONDUIT STRAPS: ONE-HOLE OR TWO-HOLE TYPE; STEEL OR MALLEABLE IRON. DUCTWORK, OR OTHER SYSTEMS. pF III ELEMENTS, USING MATERIALS AND METHODS SPECIFIED IN SECTION 07.84.00. 2. CONDUIT CLAMPS: BOLTED TYPE UNLESS OTHERWISE INDICATED. 1.07 LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC) W. y B. CONDUCTOR STRANDING: E. INSTALL BOXES PLUMB AND LEVEL. W. O N. UNLESS SPECIFICALLY INDICATED TO BE EXCLUDED, PROVIDE FINAL CONNECTIONS TO ALL C. OUTLET BOX SUPPORTS: HANGERS, BRACKETS, ETC. SUITABLE FOR THE BOXES TO BE A. DESCRIPTION: NFPA 70, TYPE LFMC POLYVINYL CHLORIDE (PVC) JACKETED STEEL FLEXIBLE y�PP��o �FOQ 1. SIZE 10 AWG AND SMALLER: SOLID. F. FLUSH-MOUNTED BOXES: EQUIPMENT AND DEVICES, INCLUDING THOSE FURNISHED BY OTHERS, AS REQUIRED FOR A SUPPORTED. METAL CONDUIT LISTED AND LABELED AS COMPLYING WITH UL 360. * O * 2. SIZE 8 AWG AND LARGER: STRANDED. 1. INSTALL BOXES IN NONCOMBUSTIBLE MATERIALS SUCH AS CONCRETE, TILE, GYPSUM, PLASTER, C. INSULATION VOLTAGE RATING: 600 V. COMPLETE OPERATING SYSTEM. D. HANGER RODS: THREADED ZINC-PLATED STEEL UNLESS OTHERWISE INDICATED. B. FITTINGS: ETC. SO THAT FRONT EDGE OF BOX OR ASSOCIATED RAISED COVER IS NOT SET BACK FROM D. INSULATION: TYPE THHN, THHN/THWN, OR THHN/THWN-2. 2.03 CONDUCTORS AND CABLES 1. MINIMUM SIZE, UNLESS OTHERWISE INDICATED OR REQUIRED: 1. DESCRIPTION: FITTINGS COMPLYING WITH NEMA FB 1 AND LISTED AND LABELED AS FINISHED SURFACE MORE THAN 1/4 INCH OR DOES NOT PROJECT BEYOND FINISHED SURFACE. m to A. METAL CLAD CABLE TYPE MC AND/OR METAL CLAD HEALTH CARE FACILITY TYPE MC-HFC a. EQUIPMENT SUPPORTS: 1/2 INCH DIAMETER. COMPLYING WITH UL 5148. E. GROUNDING: FULL-SIZE INTEGRAL EQUIPMENT GROUNDING CONDUCTOR. / 2. INSTALL BOXES IN COMBUSTIBLE MATERIALS SUCH AS WOOD SO THAT FRONT EDGE 'OF BOX F. ARMOR: STEEL, CABLE: b. SINGLE CONDUIT UP TO 1 INCH (27 MM) TRADE SIZE: 1/4 INCH DIAMETER. 2. MATERIAL: USE STEEL OR MALLEABLE IRON. �0 c� INTERLOCKED TAPE. / OR ASSOCIATED RAISED COVER IS FLUSH WITH FINISHED SURFACE. F � 1. SECURING AND SUPPORTING: c. SINGLE CONDUIT LARGER THAN 1 INCH (27 MM) TRADE SIZE: 3/8 INCH DIAMETER. 1.08 ELECTRICAL METALLIC TUBING (EMT) �,0 081525 t� 1.05 METAL CLAD CABLE - HEALTH CARE FACILITY RATED TYPE MC-HCF (USE ALLOWED FOR A. DESCRIPTION: NFPA 70, TYPE EMT STEEL ELECTRICAL METALLIC TUBING COMPLYING WITH 3. REPAIR ROUGH OPENINGS AROUND BOXES IN NONCOMBUSTIBLE MATERIALS SUCH AS q�P�'SS1�N�`► NORMAL POWER CIRCUITS IN GENERAL PATIENT CARE AREAS. DO NOT USE FOR LIFE SAFETY OR a. SUPPORT PER ART 330 FOR MC CABLE d. OUTLET BOXES: 1/4 INCH DIAMETER. CONCRETE, TILE, GYPSUM, PLASTER, ETC. SO THAT THERE ARE NO GAPS OR OPEN SPACES b. SECURE CABLE WITHIN 12 INCHES OF EVERY BOX OR FITTING. ANSI C80.3 AND LISTED AND LABELED AS COMPLYING WITH UL 797. CRITICAL SYSTEMS.) e. LUMINAIRES: 1/4 INCH DIAMETER. BFITTINGS: GREATER THAN 1/8 INCH AT THE EDGE OF THE 80X. A. MC-HFC CABLE c. SECURE/SUB.SECURE/SUPPORTING INTERVALS SHALL NOT EXCEED SIX (6) FEET FOR MC CABLE. E. ANCHORS AND FASTENERS: G. INSTALL BOXES AS REQUIRED TO PRESERVE INSULATION INTEGRITY. 12/22/2022 1. DESCRIPTION: FITTINGS COMPLYING WITH NEMA FB 1 AND LISTED AND LABELED AS 1. MANUFACTURERS: d. UTILIZE STEEL CABLE HANGERS, ARLINGTON SMC SERIES OR EQUIVALENT, FOR MC CABLE 1. UNLESS OTHERWISE INDICATED AND WHERE NOT OTHERWISE RESTRICTED, USE THE ANCHOR H. INSTALL FIRESTOPPING TO PRESERVE FIRE RESISTANCE RATING OF PARTI110NS AND OTHER SUPPORT WHEREVER POSSIBLE SO AS TO PROVIDE FOR CABLE ROUTING IN A NEAT AND AND FASTENER TYPES INDICATED FOR THE SPECIFIED APPLICATIONS. COMPLYING WITH UL 5148. ELEMENTS, USING MATERIALS AND METHODS SPECIFIED IN SECTION 07.84.00. a. AFC CABLE SYSTEMS, INC (MC-STAT) 2. MATERIAL: USE STEEL OR MALLEABLE IRON. REVISIONS: WORKMANSHIP LIKE MANNER. 2. HOLLOW MASONRY: USE TOGGLE BOLTS. I. CLOSE UNUSED BOX OPENINGS. b. ENCORE WIRE CORPORATION (MC-MCMP) 2. TYPE MC AND OR MC-HCF CABLE MAY ONLY BE USED: 3. HOLLOW STUD WALLS: USE TOGGLE BOLTS. 3. CONNECTORS AND COUPLINGS: USE COMPRESSION (GLAND) OR SET-SCREW TYPE. / J. INSTALL BLANK WALL PLATES ON JUNCTION BOXES AND ON OUTLET BOXES WITH NO DEVICES c. SOUTHWIRE COMPANY/(HCF-MCAP) a. DO NOT USE INDENTER TYPE CONNECTORS AND COUPLINGS. 09-26-2022 OL RX REVIEW#1 a. IN LIEU OF FLEXIBLE CONDUIT AND WIRING FROM LIGHT FIXTURES IN ACCESSIBLE CEILINGS 4. STEEL: USE BEAM CLAMPS, MACHINE BOLTS, OR WELDED THREADED STUDS. OR EQUIPMENT INSTALLED OR DESIGNATED FOR FUTURE USE. 2. UL S UNJACKETED AND/OR UL STANDARD ION FOR METAL-CLAD CLAD CABLES, TO JUNCTION BOXES (ATTACHED TO BUILDING STRUCTURE) ABOVE THE CEILING. PROVIDE 5. SHEET METAL: USE SHEET METAL SCREWS. 4. DAMP OR WET LOCATIONS (WHERE PERMITTED): USE FITTINGS LISTED FOR USE IN WET K. PROVIDE GROUNDING AND BONDING IN ACCORDANCE WITH SECTION 26.05.26. UL STANDARD 83, UL STANDARD 1063, FEDERAL SPECIFICATION A-A59544, IEEE 1202 LOCATIONS. 09-27-2022 OL RX REVIEW#2 CABLE WHIPS OF SUFFICIENT LENGTHS TO ALLOW FOR RELOCATING EACH LIGHT FIXTURE PART 2 EXECUTION VERTICAL CABLE TRAY FLAME TEST AND THE NEC. MC CABLE SHALL BE LISTED FOR USE IN WITHIN A 5-FOOT RADIUS OF ITS INSTALLED LOCATION BUT NOT EXCEEDING 6 FEET IN 2.01 INSTALLATION 1.09 ACCESSORIES 09-27-2022 OL RX REVIEW#3 3. ARMOR ASSEMBLY: ALUMINUM INTERLOCKED ARMOR AND FULL-SIZED SOLID BARE ALUMINUM UL 1 2 AND 3 HOUR THROUGH-PENETRATION FIRESTOP SYSTEMS. A. CONDUIT JOINT COMPOUND: CORROSION-RESISTANT ELECTRICALLY CONDUCTIVE; SUITABLE ' UNSUPPORTED LENGTHS. A. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 10-03-2022 PL POST FOR USE WITH THE CONDUIT TO BE INSTALLED. b. FOR VERTICAL DROPS AND HORIZONTAL WIRING IN STUD WALLS. B. PERFORM WORK IN ACCORDANCE WITH NECA 1 (GENERAL WORKMANSHIP). GROUNDING/BONDING CONDUCTOR IN INTIMATE AND CONTINUOUS CONTACT WITH ARMOR - c. IN LIEU OF METAL RACEWAY, ONLY FOR 15A AND 20A BRANCH CIRCUITS WITH UP TO C. PROVIDE INDEPENDENT SUPPORT FROM BUILDING STRUCTURE. DO NOT PROVIDE SUPPORT B. PULL STRINGS: USE NYLON CORD WITH AVERAGE BREAKING STRENGTH OF NOT LESS THAN RECOGNIZED AS EQUIPMENT GROUND PER NEC ARTICLES 250.118 AND 517.13(A). FOUR (4) CONDUCTORS NOT INCLUDING GROUNDING AND/OR BONDING CONDUCTORS) FROM PIPING DUCTWORK OR OTHER SYSTEMS. 200 POUND-FORCE. 12-23-2022 BID/PERMIT SET 4. PHASE CONDUCTORS: SCLiD SOFT-DRAWN COPPER, THHN-INSULATED SINGLE CONDUCTORS, CFOR SEALING FITTINGS: LISTED FOR USE WITH THE PARTICULAR FITTINGS AND ONLY IN DRY CONCEALED LOCATIONS ABOVE GRADE, EXCEPT WHERE SPECIFICALLY D. UNLESS SPECIFICALLY INDICATED OR APPROVED BY ARCHITECT, DO NOT PROVIDE SUPPORT C. SEALING COMPOUND COLOR CODE: ICEA METHOD 1. TO BE INSTALLED. NOT PERMITTED BY THE NEC. FROM SUSPENDED CEILING SUPPORT SYSTEM OR CEILING GRID. 5. GROUNDING CONDUCTOR: SOLID, SOFT-DRAWN COPPER, THHN GREEN INSULATED GROUNDING 3. MC CABLE SHALL NOT BE USED FOR ANY USE NOT LISTED IN THE PARAGRAPH ABOVE. E. UNLESS SPECIFICALLY INDICATED OR APPROVED BY ARCHITECT, DO NOT PROVIDE SUPPORT PART 2 EXECUTION CONDUCTOR SIZED PER NEC 517.13(B) AND TABLE 250.122. EXAMPLES OF THOSE USES INCLUDE, BUT ARE NOT LIMITED TO: FROM ROOF DECK. 2.01 INSTALLATION 6. TYPE MC-HCF CABLE SHALL BE 'HOSPITAL CARE FACILITY"TYPE IN ACCORDANCE WITH NEC a. IN LOCATIONS NOT PERMITTED BY THE NEC. F. DO NOT PENETRATE OR OTHERWISE NOTCH OR CUT STRUCTURAL MEMBERS WITHOUT A. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. SECTION 517.13 WITH RACEWAY SYSTEM LISTED AS AN EQUIPMENT GROUND RETURN PATH. b. WHEN SPECIFICALLY NOT ALLOWED BY THE LOCAL AHJ AND/OR OWNER/LANDLORD. APPROVAL OF STRUCTURAL ENGINEER. B. PERFORM WORK IN ACCORDANCE WITH NECA 1 (GENERAL WORKMANSHIP). 7. MARKING: CABLE MARKINGS SHALL COMPLY WITH THE REQUIREMENTS OF NEC ART 310 .11(1). c. HOMERUNS TO PANELBOARDS. NOTE: WHERE METAL CLAD CABLE IS UTILIZED FOR G. EQUIPMENT SUPPORT AND ATTACHMENT: C. INSTALL GALVANIZED STEEL RIGID METAL CONDUIT (RMC) IN ACCORDANCE WITH NECA 101. OUTER ARMOR SHALL HAVE GREEN-COLOR FCR EASY IDENTIFICATION AS HOSPITAL PATIENT RECEPTACLE, LIGHTING, AND/OR MISCELLANEOUS LOAD BRANCH CIRCUITING, THE 1. USE METAL FABRICATED SUPPORTS OR SUPPORTS ASSEMBLED FROM METAL CHANNEL D. INSTALL INTERMEDIATE METAL CONDUIT (IMC) IN ACCORDANCE WITH NECA 101. CARE RATED. ORIGINATING POINT OF THE HOMERUN SHALL BE AT THE FIRST (MOST UPSTREAM) LOAD IN (STRUT) TO SUPPORT EQUIPMENT AS REQUIRED. E. INSTALL PVC-COATED GALVANIZED STEEL RIGID METAL CONDUIT (RMC) USING ONLY TOOLS B. MC - HCF CABLE (WITH 0-10V DIMMING CON-ROL WIRING):: THE CIRCUIT OR AT A JUNCTION BOX LOCATED IN THE ACCESSIBLE CEILING SPACE 2. USE METAL CHANNEL (STRUT) SECURED TO STUDS TO SUPPORT EQUIPMENT APPROVED BY THE MANUFACTURER. DRAWING BY: SGC 1. MANUFACTURERS: IMMEDIATELY ABOVE THE FIRST (MOST UPSTREAM) LOAD. REFERENCE DEFINITIONS IN THIS SURFACE-MOUNTED ON HOLLOW STUD WALLS WHEN WALL STRENGTH IS NOT SUFFICIENT TO F. CONDUIT SUPPORT: a. AFC CABLE SYSTEMS, INC (MC- HCF-PCS) SECTION FOR DEFINITION ON 'HOMERUN" RESIST PULL-OUT. 1. SECURE AND SUPPORT CONDUITS IN ACCORDANCE WITH NFPA 70 AND SECTION 26.05.29 CHECKED BY: EG b. ENCORE WIRE CORPORATION (MC- HCF-PCS) d. WHERE EXPOSED TO VIEW. 3. USE METAL CHANNEL (STRUT) TO SUPPORT SURFACE-MOUNTED EQUIPMENT IN WET OR DAMP USING SUITABLE SUPPORTS AND METHODS APPROVED BY THE AUTHORITY HAVING c. SOUTHWIRE COMPANY (MC-HCF-PCS DUO) e. WHERE SUBJECT TO PHYSICAL DAMAGE. LOCATIONS TO PROVIDE SPACE BETWEEN EQUIPMENT AND MOUNTING SURFACE. JURISDICTION. DATE: 09-22-2022 2. 60OV, UNJACKETED AND/OR PVC-JACKETED UL STANDARD 1569 FOR METAL-CLAD CABLES, f. CORROSIVE OR HAZARDOUS LOCATIONS. 4. SECURELY FASTEN FLOOR-MOUNTED EQUIPMENT. DO NOT INSTALL EQUIPMENT SUCH THAT IT 2• PROVIDE INDEPENDENT SUPPORT FROM BUILDING STRUCTURE. DO NOT PROVIDE SUPPORT UL STANDARD 83, UL STANDARD 1063, FEDERAL SPECIFICATION A-A59544, IEEE 1202 g. WET LOCATIONS. RELIES ON ITS OWN WEIGHT FOR SUPPORT. FROM PIPING, DUCTWORK, OR OTHER SYSTEMS. VERTICAL CABLE TRAY FLAME TEST AND THE NEC. MC CABLE SHALL BE LISTED FOR USE IN h. EMERGENCY CIRCUITS COVERED BY NFPA ART 700 EMERGENCY SYSTEMS H. SECURE FASTENERS ACCORDING TO MANUFACTURER'S RECOMMENDED TORQUE SETTINGS. G. CONNECTIONS AND TERMINATIONS: JOB NUMBER: 022139 UL 1, 2, AND 3 HOUR THROUGH-PENETRATION FIRESTOP SYSTEMS. I. REMOVE TEMPORARY SUPPORTS. 1. USE APPROVED ZINC-RICH PAINT OR CONDUIT JOINT COMPOUND ON FIELD-CUT THREADS OF 3. ARMOR ASSEMBLY: ALUMINUM INTERLOCKED ARMOR AND FULL-SIZED SOLID BARE ALUMINUM GALVANIZED STEEL CONDUITS PRIOR TO MAKING CONNECTIONS. TITLE: GROUNDING/BONDING CONDUCTOR IN INTIMATE AND CONTINUOUS CONTACT WITH ARMOR - SECTION 26.05.33.13 2. WHERE TWO THREADED CONDUITS MUST BE JOINED AND NEITHER CAN BE ROTATED, USE THREE-PIECE COUPLINGS OR SPLIT COUPLINGS. DO NOT USE RUNNING THREADS. ELECTRICAL CONDUIT FOR ELECTRICAL SYSTEMS RECOGNIZED AS EQUIPMENT GROUND PER NEC ARTICLES 250.118 AND 517.13(A). 3. USE SUITABLE ADAPTERS WHERE REQUIRED TO TRANSITION FROM ONE TYPE OF CONDUIT TO 4. PHASE CONDUCTORS: SOLID SOFT-DRAWN COPPER, THHN-INSULATED SINGLE CONDUCTORS, ANOTHER. SPECIFICATIONS COLOR CODE: ICEA METHOD 1. 4. PROVIDE DRIP LOOPS FOR LIQUIDTIGHT FLEXIBLE CONDUIT CONNECTIONS TO PREVENT 5. CONTROL CONDUCTORS: COLOR CODED CLASS2/CLASS3 TWISTED JACKETED PAIRS. DRAINAGE OF LIQUID INTO CONNECTORS. SHEET NUMBER: 6. GROUNDING CONDUCTOR: SOLID, SOFT-DRAWN COPPER, THHN GREEN INSULATED GROUNDING 5. TERMINATE THREADED CONDUITS IN BOXES AND ENCLOSURES USING THREADED HUBS OR CONDUCTOR SIZED PER NEC 517.13(B) AND TABLE 250.122. DOUBLE LOCK NUTS FOR DRY LOCATIONS AND RAINTIGHT HUBS FOR WET LOCATIONS. 7. TYPE MC-HCF CABLE SHALL BE 'HOSPITAL CARE FACILITY"TYPE IN ACCORDANCE WITH NEC 6. PROVIDE INSULATING BUSHINGS OR INSULATED THROATS AT ALL CONDUIT TERMINATIONS TO SECTION 517.13 WITH RACEWAY SYSTEM LISTED AS AN EQUIPMENT GROUND RETURN PATH. PROTECT CONDUCTORS. El 8. MARKING: CABLE MARKINGS SHALL COMPLY WITH THE REQUIREMENTS OF NEC ART 310 .11(1). 7. SECURE JOINTS AND CONNECTIONS TO PROVIDE MAXIMUM MECHANICAL STRENGTH AND NEWYORK ALTERATION WARNING STATEMENT: o OUTER ARMOR SHALL HAVE GREEN-COLOR FOR EASY IDENTIFICATION AS HOSPITAL PATIENT ELECTRICAL CONTINUITY. IT IS A VIOLATION OF THE NEW YORK EDUCATION LAW,ARTICLE 145,SECTION COMMENTS: o CARE RATED. H. PENETRATIONS: 7209 FOR ANY PERSON, UNLESS THE INDIVIDUAL IS ACTING UNDER THE I 1. DO NOT PENETRATE OR OTHERWISE NOTCH OR CUT STRUCTURAL MEMBERS, INCLUDING DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AIN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE 0 NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF o SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. SECTION 26.05.53 PART 2 EXECUTION K. INSTALL WALL PLATES TO FIT COMPLETELY FLUSH TO WALL WITH NO GAPS AND ROUGH SPECIFIED IN NEMA 410. IDENTIFICATION FOR ELECTRICAL SYSTEMS 2.01 INSTALLATION OPENING COMPLETELY COVERED WITHOUT STRAIN ON WALL PLATE. REPAIR OR REINSTALL B. DIMMABLE LED DRIVERS: A. PERFORM WORK IN ACCORDANCE WITH NECA 1 (GENERAL WORKMANSHIP). IMPROPERLY INSTALLED OUTLET BOXES OR IMPROPERLY SIZED ROUGH OPENINGS. DO NOT 1. DIMMING RANGE: CONTINUOUS DIMMING FROM 100 PERCENT TO FIVE PERCENT RELATIVE PART 2 PRODUCTS B. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. USE OVERSIZED WALL PLATES IN LIEU OF MEETING THIS REQUIREUIENT. LIGHT OUTPUT UNLESS DIMMING CAPABILITY TO LOWER LEVEL IS INDICATED WITHOUT 1.01 IDENTIFICATION REQUIREMENTS C. INSTALL PANELBOARDS IN ACCORDANCE WITH NECA 407 AND NEMA PB 1.1. L. INSTALL BLANK WALL PLATES ON JUNCTION BOXES AND ON OUTLET BOXES WITH NO WIRING FLICKER. A. IDENTIFICATION FOR EQUIPMENT: D. ARRANGE EQUIPMENT TO PROVIDE MINIMUM CLEARANCES IN ACCORDANCE WITH DEVICES INSTALLED OR DESIGNATED FOR FUTURE USE. 1. USE IDENTIFICATION NAMEPLATE TO IDENTIFY EACH PIECE OF ELECTRICAL DISTRIBUTION AND MANUFACTURER'S INSTRUCTIONS AND NFPA 70. 2. CONTROL COMPATIBILITY: FULLY COMPATIBLE WITH THE DIMMING CONTROLS TO BE CONTROL EQUIPMENT AND ASSOCIATED SECTIONS, COMPARTMENTS, AND COMPONENTS. E. INSTALL PANELBOARDS PLUMB. INSTALLED. a. PANELBOARDS: F. INSTALL FLUSH-MOUNTED PANELBOARDS SO THAT TRIMS FIT COMPLETELY FLUSH TO WALL SECTION 26.28.16 1.05 ACCESSORIES TM 1) IDENTIFY POWER SOURCE AND CIRCUIT NUMBER. INCLUDE LOCATION WHEN NOT WITHIN WITH NO GAPS AND ROUGH OPENING COMPLETELY COVERED. ENCLOSED SWITCHES A. STEMS FOR SUSPENDED LUMINAIRES: STEEL TUBING, MINIMUM 1/2" SIZE, FACTORY lmuharmacy SIGHT OF EQUIPMENT. G. MOUNT PANELBOARDS SUCH THAT THE HIGHEST POSITION OF ANY OPERATING HANDLE FOR FINISHED TO MATCH LUMINAIRE OR FIELD-PAINTED AS DIRECTED. 2) USE TYPEWRITTEN`CIRCUIT DIRECTORY TO IDENTIFY LOAD(S) SERVED FOR PANELBOARDS CIRCUIT BREAKERS OR SWITCHES DOES NOT EXCEED 79 INCHES ABOVE THE FLOOR OR PART 1 PRODUCTS PART 2 EXECUTION WITH A DOOR. IDENTIFY SPARES AND SPACES USING PENCIL. WORKING PLATFORM. b. ENCLOSED SWITCHES, CIRCUIT BREAKERS, AND MOTOR CONTROLLERS: H. INSTALL ALL FIELD-INSTALLED BRANCH DEVICES, COMPONENTS, AND ACCESSORIES. 1.01 ENCLOSED SAFETY SWITCHES 2.01 INSTALLATION Reset + Rx Di ital Screen 1) IDENTIFY POWER SOURCE AND CIRCUIT NUMBER. INCLUDE LOCATION WHEN NOT WITHIN I. PROVIDE FILLER PLATES TO COVER UNUSED SPACES IN PANELBOARDS. A. DESCRIPTION: QUICK-MAKE, QUICK-BREAK ENCLOSED SAFETY SWITCHES LISTED AND A. COORDINATE LOCATIONS OF OUTLET BOXES PROVIDED UNDER SEC11ON 26.05.33.16 AS Expansion + P oto SIGHT OF EQUIPMENT. NATIONAL ACCOUNT LABELED AS COMPLYING WITH UL 98; GENERAL DUTY; RATINGS, CONFIGURATIONS, AND REQUIRED FOR INSTALLATION OF LUMINAIRES PROVIDED UNDER THIS SECTION. B. IDENTIFICATION FOR CONDUCTORS AND CABLES: A. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE MANUFACTURERS FEATURES AS INDICATED ON THE DRAWINGS. B. PERFORM WORK IN ACCORDANCE WITH NECA 1 (GENERAL WORKMANSHIP). 1. COLOR CODING FOR POWER CONDUCTORS 600 V AND LESS: COMPLY WITH SECTION LISTED BELOW FOR FURNISHING THE ELECTRICAL SWITCHGEAR SPECIFIED IN THIS SECTION. B. PROVIDE PRODUCTS LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSESTORE NUMBER 3105 26.05.19. COMPLETE INSTALLA11ON SHALL BE BY THE CONTRACTOR. THE GENERAL CONTRACTOR IS INTENDED. C. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 2. USE IDENTIFICATION NAMEPLATE OR IDENTIFICATION LABEL TO IDENTIFY COLOR CODE FOR RESPONSIBLE FOR CONTACTING THE MANUFACTURER FOR PRICING QUOTATIONS, PLACING ORDERS, C. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS SUITABLE FOR CONTINUOUS OPERATION: D. INSTALL LUMINAIRES SECURELY, IN A NEAT AND WORKMANLIKE MANNER, AS SPECIFIED IN D 9870 MAIN ROA UNGROUNDED AND GROUNDED POWER CONDUCTORS INSIDE DOOR OR ENCLOSURE AT EACH AND FURTHER INFORMATION, CALL THE APPROPRIATE MANUFACTURER FOR THE AREA THE STORE IS UNDER THE FOLLOWING SERVICE CONDITIONSNECA 500 (COMMERCIAL LIGHTING) AND NECA 502 (INDUSTRIAL LIGHTING). MATTIT IN A 11952 PIECE OF FEEDER OR BRANCH-CIRCUIT DISTRIBUTION EQUIPMENT WHEN PREMISES HAS LOCATED IN. E. INSTALL LUMINAIRES PLUMB AND SQUARE AND ALIGNED WITH BUILDING LINES AND WITH FEEDERS OR BRANCH CIRCUITS SERVED BY MORE THAN ONE NOMINAL VOLTAGE SYSTEM. 1. WIEDENBACH - BROWN CO. INC. AT (781) 769-9868, CVS®WBLIGHT.COM OR 1. ALTITUDE: LESS THAN 6,600 FEET. ADJACENT LUMINAIRES. PROJECT TYPE: /72 & 182 1.02 IDENTIFICATION NAMEPLATES AND LABELS CVSSUPPORT®WBLIGHT.COM 2. AMBIENT TEMPERATURE: BETWEEN -22 DEGREES F AND 104 DECREES F. A. IDENTIFICATION NAMEPLATES: a. AREAS: AL, AR, AZ, CA, CO, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MD, MI, MN, MO, MS, D. HORSEPOWER RATING: SUITABLE FOR CONNECTED LOAD. F. INSTALL ACCESSORIES FURNISHED WITH EACH LUMINAIRE. 1. MATERIALS: MT, INC, ND, NE, NM, NV, OH, OK, OR, PR, SC, SD, TN, TX, UT, VA, WA, WI, WV, WY. G. BOND PRODUCTS AND METAL ACCESSORIES TO BRANCH CIRCUIT EQUIPMENT GROUNDING a. INDOOR CLEAN, DRY LOCATIONS: USE PLASTIC NAMEPLATES. E. VOLTAGE RATING: SUITABLE FOR CIRCUIT VOLTAGE. b. OUTDOOR LOCATIONS: USE PLASTIC, STAINLESS STEEL, OR ALUMINUM NAMEPLATES 2. NESCO, INC. AT (781) 828-9494. CONDUCTOR. CS PROJECT NUMBER: 165265 F. SHORT CIRCUIT CURRENT RATING: H. EMERGENCY LIGHTING UNITS: SUITABLE FOR EXTERIOR USE. a, AREAS: CT, MA, ME, NH, NJ, NY, PA, RI, VT. 1. PROVIDE ENCLOSED SAFETY SWITCHES WHEN PROTECTED BY THE FUSES OR SUPPLY SIDE 2. PLASTIC NAMEPLATES: TWO-LAYER OR THREE-LAYER LAMINATED ACRYLIC OR 1. UNLESS OTHERWISE INDICATED, CONNECT UNIT TO UNSWITCHED POWER FROM SAME CIRCUIT OVERCURRENT NOT L PROTECTIVE DEVICES BL BE INSTALLED WITH LISTED SHORT CIRCUIT CURRENT ARCHITECT OF RECORD ELECTRICALLY NON-CONDUCTIVE PHENOLIC WITH BEVELED EDGES; MINIMUM THICKNESS OF SECTION 26.27.26 RATING NOT LESS THAN THE AVAILABLE FAULT CURRENT AT THE INSTALLED LOCATION AS FEEDING NORMAL LIGHTING IN SAME ROOM OR AREA. BYPASS LOCAL SWITCHES 1/16 INCH; ENGRAVED TEXT. INDICATED ON THE DRAWINGS. CONTACTORS, OR OTHER LIGHTING CONTROLS. 3. STAINLESS STEEL NAMEPLATES: MINIMUM THICKNESS OF 1/32 INCH; ENGRAVED OR WIRING DEVICES I. EXIT SIGNS: LASER-ETCHED TEXT. G. PROVIDE WITH SWITCH BLADE CONTACT POSITION THAT IS VISIBLE WHEN THE COVER IS 1. UNLESS OTHERWISE INDICATED, CONNECT UNIT TO UNSWITCHED POWER FROM SAME CIRCUIT 4. MOUNTING HOLES FOR MECHANICAL FASTENERS: TWO, CENTERED ON SIDES FOR SIZES UP OPEN. , PART 1 PRODUCTS FEEDING NORMAL LIGHTING IN SAME ROOM OR AREA. BYPASS LOCAL SWITCHES, TO 1 INCH HIGH; FOUR, LOCATED AT CORNERS FOR LARGER SIZES. H. CONDUCTOR TERMINATIONS: SUITABLE FOR USE WITH THE CONDJCTORS TO BE INSTALLED. CONTACTORS, OR OTHER LIGHTING CONTROLS. B. IDENTIFICATION LABELS: 1.01 WIRING DEVICE APPLICATIONS I. PROVIDE SOLIDLY BONDED EQUIPMENT GROUND BUS IN EACH ENCLOSED SAFETY SWITCH, 1. MATERIALS: USE SELF-ADHESIVE LAMINATED PLASTIC LABELS; UV, CHEMICAL, WATER, A. PROVIDE WIRING DEVICES SUITABLE FOR INTENDED USE AND WITH RATINGS ADEQUATE FOR WITH A SUITABLE LUG FOR TERMINATING EACH t J. INSTALL LAMPS IN EACH LUMINAIRE. HEAT, AND ABRASION RESISTANT. LOAD SERVED. EQUIPMENT ME T GROUJDING CONDUCTOR. J 2. TEXT: USE FACTORY PRE-PRINTED OR MACHINE-PRINTED TEXT. DO NOT USE HANDWRITTEN B. FOR SINGLE RECEPTACLES INSTALLED ON AN INDIVIDUAL BRANCH CIRCUIT, PROVIDE J. ENCLOSURES: COMPLY WITH NEMA 250, AND LIST AND LABEL AS COMPLYING WITH UL 50 TEXT UNLESS OTHERWISE INDICATED. RECEPTACLE WITH AMPERE RATING NOT LESS THAN THAT OF THE BRANCH CIRCUIT. AND UL 50E. SBLM 1.03 WARNING SIGNS AND LABELS 1. ENVIRONMENT TYPE PER NEMA 250: UNLESS OTHERWISE INDICATED, AS SPECIFIED FOR THE 545 West 45th Street 4th Floor A. COMPLY WITH ANSI 2535.2 OR ANSI 2535.4 AS APPLICABLE. C. PROVIDE WEATHER RESISTANT GFCI RECEPTACLES WITH SPECIFIED WEATHERPROOF COVERS FOLLOWING INSTALLATION LOCATIONS: B. WARNING SIGNS: FOR RECEPTACLES INSTALLED OUTDOORS OR IN DAMP OR WET LOCATIONS. K. PROVIDE SAFETY INTERLOCK TO PREVENT OPENING THE COVER WITH THE SWITCH IN THE ON New York, NY 10036 1. MATERIALS: D. PROVIDE GFCI PROTECTION FOR RECEPTACLES INSTALLED WITHIN 6 FEET OF SINKS. POSITION WITH CAPABILITY OF OVERRIDING INTERLOCK FOR TESTING PURPOSES. T: 212.995.5600 a. INDOOR DRY, CLEAN LOCATIONS: USE FACTORY PRE-PRINTED RIGID PLASTIC OR E. PROVIDE GFCI PROTECTION FOR RECEPTACLES SERVING ELECTRIC DRINKING FOUNTAINS. L. GENERAL DUTY SWITCHES: www.sblm.com SELF-ADHESIVE VINYL SIGNS. F. UNLESS NOTED OTHERWISE, DO NOT USE COMBINATION SWITCH RECEPTACLE DEVICES. b. OUTDOOR LOCATIONS: USE FACTORY PRE-PRINTED RIGID ALUMINUM SIGNS. / 1. CONDUCTOR TERMINATIONS: 2. RIGID SIGNS: PROVIDE FOUR MOUNTING HOLES AT CORNERS FOR MECHANICAL FASTENERS. 1.02 WIRING DEVICE FINISHES a. PROVIDE MECHANICAL LUGS. 3. MINIMUM SIZE: 7 BY 10 INCHES UNLESS OTHERWISE INDICATED. A. PROVIDE WIRING DEVICE FINISHES AS DESCRIBED BELOW UNLESS OTHERWISE INDICATED. b. LUG MATERIAL: ALUMINUM, SUITABLE FOR TERMINATING ALUMINUM OR COPPER CONSULTANT ENGINEER' C. WARNING LABELS: B. WIRING DEVICES, UNLESS OTHERWISE INDICATED: WHITE WITH WHITE NYLON WALL PLATE. CONDUCTORS. 1. MATERIALS: USE FACTORY PRE-PRINTED OR MACHINE-PRINTED SELF-ADHESIVE POLYESTER OR SELF-ADHESIVE VINYL LABELS; UV, CHEMICAL, WATER, HEAT, AND ABRASION RESISTANT; C. WIRING DEVICES INSTALLED IN UNFINISHED SPACES: GRAY WITH GALVANIZED STEEL WALL 2. PROVIDE EXTERNALLY OPERABLE HANDLE WITH MEANS FOR LOCKING IN THE OFF POSITION, PRODUCED USING MATERIALS RECOGNIZED TO UL 969. PLATE. CAPABLE OF ACCEPTING TWO PADLOCKS. 2. MACHINE-PRINTED LA13ELS: USE THERMAL TRANSFER PROCESS PRINTING MACHINES AND D. WIRING DEVICES INSTALLED IN WET OR DAMP LOCATIONS: WHITE WITH SPECIFIED PART 2 EXECUTION ACCESSORIES RECOMMENDED BY LABEL MANUFACTURER. WEATHERPROOF COVER. 2.01 INSTALLATION CONSULTING 3. MINIMUM SIZE: 2 BY 4 INCHES UNLESS OTHERWISE INDICATED. ENGINEERS PART 2 EXECUTION 1.03 WALL SWITCHES A. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 240 WEST 37TH STREET,3RD FLOOR A. WALL SWITCHES - GENERAL REQUIREMENTS: AC ONLY, QUIET OPERATING, GENERAL-USE PERFORM WORK IN ACCORDANCE WITH NECA 1 GENERAL WORKMANSHIP). NEWYORK,NY 10018 2.01 INSTALLATION B.SNAP SWITCHES WITH SILVER ALLOY CONTACTS, COMPLYING WITH NEMA WD 1 AND NEMA WD ( ) TEL 212.413.8400 A. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. C. ARRANGE EQUIPMENT TO PROVIDE MINIMUM CLEARANCES IN ACCORDANCE WITH www.hny-ong.com B. INSTALL IDENTIFICATION PRODUCTS TO BE PLAINLY VISIBLE FOR EXAMINATION, ADJUSTMENT, 6, AND LISTED AS COMPLYING WITH UL 20 AND WHERE APPLICABLE, FS W-S-896; TYPES SERVICING, AND MAINTENANCE. AS INDICATED ON THE DRAWINGS. MANUFACTURER'S INSTRUCTIONS AND NFPA 70. 2250003925 C. INSTALL IDENTIFICATION PRODUCTS CENTERED, LEVEL, AND PARALLEL WITH LINES OF ITEM 1. WIRING PROVISIONS: TERMINAL SCREWS FOR SIDE WIRING AND SCREW ACTUATED BINDING D. INSTALL ENCLOSED SWITCHES PLUMB. BEING IDENTIFIED. CLAMP FOR BACK WIRING WITH SEPARATE GROUND TERMINAL SCREW. E. EXCEPT WHERE INDICATED TO BE MOUNTED ADJACENT TO THE EQUIPMENT THEY SUPPLY, D. SECURE NAMEPLATES TO EXTERIOR SURFACES OF ENCLOSURES USING STAINLESS STEEL B. STANDARD WALL SWITCHES: INDUSTRIAL SPECIFICATION GRADE, 20 A, 120/277 V WITH MOUNT ENCLOSED SWITCHES SUCH THAT THE HIGHEST POSITION OF THE OPERATING HANDLE SCREWS AND TO INTERIOR SURFACES USING SELF-ADHESIVE BACKING OR EPDXY CEMENT. STANDARD TOGGLE TYPE SWITCH ACTUATOR AND MAINTAINED CONTACTS; SINGLE POLE DOES NOT EXCEED 79 INCHES ABOVE THE FLOOR OR WORKING PLATFORM. E. INSTALL SELF-ADHESIVE LABELS AND MARKERS TO ACHIEVE MAXIMUM ADHESION, WITH NO SINGLE THROW, DOUBLE POLE SINGLE THROW, THREE WAY, OR FOUR WAY AS INDICATED ON CONSULTANT: BUBBLES OR WRINKLES AND EDGES PROPERLY SEALED. THE DRAWINGS. SECTION 26.51.00 F. SECURE RIGID SIGNS USING STAINLESS STEEL SCREWS. 1.04 RECEPTACLES G. MARK ALL HANDWRITTEN TEXT, WHERE PERMITTED, TO BE NEAT AND LEGIBLE. INTERIOR LIGHTING A. RECEPTACLES - GENERAL REQUIREMENTS: SELF-GROUNDING, COMPLYING WITH NEMA WD 1 SECTION 26.24.16 AND NEMA WD 6, AND LISTED AS COMPLYING WITH UL 498, AND WHERE APPLICABLE, FS PART 1 PRODUCTS PANELBOARDS W-C-596; TYPES AS INDICATED ON THE DRAWINGS. 1. WIRING PROVISIONS: TERMINAL SCREWS FOR SIDE WIRING OR SCREW ACTUATED BINDING 1.01 LUMINAIRES PART 1 PRODUCTS CLAMP FOR BACK WIRING WITH SEPARATE GROUND TERMINAL SCREW. A. PROVIDE PRODUCTS THAT COMPLY WITH REQUIREMENTS OF NFPA 70. 1.01 MANUFACTURERS 2. NEMA CONFIGURATIONS SPECIFIED ARE ACCORDING TO NEMA WD 6. B. PROVIDE PRODUCTS THAT ARE LISTED AND LABELED AS COMPLYING WITH UL 1598, WHERE A. EATON CORPORATION: WWW.EATON.COM. 1.02 PANELS - GENERAL REQUIREMENTS B. CONVENIENCE RECEPTACLES: APPLICABLE. A. PROVIDE PRODUCTS C. PROVIDE PRODUCTS LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSE LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSE 1. STANDARD CONVENIENCE RECEPTACLES: INDUSTRIAL SPECIFICATION GRADE, 20A, 125V, INTENDED. INTENDED. NEMA 5-2OR; SINGLE OR DUPLEX AS INDICATED ON THE DRAWINGS. B. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS SUITABLE FOR CONTINUOUS OPERATION C. GFCI RECEPTACLES: D. UNLESS OTHERWISE INDICATED, PROVIDE COMPLETE LUMINAIRES INCLUDING LAMP(S) AND ALL UNDER THE FOLLOWING SERVICE CONDITIONS: 1. GFCI RECEPTACLES - GENERAL REQUIREMENTS: SELF-TESTING, WITH FEED-THROUGH SOCKETS, BALLASTS, REFLECTORS, LENSES, HOUSINGS AND OTHER COMPONENTS REQUIRED ' 1. ALTITUDE: LESS THAI) 6,600 FEET. PROTECTION AND LIGHT TO INDICATE GROUND FAULT TRIPPED CONDITION AND LOSS OF 'TO POSITION ENERGIZE AND PROTECT THE LAMP AND DISTRIBUTE THE LIGHT. SEAL 2. AMBIENT TEMPERATURE: • a. PANELBOARDS CONTAINING CIRCUIT BREAKERS: BETWEEN 23 DEGREES F AND 104 PROTECTION; LISTED AS COMPLYING WITH UL 943, CLASS A. E. UNLESS SPECIFICALLY INDICATED TO BE EXCLUDED, PROVIDE ALL REQUIRED CONDUIT, BOXES, WIRING, CONNECTORS, HARDWARE, SUPPORTS, TRIMS, ACCESSORIES, ETC. AS NECESSARY ��QF t�EWy DEGREES F. a. PROVIDE TEST AND RESET BUTTONS OF SAME COLOR AS DEVICE. FOR A COMPLETE OPERATING SYSTEM. C. SHORT CIRCUIT CURRENT RATING: 2. STANDARD GFCI RECEPTACLES: INDUSTRIAL SPECIFICATION GRADE, DUPLEX, 20A, 125V, P p W. 4 O D. MAINS: CONFIGURE FOR TOP OR BOTTOM INCOMING FEED AS INDICATED OR AS REQUIRED F. PROVIDE PRODUCTS SUITABLE TO WITHSTAND NORMAL HANDLING INSTALLATION AND O �Q. NEMA 5-20R, RECTANGULAR DECORATOR STYLE. y P Q �- FOR THE INSTALLATION. ♦ O 3. WEATHER RESISTANT GFCI RECEPTACLES: INDUSTRIAL SPECIFICATION GRADE DUPLEX 20A E. BRANCH OVERCURRENT PROTECTIVE DEVICES: REPLACEABLE WITHOUT DISTURBING SERVICE WITHOUT ANY DAMAGE, DISTORTION, CORROSION, FADING DISCOLORING, ETC. G. RECESSED LUMINAIRES: cc 125V NEMA 5-20R RECTANGULAR DECORATOR STYLE LISTED AND LABELED AS WEATHER ADJACENT DEVICES. 1. CEILING COMPATIBILITY: COMPLY WITH NEMA LE 4. n uj RESISTANT TYPE COMPLYING WITH UL 498 SUPPLEMENT SE SUITABLE FOR INSTALLATION IN �+ F. BUSSING: SIZED IN ACCORDANCE WITH UL 67 TEMPERATURE RISE REQUIREMENTS. Z �' 1. PROVIDE SOLIDLY BONDED EQUIPMENT GROUND BUS IN EACH PANELBOARD, WITH A DAMP OR WET LOCATIONS. H. LED LUMINAIRES: SUITABLE LUG FOR EACH FEEDER AND BRANCH CIRCUIT EQUIPMENT GROUNDING CONDUCTOR. D. ISOLATED GROUND RECEPTACLES: 1. COMPONENTS: UL 8750 RECOGNIZED OR LISTED AS APPLICABLE. �Op 09152S G. CONDUCTOR TERMINATIONS: SUITABLE FOR USE WITH THE CONDUCTORS TO BE INSTALLED. 1. STANDARD ISOLATED GROUND RECEPTACLES: ORANGE, INDUSTRIAL SPECIFICATION GRADE, 2. TESTED IN ACCORDANCE WITH IES LM-79 AND IES LM-80. A��ESSION� H. ENCLOSURES: COMPLY WITH NEMA 250, AND LIST AND LABEL AS COMPLYING WITH UL 50 DUPLEX, 20A, 125V, NEMA 5-20R, RECTANGULAR DECORATOR STYLE, LISTED AND LABELED 3. LED ESTIMATED USEFUL LIFE: MINIMUM OF 50,000 HOURS AT 70 PERCENT LUMEN AND UL 50E. AS ISOLATED GROUND AND COMPLYING WITH UL 498 SUPPLEMENT SE SUITABLE FOR MAINTENANCE, CALCULATED BASED ON IES LM-80 TEST DATA. 12/22/2022 1. ENVIRONMENT TYPE PER NEMA 250: UNLESS OTHERWISE INDICATED, AS SPECIFIED FOR THE INSTALLATION IN HOSPITAL AND MEDICAL SETTINGS. ISOLATED GROUND WIRE TO RECEPTACLE FOLLOWING INSTALLATION LOCATIONS: SHALL BE GREEN WITH YELLOW STRIPE. MOUNTING ORIENTATION SAME AS GENERAL 1.02 EMERGENCY LIGHTING UNITS 2. BOXES: GALVANIZED STEEL UNLESS OTHERWISE INDICATED, RECEPTACLES WITHIN SPACE. A. DESCRIPTION: EMERGENCY LIGHTING UNITS COMPLYING WITH NFPA 101 AND ALL REVISIONS: a. PROVIDE WIRING GLITTERS SIZED TO ACCOMMODATE THE CONDUCTORS TO BE INSTALLED. 1.05 WALL PLATES APPLICABLE STATE AND LOCAL CODES, AND LISTED AND LABELED AS COMPLYING WITH UL 3. FRONTS: 924, 09-26-2022 OL RX REVIEW#1 a. FRONTS FOR SURFACE-MOUNTED ENCLOSURES: SAME DIMENSIONS AS BOXES. A. WALL PLATES: COMPLY WITH UL 514D. B. OPERATION: UPON INTERRUPTION OF NORMAL POWER SOURCE OR BROWNOUT CONDITION 4. LOCKABLE DOORS: ALL LOCKS KEYED ALIKE UNLESS OTHERWISE INDICATED. 1. CONFIGURATION: ONE PIECE COVER AS REQUIRED FOR QUANTITY AND TYPES OF EXCEEDING 20 PERCENT VOLTAGE DROP FROM NOMINAL, SOLID-STATE CONTROL 09-27-2022 OL RX REVIEW#2 I. FUTURE PROVISIONS: PREPARE ALL UNUSED SPACES FOR FUTURE INSTALLATION OF CORRESPONDING WIRING DEVICES. AUTOMATICALLY SWITCHES CONNECTED LAMPS TO INTEGRAL BATTERY POWER FOR MINIMUM 09-27-2022 OL Rx REVIEW#3 DEVICES INCLUDING BUSSING, CONNECTORS, MOUNTING HARDWARE AND ALL OTHER 2. SIZE: STANDARD. OF 90 MINUTES OF RATED EMERGENCY ILLUMINATION, AND AUTOMATICALLY RECHARGES REQUIRED PROVISIONS, 3. SCREWS: METAL WITH SLOTTED HEADS FINISHED TO MATCH WALL PLATE FINISH. BATTERY UPON RESTORATION OF NORMAL POWER SOURCE. 10-03-2022 PL POST 1.03 LIGHTING AND APPLIANCE PANELBOARDS A. DESCRIPTION: PANEL130ARDS COMPLYING WITH NEMA PB 1, LIGHTING AND APPLIANCE B. NYLON WALL PLATES: SMOOTH FINISH, HIGH-IMPACT THERMOPLASTIC. C. BATTERY: 12-23-2022 BID/PERMIT SET BRANCH CIRCUIT TYPE, CIRCUIT BREAKER TYPE, AND LISTED AND LABELED AS COMPLYING PART 2 EXECUTION 1. SIZE BATTERY TO SUPPLY ALL CONNECTED LAMPS, INCLUDING EMERGENCY REMOTE HEADS WITH UL 67; RATINGS, CONFIGURATIONS AND FEATURES AS INDICATED ON THE DRAWINGS. 2.01 INSTALLATION WHERE INDICATED. B. CONDUCTOR TERMINATIONS: D. DIAGNOSTICS: PROVIDE POWER STATUS INDICATOR LIGHT AND ACCESSIBLE INTEGRAL TEST 1. MAIN AND NEUTRAL LUG MATERIAL: ALUMINUM, SUITABLE FOR TERMINATING ALUMINUM OR A. PERFORM WORK IN ACCORDANCE WITH NECA 1 (GENERAL WORKMANSHIP) AND, WHERE SWITCH TO MANUALLY ACTIVATE EMERGENCY OPERATION. COPPER CONDUCTORS. APPLICABLE, NECA 130, INCLUDING MOUNTING HEIGHTS SPECIFIED IN THOSE STANDARDS 2. MAIN AND NEUTRAL LUG TYPE: MECHANICAL. UNLESS OTHERWISE INDICATED. E. PROVIDE LOW-VOLTAGE DISCONNECT TO PREVENT BATTERY DAMAGE FROM DEEP DISCHARGE. C. BUSSING: B. COORDINATE LOCATIONS OF OUTLET BOXES PROVIDED UNDER SECTION 26.05.33.16 AS 1.03 EXIT SIGNS 1. PHASE BUS CONNECTIONS: ARRANGED FOR SEQUENTIAL PHASING OF OVERCURRENT REQUIRED FOR INSTALLATION OF WIRING DEVICES PROVIDED UNDER THIS SECTION. A. DESCRIPTION: INTERNALLY ILLUMINATED EXIT SIGNS WITH LEDS UNLESS OTHERWISE PROTECTIVE DEVICES. 1. MOUNTING HEIGHTS: UNLESS OTHERWISE INDICATED, AS FOLLOWS: INDICATED; COMPLYING WITH NFPA 101 AND ALL APPLICABLE STATE AND LOCAL CODES, 2. PHASE AND NEUTRAL BUS MATERIAL: ALUMINUM. AND LISTED AND LABELED AS COMPLYING WITH UL 924. 3. GROUND BUS MATERIAL: ALUMINUM. a. WALL SWITCHES: 48 INCHES ABOVE FINISHED FLOOR. DRAWING BY: SGC D. CIRCUIT BREAKERS: THERMAL MAGNETIC BOLT-ON TYPE UNLESS OTHERWISE INDICATED. b. RECEPTACLES: 18 INCHES ABOVE FINISHED FLOOR OR 6 INCHES ABOVE COUNTER. 