Loading...
HomeMy WebLinkAbout28517-Z 9 . . FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT- . Office of the Building Inspector Town Hall Southold, N.Y. L CERTIFICATE OF OCCUPANCY f . No: Z-29993 Date: 02/04/04 TEAS CERTIFIES that the building NEW DWELLING Location of. Property:. 2350 BREAKWATER RD MATTITUCK (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 106 Block 9 Lot 2..4 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 31, 2002 pursuant to which Building Permit No. 28517-Z dated JUNE 28, 2002 was issued, and conforms to all of the requirements of the applicable i lprovisions of the law. The occupancy for which this certificate is issued I is ONE FAMILY DWELLING WITH COVERED FRONT ENTRIES AND ATTACHED TWO CAR '! GARAGE AS APPLIED FOR. The certificate is issued to JEFF & AUDREY GRATHWOHL l{ (OWNER) Jl.. L of the aforesaid building. f . I'I.. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-02-0099 02/03/04 ELECTRICAL CERTIFICATE NO. 683.000 12/10/03 't PLUMBERS CERTIFICATION DATED 12/10/03 KEVIN REMPE PLUMBING it I ized ignature e. Rev. 1/81 p _I a FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. i BUILDING PERMIT i l (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED).. ARMiT )4b. 28517 Z Date JUNE 28, 2002 Permission is hereby granted to: JEFF & AUDREY GRATHWOHL 193 ARROWHEAD AVENUE RIVERHEAD,NY 11901 for CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING WITH ATTACHED TWO t t; CAR GARAGE AND COVERED FRONT ENTRIES AS APPLIED FOR d' E i L at premises located at 2350 BREAKWATER RD MATTITUCK ii County Tax Map No. 473889 Section 106 Block 0009 Lot No. 002 . 004 4� pursuant to application dated MAY 31, 2002 and approved by the ,f Building Inspector to expire on DECEMBER 28, 2003 . i Fee $ 1, 732 . 20 �7 Authorized Signature ORIGINAL �f Rev. 5/8/02 I Form No 6 TOWN OF SOUTHOLD BUILDINGDEPARNENT TOWN:HALL 765-1802 ' APPLICATION FOR CERTIFICATE OF OCCUPANC'— his apps cation must be filled in by typewriter or ink and submitted to the Building Depar1fi i't wi lfoljo^ I j A. For new building or new use: 1 8 1. Final survey of property with accurate.loeation of all buildings,property lines, streets,and um,,` , a r' g P P Y r topographic features. L "ls a c T(yVVei.Ur J 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical,installation,from Board of Fire Underwriters. j 4. S6rorn siat4ement fromplumber certifying that the solder used in system contains less than 2/10.of 1%lead. 'i! •. ,i:dustrial buil(4ug,multiple residences and similarbuildings and installations,a certificate !'( •,al:('i+; ::I': :ur !':, ;; architectorengineer responsible for the building. ; 6. S I ;;'; I' r• ;u 13,!;::,! .`aproval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses, or buildings and"pre-existing"land uses: l• Accurate slriwey of property showing all property lines, streets,building and unusual natural or topographic features, ! 2. Agproperly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is doniaed;ihe.Building?hispector shall state the reasons therefor in writing to the applicant. I ! C. Fees 1 1. Certificate of Occupancy-New I yelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00, Accessory building$25.00,Additions to accessory building$25.00, Businesses $50,00. ! 2. Certificate of Occuoaney on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 r I 4. Updated Certificate of Occupancy- $50.00 / 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 i Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: I j rCj;. House No. Street Hamlet Owner or Owners of Property: Suffolk County Tax Map No 1000, Section fb(,- 9 - �.(� Block Lot Subdivision Filed Map. Y) a- Lot: Permit No. ��`OS - Date of Permit. (} Applicant: S!� (-� Health Dept. Approval: a Underwriters Approval: Planning Board Approval: S f-off-C a� (A�-311l) 7-00 Z- A y&vfkwMIjJ�f6YQf-hwhI Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ r, � _�_`�99 654q plicant Signature ri 1 ., rte r4 ®r, P b: 30'tllie 7ge@ ,�:ej 3d$S-9rfla sa w wo, Niw yalk t is? i OFFICE OF THE WILDING INSPECTOR OR TOWN Ott SOUTHOLD M-- DATZ:', 0 htsll�lin Peruit tai. {i watt print Plumber: Vqiw rp-lasoprn-v B vmrtify that the $older used in this water Supply alraxeI rontabng lass than 2/10 of It load. jPlumbors Si4in—Cur i DIANE LOPEZ EDWARD wxK315i '�� before � taiffi noxary Public.State of New York :Wmli0Eu95424,mySuffolk 7, ©-� Cgnmission Expir July 7, day ®f OtPr� 11Qr (� Notary Public r county f 54. 1• ••%. ti l p • r l ..5�'• ♦:f.:�., •r •1, �.. .�:.:�•�!. l.' I-Y•�:J N:: A • I 'i•.5:� • I:.. ' •"V•' �{ .{p �iC tiiY;? i.Y:�:;yryi;;'N a i�1'TS', 'd .� . jf s.t .•tij. rr. % ° ,nWl I.v A. is ':l. 0 :ki::��l �••'1 b � . � !' '.. .1 �..�.��'' . . �� � W. V, .illl�a:,;i#:i'ix:1':•.. .+ . '::�tal•?°a:d;',��.i:;,..F.�,; .