Loading...
HomeMy WebLinkAbout45924-Z o�OgNFFUt�p Town of Southold 9/12/2023 y� P.O.Box 1179 h z 53095 Main Rd 4,,- �ao� ' Southold,New York 11971 .rry CERTIFICATE OF 'OCCUPANCY No: 44537 Date: 9/12/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 675 Skippers Ln, Orient SCTM#: 473889 Sec/Block/Lot: 24.-2-1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/15/2021 pursuant to which Building Permit No. 45924 dated 3/15/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Orient Realty.LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45924 10/30/2022 PLUMBERS CERTIFICATION DATED �UIAON/- NAML�; - - toriz Signature �suFFoc,� TOWN OF SOUTHOLD ��o coot' BUILDING DEPARTMENT y 2 TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45924 Date: 3/15/2021 Permission is hereby granted to: Orient Realty LLC C/O Ivy Crewdson 61-69 Pierrepont St#51 o Brooklyn, NY 11201 To: install generator as applied for per Landmarks approval. At premises located at: 675 Skippers Ln, Orient SCTM #473889 Sec/Block/Lot# 24.-2-1 Pursuant to application dated 3/15/2021 and approved by the Building Inspector. To expire on 9/14/2022. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO-RESIDENTIAL $50.00 Total: $235.00 Bui Q Inspector SOUIyO� 9W5Nq0FlOUTHOlLD STOBUILDING��DE;WT. coutm�� 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ 4] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE '`� �a INSPECTOR �o��pE SOUTyO6 Ll 59 ! S— # # TOWN OF SOUTHOLD BUILDING DEPT.' °`y�ou►m 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] ,INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) )_gVELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: CeLl klg�DATE 0 INSPECTOR OE SOUlyo6 # # TOWN OF SOUTHOLD BUILDING DEPT. �o • �o `ycourm N 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAUL ING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] .FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DAT y INSPECTOR pE SOUryOlo Town Nall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin@town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Orient Realty LLC Address: 675 Skippers Ln city:Orient st: NY zip: 11957 Building Permit* 45924 Section: 24 Block: 2 Lot: 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Custom Lighting of Suffolk License No: 38893ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 20kW Generac Generator w/200A Whole House Transfer Switch Notes: Generator Inspector Signature: 1 Date: October 30, 2022 S.Devlin-Cert Electrical Compliance Form Mariella Ostroski,Chairperson oor U,,; Town Hall Annex Anne Surchin,Vice Chair `,��9 4�e tip^ 54375 Route 25 Allan Wexler `ye� �w� PO Box 1179 Fabiola Santana a HOLD Southold,NY 1197] �ouika�o Tara Cubie ® U=Vag rX ° Telephone:(631)765-1809 kimf@southoldtownny.gov Jeri Woodhouse , ra%d o Marina de Conciliis %10 + Kim E. Fuentes, Coordinator A o0 ER tot, Town of Southold Historic Preservation Commissio � J Certificate of Appropriateness AUG 3 0 2023 June 22, 2023 RESOLUTION #6.22.23.5 r,va'M4G DEP'. RE: 675 Skippers Lane, Orient,NY. SCTM# 1000-24-2-1 Owner: Orient Realty, LLC RESOLUTION: WHEREAS, 675 Skippers Lane, Orient,NY, is on the Town of Southold Registry of Historic Landmarks, and WHEREAS, as set forth in Section 56-7 (b) of the Town Law(Landmarks Preservation Code) of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit, and, WHEREAS, on March 20,2023,the applicant's representative, Peter Marren, submitted a proposal to legalize an as-built hot tub on residential property; and WHEREAS, the Commission determined, during pre-submission conferences,that improvements including a Raised Shingled Terrace and the Shielding for generator and mechanics upon this residential property were inconsistent with previously approved Certificate of Appropriateness, Resolution#03.10.21.1 dated March 10, 2021; and WHEREAS, the Commission determined that an outdoor shower is also "as-built" and will require approval; and WHEREAS, the applicant's representative presented Commissioners with Architectural Plans and photographs, consisting of a Raised Shingled Terrace/Balcony attached to the single family dwelling, 4 feet high mahogany fence surrounding utility structures, an outdoor shower, as well as the subject of this application,the hot tub; during a public hearing on June 22,2023; and WHEREAS, the applicant shall submit to the Commissioners photographs of the finished improvements upon completion; and Certificate of Appropriateness, HPC, Orient Realty, SCTM No. 1000-24-2-1 Page 2 WHEREAS, the Commissioners may conduct a site inspection of subject premises once improvements are completed; and RAISED SHINGLED TERRACE/BALCONY: NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines that the photograph of Raised Shingled Terrace/Balcony, Page A.1, submitted by Peter Marren,AIA, dated May 25, 2023, meets the criteria for approval under Section 170-8 (A) of the Southold Town Code; and BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies; and BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the commission. Motion made by-Commissioner Ostroski Motion seconded by: Commissioner Surchin VOTES: AYES: Commissioners Ostroski, Surchin, Wexler and Santana, Woodhouse and de Conciliis. (6-0) RESULT: Passed WOOD MAHOGANY FENCE SHIELDING MECHANICAL EQUIPMENT: NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines that the 4 feet high Solid Mahogany Boards surrounding the mechanical equipment to be extended, and panels be spaced 1-1/2 inch apart,meets the criteria for approval under Section 170-8 (A) of the Southold Town Code; and BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies,and