Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7839
1 5-6 7R39 To I IiN ; h f4ks ��'tc7c,i n roposa f-itl i h&j ops �G� �.� �� ��s�a� � � �U�r�n�. ►zjzriz3 d 9; a r Owner: Budds Pond Marina Inc File #: 7839 Address: 61405 Route 25 Code: Agent Info Gregory R. Alvarez Esq. Amato Law Group PLLC 666 Old Country Rd. Ste. 901 Garden City , NY 11530 Phone: 516-227-6363 Fax: 516-227-6367 Email: galvarez@amatofirm.com 24 Cori L y?'p �jo rp'Ioo G�? yes �- S-fw Via ' OFFICE LOCATION: (/ MAILING ADDRESS: Town Hall Annex �*OF S® Tjy® P.O. Box 1179 54375 State Road Route 25 Southold, NY 11971 (cor.Main Rd. &Youngs Ave.) Southold, NY Telephone: 631 765-1809 http://southoldtownny.gov COU NN°I`II,�� RECEIVED ZONING BOARD OF APPEALS �- P" rs 3'y%Tm Town of Southold DEC 2 6 2023 94- kVntfeYrSouthold FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF DECEMBER 21, 2023 ZBA FILE: #7839 NAME OF APPLICANT: Budd's Pond Marina,Inc., Wireless Communications Tower PROPERTY LOCATION: 61405 Main Road, Southold, NY 11971 SCTM# 1000-56-3-15 SEORA DETERMINATION: The Southold Town Planning Board, as Lead Agency, at the conclusion of their coordinated review, has classified the proposed Action as an Unlisted Action as it does not meet any of the thresholds of a Type I Action, nor does it meet any of the criteria on the Type II list of actions; and pursuant to 6 NYCRR Part 617.7 of the State Environmental Quality Review Act (SEQRA) on December 18, 2023. Moreover, the Planning Board determined that the Action will have no moderate to large adverse impacts to the environment, and adopted the Negative Declaration on December 18, 2023. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23,and the Suffolk County Department of Planning issued its reply dated August 21, 2023 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. LWRP DETERMINATION: This application was referred for review under Chapter 268, Waterfront Consistency review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. The LWRP Coordinator issued a recommendation, dated November 20, 2023. Based upon the information provided on the LWRP Consistency Assessment Form, as well as the records available, it is recommended that the proposed action is CONSISTENT with LWRP policy standards and therefore is CONSISTENT with the LWRP. PROPERTY FACTS/DESCRIPTION: The subject property is a non-conforming 41,346 square foot parcel located in an MII Zoning District. The parcel measures 200.00 feet along Main Road, measures 226.51 feet on the West side, measures 199.09 feet along the North side, and 189.79 feet on the East side. The Northern side of the parcel is bordered by the Long Island Rail Road. The parcel is improved with a high one-story metal building. All is shown on a survey by Stephen F. Rann, L.L.S. last revised October 24, 2018. BASIS OF APPLICATION: Request for Variances from Article XIII, Section 280-53; and the Building Inspector's August 9, 2023, Notice of Disapproval based on an application for a permit to construct a new wireless telecommunications facility; 1) having less than 160,000 sq. ft. as required for a second principal use (80,000 sq. ft. per principal use) in M1I Zoning District where a principal use as a marina with boat storage already exists;2) located less than the code required minimum rear yard property line setback of 25 feet; 3) more than the code permitted maximum lot coverage of 30%; located at: 61405 Main Road, Southold,NY. SCTM#1000-56-3-15. Page 2,December 21,2023 #7839,Budd's Pond Marina SCTM No. 1000-56-3-15 RELIEF REQUESTED: The applicant requests variances to construct a new wireless telecommunications facility requiring the following relief: 1)the wireless communications facility will constitute a second principle use on the M1I parcel which requires 80,000 square feet per use. This parcel has 41,346 square feet therefore it only has the square footage to accommodate one principal use; 2)the Bulk Schedule requires a minimum rear yard setback of 25 feet where the applicant proposes a rear yard setback of 8 feet; and 3)The applicant proposes a non-conforming lot coverage of 32 percent where the bulk schedule permits a maximum lot coverage of 30%. AMENDED APPLICATION: The applicant, on August 9, 2023, submitted a site plan depicting a decrease in the proposed lot coverage to 28.2%, therefore, eliminating the need for one variance, and bringing the plan into more conformity with the codes. ADDITIONAL INFORMATION: Testimony was taken and evidence presented at the public hearing that the cell phone service in Southold is very poor and that this proposed cell phone tower will fill an important communication need for the people of Southold and provide essential communications support for first responders in the Southold Fire Department. FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on October 5, 2023 at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property and surrounding neighborhood, and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following'findings: 1. Town Law &267-b(3)(b)(1). Grant of the variances will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The neighborhood consists of marina businesses,boat docking, boat storage, restaurants, and a hotel. The construction of a cell phone tower will not adversely affect the character of the neighborhood. The Long Island Rail Road borders the rear of the parcel and the train tracks will not be affected by the proposed non-conforming rear yard setback. Beyond the tracks is open preserved land. The existing large metal storage building will block most of the tower and the cell tower compound from public view along Main Road. The proposed cell phone tower is a passive use that will not increase traffic on the property or on Main Road. 2. Town Law 4267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The applicant has an existing principle boat storage and maintenance business on the subject parcel, and the parcel is not large enough to permit a second principle use as of right. Therefore, any proposed additional use will require the benefit of variance relief. There is an existing large metal boat storage building on the parcel leaving the rear yard as the only possible location for a cell tower, and, based upon the required size of the cell tower compound and the subject rear yard, the applicant must seek variance relief for the rear yard setback. 3. Town Law §267-b(3)(b)(3). The variance granted herein for the non-conforming rear yard setback is mathematically substantial, representing 68% relief from the code. The variance granted herein for the non- conforming second principle use on the property is mathematically substantial representing 100% relief from the code. However, the proposed cell phone tower project area will only occupy 5.9% of the subject property, and will have no adverse impact on the existing railroad tracks or preserved land adjacent to the rear of the property. The installation of Southold Fire District communications antennas in the proposed concealment pole along with antenna of multiple wireless service carriers within the pole, will promote co-location and obviate the need for multiple tall structures throughout the community and greatly improve emergency response services and general cell phone use in the area. Page 3,December 21,2023 #7839,Budd's Pond Marina SCTM No. 1000-56-3-15 4. Town Law &267-b(3)(b)(4). No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code and the Southold Town Planning Board,as Lead Agency, has issued a Negative Declaration for the proposed project. 