�,i, �a:r;+j:i'. Electrical Inspection Certificate Issue Date Electrical Inspection Service, Inc. Application 12/10/03 375 Dunton Avenue 68300C East Patchogue,New York 11772 ' (631),286.6642 Issued To: Jeff Grathwohl Street: 2350 Breakwater Road Village: Mattituck Zip: 11752 Town: Southold F. _ Section: Block: Lot: moi' I Contractor: Peconic Electric Corp. (L).(cc) Lic. # 5230-E ' k Was examined and found to be in compliance with the National Electrical Code. I ❑ Commercial ❑ NV Defects ❑ Pool ❑X 1st Floor ,0 indoor ❑x Basement ❑Hot Tub X1 Residential ❑ Det.Garage 0 Attic X❑ 2nd Floor X❑ Outdoor ❑ Addition ❑ Survey Switches Receptacles Fixtures GFl Heaters AIC Fans 39 52 60 6 . q Dishwasher WasherlAmps Dryer/Amps Oven, Range/Amps Microwaves 6 1-20A 1 20 1 30 1 30 1-20A Furnace Oil Gas Circulators Smoke Detector Bell Transformer r r x 8 1 ' Meter Amps Phase UGIOH Jacuzzi Television CO Detector 7 1 200 1 ❑X / 2 - Bldg. Permit: s; Other Equipmentto- %, 1-Central Vac =- h -20A Air Handlers -40A A/C Comp. Hugo S. Surdi President Rough Inspection: 10/15/2002 Inspector EdScavelli l I 'Final Inspection; 1210912003 i Inspector: Sean P. Hightower •• } t ' This certificate must not be altered in any manner. Inspectors may be identified by their credentials. f F �� Wiz._ _ %�- _ - _ _'+S`g% _ - - - �-•�3'rzG'_..- `�'?'��°�?. ��_r- •s,;:' � s TOWN OF SOUTHOLD PROPERTY RECORD CARD `— � OWNER STREET VILLAGE DI$T.l SUB. LOT Y Cd ACR. REMARKS ( 00 TYPE OF BLD. z9a- 9 asp y PROP. CLASS LAN IMP. TOTAL DATE G'7 � '-��_ ., � � r- • (... 10�d7 1 — a j)� -�- �trCc�acx t� �'"`� �,�c. Yev 2 Z — fit r �c Sc kn kQ V ffIC,C( I`r✓_ e �(" tl R °2-ran .Frau i ofit- to x a re .,�.ro-- nye ?uwcR G -�sj o. E I I _ 1 s FRONTAGE ON WATER TILLABLE FRONTAGE ON ROAD WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT TOTAL Applicant/ Owners Name. Reviewed: l 0y Architect/ Date Engineer. Submitted: L-13 s SCT1v1 !t: District: 10_00 Section_ Block: Lot: ` Project q Subdivision Location: o 3 5-D /�1 e t tirt� �_ �- Name: I Single 8_ separate Required cer4tficauon: Yes/No) f Req Req. gnuig lltslnct (t.ot size:- AC8t2(�I P-ot eaveragc�,Propascd Req �.r Req. �� Req. /� t �. tfront Yard �Proposed. (Side Y rd I'rotwscA �J (Rear Yard ._GO Proposed f C -� JCC}rSp � 1 Project lDescription: (A, AGENOtRERMITS Permit f REQUIRED FOR REVIEW N.A. NO YES �Number i Suffolk County Health Dept. xlF New York State D. E. C. Town Trustees Town Zoning Board approval: Town Planning Board approval: Flood Plane Elevation??? I Flood Zone: X s 6 to � E . -L�-4�- -74 se "-rej 4 - t is Town Of Southold P.O Box 1179 Southold, NY 11971 (631)765-1800 RECEIPT #2931 05/31/2002 Thomas,'Charles ! ' Po Box 877 i `Jamesport, NY 11947 Received $ 10.00 for Septic Permit- Construct- Resid., on 05/31/2002. Thank you for stopping by the Town Clerk's office. As always, it is our pleasure to serve you. Elizabeth A. Neville Southold Town Clerk' i M-1802 BUILDING DEPT. INSPECTION PECTION _ [ Vr FOUIVOATION IST j ] ROUGH PLOD. I ] FOUNDATION,2ND, [ ]= INSULATION j ] FRAMING j ] FINAL j ] FIREPLACE & CHIMNEY REMARKS: DATE INSPECTOR , AoP577�- 765-1802 BUILDING DEPT. INSPECTION [ I FO ION 1ST [ ] ROUGH PLBG. [ FOUNDATION 2ND [ ) INSULATION I, [ } FRAMING [ ] FINAL [ I FIREPLACE & CHIMNEY REMARKS: _ Y j,Jl DATE INSPECTOR � j l M-1802 ( BUILDING DEPT. I ! INSPECTION i [ ] FOJND TION iST [ ] RO H PLBG. ] F NDATIO INSULATION ] FRAMIN [ ] FINAL j ] FIREPLACE $`CHIMNEY REMARKS: L . � DATE " M A ' INSPECTORS 765.1802 BUILDING DEPT. 1 NSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. ] .FOUNDATION' 2ND.: [ ] INSOLATION ON [ ] FRAMING [ �FINA� L. [ ] FIREPLACE & CHIMNEY REMARKS: Acr---STS' I DATE 140 2, INSPECTOR 1 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. ] FOUNDATION 2ND [ ] 1 ULATION [ ] FRAMING [ ] FINAL I < [ ] FIREPLACE & CHIMNEY REMARKS: �./ .. 6 dollr II 4 S� DATE A924F INSPECTOR II 765-1802 BUILDING DEPT. INSPECTION FOUNDATION IST [ ] ROUGH PLBG. } FOUNDATION 2ND [ ] INSLATION } FRAMING j FIN FIREPLACE 8: CHIMNEY R MARKS: Fi III 7 il I ' I jJ j1 i DATE INSPECTOR � ill r 'I I L 7 M-1802 BUILDING DEPT. k INSPECTION` [ ] FOUNDATION IST [ ] ROUGH PLBG. t } [ ] FOUNDATION 2ND [ I INSULATION [ FRAMING ( FINAL FIREPLACE & CHIMNEY I� REMARKS: e 2�c DATE INSPECTOR t i BUILDING' PT. INSPECTION } FOUNDATION 1ST [ OUGH PLBG. FO ATION 2ND [ } INSULATION [ FRAMING [ } FINAL j FIREPJ� CE S CHIMNEY REMARKS: DATE INSPECTOR ' I ' JJJ Iii • i Man • is , INSULATION STATE ENERGY CODE aff PW OtA EWA 1 OWN OF SO, %r' i BT 17 3 G EI vI1T AP.PLICAT1E�IV'CHECXLZ[S�BUILBT P iAN'' 3 T t l� Do you have or need t6^„ a� re t 2 �( TONVN, Board of Health SOUTHOLD,NY 1 1 .. 