Loading...
HomeMy WebLinkAbout30016-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-29966 Date: 01/16/04 THIS CERTIFIES that the building CHIMNEY Location of Property: 445 BURTIS AVE SOUTH/PEC (HOUSE NO.) (STREET) (HAMLET) County Tax Map No_ 473889 Section 67 Block 4 Lot 18 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JANUARY 9, 2004 pursuant to which Building Permit No. 30016-Z dated JANUARY 16, 2004 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is INSTALLATION OF CHIMNEY AS APPLIED FOR. The certificate is issued to STEPHEN & PHYLLIS C. GRANDE (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HRALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO_ N/A PLUMBERS CERTIFICATION DATED N/A P ho ized Signature Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 30016 Z Date JANUARY 16, 2004 Permission is hereby granted to: STEPHEN & PHYLLIS C. GRANDE 8 DRIFTWOOD DR PORT WASHINGTON NORTH,NY 11050 for INSTALLATION OF CHIMNEY AS APPLIED FOR. (THIS REPLACES BP #19473-Z) at premises located at 445 BURTIS AVE SOUTH/PEC County Tax Map No. 473889 Section 067 Block 0004 Lot No. 018 pursuant to application dated JANUARY 9, 2004 and approved by the Building Inspector to expire on JULY 16, 20 Fee $ 150 . 00 i Author' d Signatur ORIGINAL Rev. 5/8/02 FoRk No. $ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, N. Y. BUILDING PERMIT n (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) W 1947.3 Z Date .......4&� .......�.`j.......... Permission is hereby granted to: :. s...k ... , .... ............ to . ..... ... c. :....�.... ...... ........................... .............................................................................. .. . ... .. .e ........ .... .. . ... at premises located at .... .... ....J... .°1_ .........J.... ... :. ...................... ::::: :::.. :::: Q:�: ... ......... . :......... :::::::::::::::::::::::::::::::::::::.... .:::::::::::::::::::::: ::::::::::::: County Tax Map No. 1000 Section ..,�. b ......... Block ......®. ....... Lot No. -13.............. pursuant to application dated ....Q. >'� ,...A7.1.................... 193JR, and approved by the Building Inspector. Fee S. S:../... 1e ? .... .. ... ....Y...CZ,t...... Building Iraspeator Rev.,6/30/80 Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect;I engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool $25.00,Accessory building$25.00,Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. 1 /20/04 New Construction: Old or Pre-existing Building: X (check one) Location of Property: 445 Burtis Place, Peconic, NY 11958 P y� House No. Street Hamlet Owner or Owners of Property: Robert Phillips and Jenny Phillips Suffolk County Tax Map No 1000, Section 67 Block 4 Lot 18 Subdivision Filed Map. Lot: Permit No. 30016-Z Date of Permit. 1/16/M Applicant: Paul A. Caminiti Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: X (check one) Fee Submitted: $ nn Applicant Signature C-0 a,29 q �� FIE LD I;:SPECTiU:! DATE ^uMMENT� 1 H FOUNDATIONrp c N FOUNDATION? ( 2nd ) _ m z 0 c ROUGH FRAME & xr, PLUMBING 3 . x m I77SULATIOPI PER N. Y. y � R STATE ENERGY CODE x �.V r 4 . m H FINAL qo s z 3 ADDITIOAIAL COMMENTS : m X H O `O Z m a r 0 m t� �I1 TOWN OF SOUTHOLD PROPERTY RECORD CAR® � OWNER STREET VILLAGE DISTRICT SUB. LOT FORMER OWNER N E ACREAGE 1._ o z7 S W TYPE OF BUILDING /( RES.Z /p SEAS. VL. FARM COMM. IND. CB. MISC. LAND I IMP. TOTAL DATE REMARKS Aa i>A5 _ I C L 0 C` l� f" '7 9 l .t J ( rl �o_.� ?�' .. )'�"._. �7 '✓^��_. �.l^'' � �<', r�i h�Cr "=",:- k � a- r ,..., , AGE �A_ —BU1 DUNG A T Nda_ NEW NORMAL BELOW ABOVE Farm Acre Value Per Acre Value Tillable 1 Tillable 2 Tillable 3 Woodland Swampland B rushland House Plot. _ Tota l I Y 1 M _ Y — Aa AryM' I , j /,k7-'y -� M. Bldg. ? a �. t� b j Gi 1� 5C) Foundation C- Bath ! —Ti Extension xJ / y6 Basement Floors /C, a aY ,fes fa YO7" - - - Extension / `, < - rre,. Ext. Wallst Interior Finish ! Extension Fire Place Heat Porch Attic Porch Rooms 1st Floor Breezeway ;Y J / N , / � /�-- Patio Roor��2nd-Floor Garage 17 y Driveway - --- -- BOARD OF HEALTH . . . . . . . . . . . 