conditioned upon the submission of Revised Elevation and Partial Site Plans depicting the aforementioned approved criteria; and BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the commission. Motion made by Commissioner Ostroski _ Motion seconded by: Commissioner Surchin VOTES: AYES: Commissioners Ostroski, Surchin, Santana and de Conciliis. NAYS: Commissioner Wexler and Woodhouse. (4-2) RESULT: Passed I Certificate of Appropriateness, HPC, Orient Realty, SCTM No. 1000-24-2-1 Page 3 "AS BUILT"HOT TUB AND "AS BUILT" OUTDOOR SHOWER: NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines "as built"hot tub and "as built"outdoor shower as depicted in photographs (Labeled Outdoor Shower#1, Hot Tub#1 thru#3) submitted by the applicant's representative, and received on April 5, 2023,meets the criteria for approval under Section 170-8 (A) of the Southold Town Code; and BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness, subject to approvals by all involved agencies; BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the commission. Motion made by Commissioner Ostroski Motion seconded by: Commissioner Surchin VOTES: AYES: Commissioners Ostroski, Surchin, Wexler and Santana, Woodhouse and de Conciliis. (6-0) RESULT: Passed Please note that any deviation from the approved plans referenced above may require further review from the commission. Signed: Kim E.Fuentes Coordinator for the Historic Preservation Commission Date: June 22,2023 Fuentes, Kim From: Fuentes, Kim Sent: Wednesday, August 30, 2023 8:22 AM To: 'Peter Marren' Cc: Bunch, Connie Subject: HPC - Cert of Appropriateness - Orient Realty, 675 Skippers Lane, Res.#06.22.23.5, dated June 22, 2023 Attachments: 675SkippersLane.fencePART SITE.pdf, 675SkippersLane.fenceDRAWING.pdf; 675SkippersLane.fencePHOTO.pdf Peter, The Commission reviewed your photographs and drawings received on August 25, 2023, received via email, and expressed their approval. Thank you. Kim E. Fuentes Board Assistant Zoning Board of Appeals Coordinator, Historic Preservation Commission 631-765-1809 khn�,southoldtownny.gov Location: 54375 Main Road Mail:P.O. Box 1179 Southold, NY 11971 From: Peter Marren<pm@marrenandnewman.com> Sent: Friday,August 25, 2023 3:32 PM To: Fuentes, Kim <kim.fuentes@town.southold.ny.us> Subject: RE: HPC-Cert of Appropriateness-Orient Realty, 675 Skippers Lane Hi Kim. See attached, per your request below (see.yellow) ? Part Site Plan ? Plan & Elevation i Zoning Board of Appeals Coordinator, Historic Preservation Commission 631-765-1809 kianf Aoutholdtownny.gov Location: 54375 Main Road Mail:P.O. Box 1179 Southold, NY 11971 i 3 675 SKIPPERS LANE ORIENT HPC 25MAY23 PRE-SUBMISISON CONFERENCE PETER MARREN AIA LEED AP • JUNz 2023 D� (ENLARGEDVIE TOWN OF SOUTHOLD HISTORIC PRESERVATION COMMISSION r fj u EXISTING GAP 7" s INSTALL 1/8" ROUND WV STAINLESS STEEL CABLE MOUNTING WITH n� THRU-POST FITTINGS USING CLASSIC O� BUTTON ASSEMBLY ID t JUN 2 0 2023 TOWN OF SOUTHOLD HISTORIC PRESERVATION COMMISSION A Y Ili 1 4k I Wa..�,r' c=am. Mt• <., , �Ilk nz, —v -- , Ak . `k :08 ZI— , l je !r AV ,� ! / �:, �.:r- i. r ,l rh•. � y�+.. � � .� �'� � � + 1. l _lt` �Y P�+r •.r s.�.. ,'•f•.fs x. •f, .; aa. ;. TRIC E'SER ATI N MMfS N 6755kippers ' ' ' 'ent ar23 ,r ,�� �_ � •�. (GARAGE) r r Or r Av- 41. 5 JF • �n fir, x ° IA �� y _ + P r .. �.• �• f r br /'' - �t ••:,# � ��w'. 'til.`� ,+�y .,+< � ,� �' ;ti*���� � . .��"'• IL r r. � 1 �,, � � T ••�` ski ` y.\�, � 1� � .,, ' i �i s F 'R'7 � �� ti•\piw v w" __ • _ j{ ■u��ll _1..__� i � j i HOLD HIST_ 6755kippers IN .� i' t Orient 3oMar23 •. �.r',�' t •.• . r� - * (GARAGE) .4 r w �. H OT TU B rf AAL r a ' , STs .�. ,• j� �F-�`,_�l�y i. ale � _.d F� � ' �, — • . � - _ _. ri PIN rA ,r t y i r 1 i 1 i i 401' ' - f F 1• s :I r -i 1 T r 7ti. ♦. r...=4'\n.x•17 . « r t � T r �1 } T rt • J ��,F � � •�� _ Vii . AUG 2 5 2023 To OFSOUTHOLD HISTORIC PRESERVATION COMMISSION ' �- EXISTING GARAGE I n � ! a I i aaj v i4 CONDENSER i CONDENSER W GENERATOR i a€ PLAN TVP SPACING BETWEEN BOARDS INCREASED TO LT j m ; i E f 51/2" 3" 51/2" 3" 5 ila" ELEVATION:11/2"THICK MAHOGONY BOARDS TYP ALTERNATING BOARD WIDTHS 675 SKIPPERS LANE ORIENT,NY j I MECHANICAL AREA FENCE i 14 AUGUST 2023 j I AUG 2 5 2023 TOVdN OF SOUTHOLD HISTORIC SERVATION COMMISSION EX'G CCNCRLIE SIDEWALK Ex'� '35.25' Pr LL ----------- NEW UNDERCROUND ELMR-C FENCE dq 3...7'.............. ...................... EX'G ASHIALT DRVrWAY 41' ..... ............... SLOPE PCICO. tk�VN ........... c- TO RE 4�- F,D',YARD SF'B<�l T— E v I S7D SLOPE XIAHO(�r)N',.' EXII TINC_: FENCE EXISTING of R A G R E I DE 1\1 C[ i 4 7-5 L EX'G spu-, FAIL M.lcl ji sLr SLOP[ 675 SKIPPERS LANE ORIENT FLAG-9LE NEW SCREENED N AD01T.10N J rL, PART SITE PLAN 14AUG2o2,, REVISED HVA"FENCE 4e, IG'ElIF YARD S'TrA,^k FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) �H C FOUNDATION (2ND) t� ROUGH FRAMING& ,y PLUMBING 1 Mme. INSULATION PER N.Y-. ►-] STATE ENERGY CODE G r FINAL ADDITIONAL COMMENTS t � cal. , --j o rz d 'PS T&Vg--..& SOUTHOI D BUILDING PERMIT APPLICATION CIECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWNMALL Board of Health SOUTHOLD,NY 11971_ 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (0 31)765-9502 Survey. Southoldtownny.gov PERMIT NO.— Check Septic Form N.Y.S.D.E.C. Trustees �� ,.,�� � C.O.Application S � �-•-':S f�..��",.�� -"`!!!J Flood Permit 20 Examined,.