3 sets ofBuildiug Plans TEL: 765-180! spy PERMIT NO. Q-g'S-1 7 f-� Check r Septic Eozm Tnnstees Examined 0> Contact• Approved 20 0,:3- Matl3o: Gfyu�c 7F/c q"S Disapproved a/c ?06pk 77 Ji4WLq;ffb04- ky/*( l Phone: 727 73 —0LZGe - Building fi r APPLICATION FOR BUILDING PERMIT Date 2002-- INSTRUCTIONS 0oZINSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans,accurate plot plan t6scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work c.No building shall be occupied or used in whole or in part for any purpose what-so-ever until a Certificate of Occupancy is issued by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition herein described The applicant agrees to comply with all applicable laws, ordinances,building=(Signatare ations, and to admit authorized inspectors on premises and in building for necessaiy inspectio or name,if a corporation) �.Q 6x 5T JAXE-50�t K)V 1104-7 (Mailing address of applicant) �- State whether applicant is owner,lessee, agent, 96 ,engineer, general contractor, electrician,plumber or builder l AeL,�s wt ame of owner of premises V44 M, '�4gAl:4t log- (as on the tax roll or latest deed) applicant is a corp on, signature of duly authorized officer (Name and title f corporate officer) Builders License No. L lumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: r ��EkW4-'n-'2 �nr� V��l-T`fiTUUG- House Number Street Hamlet Vl .AZ 4 ,c > �y 3, County Tax Map No. 1000 Section /tJ(o Block 9 d Lot � Subdivision Filed Map No. (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy Srnx,I G, o� - 3. Nature of work(check which applicable): New Building__! Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost' 0'0,0 Fee (to be paid on filing this application) 5. If dwelling,number of dwelling units_ 4Number of dwelling units on each floor If garage, number of cars 7- 6, 6. 'If-b,�iness, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dim ions of existing structures,if any: Front Rear Depth Height_ Number of Stories Dimensions a same structure with alterations or additions: Front Rear l Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front !190 Rear l fi 5 `f 2 Depth �5? ± 10. Date ofPurchase,)Aj Of Name of Former Owner 6-n4 Awri �z1(tp �pNE 11. Zone or use district in which premises are situated -O© 12. Does proposed construction violate any zoning law, ordinance or regulation: 1J0 13. Will lot be re-graded 00 Will excess fill be removed from premises: 14.Names of Owner of premises 6�0m�l&a . Address Phone No. 7Z-2-5722 s Name of Architect C./{srlife5 /f+v�sef33 Address ie No 727- 2M Name of Contractor Address Phone No. i 15. Is this property within 100 feet of a tidal wetland? *YES NO IF YES, SOUTHOLD TOWN TRUSTEES PERMITS MAY BE REQUIRED 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. it 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) COUNTY OF,�p 6C" W1. being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, i (S)He is the l e� A4 I (Contractor, g, Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the k will be performed in the manner set forth in the application filed therewith. Sworn to before me this ay of 200, 1 Notary Public Signature of Applicant I LYNDA M.BOHN NOTARY PUBLIC,State of New York No.01806020932 Qualified irrSuffolk Coun Term Expires March 8 20 a ..yk OAD DATE; APR. 20, '02 -NALJGLES R 80-,34 , 150 '7 245. 5 9947 55. 46 ) • LE-6;75- i A 15 opo r- 0, 30 TEST HOLE N 45 DATE: 9/24/01 969 F o?45 12 ppLIn z V 92 Ir (71 0.0' Z AREA= 1 . 00 ACR .1 Q C) BROWN z s N T.-A LOAMY SAND 'n f1j < Q (SM) 3,01 C)l SILBROWNTY SAND z ryz u X (SM) 6.0' ta Ili. 5; 10 w U.0 w pl. PALE . 1BROWN Lij (Y U0 0 AND BROWN -zo: > tILI FINE SAND 12 >- (SP) < -,e 0 501-OP Lo u U) LL 1p , ^ rF gr 1 15.0, 0 m 0 LOO ON OF 0) 1& it BROWN TEST OLE 14. Lt., SILTY SAND W < 6,4 x (SM) Q ILI 7- 19.0' uJ 2. 3 0 r) 0 BROWN m 0 )7 7101`1 w FINE SAND SP) S 82*2YATiGN 0 1NSP9010w. ION REWIRED FOR SANITARY SYSTEM SITE PLAN _MLII&TH QEPA ."T NOTES: 5GALE: lit 401-011 I. ELEVATIONS ARE REFERENCED TO N.6,V.D. 192cT DATUM ts) t- EX15TIN& ELEVATION5 ARE SHOWN THUS: 2, REFER TO FILED MAP FOR TEST HOLE DATA. 3. MINIMUM SEPTIC TANK CAPACITIES FOR A I TO 4 BEDROOM HOUSE 15 1,000 GALLONS. I TANK; 8' LONG, 4'-E3" HIDE, DEEP c 4. MINIMUM LEACHING SYSTEM FOR A I TO 4 BEDROOM HOUSE 15 300 sq ft 510EHALL ARE ;� 1 POOL; 12' DEEP, Vdla, MAP OF DESGF,1E3ED PROPERTY PROP05PP EXPAN51ON POOL SITUATED AT MATTITUG< TOWN OF SOUTHOLD, SUFFOLK GOUNTY, NEW YORK PROPOSED LEAGHINO POOL x D15T, 1000 5EC,. 106 BLK.cl LOT 2.4 moposEo SEPTIC TANK 71, 411 NAUGLES RoAd '5 2q 9 55. 6 4 xt q;( • ` �: .' � IN ,..� U 6-c 7 3a.c ss ' 3� '''Y ry TEST HOLE 9 6 . . A' DATE:B/24/67- K , , y Z" l N AREA-- 1. 00 ACRES o tz.o' r 4 �r �RowN -, m LL LOAMY SANl9 BROWN W I-- {: y o $ SILTY SAND V O SM 8.p' Nlu PALE LJ Q w o k AN�ROWN BRfNN ' W a < 4 FINE SAND OpDa _ ui7k Qe n , Q �, ,. 2 ORs er$ Iq --yy �R p e° -n "rt hw '4 .F/0(/s�. 15.0' - c ' Juj % oN r J 6.4 44 � � a S SI TY AND �^^ ,1� TfS7 Hot¢LLJ 5 , 3 h.v '1• lii 7.1 10 w FIN�spj rra �s �J �rj S 8 t2 8 2602 �J vAn��Nsr�etwH R�cau� Lwum.a �a k >M MNRAW SYS S I T E P L A N - 0 r 5GALE: I" 40'-0" i 1. ELEVATIONS ARE REFERENCED TO N.O.V.TD. Id21 DATUM AIN br' EXI5TINO ELEVATIONS ARE 5HONN THUS: �. 