Loading...
HomeMy WebLinkAbout49477-Z �S�FFnr ao�y1 coG� Town of Southold 12/26/2023 P.O.Box 1179 W } 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44598 Date: 9/25/2023 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 2150 Park Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 123.-8-9 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/7/2023 pursuant to which Building Permit No. 49477 dated 7/14/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"window/door replacements and hot water heater/boiler to pre-existing single-family dwelling(rear waterside house)as applied for. The certificate is issued to JSK Park Ave LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49477 9/5/2023 PLUMBERS CERTIFICATION DATED ut ori d Signatur rJ:" TOWN OF SOUTHOLD o�SUFFoI�G w , BUILDING DEPARTMENT a TOWN CLERK'S OFFICE oy • � � SOUTHOLD, NY b dol � �a�ti;+• BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49477 Date: 7/14/2023 Permission is hereby granted to: JSK Park Ave LLC 159 W 24th St Apt 7B New York, NY 10011 To: legalize "as built" window/door replacements and hot water heater/boiler to pre-existing single-family dwelling (rear waterside house) as applied for. At premises located at: 2150 Park Ave, Mattituck SCTM #473889 Sec/Block/Lot# 123.-8-9 Pursuant to application dated 6/7/2023 and approved by the Building Inspector. Toexpireon _ 1/12/2025. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CO-ALTERATION TO DWELLING $50.00 Total: $450.00 Building Inspector ,OF SO!/j-ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 aQ James h(D—southoldtownny.gov Southold,NY 11971-0959 D�yCOUn�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: JSK Park Avenue LLC Address: 2150 Park Ave [rear house] city:Mattituck st: New York zip: 11952 Building Permit#: 4947,section: 123 Block: $ Lot: 9 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Homeowner Electrician: License No: SITE DETAILS Office Use Only Residential X Indoor Basement X Service Commerical Outdoor 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water X GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200 A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: Notes: AS BUILT Service and hot water heater/ boiler Inspector Signature: A& Date: September 5, 2023 2150 park ave rear house pf SOUryo a 150 Park Avg # # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm,��' I q 7 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: rReos- "o5e� f/ 16&A 64 I'bvvvev '2Lio7'�r le4 DATE d' Q2,� INSPECTOR k ,Y r r-• r 3 1 i T� l t" » MURRAY No�N�Z _ xoz.-~a <-n,7nn DANC:E:> A PELIORO "4O>7 JJFF73 �4 w o f 41 az ac, oe s Icc f r7 ri 1 or '06 I,01 �. ? w S4 f'91 20 �n i YO n 4 60iDL19 .� �I I F4 Am yy 6��'�rMV i� i in 41 F a �a�aFF L��N sl � �F 8 �!i 4A act. t y r 9 S!5 Ei3 t;, a F r � t I�E� �o�,�� 8 Master Electric : ii � � (.✓t�i� a C TR ww Closets no Sound ��t « pavbN Ovk i FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) i ------------------------------------ �C FOUNDATION (2ND) kA O ROUGH FRAMING& PLUMBING n 1 INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS _ L 1 ce'A . o 77-Z rn �6 - 5C H Z x� r H -- x d �a H Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) SARAH KIM, SOLE MEMBER OF 1JSK PARK AVENUE LLC residing at 159 WEST 24TH STREET, APT. 7B, (Print property owner's name) (Mailing Address) NEW YORK, NY 10011 do hereby authorize MARTIN D. FINNEGAN (Agent) to apply on my behalf to the Southold Building Department. C"- Owner's Signature) � (Date) JSK PARK AVENUE LLC BY: SARAH KIM, SOLE MEMBER (Print Owner's Name) Y fFOjr000. TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldto=.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only • t 1 � PERMIT NO. Building Inspector: "� JUN — 7 2023 Applications and forms'must be filled out in their entirety. Incomplete _ applications will not be accepted: Where the Applicant is,not the owner,'an, - Owner's Authorization form,(Page 2)shall be'completed.. ' Date:6/5/2023 OWNER(S)OF PROPERTY: Name:JSK PARK AVENUE LLC SCTM#1000-123.-8-9 Project Address:21.50 PARK AVENUE, MATTITUCK,,NY 11952 (FRONT COTTAGE) Phone#:917-520-9967 Email:SKIM_YTD97@HOTMAIL.COM;JSIREFMAN@SIREFMANVENTURES.COM MailingAddress: 150 HICKS„STREET,#4A, BROOKLYN,_NY 11201 CONTACT PERSON:, Name: MARTIN D. FINNEGAN (FINNEGAN LAW, P.,C.) -_- Mailing Address:PO BOX 1452, 13250_MAIN-ROAD, MATTITUCK, NY 11952 Phone#:6317315-6070 Email:MFINNEGAN@NORTHFORK.LAW DESIGN PROFESSIONAL INFORMATION:, Name:TBD Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:TBD- . .. - _-...-•. _ Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION El New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated cost of Project: 20therAS-BUILT WINDOWS&DOORS4 G $N/A Will the lot be-re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ANo 1 PROPERTY INFORMATION Existing use of property: RESIDENTIAL ,. Intended use of property:R.ESID_ENTIA _- ..._.__. Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to 14-40 this property? ❑Yes ®No IF YES, PROVIDE A COPY. A Check Box After Reading: The owner/contractor/design professionalU responsible for all drainage and storm water issues as provided by Chapter 230 of.the Town Code. APPLICATION IS HEREBY MADE to the,Building Department for the issuance of a Building Permit pursuant to the Building Zone. Ordinance of the Town of Southold,Suffolk,County,New York and'other applicable Laws,Ordinances or Regulations,foe the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,'building code,. housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary"inspections.False statements made"herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State.Penal Law., Application Submitted By(pri • MARTIN D. FI N N EGAN BAuthorized Agent ❑Owner Signature of Applicant: Date: 6/5/2023 