1. NUMBER OF FACES: SINGLE OR DOUBLE AS INDICATED OR AS REQUIRED FOR THE INSTALLED LOCATION. E. ENCLOSURES: CHECKED BY: E(, 1. PROVIDE SURFACE-MOUNTED OR FLUSH-MOUNTED ENCLOSURES AS INDICATED. C. INSTALL WIRING DEVICES IN ACCORDANCE WITH MANUFACTURER S INSTRUCTIONS. 2. DIRECTIONAL ARROWS: AS INDICATED OR AS REQUIRED FOR THE INSTALLED LOCATION. 2. PROVIDE CLEAR PLASTIC CIRCUIT DIRECTORY HOLDER MOUNTED ON INSIDE OF DOOR. D. INSTALL PERMANENT BARRIER BETWEEN GANGED WIRING DEVICES WHEN VOLTAGE BETWEEN B. SELF-POWERED EXIT SIGNS: 1.04 OVERCURRENT PROTECTIVE DEVICES ADJACENT DEVICES EXCEEDS 300 V. DATE: 09-22-2022 1. OPERATION: UPON INTERRUPTION OF NORMAL POWER SOURCE OR BROWNOUT CONDITION A. MOLDED CASE CIRCUIT BREAKERS: E. WHERE REQUIRED, CONNECT WIRING DEVICES USING PIGTAILS NOT LESS THAN 6 INCHES EXCEEDING 20 PERCENT VOLTAGE DROP FROM NOMINAL, SOLID-STATE CONTROL JOB NUMBER: 022139 1. DESCRIPTION: QUICK-MAKE, QUICK-BREAK, OVER CENTER TOGGLE, TRIP-FREE, LONG. DO NOT CONNECT MORE THAN ONE CONDUCTOR TO WIRING DEVICE TERMINALS. AUTOMATICALLY SWITCHES CONNECTED LAMPS TO INTEGRAL BATTERY POWER FOR MINIMUM TRIP-INDICATING CIRCUIT BREAKERS LISTED AND LABELED AS COMPLYING WITH UL 489, AND F. CONNECT WIRING DEVICES BY WRAPPING CONDUCTOR CLOCKWISE 3/4 TURN AROUND SCREW OF 90 MINUTES OF RATED EMERGENCY ILLUMINATION, AND AUTOMATICALLY RECHARGES TITLE: FEATURES AS INDICATED ON THE DRAWING. COMPLYING WITH FS W-C-375 WHERE APPLICABLE; RATINGS, CONFIGURATIONS, AND ELECTRICAL TERMINAL AND TIGHTENING TO PROPER TORQUE SPECIFIED BY THE MANUFACTURER. WHERE BATTERY UPON RESTORATION OF NORMAL POWER SOURCE. 2. INTERRUPTING CAPACITY: PRESENT, DO NOT USE PUSH-IN PRESSURE TERMINALS THAT DO NOT RELY ON 2. DIAGNOSTICS: PROVIDE POWER STATUS INDICATOR LIGHT AND ACCESSIBLE INTEGRAL TEST a. PROVIDE CIRCUIT BREAKERS WITH INTERRUPTING CAPACITY AS REQUIRED TO PROVIDE SCREW-ACTUATED BINDING. SWITCH TO MANUALLY ACTIVATE EMERGENCY OPERATION. SPECIFICATIONS THE SHORT CIRCUIT CURRENT RATING INDICATED, BUT NOT LESS THAN: G. UNLESS OTHERWISE INDICATED, CONNECT WIRING DEVICE GROUNDING TERMINAL TO BRANCH 3. PROVIDE LOW-VOLTAGE DISCONNECT TO PREVENT BATTERY DAMAGE FROM DEEP DISCHARGE. 1 10,000 RMS SYMMETRICAL AMPERES AT 240 VAC OR 208 VAC. CIRCUIT EQUIPMENT GROUNDING CONDUCTOR AND TO OUTLET BOX WITH BONDING JUMPER. 1.04 BALLASTS AND DRIVERS SHEET NUMBER: b. FULLY RATED SYSTEMS: PROVIDE CIRCUIT BREAKERS WITH INTERRUPTING CAPACITY NOT H. INSTALL WIRING DEVICES PLUMB AND LEVEL WITH MOUNTING YOKE HELD RIGIDLY IN PLACE. A. BALLASTS/DRIVERS - GENERAL REQUIREMENTS: LESS THAN THE SHORT CIRCUIT CURRENT RATING INDICATED. I. INSTALL WALL SWITCHES WITH OFF POSITION DOWN. CVS HAS DEVELOPED SPECIAL PRICING AND READILY AVAILABLE STOCK WITH 3. THERMAL MAGNETIC CIRCUIT BREAKERS: FOR EACH POLE, FURNISH THERMAL INVERSE TIME 1. PROVIDE BALLASTS CONTAINING NO POLYCHLORINATED BIPHENYLS (PCBS). THE NAI PREFERRED SUPPLIER: TRIPPING ELEMENT FOR OVERLOAD PROTECTION AND MAGNETIC INSTANTANEOUS TRIPPING J. INSTALL VERTICALLY MOUNTED RECEPTACLES WITH GROUNDING POLE ON TOP AND - WIEDENBACH-BROWN Co, INC. ELEMENT FOR SHORT CIRCUIT PROTECTION. HORIZONTALLY MOUNTED RECEPTACLES WITH GROUNDING POLE ON LEFT. 2. MINIMUM EFFICIENCY/EFFICACY: PROVIDE BALLASTS COMPLYING WITH ALL CURRENT PHONE: (781)769 9868 NEW YORKALTERATION WARNING STATEMENT: APPLICABLE FEDERAL AND STATE BALLAST EFFICIENCY/EFFICACY STANDARDS. El 01 4. MULTI-POLE CIRCUIT BREAKERS: FURNISH WITH COMMON TRIP FOR ALL POLES. EMAIL: CVSSUPPORT®WBLIGHT.COM IT IS A VIOLATION OF THE NEW YORK EDUCATION LAW,ARTICLE 145,SECTION COMMENTS: 0 3. ELECTRONIC BALLASTS/DRIVERS: INRUSH CURRENTS NOT EXCEEDING PEAK CURRENTS - NESCO, INC. 7209 FOR ANY PERSON,UNLESS THE INDIVIDUAL IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AN ITEM IN J EMAIL : CVSPLANS©fNEEDHAMELECTRIC.COM ANY WAY.IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF o SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. PANELBOARD: C (ETR) FED FROM: MDP LINE-SIDE LUGS:MECHANICAL RISER DIAGRAM NOTES ABBREVIATION LEGEND BUS AMPS:225A AIC RATING: N/A EQUIPMENT GROUND BUS MAIN SIZE/TYPE:MLO MOUNTING: SURFACE 1. ALL EQUIPMENT SHOWN IS EXISTING TO 2. PRIOR TO START OF WORK TRACE THE VOLTS/PHASE:208Y/1 20V,3PH,4W SERVES: CVS REMAIN UNLESS OTHERWISE NOTED. THIS EXISTING BRANCH CIRCUITRY TO THE A / AMP AMPERE JB JUNCTION BOX SECTION:1 LOCATION: Ell RM RISER DIAGRAM WAS DEVELOPED THROUGH EXISTING ELECTRICAL EQUIPMENT AS AC ALTERNATING CURRENT KVA KILOVOLT-AMPS " CKT DESCRIPTION VOLTAMPS/PHASE 1MR BKR P P BKR VVIR VOLTAMPS/PHASE I DESCRIPTION CKT FIELD SURVEYS OF EXISTING CONDITIONS. NECESSARY IN ORDER TO CONFIRM THE AFF ABOVE FINISH FLOOR KW KILOWATT NO. A B C I NO.I AMP I All NO. I A B I C I NO. IT IS INCLUDED IN THIS SET TO PROVIDE CIRCUITS BEING REUSED OR MODIFIED AS AWG AMERICAN WIRE GAUGE LTG LIGHTING ac%%yr"' THE CONTRACTOR WITH AN NOTED IN THE PLANS. RE-LABEL ALL C CONDUIT MCB MAIN CIRCUIT BREAKER EX 1 EXISTING LOAD 500 EX 20 1 20 EX 500 EXISTING LOAD 2 EX UNDERSTANDING OF THE OVERALL NEW REUSED AND MODIFIED CIRCUIT CB CIRCUIT BREAKER MLO MAIN LUGS ONLY EX 3 EXISTING LOAD 500 EX 20 1 1 1 20 EX 500 EXISTING LOAD 4 EX EX 5 EXISTING LOAD 500 EX CKT CIRCUIT NEC NATIONAL ELECTRICAL CODE 20 1 1 20 EX 500 EXISTING LOAD 6 EX EXISTING ELECTRICAL DISTRIBUTION BUT IS BREAKERS WHEN COMPLETE. PROVIDE NEW EF EXHAUST FAN RTU ROOFTOP UNIT NOT MEANT TO BE ALL INCLUSIVE OF ALL PANEL DIRECTORIES FOR EACH MODIFIED EX 7 EXISTING LOAD 500 Ex 20 1 1 20 EX 500 EXISTING LOAD 8 EX DISTRIBUTION EQUIPMENT AS NOT ALL ELECTRICAL PANEL ONCE EACH BRANCH GFI GROUND FAULT CIRCUIT INTERRUPTER TELE TELEPHONE Reset + Rx Di ital Screen Ex 9 EXISTING LOAD 500 EX 20 1 1 20 EX 500 EXISTING LOAD 10 Ex FEEDERS WERE LABELED. CIRCUIT HAS BEEN TRACED FROM THE GRD GROUND TYP TYPICAL EX 11 EXISTING LOAD 500 EX 20 1 1 20 EX 500 EXISTING LOAD 12 EX PANEL. HP HORSEPOWER V VOLT Expansion + P oto EX 13 EXISTING LOAD 500 EX 20 1 1 20 EX 500 EXISTING LOAD 14 EX IG ISOLATED GROUND VA VOLT-AMPERE Ex 15 EXISTING LOAD 500 EX 20 1 1 20 EX 500 EXISTING LOAD 16 EX 3. FIELD VERIFY ALL ELECTRICAL EQUIPMENT XFMR TRANSFORMER W WATT Ex 17 EXISTING LOAD 500 EX 20 1 1 20 EX 500 EXISTING LOAD 18 Ex SIZES, RATINGS, FEEDERS, CIRCUITS, DISC SW DISCONNECT SWITCH WP WEATHERPROOF STORE NUMBER: 3105 EX 19 EXISTING LOAD 500 EX 20 1 1 20 EX 500 EXISTING LOAD 20 Ex CONDUIT SIZES, CONDUIT ROUTING ETC. FU FUSE N 21 COKE FLM 500 12 20 1 1 SPACE 22 Ex NOTIFY ENGINEER OF ANY DISCREPANCIES 9870 MAIN ROAD N 23 PEPSI FLM 500 1 12 20 1 1 1 SPACE 24 EX OF EXISTING ELECTRICAL SYSTEM. MATTITUCK, NY 11952 N 25 RCPT-POWER POLE 500 12 20 1 1 SPACE 26 EX SYMBOL LEGEND PROJECT TYPE: (72 & 182) N 27 RCPT-POWER POLE 2 500 12 20 1 1 SPACE 28 EX N 29 RCPT-POWER POLE 3 500 12 20 1 1 SPACE 30 EX CONTRACTOR RESPONSIBILITIES SYMBOL DESCRIPTION MOUNTING ll 31 RCPT-ACO FRONT 500 12 20 1 1 SPACE 32 EX HEIGHT EX 33 SPACE 1 1 SPACE 34 EX EX 35 SPACE 1 1 SPACE 36 EX 1. AOR TO DO DUE DILIGENCE ON ALL DUPLEX RECEPTACLE 18" AFF CS PROJECT NUMBER: 165265 EX 37 SPACE 1 1 SPACE 38 EX EXISTING SPACES FOR ANNUNCIATORS AND (0-- QUAD RECEPTACLE 18" AFF Ex 39 SPACE 1 1 SPACE 40 EX PROBE LOCATIONS. GCT VERIFY LOCATIONS WITH LOCAL FIRE MARSHALL Ill DUPLEX RECEPTACLE WITH ISOLATED GROUND 18" AFF EX 41 ISPACE 1 1SPACE 42 Ex OR REVIEWER. QUAD RECEPTACLE WITH ISOLATED GROUND 18" AFF ARCHITECT OF RECORD' SUBTOTAL 1 3,000 1 2,500 1 2,500 1 1 2,000 1 1,500 1 1,500 1 SUBTOTAL GROUND FAULT CURRENT INTERRUPTER TYPE RECEPTACLE AS NOTED TOTAL PHASE A-VA 5,000 LOAD CONN.VA DF LOAD CONN.VA DF AMPS 42 COOLING [C] 1.00 REFRIG [F] 1.00 �+ GROUND FAULT INTERRUPTER QUAD RECEPTACLE OUTLET AS NOTED TOTAL PHASE B-VA 4,000 HEATING [H] 0 SIGNAGE [S] 1.25 EMS NOTES ® SPECIAL RECEPTACLE AS NOTED AS NOTED AMPS 33 LIGHTING [L] 1.25 KITCHEN [K] 1.00 TOTAL PHASE C -VA 4,000 RECEPTACLES [R] 1,500 1.0/.5 EXISTING [E] 1.00 DO NOT CONNECT THE FOLLOWING ITEMS INTO FLOOR MTD QUAD RECEPTACLE HUBBEL #CR20WHI W/RACO #189 BOX & FLOOR MTD THE EMS PANEL: CIRCUITS THAT ARE INDICATED TO BE ® METAL COVER RACO #9070 AMPS 33 MOTORS [M] 1.00 LRG MOTOR 1.25 TOTAL DEMAND . PHOTO LAB EQUIPMENT CONNECTED TO THE EMS WERE BASED ON THE TOTAL Pill-VA 13,000 SUPPHEAT [U] 1.00 SHOWWND[W] 1.25 13,000 v . FREEZERS, COOLERS, REFRIGERATORS EXISTING PANEL SCHEDULES AND NEW WORK. 0 CEILING DUPLEX RECEPTACLE CEILING MTD SBLM AMPS 36 MISC EQUIP [Z] 11,500 1.00 LTG TRACK 1.00 36 A . ICE MERCHANDISER ADDITIONAL CIRCUITS MAY BE REQUIRED TO BE Oj JUNCTION BOX W/COVERPLATE - WALL MOUNTED AS NOTED 545 West 45th Street 4th Floor PANELBOARD NOTES FAST LANE MERCHANDISE (FLM) CONNECTED TO THE EMS PER THE CVS EX-EXISTING N-PROVIDE NEW CKT Bill ATM REQUIREMENTS. DO NOT REUSE AN EMERGENCY ® MUD RING AS NOTED New York, NY 10036 IG-ISOLATED GROUND CIRCUIT • DIABETES CARE. LIGHTING/EMS CONTROLLED CIRCUIT. PD POWER DROP. REF DETAIL SHEET AS NOTED T: 212.995.5600 • VIDEO TDROPS IN RETAIL AREA p PUSHBUTTON AS NOTED www.sblm.com • POWER DROPS Ill PANELBOARD AS NOTED ll DISCONNECT SWITCH AS NOTED CONSULTANT ENGINEER Version 2.12 < HDMI PORT AS NOTED Short-Circuit and Voltage Drop Calculations Q1 (1)SINGLE DATALE INFO6MATIONONUT CEPLATE (WHITE) 18" AFF UON SINDistances are for calculation purposes only and shall not be used for contractor takeoffs nor bidding-Contractor shall notify Engineer of anyfield condition that results in a change of 10%or greater circuit distance (1) CATEGORY SE MODULAR JACKS (BLACK) TO STORE RACK (5) BLANK INSERTS (WHITE) go The followingcalculations are based on the"Point-b -Point'method where: VOLTAGE DROP 30 : CONSULTING Y ( ) ENGINEERS ISC(2)=ISC(1)x M(1) M=1/(1+f) Feeder: f(3o)= 1.732 x L x Isc XFMR: f(3o)= IP(sca)x Vp x 1.73 x%Z ISiscal= Vp x M X IP("m %VD= ((R x cos(arccos(pf))+X x sin (arccos(pf)))x L/#x I x 1.73)/E2+1 Q 2 DATA & 1 VOICE INFORMATION OUTLET 240 WEST 37TH STREET,3RD FLOOR 18 AFF UON ISC ISI=short circuit current at fault point 1 C x E 100,000 x KVA Vs VOLTAGE DROP(10): (1) SINGLE GANG 6-POSITION FACEPLATE (WHITE) NEW YORK,NY 10018 ISC(2)=short circuit current at fault point 2 Feeder: f(1°)= 2 x L x Isc XFMR: f(10)= IP(sca)x Vp x%Z %VD= ((R x cos(arccos(ii+X x sin(arccos(pf)))x 2 x L/#x 1)/E (2) CATEGORY SE MODULAR JACKS (BLACK) TO STORE RACK TEL 212.413.8400 (1) CATEGORY SE MODULAR JACKS (GRAY) TO WHITE CABINET www.hny-ong.com C x E 100,000 x KVA (3) BLANK INSERTS (WHITE) 2250003925 E= Line to line volts THREE PORT INFORMATION OUTLET » IP= Primary short circuit current Q3 (1) SINGLE GANG 6-POSITION FACEPLATE (WHITE) 18 AFF UON Vp= Primaryvoltage 3) CATEGORY 6 MODULAR JACKS (BLACK) TO STORE RACK IS= Secondary short circuit current %VD CUM= Cumulative Voltage Dropfrom FaultPointl to Fault Point# (3) BLANK INSERTS (WHITE) Vs= Secondaryvoltage R= resistance in ohms per LF CONSULTANT' L= Length of circuit X= reactances in ohms per LF Q4+1 4 DATA & 1 VOICE INFORMATION OUTLET 18" AFF UON C= "C"Factor from Bussman table where "C"=1 /impedance per linearfoot (1) SINGLE GANG 6-POSITION FACEPLATE (WHITE) Feeder Types: NM-Non Magnetic Conduit, M-Magnetic Conduit,FB-Feeder Busway, PB-Plug-in Busway,TX-Transformer (4) CATEGORY SE MODULAR JACKS (BLACK) TO STORE RACK (1) CATEGORY SE MODULAR JACKS (GRAY) TO WHITE CABINET (1) BLANK INSERTS (WHITE) System Voltage:48OY/277V-3 phase 5 DATA & 1 VOICE INFORMATION OUTLET Q 5+1 18" AFF UON Fault Source Source Feeder Ill Circuit Load Conductor Transformer Fault Voltage Cumulative Fault (1) SINGLE GANG 6-POSI1ION FACEPLATE (WHITE) Conductor Busway Circuit Load Point Bus/Feeder Description (Fault Phase Isc Conduit Material Quantity of Parallel Sets and 'C'Value 'C'Value Voltage Length Power (Amperage) Resistance Reactance Arccos (pt) Type Degree kVA New Existing Secondary Tap f M Current Drop Voltage Point (5) CATEGORY SE MODULAR JACKS (BLACK) TO STORE RACK (F#) Point) (amps) Type/TX Bus/Phase&Neutral Size (E) (L) Factor(pf) (R) (X) EEdlans) Rise Xfmr Z Xfmr Z Voltage Setting (amps) (%VD) Drop(%VD) (F#) (1) CATEGORY SE MODULAR JACKS (GRAY) TO WHITE CABINET 1 Utility Service Point 13,431 atthe secondaryofthe utilitytransformer Source Isc+6X Motor Contribution = 13,911 1 SECURITY CAMERA INFORMATION OUTLET Motor Contribution 80 The connected full load motor amps(includes compressors)on the system aCAM RSURFACE HOUSING BOX AS NOTED CATEGORY 2 CT BABINET 1 3 13,911 NM CU 2 Set(s)of 500 26706 -- 208 70 0.9 600 0.000027 0.000039 0.451027 0.152 0.87 12,077 -0.72% -0.72% 2 (1) Y (1) CATEGORY 6 MODULAR JACKS (BLACK) TO STORE RACK 3 MAIN DISCONNECT 2 3 12,077 NM CU 2 Set(s)of 500 26706 -- 208 5 0.9 600 0.000027 0.000039 0.451027 0.009 0.99 11,965 -0.05% -0.77% 3 (1) BLANK INSERTS (WHITE) 4 PNL. MDP 3 3 11,965 M CU 2 Set(s)of 500 22185 - 208 10 0.9 600 0.000029 0.000048 0.451027 0.022 0.98 11,702 -0.12% -0.89% 4 5 PNL.A 4 3 11,702 M CU 1 Set(s)of 4/0 AWG 15082 - 208 5 0.9 100 0.000063 0.000051 0.451027 0.032 0.97 11,336 -0.03% -0.92% 5 AFF ABOVE FINISHED FLOOR �1 6 PNL.B 4 3 11,702 M CU 1 Set(s)of 4/0 AWG 15082 - 208 10 0.9 100 0.000063 0.000051 0.451027 0.065 0.94 10,992 -0.07% -0.96% 6 VEAL' 7 PNL. C 4 3 11,702 M CU 1 Set(s)of 1 AWG 7293 - 208 15 0.9 35 0.000160 0.000057 0.451027 0.200 0.83 9,748 -0.07% -0.97% 7 AFG ABOVE FINISHED GRADE XX REFER TO ELECTRICAL NOTES (GOF t+E1'V $M MOTOR-RATED DISCONNECT SWITCH AS NOTED #XW WIRING SIZE ♦ ~ t o DOUBLE GANG PLASTER RING, RACO #769 FOR 5/8" DRYWALL m NOTE: UNLESS OTHERWISE NOTED ALL OUTLETS & JUNCTION BOXES TO BE LOCATED 18" A.F.F. RECEPTACLES Z e V TO BE "LEVITON" #5362A-W (ALL DEVICES TO BE WHITE). REVIEW ELECTRICAL NOTES TO VERIFY Q 08152 CONDITIONS PER ELECTRICAL LEGEND. �o q MOUNTING HEIGHT IS FROM FINISHED FLOOR TO CENTERLINE OF DEVICE OR OUTLET. HEIGHT MAY VARY �FESS10Nr M TO COINCIDE WITH BUILDING CONSTRUCTION. 12/22/2022 im RISER DIAGRAM KEY NOTES REVISIONS: 09-26-2022 OL Rx REVIEW#1 OEXISTING TO REMAIN PAD-MOUNTED, THREE PHASE UTILITY TRANSFORMER WITH 09-27-2022 OL Rx REVIEW#2 SECONDARY OF 208Y/12OV. O EXISTING TO REMAIN UTILITY C.T. CABINET. 09-27-2022 OL Rx REVIEW#3 O EXISTING TO REMAIN UTILITY METER. 10-03-2022 PL POST ® EXISTING TO REMAIN 80OA/3P ENCLOSED CIRCUIT BREAKER. 12-23-2022 BID/PERMIT SET U O5 EXISTING TO REMAIN GROUNDING ELECTRODE SYSTEM. 0- S RISER DIAGRAM - FEEDER SCHEDULE NOTES EXISTING WIREWAY ---------- -----------------• F1 EXISTING TO REMAIN 800A SERVICE FEEDER, (2) 4" C, EACH W/ (4)-500 kcmil. - F2 EXISTING TO REMAIN 800A ISOLATED GROUND FEEDER, (2) 4" C, EACH W/ (4)-500 DRAWING BY: SGC F4 LU kcmil, (1)#2/0 G, (1)#2/0 IG F3 EXISTING TO REMAIN 225A FEEDER, (4)#4/0, (1)#4 G, 2-1/2" C. CHECKED BY: EG 4 F DATE: 09-22-2022 2 F5 F3 Fs F3 F4 W ��• F4 EXISTING TO REMAIN 125A ISOLATED GROUND FEEDER, (4)#1, (1)#6 G, (1)#6 IG, PK JOB NUMBER: 022139 (ETR) (ETR) O W OF3 MDP EMS (ETR) (ETR) (ETR) LW-- TITLE: •� SYMBOLS RISER DIAGRAM 3 F PANEL PANEL PANEL F1 F1 2 SECTION B" C. tY EXTERIOR MEZZANINE ( ) (2 SECTION) F-- ~ C-) SAND SCHEDULES F, W ® SHEET NUMBER: 5 0 ELECTRICAL NEW YORK ALTERATION WARNING STATEMENT: E2 2 PANELBOARD D LAYOUT IT IS A VIOLATION OF THE NEW YORK EDUCATION LAW,ARTICLE 145,SECTION } 1 ELECTRICAL RISER DIAGRAM (EXISTING) TRICA7209 FOR ANY PERSON, UNLESS THE INDIVIDUAL IS ACTING UNDER THE COMMENTS: fDIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AN ITEM IN E2 SCALE: NOT TO SCALE ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE E2 SCALE: 1/4"4-0'-O ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF oSUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. LIGHTING FIXTURE SCHEDULE GENERAL LIGHTING NOTES 1. REPAIR/REPLACE ALL DAMAGED OR (ALARM, MUSIC, CAMERAS, ETC.) IN TYPE DESCRIPTION MOUNTING VOLT VA WATTS LAMPS REMARKS/NOTES INOPERABLE EXISTING EXIT AND AREAS OF CEILING REMOVAL/REWORK. = EMERGENCY LIGHT FIXTURES AND INDEPENDENTLY SUPPORT EQUIPMENT K LED MONOPOINT WITH ELLIPTICAL LENS SURF MTD 120 33 29.5 LED INCLUDED WITH UNIT AIM FIXTURE DIRECTLY AT CENTER OF PHARMACY RECONNECT. UNTIL CEILING WORK IS COMPLETE AND SISTEMALUX #1620C-SPSOO9160 SIGNAGE OR GONDOLA ENDCAP WHERE APPLICABLE. REINSTALL. COORDINATE WITH CVS PM 2. CLEAN ALL LIGHTING FIXTURES. FOR PLACEMENT. ID in RELAMP AS NEEDED. &ho% �mar%vi 5. AOR TO DO DUE DILIGENCE ON ALL 3. ALL LIGHTING FIXTURES AND LAMPS EXISTING SPACES FOR ANNUNCIATORS PROVIDED AND INSTALLED BY THE EC. AND PROBE LOCATIONS. GC TO VERIFY Reset + Rx Di ital Screen LOCATIONS WITH FIRE MARSHAL OR Expansion + P oto 4. GC SHALL BE RESPONSIBLE TO REVIEWER. MAINTAIN ALL AUXILIARY SYSTEMS STORE NUMBER: 3105 9870 LIGHTING & CONTROLS SYMBOLS LEGEND MATTITUICK, NYD11952 SYMBOL DESCRIPTION HEIGHT PROJECT TYPE: (72 & 182) ®� (NEW & EXISTING) 21 FLUORESCENT TROFFER E . REEL.F. REEL. COL F. REF. REE REFF. 4' FLUORESCENT STRIP LIGHT CS PROJECT NUMBER: 165265 ® 1'X4' FLUORESCENT TROFFER A 4' WALL/PARAWASH LIGHT ARCHITECT OF RECORD' M N'S o NEW LED MONOPOINT LIGHT FIXTURE %k TC ILET HALL 07 109 � BATTERY-POWERED EMERGENCY LIGHT '?