3 SETS OF PLANS . . . . . . . . . • . FORM NO. 1 SURVEY . . . . . . . . . . . . . . . . . . . . TOWN OF SOUTHOLD CHECK . . . . . • . . . . . . . . . . . . . . . BUILDING DEPARTMENT SEPTIC FORM . . . . . . . . . . . . . . . TOWN HALL SOUTHaLZ,U.G_1 `1121 N�FIp1 s TEL.: 765-1802 CALL . . . . . . . . . . . . . . . . . . . . . Q MAIL TO : Examined .Q �" �. • �.�., 19 9.4� Approved .4? . ., 19 R,O, Permit No. �.`� �d . . . . . . . . . . . . . . . . . . . . . Disapproved a/c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Building nspector) APPLICATION FOR BUILDING PERMIT Date . /7----- - - I5�©. INSTRUCTIONS a. This application must be completely filled in by typewriter or in ink and submitted to the Building limper-tor,with sets of pians,accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public street, or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this appli cation. c. The work covered by this application may not be commenced before issuance of Building Permit. -d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of Occupancy shall have been granted by the Building Inspector. APPLICATION IS HEREBY MADE to.the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspe _tons. . . (Sign/atu applicant, or name, if a corporation)// (Mailing address of ap t) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder. . . . . ... . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . ..._. . . . . . . . . . . . . . . . . ..... . ... . . . Name of owner of premises . . . . . . e . . . . . . . . . (as on the tax roll or l e,ft� o tent r v If applicant is a corporation,signature of duly authorized officer. DATE 0 ® B P '1 eFr. r ,. . . . . . . . . �. . . . . . . . . . . . . . . . . . . . ...-. . . . �. . . . . _ EE: !SY T" nEPARTrv1ENT 9 !. Name and title of corporate officer kvCSTgF B�." ebb;C G�'. FOR THE TR5-$�St32 S A. r � � Builder's License No. ... . ....... .. . . . . . . . . f'"LC . . . . . r(,R PORE—.,Ck^.t C.R5PLUM� BiNG Plumber's License No. . . . . . . . . . . . ZING ,_ LU 2. hi sOti • Fl�.�tf4 - jNSULATIO!" Electrician's License No. . . . . . . . . . 3 a, F621AL r a"iS"+RUCTION MUSS - mCi SHALL Other Trade's License No. . . . . . . . . . . . . . . . . . . . . . „ BE C€ MPLcT Tla lOTtO�R FOR t .63, MEET ALL GD'1 THE REQUIREMENTS OF THE �'Y- 1, Location of land on which proposed work will be done'. Sf�fE CO, 9TRUCTION & E�EBC'y � .. . . . CODES. T REB'R3�tON E FOR . . . . .I. . .ERRORS House Number Street, Hamlet County Tax %lap No. 1000 Section . . . . . �'z. • • . . . . Block . . . . . . . • • • , • • , • • , Lot . . . . . . . . . . . . Subdivision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filed Map No. . . . . . . . . . . . . . . Lot . . . . . . . . . . . . . . . (Name) ' State existing use and occupancy of premises and intended use and Occupancy of roposed construction: A. Existing use and occupancy. . • • "" ' 5q+ 14 m B. Intended use and occupancy. . . . . . . . . . . . . • a air 3. Nature of work(check which applicable): New Building . . . . . . . . . . Addition . . . • • . . • • Alteration . . . . . . . . . .. . Repair . . . . . . :. . .'. Removal . . . . . . . . . . . . . . Demolition . . . . . . . . . . . . . . ScSi:ncting pool. Tennis Court Accessory Building. . . . . . . . . .Fence . . •Other Work. 4. Estimated Cost . . . . . "..° . . . . . . . . . . . . . . . . . . . . . . . Fee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . • • •/• • . . (to he paid on filing this application] S. 'If dwelling,number of dwelling units . . . . . . . . . . . .. . . Number of dwelling units on each floor. . . . . . . . . . . .. . . . • Ifgarage, number of cars . . . . . . • • • • • • •• " ' ° " '• " . . .. . . • • • 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use . . . . . . . .. . . . . . . . . . . . . . 