2. REFER TO FILED MAP FOR TEST HOLE DATA. 3. MINIMUM 5EPTI6 TANK CAPACITIE5 FOR A I TO 4 BEDROOM HOUSE 15 1,000 6ALLON5. d I TANK; & LON6, 4'-3" HIDE; 6'-7" DEEP 4. MINIMUM LEACHING 505TEM FOR A ) TO 4 BEDROOM HOUSE 15 300 5q FC 51DEHALL AREA. I POOL; 12' DEEP, V dta. }-a MAP OF DE5G 'IE� fD >'R01 '� TY 51TUATED AT MATTITUGK RaPoSED EXPAiISION Pool TOWN OF 50UT'HOLD, SUFFOLK COUNTY, NEVI YORK _r, r� � FE PROPOSED LEACHING POOL D15T. 1000 SEG. 10(b BDKA, LOT 2.4 PROPOSED SEPTIC WANK L 5. THE LOCATION OF HELLS. AND OE55POOL5 5HOHN HEREON ARE FROM FIELD r o55ERVAtio'!15 ANV/OR [;?ATA OBTAINED FROM OTH4f 5; w R O A � DATE: APR. 20, '02 N AU GLES S 80.34 ,,Do " � ju � 0 ( 2q.5- 57' 55 46 E S �;PO�E 6'5 10 j 5 - _ 9 - 700 - - --- -- --- - TEST HALE - - y N 780 DATE! 9/24/01 — 969 6 ppL 4 5 J_ 0.0' 0 g2.8_ r AREA= 1 , 00 ACRES LOAMY SAND (SM) 3.0' OBROWN o z SILTY SAND w (SM) 6.0' C (J1 � - PALE y BROWN D BROWN j FINE Q II opo O SP r„ / Q bg, 2 wSfrD ED \j\} ''�wj�. e- EDATER 'RN _W FRA�rR ✓ PRP 1- O M _ _ _ 0) 15.0, BROWN Lo < SILTY SAND w�1An 4 QNLO �` r ,some TEST HOLE F �j60' (SM) 19.0' { ((W.L.- o 2 5.2. .., W WBROWN O FIN s 182620' 10 ' VV �SP) ND 25.0' SITE PLAN OTE5. SGALE: 1'' = 40'_0" I. ELEVATIONS ARE REFERENCED TO N.G.V.D. Ig2q DATUM EXISTING ELEVATIONS ARESHOWN THUS: o 2. REFER TO FILED MAP FOR TE5T HOLE DATA. 3, MINIMUM 5EPTIG TANK GAPA6ITIE5 FOR A I TO 4 BEDROOM HOU5E 15 1,000 6ALLON5. 13 V I TANK; b' LONG, 4'-3" HIDE, &'-7" DEEP c- 4. MINIMUM LEACHING 5Y5TEM FOR A I TO 4 BEDROOM HOUSE 15 300 5q ft SIDENALL AREA. F" I POOL; t2' DEEP, b' dia. j MAP OF DESGRIBED PROPERTY 4-1 51TUATED AT MATTITUGK PROPOSED EXPANSION POOL TOWN OF 5OUTHOLD, SUFFOLK COUNTY, NEWYORK 0 r PROP05EP LEACHING POOL L ll0 PROPO5ED 5EPTIG TANK i DIST. 1000 5EG. 106 BLK.ci LOT 2.4 6 p m 5. THE LOCATION OF HELLS AND GE55POOL5 SHOWN HEREON ARE FROM FIELD OBSERVATIONS AND/OR DATA OBTAINED FROM OTHERS. SURVEY OF PROPERTY SITUATED AT MATTITUCK TOWN OF SOUTHOLD NEK NAUGLES ROAD S.C. TAXK N 00000- 106-09 -02.4 SCALE 1 "=20' SEPTEMBER 3, 2002 JCNATlUS C NNONE -- 245.57' S 80•34,5 0 „ E AREA = 43,563.10 sq. Ifi ,a �° .f� . r��_ F' f. 1 .000 CO. S MAR ICSICAN° m °4 tip aHuo "T 55.46 _ CERTIFIED T0: E. NI° N° Pe T14 AHETIi AR - --j o & ELIZ `_pvFFHFAa wIREs ^ _. T-- •— JEFF GRATHW64♦-� AUDREY GRATHWOHL pplE _ e a e JI 1IIIL11Y� n " ' de zmRT Row c �g' 45'30, E z� "IGNT OF WAY }° in N FRAME HOUS vERHv'o vacs - 20' WIDE R - a�A / / O 0 2 'C' a as bo a — ¢e z• s,o. CONCRETE FOUNDATION my • � � � � Tp• � �Oa S• O LyJI Z-1 CHIMNI (v o J5'ry ryT$'o O1 O y V11 0 li] m d. % O ` TION TO THIS SURVEY' IS A VIOLATION OF b - •�- II I 252 .3C)' �/ SEC TON7209LA OFRIZED �THE RNEW ON YO�DSTATE jEDUCATION LAW, `. . ED COPIES OF THIS SURVEY MAP NOT BEARING O I THE L1ND SURVEYOR'S INKED SEAL OR 41 EMBOSSED LID SHALL NOT BE CONSIDERED •O 9 TO DE A VALID TRUE COPY ^ O 7//Q/ 5)v CEREFICATIONS ERSONTm HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY d •~ " ° DAVID W°/C OPER T PREPARED. AND ON HIS BEHALF To THE TELE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSIG EES FISHED HEREON. AND A C o 2.20 1 O„ � e TO THE ASSIGNEES OF THE LENDING INSE- O U YY TIffION CEN11F1CATIONS ARE NOT TRANSFERABLE. Q o- - as a THE OF RIGHTS OF WAY AND/OR EASEMENTS OF RECORD, IF ANY,, NOT SHOWN ARE NOT GUARANTEED. a d PREPARED IN ACCORDANCE WITH THE MINIMUM BY THE FOR TELL APPROVED AS ESTABLISHED Joseph A. Ingegno BY 1SU LJ ALS. AN APPROVED ANO ADOPTEDTEN FOR SUCH USE 6T E NEW YORK STATE UNa E;A V-NLand Surveyor File Surveys - Subdivisions - Bde Plans - Construction Layout PHONE (631)727-2090 Fax (631)727-1727 Cf Vii; 4 G l: OFFICES LOCATED AT MAILING ADDRESS 1380 ROANOKE AVENUE P.O. Bax 1931 NY.S. Lm No 49668 RIVERHEAD, New York 11901 Riverhead, New York 11901-0965 22-306A I F`R - 3 2MI4 SURVEY OF PROPERTY SITUATED AT - MATTITUCK TOWN OF SOUTHOLD NAUGL,ES ROAD SUFFOLK COUNTY, NEW YORK _ S.C. TAX No. 1000- 106-09 -2.4 SCALE 1 "=20' SEPTEMBER 3, 2002 245.57 S 80 f�N9T/US gNNaAE DECEMBER 22, 2003 FINAL SURVEY 34'50„ E AREA = 43,563.10 sq. ft. 55 1 .000 ac. TgOMAS/MA�ARSI ANO miuTru of3 -`GVERHGO WrR •46' as ELIZABETH _ — & wl6cs -' obi - E OIftT ROM 7$•45 usoeA — _ _ _ WA N RIGHT OF FRAME H ,wrDH�G wlaEs — 2O' WIDE _ 1 _ Gal w 1 • 45,• - • Y 2>.3' n- - ••e—la.� . := U. 264' 0.i STORY FRAME HOUSE & GARAGE re a•� CL'RTll''ll''D T0: W ULSTER b n ROOF OVER r0p s' p FIDELITY SAVINGS NAT ONALB TITLE INSURANCE COMPANY OF NEW YORK aw000 S.? a � JEFF GRATHWOHL AUDREY ORATHWOHL • z . re.s• nnMNEY LO �' •d ✓!i, TEIy SEiNICE j' a5'e H2.I'o O) COcq H°p STOVER o -9E' .. 9.' I.' - O 1 I • R 1 SEP (N ' ♦ RC iANk b • 252.30' Ta 7HIS S= IS RA''vlounoN OF \i SECTION 7209 OF THE NEW YORK STATE N a EDUCATION LAW " O 41 COPIES OF THIS ORJ I MAP NOT BEARING THE LAND SUR� SEAT OR EMBOSSED SEAL SHALL NOTDBE CONSIDERED • .