Loading...
HomeMy WebLinkAbout29515-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-29815 Date: 11/03/03 THIS CERTIFIES that the building APARTMENTS Location of Property: 1000 NINTH ST GREENPORT (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 46 Block 1 Lot 31.1 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JUNE 20, 2003 pursuant to which Building Permit No. 29515-Z dated JUNE 24, 2003 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is MODULAR APARTMENT BUILDING (2 UNITS) AS APPLIED FOR. The certificate is issued to DRIFTWOOD COVE CO OWNERS INC (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF BEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 1169605 10/24/03 PLUMBERS CERTIFICATION DATED 10/21/03 HARDY PLUMBING & HEATING 41 Authorized S' nature Rev. 1/81 FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY NO: Z-29818 Date: 11/03/03 THIS CERTIFIES that the building APARTMENTS Location of Property: 1000 NINTH ST GREENPORT (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 46 Block 1 Lot 31.1 Subdivision Filed Map No. Lot NO. conforms substantially to the Application for Building Permit heretofore filed in this office dated JUNE 20, 2003 pursuant to which Building Permit No. 29515-Z dated JUNE 24, 2003 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is MODULAR APARTMENT BUILDING (6 UNITS) AS APPLIED FOR. The certificate is issued to DRIFTWOOD COVE CO OWNERS INC (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 1169605 10/24/03 PLUMBERS CERTIFICATION DATED 10/21/03 HARDY PLUMBING & HEATING Authorized Si 92,41ure Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29515 Z Date JUNE 24 , 2003 Permission is hereby granted to: COVE CO OWNERS DRIFTWOOD PO BOX 256 SHOREHAM,NY 11786 for FIRE REPAIR/RECONSTRUCTION & REPLACEMENT INKIND OF EIGHT DWELLING UNITS AS APPLIED FOR at premises located at 1000 NINTH ST GREENPORT County Tax Map No. 473889 Section 046 Block 0001 Lot No. 031 . 001 pursuant to application dated JUNE 20, 2003 and approved by the Building Inspector to expire on DECEMBER 24, 2004 . Fee $ 1, 492 . 40 A th ized Si re COPY Rev. 5/8/02 Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 till 12 8 2003 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Swom statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial $15.00 Date. New Construction: ✓ Old or Pre-existing Building: (check one) Location of Property-J66-7-3 "ion 9""U/Xee_r C7-reely�p,�" House No. / Street Hamlet Owner or Owners of Property:�t hLW 0,bYe ©L(-)Irf5 z;10— Suffolk County Tax Map No 1000, Section Ll tp Block Lot �. 1 Subdivision // I Filed Map. Lot: Permit No. Z�S 5 Date of Permit. l0 _2 -03 Applicant: ]X OZ Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: 4 6D 11 Applicant Signature - rep?9-g�g,C- ,6 .b . i�. O rJ�rJ�rJ��n�Pr��l arJ�rJ�rJ�rJ�cncPrJ arJ�r�r1rJC ncnrla�Pr3r3-3jrJ�CJ-C3j9rrJ@rarJ ar�rJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�r nr rrJ arJ ar�r��In Marc RINCNCIPEPrJNCIPCI J@PrJ@P Co 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 BUREAU OF ELECTRICITY S 5 40 FULTON STREET — NEW YORK, NY 10038 5 CERTIFIES THAT 5 Upon the application of upon premises owned by 5 DANIEL WILCENSKI ELEC.CONTR. DRIFTWOOD COVE OWNERS INC. 5 5 P. O. BOX 319 315 WIGGINS ST �5 7C7C7C5 SOUTHOLD, NY 11971, GREENPORT, NY 11944 5 Located at 315 WIGGINS ST GREENPORT, NY 11944 5 Application Number: 1169605 Certificate Number: 1169605 55 5 Section: Block: Lot: Building Permit: BDC: NS11 5 Described as a Residential occupancy,wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 First Floor,Outside, 5 5 5 was inspected in accordance with the National Electrical Code and the detail of the installation, as set forth below, was 5 rj found to be in compliance therewith on the 24th Day of October,2003. 5 5 Name OTY Rate Rating Circuit TyRe 5 5 Miscellaneous 5 5 4-modular units with 5 rj 2 apartments each Crj 5 N.Y.State approval#19-2145 8 Lj 5 MFG-Sun Building Systems 5 serial#2579 �5 5 N.Y.State approval#19-21457 5 P] serial#2578 rj C5J N.Y.State approval#19-21456 5 5 5 serial#2577 5 N.Y.State approval#19-21459 5 serial#2580 MService 5 5 1 Phase 3W Service Rating 600 Amperes 5 rj Service Disconnect: 6 100 cb fj Meters: 6 5 sea! 5 5 5 1 of 1 55 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. P51 OrJ�rJ�J a�PrJ�cJcPr�rJ�rJrJrJr�rJr�cPr��fd�cPrPiJrJrJrJr�rJ arJ arJr�rJr�rJrl�PcPrJrJrJrJrJ arJrJrJ�rJcPrJrJ acPrJ arJ arJ arJrJrJ�rJ arJ arJ arJ arJrJ arJ arJ'aEU 1111 TEL. 765-1802 TOWN OF SOUTHOLD OFFICE OF BUILDING INSPECTOR P.O. BOX 1179 TOWN HALL SOUTHOLD, NY 11971 CERTIFICATION -7 Date: a I Building Permit No. dq� G— Owner:)-)YI�+ OnUC lease prin Plumber: a Yf�1 L,� U mbI nQ (pleas int) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. I also certify that I installed an anti-scold and/or thermal shock preventing device at all bathing and/or showering fixtures in conformance with part 902.6(k) of the NX.S.F.P.A.B.C. lumb s signature) Sworn to before me this 3!_ day of O('_-frr -3060-(300 t) F (Notary Public) Notary Public, s�U��O k County JESSICA BACKHAUS Not&YN BA8087fNowY k Ouellfled M Suffolk Courtly ComnYseioo Expires 02/12a I /zlr TOWN OF SOUTHOLD PROPERTY RECORD CARD ' OWNER STREET VILLAGE DIST. SUB. — Yf4f)M 5 FARMER OWNERF+kX oMst. �ore�. N ` �tS6, � S'!t J h u'� '' ' A N': Al 1 E ACR �� W TYPE OF BUILDING L )ANO RES. �J SEAS. VL FARM COMM. CB. MICS. Mkt. Vol Q4 LAND IMP. TOTAL DATE REMARKS s' fig ''z. � d t� a. fe Q� C3An Sti is Far 7e, t ! ado - Oooc7 .toxo - HXcews foDblt wror� ! , ,-��^ F7'9419T4 s-noo ``)� pOd'' Ulo 00 n C4 0 00 I f �Q� / 76 ify Oyf ty 19(nCS9Z0 , I ac o opo 90OOD 000 B �- q g 3 Iwo Tillable FRONTAGE ON WATER Woodland FRONTAGE ON ROAD Meadowland DEPTH House Plot I BULKHEAD Total BUILDING PERMIT EXAMINER CHECKLIST /� DATE REVIEWED: L Z2111 03 APPLICANT jXLprU,j0j C �► ►SPS Ili+ DATE SUBMITTED: �/ 3 SCTM#DISTRICT: 1,000, SECTION: , BLOCK: / , LOT: 31 / SUBDIVISION: ADDRESS1000 244 cif• CITY: ZONING DISTRICT: 40 _ CONFORMING? XS BUILDING PERMITS OPEN/EXPIRED: PRE CO: Y OR N BP .2S6I3 -Z! c/o Z-2GS4 , INFOjjee A-g IBPett6 -ZICIOZ- . Z INFO e/�c /ept�Ji BP2 x66'1 -Z/C/0 z--2r,4 i , INFO ftRA-M.A-`l I BP -Z/C/0 Z-vp�, INFOZ&YA SINGLE & SEPARATE CERTIFICATION-REQUIRED NOTES: I LOTS 40,000SF-100-24.Lot mcognitiona(CREATEDbefnre June 30, 1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at any time after 7/1/83 V'4 104'01e.B I'V' r/A) REQ. LOT SIZE: ACT. LOT SIZE: REQ. LOT COV. ACT. LOT COV. REQ. FRONT PROP, FRONT REQ SIDE ACT. SIDE REQ. REAR PROP. REAR REQ. HEIGHT PROP, HEIGHT PROJECT DESCRIPTION: f + ESTIMATED PROJECT COST. 43 ARCHITECT : 5i u 17..�y,�l� 004 VV ODUt. � WATER FRONT? X° DESCRIPTION: PANEL # FLOOD ZONE: APPROVALS REQUIRED SUFFOLK COUNTY HEALTH DEPT: YES or(aBED #): _DTE: _/_/^ PERMIT#: TOWN SEPTIC RECEIPT: Y NEW YORK STATE DEC: PRE-DEC 9nY7s YES or DTE: I PERMIT #: SOUTHOLD TOWN TRUSTEES: YES or DTE /_/_ PERMIT#: TOWN ZONING BOARD APPROVAL: YES o DTE: !_/ PERMIT#: TOWN PLAN. BOARD APPROVAL: YES or DTE /_/_ PERMIT #: TOWN HISTORICAL PRE (SPLIA): YES o O NEW YORK STATE CODE COMPLIANCE (SEE PAGE 2): YES or NO NOTES: FEE STRUCTURE: FOUNDATION: Cts( SF FIRST FLOOR: 71){n`)l _SF SECOND FLOOR: $7a1 SF OTHER: �SF INIT OTHER TOTAL TOTAL: 153 67--SF FEE FEE FEE 4a 1. SF)- ( 400 SF)= y'4% SF X $,10 _$X29 7�0+$ 2oo +$ =$Ju 9 2 2. (-SF)- CSF)= SF X $-4—+$_+$__ $ 3. (—SF)- ( _sF)= SF X $—=$—+$—+$ =$ p FINAL TOTAL: $ 112 NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: Ground Snow Load: 45 Wind Speed: 12OMPH ✓ Seismic Design Category: B ✓ l Weathering: Severe Frost Depth: 36" `Termite:M-H Decay: S-M Design Temp: 11 Ice Shield Underlay: YESFlood Hazards: (/ USE/OCCUPANCY CLASSIFICATION: W 0LTI- F1°I I L`1 HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: 5I� DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS6)/N HEADERS: Y/N WALL STUDS: Y/N GIRDERS: YIN CEILING JOISTS: Y/N FLOOR JOISTS: Y/N ROOF RAFTERS: Y/N LUMBER SPECIES AND GRADE: Y/N DESIGN LOAD CALCULATIONS:01, LIVE:Y/N DEAD: Y/N SNOW: Y/N SEISMIC: Y/N WIND: Y/N WINDOW AND DOOR SCHEDULE: mISSLE TEST 11QUIREMENTSaN EGRESS 5.7 S.F.: N LIGHT 80/o/ VENT 4%. N NAILING/CONSTRUCTION SCHEDULE: Y/N— MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: Y/N TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) STATE OF NEW YORK DEPARTMENT OF STATE 41 STATE STREET ALBANY, NY 12231-000I GEORGE E, PATAKI RANGY A. DANIELS GOVERnOR January Y7 2003 SECRETARY OF STATE Mr, Tom Stephenson J 11/ i J Sun Building Systems, Inc. 9 Stauffer Industrial Park Taylor,PA 18517 `SIA FACSIMILE TRANSMITTAL RE: M 0052-02-062 Dear Mr. Stephenson: System approval- CONDITIONAL Issued herewith, in response to your October 15,2002 application for approval of a Detached One- and-Two-Family Dwellings,and Multiple Single-Family Dwellings(Townhouses)System of Models is Factory Manufactured Building Approval designated M0052-02-062,as authorized under Part 1281 of the Uniform Fire Prevention and Building Code. Buildings manufactured under this approval are limited to installation on sites meeting the following criteria: 1. The Seismic Design Category as determined by geographic location and soil Site Class is limited as follows: Ia. Seismic Design Category A, B, or C for Detached One-and Two-Family Dwellings, lb. Seismic Design Category A or B for Multiple Single-Family Dwellings (Townhouses). 2. The basic wind speed of a locality is no more than 120 mph. The project site is limited to Exposure Category A,B,or C within the design wind speed. Exterior windows and doors shall be designed to resist the design wind loads specified in Table R301.2(2)adjusted for height and exposure per Table R301.2(3). Provisions regarding Wind - Borne Debris Regions will be completed on-site by others and is subject to the approval of the local code enforcement official. 3. The ground snow load is not in excess of 85 psE 4. The discrete models derived from system are restricted to non-electric heating system; only. as determined in the Residential Code ofNew York State(RCNYS) and/or Building Code of New York State, an inclusive volume of the Uniform Fire Prevention and Building Code (Uniform Cod incorporated wholly by reference, Www.DOS.STATE.Nr.US • r-MAIL'. INFO@005.STATE.NY.US Mr. Tom Stephenson January 17, 2003 Page 2 Supplemental Conditions of Approval In addition,the conditions under which system approval is granted are: 1.The manufacturer is to submit to the Division a duplicate of the permit set for each dwelling to be installed in New York State. Each permit set is to be sealed and signed by an architect or engineer registered in New York State and is to bear that architect or engineer's certification that"the plans and specifications of the permit set are derived from and consistent with the plans and specifications associated with this approval on file with the Division and this conditional approval letter." The certifying architect or engineer may not be affiliated or associated with the manufacturer's quality assurance agency. The following are specific requirements regarding the contents of the permit set. 1.1. A set of drawings comprising at a minimum: 1.1.1 Cover sheet which contains information on: -Project location -Design criteria: listing of applicable design loads such as Ground Snow Load, Seismic Design Category, Wind Speed, Live Loads, Dead Loads,etc. -Applicable building codes and design specifications - Energy code information: statement by professional of compliance with Energy Conservation Construction Code ofNew York State, 2002 Edition. Method of compliance and pertinent documentation shall be provided. -Occupancy classification - Construction type classification - General notes -Index of drawings -Manufacturer's title block -Certification, by design professional, of derivation from approved system set drawings and this conditional approval letter 1.1.2 Elevations 1.1.3 Floor plans which convey the information on: - Required and provided light, ventilation, egress, window and door schedules -Unambiguous identification of structural members - Smoke detectors and GFC Interrupt protection 1.1.4 Foundation plan 1.1.5 Building cross section with information on: - Building integration(module connections) details - Location of required fire stopping Roof truss bracing and structural connections 1.1.6 Roof system -Special requirements addressed(such as sliding,drifting or unbalanced snow load conditions) 1.1.7 Non-typical details (such as prow roof, cantilever beams, etc.) 1.2 Summary of references to system for selection of structural members. 