Loading...
HomeMy WebLinkAbout48174-Z o�OSUFFat�laG Town of Southold 9/14/2023 P.O.-Box 1179 0 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44549 Date: 9/13/2023 THIS CERTIFIES that the building FIRE REPAIR Location of Property: 2230 Greenway E, Orient SCTM#: 473889 Sec/Block/Lot: 15.-2-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/6/2019 pursuant to which Building Permit No. 48174 dated 8/12/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations(fire damage repair)to an existing single family dwelling as applied for. The certificate is issued to Marshall,Harry&Margaret of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48174 8/29/2023 PLUMBERS CERTIFICATION DATED Auth i ed Signature , SAF oFQF c TOWN OF SOUTHOLD BUILDING DEPARTMENT co TOWN CLERKS OFFICE , . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48174 Date: 8/12/2022 Permission is hereby granted to: Marshall, Harry 215 W 95th St Apt 7L New York, NY 10025 To: alterations (fire damage repair) to an existing single family dwelling as applied for. Replaces 43552. At premises located at: 2230 Greenway E, Orient SCTM # 473889 Sec/Block/Lot# 15.-2-2. Pursuant to application dated 3/16/2019 and approved by the Building Inspector. To expire on 2/11/2024. Fees: PERMIT RENEWAL $215.00 Total: $215.00 Building Inspector TOWN OF SOUTHOLD BUILDING DEPARTMENT j4 Gym y x TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43552 Date: 3/12/2019 Permission is hereby granted to: Marshall, Harry 215 W 95th St Apt 7L New York, NY 10025 To: Alterations (fire damage repair) to an existing single family dwelling as applied for. At premises located at: 2230 Greenway E, Orient SCTM # 473889 Sec/Block/Lot# 15.-2-2 Pursuant to application dated 3/6/2019 and approved by the Building Inspector. To expire on 9/10/2020. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $380.00 CO -ALTERATION TO DWELLING $50.00 Total: $430.00 I 1 1 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. ' B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$:25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. / /(9 New Construction: Old or Pre-existing Building: v (check one) Location of Property: 2.Z3 0 b-Kt�-3 CZ t Et sT House No. (( Street Hamlet Owner or Owners of Property: k mz" "esli ku_ ^ Suffolk County Tax Map No 1000, Section 5 Block Z Lot Z Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: ,V/ (check one) Fee Submitted: Applicane Signature o��OF SO!/j��l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlinCa)_town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Harry Marshall Address: 2230 Greenway E city:Orient st: NY zip: 11957 Building Permit#: 4$174 Section: 15 Block: 2 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service X Commerical Outdoor X 1st Floor X Pool New Renovation 2nd Floor X Hot Tub Addition Surrey X Attic X Garage X INVENTORY Service 1 ph X Heat Duplec Recpt 41 Ceiling Fixtures 13 Bath Exhaust Fan 2 Service 3 ph Hot Water Oil GFCI Recpt 7 Wall Fixtures 2 Smoke Detectors 3 Main Panel 200A A/C Condenser 1 Single Recpt Recessed Fixtures 10 CO Detectors Sub Panel A/C Blower 1 Range Recpt 50A Ceiling Fan 3 Combo Smoke/CO 3 Transfer Switch UC Lights Dryer Recpt 30A Emergency Strobe Heat Detectors Disconnect Switches 24 4'LED Exit Fixtures Sump Pump Other Equipment: Fridge, (2) Mini Fridge, DW, Micro/ Hood, W/D Notes: " AS BUILT NO VISUAL DEFECTS " WHOLE HOUSE RENO Inspector Signature: Date: August 29, 2023 S. Devlin-Cert Electrical Compliance Form a SOUIyo� # TOWN OF SOUTHOLD BUILDING DEPT. `yco 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. I [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE h / 1 INSPECTOR 00 6 re 7 eywo �Of SOl/Ty Y � Y # # TOWN OF SOUTHOLD BUILDING DEPT. `ycou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: aS Reno kt-Frtlat It 14 Ff.T La LJiy , ✓ e-eds 4 A-o Tec6Loj needs A-,o le, 416 41 DATE ��� ' y a 3 INSPECTOR SoUTyO # # TOWN OF SOUTHOLD BUILDIN DEPT. 631-765-1802 , INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: rC DATE 8/Z- 12-3 INSPECTOR g SOGIyo11 * * TOWN OF SOUTHOLD BUILDING DEPT. �o • �o 631.765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: U • -r VIS wod km MAAAe kAlep& c v r � av DATE ZZ INSPECTOR Ql OF SOUTyo� TOWN OF SOUTHOLD BUILDING DEPT. �ycou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ZPR C/O [ ] RENTAL R MARKS: C G� ccsW4�r xv holes 07 I My77V -�7�- n &* A�%A' Dm 45S 1 a rCJS ) 6�!* N-,"';646 . vwa � � fJD ge, fah jo. :6r S DATE INSPECTOR OF SOUTyD� --- - # # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL Q� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] RE C/O [ ] RENTAL REMARK DATE �' 3l Y1l INSPECTOR ENGUNEERi ;NU _ SEP 7 2023 September 6,2023 Bf TLDING DEPT. "I.O��-� 2230 Greenway East Orient, NY Building Inspector Town of Southold Main Road Southold, NY 11971 Re: Marshall Residence-fire damage repairs Dear Sir, I have inspected the framing,insulation and rough plumbing, I certify to the best of my knowledge that they have been constructed and installed in accordance with New York State Building Codes. R 2 0525�� oFESS10�P� BOARD CERTIFIED IN STRUCTURAL ENGINEERING JOSEPH@FIS CHETTI.COM FI SOHETTIENMINEER IN0.COM 63 1 -765-2954 1 725 H O B A R T ROAD S O U T H O L D , N E w YORK 1 1 97 1 FIELD LNSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) .................................... a 'FOUNDATION (2ND-) O ROUGH FRAMING& PLUMBING (�y lT� •• INSULATION PER N.Y. C> y STATE ENERGY CODE Vii W Pi a • n � � -, 3 K vk• 5� 'O/ rYlJs� FINAL Sf 'Dn A.061s y � v rc", vn b i ADDITI NAL COMME S 3-2 7,114- 1 t Z • rn slop • b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST ` BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502Survey Southoldtownny.gov PERMIT NO. f Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application ! Flood Permit Examined 20 Single&Separate Truss Identification Form MAR - 6 2019 Storm-Water Assessment Form Contact: c►1R,b w�dL Approved 20 , Mailto: QAK.S`DR. DisapprovedA. OWNOF►S® i VGues k - PPl 1Litsq Phone: j 2�jZ-(o1p2`� Expiration 20 Building Inspector APPLICATION FOR BUILDING PERMIT. Date FF-6 2-5z4 ,20 15 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signatu a of applicant or name,i0q,corporation) 1 b LQUIR U OA ks DK, Lkl Alb&Vhu- 9 (Mailing address of applicant) State whether_applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder lnet4¢.IIAL CO3TiZAC=& Name of owner of premises N A R RY (VIA QSUAL L (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. 