� •, 0 ®--1-- coo BATTERY—POWERED EXIT SIGN SBLM COL. REF. $s OCCUPANCY SENSOR (COOPER CONTROLS 42" AFF LION 545 West 45th Street 4th Floor o #ONW—D-1001—DMV—W) SET TIME DELAY FOR 20 MINUTES New York, NY 10036 ELOECTRICAL VESTIBULE (�®�) OCCUPANCY TMECDELAY FOR(COOPER20 MNUTEONTROLS #OAC—P-0500—MV) T: 212.995.5600 WORK IN www.sblm.com L2 SHADSHADED 100 NO LABEL / ETR EXISTING TO REMAIN N NEW LIGHT FIXTURE R EXISTING TO BE RELOCATED D DEMOLISHED CONSULTANT ENGINEER' 0 'A M MODIFIED - FIXTURE BEING RELAMPED i LTIN BREAKROOM KEYED NOTES - LIGHTING NEW WORK ENGINEERSG INSTALL MONOPOINT LIGHT AT THE MINIMUM DISTANCE FROM 48" TO 53"' 240 WEST 37TH STREET,3RD FLOOR C5 0 ® L1 OFF THE VERTICAL SOFFIT. CENTER FIXTURES TO SIGNAGE AND SPACE THEM NEW YORK,NY 10018 5FT APART. TWIST THE FRONT FACE OF THE MONOPOINT LIGHT TO ALIGN TEL 212.413.8400 lo ® THE ELONGATED BEAM ACROSS THE SIGNAGE AND PROVIDE EVEN www.hny-eng.com ® CHECKOUT ILLUMINATION. CONNECT TO EMS ALONG WITH RETAIL LIGHTING. COORDINATE 2250003925 102 WITH ARCH INTERIOR ELEVATIONS FOR EXACT LOCATION. ENSURE PANEL AND UPSTREAM DISTRIBUTION EQUIPMENT HAVE SUFFICIENT CAPACITY TO POWER 0 ® NEW LOAD. RECEIVINGL2 RELOCATE EXISTING LIGHT FIXTURE. REUSE AND EXTEND EXISTING CIRCUIT AS CONSULTANT' AREA ® NEEDED. 10EiA NO CVS FIRE ALARM AND SECURITY VENDOR SHALL MODIFY, RELOCATE AND/OR ELECTRICAL PHOTO LAB PROVIDE ADDITIONAL CAMERAS, MOTION DETECTORS, SECURITY CAMERAS AND WORK IN 103 FIRE ALARM EQUIPMENT REQUIRED FOR COMPLETE AND OPERATIONAL SYSTEM FOR THE SCOPE OF WORK. COORDINATE WITH WALLS, CEILINGS, LIGHTS, SHADED AREA DIFFUSERS, OBSTRUCTIONS, ETC. IN ALL AREAS AFFECTED BY THE SCOPE OF WORK. NEW EQUIPMENT SHALL BE COMPATIBLE WITH THE EXISTING SYSTEM. 101 COL. REF. SEAL: ® ® P��o ,EF r0 L1 w y� P� K (N) ® ,► r � L1 n w K (N) ® ® ZS 081525 L1 A�FESS���r K N 12/22/2022 OFF z REVISIONS: 0 NO 09-26-2022 OL Rx REVIEW#1 ELEC1 RI \ WORK IN AL 09-27-2022 OL Rx REVIEW#2 \ SHAD D \ AREA 09-27-2022 OL Rx REVIEW#3 \ 10-03-2022 PL POST \ HOF. 12-23-2022 BID/PERMIT SET \ RETAIL MANAGER'S P kRMAGYOFFICE 110 \\ 104 U WIMA COL. REF. DRAWING BY: SGC WAITING 111 CHECKED BY: EG DATE: 09-22-2022 JOB NUMBER: 022139 TITLE: 1 OVERALL REMODEL LIGHTING PLAN E3 SCALE: 1/8" = 1'-0° LIGHTING PLAN SHEET NUMBER: NEW YORKALTERATION WARNING STATEMENT: E3 IT IS A VIOLATION OF THE NEW YORK EDUCATION LAW,ARTICLE 145,SECTION COMMENTS: 7209 FOR ANY PERSON, UNLESS THE INDIVIDUAL IS ACTING UNDER THE w DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE o NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF oSUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. TV 1. COORDINATE ALL FINAL LOCATIONS 7. (####VA) INDICATES LOAD BEING ADDED FOR POINTS OF ELECTRICAL SERVICE TO A CIRCUIT OR THE TOTAL AMOUNT JUNCTION BOXES, STUB—UPS, OF LOAD TO A PHOTOLAB RETAIL SIDE WALL DUPLEX RECEPTACLE 6 NEW CIRCUIT. - --- -- RECEPTACLES, TELE/DATA OUTLETS, SIDE a ETC.) WITH EQUIPMENT INSTALLER AND 8. MOUNT THE FOLLOWING ABOVE FINISH TM ;�r,r- r -- ��: . CVS REPRESENTATIVE PRIOR TO FLOOR: (2) DUPLEX RECEPTACLES ;:. �-E::: .,::.�:..,. .. . ...,.' ... ;... INSTALLATION. OUTLETS 18 TO 48 mharma^'t h u i i i i t i Q SWITCHES 36" TO 48" ,> „ RECEPTACLE 2. LABEL SPARE IN PANEL(S) OF ALL THERMOSTAT 36 TO 48 , ", F--- +--- ---r-- Reset + Rx Di ital Screen BELOW i� i ai ii i iii i I i i CIRCUITS TO BE ABANDONED FROM COUNTER III Ii ii i i I I I i I REMODEL OF STORE AND TURN 9. APPLIES TO ALL RELOCATED , , �___ +___� Expansion + P oto LED TV i i�I---=== T===--- i i �, BREAKERS TO THE OFF POSITION. EQUIPMENT, UNLESS NOTED NOTE: WHITE POWER OTHERWISE: REUSE AND EXTEND POLE WITH 3. ALL UNUSED WIRING IN CEILING /FLOOR STORE NUMBER: 3105 i�i ,i ii i i i i i i > FLOOR PROTECTED CIRCUIT FROM C) JUNCTION BOX TO i I �t ii i i I i I i I I SPACE SHALL BE PULLED BACK TO DEMOLITION TO NEW LOCATION BE TERMINATED 6" U� it4 4______1�__._:�_�� �._�_ ' SOURCE AND REMOVED. AS REQUIRED. ABOVE FINISHED i ° - ^ `� fi. `: .;:�•. .'.�:'':: :;:.. :•a`I:•::7 9870 MAIN ROAD CEILING. ---�,^�--- _• � :l _ _, .•.. ''r--```1 t._`= 4. REFER TO ARCHITECTURAL PLANS AND 10. APPLIES TO ALL NEW EQUIPMENT. MATTITUCK, NY 11952 WALL ELECTRICAL PLAN FOR DEMOLITION. UNLESS NOTED OTHERWISE: EQ EQ CONNECT TO EXISTING SPARE PROJECT TYPE: (72 & 182) LOW VOLTAGE 5. REUSE EXISTING CIRCUITS FROM CIRCUIT IN POWER PANELBOARD. CORD TRAY OUTLET REMOVED EQUIPMENT WHEN POSSIBLE, ENSURE PANELBOARD AND NOTES: ABANDONED CIRCUITS SHALL BE UPSTREAM DISTRIBUTION DUPLEX OUTLET — REFER TO ELEVATIONS FOR TV HEIGHTS. REMOVED BACK TO SOURCE. EQUIPMENT HAVE SUFFICIENT CS PROJECT NUMBER: 165265 POWERED BY © CAPACITY TO POWER NEW LOAD, MALE PLUG © 6. VERIFY ALL EXISTING PANEL LOADING IN FIELD AS REQUIRED PRIOR ANY NEW 11. APPLIES TO ALL DUPLEX OUTLETS WORK. ARCHITECT OF RECORD' TYPICAL TV MOUNTING ON COLUMNS IN RETAIL/SALES AREA: RELOCATE TO FACE DRIVE rT� ELECT PHOTOLAB ELEVATION 3 POWER POLE DETAIL 4 ELECTRICAL DETAIL AISLE. E4 SCALE: NTS Q4") SCALE: NTS = E4 SCALE NTS COORDINATE WITH FINAL MERCHANDISE PLAN FOR LOCATIONS OF EXISTING POWER POLES THAT ARE TO BE RELOCATED. EXTEND AND RECONNECT GONDOLA WIRING CHASE CIRCUITING AND DEVICES. SBLM MI COL. COL. COL. cOL. 545 West 45th Street 4th Floor REF. REF. REF. REF. REF. New York, NY 10036 CVS FIRE ALARM AND SECURITY VENDOR SHALL MODIFY, RELOCATE AND/OR T: 212.995.5600 PROVIDE ADDITIONAL CAMERAS, MOTION DETECTORS, SECURITY CAMERAS AND www.sblm.com FIRE ALARM EQUIPMENT REQUIRED FOR COMPLETE AND OPERATIONAL SYSTEM FOR THE SCOPE OF WORK. COORDINATE WITH WALLS, CEILINGS, LIGHTS, DIFFUSERS, OBSTRUCTIONS, ETC. IN ALL AREAS AFFECTED BY THE SCOPE OF M N'S WORK. NEW EQUIPMENT SHALL BE COMPATIBLE WITH THE EXISTING SYSTEM. CONSULTANT ENGINEER' TOILET HALL O7 109 KEYED NOTES - NEW WORK COL. CONSULTING REF. P1 PROVIDE POWER REQUIRED FOR PHOTOLAB AREA. REUSE AND EXTEND ENGINEERS NO PROTECTED CIRCUITS FROM DEMOLITION PHASE FOR NEW LOCATION AS 240 WEST 37TH STREET,3RD FLOOR �/ WORK RN AL REQUIRED. REFER TO DETAIL 2/E4 FOR MORE INFORMATION. NEW YORK,NY 10018 P5 SHADED TEL 212.413.8400 // I AREA VESTIBULE P2 RELOCATE EXISTING POWER POLE AS SHOWN ON FLOOR PLAN. EXTEND AND REUSE www.hny-eng.com P5 // I 100 PROTECTED CIRCUIT FROM DEMOLITION CIRCUIT TO NEW LOCATION AS REQUIRED. 2250003925 C-29 // I P5 o REFER TO DETAIL 3/E4 FOR MORE INFORMATION. P3 PROVIDE POWER FOR NEW AUTOMATED CHECKOUT (ACO). PROVIDE ISOLATED O C-25 I a EQUIPMENT GROUNDING CONDUCTOR. CONSULTANT RELOCATE POWER FOR DUPLEX PRINTER. PROVIDE NEW POWER POLE AS SHOWN ON FLOOR PLAN. REFER TO DETAIL 3/E4 FOR BREAKROOM / I MORE INFORMATION. 105 I C-21 O P6 RELOCATE POWER FOR ATM. Z/oo //// i C-23 P8 P7 RELOCATE POWER FOR POSTER PRINTER. CHECKOUT P8 PROVIDE POWER FOR NEW COKE FLM. 17102 O P3 P9 PROVIDE POWER FOR NEW PEPSI FLM. oo ��i/ RECEIVING O D ��� rml RELOCATE POWER FOR BLOOD PRESSURE MACHINE. P7 AREA I = P12 C-31P11 PROVIDE (2) DUPLEX RECEPTACLES. THE TOP OF THE RECEPTACLES SHALL 106A = - _ _ _ _ _ _ _ �`_ _— \ j i BE INSTALLED 3" BELOW THE TOP OF THE TV. COORDINATE RECEPTACLES SEAL' ,x� I AND TV ELEVATION WITH ARCHITECTURAL PLANS. CONNECT NEW WY vNO � y' I C RECEPTACLES TO NEAREST EXISTING CIRCUIT. ENSURE EXISTING CIRCUIT ��OE r�Eftiy ELECTRICAL I PHOTO LAB BEING CONNECTED TO IS NOT OVERLOADED. REFER TO DETAIL 4/E4 AND ,`1:► �p W. 103 ARCHITECTURAL ELEVATIONS FOR MORE INFORMATION. y QP AREAED ; I oo P4P12 PROVIDE NEW POWER FOR WECC. cc xui to RETAIL �L P13 RELOCATE POWER FOR ECC. ZJ, �? t � P13 g8152 COL. P14 RELOCATED EXISTING MONEYGRAM MACHINE. �OgO��S$1ON��• ;I — r 12/22/2022 P14 P1 A 0 0 REVISIONS: 03 09-26-2022 OL RX REVIEW#1 P2 I r 09-27-2022 OL RX REVIEW#2 09-27-2022 OL RX REVIEW#3 10-03-2022 PL POST ® 12-23-2022 BID/PERMIT SET P10 x Iv ® P2Ll I F c� I j a= I ELECTRICAL S HAD\\� WORK IN \\� I AREAED DRAWING BY: SGC \\\ — — CHECKED BY: EG \\\-- - - - - - - - - - - - - — - - -- — - - -- COL. \ J RE L REF. DATE: 09-22-2022 \ F.C-27 MANAGER'S P Kilmo 4 Y \ ,\-� ® 1 1 OFFICE JOB NUMBER: 022139 \\\ P2 �x' Q 104 P5 P2 TITLE: 1 P13 coL. ------------- POWER PLAN SHEET NUMBER: O WAITING P11 111 (1 NEW YORK ALTERATION WARNING STATEMENT: E4_ IT IS A VIOLATION OF THE NEW YORK EDUCATION LAW,ARTICLE 145,SECTION 1 OVERALL REMODEL POWER PLAN 7209 FOR ANY PERSON,UNLESS THE INDIVIDUAL IS ACTING UNDER THE COMMENTS: w DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AN ITEM IN E4 SCALE: 1/8" = 1'-0" ANY WAY.IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF oSUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. TM pharmacy Reset + Rx DiT tal Screen Expansion + Poto STORE NUMBER. 3105 9870 MAIN ROAD MATTITUCK, NY 11952 PROJECT TYPE: (72 & 182) CS PROJECT NUMBER: 165265 COMcheck Software Version COMcheckWeb COMcheck Software Version COMcheckWeb Section ARCHITECT OF RECORD' # Rough-In Electrical Inspection Complies? Comments/Assumptions Interior Lighting Compliance Certificate Inspection Checklist 8.4.2pID At least 50%of all 125 volt 15-and ;❑Complies Exception: Requirement does not apply. Nr n�( [EL10] 20-Amp receptacles are controlled by ❑Does Not ;_ Energy Code: 2020 NYStretch Energy Code - 90.1 (2016) Standard an automatic control device. :❑Not Observable; Requirements: 100.0% were addressed directly in the COMcheck software ;❑Not Applicable Project Information Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each 8.4.3 ;New buildings have electrical energy ❑Complies Exception: Requirement does not apply. requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception [ELii]z use measurement devices installed. ❑Does Not Energy Code: 2020 NYStretch Energy Code - 90.1 (2016) Standard is beingclaimed. Where compliance is itemized in a separate table, a reference to that table is provided. where tenant spaces exist, each ;❑Not Observable p p p 'tenant is monitored separately. In Project Title: CVS ;buildings with a digital control system ;❑NSBLM Applicable ; Project Type: Alteration Section ;the energy use is transmitted to to 545 West 45th Street 4th Floor # Plan Review Complies? Comments/Assumptions ;control system and displayed & Re .ID 'graphically. New York, NY 10036 Construction Site: Owner/Agent: Designer/Contractor: 4.2.2,8.7 'Plans,specifications, and/or ;❑Complies ;Requirement will be met. [PR6]2 calculations provide all information ;❑Does Not Additional Comments/Assumptions: T: 212.995.5600 9870 Main Rd. SBLM Henderson Engineers(HNY) with which compliance can be www.sblm.com Mattituck, New York 11952 545 W 45th St. 240 W 37th St. determined for the electrical systems ;❑Not Observable New York City, New York 10036 New York City, New York 10018 and equipment and document where ;❑Not Applicable 212-995-5600 212-413-8400 ;exceptions are claimed. Feeder Allowed Interior Lighting Power connectors sized in accordance with approved plans and branch circuits CONSULTANT ENGINEER' A B C D sized for maximum drop of 5%. Area Category Floor Area Allowed Allowed 10.4.7 New parking garages and new parking ;❑Complies ;Exception: Requirement does not apply. (ft2) Watts/ft2 Watts [PR38]3 lots powered by the energy services !❑Does Not j for a building, and with 10 or greater 1-Sales Area (Retail:Sales Area): Exempt parking spaces, provide either: 1. :❑Not Observable; Total Allowed Watts= N/A Panel capacity and conduit for the ;❑Not Applicable :future installation of minimum CONSULTING ENGINEERS Area Category Exemption Qualifications 208/240V 40-amp outlets for 5 j Connected Watts Total # Watts percent of the total parking spaces 240 WEST 37TH STREET,3RD FLOOR NEW YORK,NY 10018 Activity Area �and not less than two parking spaces; W TEL RK,NY 10018 413.8400 Pre-Alt. Repl./Added Pre-Alt. Post-Alt. for 2. Minimum 208/240V 40-amp outlets for 5 percent of the total www.hny-ong.com Sales Area (Retail: Sales Area. 9773 sq.ft.) 10160 88 10160.000 8825.000 parking spaces and not less than two j 2250003925 Exemption: Less than 20%connected lighting watts ;parking spaces. replacement. Additional Comments/Assumptions: Proposed Interior Lighting Power A B C D E Fixture ID : Description /Lamp/Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D) CONSULTANT' Fixture Fixture Watt. Sales Area (Retail: Sales Area 9773 sq ft )• Exempt Total Proposed Watts = N/A IL Interior Lighting Compliance Statement i Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed Interior lighting systems have been designed to meet the 2020 NYStretch Energy Code-90.1 (2016)Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Shawn Carnevale - Electrical Designer � 12/19/2022 Name-Title Signature Date SEAL: of t4e W4 0 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) r ccw Project Title: CVS Report date: 12/19/22 Project Title: CVS Report date: 12/19/22' Project Title: CVS Report date: 12/19/22' Z Data filename: Page 1 of 3 Data filename: Page 2 of 3 Data filename: Page 3 of 3 C� CoA 091 q�FESs10N�� 12/22/2022 REVISIONS: 09-26-2022 OL Rx REVIEW#1 09-27-2022 OL Rx REVIEW#2 09-27-2022 OL Rx REVIEW#3 10-03-2022 PL POST 12-23-2022 BID/PERMIT SET DRAWING BY: SGC CHECKED BY: EG DATE: 09-22-2022 JOB NUMBER: 022139 TITLE: ELECTRICAL ENERGY COMPLIANCE SHEET NUMBER: NEW YORK ALTERATION WARNING STATEMENT: EC1_ IT IS A VIOLATION OF THE NEW YORK EDUCATION LAW,ARTICLE 145,SECTION COMMENTS: 0 7209 FOR ANY PERSON, UNLESS THE INDIVIDUAL IS ACTING UNDER THE J DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF oSUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. GENERAL DEMOLITION NOTES 1. VISIT THE SITE TO VERIFY EXISTING CONDITIONS PRIOR TO SUBMISSION OF BID. NO ADDITIONAL COMPENSATION SHALL BE CONSIDERED FOR FAILURE TO OBSERVE THIS REQUIREMENT. 2. DISCONNECT AND REMOVE ALL ELECTRICAL WIRING AND EQUIPMENT AS REQUIRED WITHIN ALL AREAS TO BE RENOVATED. THIS SHALL INCLUDE BUT In NOT BE LIMITED TO FIXTURES, DEVICES, OUTLETS, SWITCHES, RECEPTACLES, ro& haummacy'm STARTERS, DISCONNECTS, PANELS, FEEDERS, ETC. 3, DISCONNECT AND REMOVE ALL EXISTING CIRCUITS TO MECHANICAL Reset + Rx Di ital Screen EQUIPMENT BEING REMOVED. REFER TO ALL MECHANICAL DEMOLITION DRAWINGS OR NOTES. Expansion + P Oto 4. WHERE ELECTRICAL ITEMS ARE REMOVED, ALL BRANCH DEVICE'S WIRING STORE NUMBER: 3105 SHALL BE REMOVED BACK TO PANEL SERVING THE EQUIPMENT. WHERE CIRCUITS SERVE ADDITIONAL DEVICES OR EQUIPMENT REMAINING, WIRING SHALL BE REMOVED BACK TO THE NEAREST ACTIVE JUNCTION BOX. 9870 MAIN ROAD 5. MAINTAIN CONTINUITY OF EXISTING CIRCUITS THAT ARE TO REMAIN IN MATTITUCK, NY 11952 OPERATION AND SCHEDULE FOR REFEEDING FROM NEW PANELBOARDS. PROJECT TYPE: (72 & 182) FORWARD FINDINGS TO ENGINEER FOR REVIEW AND COORDINATION. 6. ALL UNUSED CIRCUITS REMAINING AFTER REMOVALS SHALL BECOME SPARE IN PANELBOARDS, LABELED AS SPARE, AND SWITCHED TO THE OFF CS PROJECT NUMBER 165265 POSITION. 7. REFER TO ARCHITECTURAL DEMOLITION DRAWING FOR ADDITIONAL ARCHITECT OF RECORD' INFORMATION AND SCOPE OF DEMOLITION, 8. ALL MATERIALS AND EQUIPMENT REMOVALS SHALL BE DISPOSED OF AS DIRECTED BY THE OWNER OR THE ARCHITECT. 9. ALL EMPTY CONDUITS MUST HAVE PULLWIRES AND BE TAGGED PROPERLY. '. 