5. Town Law &267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law &267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a cell phone tower while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-13,motion was offered by Member Dantes,seconded by Member Planamento,and duly carried, to GRANT the variances as applied for, and shown on the Site Plan and Engineered Plans prepared by Jeremy K. McKeon, LPE, labeled Z-0I-Z18 and last revised June 15,2023. SUBJECT TO THE FOLLOWING CONDITIONS: 1) ,The applicant requires site plan approval from the Southold Town Planning Board. Failure to do so may render this determination null and void. This approval shall not be deemed effective until the required conditions have been met.At the discretion of the Board of Appeals,failure to comply with the above conditions may render this decision null and void ' That the above conditions be written into the Building Inspector's Certificate of Occupancy, when issued. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. IMPORTANT LIMITS ON THE APPROVALS) GRANTED HEREIN Please Read Carefully Any deviation from the survey,site plan and/or architectural drawings cited in this decision, or work exceeding the scope of the relief granted herein, will result in delays and/or a possible denial by the Building Department of a building permit and/or the issuance of a Stop Work Order, and may require a new application and public hearing before the Zoning Board of Appeals. Any deviation from the variance(s)granted herein as shown on the architectural drawings,siteplan and/or survey cited above, such as alterations, extensions, demolitions, or demolitions exceeding the scope of the relief granted herein, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code,other than such uses,setbacks and other features as are expressly addressed in this action. Page 4,December 21,2023 #7839,Budd's Pond Marina SCTM No. 1000-56-3-15 TIME LIMITS ON THIS APPROVAL: Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured, and/or a subdivision map has not been filed with the Suffolk County Clerk,within three (3)years from the date such variance was granted. The Board of Appeals may, upon written request prior to the date of expiration, grant an extension not to exceed three (3) consecutive one (1)year terms. IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO ENSURE COMPLIANCE WITH THE CODE REQUIRED TIME FRAME DESCRIBED HEREIN. Failure to comply in a timely manner may result in the denial by the Building Department of a Certificate of Occupancy, nullify the approved variance relief, and require a new variance application with public hearing before the Board of Appeals Vote of the Board: Ayes: Members Weisman(Chairperson), Dantes, Planamento, Acampora and Lehnert. (5- 0) Leslie Kanes Weisman, Chairperson Approved for filirig 1,),/ /2023 PROJECT TEAMa h GENERAL NOTES CLIENT REPRESENTATIVE - THE FACIUTY IS UNMANNED AND NOT FOR HUMAN HABITATION A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE 0 MAINTENANCE THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE;NO SANITARY c COMPANY ELITE TOWERS LP. ♦ -3 SEWER SERVICE POTABLE WATER OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED. ADDRESS. 15 DURKEE LANE _ M1 CITY.STATE➢P. E PATCHOGUE NY 11772 CONTACTTANYA NEGRON PHONE (516)410-8730 APPLICABLE BUILDING CODES&STANDARDS u E-MAIL TANYANEGRON@ELITE-TOWERS.COM g{'�.�t` �,•�yP gyAZIMUTH SITE ACQUISITION �0 Y_ Ig'}, g ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE ENGINEERING P.C. ELITE .7 O BBE A _ JI�.A FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES NOTHING IN THESE PLANS IS TO BE CONSTRUED TO COMPANY ELITE TOWERS LP. PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES ADDRESS. ISDURKEELANE Wireless Communications Infrastructure Experts CITY.STATE ZIP. E.PATCHOGUE.NY 11772 I. 2020 BUILDING CODE OF NEW YORK STATE(IBC 2018 WITH AMENDMENTS) CONTACT: TANYANEGRON PHONE 516 410.6730 2 NATIONAL ELECTRICAL CODE NFPA 70-17 E-MAIL TANYA.NEGRON@ELBE-TOWERS.COM ELITE1TOA/LRS LP Arek�s Cmn+wzaaona lxrb w:wre nPFa 3.2020 FIRE CODE OF NEW YORK STATE(IFC 2018 W1TH AMENDMENTS) ` 1 ENGINEERELITE SITE ID♦ ALBERTS ON MARINE ♦ 4 UGHTNING PROTECTION CODE NFPA 780-2017 COMPANY: AZIMUTH ENGINEERING P.C. ADDRESS: 90 E.HALSEY ROAD,SURE 104 S.AMERICAN CONCRETE INSTITUTE 318-14 - CITY,STATE ZIP. PARSIPPANY.NJ 07054 CONTACT: JEREMY MCKEON 6 AMERICAN INSTITUTE OF STEEL CONSTRUCTION ISTH EDITION E 1 - PHON973-970-0068 n •+�.�1�(� -t 7 9A/TIA-222 REVISION H I ;SOU ROde� E-MAIL JMCKEON@AZIMUTHEG.COM — - - 8 TIA 607 FOR GROUNDING 9 INSTITUTE FO0.ELECTRICAL AND ELECTRONICS ENGINEERS 81 A COMPANY: TlLESSEE VERIZON WIRELESS ' COMPANY: ESTE PIKE TOWERSLP. ID.IEEE C2 LATEST EDITION ,±p ADDRESS I S.DURKEE LANE II TELCORDIAGR-127512 ANSI TI.311 CITY,STATE ZIP E.PATCHOGUE NY 11772 I CO-APPLICANT 1 COMPANY. NEIN YORK SMSAUMITEDPARTNERSHIP SITE NAME: SOUTHOLD 4 d/bh VERIZON WIRELESS ♦ PROJECT DESCRIPTION/SCOPE OF WORKOn� ADDRESS 4 CENTEROCK ROAD CITY,STATE ZIP. WEST NYACK NY 10994 THIS PROJECT WILL BE COMPRISED OF: CO-APPLICANT ELITE TOWERS: l ' INSTALLATION OF NEW EQUIPMENT COMPOUND,6'-0-HIGH CHAIN UNK FENCE IST f PNITED�TYouNonr..m+ , COMPANY: SOU OLD FIRE DISTRICT r' CONCEALMENT TOWER MESA CABINET,ELECTRIC METER BANK,ELECTRIC TRANSFORMER ADDRESS SOUTHOLD. ROAD SOUTHOLD FIRE DISTRICT STEEL&CONCRETE BOLLARDS,LANDSCAPING&SHRUBBERY CITY.STATE.ZIP SOUTHOLD,NY 10994 • NEW 70'-0-x35'-0'EQUIPMENT COMPOUND WTH 6'-0'CHAIN LINK FENCE=1 I Call Eeron yoo da I • NEW ISO'CONCEALMENT TOWER=I FOR SPATE SPEOFlC DIRECT PHONE NUMBERS SHEET INDEX MESAC BC MN9T: METER BANK= MwW.CAuet1.CDM • ELECTRELECTRIC TRANSFORMER=I SHEET NUMBER DESCRIPTION STEEL&CONCRETE BOLLARDS=4 AS SHOWN —WAS JKM • NEW TREES,SHRUBBERY,LANDSCAPING=T.B.D. � Z-0I TITLE SHEET 61405 MAIN ROAD SOUTHOLD 14Y FIRE DEPARTMENT 9 06/152ED 3 REVESPER COMMS IRF JWS -ED 0$/1823 ED PER COMMENTS JCM JWS Z-02 SITE PLAN&NOTES NEW FIRE DISTRICT EQUIPMENT CABINET=I 7 05/0523 REmED PE0.cmMnENrs RF 1 Z-03 BULK TABLE 1 NEW FIRE DISTRICT PREFABRICATED EQUIPMENT PLATFORM=I J JWS Z-04 ZONING INFORMATION SOUTHOLD, 1197 y NEW FIRE DISTRICT CONCRETE%E0.=4 5 0411323 RINIsECUErrD PERCOMMENTs C JWS NEW FIRE DISTRICT ANTENNA-I Z-OS 200 RADIUS PLAN NEW FIRE DISTRICT PTP � 5 01!0323 cuENr connENrs )CM JWS Z-06 VICINITY PLAN VERIZON WIRELESS. I 4 ILI422 CIEWr COMMENTS WPK JWS 3 06/0122 CUENrconnENrs gWPKJWSZ-07 SDO'PROPERTY OWNERS UST INSTALLATION OF NEW 2'-0'0 CONCRETE PIERS,20'-0-x 10'-0•STEEL EQUIPMENT PLATFORM, y 2 05/1022 cuD4r connENtt Z-OB COMPOUND PLAN SUFFOLK COUNTY EQUIPMENT CABINET,BATTERY CABINET,TELCO CABINET,PPC CABINET,WORK LIGHTS. 1 DISCONNKTSWITCH,CABLE BUDGE PANEL ANTENNAS,RRH'SB DIPLIXERS. I 04/0521 CUEM COMMENTS Z-09 EQUIPMENT PLANZ-10 ANTENNA PLANS&ANTENNA SCHEDULE DRA NEW 2'-0.0 CONCRETE PIERS=6 REV DATE DESCRIPTION SITE TYPE. NEW BATTERY CAB STEEL T EQUIPMENT PLATFORM=1 Z-II ELEVATION NEW EQUIPMENT CABINET=I NEW Z-12 CONSTRUCTION DETAILS-I NEW TELCO CABINET I Z-13 CONSTRUCTION DETAILS-2 �1 l NEW PPC CABINET=1 NEW WORK LIGHTS=2 C Z-14 EQUIPMENT DETPILS-I NEW DISCONNECT SWITCH= ( ���/ K � O 150' 0" CONCEALMENT POLE NEW FIRM-3 PER ` 1� Z-15 EQUIPMENT DETAILS-2 / NEW PANEL ANTENNAS=2 PER SECT OR 6 TOTAL Z-I6 FIRE DISTPJCT EQUIPMENT-I NEW FIRM 3 PER SECTOR 9 TOTAL NEW DIPLIXERS=I PER RECTOR 3 TOTAL(AT EQUIPMENT) Z-17 FIRE DISTRICT EQUIPMENT-2 NEW TRIPLIXERR=I PER SECTOR 3 TOTAL(AT EQUIPMENT) Z-18 2007 INSURANCE FLOOD INSURANCE MAP AERIAL MAP VICINITY MAP NEW TRIPLIXERS=I PER SECTOR 3 TOTAL(AT ANTENNAS) N 0 RE YOR AREA OF WORK - ER-uc 9 -1 E Y AREA OF WORK SITE INFORMATION �m UOF u RDN D G UNDER PIREvN ! Igl VED F PROPERTY/TOWER OWNER 2� RECEIE1 Is I NAME BU DD'S POND MARINA INC _ ' S SITE II ADDRESS 61405 MAIN ROAD 26_ 1 - CITY,STATE➢P. SOUTHOLD NY.11971 +,+I AUG 0 9 2023 SITE NO:ALBERTSON MARINE DISTRICT: 1000 / ;.