5SLA(la-H Plumbers License No. `?,y 69-4-N1p Electricians License No. NIC-S� Other Trade's License No. 1. Location of land on which proposed work will be done: 2'130 " FQVJW ck-,T bmm-r po►at i House Number Street Hamlet County Tax Map No. 1000 Section Block 2- Lot Subdivision ITtZ lac s q r 09-tE Filed Map No. 3Syy Lot 12 3 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy SSNuLE 1FA AN 3 TDWE-WQb- b. Intended use and occupancy Skhjc�J-E VA,-AmLti 3. Nature of wor (check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars •- 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front 1�f>I , Rear 51 , Depth 7-5 Height 19 Number of Stories i 'iz Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front I'�'r 4 Rear 135 Depth 5 L' 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated REsltab ma-ArkT use CODE 21� 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO_ 13.Will lot be re-graded?YES_NO)d Will excess fill be removed from premises?YES NO 14.Names of Owner of premisesi&,Cpv cugl Address ae�iFs i `y LPhone No. Name of Architect Kb1z n'St1fA" Address �2A ZYf-9Xlt0TR Phone No1031 Cd -Ll Name of Contractor OF skPN-e W e%t{i­ Address to(,aLIUT�wTg Phone No. to3 25Z- (02y Kwv: VALY- 44 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of atidal wetland?*YES NO­X_ *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO-)O— *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) UkISibpi-cy- Ib1w*k1 being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the C-0117t A01)9_ (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Swornlo before mes day of ( 20 (� Jenna Cristino Notary Public-State of Newya�&k No.01C Notary PublicQualified in Suffolk Coun SignWe of Applicant My Commission Expires 6/22 2019 i gt1Ffat BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD n Hall Annex - 54375 Main Road - PO Box 1179 '� .. �TNold New York 11971-0959 MAY 1 5 2019 South , 1 Telephone (631) 765-1802 - FAX (631) 765-9502 roger.riche rt(cDtown.southold.nV.us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: 05 Act l Company Name: M Name: ein-- License No.: ME 5q z7�_-Y Address: V, . t'7 �1 Phone No.: JOB SITE INFORMATION: (All Information Required) Name: Mac'She�\ �ZeS\der�c� Address: Cross Street: tJ Phone No.: email: BIdg.Permit#: 17� Block: Lot: Tax Map District: 1000 Section: 2- a. BRIEF DESCRIPTION OF WORK(Please Print Clearly) Ne-ulaca o S 4%A\\ tt: e Circle All That Apply: Final Is job ready for inspection?: ES NO Rough In Do you need a Temp Certificate?: NO Issued On Temp Information: (All information required) Service Size 1 Ph 3'Ph Size:Zoo A # Meters 1 Old Meter# New Service a Reconnec Flood Reconnect- Service Reconnected - Underground-Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH 'APPLICATION g2-t2e�que't toi�Iln, c4ion Form-As ;IIT! 'n ;i ii ��-------------------------- �o�oSui:Fotk�oG� BUILDING DEPARTMENT-Electrical Inspector * TOWN OF SOUTHOLD c Town Hall Annex-54375 Main Road-PO Box 1179-Southold, NY 11971-0959 Telephone (631)765-1802-FAX(631)765-9502 Temporary Certificate # it a Date C(P(V J't" 2019 Customer Name gEf LL Electrician Name gp4aj ZLZ a'L'. Address Phone e-mail IdkotA&T e-mail A'S l414(er R(Opfd/VG•' 4L Phone License# vqzfyts SNL; f` V.SaF01K�` ` BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD y Town°Hall Annex -'54375 Main Road - PO Box 1179 '� ' Southold, New:York 11071-0059��p�s�' Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(c�southoldtownny.gov — seand(osoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: q Address: 7W VJ r Cross Street: Phone No.: Bldg.Permit L email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): (2c pq r Square Footage: Circle All That Apply: Is job ready for inspection?: F YES ❑ NO ❑Rough In ❑ Finale Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT # I Address: Switches 1 Outlets GFI's 1 t �r Surface Sconces I } H H's UC is Fans f` C Fridge HW 1 Exhaust Oven W/U G� 1 1 Smokes DW I Mini l yJ T 111 Carbon Micro ' Generat6r Combo I Cooktop Transfer AC AH Hood Service Amps Have Used Special: Comments V as Scott A. Russell . d�10SIJFFQ�f' ST01MWATIER..- v G E 1ENT SUPERVISOR � z I�v][A\1�A\ � SOUTHOLDTOWN HAIL-P.O.Box 1179 Town of Southold 53095 Main Road-SOUTHOLD,NEW YORK 11971 O . CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: (CHECK ALL THAT APPLY) Yes No ❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑[v�C: Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑[� E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑ °L] F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department witfyour Building Permit Application. S.C.T.M. #: 1000 Date APPLICANT: (Property Owner,Design Professional,Agent,Contractor.Other) District NAME: NP_1 SCS iL W A 1. I� GAS �/ 1 nmrSection Block Lot L� 1 FOR BUILDING DEPARTMENT USE ONLY* ** Contact Information J — Relcy6mr Vumtrrl Reviewed By: �- Property Address/Location of Construction Work: —Z — — — — —Date: — — — — — — — Approved for processing Building Permit. a a3o i?.2Vlt t��h — Stormwater Management Control Plan Not Required. (� A( XI Stormwater Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM " SMCP-TOS MAY 2014 >IIT1�. .pit TN OVAL H.S.NO. t `oww�t4e: ' Gp-ZAVZQ 4 V IZA BA��iNON ' f � a 751 CfLAIV�QIi:t� AVE_ S(TF1:Ox+X COIINTY'gEALTH DEPARTMENT B4OKLYN, NN. 41 Z$5 DATSMAY'31 1,977',* H. D. RFF. �tg t-►-el.ylZ-332-191} ' The 9eWta0e a1Eipona7 er.'vToter sL�Ar1Y �O l �u3or tion 101ale�been AREA'ZOEZ30 .fit. ti-@e inn6uttA b� thS aa;:N fA to be Ou'WIi�.c►toz-1 rt �,EA � __: '" I ►ao�s• �•- � Imle •Service_"ft _• I L foe dafaw" r0 U Lor ZZ F 4 � = H � i C3 z � � t :O i A i M:r cl ii— . >C:I m iCALaL ` •a, D o Be iron elre In O IA iD • a ;tell O n`Ifa.4onk 7 , ! TO THIS SURVEY ISA VIOLATION OF i ' I SECTION 7109 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING 1q` Q THE LAND SURVEYOR'S INRLD SEAL OR (T EMEOS5ED SEAL SHALL NOT BE CONSIDERED TO BE A VAUD TRUE COPY. • �-- --• s i GUARANTEES INDICATED HEREDN SHALL RUN - ONLY TO THEPERSON FOR WFIOM THE SURVEY u PREPARED,AND ON HiS SEHAIF 10 THE . { Ser. •F TITLE COMPANY,GOVERNMENTAL AGENCY ANC 1 LENDING INSTITUTION LISTED HEREON,AND ..