10. TIE BACK ALL LOOSE WIRING (INCLUDING LOW VOLTAGE). + COL. COL. COL. COL. COL. 11. VERIFY ALL EXISTING CIRCUITS AFFECTED BY THIS WORK AND RELABEL SBLM REF. REF. REF. REF. REF. PANELBOARD SCHEDULES IN FIELD AS REQUIRED. 545 West 45th Street 4th Floor 12. VERIFY ALL EXISTING PANELBOARD LOADING AFFECTED BY THIS WORK IN New York, NY 10036 FIELD AS REQUIRED PRIOR TO ANY NEW WORK. T: 212.995.5600 13. REFER TO NEW LIGHTING PLAN AND ARCHITECTURAL CEILING DEMOLITION www.sblm.com PLAN FOR ADDITIONAL INFORMATION. N TOILET HALL KEY NOTES - DEMOLITION CONSULTANT ENGINEER: 07 109 0 O EXISTING LIGHT FIXTURE TO BE DEMOLISHED. REMOVE EXISTING LIGHT COL. FIXTURE, RACEWAY, CIRCUITRY AND CONTROLS, AND RELATED ACCESSORIES NOT BEING REUSED BACK TO SOURCE PANELBOARD OR NEAREST REMAINING ® I I I (D� ro� _ I REF. DEVICE. MAINTAIN EXISTING CIRCUITING AND CONTROLS FOR REMAINING CONSULTING o L _ _ _ _ L_#-Z_#=L— _ LIGHT FIXTURES. ENGINEERS 1 1 - - - _ __ __ - - _ _ _ ' _ _ _ 1 I 1 (D) 240 WEST 37TH NEW YORK,NY 1 3RD FLOOR T t -� - - ( ) NY 10018 r •� VESTIBULE O EXISTING LIGHT FIXTURE "EX2" TO BE RELOCATED/REINSTALLED. EXISTING TEL 212.413.8400 --- - -(�)°-- p)--- - - - - - - —=-1---- I - - ---r- r-- - I - - -r-- -I- 100 2 RELATED ACCESSORIES AND WIRING DEVICES MAY E REUSED IF IN GOOD www.hny-eng.com I I I I I I I ► _I I I I I I I CONDITION AND NEW DESIGN CRITERIA CAN BE MET; OTHERWISE REPLACE. 2250003925 ——-1- ——-1- — I- ——-1-— —— — — — -I- — — -I- I- — —i——— I- — — _i— — — EXTEND CIRCUITRY AND CONTROLS TO NEW LOCATION AS REQUIRED. F I I _ - I I I I I I H Fi I -- -T- - -T - --T---T --- --- T- - - T --- - - -� - -T-- - +R'_'� - --T-- - T --- I I I I I I I I I I I I I I I ( ) 1 I O - - T - - -T -- - -T-- - T - -- - -- T-- - r -- - - -- fi - - - t - - - - -t - - I 1 I I I I 1 I � --- _ --T- __T ___ --- __ T_ _ _ - -- T- -- r -- - I - -- t - -- + - -- I -- -+- CVS FIRE ALARM AND SECURITY VENDOR SHALL MODIFY, RELOCATE AND/OR CONSULTANT' I I I I I I I I I I I I PROVIDE ADDITIONAL CAMERAS, MOTION DETECTORS, SECURITY CAMERAS AND ---I- - -I- - --I-- - - - -- - - -- -I- - --�- - -I-- --- ---I - - - - - - - - -- ----- -- (D) 1�1f,�I I I I I (D) 1 I FIRE ALARM EQUIPMENT REQUIRED FOR COMPLETE AND OPERATIONAL SYSTEM BFtEAKR00M — —-1�1 HJT - - - -- T--- T--- - -- T -- - 1 � ---T - °� - - I -- -r - - -T -- FOR THE SCOPE OF WORK. COORDINATE WITH WALLS, CEILINGS, LIGHTS, 105 I I I __ _I__ _ _I I _ I __ I-- --Ig _I___ _I _ __I _ I I i __ DIFFUSERS, OBSTRUCTIONS, ETC. IN ALL AREAS AFFECTED BY THE SCOPE OF I 0 �--r gip)- i (D� i i (D)I I WORK. NEW EQUIPMENT SHALL BE COMPATIBLE WITH THE EXISTING SYSTEM. (D) -I- - -I- I- - - -I- - - - - - - -I- ---I- - - - - -- -- - -- -- (D)I I II i I I d- ° ' ® I I CHECKOUT T- - - -- -T --- T- -- - --T- - -T --, --- T- - -r- - - - - 1 102 1 1 I I I I I I I I I I I I I I I (D)! I 0 — - -r- --r--- r--- r —— — r — — —r -- - - --r - - - RECEIVING - -- -- - - - - -- - -- - - - - - -I -- - , 1 AREA I I I I I I I D I I (D) -�Y-; ---T- - -T -- - - - r ---T- -- - - -r - -- T- -- - - -- - 106A ® 1 D)'`' 1 SEAL: WORK RN AL PHOTO LAB SHADED 103 AREAoo oo ♦ �' ol r p� lo o 101 m W COL. �O 081 s I 1 REF. AA�FESS1�Nr� II (D) I I I 12/22/2022 (D) I I REVISIONS: 14Y-1 4 1 ! I 1 09-26-2022 OL Rx REVIEW#1 (15)' I 09-27-2022 OL Rx REVIEW#2 1 1 ® ® 09-27-2022 OL Rx REVIEW#3 D) I a--- a'--- ----a 10-03-2022 PL POST —14 1 Or 12-23-2022 BID/PERMIT SET ooD 1 I v Z d 1 I N0 ELECTRICAL WORK L SHAD \\ 11 1 ' ' AREA DRAWING(D) DRAWING BY: SGC \ 1 I`1 \ 1 1 I COL. CHECKED BY: EG 1 !(E) I REF. PI RMA Y \\ _ (R) 2 RETAIL I— R 2 ( ) MANAGER'S DATE: 09-22-2022 110 \ — — — — OFFICE \ 104 JOB NUMBER: 022139 1 1 1 1 O (D) (D) (D) TITLE: LIGHTING COL. REF. DEMOLITION PLAN I� '\RX WAITING SHEET NUMBER: 111 0 NEW YORK ALTERATION WARNING STATEMENT: ED1_ >- IT IS A VIOLATION OF THE NEW YORK EDUCATION LAW,ARTICLE 145,SECTION 0 1 OVERALL REMODEL LIGHTING DEMOLITION PLAN 7209 FOR ANY PERSON,UNLESS THE INDIVIDUAL IS ACTING UNDER THE COMMENTS: J DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE 0 ED1 SCALE: 1�8" = 1'—O° ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE j NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF 0 SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. GENERAL DEMOLITION NOTES 1. VISIT THE SITE TO VERIFY EXISTING CONDITIONS PRIOR TO SUBMISSION OF BID. NO ADDITIONAL COMPENSATION SHALL BE CONSIDERED FOR FAILURE TO OBSERVE THIS REQUIREMENT. 2. DISCONNECT AND REMOVE ALL ELECTRICAL WIRING AND EQUIPMENT AS TM REQUIRED WITHIN ALL AREAS TO BE RENOVATED. THIS SHALL INCLUDE BUT NOT BE LIMITED TO FIXTURES, DEVICES, OUTLETS, SWITCHES, RECEPTACLES, pharmacy STARTERS, DISCONNECTS, PANELS, FEEDERS, ETC. 3. WHERE ELECTRICAL ITEMS ARE REMOVED, ALL BRANCH DEVICE'S WIRING Reset + Rx Di ital Screen SHALL BE REMOVED BACK TO PANELBOARD SERVING THE EQUIPMENT. WHERE Expansion + Photo CIRCUITS SERVE ADDITIONAL DEVICES OR EQUIPMENT REMAINING, WIRING SHALL BE REMOVED BACK TO THE NEAREST ACTIVE JUNCTION BOX. STORE NUMBER 3105 4. MAINTAIN CONTINUITY OF EXISTING CIRCUITS THAT ARE TO REMAIN IN OPERATION AND SCHEDULE FOR REFEEDING FROM NEW PANELBOARDS. D RO MAIN A FORWARD FINDINGS TO ENGINEER FOR REVIEW AND COORDINATION. 9870 9870MATM IN A 11952 5. ALL UNUSED CIRCUITS REMAINING AFTER REMOVALS SHALL BECOME SPARE PROJECT TYPE: (72 & 182) IN PANELBOARDS, LABELED AS SPARE, AND SWITCHED TO THE OFF POSITION. 6. REFER TO ARCHITECTURAL DEMOLITION DRAWING FOR ADDITIONAL CS PROJECT NUMBER: 165265 INFORMATION AND SCOPE OF DEMOLITION. 7. ALL MATERIALS AND EQUIPMENT REMOVALS SHALL BE DISPOSED OF AS DIRECTED BY THE OWNER OR THE ARCHITECT. ARCHITECT OF RECORD: 8. ALL EMPTY CONDUITS MUST HAVE PULLWIRES AND BE TAGGED PROPERLY. 9. TIE BACK ALL LOOSE WIRING (INCLUDING LOW VOLTAGE). 10. VERIFY ALL EXISTING CIRCUITS AND RELABEL PANEL80ARD SCHEDULES IN < " FIELD AS REQUIRED. 1 129 E COL. COL. COL. COL. COL. 11. VERIFY ALL EXISTING PANELBOARD LOADING IN FIELD AS REQUIRED PRIOR REF. REF. REF. REF. REF. ANY NEW WORK. SBLM 545 West 45th Street 4th Floor 12. DISCONNECT AND REMOVE ALL EXISTING WALL RECEPTACLES HIGHER THAN New York, NY 1 Street 18 AFF IN RETAIL AREA EXCEPT EXISTING RECEPTACLES SERVING DIGITAL T; York, 1 0036 SCREENS, FREEZERS, COOLERS, CHECKOUT AND PHARMACY AREAS. www.sblm.com 13. RELOCATE ANY UNUSED POWER POLES FOR NEW LOCATIONS SHOWN ON NEW M N'S WORK PLAN. REMOVE ANY REMAINING POWER POLES NOT IN USE. TOILET HALL 07 14. REFER TO ELECTRICAL POWER PLAN FOR NEW AND RELOCATED FIXTURE CONSULTANT ENGINEER: 109 POWER LAYOUT. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR 0 ADDITIONAL INFORMATION. COL. 15. APPLIES TO ALL RELOCATED EQUIPMENT. UNLESS NOTED OTHERWISE: NO REF. I REMOVE EQUIPMENT AND SAVE WITH ANY SALVAGEABLE UTILITIES FOR CONSULTING J ELECTRICAL RELOCATION/REINSTALLATION. EXTEND/MODIFY EXISTING CIRCUITRY AND CONTROLS FOR ENGINEERS WORK IN NEW LOCATION AS REQUIRED AND RECONNECT. SHADED 240 WEST 37TH STREET,3RD FLOOR AREA VESTIBULE NEW YORK,NY 10018 o1z100 16. APPLIES TO ALL DEMOLISHED EQUIPMENT. UNLESS NOTED OTHERWISE: TEL 212.413.8400 REMOVE EQUIPMENT AND RETURN TO OWNER. REMOVE ANY CIRCUITRY AND www.hny-ong.com RELATED ACCESSORIES BACK TO THE SOURCE PANELBOARD OR NEAREST 2250003925 REMAINING DEVICE AND UPDATE CIRCUIT DIRECTORY ACCORDINGLY. O COORDINATE WITH FINAL MERCHANDISE PLAN FOR LOCATIONS OF EXISTING 1 POWER POLES THAT ARE TO BE RELOCATED. EXTEND AND RECONNECT GONDOLA WIRING CHASE CIRCUITING AND DEVICES. CONSULTANT: BREAKROOM zz [ 105 // I O --� (f=� /// // I i I CVS FIRE ALARM AND SECURITY VENDOR SHALL MODIFY, RELOCATE AND/OIR PROVIDE ADDITIONAL CAMERAS, MOTION DETECTORS, SECURITY CAMERAS AND / KXr-1I CHECKOUT FIRE ALARM EQUIPMENT REQUIRED FOR COMPLETE AND OPERATIONAL SYSTEM /,/ J 102 FOR THE SCOPE OF WORK. COORDINATE WITH WALLS, CEILINGS, LIGHTS, O i DIFFUSERS, OBSTRUCTIONS, ETC. IN ALL AREAS AFFECTED BY THE SCOPE OF J i� 3 I ; i I WORK. NEW EQUIPMENT SHALL BE COMPATIBLE WITH THE EXISTING SYSTEM. RECEIVING AREA I �'�/ I I D [106A - -- -- - - - - --- -- - - - -- - ---- - _ --- I i L J 4CF ELECTRICAL LEGEND NOTES 71 00, NO I ° O ELECTRICAL FIXTURES AND EQUIPMENT IN THIS AREA TO BE SEAL ° REVISED/RELOCATED/REPLACED. REMOVE EXISTING WIRING DEVICES, r.- WORK RN AL I ° PHOTO LAB EXPOSED RACEWAY, CIRCUITRY AND RELATED ACCESSORIES NOT BEINGpF Mew SHADED I -' __- 103 REUSED BACK TO SOURCE PANELBOARD OR NEAREST REMAINING DEVICE AREA ° AND UPDATE CIRCUIT DIRECTORY ACCORDINGLY. MAINTAIN EXISTING '� •��� �O '�' ° ELECTRICAL INSTALLATIONS TO SERVE REMAINING EQUIPMENT AND THAT RETAIL ❑ -- USED FOR TEMPORARY PURPOSES. r.. 101 I °� 2 MONEYGRAM MACHINE TO BE RELOCATED. �^ w ° �� O - COL. REF. O3 EXTRACARE COUPON CENTER KIOSK (ECC) TO BE RELOCATED. a �gtn's L �- -� R�FES51ONr - — J O4 DUPLEX PRINTER TO BE RELOCATED. 1 O POSTER PRINTER TO BE RELOCATED. 12/22/2022 O6 ATM TO BE RELOCATED. REVISIONS: g O BLOOD PRESSURE MACHINE TO BE RELOCATED. 09-26-2022 OL RX REVIEW#1 V10x��,; I Og 10 DEMOLISH EXISTING POWER POLES. REMOVE CIRCUITING BACK TO NEAREST 09'27-2022 OL RX REVIEW#2 5 JUNCTION BOX. PROTECT CIRCUIT DURING DEMOLITION. CIRCUITS TO BE 09-27-2022 OL RX REVIEW#3 r-� EXTENDED TO NEW POWER POLES IN NEW CONSTRUCTION. UPDATE OO I i i CIRCUIT DIRECTORY IN PANELBOARDS ACCORDINGLY. 10-03-2022 PL POST I L_J 12-23-2022 BID/PERMIT SET I 35O i F NO WRN AL WORK SHA AREAED z 10 \\\ I DRAWING BY: SGC \1--- -- - - -- - - - - - -- - - -- - - -- - --- - -- -- - -- - - -- - --- --- --- -� RETAIL ROF. CHECKED BY: EG P RMA Y \�\\ 101 oOO MANAGER'S 110 \\ 8 OFFICE DATE: 09-22-2022 JOB NUMBER: 022139 TITLE: Jill, COL. POWER REF. O 7WAITING DEMOLITION PLAN 111 SHEET NUMBER: NEW YORK ALTERATION WARNING STATEMENT: ED2_ IT IS AVIOLATION OF THE NEW EDUCATION LAW,ARTICLE 145„SECTION OVERALL REMODEL POWER DEMOLITION PLAN COMMENTS: J 7209 FOR ANY PERSON,UNLESS THE INDIVIDUAL IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AN ITEM IN ED2 SCALE: 1/8" = 1'-0" ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE 0 ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THIE oNOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. SECTION 23 0130.51 HVAC AIR DUCT CLEANING 3.03 PREPARATION C. METAL CHANNEL (STRUT) FRAMING SYSTEMS: FACTORY-FABRICATED CONTINUOUS-SLOT C. PROVIDE INDEPENDENT SUPPORT FROM BUILDING STRUCTURE. DO NOT PROVIDE SUPPORT 1. SMACNA (TAB). PART 1 GENERAL A. WHEN CLEANING WORK MIGHT ADVERSELY AFFECT LIFE SAFETY SYSTEMS, INCLUDING FIRE AND METAL CHANNEL STRUT AND ASSOCIATED FITTINGS, ACCESSORIES, AND HARDWARE REQUIRED FROM PIPING, DUCTWORK, CONDUIT, OR OTHER SYSTEMS. (STRUT) B. BEGIN WORK AFTER COMPLETION OF SYSTEMS TO BE TESTED, ADJUSTED, OR BALANCED AND 1.01 SECTION INCLUDES SMOKE DETECTION, ALARM, AND CONTROL, COORDINATE SCHEDULING AND TESTING AND FOR FIELD-ASSEMBLY OF SUPPORTS. D. UNLESS SPECIFICALLY INDICATED OR APPROVED BY ARCHITECT, DO NOT PROVIDE SUPPORT COMPLETE WORK PRIOR TO SUBSTANTIAL COMPLETION OF THE PROJECT. A. CLEANING OF HVAC DUCT SYSTEM, EQUIPMENT, AND RELATED COMPONENTS. INSPECTION PROCEDURES WITH AUTHORITIES HAVING JURISDICTION. 1. MANUFACTURERS: FROM SUSPENDED CEILING SUPPORT SYSTEM OR CEILING GRID. C. TAB AGENCY QUALIFICATIONS: :' B. TESTING AND INSPECTION AGENCY EMPLOYED BY OWNER. B. ENSURE THAT ELECTRICAL COMPONENTS THAT MIGHT BE ADVERSELY AFFECTED BY CLEANING 1.1. COOPER B-LINE, A DIVISION OF EATON CORPORATION: E. UNLESS SPECIFICALLY INDICATED OR APPROVED BY ARCHITECT, DO NOT PROVIDE SUPPORT 1. COMPANY SPECIALIZIN ARE DE-ENERGIZED LOCKED OUT, AND PROTECTED PRIOR TO BEGINNING WORK. WWW.000PERINDUSTRIES.COM/#SLE. FROM ROOF DECK. GIN THE TESTING, ADJUSTING, AND BALANCING OF SYSTEMS 1.02 RELATED REQUIREMENTS SPECIFIED IN THIS SECTION. v ':` ­ "7: A. SECTION 01 4000 - QUALITY REQUIREMENTS: ADDITIONAL REQUIREMENTS FOR TESTING AND C. AIR-VOLUME CONTROL DEVICES: MARK THE ORIGINAL POSITION OF DAMPERS AND OTHER 1.2. THOMAS & BETTS CORPORATION: WWW.TNB.COM/#SLE. F. DO NOT PENETRATE OR OTHERWISE NOTCH OR CUT STRUCTURAL MEMBERS WITHOUT 2. HAVING MINIMUM OF THREE YEARS DOCUMENTED EXPERIENCE. AIR-DIRECTIONAL MECHANICAL DEVICES INSIDE THE HVAC SYSTEM PRIOR TO STARTING , APPROVAL OF STRUCTURAL ENGINEER. INSPECTION AGENCIES. 1.3. UNISTRUT, A BRAND OF ATKORE INTERNATIONAL INC: NWW.UNISTRUT.COM/#SLE. 3. CERTIFIED BY ONE OF THE FOLLOWING: CLEANING. G. FIELD-WELDING (WHERE APPROVED BY ARCHITECT): COMPLY WITH SECTION 05 5000. F-wmat%vr' B. SECTION 01 5719 - TEMPORARY ENVIRONMENTAL CONTROLS. D. ACCESS TO CONCEALED SPACES: USE EXISTING SERVICE OPENINGS AND MAKE ADDITIONAL 1.4. APPROVED EQUAL. 3.1. AABC, ASSOCIATED AIR BALANCE COUNCIL: WWW.AABC.COM; UPON COMPLETION kjhav %Ify C. SECTION 01 9113 - GENERAL COMMISSIONING REQUIREMENTS: COMMISSIONING REQUIREMENTS SERVICE OPENINGS AS REQUIRED TO ACCOMPLISH CLEANING AND INSPECTION. 1.5. SUBSTITUTIONS: SEE SECTION 01 6000 - PRODUCT REQUIREMENTS. H. PROVIDE THERMAL INSULATED PIPE SUPPORTS COMPLETE WITH HANGERS AND ACCESSORIES. SUBMIT AABC NATIONAL PERFORMANCE GUARANTY. Vir THAT APPLY TO ALL TYPES OF WORK. INSTALL THERMAL INSULATED PIPE SUPPORTS DURING THE INSTALLATION OF THE PIPING 3.2. NEBB, NATIONAL ENVIRONMENTAL BALANCING BUREAU: WWW.NEBB.ORG. 1. DO NOT CUT OPENINGS IN NON-HVAC COMPONENTS WITHOUT OBTAINING THE PRIOR 1.6. SOURCE LIMITATIONS: FURNISH CHANNELS (STRUTS) AND ASSOCIATED FITTINGS, SYSTEM. gialoScreen D. SECTION 23 0800 - COMMISSIONING OF HVAC. APPROVAL OF OWNER. ACCESSORIES, AND HARDWARE PRODUCED BY A SINGLE MANUFACTURER. 3.3. TABB, THE TESTING, ADJUSTING, AND BALANCING BUREAU OF NATIONAL ENERGY Reset + Rx D 1.03 PRICE AND PAYMENT PROCEDURES 2. MAKE NEW OPENINGS IN HVAC COMPONENTS IN ACCORDANCE WITH NADCA STANDARD 05; 2. PROVIDE FACTORY-FABRICATED CONTINUOUS-SLOT METAL CHANNEL (STRUT) AND I• EQUIPMENT SUPPORT AND ATTACHMENT: MANAGEMENT INSTITUTE: WWW.TABBCERTIFIED.ORG.A. SEE SECTION 01 2100 - ALLOWANCES, FOR CASH, TESTING, AND QUANTITY ALLOWANCES DO NOT COMPROMISE THE STRUCTURAL INTEGRITY OF THE SYSTEM. ASSOCIATED FITTINGS, ACCESSORIES, AND HARDWARE REQUIRED FOR FIELD-ASSEMBLY OF 1. USE METAL FABRICATED SUPPORTS OR SUPPORTS ASSEMBLED FROM METAL CHANNEL D. TAB SUPERVISOR AND TECHNICIAN QUALIFICATIONS: CERTIFIED BY SAME ORGANIZATION AS EXpanSon + ot AFFECTING THIS SECTION. 3. DO NOT CUT SERVICE OPENINGS INTO FLEXIBLE DUCT; DISCONNECT AT ENDS FOR SUPPORTS. (STRUT) TO SUPPORT EQUIPMENT AS REQUIRED. TAB AGENCY. B. SEE SECTION 01 2200 - UNIT PRICES, FOR ADDITIONAL UNIT PRICE REQUIREMENTS. CLEANING AND INSPECTION. 3. COMPLY WITH MFMA-4. 2. USE METAL CHANNEL (STRUT) SECURED TO STUDS TO SUPPORT EQUIPMENT 3.02 EXAMINATION STORE NUMBER 3105 SURFACE-MOUNTED ON HOLLOW STUD WALLS WHEN WALL STRENGTH IS NOT SUFFICIENT TO A. VERIFY THAT SYSTEMS ARE COMPLETE AND OPERABLE BEFORE COMMENCING WORK. ENSURE 1.04 DEFINITIONS E. CEILING TILE: LAY-IN CEILING TILE MAY BE REMOVED TO GAIN ACCESS TO HVAC SYSTEMS 4. CHANNEL MATERIAL: RESIST PULL-OUT. THE FOLLOWING CONDITIONS: 9870 MAIN ROAD A. HVAC SYSTEM: FOR PURPOSES OF THIS SECTION, THE SURFACES TO BE CLEANED INCLUDE DURING THE CLEANING PROCESS; PROTECT TILE FROM DAMAGE AND REINSTALL UPON 4.1. INDOOR DRY LOCATIONS: USE PAINTED STEEL, ZINC-PLATED STEEL, OR GALVANIZED 3. USE METAL CHANNEL STRUT TO SUPPORT SURFACE-MOUNTED EQUIPMENT IN WET OR 1. SYSTEMS ARE STARTED AND OPERATING IN A SAFE AND NORMAL CONDITION. MATTITUCK, NY 11952 ALL INTERIOR SURFACES OF THE HEATING, AIR-CONDITIONING AND VENTILATION SYSTEM FROM COMPLETION; REPLACE DAMAGED TILE. STEEL. (STRUT) THE POINTS WHERE THE AIR ENTERS THE SYSTEM TO THE POINTS WHERE THE AIR IS 3.04 CLEANING 4.2. OUTDOOR AND DAMP OR WET INDOOR LOCATIONS: USE GALVANIZED STEEL. DAMP LOCATIONS TO PROVIDE SPACE BETWEEN EQUIPMENT AND MOUNTING SURFACE, 2. TEMPERATURE CONTROL SYSTEMS ARE INSTALLED COMPLETE AND OPERABLE. 