^- ISO SECTION 56.001 / - > y I 'O 61405 MAIN ROAD SUBJECT BLOCK/LOT: 3/I5 F- z Albertson Marine IF+c of Appeals SOUTHOLD,NY 11971 CONTIGUOUS Bo-1 "F Zoning Board SUFFOLK COUNTY LANDLORD-OWNED LOTS: 134,1,22 LATITUDE 41.076024 - a '- SITE TYPE: Q ^ti LONGITUDE: -72.406034 dao » 150'•0"CONCEALMENT POLE i LATILONG.TYPE NAD 83 F INAL MAP FEMA MAP BASE FLOOD ELEVATION= G AMSL I cOPYRICHTO)DU,AL61UIf1 EI:GWEEAP'G P.C.,LIG ALL 3 e ADMIlaII.D FOR USE wLY BY ll�PMIY FOR iNDY iNE v FAAIA GROUND ELEVATION= 5'AMSL ��� / _ - nos Gum uR'TNE OPPORM..D twTrNm HmnN rs 1 WED BY ZBA �A �:o�BE . �. �_ W EQUIPMENT ELEVATION= YABOVE GRADE - A 17�•/� 1fxJ DmF®uIm w FaTlm uvw FOR ANr oTFOR vuFaog N AREA OF CONSTRUCTION PROPOSED CONCEALMENT POLE&EQUIPMENT COMPOUND = O 1�E'(ir � V�O �T n¢Des wai1EN D�sHr of AmFU1N i waxE 0 P.G,uc l �] !31EET TITLE: ZONING/JURISDICTION. TOWN RI SOUTHOLD 26 DATED: I(/� =ESHEET ZONING DISTRICT: M-11-MARINE 11 - _ �l 25 EVV/ V p CURRENT USE/PROPOSED USE: UNMANNED TELECOMMUNICATION FACILITY -� FN- SHEET NUMBER ' K HANDICAP REQUIREMENTS. FACILITY IS UNMANNED AND NOT FOR HUMAN k rI m HABITATION HANDICAPPED ACCESS NOT REQUIRED. j OI Z-O 6 0 0 1. LOCATION AND ORIENTATION OF PROPOSED EQUIPMENT AND ANTENNAS PENDING n / STRUCTURAL ANALYSIS, N / 2. MOUNT ALL ANTENNAS, COAX, SURGE ARRESTORS, RRH'S, ETC. IN ACCORDANCE W I WITH STRUCTURAL ANALYSIS. Lb, s 3. TRUE NORTH BASED ON GOGGLE MAPS. Z I 'I PROPOSED 70'-0"x35'-0"EQUIPMENT 4 ENGINEERING P.C. _ NOT ALL EXISTING INFORMATION SHOWN FOR CLARITY. � -= - Y COMPOUND(SEE SHEET Z-08) FRESHWATER WETLAND BOUNDARIES DELINEATED BY VHB 5. SITE PLAN BASED ON SITE SURVEY BY AMERICAN ENGINEERING & LAND 9.8� 7'1n`'`_ ENGINEERING,SURVEYING, SURVEYING P.C. SIGNED BY STEPHEN E. RAVN P.E. L.S. LICENSE #49664 do ^ �ti111_-- '_--�___ -_--� o O LANDSCAPE ARCHITECTURE AND g,� _�� _- -__�!`_, Q DATED 10/24/18. ELITE T0�\'ERS LP �. - w O GEOLOGY,P.C.,ON MARCH 22,2023. 1 �„„�,,,•,. , _ \� w/ 6. FINAL UTILITY DESIGNS SHALL BE CONFIRMED WITH UTILITY COMPANIES. �IRRA�C S` 2.3 7. THE PROPOSED USE IS FOR TELECOMMUNICATIONS AND IS NOT INTENDED FOR 1, 5- �---_ --__ -__ - - ____ o__* W_BOT.OF PERMANENT EMPLOYEE OCCUPANCY. THEREFORE, POTABLE WATER. SANITARY ! ' IF4.5a x•59 47�e= �-- _ _ -`=__* _' F~= --`� NAL ON-SITE PARKING ARE NOT REQUIRED. - l 3___ _ y -- o =� SEWERS AND ADDITIONAL 154-0t __- -_--�'II^__ U- °' U B.fr�. 1Z ,ti:�7.�4���70i'Y• TO NEAREST BUILDING NAD ACENT PROPERTY OF SC0FE�` -- - -�_ti_-~� w 2��--_`--- _--_ B. THE FACILITY SHALL BE VISITED ON THE AVERAGE OF ONCE A MONTH FOR 6.1 1 _ ZU_ 0-11,15 -e;--_ MAINTENANCE AND SHALL BE CONTINUOUSLY MONITORED FROM A REMOTE 4 4_ _ 1 ie3 FACILITY FOR BOTH FIRE AND INTRUSION.4.6 e0'0., Ogg o- '_-- --_�--= `-H3 9. ALL MATERIALS, WORKMANSHIP AND CONSTRUCTION FOR THE SITE " To FENCE coMPOUND IMPROVEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH: 4.7 c0 To CONCEALMENT POLE 4.4 4.3 - = A. CURRENT PREVAILING MUNICIPAL AND/OR STATE SPECIFICATIONS. STANDARDS 011°� N I c �- AND REQUIREMENTS. ++++++ N 4.5 35 --_- B. CURRENT PREVAILING UTILITY COMPANY AUTHORITY SPECIFICATIONS. ! `A� STANDARDS AND REQUIREMENTS. 4. ��,x m 0� I ^ MG�VVL 10. CONTRACTOR SHALL CONTACT 'NEW YORK UNDERGROUND PLANT LOCATION ry �I.Y_1+ry m � f ; PROTECT YOURSSE� D _ \ 00 LIMITS OF NYSDEC FRESHWATER SERVICE* AT 1-800-962-7962, AND LOCATE ALL EXISTING UTILITIES WITHIN r c� 4.4 WETLAND 100 FOOT ADJACENT THE AREA OF WORK PRIOR TO THE START OF ANY EXCAVATION. e1Dw. ��»n.a• P.., ? v `•++E44� 1 I AREA AND TOWN OF SOUTHOLD Call e.w°p.as �= z I 46 +�+ rON�1 WETLAND JURISDICTIONAL AREA 11. CONTRACTOR SHALL COORDINATE AND COMPLY WITH EXISTING UTILITY 0 5AEMST. w Iiro�i RuueEs I m ; ®+ RF I COMPANIES REQUIREMENTS. ca - 3'T 4Sp_ ..s�'! u.IE.: -____T_ar: _¢ 1 �NrF 0 ® AS SHOWN ° WASKM Y RS 12. UNDERGROUND ENCROACHMENTS. IF ANY, ARE NOT SHOWN. J F 0: 47'- (/j ® 9 06/15123 RI-m I'm COMMEN JRF JWS m p"t 3.g Oq� 13. ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES ARE TO BE RESTORED TO B 05/18/23 REVISEDPERCOMMENTS JCM JWS 70 FENCE COMPOUND , PRE-CONSTRUCTION CONDITIONS. p 4.7 �� / �J ® ! 7 OSlo523 REVISED PER COMMENrs JRF JWS ' 86'-p'*' i o ! 14. THERE ARE NO WATER MAINS, SANITARY SEWERS, DRY WELLS. GROUND WATER 6 04,1323 REV SED PERCOMMEN S WS JRF _z ro CONC RECHARGE BASINS, OR DETENTION BASINS PROPOSED FOR THE PROPERTY. s 0101103M a EN MEN s o3 Com JcM Jws CONCEALMENT O Q I C N 1 4 12/14/22 CLENr COMMENTS WPK JWS GRAVEL HIGH 1 STORY I 15. No SIGNALS. SIGNS oR TRAFFIC CHANNELIZATION OR PUBLIC ROAD METAL BUILDING °z I ✓ I m� 1 3 0610122 CUENTCOMMENn WPK JWS z 74,56 I _ w IMPROVEMENTS ARE PROPOSED. z ® Z ;#61405 •- 2 05/1022 NENTCOMMENTS JCM JWS 5 4.7 n w O- o z y ®® 16. THERE ARE No PROPERTY DEDICATIONS PROPOSED. o4,os121 cu NTcanMEN s cM Jws I 4.4 - U +I F 4.3 - t¢ ® REV DATE DESCRIPT °qi T"" "g 4.3 0 I 41 ® 17. NO TEMPORARY OFFICES OR STRUCTURES ARE PROPOSED FOR THE SNE. �At OF NYSDEC FRESHWATER p Z `°C.- LIMITS /r 18. THESE DRAWINGS ARE PROVIDED FOR ZONING APPROVAL CONSTRUCTION LEVEL 1^1 WETLAND 100 FOOT ADJACENT o / DRAWINGS WILL BE DEVELOPED SUBSEQUENT TO THE APPROVAL OF THESE S REA AND TOWN OF SOUTHOLD LLO I I a EFLAND JURISDICTIONAL AREA F 4.0 ® DRAWINGS. * K cfi !.P� ® 19. SITE PLAN BASED ON SITE SURVEY BY AMERICAN ENGINEERING & LAND a 4I I w ® SURVEYING P.C. SIGNED BY STEPHEN E. RAVN P.E. L.S. LICENSE /49664 &I ® DATED 10/24/18. r'3 4.25 FF4.3 GF4.64 +` N ! / N I 424 4.44 p(M• o e N 71 N 2 061 4 4p.7' 4 N ' R CEgly6� OFE590N 4.21 `` / M �`�-- ® / I NR6C.� iB� 374-1 IT IS ATH n FgOERR1ANY P / CONC. /SPH., ' NLES 378 OF THE RESP N SED 7F3.71 PROF N•N . _ ___ __ ,% ® �- . -_ 7 V ENGINET7t, THIS DOCUMENT ! \ ` RECEIVED SITE INFORMATION 3.68 EA 3.65 3.39 7 EA 51 SITE NO:ALBERTSON'MARINE sa�•zs'2�''w------_4--_ _ 200.00' ® 'F3.50 a AUG 0 9 2023 (S58-31'00"61) - __ % NAL N!A P 61405 MAIN ROAD 4.33 4.26 D11 y 4.10 ` --- 3.95 3.98 D% ____X4.03 COORDINATE SYSTEM:NADS /�J SOUTHOLD,NY 11971 e e (2001)NY SP FEET LONG ISLAIJ ��! ` w /r® ��/ Z RA / ® 0 ! 1,@/lV/C i LJ SUFFOLK COUNTY MAIN ROAD (N.Y.S. RTE. 25) I _-1IS�� Zoning Board of Appeals 9, `® l n C C I S I O N# SITE TYPE: L1!� �3 I�E 150'4"CONCEALMENT POLE Win¢wF��,Ae nw mxr•nm"Dmx s 613 _77 ; �� "�TNm�ian Lig oar er rxE vARrc FCR•Rol rI¢ II v rAs oamuclm oR ro•xa.Ir a omTPrta n.s oRArwc MAr ROT eE mr"m,,ausn.wzaosn. UNDERGROUND SERVICE ALERT-NEW YORK 811 rc aT'En,E Dwa6suP°"Tm,'OPm`�"m°T"�or w FRESHWATER WETLAND Ervmamwc P.a a1< n: BOUNDARIES DELINEATED BY VHB UTILITY NOTIFICATION CENTER OF NEW YORK • ENGINEERING,SURVEYING, (800)272-4480 LANDSCAPE ARCHITECTURE AND WWW.NEWYORK-81LCOM /��¶ ' i RGEOLOGY,P.C.,ON MARCH 22,2023. Know what's below. SITE PIAN 612 NOTES m CALL 2 WORKING DAYS UTRM NOTIFICATION PRIORTO CONSTRUCTION Call before you di. ol ^ 12 20' lo' 0 20' 41'SCALEOR 22°x74"DRAWII.GSSHEET MIMBER n-02 1 SITE PLAN °"" - SC .LE.12"•ia•-0"FOR 1I^x17"DRA%MGS a REQUIREMENTS OF CHAPTER 280-70 ZONING ARTICLE XVII WIRELESS COMMUNICATIONS FACILITY 'D CODE SECTION DESCRIPTION COMMENTS �g j 0 ,.j LQMPLESEVEDFTION(1)�T ASBREB OVOEME h 386]00(t) ;ATDry OF WREIESS FACLITES FURTHER REVIEW DFPRIORm RANKINGION PS PART OF MPLICATON SUBMISSION N 30670E MENNASUPPORT STRUCTURES PRE PROHIBITED COM>UEB 286]0 F. AMEM4ASUPPORT STRUCTURES SH4L NOT BE LOCATED WTHE FOLLOWNG AREASWRTHOUTAPERMT FRO MALL.TDA-CTIONALPGENLIES: AZIMUTH 3�6]0F 1 LPNDS,TDAL MD FRESLMlATER COMPLIES 2967I F :OUND Yn RHN IO FEET OF THE SURFACE COMPLIES 380.70 F ,ED WITH COMMMITY PRESERVATON FUNDS. COUPLES 38670E 4 ASTAl.ER...NHAZARD MEAS COMPLIES EN CBI.EERINO P.C. 28670E C51 DESIGNATED PARKLAND. Co-.Es FALL IDNES.ANANTENNASUPPORT STRUCTURE MST INCLUDE ANAREASURROUNDWG R THAT S FREE OF OTHER STRUCTURES AND AREM WHERE PEOPLE CONGREGATE,E%CEPT THE BASE EQUPMENT,VVITl1 A )�'> RAD NS EQUAL TO A DSTMCE OF TWO TINES THE HEGM OF THE STRUCTURE ASMALLER FN.LZONE MAYBE «T 300'FALLIDNE REQUIRED,A''-0'FROM NEMEST PLLOWE TURALEFSUPPORTEPORT SMALL B SUBMITTED B OA AND REVIEWED BCTURAL ENGINEER.THE STRUCTURE ON PROPERTY,STRUCTURAL REPORT 2BD70G STRUCTURALENGMEER'SREPORTSMPLLBESUBMTTEDTOANDREVEWEDBYTHE =N-GBOMDMD PROVDEDASPART OFAPPUCATONSUBMSSON ELITE,TONrERS LP CORROBORATED BYAN NDEPENDENT CONSULTANT HARD BYTHE TOWN THAT DEM)NSTRATES THATA yARIANCE REOUREp mvnan<el t'�s e:rmw.w�BR_ SMLLLLER FALL MNE 6 MPROPRWTE PND SAFE TME FPll ZONE OF AN ANTENNASUPPORT STRUCTURE MJST NOT INCLUDE AREAS WHERE PEOPLE CONGREGATE,AND MUST BE CLEAR OF ALL STRUCTURES EXCEPT THE BASE STATION EQUIFMENT AMENNASUPPORT STRUCTURES IN THE LU UO,M MI,B.AND HE 20NNG DISTRICTS ME SUBJECT TO THE 2B67oL f`�`�" FOLLOWING RESTRICTIONS '� _ t >:. 