1.3 Each page of drawings and calculations should be signed, sealed, and dated by New York State registered design professional. 2. The manufacturer will submit a weekly report summarizing (listing) all permit sets with information about project location, production serial number, and NYS insignia number. 3.The manufacturer will promptly address the deficiencies of submittals. Mr. Tom Stephenson January 17, 2003 Page 3 4.The system conditional approval is subject to termination upon evaluation of compliance with the provisions of the Uniform Code. 5. The Division will conduct quality control review of permit set submittals to evaluate compliance with the above conditions and with the provisions of the Residential Code of New York State_ Deficiencies will be reported to Manufacturer name and are to be promptly addressed. The approval is indicated by the New York State Department of State"Stamp of Approval'placed on the accompanying set of plans. The reconciliation of fees associated with this approval is provided as an attachment to this letter. A copy of this letter,without attachment,shall accompany each set of plans submitted for a building permit and be deemed a duplicate original. Sincerely, George E. Clark,Jr. Director Division of Code Enforcement and Administration Enclosure cc: Kevin White, TRA & Associates,Inc. File 02-062CAL.wpd HEAT LOSS CALCULATION __ Model: TotaIIBTUH bsr 3169 - � _.- -. ._ - DUPLEX _-_ Length 19 83 49620 35 _ State NY Width 31.08 - - - - of glazing= -0.6 Date: 6-13-03 - - r IL _ Rev. 3169 B Design temperatures R-value - tt�� - - - Interior 70 - deg F --- - Floor. 19 EMerior 8 deg F _Wall: 19 -- - - - Temperature Diff. 78 ;deg F T ++ Roof: 38 Crawl space -8 deg FE Clg. Ht.: 8 Temperature Diff. 78 deg F #of flys: 2 Note:temperatures are based on dry bulb reading _ €-'-Mjjraa U door(entry) 0.21 �- Electric BB watts/ft= 225 U door(patio) 0.34 Hydronic BB btuh/ft= 5.30 U window 0.31 U wall - 0.052 U roof- 0.026 Electric toe kick heater= 1500 watts U floor 0.052 Hydronic toe kick heater=3300 btuh s rt/kit-1&4 bath-1&4 br-1&4 rt/kit-2&5 bath-2&5 br-2&5 rt/kit-3&6 bath-3&6 br-3&6 n/a 7 - - Area t.wall _ 51.3 11.8 40.1 51.3 11.8 40.1 51.3 11,8 _ 40.1 0.0 (gross) 410.6 94.0 320.6 410.6 _ 94.0 320.8 410.6 94.0 __ 320.8 0.0 r(entry) 43.8 0.0 0.0 43.4 _ 0.0 0.0 43.8 0.0 0.0 0.0 r(patio) _ 0.0 0.0 0.0 0.0 0.0 0.0 _ 0.0 0.0 0.0 0.0 ow - _ 34.3 6.8 34.3 34.3 0.0 34.3 34.3 0.0 51.8 0.0 (net) 332.5 87.3 _ 286.3 332.9 94.0 286.5 __ 332.5_ 94.0 269.0 _ 0.0 #312.3 70.5 250.3 312.3 70.5 250.3 312.3_ 70.5 250.3 0.0 Area floor 312.3 70.5 250.3 312.3 _ 70.5 250.3 312.3 70.5 250.3 0.0 Area total (w+r+f) 1035 235 821 1035 235 821 1035 235 821 0 _STANDARD Q value(door) 9 0 0 9 0 0 9 0 0 0 Q value(window) _ 112 11 11 0_ 11 11 0 16 0 Q valueall)(w 17 ___ 5 15 _ 17 5_ 15 __17 5 14 0 Q value(roof) 8 2 7 8 2 7 -8 2 _ 7 0 -- _ ..- --- _ Q value(f -loor) 16-- 4 13 _ 16 4 13 _ 4 13 0 _ _ 16 _ Q value(room) ! 45 8 32 45 7 32 45 7 37 0 ITT Transmission_ _ 4804 948 3520 4799 812 3521 480- 812 3873 0 - - Infiltration __ _ _ _ 3573 807 2864 3573 807 2863 _3573 807 2863 _ 0 Total loss _8.377 1754 6384 8371 1618 6384 8376 1618 6737 0 CFM required 157 33 119 156 30 119 157 30 126 0 Wattage required 2453 514 1869 2451 474 1869 2453 474 1973 0 Electric BB(feet)_ 11 3 9 11 ! 3- - 3 �-� 1 Hydronic BB (feet) - _ 16. .� 4 F-12 16 [ 3 12 16 j 3 13_� 1 -- -- --- - #of hvac registers 2 1 2 2 1 2 2 1 2 0 - ----- - - HYD CHECK 18 4 15 18 4 15 18 - 4 15 0 ELECT. CHECK - 12 3 10 12 3 10 12 3 10 0 - -- _ ..--- -. --- - -- - -- - HYD AVE. 17 4 14 17 4- 14 - 17 4 14 0 ELECT.AVE. -12 3 9 12 3 9 12 3 10 0 REScheck Package Generator Compliance Report REScheck Package Oeneialo, Location: Suffolk, New York Construction Type: Single Family Heating Type: Electric Code: New York State Energy Conservation Code HDD: 5750 Builder Name: The Builder Inc. (Job#F3169) Date: 6-17-03 Builder Address: 20 Fiddler Crab Trail, Westhampton, N.Y. 11977 Building Address: Main Road, greenport, N.Y. 11944 Submitted By: Phone Number: PROPOSED t• Glazing Area 100 X 74.38 - 824 = 9.03% 15.0% Glazing Area Gross Wall Area Proposed Glazing Area Maximum Glazing Area R-Value Description Comments Proposed R-Value Minimum R-Value Ceiling R-38.0 R-38.0 Wall Cavity R-19.0 R-19.0 Wall Continuous R-7.0 R-7.0 Floor R-30.0 R-30.0 Basement R-19.0 R-19.0 U-Factor Description Comments Proposed U-Factor Maximum U-Factor Window U-0.31 U-0.31 Door Front door exempt U-0.35 U-0.35 Statement of Compliance:The proposed building design represented in these documents is consistent with the building plans, specifications,and other calculations submitted with the permit application. The proposed building has been designed to meet the requirements of the New York State Energy Conservation Code. Builder/Designer Company Name Date 1 REScheck Inspection Checklist New York State Energy Conservation Construction Code Air Leakage: [] Joints,penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5'clearance from combustible materials. If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [] Required on the warm-in-winter side of all non-vented framed ceilings,walls, and floors. Materials Identification: [] Materials and equipment must be installed in accordance with the manufacturers installation instructions. [] Materials and equipment must be identified so that compliance can be determined. [] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. f] Insulation R-values and glazing U-tactors must be clearly marked on the building plans or specifications. Duct Insulation: [] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [] Return ducts in unconditioned attics or outside the building must be insulated to R-4. [] Supply ducts in unconditioned spaces must be insulated to R-8. [] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [] All joints, seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [] Cooling ducts with exterior insulation must be covered with a vapor retarder. [] Air filters are required in the return air system. [] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [] Separate electric meters are required for each dwelling unit. Fireplaces: [] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: [] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. 2 [] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the healing energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. 3 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Cirulating Mains and Runouts Temperature(F) Uo to 1„ Up to 1.25' 1.5"to 2.0" Over " 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes. Hot Water Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Ran e F 2'Runouts 1"and Less 1.25"to 2' 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 4 REScheck Inspection Checklist New York State Energy Conservation Construction Code Air Leakage: f] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. (] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5'clearance from combustible materials. If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder. [] Required on the warm-in-winter side of all non-vented framed ceilings,walls, and floors. Materials Identification: [] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [] Materials and equipment must be identified so that compliance can be determined. [] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [] Return ducts in unconditioned attics or outside the building must be insulated to R-4. [] Supply ducts in unconditioned spaces must be insulated to R-8. (] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [] All joints, seams,and connections must be securely fastened with welds,gaskets, mastics(adhesives), mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [] Cooling ducts with exterior insulation must be covered with a vapor retarder. [] Air filters are required in the return air system. [] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [] Separate electric meters are required for each dwelling unit. Fireplaces: [] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: [] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. 2 [] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. 3 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Healed Water Non-Circulatina Runouts Cirulatina Mains and Runouts Temperature fF) UD to V Up to 1.5"to 2.0" Over 7 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes. Hot Water Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F Runouts V and Less 1.25"to 2" 2.5"to 4" Heating Systems Low PressurefTemperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 15 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 10 and Brine Below 40 1.0 1.0 15 1.5 4 0. s Mr. Tom Stephenson January 17, 2003 Page 2 Supplemental Conditions of Approval In addition,the conditions under which system approval is granted are: 1.The manufacturer is to submit to the Division a duplicate of the permit set for each dwelling to be installed in New York State. Each permit set is to be sealed and signed by an architect or engineer registered in New York State and is to bear that architect or engineer's certification that"the plans and specifications of the permit set are derived from and consistent with the plans and specifications associated with this approval on file with the Division and this conditional approval letter."The certifying architect or engineer may not be affiliated or associated with the manufacturer's quality assurance agency. The following are specific requirements regarding the contents of the permit set. 1.1. A set of drawings comprising at a minimum_ 1.1.1 Cover sheet which contains information on: -Project location -Design criteria: listing of applicable design loads such as Ground Snow Load, Seismic Design Category, Wind Speed, Live Loads, Dead Loads,etc. - Applicable building codes and design specifications - Energy code information: statement by professional of compliance with Energy Conservation Construction Code of New York State, 2002 Edition. Method of compliance and pertinent documentation shall be provided. -Occupancy classification - Construction type classification -General notes -Index of drawings - Manufacturer's title block -Certification, by design professional, of derivation from approved system set drawings and this conditional approval letter 1.1.2 Elevations 1.1.3 Floor plans which convey the information on: - Required and provided light, ventilation, egress,window and door schedules - Unambiguous identification of structural members - Smoke detectors and GFC Interrupt protection 1.1.4 Foundation plan 1.1.5 Building cross section with information on: - Building integration (module connections)details - Location of required fire stopping -Roof truss bracing and structural connections 1.1.6 Roof system -Special requirements addressed(such as sliding,drifting or unbalanced snow load conditions) 1.1.7 Non-typical details (such as prow roof, cantilever beams, etc.) 1.2 Summary of references to system for selection of structural members. 