7. Dimensions of existing structures, if any: Front . . . . . ... . . . ... . . . Rear . ... . . . . . . . . . . . Depth . . . . .. .. . . . . . . . . Heialit . . . . . . . . . . . . . . . Number of Stories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . Dimensions of same structure with alterations or additions: Front . . . . . . . . . . . . . . . . . Rear . . . . .. . ... . . . . . . . . . Depth . . . . . . . . . . . . . . . . . . . . . . IIcight . . . . . . . . . 0 . . . . . . . . . . . .Number of Stories . . . . . . . . . . . .. . . .. . .. . . . 8. Dimensions of entire new construction: Front . . . . . . . . . . . . . . . Rear . . . . . . . . . . . . . . . Depth . . . . . . . . . . . . . . • Height . . . . . . . . . . . . . . .Number of Stories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . . . . . . . . . . . 9. Size of let: Fiont .. . . . . . . . . . . . . . . . . . . . . Rea! . . . . . . . . . . . . . .. . . . . . . . Depth , 10. Date of Purchase . . . .. . . . . . . . . . . . . . . . . . . . . . . . . Name of Former Owner . . . . . . . . . . . . . . . .. ... . . . ... . . . 11. Gone or use district in which premises are situated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12. Does proposed construction violate any zoning law,ordinance or regulation: . . . . . . . .. . . . . .. .. . . . . . . . . . .. . . . . . 13. Will lot be regraded . . ..... . . . . .. .... . . . .. . . . . . .Will excess fill be removed from premises_ Yes ..., No. 14. Name of Owner of premises ... .. .... .. ... ......Address ............. . ... ..Phone No. . . . .... . .. .. . . . Name of Architect . . . . . . . . . . . . . . . . . . . . . . . . . . .Address . . . . . . . . . . . . . . . . . . .Phone No. . . . . .. .. . ... .. . Name of Contractor . . . . . . . . . . . . . . . . . ... . . . .. . .Address . .... . .. ... ....... .Phone No. . . . . . . . .. .:. . . IS-La this property located within 300 feet of a tidal wetland? *YES. . . .NO. . . . *If yes , Southold Town Trustees Permit may be required. PLOT DIAGRAM Locate clearly and distinctly all buildings, whether existing or proposed, and-indicate all set-back dimensions from property lines. Give street and block number or description according to deed, and show street names and indicate whether interior or corner lot. STATE OF ti -YOR r t�F ,l '4�.S:S COUNTvv !_ : 4 .C,. . . � • ... .. . .. . . . . . . . . . . . . . . . . . . being duly sworn, deposes and says that he is the applican (Name o individual signing contract) above named. He is rhe'. . . . . .. . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . : . . . . . . . . . . . . . . . . . .. . (Contractor,agent, corporate officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file thi application: that all statements contained in this application are true to the best of his knowledge and belief;and that th. work will be performed in the manner set forth in the application tiled therewith. Sworn to before me t1pis . . . . . . . . . . . . YC day of 19 L.� Notary Public, County n i -- CLAIRE L GLEW a. . . . . . . . . . . . . . Notary Pubft State of NowYalt No.4879 /.', (Signature of applicant flualified in suffak County COaxnlssiot►EtrpN�f 8,19 P-C R C FLASHING u A SDP-TF DCR-TF B COLLAR D B SC.DCR-S WALL STRAP � C SDP-WS.OCR-WS- 2i . MIN. E ) ) CHIMNEY ® �_ DURA-CHIMNEY SECTION 2 In. 50 K.MAX. MIN. D SDP-P DCR-P 2 in, DURA-PLUS E y IMIN. F CZD� � E 35 H.MAX. � � TEE D 7 DI SDP-T DCR-T CHASE 18 in.MIN. G ENCLOSURE 18 in.MIN. TEES PORT BRACKET H F S -TS,DCR-TS F H N TEE CLEANOUT G G ACCESS DOOR WALL THIMBLE SDP-WT,DCR-WT b, Figure 15. NEVER INSTALL SINGLE WALL STOVEPIPE IN THE WALL t WALL THIMBLE THIMBLEI DCR-WT.SOP-WT S. Install Tee Support:Remove the two screws from the Tee Cleanout Cap and detach.Level the Tee Support Bracket so it OUTSIDE (INSIDE holdsthe Too 3-inch ally long lag screws.At tachs base the wall with TeeSup our rt APPLY MASTIC 'I WALL I $/16-Inch,3-inch long lag screws.Attach the Tee Support Straps to the base with the nuts and bolts provided.Use two CHIMNEY5/16-inch,3-inch long lag screws to attach the straps to 1 SECTION in the wall.Replace the Tee Cleanout Cap and screws once the GALVANIZED j DCR-P, BLACK Tee Is Installed. SECTION I SDP-P SECTION S. Complete Chimney:Attach Chimney Sections as in Step 7 and Figure 7 of the Coiling-Supported Installation section. FLANGE WALL ~FLANGE Secure the chimney to the wall with Wall Straps at 4-foot PIPE SECTION intervals to maintain at least 2 inches of clearance to com- bustible materials. Slip Wall Straps around the chimney,tighten the bolts,and Figure 16.Wall Thimble fasten the straps to the wall with two 5/16-inch,3-inch long lag screws,on each side.Snap the Chimney Cap into the top of the chimney once it is the height specified in Figure 1. 