280.701(1) )RDWCEWITHTHEBULKGCHEDLIEFOR EPCHZONE E%BTWG NONCOMPLJNlT MHMINIMIMLOT-80,000 �, `Tr i- 1 SF EXISTING LOT G 41,3W SF - - PROPOSED MONOPOLE HEGM'150d '• � Ii,THOLD-#- 380.]01(3) MPXLMUM HELM 80 FEET. � ' - VARW4CEOR WAIVER REpUIREO 1 200.]01 MNCJLM DBTANCE OFPLL WRElEbS ELBE OMIESA:EMRESOEMW.PROPERTY LINES OR STREETS L y,l �) SINLL BE IU LESS THAN 500 FEET k-0-TO ADJACENT PROPERTY LIVE SITED CNI STANDARDS ALL WIRELESS FPGLRES,NCLUONG OO-LOCATIONS.SMALL BE THE LEAST VSUAl1Y 2B0.70N OBTRUSIVE DESIGN POSSIBLE THAT ALSO PERMITS THE APPLGAM TO ACHIEVE RS SERVILE NEEDS TO THAT END,THE FOLLOWING DESIGN STANDARDS SHALL APPLY TO ALL WIRELESS COMWUNK:ATION FACILITIES NSTALUED O R CONSTRUCTED PURSUANT TO THE TERMS OF THS CHAPTER _ SETBACKS ANTENNA SUPPO RT STRUCTURES AND EQUPMEA T—CITES SHALL ADHERE TO THE SETBACKS O� 280.70N(1) FOR PRINCIPAL USES IN THE BULK SCHEDULE APPLICABLE TO THE ZONE IN WHICH THE STRUCTURES ME (REFERTOBLLKREQUIREMENTS CHMTONSHEETZ- LOCATED.UNLESS OTHERWISE INDCATED ELSEWHERE IN THIS CHAPTER 03) SIGNS SIGNS SHALL NOT BE PLERMRTED ON FPDLITES EXCEPT FOR SIGNS DISPLAVPIG CONTACT NFORMATION ANDSAFETYNSTRUCTIO ., LHMEREQNRDG EIYSGNSSHALLBENACCORDANCEWITXAMERCAN SITE WFDRMATON SIGN PAD RF SAFETY SIGNS TO BE 286]0.p) NATONL STANDARDS NSTITUTE(A I)STANDARDS FOR RADIO FREQUENCY RADIATION WARNING SIGNS. INSTALLED ON EXTERIOR OF COMPOUND FENCE PROTECT YOURSELF CONTACT SIGNS SHALL IDENTIFY All SERVICE PROVIDERS LOCATED ON TFC FACILITY AND SHALL ALLUDE NORI—AND EMC-RGENCYCONTACT NFORMATION FOR E' SUCHSGNESH4 NOTEXCEEDFNESQUME COMPLIES FEET N SURFACE AREA _elow. BULK REQUIREMENTS FOR ZONE M-II (MARINE II) BASE STATION EQUIP NENTSHOLTER.TIC-BASEUCTIJRD FS NTHEPRHELTER AND INTEGRATED ITOTH WITH FOR �kn Ew Cq A FNTI SIMILAR EQUA THAT WSHEFPDAAL-B SESILTONEQU W PROPERTY LTERS DOTE COAT INTO THE CA STATE SPECIgC ODER PHONE NUMBERS ARCHITECTURAL SME.ANY NEWLY CONSTRUCTED BASE EQUIPMENT SHELTER SHALL BE LOCATEDW VISIT:MWACALLBI1.Lp1 PDCORDANOE WITH THE MNIMUMHEGMANDYARD REQUIREMENTS OF THE ID DSTRICT_LIC NOSIELTERSME CURRENCY l i 386]0 N(3) PROPOSED.THIS WILL BE TAKEN INTO THE SRE,MOUP TO TWO ADIPCEM OFF-STREET PMKNG SPACES MAY BE PROVIDED FOMC ERVCE SCAB: pRAM1 BY: DEO®BV. I VEHICLES NOTWITHSTANDING THE FOREGDNG,BASE EQUIPMENT RELATED TO INTERIOR-MOUNTED CONSIDERATION UPON FUTURE PROPOSALS AS SHOWN WAS JKM DESCRIPTION REQUIRED EXISTING PROPOSED COMMENTS WREMSSFACILITESSMALLBE LOCATEONANMFATHTBSATBFPGTORYTOTHEPLMPM'GBOMDLPON LONSDERATDN OF.PACTS ONAOJACE W PROPERTES MD MANl10NG VSLNL O PACTS •, 9 06/1523 REVISED PER CCMVIENTS JRF JW$ MINIMUM LOT DIMENSIONS BASEEOUPMNTLMOSCARNG ASCREENOFEVERGREENTREESSHALLBE PLANTEDOLRSIDETH-Ec FENCE 8 0$11823 REV4EDPEA COMMENTS JCM JW$ AREA 160,000 SO FT• 41,346 SO FT ND CHANGE NON-COMPLIANT" OFTHE BASE EQUIPMENTAREAOR SHELTER TO PROVIDE AVSUALLSCREENOR BUFFER FOR ADJOIN.. WIDTH 150 FEET 200.00 FEET NO CHANGE COMPLIES PRIVATEPROPERTESAND THE PUBLIC RIGHT-0F-WAYOR OTHER VANTAGE POINTS ACCESSBLETOTHE EVERGREEN SCREENING TO BE PLANTED MOUND 7 05/0523 REVBED PER COMMENTS IRF JWS DEPTH 150 FEET 189.79 FEET NO CHANGE COMPLIES 3BD]ON(4) PUBLIC.THE SCREEN SHALL CONSST OFADOUEM ROWOF EVERGREDSHRUIBS AND TREES THAT ME OF FACILITY 6 04/1383 RFVBED PE0.COMMRF WS SUFFICIENT OENSRYAND HETO MUEONTELY SCREEN THE BASE EQUTPMEM FROMWEW REQUIRED ENTS I I MINIMUM YARDS FROM YARD SETE=KAREAS SMALL BE LANDSCAPED AND INCLUDE SHRUBS AND TREES SURVNABNTYOF COMPLCS ! 5 01/03/73 CUENTCOMMENTS CM WS FRONT 35 FEET ±29.4 FEET 174'± (TOWER) COMPLIES THEELMDSCMINGSHALLBEGUMAMEEDANDMVWR DBYTHEMPLIC—ORTHELFEDFTHE I I 1 NSTALLATION 4 17/14/22 CLEINTCOMMENTS WPK JW$ MINIMUM YARDS 86'± OWER SITELGKING THE LIGHTING PERMITTED SMALL BE THE M78M1M REQUIRED TO PROTECT THE PUBLIC 3 0610122 CLIENT COMMENTS WPK WS SIDE 25 FEET 40.7 FEET (TOWER) COMPLIES J REAR 25 FEET 61.9 FEET 30'± OWER WELFARE FT SESTES.SITEON EF SHALL BENCORFO (TOWER) COMPLIES ALMS OF THOSE SRES.OUiSDE LGMINGStNLL ISE FULLY SHIELDED FIXNRES 50 THAT THE LGM 7 05/1022 CLIENT COMMENTS ICM JW$ BOTH SID E$ 50 FEET 102.6 FEET 199'± (TOWER) COMPLIES 30P70N(5) SOURCE B NOT VISIBLE FROM BEYOND THE PROPERTY LME,MONO LGM B REFLECTED OR SHOIS COMPUES TOWARDS THE SKY,EXCEPT IN THE CASE OF STRUCTURES REQUIRED TO FOLLOW FAA GUIDELINES FOR I 04/0521 JCM JW$ MINIMUM YARDS SAFETY LGMNGE SIDE 25 FEET 40.7 FEET 47'± (COMPOUND) COMPLIES REV REAR 25 FEET 61.9 FEET B'± ((COMPOUND) NON-COMPLIANT•• STPNDMOS.NADDRGNTO THE STANDARDSNMTCLE XRNMDTME STMDARDSN§380.>O McgEN,ILLL L 80TH SIDES 50 FEET 102.6 FEET 127'± COMPOUND) COMPLIES MELESSFAC C-S,MLMNGCO-LOCATIONS,SHAILBETT-L TVSUPILYOBMUSWDESGN 380.731 POSSIBLE THAT ALSO PERMITS THE APPLICANT TO ACHIEVE ITS SERVICE NEEDS TO THAT END.THE (1)THROUGH(4)AS WELL AS(S)ME NOT MPULABIM FOLLOWING DESIGN STANDARDS SMALL APPLY TO ALL WIRELESS COMMINICNTION FACLLTCS.STALLED OR [1'1 LANDSCAPE AREA 20X MAX 0% 4.439. COMPLIES CONETRUICTED THAT REQUIRE SITE PLM MPROVAI_ 2%(NEW) COMPLIES CO-LOCATION WIRELESS COMAUNICATION FACILITES SHALL BE DESIGNED TO PROVIDE FOR CO-LOCATION BY MAXIMUM LOT COVERAGE 3DB 26.29. 26.29 TOTAL 286]31(5) MILTPLEPROVIOERSOROESGNEDSO THATTHEYCANBERETROPITTEDTOACCOMMODATEMLTPLE COMPLIES O PROVDERS,WHEREVERPOSSBLE y SCENIC LAMIDSCMES AND VSTAS.ALL AMENNASUPPORT STRUCTURES W"'H ARE NOT CONCEALED INSIDE - THE WIRELESS FACIUTY IS CONSIDERED A SECOND USE ON THE OF SMDNKS OR SCREENED BY EJ 4TWG TREES OR BILDNGS MLST BE SURROUNDED BlAlL LTED SITE NOT LOCATED N SCENIC VISTA SUBJECT PROPERN.THE TOWN CODE BULK SCHEDULE FOR THE 280.721(8) BUFFER OF DENSE TREE GROWTRMANTENNASUPPORT STRUCTURE TENT SLOOATEDWITHINASCENIC MII ZONE ROUIRT 80.000 HET W FT PER USE VISTAORSCENCLANDECMEOR WITHIN 300 FEET OF ASCEND ROAD,M DESIGNATED BY THE TOWN,SHALL COMPLIES NOT BE TALLER THAN 10 FEETMOVE THE HEGM OF TREES WRHNARADIOS OF 300 FEET OF THE PROPOSD LOCATION,OR S5 FEET MAXIAM IN THE ABSENCE OF TREES �n& COLOR ANTENNA SUPPORTSTRLOTURES WTFC FORM OF MJNOPOLESOR OTHER TOWERS SlVLLL EITHER BE BLUEGRAY IN COLOR OR BE COLORED MPROPRWTE TO THE CONTEXT OF THEE STRUCTURE'S LOCATIONSOTHATTHETOWERSAS DNOBTRUSIVEM POSSIBLE,UNLESS OTHERWSE REQUIRED EYTHE FEDERAL 386]31(]) AVWTIONADMNBTRATDN(FAA)IFAWRELESBCOMAUNCATIONFACLmGNSTALIM.-ASTRUCTIRECOMPLIES-TOWER TO BE PANTED BLUE-GRAY OTHER TIVN ATOWER,THE ANTENNA AND SUPPORTNG ELECTRICAL MID MECHANICAL ED UPMENT MUST BE OF A NEUTRAL COLOR THAT B DENTCAL TO OR CLOSELY CONPATBLE WITH THE COLORS OF THE ITIS 'OF ERSON, SUPPORTING STRUCTURE SO M TO MANE THE ANTENNAAND RELATED EQUIPMENT AS VISUALLYUNOBTRUANE UNLESS TING U E pREC110N AS POSSIBLE OF%REBPON SD PROFFS90NAL ENGINEER,TO ALTER THIS DOCUMENT. ANTENNASUPPORT STRUCTURES NOR AD3ALENTTO RESDENTLALIDNES WHBRETHESITEPROPOSEDFOR MANTENNASUPPORTSTR.