„� 70 THE ASSIGNEES OF THE LENDING INSTI• TITLK' C"un`ir' TO ADDITIONAL INSTITUNTEES TIONS OIL SWBOY LRRWIBNT OWNERS. MAP of #._O'C' 2 3 GvorOtOC&d 10 thq ;TAMP 'M1Ap OF: C.7aELEN Ar-265 ATO&ZIEWt'" ChI4416 Titin"tHeurar6cts Cor+ang !!!tL (50{falk Gounbj Map arEd +T *tv SaiLI,"W d '544411s Btlltik AT 410 lmjrva E d 0 2115N'T RoplEmctt VAN tuYL, P. c. TOWN OP' SOUT140L.0 , N Y. e, LIc NOeU VS7f01et G .N.Y. TE�iT NOL¢ BUFF.CO.;IUM.OF NEl1LTFi 1Cat *TTtMzNT OF INTENT FOR APPROVAL OF GONffftU0MN ORL.Y ntri — TW WATER SUPPLY AND f[WACOC rGq'd.� DATLT DIJPOSIAL sYA'i•[MS FOR THIS I&SI. 611{!CR WILL CONFORM TO THE N.S.Rae.NO.: I1'f4NcAnc8 OF SUFFOLK CO. DEPT. 100 HEALTH. SERVI�>S. APPROVED: 17' APPLICANT 3/5/2019 IMG_1061.jpg Suffolk county Dept of Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE Name RICHARD OORBECKI Business Name GREEN WAY ALTERNATIVE ENERGY t This ceudies That the SOLUTIONS LLC ' bearer is duly licensed License Number ME-54277 by the County of Suffolk lssued: 10/2212014 c-miss,oner Expires: 1010112020 https:Hmail.google.com/mail/u/0/#inbox?projector-1 1/1 SUFFOLK COUNTY DEPT OF LABOR.- LICENSING&CONSUMER AFFAIRS 'HOME IMPROVEMENT CONTRACTOR LICENSE NANE CHRISTOPHER R WAHL " This,certifies that the B"'"ESD""E bearer is duly WAHL DESIGN AND BUILD CORP licensed bj the U—N— . County.of Suffolk 58416-M 04/20!2017 4 ;Com h+bn+r E%PRAMON DATE 04101/2019 , •a:. .'i''. ".r'' .ail' 1: 1 A SUFFOLK COUNTY DEPT OF LABOR, �:..' LICENSING$CONSUMER AFFAIRS MASTER PLUMBER NAM MICHAEL J LEOCADI This certifies that the h-rer is duly OINOS PLUMBING$HEATING INC licensed by the i County of Suffolk 03/29/2004 .34697-MP ,,,°,,, sxrnmoNare 03/01/2020 fable p602,X 1) Fa5tenincl Schedule ( partial table) fA�LF P 30l Joinb Pe5cription Number of Nails Nail 5pacinq ALLOWABLE PEFL�C110N OF 5TVUC1UpAL MNM15 b HOOF TAMING RAFTFM5 HAVING 5LOPE5 GMEATER THAN 3/ 12 L/ 180 #5 ITFOrMEn ITPAR @16" O.C. Rafter to fop Plate (foe-nailed) (3) IOd Com, per Mafter WITH NO FINI5HF19 CEILING AffACNEP TO RAFTER5 1 14 Nc1U5 LON w/ T" MINIMUM EMMATNf Ceilinq Joist to fop Plate (foe-nailed) (3) 8d Com, Per Joist C05 fo ILL EPDXY Mor?rpr (TTICAL) Coil inq Joist to Parallel Rafter (Face-nalled) (6) 16d Com, Each Lap INTEMIOR WA15 & FAMf1T10N5 H/ 180 1 EXI5T1NG EXISTING Ceiling Joist Laps over Partitions (Face-nailed) (6) 16d Com, Each Lap FLOORS & PLA5TEI;EP CFILING5 L/360 Collar fie to P.aRor(Face-nailed) (3) 1 O Cam, Per fie p� 0 Plockinq to Mafter(foe-nailed) (2) 8d Each End ALL OTHEM 5VLICTUP\A- MFM[3F1:5 L/ 240 — — Mim 13oard to Rafter (Euil-nailed) (2) 16d Each End EXTEMIOR WALL5 w/ FLA5TER OM 5TU000 FINISH H/360 :,. Top Plate to fop Plate (Face-nailed) WALL FMAMING (2) 16d' Per Foot FXTEPIOl? WALL5 -WIND LOA05a W/P0TTLE FIN15HE5 H/ 240 �XI511NG EX1511NG fop Flat-- at Intersections (Face-nail ed) (4) 16d Jolsts-each sideEXTFMIOR WALLS -WIND LOAPSa W/FLEXIF3LE FINISHES N/ 120 (3) 2"x 8" GIMP, (3) 2"x 8" 61M Stud to Stud (Face Nailed) (2) 16d 24" O.C. Header to Header(Face-nailed) 16d 16"o,c, along edges n ( x NOTE:; L-span length, H-span height � a, )AA �� �� a, The wind load shall be permitted to be taken as 0,7 times the Component and Z fop or[3ortom Plate to Stud (End-nailed) (2) 16d per 2� x stud i3A5 FNf 6AU& Aj0VF (3) 16J per 2''x 6 stud ClaJJInq loads for the purpose of the determininq deflection limits herein, (4) 16d per 2"X 8" stud b, For cantilevered members, L shall be taken as twice the length of the cantilever o n o <, EXI511NG EXISTING EXI511NG EX1511NG C 3 2"x 10" GI f? ( ) 2"x 10" GIi.MV (3) 2"x 10" 61MFP C 3) 2"x 10" Glop (3) 2"x 10" Gif'PDr [3ottom Plate to Floor Joist, [3and Joist or Plocki (face-nailed) (2) 16d' 2 Per Foot d, beflection for exterior walls with interior qupsum board finish shall be limited to O o '�z — — o — — o — — e — — _ -o — — ,L Fill nAMAGFP) I'M PAMACAW) U FLOOM FMAMING Per o'st an allowable deflection of H/ 180, MACE � Joist to 5r11, fop Plate or Girder(Toe nailed) (4) 8d r J i [3ridginq to Joist(foe-nail edo 0 SL ) (2) 8d Each End v Blocking to Joist(foe-nailed) (2) 8d Each EndCK :`� I 6011 fir; — oZS 13lockinq to 5111 or for Plate (f oe-nailed) (3) 161 Each Plock SZ/ 1 Ledger Strip to 13eam (Face-nailed) (3) 161 Each Joist I o I I QCID c' Joist on Led er to 13eam (foe-nailed) (3) 8d Per Joist Band Joist to Jolst(Fnd-nailed) (3) 16d Per Joist 1 13and Joist to sill or fop Plate (foe-nailed) (2) 16d' Per Foot ROOF 5HFATHING o o Structural Panels 8d-4' Fdge 6" Edge/6" Field 1'.3122 Wprotection, , indow fall p , _ z I ,n o 19wgonal Board 5heathinq �� 8d Inter, 6" Fdge/ 12" Field Window fall protection shall be provided in accordance with 5ection5 V3U,2,1 and : 1 X6 or I X8 ( 2) 8d Per Support t?312,2,2, I - I)i f" "x 10" or wider IC 3) 8d Per 5u ort CEILING SHEATHING 1 G sum Wall board 5d coolers T Ed e/ 10" Field I?312,2,1 Window 5i115, WALL SHEATHINGI � 5tnactural Panels 8d 6" Edge/ IZ" Field In dwelling units, where the top of the sill of an operable window opening is located Fiberboard Fanels l e55 than 24 inches ( 610 mm) above the finished floor and greater than 12 I #5 iTFOPMEn ITPAP @I6" O.C. 711611 6d 3" Fdge/6" Field inches ( 1829 mm) above the finished grade or other surface below on the exterior A-4 14INO-U5LON6w/ T" MINIMUMFMMI9MFNf 25/32" 8d 3" Edge/6" Field GAPS f0 IT rIU.W W11N Ff'OXY MOffAt; (TYPICAL)of the building, the operable window shall comply{ with one of the following. - Gup5um Wallboard 5d coolers 7" Fdge/ 10" Field U Hardboard 8d 6" Edge/ 12" Field I,Operable windows with openings that will nob allow a 4-inch-diameter ( 102 mm) S)— co rn Particle Board Panels 8d 6" Edge/ 12" Field sphere to pa55 through the opening where the opening 15 in its largest opened FOUNPATION PLAN [9iaqmal 13oard 5heathinq "x 6" or I"x 8" (2) 8d Per Support position, 1 U o � "x 10" or wider (3) 8d Per 5u ort �- Cp