HomeMy WebLinkAbout49875-Z �SUFFOL��,Y Town of Southold ou10/12/2023 P.O.Box 1179 Co. 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44645 Date: 10/12/2023 THIS CERTIFIES that the building ACCESSORY ALTERATION Location of Property: 675 Skippers Ln Orient SCTM#: 473889 Sec/Block/Lot: 24.-2-1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/12/2023 pursuant to which Building Permit No. 49875 dated 10/12/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: outdoor shower addition and electric panel and wiring only to an existing accessory building as applied for (no other work done under this permit) The certificate is issued to Orient Realty LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45564 02/03/2022 PLUMBERS CERTIFICATION DATED 12/11/2020 u ne Hicks ut or a Signature _ TOWN OF SOUTHOLD �o�gtlffOt,�cO BUILDING DEPARTMENT H x TOWN CLERK'S OFFICE or SOUTHOLD, NY { � BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49875 Date: 10/12/2023 Permission is hereby granted to: Orient Realty LLC C/O Ivy Crewdson 61-69 Pierrepont St#51 Brooklyn, NY 11201 To: construct alterations to existing accessory garage as applied for per Landmarks approval. Replaces BP #45564 At premises located at: 675 Skippers Ln SCTM #473889 Sec/Block/Lot# 24.-2-1 Pursuant to application dated 10/12/2023 and approved by the Building Inspector. To expire on 4/12/2025. Fees: PERMIT RENEWAL $120.00 Total: $120.00 Building Inspector ��`ogUFFU(,�COGy TOWN OF SOUTHOLD Oma" BUILDING DEPARTMENT TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45564 Date: 12/11/2020 Permission is hereby granted to: Ballve, Marcelo 438 W Wesley Rd Atlanta, GA 30305 To: construct alterations to existing accessory garage as applied for per Landmarks approval. At premises located at: 675 Skippers Ln., Orient SCTM # 473889 Sec/Block/Lot# 24.-2-1 Pursuant to application dated 12/1/2020 and approved by the Building Inspector. To expire on 6/12/2022. Fees: CO -ACCESSORY BUILDING $50.00 ACCESSORY $100.00 Total: $150.00 Bu i ing Inspector pF SO�ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(a--)town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Orient Realty LLC Address: 675 Skippers Ln City:Orient st: NY zip: 11957 Building Permit#: 45564 Section: 24 Block: 2 Lot: 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage X INVENTORY Service 1 ph Heat Duplec Recpt 3 Ceiling Fixtures 2 Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency FixturesTime Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 200A Panel 42 Circuit/ 11 Used Notes: " AS BUILT NO VISUAL DEFECTS " Acc. Garage Wiring Inspector Signature: Date: February 3, 2022 S.Devlin-Cert Electrical Compliance Form sorry Town Hall Annex l�R Telephone(631)765-1802 54375 Main Road "' Fax(631)765-9502 P.O.Box 1179 %�► :., '� Southold,NY 11971-0959 Q{�COU��'C,,�a , 11 DD BUILDING DEPARTMENT I '1 TOWN OF SOUTHOLD Ij OCT 1 1 2023 "T BUr LDTNG DEPT. T0117%, CERT.IF-ICAT-IO-N Date: a 1 j lao z o Building Permit No.-.q Owner: ®_ n en"t A&d ` y LL C (Please print) Plumber: Pre ►= � K-1 tl� � I (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (Plumbers Signatur Sworn to or me this Richard D.Noncamow day o Gly 20c� Notary Public, obli State tate of 08W Y� / AIS►ComQmi i �irffes June 2f� No Public, "l. I County, SOUTyo� '� # # F%OUTHOLD-BUILDIN DEPT. OWN O `ycou►m,�F'` 765-1802 INSPECTION ' [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [r ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]-- FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: � - L --o DATE INSPECTOR SOGTyO� -- �� # # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ XROUH PLBG. FOUNDATION 2ND [ ATION/CAULKING FRAMING /STRAPPING [ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATI N [ ] PRE C/O [ ]' RENTAL REMARKS: IIfD) R RVM4 NWMAII 15 yr r l DATE INSPECTOR a mage 0 logo AAR h *� J • Ff + _ 4 7 61 1 SOP1 1 r 40 Q F - i f' r w .OL Z 1. O a I I — O 6755 Peers Orient 30Mar23 - (GARAGE) 1 1 i ij �� r ^ Y Jr f 7• HOT TUB �' r •+�� M ti � 1 f 1 ' ! .....—.7— 6755kippers -- • 2 rient [{ t U oMar23 qA (GARAGE L— - . i • s if • , y tet•, f. 1A � r,i ... ^ 1, 1 . • -�• > Or •� � : {�'� moi!'y4,}P, �``�' �� �t .� �' , + •`, • i t t 4 W 675Skippers Orient f� c_� n In a r a o w x (D 0a t Able" I It e Y >. e 675 SKIPPERS LANE ORIENT HPC 25MAY23 PRE-SUBMISISON CONFERENCE PETER MARREN AIA LEED AP A,ml . t ENLARGED VIEW EXISTING GAP 7" INSTALL 1/8" ROUND = STAINLESS STEEL CABLE MOUNTING WITH �THRU-POST FITTINGS USING CLASSIC BUTTON ASSEMBLY f JUN 2 U 2023 TOWN OF SOUTHOLD HISTORIC PRESERVATION COMMISSION �� 3- 5 r_ • 4 .`c �.' ..� �'� .ice• � ` ' 'moi- a;, ,•� •._ -K.- ,.r,��r�'-5:�,' ,' t n �i L is A6 i r JL t i.`^ • • • e • o i� PLLTIYMING • e ' A • . � I� lett ►" _� ' ' ice.' /� EWA RAW]= - - e 4 . 1 �V-5' S.^t. � Cf�'k �s—� �� 44}�'dl.•1'.r_-pS, TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees r C.O.Application Flood Permit Examined ,20 ` i ) % i-� 1 Single&Separate 1 fj Truss Identification Form DEC 2020 .:: .; Storm-Water Assessment Form IP �,-. Contact: Approved 20 ' a ;. `✓� Mail to: Elizabeth Rexrode Disapproved a/c Rexrode Chirigos Architects Phone: 212 387 7980 Expiration 20 Building Inspector APPLICATION FOR BUILDING PERMIT Date November 30 20g_ INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. "e4fap nt Aorn ame-i tx=Toration) Elizabeth Rexrode, Rexrode Chirigos Architects 10 a 23rd street,NY, NY 10010 (Mailing address of applicant) State whether applicant is owner,lessee, agent,architect, engineer,general contractor, electrician,plumber or builder Architect Name of owner of premises Orient Realty LLC (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer Ivy Crewdson, member (Name and title of corporate officer) Builders License No. Mc Mahon Bros Renovation &Restoration limited Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 