STATE OF NEW YORK) SS: COUNTY OF SUFFOLK ) MARTIN D. FINN EGAN being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the AGENT (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day ofJUNE 2023 , Notary Public SCHWEITZER ANNALISE NOTARY PUBLIC-STATE OF NEW YORKCHWEITZER ANN E NO.01SCsa09457 PROPERTY OWNER AUTHORIZATION NOTAR BLIC-STAT NEW YORK QUALIFIED IN SUFFOLK COUNTY �� MY COMMISSION EXPIRES SEP 28,20 24 (Where the applicant is not the owner) CIF,!IFi :: �r:,,.;,:,;)'NTY LMYCOMMIS E7� =S SEP 28,20 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 %SgfF01��OGy BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD C* Town Hall Annex - 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 yjj O� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerria'D-_southoldtownny.aov - sea nd(a)-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: JSK PARK AVENUE LLC Address: 2150 PARK AVENUE, MATTITUCK, NY 11952 (REAR HOUSE) Cross Street: MARRATOOKA ROAD Phone No.: 917-520-9967-JOSHUA SIREFMAN Bldg.Permit#: 4 9 � 71 email: MFINNEGAN@NORTHFORK.LAW Tax Map District: 1000 Section: 123.00 Block: 08.00 Lot: 009.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): UPGRADED ELECTRICAL SERVICE AND PANEL WITH ROMEX WIRING. Rz&r �-Nw r Square Footage: Circle All That Apply: Is job ready for inspection?: 17 YES ❑ NO ❑Rough In � Final Do you need a Temp Certificate?: ❑ YES ❑✓ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 0 1 n2 H Frame Pole Work done on Service? DY N Additional Information: PAYMENT DUE WITH APPLICATION ��OS�FFQ���pG BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box 1179 CA '* Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov - sea nd(-Dsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 6/7/2023 Company Name: HOMEOWNER Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: JSK PARK AVENUE LLC Address: 2150 PARK AVENUE, MATTITUCK, NY 11952 (REAR HOUSE) Cross Street: MARRATOOKA ROAD Phone No.: 917-520-9967 -JOSHUA SIREFMAN Bldg.Permit#: cf f y'v email: MFINNEGAN@NORTHFORK.LAW Tax Map District: 1000 Section: 123.00 Block: 08.00 Lot: 009.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): UPGRADED ELECTRICAL SERVICE AND PANEL WITH ROMEX WIRING. Square Footage: 1 7105 Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: ❑ YES ❑✓ NO Issued On Temp Information: (All information required) Service Size❑1 PhF-]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 FJ2 H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION � 0 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o = Town Hall Annex - 54375 Main Road - PO Box 1179 ^+ Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cDsoutholdtownny.gov — seand(c_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 6/7/2023 Company Name: HOMEOWNER Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: JSK PARK AVENUE LLC Address: 2150 PARK AVENUE, MATTITUCK, NY 11952 (REAR HOUSE) Cross Street: MARRATOOKA ROAD Phone No.: 917-520-9967 -JOSHUA SIREFMAN Bldg.Permit #: Z#iW, 4 q c) email: MFINNEGAN@NORTHFORK.LAW Tax Map District: 1000 Section: 123.00 Block: 08.00 Lot: 009.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): UPGRADED ELECTRICAL SERVICE AND PANEL WITH ROMEX WIRING. �2, L ! I n ' �� -41A)A �v k 4/��i I-el Square Footage: 1 GSD Circle All That Apply: , Is job ready for inspection?: YES ❑ NO F—]Rough In ❑✓ Final Do you need a Temp Certificate?: ❑ YES ❑✓ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 000 hmP ilo �Vkce_ PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments S.C.T.M.# DISTRICT 1000 SECTION 123 BLOCK 8 LOT 9 & 10 t° U.P.", t, VV W.V. e' D.P.44 b 0' \N 'N 10 OAK ptr9� 0° C15T501 \`.(,\oOronK \ 9TMf'C\S ocus d \ 20�N Of pP £ 09 4 +9 10'L \ 6 \yy foo JQ +91Q�°6. \9e 10'MAPL 1AA \ 6 n 12OAK f � -\ 105 2 v y ( '? STY FRAME 9g \ DWELLING FFL=21.7 \ Z\ 1 #2200. 99 •yNA� \ \\ D 1\'OAK .1 STY +a 'FRAME \ T,L\ CONC. 0 _DWELLING \ �; PATIO i7 .P. EXISTING LOT COVERAGE 0 FFL216' AREA LANDWARD OF CREST OF BANK:27869 S.F.or 0.64 ACRES #1156' \ \9L 7 +99 P`1 o DWELLING(NORSH): S.F. - TO a SHED:76 S.F. I £ \$ DWELLING(SOUTH).1684 S.F. I TOTAL:2841 S.F.or 10.2% qt CONC o PATIO \9y / ASPHALT c^ DRIVEWAY+°+ / 4 g$ / \I4'OAK ,a ,C. ( i6 EXISTING LOT COVERAGEs \ 99 \ dzz OAK \ AREA LANDWARD OF CREST OF BANK:27495 S.F.or0.63 ACRES �+^,P \� 9�4" `B s' aK I DWELLING(NORTH):1081 S.F. 0"OA J.Du1 c') 1 \ SHED:76 S.F. DWELLING(SOUTH}1664 S.F. \ Q +by 1 TOTAL 2841 S.F.or 10.3% I.5,W 16 oAK I �m 6'©6'OAK \ 20' ry\f•�.. fi a� / \t9 10"OAK �a61OAK \to S.C.T.M.#1000-123-8-11.3 1'4'W 7 LAND N/F OF \91`q� IQ j 10 0A1tP' CNC PARK AVENUE LLC 'r \0 + 6'ON( 20'OAK Q 10 OAN @d I 15 6'OAK j 14'OAK 6 c 6'OAK N 1Q 11 10'OAK 0•OAK DWELLINGS 6 OAK u? moo,.,6'0. y W/PUBLIC WATER 1.7` e 1© +�` J5 `i•QAK \ 150' e'oAK l Q SHED 01 \ 6'M12.OAK 6. Iv OAK \lJ IAL d NZ SNEO \e° 7 d 2.7' +6 14"O K 222""OAK S.C.T.M.#1000-123-8-8.3 %6. U.P / LAND N F OF 9 � TIMOTHY MURRAYASPHALT DWELLINGS \ DRIVEWAY W/PUBLIC WATER 2.9'E e 150' IT`oAK a o' R 'y 14'OAK MON. 9 \19 \t. 10' I© 14.OAK \19 1©AK\ `19 16"OAK 10 0 N B'OAK e \t9 Q 12'•OAK F T �A 6 6' K 7/ SHOWER S\1B O 10'Q4K \4 �N 1A� rOf3 FENCE �2?; ELEV. 18.2 SM BROWN SILTY SAND 5.0' 04 — PALE BROWN FINE gPy SP SAND /fQ `6a 22A' v' .tI Y R 17.3' oo �C.P) WATER IN 4p• PALE 0P+00 v� 1� SP BROWN \11 PNt * ZONE X � _ --� 3.2'E 1` SAND 29'381 / \y9yy APRIL 15. 2022 �+C�. I C P.) McDONALD GEOSCIENCE E 0f 8°1H i / NV7 DONONBN S1 f 0 B OGP O `b+ � ��/ �� FLOOD 20NC Is -14' PV" i/•/ 00A�N MGH q2 W s FEMA MAP#36103CO482H NAVD88 / � z AREA:59,791.66 SQ.FT. or 1.37 ACRES ELEVATION DATUM.