FLOOD 5HEATHING 2,0 erabl e windows that are provided with window fall prevention devices that A"1 �A I/ - I ' -O " 0 SMOKE ALAPM S z Structural Panels p p CAf 30N MONOXIPE ALAP.M " or less 8d 6" Fdge/ 12" Meld compIq with ASPM F 2090, v greater than I" 10d 6" Fdge/6" Field Piaqonal Poard 51eathinq Illy,6" or Illy'8" (2) 8d Per Support 3,Operabl e Windows that are provided with window opening control devices that Q-\ "x 10" or wider (3) 8d Per Su ort comply with Section 1:312,22, Nailinq requirements are based on wall sheathinq nailed E on-center at the panel edge. If wall sheathing rs nailed V1 on center at the panel edge S to obtain higher shear capabilities, nailing requiremnets for structural members shall be JcuHed, or alternate connectors, such as shear plates, shall be used to maintain load path, M312,2,2 Window opening control devices, �7 O 2 VVYIen wall sheathing is continuous over connected members, the tabulated number of nails shall be permitted to be reduced to 1-164 nail per font, Window opening control devices shall Complq with A51'M F 2090, The window s NAIL5 - Unless otherwise stated, si-r_es iven for nails are common wire sizes, Pox or pneumatic nails of equivalent diameter and q p q opening control device, after operation to release the control device allowing the equal or realer I to the s ecrfied common nails ma be substibaked unless otherwise rohibited, D^,;::,,, ( ! i'q R.F. .3� - g p p window to fullq open, shall not reduce the net clear opening area of the window unit �i� I. COMPLY WITH ALL CODES Oi= � F'51021. F'- -t �5 . r `" C � --- NEW YORK STATE & TOWN CODES �— fVl�L M 301, 2 ( 1) PE51GN LOA25 to less than the area required bu Section { i.s F1T ' ��' � �_ AS REQUIRED .. DITIONS OF CLIMAI1C & GEOGMAPHIC nE51GN CMIVIA PERP LDAP LIVE 0A19r" r $Or,nuL uViu� _ SL MOUNP SNOW LOAP 20 P,S,F ROS - - 12 P,S,F Af 11C - - 20 P,S,F F' Y ., -.. - - 1 C Gu i HOLD TOWN PLANNA ^' � ' t �, , WINn LOAP 140 MPH - I2 P,5,F SLFFPING �, ,; S08 Room FLooM5 - 30195F pp�C110N OF WINPOW5 Fi?OM WIND-60MNE PM\15 �. i:,...,i_.,_. �, 5F15MIC CAEGORY BATH 0FM FLOORS �OF,S,F C. I - �; "71R lC-0, + ti U ; ' :( T - WFATHEMING SFVFMF KITCHEN FLOOR - 22 P,5,F ALL CONSTF'_.'C iCNI CHALi_ �! �T THE 0f1-IER FLOORS - IZ PS,F Wood structural panels with a minimun thickness of-7116 inch and a r,FOUIr0AiE-NTS OF 1 HE COH-3 Or N74"! FM05TLINF DEPTH 36 IN, maximum span of 8 feet shall be permitted for openinq protection in YORK STATE. rlCg P,ESf',tdSj4' E FC'R TFRMITE MOPFMATE TO HEAVY one and two storN buildings, Panels shall be pre oat to cover the glazed DESIGN OR CO !STRIJCTIOI I ERRORS. . PECAY SLIGHT TO MOPEMAt openings with attachment hardware provided, Attachments shall be provided in accordance with Table 1301,212 of the Residential Code WINTER PF51GN TEMP. II' F of New York State, '!"i;ly"a.`'^ ICE & WATFI5HIELPQuln _ (section V905,1.2 IVC) _.. ' FLOOD NAZAMPS 1'Af3LE 1301,2,1,2 j ZONA -X r . . . ._ .. ._ WINP-13OPM PFPP,15 PHOT 010N FA5tNING nUL� E . .s FEMA MAP # 3610300069N � �� AIR FRFFZING IN12FX 599 X01 WOOD STIUCTIaF�AL FANEL5 a, c, G F m. AS H&T P00F 5HN6�F N01t i ASTENEf?SPADING FF 1, A5PHALf 5HINIGLF5 SHALL AVF 5FLF-5FAL 5TP.IP5 OR [3F IN HGP OCKIN , ANP COMPLY WITH ASTM 225 OR n 5462. PANEL 5PAN < PANS 5PAN < PANS 2, FA5TENFR5 FOR A5FHALf��HINGLF5 SHALL 13E GALVANIZFP 5TFFL, 5fAINLF55, ALUMINUM, OR COPPER ROOFING NAIL5, FA5TENM TM < 4 roor <6 FOOr <8 roof "'�` o` CU'DC. MINIMUM 12 GAGF 5HANKFI? WITH A MINIMUM 3/8 INCH PIAMESP, HEAP, OF A LENGTH TO FENFTP\hTE THMOGN THE 2-112 INCH, #6 ei_rci t i�r3srr ROOFING MAT FFIAL5 ANP 5HEATHING, woos 5C W5 16" 12" 9" �►Re4irA;; 3, A5PHALf 5HIN6LF5 SHALL HAVE f1f MINIMUM NUMBER OF FA5TFNFM5 MFQUIPTP 13Y THE MANUFACTUITIM' 2-112 INCH, #8 4, FOM NOMMAL APPLICATION A5PHALf 5HINGLF5 SHALL PF SFCUMEP f0 THE HOOF WITH NOf LF55 THAN 51X FA5TENEM5 WOOn 5CIEW5 1 16 16" 12" PFR 5TMIP 5HIN6LF OM TWO FA5TENFM5 PEM INPIVIPUAL 5HINGLF, 5, ICE ANP WATER 5HIFLP UNPFMLAYMFNf SHALL 13F IN5TALLFP Af ALL PPTFPGF5, (R90512 IMO a, This table is based on 110 mph wind speeds and a 33-foot mean roof height, b. Fasteners shall be installed at opposinq ends of the wood structural panel, C. Nalls shall be IOd common or 12J box nails. O v J, More screws are attached to masonq or ma5mml stucco, then shall be attached utilizinq vibration-resistarrb anchors havinq a minimum ultimate 0 withdrawal capacit,N of 490 pounds, \ N O WANLn & C� 1911 GZN�PAI. I, Contractor shall inspect prerriises and verifq job conditions prior to commencement of work, 2, 12imen5ion5 as shown are approximate. Contractor shall set up work in accordance with existinq conditions. Contractor shall notify Architect of anq discrepancies prior to construction, 3, Al construction operations shall conform to the recpirements of the 2015 International residential Code, the 2011 Supplement,to the Uniform Code, the rules and regulations of the Town of 5outhold, and all other laws and ordinances as may be applicable to the construction covered by O I � � these plans and specifications, FX1511NG �X15TING �X1511NG -_ 4, Contractor shall supply all tails, labor, materials and appurtenances necessarg to complete the work - as called for bq these plans and specifications, I ITIVOW # z &115 f M z r� 5, All construction operations shall be covered by the Contractors insurance policies. Copies of l certificates shall be su lied to the Owner u request, & f PP I l II' 1012" 411 g�_B/2��� 4�� 6, The Contractor shall, upon completion of work, rerrove from the premises, all debris, tools, excess 00 oe- 01 SIZ 0 11 10 materials and appurtenances, and leave the premises in "broom clean" condition, P�r"OOM2 C WOOM 2 7, Contractor shall coordinate with separate contractors employed by the Owner for the installation n � -- of alarm system, stereo system, etc, z v_ O B. This builds has been Jess ied in accordance with American erican Forest Association and Paper I & o 111 p Q) ¢ C AF & PA) Wood Frame Construction Manual for One & fwo Familq 12welling5 C WFCM) °x _ 2015 Fdbon and the WFCM Guide to Wood Construction in Nigh Wind Areas z - 26 x 68 NPJ,� ® 26 x o (140 MPH - Pxposure P) o `Q' _- _ - 9, All design & construction procedures shall comply with the International residential Code & New York - " I U pp lechaniA system shall comply with chapters 12-2-t, Plumbinq system N I5'-I " �" 5'-10" 4" 1_11 X11 61-11 411 �XI511NG C?InG 3, 91 State 2017 Su lement, N shall comply with chapters 25-32, Electrical 5g5tem shall comply with chapters 00 S� �b .................. �b 416e .... Z �nT� UNC 0F CI G,[31?