%RESLOCATEDWITIQ.ARESDENTW M ORMASONEORMORE SITE INFORMATION: PERMITTED N ARESDENTNLOMN.MANTEOMJASUPPPPORTSTRLK RESMAYBECONSTRUCTEDUNLESS SITE NO:ALBERTSONMARINE A EQWTELYSCREENEDFROMVEINOFTHOSERESDEMU IDNESeYEXISTBGBUILONGSORLARGE TREES,INCLUDING EVERGREENS THE STRUCTURE MAY PROTRUDE NO MORE THAN 10 FEET ABOVE SCREENING BUILDINGS ANOIOR TREES IN THE ABSENCE OF AN ADEQUATE ARRANGEMENT OF EXISTING LARGE 61401 MAIN ROAD TREES OR B-08TO PROVIDE EFFECTIVE SCREENING,THE HEIGHT OF THE PROPOSED STRUCTURE MAV TSR E_ZC)n6ijn EIV ED BENO RARETHANEFEET,ES THEBASE OUIR.TED ENCMUSTBE E ETRC UUNDERGROUNDVAULT.TWOSOUTHOLD,1\1 11971 2&1311(9) ROWS OF MTREST UCTU ENTREES FTHEUST PLNIOFTE RLLMGTHESTRUCTURE,ON-RiSMT THEMCE TVJO ROM EUEFSO GHTAR EN TREESTO BE DED. DFROMTHESTRTC ETOF5096OFTHEHEESS FL ESTRUCTIJRE,ANDTICOTT.RET.%OFTHEHEGM RELIEFSOWMASTO HEGMAS NEEDED.OFTHEST RILETREESMUSTDTREESSNPLLHANEIMTATMCURITYOFTHREEINCEB,SPACEDSOSUFFOLK COUNTY FEET EI LEANER.THE TREES MLST HAVE M EXPELTEO HEGM AT MATURITY R ATIALST10 FEETLESSTHANTHEEE LATHESTRUCTURETOBESCREENEDSMALLEREVERGREENSHRUBSMUSTBEUSDTOTHEIN L,—NIIGBNBETW EN YVMY SCRERANG MENTOURING THETREHETNEES MESHRUGS OAC AND OMMODAMEI TMESITE TYPE: SITE NGBOARD.AND AC TIE MHMGE OALOFTHETREESTIESWltlTYTOACCOMSODATESPECRC SROCONDITIONS.MDACCOMPLSHTHF GOALOF SCREENINGTH-L FASO FROMVIEWOF QUIREDTO /�0 9 20� PROPERTESAWRRTENGUARPNTEEFEANDMEWATSNE THRYSMDUTTHHALLBENCEOFEDTO 110''V"CONCEALMENT POLE �� ENSURETH4T TIE PLMITNGS SURVNEANDMEMMANED THROUGHOUTTHEEXISTENCEOFTHE eatsbard bf App 281--4 ES$TRUCTURESANDZONWG WIT 500 FEET. 35S'JYTO NEAREST RESIDENTIAL PROP-ERN RGHISBERVD 286]40(5) LC E,TYPEAN_MT.FTFEW HNSMFEET+COMMUNICATION FPLLm (BEE SILET Z-01) 1H6 pNVUC NO NLME TpI CpITANDJ HpEL 6 AUTHaazm Fat ug ADR er W Pum Fpt rHOI THE .pa vAs Ia4mALTm DR ro aM Ir 1s pRatm THs A LISTN,OTHER CARRIERSALREADY LOCATED ONTHE FNEL WITH THE NUMBER,TYPE,HECK. OMMNO wY NOT BE WILD),REUSED,pSCLpSTD. OI 386]40(8) ORIEMATON,EFFECTIVE RADWTEO POWER,NUMBEROF CHANNELS ANDOPERATNG FREQUENCIES OF EACH (BEE SHEETS Z-14-2-1'>) pB1fuBJ1FB OR RI L".iOq ANY0B4R RRfk IMIIOUT THE FXPIS55 MATTER f-0Plglli 6 AL11UM W ANTENNA INCLUOSETHE D QlOtR�10 D: 206740 1 .THE PROPOSED FALLITY ANmANDTHE FOLLOWING P'L'LLL N 2M74 (10)(a) BAREST RESIDE—STRUCTURE 8744 28674 C.10 "PROPERTYLNE WITHARESDENTW.USE 35]4 SHEET TITLE: Z 380.740 10 c ALL OTHER STRUCTURES S74'a K 300.740 10 DS,RGMSOF-WAY.DRIVEWAYS 28674L(11) um NERADMSANDOBTANCE E - BULK TABLE Z 20674 C.(12) ROPOSED MEANS OF ACCESS I.` C) ELEVATIONDRAWNGSWRHDUENSIONSCLEMLYNDICATEO,MLWNGDWJC-TERyy'O WD T 2MNC.(13) STRUCTURE AT RS WDE$T ANO NARROWEST,AND TVE TALLEST POPR,INCLIDWGAMENNNS OR LOMNWG SEESHEETZII �SHEET NU48ER: PROTECTION Z-0r) ZRA3 Q DECISION# CANED: N �� 11.13, zzs h�p Albertson Ln �' zzb w Le ea ,1+ ��/ uDdv►ev' y�iN 4.2 z� 1 o s \ry 9r, W 7.0A - 10.1 o` c- Greenport h) ,,�,� \Z I M UTA- 1 _ 27.7A �0 ' Sage BlvdENGINEERING PC 1 TOWN OF rid \y I a S 11.16 SOUTHOLD 3.8A a ``rpt ELITE,TOWLRS LP � (COUNTY OF SUFFOLK _._ DEVELOPMENT RIGHTS) D _ o,� tr o_ FIRE 11.5 ,,� sl-E HamletCenter SOUTHOLD — 59T \ e LOCATION coning p •�. 6 y EP U!, Ot y o1>1 ZONING M 9• AC OUNTY OF SUFFOLK u / ag ati �, �i, G O rOsf� AHDverum jO DEVELOPMENT RIGHTS)` 4 B 1 A(c) N�'7t /. 3^ L�� e 3• HB ) .ate s PRDTEDT dR .= <'> �...�Tbw. �A HD Call eo,.r..eu ^ 135 13 43 ^ 2. RADIUS INE /� •�% -- `� � O LB FM STATE 9T:OwRw.CN1E11.0V DWC1-E RuuBERs ` Op'�ol '1 1.7 (c) o..a. . 1� 11.2 �a ^b1 �• ,� tars ,F :' \ LI AS SHOWN WAS JKM 1.4A / �' '?' X, ( F 9 GWISl13 RE�M1SEDPERCOMMENTS JRF Jws k1l - - LJO B 05/18/23 R EDPERCOMMENTS JCM Jws 1.2 1� — Ra _� 7 05/05(13 RNISEO ERCOMMENTS JRF JwS /' ,�• �' - -- - MI 6 0,/13/23 REED PER COMMENTS RF JM �! ^ 2.3A(c �yg�M aoutl�old l/�` \ 5 01103f23 CllEMCOMMENTS JCM JAS COU _ MII + 12/14r22 CLEINT COMMENTS WPK Jws FO/L� ckey--C-_r-, D'-r. d %� T 3 06/01127 CUENT COMMENTS wRR JwsOFS Ys .s Mile R-40 70 /2CUENT COMMENTS JcM Jws K losl <uE taec TCOMMENTS JCM Jws COUNTY R-$0 REV DATE DESCRIPTIONOF J/ - // ' Budd's Pond I Custer Ave RO Ila, u E[� r� CYC N Parish r RR �[ F /�E'}/ 1U yNDERWATER UND) T I �'C'r�+' _ A C. !� 1/ ,�r L!1- 17 8 �1 (01 -N C - �rsj`� ^4P //c^ 8 & Jtsl ^^016 o zDaOF r +3Ua t�0< y- ^ C _ ,. 50 \�y �/ � h • g 12.1 aN ^ N Bayview Rd Ext N Bayview Rd_ nE aT L,MTMr�ZE y� l r7�MOLE UD NSED TME jl ECEtyn!` 13.1 / Clbe >~ "/a aN� ETHISODP M� � JOS� � 1t„i eP r � _ V '�•1'Cn � �e � 'o fi' U y eKa� p SI RMATI t,z1 28 - ds R o ao a SITE NO:AL MARINE 2.5A(c) : v 10 40 "`53 ,,6 �. ` _ m ;.\�m a / 61405 MAIN ROAD N"AL1.eA(c oa•`z -,w' �f'Z1 (� 'Po J SOUTHOLD,NY 11971 yOZj �ge h 30 , tN� ti`0 y� JTy�r Q Y a SUFFOLK COUNTY ,�� SITE TYPE: RECEI� r _ t lg/» 150'4”CONCEALMENT POLE AUG0 9 2023 : `� �� � n COPYR GHi4IDSl AZAR i PPGWEFRDiG P C.. ALL Map Prepared by OTE: ,Ra oRAi.1c..o Au Tic.raw.Ra cal..lm RnoR a AVMWII➢f011 VSE plY 11'1NE PNRY fOR 1101111E W Np oRA'w W o°E�Wim. �? A Peals Town of Southold Geographic Information System a.�D m � T�µ•on•R P • N Zoning Board of P 1. PARTIAL ZONING MAP IS BASED ON ZONING July 29,20161 EROmMG P.a MAP PREPARED BY THE TOWN OF SOUTHOLD §uffolk County Rtgal Pmpw* gg�� s+EFr nna > 07/09/16.PC INFORMATION SYSTEM DATED urtITMMyc'M/-� ZONING INFORMATION "'SHEET euueot r\L1 PARTIAL TAX MAP G"^ "� N.T.S. 2 ZONING MAP " N. .SZ-04 fe.C`� . a — — r)ATE D : a ';i- _ a o • 0 V. n +' r j •~ 'a jW- P 7 • FRESHWATER WETLAND � � `� s',�, BOUNDARIES DELINEATED BY VHB ` �� E ENGINEERING,SURVEYING, � A /� ' • LANDSCAPEARCHITECTUREAND - • + : •r , GEOLOGY,P.C.,ON MARCH 29,2023. 14 ELITF� FRS LP '� FRESHWATER WETLAND r• r r 'ir_ �� . e �� i ��• t•': BOUNDARIES DELINEATED BY VHB - � jr � - �►" ENGINEERING,SURVEYING, `(' " � • � � � �R }"J.J'' � � 4 • LANDSCAPE ARCHITECTURE AND r• �'V C F F P.. i"�• GEOLOGY,P.C.,ON MARCH 29,2023. ;"`. ��' t ''�✓ SOUTHOLD �+• 5�` L i r.- s f � LIMITS OF CLEARING,GRADING WETLAND W2 + s �" �"� AND GROUND DISTURBANCE �S !O �w i . , . WETLAND . rw 34) _... • • r � .. • � PaoTECT rou"sElr • >. •� www 'call b,.�.eG. EOR STATE SPENEIC NRECT—E NUYEIERS - _• - ~ :' � � .f � �`� N4T:WWWCN1D11.001 t 1� ` • - GMM R DEO®•Y: # � AS SHOWN WAS I JKM i OWI523 RENSED PER ConnENra fRf fW5 1) i UMITS OF NYSDEC FRESHWATER . -♦ 1 - + ` e 05/1823 REVISEDPER COMMENTS ICM IWS WETLANDIOOFOOTADACENT a .�- P 05/0523 REVISEDPERENn JRF JWS 6 1 _ „� � vim. 1 `+ �•" '� 6 09/132VVED 3 REPER—E—EJRF JWS AREA AND TOWN OF SOUTHOLD + - - a WETLANDJURISDICTIONAL AREA r,-. �b - O ♦♦♦ .'� s o1ro323 CLIENT COMMEN ,e^ JCM JWS • � E � -! 1 1 I l�yl �. � • ` 4 12/1922 CLEIM COMMENn WPK JWS f.S s m 3 06/0122 CUEnT GonMEMT3 WPK JWS 05/1022 CUEWC—I1— JCM JWS I 01ro$aI _TCOMMEMrs JCM fW5 - y REV DATE I DESCRIPTION /'WETLAND W3 EM •'f �• I EORK 5 LI W r f - TION 8f UW FpR INE DRE UN A NG UN of ucwsEn PROFcss N THIS DOCUMENT. N. SIT RMATION_ i SITE NO:AL INE 4k 61405 MAIN ROAD FRESHWATER WETLAND SOUTHOLD,NY 11971 BOUNDARIES DELINEATED BY VHB ENGINEERING,SURVEYING, SUFFOLK COUNTY LANDSCAPE Rill AND LIMITS OF NYSDEC FRESHWATER GEOLOGY,P.C..ON MARCH 29,2023. SITETYPE: WETLAND 100 FOOT ADJACENT AREA AND TOWN OF SOUTHOLD 150'-0"CONCEALMENT POLE WETLAND JURISDICTIONAL AREA COPYRIGHT'C nail,n311fUTH E:GGv`EERL'G P.C..LLC nl.: actin RESERVED s '"'p•(�r�GW�IM�CRG a m M�Ii•K m�irrx•10Yn.TME pMM1G MY NGi 9E DiTF➢.REu4D.0�05EG, OSReUrFD a RETID 1801 EM NO'Gr1ER POm^Y WTNOIT 111E DdR6s RRTIFN P.G.UL CI- a A3wuTM _ W� d01fI11I1G O SHFEL TITLE: z RECEIVED S PIAN � FTNAI MAP � r 41EET NUMBETC 1 200'RADIUS PLAN AU GRnPDC9GtE T Z- 5 Lzonin e �,oard of Aoped�s J DECISION# 7939 _ — DATED : I cl 11 21 a 0 /1 61 MEN n ■■ ® ■■� ■■ ■ MESON M 0 MEMOMMEM ME ME 4 ■ ■■ ■■■ MEMOMMEN ME M■■M�■■M�- � ■ I" ■■■EEE® MEMEMEME■ � FRESHWATER WETLAND ■■■■■ .. .' r�i i>>] ■ M EE■■■E■■ ■■■E■■■M■■ ■® M LITE, ERS LP BOUNDARIES DELINEATED BY VHB ENGINEERING,SURVEYING, ' LANDSCAPE ARCHITECTURE AND i MENNEN ■ GEOLOGY,P.C.,ON MARCH 29,2023. ■■ , F1RF PROPOSED 150' �,�.rrl� ■■■■■■■■■■■■■ CONCEALMENT POLE ' .t �s."� .R.,,� SOUTHOLD ■ Owls ONE=■M ■ ■ ■ MENNEN rveftmv FRESHWATER WETLAND ' _ BOUNDARIES DELINEATED BY VHB ENGINEERING,SURVEYING, r D 0 -111T—RSEl MENNEN LANDSCAPE ARCHITECTURE AND EMEEppm, GEOLOGY,P.C.,ON MARCH 29,2023. ' , bWd ���''7��*����{ X,,c,l- _ Call STAT r".E E it 3 45' T% N IROA O ... •ter t .. • r. iAi STATE'TEGVIC gPECi RIWE Nl1YBE1i5 TO NEAREST IN?ERSEC AS SHOWN '•WAS �f KM r ` I '� P •M�+, 9 OFJISR3 REwsm PEa coMMENTS JRF JWS ■■ -�..,.LI�.Li 1 ��.. �I} � �. •�' !'1 1,l • , 4 w. JC. 8 05/1823 RI—EDPERCCMfnENTS JCM JWS -,A-mla S-� Ir■■ a„� �`a,y� ci f)` 7 05/0583 10 nR—MENTS JRF JWS� � 1�. 1 ~� � �_ � 9p < ♦.``. ��t 4`.. '.{,'4;* 5 04/13t23nensm PEn connENrs JRF Jws COMMENTS JCM JWS �'■ T 4 17/1422 CLDNTCOMMENTS WPK S■Mir ,� ��.�' �' �. oTy t.Y . :. 3 ONOIR2 Ci�ENT COMMENrs WPK JWS Sltf/ • 05/1022 CLENTConMENTS JCM Jws Y��`..•' - i I M/0581 CLIENT connENTs JCM JWS T 1 ■ ��■■■ .-e yr 4 5- Ift - y - rC r. REV DATE DESCRIPTION Dr✓,vm NEca ._. 4 . - r,4- ,-A jr Ab 'y.•F#'Aw.1/w. f”- �, (� � O LIMITS OF CLEARING.GRADING ' F•J;�e 7 o ■ yet A� Z Z AND GROUND DISTURBANCE �- LIMITS OF NYSDEC FRESHWATER ■ Z �Z _ WETLAND 100 FOOT ADJACENT ,,,.. .� AREA AND TOWN OF SOUTHOLD ➢ RK E •"r WETLAND JURISDICTIONAL AREA Z �l LEGEND El -LICENSE - 3 R-80-PARKS& IT 1 urv' P �{ .1 UNLE E 'I ACTING UNDER THE m CTKy C FRESHWATER WETLAND RECREATION M•[1 MARINE II OF THE ellsIS Doau�+so=CUM yaN,u ra- v m BOUNDARIES DELINEATED BY VHB ENGI yc ENGINEERING,SURVEYING, LANDSCAPE ARCHITECTURE AND SITE IN TION: GEOLOGY,P.C.,ON MARCH 29,2023. SITE NO:ALBERTSON MARINE �E o 1405 MAIN ROAD MEMO _-- SOUTHOLD,NY 11971 LIMITS OF NYSDEC FRESHWATER SUFFOLK COUNTY WETLAND 100 FOOT ADJACENT Rio RESIDENTIAL AREA AND TOWN OF SOUTHOLD SITE TYPE: NONE - WETLAND JURISDICTIONAL AREA 150`•0"CONCEALMENT POLE DDPYRIGHTO h2l.AZA8IP31 ENG6:EERL'GPC LLC ALL �,�.i RIGHTS RESERVED 03 t 3 T6 TIONIID EQS 113E OILY lY M PNRY i➢II�ME 6 � � �� ��• .�, � , � ';�-. � Jaz:, e�� �,M= ■ ■ +� r ♦ ' g3n3euT � , a 1ESm isoR Ra"NY oElra Pura,z >V _ • NOTE: E ■L�■ y � L iI "I, AERIAL IMAGE BASED ON GOGGLE MAPS DATA 2019& s"EET nom' SUFFOLK COUNTY,NEW INI1Y PLAN OIL t WETLANDS GIS I TIO 12018 o �7 SHEET NUMBER 1 VICINITY PLAN _ Z-06 a AUG 0 9 2023— DECISION# � N31 DATED: Zoning Board of Appeals o e n o _- \ AZIMUTH ENGINEERING P.C. y • ------ ------� v—— --— ------ --, LIT 1 District - Section Block _Lot. Owner. O.wner's Address. UL1,,," E E TOWERj 1000 56 1 4.2 Scott&Pauline Carter 1605 Mill Path,Southold,NY 11971 -_-- - -� ' 1000 56 1 10.1 Town of Southold 2205 Mill Path,Southold,NY 11971 1000 56 1 11.2 Angela Norton 610 Pond Avenue,Southold,NY 1971 --- -_ 1000 56 1 11.6 Angela Norton 610 Pond Avenue,Southold,NY 1971 1000 56 1 11.11 Angela Norton 610 Pond Avenue,Southold,NY 1971 100056 1 11.12 Angela Norton 610 Pond Avenue,Southold,NY 1971 veaml-I 1000 56 3 13.3 Angela Norton 61025 Route 25,Southold,NY 11971 1000 56 3 14 New York Telephone Co. 60975 Route 25,Southold,NY 11971 s PRO ECT YOURSE E e 1000 56 3 15 Budds Pond Marine Inc. 61405 Route 25,Southold,NY 11971 elOw. Call bem,.y"as PDR STATE SPMFIC dRECT PHONE NUMBERS 1000 56 3 1 Main Road Brokerage LI,LLC 61505 Route 25, Southold,NY 11971 —T.�Nw e„coM �,� RAw RT OHEDIoiD Rn � JKM 1000 56 3 2 Emmanuel&Toula Leodis 61575 Route 25,Southold,NY 11971 AS SHOWN WAS 9 06/15/23 REVISED PER COMMENTS' JRF JWS 1000 56 3 3 Emmanuel&Toula Leodis 61625 Route 25,Southold,NY 11971 a 05/1&23 REVISED PERCOMMEN JcM Jws ; 7 05/05/23 REVISED PER COMMENTS JRF JWS 1000 56 3 4 Town of Southold 61725 Route 25,Southold,NY 11971 6 04/1323 REVISEDPERCOMMEWS IRF JWS 5 01/0323 CUE-COMMENTS JCM JWS 1000 56 3 5 62375 Main Road LLC 61825 Route 25,Southold,NY 11971 4 17/1422 CLDN COMMENTS WPK JWS 3 0610122 GHENT COMMENTS WPK JWS 1 ' 2 0$/1022 CLIEM COMMENTS JCM JWS 1000 56 3 6 62375 Main Road LLC 62375 Route 25,Southold,NY 11971 1 04/0521 CUDNTCOMMRNTS ICM IWS REV DATE DES 1000 56 5 7 Margaret Dato 445 Budds Pond Road,Southold,NY 11971 HECN 1000 56 5 8 Ecka Grando 545 Budds Pond Road,Southold,NY 11971 r 1000 56 5 9 Suffolk County 64 Budds Pond Road,Southold,NY 11971 Oil 1000 56 5 10 Marcia Jurinovic 745 Budds Pond Road,Southold,NY 11971 r- 1000 56 5 11 Jonathan Tibett 845 Budds Pond Road,Southold,NY 11971 .. " 1000 56 5 16 Patrick Redmond 750 Budds Pond Road,Southold,NY 11971 R U c NAL 374- IT IS A T10 LAW'TdN 1000 56 5 17 Jean&John Weber 590 Budds Pond Road,Southold,NY 11971 UNLESS TH ACnNc urvDeRli"HE e n OF THE RESPD CENSER PROFESSlO ENdNEER,TO IS DOCUME r 1000 56 6 1.1 Eli Green&Dalton Route 25,Southold,NY 11971 SITE INFORMATION: 1000 56 6 1.2 Suffolk County 61330 Route 25,Southold,NY 11971 SITE NO:ALBERTSON MARINE 1000 56 6 2.2 Budds Pond Marina Inc. 61500 Route 25,Southold,NY 11971 61405 MAIN ROAD SOUTHOLD,NY 11971 1000 56 6 3.4 61600 Main Road LLC 61600 Route 25,Southold,NY 11971 SUFFOLK COUNTY RECEIVED SITE TYPE: 150'-0"CONCEALMENT POLE AUG 0 9 2023 7�� 6eAOWNOA�' ,AAT FNCTEERAGPGLLCAL v RIGHTS RESERVED 0 ALL ME oiND1ATON CWTAWEO HDRflN 6 ar AVMOfd1ID fiR Ug QAY EY THE PARtt Pi.W tl1011 TIE Zoning Board of Appeals .a«VAS NN PAO E9wroeHON IT R f9i1=nos eUNNG NAY HOT BE COPIED.REUSED,us¢oaT. ONSR11[1UTD OR REI&D R1t ANY DTRR PN805E T1QIT TIE —TTEN NRITTII maAft DE ATDNTI dOXEFRPoC P.C,lit S J Q SHEET TITLE:- 200'& ITLE:200'6T.500'PROPERTY OWNERS LIST z P ir, SH NUMBER Z-07 1 PROPERTY OWNERS LIST LMAP . EVIEWED BY ZBA . 0ECISION# ' DAT' Et: : I ai - NO 6i I. NOT ALL EXISTING INFORMATION SHOWN FOR CLARITY. - 2. COMPOUND PLAN BASED ON SITE SURVEY BY AMERICAN ENGINEERING&LAND SURVEYING P.C.SIGNED o BY STEPHEN E.RAVN P.E.L.S.LICENSE NO.49664&DATED 10/24/18) - = 3. FINAL LOCATION OF EQUIPMENT TO BE CONFIRMED WITH OWNER&ELITE PRIOR TO CONSTRUCTION. Z 4. LOCATION AND INSTALLATION OF EQUIPMENT TO BE IN ACCORDANCE WITH THE STRUCTURAL g ANALYSIS. TOWER DESIGN TO BE BY OTHERS. w PROPOSED MESA CABINET(BY ® - S. CONTRACTOR SHALL CONFIRM ALL EXISTING CONDITIONS PRIOR TO THE START OF WORK. PROPOSED 8'_0"x 10'-O"PREFABRICATED ELITE)TO BE INSTALLED ON 6. FINAL DESIGN OF PIERS TO BE CONFIRMED ONCE ELITE HAS PERFORMED A GEOTECHNICAL BORING AND O EQUIPMENT PLATFORM WITH HANDRAIL PROPOSED TREE(TYP OF 34t) H-FRAME AND ELEVATED ABOVE® AZIMUTH z S' 0 KIT ELEVATED T ABOVE GRADE ON (EMERALD GREEN ARBORVITAE 6'-0"TALL MIN.) FLOOD ELEVATION ® ENRINEERlNO P.C. PROVIDED A REPORT. CONCRETE PIERS PLANTED IN STAGER PATTERN TO CREATE . (SEE DETAILS I&2,SHEET Z-17) MAXIMUM CONCEALMENT(BY ELITE) ' (SEE DETAIL 9,SHEET Z-12) PROPOSED UTILITY H-FRAME® � �J (TYP.OF 2)(SEE DETAIL 5,SHQ_T Z-17) ELITE�TOWLRS".LP — PROPOSED H-FRAME MOED _ LIMITS OF CLEARING,GRADING _ _— TRANSFORMER(BY EUT AND GROUND DISTURBANCE — ` ® 7- 00 00 0 0 0 0 0 0 0 0 0 0 7 S'.QIIZHOID` o -- O O O O O O O O O O O O I PROPOSED POWER CONDUIT ROUTED FROM TRANSFORMER TO METER BANK O (SEE DETAIL I,SHEET Z-12) PROPOSED FIRE DISTRICT CABLE BRIDGE y O 10'-0"A.G.LZ-14 DETAIL 4,SHEET SEE I 0 PROPOSED VERIZON WIRELESS ( ) O r - n O UTILITY METER MOUNTED IN ^' m OPEN SOCKET(BY ELITE) 0 O µ f\ O ® C PROTECT YOURSE� 0 FUTURE CARRIERI FUTURE CARRIER I Z I O O EQUIPMENTAREA EQUIPMENTAREA O fl—� F I Call e�malm a¢ I I FOR SPATE SPEOHC DIRECT PHWE NUYEEHS PROPOSED MULTI METER-METER PACK MSIT wxW.cAuan.cou WITH DISCONNECT(BY ELITE) scuE: �,: � O TO BE INSTALLED ON H-FRAME AND L — ——— — w ELEVATED ABOVE FLOOD ELEVATION AS SHOWN GR WAS JKM F w / I ® 9 06/15/23 REVISED PEA C°MMENTS JRF JWS'll O PROPOSED FIRE DISTRICT CABLES ROUTED ON I � � JcM Jws23 EVISED PERCOMMENiS PROPOSED 