4. UNLESS OTHERWISE INDICATED, MOUNT FLOOR-MOUNTED EQUIPMENT ON PROPERLY SIZED 6 3PROPER THERMAL OVERLOAD PROTECTION IS IN PLACE FOR ELECTRICAL EQUIPMENTPROJECT TYPE: (72 & 182) DISCHARGED FROM THE SYSTEM, INCLUDING THE INSIDE OF AIR DISTRIBUTION EQUIPMENT, A. USE ANY CLEANING METHOD RECOMMENDED BY NADCA ACR UNLESS OTHERWISE SPECIFIED; 5. MINIMUM CHANNEL THICKNESS: STEEL SHEET, 12 GAGE, 0.1046 INCH (2.66 MM). . .INCH (150 MM) HIGH CONCRETE PAD CONSTRUCTED IN ACCORDANCE WITH SECTION 03 COILS, AND CONDENSATE DRAIN PANS; SEE NADCA ACR FOR MORE DETAILS. DO NOT USE METHODS PROHIBITED BY NADCA ACR, OR THAT WILL DAMAGE HVAC 6• MINIMUM CHANNEL DIMENSIONS: 1-5/8 INCH (41 MM) WIDTH BY 13/16 INCH (21 MM) 3000. 4. FINAL FILTERS ARE CLEAN AND IN PLACE. IF REQUIRED, INSTALL TEMPORARY MEDIA IN 1. ABOVE-CEILING PLENUM FOR SUPPLY AIR IS REQUIRED TO BE CLEANED. COMPONENTS OR OTHER WORK, OR THAT WILL SIGNIFICANTLY ALTER THE INTEGRITY OF THE HEIGHT. ADDITION TO FINAL FILTERS. l�,p� 2. ABOVE-CEILING PLENUM FOR RETURN AIR IS REQUIRED TO BE CLEANED. SYSTEM. 5. SECURELY FASTEN FLOOR-MOUNTED EQUIPMENT. DO NOT INSTALL EQUIPMENT SUCH THAT 5. DUCT SYSTEMS ARE CLEAN OF DEBRIS. ����++CS PROJECT NUMER: 165265 3. MAKEUP AIR SYSTEM IS REQUIRED TO BE CLEANED. B. OBTAIN OWNER'S APPROVAL BEFORE USING WET CLEANING METHODS; ENSURE THAT DRAINAGE D. HANGER RODS: THREADED ZINC-PLATED STEEL UNLESS OTHERWISE INDICATED. IT RELIES ON ITS OWN WEIGHT FOR SUPPORT. 6. FANS ARE ROTATING CORRECTLY. E 1. MINIMUM SIZE, UNLESS OTHERWISE INDICATED OR REQUIRED: J. PRESET CONCRETE INSERTS: USE MANUFACTURER PROVIDED CLOSURE STRIPS TO INHIBIT 4. EXHAUST-ONLY SYSTEM IS REQUIRED TO BE CLEANED. IS ADEQUATE BEFORE BEGINNING. 7. FIRE AND VOLUME DAMPERS ARE IN PLACE AND OPEN. DURING CONCRETE POUR . CONCRETE SEEPAGE . 1.05 REFERENCE STANDARDS C. DUCTS: MECHANICALLY CLEAN ALL PORTIONS OF DUCTS. 1.1. EQUIPMENT SUPPORTS: 1/2 INCH (13 MM) DIAMETER8. AIR COIL FINS ARE CLEANED AND COMBED. ARCHITECT OF RECORD' 1.2. PIPING UP TO 1 INCH (27 MM) NOMINAL: 1/4 INCH (6 MM) DIAMETER. K. SECURE FASTENERS ACCORDING TO MANUFACTURER'S RECOMMENDED TORQUE SETTINGS. A. ASTM E84 - STANDARD TEST METHOD FOR SURFACE BURNING CHARACTERISTICS OF BUILDING D. HOSES, CABLES, AND EXTENSION RODS: CLEAN USING SUITABLE SANITARY DAMP WIPES AT 1.3. PIPING LARGER THAN 1 INCH 27 MM NOMINAL: 3 8 9. ACCESS DOORS ARE CLOSED AND DUCT END CAPS ARE IN PLACE. MATERIALS; 2017. THE TIME THEY ARE BEING REMOVED OR WITHDRAWN FROM THEIR NORMAL POSITION, ( ) / INCH (10 MM) DIAMETER. L. REMOVE TEMPORARY SUPPORTS. 10.AIR OUTLETS ARE INSTALLED AND CONNECTED. B. NADCA ACR - ASSESSMENT, CLEANING AND RESTORATION OF HVAC SYSTEMS; 2013. E. REGISTERS, DIFFUSERS, AND GRILLES: WHEN REMOVING, TAKE CARE TO PREVENT 1.4. TRAPEZE SUPPORT FOR MULTIPLE PIPES: 3/8 INCH (10 MM) DIAMETER. 2.03 FIELD QUALITY CONTROL 11. DUCT SYSTEM LEAKAGE IS MINIMIZED. C. UL 181 - STANDARD FOR FACTORY-MADE AIR DUCTS AND AIR CONNECTORS; CURRENT CONTAINMENT EXPOSURE DUE TO ACCUMULATED DEBRIS. 1.5. THERMAL INSULATED PIPE SUPPORTS: A. SEE SECTION 01 4000 - QUALITY REQUIREMENTS, FOR ADDITIONAL REQUIREMENTS. B. SUBMIT FIELD REPORTS. REPORT DEFECTS AND DEFICIENCIES THAT WILL OR COULD PREVENT 3 f. , EDITION, INCLUDING ALL REVISIONS. F. COILS: FOLLOW NADCA ACR COMPLETELY INCLUDING MEASURING STATIC PRESSURE DROP 1. MANUFACTURERS: B. INSPECT SUPPORT AND ATTACHMENT COMPONENTS FOR DAMAGE AND DEFECTS. PROPER SYSTEM BALANCE. BEFORE AND AFTER CLEANING; DO NOT REMOVE REFRIGERATION COILS FROM SYSTEM TO 1.1. KB ENTERPRISES: WWW.SNAPPITZ.COM/#SLE. C. REPAIR CUTS AND ABRASIONS IN GALVANIZED FINISHES USING ZINC-RICH PAINT C. BEGINNING OF WORK MEANS ACCEPTANCE OF EXISTING CONDITIONS. D. UL 181A - CLOSURE SYSTEMS FOR USE WITH RIGID AIR DUCTS; CURRENT EDITION, INCLUDING .._' ALL REVISIONS. CLEAN; REPORT COILS THAT ARE PERMANENTLY IMPACTED. 1.2. APPROVED EQUAL. RECOMMENDED BY MANUFACTURER. REPLACE COMPONENTS THAT EXHIBIT SIGNS OF 3.03 PREPARATION 1.06 SUBMITTALS G. FIBROUS GLASS MATERIAL: USE HEPA VACUUMING EQUIPMENT, UNDER CONSTANT NEGATIVE 2. GENERAL CONSTRUCTION AND REQUIREMENTS: CORROSION. A. PROVIDE INSTRUMENTS REQUIRED FOR TESTING, ADJUSTING, AND BALANCING OPERATIONS. A. SEE SECTION 01 3000 - ADMINISTRATIVE REQUIREMENTS, FOR SUBMITTAL PROCEDURES. PRESSURE, DO NOT PERMIT TO GET WET, AND DO NOT DAMAGE SURFACES; REPLACE 2.1. INSULATED PIPE SUPPORTS TO BE PROVIDED AT HANGER, SUPPORT, AND GUIDE D. CORRECT DEFICIENCIES AND REPLACE DAMAGED OR DEFECTIVE SUPPORT AND ATTACHMENT MAKE INSTRUMENTS AVAILABLE TO ARCHITECT TO FACILITATE SPOT CHECKS DURING TESTING. SBLM B. PRODUCT DATA: MANUFACTURER'S DATA SHEETS ON EACH PRODUCT TO BE USED. MATERIAL DAMAGED BY CLEANING OPERATIONS. LOCATIONS ON PIPE REQUIRING INSULATION OR ADDITIONAL SUPPORT. COMPONENTS. B. PROVIDE ADDITIONAL BALANCING DEVICES AS REQUIRED. 545 West 45th Street 4th Floor H. EXISTING DAMAGED FIBROUS GLASS MATERIAL: REPORT TO ARCHITECT ALL EVIDENCE OF E. HANGER ADJUSTMENT: ADJUST HANGERS TO DISTRIBUTE LOADS EQUALLY C. QUALIFICATIONS STATEMENT: SUBMIT QUALIFICATIONS OF PROPOSED CLEANING CONTRACTOR 2.2. SURFACE BURNING CHARACTERISTICS: FLAME SPREAD INDEX/SMOKE DEVELOPED 3.04 ADJUSTMENT TOLERANCES DAMAGE DETERIORATION DELAMINATING FRIABLE MATERIAL MOLD OR FUNGUS GROWTH OR ON ATTACHMENTS AND TO ACHIEVE INDICATED SLOPE OF PIPE. New York, NY 10036 FOR APPROVAL. MOISTURE THAT CANNOT BE REMEDIED BY CLEANING OR RESURFACING WITH AN ACCEPTABLE INDEX OF 5/30, MAXIMUM, WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723• A. AIR HANDLING SYSTEMS: ADJUST TO WITHIN PLUS OR MINUS 5 PERCENT OF DESIGN FOR D. QUALIFICATIONS STATEMENT: SUBMIT QUALIFICATIONS OF PROPOSED TESTING AND INSPECTION INSULATION REPAIR COATING. SUPPLY SYSTEMS AND PLUS OR MINUS 10 PERCENT OF DESIGN FOR RETURN AND EXHAUST T: 212.995.5600 AGENCY FOR APPROVAL. 1. MATERIAL WITH ACTIVE FUNGAL GROWTH IS CONSIDERED UNREMEDIABLE. 2.3. PIPE SUPPORTS TO BE PROVIDED FOR NOMINALLY SIZEC, 1/2 INCH TO 30 INCH (12.7 SECTION 23 0553 SYSTEMS. www.sblm.com E. PROJECT CLEANLINESS EVALUATION AND CLEANING PLAN, AS SPECIFIED. 2. REMOVE UNREMEDIABLE MATERIAL AND CLEAN UNDERLYING SURFACES. MM TO 762 MM) IRON PIPES. IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT B. AIR OUTLETS AND INLETS: ADJUST TOTAL TO WITHIN PLUS 10 PERCENT AND MINUS 5 F. MATERIAL SAFETY DATA SHEETS (MSDS): FOR ALL CHEMICAL PRODUCTS PROPOSED TO BE 3. WHERE SURFACE DAMAGE CAN BE REPAIRED BY APPLYING A COATING, DO SO AT NO 2.4. INSULA11ON INSERTS TO CONSIST OF POLIISOCYANURATE (URETHANE) INSULATION PART 1 GENERAL PERCENT OF DESIGN TO SPACE. ADJUST OUTLETS AND INLETS IN SPACE TO WITHIN PLUS OR USED IN THE CLEANING PROCESS; SUBMIT DIRECTLY TO OWNER. EXTRA COST TO OWNER. SURROUNDED BY A 360 DEGREE, PVC JACKETING. 1.01 SECTION INCLUDES MINUS 10 PERCENT OF DESIGN. CONSULTANT ENGINEER' G. PROJECT CLOSEOUT REPORT: INCLUDE FIELD QUALITY CONTROL REPORTS, EVIDENCE OF 4. REPLACE UNREMEDIABLE MATERIAL AT NO EXTRA COST TO OWNER. 3. PVC JACKET: A. ADHESIVE-BACKED DUCT MARKERS. 3.05 RECORDING AND ADJUSTING SATISFACTORY CLEANING, AND DOCUMENTATION OF ITEMS NEEDING FURTHER REPAIR. 5. REPLACE UNREMEDIABLE MATERIAL. 3.1. PIPE INSULATION PROTECTION SHIELDS TO BE PROVIDED WITH A BALL BEARING HINGE 1.02 REFERENCE STANDARDS A. FIELD LOGS: MAINTAIN WRITTEN LOGS INCLUDING: 1.07 QUALITY ASSURANCE 6. REPLACEMENT OF UNREMEDIABLE MATERIAL IS NOT COVERED BY THIS SPECIFICATION. AND LOCKING SEAM. A. ASTM D709 - STANDARD SPECIFICATION FOR LAMINATED THERMOSETTING MATERIALS; 2017. 1. RUNNING LOG OF EVENTS AND ISSUES. A. INFORMATION AVAILABLE TO CONTRACTOR: NO EXISTING SYSTEM DOCUMENTATION IS AVAILABLE. I. COLLECT DEBRIS REMOVED DURING CLEANING; ENSURE THAT DEBRIS IS NOT DISPERSED 3.2. MINIMUM SERVICE TEMPERATURE: MINUS 40 DEGREES F (MINUS 40 DEGREES C). PART 2 PRODUCTS 2. DISCREPANCIES, DEFICIENT OR UNCOMPLETED WORK BY OTHERS. mm B. INFORMATION AVAILABLE TO CONTRACTOR: UPON REQUEST, OWNER WILL PROVIDE THE OUTSIDE THE HVAC SYSTEM DURING THE CLEANING PROCESS. 3.3. MAXIMUM SERVICE TEMPERATURE: 180 DEGREES F (82 DEGREES C). 2.01 ADHESIVE-BACKED DUCT MARKERS 3. CONTRACT INTERPRETATION REQUESTS. CONSULTING FOLLOWING: J. STORE CONTAMINATED TOOLS AND EQUIPMENT IN POLYETHYLENE BAGS UNTIL CLEANED IN THE 3.4. MOISTURE VAPOR TRANSMISSION: 0.0071 PERM INCH (0.0092 NG/PA S M), WHEN A. MANUFACTURERS: 4. LISTS OF COMPLETED TESTS. ENGINEERS 1. ONE COPY OF ORIGINAL CONSTRUCTION DRAWINGS OF HVAC SYSTEM. DESIGNATED DECONTAMINATION AREA. TESTED IN ACCORDANCE WITH ASTM E96/E96M. 1. BRIMAR INDUSTRIES, INC: WWW.PIPEMARKER,COM/#SLE. B. ENSURE RECORDED DATA REPRESENTS ACTUAL MEASURED OR OBSERVED CONDITIONS. 240 WEST 37TH STREET,3RD FLOOR C. PERMANENTLY MARK SETTINGS OF VALVES, DAMPERS, AND OTHER ADJUSTMENT DEVICES NEWYORK,NY 10018 2. ONE COPY OF ORIGINAL CONSTRUCTION SPECIFICATIONS OF HVAC SYSTEM. 3.05 REPAIR 3.5. THICKNESS: 60 MIL (1.524 MM). B. MATERIAL: HIGH GLOSS ACRYLIC ADHESIVE-BACKED VINYL FILM 0.0032 INCH (0.76 MM); TEL 212.413.8400 3. CLEANLINESS INSPECTION REPORT PERFORMED BY SEPARATE CONTRACTOR. A. REPAIR OPENINGS CUT IN THE VENTILATION SYSTEM SO THAT THEY DO NOT SIGNIFICANTLY 3.6. CONNECTIONS: BRUSH ON WELDING ADHESIVE. PRINTED WITH UV AND CHEMICAL RESISTANT INKS. ALLOWING SETTINGS TO BE RESTORED. SET AND LOCK MEMORY STOPS. www.hny-eng.com 4. INDOOR AIR QUALITY REPORT PERFORMED BY SEPARATE CONTRACTOR. ALTER THE AIRFLOW OR ADVERSELY IMPACT THE FACILITY'S INDOOR AIR QUALITY. 4. PIPE INSULATION PROTECTION SHIELDS TO BE PROVIDED AT THE HANGER POINTS AND C. STYLE: INDIVIDUAL LABEL. D. AFTER ADJUSTMENT, TAKE MEASUREMENTS TO VERIFY BALANCE HAS NOT BEEN DISRUPTED OR 2250003925 5. HAZARDOUS MATERIAL REPORT PERFORNED BY SEPARATE CONTRACTOR. B. AT INSULATED DUCTS AND COMPONENTS, ACCOMPLISH REPAIRS IN SUCH A MANNER AS TO GUIDE LOCATIONS ON PIPES REQUIRING INSULA11ON AS INDICATED ON DRAWINGS. THAT SUCH DISRUPTION HAS BEEN RECTIFIED. D. COLOR: YELLOW BACKGROUND/BLACK LETTERING. E. LEAVE SYSTEMS IN PROPER WORKING ORDER, REPLACING BELT GUARDS, CLOSING ACCESS C. CLEANING CONTRACTOR QUALIFICATIONS: COMPANY SPECIALIZING IN THE CLEANING AND ACHIEVE THE EQUIVALENT THERMAL VALUE. E. NON-PENETRATING ROOFTOP SUPPORTS FOR LOW-SLOPE ROOFS: 2.02 CEILING TACKS DOORS, CLOSING DOORS TO ELECTRICAL SWITCH BOXES, AND RESTORING THERMOSTATS TO RESTORATION OF HVAC SYSTEMS AS SPECIFIED IN THIS SECTION. C. RESEAL NEW OPENINGS IN ACCORDANCE WITH NADCA STANDARD 05. 1. MANUFACTURERS: A. MANUFACTURERS: SPECIFIED SETTINGS. 1. CERTIFIED BY ONE OF THE FOLLOWING: D. RESEAL RIGID FIBER GLASS DUCT SYSTEMS USING CLOSURE TECHNIQUES THAT COMPLY WITH 1.1• COOPER B-LINE, A DIVISION OF EATON CORPORATION: 1. CRAFTMARK: WWW.CRAFTMARKID.COM. F. CUT INSULATION AROUND DUCTWORK AND PIPING FOR INSTALLATION OF TEST PROBES TO THE A. NADCA, NATIONAL AIR DUCT CLEANERS ASSOCIATION: WWW.NADCA.COM UL 181 OR UL 181A. WWW.000PERINDUSTRIES.COM/#SLE. CONSULTANT B. NATIONALLY RECOGNIZED CERTIFICATION PROGRAM AND ORGANIZATION DEDICATED TO E. WHEN NEW OPENINGS ARE INTENDED TO BE CAPABLE OF BEING RE-OPENED IN THE FUTURE, B. DESCRIPTION: STEEL WITH 3/4 INCH (20 MM) DIAMETER COLOR CODED HEAD. MINIMUM EXTENT NECESSARY TO ALLOW ADEQUATE PERFORMANCE OF PROCEDURES. ' THE CLEANING OF HVAC SYSTEMS. CLEARLY MARK THEM AND REPORT THEIR LOCATIONS TO OWNER IN PROJECT REPORT 1.2. ERICO INTERNATIONAL CORPORATION, A BRAND OF PENTAIR: WWW.ERICO.COM/#SLE. C. COLOR CODE AS FOLLOWS: G. PATCH AND SEAL INSULATION, VAPOR BARRIER, DUCTWORK, AND HOUSING, USING MATERIALS . 2. HAVING MINIMUM O THREE YEARS DOCUMENTED EXPERIENCE. 1.3. PHP SYSTEMS/DESIGN: WWW.PHPSD.COM/#SLE. IDENTICAL TO THOSE REMOVED. F DOCUMENTS. 1. HVAC EQUIPMENT: YELLOW 3. EMPLOYING FOR THIS PROJECT A SUPERVISOR CERTIFIED AS AN AIR SYSTEMS CLEANING 3.06 FIELD QUALITY CONTROL 1.4. UNISTRUT, A BRAND OF ATKORE INTERNATIONAL INC: WWW.UNISTRUT.COM/#SLE. PART 3 EXECUTION H. SEAL DUCT AND PIPING AND TEST AND REPAIR LEAKS. APPROVED EQUAL.. SPECIALIST BY NADCA. A. ENSURE THAT THE FOLLOWING FIELD QUALITY CONTROL ACTIVITIES ARE COMPLETED PRIOR TO 1. 3.01 PREPARATION 3.06 AIR SYSTEM PROCEDURE - 4. EMPLOYING FOR THIS PROJECT A SUPERVISOR CERTIFIED BY SAME ORGANIZATION THAT APPLICATION OF ANY TREATMENTS OR COATINGS AND PRIOR TO RETURNING HVAC SYSTEM TO 2. PROVIDE STEEL PEDESTALS WITH THERMOPLASTIC OR RUBBER BASE THAT REST ON TOP OF A. ADJUST AIR HANDLING AND DISTRIBUTION SYSTEMS TO PROVIDE REQUIRED OR DESIGN SUPPLY, CERTIFIED THE CLEANING CONTRACTOR. NORMAL OPERATION. 3.022 INSTALLATION ROOFING MEMBRANE, NOT REQUIRING ANY ATTACHMENT TO THE ROOF STRUCTURE AND NOT PENETRATING THE ROOFING ASSEMBLY, WITH SUPPORT FIXTURES AS SPECIFIED. DEGREASE AND CLEAN SURFACES TO RECEIVE ADHESIVE FOR IDENTIFICATION MATERIALS. RETURN, AND EXHAUST AIR QUANTITIES AT SITE ALTITUDE. 5. ACCEPTABLE CLEANING CONTRACTORS: B. EMPLOY AN INDEPENDENT TESTING AND INSPECTION AGENCY TO INSPECT, TEST, AND PREPARE B. MAKE AIR QUANTITY MEASUREMENTS IN DUCTS BY PITOT TUBE TRAVERSE OF ENTIRE CROSS 3. BASE SIZES: AS REQUIRED TO DISTRIBUTE LOAD SUFFICIENTLY TO PREVENT INDENTATION A. INSTALL NAMEPLATES WITH CORROSIVE-RESISTANT MECHANICAL FASTENERS, OR ADHESIVE. SECTIONAL AREA OF DUCT. A. --i---• DOCUMENTATION. APPLY WITH SUFFICIENT ADHESIVE TO ENSURE PERMANENT ADHESION AND SEAL WITH CLEAR C. VISUALLY INSPECT ALL PORTIONS OF THE CLEANED COMPONENTS; IF NOT VISIBLY CLEAN AS OF ROOFING ASSEMBLY. C. MEASURE AIR QUANTITIES AT AIR INLETS AND OUTLETS. B. SUBSTITUTIONS: SEE SECTION 01 6000 - PRODUCT REQUIREMENTS. 4. ATTACHMENT/SUPPORT FIXTURES: AS RECOMMENDED BY MANUFACTURER, SAME TYPE AS LACQUER. C. TESTING AND INSPECTION AGENCY QUALIFICATIONS: EXPERIENCED IN INSPECTION DEFINED IN NADCA ACR, RE-CLEAN AND REINSPECT. B. INSTALL DUCTWORK WITH PLASTIC NAMEPLATES. IDENTIFY WITH AIR HANDLING UNIT D. ADJUST DISTRIBUTION SYSTEM TO OBTAIN UNIFORM SPACE TEMPERATURES FREE FROM AND TESTING USING METHODS DEFINED IN NADCA ACR. D. COILS: CLEANING MUST RESTORE THE COIL PRESSURE DROP TO WITHIN 10 PERCENT OF THE INDICATED FOR EQUIVALENT INDOOR HANGERS AND SUPPORTS. IDENTIFICATION NUMBER AND AREA SERVED. LOCATE IDENTIFICATION AT AIR HANDLING UNIT, OBJECTIONABLE DRAFTS AND NOISE• 6. SEE SECTION 01 4000 FOR ADDITIONAL REQUIREMENTS. COILS ORIGINAL INSTALLED PRESSURE DROP; IF ORIGINAL PRESSURE DROP IS NOT KNOWN, 5. MOUNTING HEIGHT: PROVIDE MINIMUM CLEARANCE OF 6 INCHES (150 MM) UNDER AT EACH SIDE OF PENETRATION OF STRUCTURE OR ENCLOSURE, AND AT EACH OBSTRUCTION. E. USE VOLUME CONTROL DEVICES TO REGULATE AIR QUANTITIES ONLY TO EXTEND THAT PART 2 PRODUCTS COIL WILL BE CONSIDERED CLEAN IF FREE OF FOREIGN MATTER AND CHEMICAL RESIDUE SUPPORTED COMPONENT TO TOP OF ROOFING. C. LOCATE CEILING TACKS TO LOCATE VALVES OR DAMPERS ABOVE LAY-IN PANEL CEILINGS. ADJUSTMENTS DO NOT CREATE OBJECTIONABLE AIR MOTION OR SOUND LEVELS. EFFECT 2.01 TOOLS AND EQUIPMENT BASED ON VISUAL INSPECTION. F. ANCHORS AND FASTENERS: LOCATE IN CORNER OF PANEL CLOSEST TO EQUIPMENT. VOLUME CONTROL BY DUCT INTERNAL DEVICES SUCH AS DAMPERS AND SPLITTERS. SEAL' A. VACUUM DEVICES AND OTHER TOOLS: EXCEPTIONALLY CLEAN, IN GOOD WORKING ORDER, AND E. NOTIFY ARCHITECT WHEN CLEANED COMPONENTS ARE READY FOR INSPECTION. 1. MANUFACTURERS - MECHANICAL ANCHORS: F. VARY TOTAL SYSTEM AIR QUANTITIES BY ADJUSTMENT OF FAN SPEEDS. PROVIDE DRIVE 1.1. HILT], INC: WWWUS.HILTI.COM SLE. CHANGES REQUIRED. VARY BRANCH AIR QUANTITIES BY DAMPER REGULATION. SEALED WHEN BROUGHT INTO THE FACILITY. F. NOTIFY OWNER'S TESTING AND INSPECTION AGENCY WHEN CLEANED COMPONENTS ARE READY � /# SECTION 23 0593 B. VACUUM DEVICES THAT EXHAUST AIR INSIDE BUILDING, INCLUDING HAND-HELD AND WET FOR INSPECTION. 1.2. ITW RED HEAD, A DIVISION OF ILLINOIS TOOL WORKS, INC: TESTING, ADJUSTING, AND BALANCING FOR HVAC G. PROVIDE SYSTEM SCHEMATIC WITH REQUIRED AND ACTUAL AIR QUANTITIES RECORDED AT OV NEy� G. OWNER RESERVES THE RIGHT TO VERIFY CLEANLINESS USING NADCA ACR SURFACE WWW.ITWREDHEAD.COM/#SLE. EACH OUTLET OR INLET. 