- LAZONE VE(EL 8) NW UNAUTHORIZED AL TERA RON OR ADDI TON TO RNS SURVEY 15 A VIOLA KON OF SECTION 7209 OF THE NEW YORK STATE EDUCATION W. COPIES OF THIS SURVEY i'/ S S0}8 p1,ON0 O MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY GUARANTEES INDICATED HEREON SHALL RUN / nf.SINES ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE RILE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION. GUARANTEES ARE NOT TRANSFERABLE. MHW EQUALS TIDAL WEIINID BOUNDARY THE OFFSETS OR WN DIMENSIONS SHOHEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE AS DEHRNINED BY A 1 NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE£RECKON OF FENCES,ADOIRONAL 57RUCTURES OR AND OTHER IMPROVEMENTS EASEMENTS EN-CONSULTANTS 11-09-22 a l^ AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF:DESCRIBED PROPERTY OF NEW CERTIFIED TO: JSK PARK AVE, LLC; 0� MAP OF. A.P ASH M. wO/•o'p S 1 FILED: SITUATED AT:MATTITUCK z TOWN OF:SOUTHOLD o a� KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK ys 050857 �Q- Professional Land Surveying and Design F THE WATER SUPPLY, WELLS, DRYW£LLS AND CESSPOOL 5 P.O. Box 153 Aquebogue, New York 11931 LOCA77ONS SHOWN ARE FROM FIELD OBSERVAKONS FILE#222-113 SCALE:1"-30' DATE:AUG. 30, 2022 N.Y.S. L/SC. NO, 050882 PHONE(831)298-1588 FAX(631)298-1588 AND OR DATA OBTAINED FROM OTHERS. :Andersen®- wI N D,O W:S,--D__0 6-RI 'I H"inged .-Patio. Doors - Insw.i.ng Contents Hinged Patio Doors- Inswing Basic Unit Details .........................................................26-2 r Options/Accessories Accessibility Option................................................26-5 . 1 b Andersen Grilles....................................................26-6 Extension Jambs.................................................... 26 w -- Anchoring Methods.......................................................26-8 ;. Joining Details 26-9 Su -10 Product lications 26-10 gg pp • 20/10 year limited warranty,fully transferable, non-prorated. COMPLY WITH ALL CODES OF • Choose Low-E tempered or Low-E Sun tempered NEW YORK STATE & TOWN CODES glass. Dual-pane tempered insulating glass is also AS REQUIRED AND CONDITIONS OF available. n • Smooth,easy operation. SC OLD T�WNG BOARD • Choose White,Sandtone orTerratone° color exteriors. hi'TRUSTEES • White interiors can be painted to match home's N•Y.G.BEe — decor. OCCUP.,ANCY OR AP R VED AS NOTED [AFIS UNLAWFUL DATE:, 13 P.# 7 WITHQUT CE°RTIFICAT FEE: BY. CF OCCUPANCY NOTIFY.-BUILDING DEPARTMENT AT 765402 SAM TO :4 PM FOR THE FOLLOWING.INSPECTIONS: 1. FOUNDATION:- TWO REQUIRED FOR POURED CONCRETE" .2. ROUGH -"FRAMING & PLUMBING 3. INSULATION 4. FINAL: ' CONSTRUCTION MUST BE COMPLETE FOR C.O. ELECTRICAL ALL CONSTRUCTION SHALL MEET THE INSPECTION REQUIRED REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. eEv. iz/os A R C H I T E C T U R A L D E T A I L F I L E 26-1 M .Andersen ® . WI=NDOWS • DO.O.RS ; Hinged Patio Doors - .InSWing_' Basic Unit Details - Single and Two Panel Basic Unit Scale 3" = 1'-0" (1:4) 1-5/16"(33) 4-9/16"(116) 1-5/16"(33) 4-9/16"(116) 7T] 3/4"(19) _ 1 1 5-5/8"+(143+) I 5-5/8"+(143+) depending on depending on hinge adjustment hinge adjustment L L. Head Head m oa m on m m O C C N C C Ofl D. o E E E c - Andersen® Andersen' optional optional gliding 10-3/8"+(264+) hinged 10-3/8"+(264+) insect screen depending on insect screen depending on 1 hinge adjustment hinge adjustment 8 1/4"(6) 1/4"(6) A:A _1-1/4 (318) �� � 1-1/4"(318) SIIIIISill 6"(152) 6"(152) Vertical Section - with Gliding Insect Screen Vertical Section - with Hinged Insect Screen Two Panel - Active/Stationary or Stationary/Active Single Panel - Active Two Panel - Active/Stationary or Stationary/Active 26-2 A R C H I T E C T U R A L D E T A I L F I L E REV. 12/06 ' :. l .Andersen i WJ'nDOW s D.00Rs Hinged: P`ati.o D.o-_o-.rs- Inswing: I Basic Unit Details - Single and Two Panel Basic Unit Scale 3" = V-0" (1:4) Metro,Collection Tribeca°handle hardware Dual-pane insulating tempered glass 5-5/8"(143) 5-5/8"(143) 3/4"(19) ...="_ —�\ 3/4"(19) -- " Optional Andersen') A hinged insect screen Jamb Jamb 1-1/4" Clear Opening Width 1-1/4" (318) T (318) Unit Dimension Width 3/8"(10) 3/8"(10) Minimum Rough Opening Width Horizontal Section - with Hinged Insect Screen Single Panel Active Stationary Panel Active Panel 5-5/8"(143) 5-1/8"(130) 5-1/8"(130) 5-5/8"(143) 3/4"(19) 3/4"(19) I I I - Astragal Jamb Jamb 50=2'5-5/8"(752) 50=2'5-5/8"(752) 54-2'7-5/8"(803) 54-2'7-5/8"(803) 60=2'11-5/8"(905) 60=2'11-5/8"(905) Unit Dimension Width 3/8"(10) 3/8"(10) Minimum Rough Opening Width Horizontal Section - with Gliding Insect Screen Two Panel - Stationary/Active (shown) or Active/Stationary REV. 12/O6 ARCH ITECTU RAL D E T A I L F I L E 26-3 n seder. �n .' A :r I N'1116-WS D O 0 R S ®L H'i h�g e.,d: -P a-i o' D'o o-r s -=--:I n''s-vi n:9~Y° Basic Unit Details - Single and Two Panel Basic Unit Scale 3" = 1'-0" (1:4) Door at 901 clear opening position i .rte. Door at full clear ' I. opening position El I Jamb Astragal lamb Clear Opening Width at 90° Clear Opening Width Full Open Position 50=2'5-5/8"(752) 50—2'5-5/8"(752) 54-2'7-5/8"(803) 54—2'7-5/8"(803) 60=2'11-5/8"(905) 60=2'11-5/8"(905) Unit Dimension Width Horizontal Section Stationary / Active 26-4 A R C H I T E C T U R A L D E T A I L F I L E REV. 12/06 Andersen ® : WIDOWS.,-•DOORS NHinge`d :Pa`tio Doors -,`.InsXin Basic Unit Details - Stationary Panel Basic Unit Scale 3" = 1'-0" (1:4) 1-5/16"(33) 4-9/16"(116) 3/4"(19) 5-5/8"(143) 5-5/8"(143) 5-5/8"(143) m 3/4"(19) 3/4"(19) � c �n tin x o. PW— .0 Head EIL9 o � E o Jamb lamb 10-3/8"(264) 1-1/4" 1-1/4" (318) Unit Dimension Width (318) Minimum Rough Opening Width 1/4"(6) Horizontal Section Stationary Panel — t 1-11318) SIII 6"(152) Vertical Section Stationary Panel Accessibility Option Scale 3" = V-0" (1:4) Accessible Door A special"accessible door'option is available that offers a 32"clear opening Low threshold sill width at 901 and a 1/2"high threshold. Meets door width and threshold height requirements of ICC/ANSI A-117.1-2003 and ADAAG guidelines.Contact your Andersen supplier for availability. 