675 Skippers Lane Orient Village House Number Street Hamlet County Tax Map No. 1000 Section 24 Block 2 Lot 1 Subdivision - Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy garage b. Intended use and occupancy_ _ garage 3. Nature of work(check which applicable):New Building Addition Alteration Repair x Removal Demolition Other Work (Description) 4. Estimated Cost $20,000 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor n/a If garage, number of cars 2 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. n/a 7. Dimensions of existing structures,if any: Front 18.4' Rear 18.3' Depth 20.2' Height 15' Number of Stories 1 Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front 104.66' Rear 103.14' Depth 135.22' /133.33' 10. Date of Purchase August 13,2020 Name of Former Owner Marcelo Ismael Ballve&Sara Silvina Chavarri Ballve 11. Zone or use district in which premises are situated Orient Village 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO x 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO X 61-69 Pierrepont#5 1, 14.Names of Owner of premises orient Realty l_l_c Address Brooklyn,NY 11201 Phone No. 917 337 9027 Name of Architect Rexrode Chingos Architects Address 10 E23rd st,NY, NY 10010 Phone No 212 387 7980 Name of Contractor Dennis McMahon Address 133 central Ave. Phone No. 917 921 6984 Greenport,NY 11944 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO x *IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES x NO *IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES NO_x * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF h� 1L Elizabeth Rexrode being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Architect (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be p o ed in the manner set forth in the application filed therewith. Swo to before me . `f day 20 Tdtary Publ' Signature of Applicant DAVID M ZIDEKAR NOTARY PUBLIC-STATE OF NEW YORK No.01 Z16394330 Qualified.in New York County MY Commission Expires 07-01.2023 ,lr - our Unigz, s.0 yQc,� Ink Edward Webb,Chairperson �� 610 Town Hall Annex Anne Surchin,Vice Chair SOUTHOLD ' 54375 Route 25 Robert Harper `OUVO K PO Box 1179 ;., z Southold NY 11971 Joseph McCarthy N Founded �nr•� g Mariella Ostroski o , '�0 ��" Fax(631)765-9502 Tracey Dwyer,Administrative Assistant 9'� o�� Telephone: (631)765-1802 p� RFSERVAfO' O www.southoldtownny.gov Town of Southold Historic Preservation Commission October 29,2020 RESOLUTION #10.29.20.2 Certificate of Appropriateness RE: 675 Skippers Lane,Orient,NY,SCTM# 1000-24.-2-1 Owner: Orient Realty LLC RESOLUTION: WHEREAS, 675 Skippers Lane, Orient,NY is on the Town of Southold Registry of Historic Landmarks, and WHEREAS, as set forth in Section 56-7(b)of the Town Law(Landmarks Preservation Code) of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit, and, WHEREAS, the applicants architect Elizabeth Rexrode submitted a proposal outlining the scope of work,which included the construction of a 443 sq. ft. screened porch addition and to construct a 250 sq. ft. rear deck addition and the replacement of windows, doors,roof shingles,cedar siding shingles,porch columns and additional details to the existing single family dwelling as applied for,as well as replacing windows, a door, cedar siding shingles,roof shingles,gutters and downspout to the existing accessory garage as applied for, and, WHEREAS, the architect presented commissioners with an outline of the project during a pre- submission conference on September 29, 2020,and, WHEREAS, a public hearing was held on October 29,2020,where the applicants and their architect submitted final drawings of the scope of work and outlined the project for the commission, and, NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines that the proposed work detailed in the above referenced application meets the criteria for approval under Section 170-8 (A)of the Southold Town Code and, BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness. MOVER: Commissioner Harper SECONDER: Commissioner Ostroski AYES: Surchin,Harper,McCarthy and Ostroski RESULT: Passed Please note that any deviation from the approved plans referenced above may require further review from the commission. Signed: Gf Tracey L.Dwyer,Application Coordinate for the Historic Preservation Commission Date: October 30,2020 Mariella Ostroski,Chairperson our Uni Town Hall Annex Anne Surchin,Vice Chair 4ue tip^ 54375 Route 25 Allan Wexler Z ��w� PO Box 1179 Fabiola Santana Southold,NY 11971 MUTHOLD Tara Cubie ` ^��o� f ' Telephone: (631)765-1809 Jeri Woodhouse = PouMod % A Q kimf@southoldtownny.gov Marina de Conciliis N°9, ��o �• Kim E.Fuentes,Coordinator R�5'ERVATION Town of Southold Historic Preservation Commission Certificate of Appropriateness , JUN 2 7 2023 June 22, 2023 Vrl RESOLUTION #6.22.23.5 RE: 675 Skippers Lane, Orient, NY. SCTM# 1000-24-2-1 Owner: Orient Realty, LLC RESOLUTION: WHEREAS, 675 Skippers Lane, Orient,NY, is on the Town of Southold Registry of Historic Landmarks, and WHEREAS, as set forth in Section 56-7(b) of the Town Law(Landmarks Preservation Code)of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit, and, WHEREAS, on March 20, 2023,the applicant's representative,Peter Marren, submitted a proposal to legalize an as-built hot tub on residential property; and WHEREAS, the Commission determined, during pre-submission conferences,that improvements including a Raised Shingled Terrace and the Shielding for generator and mechanics upon this residential property were inconsistent with previously approved Certificate of Appropriateness, Resolution#03.10.21.1 dated March 10, 2021; and WHEREAS, the Commission determined that an outdoor shower is also"as-built" and will require approval; and WHEREAS, the applicant's representative presented Commissioners with Architectural Plans and photographs, consisting