� .. - n TG BE A VALID TRUE COPY CEWffICAPONS INDICATED HEREON SHALL RUN 4 A. - N�D�F ONLY TO THE PERSON FOR WHOM THE SURVEY W. COOPER IS PREPARED, AND aN HIS BEHALF TO THE <• DAVID TRUE COMPANY, GOVERNMENTAL AGENCY AND q `r.1 LENDING INSTIUD°N LISTED HEREON, AND • • S $2.20' 1 On v' a TO THE ASSIGNEES OF THE LENDING INSP- 0 iUPON. CERTIFICATIONS ARE NOT TRANSFERABLE OQ ' aQ THE EXISTENCE OF RIGHTS OF WAY - ' AND/OR EASEMENTS OF RECORD, IF n ANY, NOT SHOWN ARE NOT GUARANTEED. PREPARED IN ACCORDANCE WITH THE MINIMUM BYA THE LI `°R_ LE SURVEYSVE "S ESTABLISHED Joseph A. Inge gno BY THE LI VEp S E A°BISHE FOR SUC RK STATE LANA PFLE A e<j ' $� Land Surveyor "11a7 a An " � Th Title Surveys — SubdiwaTons — Site Plans — COGSYN HOD Layout xafi�sfCI P96`�� PHONE (631)727-2090 Fax (631)727-1727 OFFICES LOCATED AT MAILING ADDRESS NNE LIc, No. 49668 1380 ROANOKE AVENUE P.O. Bax 1931 RIVERHEAD. New York 11901 Riverhead, New York 11901-0965 22-3068 RIDGE VENT )r ''M' T"y�'•i - - ASPHALT SHINGLE ROOMN6- - - E ��" y -Aut'd 14 _ RIDGE VENT _- ASPHALT SFIIN6LE ROOFING- - � W cn Li RIDGE VENT m ___ ASPHALT SHINGLE ROOFING - _ 12 - - - _ _ _ _ 5EGOND FLOOR PL. HT. - RAKE BOARD (TVP) - - - - MASONRY CHIMNEY K 1 Eli, 1171 E: CEDAR PERFECTION SHINGLES 5EGOND FLOOR HEIGHT _ - �" - -- -- _ - I" X 10" BELT BOARD ELEV. 10'-0" I" x 10" BELT BOARD 1 _F _ DECORATE _- _ - -- - _ _ _ -- - U LLJ CORHLP2 MOLDING - - CEDAR PERFECTION SHINGLE, IV - _- - _ - _ _- -- -- - - _ - - -- - WINDOW TISHUTTTRS _ - - WITH 5/4" X 4" CORNER BOARDSIL101 1 :11 AND WINDOW SURROUNDS - - -- - - - 171 - -- -- - - _ - ❑ - - _ TH W - CEDAR PERFECTION SHINGLES 4" CORNER BOARDS AND WINDOW SURROUNDS _ CEDAR PERFECTION SHINGLES - - -- _ - - - - FIRST FLOOR HEI6HT - _ I" X 10" BELT BOARD I" X 10" BELT BOARD Y I" X 10" BELT BOARD ELEV. O'-0" � GRADE O 6RAVE W II II D O> z I I II II I I I I I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J FRONT ELEV TINI 0 _ \ I J SCALE: 1 /4" = l '-0" - - - - _ - - J - _ - _ - - - - - - - 1 - - - - - - - - - -� -� T.O. GELLAR FLR. - _ _ - - - - - _ - _ _ _ _ _ _ _ _ _ _ _ _ _ . - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I - - - I - I` - - - - - - - - - - - - - - - - L - - - - - - - - - - - - - - - - _ -- - _ - - - ELEV. B'-II" Ur RIM X 2" TRIM ON I"' X 8" I" X 2' RAKENBOARD 12 11 12D 12 PROVIDE ANTI-SCALD AND/OR RIDGE VENT ASPHALT SHINGLE ROOFING THERMAL SHOCK PREVENTING DEVICES AS TO PART. 902.6IK) - RIDGE VENT ASPHALT SHINGLE ROOFINN.Y. STATE BUILDING CODE. -- _ - - \ __100F- RIDGE VENT - -- G- _- - _- - -- _- - -- -ASPHALT 5HIN6LE ROOFING - - _ -- -- - PLUMBER CERTlfiC."7;':"jAj - ON LEAD CONTENT" e J l m- If copper tubing is used _ for water distributing - — ERTIFiCATE OF OCCtJP'A,^U' 1 System; piping shall be - __- - - - - - -- --- - - -- - - - - - SOLDER WIE1/1f1,,l,ll �FFR of types K or L only o SUPPLY SK�sIL v'I (',i J., Y UNDE CERTIFICATE ~ o WRITERS CERTI w - XCEED 2/1 - - - - - -- -- _ - _ - - - -- - - L' 0 of I% e".r�.a1J'. REQUIRED 12 - -_ - _- - 12 - � -_- -- - - - - - - - - _ _ - - 7 14 .- _ - - - - -- _ 141 / PROVIDE ' HR. FIRE ��ND FLOOR PL. Hr. L,, a z /, - 13 - PAR T717 3R)IONOTO G a - o IE _ -- - - PLUMBING o ( ( ) 6L PLUMBING wMBIN SWASTE i2� ® � - - � - - N.Y. STATE BUILDING CODE. TER LINE NEED W PROVIDE OPENINGS FOR TESTING BEFORE COVERING - ` - - - - - - - - - - - - CEDAR PERFECTION SHINGLES \'� -- - --- EMERGENCY ESCAPE ASJITH 5/4" X a" CORNER BOARDS - REQUIRED BY PART. 714 Of AND WINDOW SURROUNDS � - - N.Y. STATE BUILDING CODE. + n (n E U n PROVIDE SMOKE-DETECTING O n AE ® ® - ALARM DEVICES ® AS TO PART. COD �— + CEDAR N.Y.S BUILDING CODE. r WITH 5/4" - - _ At D0 NOT PROCEED WITH o - - -- 1080 OH DOORS 1080 OH DOORS - FRAMING UNTIL SURVEY _ w OF FOUNDATION LOCATION APPROyEDASNOTED (� a _ - HAS BEEN APPROVED. OATL" .L, ILuo_�.B,P#a� x L p DING CiEPARTMENT GRADE d _ E — - - — - - - - - - FIRST FLOOR 7765. AA,I ]'B a +I,1 FOR T -� m ._" 6RADE GRADE FOLLOWING INSPF'G IiZQUIR U a FOR POUR,:O +.1ItB,E,aS 3. NSULATIONS�If�ilNC u PLUMBI C I� / /� � I _ _ — _ _ _ _ _ _ _ _ _ _ c �-IF I �III C \ / n T SHY. No, 2 SIDE VL_IEIIVATION I � 3 SIDS IICILLVA IIO � BECOMPLETF1"'111J'TIONMU SCALE: 1 a" 1 —o' - - - - - - - - - - - - - - - - - - - - — - - - - - - - - - - -scALE �1 — 1 —o WiHDUT CERUNLAWI UL STATE CODE9CONO UCT N 1 9 N SHALL IR 3 OF THE N. L L - - - - - - � - - aN13BLE FO 17- - - - - - - - - - - - - - - - - - - - - I - - - - - � - - - - - - - - - _ -CI � OF OCC NS-,AUCTION ERROR — — — — OF 5 _ �E C RICeE-__- ---- --_- __ASPHAI-T SHiN6LE ROOFINGwTs M t r - --- - -- - RIDGE VENT - W ._ASPHALT SHINGLE ROOFING--_ _- LIJ En RID6E VENT -- -- -- --ASPHALT SHINGLE ROOFING- SE GOND FLOOR PL. HT. FHCD -j El - - - ---_ __ --- -- _ SECOND FLOOR HEIGHTEED � _ _ CEDAR PERFECTION SHINGLES _ Ell 'WITH 5/4 X 4" CORNER BOARDS _ LLJ PERFECTION SHINGLES - _ - EM FM -- -- -- - -- _ _ - AND WINDOW SURROUNDS - - EM WITH 5/4" X 4" CORNER BOA ARDS .. - _- __ - _ _. - - — - _- -- - .. CEDAR AND WINDOW 5URROUND5 - - - J - - --- -_ - - - FLOOR HE16Wu� _ __ FIRST ® I" x 10" BELT BOARD h LLL Or ry 64ZADE Lij w (n z - ---------------------------- O J z ------------------------� O = > I I I i T � 0 Y R AR ELEVATION _ 0 2 SC LE: 1 /4" = 1 '-0" T.O. CELLAR FLR. m - -- - - - - - - - - - - - - - - - - - - - 1 - - - - - - - - - - � - - - - - - - ELEV. a'-I I" 2"x12" RIDGE BEAM <, TYPICAL ROOF CONSTRUCTION ASPHALT SHINGLE ROOFING 12 OVER 15# ROOF FELT ON 1/2" GDX PLYWOOD SHEATHING. 