4. Seal Outside:From outside,insert the galvanized pipe If the chimney penetrates an overhang,frame for at least section of the Wall Thimble through the wall and into the 2 inches of clearance and install a Flashing and Storm Collar black section.If it does not reach the black section,an exten- as described in Steps 9 and 10 for Coiling-Supported Instal- / sion tube can be made locally from.Ot&inch galvanized steel. ladons.See Figure 17b.Another option is cutting away the Seal the flange to the outside wall with non-hardening water- overhang for a 2-inch clearance as in Figure 17a. proof mastic and fasten to the wall with screws.See Figure 16. Slip the Chimney Section, attached to the Tee, into the If the chimney extends more than 4 feet above the top Wall Thimble. Band or a Flashing use an Extended Root Support. 9 J Dura-Chimney(DCR)•Dura-Plus(SDP) Installation at on & Operation Instructions , CHIMNEY MAINTENANCE A MAJOR CAUSE O F CHIMNEY Creosote and Soot—Formation and Need for Removal: 4. Coal—To reduce corrosion in chimneys where coal is When wood is burned slowly, it produces tar and other burned,down the stovefortheseason.CheCkthechimney's clean the chimney thoroughly within 48 hours of RELATED FIRES I S FAILURE TO moisture to shutting organic vapors,which combine with expelled � form creosote.The creosote vapors condense intherelatively lining for sulfuric acid corrosion regularly. cool chimney flue of a slow-burning fire.Asa result,creosote 5 Chemical Cleaners Do not use chemical chimney MAINTAIN REQUIRED residue accumulates on the flue lining.When ignited,this cleaners.Their use does nott eliminate the need for mechani- creosote makes an extremely hot fire. cal cleaning and they may be highly corrosive. Chimney Cleaning: 6. Case of Fire a flue fire occurs,close all appliance CLEARANCES (AIR SPACES) T O draftft c openings and callll your Fire Department.Do not use the 1. Access—Chimneys must be installed so that access is chimney again until it is inspected for possible damage. provided for inspection and cleaning. COMBUSTIBLE MATERIALS. I T I S 7. Chimney Protection—Painting.To increase chimney life, 2 When to Clean—The chimney should be inspected at coat all exterior metal parts with high temperature rust-proof least once every month during the heating season to deter- paint.This is highly recommended,particularly in areas near mine if a creosote or soot has built up.Check spark arrestor the ocean.Wash the metal with a vinegar and water solution O F THE U P h�!O ST IMPORTANCE screens every 2-4 weeks.If creosote or soot has accumulated, before painting. it should be removed to reduce the risk of chimney fire. 3. leaned by a proles_ THAT THIS CHIMNEY B E profes- sional nal chi Clean_Have your chimney chimney sweep if you have doubts about your ability to clean it.Use a plastic,wood,or steel brush.Do not use a brush that will scratch the stainless steel liner of your chimney. Scrub the spark arrestor with a wire brush. warranty—Simpson Dura-Vent warrants Dura-Chimney and INSTALLED ONLY I N Dura-Plus for a period of 25 years from the date of installation. To remove the Chimney Cap for cleaning,unscrew the four The Warranty includes all component fittings except chimney screws that attach the cap's support legs to the cap base.The tops.For specific details,see the printed Warranty included ACCORDANCE WITH THESE Tee Cleanout Cap can be removed once the screws are in the Chimney Catalog. DURA-VENT, DURA-CHIMNEY, unscrewed.Remember to replace