of a Raised Shingled Terrace/Balcony attached to the single family dwelling, 4 feet high mahogany fence surrounding utility structures, an outdoor shower, as well as the subject of this application,the hot tub; during a public hearing on June 22, 2023; and WHEREAS, the applicant shall submit to the Commissioners photographs of the finished improvements upon completion; and Certificate of Appropriateness, HPC, Orient Realty, SCTM No. 1000-24-2-1 Page 2 WHEREAS, the Commissioners may conduct a site inspection of subject premises once improvements are completed; and RAISED SHINGLED TERRACE/BALCONY: NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines that the photograph of Raised Shingled Terrace/Balcony,Page A.1, submitted by Peter Marren,AIA, dated May 25, 2023,meets the criteria for approval under Section 170-8 (A)of the Southold Town Code; and BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies; and BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the commission. Motion made by Commissioner Ostroski Motion seconded by; Commissioner Surchin VOTES: AYES: Commissioners Ostroski, Surchin, Wexler and Santana,Woodhouse and de Conciliis. (6-0) RESULT: Passed WOOD MAHOGANY FENCE SHIELDING MECHANICAL EQUIPMENT: NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines that the 4 feet high Solid Mahogany Boards surrounding the mechanical equipment to be extended,and panels be spaced 1-1/2 inch apart,meets the criteria for approval under Section 170-8 (A)of the Southold Town Code; and BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies,and conditioned upon the submission of Revised Elevation and Partial Site Plans depicting the aforementioned approved criteria; and BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the commission. Motion made by Commissioner Ostroski Motion seconded by: Commissioner.Surchin VOTES: AYES: Commissioners Ostroski, Surchin, Santana and de Conciliis. NAYS: Commissioner Wexler and Woodhouse. (4-2) RESULT: Passed Certificate of Appropriateness, HPC, Orient Realty, SCTM No. 1000-24-2-1 Page 3 "AS BUILT"HOT TUB AND "AS BUILT"OUTDOOR SHOWER: NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines"as built"hot tub and"as built" outdoor shower as depicted in photographs (Labeled Outdoor Shower#1, Hot Tub#1 thru#3)submitted by the applicant's representative, and received on April 5,2023,meets the criteria for approval under Section 170-8 (A)of the Southold Town Code;and BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies; BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the commission. Motion made by Commissioner Ostroski Motion seconded by: Commissioner Surchin VOTES: AYES: Commissioners Ostroski, Surchin, Wexler and Santana,Woodhouse and de Conciliis. (6-0) RESULT: Passed Please note that any deviation from the approved plans referenced above may require further review from the commission. Signed: Kim E!Fuentes Coordinator for the Historic Preservation Commission Date: June 22,2023 �o��SufFOlKco BUILDING DEPARTMENT- Electrical Inspector Gy TOWN OF SOUTHOLD o z Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 �yfj0 a0`� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a-southoldtownny.Qov— seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: Cross Street: Phone No.: BIdg.Permit#: `v email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YI=S❑NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect[]service Reconnect❑Underground❑Overhead #Underground Laterals 1 72 7 H Frame 0 Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION ;�'�!✓ (� �I �1 ' a � �-�� f pF SOUryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G.c� • Q Southold,NY 11971-0959 Q a �yOOUNT`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD September 27, 2023 To Whom It May Concern: RE: Orient Realty LLC C/O Ivy Crewdson 61-69 Pierrepont Street, #51 Brooklyn, New York 11201 Please see the attached inspection slip for BP #45564 for alterations to the accessory garage. The renewal fee for this Building Permit is $120.00. Best Regards, Southold Town Building Dept. REXRODE CHIRIGOS ARCHITECTS r 30 November 2020 Connie Bunch Town of Southold Building Department 54375 Main Street Southold, NY 11971 re: 675 Skipper Lane, Orient NY Tax map 1000-24-02-1 via: Fed ex-tracking # 21 ices- Is 01 YO. (p 2.3 o' Connie, Enclosed r lacemen ch k in the ount f$1,206. for ermit fe re ted t ermit#45453 Oit R It LLC, 5 Skippe ane, Or . /"�Rl�easenfirm receipt and call me when the permit is ready. - We will arrange for the General Contractor to pick up. Enclosed check in the amount of$298.67 to cover$150 Application fee and cost of permit for garage ($.40/sq ft x 372 square feet= $148.67). --- - _ Enclosed Building Permit Application for Garage as separate structure Enclosed Four(4) sets of Signed and Sealed.Drawings for the-garage. I would appreciate if you cancall to confirm receipt since our previous check was lost. Thank you for all of your assistance-'" With regard, Elizabeth Rexrode i 10 East 23rd Street, 6th floor New York NY 10010 T 212 387 7980 www.rexrodechirigos.com i 1� APPROED AS NOT D DATE: B.P.# FEE:Iwe c BY:_ NOTIFY BUILDING CEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: ED Q 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE CA D 0 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUC70N MUST BE COMPLETE FOF ,;.0. ALL CONSTRUCTI;N Sr,ALL MEET THE L/J! ILLJJJ ILJJ ILJ'JL{1 IIh_ L/rL,l\�ILJnV�II REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF I oy Ie NEW YORK STATE & TOWN CODES _� I AS REQUIF'ED AND CONDITIONS OF -- ' ' BOARD _401 +9Li�T`O� I }JSTEES 0 CCUPANCY OR ARCHITECT: USE IS UlgLAWFUL REXRODE CH I RIGOS ARCHITECTS WITHOUT CERTIFICATE OF OCCUPANCY 10 EAST 23RD STREET, 7TH FLOOR NEW YORK, NY 10010 ELECTRICAL T E L: 212 387 7980 INSPECTION REQUIRPED All exterior lighting Installed, replaced or DRAWING LIST repaired shall conform to Chapter 172 of the Town Code ARCHITECTURAL A-000.00 TITLE SHEET S-000.00 GARAGE SURVEY A-010.00 GARAGE SITE PLAN A-020.00 GENERAL NOTES A-050.00 GARAGE PLANS A-200.00 GARAGE EXTERIOR ELEVATIONS N-W A-201 .00 GARAGE EXTERIOR ELEVATIONS S-E A-300.00 GARAGE EXTERIOR DETAILS & SCHEDULES A-301 .00 DOOR & WINDOW TYPES, DETAILS .22%61 DEIDARTMENT OF BUILDINGS 11 . 