1.3 Each page of drawings and calculations should be signed, sealed, and dated by New York State registered design professional. 2. The manufacturer will submit a weekly report summarizing (listing) all permit sets with information about project location, production serial number, and NYS insignia number. 3.The manufacturer will promptly address the deficiencies of submittals. i Mr. Tom Stephenson January 17, 2003 Page 3 4.The system conditional approval is subject to termination upon evaluation of compliance with the provisions of the Uniform Code. 5. The Division will conduct quality control review of permit set submittals to evaluate compliance with the above conditions and with the provisions of the Residential Code of New York State. Deficiencies will be reported to Manufacturer name and are to be promptly addressed. The approval is indicated by the New York State Department of State"Stamp of Approval"placed on the accompanying set of plans.The reconciliation of fees associated with this approval is provided as an attachment to this letter. A copy of this letter,without attachment,shall accompany each set of plans submitted for a building permit and be deemed a duplicate original. Sincerely, George E. Clark,Jr. Director Division of Code Enforcement and Administration Enclosure cc: Kevin White, TRA & Associates,Inc. File 02-062CAL.wpd HEAT LOSS CALCULATION Serial number 3168 Model: DUPLEX Length: 60 Total BTUH loss= 21113.66 State: NY Width: 26 of glazing= 6.1 Date: 6-13-03 Rev: 3168-B R-value Interior 70 deg F Floor: 19 Exterior -8 deg F Wall:j 19 Temperature Diff. 78 deg F Roof: 38 Crawl space -8 deg F Clg4Ht.: 8 Temperature Diff. 78 deg F #o 1 Note:temperatures are based on dry bulb reading U door(entry) 0.21 Electric BB watts/ft= 225 U door(patio) 10.34 Hydronic BB btuh/ft= 530 U window 1 10.31 U wall 1 0.052 U roof 0.026 Electric toe kick heater= 1500 watts U floor 0.052 Hydronic toe kick heater=3300 btuh br great kit bath n/a n/a n/a n/a n/a n/a Lin.ft.ext.wall _ 50.3 31.2 28.8 5.8 0.0 0.0 0.0 0.0 _ 0.0 0.0 Area wall (gross) 402.7 249.4 230.0 46.6 0.0 0.0 0.0 0.0 0.0 0.0 Area door(entry) 0.0 21.9 19.7 0.0 0.0 0.0 0.0 0.0 0.0 0,0 Area door(patio) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Area window 69.1 34.3 7.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Area wall(net) 333.6 193.1 202.6 46.6 0.0 0.0 0.0 0.0 0.0 0.0 Area roof 315.0 236.2 204.8 75.8 0.0 0.0 0.0 0.0 0.0 0.0 Area floor 315.0 236.2 204.8 75.8 0.0 0.0 0.0 0.0 0.0 0.0 Area total (w+r+f) 1033 722 640 198 0 0 0 0 0 0 I STANDARD Q value(door) 0 5 4 0 0 0 0 0 0 0 Q value (window) _ 21 11 2 0 0 0 0 0 0 0 Q value(wall) 17 ___ 10 11_ 2 0 0 0 0 0 _ _ 0 Q value(roof) 8 6 5 2 0 0 0 _ 0 0 0 Q value(floor) 16 12 11 4 0 0 0 0 0 _ 0 Q value(room) 47 32 22 4 0 0 0 0 0 0 MINOa P - Transmission _ 4949 3415 2583 652 0 0 0 0 0 0 Infiltration 3604 2702 2342 867 0 0 0 0 0 0 -- - _- - Totalloss 8552 6117 4925 1519 0 0 0 0 o 0 CFM required 160 114 92 28 0 0 0 0 0 0 Wattage required 2504_ 1791 1442 445 0 0 0 0 0 0 Electric BB (feet) _--- --11 8 7-- 2 _[� 1 r� 1 1 ] 1 Hydronic BB(feet)_.I _ _qi_16 12 -10 3 L_1 1 1 1 �� 1 #of hvac registers I 2 2 1 0 0 0 0 0 0 -- -- ------ HYD CHECK 19 14 12 4 0 0 0 0 0 0 ELECT CHECK 13 9 8 3 0 0 0 0 0 0 HYD AVE. 17 13 11 4 0 0 - 0 0 0 0 ELECT. AVE. 12 3 0 0 0 0 0 0 REScheck Package Generator Compliance Report REScheck. Pxkage Generator Location: Suffolk, New York Construction Type: Single Family Heating Type: Electric Code: New York State Energy Conservation Code HDD: 5750 Builder Name: The Builder Inc. (Job#F3168) Date: 6-17-03 Builder Address: 20 Fiddler Crab Trail, Westhampton, N.Y. 11977 Building Address: Main Road, greenport, N.Y. 11944 Submitted By: Phone Number: ' � • • 0 Glazing Area 100 X 109.26 - 896 = 12.19% 15.0% Glazing Area Gross Wall Area Proposed Glazing Area Maximum Glazing Area R-Value Description Comments Proposed R-Value Minimum R-Value Ceiling R-38.0 R-38.0 Wall Cavity R-19.0 R-19.0 Wall Continuous R-7.0 R-7.0 Floor R-30.0 R-30.0 Basement R-19.0 R-19.0 U-Factor Description Comments Proposed U-Factor Maximum U-Factor Window U-0.31 U-0.31 Door Front door exempt U-0.35 U-0.35 Statement of Compliance:The proposed building design represented in these documents is consistent with the building plans, specifications,and other calculations submitted with the permit application. The proposed building has been designed to meet the requirements of the New York State Energy Conservation Code. Builder/Designer Company Name Date 1 y a STATE OF NEW YORK DEPARTMENT OF STATE 41 STATE STREET ALBANY, NY 1 2231-0001 GEORGE E. PATAKI RANDY A. DANIELS GOVERNOR January 17,2003 SECRETARY OF STATE Mr. Tom Stephenson Sun Building Systems, Inc. 9 Stauffer Industrial Park Taylor, PA 18517 ITIA FACSIMILE TRANSMITTAL RE: M 0052-02-062 System approval- CONDITIONAL Dear Mr. Stephenson: Issued herewith, in response to your October 15,2002 application for approval of Detached One- and-Two-Family Dwellings,and Multiple Single-Family Dwellings (Townhouses) System of Models is Factory Manufactured Building Approval designated M0052-02-062,as authorized under Part 1281 of the Uniform Fire Prevention and Building Code. Buildings manufactured under this approval are limited to installation on sites meeting the following criteria: 1. The Seismic Design Category as determined by geographic location and soil Site Class is limited as follows: Ia. Seismic Design Category A, B, or C for Detached One-and Two-Family Dwellings. Ib. Seismic Design Category A or B for Multiple Single-Family Dwellings (Townhouses). 2. The basic wind speed of a locality is no more than 120 mph. The project site is limited to Exposure Category A,B,or C within the design wind speed. Exterior windows and doors shall be designed to resist the design wind loads specified in Table R301.2(2)adjusted for height and exposure per Table R301.2(3). Provisions regarding Wind - Borne Debris Regions will be completed on-site by others and is subject to the approval of the local code enforcement official. 3. The ground snow load is not in excess of 85 psf. 4. The discrete models derived from system are restricted to non-electric heating systems only. as determined in the Residential Code of New York State (RCNYS) and/or Building Code ofNew York State, an inclusive volume of the Uniform Fire Prevention and Building Code (Uniform Code) incorporated wholly by reference. WWW LOS.STATE.NY US a E-MAIL. INFO(0)DOS STATENY.U5 M-1802 BUILDING DEPT. FOUNINSPECTION [ DATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE CHIMNEY REMAR C-� DATE v % CTOR M-1802 BUILDING DEPT. INSPECTION [ ] OUNDATION IST [ ] ROUGH PLBG. [ FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FI W=" CHIMNEY REMARK OIL- DATE 4/03 INSPECT 765-1802 BUILDING DEPT. INSPECT [ ] FOUNDATION IST [ ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: l DATE INSPECT 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] 1 LATION [ ] FRAMING j FINAL [ ] FIREPLAC CHIMNEY REMARKS: ' DA E /4 INSPECTOR GUS U�/G FIELD INSPECTION REPORT uxiToCONINffiVTS e r � FOUNDATION(IS-61 43 -------------------- -- -- — 15 nC FOUNDATION(2ND) z _ c del ROUGH FRA ZING& PLUMBING Vl r S INSULATION PER N.Y. y STATE ENERGY CODE car FINAL w Oh GAG �d ADDITIONAL COMMENTS O 2. m m r r y 4 a z � d TOWN OF y OUTHOLD BUILDING PERMIT APPLICATION CHECKLIS I BUILDING DEPARTMENT Do you have or need the fol'owing,before applying? TOWN-HALL- Board of Health SOUTHOLD, NY 11971 3 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502Survey www. nortbfork.net/Southold/ PERMIT NO. 151 Check Septic Form N.Y,S.D.E C. Trustees Examined 0I2 .20 Contact: M/&9eG4e: -G�--� Approved_ _ (pl,q 20_S__ Mail to: Disapproved a/c T" Phone: �)[/1 .3 '44 5-qD_.— Expiration Z ,20A / Building or n APPLICATION FOR BUILDING PERMIT �tit� tl Date Wd 200 t t INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. E Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. LeIj Il.. a r� (Signature of pplicant o name, if a corporation) 1917 50aAh�jld W 11971 (Mailing address of appHc t) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder h6��- Name of owner of premises])ar—TWD30 (24OYE OIJnERGJ, xiio—, . (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of cUporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which roposed work will be done: 1060 9 T 64EEUPDV" House Number Street Hamlet County Tax Map No. 1000 Section__ '[�p Block Lot �1 Subdivision / Filed Map No. Lot (Name) � PCf�Gr � GUt�f}'1 I St�J Poo/z- 7D r-1'(rE 2. State existing use and occupancy of premises and intended use and occupancy of propo es d ronstmction: a. Existing use and occupancy 101 -NF W1 7--c, ejwljllT- kV/i`1Z7_ �iUyf-6E 9t91j9KA b. Intended use and occupancy Wil A-PAR AArx)T 1je/1 i O NAM� 03 Dt57",PU770AJ ' 3. Nature of work (check which applicable): New Buildings ✓ Addition Alteration Repair Removal Demolition Other Work SNLY? SQ. (Description) 4. Estimated Cost 5�� Fee ��F3lJ1 Lf� M (To be paid on filing this application) 5. If dwelling, number of dwelling units_bNumber of dwelling units on each floor LA.!v6 If garage, number of cars .B' $ ei3[tN 72-73 6. If business, commercial or mixe occuppancy, specify nature and extent of each type of use. L(EAll LN,j5 eUA�,TS 7 2-73 60 F, &O0 A, Cqzo DP_/_17V ax)Ifs �0- 7. Dimensions of existing structures, if any: Fr?4 gyp' Rear _&Qz Depth z 30 Height /5 ' Number of Stories Dimensions of aame structure with alterations or additions: Front gni Rear 6cp' Dep l Height I FSS Numb r of Stories loD'� (0'� AZ , /S7tWq 02 vN'ITS 72.,x.73 J 8. Dimensions of entire new construction: Front r 20/ Rear ' Depth{!:PYO z Height W Number of Stories ,-I 11A)/T5 b,(, -T l 9. Size of lot: Front $- r f, /. Depth 10. Date of Purchase (Q Name of Former Owner HX CDU 4f�U��1 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES_NO ✓ 13. Will lot be re-graded? YES^NO ✓Will excess fill be removed from premises? YES_NO 14. Names of Owner of premises LSO Address 4ho�BhPRhMone No. Q'2/-191 240 Name of Architect . OQ?7H 1/PaV Address Phone No Name of Contractor(2 SQA Address Phone No. G6,IU7-4fC_VkY. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO 1/ * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF S( r 4) i r—A& '0 AEC being duly sworn, deposes and says that (s)he is the applicant (Name of ind'vidu signing contract) above named, (S)He is the GG�� & ontractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this �� Notary Public Signature of A rcant LYNDA M. BOHN NOTARY PUBLIC, State of New York No. 01606020932 Qualified in Suffolk Coun Term Expires March 8, 20 s1P)p so1J MsT.4 Ss;J Is'•v'h' t��-ra/>� ; - x W 4n7� 2 rniir� aw. >e�ta�x ao1+ .>l . .a� 1p'ubrz- PLAT r I�� 9Y�sl� _ ,� r+ t� a,�zolirstiGoF k - - - - ��" s- Nf{(L✓5p TO 7(/e 47F FGMtI Rd07r $ TO 81C TN#rAt 3�i! T1+1Au OF-iv)` (VP ANO NAlt.4-0 �r � AtWJLRE'!!ORfx IFS 4Aro.alp (2) TON Q7MPbaIT7f BkF i v 'To P>oX r 'b 5. IS TH FlAST Frog MPD PIOtlN PAs'§T ' F" `* Y a: CiONTUCTba TP dR !t!T>ST'ONSxffit:E 1�1lf 11T:T -,.-- T -..1 -- 7. SxkWi'$2PI1 QP P.E,l �9R V1,0109PJl Pk TO 'C1M TP 7Q1F6'Y" �I ATC Px�Fu tJttti� A�f CN FJ fL) h) 4 I ^� _ _ q a S. FooTuh Foe sT4 emw- PLA7IT zA To ea 9"x l9"WIDG VV 9? AN LH02 P3M_T-WARfda• NAfr 1-w _vim— I Ib' LQ"6 W/S. (W= AT a oe"af- ( u� _ i I I COMPLY WITH ALL CODES OF { �- P cYc BALM WAN rKIMI r v NEW YORK STATE & TOWN CODES APP D AS NOTED 4�o'I q(c PN r U u D AT to Al wtmrl I � J ^ ST I I I AS REQUIRED AND CONDITIONS OF DATE 23 3 B.P.e,295/61-0 w SOfMDTOWNZBA FEE-_&L2 0° SOMOLOTUMP UpBOARD NOTIFY B DEP�ARTMLENTAT 785.1802 SAM TO 1PM FOR THE SOUTHOLDTOWN TRUS)EES FOLLOWING WSPECTIOW{: N.Y.S.DEC 1. FOUNDATION - TWO REQUIRED _ FOR POURED CONCRETE Gj If 2, ROUGH - FRAMING S PLUMBING dd rr^-11 1 3. INSULATION 4. FINAL - CONSTRUCTION MUST CERTIFICATION OF BE COMPLETE FOR C.O. NAILING b CONNECTIONSALL CONSTRUCTION SHALL MEET THE f I I I j I REQUIRED. REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT PERPONSIBLE FOR DESIGN OR CUPI9TRuCTICN ERRORS _ 40A{Lg6n IY I (- unii r-1 {i. -� N c - p UNDERWRITERS CERTIFICATE 2fgY E it �! I ! _L I — I REQUIRED PLUMBER CERTIFICATION . l R dgCI`� tTd ON LEAD CONTENT BEFORE ALL CONSTRUCTIONS CERTIFICATE OF OCCUPANCY I l-E 1 I MEET THE REQUIREMENTS�L SOLDER USED IN WATER I i ! {I ! ` • I— _ .— V -.- . { CODES OF NEW YORK STA THE SUPPLY SYSTEM CANNOT UI _�. _ .y;i L, — -- —G I }ar a—, • _ ..�� _ __ ! '_� --.--- -- __ ____ EXCEED 2/10 OF 1%LEAD. OCCUPANCY OR FLOODZ01w� / �4 N ' — U2"d HNCfFOtc L sZS b'�c COMPLY WITH CHAPTER 746• USE IS UNLAWFUL FLOB'Q DAMAGE PREVENTION 01{ I SW * -- Fc7dTIN6 24" Nu)OII WITHOUT CERTIFICATE SOUTHOLD TOWN CODE —�vu�17Prnu wA+ L !' u/1o� Lf XISTIN4% I OF OCCUPANCY r ��''}�r1^� �-T�-r�---^Tf {� 4- � �� � -AD '..".ytrL`+'f�t."J' I L:1i I '"- i � � 'r'�L '` ,LJI j_L ! L '.Li. PLUMBING 1 w _ _ L _. l i�C'/t 3�P 5`F 3' ' K4' 3bTI 3'7.'k 3F' 3�•x `],n '5L2' eyi I_ n �•Ir 3�_In Aa WATER LINES NE LLPLUMBIBIWA T N 1 A� � � � _ - -. 3 ._�. 3�-..__ ,-- --`--� � ,�--- I TESTING BEFORE COEED - 134Iz Far 0.1%-rkv C.li.N7IKUttkti I I. I F-�� 1 -to _ D0140ATIOQ FLAI_� ILO* ALLi NOTE: _. TO THE BEST OF HIS/HER KNOWLEDGE, - - • - - BELIEF, AND PROFESSIONAL JUDGMENT: AEPARTM13,4OFSTAT� THE FOLLOWING NOTES APPLY coq ;pIVJ ?Al 1 . THESE PLANS ARE IN COMPLIANCE WITH OUR ALBANK; NV '1E2EMf40 ,* NEW YORK SYSTEMS FOR DETACHED ONE- Stomp of Approval for a System, OMottelorComponerlt AND-TWO-FAMILY DWELLINGS, AND MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES), MrItn),_ra-D(A, x{ui 5fo �y�y 3 THEY ARE DERIVED FROM A CONDITIONAL Application No. Manufacturer's No, 09te Of AW,1 1I APPROVAL OF OUR SYSTEM MODELS NOTICE This approval is appiw,"only to ltwse comp atltsd"1*ci aty APPROVAL DESIGNATION M0052-02-062, lured pulliIIthat Omtahricatildand assembled atlhef toryrnarrli�r� . DATED JANUARY 17, 2003 4" 57': homthe rlts. T NEW YORK STATE THIS 15 A DUPLICATED ORIGINAL STAMP-OF APPROVAL PER (Section 1201.5 (U) FOR STATE USE =Y- 1.MANUFACTURER APPROVAL BUILDERS 1NF0RI IATION: s SiDIP5aAPP EROVAL NAME: THE BUILDER INC. NUMBER M0052-02-062 ADDRESS: 20 FIDDLER GRAB TRAIL THIRD PARTY INSPECTION AGENCY CITY: WESTHAt IPTON TRA INC 10OF BEARDSLEY AVE STATE: NEW YORK PO. BOX 1061 ZIF: 1191 ELT, IN 46515 /'� 3 DRAWINGALUINGINDEX rvJ PAGE TITLE CUSTOMERS INFORMATION: - COVER SHEET NAME; SAETTA eN GENERAL NOTE6 ADDRESS: MAIN ROAD I FOUNDATION PLAN CITY; GREENPORT 'z FIRST FLOOR PLAN _ COUNTY; SUFFOLK 3 FRONT / RIGHT ELEVATION STATE: NEW YORK 3A LEFT 4 REAR SIDE ELEVATION ZIP CODE: 11944 1 4 CRO55 SECTION 5 1 FIRST FLOOR ELECTRICAL PLAN b) USE GROUP DETACHED ONE-AND-TWO-FAMILY DWELLINGS 6 PLUMBING LAYOUT MULTIPLE SINGLE-FAMILY DWELLINGS (TOIMI HOUSES) ec— E —H� c) CONSTRUCTION TYPE ❑ 5A Z 56 SALES,5ER✓CE _ d) DESI(:iN LOADS. I Acir TmIll«u.PMoI.VII Pe ,j --__--_. 1) WIND 120 I'M,P.H. }. I vl5rt us°N n+E LLEB, lV WJU.EUMMAR.cOM DESIGN PRESSURE. t 33.4 - 362 of MILDINCs SY5TEM5 EXPOSURE: C DESICzN CODES T 1 PAGE ENERGY cOMPL ANCE 2) SNOW: 45 psF RESIDENTIAL GODS OF NEW RK STATE CONTENTS' PAGES TRU65 CERTIFICATION 3) FLOOR: 40 psr nve (LIVING AREA) FIRE CODE OF NEl1J YORK ST TE NEW YORK STATE I PAGES COMPLIANCE REPORT PLUM1EsING CODE OF NEUJ YO K STATE 3 PAGES IN5PECION OHECKLIST 30 pDr IIVB (9LEEFNG QREQ) MECHANICAL COPE OF NEW YORK STATE COKER SHEET . 10 per dead load ENEFeGY CONSERVATION CONSTRUCTION UNIT No. DW MAP . SUNS SHEET NO, TOTAL NUMBER OF SHEETS IN COMPLETE SET 9 4) SEISMIC: B CODE OF NEW YORK STATE DA 1999 NATIONAL ELECTRIC CODPATED-30-03 COVER 3168 REV. La' 31 ' SHEET DATE b-13.0! ' SLOP 8Y1 GENERAL NOTES PATE: FOUNDATION PLAN (SHEET_1) 4, ALL BREAKS IN MATING WALL AND OR FLOOR/CEILING 18, PULL CHAIN LIGHT LOCATED IN ATTIC AREA IS 16. WHEN DISHWASHER IS PROVIDED, DRAIN LINE AND P-TRAP 10 AIR GAPS IN PLUMBING SYSTEMS, ANSI A1121.2-1991, ASSEMBLY SHALL BE FIRESTOPPED PER 8602.8 SUPPLIED AND INSTALLED ON SITE BY OTHERS ARE 2" MINMUM AND DISHWASHER SHALL DISCHARGE 1. ME FOUNDATION SHOWN IS NOT PROVIDED BY THROUGH11 CAS WATER HEATERS, VOLUME 1 AUTOMATIC STORAGE TWE DISCHARGE SUN BUILDING SYSTEMS INC. AND MUST BE DESIGNED S. ALL HEAT PRODUCING EQUIPMENT SHALL BE INSTALLED 19. MANUAL DISCONNECT AT EXTERIOR IS ON SITE CHARCE INTO GARBAGE DISPOSAL.AN APPROVED AIR GAP DISHWASHER SHOULD NOT µATH INPUTS OF 75,000 SPUN OR LESS Z21.10.1-1984 WITH ADDENDA ANSI 321.10 to-85, `Z21 10.18-86. BY A REGISTERED PROFESSIONAL ENGINEER REQUIREMENTS PEP MANUFACTURERS INSTALLATION AND PER CHAPTER 14 BY OTHERS. SITE COANCE WITH LOCAL CODE 4FTHERC- AND OF SHE RC-NYS-2002. 20. ff APPLICABLEANUF WHIRLPOOL IS TO I BE WIRED AND 17. SHUTOFFS FOR FIRST FLOOR SUBS/SHOWERS AND SECOND SITE CONDITIONS. PER CHAPTER 4 OF THE RC-NYS-2002 6 ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH CIRCUITED PER MANUFACTURER INSTRUCTIONS. FLOOR BATH GROUPS TO BE SUPPLIED AND INSTALLED 12. GAS WATER HEATERS. VOLUME 3 CIRCULATING TANK, 2. THIS FOUNDATION DRAWING IS NOT A BINDING CHAPTER 7 AND SECTION RJIB OF RC-NYS-2002. 21. BRANCH CIRCUITS ARE IDENTIFIED ACCORDING ON SITE BY OTHERS. INSTANTANEOUS AND LARGE AUTOMATIC STORAGE TWE, DESIGN AND IS PROVIDED ONLY TO SHOW AN TO THE 1996 NATIONAL ELECTRICAL CODE SECTION 18. CUANOUTS ARE INSTALLED PER SECTION 708 OF ME Z21,10.3-1984 EFVA WITH ADDENDA ANSI SHUT-.3A-85. ICES AND ACCEPTABLE MEANS OF SUPPORT AND SPACING OF 110-22 AND WILL NOT NECESSARILY CORRESPOND TO PC-NYS-2002. 1J. RELIEF VALVE AND AUTOMATIC CAS SHUT-OFF DEVICES ANO MAIN GIRDER COLUMNS, ANY ALTERNATE FOUNDATION HEAT PLAN (SHEETS 5 AND 5nT TYPICAL SCHEMATIC SHOWN, HOT WATER SUPPLY SYSTEMS, ANSI Z21.22-86. ACCEPTABLE TO THE LOCAL BUILDING OFFICIAL, 1. HEATING SYSTEM DESIGNED WM AN INSIDE TEMPERATURE 19. ALL MATERIALS ,PLUMBING FIXTURES, AND EQUIPMENT SHALL INCLUDING ANY PROVISIONS FOR BULKHEAD EXITS, OF QO7 AND AN OUTSIDE TEMPERATURE OF -6F 22. ALL RECEPTACLE OUTLETS SERVING KITCHEN COUNTERTOP COMPLY WITH THE PC-NYS-2002 AND RC-NYS-2002 14. WATER HAMMER ARRESTERS. ANSI/ASME A1122B.iM-DL. IS SATISFACTORY. SUN BUILDING SYSTEMS INC. ASSUMES - SHALL BE GR PROTECTED WITH 15 MPH WIND 2U 0. ALL PLUMBING INSTALLED IN PLANT SHALL BE TESTED 15. VACUUM BREAKERS, ANTI-SIPHON PRESSURE TWE, NO RESPONSIBILITY FOR FOUNDATION DESIGN OR M= VIDED PER CHAPTER 23 OF ME RC-NYS-2002 ANSI/ASSE 1020-89 CONSTRUCTION. 23. ON CAPE MODELS A JUNCTION ROY WILL BE PROj 2 FACTORY INSTALLED INSULATION SHALL BE INSTALLED TO TO ACCOMODATE A SERIES WIRED SMOKE DETECTOR IFj 16 SEAMLESS COPPER PIPE, STANDARD SIZES. ASTM 842-93. 3, DEIGNED WTH A 45 PSF SNOW LOAD MIN. UP TO COMPLY WTH ECCC-NYS-2002. AT TOP OF STAIRS BROODED ON SITE BY OMERS, 21. IN PLANT FIXTURE DRAINS AND ALL OPEN PIPE SHALL BE S [R 85 PSF WHERE APPLICABLE. 24 RANGE HOOD AND DRYER EXHAUST TERMINATION SHALL BE PROTECTED OR CAPPED AND LIBELED FOR TRANSPORT. O. SEAMLESS COPPER WATERNBE, ASTM 888-93. 3. THERMOSTATS ARE ADJUSTABLE FROM 457 TO BBF 4. A 3ILATIO MIN. CRAWL SPACE ACCESS OPENING PER M306.a PER MANUFACNPER'S SPECIFICATIONS. 22. PLASTIC PIPING SHALL BE PROTECTED WITH 1/I6 INCH 18, THREADLESS COPPER PIPE, ASTM 8302-92. VENTILATION OF CRAWL SPACE IS ON SITE BY BUILDER FOR HEATING AND 457 TO 857 FOR HEATING AND PER R408 & LOCAL CODE (RC-NYS-2002 & MC-NYS-2002) COOLING - 25 ALL ELECTRICAL BO%EE WHIN A FIRE SEPERATION WALL (IS GAUGE) STEEL PLATE 2IN PIPE PASSES E OF WOOD S 1V 4, INSTALLATION OF GAS VENTS SHALL BE INSTALLED PER SHALL COMPLY WTH SECTION R321,3 (RATED PENETRATION MEMBER$ LESS MAN 1 1/2 INCHES FROM ECCE OF MEMBER AND 19 SOLDER METAL, ASTM 832-93. ST U o 5 SUPPORTS (PIERS OR COLUMNS) SHALL BE LOCATED AT OF THE RO-NY$-2002). EXTENDED A MIN, OF 2" ABOVE AND OR BELOW PULES PER MARRIAGE WALL PER SPACING ON SHEET 4K MANUFACTURER'S INSTRUCTIONS AND PER CHAPTER 5 W P260321 OF ME RC-NYS-2002 20. PVC DI]83-91. FC-NYS-2002, 26. PANEL BOXES SHALL BE LOCATED ON INTERIOR FOUNDATION q3. JOIST NOTCHES SHALL NOT EXCEED 1/6 OF JOIST DEPTH AND )) Q 5, FIREPLACES SHALL BE INSTALLED IN ACCORDANCE WIN WALL IF CRAIVSPACE 3PTION IS USED. PANEL BOXES SHALL NOT OCCUR IN MIDDLE 1/3 OF ME SPAN HOLES SHALL Y C OOR PLAN (S+ FTS 2 AND 2a1 HEIR LISTING, MANUFACTURER'S INSTRUCTIONS AND SHALL BE LOCATED IN AN EXTERIOR WALL WTH NOT EXCEED 1/3 OF DEPTH OF MEMBER AND MUST OCCUR A ADDITIONAL DOOR & WNDOW SCHEDUIE NOTESFl PER CHAPTER 10 OF ME•RC-NYS-2002, CHAPTER 5 OF THE ACCESSIBWTY IN ACCORDANCE WITH ME 1993 N.E,C. MINIMUM OF 2" FROM EITHER EDGE PER 8502.8 OF ME 1, WINDOW AREA OF HABITABLE SPACE (UMNG, DINING, J. SWINGING DOORS MEET 09 CFM/SF MAXIMUM S FC-NYS-2002, AND ECCC-NYS-2002 27. COPPER CONDUCTORS SHALL BE USED FOR ALL ELEC%TRIC RC-NYS-2002. INCLUDING KITCHEN DINING IF NO OMER DINING & !A INFILTRATION O 25 MPH WIND (1.587 PSF). 6_ COMBUSTION AIR FOR OAS FIRED SPACE HEATING EQUIPMENT WRING. 24 AIR ADMITTANCE VALVES PER SECTION 917 OF THE PC-NYS-2002. SLEEPING SPACE) SHALL BE 8% OF FLOOR AREA FOR 2. WINDOWS MEET 0 37 CFM/LF SASH CRACK SHALL COMPLY WITH CHAPTER 3 OF ME FCC-NYS-2002. 26 ALL BRANCH CIRCUITS THAT SUPPLY 125 - VOLT, SINGLE, NATURAL LIGHT WITH 4% OPENING FOR VENTILATION MAXIMUM INFILTRATION O 25 MPH WIND ACTUAL 25. 6' HIGH FIBERGLASS SHOWER & BATH (WTH SHOWER) WALLS OR 6' MINIMUM. IF NOT VENTED MECHANICALLY TO EXTERIOR, INFILTRATION TEST BY PTL - 0,04 7. BOILERS, PUMPS, COMPRESSION TANKS, FURNACES AND FANS PHASE, 15 AND 20-AMPERE OUTLETS INSTALLED IN DWELLING HIGH MOISTURE RESISTANT GYPSUM WALL PROVIDED IN FACTORY FOR BATHROOMS & TOILET ROOMS SHALL HAVE A MINIMUM '0 LIDING DOOR MEET 0 5 CFM/SF MAX. ARE SUPPLIED AND INSTALLED ON SIZE BY OTHERS. THEY UNIT BEDRROMS SHALL BE PROTECTED BY AN ARC-FAULT STE APPUED TILE 6' HIGH MOISTURE RESISTANT GYPSUM WALL OPERABLE AREA OF 1-1/2 SCI. FT.. 3 $0, FT. FOR J. S _ INFILTRATION ONO E MPH WIND 11.587 PSF). SHOULD BE 51ZED IN CONJUNCTION WITH ME STUN LOSS CIRCUIT INTERRUPTER LISTED M PROVIDE PROTECTION PROVIDED IN FACTORY. KITCHENETTES & KITCHENS (60 SO, FT, OR MORE) SHALL (TEMPERED GLASS) FOR THE HOUSE AND INSTALLED BY QUALIFIED PERSONS, OF ME ENTIRE BRANCH CIRCUIT. HAVE 4% OF FLOOR AREA OPENING FOR MINIMUM YYY»> W • 4. DESIGNED WITH A 45 PSF SNOW LOAD MIN. UP i0 B. ME CHIMNEY IS SUPPLIED AND INSTALLED ON SITE BY 29, CARBON MONOXIDE DETECTOR SHALL BE INSTALLED ON LOWEST 26. HORIZONTAL BRANCH VENT PIPING SHALL BE INSTALLED NOT LESS VENTALATION OTHERS, UNLESS OMERWISE SPECIFIED NO PROVISIONS LEVEL CONTAINING BEDROOMS AND IN ACCORDANCE TO ME THAN 6" ABOVE THE FLOOD LEVEL RIM OF ME HIGHEST FIXTURE IN p B5 PSF WHERE APPLICABLE. ARE MADE FOR ITS LOCATION (I E. FRAMED OPENINGS) MANUFACTURER'S INSTRUCTIONS IT SHALL BE LOCATED IN SERVED IN THAT BRANCH, 2. HABITABLE KITCHEN & SLEEPING) &N REO CITATION SPDAICE SHIT ALLCHAVE ` 5. ALL WNDOWS MEET OR EXCEED UNLESS SPECIFIED BY BUILDER PRIOR TO MANUFACTURING THE GENERAL AREA Of THE BEDROOM(S) AND WALL IN ADDITION TO PRIMARY EXIT AN EMERGENCY USE REQUIREMENTS FOR LIGHT, VENT AND 9. ANY HEATING PIPES OR DUCTS IN UNHEATED SPACES SHALL MOUNTED 8' A.F.F. OPENING TO LEGAL OPEN SPACE OF 4 S0, FT. MIN. WITH EMERGENCY EGRESS PER SECTIONS R303 & R310 BE INSULATED IN ACCORDANCE WITH MC-NYS-2002 ANO FIAVORMENTAL CONSEBYA119N A MIN, DIMENSION OF 18" & A MAX. SILL HEIGHT OF S-6" (� ECCC-NYS-2002 (42'), BASEMENT OR CELLAR 4'-8" (54") MAX. d5 ~ 6, STATE SEAL INSIGNIA SHALL BE LOCATED IN •HN, • TRIC (SHEET 71 27. BATHTUBS INCLUDING GARDEN, WHIRLPOOL & HOT TUBS ppT KITCHEN SINK BASE CABINET. 10, SEE TABLE 5-3 FOR AFW FOR HEATING EQUIPMENT - SHALL HAVE AN OVERFLOW 1 1/2" MIN. 3 SPACES MEETING MIN HABITABLE SPACE REOUIgMENTS d O TBT AND SEER FOR AIR CONDITIONING EQUIPMENT THAT IS TO 1 EACH DWELLING UNIT 'SHALL HAVE ONE MAIN 3" MIN.. (60 SO. FT & 7FT. 6 IN HIGH) SHALL COMPLY WM o 7, ALL DRAWINGS MEET REQUIREMENTS CONTAINED IN BE FIELD INSTALLED BY OTHERS, L CODES OF NEW YORK. BAN. STACK FROM BU MIND GRAIN TO 6' ABOVE POeOF. 26. WATER CLOSETS 1.6 CAL/FLUSH MAX. HABITABLE SPACE REQUIREMENTS EG. LIGHT, VENT & ME RESOENTIA 8. IF APPLICABLE L LEVEL PACKAGE SHALL INCLUDE PER SECTION 9041 OF THE PC-NYS-2002 SHOWERS - 2.5 gpm MAX. O 80 PSI: KITCHEN SINKS AND EGRESS I' 2 ALL PLUMBING TO BE IN ACCORDANCE WM ME LAVS = 2.2 gpm MAX O 60 PSL STAIRS, LANDING AND RAILS AND WILL BE INSTALLED Fl FCHICAL NOTES (SHEET 6 AND 601 4. GLAZING IN INTERIOR & EXTERIOR DOORS, FI%EO SIDE OI 3 ON SITE BY OTHERS PC-NYS-2002 29 ANTI-SCALD MAINE VALVE MANUFACTURER INTO /623]0. PANELS, NBT SHOWER ENCLOSURES (INCLUDING DOORS. U3 1 ENTRANCE PANEL CUTLER-HAMMER BR2040B200PK, OR EQUAL, 3 ALL WATER SUPPLY PIPING AND 9) SURE RISERS UX SH BE SHALL BE INSTALLED / ME WATER SUPPLY TO ALL PANELS & EXTERIOR WINDOWS), INTERIOR PARTITIONS 18" 9 ALL DWELLINGS UNITS WHIN FIRE LIMITS SHALL 20 (FULL) BREAKER SPACES, 40 (HALF), 200 AMP CAPACITY. TypE 'L' COPPER (ASTM B BB-99) SOLDER & RU% (SHALL SHOWER AND SHOWER/BATHING Fl%TURES. OR LE55 FROM FLOOR LEVEL SHALL BE SAFETY GLAZING COMPLY TO SECTION R302 & R321 2, CONVENIENCE AND APPLIANCE RECEPTS PER 1993 NEC MEET SECTION 605.15,4 (SOLDERED JOINTS) OF ME PC-NYS-2002. 30. PLASTIC PIPING SUPPORTS - h'G O OC. FOR PIPING 5, EACH DWELLING SHALL HAVE AT THE PRIMARY LOCATION A 10, KITCHEN AREAS ARE TO BE MECHANICALLY VENTED 3. SWITCHES AND COUNTERTOP RECEPTS PER 1993 NEC U DIAMETER AND LARGER; 3'-O" OC MAX FOR PIPING MAIN ENTRANCE DOOR. MIS DOOR SHALL BE BOM SWING 4. STANDARD024DRAIN LINES SHALL BE PVC SCHEDULE 40 UNDER H DIAMETER. MAXIMUM VERTICAL SPACING EACH TYPE & 36" MIN WOE. 4 AT H/ CFM (NON-VENTED PER MECHA I TRANSFER AIR) 4 OUTDOOR LIGHTS 70" ABOVE FINISH FLOOR. ASTM 02466-99 (RI982). STORY HEIGHT AND PIPING SHALL HAVE AMID-STORY � M BATH/TOILET AREAS ARE TO BE MECHANICALLY VENTED GUIDE (PER P2605.1 OF ME RC-NYS-2002). PL c9 "d AT 50 CFM PER MC403.3. 5 ALL MODULAR CROSS-OVER CIRCUITS PERTAINING 5. CONCEALED PIPING IN UNHEATED AREAS INCLUDING OUTSIDE WALLS ADDITIONAL NOTES 11 ALL GLAZING TO COMPLY WTH R308 & ME ECCC-NYS-2002, TO CONVENIENCE AND HEAT CIRCUITS SHALL TERM- SHALL BE PROTECTED AGAINST FREEZING IN PLANT PIPING SHALL 31 ALL HORIZONTAL DRAINAGE RUNS SHALL HAVE A SLOPE OF INAIE IN JUNCTION BOXES OR ML APPROVED 1 4" PER FOOT TOWARD DRAIN FOR 2' AND SMALLER 1. ALL MATERIALS, ASSEMBLIES, CONSTRUCTION AND ,�R.45a5 BE KEPT OUT OF UNHEATED AREAS WHERE POSSIBLE. // ADGENEQUIPMENT SHALL CONFORM N RD REGULATIONS & 12. APPROVAL OF PLANS FOR SECOND FLOOR USEABLE SPACE AMP CONNECTORS (P SHALL HAVE A SLOPE - 002) PER FOOT TOWARD GRAIN IN ME CAPE COO, FOUNDATIONS, INSULATION INSTALLED ON 6 SMOKE DETECTORS WILL NOT BE PLACED ON ANY 6. BASEMENT MODELS SHALL S PROVIDED IN FACTORY (DER TABLE 7041 PC-NYS-2002). AND GENERAL ACCEPTED STANpAR05 OF THE NEW TOftN SITE, EXTERIOR AND BASEMENT STAIRS, SITE INSPECTIONS SWITCHED BRANCH OF A CIRCUIT OR ANY C F.1 AIM A Z INCH VENT 10 BASEMENT STUBBED BELOW RC PC MC ECCC BG FC t g OF THEIR CONSTRUCTION AND ME INSTALLATION OF ME CIRCUIT AND SHALL BE WRED IN SERIES FOR FIRST FLOOR, MEN CAPPED & LABELED. BASEMENT 32, ALL WATER SUPPLY PIPING SHALL BE SUPPORTED 8'-0" O.C' 2, DISCRETE MODELS P b VR HOME SHALL BE UNDER THE JURISDICTION OF ME LOCAL SPONTANEOUS ACTIVATION. VENT MAY BE DELETED WHEN GLOMES WASHER IS MAXIMUM (PER TABLE P2605.1 OF RC-NYS-2002. ( CANS HAVING UR SAME SPECIFIC - 1 BUILDING CODE ENFORCEMENT OFFICER ON FIRST OR SECOND FLOOR 33, HORIZONTAL TO HORIZONTAL & VERTICAL TO HORIZONTAL ROOM ARRANGEMENT OR ARCHITECTURAL STYLE) SHALL DRAIN CHANGES IN DIRECTION SHALL BE 45 DEGREE Y'S BE PREPARED FROM MESE DRAWINGS WITHOUT 7. WHEN B-LEVEL OPTION IS PROVIDED OR WHEN ] FIRE BLOCKING SHALL BE PRONGED PER R602.8 MODIFICATION, ADDITION OR DELETION IN ANY MANNER 13. SKYLIGHTS SHALL C IN COMPLIANCE WM SECTION STAIRS LEAD O A HABITABLE LEVEL A SECOND U L OF RC-NYS-2002 LONG SWEEP 90 ELBOWS, LONG SWEEP TI'S 6TH, BM OR 47 BUIL I & THE 58 SHALL APPROVED SHONE DETECTOR WLL BE SITE INSTALLED ISM BENDS, APPROVED COMBINATIONS OF MESE OR 3 ANEW YORK LICENSED ARCHITECT OR PROFESSIONAL F 14 BUILDING TYPE 5B SHALL NOT EXCEED A HEIGHT OF AT HEAD OF STAIRS. 6. MAXIMUM DISTANCE FROM FIXTURE VENT TO TRAP IS EQUIVALENT LONG SWEEP FITTINGS (PER TABLE 706 3 OF ENGINEER MAY MAKE THE DETERMINATION THAT A MODEL N THREE STORIES 8 VOLTAGE DROP DOES NOT EXCEED 3% IN FEEDER OR 5'-0" FOR 1 I/2" MAP & DRAIN, & D FOR 1 I/2" MAP ME PC-NYS-2002). CONTAINS ANY PARTS, COMPONENTS, OR ASSEMBLIES N BRANCH CIRCUITS OR 5% IN BOTH & 2" GRAIN, & BOOT FOR ) MAP & DRAIN (ALL ARE TO WM IN THIS SYSTEM PACKAGE. 15, EVERY DWELLING UNIT SHALL HAVE AT LEAST ONE HAVE & D PER FOOT PITCH). MAXIMUM DISTANCE FOR 3" 34 ALL DRAINAGE CHANCES FROM HORIZONTAL TO VERTICAL HABITABLE ROOM THAT HAS NOT LESS MAN 120 SO FT 9, SMOKE DETECTORS ARE REQUIRED IN EACH BEDROOM MAP & DRAIN I$ 10'-0" WM AN 1/8" PER FOOT PITCH, SHALL S THROUGH A SANITARY TEE OR WHEN (2) 4. ONE AND TWO FAMILY DWELLINGS ARE EXEMPT WHEN `^ (PER R3041T AND A MINIMUM HORIZONTAL DIMENSION OF PER STATE CODE. FIXTURES ENTER A VERTICAL STACK AT THE SAME LOCATED IN SEISMIC CATEGORIES AN FORE CATEGORY 7'-0 IN ANY DIRECTION (PER R304,3). IT SHOULD ALSO 9. MAXIMUM DEVELOPED LENGTH OF FIXTURE MAP LEVEL, AN APPROVED DOUBLE FIXTURE FITTING SHALL ME HEIGHT IS LIMITED TO LESS MAN THREE STORIES S HAVE A MINIMUM CEILING HEIGHT OF 7'-6" lPER R305) 10, ALL ELECTRICAL CONDUCTORS AND EQUIPMENT SHALL TO INDIVIDUAL VENT, WET VENT OR STACK VENT BE USED. ABOVE GRADE AND MERE ARE NO IRREGULAR PORTIONS 61 EXCEPT IN HALLWAYS, CORRIDORS. BATH/TOIILET ROANS, BE LISTED OR LABELED BY A NATIONALLY RECOGNIZED SHALL BE 1 1/2"=3'-6", 2"=5'-0" & 3'-6'-0" BRANCH HORIZONTAL TO VERTICAL CHANGES IN IN ME STUCNRE AS DEFINED IN 8301.22.7 AND LAUNDRY AREAS WHICH SHOULD HAVE A MINIMUM TE%TING LABORATORY, IN COMBINATION WITH PER TABLE (III-903) DIRECTION & ON 3 INCH OR LARGER CEILING HEIGHT OF Y-O". LISTING AND LABELING, CONDUCTORS AND EQUIPMENT 10, JOINTS AROUND PLUM3ING FIXTURES SHALL BE MADE SHALL BE SUITABLE FOR BOTH ME LOCATION AND USE. WATERPROOF AT FLOORS, WALLS & COUNTERS, TOILET NOTE_ TANK EXCLUDED FIFVATIGN (SHEETS 3 3c. 35 AND 3c) 11. CONNECTED LOAD OF ANY ELECMIC BASEBOARD TNUMBING R.� NCf STANDARDS SUN BUILDING SYSTEMS INC. CERTIFIES THAT; U= HEATER BRANCH CIRCUITS SHALL NOT EXCEED SOX IT. FEW INSTALLED: PIPING BETWEEN FIRST & SECOND ELECTRICAL CONDUIT, ELECTRICAL WIRE INSULATION, OF ITS RATING. FLOORS, BATHROOM TILE & FREEZE PROTECTION OF I MTREOUS CHINA PLUMBING FIXTURES. ANSI 112.19.214-1990. A) I. ALL VENTS MRDUGH ROOF TO BE 3" IN Y DIAMETER AND SHALL TERMINATE ABOVE ROOF CRAW. SPACE PIPING. ALL WORK DONE ON SITE PIPE, DUCT AND THERMAL INSULATION USED IN UNITS Z UNE A MINIMUM OF 6" (PER PC9041) 12. ME MAIN SERVICE DISCONNECT SHALL BE AND ALL INTERIOR WALL AND FLOOR FINISHES 2. pE51CNE0 WM A MINIMUM SNOW LOAD OF 45 PSF ANDA INSTALLED AT A READILY ACCESSIBLE LOCATION SHALL BE APPROVED 3Y ME LOCAL BUILDING CODE 2 STAINLESS STEEL PLUMBING FIXTURES. ANSI 112.19.3-1987 COMPLY TO CHAPTER 7 OF THE RC-NYS-2002. NEAREST TO THE POINT OF ENHANCE OF THE ENFORCEMENT CFFTCEI'. PIPING SHALL BE FIELD (DESIGNED FOR RESIDENTIAL USE) -y f MAXIMUM SNOW LOAD OF 115 PSF MERE APPLICABLE. SERVICE CONNECTORS AS PER NEC SECTION 230-70A. TESTED PER NYS. CODE 907 BEFORE CONCEALMENT. B) A REPORT OF SUCH TEST HAS BEEN FILED H S ME 3. PLASTIC BATHTUB UNITS, ANSI 21241-198] w/.to-90k1b-91. DEPARTMENT OF STATE IN ACCORDANCE WITH SECTION 3 SIDING SHALL RE FIELD INSTALLED ON SITE BY OTHERS T3 ALL ELECTRICAL WORN SHALL BE DONE IN ACCORDANCE 12. WHEN A BOILER I$ INSTALLED. A BACKFLOW INSTAPREVELLED TO PLASS 0 ON GABLE ENDS, AND UPPER MODULES OF TWO STORY WISH THE 1993 NATIONAL ELECTRICAL CODE OR WITH ATMOSPHERIC VENT ON SUPPLY IS INSTALLED 70 4. PLASTIC SHONER RECEPTORS AND SHOWER STALLS, MODELS WTHOUT MODULE OVERHANGS, APPLICABLE STATE ELECTRICAL CODES, FIRST OR SECOND FLOOR BOILER ANSI Z124.2-1890. Cj PLASTICS (INCLUDING GLAZING, SITING & SKYLIGHTS) & FOAM PLASTIC (INCLUDING INSULATION) IF USED SHALL 14. ALL NON-METALLIC WIRES TO BE RATED AT MINIMUM 13 FOR CRAWL SPACE UNITS' SPACE FOR WATER HEATER SHALL O• ROSS SECTION ( H T 4) 90C AS PER 1993 N E.C.. BE PROVIDED IN PLANT ON FlRST OR SECOND FLOOR, 5 HOUSEHOLD DISHWASHERS; AN51/ASSE 1006-89. COMPLY WITH GRAPIER 28 OF ME BC-NYS-2002. 15. A LIOHTINO OUTLET AND RECEPT IN ADDITION TO ANY INSTALLED PER CHAPTER 5 OF ME PC-NYS-2002. µL� Ott\ i, ALL STAIRWAYS, HANDRAILS, AND GUARD ARE W COMLY 6. HOUSEHOLD FOOD WASTE DISPOSER UNITS. AN51/ASSE WITH 8312 THROUGH 8318. REQUIRED OF CIRCUITS FOR LAUNDRY AREA IN TI. ALL WASHERS STANDPIPES SHALL BE INDIVIDUALLY TRAPPED. 1008-66. 5� r4 H' TH STANDPIPE SHALL EXTEND A MIN. OF IB' AND A MAX, OF �`TP H •T,\ BASEMENT SHALL BE PROVIDED ON SITE BY OTHERS. F v� O' m IN OaDNOITrs nE IA'1�n 6 2. DESIGNED WITH A 45 PSF SNOW LOAD MIN. UP TO 42 ABOVE THE MAP ACCESS SHALL BE PROVIDED TO ALL ]. CAST-IRON THREADED DRAINAGE FITTINGS, ANSI B7612- 91 Slx 141 ETWI MTM 149.x0 AND ITT I'TDOEL• 85 PSF WHERE APPLICABLE 16 A DROP T TO BE PROVIDED FROM A FIRST FLOOR STANDPIPES AND DRAINS (PER SECTION 802 4 OF ME n ) FNOEIIEWtt If uAApON N U . R3A� SMOKE DETECTOR TO A SMOKE DETECTOR LOCATED RC-NYS-2002) B. ACRYLONITRILE AND 80.NE-STYRENE (PVC)) PLASTIC M E, .I Au ASTM IR IN CS)AIMILAM Side -J SIdO 3. INSULATION IN FLOOR AREA ABOVE BASEMENT IN BASEMENT. SCHEDULES 40 AND B0. ASITIA 01527-91 (R-1082) c m 0u Im1crLN K DIRpM001 OR IN BASEMENT WALL AREA SHALL BE ON SITE 15. PLASTIC PIPES PENETRATING A FlRE-RATED ASSEMBLY WILL z l\1GIM NAT Ir ISMOT W t LDIm M BY OTHERS AND SHALL COMPLY WTH THE 17. ALL EXTERIOR FIXTURES ARE SUITABLE FOR NET HAVE A RATED FIRE COLLAR INSTALLED PER MANUFACTURING 9. SOLVENT CEMENT FOR PVC PLASTIC PIPE AND FlTTIN _ EIlOty W.M MMD W M O MAg19 NARIS ww"MONCeENlEIMAL NATE! ASTM 02235-81 L / O MXw'mL ON LOCATIONS. SPECIFICATIONS. WIXO U 001T01R Mr NOT K DMIXED M �� ECCC-NYS-2002 of 2',' NNME PI M TWIT M ONDIS A ISTD MMEET, F TNc si Mw(XIT M UNNNY9il1 l0 MIVONS]gl V TM MONO Mme k 9W0(�BYe REFER TO SHEET GN FOR NOTES ppm; PERTAINING TO THIS DRAWING. L DS SHOWN FOR ON SITEIGN PURPOSES ONLY. 0 ZERO LrT LINE • _______________------------------------------------------I__._ --__________________—____—________—_______r I I ____ __________________________________ ___________________________________________ _____________ I � 010 PLF I 038 PLF � I I I I I I jCPt"L SPACE ACCESS 4 VENTILATION DESIGNED 4 LOCATED BY BUILDER PER I = 1 R O m STATE/LOCAL CODE REOUIREi'IENTS. I I 10 QyQ � m I I I — I I I I I I 1 I I I I 4'-1" 4' I" 4'-1 4'-1 I 4. 11. 4' III 4 _61 4. 6.. 41 I❑ 4 _11 4'-1 4'-111 41.111 I _ P r___T ll L _J L J L _J L _J L _J L _J L _J L —J l _J L _J L _J I I I nr 618 PLF 70 PLF I mf I NCPIER I CONCRETE FOOTING Z (TYPICAL) I I � I r REQUIRED SEPARATION BETWEEN (� I I WILDING AS PER GOVERNING I — I CODES IS THE RESPCNSIBILIT7 rtl 1 ? OF THE BUILDER I I I I I I I I 018 PLF FfOUNDATION rfOUNDATM 028 PLF — __ FOOTING WALL IA L_ _______ ____________________ ______________ _J I 60 I II -� .�oocuwllr a,K FtFmrr a $ ' w«w�Mmw wC. Nw aaxrua rlooE� t�w+i uc IN°Wis m�'w'nww�A°r u: Side Side BLDG. #4 1rOpw1A1wlNtpww mo tOmlpropu�w TIT rotor mom oRauiG, GYJ7FA a p�ol w YIg m FOLNDATiON (RANCH DUPLEX) FOUNDATION PLAN M ^�II r IMARTo SWMAN LAYOUT Ipl am N M N11NZ N1w[® ' w�?IiM�MIO LIGHT E Vi"NT CMAW . IW.�IAN• .�. W.Rm wemw3C/®14.E Y IY/IOMf " + .. .• + ao eu NOTE: BYr •AR"R°AEWar I— + TO THE BEST OF HIS/HER KNOWLEDGE, DATE: LEGEND, IXTERIOR DM SQ1F911E BELIEF, AND PROFESSIONAL JUDGMENT THE FOLLOWING NOTES APPLY ♦ Do+°m LrcA.w ru wswAor AYnwa 1. THESE PLANS ARE IN COMPLIANCE NTH OUR r. + ® uA AvrROvm(u-wl wort artcra Ar I l4w.w I NEW YORK SYSTEMS FOR DETACHED ONE- uLA1,I(Ao-w)cAmwYwoN00 AND-TWO-FAMILY DWELLINGS, AND MULTIPLE ® DERaaX MwxooW Arq BlTtltlpi GDOR BCI®ILE SINGLE-FAMILY DWELLINGS (TOWNHOUSES). ® o" A �"'" 'Y . �l THEY ARE DERIVED FROM A CONDITIONAL R+aqAPPROVAL m Y. APPROVAL OF52-02— OUR SYSTEM MODELS, .- wl Tim T DATED JANUARY 17, 2003 Ek u qk dwa..�w,.aw�°..°.r.d. mma ZERO LOT LINE ��".r.�..."°`�..,. raL'R NpR wLL Y lUIT AccamxG ED 1TESE PLANS - ;.r yyy111 I OTE: R-WALL, MAIEWAIL GIM ENO WALLS pF 4 D UUOi ZERO LOT ONE WALLS ARE ILT TO THE STANDARDS OE MEMOO ]NEMOD 5 STATED IN SECOON R602 M.] THE 2000 IA.0 T1ESF METHODS AAE33 3 II ATEGOR.EC' ND FORK OESTOIq� i7aTE00Rr'c' Ax0 vm LxNO svEEDs a 1•644 8'-3 ' q "0 M.P.H. REFER TO SHEET ON - 10.-0" FOR NOTES PERTAININC TWIN-3051 UIS TWIN-3097 TWIN-3051 3/B'FG r"1°E 'omuwi { rs15b TO THIS DRAWING dae I N 6• -92'w X u-ue k d LL RO.FOR A/L WIT 30' -5/e'GL X k•VD'K 15•RL.TTTE RIP.FOR AIL WIT N' L i Rc �E GREAT ROOM LL�RATED waLL � GREAT ROOM � . x oRTmvJ. , 4 n s AAs m i AFEvrecra+ lu R r o Q am dEEL ODk � b'LVL Iffalll�p g ' fll EApI Fldlf L _ Q TM_ _'_�-i fI1 W LVL RWYI� Up/! , (U N'Lvl.FEL2IMED Ed01 NLLF LA_ ___ �� (I)V'-LVL Recllll® CA wLLF Aep.•E }o n > v—s—n 1e RUW CEILTG lG1e11De — _-- —RlyEl`GILNO f3111VD3 f31511De 1LWYI CEILIG (USTWO 31 eTtle — —ALyEN L1;LL1Ati5 -- f51lMO s $ r B k2 Ep �.BbFOLp g , I'F 1951 ROD)5EDFROOMGAdInk 5; -ELECT BEDROOM `+e COL J "� 'FC.TYR 6N 1` 0RYAALL 30" 9C AU ECT 'k 9 Q 0 / ! �• ld c97 w IWyVw eon W BATH LM O KITCHEN rqO O C • DAH G1 O yµ�A0410 YL c10 PANL (7 OUTLETS ` ® 7ED WELL Pte'- (I)OUTLET 16 32' o 0 00]I30 ° D.TIDIlEOE 31' Cal 0 0 ~L EGRESS III NAM ... EGRESS & E1/14 043015 Air DC2A30 11UIN-3057 I I g1E•2 I I q� 24210 13 �TW , IN-3051 �] I I 7MI10 3 4 E j� 44" 4' 5'.p' q " IP-21" 8'-3 3'-y ' RRaksrsimlwm cOtr Ear n' CCC KXvgwcPL pROui"wEwOTua fj� IT 0IRWD MAMlEIIm AND 10NO1 ro mW 0 Cmmm 9REcr 10 TK FIR5T FLOOR PL 4N �MTaqum,� OIII VAI MMIUOS,YI!MR ROH. RIC mum MY mom 0fg101m V-0 CEILING Olp "OIOLE«IN MM M AEIRInDo rRNioui mp�p �WRXTT TI[OOIp>m TIYTIBN TpE{}y 0r RY IIROER!TlIY15"IC gFU LOT LINE 9NOP BYI DATE: 5.0 1 5 FIELD INSTALLED RIDGE VENT I DELETE GABLE END O14. DELETE GABLE END O.N. In 0a Y LL 0 1 f � � EXTERIOR LIGHTS SHIPPED LOOSE FRONT ELEVATION 4 IN STOOPS / HANDRAIL Y FOR ON-SITE INSTALLATION BY SUPPLIED 1 INSTALLED 6Y � 4 zztl q BUILDER BUILDER MODULAR MATCH LINE— IELD INSTALLED RIDGE VENT nm 17 n Z � cf� 9 I � h tk.EO��fil r, Q> �y qt O � ! 1IISCCCd tro� J� THE ST hTF" � J 4 O 9 'M!000�olr u 111E nlvan a � � � iV ]lM ulpiC Srrdi IK Mq Cdrwq MODEL, wmc%u>agnrlq�rua side Side RIC�NT ELEV4TION wm su" 1 m mV w IT a ev K m nE DRN1Mq� maml WIT a wr ro 1c wm a carom a,q um ro xo M IwxE ELE VdTION GABLE END HORIzoNTAL vlNtt REFER TO SHEET GN FOR NOTES nuts e.aan.gmsarurs PERTAINING TO THIS DRAWING. '°10f1"ONa�moeia`aal� �, SIDING SNIPPED LOOSE 1 FIELD ITUM"q N�M INSTALLED BY BUILDER , Or M 14R4S N O fM MONC SRmY9 YG ' I I i I5t10P BY, MLD INSTALLED RIDGE VENT DAIS, DELETE GABLE END O.N.— ----DELETE GABLE END O.H. 4 111j , Q F J 1 'Y � $ 44 00 LL nn m 0 EXTERIOR LIGHTS SHIPPED LOOSERE /` FR L� L V A T I ON STOOPS/STEPS A HANDRAIL p B FOR ON-SITE INSTALLATION BY f R A SUPPLIED A INSTALLED BY • }> BUILDER BUILDER. a MODULAR MATCH LIN 1jrj IELD INSTALLED RIDGE VENT a" w z I � m W N Q LL SEftEG qF; �� i9 � u` ipH N. T•. �� �.� 'Z op T'I E_5 'E. � � N LEFT ELEV,4TION mr �1 � "6I/"wMl ul y AftSide 5J Side rt x nuc nlxrsmm ao rauEo GABLE END HORIZONTAL VINYL m ra N II M 51/Lcr ro� pRAunly, - ---- mann �r rt n nor m w:corm a SIDING SHIPPED L005E i FIELD "'0� "� m 1OMMM°N ELEVATIQN INSTALLED BY BUILDER REFER TO SHEET GN FOR NOTES ouNxos .1NI = nIXUr 11[ M"r"r nor N:W PERTAINING TO THIS DRAWING. ""N"N "rrnrmona wm 6H6ET 3A m mp NMI 11[11"N]E N1plOm ■ l m ONEssm wrRn n[IY9011 V m IlNPIO Mrp15 m 1 JTT �13 REFER TO SHEET GN FOR NOTES ppm: PERTAINING TO THIS DRAWING. RELD WT4LED 6TRAP6 Od WI1.6 OR 1444V1N6 FEERTiAM 04" HELD CONNECTION W STMM J'OG PER Ji m k 110-6"'A"EVER1 Yd NAILS 6.00.DOTH N0E6 Y � OIIID 10 TIRW FASTEN uOrN TIRB6 MAPM b(IOd WILD PER iRL601 RIDGE VERT RDMFLIP611"PLIED 6HIP LOM PIBERGLA63 BHWGLE6 INSTALLATIFOR ON IF 0.1P SAVE Ir MIUDFR ROOF SHEATANfi ALIM.DRP EDW PAPER MAWPACT111E V, ALUM FA6OA TIEIII t Vd D ILO CO6'C'm IW 6LB FA5DA i HELD GRNEOTIM W SSSSllll FERPORATED 6ORT E .7 a~ GCNNE�GIR6 JOd x VA'61RAYED IIIOI DBL.TOP PLA1E k Ik1 LEOfafR STUD TO TRBE I FmIB! app : WW p EVEG'A'CO.S'Wk VI"DRISWL N 16 V R�jOP IRg6AL7URE0 FLUL!Wn-lOd PBi TRtl1 Iw iT1D.li'OG FF zo FIE CONNECTION Y0G R•R wII YCN 4 TAi BEATING r RGID w BDARD O L ROOF RIDGE DETAIL r21 FLIP EAyE DEtAIL s FIELD CON"STA OpFF l%1L'.JO OA PE'BlRRP��OJL T ION a 'DI¢ilEAL1 US)Ib'B W 6TAftE5 TO LOYG - 1'R&D N6 WARD 24 6TN0•Ii'DO, KW P06T By WILOERDEALS, •• FOR TgRION LOADM 4 YNTL 51Dw R•B N6ILATGN eor.ftare �� m IBCAxlml4b 3/A•rKx DEmm R.36 WRLAT PIE RyAFACTWEp I I 611ID TO BANDS I PmiEN MV ROD"1wME f61 i0d PER NDE / FElEAXAS55HNGLES OSS" dE IGd TOE TAILED Q V 04 PeRPETER d FIELD COfECTKN DBL,L PERI BADS O Y dIILDNG PAPER � E Q I� ANCHOR BOLT td CONT."LER 5/E'DRTYWl T PJ,Nu PLATE V13-14NH lDl3-IdNN �oF xEarwNG S p 'i DBL TOP fuTE JR G,x yr 6TRAfm Hi:T+ NON-STORAGE NON-STORAGE �I 'BLoc1c«P831ED iTb ro tRW I rmTN FOAPJAiICN WALL Iu'MID f E'OD. WV b NAILI PER 00 s PRSIAwsAcnrED (4 ROOF�� f C f•1 ON SITE BY OM1ER 1FERq•ftT / _� / d,p y� . 5 EXT. UJALL � MATE WALL TRUSS DETAIL _ EBB!!S FDA. DETAIL -mN61LATION R36PEU4"" b ro'DRYWALL GroDRTWALL 'RIGIO w,BOAFO yy � s 1/16'6V.Ea 7.6 6TID5tIG'61EATNMG P F DRTWALL J x 6 STUD VNT L SI01 'DIiTWALL O N'DRTWALL NTL SOW LWN IR'DRYWALL I.RGID w BO -R N6JLATION v3 5TID6 R-R Nb"Tl Y N4 67W•W'0L N'ftTWOOD TNER'q ftT N TERNO•ftT ftw000 BLOGGNG 4""w DECKING W'T*DIE .(\ O A V/ 3/L'TIG DECKING ATE DBL JxlO PER'v BAID6 1x16 HDDR JOUT6 / 1 x IB FLOOR J016i 1/1'x10'TlEADED ROD ()) yj i10141 L�R61 Wr6 ` ILL PLATE ON R INSAATION IS NMYATION Jx JOIST ATE By OTHERS JOI6T HANGER •P.r.NLL RATE II •dNC41OR BOLT - WFENYYC cm Gm II PER LOCAL CODE qt �:�" '�H w, 'l , p,� + 'MACK FIER m PEAYRtD BY PL Q /,r p xT` I.) ON SITE BY OTHER t0 �//��y \ !!Qm t� MATE/PIER DETAIL - - I - FANENNG OFLCTIRTOPOIe HALE _ x ;� ` &iALL BE W11H LLA RALE•TOE WILED NT 4 � - ' FERRETER eawE AND 6E1 PLA1E.w Uu GRO55 SECTION M660BIpYK NE IRB m A � I m ]IR RAINK 51SIB6 RC RR OXTMBMAININI P'boCl• YOu Aw�se.MW°n�w1.: Stde Side IT B InR TEARRRT®AIB uwKD R YAmOI M�AYR�T MIS m a dY6lm a,a u6m R AB M NRRG CR066 6Fnw65•BiR6AG,wRIAM a omm VII v N w wRr NYOMIT IS a M: V OFIEBT� MINOR RE DPo[Si®110IM'=RP AIC!,311pl1 a 6R RRaG V'SRn CIRCUIT LEGEND CIRCUIT LEGEND ELECTRICAL SYMBOL$ 5410P 5Y1 „. AMN K1.T W AIaR „• aEIRr-Iru VOLT! IJERE NNE RUN M ENTRANCE PANEL Lbiran& it Bedrooms: 210.12 (B) REFER TO SHEET GN FOR NOTES DATE: I KITCH N RECEP 1 0 12-2 MIP 2 DISHWASHER 120 1 -2 0 AMP ENTRANCE PANEL (BELOW FLOOR PERTAINING TO THIS DRAWING. J KITNEN CR RECEPiS 12.+,12-72 12-] 20 AMP 4 RANGE RECEPT 2s0 S-J 40 ANP ® EXIMPT Fa CRAWLSRACE) uits that supply 125-volt, single-phase. 15-endiUTgt ! U.L APPROVED (AC-0C) SMOKE DETECTOR tlets installed in dwell) unit bedrooes11 ITNEN UwTS 120 14-21! AYP 10 REAT ROOM 120 14-2 1! AMP ® UL AINPROVED (AC-DO) CARDN MNOMDE DETECTOR by an arc-fault circuit Interrupter listed to II DEDROOON 120 14-2 15 AMP 12 ADI ALL 12 I4-2 IS AMP . ection or the entire branch circuit. 13 A UNIT 110 14-2 15 AMP 14 WATER HEATER (4500 WATi3) 240 ID-2 2! AMP �A ( OC) SYd(E DETECTOR (BELS INSiMI£0) 1! SPARE 13O 14-2 15 AMP 1 .lVl WALL FI UKMLIW YQNTUGHT D FANnXTU ( NOTE: THIS PLAN CONFIRMS 17 I! (� ❑Ni FI%NIIE W/VENIED FAN (50 CGM MIN) 1 SEDRON HEAT 240 12-2 20 AMP R0 BATH HUT 240 IZ-2 20 AMP me 240 VOLTRECF➢RCAL TO THE NYS ECC TABLE 602.1(1) 21" NIINEN NEAP 240 12-2 20 MIP 2 GREAT ROOM HEAT 240 12-2 20 ANP 2] 24 1/2 SMTCHEA REUPRCM 25 25 Rao DUPLEX RECEPRCAL 27 S • SINOIE POLE SWTCH %N 29 JO 4 J WAY SMTCN31 32 y-Ir,O�jf• OC ~(� ,JE f 1 J] 34 B AINCRN BOX S FFC JJ JS RECESSES TINT FIXTURE yq Op 40 O WALL MNT FIXTURE OVER UV. 9 3 THE s TE�� M Mr f_ r On [y� 11 $ s w II I Iw GREAT ROOM % / GREAT ROOM ON, I , i (MSA /� . lf MAL fAOEMMIE I L '�j N' MICF.IETAL ` ��'Y dFALE.„Eru COOE1C1011 l r' EFACE.1'Eru ISox4ouE L---------- N vor. ISWt4WIE 10 ,u.. I S ;TC`.eoX 411EE -r,, Y O m I , " .; i , ;' \, Ul, ELECTRICAL SAME AS L------------ , I 4 0'=== ---j L UNIT TO LEFT t� I BEDROOM ------ll I I fr__ _______ f Is Y • i In ` � F @ FORM f I III ° SU MR 5EDR2 1 MY I IarcHEN aK G EI ` - Y 1 •�ruIT H 1E I 41MK C °0 BATH Oa I 11 ' 6ATH II EFT;it I al . 