't� G. y0 FOR MINIMUM 0.3-MICRON SIZE PARTICLES AND DOP TEST NUMBER. COMPARISON TESTING OR NADCA VACUUM TEST. 1.3. POWERS FASTENERS, INC: WWW.POWERS.COM/#SLE. VACUUMS: EQUIPPED WITH HEPA FILTRATION WITH 99.97 PERCENT COLLECTION EFFICIENCY PART 1 GENERAL H. MEASURE STATIC AIR PRESSURE CONDITIONS ON AIR SUPPLY UNITS, INCLUDING FILTER AND �� eF'�' � . r✓j P y H. WHEN DIRECTED, RE-CLEAN COMPONENTS UNTIL THEY PASS. 1.01 SECTION INCLUDES COIL PRESSURE DROPS, AND TOTAL PRESSURE ACROSS THE FAN. MAKE ALLOWANCES FOR * .Z� A * C. VACUUM DEVICES THAT EXHAUST AIR OUTSIDE BUILDING, INCLUDING TRUCK- AND 1.4. SIMPSON STRONG-TIE COMPANY INC: WWW.STRONGTIE.COM/#SLE. A. TESTING, ADJUSTMENT, AND BALANCING OF AIR SYSTEMS. 50 PERCENT LOADING OF FILTERS. �_ Q cr TRAILER-MOUNTED TYPES: EQUIPPED WITH PARTICULATE COLLECTION INCLUDING ADEQUATE I. CONTRACTOR SHALL BEAR THE COSTS OF RETESTING DUE TO INADEQUATE CLEANING. 1.5. APPROVED EQUAL. B. MEASUREMENT OF FINAL OPERATING CONDITION OF HVAC SYSTEMS. I. ADJUST OUTSIDE AIR AUTOMATIC DAMPERS, OUTSIDE AIR, RETURN AIR, AND EXHAUST n w FILTRATION TO CONTAIN DEBRIS REMOVED FROM THE HVAC SYSTEM; EXHAUSTED IN MANNER J. SUBMIT EVIDENCE THAT ALL PORTIONS OF THE SYSTEM REQUIRED TO BE CLEANED HAVE BEEN 2. MANUFACTURERS - POWDER-ACTUATED FASTENING SYSTEMS: DAMPERS FOR DESIGN CONDITIONS. y z THAT PREVENTS CONTAMINANT RE-ENTRY TO BUILDING; COMPLIANT WITH APPLICABLE CLEANED SATISFACTORILY. C. SOUND MEASUREMENT OF EQUIPMENT OPERATING CONDITIONS. REGULATIONS AS TO OUTDOOR ENVIRONMENTAL CONTAMINATION. 2.1. HILTI, INC: WWW.US.HILTI.COM/#SLE. D. VIBRATION MEASUREMENT OF EQUIPMENT OPERATING CONDITIONS. J. MEASURE TEMPERATURE CONDITIONS ACROSS OUTSIDE AIR, RETURN AIR, AND EXHAUST ��a 085 2,6 3.07 ANTI-MICROBIAL TREATMENT 2.2. ITW RAMSET, A DIVISION OF ILLINOIS TOOL WORKS, INC: WWW.RAMSET.COM SLE. DAMPERS TO CHECK LEAKAGE. '0 2.02 REPLACEMENT PRODUCTS /# 1.02 REFERENCE STANDARDS Rp� NP A. WHEN DIRECTED, APPLY ANTI-MICROBIAL TREATMENT TO INTERNAL SURFACES. 2.3. POWERS FASTENERS, INC: WWW.POWERS.COM/#SLE. A. ASHRAE STD 111 - MEASUREMENT, TESTING, ADJUSTING, AND BALANCING OF BUILDING HVAC K. MEASURE BUILDING STATIC PRESSURE AND ADJUST SUPPLY, RETURN, AND EXHAUST AIR ESS10 A. FIBROUS GLASS INSULATION: PROVIDE MATERIAL COMPLYING WITH UL 181 EQUIVALENT TO B. APPLY ANTI-MICROBIAL AGENT AFTER REMOVAL OF SURFACE DEPOSITS AND DEBRIS. SYSTEMS TO PROVIDE REQUIRED RELATIONSHIP BETWEEN EACH TO MAINTAIN APPROXIMATELY EXISTING MATERIAL IN QUALITY AND THICKNESS. C. APPLY ANTI-MICROBIAL TREATMENTS AND COATINGS IN STRICT ACCORDANCE WITH THE 2.4. SIMPSON STRONG-TIE COMPANY INC: WWW.STRONGTIE.COM/#SLE• SYSTEMS; 2008. 0.05 INCHES (12.5 PA) POSITIVE STATIC PRESSURE NEAR THE BUILDING ENTRIES. �2/22/2022 2.03 SURFACE TREATMENTS 2.5. APPROVED EQUAL. B. SMACNA (TAB) - HVAC SYSTEMS TESTING ADJUSTING AND BALANCING; 2002. A. ANTI-MICROBIAL MATERIALS: EPA REGISTERED SPECIFICALLY FOR USE ON NON-POROUS HVAC MANUFACTURERS WRITTEN RECOMMENDATIONS AND EPA REGISTRATION LISTING. 3.07 SCOPE „ 3. UNLESS OTHERWISE INDICATED AND WHERE NOT OTHERWISE RESTRICTED, USE THE ANCHOR 1.03 SUBMITTALS REVISIONS: D. SPRAY COATINGS DIRECTLY ONTO INTERIOR DUCTWORK SURFACES; DO NOT FOG INTO AIR AND FASTENER TYPES INDICATED FOR THE SPECIFIED APPLICATIONS. A. TEST, ADJUST, AND BALANCE THE FOLLOWING: SYSTEM SURFACES AND APPLIED PER MANUFACTURER'S INSTRUCTIONS. A. SEE SECTION 01 3000 - ADMINISTRATIVE REQUIREMENTS, FOR SUBMITTAL PROCEDURES. 1. AIR INLETS AND OUTLETS. 09-26-2022 OL RX REVIEW#1 STREAM. 4. CONCRETE: USE PRESET CONCRETE INSERTS, EXPANSION ANCHORS, OR SCREW ANCHORS. B. SURFACE COATING FOR FIBROUS GLASS MATERIALS: WATER-BASED ZERO VOC• FLAME B. TAB PLAN: SUBMIT A WRITTEN PLAN INDICATING THE TESTING ADJUSTING AND BALANCING ' 3.08 ADJUSTING 5. SOLID OR GROUT-FILLED MASONRY: USE EXPANSION ANCHORS OR SCREW ANCHORS. B. AIR DISTRIBUTION TESTS: SPREAD INDEX LESS THAT 25, SMOKE DEVELOPED INDEX LESS THAN 450, CLASS A, WHEN STANDARD TO BE FOLLOWED AND THE SPECIFIC APPROACH FOR EACH SYSTEM AND 09-27-2022 OL Rx REVIEW#2 TESTED IN ACCORDANCE WITH ASTM E84. A. AFTER SATISFACTORY COMPLETION OF FIELD QUALITY CONTROL ACTIVITIES, RESTORE 6. HOLLOW MASONRY: USE TOGGLE BOLTS. COMPONENT. 1. AIR TERMINAL NUMBER. PART 3 EXECUTION ADJUSTABLE DEVICES TO ORIGINAL SETTINGS, INCLUDING, BUT NOT LIMITED TO, DAMPERS, AIR 7• HOLLOW STUD WALLS: USE TOGGLE BOLTS. 1. INCLUDE AT LEAST THE FOLLOWING IN THE PLAN: 2. ROOM NUMBER/LOCATION. 09-27-2022 OL Rx REVIEW#3 DIRECTIONAL DEVICES, VALVES, FUSES, AND CIRCUIT BREAKERS. 3.01 PROJECT CONDITIONS 3.09 WASTE MANAGEMENT 8. STEEL: USE BEAM CLAMPS, MACHINE BOLTS OR WELDED THREADED STUDS. 1.1. LIST OF ALL AIR FLOW WATER FLOW SOUND LEVEL, SYSTEM CAPACITY AND 3. TERMINAL TYPE. A. COMPLY WITH APPLICABLE FEDERAL, STATE, AND LOCAL REQUIREMENTS. 9. SHEET METAL: USE SHEET METAL SCREWS. EFFICIENCY MEASUREMENTS TO BE PERFORMED AND A DESCRIPTION OF SPECIFIC TEST 4. TERMINAL SIZE. 10-03-2022 PL POST B. PERFORM CLEANING, INSPECTION, AND REMEDIATION IN ACCORDANCE WITH THE A. DOUBLE-BAG WASTE AND DEBRIS IN 6 MIL, 0.006 INCH (0.1524 MM) THICK POLYETHYLENE 10.WOOD: USE WOOD SCREWS. PROCEDURES, PARAMETERS, FORMULAS TO BE USED. 5. AREA FACTOR. 12-23-2022 BID/PERMIT SET RECOMMENDATIONS Of' NADCA "ASSESSMENT, CLEANING AND RESTORATION OF HVAC SYSTEMS" PLASTIC BAGS. 11.PLASTIC AND LEAD ANCHORS ARE NOT PERMITTED. 1.2. COPY OF FIELD CHECKOUT SHEETS AND LOGS TO BE USED, LISTING EACH PIECE OF 6. DESIGN VELOCITY. (ACR) AND AS SPECIFIED HEREIN. B. DISPOSE OF DEBRIS OFF-SITE IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL REQUIREMENTS 12•POWDER-ACTUATED FASTENERS ARE NOT PERMITTED. GATHERED FOR EACHEQUIPMENT TO BE TESTED, ADJUSTED AND BALANCED WITH THE DATA CELLS TO BE 7. DESIGN AIR FLOW.. C. WHERE NADCA ACR USES THE TERMS "RECOMMENDED", "HIGHLY RECOMMENDED", OR "IDEALLY" 12.1. WHERE APPROVED BY ARCHITECT. 8. TEST (FINAL) VELOCITY. 1.3. DISCUSSION OF WHAT NOTATIONS AND MARKINGS WILL BE MADE ON THE DUCT AND IN REGARD TO A CERTAIN PROCEDURE OR ACTIVITY, DO THAT UNLESS IT IS CLEARLY 12.2. USE ONLY THREADED STUDS; DO NOT USE PINS. 9. TEST (FINAL) AIR FLOW, SECTION 23 0529 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PIPING DRAWINGS DURING THE PROCESS. PART 1 PRODUCTS 1.4. FINAL TEST REPORT FORMS TO BE USED. INAPPLICABLE TO THE PROJECT. 13.HAMMER-DRIVEN ANCHORS AND FASTENERS ARE NOT PERMITTED. 1C.PERCENT OF DESIGN AIR FLOW. D. TAKE PRECAUTIONS TO PREVENT INTRODUCTION OF ADDITIONAL HAZARDS INTO OCCUPIED 1.01 SUPPORT AND ATTACHMENT COMPONENTS 13.1. NAILS ARE PERMITTED FOR ATTACHMENT OF NONMETALLIC BOXES TO WOOD FRAME 1.5. PROCEDURES FOR FORMAL DEFICIENCY REPORTS, INCLUDING SCOPE, FREQUENCY AND C. SOUND LEVEL REPORTS: SPACES. A. GENERAL REQUIREMENTS: CONSTRUCTION (WHEN SPECIFIED). DISTRIBUTION. 1. LOCATION. E. COMPLY WITH REQUIREMENTS OF SECTION D1 5719. 2. PROVIDE ALL REQUIRED HANGERS, SUPPORTS, ANCHORS, FASTENERS, FITTINGS, 13.2. STAPLES ARE PERMITTED FOR ATTACHMENT OF NONMETALLIC-SHEATHED CABLE TO 2. OCTAVE BANDS - EQUIPMENT OFF. 1. COMPLY WITH MSS SP-58. C. FINAL REPORT: INDICATE DEFICIENCIES IN SYSTEMS THAT WOULD PREVENT PROPER TESTING, F. OBTAIN OWNER'S APPROVAL OF PROPOSED TEMPORARY LOCATIONS FOR LARGE EQUIPMENT. WOOD FRAME CONSTRUCTION (WHEN SPECIFIED). ADJUSTING, AND BALANCING OF SYSTEMS AND EQUIPMENT TO ACHIEVE SPECIFIED 3. OCTAVE BANDS - EQUIPMENT ON. DRAWING BY: CJS G. DESIGNATE A DECONTAMINATION AREA AND OBTAIN OWNER'S APPROVAL. ACCESSORIES, AND HARDWARE AS NECESSARY FOR THE COMPLETE INSTALLATION OF 14.PRESET CONCRETE INSERTS: CONTINUOUS METAL CHANNEL (STRUT) AND SPOT INSERTS PERFORMANCE. H. WHEN PORTIONS OF THE FACILITY ARE TO REMAIN OCCUPIED OR IN OPERATION DURING PLUMBING WORK. SPECIFICALLY DESIGNED TO BE CAST IN CONCRETE CEILINGS, WALLS, AND FLOORS. 1. REVISE TAB PLAN TO REFLECT ACTUAL PROCEDURES AND SUBMIT AS PART OF FINAL CHECKED BY: BC CLEANING ACTIVITIES, PROVIDE ADEQUATE CONTROLS OR CONTAINMENT TO PREVENT ACCESS TO 3. PROVIDE PRODUCTS LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSE 14,1. COMPLY WITH MFMA-4. REPORT. SPACES BEING CLEANED BY UNAUTHORIZED PERSONS AND PROVIDE DETAILED INSTRUCTIONS INTENDED, WHERE APPLICABLE. 14.2. CHANNEL MATERIAL: USE GALVANIZED STEEL. 2. SUBMIT DRAFT COPIES OF REPORT FOR REVIEW PRIOR TO FINAL ACCEPTANCE OF PROJECT. DATE: 09-22-2022 TO OWNER AS TO THESE CONTROLS OR CONTAINMENT. 4. WHERE SUPPORT AND ATTACHMENT COMPONENT TYPES AND SIZES ARE NOT INDICATED, 14.3. MINIMUM CHANNEL THICKNESS: STEEL SHEET, 12 GAGE, 0.1046 INCH (2.66 MM) PROVIDE FINAL COPIES FOR ARCHITECT AND FOR INCLUSION IN OPERATING AND I. IF UNFORESEEN MOLD OR OTHER BIOLOGICAL CONTAMINATION IS ENCOUNTERED, NOTIFY SELECT IN ACCORDANCE WITH MANUFACTURER'S APPLICATION CRITERIA AS REQUIRED FOR MINIMUM BASE METAL THICKNESS. MAINTENANCE MANUALS. JOB NUMBER: 022139 ARCHITECT IMMEDIATELY, IDENTIFYING AREAS AFFECTED AND EXTENT AND TYPE OF THE LOAD TO BE SUPPORTED WITH A MINIMUM SAFETY FACTOR OF ------ INCLUDE 14.4. MANUFACTURER: SAME AS MANUFACTURER OF METAL CHANNEL (STRUT) FRAMING 3. INCLUDE ACTUAL INSTRUMENT LIST, WITH MANUFACTURER NAME, SERIAL NUMBER, AND CONTAMINATION. CONSIDERATION FOR VIBRATION, EQUIPMENT OPERATION, AND SHOCK LOADS WHERE SYSTEM. DATE OF CALIBRATION. TITLE: 3.02 EXAMINATION APPLICABLE. 15.POST-INSTALLED CONCRETE AND MASONRY ANCHORS: EVALUATED AND RECOGNIZED BY 4. FORM OF TEST REPORTS: WHERE THE TAB STANDARD BEING FOLLOWED RECOMMENDS A MECHANICAL A. PRIOR TO THE COMMENCEMENT OF ANY CLEANING WORK, PREPARE AND SUBMIT TO ARCHITECT 5. DO NOT USE WIRE, CHAIN, PERFORATED PIPE STRAP, OR WOOD FOR PERMANENT SUPPORTS ICC EVALUATION SERVICE, LLC (ICC-ES) FOR COMPLIANCE WITH APPLICABLE BUILDING REPORT FORMAT USE THAT; OTHERWISE, FOLLOW ASHRAE STD 111. A PROJECT EVALUATION AND PLAN FOR THS PROJECT, INCLUDING CONSIDERATIONS UNLESS SPECIFICALLY INDICATED OR PERMITTED. CODE. 5. UNITS OF MEASURE: REPORT DATA IN BOTH I-P (INCH-POUND) AND SI (METRIC) UNITS. SPECIFICATIONS RECOMMENDED IN NADCA ACR. 6. STEEL COMPONENTS: USE CORROSION RESISTANT MATERIALS SUITABLE FOR THE PART 2 EXECUTION PART 2 PRODUCTS - NOT USED B. COORDINATE CLEANING PLAN WITH INDOOR AIR QUALITY CONTROL PLAN SPECIFIED IN SECTION ENVIRONMENT WHERE INSTALLED. 2.01 EXAMINATION PART 3 EXECUTION SHEET NUMBER: 01 5719. 6.1. INDOOR DRY LOCATIONS: USE ZINC-PLATED STEEL OR APPROVED EQUIVALENT UNLESS OTHERWISE INDICATED. A. VERIFY THAT FIELD MEASUREMENTS ARE AS INDICATED. 3.01 GENERAL REQUIREMENTS C. INSPECT THE SYSTEM AS REQUIRED TO DETERMINE APPROPRIATE METHODS, TOOLS, EQUIPMENT, B. VERIFY THAT MOUNTING SURFACES ARE READY TO RECEIVE SUPPORT AND ATTACHMENT A. PERFORM TOTAL SYSTEM BALANCE IN ACCORDANCE WITH ONE OF THE FOLLOWING: AND PROTECTION. 6.2. OUTDOOR AND DAMP OR WET INDOOR LOCATIONS: USE GALVANIZED STEEL, STAINLESS COMPONENTS. D. START OF CLEANING WORK CONSTITUTES ACCEPTANCE OF EXISTING CONDITIONS. STEEL, OR APPROVED EQUIVALENT UNLESS OTHERWISE INDICATED. r 6.3. ZINC-PLATED STEEL: ELECTROPLATED IN ACCORDANCE WITH ASTM B633. C. VERIFY THAT CONDITIONS ARE SATISFACTORY FOR INSTALLATION PRIOR TO STARTING WORK. mmi w E. WHEN CONCEALED SPACES ARE LATER MADE ACCESSIBLE, EXAMINE AND DOCUMENT INTERIOR NEWYORKALTERATION WARNING STATEMENT: z CONDITIONS PRIOR TO BEGINNING CLEANING. 6.4. GALVANIZED STEEL: HOT-DIP GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH 2.02 INSTALLATION IT IS A VIOLATION OF THE NEW YORK EDUCATION LAW,ARTICLE 145,SECTION COMMENTS: W ASTM A123 A123M OR ASTM A153 A153M. A. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 7209 FOR ANY PERSON,UNLESS THE INDIVIDUAL IS ACTING UNDER THE m F. DOCUMENT ALL INSTANCES OF MOLD GROWTH, RODENT DROPPINGS, OTHER BIOLOGICAL / / d HAZARDS, AND DAMAGED SYSTEM COMPONENTS, 6.5. OR APPROVED EQUIVALENT UNLESS OTHERWISE INDICATED. B. INSTALL ANCHORS AND FASTENERS IN ACCORDANCE WITH ICC EVALUATION SERVICES, LLC DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, E ALTER AN ITEM IN ICC-ES EVALUATION REPORT CONDITIONS OF USE WHERE APPLICABLE. ANY WAY.IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE w B. MATERIALS FOR METAL FABRICATED SUPPORTS: COMPLY WITH SECTION 05 5000. ( ) ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE 0-1 NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF 0 Q SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. SECTION 23 0713 INSULATION. C. PRICE INDUSTRIES: WWW.PRICE-HVAC.COM/#SLE. D. INCREASE DUCT SIZES GRADUALLY NOT EXCEEDING 15 DEGREES DIVERGENCE WHEREVER DUCT INSULATION D. TITUS, A BRAND OF AIR DISTRIBUTION TECHNOLOGIES: WWW.TITUS-HVAC.COM. POSSIBLE; MAXIMUM 30 DEGREES DIVERGENCE UPSTREAM OF EQUIPMENT AND 45 DEGREES PART 1 GENERAL CONVERGENCE DOWNSTREAM. 2.02 RECTANGULAR CEILING DIFFUSERS 1.01 SECTION INCLUDES E. FABRICATE CONTINUOUSLY WELDED ROUND AND OVAL DUCT FITTINGS IN ACCORDANCE WITH A. TYPE: PROVIDE SQUARE, STAMPED, MULTI-CORE, SQUARE, ADJUSTABLE PATTERN, STAMPED, A. DUCT INSULATION. SMACNA (DCS). MULTI-CORE, SQUARE AND RECTANGULAR, MULTI-LOUVERED, AND SQUARE AND RECTANGULAR, - I 1.02 REFERENCE STANDARDS ADJUSTABLE PATTERN DIFFUSER TO DISCHARGE AIR IN 360 DEGREE, ONE WAY, TWO WAY, 2.04 MANUFACTURED DUCTWORK AND FITTINGS THREE WAY, AND FOUR WAY PATTERN WITH SECTORIZING BAFFLES WHERE INDICATED. A. ASTM C518 - STANDARD TEST METHOD FOR STEADY-STATE THERMAL TRANSMISSION A. FLEXIBLE DUCTS: UL 181, CLASS 1, ALUMINUM LAMINATE AND POLYESTER FILM WITH LATEX PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS; 2017. ADHESIVE SUPPORTED BY HELICALLY WOUND SPRING STEEL WIRE. C. FRAME: PROVIDE SNAP-IN TYPE. IN PLASTER CEILINGS, PROVIDE PLASTER FRAME AND B. CONNECTIONS: ROUND. 1M B. ASTM C553 - STANDARD SPECIFICATION FOR MINERAL FIBER BLANKET THERMAL INSULATION 1. PRESSURE RATING: 10 INCHES WG (2.50 KPA) POSITIVE AND 1.0 INCHES WG (250 PA) CEILING FRAME. FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS; 2013. NEGATIVE. C. ASTM E84 - STANDARD TEST METHOD FOR SURFACE BURNING CHARACTERISTICS OF BUILDING D. FABRICATION: STEEL WITH BAKED ENAMEL FINISH. 2. MAXIMUM VELOCITY: 4000 FPM (20.3 M/SEC). MATERIALS; 2018. 3. TEMPERATURE RANGE: MINUS 20 DEGREES F TO 210 DEGREES F (MINUS 28 DEGREES C E. COLOR: AS INDICATED. Reset + Rx DI Ital Screen D. ASTM E96/E96M - STANDARD TEST METHODS FOR WATER VAPOR TRANSMISSION OF TO 99 DEGREES C). MATERIALS; 2016. Expansion + P oto E. UL 723 - STANDARD FOR TEST FOR SURFACE BURNING CHARACTERISTICS OF BUILDING 4. MANUFACTURERS: MATERIALS; CURRENT EDITION, INCLUDING ALL REVISIONS. 4.1. HART & COOLEY, INC: WWW.HARTAND000LEY.COM. STORE NUMBER 3105 1.03 DELIVERY, STORAGE, AND HANDLING 4.2. THERMAFLEX, M-KC. A. ACCEPT MATERIALS ON SITE IN ORIGINAL FACTORY PACKAGING, LABELLED WITH PART 3 EXECUTION 9870 MAIN ROAD MANUFACTURER'S IDENTIFICATION, INCLUDING PRODUCT DENSITY AND THICKNESS. 3.01 INSTALLATION B. PROTECT INSULATION FROM WEATHER AND CONSTRUCTION TRAFFIC, DIRT, WATER, CHEMICAL, A. INSTALL, SUPPORT, AND SEAL DUCTS IN ACCORDANCE WITH SMACNA (DCS). MATTITUCK, NY 11952 AND MECHANICAL DAMAGE, BY STORING IN I ORIGINAL WRAPPING. B. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. PROJECT TYPE: (72 & 182) 1.04 FIELD CONDITIONS C. DURING CONSTRUCTION PROVIDE TEMPORARY CLOSURES OF METAL OR TAPED POLYETHYLENE A. MAINTAIN AMBIENT TEMPERATURES AND CONDITIONS REQUIRED BY MANUFACTURERS OF ON OPEN DUCTWORK TO PREVENT CONSTRUCTION DUST FROM ENTERING DUCTWORK SYSTEM. ADHESIVES, MASTICS, AND INSULATION CEMENTS. D. FLEXIBLE DUCTS: CONNECT TO METAL DUCTS WITH ADHESIVE PLUS SHEET METAL SCREWS. CS PROJECT NUMBER: 165265 B. MAINTAIN TEMPERATURE DURING AND AFTER INSTALLATION FOR MINIMUM PERIOD OF 24 E. DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS. FOR LINED DUCTS, MAINTAIN SIZES HOURS. INSIDE LINING. PART 2 PRODUCTS F. LOCATE DUCTS WITH SUFFICIENT SPACE AROUND EQUIPMENT TO ALLOW NORMAL OPERATING 2.01 REGULATORY REQUIREMENTS AND MAINTENANCE ACTIVITIES. ARCHITECT OF RECORD: A. SURFACE BURNING CHARACTERISTICS: FLAME SPREAD INDEX/SMOKE DEVELOPED INDEX OF G. USE DOUBLE NUTS AND LOCK WASHERS ON THREADED ROD SUPPORTS. 