1/2"(13) REV. 12/06 A R C H I T E C T U R A L D E T A I L F I L E 26-5 wndersen ®` Hing ;Patio Dors I s`win:g Standard Grille Options / Accessories Contact an Andersen Representative for project specific grille options. 200 Series Grille Options Removable Interior Andersen®FineligWm Grilles Grilles-Between-the-Glass i Grille Profiles scale = Full Removable Interior Wood Grille Profiles(chamfer profile). 7/16" 7/16" 7/16" Z��L L L 3/4" 7/8 I 1-1/8" r i Andersen°Finelighem Grilles-Between-the-Glass 3/8" 1/2" 3/4" 1" Window Profile Patio Door Profile 26-6 A R C H I T E C T U R A L D E T A I L F I L E REV.12/06 i. ®. . Andersen ® �g � . g wiluoows • uoolts . Hin ed Pat"io` Doors Inswln Options / Accessories Prefinished White Interior Extension Jambs Scale 3" = 1'-0" (1:4) 11/16°(17) T _ - ------------------- u, --- N V LL 7-1/8"(181) 6-9/16"(167) 5-1/4"(133) Extension jamb Extension jamb Extension jamb 4-9/16"(116) Interior extension jambs have a low-maintenance white finish 1-5/16"(33) and are available for 5-1/4"(133),6-9/16"(167),and 7-1/8"(181)wall thickness.Other wall dimensions can be accommodated with extension jamb modification.Extension Unit Dimension Width jambs are pre-drilled for easy application. Rough Opening Width Width Horizontal Section Interior Extension Jambs:The use of Full panel interior extension operation O jambs will restrict Installed flush�r Restricted panel i panel operation on to interior wall operation i jamb hinged doors. A Jamb hinged patio Optional serP lambss jamb doors must be installed flush to the interior to achieve full Exterior trim and 1-3/4"(44) panel operation. flashing by others—r Jamb hinged patio door In 2 x 6 wall Jamb hinged patio door In 2 x 6 without extension Jambs wall with extension Jambs R E V. 1 2/0 6 A R C H I T E C T U R A L D E T A I L F I L E 26-7 ,Andersen :wiN,uo:ws • o-oo'Rs.. Hln.ge'd 'Patio Door's In'swing:" � Anchoring Methods scale 3" = 1r-0° (1:4) Wood Screw Fastener/Flange in Standard Position Wood Screw Fastener/Flange in Reversed Position Patio door unit is secured in opening using wood screw fasteners through the jamb Patio door unit is secured in opening using wood screw fasteners through the (the flange itself cannot support the door). jamb(the flange itself cannot support the door). Wood screw Wood screw fastener "- fastener •wf ; 0 io io rn ;ro. M771 n 1, x: ..sem..y. `:'tt•. Exterior sheathing Flange Flange in ` ... reverse position Threaded Masonry Fastener / Expansion Sleeve Make sure that the unit frame parts do not become bowed when using anchoring methods.Unit will not Patio door unit is secured in opening by pre-drilling through side jamb into masonry. operate properly if frame parts are stressed. Threaded masonry fastener n¢k, 0 �1+ Flange removed 26-8 A R C H I T E C T U R A L D E T A I L F I L E REV. 12/06 y 41 i Andersen®: v .<< W NVows • 5ooRs ®. Hln'ged„ Patio Doors Inswing ;, w,..u. Joining Details Andersen® Joining Materials _ Scale 3” = 1'-0" (1:4) Joining Compatibility Many Andersen®units are designed to be joined with other Active Panel Stationary Panel Andersen units in a variety of non-reinforced and reinforced 3/4"(19) 2 (51) 3/4"(19) combinations.Other combination types and joining methods can be viewed in the Andersen Product Guide for Professionals, Interiortrim and in Andersen Window Studio°software,and by visiting extension jambs by others andersenwindows.com.Combination designs should always be Structure by others checked for design pressure performance reauirement§to make sure the appropriate joining method is specified. I I ' I i I I I I w� I Optional Andersen® 2 (51) \Optional Andersen®2"support w support mullion mullion trim strip set in continuous wood filler bead of sealant each side 211 Support Mullion Frenchwood®Patio Door Transom on x 0 Optional Active Panel Stationary Panel Andersen® 3/4"(19) reinforced LVL o strip 3/4"(19) 3/4'(19) joining � Optional Andersen® 1"(25) wood casing :.t .. ;".. 3/4..(19) 3/4"(19) 3/4"(19) Trim strip set in continuous bead of sealant each side v R" O Trim strip set in continuous Optional Andersen® bead of sealant each side 3/4"(19) reinforced LVL joining strip Inswing Patio Door Andersen® LVL Reinforced Mullion Andersen® LVL Reinforced Transom REV. 12/06 A R C H I T E C T U R A L D E T A I L F I L E 26-9 - - - — °Andersen ® W.INoo.w.s_• DV0WS H_i.n' d-v Pati. ' Doors Inswln. ' Suggested Product Applications Wall Types Scale 1-1/2" = 11-0" (1:8) Remove flange at head and Flange at he jambs and jambs V-7777Y Optional Andersen® insect screen PW Head Head 3/8" 3/8 (10) (10) — t m m m o an no E E o c - E ms E ..y Jamb arse � Jamb "�T Optional Andersen® insect screen CQ o o BUM- Sill Sill Vertical Section Vertical Section Wood Siding/ 2 x 4 Wood Stud Framing Brick Veneer/ 2 x 6 Metal Stud Framing Minimum Rough Opening Rough opening dimensions shown are the minimum dimensions recommended for proper installation.These dimensions may need to be increased to allow for use of building wraps, flashing,sill or pan flashing,brackets,fasteners or other items which could decrease these dimensions.Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer. Importance of Proper Installation Proper installation and maintenance of Andersen'products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12,Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. Construction by Others Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units. NOTE:Where E.I.F.S.wall finish is adjacent to units,contact E.I.F.S.manufacturer for installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealantjoint around the perimeter of the unit. NOTE:Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.Flange may be removed where construction sequence/detailing requires no flange. 