�AK 06 PPAMING L S o CLOS, CLOS,`_� _ ❑ < z 1. All lumber shall be grade marked I o z o 2. Al framing lumber shall be 12ouclla5 Fir (.arch, f- 8751'51, unless otherwise noted `� 0 3, Provide double headers and trimmers around floor, ceilirq and roof openirq5, and under parallel partitions exceedinq 6-0" in length, 5, Nominal sizes of lumber noted, actual sizes used for stress calculations, N 6, Contractor shall install Nockinq and firestops in accordance with section P502,13, 602,8, 302,11 Q & 302,12 of the International residential Code, 7, 5heathinq shall be 1/2" C--12 exterior plgwood on walls and roofs, 5ubfloorinq to be pqw � q ood lued and nailed, 8. Al lumber that is burned or charred shall be removed and replaced, �XT�1101 1`I1\1I5H�5 I, Al new window units shall be 400 Series ANI2Fr51�1\1 units, 2. Windows and doors shall be complete with white clad exteriors, low-� glass, interior and exterior grills A-4 - as shown on elevations, locks,insect screens and factorg installed, flush mount open inq control devises U for "fall protection" where Indicated on plans, 3, roofing shall be dimensional shingles over 15# felt, Provide standard qa qe aluminum flashinq at all vallegs and roof/ wall intersections, Provide "Ice and Water Shield" at all drip edges and vallegs, U C 12rip edge installation to conform with V905212) Al existing roofing materials to be removed 5�CONP 4, Walls to receive new vin I Sidi F�OOP\,, IN CC) INTErIOr PINI51-I�5 ® SMOKE AI.APM U M I, All exists d laced,all is to be removed and re 0 CA ON MOHOXIP2 ALAPM p < _ 2, Al walls and coil incl to receive 1/2" thick ggp5m wallboard with three C 3) coat tape and x spackle treatment, readq for paint, 2. Al drgwall shall be 5MW APPLE12, S 3, All drgwall outside corners tis receive metal corner bead, 4, All Interior doors to be removed and replaced, 5, Millwork as specified in construction contract, I O s CC) 6. Kitchen cabinets and appliances shall be removed and either reinstalled or replaced C see I 111V20210 �XI511NG EXISTING construction contract)fdlowinq restoration work, WfkHFA11NG MI, Oil fired boiler and water heater to be removed and replaced, :>: & 5 f QF 2, All components of sgstems shall comply with the requirements of the International Enerclg Conservation Construction Code and New York State 5upplement, V5 SIZ }b 41 00 bIZV All CON1211IONINCA ITMOW I. Contractor shall install a new, single zone central air conditioninq system complete with condensinq unit, , = I I N < @9 21 air handler, ductwork, refricgerant piping, diffuser grills, thermostat, o S N 2. 5g5tem shall be sized and installed in accordance with all requirements of the International �,z > CL.I K11'CN�N nI N I NG p00M GP�,AG� n residential Code, the 2017 Uniform Code Supplement and the 2016 New York�nercgq Q & sof FXI511NG 0126F Conservation Construction Code, n x �I.�C11?ICAL I z , All wirinq, fixtures and devices are to be removed and replaced. CLOS 1, Al electrical work shall be performed under separate contract bq or under the direct supervision of a � �o ( � I icensed electrician, who shall provide an Underwriter's Certificate at completion of project, MIA ❑ v N ® 2, Pecessed ceiling fixtures(hi-habs) shall be supplied and installed bq Contractor(Halo H-5 or _ ( o H-5 ICAT) with 65 watt equivalent 1.x12 lamps„ o I X l2ecorative, surface mount fixtures shall be supplied bq Owner and installed bq Contractor, OLI N I N 3, Outlets shall be white grounded type, GPI and / or weatherproof where required, v C6) 4, Switches shall be white, silent, rocker t ipe, 5, Contractor shall supply and install smoke detection devices in compliance with sect ion 1314 of the International residential Code, mpoo0M I FN1P?Y DIVING rOOM 6. Contractor shall su I and install carbon monoxide detection devices in compliance with section I ® �XI511NG pp y I I O\/MAn n00I? P515 of the International residential Code, - o PI.UM131NG EXISTING EXISTING o o � , Al plumbinq work shall be performed bq or under the direct supervision of a licensed plumber, �XI511NG Complq with local codes, 1 2, Water supplq lines shall be copper with brass fittings and lead free soldered joints or PAX, V 3, Waste lines and vent lines shall be PVC pipe and fittings, 4. Bath fixtures shall be removed and reset fdlowinq restoration work, O N Ml5al,!,AN�06 1. 6att type insulation shall be installed to fill framing cavities exposed during the course of FIP\5f � ��AN this project, in accordance with Section 503,1,1 of the Fnerclq Conservation Construction Code, I \ N 2, Al wood, metal and masonry joints shall be caulked with pressure qun applied sit icon or latex A- 5CA r 1/4 " - 1 ' -0 " sealant, Provide foam backer rod where required at deep joints, ® SMOKN ® C"\ ON MON MONOXIfZ AbApM & � 1911 ALUMINUM CAMP FA50A � ASpNALr SNINGLU5 `s n ALUMINUM CKTN2 rA50A RLr_ o -- AL �x1s11NG z A519HALr ANCU5 �xlsnNG CxIstING Jllu �x1srING tLJULLIAl!LiLl Ill— o -- LLL - O jd� z 77 � v FT_Q 3Z � IsFM � FX1511NG �XIStING p OZS O OILLEXISTING � � } 0"5 a Mp, I.H z Hill LM O � — > 11 LLLLL1l 11111 1 > ANO --- - - N �XI511NG III IIIHIH EY15, VINYL 5112ING VINYL SInING P\'16HT 51P� �L,�VATION 2 PAP FLFVATION - A-3 5c&F 1/4 " _ P _0 " A-�j 5CA1 r I/h _ 1 ' _o S z � X E , O Oco S ALUMINUM CAM[? ME130AP.125 wNr 0 ATl-IALr SNINGI.�S O vI-A - - _ ALUMINUM CAPPR? FASCIA o - A5rHALr 5HINGL�5 o � v _ zHill 111111 lill I - - _ Mill 111 11 111 11 111 11 111 11 1 O O HI5TING FXI511N6 rXI5TIN6 FXI5TIM6 FXI5TIN66 ALL O O IJU v v 11 Hill ryb_ NG IT tjm z z z 32" x 16" 135AAf.5A5H 32" x 16" 135MT,SASH I IN GAIN.