30 , 2020 RENOVATION OF: CREWDSON y<„ ,aj+ 3 { `I ? ' REIDa, ••ya' s by r '•1 d j.: =6 _ ° n S E N V f r 1 r•i "{ kt +Y'I" •i ,Ni''x >sa•+ i f .ti2 4a 1' 7" _ p n i � 1 n� -7 - `s= 1e � �1. d s'' k• 2 ice,' x�+ e1 I% J 1 ..T '-xr eT. _ Y. P.,�,f4' a, t•t:. a i'' v' r. t-i'� -d'dx - "61e. sYr #, i° p:: �F,e - yif: 3 s, r, cp TOWN US LO a; ���" _ TRUSTEE T COVERAGE) =��� r';�� -; V RAGE :,v alo•' >_��� >'i 'da ' + t vn Y }} F 3(4 [�L\� �/ s 75SKIPPERS of - - A N Y +a saE „ , „ P, , T 7 Y aq `.h t tx. t �t 1 y�a e s.' .fir= i r u .�� .PEr� :a •t_, 7, r' 4 - .g ,tR =i EXI IN LOT COVERAGE 0 ED t �'F'• ST G C E PR POS LOT COVERAGE ..r { ` 1 p 1' i �. 1 — , .t 0 R S R ��. 1 ,z - L T A EA 13 817 FT LOT AREA— 13 817 S > Q Q ORIENT NT 1 I �i• N �. 9 { 3 57 j�P. f 9 w.• } a` :•�- '',', as :S> EXISTING HOUSE— 302 S FT EXISTING HOUSE 1 302 S t` - S Q 0 FT i xw „ �a1 .fir a) s p i`' max: WN—OF Il°i' yi'£' F. EXISTING GARAGE 373 S FT EXISTING GARAGE 73 ,i'' b 3 S FT Q :Y� of%' ''3"' ..t r „ }' sX � t nr jd"� r'd t� - _ r= '.j i P f b a _ .R' ¢r- I � EXISTING PORCHES 303 S FT EXISTING PORCHES— 3 �°. .�- ST G PO ES— 30 S °i. Q f E' (> L � i�' L ��vr'�� Tyr, - afi DRIVEWAY 578 S - rL EXISTING DR FT PROPOSED P RC 4 Q 0 HES 43 SO �� -•� � {3° �' ARCHITECT: Q i' TECT: FT 1. i" , •i s= si! 45' 1 a s - ` t-`- f. ^x' a' y ' i-., f Jb Pte' :r .'U _ 1 :.'dye -a r I t EXISTING SIDEWALK— 89 S FC — - EX GSD PROPOSED TERRACE— 50 :�':�• ,{ .� Q T C 2 S {' .� j' — :�DOD 2 4--0 — t- =y,n. 2 D — `r "la 'r 64 ,._; TOTALS Fr= 2 5 S FT OTA 6 TOTAL FT 2 7 S Q 1 FT 4 Q 0 1 3 . .a 1 J {{ a r: s 3' {x CASE — 0. REXRODE R D EC HIRIG OS r ARC H ITEC '3 TS i' a. 1,h r 19.14% 2,645/13,817= 2 671 13 817 19. . 339' %S'` a . 3 ff .j e ,:•1` y +( J 5• _ 'SEPTEM i' :a qP I , `i i h yJ a i I hi Y 't+ l h f p .f fi 3 4 ,1« .{ t 1 , 4. L - .t4 . f _ r,; -t a rr /� Ta -x• t= ,f -:OCTR., I � n V TQII/Y .'71�4J3 C 'C VER AG E a ':Tr, r•� s1 r .i• v� ;'•r. k� i 1 r, t c � 3_ 1 J - 0 A 1 EST 23 � RD ST 6TH FL r y F a OOR }. t t` fl :n RI e' •r f t a .y. p a. d _ NE = W YO R K NE W YO RK 10 010 p _ -_ .et 1 b� - , .f y 3' 'J f •-p _ ;°>,' T 212 38 7 ,.. 7980 F2 •, y 12 260 s 2794 i �a ? 4� a el - at• "5n t of .r., ,j. +i- - °3 "�w• .a '*dei t J� ,;rrwY S' 33 I 1, p, - i , P 1 L.v 9 �z }' a t: >c,lY "T. 5' a-, l 3• S a� z , s it x f` Y° , _ 1 i N� S R T UCTURA I L ENGINEER: i 1"+ 3 r' . 's• 1 P _ E' r ri q s =n. DWELL`F i' � E n> i t a? 3 3 ,r; rf" - .t{- +Vi P '1 I 'G ^� .ER. r- b V 50 1 .�W. EVAN AK ,I s>� �'. S E LRAD •'Jw9 -�'�' - A a °ti y�,,w I h t•, l ,Y. ,fi v I i i ;� a B LD .Y, 1 I � t E °OF. L A WE L D E t t •Y ,j. tl• f7 yr `1 Iv, i _ { h 8' 9 , 4 M 4° i` { t• 5 , f 4 ix; S�• 16 JAY ST , F� i a. EET FL 3 , s s , 'r , rt 1 1 , •s' Z P, , a , a� C ,d' N EW YORK,.� IC N .f EW YORK 1001 p T 917 689 X0301 III} � til }.1 f- k`� .5 l• .°l}. ,. '.X`°.-.. Z +`I,.,r' 33pp Y>* P 1' d� t°a i 'i Sn #' q { } ai S E a L 8.3 - > ISSUED T C FOR �1 I' "I �5�ry DATE to Z }•a. 3> 4� i' i °"Lav t y p q a r' 1 z< t' i� w a - DOB 1 1 .3 0.2020 :X 5 A 1 d is .. •`G i x - 4 - 7'e m } d". 3 `] a i !�r > 3 .p rt rk x +r,t t i 9 r a.. L G _ - WEL IN s` ( 9 I� { v#3 3 I s i' b { s, t est" ^i 2 UNKNOWN # P - G. . :Y �5 b 4 I. ,.. I' ° 4''S• °Sa" ,i J' F' 9 N ,p J 7 I i a 1' F• mo/i�,�, 1 �7a' f" e+� ;i , x > EL 7. , - 9. P b' , :r a a° j :B a +\ I' ° i p i 1 I + 6 +4 , r 'T- >,f c •p• d, S , x,. :\ I - H - Y r 4 l 5 �P ? , , DW L , E �. 9 ",. 1 NCy• WE a L L � •1' ,ti, 0 4 - ie` 9 ,r WE F LL , EL f' �j a: t , °�t' -OVER i � R 5 0 � 0 I �•,, I p: > �. �r t '•1" Yi u• +� 3 ,a r<c 3, 'I 4 x+ .y. 'r s• i> Y r� a: s Y;+ r. f ram' c\ e, O 3 =a A,. ,y Y' Y t IF.ae a a. �r ts•'.; y. S IS t� 1 't , 7 }` - ?47 - J r, NOTE.• S YVAL 'er ya, a,r _ 3, S e :d •lay'^ z { a { esr t. Y a{ a4 A �3 555 TO 8E - r•ll b i1 3P^ lx NEO. �. N v+ T - 71NG WELL /N B BA EX/S BASEMENT TO BE � P a- ,p p i` .�n MOVED - o. RE �' G 4 y ,tea ti_1 O _ r, Itv I ^4 t 'z i . S A• f Q C Y' - °9 ,3 4 4' l'S ,k . 1t , T`R E ry D ti. z .a' E t, i ti ry r° ,i• +x :a j 1 1 'ry _1 7 '6 N A S ry A -J X y S' , E IS TING ? 8 a `a Y? fi 'r F, 1.0 , I 1 R ST TE YV T , E � - a' lL f y tl i .,.t s{' / ,T l 'sT 3 -8t, a Y� r ` ms d f 7 'S .� wy s )a �4 f `V S Y' - 7 a i, 1: r' 'Q x r '3 4 R C a, '1 • F ^� 'S r' S - / 'F 1' t / o C I i- t i REE. '3 7; r , AK,y yy '1+ d � y "1 S' "S r ;n .tr P `a• i'`,s 3 9 + I yy O' V + r14� 1 N EXISTI G P r qC °z W l E1�N: �Q µ,e J' 2 t, �X1STfNG _ r' BASE EN �j 32" , PORCH To r �y , Q o y- r' r ;T S a i s� EMAtN ; EL L „ r S= 4 �~ p KC '4 R T 9 I, o EL 5.8 _ p _ {r. +14 /f '�5 z r•I: I' r4 �• +J .t� S - i. { b ds> a I` � EL 9 � �- R _ �x 9 - KEY e m , -a � •le o, C - A x' A ti k O - r•r;'r • R A f �, Y d' .� '•i EBR s a I , '1 4 S {, 'A a iY& .w T. }} ra' k° Mme:` .'p t .15 Y' JJ V Y` Q 4 e J S WELL ��� F , C" F, 1� n r? - s 4 5 D' 1 t I t• 4, i' 3' N , s C� TE 0 . ST HOLE 6 : 9 - `r � 4 0` V 4 , ,Y 3' ;fir r S o _ 4 � d p 4 STA 'r. KE 0 1 �° �^i ff ..• O Y £_ t a J <. '1 k~ i' r„ _ PIPE Sr l 50 N �a - 1 Y yAy /,1Q�j[Y, ,C, i ^4 5 `, 6 1 I r+ i. � � EL�..1 NC�r s �-s" e.+ f tl ,n i .,F x r� � i �y..' ® M , `t� ONUMENT '�" s r,2_ .f= «I> - dr� 1^ Y v S! '1 yy alb•�,t _ f P d`, t,i e. / Via' �y �, S M°a i VO .�: c lel COVER 1 z 4> L7 SS "Y .4. - WETLAND r Fa' FLAG �� I J,4� S e., :a } F h r. �;ka r 1• 3: f 1 .r+ s p� � tt Ana" ate. ^k. I aN E' d. � a' P E _ t POLE i O - `ir ' y „ r 3,. •i'�a •3' { a J - r f'. 