2" x 10" ROOF RAFTERS AT 16" D.G. 12 2"xb" RAFTER TIES O 32 ' O G - 2X4 SILL PLATE ASPHALS FOOT 52"1PLYWOOD 6 - —�XIO R R 16" O.G. - _ 2AO GEILING JOI5T 16" OG. 2xIO R R 16" O.G. b FA5GIA WITH ATTIC 2 VINYL 5OFFIT TYPICAL CEILING CONSTRUCTION TYPICAL CEILING CONSTRUCTION CONT VENTED 2"x10" GEILING JOISTS ® 16" D.G. 2'x10"I GEILING JOISTS ® 16" O.G W/ R-30 BATT. INSULATION. W R-30 BATT. INSULATION. (2) 2x4 TOP PLATE HORI ONTAL VINYL 5101NO GANT O ON TYVEK OUSE WRAP, 1/2" PLYWOOD W 1'- x4 STUDS 16" O.G. z 00D U m ALUM. GUTTER ON _ "xb" FA5GIA BD. _ SECOND FLOOR PL. HT. h z Z Fj Iab" Q J GONTINUOU5 5GREEN VENTQ m I/2" GYP. BD. FINISH T. d 5. 3 GOAT JOB BEDROOM BATH BEDROOM 4 0 m TYPICAL WALL CONSTRUCTION1 7/5"TJI F. JOISTS o 16" OG �33� DETAIL cf) +- CEDAR PERFECTION SHINGLES 3/4" PLYWOOD 5UBFLOOR SECOND FLOOR HEIGHT h 2 n TYVEK HOU5EWSCALE: RAP r_-- - ---- ELEV ID'-O' N. T. S U 1/2" GDX PLYWOOD 5HEATHIN6 _ - _ - -- _. ON 2"x4" WD. STUDS 0 16" O.G. toe R-I5 INSULATION - _ ----`' v 0 Q) n TYPICAL FLOOR CONSTRUCTIONKITCHEN TYPICAL FLOOR CONSTRUCTION _ z DINING ROOM zII 7/b" TJI FLOOR JOISTS ~ 11 7/5" TJ FLOOR JOISTS P AT 6" OG, 3/4" PLYWOOD 5UBFLOOR O AT 16" OG, 3/4" PLYWOOD 5UBFLOORi 11 7/8" TJ / 25 SP 0 16" 0. (f) (� 2" x 6" GGA SILL PLATE, TERMITE SHLD. 3/4" PLYWOOD SUBFLOOR I/2" DIA. ANCHOR BOLTS A7 b' OG W/ MIN. R-19 BATT. INSULATION. FIRST FLOOR HEIGHT �, L L ELEV. 0'-0" 0 x - - 0 U 0 I 8" POURED CONCRETE FOUNDATION WALL WITH 2 - N 5 BARS TOP AND BOTTOM 3" DIA. STANDARD WEIGHT 1 ON A 10"x20 POURED CONCRETE FOOTING. CELLAR STEEL PIPE COLUMN WITH 2 - # 5 BARS ON A 30" x 30" x 15" 4" POURED ONGIRETE SLAB H No. POURED GONGRETE 4 MILL JAPOIR BARRIER FOOTING. (TYP.) 2 SECTION I CELLAR � _ ELEv. -a'-u' 2 SCALE: 1 /4" = 1 '-0" OF 5 Qw=�• yr s 95,_0„ 26,_0„ E O 23,_6„ 21,_0„ 4, 4„ F - - - - - - - - - - - - -- -1 I a z ry j • � Un 00 o_ - - - - - - - - - - Ld - - - - - � m � I �- - II II l i a LINE OF LL/ I 'c LINE OF WALL I UHI L - - - -- - - -- - - - -- - - - - -- - I I I o 0 ILL F L - - - - - - - - - - - - - - - - - - - - rzErE� ' A VE ABOVE I I N Z 5" POURED GONG 0 p ® IIF IIS- DOUBLE UP ISLAND O ro - CD AA I I�'1 N - FOUNDATION WALL ON 8"X16'1 H3AUD9 `t O Q POURED CONCRETE FOOTING m > N UNEXCAVATED N Z - h , III w Q p COMPACT 4 FILL m � IIIA III HAJ2 .QHCIO 9 1 \j - ,p01 4" P G. SLAB F" 1 `-r 1�= 1= Z (3 ryWITH6X6 / IOXIOKKMgm - I IX IIx 3 1/2" STANDARD STEEL r P .p iim F' z I I� 1—PIPE COLUMN ON A �{� �v IIn� I 30'X30"XIS"TEEP POURED o 7 „ 0, 0 GONGREIO FOOR( O" 8TMP) 4 8'-10" 8'-10" Lc N O by I ro 1 BEAM P KET (- r r r 7 r I� H 1 1 Q ��_ i - _ 3- 3 4" 11 l/8" ML. GIRDER '�� - - ��I�I v L - - - - - -�' J r r - BOILER - - L _ J L J x - J L _ J L11J W U lJx - yy�� ,yo U Q LINE OF KALI-/ I r IN LINE OF HAL m I IW H 8" POURED CONCRETE Q p v ABOVE 1 - ABOVE IIT - FOUNDA ION L ON " - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J- 9/R s II" 6 POURED_TG_ONG_REL_TE_FOOTING N -� �I 3M . GIRD 4' 0 N p 14,_0„ 18'_0" [� Y (3)-2x10 GG4 - " W r - - - - - - - - - - - - - - - - J " o W O H r - - - - - - - - - - - - -- -- - - - - - - - W w F = �� z v ml IIx ? I O J �I v T- 7 C w XII = LINE OF WALL im - - Q > _ III X ABOVE III T 0 Q I I 14,_0" 3'_4" 7 " � � Y mll m p ryl T = Q- L —_ - - - - - - - - - - - , " r - - - - � - - - � m I L - - L - - - - - - -J - I - - - - - - - - - _ - p `{ GOMPAGT - to 4 FILL L - - - - - - - o I I � I p - I L L 26_0" 9'-0" 14'_6„ 3'-6" 8'-2" 2'-b" 9'-O" It 2'-6" 181_6" 95'-O" 1 `I GENERAL NOTES w a FOUNDATION PLAN D 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS TO THE SITE 15. MAINTAIN2" MINIMUM CLEARANCE BETWEEN ALL STRUCTURAL FRAMING 3 / SCALE' 1 �4� = 1 -� PRIOR TO STARTING OF WORK AND HE SHALL FAMILIARIZE HIMSELF WITH 27. PLYWOOD DECKING SHALL BE EXTERIOR GRADE PLYWOOD WITH EDGES MEMBERS AND FIREPLACE OR CHIMNEY MASONRY. Z O THE INTENT OF THESE PLANS AND MAKE WORK AGREE WITH SAME SOLID BLOCKED OR PLY CHIPS. 16. ALL FLOOR JOISTS SHALL BE LATERALLY SUPPORTED BY BRIDGING OR F-Q GO 2 CONTRACTOR OR OWNER SHALL OBTAIN A BUILDING PERMIT FROM THE BLOCKING ®INTERVALS NOT EXCEEDING EIGHT FEET. 28. ALL STRUCTURAL STEEL SHALL BE A-36 STEEL AND SHALL BE Q m _ 1p' TOWN OR VILLAGE PRIOR TO STARTING WORK INSTALLED AS PER A.I.S.C. p 17 ALL FLASHING SHALL BE ALUMINUM 29 ALL DRYWALL SHALL BE U.S.G. NATIONAL GYPSUM CO. 1 2' THICK, 3 CONTRACTOR SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, / CERTIFICATES OF OCCUPANCY. INSPECTION APPROVALS, ETC, FOR WORK 18. ALL RAFTERS SHALL BE ANCHORED TO FRAMED WALLS WITH "HURRICANE TAPED AND SHACKLED THREE COATS, RIDGE VENT PERFORMED FROM AGENCIES HAVING JURISDICTION THEREOF. CLIPS" ®16" ON CENTER. SHINGLE RIDGE CAP 30 ALL DRYWALL SHALL BE PRIMED AND PAINTED (2 FINISH COATS). 