1 , , '' ' " 1 1 .. , 0 00 , L-y------------------ 1 I R 1' 1 o SNFl; o o 1 11' 1 LA-ELECT, r IL a 9 (`------------- 11 - i' _ �JIONG�MrNb MC iWaCall "1P1n ' "HA rYSiDtILaI Side us �MINGT S. N mll CONN few "xT"DMCOL'TO THE oMANM+o, 0011 THAT IT O NOT 10 L CORED a FIRST FLOOR ELECTRICAL PLAN 22, 11l :M PLFIL PLAN LAYOUT` laEa. THE OINTIVI MY NOR EE NSnosm N EAR[a Y RM!TU 011OM OR U!0m INNER THAN THE Full m� Now THE ENIII 01111114 INDINUSION F•J- a Ea MRWIIC SYSIOIS MC 9VIOP BY$' DATE: DRARUAGE,YIASTE AND VENT PITTWGO WATER SUPPLY FITTIN66 cw•eeTea ro vrMr pQ°U TAG DEKwP 1014 TAG DESCRIPTION rNwxN Koor lura • > •�MTy M ' APFlUP14iE NTN66 O 1 1-IA" 45' ELL I V7• SO•[LL y F T• y N' 7 1.112• B0' ELL 7 In' W- STISET ELL I 3 1-IR"WE 3 1/2' TEE 4 I-IR" LONG TURN rY 4 3/4" 00' ELL O Y ,,--aa•• S I-I/2• SANITARY TEE 6 1/4, 791 6 1.1/2• TEE 6 3/4'MF"T F ' auuw r Y qT.•Nf n O T I-1/7" P-TRAP (BEE NOTE 1 3/4•x1/1' SO' !LL LONG SUEEP 1/4 OENO S 2"xI- 3/4•.3N•xiR' TEE 5 `fl O cPrION4L at O j3�F{ /+1 S CLEANOUT W4^LU3 ! 3N•aVN`xV2'TR W 1"xl- � n • H y � O I!!'.I-V2'al-I!2' DDLFIM •• •T y 11 T•4S' ELL LEGEND }], 12 IV L0• ELL --- OO.D WATER LINES •. gl 6 24 113 7-WYE —__— NOT WATER LINES K 6 114 7" LONG TURN TY WASTE LINES �p O 15 7"SANITARY TEE — — VS - G m lO SUM DIYN � 6 21, TEE � SWT-Ow -Ow VALVE ro IUM pYM M 7" 1--TRAP (SEE NOTE IS 2- LONG WEEP 1/4 PEND D.W.V.-IQT(k1EN D.W.V.-HALL{A7H h6 7'CLEANOUT WI LUG 770 7"DOUBLE FIXTUIRS "• T IIf ;71 Y 4V ELL Y 27 3. 30'ELL E ' ryyYR 23 3" WYE 7, K' N4 3" LONG TURN TT' 9 E IUr MK 80 3" SANITARY TEE p0[ w' 76 3" TEE 71 4"x3" CLOSET FLANGE O y, LAV 76 3" LONG BLEEP I/4 d. g I 7!9 3" CLEANOUT W'PLUG 30 3"DO ISLE FIXTURE •• 5 J / I >/4• I SI 3" LOM^ TURN ELL n N•� O 37 7'4"xl-1/7" WYE YQ 3 / `� • • 93 3"%3'x1-I/7'WYE y / stn• 'J4 3N3'.2" WYE i.q ccT+Kcr To tuw Tr°ua• 36 7"x7•zl-IR' LONG TUR! TY KPFLT Lwp 36 3"xS'xl-IR" LONG TURN TY 'n 31 3-x W2- LONG TURN TY 36 1.1/2-x7' wSWING y 39 H/2•.3" muses NG 40 7"x3• BU614ING N-� Z W.S.-CTCK N W.S.-HALL SAIM At 7' CONT.W 314' D.W.NOOK-UP CD 47 7'x3' INCREASER 43 4"x4'Y9- LONG TURN TY 44 4'.4'x7' LON2 TUM TY ., 40 4".4.041" LONG TURN TY 46 4" CLEANOUT WIPLUG _ •• DOUBLE FlXTUIff TEE OR DOUBLE COMBINATION WT'E NJD IM DQJD O L c lu �O Q FSH ST�T E�/ � •j 'M oOUIRxT IS W RmP61TY 6 W SM oIROK mUSm MG Km KQo4V15 MODEL, US N11g1�T 1672 S(da ekj 51LJO ro6 TTrum�6ro1x�6m wEEl.T`mi[ DRAA44% OROlm N b y PLUMBING REFER TO SHEET GN FOR NOTES Oo•/ 1wl mmoK0,m wMu 6Sw r4m PLAN LAYOUT N Iplu m MM I't MY UI1QjU01�111m� PERTAINING TO THIS DRAWING. Tao6u �6EF�K SWEET. 6 Komi TUE lTOfRb�mm MR16SOo IF 6M ll I m6M9 m U � BY. LOADS SHOWN FOR ON SITE REFER TO SHEET GN FOR NOTES DATE: DESIGN PURPOSES ONLY. PERTAINING TO THIS DRAWING. ZERO LI T LINE ZERO LOT LINE 00'-011 20'-011 20'-011 20'-011 " � o F----------------------------------- ------------------------------------ ------------------------------------, t I I • � r--------------------------------F------------------ -----------------7-------------- ------------------ NOTE, ------------- -----------------NOTE I T i m I I CRAWL SPACE 4CGE55 4 VENTILATION I I DESIGNED t LOCATED BY BUILDER PER I 1N I 1 5TATE/LOCAL CODE REQUIREMENTS. I Ln I I 1 I a + } -74" y'41jI A3 ' 31-811 1 V11 31211 Ji2131211 312� 31-111 31-111 31-111 J1-III 411i E ri *C I I r___r _r r___r r___r r___� r___r r___r r__"� r___r r___� r___� r___r r___, r___� I I I �I I I 1 11 I I 11 I� I ® IIL--- I ` L _J L _J L _J LL _J L _J L _J L _J L _J L —J L —J L _J L _J L _JLL _J L _J I ii 1 3987 PLY 7983 PLF I t 3983 PLF I ASONRY PIER ON I I CONCRETE FOOTING II (TYPICAL) I I ------QTE I 1 REQUIRED SEPARATION BETWEEN REQUIRED SEPARATION BETWEEN I N I I BUILDING AS PER GOVERNING CODES BUILDING A8 PER GOVERNING CARES I 'J _ I I 1S THE RESPONSIBILITY OF THE 15 THE RESPONSIBILITY OF THE I b BUILDER BUILDERIn I S CRAWL SPACE I I I j I I 1 I I I I I I 41i 606 PLF OUNDATION NDATION II WALL FOOTINGall L--------------- --- ---------- --- ------ ---- ----- -� I------------ ------'-------------------------------------------- --------------------------------------------------------------BLDG. # 1 BLDG. #2 BLDG. #3 (2 STORY DUPLEX) (2 STORY DUPLEX) (2 STORY DUPLEX) Mm ,u lax Y wn�wr l+ rte !tea A n• FOUNDATION FOUNDATION PLANS 4�.':. a�NLAYaT �P. wq•�1rA SHEET. .SIR.[� M.l1! Y YM lIr� / 1 LIGHT 1 VENT CHART wlfmWSG®IlE S110P Dri 7m mgp - H w• r / TO 13EST OF HIS/HER KNOWLEDGE, w• os u n w LN '��""µ DATE •MnNiu uwR 11"MISE EXTERIOR DOOR SC1IDJ_E �� <� nG ^�, BELIEF, AND PROFESSIONAL JUDGMENT: T rMFT, , M� r THE FOLLOWING NOTES APPLY LEGEND fr rve.r - w w *I - 1. THESE PLANS ARE IN COMPLIANCE WITH OUR Dmam mcAna ru.MGMA ar Awlrovu A NEW YORK SYSTEMS FOR DETACHED ONE- ® MA.AIrNDIb IA^rt+G1 wa o[m+on I.R. . MA ..�v.. ,w.DG7 cAAFo.MaaNx INTMIB4 DDDR SAMULE 'i /�. AND-TWO-FAMILY DWELLINGS, AND MULTIPLE ® nrwTut 1mrAr r3 _ _ SINGLE-FAMILY DWELLINGS (TOWNHOUSES). W. w it NL mei \ THEY ARE DERIVED FROM A CONDITIONAL IIioU) �" I I"'I lmwm Em mm "rio 9 . of APPROVAL OF OUR SYSTEM MODELS. nut.auTc.le�4...NavLL ``ir" s1 n'F APPROVAL DE51GNATION M0052-02-062. DATED JANUARY 17, 2003. MW LOT LNE SER7 LOT LME •.w��v,�r�«F.wo.,. 3M 14 b M I[MILT ALYMDING N WX N.ne..nN o.n. 19'-1011 1" 19'•10" 1" IA3'-10" = FG FG UNIT I AIRSPACE UNIT 2 AIRSPACE, i -11@" 4j" 4j' 15'-I�" 5j" 3.6 Y�" 4J5 6 5j. uP1rc3 14' y: NOTE: 8 $IpEW.W.. MATEW , GABLE ENO HALLS AND U1,305 ZERO LOT UNE MALLS ME BUILT m RIE SIANDARM Q MEMM 3 4 METNW 5 STAT® IN SECTION 8501.103 5'•m" DF THE ]000 1 R D. THESE M WS ME r—a/0"FL.TTPE ACDFFTAME IN THE SBSMIG DEEM Leah TWIN-3067 C C87li THIN-3052 C.AIEG(WY'C ANO MR MND SPEEDS di �" �' C52% 1i3052 'X'ORI'W4L •A! 110 N.P R S -Im EGRESS EGRESS REFER 3i' EGREeS M1 REFER TO SHEET GN m 48-ero'U.u.Ve•a 36. 31• 16.510,U.+IM'uJ 3i' ]e' I1 —� 4eMITOILL.6rc wrt a .D FOR NOTES PERTAINING !RL"FaR°tc wll qp.POR AJC uuT P.C.C..FDR TO THIS DRAWING. 3 W�W 1.jL.r 4 GREAT ROOM GREAT ROOM GREAT ROOM W oW Oro ' QP STAIR (� )-•\\ PINE 6TAIR PPE STAIR /VINO 0 + LP! LINE RFTGHEN }Y �D KITC n• F ]F nea KITG L PAWL PANEL C2:.1N DP43 I PANEL EL j 1 a a rLEIS ,� 3 iv pL ----� ALa,. 9 7418 W1 RANT£41O! , El O . y '. E� Q ______� -_—--_I TLE55 AL]IM c0 W30N NG<7D r]1 OUR» - (11 g1TLE75 3/�F 4,-Ip n .Co��I1Lat GGTT��uuIl 4� ,3 a f' =� mwTLEm -m fL E T 0836 8036 ELECT. 9EDEPQ gP.DF?p • ELECT 0836 w w L C ELEL7, DBIS I pgB -_______� v_______� O D O DLa430 DL1130 D lO �O 0 0 � =430 41�IY _ q .➢ ® WD50 ] l� f]11n RR A ® ® � 1a1V1FLR D3 _!w `f 3J' (4/SRDe RVSN CEILMfS r4)S . . . . U/5RD8 R _W f 15nDe f118 5 UBN LEI 418 " �l � . 106 IR 3a RI04 5/8 __-------------- - nns . : ; • . : • . ; fll!•V4/LV,LVL IffQ'D 4CN HALF ______. __ ._.._ _- _ ___________-__ fADSET i/ 03•I 1'I QWEr (L!-V4/1-IN LVL.REDD ETCH N4lF ABONE (Lf-W/i-W L.V .KG9 EAG11 HALF I%/ • w ' �o A.Mh 8H 1'i - (A Dl1EDIdA '� /' `� /i GD DETEGTGR TA 0e18GTLR CLOOEI 1i W.1 11 .D O nr VOF r m"BI•FOL • - 01-FOL IV 0'BI- 4a'. J' - a u 30' 3]" u 30' 3]" 11, 30" '�BATH ®BATH BATHm oa a - V 1`04II11R o � DgL1 yyL _ y 5EDROOM BEDROOM BEDROOM �b1 31 i'i i CLOWTt .. CL06 N i WALK-Tf. tty Qf3SET ager W 1D Yl� 3m" 30' ! 3r 101 EGRESS EGRESS EGRESS gg �j 1WIN•3057 TWIN-3052 TWN-3052 O ■ YI I P10DEL. TINCS: 611 5'-Il1' 14111 131.5" 42j" 4j' 13-1 ' 41" 5'-11. 481114k5.-111.tf 3 = STAIR NSR WALLS ULv iM.` GR8N8N0 UL305 = ZERO LOT LANE HALLS ni IST FLOOR UL3 = EXTERIOR WALLS 'j,,,,, MMw PLAH LArouT UL34141 = IING WALLS # 1 UNIT #2 FIRST FLOOR PLAN UNIT �# 3 .M1e ..... UL638 = CEILING ASSEdlBLY . 8'-0 CEE.NG Iw in.rr Y LIGHT A VENT CHART WINDOW SHEDULE wamikki w"avrww &W6 sow. E"n. "HrAaA• A. . An in IA•liwN ". r n _ µto -HNA NOTE- $I�OPCYt e"w wIm• 1 uw ..E 1 su n aw •"" -- ,s5 .- r+ 1- TO THE BEST OF HIS/HER KNOWLEDGE, pg7E; �' w GYM^ BELIEF, AND PROFESSIONAL JUDGMENT: E%TEPodt DOOR 9CNEOlIE s`,'0 THE FOLLOWING NOTES APPLY LEGEND . o[ra�LacATw.a xaourcAn.wu _ " _ Ix 1. THESE RK NS ARE IN COMPLIANCE WITH OUR NEW YORK SYSTEMS FOR DETACHED ONE- ® u.L.Arrnom ONE- I.) UTrcrc31 'q „ , ' fi AND-IWG-FAMILY DWELLINGS, AND MULTIPLE ur_A.rnN\sn(Ao-x).wmm"3 ^ IMERIRi DDIXt SCI1E01A.E 1 _ f SINGLE-FAMILY DWELLINGS (TOWNHOUSES). ® ara+an twourlmrArr.l � *•' ' "," w c � THEY ARE DERIVED FROM A CONDITIONAL ' ® .�tt1O11 J a u y, my \ n4 IgIW CNE flYw 2 APPROVAL OF OUR SYSTEM MODELS. R N'w' •" "'•"N"' w'" °''r _ -- re°i' APPROVAL DESIGNATION M0052-02-062. ' .•F]IEIAN! QmTaM1eR Ann1EOVAL ' Nes DATED JANUARY 17, 2003 AFRO LOT LK ZERO LOT LME ��ya,. ra H F"�mw.i�m MR Hors "M"NNww N.TL 191.1011 2" 112" 191.101, u nulloaNAnUNIT 4 AIRSPACE UNIT 5 AIRSPACE UNIT 6 NOTE. .. " 5 " II " 4�" 4�' II I�" 5 " 3'-10l'I 4J"3'-q" 5 " I4'-5 " 611 Yj sIDMAEL. HATI N,RRLE END MALLS AND UL301 ICAG LOT LINE WALED ARE Q ELI, TO THE STANDARDS f1E NETHM 3 5'•0' T h METHOD 5 STATED w SECTIDN R6D2103 wFC.T1ff LLL GE TPE BE IN THE H LRH, THESE 4ETNODs ARE ACCEpTAmTWIN-3052 TWIN-3052 TWIN-3052 W ORnLALI CATEOgtY 'C' TER qR % DE ND SPEEDS OF - {Y3 ttD NPP, _11A I EGRESS E35RE55 EGRESS REFER TO SHEET GN `m Ir 7p -aI-WAI ve'H B-5re^aAH-ve^K 24' is �-em•Iu"H-Im•a FOR NOTES PERTAINING RO.FOR Arc WIT RO.FOR Arc WIT I FW,MR AIC WE TO THIS DRAWING. GREAT ROOM GREAT ROOM _GREAT ROOM .n LINE w U DND� MO s� CIRIM All F 7 . .In L iZc u+— G KITS N l Pln' 7 6 �ANB- I"A7eL � , eaAEL VBIT BOk a a VENT wx VENT BOX AC24% f]1 WTlETe 3)ACF I ,�gg Gf F/ nX2 ETb 4 8 ' 5B3tr ee3H 4'-10a" 4�"n'8" 85m i$ D515 O O O O 0518 DB5 O O 0 eCR36 S !9 OC1130 DUtlO O O H 1N ° O DCA130 SEA t 6I W83O 73 7 e630 W83m A. • 4 _._ _-_ f7Z KR ..• CEILNkli — r ___ ___-____`_ i//IW\l1 1 O.N 1'i 4L B'LVL REO9 EACH NAIF __- OitO71 R10 GEILNi f31811D! 1� al r,� MUSI 5/8 rvenloe tv R.R 11rw wu 11 Wu awl ••• rn RR (3)SILOS 106 IR 1•ry/- (I� USN EIL i=.�\ m _ SdCLOW ••• 1 ( B F,VL.MOP EACH CRALF ABO :\ OSEf ,co DerecTae ' • ' \ _ REOD EACHF ABOA 1 . � 1 /i / \ I 1 . I I 1l tY/RIU/i _ 0"51-FOL DETECTCR \ O'51-FOLD OF 0°BI-FOL m_ �• N>E Z 30' 6'4FF 3] 30" \ A'AFF 3® L _J L _J 30" • 311 �NJ 2 W 0 64TH BATH � 154TH wC iD (] Nd6 N0.51W NAS W" ; 74ilR DR O .. etuR bH ODR Y UVLALILK- �M BEDROOM BEDROOM rl. CUORTM BEDROOM m 1"y)v I \C EGRE55 EGRESS I EGRESS �� �Zy m TWIN-3052 TWIN-3052 ,I TWIN-3052 Ac_alk S. LOCATION 61, 5'•I#" 41 " 13'- 31 5�" {�" 4j' 1 -1j. 41" 5'-11 48"' 11141' 5.44* '71 13.58" 6" •_nm.wN...�.N. loo Duplex 7VP3339 = STAIR TOWER WALLS F" ^' OFAM CitAu"]1 Inlww n'�L—MA"rw�""L lND.FLOOR UL305 = ZERO LOT LINE WALLS J( w+. UL341 = EXTERIOR WALLS - J(_ �_ SECOND FLOOR PLAN Tom- 40=31, •�' PL�2 AST UL341 = MATING WALLS UNIT I UNIT 2 UNIT 3 yam, U1539 = CEILING ASSEMBLY W-0 QII SFIOP BY, DATE: X110 LOr LWG ZM LOf LM 1J IELD INSTALLED RIDGE VENT 1 1—ao—'icv -�iir— ra nnae va+r 1 'r- uo booe+slr No wcr>E sur rn m DELETE GABLE ENDS I I I I I I I I I I I I OVERHANGS - -DELETE GABLE OVERHANGS ® _ Til_ ILIFm LL C z aS LL _ 10L ME) o0 00 00 � �� w J_ nh 0o as o� as as ? � s 0® - an n0 �0 UU a0to Ff;P,ONT ELEV,4TION < VH� J L EXTERIOR LIGHTS SHIPPED LOOSE STOOP'S/STEPS t HANDRAIL 16T FLOOR HORIZONTAL VINYL SIDING FOR ON-SITE INSTALLATION BY SUPPLIED 1 INSTALLED BY FACTORY INSTALLED BY SBS., 2ND BUILDER BUILDER FLOOR SIDING SNIPPED LOOSE t FIELD INSTALLED BY BUILDER plax f �lwil M�auw GJI REFER TO SHEET GN FOR NOTES LLSELEVATION PERTAINING TO THIS DRAWING. AMCM SNDP BY: DATE: ODULAR MATCH LINE ODULAR MATCH LINE IELD INSTALLED RIDGE VENT IELD INSTALLED RIDGE VENT yy SSSf��� e 12 Al ® p LL T U Z z l O O LL I w U U 3 LL LL � N V l ia Z LL LL A i LEFT ELEVATION F;PIC�NT ELEVATION GABLE END HORIZONTAL VINYL GABLE END HORIZONTAL VINYL SIDING SHIPPED LOOSE A FIELD SIDING SNIPPED LOOSE i FIELD INSTALLED BY BUILDER INSTALLED BY BUILDER j MODeL. Duplex --- .,'•� ..