%,PaAWAY VINYL 5112ING IN GAIN.5t.aAWAY I VINYL 5119ING I I ALUMINUM CAMP FA50A � I I O I I v I I � Lfff 51PF FL�VAfION MONT' LFVATION � n n _ n A-� SCALA : ii� 1 ' -0 " /�-3 scAL� 1�� 1 -o N O WNLn & C3 1911 \� CAPPEP 5HIN6LP or,CONTINUOU5 f?IPGE VENT (5EP PLAN) I X"x 20ga 5TEFL 5TPAP Wn rKTfp 51MP50N C520 Op FOI.IAI, ASPHALT SHINGLES (6) 8d NAIL5 EACH ENP ICE & W EP, 5HIPLP UNI)MAYMENT or, 1/2" PLYWOOP SHEATHING COLLAP.11E5 @ rVEW STEP rA P,, > O 2" X 8" MTEPS @ 16" O.C. MAY 13�CONNECTOt5,UP( 6�lOd NAILS 12 12 (EACH ENP) 2+ PIPGE 13FAM o � s MATCH A5 PLr;PLAN v� EX1511NG TING IQ+_ ALUM, CAPPED PA5CIA TO MATCH PXI5TING ASPHALT SHINGLES WOW PgtP,5 A5 PEP PLAN Z 2" x 6" CLG. J015T5 @ 16" O.C. 15# FELT (4) 16d NAIL5 AT Q 1/2" PLYWOOD SHEATHING EACH WTEP/vl%lG 51MP50N "1-12" Op WU& 2" X 8" P,AFfEV5 @ 16" O.C. CONNECTION (MTEp5 TO 5TUP5) P�nt?OOM 3 CLOS, ��� CONNPCTOp5 @ 16" O.C. %" CDX 000E 5HFATHIN6 HOLD PLYWOOD PACK FrOM U PIPGE POIF,AIP,CIPC1 LA110N ALUM, CAPPFP FASCIA TO MATCH EXI511NG I15T#I13UILI)NI G FELT 06 ot F1f3Pp6LA55 P00F 541\16LE5 N >- pEPL 6UpN�n Or,CHAP�?EP 2" x 8" � � � z V�NT�P SOPC IT TO MATCH �XI511NG PLOO JOISTS ANI) %" PLYWO012 5UI3PLOOP V�NT�P SO�PIT TO MATCH �XI511NG AS VE IPSP 9� � Q e VINYL SIDING PATH 1 C 5, 51PIN NYL G _ I X x 20ga 5ffL 5f PW EWFY 5TUP s i' FOAM PAXP,60AR'n I3�n�00M I VIM BACKED( OXV - N o "TYVEK" NOUSEWPAP "TYVEK" HOUSEWPAPN SIMPSON C520 Op EQUAL � � N v2°CPX PLYWOOD SHEATHING v2"CDX PLYWOOD 51 FATHING ( 5) 8d AT EACH �Nf7 2"x 4" STUDS @ 16" O.C. 2"x 4" 5TUD5 @ 16" O.C. BATT WSULAWN(P-15) BATT IN19LAWN(C?-15) v 2"GYP, 130AP.1 v 2"6T.130AW SL _ f?�PLACP �XIST1NG N (3) 2" x 10" GIpPPf; I'4"x 20ga STEL STP.At'EVEpY STUD SIMPSON C520 Op EQUAL I;UN UNDER 51LL PLATES ANP UP _ II STUD, MINIMUM (4) 8d U NAIL5 EACH ENP 5/8" 4) ANCHOR CD � 13OLT @ 25" MAX, — T W/ 5" 5QUA'� WA5HFt?5 U 12" PPOM COPNEI?5 MAX, co S z TIF POWNP�TAL X zy SCALE 1/ 1 ' -0 " SCALE 3/V' 1 _0 S Qco � � o � S _ V n O O HEAnEp A5 PEP\ PLAN O WA02 OPFNING E0p NEW WINDOW (Op EXTErlior POOP) I II II I j N01 ECIAL ITT j CO ECTOp5 'P 1 THIS AM � 1 I II II I e I II II I I II II I O O N N SCALE WANLn & � 1911 MP,6Y CONVNA110N CON51PUC110N COPS CNAMr, 5 C IT] FX1511% PULIANG5 0 5FC110Np501 cs o GMM # �z VIN 1;501,1 Scope, s 1'he provisions of this chapter shall control the alteration, repair, addition and `n A. INSULATION SHALL ACHIEVE RESNET DEFINED GRADE I INSTALLATION A. INSTALL A RIGID AIR BARRIER TO SEPARATE change of occupancy of existinq buildings and structures, THESE DETAILS AND NOTES 5 H ALL APPLY ONLY TO ORALTERNATIVELY, INSULATION GRADE 11 F TO AL13E UWITH SED AS AN AIR BARRIER SHEATHING. . UNCONDITIONED - IRE PORCH ATTIC FROM CONDITIONED SPACE. B. SUBFLOORB. SEAL ALL SEAMS, EDGES,GAPS AND HOLES NEW WI N D O W5 BEING INSTALLED SEAL ANY OPENING. WHERE FIBROUS INSULATION USED IT IS TO BE P E DUCT — WOOD FRAMING IN THE AIR BARRIER WITH CAULK OR FOAM. f?501,1,1 AdAltlon5, alterations, or re airs; General, INSTALLED TO ITS FULL THICKNESS,WITHOUT MISALILI GNMENTS,GAPS AND p VOIDS, STAPLED TIGHT U51NG THE MANUFACTURERS TABS AND EXTENDEDAye Z NEW LIGHTING F I XT U RE5 BEING I N STA LLE D THE FULL SIZE THE OPENING INTENDED. FINISHED CEILING O AAAltlon5, alterations, or repairs to an existing building, building system or portion C.WHERE PENETRATIONS OF ANY TYPE OCCUR IN FIRE RATED WALLS AND CONDITIONED _ 502 F' 03 or p PARTITIONS,THE SEALING MATERIAL USED AROUND ANY OPENING IS TO �— thereof shall comply with Section p � 50�, Unaltered portions Of BE RATED AND INSTALLED As REQUIRED BY THE MANUFACTURER. A. INSTALL RIGID,CONTINUOUS AIR BARRIER MATERIAL TO SEPARATE THE AIR BARRIER—PORCH NEWPIPING AND DUCTWORK P E N ET RATION 5 D. UNDER NO CIRCUMSTANCES 15 CONSTRUCTION ADHESIVE TO BE USED EXTERIOR FROM THE CONDITIONED SPACE. the existing building or building supplq system shall not be required to comply with AS AN AIR BARRIER OR TO SEAL ANY OPENING. O NEW EXHAUST FAN 5 AND ANY NEW DUCTWORK E. SEAMS/JOINTS TO BE SEALED: M CUT ALL PENETRATION HOLES CLEANLY WITH A SAW OR DRILL AND NOT INTERIOR A. INSTALL A RIGID AIR BARRIER TO SEPARATE 1.WHERE STUD MEET5 EXTERIOR SHEATHING MORE THAN I"LARGER THAN THE DIAMETER OF THE PENETRATING EXTERIOR FROM CONDITIONED SPACE. ` \ thl5 code, 2.WHERE PLATES MEET STUDS(AND TOP PLATE JOINT) OBJECT TO ALLOW FOR PROPER AIR SEALING. SEAL ALL GAPS AND HOLES B. SEAL ALL SEAMS, EDGES, GAPS AND HOLES v 3. TO UNCONDITIONED SPACE WITH CAULK OR FOAM. FIBROUS INSULATION 1N THE AIR BARRIER WITH S, GAS FOAM. �� N MEETSESILL.ILL MEETS FOUNDATION WALL AND FLOOR FRAMING IS NOT TO BE USED TO SEAL AIR BARRIERS. ACK WITH RIGID AIR BARRIERCAULK OR OTHER SUPPORTING MATERIAL TO SEPARATE THE EXTERIOR FROM THE C. SUPPORT INSULATION AT OVERHANG WITH F501.2 existing buildings, 4.WHERE FLOOR FRAMING MEETS WALL FRAMING. INTERIOR SPACE. C 5.WHERE 5UBFLOOR MEETS FRAMING AT STAVES OR NETTING. VAPOR BARRIER TO s� - CONDITIONED/UNCONDITIONED SPACE. FACE PROPERLY. AFTER INSTALLATION, Cz s O �xce a5 5 ecifiecl in thi; chapter, this code shall not be used to require the O O ENCLOSE OPENING WITH RIGID AIR BARRIER. pt p q C. WHERE A RATED PARTITION IS PENTRATED, APPROVED, RATED - nz removal, alteration or abandonment of, nor prevent the continued use and COMPLIANCE NOTES- MATERIALS MUST BE USED. A z lu � U maintenance of, an existing building or building system lawfully in existence at the DUCT, PIPING, WIRING AIR BARRI E R—OVE ISH AN G - time of adoption of this code, 1,2"=1'_0" �= OSEAL DETAIL S � I/2"=I'-O" A. INSTALL INSULATION WITHOUT MISALIGNMENTS, �-� � N O COMPRESSIONS, GAPS OR VOIDS IN ALL EXTERIOR FOR GRADE I INSTALLATION, WALL INSULATION WALL CAVITIES BEHIND TUBS, PREFABRICATED N SHALL FILL THE CAVITY COMPLETELY TOP TO - A. SEE GRADE I INSULATION DETAIL THIS TU BOTTOM AND 51DE TO 51DE WITHOUT SUBSTANTIAL C SHEET. FIREPLACE OR STAIR LANDINGS, GAPS OR VOIDS AROUND OBSTRUCTIONS C (BLOCKING, ETC)AND BE SPLIT, INSTALLED OR B. BACK WITH RIGID AIR BARRIER OR OTHER wtt B. BACK WITH RIGID AIR BARRIER OR OTHER 5�C110Np502 FITTED TIGHTLY AROUND WIRING AND OTHER SUPPORTING MATERIAL TO SEPARATE THE u� SUPPORTING MATERIAL TO PREVENT INSULATION SERVICES WITHIN THE CAVITY. EXTERIOR FROM THE INTERIOR SPACE. FROM SAGGING AND TO CREATE A CONTINUOUS THERMAL BARRIER. /U/V(LIONS INSULATION SHALL BE ENCLOSED ON ALL G SIDES C C. INSTALL BACKER ROD AND/OR SEAL ALL (TOP 4 BOTTOM,51DE