25/50, MAXIMUM, WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723. H. CONNECT DIFFUSERS OR LIGHT TROFFER BOOTS TO LOW PRESSURE DUCTS DIRECTLY OR WITH 2.02 GLASS FIBER, FLEXIBLE 5 FEET (1.5 M) MAXIMUM LENGTH OF FLEXIBLE DUCT HELD IN PLACE WITH STRAP OR CLAMP. A. MANUFACTURER: 3.02 CLEANINGL 12.JOHNS MANVILLE: WWW.JM.COM. A. CLEAN DUCT SYSTEM AND FORCE AIR AT HIGH VELOCITY THROUGH DUCT TO REMOVE �` ' v, '' 13.KNAUF INSULATION; ATMOSPHERE DUCT WRAP: WWW.KNAUFINSULATION.COM/#SLE. ACCUMULATED DUST. TO OBTAIN SUFFICIENT AIR, CLEAN HALF THE SYSTEM AT A TIME. 14.OWENS CORNING CORPORATION: WWW.00BUILDINGSPEC.COM. PROTECT EQUIPMENT THAT COULD BE HARMED BY EXCESSIVE DIRT WITH TEMPORARY FILTERS, 15.CERTAINTEED CORPORATION: WWW.CERTAINTEED.COM. OR BYPASS DURING CLEANING. SBLM B. INSULATION: ASTM 0553; FLEXIBLE, NONCOMBUSTIBLE BLANKET. 545 West 45th Street 4th Floor 1. 'K' ('KSI') VALUE: 0.36 AT 75 DEGREES F (0.052 AT 24 DEGREES C), WHEN TESTED IN SECTION 23 New York, NY 10036 ACCORDANCE WITH ASTM C518. AIR DUCT ACCESSORIES T: 212.995.5600 2. MAXIMUM SERVICE TEMPERATURE: 1200 DEGREES F (649 DEGREES C). PART 1 GENERAL www.sblm.com 3. MAXIMUM WATER VAPOR ABSORPTION: 5.0 PERCENT BY WEIGHT. 1.01 SECTION INCLUDES C. VAPOR BARRIER JACKET: A. AIR TURNING DEVICES/EXTRACTORS. 1. KRAFT PAPER WITH GLASS FIBER YARN AND BONDED TO ALUMINIZED FILM. B. FLEXIBLE DUCT CONNECTIONS. 2. MOISTURE VAPOR !PERMEABILITY: 0.02 PERM INCH (0.029 NG/PA S M), WHEN TESTED IN C. VOLUME CONTROL DAMPERS, CONSULTANT ENGINEER' ACCORDANCE WITH ASTM E96/E96M. 1.02 RELATED REQUIREMENTS 3. SECURE WITH PRESSURE SENSITIVE TAPE. A. SECTION 23 3100 - HVAC DUCTS AND CASINGS. D. VAPOR BARRIER TAPE:: 1.03 REFERENCE STANDARDS 1. KRAFT PAPER REINFORCED WITH GLASS FIBER YARN AND BONDED TO ALUMINIZED FILM, A. NFPA 90A - STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING CONSULTING WITH PRESSURE SENSITIVE RUBBER BASTED ADHESIVE. SYSTEMS; 2018. E. TIE WIRE: ANNEALED STEEL, 16 GAGE, 0.0508 INCH DIAMETER (1.29 MM DIAMETER). B. SMACNA (DCS) - HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE; 2005 ENGINEERS 240 WEST 37TH STREET,3RD FLOOR PART 3 EXECUTION (REVISED 2009). NEW YORK,NY 10018 3.01 EXAMINATION 1.04 QUALITY ASSURANCE TEL 212.413.8400 A. VERIFY THAT DUCTS HAVE BEEN TESTED BEFORE APPLYING INSULATION MATERIALS. A. MANUFACTURER QUALIFICATIONS: COMPANY SPECIALIZING IN MANUFACTURING THE TYPE OF www.fhny-eng.eom B. VERIFY THAT SURFACES ARE CLEAN, FOREIGN MATERIAL REMOVED, AND DRY, PRODUCTS SPECIFIED IN THIS SECTION, WITH MINIMUM THREE YEARS OF DOCUMENTED 2250003925 3.02 INSTALLATION EXPERIENCE. A. INSTALL IN ACCORDANCE WITH MANUFACTU'RER'S INSTRUCTIONS. B. PRODUCTS REQUIRING ELECTRICAL CONNECTION: LISTED AND CLASSIFIED BY UNDERWRITERS LABORATORIES INC. AS SUITABLE FOR THE PURPOSE SPECIFIED AND INDICATED. B. INSTALL IN ACCORDANCE WITH NAIMA NATIONAL INSULATION STANDARDS. 1.05 DELIVERY, STORAGE, AND HANDLING CONSULTANT' C. INSULATED DUCTS CONVEYING AIR BELOW AMBIENT TEMPERATURE: A. PROTECT DAMPERS FROM DAMAGE TO OPERATING LINKAGES AND BLADES. 1. PROVIDE INSULATION WITH VAPOR BARRIER JACKETS. PART 2 PRODUCTS 2. FINISH WITH TAPE AND VAPOR BARRIER JACKET. 2.01 AIR TURNING DEVICES/EXTRACTORS 3. CONTINUE INSULATION THROUGH WALLS, SLEEVES, HANGERS, AND OTHER DUCT A. MANUFACTURERS: PENETRATIONS. 1. KRUEGER-HVAC, DIVISION OF AIR SYSTEM COMPONENTS: WWW.KRUEGER-HVAC.COM. 4. INSULATE ENTIRE SYSTEM INCLUDING FITTINGS, JOINTS, FLANGES, FIRE DAMPERS, FLEXIBLE 2. RUSKIN COMPANY, A BRAND OF JOHNSON CONTROLS: WWW.RUSKIN.COM. CONNECTIONS, AND EXPANSION JOINTS. 3. TITUS HVAC, A BRAND OF JOHNSON CONTROLS: WWW.TITUS-HVAC.COM. SECTION 23 3100 B. MULTI-BLADE DEVICE WITH BLADES ALIGNED IN SHORT DIMENSION; STEEL CONSTRUCTION; WITH INDIVIDUALLY ADJUSTABLE BLADES, MOUNTING STRAPS. HVAC DUCTS AND CASINGS 2.02 FLEXIBLE DUCT CONNECTIONS PART 1 GENERAL A. MANUFACTURERS: 1.01 SECTION INCLUDES 1. CARLISLE HVAC PRODUCTS; DYNAIR CONNECTOR PLUS G90 STEEL OFFSET SEAM NEOPRENE A. METAL DUCTWORK. FABRIC: WWW.CARLISLEHVAC.COM/#SLE. B. DUCT CLEANING. 2. ELGEN MANUFACTURING, INC: WWW.ELGENMFG.COM. 1.02 REFERENCE STANDARDS B. FABRICATE IN ACCORDANCE WITH SMACNA (DCS) AND AS INDICATED. SEAL: A. ASTM A36/A36M - STANDARD SPECIFICATION FOR CARBON STRUCTURAL STEEL; 2014. C. FLEXIBLE DUCT CONNECTIONS: FABRIC CRIMPED INTO METAL EDGING STRIP. B. ASTM A653/A653M - STANDARD SPECIFICATION FOR STEEL SHEET, ZINC-COATED 1. FABRIC: UL LISTED FIRE-RETARDANT NEOPRENE COATED WOVEN GLASS FIBER FABRIC TO (GALVANIZED) OR ZINC-IRON ALLOY-COATED (GALVANNEALED) BY THE HOT-DIP PROCESS; NFPA 90A, MINIMUM DENSITY 30 OZ PER SQ YD (1.0 KG/SQ M). OF NEW 2017. G.1.1. NET FABRIC WIDTH: APPROXIMATELY 2 INCHES (50 MM) WIDE. �,�Q�Q BFy�O,A� C. ASTM E84 - STANDARD TEST METHOD FOR SURFACE BURNING CHARACTERISTICS OF BUILDING 2. METAL: 3 INCHES (75 MM) WIDE, 24 GAGE, 0.0239 INCH (0.61 MM) THICK GALVANIZED * MATERIALS; 2018. STEEL. ,- D. NFPA 90A - STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING A. MAXIMUM INSTALLED LENGTH: 14 INCH 356 MM). n 2 ( ) SYSTEMS; 2018. m E. SMACNA (DCS) - HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE; 2005 2.03 VOLUME CONTROL DAMPERS A. (REVISED 2009). A. MANUFACTURERS: SOA 085526 F. UL 181 - STANDARD FOR FACTORY-MADE AIR DUCTS AND AIR CONNECTORS; CURRENT 1. LOUVERS & DAMPERS, INC, A BRAND OF MESTEK, INC: WWW.LOUVERS-DAMPERS.COM. R0PE5610 EDITION, INCLUDING ALL REVISIONS. 2. NAILOR INDUSTRIES, INC: WWW.NAILOR.COM. 12/22/2022 1.03 QUALITY ASSURANCE 3. RUSKIN COMPANY, A BRAND OF JOHNSON CONTROLS: WWW.RUSKIN.COM. A. MANUFACTURER QUALIFICATIONS: COMPANY SPECIALIZING IN MANUFACTURING THE TYPE OF B. FABRICATE IN ACCORDANCE WITH SMACNA (DCS) AND AS INDICATED, REVISIONS: PRODUCTS SPECIFIED IN THIS SECTION, WITH MINIMUM THREE YEARS OF DOCUMENTED C. SINGLE BLADE DAMPERS: EXPERIENCE, AND APPROVED BY MANUFACTURER. 1. FABRICATE FOR DUCT SIZES UP TO 6 BY 30 INCH (150 BY 760 MM). 09-26-2022 OL Rx REVIEW#1 B. INSTALLER QUALIFICATIONS: COMPANY SPECIALIZING IN PERFORMING THE TYPE OF WORK 2. BLADE: 24 GAGE, 0.0239 INCH (0.61 MM), MINIMUM. SPECIFIED IN THIS SECTION, WITH MINIMUM 3 YEARS OF DOCUMENTED EXPERIENCE. D. MULTI-BLADE DAMPER: FABRICATE OF OPPOSED BLADE PATTERN WITH MAXIMUM BLADE 09-27-2022 OL Rx REVIEW#2 1.04 FIELD CONDITIONS SIZES 8 BY 72 INCH (200 BY 1825 MM). ASSEMBLE CENTER AND EDGE CRIMPED BLADES IN 09-27-2022 OL Rx REVIEW#3 A. DO NOT INSTALL DUCT SEALANTS WHEN TEMPERATURES ARE LESS THAN THOSE PRIME COATED OR GALVANIZED CHANNEL FRAME WITH SUITABLE HARDWARE. RECOMMENDED BY SEALANT MANUFACTURERS. 1. BLADE: 18 GAGE, 0.0478 INCH (1.21 MM), MINIMUM. 10-03-2022 PL POST B. MAINTAIN TEMPERATURES WITHIN ACCEPTABLE RANGE DURING AND AFTER INSTALLATION OF E. QUADRANTS: 12-23-2022 BID/PERMIT SET DUCT SEALANTS. 1. PROVIDE LOCKING, INDICATING QUADRANT REGULATORS ON SINGLE AND MULTI-BLADE PART 2 PRODUCTS DAMPERS. 2.01 DUCT ASSEMBLIES 2. ON INSULATED DUCTS MOUNT QUADRANT REGULATORS ON STAND-OFF MOUNTING A. REGULATORY REQUIREMENTS: CONSTRUCT DUCTWORK TO NFPA 90A STANDARDS. BRACKETS, BASES, OR ADAPTERS. B. DUCTS: GALVANIZED STEEL, UNLESS OTHERWISE INDICATED. 3. MANUFACTURERS: C. LOW PRESSURE SUPPLY (SYSTEM WITH COOLING COILS): 2 INCH W.G. (500 PA) PRESSURE A. CARLISLE HVAC PRODUCTS; DYNAIR DOUBLE SHEAR RATTLE FREE QUADRANTS 1/2 INCH: CLASS, GALVANIZED STEEL. WWW.CARLISLEHVAC.COM/#SLE. D. RETURN AND RELIEF: 1 INCH W.G. (250 PA) PRESSURE CLASS, GALVANIZED STEEL. PART 3 EXECUTION E. GENERAL EXHAUST: 1/2 INCH W.G. (125 PA) PRESSURE CLASS, GALVANIZED STEEL. 3.01 INSTALLATION DRAWING BY: CJS F. TRANSFER AIR AND SOUND BOOTS: 1/2 INCH W.G. (125 PA) PRESSURE CLASS, FIBROUS A. INSTALL ACCESSORIES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, NFPA 90A, GLASS. AND FOLLOW SMACNA (DCS). REFER TO SECTION 23 3100 FOR DUCT CONSTRUCTION AND CHECKED BY: BC 2.02 MATERIALS PRESSURE CLASS. A. GALVANIZED STEEL FOR DUCTS: HOT-DIPPED GALVANIZED STEEL SHEET, ASTM A653/A653M B. AT FANS AND MOTORIZED EQUIPMENT ASSOCIATED WITH DUCTS, PROVIDE FLEXIBLE DUCT DATE: 09-22-2022 FS TYPE B, WITH G60/Z180 COATING. CONNECTIONS IMMEDIATELY ADJACENT TO THE EQUIPMENT. B. JOINT SEALERS AND SEALANTS: NON-HARDENING, WATER RESISTANT, MILDEW AND MOLD C. PROVIDE BALANCING DAMPERS AT POINTS ON SUPPLY, RETURN, AND EXHAUST SYSTEMS RESISTANT. WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS AS REQUIRED FOR AIR BALANCING. JOB NUMBER: 022139 1. TYPE: HEAVY MASTIC OR LIQUID USED ALONE OR WITH TAPE, SUITABLE FOR JOINT INSTALL MINIMUM 2 DUCT WIDTHS FROM DUCT TAKE-OFF. CONFIGURATION AND COMPATIBLE WITH SUBSTRATES, AND RECOMMENDED BY D. PROVIDE BALANCING DAMPERS ON DUCT TAKE-OFF TO DIFFUSERS, GRILLES, AND REGISTERS, TITLE: MANUFACTURER FOR PRESSURE CLASS DF DUCTS. REGARDLESS OF WHETHER DAMPERS ARE SPECIFIED AS PART OF THE DIFFUSER, GRILLE, OR MECHANICAL 2. SURFACE BURNING CHARACTERISTICS: FLAME SPREAD INDEX OF ZERO AND SMOKE REGISTER ASSEMBLY. DEVELOPED INDEX OF ZERO, WHEN TESTED IN ACCORDANCE WITH ASTM E84. SPECIFICATIONS 3. FOR USE WITH FLEXIBLE DUCTS: UL LABELED. SECTION 23 3700 C. HANGER ROD: ASTM A36/A36M; STEEL, GALVANIZED; THREADED BOTH ENDS, THREADED AIR OUTLETS AND INLETS SHEET NUMBER: ONE END, OR CONTINUOUSLY THREADED. PART 1 GENERAL 2.03 DUCTWORK FABRICATION 1.01 SECTION INCLUDES A. FABRICATE AND SUPPORT IN ACCORDANCE WITH SMACNA (DCS) AND AS INDICATED. A. DIFFUSERS, W B. PROVIDE DUCT MATERIAL, GAGES, REINFORCING, AND SEALING FOR OPERATING PRESSURES B. REGISTERS/GRILLES. NEW YORK ALTERATION WARNING STATEMENT: z INDICATED. PART 2 PRODUCTS IT IS A VIOLATION OF THE NEW YORK EDUCATION LAW,ARTICLE 145,SECTION COMMENTS: W C. CONSTRUCT T'S, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1-1/2 TIMES WIDTH 2.01 MANUFACTURERS 7209 FOR ANY PERSON,UNLESS THE INDIVIDUAL IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AN ITEM IN OF DUCT ON CENTERLINE. WHERE NOT POSSIBLE AND WHERE RECTANGULAR ELBOWS MUST A. METALAIRE, A BRAND OF METAL INDUSTRIES: WWW.METALAIRE.COM. ANY WAY.IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE ui BE USED, PROVIDE Alf? FOIL TURNING VANES OF PERFORATED METAL WITH GLASS FIBER B. KRUEGER-HVAC, DIVISION OF AIR SYSTEM COMPONENTS: WWW.KRUEGER-HVAC.COM ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. NOTES 1. GENERAL NOTES ARE APPLICABLE TO 8. REFER TO DETAILS ON THIS SHEET FOR ALL HVAC DRAWINGS. DIFFUSER/GRILLE INSTALLATION. 2. PERFORM WORK IN ACCORDANCE WITH g, CVS/PHARMACY HAS ENTERED INTO A THE LATEST EDITIONS, REVISIONS, NATIONAL ACCOUNT AGREEMENT WITHTM AMENDMENTS, OR SUPPLEMENTS OF CPC FOR FURNISHING THE ENERGY APPLICABLE STATUTES, ORDINANCES, MANAGEMENT SYSTEM. FOR FURTHER phat"macy CODES OR REGULATIONS OF FEDERAL, INFORMATION, CALL CPC AT (800) STATE, AND LOCAL AUTHORITIES HAVING 929-2724. AS PART OF THIS SYSTEM, ital Screen Reset + Rx Di JURISDICTION IN EFFECT ON THE DATE TEMPORARY THERMOSTATS FOR THE BIDS ARE RECEIVED. ROOFTOP UNITS SHALL BE PROVIDED BY Expansion + P oto 3. WHERE APPROVED STANDARDS HAVE THE HVAC CONTRACTOR TO TEST AND BALANCE THE HVAC EQUIPMENT PRIOR UNDERWRITERS LABORATORIES, AMERICAN BEEN ESTABLISHED OSHA, TO FINAL INSTALLATION OF SENSORS BY STORE NUMBER: 3105 THE EMS CONTRACTOR. CONTRACTOR CODES, ASA, ASHR ARI, NEC, STATE SHALL VERIFY TEMPORARY THERMOSTATS 9870 MAIN ROAD FIRE INSURANCE REGULATION ULATION BODY, ARE MOUNTED AT LOCATIONS INDICATED. NFPA OR OTHERS. THESE STANDARDS MATTITUCK, NY 11952 SHALL BE FOLLOWED WHETHER OR NOT 10. THE DRAWINGS AND SPECIFICATIONS ARE PROJECT TYPE: 72 & 182 INDICATED ON THE DRAWING AND PRODUCED REPRESENTING WORK TO BE SPECIFICATIONS. DONE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL 4. ALL DUCT TO BE OF 2 PRESSURE CODES. THE LOCAL CODE AUTHORITY CS CLASS, UNLESS NOTED OTHERWISE. HAS THE AUTHORITY TO INTERPRET PROJECT NUMBER 165265 CODE REQUIREMENTS IN THEIR 5. LIGHT FIXTURE LOCATIONS TAKE JURISDICTION. THESE INTERPRETATIONS PRECEDENCE OVER DIFFUSER AND GRILLE MAY VARY FROM INFORMATION ARCHITECT OF RECORD LOCATIONS. LOCATE DIFFUSERS AND PRESENTED IN THE DOCUMENTS. THE GRILLES TO ACCOMMODATE LIGHTING CONTRACTOR SHALL INFORM THE LAYOUT. OWNER'S REPRESENTATIVE AND THE ARCHITECT-ENGINEER, OF RECORD, OF 6, DUCT SIZES SHOWN ARE NET FREE g AREA. THE DIFFERENCES AND SHALL PROCEED WITH THE WORK UPON RECEIVING THEIR 7. DUCTWORK SHALL NOT BE SUPPORTED AGREEMENT WITH THE LOCAL CODE FROM BRIDGING. DO NOT USE AUTHORITY INTERPRETATION. FASTENERS THAT PENETRATE ROOF SBLM RG-1 DECK. 545 West 45th Street 4th Floor WTG- 1 New York, NY 10036 RECEIVING AREA 2 30"x18" LEGEND T: .sblm.5om www.sblm.com VESTIBULE 106 A Q AHU REMOTE CONTROLLER 100 EMS O CONTACTS (800) 829EMERSON CLIMATE TECH SOLUTIONS. WTG_ 1 RETAIL S CONSULTANT ENGINEER: 30"x18" 101 (D NOTES BY SYMBOL ® SUPPLY AIR DIFFUSERS: CONSULTING ENGINEERS 240 WEST 37TH STREET,3RD FLOOR ® NEW YORK,NY 10018 RETURN AIR DIFFUSERS: TEL 212.413.8400 www.hny-ong.eom 2250003925 CFM CUBIC FEET NK NECK PER MINUTE AFF ABOVE FINISHED DN. DOWN FLOOR CD CONDENSATE DRAIN EXH. EXHAUST SA SUPPLY AIR REQ'D REQUIRED CONSULTANT' RA RETURN AIR DMPR DAMPER FD FIRE DAMPER SD SUPPLY AIR DIFFUSER RHC REHEAT COIL RG RETURN AIR GRILLE MECHANICAL PLAN - VESTIBULE 0 MECHANICAL PLAN - DOOR M-2 SCALE: 1/4" = 1'-0" �-2SCALE: 1/2" = 1'-0" MAIN SUPPLY DUCT NOTES BY SYMBOL OR SUB-MAIN lO REPLACE ACT WITH NEW 24"X48" RG-1 AS SCHEDULED. MIN. 1 W, 4" O2 INSTALL WTG-1 (TYP 2) AT HEIGHT NSHOWN ON ARCHITECTURAL ELEVATION. BRANCH DUCT ROUTE 30"X18" LINED DUCTWORK PROVIDE OPPOSED BETWEEN GRILLES. SEAL' BLADE MANUAL VOLUME DAMPER W OF NEyV G. eF y0 GRILLE REGISTER , DIFFUSER SCHEDULE oQ ""A SUPPLY AIR DUCT 6» 2A'NGLEIOR Q NECK FRAME MANUFACTURER & 6" r w TAG SERVICE CFM SIZE TYPE PATTERN DAMPER MATERIAL FINISH MODEL NO. REMARKS UNISTRUT y�F O 065526 RG-1 RETURN -- -- NOTE 3 -- NO STEEL OFF—WHITE METALAIRE CC5 1 ,2,3 A90pESSt0NP� VOLUME DAMPER TWO SHEET METAL ROOF 12/22/2022 WTG TRANSF SEE SEE NOTE NO STEEL NOTE 5 TITUS 350 RL 1 ,3,4,5 SELF TAPPING JOIST —1 ER PLANS PLANS 3 SCREWS REVISIONS: NOTES: I 09-26-2022 OL Rx REVIEW#1 1. MODEL NUMBERS ARE METALAIRE UNLESS OTHERWISE NOTED. ROUND RECTANGULAR 09-27-2022 OL RX REVIEW#2 2. PROVIDE TRANSITION TO DIFFUSER WHERE REQUIRED. DUCTWORK DUCTWORK 3. FRAME TYPE TO MATCH CEILING CONSTRUCTION, COORDINATE WITH ARCHITECTURAL PLANS. ROUND 09-27-2022 OL Rx REVIEW#3 4. BLADES SHALL BE PARALLEL TO LONG DIMENSION. CONICAL TAP BRANCH 5. PAINT WTG PT11 (SEAPORT BLUE). CONFIRM COLOR WITH ARCHITECT PRIOR TO CONSTRUCTION. DUCT SUPPORT PARALLEL TO TRUSSES 10-03-2022 PL POST MAIN SUPPLY 12-23-2022 BID/PERMIT SET DUCT (OR ----- INSULATED SUPPLY AIR SUB-MAIN) rl� j TO a1771 TRUNK DUCT - REFER - SPIN-IN TO PLAN -------- INSUSPIN-IN TWO SHEET METAL ROOF INSULATED RIGID R/D=1.0 (MIN) FITTING WITH MANUAL SELF TAPPING JOIST METAL DUCT DAMPER AND ACCESSIBLE SCREWS AND ELBOW I DRAW-BAND CLAMP - - INDICATING HANDLE - TYPICAL EACH END \ TYPICAL MAIN SUPPLY DRAWING BY: CJS DUCTAI CHECKED BY: BC EACH END INSULATED SUB-MAIN INSULATED / FLEX DUCT I DRAW-TYPICABAND CLAMP ) ROUND RECTANGULAR FLEX DUCT / MAX OFFSET ALLOWABLE: DUCTWORK DUCTWORK DATE: 09-22-2022 2-INCHES PER FOOT OF RECTANGULAR FLEXIBLE DUCT LENGTH TO ROUND SIDE DUCT DUCT SUPPORT PERPENDICULAR TO TRUSSES JOB NUMBER: 022139 INSULATE TOP OF DIFFUSER (MAY TAKE-OFF BE OMITTED WHERE CEILING MAX OFFSET ALLOWABLE: TITLE: CAVITY IS USED AS A RETURN 2-INCHES PER FOOT OF 18 GAUGE MECHANICAL PLAN AIR PLENUM - TYPICAL FLEXIBLE DUCT LENGTH VOLUME LOCKING DAMPER WITH SCHEDULES & DETAILS "-CEILING AIR DEVICE - CEILING QUADRANT SET 5 DUCT HANGER DETAIL TYPICAL SHEET NUMBER: (TYP. FOR ALL M_2 NOT TO SCALE LONG RUN, SIDE TAP INSTALLATION BOTTOM TAP INSTALLATION SUPPLY/RETURN/ EXHAUST AIR CEILING DIFFUSER/RETURN BRANCH DUCT) NEWYORK ALTERATION WARNING STATEMENT: Mm2 Z 3 GRILLE CONNECTION DETAIL 4 BRANCH TAKE-OFF DETAILS IT ISAVIOLATIONOFTHENEWYORKEDUCATIONLAW,ARTICLE,45,SECTION COMMENTS: ui w 7209 FOR ANY PERSON,UNLESS THE INDIVIDUAL IS ACTING UNDER THE m DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER AN ITEM IN M-2 NOT TO SCALE M-2 NOT TO SCALE ANY WAY, IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED,THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM THEIR SEAL AND THE Lu o NOTATION"ALTERED BY"FOLLOWED BY THEIR SIGNATURE AND THE DATE OF Z SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. Q