•'�w'w'�r+,�a�ww�ir DIUNNo: REFER TO SHEET GN FOR NOTES ELEVATION PERTAINING TO THIS DRAWING. $HMT, 314 w wn wwsws Iwl 1wI N www[•w� � I 5FIOP syr DATE =0 LOT LM ZEFV L t LINE 1 IELD INSTALLED RIDGE VENT 1 = 51-01 15 0" Fl FF NO RIDO! MTI—� W MDGE`.W NO PoDGE,Dn }} yy yQ o CIA DELETE GABLE ENDS OVERHANGS ---DELETE GABLE END e OVERHANGS , ZU 1u p U J F a y mS SO VY � L J LL �C LL a� nSl 3 oLL Z � z LL V) M LO _ NL± O REAR:ELEVATION t(1 EXTERIOR LIGHTS SHIPPED L005E STOOPS/STEP5 4 HANDRAIL IST FLOOR HORIZONTAL VINYL SIDING FOR ON-SITE INSTALLATION BY SUPPLIED " INSTALLED BY FACTORY INSTALLED BY SBS., 2ND - BUILDER BUILDER FLOOR SIDING SHIPPED LOOSE 1 FIELD INSTALLED BY BUILDER aF i pgDp-. ' Magi"wr R v[wean v .� =s DRARM REFER TO SHEET GN FOR NOTES w� 7'"'aTo" ELEVATION PERTAINING TO THIS DRAWING. eweTB . dV:R VI�ME,1�1 " I YI YM ed Mu OR 14d-10x16 FICIRWILAS5 SANSIM4W- 1-314- - air FL TYPE'X'DRrU"LL 9NOfT BY: . GA 6i4PLE61.OL PER RDGP CAP luaxe GRIST rA Tn6°euEAn7x6 sNE7 REFER TO SHEET GN FOR NOTES DATE: M BD.FOR R-IE INSULATION PERTAINING TO THIS DRAWING. SITE M6TALLATICN NBER3LASS 5FILO TV FLIP xl-NxK FLIP SAVVE� VNTL ND Nq iG DECKING9 WILDINGGA OTNiET 7 OGPER r RIGID ING. 7x10 FL.J016TPAPERTRIOS ROOF 6KATAMG AUK DRIP EDGE 16dTOEN4LIDFIUAEKIII�D IIRIM IELD GQFEGIYGJ WADI.FASCIA , h�' (,P O F'• d TOE NAILED ]xb sue,FASCIA I FIERI BLOCK PER NDE T "DRN4LL 7x6 GEL JOIST F P44F TRW PERFORATED 607FIT 5/5'DRYWALL I 70 W x 1 V4.6 RRf1T DW.TOP RATE . NETHN "ad TO TRIM, Flw� 0FnvTFlu R Glc'. EVERT ISECT V 7x6 STUD 1 ? NAIL wu.lod FER 11RB6 24 STUD•K'OL. VNYL 64DIWA Lp --5V Fr_rTTE'X' ' DRnUALL lid tte'D ING R-b I/ISLLATION l //� ��\\ rH er I'RIGID INT BOARD Tni NEarHSG / \ (�jROOF RIDGE DETAIL 2 FLIP E, E DETAIL 1 FLOOR/GEILING DETAIL 4� 4 4 9 SIDEWALL IT I RBER3LA"$5 ;LES m an RECD CGN+UL. M'XL0WOdUW GA J069 PER=414-TION \ -- WS)IVx'BE6 TO LWER JCO NFBER 20DJ-OK-7 'FL TYPE'k'DI6YYlALL O D a WLLDING PAPS RTS KM F'DsrERDEALER r RIGID 1Ne BOARD ]xi snlD.w oL 5 f e TOE 71901ROOF SAEATAFG R M61L417O1 VMTL 6DING LL 3]6 7 PRE CIF TAM 1/166NEATHNG 801.RATE @D iRla7 R- TI F'FE NAVFACiURffD IO G.%I III'STRAFED F,CM 3/I'TIG DECKING ROOF i14" (0)ftp PERRiDE6 I Fmk \ 4 m 16d TO MAILED \ elpl 16'OG PERPEIFR \�' .3T MNLATKM \ / R-38 MULAT FIELD CONECTION M.Ix PERM Bd)D6 M'DRYWALL 311 TIT'DRIW4L pQT d5 "LER S/T•DRNWI O ` •F.T.TILL RATE Ili 'ANGIIGR MOLT iN'TKA T/K'NIEATRIMG � d A RATE ]0 Gx X I VI.61R4PED gYl1 I, —7.b STUDY /6'FL TYPE X DRYEA,L 2.66W 611D 10 iRW I FA118R •BLOCK.POURED • '+ m .K'O.C. WY6)6d WII h PER END FOLDATIRI WALL R&D NNLATKN X016"FL.TYPE X ORT ALL 9 e/6'FL TYPE'x'DRTWUL 'RIGD INd1LdiIR1 BOARD O i __R-It MBLATION W 1x4 O1UD6 R-b W(WLATI xR 1 T4ERMO-PLY VNTL RID NTL 6DMG $ ES{ (�)ON WE DT OYER 37i iRip'10-PLT LL 37 LL 3N %.. L r3_'�MATE WALL TRUSS DETAIL EXT. WALL + TIGDECKTG 3/P 1G DE ]x m FLom JOISTS 're UNPAGED 3/4' -B UFACED 7 x10 FLOOR xlsl 1 4 4 PDN. DETAIL 6/6'FL TTPE'X'DRNNLL TAT•TKA 2 x 6 CEILFG J05TS ]x 6 CEILSG J016T 1116.5�TATG t LL 311 7x1 SND.K'OL _ Nl l6'F.C.TYPE'X'ORPLIALL 311 6/A•FL.TYPE'X'DRTYNLL 52'FL.tTm'x'fMTYAJ. RAID NRUATION UL 03S LL�•' 'RIGID M6JIAT OI BOARD m P° ixI STY!.W OG iKR'10 RY v1 x 6 slum /09 FL.TYPE'X'DRYWALL w 10'RYIIIDDD D07.RATE 7 x 6 S11ID Y3-- iHERTO-RT RTEOOD WOCKING 3W'TG DEGKMG DBL]x PERI BANDY V1NTL ND 16"FL iYPE'k'DRYWALL g TK'FL TYPE X.DRYWALL NYL 610MG -y p BOT.PLATE -R-b MSLLAGIW x16nD5 R-b MEULATI Z }. 31f'iG DEIXMG DW.1x10 PETM BANDS N JOIST•K"OL 1x6 OWLD-UP -UL 37i .RT UL 37 V]'xl0'T1RE4DED ROD a/(1)W4%e*I ALTS 45'or. W() I 17 11'iG DECKWG 314-7 G DECKI ]xi J016T 1x1 L au �,OL 1 1x JOIST A 1 x IS FLOOR JOISTS 1 7 x 10 FL�R JObT JOIST NAfGER III N6'DRYW4LL DBL Irl PERI.54we • T.SILL 841E II MCHOR BOLT DBL.TOP.P.A1E IMER'D-RT (� �1LL ftAIE ON WOIX PIER 7x16TUD•K'OL. 611E BT CP;E" -30 N511dTIO7 -30 MSLLAPG' (ON SPIE BY OTHEfdJ (ON NTE BY 07KRD/ (V ON 511E BY OIAER 5/6'FL.GTPE'X'DRYW4LL 'x16'GNU PER - • UL 3G - u/REMVRLNG U R14 MATE/PIER DETAIL FLOOR/GELING DETAIL 46 REQUIREDeMR LOCAL DEPOER Vth ham FASTR MG OF FLOOR TO FCINDATION MALL BE WITH V d NAILS.TOE HAILED MTO qq Y FERMM BAID6 AND NIL PLATE.W'a/c. i GIR055 5ECTION $ ML: 0TIOX M 100 AYx.TF��N or_4 l GRD86 7 Y 6E0TIGN >IR.uP•�•A�Rwww•rxn 65IQT: A FY:F1•M:F� �'F ,Mwa M^1111111111��RR��Q A I � UNITE 12 "a UNITE n. 7 4 9 ELECTRICAL SYMBOL5 6NOP BY: te CIRCUIT LEGEND CIRCUIT LEGEND HOME NUN TO ENTRANCE PANLL Dwelling Unit Bedrooms: 210.12 (B) REFER TO SHEET GN FOR NOTES DATEt N' E(RyRO v T I BAIL kWAX3IR N- SSRI vd.TG Um 1m,ocimot ENTRANCE PANEL ((BELOW FL(YX: q l branch circuits that s�Iy�y�I(� 125-volt, sl le-L�,�ee. 15-and PERTAINING TO THIS DRAWING. I NI GFl RECEPIs 120 1 -2 2 2 OISHWAGHeI t20 I!-2 13 AMP ® EXCEPT FOR CRA WAGE) TI- J � r""" 3 XIMHEN CFI RECEPTS 120 1 12-2 1 20 AMP 4 RANGE 2W 8-3 b AMP ILL APPROVED (AC-DC) SMOXE OEMCMR 20-ampere outlets Installed to dwelling unit bedrooms "ll 5 REFRIGERAI 120 1 12-2 20 AMP b . U.L APPROVED (AC-OC) CAREW MONOXIDE OETECTCR be protected by an arc-fault circuit Interrupter liked to 2 BATH OR RECEPT 120 1 12-2 7 20 MIP b TCXEN GREAT ROOM 120 14-2 IS AMP 0 BEDROOM WNE BEECTaBs 120 14-2 15 AMP 10 ATH LIGHTS 130 14-2 15 AMP %0 (AC-DC) SMOHE DETECTOR (FIIan N5rAL1£D> provide protection or the entire branch circuit. NOTE: THIS PLAN CONFIRMS 11 12 SPARE13 120 14-2 15 AMP WALL OR CEIUNG LIGHT FIXTURE TO THE NYS ECC TABLE 602,1(1)WATER HEALER 240 10-2 25 AMP 14 A/C UNIT 240 10-2 30 AMP LIGHT FIXTURE W/VENTED FAN (50 CFH MIN.) 12 15 KITCHEN/GREAT ROOM HEAT 240 I2-2 20 AMP 1B 16 BEDROOM HEAT 2!0 12-2 2O ANP 240 ver RECFPneAL 220 HEAT 240 12-2 20 AMP 22 I/2 SWITCHED RELEPDGAL 234 DUPLEX RECEPRCAL 25 26 • SNGE POLE SWITCH , yL 27 2a ♦30 3 WAY SWITCH JOB JUNCTION SOX 33 34 RECESSED UCHT FIXTURE _ qW 35 m Q WALL UGIT FIXTURE OVER LAV n 36 of oR F- N 1OW16 am s !nuw s BN 'aNM 2 ' ' I ' VuVWF. 1 IL/ a wN � ---i m �� ILII III L-------------------------u I - IL---------------- ---- W. P aTOioeD i I -- I I I 1 L------ III -----------' I `------�' GREAT ROOM _F�1------------ 1, GREAT ROOM I II GREAT ROOM I a I \ /� 800! KTAL\4�Y-----.-_� 0 ' `fr" , WACE,PETAL I �l�I, , aRAEF.MALI 5' SOX4WE ,�;(� ---- - I i' �. /-C`'•� oX IWm ;?-�., sox4 We IT H � r- 1 lZFTN,:HEN CEN II II I l 1 \ �� N I Me IR « .. L___________ � T ____ O O m T $ r___ Lf T trl �a I€ Rd ___ ___ __________ -I nl.__. w _ 410 e 1 1(I Dell(f.Tf.R`._ 1 _______________ __`___ i/ 1'i ✓/ 1'I ------------------- __ _ _ - __________ . . . . . . . . . . i i`` `4 /i ,i i1 CO DEIELTQI G20E1[CTIa! I� /' rA I L O O Iii ! pan ON/21 III ------------ COLOIL te 1110=V ` NI � an 0 I I I 1 \1CT. MN ATBATH I ` 0a n yr �H� 9 WDLL PON fDUa I I . ____Ti L___________JI\____i OAL��ML PAN �iT DOW ML FAN 7 V4tt OCUO _____ nJ 1� , I \ BATH � \ , 11�/ ; / I I \ `. / i MY11'E74 `SIL Y OIP/IEE.I'ETAL `S7 DRUM' & 7`C ., sox I EY! _ 1 G� ;7 C •, WIX I USE eco I we a o yam!a N DROOM BEDROOM aux.N p".61 BEDROOM ES k 1 CLOSET I CLOW ��7 �g f1pE1 - _ \____. Til JE ______I ' If---------------------- 9 , � I R .__ vlescr. IN I p J '� O �a?t rZ am • O R ui v � UNIT UNIT UNIT 2 3 MODS' ELECTRICAL MIRROR F UNIT #1 ELECTRICAL SAME AS UNIT #1 Duplex (EXCEPT WHERE INDICATED) M WW ISRS DR°seI'' R WRIN R �1/�(pY�1y�y lar PLIR ELECTNC R •�1Y41� P� eN�rl FIRST FLOOR ELECTRICAL PLAN 5 SHOP BY, UNITS -4, 05 E Ne INIT5 -4. .5 E 06 ELECTRICAL SYMBOLS -� CIRCUIT LEGEND CIRCUIT LEGEND HOME RUN TO ENTRANCE PANEL LAIlbranch g Unit Bedrooms: 210.12 lB) REFER TO SHEET GN FOR NOTES barE: pNRyIHO MLD uEEle R `_ ENTRANCE PANEL (BELOW 80011 circuits that supply 125-volt, single-phase. 15=and PERTAINING TO THIS DRAWING. 120 ,{-1 13 AMP EO E%CEPT Edi CRAIILSPACE)2 d5HWA5HER U.4 APPROVED (AC-DC) SHONE DETECTOR re outlets Installed In dwelling unit badrooms .hall TCHEN GFl RECEPTS Y20 12-2 2MN4 RANGE 240 0-J 40 AMP eCted bu an arc-Fault circuit Interrupter listed to5 REFRIGERATOR 120 20 MMP 0 0 U L APPROAED (AC-DC) GARDEN MONO%IDE DETECTOR J2O 12_2 20 AMP 0 ISNEN/CREAT ROdI 120 14-2 15 AMP AC-DC) S4dfE DETECTOR (FlEID INSTALLED) protection or the entire branch circuit. NOTE; THIS PLAN CONFIRMS 9 BEDROOM SM E OETECiORs Iz0 p- IS ANP 10 ATH PCAITI 120 14-2 15 AMP WW ( TO THE NYS ECC TABLE 602.1(1, 11 12 SPARE @p I4-2 15 ANP � * WALL OR CEILING LIGHT FIXTURE IJ WATER HEATER 240 10-2 15 MMP 14 A/C UNIT 240 10-2 W NNP NGHT TT%NRE W/KNTED FAN 150 CPM MIN) 15 10 + 1AO VOLT RECEPTICAL ,] N1IOHEN/GREAT ROOM HEAT 240 12-2 20 AMP 10 �1bWEu. Cay Z0 BEDROOM HEAT 240 12-1 20 AMP 1/2 SWTCHEO RECEPIICAL 1Y BATHROOM HEAT 240 12-2 10 AMP HI. yo.' 21 22 WPLE% RECEPTGM ,O 23 W ze SINIYE POLE NITER _ W 25 46 SWAT SWTCH pp 27 25 .10 JUNGTON WO% JI 32 RECESSEDuCNT FlXNPE n\ - 34 J, O WALL UGHT Fl%NNE OVER lAVSi G p , 38 37 FF p( QT 12 � I I • i--------� �'I F WEE MAL ROxIIIAFS ORAM r e guFi� • KITCHENFOR U40LE EWrrnwzE T fi e R 11 1 FOR 11 i_ HEM PAR 4gtlEFINI �1 Ili VI06'E F41 li I 7PM I I to 00 pp �- i c: 4",0 amP -----' `-- ----- ----- /�_ --- ---------- ` J J '/ / `` j - - - r a'-4 ---- 7 i1 d �c woelsTar 1t 1 1I i' I , I;' fp ODEGIGR 0 z > APIA 1 � N i 09cn I ' i ;• II a a ,o •�;` 'ma FkTII SPAEE_MAL(r , •o am o o /; aamE wre • Eiw , , , '`, \ uau •n BEDROOM BEDROOM �� 0 I I I I L • z " a u, UNIT UNIT 6 "°°°'-' ELECTRICAL MIRROR OF UNIT #1 ELECTRICAL S UNIT #4v� p1 1St , �Ag..:" '". 2ND PLR ELeenae .• ,.�R•.•jl >r5+yMg I r'L.AN LAYOUT 5ECONp FLOOR ELECTRICAL PIAN ,: _ ZL p BY: DATE: N TiLo.�O DRAINAGE,WASTE AND VENT FITTINGS WATER SUFPLY FITTINGS TAG DESCRIPTION TK OESGRIFTION I 4'FRa•un rmMne Off\ �" 4PFIooF14n m MIo6 1 1-1/2' 46' ELL I I/2'90'ELL T` 7 1.1/2" ELL 7 1/2• 90' STREET ELL 3 1-V7" WYE 3 I/2" TEE 4 1.1/7' LOW TUBI TY 4 3/4' 90'ELL O • S MAI' SANITARY' TEE S 3/4" TEE ' lr'wYR y 6 1•V7' TEE 6 3/4'MPT xrt,we O Q l I.1/2" P-TRAP fSEE NOTE l 3M'xIR' 90' ELL �!< V• Cnxxl4L TT uV S 1-I/2"LONG OWEEP 1/4 BENS E 3/4"x3/4'x1/2' TEE :" 3 O s 9 MAI'CLEANOUT W/PLUG IU n 9 3H"xl/Txl0• TEE V � T O b 7"xl•1/2'xl-I/2'xl-I/2'DEL•Ixi •• o sT » It 7. 46' ELL LEGEND U 7. 90' ELL O --- COLD WATER LMJES �, 13 7" WYE N M NOT WATER LINES T O U 7' LONG TUIN TY (Q WAere uNe6 m Tc n4N�n4r+ IS 1' SANITARY TEC — — VENT LINES TOTW1puN 16 7" me t}7 6NUT-Ow VALVE Il 7' P.TRAP (SEE NDTE D.W.V.-12TQ•BN MINY.-H4u DATH b 7' LONG WEEP I/4 Ma ND 19 7" CLEANOUT W/PLL4 70 7" DOUBLE FIXTLM •• b xx 71 3" {S' ELL C 77 3' 90'ELL Mow 73 3" WYE 41 y 74 3" LCNG TURN TY 0 w SIT.ex{c 1 ' 76 V25 . TSANITARY TIE EE Il 4'.J" CLOSET FLANGE T O y Lav 76 3" LOW. SWEEP 1/4 MEND ♦ j F \ 79 3" CLEANOUT WPI.UG M 3" DOUMLE FI%TUIIE •• y i/ O 1 x• 31 3" LONG IURN ELL / ^/ 37 7'x7"x1-IR• WYE / �j. FWD 33 9"x3"x1.1/2"UKC � cOM�CT TO TUN 34 3"x3"x7'WYI �'' . TO MPFLY Lw 36 7".7'x1-I/2' LONG TURN TY W V 36 3"x3'k1-1/7" LOW. TURN TY C 31 3".3"4" LONG TUIN TY it 3p I-IR'x7" BIIS14MNG Y 39 I-IA'x3" MU541w. qq W.S.-aTA•IEN w.�-Hou�A7H 40 7".3" DUSNMG - N)b T 41 7' CONT. W/3/4" DLL NOOK-UP T 47 7'x3• INCREASER 43 4•.4'x3' L043 TLI N TY M 4•.4'x7' LOW TURN TT' N 46 4'x{'xl-I/2" LOW. TUIN }Y `q 46 4" CLEANOUT WP4Li � pY •• DOUMLE FIXTURE TEE OR Dp1MLE CID J COMBINATION WYE AND VS MEND5 in MoocL, - io mon• T.Mwno Duplex ' Y��Ym 4�Yxn DRAWMIG� REFER TO SHEET GN FOR NOTES ,M LMING MT PERTAINING TO THIS DRAWING. � I