4. ALL WORK SHALL CONFORM TO THE NEW YORK STATE UNIFORM FIRE 19 ALL INTERIOR DOORS SHALL BE STAIN GRADE 6'-8" HIGH X 1-3/8" J NOSS pP PREVENTION AND BUILDING CODE AND ALL RULES AND REGULATIONS OF THE THICK X WIDTH AS NOTED ON PLAN NTH APPROPRIATE HARDWARE ALL 31. ALL MOLDINGS AND TRIM SHALL BE STAIN GRADE, AS SELECTED BY TOWN. 0p DOORS SHALL BE FINISHED AS PER OWNER. SHINGLES 5 IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS WHICH 32 ALL FINISHES (INTERIOR AND EXTERIOR) SHALL MATCH EXISTING AS co I FELT PAPER \' ROOF SHEATHING IF, P.) 2D. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SU FOR SCALED n DISAGREES WITH THAT AS INDICATED ON THESE PLANS, THE CONTRACTOR DIMENSIONS. ARCHITECT HAS NOT BEEN RETAINED FOR ON SITE CLOSE AS POSSIBLE � ^ SHALL STOP WORK AND NOTIFY THE ARCHITECT. SHOULD HE FAIL TO INSPECTIONS AND/OR OBSERVATIONS OF THE CONSTRUCTION -F-� FOLLOW THIS PROCEDURE, AND CONTINUE WITH THE WORK, HE SHALL 33. CARPETING SHALL BE SUPPLIED AND INSTALLED BY THE OWNER. E io ASSUME ALL RESPONSIBILITY AND LIABILITY ARISING THEREFROM. 21 DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND RAFTER SHALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT 34 OWNER SHALL SELECT ALL COLORS. O U n 6 GRADING AROUND NEW CONSTRUCTION SHALL SLOPE AWAY AND BLEND INTO FOR WHICH THEY ARE MADE IS EXECUTED OR NOT, THEY ARE NOT TO BE EXISTING. USED ON ANY OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT 35. ALL PLUMBING SHALL BE IN STRICT CONFORMANCE WITH NEW YORK BY AGREEMENT IN WRITING AND WITH ADEQUATE COMPENSATION TO THE STATE BUILDING CODE, THE NEW FIXTURES INTO EXISTING SANITARY �- 7 ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL WITH A MINIMUM SOIL ARCHITECT. SYSTEM. -F--� i PRESSURE OF 2 TONS PER SQ FT AND SHALL HAVE A MINIMUM OF S-0" OF COVER 22. PATCH AS REQUIRED ALL AREAS WHERE [EXISTING HAS BEEN REMOVED 36 CONTRACTOR SHALL DETERMINE WHETHER THE EXISTING ELECTRICAL •_ RIDGE BEAM AND/OR NEW WORK ABUTS EXISTING WHERE EXISTING WALLS ARE REMOVED SERVICE IS SUFFICIENT TO SERVICE THE NEW ADDITION AND SHALL 8 ALL CONCRETE SHALL BE 2500 PSI CONCRETE ®28 DAYS, OR NEW OPENINGS ARE CALLED FOR IN EX(ISTNG WALLS, PRIOR TO NOTIFY THE OWNER ACCORDINGLY ALL ELECTRICAL WORK SHALL BE BOARD N REMOVAL Of EXISTING WALLS, CEILING BEAMIS, ROOF RAFTERS, ETC, OF FIRE UNDERWRITER APPROVED INSTALL AS PER OWNER'S DIRECTION (n w 9. DESIGN LOADS: FIRST FLOOR - 65#/SF LIVE LOAD CONTRACTOR SHALL BRACE EXISTING AS REQUIRED UNTIL NEW HEADER AS ANY AND ALL INTERCOM, TELEPHONE, AND/OR N ANTENNA WIRING IN ROOF - 50#/SF - LIVE LOAD SPECIFIED IS INSTALLED. WALLS PRIOR TO INSTALLATION OF WALLBOARD. ALL TEMPERATURE U SECOND FLOOR - 50#/SF LIVE LOAD CONTROL WIRING SHALL RUN CONCEALED IN WALLS, FLOORS, AND/OR L n RIDGE VENT CEILING - 30$/SF - LIVE LOAD 23 CONTRACTOR SHALL REROUTE AS REQUIRED ALL EXISTING PLUMBING, CEILINGS. VERIFY OUTLET, SWITCH AND LIGHTING LOCATIONS WITHELECTm 2 R D V V T DETAIL 0. DESIGN TIMBER STRESS - DOUGLAS FIR SOUTH, N0. 2 GRADE FB = NTH NREW CONS RUOTON AIR-CONDITIONING, AND HEATNIG LINES WHICH INTERFERE OWNER PRIOR TO INSTALLATION. _c x `.J 825 PSI, E = BER ST00 P51. 37. DOUBLE JOISTS UNDER ALL PARTITIONS PARALLEL TO FRAMING AND m 24 ALL "MICRO=LAM" LAMINATED VENEER LUMBER TO BE DOUGLAS FIR AS PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS. U a IT ALL HEADERS SHALL BE (2) 2"X8" IN 2'X4" WALLS k (3) 2"X8" IN MANUFACTURED BY TRUS JOIST CORP. OR EQUAL. SIZES AS INDICATED ON 38. THE CONTRACT DOCUMENTS GENERALLY INDICATE THE SCOPE AND QUALITY 2"X6'• WALLS UNLESS NOTED OTHERWISE. PLANS MICRO-LAM INSTALLATIONS SHALL BE IN STRICT CONFORMANCE WTH MANUFACTURERS SPECIFICATIONS AND 6RECOMMENDATONS. OF THE WORK, BUT ARE NOT PRESENTED AS BEING FREE FROM ERRORS OR 12. ALL HEADERS SHALL BEAR ON 4"X4" POST ® 2'•X4" WALLS OR 4'X6" OMISSIONS, AND ANY WORK CALLED FOR IN THE SPECIFICATIONS AND NOT SH T. N O. POST ® 2'X5' WALLS UNLESS NOTED OTHERWISE 25. ALL METAL JOIST HANGERS AND OTHER MIETAL CONNECTORS REQUIRED SHOWN ON THE DRAWINGS AND NOT CALLED FOR IN THE SPECIFICATIONS IS TO SHALL BE "TECO CONNECTORS" OR EQUAL AND SHALL BE CAPABLE OF BE PERFORMED AS IF THE WORK WAS CALLED FOR IN BOTH. ANY AND ALL 13 FURNISH AND INSTALL SINGLE STATION SMOKE DETECTING ALARM HANDLING LOADS ® CONNECTION POINTS INSTALLATIONS SHALL BE IN WORK AND ANY AND ALL MATERIALS NOT LISTED IN THE BID DOCUMENTS THAT DEVICE IN COMPLIANCE WITH NEW YORK STATE BUILDING CODE. STRICT CONFORMANCE WITH MANUFACTURERS SPECIFICATIONS AND ARE REQUIRED OR CAN BE REASONABLY OR NORMALLY BE INTERPRETED OR RECOMMENDATIONS. INFERRED, THEREFORE, SHALL BE FURNISHED AND INSTALLED BY THE 14 ALL WINDOWS SHALL BE WHITE PERMA-SHIELD WITH HIGH PERFORMANCE CONTRACTOR GLAZING AS MANUFACTURED BY ANDERSEN WINDOWALLS OR EQUAL, INCLUDE 26 DOUBLE JOISTS UNDER ALL PARTITIONS PARALLEL TO SAME AND AROUND INSECT SCREENS AND JAMB EXTENDERS AS REQUIRED. ALL OPENINGS. OF 5 C D srq o. 0 y OF 0 z 0 W U cf) N (51-71. 