0 v tiT` - V �1 _ Cf� l _ .X< HYDRANT A' - .Lr t' W f' kt V H '-t,rF�- �"�•�.•',, -1.-, ^Y t + W' �1 f: 3 , t - t P <_ ,J • M1Y O .3° 1• , x Y N ;` DRAW + �� DRAWING i. ;r TITLE c Q 3 •Y ee , a' a ;JI '1 t� t r .� s. C ATIDN G 'S' E EV S REFERENCED >,., 't � s L CED TO , NA 88 °r ,/� 'R. t i. V �F A i �' �5: i 5 '�. 1 `� G 'S b• { 'Y 4 `f i°" rv1 3 'ls 1 E K �S �. - .g T r O� 2 •AF l: 1 r^ e( 4 V 1 a L� ,V 0 i f f mlllar w �a I am !th the STANDARDS FOR APPROVA AND 0 C fir'• -- 4 L C NSTRU 7)ON OF <�y T 'o s A r• a 7. •b r Tl UR ePa: S BS FACE SEWAGE � �'r` ,rb U E GE D1 PO �, r S SAL SYSTEMS 1 TE S FOR SINGLE FAMILY I L RESIDENCES , C S H�'�. P, 9 7 p t i s:. 7S a3 .. R A E SURD !I, abide EY and w b! b the condi tons se or 1 t forth therein and on the ', t h erml o �aY" t t .� r a 1 4 ruc .- const The location t c on of wells Is and cesspools , e s ools shown hereon eon are r P h from a t - s observations b fled sertroflons n •; ador from d ,"�' , ota obtained from r fr others. 'zt >r'- a I - 'Y 1 ris i+ M!. 4 p' I` r a k' >q T d - I'a i 9 t f r' >6 `,{ TJ I� R :`� i i^ ar ANY ALTS ATION R �=r;° 0 AD l D TION TO °„� -�� THIS SURVEY '�r , R /S A V/OLAl10 F N 0 SECTI 7 ON 2090E i THE t' , •f i' :s .'r NEW K STA 7E EDUCVISION A 0 �E TI N L W A EXCEPT AS PER SECTION 9 720 SUB I D 2 • L r z r” � 1 f • � Fk FIC '..� .. .... '' " •, �. .F, '�: '' `•: . ._ .. 4:.. CERTi A710NS HEREON ARE •,�_��`-' � '�,�� �� �'•' VALID FOR THIS MAP AND COPIES THEREOF ONLY/F . 1...•�+, , .. NL SAID ,, ��., b b q 20• X b31 •�'7b .1 f',�i 5: 17: MAP OR CSURVEYOR _9 �s OP/ES BEAR THE IMPRESSED ��� PRESSED SEAL 0 E '° F TI-1 IIpp `'h°° WHOSE /G rAlr•1 n S NATURE E "'�V �� �� 3•' A. �: ; Mfr; - � a .� vy d. - f+, - r O� C- F' v 1. APPEARS "{, ,�1 PE RS HEREON �= P t" °a` L ;` .i. 3�• x1. Irl. ^, -! 3©° 7R • AVELE T ,r �H E xs. a:•, T 'ye +6' r t , 3 « i t p U , �5 rH0 0 LD' o t r'> a.. Ya F Js•• ds... T _a 1. 1 `n .X , aI '.4q" •P'^fid+: ��77� .y +Y r �x 1 SURVEY S - 0100 . 0010 1" = 2C-0- DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS RENOVATION OF: CREWDSON RESIDENCE SKIPPERS LANE 675 SKIPPERS LANE ORIENT, NY 11957 ARCHITECT: EX'G CONCRETE SIDEWALK EX'G 135.25' o WELL REXRODE CHIRIGOS ARCHITECTS NEW UNDERGROUND ! ELECTRIC FENCE I 10 EAST 23RD ST., 6TH FLOOR � Y NEW YORK, NEW YORK 10010 I o I o T 212 387 7980 F 212 260 2794 Lu N cr-, U I N 0 I U STRUCTURAL ENGINEER: cp o I w C-� 40.4' I 32.1' I EVAN AKSELRAD EX'G ASPHALT I DRIVEWAY 1 16 JAY STREET, FL3 SLOPE SLOPE NEW YORK, NEW YORK 10013 I EX'G PORCH T 917 689 100301 I SLOPE TO REMAIN 18.4' 5'7 ISSUED TO FOR DATE 0 0 35' FRONT YARD SETBACK DOB 11 .30.2020 E SLOP -`v SLOPE f� cv z O F1Y N ! uI 1 1 SLOPE SLOPE Cif I \� z cif 5.3' , in in NEW CONDENSERS I & GENERATOR I I ! ! 32 2' EX'G SPLIT I RAIL FENCE 1 \ EX'G SLOPE SLOPE I I I 1 \ FLAGPOLE -o NEW SCREENED IN PORCH ADDITION J I I I I I I I I NEW UNDERGROUND qA \ NEW BLUESTONE PAVING—/ 0 sEl) I ELECTRIC FENCE I app F \ 10' SIDE YARD SETBACK I \ 1 EX'G SPLIT RAIL FENCE DRAWING TITLE � �- - - - - - - - - - - - - - - -� GARAGE SITE N 64'45'40'W \ 133.33' P LAN OYSTER PONDS HISTORICAL SOCIETY 1 SITE PLAN SCALE: 1/8" = 1'-0" 00 W A- 0 10 . o DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS GENERAL NOTES: BUILDING CODE NOTES: SYMBOLS: ABBREVIATIONS: RENOVATION OF: 1. THE CONSTRUCTION MANAGER/GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING 1. ALL CONSTRUCTION WORK SHALL BE DONE IN ACCORDANCE WITH THE ———— EX'G CONSTRUCTION TO BE REMOVED CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK, AND SHALL REPORT ANY REQUIREMENTS OF THE FOLLOWING: - —— —- ACOUSTICAL ACOUS. INSULATION INSUL. DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT. ADJACENT ADJ. MAXIMUM MAX. • 2020 RESIDENTIAL CODE RC CODE OF NEW YORK STATE / EX G CONSTRUCTION TO REMAIN AIR CONDITIONING A C MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER ( ) MECHANICAL M L. 2• • 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK ALUMINUM ALUM. METAL MTCREW DSO N CONSTRUCTION OF ANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WERE STATE (ECCCNYS) NEW PARTITION APPROXIMATE APPROX. INDICATED IN THE DRAWINGS. MINIMUM MIN. • 2020 EXISTING BUILDING CODE OF NEW YORK STATE ARCHITECTURAL ARCH. MISCELLANEOUS MISC. • SOUTHOLD TOWN CODE N ` r— BREAK LINE RESIDENCE 3, THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH BLOCKING BLK G MOUNTED MTD. REQUIREMENTS OF LOCAL AUTHORITIES. CEILING CLG. NOT APPLICABLE N.A. 2. PER RC OF NEW YORK STATE R102.7.1 ADDITIONS, ALTERATIONS OR REPAIRS TO — — — — OBJECT HIDDEN OR ABOVE CENTER LINE CL. ON CENTER O.C. 4. ALL DIMENSIONS ARE FROM FINISHED WALLS AND PARTITIONS UNLESS OTHERWISE ANY STRUCTURE SHALL CONFORM TO THE REQUIREMENTS FOR A NEW STRUCTURE c 8 CLOSET CLO. OPENING OPN'G INDICATED. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS, WALLS WITHOUT REQUIRING THE EXISTING STRUCTURE TO COMPLY WITH THE REQUIREMENTS OF A405 DETAIL SYMBOL COLUMN COL. OPPOSITE OPP. THE CODE. ADDITIONS, ALTERATIONS, RE'AIRS AND RELOCATIONS SHALL NOT CAUSE AN SHOWN TI 'ALIGN' SHALL BE FINISHED FLUSH AND SMOOTH WITH EXISTING WORK. AFTER CONCRETE CONS. PAINTED PTD. 6 75 SKIPPERS LANE EXISTING STRUCTURE TO BECOME UNSAFE OR ADVERSELY AFFECT THE PERFORMANCE OF QUANTITY QTY. THE PARTITION WALLS HAVE BEEN LAID OUT THE ARCHITECT IS TO BE NOTIFIED SO THAT THE BUILDING. CONSTRUCTION CONST. WORK MAY BE INSPECTED AND APPROVED FOR CONFORMANCE WITH DESIGN BEFORE 4< 2 t ELEVATION/ SECTION SYMBOL CONTINUOUS CONT. RECESSED REC. PROCEEDING WITH ADDITIONAL CONSTRUCTION. A3oo DETAIL DTL. REQUIRED REQ'D 3. ALL ELECTRICAL WORK TO CONFORM TO LOCAL, STATE, AND N.E.C. AND 3 UNDERWRITERS REQUIREMENTS. REVISE DOOR DIMENSION DIM. REVISE/REVISION REV. ORIENT, N Y 11957 5. ALL WORK TO BE COORDINATED BY GENERAL CONTRACTOR UNLESS OTHERWISE NOTED. os WORKROOM ROOM IDENTIFICATION ROUGH OPENING R.O. ANY SUBSTITUTE IN SPECIFICATIONS