the screws when you are DURA-PLUS and DURA-BLACK are the registered trade done cleaning the chimney. marks of Simpson Dura-Vent Corporation. INSTRUCTIONS, Table 7 Read through all these instructions before beginning your installation.Failure to Install the chimney as described in these Instructions will void the manufacturer's warranty and may have an effect on CATALOG NO. DCR6 DCR-P 7 DCR-P a DCR-P 10 DCR-P your homeowner's Insurance and U.L.listing status.Keep these instructions for future reference. SDP a SDP-P 7 SDP-P 8 SDP-P Chimney Inside Diameter 6 inch 7-inch 8-inch 10-inch Dura-Chimney Allow at least a 2-inch clearance between 1400° F for one hour,and to 2100' F three times for ten Dura-Chimney or Dura-Plus and any combustible materials. minutes. Chimney Outside Diameter 10-inch 11-inch 12-inch 15-inch Where the chimney passes through floors,joists,or ceilings, Dura-Chimney and Dura-Plus are listed and produced under Support Box Framin Firestop Radiation Shields or Support Boxes may permit g 14''/inch 14%rinch 14'/rinch 18'/.-inch reduced clearances as established by these parts or spacers the Factory Inspection and Follow-Up Program of Under- QnsideDimensions) built on to these parts.Never fill any required clearance space writers Laboratories,Inc.(UL). Firestop Radiation Shield, with insulation or any other materials.Combustible materials 8 Insulation Shield Framing 14'/rinch 141/rinch 141/h-inch 181/.-inch include lumber,plywood,sheetrock,plaster and lath,furni- (Inside Dimensions) ture.curtains,electrical wiring,and building insulation of any Tools You May Need Materials You May Need Wall Thimble141/rinch 141/ inch 14'/rinch 18'/.inch kind,among other things. Hammer Non-hardening Water- Keep single wall stovepipe at least 18 inches away from Tape Measure proof Mastic Maximum Height per(DCR) 50 ft.DCR 50 ft.DCR 50 ft.DCR 50 ft.DCR combustible materials unless protective material that is Caulking Gun 8 Penny Nails Support (SDP) 35 ft.SDP 35 ft.SDP 35 ft.SDP — p Screwdriver 5/16 in.-3 in.Ion La acceptable to the authority having jurisdiction is used, Screws or the Saber or Keyhole Saw Scg g Clearance to Combustibles 2-inch 2-inch 2-inch 2-inch appliance to be installed is listed and the instructions specify Level Rooting Nails a different clearance. Plumb Bob 3/4 in.Galvanized Elec- PERMITS:Contact your local Building Code or Fire Officials Tin Snips trical Conduit(where regarding permits,restrictions,and installation inspection in Drill the chimney extends 4 _ your area. feet over the roof) SIMPSON DURA-CHIMNEY AND DURA-PLUS APPLICATIONS Safety Equipment DependDURA VENT Eye Protection roa coonle der � Use Dura-Chimney and Dura-Plus with fireplaces,furnaces, Eye Protection boilers.water heaters,stoves,ranges,or other residential-type Proper Gloves and Shoes Post Office Box 1510.Vacaville,CA95688.1510 appliances fueled by oil,gas,or wood.Do not use with forced INSTALLATION NOTES: Proper planning for your Dura- draft positive pressure appliances. Chimney or Dura-Plus installation will result in greater safety, •coPr^v+++—s.wa�D,..-v«.w PRINTED IN USA Dura-Chimney and Dura-Plus are designed to extend verti- efficiency,and convenience and save time and money. 12 119 cally with a maximum of(2)offsets of 30°(offset and return). Use only authorized Dura-Chimney (DCR) or Dura-Plus See Table 3 for maximum offset length. (SDP)listed chimney parts. You must use 100%Dura-Plus Dura-Chimney is listed for continuous flue gas temperatures listed parts to obtain a Dura-Plus listed chimney system.Do of 1000° F Dura-Chimney has been tested to 1000° F for not mix and match with other products or improvised 41/2hours,1400°Fforonehour,and to 1700°Fthreetimesfor solutions.Do not install damaged chimney parts. ten minutes. Practice good workmanship.Sloppy work could jeopardize Dura-Plus is listed for continuous flue gas temperatures of your chimney's safety.Keep electrical wiring and Insulation 1000°F.Dura-Plus has been tested to 1000°F for 41h hours, away from all chimneys and stovepipes. I