-3 l Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved 20 R w.,�.. Mail :Elizabeth Rexrode ray<_.. . Disapproved a/c Rexrode Chingos Architects Phone: 212 387 7980 Expiration 20 B ' ding spector : `J APPLICATION FOR BUILDING PEIIIV6 - D LI/ SEP 3 .2020 . Date ,20 INSTRUCTIONS IG.DEFT. a. i be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of� ;lab orate p Ent scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways: c.The work covered by this.application may not be commenced before issuance of Building Permit. d.Upon approval of this application;the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work: e.No building shall be occupied or used;iii whole or in part for any purpose what so ever until the.Building Inspector issues a-Certificate"of Occupancy. . f.Everybuilding.permit°shall`expire if the*work authorized has not commenced within 12 months after the date of issuance or.has not been completed within.'l8-montiis from such date.If no zoning amendments or other regulations affecting the property havebeen enacted in the inteiim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months:Thereafter,.a new::perimt..,shall be;regwred. APPLICATION:IS HEREBY 1MADE to;the Building Department for the.issuance of a Building Permit pursuant to the Building Zone Ordinance bf the Tm�v o"Sotfil8 Sffo3l ;County,New York,and other applicable Laws,Ordinances or Regulations,for the cons etinn-bf t5i61d* tt b. yr aittrjratioiis or for removal or demolition.as herein described.The applicant agrees to comply with all applicable laws,ordinances,Building code,housing code, and regulations,and to admit authorized inspectors'on premises and iri'buildiiga;foriecessary.inspections. .. • i (Signature of applicant or name;if a corporation) Elizabeth Rexrode, Rexrode Chirigos Architects 10 e.23rd sf NY,`.NY`'`:6010 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Architect Name of owner of premises . Orient ReaftX,it1c r r ' (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer Ivy Crewdson, member (Name and title of corporate officer) Builders License No. to be determined Plumbers License No. to be determined Electricians License'No. to be determined Other Trade's License No. 1. Location of land on which proposed work will be done:: 675 Skippers Lane Orient Village House Number: Street Hamlet County Tax Map No. 1000 Section 2 4 Block 2 Lot 1 FSub&—sion Filed Map No. Lot, 2. State existing use and occupancy of"premises and intended use and occupancy of proposed construction: a. Existing use and occupancy_single family residence b. Intended use.and occupancy single family residence 3. Nature of.work(check which applicable):New Building Addition_ Al te anon_ Repair Removal Demolition Other Work e-n tk2 (Description) 4., Estimated Cost $400,000 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units 1 Number of dwelling units on each floor n/a If garage, number of cars . 2'. 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. n/a 7. Dimensions of existing structures,if.any:Front 40:5'. . Rear 40.4' Depth 32.2' Height 22' Number of Stories 2 Dimensions of same structure with alterations or additions: Front Rear Depth Height " 22' Number of Stories 2 8. Dimensions of entire new construction:Front 57' Rear 57' Depth 32.2' Height 22'. Number.of Stories .2 9. Size of lot:Front 104.66' Rear . 103:14' Depth 135.22' /133.33'.. 10. Date of Purchase August 13,2020 Name of Former Owner Marcelo Ismael Ballve&Sara Silvina Chavarri Ballve 11. Zone or use'district in which premises are'-situated Orient Village 12. Does proposed construction violate aay zoning law, ordinance or regulation?YES NO x 13. Will.lot be re-graded?YES NO X Will excess fifl be removed from premises?YES NO X 61}69�ierrepont#51, 14.Names of Owner of premises"Orient Realty LLC Address'Brooklvn,Nx 11201, . Phone No. 917 337 9027 Name of Architect Rexrode.Chingos Architects Address 10 E23rd st,NY, NY 10010 Phone No 212387-7980 Name of Contractor to pe-deterrriined Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater.wetland? *YES NO x * IF YES, SOUTHOLD TOWN TRUSTEES-&D.E.C. PERNHTS MAY BE REQUIRED. b. Is this property within 300 feet of a tidai�wetland? * YES x NO * IF YES,D.E.C. PERMITS MAY BE.REQUIRED: 16. Provide survey, to scale,with accurate.foundation plan.and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to'this property? *YES NO x ' * IF YES,PROVIDE A COPY: STATE OF NEW YORK) SS: i COUNTY OFi . Elizabeth Rexrode being duly sworn,deposes and.says that.(s)he is the applicant (Name of individual signing contract)above named,. (S)He is the Architect (Contractor;Agent, Corporate Officer,etc.) int of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;.andjthat the work will be performed in the manner set forth in the application filed therewith. Jessica L Thomas Votary pdblIc,State of New York Sworn to before me this Na 01TH6 y S37 � a day of 20 rc ' W., Cglumbbis Coubty) Term.Exkes July gnature o Notary Public i oy�gUFFO�,�- � Edward Webb,.Chairperson 4 Town Hall Annex � : : Anne Surchin,Vice.,Chair, ,. !ll41. y`a4' , ',., :.; 54375.RouteY25 Robert 41arper PQ::$ox„l 1.79. Joseph McCarthy Southold,NY.11971 1Vlariella Ostroski Fax-(63l).705-95..0 Tracey Dwyer,Administrative Assistant ''Te1'eph�oft6:�'(63.1):'765�-18(.2 www.southoldtownny.gov` Town of Southold Historic b Coh missioli¢ . Octobf 'P;2020 OUIQN# ;0:282`02 certificate.or' pXonriafeness.. RE: • 675 Skippers Lane,Orient,i—S”, 1.000-24:-2=1 Owner: . Orient Realty LLC RESOLUTION.' WHERXAS; 675:Skippers Lane;Orient;NY:is ori:tbWfflown.of Sbuttiold'�egistry i f Historic: :. Landmarks,and WHEREAS, as set forth in Section 56.-7.(b).of the Town Law(Landmarks Preservation±Code) of the Town of Southold, all proposals�for material:'change/alteration must be_ reviewed and granted a Certificate off Appropriateness by. Southold Town::. Historic Preservation Commission prior'to the issuance of a.Building Permit,. and, WHEREAS, the applicants architect Elizabeth Rexrode submitted a proposal outlining-the scope of work,which included'the construction of a 443 sq.. ft. screened porch addition andto construct a 25.0 sq,ft.rear deck addition and the replacement of windows, doors,roof shingles,,cedar siding shingles,porch columns and additional details to the existing single family dwelling as applied for,.as well as replacing windows;-a door,cedar"siding shingles,roof shingles,gutters and downspout to the existing accessory garage as applied for, and, WHEREAS, the architect presented commissioners with an outline of the project during a pre- submission conference on September 29,2020, and, WHEREAS, a public hearing was held on October 29,2020,where the applicants and their architect submitted final drawings.of the scope of work and outlined the project for the commission; and, T BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness. MOVER: Commissioner Harper SECONDER: Commissioner Ostroski AYES: Surchin,Harper,McCarthy and Ostroski RESULT: Passed Please note that any deviation from the approved plans referenced above may require further. re.view from the commission. Signed.: Tracey L.Dwyer, pplication Coordinator for.tbe Historic Preservation Commission Dato; October 30,2020 �p wo •� �k, ... >: . `�•�>..•• "• ...•:.' � INGDEPARTM CC. NT: ::Elecrical°Iror HOLDng2O TO1 -OF SDUT z - OX 1:179:: wn Ha Annexe 54375 IVlain Road- RQ B-� w jK(; ut( o(d (Vev�i Yior 117'(• 959 : �. O:FH�phdhe:( 31) MATSd2:- FA C::(631j:7G5=g5Q2 ... r : _ �x : . . .:..: y:�. auth4.l (fi�wfi&` 6,.:__ ea tl soi # Q1d oa n i. .. ori:: .1 I { NT OR:E:LECTRICAL:INSPECTI: 1` is •--.....:e — —— —__—•____ ... •-- .... ,: .v?..vim..^'r .. ..'•' _ — E F R-1CIAN I MAT-ION-oil:16w—ria6on ftecjiiit d� 1 Oompany:Na': e-)-PZ--(QX�Ppc)i - - - _ - 1arri ticn$e:N : -1 p • - - -- - I?I7p11e hIB:: f :JOA. SITE jw", O MATION -(All:info€m yin Regui dl Nrf1f; . 1t dress. - - - -- - Gr-& -S io. .: . Fah e --- - - I�at.-... -- - _ i 'T 01`I : ' t OAKIPILe . :r Is job ready for inspection?: >�i0 Ro gh:`In fife :Da you feed b:Terri: Certifr�ate?: Y : 1 NO` : p Iss . Temp-lnformatl'd ' (Ali-iiafbr-ma iorr:regr,ired Service Siz.. 1 Ph) 9 Ph ize A: . #Nldteis:.._____....J..._ _41d- .... 1VewServie:» dire:Recar�net=Flvad Ft anrect-Service:Recorinecteci :Under:.graGri. Oizeread #f --tl La#eral;.: 1 2- H Fra.:..:. :.:Pali:..........:_,IEll. r{�done.on Setvuce� N ' �tit� ---._....... _........._.._ .............._..._._:...�._..-._._....._ ......... A„ti..._.:>nel rnformaton , - _ _ _ --- PAYMENT.:D,U:E...W-1 T.H..APPLLCATIO:N. RegU6.,M:for 1.6§poai6n F.oim:xls �G , <Z,� �� 1c, r APPROVED AS NO(T�ED DATE:-3)),5/19) FEE: - �. NOTIFY BUILDING ARTMENT AT OCCUPANCY OR 765-1802 8 AM TC =E PM FOR THE FOLLOWING INSPECTIONS: USE IS UNLAWFUL 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE WITHOUT CERTIFICATE: 2. ROUGH - FRr1h✓9iPdG .& PLUMBING OF OCCUPANCY 3. INSULATION 4. FINAL - CONS; MUST BE COMPLETE. >. ALL CONSTRUCTION, :;HALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE, COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF ,., H91-9 TNI ens muni n TOM p{_AW BOARC S09T40w`-TreV&qRUSTEES ELECTRICAL INSPECTION REQUIRED 9 q fgt KOHLER. ��:6� J m Models. 2 L. - multi-Fuel LPG/Natural Gas 09001 - Standard Features 4 , * RDM Controller NATIONALLY RI:09CUta ca One digital controller manages both the generator stet and transfer switchfunclions(with optional Model RXT). o Electronic speed control responds tlir€skty to varying x tea; demand. •w a ®nCue Plus Generator Management S � g yarn for.remote nmoriitoring is included wilt trite generator. ;Y e Koehler Command PRO Engine Features ' o Kohler Command PRO5'OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustingnt or lengthy break-in requirements. Designed for Easy Installation o Sturdy aluminum base can be mounted on gravel or a ncrete mounting pad. o Fuel'and electrical connections through the enclosure wall The Kohler*Advantage eliminateahe need for stub-ups through 1he base. D Customerconneotion terminal block located nearthe High Quality Povmr controller allows easy access for field wiring. Kohler home generators provide advanced voltage and o Designed for outdoor installation only. frequency regulation along with ultra-low levels of harmonic distortion for,excellent generator power qualify to ' Certifications protect your valuable electronics. a Neets emission regulations for U.S.Environmental Protection Agency(EPA)with both natural gas and LPG. 9 Extraordinary Reliability a UL 2=/WL listed(60 Hz model). Kohler is known for extraordinary reliability and o GSA certification available(60 Hz model). performance and backs that up with a premium 5-year or o Accepted by the Pvt�tssacYius�s Board of Registratiari of 2000 hour limited warranty. Plumbers and:Gas F'rtiers. s Powerful Performance ca Meets 181 mph wind rating. Exclusive Rowerboost— technology provides.excellent starting power.§ • Approved for stationary standby applications in locations served by a reliable utility source. Aluminum Enclosure . 20RCAL models packaged with a Model RXT autdmatic a Attractive aluminum,enclosure allows installation as class as 18 inches from your home or small business_' tm r=r switch are available. See page 4 and the Model RX r ATS specification sheet a Enclosure panels can be removed without tools to allow easy:access fo(maintenance and service. a 11 wranty o 5-year/200D hour limited warranty for on-grid(standby)_ appiications in locations served by a reliable utility source. Generator Ratings Standby Ratings Lime Circuit Nattiral Gas LPG Breaker ,Alterna r tVo tage Phase Ha kWlttlfA Amps ld,R►AMA AnTs Amps Poles 2F7 1201240 1 60 Isiis 75 2= 89 100 2 1201208 3 60 17121 56 17121 5s 70 3 207 1201240 3. 60 17121 51 17121 51 60 3 2711450 3 60 17121 26 17121 26 30 3 Note: -Me line circuit breaker is automatically seta:cted bassad on the generator set nvdel and Voltage configurl&an. RATINGS:StatdhyratirgsapPt�toinatallatzat3asty[adhyaeer uUilyso�aw.Aftigle.pias.aanitnamratedffitA3powerfcctoyTnestannyratingaverage toad root¢or 80t'.tic Uca duration est the pawea oeatage.h'a�ertaFtd calu'r�Y'Ea ripecHkad at this reGstg.Ra6ags are rn aacaxt mea with ISO.309Qrt r1S5.*at4,AS'L'99,and[]idr 52Ft:CiEAt[�n,AL GUMUNESFOR DERATING:A[.717UaJE_09064%, per305m(10008.)o$mg4onahove159m(Mfuj.'rEWE€LATUAE:acre2%par 6.54G(10°F)trnprraturo Icsoasseffiaae1dd'Cfit@-Fj. Avaiahiriy 4,:aapJr�taacharagew:hec7tmotk®.7laegen�alarsatc>sa�wratwuuror r.^.aen+estho rl�htto char*go t3tcl deagrt ar e�irx�al�rswthaastnatfaran3w�hautany abr�atlon ociabriiytvtratsaeuer_ Qanlrctyaur local KoblerCo6l gematar dsttibutar forays Why, § ChecktheaappllamxmznurqCtarot'spaworrequlreamers.Consult aKWierrnPowersviiamsprofesricoaltoc�vculotryour aoctrusiderttlelpaomr'sys,emregulremew*r. ? Meal.NFFAa6doWesfor 18knitofemancetocambusbM6maatedaL%Qftcks=o and local aodcsforml6mumdis4.cverequIredfromasinm1iire. 04.272(20RcN 9119: Alternator Specifications Aftemator Specifications Alternator Features Specifications Alternator a Compliance AVAh NEMA,IEEE,and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Field a Self-ventilated and dripproof construction. Leads,quantky 2F7 4 * Windings are.vacuum-impregnated with epoxy varnish for 2G7 12 dependability and long life. Voltage regulator Digit;al * Superior voltage waveform and minimum harmonic Insulation: NF_VA MG1-1.66 distortion from skewed,alternatcr construction. Material Class H * Digital voltage regulator with A1.0%no-load to full-load Temperature rise 130'C Standby RMS regulation. Bearing*quantin,type 1.sealed * Rotating-field alternator with static exciter for excellent Coupring Direct load response: Amortisseurwindings Nit * Total harmonic distortion(THD)from no load to'Jull load with voltage regulation,no-load to full-load RMS —_1.0% a linear load Is less than 5%_ One,,step load acceptance. 10W.of Rating Peak motor start M kVA: (35%dip for voltages below) 240 V,1 ph 2F7(4 IwQ 41(tD H4 240 or,48D V,3 ph 2G7(12 load) r's(ad H4 Application Data Engine Exhaust Engine Specifications; Exhaust System Manufacturer Kohler Exhaust.temperalum exiting the Engines.model,type CH10004-Cycle enclosuTe at rated W,dry,'C(°F) 260(500) Cylinder arrangement V-2 Lubrication Misplacement,erns(cu.in.) M(61) Lubricating System Bore and stroke,mm(in.) 90x7&6(3.54 x 3.1} Compression ratio 8.81 Type Full Pressure. Main bearings:quantity,type 2,Heavy-Duly Sleeve ON capacity(with filter),L(qt.)§ 1.9(2.0) Bearings Oil tai torr. type 1,Cartridge Rated FIPM ON cooler integral 60 Hz. 8600 § Kohler recommands the use of Kotler Genuine oil and filter's. Max.ongino,po=T at rated rpm,kW(HP) LPG.60 IlAz 23.0(30.9) Fuel Pipe Size Natural gas,60 Hz 202(27.1) Cylinder head material A I[urninum Minimum Gas Pipe Size Recommendation,in.NPT RapeLen4jth, Natural Gas LPG Valvo material Steell8tellit5do M 2811,0130 Stu/hr. 340=Btuthr, Piston typo and material Alumitnum Alloy Crankshaft material Heat Treated.Ductile iron 8 (25) 1 314 Governor"a Electronic is (50) 1 1 Frequency regulation,no load to fug load 1lSDChMft= 1114 1 Frequency regulation,steady state 46(150) 11/4 1114 Air cleaner type Dry 61 (200) 11/4 1114 Engine Electrical Engine Electrical System Ignition system Capacitive Discharge Starter motor rated voltage(DC) 12 Battery(purchased separately); Ground Nogalivo Vdits(113C) 12 Savery quantity 1 Recommended cold cranking amps: (CCA)rating for-1910(01F) 500 Group size 61 &$-272 12ORQe4 aF19c Fuel Requirements RDC2 Controller Features,Continued Fuel System LED Indicators for utility poweir and generator set.source Fuel types Naturat Gas or LPG avallability acid d ATS position(Made]RXT transfer switch Fuel supply inial 1/2 NPT required) Fuel supply pressure,kPa(in.H20): LOD display; Natural gas 0.9-2.7(3-541) o Two lines X-16 characters per line LP 1.7-2.7(7-11) o Backlit display with adjustable contrast for excellent visibility In all'Ilghting conditions Fuel ComoositlainUmits 1� NzL Gas LPG Mothbinei%by volume(minimum) 9D min, • Scrolling system status display, a o Generator set status E thane,%by volume.(mmdrnum) 44 max. o Voltage and frequency Prcipane,,%by volume I.D mm. 85 Hn. Propene.%bA volume(ma)dmumnax- ) 0.1 max. 5.0 ro Engine temperature C-4 and higher,%by'volume MBX, 2.5 max, o Oil pressure Sulfur,ppm mass,(ma)dmurn) 2$max_ o Baths voltage Lower heEWng x0fte, o Engind runtime hours MJW(Btu ),(Minimum) 33.2(BOO) 84.2(22130) * Date and time displays Contact your local distnb=r for suitability and rating derates based * Smart engine cooldown senses engine temperature on fuel compositions outside these limits. * Digital isochronous governor maintains steady-state speed,at Operation Requirements all[dads * Digitalmoltage.rpgulMEw, ±1.0%,RMS no-load to full-toad Fuel Consumption,m311hr.(cfh)L&6QHz '0 Automatic start with programmed cranking cycle %Load Natural Gas LPG & Programmable exerciser can be set to start automatically on 100 8,0 (281), 3.9 (130 arry future day and time,and run every week or every two 75 6,9 (2 43) 3.1 (109) weeks 5D 4.6 (161) 2.3 (82) a Exercise modes: 25 3.6. (127) 1.7 (69) o Unloaded weekly,exercise with complete systern. Exerdso 2.0 ( 1) 1.0 (35) diagnostics Morniinal fuel rating: NaturaJ gas: 37MJ/ms(1W0Btu/tt3) D Unloaded full-speed exercise LPG-, 93 MJ/rn3(25W BtuJft,3) o Loaded full-speed exercise(Model RXT ATS required) LFIG conversion factom. 8.58 ft.3='1 b; * Front-aoc*ss mhl USS connector for SitbTech' or USB 0.535 m3-1 kg Utility connection 36,39 ft3 =1 gal. a Integral Ethernet connector for Kohler&OnCue@ Plus Generator Set Sound Data a Built-in 2Z amp battery charger * Remote two-wire start/stop capability for optional connection Model 20RCA 8 point logarithmic average,sound lev4ls'are of a Model RDT transfer switch 64 dB(A),during,weekly engine exercise and 69dB(A)during a Diagniostlamessages. Displays diagnostic messages for the full-speed generator diagpoffics.and normal operation,.* engine,generator,Model RXT transfer switch,programmable All sound.levels are measured.at'T meters with no,load, initerface module(PIM),and load management d&vfce. Lowest of 8 onts measured amund the generator. Soun�d levels at Maintenance reminders ,other points around generator may vary depending on Installation is System settings: paramos. o System voltage,frequency,and phase RDC2 Controller o Voltage adjustment o Measurement.system,English or metric 0 ATS status(Model RXTATS required), n Source availability ggw— o ATS position (normalArtility or emergencylgenerator) o Source voltage and frequency ATS control(Model RXT ATS required): 0 Source vokajeand frequency settings 0 Engine start time delay o Transfer time delays o Voltage calibrifich The RDC2 controller provides integrated control for the o Fixed pickup and dropout settings generator'set Kohlerc Model RXT transfer switch, e Progromr�able Interface Module(PIM)status displays- programmable interface module.(PIM),and load shed Idt. 0 Input status(activefinactive) RDC2 Controller Features o Output status(aclivelinactive) * Load control menus, o Membrane keypad: o Load status * OFF,AUTO;and RUN pushbuttons o Test function * Select and arrow buttons for access to system configuration and adjustment menus a LED Indicators for OFF,AUTO,and RUN modes Gam WFIGA)911190 KOHLER CO-,Kohler,W=nsin 63044 USA Frnolfe%10-457-4441,Fax 920-459-1646 mwHLER. ror thenearestMes and servim outlet in tho us and Canada,phone 1-600-W-2444 KOHLERPnvvencom Generator Set Standard Features AuLmnadc Transfer Switches and Accessories • Battery cables ij Model RDTATS • EPA,certified fuel system U Model FIXT ATS • Aluminum.sound enclosure Model RXT ATS with combined interfai*, load • Critical silencer management board • Field-connection terminal block Lead shed ki0:for RXT or RDT Power relay modules(use up to 4 relay modules for • Fuel solenoid valve and secondary regulator eabb load management device) • Line circuit breaker Ll Other KohlerO ATS • Muld-fuel system,LIPC-driatural gas,field-converfible 20RCAL Mode]Packages • Oil drain extension win shutoff valve Ll 20RCAt,with'I GO amp RXT with I 6-.space load centet and • OnCuelb Plus Geheratbr Management System NEMA I steel enclosure for Indoor installation • Premium 5-year limited warranty Lj 20FICAL with 200 amp service entrance-rated Model FIXT • RDC2 generator selVATS controller with combined interface/lead management board and • Rodent-resistant Construction corrosion-resistant NFMA 311 aluminum enclosure • Sound-deadening,flame-retardant foam per IJL�94, Warranty class HF-I L] 5-Fear Comprehens-we Limited Vftrranty Available Options Q I0-Year Cemprehensive Limited Warranty Approvals and Listings L) CSA approval Concrete Mounting Pads • Concrete mcunting,pad,31n.thick • Concrete mounting pad,4 En.thick (recommended for storm-prone areas) Electrical Accessories (3 Battery L] Battery heater,r 120VAG E3 Battery beater,240VAC La Cold weather package,'1 2DVAC Generator Set Dimensions and Weights L3 Cold weather package,240VAC E] Emergency stop kit Generator SW Size.L x,W x H; (47 x 26.2 x 32,2 in.) * PowerSjhoO Automatic Paralleling Module(APM) shippiry Weights; (single phaselonly;parallel two 2OkW residential generator- 20RGA Generator Set,, 252 kS(K5 lb,) sets with the RDC2 controller) 20RCAL witih 100 A RXT ATS wjLQ 277 kg 6611 lbs.) * Programmable 1n1erMK*module(PIM) 20RGAL with 200 A RXT SE ATS: 272 kg(00 1b.) (provides 2 digital inputs and 6 relay outputs) i, L Fuel Systeiiiii Accessories L3 Flexible fuet'llne(included on Q$models) C3 Parburefor he'ater,120 VAC L3 Carburetor heater,240 VAC H CarWretor'heater isiecommended,for reliable starting at temperatures below 0,a 6(820F) Literature Q General maintenance lfteradure kit. Ll Overhaul literature kit NMIL, prwheed for m&==cmly am&'ojed nm be used w gmuong Production literature kit InsWULIm. ma�adrrmpzd Maintenance DISTRIBUTED BY": L ) Maintenance kit(includes air filter,oil,oil,filterr,and spark plugs) D 2GIa.2019 by MID&CtL AJI rhn,L-.rewmed, 64Q72(nRCA),9119c CRI ' V38 (o � G� DI� �IC� C 079 � C�OppC� G3� �aG� C� Q) nUFFHU0 MW 09T ARCHITECT: REXRODE CHIRIGOS ARCHITECTS 10 EAST 23RD STREET, 6TH FLOOR NEW YORK, NY 10010 � TEL: 212 387 7980 DRAWING LIST: ARCHITECTURAL C . 1 :ZGARAG:E E T.01SURVEY.01SIT TE PLA A- 2 .00GENERAL NOTES A-050. 1 G R G PLA S � A-200.01 GARAGE EXTERIOR ELEVATIONS N-W A-201.01 AG EXT R OR E EVA I N -E A-300.00 GARAGE EXTERIOR DETAILS & SCHEDULES A-301 .00 DOOR & WINDOW TYPES, DETAILS --------------- THIS APPLICATION IS A SUPPLEMW N��'O EXISTING P�Zell" ED o � dm N.2siz� DEPARTMENT OF BUILDINGS 11 . 30 . 2020 DEPARTMENT OF BUILDINGS 03 . 03 . 2021 1,,, - 3 X021 RENOVATION OF: ------ -- - _- - - -- - __ CREW DSO N , 1 , , ed IDE RE , S NE , C d' 1 3' zu i t a a' EC LOT COVERAGE t' P 1y A>a q• Y F i - �w, 1 4 ,k- '1• a� 7 �i. >r - w �-f�� • Y r yr l 40 �P. 13 •n ,r1 $ 3 i fr} 3 1 ,1 - 'SVR E i EXISTING LOT COVERAGE PROPOSED LOT COVERAGE PR OPE R Y , - 675SKIPPERS I P PER S A N E T 1 Sp •P T AREA— 13 817 S FT 0 — LO A LOT AREA 13817 fT Q S Q - .r, h,? J' _ 7 T� O I RIE N } r - } 4 , d i t b" . i •g. j. �i — FT } 3 (STING HOUSE 1 302 S EXISTING HOUSE- S ,' EX Q G H SE 302 Q FT , q RI ,',• d O ENT -0§� , NY 1 1 ,5, " 957 0.. s , / D ISDU # 'UTHOLD ., — .� H L GARAGE- 373 S FT IN EXISTINGE Q EXISTING 373 SQ FT I d — 209 PORCHES— 303 S FT t - EXISTINGHES- EXISTING PORCHES- S Q PO C ES Q d } 4 Y' q?, Z� •3 -i s 1'! YY J J.. 1 i �C) _ ,' c� tl ,�'D _ ,3, LK, C`0 �11N T.Y DRIVEWAY 78 S PR P S , EXISTING5 F? 0 0 ED ORC ES 628 �; :,N P H S Q 4 Q •J �3 , w Y^z �";ro y ^L,r t 't ro '»Yn t. .d '+4 {. ,"i , rt :rY"a,i. rjr k SIDEW LK 89 5 ROP RA 0 ! t v EXISTINGA FT PROPOSED TERRACE 25 S Q Y a !. FT d i , _ 1, ,� �e,,' — .100 0 2 }f �; 4-02 a,. ,' 01 r. S TOTAL TOTAL FT— 2 645 S Ff OT L S FT 76 S Fi I .,. 2 2 Q Q Q Q .p f ' ARCHITECT: , •,. '3 - zr�Y r N 7 SC — ;1 i ALE.• .� 1 20 2,645/13,817= 19.14% 2,762/13,817= 20% i' -1° "i I » V 4' 'r. 201 SEPEMBER 11 , � RE XROD C HI RIG OS ARCHITECTS ECTS i 4 .•A fY.- ,r k r 'l d a 1,. a '3 MA Y 8 2 , 018 >, { }i 8 I , _ 4 TORE I C R ..1 20 20 0 C. E L`0 T-COVERA G E d r °1 ,f �1 , 2 - - I 'i ao r7,• d k f s 4 1 > r t Ff: 'f= 'b �?t. A: i F- - G' °F _ 10 I EAST 3RD S T. 6THFLOOR LOO } ! :)L yi r x :7 v 4" •i- Y d "arf a' J$. NEW YORK, NEW YORK 10010 ak--" ., 9° <J 1 ' T 2 12 38 79 a 7 80 , F21 h' 2 260 a 2794 i /x •s i' e� d' D' CP _ y^le p } 1 - S-. ' {S } r 'sa.r' ` yam5 J• .. , 'JsAr, ; , s •'J STRUCTURAL ENGINEER: V OVER- 150 DWELLING M M }} - t' `yt c5 ,r F/ 1, z .r' z, s� j�4 a. h 1 F. i n.r 1 •.{r' ss-`.qtr.;� -�:' w :,R �� :�� �•.. _ �.�` '��> :.�' ��,_, a J �= R BLD .r'::: ' � :�4-� _ EVAN AKS EL AD ., a , l p's> r , a t 1 _ F: WE L. t' �Si 1X RE L" t A A , , "ea t�y i - i -r 4 5' f P `t'1 -I sti h >2 1 W- n I I x, �r , yyJr > 1: s •r 1 t -v 1 - t; U �. 1 S.� AY STREET, F L 3 4' ! .=�• s: , .� — �u. NEW YORK, NEW W YOR K 10013 -S Y s> .c- F B , , 17� T 9 689 0301 EL 1 G' `�aw I , , t :h i a a L, 1 i , F i '9 d 9 - i' 1 n , ISSUED TO OR DATE r' , h •J: >q, r{ t , y } 1 i ja 11 �y pp i b t'. r a' x ! } r' t DOB L HPC N , 10 .16.20 DWEL I G ,1 t 1 °n} I 9` :.i GUNKNOWN - ,•, DOB 1 03. 03.20 , 21 t 1 EL i ^4- nn t. A,. , V 3• � • I , T WELL P `P l +� K DWELLING WELL _ - •�� �r EL{ Li•s:., : G OVER .I 50 :. { , . � ,. �i -4+Iia, +, • . ¢QTR• + r '�Vt, J NOTE. WAuc y J TO HE A� STING WELL !N BASEMENT TO BE r EXI a MOVE- RE , P v FREE r°Pwq�- ;a` ;'�, EL ,10.0XISM ' TEST WELL <lry h, a . - 3 # •!ISI ''I, '+.Nil,yr PAI 14 9 O - 4` i •J `dY L .A- . 'Y �•." pL- y �a� t TREE l , Q - h \ - .T , a� y { I � EXISTING WELL IN BASEMENT i ,I J ✓�3`e , Y i .9 O 2?' .I, Q NEW BALCONY O ® WELL i k COVERED •� Y a EL !! p PORCH o ( . Ro 1 G C a. EL 9.4 R P I m a:_ i l AA $' KEY K - t, t > a'Ikl a• - SC3 - C , � � x l t Yi ••de" t' 0 Q1' R fr I 0 S `w > •^r• d ''s s RE } P 3 , .4 J O BAR k { v :v,,s 3� Y♦J„ a 4�y S A I.n {° y` I,h. G :4^r _ I C C 'r 3 LL :,sh Eo WE ® lt7 A - , p y Y-- F 'Il C ,a 7 I J I V iR•• 5 'a , / a P °i• ',arm �j 1 W A N - c HOLE � 9 ;a TEST 9 s i ) °t F �Pr Y- Y - AKE r 1 ST 0 o z: 0 - i' 47 , f 1.= { u ✓' ® t' N i� I fi, PIPE c „_.. t ,1+ a GL O Y r'r 15 N t N '.COC ,Co R i:. e S T� ,�i / t� c ro •J1:Y"'d, \�V �a 1�S i 1 V +t'V 0 M0NUMEN T f r , WELLI NG fO � , u Y D -B .,l i , V2- s , No 0 - -261 FLAG 29 F- P•s 4 l R - gg N NunLlrY POLE a i a, N f= HYDRANTO NEW 3 S� w .� !- 1 m ;.' g T. S' VA7/0NS REFERENCED TO NAW 88 �c DRAWING TITLE r -4 1 t v" 3+ , d ! t a L 9• .� C E a� ^ 7•.q . N r •J ''I 4 AND CONSTRU N F i V 4' OVAL A CTIo 0 l �•:� S FOR APPROVAL r with he STANDARD $ .s o Ilia w t , om f m � a 6` y '4' t r' s FAMILYRESIDENCES S/NGLE MS FOR YSTF �+UBSURFACE SEWAGE DISPOSALS .j �7 i *I t y 'v and on h e It � herein a rm to l b/de b the condttlons set forth t d wIl a � 4 3' :! 'r :•t mss. a= , , SURrRVEY e eon 1° .�' shown h are from �..r.' ,r'• _ cesspools _ f 1 n ell and ce o , e ocot o of wells tract. 7h ! s �+� c 0 n 'a P ' j j W: 4 b' '] :r field observations and or from data obto/nedfrom others. . .� d :1 1' ff \, h�d y r, r' s,= V a 4 �sL i' t Ia :{ rJ. VIOLA 0 S A TI N OF SECTION 20 F THE A ON OR ADD/TION TO THiS SURVEY I 7 90 ANY ALT E'R n ' 4 - °r. E 1 U 8� - O G .� EYOC2 0 to E SECT1 N 7209 SUBDI l0 L AS VIS N2. AL N W. EXCEPT A , DUCA 110 LA ?, a STATF f YORK NEW x,. s 631 D COPE F Al 7 P AN S 7HERE0 ONLY lF SAID i 1 65-5 TH/S MA 020�F X' RE VALID FOR A 631 -1� S HEREON A L •� ) ••'787��''. FlCATION ) ER ''s a t�i<r 3..�, ' ql` !y, x�t n +:> •i A`_— VIII rI�7 �f'� ARE V • '1 E SURVEYOR WHOSE S/GNA7U E "f° F 7H R P SEAL 0 - R IMPRESSED S COPIES BEA THE OR i - MA & O . ,130 '?.. X90 P P PY - ro .'4 2 5. d ti R' HEREON. " EARS HE PP A a= ,•� 23 7 0 RA L E ER'� V EET�' u, r' 1 11 �ST 4� `1 'l? >• .,," , t , , •� a d� � �SOl1TH HOLD, N.Y.-N.Y.• : tt ,•'8,t'; ,5 :R. 1. ? �k t J , 4i I, h ,k i },a xx s i 'tiSw •'.x 1r t a= J ^,I } •r' a j `i max. n! -aR 3� r 4, 1 SURVEY S 0 0 0 0 1 SCALE: 1 r# = 20'-0rr DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS RENOVATION OF: CREWDSON SKIPPERS LANE RESIDENCE 675 SKIPPERS LANE ORIENT, NY 11957 EX'G CONCRETE SIDEWALK ARCHITECT: 13525 REXRODE CHIRIGOS ARCHITECTS Y NEW UNDERGROUND Q I ELECTRIC FENCE 9 I o EX'G TEST WELL 10 EAST 23RD ST., 6TH FLOOR ! o ! o NEW YORK, NEW YORK 10010 N " T 212 387 7980 F 212 260 2794 I N � ! X W C) STRUCTURAL ENGINEER: I 10.46 32.1' 1 M ! EVAN AKSELRAD 40.4' 9 -0 EX'G ASPHALT ! DRIVEWAY i I N BALCONY COVERED ! 16 JAY STREET, IFL 3 SLOPE , SLOPE P CH NEW YORK, NEW YORK 10013 I i ! T 917 689 0301 w o 5.7' C) RELOCATED � I � _-�`_ ELECTRIC METER ISSUED TO FOR DATE o � — i35' FRONT YARD SETBACK _ — o z < ( LOPE SLOPE 10.16.20 EM GENCY 0 I GENER OR I z Z� DOB/HPC REVISION 1 03.03.21 co I M+ EX'G GARAGE I TO R MAIN '� ! SPLIT SYSTEM N HVAC I I ! CONDENSgRS I LANDSCAPE N SLOPE SLOPE o l ~\� I I d SCREENIN HVAC ( I I 0 EX'G SPLIT I ! � I RAIL FENCE I Y \ U e I ! SLOPE SLOPE r ! I \ NEW SCREENED IN PORCH ADDITION Of \A, I I _CD CIO LEX'GQ � FLAGPOLE I l t I NEW UNDERGROUND \ NEW BLUESTONE PAVING o IELECTRIC FENCE Z�Ap���l °O RED Ale Cyf rloo OF F� \ 27.72' 10' SIDE YARD SETBACK I \ I DRAWING TITLE EX'G SPLIT RAIL FENCE N 64'45'40'W \ 133.33' SITE PLAN \ EXISTING LOT COVERAGE PROPOSED LOT COVERAGE LOT AREA- 13,817 SQ FT LOT AREA- 13,817 SO FT \ EXISTING HOUSE- 1,302 SO FT EXISTING HOUSE- 1,302 SO FT EXISTING GARAGE- 373 SO FT EXISTING GARAGE- 373 SQ FT OYSTER PONDS HISTORICAL SOCIETY EXISTING PORCHES- 303 SQ FT EXISTING PORCHES- 209 SQ FT EXISTING DRIVEWAY- 578 SO FT PROPOSED PORCHES- 628 SO FT EXISTING SIDEWALK- 89 SQ FT PROPOSED TERRACE- 250 SO FT TOTAL SQ FT= 2,645 SQ FT TOTAL SQ FT= 2,762 SQ FT cl SITE PLAN 2,645/13,817= 19.14% 2,762/13,817= 20% SCALE: 1/8" = 1'-0" w A- 0 0 . 01 ol DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS RENOVATION OF: CREWDSON RESIDENCE 675 SKIPPERS LANE ORIENT, NY 11957 ARCHITECT: REXRODE CHIRIGOS ARCHITECTS 10 EAST 23RD ST., 6TH FLOOR NEW YORK, NEW YORK 10010 T 212 387 7980 F 212 260 2794 STRUCTURAL ENGINEER: EVAN AKSELRAD ELEC. METER 2,4 REMOVE EX'G A201 WINDOWS FOR 301D NEW INSTALL OF NEW WINDOW 16 JAY STREET, FL 3 o.S.C> NEW YORK, NEW YORK 10013 T 917 689 0301 NEW HOSE BIB ISSUED TO FOR DATE DOB 1 1 .30.2020 301 GARAGE1� DOB/HPC REVISION 1 03.03.21 REMOVE EX'G14'-6" 301 DOOR FOR NEW DOOR INSTALL OF NEW 1,3 301 GARAGE 1 3 RIDGE EX'G A200 A201 w BEAM GARAGE DOORS TO REMAINNEW N EW WINDOW WALL 8 -$ SCONCE / EX'G REMOVE EX'G III 301C CROSS f- WINDOWS FOR III INSTALL OF NEW - - - - BEAMS i NEW WINDOWS ROOFLINE ABOVE 301A 3018 NEW PENDANT I / LINE OF DRIVEWAY - 1 & SWITCHS / WINDOWS FOR \ J INSTALL OF NEW CL WINDOW JCL WINDOW ~ \\ �LANDSC PE � \ '-,,,. SCREEN NG @HVAC HVA ON�DENSERS, TYP 2 ...x..32'` 29" H GENERATOR 47" x 26" x 29" H A200 C,)�GAR AGE DEMO PLAN 2 GARAGE PLAN �j GARAGE RCP SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" DRAWING TITLE 11-1 GXED PPLAN & CEI a A- 050 . 01 ol DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS RENOVATION OF: CREWDSON RIDGE RIDGE RESIDENCE EL. 15'-1 1/2" EL, 15'-1 1/2" B.O. BEAM B.C. BEAM 6 75 SKIPPERS LANE EL. 14'-6" EL. 14'-6" ORIENT, NY 11957 REMOVE EX'G ROOF SHINGLES FOR INSTALL OF ARCHITECT: REMOVE EX'G NEW CEDAR SHINGLES FOR INSTALL OF FOR CHIRIGOS ARCHITECTS NEW B.O. BEAM B.O. BEAM _ EL. 8'-0" EL. 8'-0" 10 EAST 23RD ST., 6TH FLOOR NEW YORK, NEW YORK 10010 REMOVE EX'G T 212 387 7980 F 212 260 2794 CEDAR SHINGLES FOR INSTALL OF EX'G GARAGE NEW DOORS TO REMOVE EX'G STRUCTURAL ENGINEER: REMAIN WINDOW FOR INSTALL OF NEW EVAN AKSELRAD 16 JAY STREET, IFL 3 NEW YORK, NEW YORK 10013 FINISH FLOOR FINISH FLOOR T 917 689 0301 EL. o'-O" EL. o' o" ISSUED TO FOR DATE (D EXISTING EXTERIOR ELEVATION — WEST DOB 11 .30.2020 EXISTING EXTERIOR ELEVATION — NORTH SCALE: 3/8" — 1'-0" SCALE: 3/8" = 1'-0" AiDOB/HPC 03.03.2021 RIDGE RIDGE EL. 1`i'-1 1/2" EL. 15'-1 1 B.O. BEAM B.O. BEAM EL. 14'-6" EL. 14'-6" NEW EXTERIOR LIGHT FIXTURE 12" 12" 8" 8" PTD FASCIA NEW CEDAR SIDING SHINGLES PTD WD TRIM NEW ROOF B.O. BEAM „ B.O.- BEAM SHINGLES EL. 8'-0" EL. 8'-0" NEW CEDAR I yTI I I I I I I I I I I I I loo� I I SIDING SHINGLES NEW GUTTER & o/ DOWNSPOUT NEW GUTTERS NEW WINDOWS & & DOWNSPOUTS PTD WD TRIM DRAWING TITLE 3 1A TB GA GE EXT OR GENERATOR CONDENSER '° CO N ER EUA IONS FINISH FLOOR FINISH FLOOR EL. o'-o" EL. 0'—O" ��, fr NORTH 8c WEST N SPLIT SYSTEM HVAC CO gENSERS & GENERATOR WITH NDSCAPE SCREEN PROPOSED EXTERIOR ELEVATION — NORTH PROPOSED EXTERIOR ELEVATION — WEST SCALE: 3 8" = 1'—O" SCALE: 3/8" = 1'—O" A- 200 . 01 DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS RENOVATION OF: CREWDSON RESIDENCE RIDGE RIDGE EL. 15'-1 1/2" EL. 15'-1 1/2" B.O. BEAM B.O. BEAM 675 SKIPPERS LANE EL. 14'-6" EL. 14'-6" ORIENT, NY 11957 REMOVE EX'G ROOF SHINGLES ARCHITECT: FOR INSTALL OF NEW REXRODE CHIRIGOS ARCHITECTS B.O. BEAM B.O. BEAM 10 EAST 23RD ST. 6TH FLOOR EL. s'—o" EL. s'—o" NEW YORK, NEW YORK 10010 REMOVE EX'G REMOVE EX'G T 212 387 7980 F 212 260 2794 CEDAR SHINGLES CEDAR SHINGLES FOR INSTALL OF FOR INSTALL OF STRUCTURAL ENGINEER: NEW NEW EVAN AKSELRAD ° 16 JAY STREET, FL 3 NEW YORK, NEW YORK 10013 T 917 689 0301 FINISH FLOOR FINISH FLOOR EL. 0'-0" EL. 0'-0" REMOVE EX'G WINDOW ISSUED TO FOR DATE REMOVE EX'G WINDOW & DOOR FOR JFOR INSTALL OF NEW INSTALL OF NEW DOB 11 .30.2020 Q EXISTING EXTERIOR ELEVATION — EAST ADOB/HPC 03.03.2021 1 EXISTING EXTERIOR ELEVATION — SOUTH SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" RIDGE RIDGE EL. 15'-1 1/2" EL. B.O. BEAM B.O. BEAM EL. 14'-6" EL. 14'-6" 12" 12" NEW ROOF 8" g" SHINGLES PTD FASCIA B.O. BEAM B.O. BEAM EL. 8'-0" EL. 8'-0" NEW WINDOWS NEW WINDOWS WD TRIM & PTD WD TRIM y` NEW GUTTER & NEW CEDAR DRAWING TITLE NEW CEDAR DOWNSPOUT SIDING SHINGLES SIDING SHINGLES3 D G RAG E 1 3 )1C 301 L NEW GUTTER NEW GUTTER \ / D S UT & DOWNSPOUT x I I 1 1 F- 1 T-0�' IONS — SOUT 8c EAST FINISH FLOOR FINISH FLOOR EL. o'-0" NEW HOSE BIB EL. 0'-0" ELEC. METER NEW DOOR & PTD WD TRIM 3 PROPOSED EXTERIOR ELEVATION — SOUTH &IROPOSED EXTERIOR ELEVATION — EAST SCALE: 3/ " = 1'-0" CALE: 3/8" = 1'-0" A- 20 c 01 DRAWING NUMBER: © REXRODE CHIRIGOS ARCHITECTS