MUST BE SUBMITTED TO THE ARCHITECT FOR 4. ALL PLUMBING TO CONFORM TO LOCAL AND STATE CODES AND HEALTH DRAWING DWG. SCHEDULE R.O. APPROVAL. SHOULD THE CONTRACTOR FIND ANY DISCREPANCIES, OMISSIONS, DEPARTMENT REQUIREMENTS. DOOR IDENTIFICATION ELECTRIC/ELECTRICAL ELEC. AMBIGUITIES, OR CONFLICTS IN ANY OF THE CONSTRUCTION DRAWINGS, OR BE IN DOUBT XX EQUAL EQ. SECTION SECT. AS TO THEIR MEANING, THEY MUST BRING THE QUESTION TO THE ATTENTION OF THE 5. ALL FRAMING TO CONFORM TO THE INTERNATIONAL BUILDING CODE, FOR HIGH WIND EXISTING EX'G SHEET SHT. ARCHITECT: ARCHITECT PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL REVIEW THE ZONE 3, 120 MPH, 3 SECOND GUST. SITE IS EXPOSURE B. ALL FRAMING HARDWARE TO EXTERIOR EXT. SIMILAR SIM, QUESTION AND WHERE INFORMATION SOUGHT IS NOT CLEARLY INDICATED OR SPECIFIED, BE SIMPSON STRONG-TIE WITH A CONTINUOUS LOAD TRANSFER PATH FROM THE RAFTERS FINISH FIN SQUARE FOOT S.F. WILL ISSUE A CLARIFYING ADDENDUM. NEITHER THE OWNER NOR THE ARCHITECT WILL BE TO THE FOUNDATION. SHEATHING MUST BE NAILED TO TOP PLATE, OTHER PLATES, ALL 5 PARTITION TYPE FINISH FLOOR FIN. FL. STEEL STL. REXRODE CHIRIGOS ARCHITECTS RESPONSIBLE FOR VERBAL INSTRUCTIONS. STUDS AND ALL HEADERS, ROOF RAFTERS TO BE CLIPPED ACROSS THE PLATE TO THE FLOOR FL. TO BE DETERMINED T.B.D. STUD FOOT/FEET FT. TYPICAL TYP. 6. WRITTEN REQUESTS MUST BE SUBMITTED FOR ANY PROPOSED CHANGES IN THE SCOPE GROUND FAULT INTER. GFI. VERIFY IN FIELD V.I F. OF THE WORK BY THE GENERAL CONTRACTOR TO THE CLIENT AND ARCHITECT BEFORE 6. REQUIRED INSPECTIONS: SD SMOKE/ CARBON MONOXIDE GYPSUM WALLBOARD GWB WWITH W/ ANY WORK IS STARTED. SUCH REQUESTS SHALL INDICATE SCOPE OF WORK, COST, AND • FOOTING AND FOUNDATION INSPECTION DETECTOR HEATING, VENT. & A/C HVAC WITHOUT W/0 POSSIBLE DELAYS TO THE PROJECT. • FRAMING AND ROUGH-IN INSPECTION WOOD W • 10 EAST 23RD ST., 6TH FLOOR • PLUMBING ROUGH-IN INSPECTION 7. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL • GAS ROUGH-IN INSPECTION NEW YORK, NEW YORK 10010 CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION AREA AND ALL • MECHANICAL ROUGH-IN INSPECTION T 212 387 7980 F 212 260 2794 COMMON SPACES LEADING TO AND FROM THE CONSTRUCTION AREA. GENERAL • ELECTRICAL INSPECTION CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED • FINAL INSPECTION BY OR DURING THE EXECUTION. 7. THE CONTRACTOR SHALL NOTIFY THE CODE OFFICIAL WHEN WORK IS READY FOR A. THE DRAWINGS MAY NOT SHOW ALL ITEMS OR OBJECTS EXISTING AT THE SITE. INSPECTION, AND SHALL PROVIDE ACCESS TO AND MEANS FOR INSPECTIONS. STRUCTURAL ENGINEER: THE CONTRACTOR MUST VERIFY AT THE SITE ALL OBJECTS TO BE PRESERVED AND REPORT TO THE ARCHITECT ANY DISCREPANCIES OR QUESTIONABLE ITEMS. B. USE ALL MEANS NECESSARY TO PROTECT EXISTING OBJECTS DESIGNATED TO EVAN AKSELRAD REMAIN, AND IN THE EVENT OF DAMAGE, IMMEDIATELY MAKE ALL REPAIRS AND REPLACEMENTS NECESSARY TO THE APPROVAL OF THE ARCHITECT AT NO ADDITIONAL EXPENSE TO THE OWNER. C. PRIOR TO COMMENCEMENT, CAREFULLY INSPECT THE ENTIRE SITE AND ALL OBJECTS DESIGNATED TO BE REMOVED AND TO BE PRESERVED, AS WELL AS ALL EXISTING 16 JAY STREET, FL 3 UTILITIES. THE GENERAL CONTRACTOR SHALL REMOVE, REROUTEAND/OR CAP OFF ALL UNUSED UTILITIES AFTER CHECKING WITH THE ARCHITECT. THESE ITEMS SHALL BE NEW YORK, NEW YORK 10013 CAPPED OFF WITHIN EXISTING WALLS OR FLOORS. T 917 689 0301 8. PARTITIONS: A. ALL OUTSIDE CORNERS AT MASONRY AND DRYWALL PARTITIONS SHALL HAVE METAL CORNER BEADS. TAPE AND SPACKLE SMOOTH WHERE REQUIRED. THREE COAT SPACKLE FINISH MIN. ISSUED TO FOR DATE B. ALL DEFECTIVE PLASTER AND/OR DRYWALL ON ADJACENT EXISTING WALLS SHALL BE CHOPPED OUT AND/OR PATCHED FREE OF IRREGULARITIES AND SHALL MATCH ADJACENT WALLS IN FINISH AND THICKNESS. DOB 11 .30.2020 C. ALIGNMENT OF NEW WALL CONSTRUCTION TO EXISTING WALLS AND COLUMNS SHALL BE DONE IN A MANNER AS TO VISIBLY ELIMINATE THE POINT OF CONTACT OR JOINT OF NEW AND EXISTING MATERIALS. D. WHERE DEMOLITION HAS OCCURED, CONTRACTOR SHALL FILL ALL HOLES, PATCH SMOOTH AND LEVEL ALL REMAINING SURFACES, INCLUDING WALLS, FLOORS AND CEILINGS, SQUARE ALL CORNERS AND PROPERLY PREPARE ALL SURFACES TO RECEIVE FINISHES. 9. CLEAN UP: THE GENERAL CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATION OF MATERIAL AND DEBRIS. PREMISES SHALL BE LEFT BROOM CLEAN AT THE CLOSE OF EVERY WORK DAY. CONTRACTORS MUST PROVIDE THEIR OWN DUMPSTERS. ALL PAINT BRUSHES, ETC. MUST BE CLEANED IN SLOP SINKS LOCATED EITHER IN THE BACK HALLWAYS OR IN THE BASEMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL UNWANTED EQUIPMENT AND DEBRIS AT THE COMPLETION OF CONSTRUCTION. AT THE COMPLETION OF THE WORK, THE GENERAL CONTRACTOR SHALL PERFORM THE FOLLOWING CLEANING: A. CLEAN FIXTURES, EQUIPMENT, FINISH HARDWARE, PAINTED AND DECORATED SURFACES, AND REMOVE MARKS, STAINS, PAINT, DIRT, AND OTHER SOILING RESULTING FROM THE WORK OF THIS CONTRACT. 10. FIRE SAFETY: A. ALL BUILDING MATERIALS STORED AT CONSTRUCTION AREA ARE TO BE SECURED IN A LOCKED AREA WITH ACCESS CONTROLLED BY THE OWNER AND/OR GENERAL CONTRACTOR. B. ALL MATERIAL TO BE STORED IN AN ORDERLY FASHION. C. ALL FLAMMABLE MATERIALS ARE TO BE KEPT TIGHTLY SEALED IN THEIR ORIGINAL CONTAINERS. SUCH MATERIALS SHALL BE KEPT AWAY FROM HEAT OR OPEN FLAMES. D. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE. E. ALL ELECTRICAL POWER IS TO BE SHUT OFF WHERE THERE IS AN EXPOSED CONDUIT. F. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA IS TO BE SHUT OFF AFTER WORKING HOURS. G. GENERAL CONTRACTOR AT ALL TIMES SHALL MAKE SURE THERE IS NO LEAKAGE OF NATURAL GAS IN BUILDING, OR ANY OTHER FLAMMABLE GAS USED IN CONSTRUCTION. H. GENERAL CONTRACTOR SHALL NOT BURN ANY DEBRIS OR MAINTAIN ANY OPEN FLAMES ON THE SITE. PLUMBING NOTES: 1. ALL PLUMBING WORK SHALL BE PERFORMED BY A LICENSED PLUMBER. SEO A� 2. PLUMBER MUST CHECK EXISTING WASTE AND VENT LINES TO BE FREE OF OBSTRUCTION. <61 A. 3. PROVIDE NEW ISOLATION VALVES AND BRANCH LINES FOR HOT AND COLD WATER SUPPLY FOR RENOVATED BATHROOMS AND KITCHEN. ALL NEW COPPER PIPING SHALL BE PROVIDED FROM THE ISOLATION VALVE TO EACH FIXTURE. ALL NEW SHUTOFF VALVES TO f BE PROVIDED AT EACH FIXTURE. ELECTRICAL NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A NY STATE LICENSED ELECTRICIAN AND ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL JURISDICTION SMOKE DETECTOR NOTES: (DWELLING UNITS) DRAWING TITLE 1, SMOKE DETECTORS SHALL BE INSTALLED AS REQUIRED BY R314 SMOKE ALARMS AND HEAT DETECTION GENERAL N 2. DETECTORS SHALL BE EITHER IONIZATION CHAMBER OR PHOTOELECTRIC TYPE. 3, UNITS TO BE APPROVED BY BOARD OF STANDARDS AND APPEALS, ACCEPTED PURSUANT TO RULES AND REGULATIONS PROMULGATED BY THE COMMISSIONER OR LISTED BY AN ACCEPTABLE TESTING LABORATORY, SUCH AS: (a) UNDERWRITER'S LABORATORY, NORTHBROOK, ILLINOIS, MEA LAB.; (b) CANADIAN STANDARD ASSOCIATION, ONTARIO, CANADA, (a) UNDERWRITER'S LAB. OF CANADA, ONTARIO, CANADA, MEA LAB. 4, UNITS SHALL BE INSTALLED IN AREAS DESIGNATED ON PLANS; THEY SHALL BE LOCATED ON OR NEAR THE CEILINGS AND WITHIN 15'-0" OF ANY ROOMS USED FOR SLEEPING PURPOSES; FOR DWELLING UNITS WITH MULTIPLE LEVELS, WHEN ANY LEVEL HAS ONLY ONE MEANS OF EGRESS, UNITS SHALL BE PROVIDED AT ALL LEVELS. 5. SMOKE DETECTORS SHALL BE INSTALLED AS FOLLOWS: a (a/ A - 0204, 00 CEILING MOUNT - CLOSEST EDGE OF UNIT SHALL BE MINIMUM OF 4" FROM ANY WALL. CARBON MONOXIDE ALARM NOTES: DRAWING NUMBER: 1. CARBON MONOXIDE ALARMS SHALL BE INSTALLED AS REQUIRED BY R315-CARBON MONOXIDE ALARMS © REXRODE CHIRIGOS ARCHITECTS RENOVATION OF: CREWDSON RESIDENCE 675 SKIPPERS LANE ORIENT, NY 11957 ARCHITECT: REXRODE CHIRIGOS ARCHITECTS 10 EAST 23RD ST., 6TH FLOOR NEW YORK, NEW YORK 10010 �) T 212 387 7980 F 212 260 2794 STRUCTURAL ENGINEER.. EVAN AKS ELRAD 24 r� REMOVE EX'G A201 G � WINDOWS FOR 301 D NEW 16 JAY STREET, FL3 INSTALL OF NEW WINDOW NEW YORK, NEW YORK 10013 D.S.0 T 917 689 00301 NEW OSE BIB ISSUED TO FOR DATE NEW SINK, MILLWORK �r-1- DOB 1 1 .30.2020 & SHELF J 301 GARAGE REMOVE EX'G 14'-6" DOOR FOR 301 INSTALL OF NEW NEW DOOR EX'G 1,3 RIDGE EX'G A200 301 GARAGE A201 WP BEAM GARAGE DOORS TO REMAIN NEW NEW WALL WINDOW SCONCE / EX'G REMOVE EX'G III - WINDOWS FOR CROSS 301C \ �/ III INSTALL OF NEW BEAMS\ - - - NEW / ROOFLINE ABOVE 301A 3018 PENDANT I / & SWITCHS D.S.(D =REMOVE EX'G NEW WINDOWS WINDOWS FOR INSTALL OF NEW 2,4 A200 0 GARAGE DEMO PLAN 2 GARAGE PLAN �j GARAGE RCP T I�EDA SCALE: 1/4" = 1'-0° SCALE: 1/4" = 1'-0" SCALE: 1/4" - 1'-0" `45 261 DRAWING TITLE GARAGE DEMO P LAN I FLOOR PLAN & REELECTED CEILING PLAN A- 050 . 00 DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS RENOVATION OF: CREWDSON RESIDENCE 675 SKIPPERS LANE RIDGE ORIENT, NY 11957 RIDGE „ EL. 15'-1 1/2" EL. 15 —1 1/2 B.O. BEAM B.O. BEAM ARCHITECT: EL. 14'-6" EL. 14'-6" REXRODE CHIRIGOS ARCHITECTS RE V G RO HINGLES R IN LL OF REMOVE EX'G NEW 10 EAST 23RD ST., 6TH FLOOR CEDAR SHINGLES NEW YORK, NEW YORK 10010 FOR INSTALL OF T 212 387 7980 F 212 260 2794 NEW B.O. BEAM B.O. BEAM _ EL. 8'-0" EL. 8'-0" STRUCTURAL ENGINEER: R OVE C SHINGLES R IN �Al L OF EVAN AKSELRAD NEW EX'G GARAGE DOORS TO REMAIN REMOV 'G 16 JAY STREET, FL3 WIND NEW YORK, NEW YORK 10013 INS LL OF T 917 689 010301 ISSUED TO FOR DATE DOB 1 1 .30.2020 FINISH FLOOR FINISH FLOOR EL. 0'-0" EL. 0'-0" 1 EXISTING EXTERIOR ELEVATION — NORTH 2 EXISTING EXTERIOR ELEVATION — WEST SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" RIDGE RIDGE EL. 15'-1 1/2" EL. 15'—1 1/2" B.O. BEAM B.O. BEAM EL. 14'-6" EL. 14'-6" EXTERIORNEW LIGHT FIXTURE 12" 12" 8" 81, PTD FASCIA NEW CEDAR SIDING SHINGLES 'vo ,� 9 PTD WD TRIM EW ROOF INGLES B.O. BEAM B.O. BEAM EL„ 8'-0" EL. 8'-0" NEW EDA DRAWING TITLE SIDING S NGLES NEW UTT & GARAGE DO SPOUT NEW GUTTERS W WINDOWS & EXTERIOR & DOWNSPOUTS PTD WD TRIM ELEVATIONS — 3 ,A (30 B NORTH 8c WEST FINISH FLOOR FINISH FLOOR EL. o'—o" EL. o'—o" A- 200 . 00 DRAWING NUMBER: 3 PROPOSED EXTERIOR ELEVATION — NORTH 4 PROPOSED EXTERIOR ELEVATION — WEST. © REXRODE CHIRIGOS ARCHITECTS SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" RENOVATION OF: CREWDSON RESIDENCE 675 SKIPPERS LANE RIDGE RIDGE ORIENT, NY 11957 EL. 15'-1 1/2" EL. 15'-1 1/2" B.O. BEAM B.O. BEAM EL. 14'-6" EL. 14'-6" ARCHITECT: REXRODE CHIRIGOS ARCHITECTS REM. V X'G R06 HINGLES FO I TALL OF W 10 EAST 23RD ST., 6TH FLOOR NEW YORK, NEW YORK 10010 T 212 387 7980 F 212 260 2794 r6, IN I B.O. BEAM B.O. BEAM EL. 8'-0" EL. 8'-0" STRUCTURAL ENGINEER: REMOVE EX'G CEDAR SHINGLES REMOV G EVAN AKSELRAD FOR INSTALL OF CEDAR OGLES NEW T14FOR STALL OF NEW 16 JAY STREET, FL3 NEW YORK, NEW YORK 10013 o T 917 689 100301 i ISSUED TO FOR DATE I I I I IYTT FINISH FLOOR FINISH FLOOR DOB 1 1 .30.2020 EL. o'—O" EL. o'-0" REMOVE EX'G WINDOW REMOVE EX'G WINDOW & DOOR FOR —JFOR INSTALL OF NEW INSTALL OF NEW 1 EXISTING EXTERIOR ELEVATION — SOUTH 2 EXISTING EXTERIOR ELEVATION — EAST SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" RIDGE rift RIDGE EL. 15'-1 1/2" EL. 15'-1 1/2" B.O. BEAM B.O. BEAM EL. 14'-6" EL. 14'-6" g ED A V44 A, 12" 12" O¢ OOF � 8" 8" HINGL PTD FASCIA B.O. BEAM B.O. BEAM DRAWING TITLE EL. 8'-O" EL. 8'-0" NEW WINDOWS N WIND WS GARAGE & D D TRIM & PTD WD TRIM NEW BUTTER & SE AR NG NEW CEDAR �� j1nL DOWNSPOUT INGLES ELEVATIONS SIDING SOUTH SHINGLES 3 1 C o 3D & EAST NEW GUTTER NEW GUTTER & DOWNSPOUT & DOWNSPOUT FINSH i ELI O'-o" EL.ISO-0FLOOR A- 201 . 