TO 51DE 4 FACE TO FACE) SEAMS, EDGES, GAPS AND HOLES AROUND BATH .. SEAL ALL SEAMS, EDGES, GAPS AND HOLES IN � 1:502,1 General, AND BE IN SUBSTANTIAL CONTACT WITH THE O THE WINDOW/DOOR AND IN THE AIR BARRIER THE AIR BARRIER WITH CAULK EP FOAM PRIOR TO SHEATHING MATERIAL ON AT LEAST ONE FACE WITH CAULK OR LOW EXPANSION FOAM FINAL TUB, PREFABRICATED FIREPLACE OR STAIR Additions to an existing buil4q, buildinq system or portion thereof shall conform to (INTERIOR OR EXTERIOR)OF THE CAVITY. PRIOR TO FINAL INSULATION INSTALLATION LANDING. (INCL. BOXES, PIPES AND CABLES). LANDINGVC NOTE-AIR BARRIER AT PREFABRICATED FIREPLACE the provisions of this code a5 those provisions relate to new construction without SIDE STAPLED TA135 ARE PERMITTED WITH NO MUST BE 5/8"TYPE'X'GWB SEALED WITH RATED BUCKLING AND PROVIDED THAT THE BATT BE D.NUMBER OF JACK STUDS DETERMINED BY FOAM OR CAULK. requiring the unaltered portion Of the exi5tirq buildinq or building 5y5tem to comply COMPRESSED AT THE STAPLED EDGES ONLY AND RCNY5. with this code, AAdltlon5 `shall not create an unsafe or hazardous condition or ONLY TO THE DEPTH OF THE TAB. - E. WINDOW/DOOR TO RETAIN ENERGY STAR LABEL UNTIL FINAL CERTIFICATE IS ISSUED. overload exi5tinq building systems, An addition shall be deemed to comply with this I N U LATI ON DETAIL - _ code where the addition alone compl ie5, where the existing bu ilA inq and addition t/2"=I'-G' TYP . WINDOW/DOOR DET. STAIR LANDING I/2"=I'-0" comply with this code a5 a single building, or where the buildinq with the addition A.JOINT BETWEEN TWO TOP PLATES. INTERIOR GENERAL REQUIREMENTS A CONTINUOUS AIR BARRIER INSTALLED IN THE BUILDING AIR-PERMEABLE INSULATION SHALL NOT BE USED ASA B.STUD TO EXTERIOR SHEATHING CONNECTION XG FRAMING, I G"OC ALIGNED AIR BARRIER v uses no more ener than the exi5tin buildin , Additions shall be in accordance with ENVELOPE.THE EXTERIOR THERMAL ENVELOPE CONTAINS A SEALING MATERIAL qy q q (ALL AROUND)PRIOR TO INSULATION INSTALLATION.LA2) LVL HEADER C. FLOOR FRAMING TO SD ETA I L5 CONTINUOUS AIR BARRIER. BREAKS OR JOINTS IN THE AIR UBFLOOR CONNECTION EXTERIOR Sect ion 1:502,1,1 or p502,1,2, BARRIER SHALL BE SEALED. (ALL AROUND) 2"RIGID INSULATION (R-I O) CEILING/ATTIC THE AIR BARRIER IN ANY DROPPED CEILING/5OFFIT WILL BE INSULATION IN ANY DROPPED CEILING/50FFIT SHALL BE D.JOINT OF TWO SILL PLATES AND ALL ANCHOR 112"=P-O" BOLTS PENETRATIONS. Z ALIGNED WITH THE INSULATION AND ANY GAPS IN THE AIR ALIGNED WITH THE AIR BARRIER A. INSTALL HEADER AS PER RCNYS(2)LVL AND SEAL ALL EDGES, BARRIER SHALL BE SEALED. ACCESS OPENINGS, DROP E. SILL TO FOUNDATION WALL CONNECTION(y'XG" SEAMS GAPS AND HOLES WITH CAULK OR FOAM PRIOR TO FINAL EXTERIOR A. INSTALL CONTINUOUS INSULATION (� SILL INSULATION,TERMITE SHIELD,y"XG"SILL INSULATION INSTALLATION.. WITHOUT MISALIGNMENTS, GAPS,VOIDS 5 C11 N�5 5 DOWN STAIRS OR KNEE WALL DOORS TO UNCONDITIONED INSULATION;TERMITE SHIELD IS NOT TO COME AI.Tp ON5 ATTIC SPACES SHALL BE SEALED. INTO CONTACT WITH FOUNDATION WALL). B. INSTALL TWO LAYERS OF I"OWENS COROR COMPRESSIONS IN WALL. x CORNING FOAMULAR 250 RIGID EXTERIOR WALLS THE JUNCTION OF THE FOUNDATION AND SILL PLATE SHALL CAVITIES WITHIN CORNERS 4 HEADERS OF FRAME WAILS C INSULATION(R-5 EACH)50 THAT EDGES ARE TIGHT AND COMPLETELY B. BACK WITH RIGID AIR BARRIER OR F505,1 General, BE SEALED.THE JUNCTION OF THE TOP PLATE AND THE TOP SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY SEAL All SEAMS, EDGES,GAPS AND HOLES FILL OPENING. OTHER SUPPORTING MATERIAL TO PREVENT OF EXTERIOR WALLS SHALL BE SEALED. KNEEWAUS SHALL WITH R-3 INSULATION/INCH MINIMUM EXTERIOR THERMAL AROUND PERIMETER AND IN THE AIR BARRIER WITH INSULATION FROM SAGGING AND TO C Alterations to an buildinqor structure shall com I with the re uirements of the BE SEALED. ENVELOPE INSULATION FOR FRAMED WALLS SHALL BCAULK OR LOW EXPAN51ON FOAM PRIOR TO FINAL E _ C.WHERE A TRIPLE HEADER IS REQUIRED, INSTALL ONE, I'THICK LAYER CREATE A CONTINUOUS THERMAL BARRIER. `U � yp q INSTALLED IN SUBSTANTIAL CONTACT AND CONTINUOUS INSULATION INSTALLATION(ITEMS A, B, C, D AND E, OF INSULATION(R-5). -2 INCLUDING BOXES, PIPES AND CABLES). C`1 code for new construction Alterations shall be such that the exi5tinq build incl or ALIGNMENT WITH THE AIR BARRIER C. INSTALL TOP 4 BOTTOM PLATE AT ALL HEADER DETAIL INTERIOR KNEEWALtS. WINDOWS, DOOP.S 4 THE SPACE BETWEEN WINDOW/DOOR JAMBS AND FRAMING structure i5 no l e5s conforming to the provisions of this code than the existing SKYLIGHTS AND SKYLIGHTS TO BE SEALED. 5 EALI N G DET. EXTE R. 1/2"=1'-0" C. SEAL ALL SEAMS, EDGES, GAPS AND O S � buildin or structure was prior to the alteration, HOLES IN THE AIR BARRIER WITH CAULK OR G) Y RIM JOISTS RIM JOISTS SHALL INCLUDE THE AIR BARRIER RIM JOISTS SHALL BE INSULATED. 1/2'=t'-O" A. INSTALL I XG NAILER AT 2X4 FOAM. � n XG FRAMING, I G"OC FRAMING AND RUN INSULATION FLOORS(INCLUDING ABOVE THE AIR BARRIER SHALL BE INSTALLED AT ANY EXPOSED FLOOR FRAMING CAVITY INSULATION SHALL BE INSTALLED UNCONDITIONED SPACE CONTINUOUSLY BEHIND. D. DETAIL 51MILIAR AT SKYLIGHT WELLS. X4 FRAMING, I G"OC � GARAGE AND CANTILEVERED EDGE OF INSULATION TO MAINTAIN PERMANENT CONTACT WITH THE UNDERSIDE EXHAUST FAN a/- Alterations to an existing buildinq, building system or portion thereof shall conform to FLOORS) OF SUBFLOOR DECKING,OR FLOOR FRAMING CAVITY B OXG NAILER B. SEAL ALL SEAMS, EDGES, GAPS AIR BARRIER DETAIL— 9— INSULATION SHALL BE PERMITTED TO BE IN CONTACT WITH PLYWOOD 5UBFLOOR �, O AND HOLES IN THE AIR BARRIER / the rovi5ions of this code a5 the relate to new construction without re ulrin the THE TOP 51DE OF SHEATHING, OR CONTINUOUS INSULATION w WITH CAULK OR FOAM PRIOR TO p y a q LIGHT FIXTURE K N E E WA L L CONDITION INSTALLED ON THE UNDERSIDE OF FLOOR FRAMING AND —WOOD FRAMING z FINAL INSULATION INSTALLATION unaltered portions Of the existing building or building system to comply with this code, EXTENDS FROM THE BOTTOM TO THE TOP OF ALL PERIMETER FAN (17C. BOXES, PIPES AND CABLES). O FLOOR FRAMING MEMBERS FINISHED INTER./EXTER. WALL DET. 112"=IO Alterations Shall not create an unsafe or hazardous condition or overload exi5tinq �-� CRAWL SPACE WALLS