26-10 A R C H I T E C T U R A L D E T A I L F I L E R E V. 1 2/0 6 ---------- 7-7 4 6d�, Pat�i D,:'o o r-s-'� 1'n�svJn-9.em"An ers,WINA OVS � D'0ORs ®@uHihg Suggested Product Applications Wall Types 6 Flange at head and jambs Exterior trim by others Optional] Andersen insect screen Membrane flashing over Head Head flange(by others) 3/8" d 3/8" (10) 1� (10) 1-2 X15 :2 Z 45 C) yA .2 E rr E 1—h am Optional r, Andersen insect screen 0 Sill Sill Vertical Section Vertical Section E.I.F.S. Concrete Masonry Unit (CMU) Brick/ Concrete Masonry Unit (CMU) Minimum Rough Opening Rough opening dimensions shown are the minimum dimensions recommended for proper installation.These dimensions may need to be increased to allow for use of building wraps, flashing,sill or pan flashing,brackets,fasteners or other items which could decrease these dimensions.Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer. Importance of Proper Installation Proper installation and maintenance of Andersen®products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12,Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. Construction by Others Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units. NOTE:Where E.I.F.S.wall finish is adjacent to units,contact E.I.F.S.manufacturer for installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width ofsealantioint around the perimeter of the unit. NOTE:Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.Flange may be removed where construction sequence/detailing requires no flange. R E V. 12/0 6 ARCH ITE CTU RAL D ETAI L FILE 26-11 'a ti a Doors- ---. Inswing, ,- Andersen®- W'IN-0O'W.S k-09—ed P Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) Exterior trim by others Exterior trim Existing by others frame wall 1-3/16"(30) Flange at head Flange at head and jambs and jambsP Head H,ad 3/8" Exterior trim 3/1'; (10) by others (10 :Lw Z E 0 2 V5 E E E 15 Jamb �t Jamb Optional Optional Andersen® Andersen® insect screen fk insect screen Sill Sill Vertical Section Vertical Section Stucco Concrete Masonry Unit (CMU) Inset Door Existing Wall Minimum Rough Opening Rough opening dimensions shown are the minimum dimensions recommended for proper installation.These dimensions may need to be increased to allow for use of building wraps, flashing,sill or pan flashing,brackets,fasteners or other items which could decrease these dimensions.Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer. Importance of Proper Installation Proper installation and maintenance ofAndersen*products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12,Bayport,IVIN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. Construction by Others Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units. NOTE:Where E.LES.wall finish is adjacent to units,contact E.U.S.manufacturer for installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width ofsealantlont around the perimeter of the unit. NOTE:Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.Flange may be removed where construction sequence/detailing requires no flange. 26-12 A R C H I T E C T U R A L D E T- A I L F I L E R E V.1 2/0 6 S er -n d se I NAMT i I.t=W a s'h ;.D o`u_:b`;Ge=.`li:i7n 'IV W i`n:d:o.wa $;...D�:OOR:S;.:...,, . ...... ..-� ,._,..:.- :.:...... - �.g Contents Tilt-Wash Double-Hung Windows - - Basic Unit Details- {' Tilt-Wash Double-Hung Windows for 4-1/2"Wall...............................................19-2 Basic Unit Details Picture,Transom and CircleTopTm Windows with Extension Jambs......................19-3 Basic Unit Details Tilt-Wash Double-Hung Drywall Return. ba ........................................19-4 Basic Unit Details t> j Picture,Transom and Circle TopTm Windows with Drywall Return.........................19 5 Options/Accessories ,;. ..:.. Andersen'Grilles.......................................................................................19-6 Extension Jambs forTilt-Wash Double-Hung Windows.....................19-7 =` Stool Applications..........................................................................19-7 20/10 year limited warranty,fully transferable, Extension Jambs for Picture,Transom and Circle TopTm Windows......19-8 non-prorated Trim Options and Applications Low-E or dual pane insulating glass Plinth Blocks for CircleTopr'Windows..............................................19-9 White or sandtone vinyl clad low-maintenance Interior Casing for Circle TopT`"Windows.........................................19-10 exteriors Joining Details for 4-1/2"Wall ........................................................................19-11 • Narrow profiles for larger glass area An in-sash balancer to minimize the view of Joining Details with Drywall Return..................................................................19-12 • thejamb liner Anchoring Methods.........................................................................................19-13 Clear pine or optional prefinished white Suggested Product Applications......................................................................19-14 interior Innovative sizing format to simplify ordering and installation REV.03/05 A R C H I T E C T U R A L D E T A I L F I L E 19-1 o:ubF­`z'.H �ng, erre t,,.n -:b` fe.- ;u S-I!, .00R h Basic Unit Details Tilt-Wash Double-Hung Windows for 4-1/2"Wall Scale 3" = 1'-0" (1:4) 4-1/2" (114) 1-5/16" 2-5/8" 1-7/8" (33) (67) (48) 1/4" Optional (6) insect screen 11/16"(17) 3 ------- 1/2"(13) (76) 1-7/8"(47) Head 2-1/8"(54) 13/16" o .E (46) C) Lower sash in full open position :SP M Check Rail O 1-7/8"(47) T (76) 1/2"(13) 11/16"(17) 1/f 4" (6) sill Vertical Section 1/2' 1-13/16' 1/2" 1-13/16' 11/16" (13) (46) 11/16' (13 (46) (17) Lower (17) Lower sash sash 4-1/2' 4-1/2" (114) (114) 3-3/16" Upper 3-3/16" Upper (81) sash (81) ----- sash 1-5/16" (3 3) Z Jamb 3" 3" Jamb Jamb 3" 3.1 Jamb (76) Glass Width (76) (76) (76) Glass Width I I J� 1 Unit Dimension Width —1/4" 1/4" Unit Dimension Width 1/4" (6) Rough Opening Width (6) Rough Opening Width (6) Horizontal Section Horizontal Section Through Upper Sash Through Lower Sash 19-2 A R C H I T E C T U R A L D E T A I L F I L E R E V.0 3/0 5 Aner: n d se =W ' D`o'u `�H'ii''n� =W�i,n�d o; s �`i:'I,t: a�sfi�'. 