13'-T1 101, 6'-6" 6_51. 7'-4" 2x52 3 2-2"xl2" HDR 2- "xl2" H -__- WOOD 5TEP5 O GRADE m p 125 CFM EXHAUST LL�I O FAN TO EXTERIOR FWG I II-4 3 - 2010 2 \ 'I INTERIOR TYPE "X" GYP. BOARD AND I, Ln _ _ _ _ _ _ _ _ _ _ __ _ 99 ;p INTERIOR GARAGE WALLS AND r CANTILEVER ABOVE CEILING. 2032 032 _--- UPSET IHTOIFLOOR lOI5T�5 - - -J 2 - • o o L- - _- - Oi - p W 2-2"xl2" HDR. 2-2"xl " HDR. WOOD STEPS O 64ZhDE in Q ~ O 1' 29'_10" VENT RANGE ? 2 PRE FAB METAL FLUE W AarH T 11�' o GARAGE rHrzuRooF li PANT Y NOOK ovrslDE Fm 2552 1z X -X J 4- POURED GONG. GC D 7b70 9'-0' CEILING 2b52 xl2" HDI -- _ _ 1 � LAUND I BATH : 'I _ _ Q F O ° - - 11�1� _ _ 2' x I2 HEADE� w rr � m - 41R 5,_2A LAND O O I L- 2-2°x12" HDR V / � N Z9 3 1/2" STRUGTRUAL - ® STEELCOLUMN TO - _-= SCEp AR ti� �Lg My.�"iN�.1FCT - - - - - - - 2 2 - - - - - - - � 26'_6" `fl GTN 28 + ?� a'-O" 25 GFM FjfFIAUST T4X 0240 y0 JN TO EXTERIOR _ _ 9r F N _ _ - _ N 2" 10" RRL 2" X 10" R. (2J 2 r -Q \} \ 2 � LL - - - - - - - - - • 12' Io" ° � - - -- (2) 2• xI0• (2) 2' ¢ 10• n ry N / ° BEDROOMtbi BEDROOM zo ° 2 X Rl \ a / - d m d O 8'-0' GEILIN6 IN ATTI / &-0• GEL1Ne � � wxa/4' PLYwooo ? om/ 2 _ RRry FR,ArE 2 x 4 o4ALLs aWAr 4'-0AeavE L00R BATH . r. . = s'-e^ o- - - 8'-0' CEILIImSMOKEMOKE 2• x a• RR 16• a 6 a 1 W I CLOS ° DETECTORECTOR TYP DORr�R FRAM e, ° C 125 CFM ExHAVST roR 0 0 0 AN TO EXTERIOR � - --ry2 X 12 RI � 206 -- 268 � - - - - - - - - ° 5'_6" ( r/, '.BATH O 6 0 o \ \ 2 - RR DETELi CTOR ° BATNFANq v v e., m o a o e'ta•ern n+5 -rcv � ml 2 x w v v < ® x = s ]'x12 MAIN R DEE , a - L- L± III CLOS _ - - - -- - xcuE✓2� W1#2 - � ry \� _ HALL =---- _ _-=_ FAMILY ROOM ROOF Lry x la° R.R. r x I011oLq* BBLow - / \ t' o' - - - - - / I 2' N 2" ® O I O G LAR ® I6" O.C. \\ \\ i ' k '" .' 51 DETECT SLD6068 1 W Q \ 2668 32 I I MASTER BEDROOM TRAY GEILIN6 - - - _ -_ - - - - \ OPEN TO 2852 z o I a'_2" BELOW g.. T - W L - - - - - GTN 2B FRAME THIS DO - _- - - - - - Q 111 ° m GEILIN6 ° ;q 8'-0DROOIM d `L _ �- tAL 11. TIMER H TH 5EE FRONT ELEVFIT ON = N ;p O aX O IN W L O r X m ® ry I ®N ry � 3 LLJ ry 2-2 xl2' HDR. 2-2"x12" HDR. x Io' R _ 6 0 J Z r - - - - - " O:R.R. - 2-2"x12" HDR. - _ 2_2"x l2 1 m m i, / •2 52 _- - 28 2 -\ / • Ib" o.G o / \ 28 2 _ _ _ _28 HDR.- 0 = W 2 O Q L _ SUMMARY OF TOTAL THERMAL RATING c o IF THE TOTAL. THERMAL RATING IS ZERO (0) OR GREATER, THE = o PROPOSED DESIGN FOR THE BUILDING ENVELOPE COMPLIES W/ I- m THE ENERGY CODE. THERMAL TABLE Q FLAT FRAME REVER5E THSU AND AREA U-VALUE RATING USED //yy LAYOVER MAIN ROOF LL_ 51N6LE PLY RUBBER ROOFIN& TRAY CEILING IN AA5TEF BATH A. WALL ASSEMBLY CD AT 12'-0" ABOVE FIN I LOOK Al. NET WALLS 2.690.20 ' .07 +233 6-1 A2. GLAZING 439.80 ' .32 -70 6-1 A3. DOORS 80.00 ' .07 +7 6-1 SUBTOTAL THERMAL RATING FOR SECTION A (A7+A2+A3) +17 B. ROOF/CEILING ASSEMBLY 6'-5" 8'-I" l'-O" 3'-9" 01. ROOF/CEILING 2,813.0 ' .046 0 6-3 B2. SKYLIGHTS .42 6-3 1 L O O R PLAN A N 4I 6 SECOND SUBTOTAL THERMAL RATING FOR SECTION 8 (B1+B2) 5 SCALE: 1 /4" = 1 '-0° SECOND FLOOR LIVIf, G = 1468 SQ.FT 1 4' VENT 4' VENT C. FLOOR ASSEMBLY o 0 iHRN ROOF IHRU ROOF Cl. FLOOR 2,813.0 ' .046 0 6-3 w ~ N / PTYP m z Id ( ROOF C2 FOUNDATION WALL O 0) I. 1 WALL PERIMETER 0 " b ", (2' 2 / I ABOVE GRADE EXPOSURE SBS W Z .F 2- 1- _ INSULATION DEPTH ~ Q m U VALUE CALCULATIONS l a r p 2'V �I\'V r r I j _ , 24' 48• o 0 0 v� I 1V•vl o I �r2'v I ur ROOF/CEILING MLLa cc ttL 84• FOOTING I/S b t( I �'I I 901 I 1 � \y �I\V OUTSIDE AIR FILM R = .17 OUTSIDE AIR FILM R = .17 / I' \'l PERIMETER R-VALUE u EXISTING I IWC. LAV i �I\"V I W.C. i NV IAV C3. SLAB EDGE INSULATION ASPHALT ROOF SHINGLES R = .44 CEDAR/VINYL (AVERAGE) R = .69 HOUSE I SNB I ° 1 I I I IUB 1 15/ FELT R = .06 TYVEK R = •� I I I I ILTJ SECOND SUBTOTAL THERMAL RATING FOR SECTION C (C1+C2+C3) 4"'P \• PLYWOOD SHEATHING R = .62 PLYWOOD SHEATHING R = .45q' I q• I\• -M. TOTAL THERMAL RATING 6• BATT INSULATION R = 19.00 3 \' BATT INSULATION R = 13.00 2' I I\' 2' 1 Y CO. E nnfTm U m (FOIL FACED) (FOIL FACED) I + 170 O.K aoOv I 0 Q) n \' GYP. BD. WALL BD. R = .43 \' GYP. BD. R = .68 a mMaAFMEE k P MIM � - I •- INSIDE AIR FILM R = .68 INSIDE AIR FILM R = .68 / , �r--I\'V �2 V 1 I .v �-I\'V �"� 93% TOTAL R 0 CAVITY R = 21.40 U = .05 85% TOTAL R O CAVITY R - 15.73 U = .07 �' (2)2-W TOP PUM I � H I I 7% TOTAL R 0 RAFTER R = 11.46 5% TOTAL R O STUD R = 9.35 / a i IAV I I WASHER SINK I SINN o o FlOOR INH A D SPACE / WE I I a I ° 0 INSIDE AIR FILM R = .68 �, \' FIRST PLYWOOD UNDERLAYMENT R = .62 \• PLYWOOD SUBFLOORING R = .76 I\. I\' F-R' m C.O. x 0 STILL AIR SPACE R - .62 5 \- BATT INSULATION R = 19.00 HURRICANE T AS C. PIPE PITCHED a STILL AIR FILM R = .61 2 U R R I C A �� E CLIP D E I AIL F A.I. & SANITARY SYSTEM AS PER N Y S CODE 93% TOTAL R 0 CAVITY R =22.65 U = .05 = SHY. No. 7% TOTAL R O JOIST R = 12.66 5 SCALE. N . T.S. 2 PLUMBING RISER DIAGRAM 5 SCALE: N.T.S OF 5 I