EXPOSED EARTH IN UNVENTED CRAWL SPACES SHALL BE WHERE PROVIDED INSTEAD OF FLOOR INSULATION, CONDITIONED SPACE A. INSTALL INSULATION WITHOUT building systems, Alterations shall be 5uch that the exi5tinq buildinq or structure COVERED WITH A CLA55 I VAPOR RETARDER WITH INSULATION SHALL BE PERMANENTLY ATTACHED TO THE 1/2"=P-0" MISALIGNMENTS, COMPRESSIONS, GAPS OR OVERLAPPING JOINTS TAPED. CRAWLSPACE WALLS. A. INSTALL RIGID, CONTINUOUS AIR BARRIER MATERIAL TO SEPARATE THE VOIDS IN ALL EXTERIOR WALL AND BAND JOIST uses no more energy than tg q prior exi5tin buildinq or structure to the alteration, EXTERIOR FROM THE CONDITIONED SPACE. ATTIC @ A. BEFORE INSULATING ATTIC,SEAL ALL TOP CAVITIES AND IN CONTACT WITH ALL SIDES OF SHAFT PENETRATIONS DUCT SHAFTS, UTILITY PENETRATIONS, AND FLUE SHAFTS PLATES TO INTERIOR CLADDING THE CAVITY. Alterations to existing buildings shall complu with Sections V505,1,1 LI-rOUgh OPENING TO EXTERIOR OR UNCONDITIONED SPACE SHALL B. CUT ALL PENETRATION HOLES CLEANLY WITH A SAW OR DRILL AND NOT CONNECTIONS WITH FOAM OR CAULK TO NOTE-VERIFY ADEQUATE FIRE-BLOCKING. IXIBE SEALED. MORE THAN I"LARGER THAN THE DIAMETER OF THE PENETRATING OBJECT STOP AIR IEAKS FROM ATTIC SPACE TO TO ALLOW FOR PROPER AIR SEALING. SEAL ALL GAPS AND HOLES TO CONDITIONED SPACE. B. BACK WITH RIGID AIR BARRIER OR OTHER NARROW CAVITIES BATT5 IN NARROW CAVITIES SHALL BE CUT TO FIT OR UNCONDITIONED SPACE WITH CAULK OR FOAM. FIBROUS INSULATION 15 SUPPORTING MATERIAL TO SEPARATE THE NARROW CAVITIES SHALL BE FILLED WITH INSULATION ON NOT TO BE USED TO SEAL AIR BARRIERS. ACK WITH RIGID AIR BARRIER CONDITIONED SEAL ALL SEAMS, EDGES, GAPS AND HOLES INSTALLATION READILY CONFORMS TO THE AVAILABLE OR OTHER SUPPORTING MATERIAL TO SEPARATE THE EXTERIOR FROM THE SPACE AROUND THE WINDOW/DOOR AND IN THE AIR A EXTERIOR FROM THE INTERIOR SPACE. p503J J 13uddinq envelope, CAVITY SPACE. INTERIOR SPACE. BARRIER WITH CAULK OR LOW EXPANSION O O C.SEAL ALL SEAMS, EDGES,GAPS AND HOLES FOAM PRIOR TO FINAL INSULATION FZ � GARAGE SEPARATIONS AIR SEALING SHALL BE PROVIDED BETWEEN THE GARAGE w w IN THE AIR BARRIER WITH CAULK OR FOAM LI_ C. LIGHT FIXTURES MUST BE LCAT LABELED. 2X4 INTERIOR INSTALLATION(INCL. BOXES, PIPES AND � ►- Puildin envelope a5sembl ie5 that are art of the alteration shall com I with PRIOR TO FINAL INSULATION INSTALLATION(EX. g p p p y AND CONDITIONED SPACES. LIGHT 't' FAN 5 EALS ALL CABLES). BOXES, PIPES AND CABLES). 5ection p402,1,2 or 1:402,1 A Sections M02,2,1 through 1?402,2,12, P.ECE55ED LIGHTING RECESSED LIGHTING FIXTURES INSTALLED IN THE BUILDING RECESSED LIGHT FIXTURES INSTALLED IN THE BUILDING TOP PLATE/ATTIC DETAIL '90f FIT D ETAI L THERMAL ENVELOPE SHA;; BE SEALED TO THE DRYWELL. THERMAL ENVELOPE SHALL BE AIR TIGHT AND IC RATED. 1/2"=1'-0" I?4025,1, 1?402,'5,2, 1:402,45 and I?402,�,�, A. INSTALL INSULATION WITHOUT M15ALIGNMENT5, 1/2"=1'-O" (AT EXTERIOR WALL) 1/2"=1'-0" PLUMBING 4 WIRING BATT INSULATION SHALL BE CUT NEATLY TO FIT AROUND \ WIRING AND PLUMBING IN EXTERIOR WALLS,OR INSULATION COMPRESSIONS,GAPS OR VOIDS IN ALL INTERIOR A. INSTALL INSULATION WITHOUT THAT ON INSTALLATION READILY CONFORMS TO AVAILABLL EXTERIOR WALL AND BAND J015T CAVITIES AND IN MISALIGNMENTS, COMPRESSIONS,GAPS OR EXTERIOR INTERIOR SPACE SHALL EXTEND BEHIND PIPING AND WIRING. CONTACT WITH ALL SIDES OF THE CAVITY. VOIDS IN ALL WALL AND BAND J015T CAVITIES. Exception; 1'he followinq alterations need nct comply with the requiremA5 for new qtu TREATED SILL ILL SEAL 4 SHOWER/TUB ON EXTERIOR THE AIR BARRIER INSTALLED AT EXTERIOR WALLS ADJACENT EXTERIOR WALI5 ADJACENT TO 5HOWER5 AND TUBS SHALL B. BACK WITH RIGID AIR BARRIER OR OTHER B. BACK WITH RIGID AIR BARRIER OR OTHER CAPILLARY BREAK construction provided the energy use of the build incl is not increased. WALL TO SHOWERS AND TUBS SHALL SEPARATE THEM FROM THE BE INSULATED. SUPPORTING MATERIAL TO SEPARATE THE p SUPPORTING MATERIAL TO SEPARATE THE FLASHING C. SLAB EXTERIOR FROM THE INTERIOR SPACE. GARAGE FROM THE INTERIOR SPACE. SHOWER AND TUBS. 0 p GRADE IGID INSULATION nc GARAGE %:"" OISTURE BARRIER ELECTRICAL 4 PHONE BOX ON THE AIR BARRIER SHALL BE INSTALLED BEHIND ELECTRICAL C. SEAL ALL SEAMS, EDGES,GAPS AND HOLES IN z C.SEAL ALL SEAMS, EDGES, GAPS AND HOLES RIGID INSULATION % OMPACTED FILL 1,5torm windows installed over exi5tinq fenestration, EXTERIOR WALLS OR COMMUNICATION BOXES OR AIR-SEALED BOXES SHALL z_ THE AIR BARRIER WITH CAULK OR FOAM PRIOR TO _ IN THE AIR BARRIER WITH RATED CAULK OR BE INSTALLED. C FINAL INSULATION INSTALLATION(EX.BOXES, FOAM PRIOR TO FINAL INSULATION 2,�xbtinq ceiling, wall or floor cavities exposed Aurinq construction provided that PIPES AND CABLES). INSTALLATION (EX. WIRING BOXES, PIPES AND B CABLE PENETRATIONS). HVAC REGISTER B00T5 HVAC REGISTER BOOTS THAT PENETRATE BIOLDING B D. SUPPORT INSULATION WITH STAVES OR •--'' these cavities are filled with insulation, THERMAL ENVELOPE SHALL BE SEALED TO THE 5UBFLOOR V. t�«5 OR DRYWALL. NETTING. VAPR BARRIER TO FACE PROPERLY. ' D. SUPPORT INSULATION WITH STAVES OR ',Construction where the exl5tinq roof, wall or floor cavity i5 not exposed, NETTING. VAPOR BARRIER TO FACE PROPERLY. LAB I N 5 U LAT I O N DET CONCEALED SPRINKLERS WHEN REQUIRED TO BE SEALED,CONCEALED FIRE E. INSULATION BAFFLE; I"MINIMUM, INSULATION * % NOTE-AIR BARRIER AT GARAGE MUST BE Y8" . t TO RETAIN 75%OF THICKNESS IN WALL BELOW. spoof recover, SPRINKLERS SHALL ONLY BE SEALED IN A MANNER THAT 15 +3 ,. q TYPE"X"GWB SEALED WITH RATED FOAM OR 112"= 1'-O" RECOMMENDED BY THE MANUFACTURER. CAULKING OR S?, +.K. CAULK. 5,Roofs without insulation in the cavity and where the 5heathinq or insulation 15 OTHER ADHESIVE SEALANTS SHALL NOT BE USED TO FILL VOIDS BETWEEN FIRE SPRINKLER COVER PLATES AND TYPICAL EXTERIOR WALL AIR BARRIER—GARAGE � exposed durinq reroofing shall be insulated either above or below the 5heathinq, WALLS OR CEILINGS. 6,surface-applied window film installed on existincl 5ingle pane fenestration (WITH VENTED CRAWLSPACE OR CELLAR) 1/2"=I'-O" 1/2"=P-O" a55embl ie5 to reduce sola heat gain provided the code does not require the glazing v or fenestration a55embl q to be replaced, O N N O WANbn & � 1911