00 NEW HOSE BIB NEW DOOR & PTD WD TRIM DRAWING NUMBER: &SP ROPOSED EXTERIOR ELEVATION — SOUTH PROPOSED EXTERIOR ELEVATION — EAST REXRODE CHIRIGOS ARCHITECTS CALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" RENOVATION OF: 2 DOOR SCH EDU LE - ` ^ DOOR DOOR SIZE MATERIAL SECURITY SCREEN REMARKS T.O. RIDGE C R E W \/DS O N NO. TYPE. W X H THICKNESS DOOR FRAME FINISH CONTACT DOOR GARAGE RESIDENCE 301-A A 2'-6" X 6-8" 1-3/4" 1 WD, I WD. PTD. NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO INSTALLATION. SCREEN DOORS WHERE NOTED 675 SKIPPERS LANE \/\\/' I N DOW SCH EDU � E AA HALT WDW TYPE EX'G ROUGH OPENING WDW ROUGH OPENING SIZES WDW DESIGNATION GLAZING FRAME SHADE OPTIONS COMMENTS ORIENT, N Y 11957 R00 SHINGLES N0. W. X H. W. X H. MATERIAL GARAGE 301-A A 2'-11" X 4'-0" 2'-7" X 3'-9 1/2" UDHG2 2620 DOUBLE-PANE LOW-E INSUL. CLAD/WD. 301-B A 2'-11" X 4'-0" 2'-6 3/4" X 3'-9 1/2" UDHG2 2620 DOUBLE-PANE LOW-E INSUL. CLAD/WD. ARCHITECT: 301-C A 2'-11" X 4'-0" 2'-8" X 3'-9 1/2" UDHG2 2620 DOUBLE-PANE LOW-E INSUL. CLAD/WD. 301-D A 2'-11" X 4'-0" 2'-7" X 3'-9 1/2" UDHG2 2620 DOUBLE-PANE LOW-E INSUL. CLAD/WD. REXRODE CHIRIGOS ARCHITECTS NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO INSTALLATION. RCNYS- SECTION 310: EMERGENCY ESCAPE AND RESCUE OPENINGS WINDOWS SPECIFICATION: 10 EAST 23RD ST., 6TH FLOOR R310.1 OPENINGS SHALL HAVE A SILL HEIGHT OF NO MORE THAN 44 INCHES ABOVE FINISHED FLOOR. - SHALL BE MARVIN CLAD ULTIMATE DOUBLE HUNG, CRANK OUT AWNING, NEW YORK, NEW YORK 10010 OR FRENCH CASEMENT (NO CENTER POST) T 212 387 7980 F 212 260 2794 R310.1.1 A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET (0.530 M2) REQUIRED. - STANDARD EXTERIOR CLAD COLOR - PRIMED ON INTERIOR FOR CONTRACTOR PAINTING NEW PAINTED R310.1.2 THE: MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES (610 MM). - STANDARD MULLION PROFILES T.O. EAVE EAVE FASCIA - 4 9/16" JAMB DEPTH STRUCTURAL (ENGINEER: R310.1.3 THE: MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES (508 MM). - PROVIDE FULL HEIGHT SCREENS ALL WINDOWS - GLASS SHALL BE DOUBLE PANE INSULATED WITH ARGON GAS, WITH LOW COPPEK/ E COATING ER EVAN AKS ELRAD - SIMULATED DIVIDED LITES, WITH INNER SPACERS, 7/8" WIDTH N P INTED - PROVIDE WITH ALL HARDWARE, OIL RUBBED BRONZE FINISH IE� BOARD BEYONQ N INTED ODD AD DRIP 16 JAY STREET, FL 3 fR 0 0 M F- I N I S H S C H E D U L E NEW YORK, NEW YORK 10013 T 917 689 0301 ROOM NO. FLOORWALLS CEILING NOTES NORTH EAST SOUTH WEST NEW CLEAR GARAGE CEDAR SHINGLES NEW PAINTED ISSUED TO FOR DATE GARAGE 301 EX'G 'ONCRETE ETR ETR ETR ETR ETR WOOD WINDOW DOB 1 1 .30.2020 TRIM NOTE: 1. ALL FIRST FLOOR CEILINGS TO RECEIVE QUIETROCK & ROCKWOOL INSULATION FOR ACOUSTIC SEPARATION. 2. ALL BEDROOM & BATHROOM WALLS TO RECEIVE QUIETROCK & ACOUSTIC BATT INSULATION. EW ALUM1 M C D AVER 2 DO E HUNG ND \ gmL,T.O. EXG. FIN. FLR.IT +01-01, PARGED EXG. GRADE FOUNDATION WALL VARIES � �ED A�'� 1 TYPICAL ELEVATION SCALE: 3/4 r DRAWING TITLE GARAGE EXTERIOR DETAILS & SCHEDULES A- 300 . 00 DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS ° RENOVATION OF: SEE PARTITION TYPES EX'GWD CREWDSON FRAMING 1„ BLOCKING AS I RESIDENCE 4 REF. SPECS. REQUIRED I 1» PTD. HDWD HARDWD CASING CASING AS 4 HARDWD CASING, PTD. W SCHEDULED PTD./WD FIN. EX'G WD FRAMIN I'." r, REF. SPECS. REF SPECS. / D FIN. /(�75 SKIPPERS LAN E BASEBOARD BELOW I LINE OF BASE AS SCHEDULED BELOW SLIDING SLIDING DOOR ORIENT, NY 11957 5/8" GWB, DOOR X' PTD., U.O.N. EDGE PULL r - - ARCHITECT: I HARDWD FRAME, L _ _ _ Li PTD/WD FIN., REXRODE CHIRIGOS ARCHITECTS Aff FLUSH W/ FACE HDWD RETURN FLOOR MOUNTED IL OF GWB \ GUIDE W/IN PARTITION HINGE xx ] REF. SPECS. FINISH FLOOR I 10 EAST 23RD ST., 6TH FLOOR FLR MNTD GUIDE , NEW YORK, NEW YORK 10010 I T 212 387 7980 F 212 260 2794 OW D DOOR, TYPICAL 3 SLIDING WD DOOR AT GWB JAMB 4 SLIDING WD DOOR AT GWB HEAD SCALE: 3" = 1'-0" SCALE: 3" = 1'—O" SCALE: 3" = 1'—O" I STRUCTURAL ENGINEER: I EVAN AKSEILRAD PTD./WD FIN. 1" HARDWD CASING, 4 REF. SPECS. REF SPECS. �-- LINE OF BASE ( 16 JAY STREET, FL 3 BELOW I NEW YORK, NEW YORK 10013 5/8" GWB, PTD., �— 5/8" GWB, I T 917 689 03101 U.O.N. — CLEAR TEMPERED TIS -- WOOD BLOCKING � vv cLAss \\ — ® — _vk� ISSUED TO FOR DATE / I HARDWD FRAME, _�L HARDWD FRAME, DOB 1 1 .30.20 FLUSH W/ FACE PTD/WD FIN., muj PTD/WD FIN., — — — OF GWB FLUSH W/ FACE SOLID CORE OF GWB RAIL/STILE W/ "INCE HARDWD STICKING 5" 1- REF. SPECS. REF. SPECS. REFER TO EXTERIOR DETAILS 44' TYP. 44 TYP. 44„ TYP. 44" TYP. 4" 2 GLAZED—PANELED WD DOOR JAMB 5 CLOSET WD DOOR, TYPICAL SCALE. 3 — 10 SCALE. 3 — 1 —O 7 DOUBLE HUNG WINDOW SILL 8c HEAD SCALE: 3" = 1'-0" CASING AS SCHEDULED LINE OF SILL BELOW GWB WALL NEW CASEMENT INSULATED WINDOW ASSEMBLY >-Iccc F— CASING AS CASING AS CASING AS \ CASING AS CASING AS CASING AS CASING AS SFECIFIED SPECIFIED SPECIFIED ---T SPECIFIED SPECIFIED SPECIFIED SPECIFIED /\F - 0 0 0 0 0 _5 0 5 0 5 _ _ _ _ = A601 = A601 = A601 11 U U U U U U U cn 1 � 1 3 U' 3 � Of [if A601 0 yy 0 A601 0 A601 0 °° 0 ° o °° 0 8 A601 00 0 0 �� 0 0 IL 0 cn L— 0 M cn m 0 C) I ILy I CASING AS SCHEDULED SHINGLES AS SCHEDULED SEE DOOR SCHED. SEE DOOR SCHED. SEE DOOR SCHED, SEE DOOR SCHED. SEE DOOR SCHED, SEE DOOR SCHED. SEE DOOR SCHED. HINGED DOORS HINGED DOOR HINGED DOORS A'���� A HINGED DOOR B HINGED DOOR C SLIDING DOOR D SLIDING DOORS E E� F 6 DOUBLE HUNG WINDOW JAMB REFER TO SCALE: 3 = 1 —O EXTERIOR DETAILS a ^ ¢ •2 A Cr- CASING AS CASING AS T CASING AS CASING AS - SPECIFIED SPECIFIED FI)ED SPECIFIED SPECIFIED Of Of /i /� /� /� i / o DRAWING TI TLE cn cn o 0 0 ooo z 6 z DOOR 8c WINDOW W / // // // w // // / // / // m A601 A601 0 0 0 0 w / / / / w / / / / / / w w � � z TYPES DETAILS cn N w w z z z wrU-1 (n L cn 3: cn ul) w w w (n SEE DOOR SCHED. SEE DOOR SCHED. SEE WINDOW SCHED. SEE WINDOW SCHED. SEE WINDOW SCHED. SEE WINDOW SCHED. SEE WINDOW SCHED. SEE WINDOW SCHED. FRENCH DOORS W/ GLAZING & CLAD/WD DOUBLE CLAD/WD DOUBLE CLAD/WD AWNING CLAD/WD AWNING CLAD/WD PICTURE CLAD/WD FRENCH G HINGED DOOR W/ GLAZING H HINGED DOOR W/ GLAZING HINGED DOORS W/ GLAZING J FIXED GLAZED PANEL A HUNG WINDOW Al HUNG WINDOW — PAIR B WINDOW B1 WINDOW — PAIR C WINDOW D CASEMENT INTERIOR ELEVATION < < < < A DOOR TYPES &SCALE.WINDOWSCALE: 1/4" = 1'-0" 1/4 = 1 —OA— 130 ,po 00 DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS