HomeMy WebLinkAbout48827-Z �c,�FFOt,f�oG Town of Southold 9/30/2023 o 'd P.O.Box 1179 53095 Main Rd y�j ao� r Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44605 Date: 9/30/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 2934 Park Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 123.-8-17 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/5/2023 pursuant to which Building Permit No. 48827 dated 1/31/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory standby generator as applied for. The certificate is issued to Keller,James&Santisi,Elissa of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48827 9/27/2023 PLUMBERS CERTIFICATION DATED Authorikdw Wature 1,40I.W& TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE Iry • SOUTHOLD, NY Diol .�a�;s BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48827 Date: 1/31/2023 Permission is hereby granted to: Keller, James 95 Joralemon St Brooklyn, NY 11201 To: Install accessory standby generator at existing single family dwelling as applied for. At premises located at: 2934 Park Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 123.-8-17 Pursuant to application dated 1/5/2023 and approved by the Building Inspector. To expire on 8/1/2024. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO-RESIDENTIAL $50.00 Total: $235.00 Building Inspector oF so�ryQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin(Qown.southold.ny.us Southold,NY 11971-0959com �Qly e BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: James Keller Address: 2934 Park Ave city:Mattituck st: NY zip: 11952 Building Permit#: 48827 Section: 123 Block: 8 Lot: 17 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: DAK Electric License No: 5120ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Generator X INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 70A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 10kW Generac Generator 16 Circuit Transfer Switch 8 Used, 200A Panel - 30 Circuit/ 15 Used Notes: Service & Generator Inspector Signature: Date: September 27, 2023 S.Devlin-Cert Electrical Compliance Form soUTy� 0�7 TOWN OFSOUTHOLD BUILDING DEPT. coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PREF C/O [ ] RENTAL REMARKS: DATE INSPECTOR SOUT60� TOWN OF SOUT14OLD BUILDING DEPT. ��y�0UNM0E� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [. ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: e' G cop I 12 ;V-e� . DATE 3'��'0�3 INSPECTOR �1 � _ �♦ - A ��'� r �y ��- '�; '� ��. r Ile PROPANE �A�p�P UN1075 FIELD INSPECTION REPORT I DATE COMMENTS by r FOUNDATION (IST) 00 y ------------------------------------ s C FOUNDATION (2ND) �j z H ROUGH FRAMING& N PLUMBING � ro � � r t� INSULATION PER N. Y. y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS 00 z m k b _ _ y O z Y a x fl =O�oSUFFO(Kel TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�01 �ao�� Telephone (631) 765-1802 Fax(631) 765-9502 hiips://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ® PERMIT NO. / Building Inspector: JAN u 2023r Applications and forms must be filled out in their entirety..lncomplete GUILOONGDEPI applications will not be accepted. Where the Applicant is not the owner,an YIr9W ILDINGDEPT ® Owner's Authorization form(Page 2)shall be completed._ Date: OWNER(S)OF PROPERTY: Name:Jim Keller SCTM#1000- Project Address:2934 Park Ave Mattituck NY 11952 : Phone# il:" _. ,-91.7-587-6746 Ema . __ .._ ... .__._. .._ _. ..._. ._ ._.. _ ..J!mkeller321 @gmail.com Mail ingAddress: � CONTACT PERSON: Name:Jesse_Gaffga _. _ Mailing Address:3350 Grand Ave Mattituck NY 11952 Phone#:631-375-2737 Email:jgaffga@jteChss.COm DESIGN PROFESSIONAL INFORMATION: ' Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:J-Tech Mailing Address:3350 Grand Ave Mattituck NY 11952 P one 631-375-2737. _......_..... . _... EmanI.:J9aff9a.@Jtechss.com DESCRIPTION OF PROPOSED CONSTRUCTION . ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOtherStand By Generator $10000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION , Existing use of property:$Ingle.fam.11_y..,, _ Intended use of property:Single Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. B Check Box After Reading:. The.owner/contractor/design professional is responsible for.all drainage and storm water issues.as provided by, Chapter 236"of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance.of a'Building Permit pursuant to the-Building Zone•:, .A►dinance of the Town of.Southold,Suffolk;County,New York and other applicable laws,Ordinances or Regulations,for the construction of buildings, . r additions,'alterations or for removal or demolition4s;herein,described.The applicant agrees to comply with all applicable.laws,ordinances,building code,' 'housing cade.and regulations and to admit authorized inspectors on premises and in buildirig(s)for necessary inspections.-False statements made herein are punishable as a Class A misdemeanor npursuarifto Section 210.45 of the New York State Penal Law. 1 ,.1111 iji,.:f, • Application Submitted 'y(print name):Jesse Gaffga (Authorized Agent ❑Owner _._... _. ._ _._..... . __ _ . _. . . .8 .... Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Jesse Gaffga being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contactor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 3�a�3� ,20-27— A4�1 Bruce L.McDonald Notary Public NOTARY PUBLIC,STATE OF NEW YORK Registration No.01 MC6224291 Qualified in Suffolk County ROPERTY OWNER AUTHORIZATION Commission Expires June 28, 20 (Where the applicant is not the owner) I, `� 1 Nl Y 'ARA— residing at J� � � kv- � a ac do hereby authorize Jesse Gaffga to apply on my behalf t t e T n of Southold Building Department for approval as described herein. 7-1-ZZ ne Signature p Date V\kJ Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector yam► TOWN OF SOUTHOLD ® '` Town Hall Annex- 54375 Main Road - PO Box 1179 co • Southold, New York 11971-0959 'j�j Off' Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrasoutholdtownny.gov— seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 9-1-22 Company Name: DAK Electrical Electrician's Name: Dave King License No.: m-5120 Elec. email:Jgaffga@jtechss.com Elec. Phone No: 631-375-2737 ❑I request an email copy of Certificate of Compliance Elec. Address.: PO#1050 Mattituck NY 11952 JOB SITE INFORMATION (All Information Required) Name: Jim Keller Address: 2934 Park Ave Mattituck NY 11952 Cross Street: Phone No.: 631-375-2737 BIdg.Permit#: email: Tax Map District: I 00b Section:123 Block: 8 Lot:17 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): new generator and service Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES❑V NO Issued On Temp Information: (AII information required) Service Size❑1 Ph R Ph Size: A #Meters Old Meter# ❑New Servicer-1 Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 0 1 2 D H Frame Pole Work done on Service? D Y FIN Additional Information: PAYMENT DUE WITH APPLICATION ;t� 7 � � Electrical Inspector F BUILDING DEPARTMENT TOWN OF 50UTHOLD } Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 ® p , Telephone (631) 765-1802 - FAX (631) 765-9502 ro err southoldtownn ov - seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 9-1-22 Company Name: DAK Electrical Electrician's Name: Dave King License No.: m-5120 Elec. email:Jgaffga@jtechss.com Elec. Phone No: 631-375-2737 0 request an email copy of Certificate of Compliance Elec. Address.: PO#1050 Mattituck NY 11952 JOB SITE INFORMATION (All Information Required) Name: Jim Keller Address: 2934 Park Ave Mattituck NY 11952 Cross Street: Phone No.: 631-375-2737 Bldg.Permit#: 1 email: Tax Map District: 1 0ob Section:123 Block: 8 Lot: 17 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): new generator and service J Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES R NO EJ Rough In E] Final Do you need a Temp Certificate?: 1-1 1 YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 PhF-]3 Ph Size: A #Meters Old Meter# ❑New ServiceOFire Reconnect[]Flood Reconnect[]service Reconnect[]Underground Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y F1N Additional Information: PAYMENT DUE WITH APPLICATION " Survey of Property WE ¢�N { m Prepared for: Jim Keller s K+. 0 n �O w N 'Surveyed:June 6, 2007 w� Garel SCT# 1000-123-8-17 + Town: Southold Suffolk County, W 52.0 PFnd 1'-=3Y l 9 k.A `0 Reference Deed G 1 Liber 121,45 Page c187 Q flADne Lot Area = 0 2-1 Acres 1 0 dea 9°tg l cre� fS W w - 10 50V F° 1 9 1►� 1 00 O� O Im ' °, � �'►10' ' Desk 5tep5 1 � . 1 e OOFfy yto^ e' 1 �x •, ri, ---------- -, Q°o tlmbgpd timbe 1 ea0 ttmbe�bulkhead JX0 107 r - o. .01 b OO g ,� L 1MNeorete+O ellerabn or a6dltai N c ruvey - �g�33 - _-_-- -- -t - - mcp t»orog o I Wn.d tvd•+r•P«a wt —$ %' vbbtbn of Mctk+n 7204 a+buvbbn 2,oe w�ratsea.r�amlar ----^— 5 •�+ — • �J Non �k 5COt,�N.agt�of u. ROBERT H.FOX pl.Itdl E7..11-- rH W t� eop�lq' S NYS PLS#50197 � a w, peconie eay Po�°X#� �� •..Sa a c.tarot ore.�� aNy W 11931 w t,•pe non for rham 1,r every r FIM—L od On hb bMu�bvUgr toV capoy, gv.�n. — 53.1-722-M b Ilv tern of tF.�4ro�ig�eYentnul_ ebrtr 'U10r1007 -4.37.50PM ttarr a•not erort.:�•to monwnt rstnutae C.A LMtkelbrpro APPROVED AS NOTED _ DATE: ' l a3 B.P. a 'JCCUPANCY OR FEE j3L!5-_09 BY: USE IS UNLAWFUL NOIFY ING DEPARTMENT AT 631T-765-1802 D8AMT0 PM FOR THE WITHOUT CERTIFICATE FOLLOWING INSPECTIONS: OF OCCUPANCY 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OFTHE CODESOF NEW COMPLYWITH ALL CODES OF YORK STATE. NOT RESPONSIBLE FOR NEW YORK STATE & TOWN CODES DESIGN OR CONSTRUCTON ERRORS AS REQUIRE AND CONDITIONS OF SOUTHOLD TOWN ZBA SOUTHOLD TOWN PIANNINGBOARD SOUTHOLD TONIN TRUSTEES N.Y.S.DEC RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. 1 GENERAC° !10 3/16, kW GUARDIAN° SERIES Residential Standby Generators Air-Cooled Gas Engine 1 , INCLUDES: Standby Power Rating G007171-0,G007172-0(Aluminum-.Bisque)—1 O kW 60 H�<_ • True Power" Electrical Technology G007173-0,G007174-0,G007175-0(Aluminum-Bisque)—13 kW 60 Hz G007176-0,G007177-0,G007178-0(Aluminum-Bisque)—16 kW 60 Hz • Two-line multilingual digital LCD Evolution- controller (English/Spanish/French/Portuguese) • Two transfer switch options available: 100 amp 16 circuit switch or " 200 amp service rated smart switch • Electronic governor x -,,.. j • Standard Wi-Fig'" connectivity • System status&maintenance interval LED indicatorst • Sound attenuated enclosure GENERAL;' p • Flexible fuel line connector • Natural gas or LP gas operation T, , • 5 Year limited warranty ,,` •, • Listed and labeled by the Southwest Research Institute 'Lus 0 allowing installation as close as 18 in (457 mm) to.a �E�r or C( UD n� /' — mows * LISTED u[lJ structure. WE *Must be located away from doors, windows,and fresh air Note:CETL or CUL certification only applies to unbundled units and units packaged with limited intakes and in accordance with local codes. circuit switches.Units packaged with the Smart Switch are EfL or UL certified in the USA only. https:llassets.swri:orgllibraryIDirectoryOfListedProductsl Constructionlndustryl9737DoC 204_13204-01-01_Rev9.pdf FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This Generac's success in providing the most reliable generators possible.Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac Force engine lineup offers added peace of mind and reliability for when you need it models. It provides optimized FAST RESPONSE to changing load conditions and the most.The G-Force series engines are purpose built and designed to handle the MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the rigors of extended runtimes in high temperatures and extreme operating conditions. surge loads to the engine.Digital voltage regulation at±1%. O TRUE POWER'"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit, from the engine to the allows confident operation of sensitive electronic equipment and micro-chip based smallest electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MGI-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer,systems and controls for total system compatibility. O MOBILE LINK'"WI-FI CONNECTIVITY:FREE with select Guardian Series home standby generators, Mobile Link Wi-Fi allows users to monitor the status of the generator from anywhere in the world using a smartphone,tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. A OMISE �®�` '•�' I GENERAC® 10/13/16 kW .Features and Benefits Engine r • Generac G-Force design. Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-IW,cast iron.cylinder walls Rigid construction and added durability provide long engine life:: • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,Mess maintenance,:and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. , • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator - • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. . • NEMA 311 Can be installed inside or outside for maximum flexibility, • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution TM Controls •.: AUTO/MANUAL/OFF illuminated buttons Select the operating mode and proyide.easy,at-a-glance status indication in any condition. • Two-line multilingual LCD ..Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropiut,80%0,pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine,adjustable 2--1500 seconds from the factory default setting of - 5 seconds by qualified dealer. • Engine warm-up Verifies engine is ready to assume the load.Setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown.Setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation,providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. •' •Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection;against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is'mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. ` GENERAC® .10/13/16 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Ability to view generator status Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due. Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAL® ' 10/13/16 AW Specifications Generator Model G007171.0,6007172-0 13007173.0,G007174-0, G007176.0,G007177.0, (10 kW) G007175.0(13 kW) G007178.0(16 kW) Rated maximum continuous power capacity(LP)�` _ _ _ - _ _ 7 10V000 Waris' 13,000 Watts"s' '� 16,000 Watts"f Rated maximum continuous power capacity(NG) _ 9,00D Watts` 13,000 Watts' 16,000 Watts" Ratedaltage._ _ - r Rated maximum continuous load current-240 volts(LP/NG) 41.7/37.5�- 54.2/54.2 66.7/66.7 .� ToialHarmonicDistortion - _.. _:]` ,..- >_ _ . _"'_• of Main line circuit breaker �� 45 Amp 60 Amp 70 Amp �Phal sem_ �� - �. • � .,- �-__-__a_ T� - Y - Number of rotor poles _ .2 _ Rated :60 Hz- �_ r _J Power factor _ _ _ 1.0 Battery requixemenf(not included] �Y � Y -�, _ ���W 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum,�� _ Unit weight(lb/kg) 338/15_3 385/175 420/191 _ bimensions(LxWxH in/cm, - � - � y,;Y�- '48�x253.5x73.7 ,x291121.9x6 `Sound output in dB(A)at 23 it(7 m)with generator operating at normal'load"`M 61 65 _ 65 `$Onn(J output in dB(Aj at 23 ft(Z m),with generator inQui'efTesl'""low-speedrercise mode'"' " 57 55' .. ���'`•�'55w� Exercise duration 5 min Engine Engine type _ _ G_ENERAC G-Force 400 Series _ GENERAC G-Force 800 Series == Displacement 460 cc 816 cc °Clinderblack' _' ''� _'�_'-'-'�' �y _ t,.. , ..,,�,,. �: '�. ,° �,: Valve arrangement- - v Overhead valve "'"�""-"'".-_-_..._...-_•._ _ ydra is '� Litter,type �.a." _..�.._.w.-...._._. -.'_��v.___._._ •._..�.._._..:.Solld,•:, -,..,_;.FI ul.._._`'.�"_-_ Ignition system Solid-state w/magneto Governorsystem Electronic. ' _ Compression ratio- 9.5:1 Starter: _� 12-NDC _ •_.._ Oti capacity including filter Approx.1.1 qt/1.0 L Approx 2.2 qt/2.1 L Operatidg epm _ 77_, 00.__3,6 � Fuel consumption Natural Gas ft3/hr(m3/hr) 1/2 Load 101(2.86) 154(4.36) 182(5.15) Full Load 127(3.60) 225(6.37) 245(6.94) Liquid Propane fts/hr(gal/hr)[Uhr] 112 Load 36(0.97)[3.66] 56(1.54)[5.83] 62(1.70)[6.45] Full Load 54(1.48)[5.62] 90(2.45)[9.28] 109(2.99)[11.32] _____.._ Note:.Fuei pipe must be sized lartull Ioad..Required fuel pressure to generator fuel in et al i'all load ranges.=3.5 7:0 in water column kRaj for NG,.10=12"in water column(2.49-2,99 kPa)for LP gas. For BTU content,multiply fh1/hr x 2,500(LP)or fta/hr x 1,000(NG).'For Megalaule content,multiply m3Por x 93A 5(LP)or m3/hr x 37.26(NG). Controls tTwo-Pirie plain text `Simple usecinterface for ease of operation. Mode buttons:AUTO _ Automatic start on utility failure.Weekly,Bi-Weekly,or Monthly selectable exerciser. ��y MANU_AL _�_ �~�_'������_�� � �_ ��'Start with ster[e�canhol,u_nis stays on.If utility fails,transfer so.loae lakes�playce. ��; �__ Stops unit.Power is removed.Control and charger still operate. =Ready.to RuNNltintenance messa9os v_ _ _._ . w __ �_ w Standard Engine run hours indication Standard [Progiammable start delay behveeri 2-1500 seconds T tandaed(programmable by dealer onlyp 3_] Utility voltage loss/Return to utility adjustable(brownout setting) w -- From 140-171-V%190-216 Vw _ -n - _ ..- F —wr �,- _,---�---_-..... - Future'seicapable exerciser/Ezercise selerror warning" .- t t .Stan'dard;",, Run/Alarm/Maintenance logs - 50 events each- Engine stasequence � � " r .�. Ma w�— Cyclic cranking�16 sec on,7,sec r0_(§0 see matnmum durafionj�� m Starter lock-out ___ Starter cannot re-engage until 5 sec after engine has stopped. FSmait Battery Charger .- _. _. ._. ..," Charger Fault/Missing AC Warning Standard (Low BatterylBattery,probtem'Protection and Battery Condition Ind[cation; :Stand_a�d' ' . .--J Automatic Voltage Regulation with Over and Under Voltage Protection Standard ;Under-Fiequen_cy/Over oad/5te_pp_er Overcurrent Prcte lc fon'�'� ��"'�"�;t` Standard • �-''� '��' Safety Fused/Fuse Problem Protection _ Standard _ A'dtomstiC LLow Oil Pressure%Fligh 011 Temperature Stiutdown. 4 �� __ _ _ Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown uStandard High Engine Temperature Standard _Y, Internal Fault/Incorrect Wiring Protection - - � � �- - w J Standard - Common Re_F6 lFault Capability - W -�� 3taridard Field Upgradable FirmwareStandard "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available tar this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271)..Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU(Megajoule)content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level;and also will decrease approximately 1%for each 6°C(10°F)above 16°C(60°F). GENERAC® 1.0/13/16 kW Available Accessories _ Model# Product .DesTP cription _ ._ _ G005819-0 26R Wet Cell Battery 6,Every standby generator requires a battery to start the system Generac o ers the recommended 26R wet cell) battery for use with all air-cooled standby product(excluding PowerPact ). G007101-0 Battery Pad Warmer The pad warmer rests under the battery.Recommended for use if the temperature regularly falls below 0 IF(-181 °C).(Not necessary for use with AGM-style batteries). G007102 0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below 0 IF(-1.8� C). G007103-1 Breather Warmer The breather warmer is for use in extreme cold weather applications.For.use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auwliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you' Contact Kit may not need.Not compatible with 50 amp pre-wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a sleek, G007027-0-Bisque Fascia Base Wrap Kit contoured appearance as well-as offering protection from rodents and insects by covering the lifting holes lo- cated in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future 99 corrosion.The paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006482-0—10 kW Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance G007216-0—13It 16 kW Scheduled Maintenance Kit on a Generac automatic standby generator(oil not included). The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel.tank.Monitoring G007005-0 Wi-Fi LP Fuel Level Monitor the LP tank's fuel level is an important step in.verifying the generator is ready.to run.during an unexpected power failure.Status alerts are available through a free application to notify users when the LP tank Is in need of a refill. G007000-0(50 amps) Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages G007006-0(100 amps) Smart Management Module large electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using p SMM's can reduce the overall size and cost of the system. ! The Mobile Link 413 LTE Cellular Accessory allows users to monitor the status of the generator from anywhere,, G007169-0 I Mobile Link-413 LTE Cellular in the world,using a smartphone,tablet,or PC.Easily access information such as the current operating status Accessory and maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. Dimensions.& UPCs 637.6 mm [48.0 inl Model UPC [25.1 In] G007171-0 696471074680 G007172-0 696471074673 G007173-0 696471076400 727.2 mm IN.6 In) G007174-0 696471077100 G007175-0 696471077117 G007176-0 696471076417 o v o 0 G007177-0 696471077124 646 mm 1232 mm G007178-0 696471077131 25.5 In] 146.5'"' LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. • S45 W29290 HWY.59;Waukesha,WI 53189 4 gen erac.com 02019 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.10000033190 Rev.A 07/26/19 GENEgAC" 10/13/16 W Switch Options Limited Circuits Switch Features Model . 0007172-0 G007174-0 G007177-0 (10 kW) (13 kW) (16 kW) • 16 space,24 circuit.Breakers not included. eeN�o of';polesf ,2{' ,-r: 4 Electrically operated,mechanically-held contacts for fast,positive connections. tCurren ratingmps) �' ` Current rating(amps) 100 • Rated for all classes of load,100%equipment rated,both inductive and - -- ° Voltagesrating;{VACZ ., ;;:120.- W:.v,.%2A0,.10' � resistive. v. ' Utility voltage monitor(fixed)" • 2-pole,250 VAC contactors. -Pick.-up 80% • 30 millisecond transfer time. -Dropout 65% • Dual coil design. --- . ,,°_-. -�—�-A M,. APP`rox—A5_sec<�.: • Rated for-both copper and aluminum conductors. Exercises bi-weekly for Standard • Main contacts are silver plated or silver alloy to resist welding and sticking. 5 minutes* .• NEMA/UL 311 aluminum outdoor enclosure allows'for indoor or outdoory*R `-7117 4 mounting flexibility. ETC'or: Wei L ; .' .:::::. '.:.::;,;;.' A::." : StantlaFd y;::.`' = Total circuits available 24 • Multi listed for use with 1 in standard,tandem,GFCI;and AFCI breakers from 7 7— Siemens,Murray,Eaton,and Square D for the most flexible and cost effective Tandem bjeaket;capafiilihes_ ,.,„ ��.; 8.rtandems _ install. Circuit breaker protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts Dimensions *Function of Evolution controller Exercise can be set to weekly or monthly Height Width W,— H1 H2 W1 W2 Depth in 26.75. 30.1 10.5 13.5 6.91 cm 67.94 76.43 26.67 . 34.18 17,54 Wire Ranges "` "z " H, Conductor LugNeutral Lug Ground Lug 2/0-#14 2/0-#14 2/0-#14 Derr" i--Wz--I Service Rated Smart Switch Features Model 0007175-0' 0007178-0 • Includes Smart A/C Management(SACM)module standard. (13 kw) (16 kW) Ymanages • Intelligently uP to four air conditioner loads with no additional g.;,.v,,P..�,.� d�G;;:',�,�_-.•,";; ..."� -�-'' '- hardware. Current rating(amps) 200 • Up to eight large(240 VAC)loads can be managed with Smart ManagementVoltage°rating`,(VACj Modules(SMMs). Utility voltage monitor(fixed)* • Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80% • Rated for all classes of load,100%equipment rated,both inductive and -Dropout 65% resistive. �Retum#u'ufili � • 2-pole,250 VAC contactors. Exercises bi-weekly for 5 minutes' Standard • Service equipment rated,dual coil design. ETL or ULisretl v� M .: Standard : wm • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. r "� - • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Lug r . Lug range 250 MCM-#6 mounting flexibility. *Function of Evolution Controller Dimensions Exercise can be set to weekly or monthly W, 200 Amps 120/240,10 Open Transition Service Rated Height Width Depth H1 H2 W1 W2 t` in 26.75 30.1 10.5 13.5 6.3 cm 67.94 76.45 26.67 34.3 16.01 H2 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400 MGM-#4 350 MCM-#6 210-#14 oEr,r'N 1 W2'-