'T o was �" g.:: Basic Unit Details Picture, Transom and Circle Topes" Windows with Extension Jambs Scale 3" = 1'-0" (1:4) 4-1/2"(114) 4-1/2 (114) 1-5/16" 3.3/16" 1-5/16" 1-5/16" 3-3/16" 1-5/16" (33) (81) (33) (33) (81) (33) i Optional Andersen') 1/4" extension jamb 1j4" Optional Andersen° (6) (6) extension jamb 11/16"(17) 11/16"(17) 3/8°(10) 1 3/8"(10) 3" 3" (76) 1-15/16"(49) (76) 1-7/8"(47) o 25 bL m W tD = LCII CO Lw OO � - y = Head = Head n a y n c l2 o E o E p C.0 m o c5 m .0 =O 1-15/16"(49) 3„ 3" 1-7/8'(47) (76) (76) 3/8'(10) 3/8"(10) 11/16"(17) ��� �! 11/16"(17) 1/4" 1/4" Sill (6) Sill (6) Vertical Section Vertical Section Picture or Transom Circle Top' Unit 3/8" 1-15/16" Optional Andersen® 3/8" 1-7/8" Optional Andersen® 1 (10) (49) extension jamb 11/16" (10) (47) extension jamb (17) (17) (17) 4-1/2" 4-1/2" (114) 3-3/16" (114) 3-3/16- (81) (81) 1-5/16" 1-5/16" (33) (33) 3„ 3„ 3: 3: Jamb (76) Glass Width (76) Jamb Jamb (76) Glass Width (76) Jamb 1/4" Unit Dimension Width 1/4„ 1/41. Unit Dimension Width 1/4" (6) (6) (6) (6) Rough Opening Width Rough Opening Width Horizontal Section Horizontal Section Picture,Transom Circle Top m Unit REV.03/05 ARCH I T E C T LI RAL D E T A I L F I L E 19-3 ®i de e s An a in:.Ws °: o - D O:W S.: D,O.O'R,. .. .: ...:. g: Basic Unit Details _ Tilt-Wash Double-Hung Windows with Drywall Return Scale 3" = 1'-0" (1:4) 1-5/16" 3-1/16" (33) (78) Drywall return 1/4" Optional (6) insect screen 1-1/16"(27) 3" (76) 1-7/8"(47) en = Head m co � t tp UD x x 2-1/8" 1-13/16" m (54) a (46) o E m 0 Lower sash in o full open position m E Check Rail x m a 0 1-7/8"(47) 3" (76) 1-1/16"(27) 1/4" (6) Sill Vertical Section 1-1/16" 1-7/8" 1-1/16" 1-7/8" (27) (47) (27) (47) Lower Drywall Lower Drywall sash return sash return 3-1/16" Upper 3-1/16" Upper (78) sash (78) ___ _ sash 141- F (33) Q` (33) Jamb T. 3" Jamb Jamb 3" 3" Jamb (76) Glass Width (76) (76) Glass Width (76) Unit Dimension Width 1/4„ 1/4 Unit Dimension Width 1/4" (6) Rough Opening Width (6) (6) Rough Opening Width (6) Horizontal Section Horizontal Section Through Upper Sash Through Lower Sash 19-4 A R C H I T E C T U R A L D E T A I L F I L E REV.03/05 Andersen - `wµ:"id o'w's` -'s -®:/ TI t .WaI'sti D."o`u 6`i'e ..H un `c Basic Unit Details Picture,Transom and Circle TopT°° Windows with Drywall Return Scale 3" = 1'-0" (1:4) 1-5/16" 3-1/16" 1-5/16" 3-1/16" (33) (78) (33) (78) 1/4" Drywall return 1/4" Drywall return (6) (6) 1-1/16"(27) 1-1/16"(27) 3" 3" (76) 1-7/8"(47) (76) 1-7/8"(47) Dp UO UO Y]D m 0 N = Head — F+ = Head n O E o E o 3 1-7/8"(47) 3" 1-7/8"(47) (76) L—] (76) 1-1/16"(27) 1-1/16"(27) 1/4" 1/4" Sill (6) Sill (6) Vertical Section Vertical Section Picture or Transom Circle TopTm Unit 1-1/16" 1-7/8" 1-1/16" 1-7/8" (27) (47) (27) (47) Drywall return Drywall return 3-1/16" 3-1/16" (78) (78) 1-5/16" 1-5/16" (33) (33) 3„ Y 3" 3, Jamb (76) Glass Width (76) Jamb Jamb (76) Glass Width (76) Jamb 1/4" Unit Dimension Width1/4" 1/4" Unit Dimension Width 1/4" (6) (6) (6) (6) Rough Opening Width Rough Opening Width Horizontal Section Horizontal Section Picture,Transom Circle Topes" Unit REV.03/05 A R C H I T E C T U R A L D E T A I L F I L E 19-5 Aner :n d se sh Double Hu'n- "Windows -`Y 0 o wa •:o Ra : T i-i.t...W a g , Standard Grille Options / Accessories Contact an Andersen Representative for project specific grille options. 200 Series Grille Options Removable Interior Andersen'Finelight' Grilles-Between-the-Glass I Grille Profiles scale = Full Removable Interior Wood Grille Profiles(chamfer profile). 7/16- 7/16" 7/16" 3/4" 7/8" I 1-1/8" Andersen'Finelight'Grilles-Between-the-Glass 1/2" 3/4„ V. Window Profile Patio Door Profile 19-6 ARCH ITECTU RAL D E T A I L F I L E REV.03/05 ndersen ` iv, �' '!t...W as h H.un ;Wi,'hd Q w s.';.. .:.W'I WiS:._D:O O R`S..®'' ,.,...-.•;...:.-.:, g�..:... . Options / Accessories — -------------------------------------------- -------- Extension Jambs for Tilt-Wash Double-Hung Windows Scale 3" = 1'-0" (1:4) 9/16- (14) /16"(14) r- i v I _ Cv 4-1/2° N- ------I---- o 4a.. Wall - o0 6-9/16" 5-1/4" Wall Wall Wall LL M 00 ch in v _ � C a CP Jamb Horizontal Section Extension jambs available for 5-1/4"(133),6-9/16"(167)or 7-1/8"(181)wall thickness. Other wall dimensions can be accommodated with extension jamb modification. Options / Accessories Stool Applications (by others) Scale 3" = 1'-0" (1:4) Stool (by others) Stool (by others) 0 0 Sill Sill Vertical Section Vertical Section Tilt-Wash Double-Hung Picture,Transom or Circle Top'' Units REV.03/05 A R C H I T E C T U R A L D E T A I L F I L E 19-7 der se ;n �An o ws o�ws'.�.u' Rs.r®•' T11t -W'`ash"�:Dou:b�le`•°H"u`ng Wind _ 0.;0 - Options / Accessories Extension Jambs for Picture, Transom and Circle Topes" Windows Scale 3" = 1'-0" (1:4) 7-1/8"(181) 7-1/8"(181) 6-9/16"(167) 6-9/16"(167) 5-1/4"(133) 5-1/4"(133) 4-1/2"(114) 4-1/2"(114) i l i i I I Al i I I i i I i I I i i I 1 I I II I I I I II I u I I I r Optional u r Andersen® r n U l arch casing Face: J 1 Face: 1-5/16"(3 ) 4-1/2"Wall 1-5/16"(3 ) 4-1/2"Wall 7.7 EF#La4m ? - Face: I Face: 2"(51) 5-1/4"Wall 2"(51) 5-1/4"Wall 1/8„(3) 1/8"(3) Face: Face: i 3-5/16"(84) 6-9/16"Wall 3-5/16"(84) 6-9/16"Wall Face: Face: 3-7/8"(98) 7-1/8"Wall 3-7/8"(98) 7-1/8"Wall Picture/Transom-Head Circle Top-Head li I u 1 J I i 1 i n l I I I 1 1 i 1 i I I r 1 r n 1 r I r q I I I i I I 1 Picture/Transom-Sill Circle Top-Sill Vertical Section Vertical Section Picture/Transom Units Circle To pm Units Extension jambs available for 4-1/2"(116),5-1/4"(133),6-9/16"(167)or 7-1/8"(181)wall thickness. Other wall dimensions can be accommodated with extension jamb modification. 19-8 A R C H I T E C T U R A L D E T A I L F I L E REV.03/05 AnGIese n C. D oit-��fi' e. H°u n W i.n d ' I Trim Options and Applications_ Plinth Blocks for Circle.Top'' Windows Scale: Half Available in maple, oak and prefinished white. Optional Andersen interior arch casing (Colonial or Ranch styles) 2-1/4"Colonial Style Also available in prefinished white Optional Andersen' r with prefinished transom casing y`f` plinth block applied. Optional Andersen plinth blocks Intedortrim by others 3-7/8"(98mm) 2-7/8"(73mm) 2-7/8"(73 M) 3-7/8"(98mm) �7�/ (22mm) 7/8'(22mm) For use with 2-1/4"or 2-1/2"(57mm or 64mm)casing. For use with 3-1/2"(89mm)casing. REV.03/05 ARCH ITECTURA L D E T A I L F I L E 19-9 de n r� e An s s." I't��"'`W �u'bfe-Hl'u n in Trim Options and Applications Interior Casing for Circle Topes" Windows Scale: Full Available for all curved portions of windows. l X` ' r 3t'k.a3 �Is Ranch Style-WM 315 2-1/2"x 11/16"(64mm x 17mm) Available in maple only. Ranch Style-WM 324 2-1/4"x 11/16"(57mm x 17mm) Available in maple or oak. '^r 3 "x. Colonial Style-WM 351 2-1/2"x 11/16"(64mm x 17mm) Available in maple only. a, 5/32"(4mm)typical 77 Colonial Style-WM 366 , ' ", - 2-1/4"x11/16"(57mmx17mm) r a f^. Available in maple or oak. .! Also available prefinished whiten is with prefinished plinth block attached. Colonial Style-WM 444 Optional Andersen® 3-1/2"x 11/16"(89mm x 17mm) extension jamb Available in maple or oak. „Y 4' CircleTapTM Window 19-10 A R C H I T E C T U R A L D E T A I L F I L E REV.03/05 • a r: e �n se W m d - e;H` irl '.ID o°u b l :. l:T�i, �S<<�h: i•t'J~W'a .g. Joining Details Tilt-Wash Double-Hung, Picture, Transom and Circle Top' Windows for 4-1/2" wall Scale 3" = 1'-0" (1:4) 1-11/1s° (43) 1-11/16" (43) Optional Andersen" Optional Andersen° Double-Hung Double-Hung casing Picture/Transom Double-Hung casing Jamb Jamb Jamb Jamb Optional Andersen° extension jamb p Optional Andersen° Optional Andersen° non-reinforced wood J�; non-reinforced wood ---- i ,--––- joining material � joining material Unit Dim. Unit Dim. Optional Andersen° Unit Dim. Unit Dim. Optional Andersen" trim strip trim strip 1/2"(13) 1/2"(13) Horizontal Section Horizontal Section 1-11/16- (43) -11/16"(43) Optional Andersen® Joining Ctibilt Picture/Transom Picture/Transom casing gom ap y Jamb Jamb Many Andersen®units are designed to be joined with Other Andersen Optional units in a variety of non-reinforced and reinforced combinations.Other Andersen° combination types and joining methods can be viewed in the Andersen* extension z jambs Product Guide for Professionals,in Andersen Window Studio'software, and by visiting www.andersenwindows.com.Combination designs should Optional Andersen° always be checked for desion pressure performance requirements to ,) non-reinforced wood joining material ensure the approoriate ioining_method is specified. Unit Dim. Unit Dim. Optional Andersen° trim strip 1/2"(13) Horizontal Section Picture/Transom/Circle Tor Unit–Sill Picture/Transom/Circle Tor Unit–Sill Optional Andersen" L Optional Andersen" m extension jamb m extension jamb 0 x = 0 - N Optional E Optional Andersen° Optional E Optional Andersen° Andersen" o casing Andersen° o casing trim strip— –� trim strip— 1/2"(13) 0 1-11/16"(43) 1/2"(13) m ! i 1 (43)6" L OL[I bD p Ic O Optional Andersen" Optional Andersen" g non-reinforced wood non-reinforced wood joining material joining material Double-Hung–Head Picture/Transom–Head Vertical Section Vertical Section REV.03/05 A R C H I T E C T U R A L D E T A I L F I L E 19-11 . .. _ , dgO a'ShD0erser TAn �t -WIN - Joining Details - ----------— -- ------------ Tilt-Wash --Tilt-Wash Double-Hung, Picture, Transom,and Circle Topp" Windows with Drywall Return Scale 3" = V-0" (1:4) 1-11/1x'. (43) 1-11/16" Double-Hung Double-Hung (43) Jamb Jamb Picture/Transom Double-Hung Jamb Jamb Optional Andersen° Optional Andersen° casing casing Optional Andersen° f Optional Andersen° }}. non-reinforced wood non-reinforced wood joining material ;---- joining material Unit Dim. Unit Dim. Optional Andersen® Unit Dim. Unit Dim. Optional Andersen° trim strip trim strip 1/2"(13) 1/2"(13) Horizontal Section Horizontal Section 1-11/ls'. Picture/Transom (43) Picture/Transom Jamb Jamb Optional Andersen° Joining Compatibilty casing Many Andersen®units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations.Other combination types and joining methods can be viewed in the Andersen® ( Optional Andersen° Product Guide for Professionals,in Andersen Window Studio software, non-reinforced wood { joining material and by visiting www.andersenwindows.com.Combination desions should i always be checked for design joressure performance requirements to ensure the appropriate joining method is specified. Unit Dim. Unit Dim. Optional Andersen° Unit Dim. U n trim strip 1/2"(13) Horizontal Section - Picture/Transom/Circle TopT Unit-Sill Picture/Transom/Circle Top-Unit-Sill Optional Andersen° Optional Andersen° ;D non-reinforced wood mnon-reinforced wood joining material = joining material hOptional Andersen° y Optional Andersen" casing casing Optional E Optional E Andersen" o Andersen" o trim strip— trim strip— 1/2"(13) - _.- * 1-11/16"(43) 1/2"(13) -_ _-_-- 1-11/16"(43) u u x x o � o N c c m - E E 0 0 Double-Hung-Head Picture/Transom-Mead Vertical Section Vertical Section 19-12 A R C H I T E C T U R A L D E T A I L F I L E REV.03/05 `dere e _ s - V`hD o'u b j"e_`-H"u:n y+j(`h d'b w s. ';.':a; �'i: .W 8 5 Anchoring Methods - ------------------------------------------ --- ------ ---------------- Jamb Clip Threaded Masonry Fastener / Expansion Sleeve Scale 3" = 1'-0" (1:4) Scale 3" = 1'-0" (1:4) I t Double-hung window unit secured in opening by others Double-hung window is secured in the opening by removing the weather- using Andersen'302 stainless steel sheet metal jamb strip and drilling through the side jamb into the masonry. clips and stainless steel screws.Bend the jamb clips to secure unit fit in opening.Installation flange can be cut as required to accommodate the jamb clips. APPLICATION: / • First secure jamb clip to back side of window unitjamb(s) • Apply 1'from corners of head jamb,sill and side jambs • Space jamb clips evenly(maximum distance apart 32"on center) • Jamb clip lateral design load capacity:maximum 200 Ib. Jamb clip C 4 Threaded fastener (furnished by Score markingsfor bending others) 0 xr 0 0 0 O ® t' ® ® 3/16" Make sure that the unitframe parts do not become bowed when using (38). (5) anchoring methods.Unit will not operate properly if frame parts are stressed. 3" (76) REV.03/05 ARCH ITECTU RAL D E T A I L F I L E 19-13 der en rl : An s - :I`e..'H:;ii•'n.. ,.-W�isn,;tl�o;w>S;;'< :;=:��' ..:�-",...�,,;:: �,_::.': DSO„0=fts=:® .T I I t,-W a s.h D`o u b Suggested Product Applications Wall Types Scale 1-1/2” = V-0" (1:8) Remove installation flange Installation at head flange all around Head Head m m = 1/4" _ m m (6' = 1/4„ m a (5) E L nt 0 a E 0 E t _ _ nL m 3 m3 Jamb Jamb 1/2"(13)' minimum Installation flange all around Sill SIII '1/2"(13)minimum to accommodate differential shrinkage/expansion when brick is used with wood framing. Vertical Section Vertical Section Wood Siding/ 2 x 4 Wood Stud Framing Brick Veneer/ 2 x 6" Metal Stud Framing ° m Importance of Proper Installation Proper installation and maintenance of Andersen'products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available }, for Andersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12, Head Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different.Andersen strongly recommends consultation with an Andersen product representative and with m m an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product = 1/4" a ° = Installation of Andersen products,including method of attachment,fastener selection,and code compliance is o (fi) the sole responsibility of the architect,building owner,contractor,and/or consumer. E E L b o Construction by Others 0 0:2 = Andersen Corporation is not responsible forthe design of,conditions in,or performance of,adjacent wall or �3 0 roof construction beyond the perimeter of the Andersen units.Proper integration of the Andersen units with the Jamb weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S.wall finish is adjacent to window units,contact E.I.F.S.manufacturer for installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealant joint around the perimeter of the window. ° ° Membrane Installation s ° flashing over NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. flange all installation Installation flange may be removed where construction sequence/detailing requires no flange. around flange (by others) SIII Vertical Section E.I.F.S. / Concrete Masonry Unit (CMU) 19-14 A R C H I T E C T U R A L D E T A I L F I L E R E V.0 3/0 5 Andersen® wI_Ivo:.ow<su_ooR•s.:® "Telt,:Wa_sh" Do.u,tiIe=Hung Windows. Suggested Product Applications Wall Types Scale 1-1/2" = V-0" (1:8) �\ Optional ® An Existing Optional Andersen° ders ® frame wall Andersen' auxiliary vinyl trim auxiliary casing board casing Lr Installation flange --- - at head and jambs ' Head Head Head i5 up eEa oc m 1/4„ c 1/4„ (6) 1/4" N �6) y u o 0 045 Jamb Jamb Jamb 45 9 xam�ena Remove t Installation Installation installation flange flange flange all around all around at sill Sill Sill Sill Vertical Section Vertical Section Vertical Section Brick/ Concrete Masonry Unit (CMU) Stucco / Concrete Masonry Unit Existing Stud Wall (CMU) Inset Window Optional Existing Andersen masonry wall vinyl trim board. Trim to fit as required. Importance of Proper Installation Finish trimmed edge with -- Proper installation and maintenance of Andersen'products are essential if optimum performance is to be Optional fully attained.Written installation instructions which provide guidelines for proper installation are available Andersen' for Andersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12, rigid vinyl Head channel Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Rememberthat every installation is different.Andersen strongly recommends consultation with an Andersen product representative and with m m an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. = 1/4" m Installation of Andersen products,including method of attachment,fastener selection,and code compliance is (6) = the sole responsibility of the architect,building owner,contractor,and/or consumer. c a o E t - o Y o Construction by Others - 3 Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units.Proper integration of the Andersen units with the Jamb weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S.wall finish is adjacent to window units,contact E.I.F.S.manufacturer for installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealantjoint around the perimeter of the window. Installation flange all around NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange. Sill Vertical Section Existing Masonry Wall REV.03/05 A R C H I T E C T U R A L D E T A I L F I L E 19-15 MODEL NUMBER : RSAH110 081201 NUMBER : 610351101 SERIAL NUMBER : 65525122 as IL CERTIFIE .W FIRING RATE : LT . OIL ( NO . 2 ) 1 . 00 GPH HTG . CAP : 119 MBH NET AHRI RATINGS WATER :103 MBH STEAM : MBH STEAM : r I 1 1 1 S i ui 1 tl U�. - . r • 1�0 ourrnmR' READY "�4 t 'a rRN L 40 ¢q4"" ti a r u w, «� ^Ww�,