12'-0"WIDE ACCESS e 05!18R PROPOSED VERIZON WIRELESS 7/8"0 COAX CABLES — I PROPOSED CABLE BRIDGE FROM FIRE DISTRICT GATE(TYP OF 2 x 6'-0")(BY ELITE) 7 0510$23 REVISED PER COMMENTS JRF JWS I b ROUTED ON PROPOSED CABLE BRIDGE TO TOWER �' `� EQUIPMENT TO PROPOSED TOWER P OF I � � I (TY ) / ''' (SEE DETAIL I,SHEET Z-13) 6 0411323 0.EVISEDPER COMMENTS JRF JWS O (TYP OF 4 PER SECTOR,12 TOTAL) ( — I ® 5 01/0323 CUENTCOMMENTS JCM JWS I V� PROPOSED VERIZON ANTENNAS&EQUIPMENT a 17/1422 a--Mll n WPK JWS m \ �— (BY VERIZON WIRELESS)WITHIN PROPOSED 0 � 1122�ENTCOMMS WPK JWS �— �— —— _— I CONCEALMENT POLE SEE SHEET I 2 osoio22O.lENTcoMMwrE ��ECKEC JWS ----- ---- ( ) 185'TO WETLAND W2 I 0 0 ) I— ——— J \ ® I 04!0521 CUENTCOMMDNTS ® REV DATE DESCRIPTION O11IN 11111 IN A J i PROPOSED ISY MULTI-SECTION I w Z 11 MULTI-SIDED RADOME I Izp" CONCEALMENT TOWER(BY ELITE) t N0 1 IROPOSED 70'-0"x 35'-0" IK,450 SQ.FT.)EQUIPMENT I w ® C I I COMPOUND(BY ELITE) I FUTURE CARRIER ®I �C!" O I EQUIPMENTAREA p �` ® y R L -- - - - - --J wS 0 ) ON NAL (NEER-LIC ER 537 — -- IS ON OF LAW R P 70LO" U LATE ACTING UNDER THE E R PROPOSED -0"HIGH BLACK 0'— I D (zN518LE L10EN8W PROFES9Q \ 61N 6' RTD TER 7HI5 DOWL,W CHAIN LINK FENCE(BY ELITE)(SEE DETAIL 1,SHEET Z 13) SITE I MXC"fION: PROPOSED VERIZON WIRELESS UNDERGROUND POWER&TELCO \ SITE NO:ALBERTSON MARINE PROPOSED VERIZON WIRELESS 10'-0"x 20'-0"STEEL PLATFORM CONDUIT(BY VERIZON WIRELESS)ROUTED FROM METER RACK& \l (BY VERIZON WIRELESS) WITH 42"TALL HANDRAIL&8'-6"TALL MESA CABINET TO PROPOSED PPC&TELCO CABINET ON 61405 MAIN ROAD w STEEL CANOPY(200SQ.FT.)INA 10'-0"x 20'-0"LEASE AREA(200 SQ.FT.) PROPOSED EQUIPMENT PLATFORM(SEE DETAIL I&2,SHEET Z-12) � I SOUTHOLD,IvTY 11971 (SEE SHEET Z-09) SUFFOLK COUNTY LIMITS OF CLEARING,GRADING AND GROUND DISTURBANCE EXISTING BUILDING w LIMITS N 100 FO FRESHWATER SITE TYPE: AREA AND I OO FOOT ADJACENT T 150'-0"CONCEALMENT POLE AREA AND TOWN OF SOUTHOLD WETLAND JURISDICTIONAL AREA COPYRIGHT 4f ll:ll,AZPIITEki FNGCREEAING P.C.,IIC ALL RIGHTS RESERVED TN6 ORAIpG NiO ALL TIE NFUT1l,W LWTAdEO NWN 6 '9 PROPOSED VERIZON WIRELESS UNDERGROUNDS mA�cTm°�cYR io uaP/T is�Tu�vO1a ms °i POWER&TELCO CONDUIT ROUTED FROM UTILITY s®IiTn as NOT uPG�N FinaR,�—INrT a gDoTex° W NOTE: W TH.T THE DwwFss r.— AmuTx SILT FENCE,STRAW BALES,AND OTHER EROSION AND SILT POLE TO TRANSFORMER&MESA CABINET ENaNDTaT P.G.ur N RECEIVED CONTROLS WILL BE INSTALLED AND MAINTAINED DURING z PROJECT WORK,AS NECESSARY,TO PREVENT ADVERSE {�EL7¶ a IMPACTS ON WETLANDS. COMPOUND PIAN _ 0 AUG 0 9 2023 I COMPOUND PLAN 4 sx NUMBER oo caaexlc SCAIE E:1/4"=1'4'FOR 22'k34'DRAWINGS ! Z-UO NN tt;Fn - - SCALE:1/8"=1'-0'FOR 11'5:17'DRAWINGS Zoning Board of Appeals D BY �B/� DECISION# � !-! SATED: n T— ri '✓ � I I \\I I IIAZIMUTH C. s, FUTURE CARRIER I EQUIPMENTAREA I PROPOSED 150'MULTI-SECTION _ I MULTI-SIDED RADOME CONCEALMENT TOWER(BY ELITE) L — —————— —— — —— —— — — —— —— —— — ——— — ——— —— —— — —— — — ELITE TOWTRS LL MUMOM PROPOSED VERIZON WIRELESS 24"0 CONCRETE PIER(TYP OF 6)(SEE DETAIL 4,SHEET Z-14) PROPOSED VERIZON WIRELESS GPS UNIT MOUNTED 2'-0"ABOVE PROPOSED CANOPY (TYP OF 4)(SEE DETAILS,SHEET Z-I5) v�erizonv PROPOSED VERIZON WIRELESS I I J STEEL CANOPY(ABOVE) PROPOSED VERIZON WIRELESS DUAL BAND RRH UNIT(TYP I I OF 3 PER SECTOR,9 TOTAL)(SEE DETAIL 2,SHEET Z-I4), DIPLEXER(TYP OF I PER SECTOR,3 TOTAL)(SEE DETAIL 6 PROPOSED PROPOSED VERIZON WIRELESS WORK LIGHT SHEET Z-15)&TRIPLEXER(TYP.OF I PER SECTOR,3 TOTAL) (TYP OF 2)(SEE DETAIL 8,SHEET Z-12) FOR MOUNTING(SEE DETAIL 2,SHEET Z-15) I elDw. Dom. �• 1\ I Call SMATE SPE 1 FOR STATE mT.- DIRECT PHONE NUMBERS _ N9P WNN.CAU911.0011 r PROPOSED VERIZON r PROPOSED VERIZON WIRELESS I I WIRELESS BATTERY CABINET I EQUIPMENT CABINET I .000, AS SHOWN RRA WAS JKM I _ I (SEE DETAIL I,SHEETZ-IS) I _ IIL — — — — — — 9 ONISM RE .PERCOMMENTS IRF jws (SEE DETAIL I,SHEET Z-IS) � 1 8 I 05/18M REASEDPERCOMMENR JCM IWS 7 05105113 REVLSED PER COMMENTS IRF IWS 1 PROPOSED VERIZON WIRELESS CABLE 6 04/13/23 REVISED PER COMMENTS TRF Iws RRH RRH RRH RRH `' BRIDGE(SEE DETAIL 4,SHEET Z-14) 5 01/0323—COMMENTS IcN Iws PROPOSED VERIZON WIRELESS r AX 4 17/1482 CLEINT COMMENTS wPK ws DISCONNECT SWITCH MOUNTED PROPOSED VERIZON WIRELESS 7/8"0 COCABLES I TO PROPOSED H-FRAME I 3 06/0122-COMMENTS wPK Iws ROUTED ON PROPOSED CABLE BRIDGE TO TOWER 1075//01;01227 CUENTCOMMEN S IcN I-I I I (TYP OF 4 PER SECTOR,I2 TOTAL) j I cuwrconnENTs fcM Iws L—— —— REV DATE DESCRIPTION °erg Hev o y"CZE k,,11 RECEIVED \�� o � AUG 0 9 2023 E EO �-7 N �l U - FEs095 L/� Zoning Bo/ ENGINEER-L 095 4^�4 and of q TON OF LAW FOR Y 30N, PPeals NNyy ARE ACTING UNDER Tk4R`EC310N r OF -RESPONSB E L CENSER PROFESSIONAL E ,NEER.TO ALTER Td�l IHIS DOCUMENT. I I I S E-1NE8&MATION: SITE NO:ALBERTSON MARINE I I I PROPOSED VERIZON WIRELESS UNDERGROUND 1 I POWER&TELCO CONDUIT ROUTED FROM UTILITY 61405 MAIN ROAD / POLE TO TRANSFORMER&MESA CABINET (SEE DETAIL I&2,SHEET Z-12) SOUTHOLD,NY 11971 I I O I I I rn I O I SUFFOLK COUNTY 20'-O"± 1 I SITE TYPE: L L - - - -- --J L- - - - - - - J 150'-0"CONCEALMENT POLE PROPOSED VERIZON WIRELESS 42"TALL HANDRAIL PROPOSED VERIZON WIRELESS WORK LIGHT F T T T ZZE T T T T mPrwcrrromz3,AGHIER E"'E EAn4c ,sap1 wmpaan FlA ug ora<v ar THE PARrc FDR rNaN M (TMP OF 2)(SEE DETAIL 8,SHEET Z-12) E E E E E E E E E vIc AHD.0 ME wEavAnw cwrANm xpmN s pi I pU1rP10 WY NOT ff gAE0.REUSED,p$03D. rpd(rAs m�mnclm a ro w W rt R gARDA Ms W UIYTA®UIFD OR 1✓flm UPW FOR AAV OMA RII&O S IHpIT ME EmAEs■drip CONSENT OF AIDIUDI K O SHEET nnE: PROPOSED VERIZON WIRELESS POWER&TELCO I a--• m CABINETS MOUNTED ON PROPOSED HANDRAIL INA L IIIA P EQ LAN z 0 o _ 6TfEET NUMBC 09 1 �EQUIPMENT PLAN a — ®ECISIOiV# �3 DATED; �02 � I c � I ...OPOSED VERIZON WIRELESS ANTENNA PROPOSED VERIZON WIRELESS ANTENNA = MOUNTED WITHIN CONCEALMENT POLE MOUNTED WITHIN CONCEALMENT POLE "y (TYP OF 2 PER SECTOR,6 TOTAL) (TYP OF 2 PER SECTOR,6 TOTAL) (SEE ANTENNA SCHEDULE ON THIS SHEET) (SEE ANTENNA SCHEDULE ON THIS SHEET) 093 PROPOSED CONCEALMENT POLE ANTENNA 093 PROPOSED CONCEALMENT POLE ANTENNA ppp y MOUNT(COMMSCOPE PART NO.MTC37319) -y y� MOUNT(COMMSCOPE PART NO.MTC37319) ` `rc<` (TYP OF 2 PER SECTOR,4 TOTAL) �i 1E` (TYP OF 2 PER SECTOR,4 TOTAL) PROPOSED TRILEXER(TYP OF I PER SECTOR, 3(� '�0 ENOINEERINO RC. G�.A (SEE DETAILS,SHEET Z-15) G AO (SEE DETAILS,SHEET Z-15) 3 TOTAL)(SEE DETAIL 6,SHEET Z-15) > S' S'9 PROPOSED 40"DIA. PROPOSED 40"DIA P PROPOSED 40"DIA. MULTI-SECTION-MULTI-SIDED MULTI-SECTION-MULTI-SIDED S�G��1, MULTI-SECTION-MULTI-SIDED EG�pN RADOME CONCEALMENT POLE ELITE RADOME CONCEALMENT POLE P v RADOME CONCEALMENT POLE PS J� P P�Q\A \\�` •1 'WERS L I PROPOSED 6"0 I PROPOSED 6"0 C2 ,i n ` MAIN PIPE MAST MAIN PIPE MAST ® � A I � A2 ® ® a s a BI B2 ven2mm/ J PROPOSED VERIZON WIRELESS ANTENNA PROPOSED VERIZON WIRELESS ANTENNA em���DB Ta e �,Y.,aA RSA 4 NN MOUNTED WITHIN CONCEALMENT POLE MOUNTED WITHIN CONCEALMENT POLE PROPOSED 6"0 MAIN PIPE MAST (TYP OF 2 PER SECTOR,6 TOTAL) (TYP OF 2 PER SECTOR,6 TOTAL) (SEE ANTENNA SCHEDULE ON THIS SHEET) (SEE ANTENNA SCHEDULE ON THIS SHEET) i Calll nim,.yo"ad FOR STATE SPECIFIC DIRECT PHONE NUMBERS PROPOSED VERIZON WIRELESS ANTENNA PROPOSED VERIZON WIRELESS ANTENNA msT.WMW.CAULIIMOM i /R&', MOUNTED WITHIN CONCEALMENT POLE MOUNTED WITHIN CONCEALMENT POLE S`"E,� ,\ qS SHOWN PwR WAS JKM 11(TMP OF 2 PER SECTOR,6 TOTAL) G (TMP OF 2 PER SECTOR,6 TOTAL) (SEE ANTENNA SCHEDULE ON THIS SHEET) yF'��` (SEE ANTENNA SCHEDULE ON THIS SHEET) 9 06/1523R ISEDPERCOMMRN JRF JWS � oECEIVEp 8 05/1823 RENSEDPERCOMMENTS JCM JWS ryry 7 05/0523 REVISED PR COMMENTS JPF JWS ' AUGO 6 04/1323 REVISED PER COMMENTS JRF JW$ U 9 LOL{ I 5 01/03/23 CUENTCOMMENTS JCM JWS �n J I 4 12/1422 CtFWiCOMMENTs WPK JWS ((9(� 3 06/0122 CUENTCOMMENTS WPK JWS [Zoning Board of 2 05/10/22-TCOMMENTS JCM JWS I 04/05/21 CLIENTCOMMEMTS I JCM I JWS 1 VERIZON CLUSTER 1 ANTENNA PLAN @ 1464"A.G.L. D w"="£ N.T.S. 2 VERIZON CLUSTER 2 ANTENNA PLAN @ 141'-2"A.G.L. °"�"QBE`^£ N.T.S. 3 VERIZON DIPLEXER PLAN BELOW D"A""'s°"E N.T.S. REV DATE DESCRIPTION �O s I ANTENNA SCHEDULE IN YO NAL G EEP() UMBER:09537 PROPOSED ANTENNA AND RRU CONFIGURATION 5 TON OF LAW F Y ANTENNA UN RE ACTING UNDER THE ON OF 0 SIB4 LICENSED PR NAL f EN R` THIS DOCU ' / J PROPOSED ANTENNA ANTENNA HEIGHT WIDTH DEPTH WEIGHT FACE AREA ANTENNA ANT. CL. RRU SITE INFORMATION: SECTOR QUANTITY CONFIGURATION STATUS (IN) (IN) (IN) (lbs) (S.F.) AZIMUTH ELEV. (FT) CONFIGURATION STATUS SITE NO:ALBERTSON MARINE a Al 1 MX06FIT465-02 NEW 52.5 12.2 10.7 94 4.45 146.1 60' RRH[32/1366a NEW 61405 MAIN ROAD RRH 135/613 SOUTHOLD,NY 11971 a A2 1 MX06FIT265-01 NEW 32 11.61 4.53 26.5 2.58 141.2 60' RT-8808-77A NEW SUFFOLK COUNTY B1 1 MX06FIT465-02 NEW 52.5 12.2 10.7 94 4.45 146.1 220' RRH B2/B66a NEW SITE TYPE: RRH B5/B13 150'-0"CONCEALMENT POLE m B2 1 MX06FIT265-01 NEW 32 11.61 4.53 26.5 2.58 141.2 220' NEW RT-8808-77A ro_HTm.v,__END>NEERM,DP.�.,�D,�, A" _a C1 1 MX06FIT465-02 NEW 52.5 12.2 10.7 94 4.45 146.1 330' RRH B2/666a NEW ".M ���°I>g�YBYTNEPA19T=-E6 m«Mss DRTiRAD1EM ORTD waM ITIS DERTPIFD.THIS " RRH 135/613 �=NOTM� D�Eo,��a=D= p A m OR RDkD LIDDN Pqt ANY_T PIR_ qlT TIE EanE55 YLTIFN CONSENT 6 AZdU1X N C2 1 MX06FIT265-01 NEW 32 11.61 4.53 26.5 2.58 141.2 330' RT-8808-77A N EW ENCNEERND M 91EET nTLE: m JAL MAP -ENNAPLANS7L m � AN A SCHEDULE z o m �� ® I SHEET NUMBER: Z-10 a DECISION# 3 DATED: �L ;?, 4'-0' � TOP OF PROPOSED FIRE PROPOSED FIRE DISTRICT DISTRICT WHIP ANTENNASJII ANTENNA MOUNTED AT TOP OF EL=164'-10"t A.G.L n CONCEALMENT POLE(TYP OF I) - o (SEE SHEET Z-I6) PROPOSED 5'-0" y TALL PIPE MOUNT(TYP OF 2) ® B PROPOSED FIRE DISTRICT ®® 11 EQUIPMENT(SEE SHEET Z-16) EDD P. TOP OF PROPOSED NINEERINC. TOP DIAMETER Of RADOME CONCEALMENT POLE MULTI-SECTION MULTISIDEDEL=I 0-0"±q.G. 1 CONCEALMENT POLE=40" Ey".ta PROPOSED VERIZON WIRELESS ANTENNA PROPOSED ANTENNA ELITE` 'Z� S LP t�Yffi"Nthe WITHIN MOUNTED WITHIN CONCEALMENT POLE CENTERLINE=146'-1"t A.G.L (TYP OF 2 PER SECTOR,6 TOTAL)-,, (SEE DETAIL I,SHEET Z-14) PROPOSED TRIPLEXER(I PER SECTOR,3 TOTAL) PROPOSED ANTENNA (SEE DETAILS,SHEET Z-15) i CENTERLINE=141'-2"t A.G.L `>=S8ltTHOLD- BOTTOM OF ANTENNA SECTION EL=138'-0"±A.G.L I � I FUTURE ANTENNA verbonl( CENTERLINE:;132'-0"t AG.L I I I i BOTTOM OF ANTENNA SECTION EL=126'-0"t A.G.L. �TEcr�rOuusE� w � I t;c QFDfi11 STATE SPEOFlC DIRECT PHONE NUNEUtS I c U ZFUTURE ANTENNA Hsr:N'10Y.C,ViBFF.CON 00 ±CENTERLINE=120'-0"TA-G.L. BT: n�03D BT. I II O W AS SHOWN ORAwI WAS I JKM li K y 9 06/15/23 REVISED PER COMMENTS IRF JWS BOTTOM OFANTENNASECTION I I 8 OS/1FY23 RE-MPERCOMMENTS JcM JwS EL=I14'-0"tA.G.L I 7 MOM REVISED PER COMMENTS JRF JWS 6 04/13/23 REVISED PER COMMENTS JRF JWS _L 01/03(13 CFFENTCOMMENTS JCM JWS 1i 4 12/14/22 CLEINTCOMMENTS WPK JWS _ FUTUREANTENNA I I I 1 CENTERLINE=108'-0"±A.G.L 3 06101t22 QENT connwTs WPK JwS 1 RECEIVED 2 0$/1022 CLE:Ni COMMFNR JCM JWS 1 I I 04/0521 C—TCOMMEWS JCM JWS III PROPOSED FIRE DISTRICT CABLES ROUTED REV DATE DESCRIPTION BOTTOM OF ANTENNA SECTION WITHIN CONCEALMENT POLE TO FIRE AUG 0 9 2023 EL= 02'-0"t A.G.L DISTRICT ANTENNAS(TYP OF 1) es Zoning Board MAP S K FUTUREANTENNAeS peals s} �� I I CENTERLINE=96'-0"t A.G.L p I I I PROPOSED VERIZON WIRELESS 7/8"0 COAX CABLES ROUTED ON y I I PROPOSED CABLE BRIDGE TO TOWER(TYP OF 4 PER SECTOR,12 TOTAL) _ J hBOTTOM OF ANTENNA SECTION I PROPOSED VERIZON WIRELESS DUAL BAND RRH UNIT UYP OF 3 PER SECTOR,9 E ON 1 TOTAL)(SEE DETAIL 2,SHEET Z-14), YORK 0 oNa, / DIPLEXER(TYP OF I PER SECTOR,3 TOTAL)(SEE DETAIL 6,SHEET Z-15)&TRIPLEXER EER NUMRER:0ON-1 I� (TYP.OF I PER SECTOR,3 TOTAL)FOR MOUNTING(SEE DETAIL 2,SHEET Z-15) I FUTUREANTENNA u S ARENAELIC UNDER T�OF LAW F EQ N, I OF 0 SLE E LCETHIS PR BASE DIAMETER OF RADOME I I I CENTERLINE=84'-0"t A.G.L. Rv4N-T�a NSE DOCUM MULTI-SECTION MULTI-SIDED I _ CONCEALMENT POLE=40" 1 PROPOSED 12'-0"WIDE ACCESS GATE(TYP OF 2 x 6'-0")(BY ELITE)(SEE DETAIL I,SHEET Z-13) SITE INFORMATION: SITE NO:ALBERTSON MARINE TOP OF BASE POLE BOTTOM OF ANTENNA SECTION PROPOSED MESA CABINET(BY ELITE) EL= B'-0"±q.G.L EL=78'-0"±A.G.L 61405 MAIN ROAD PROPOSED FIRE DISTRICT EQUIPMENT CABINET ON N-0"x 6'-0" PROPOSED VERIZON WIRELESS CABLE ELEVATED EQUIPMENT PLATFORM(SEE SHEET Z-16) SOUTHOLD,NY 11971 BRIDGE(SEE DETAIL 4,SHEET Z-14) PROPOSED VERIZON WIRELESS UTILITY METER MOUNTED IN OPEN SOCKET(BY ELITE) SUFFOLK COUNTY PROPOSED VERIZON WIRELESS STEEL CANOPY(ABOVE) PROPOSED MULTI METER-METER PACK WITH DISCONNECT(BY ELITE) SITE TYPE: TOP OF VERIZON WIRELESS GPS UNIT I 150'A"CONCEALMENT POLE PROPOSED 8'-0"X 10'-0"PREFABRICATED EQUIPMENT PLATFORM WITH HANDRAIL EL= 3'-6"t A.G.L PROPOSED VERIZON WIRELESS GPS KIT ELEVATED T ABOVE GRADE ON CONCRETE PIERS TOP OF VER ZON WIRELESS STEEL CANOPY ANTENNA MOUNTED ON PROPOSED (SEE DETAILS 1&2,SHEET Z-17) EL=I I'-b"t A0_ CANOPY(SEE DETAIL 3,SHEET Z-15) _. — TOP OF FIRE DISTRICT EQUIPMENT CABINET WPTRIGFT[6 L2l,gZnIV1H ENGEREERIIRG P.C,LLCAJ1 _ RIGHIS RESERVED AND ALL 11E PIFOIWARRI CORTANEO HEWIx 4 v EL=10'-0"t A.G.L Acn"v�m�imA'�cFED mT m wa IT S�TW9,TT"ws PROPOSED VERIZON WIRELESS EQUIPMENT CABINET& ons Gas Not woo+FmoRm usmosm w BATTERY CABINET(BEYOND)(SEE DETAIL I,SHEET Z-IS) TOP OF VERIZON WIRELESS CABINET,:;L rTxaT THE Dwr�MaiRR carmxr aF AauurH EL=9'-8"t A.G.1_11�/ EHDIRFIAVO P.G,uc ^�! PROPOSED 6'-0"HIGH BLACK CHAIN LINK FENCE O O TOP OF CHAIN LINK FENCES SHEET TITLE (BY ELITE)(SEE DETAIL I,SHEET-13) O O EL=6-0"t A.G.L. GRADE EL= 0'-0"AG --_----- ON z 5'-0"AMSL —� BOTTOM OF ALL EQUIPMENTS o 1 SOUTHEAST ELEVATION G .� 5 0 5 ;1116=F D 4 D os ���Ne� Z a _ F. . .D 4�r7 a FINISHED GRA[ CH SLOPE THICKNESS FINISHED GRADE-MATCH SLOPE THICKNESS I 2'-0"t EXISTING GRADE c AND MATERI/-....;=-XISTING CONDITIONS - AND MATERIAL OF EXISTING CONDITIONS- OR ONDITIONS OR AS DIRECTED BY THE ENGINEER OR AS DIRECTED BY THE ENGINEER - M-1- I-` _ - n WARNING TAPE 2-4" WARNING TAPE 2-4" ro WARNING TAPE @ € -- -_-`---__--- _- -_ __-----__---_- I TRENCH '` ENOIN EERING P.C. -III ___ --- I I__I ________ _I� -I I I_---- --— -I I I� -III ----- ---- - III o COMPACT FILL(90%)OR _ _____-_-__ I i - I AS PER UTILITY COMPANY m z I __I UNDISTURBED SOIL ;° z_ I—_ ___ ______ _I UNDISTURBED SOIL Q '-I REQUIREMENTS -III -----_ __ __III- -III _--_----_----___ I- - ELITATOWERSLP rm"W _________ _ CLEAN FILL(COMPACTED = _ _ CLEAN FILL(COMPACTED O -III --_—-_—------III IN 12"CONTROLLED LIFTS) -III_ IN 12"CONTROLLED LIFTS) I= 66" 6' 6" —I =I I T UNDISTURBED SOIL MIN MIN III - MIN MINTi I- . ' - =1 I- -1 f curxoL-11r, (=I CLEAN SANDCLEAN SAND17 III—III—I I-I I� I I I III— I I I—I III 4"0 SCH 40 TELCO CONDUIT III—� I 1 (I)2"PVC ELECTRIC CONDUIT CLEAN SAND SUITABLE (2)4"PVC ELECTRIC CONDUIT (WITH 2OOLS MINIMUM PULL WIRE) 1_0. FOR CONDUIT BEDDING NOTE (1)2"PVC TELCO CONDUIT MIN NOTE: (2)4"PVC TELCO CONDUIT 2"0 SCH 40 PVC ELECTRIC CONDUIT NOTE I. MINIMUM SEPARATION PER TELCO AND L MINIMUM SEPARATION PER TELCO AND UTILITY COMPANY REQUIREMENTS. UTILITY COMPANY REQUIREMENTS. 1. IF FREE OR ORGANIC OR OTHER DELETERIOUS MATERIAL,EXCAVATED MATERIAL MAY BE USED FOR BACKFILL 2. IF NOT,PROVIDE CLEAN,COMPATIBLE MATERIAL COMPACT IN 8"LIFTS.REMOVE ANY LARGE . PA01EC 1O1R cRwrxic scniE caaPxlc sc..� ROCKS PRIOR TO BACKFILLING.CONTRACTOR TO VERIFY LOCATION OF EXISTING U!G 1 DEMARC TO SHELTER TRENCHING DETAIL aNFaen N.T.S. 2 SOURCE TO DEMARC TRENCHING DETAIL GIN£E) N.T.S. UTILITIES PRIOR TO DIGGING. a1aw. 3. IF CURRENT AS-BUILT DRAWINGS ARE NOT AVAILABLE,CONTRACTOR SHALL HAND DIG U/G MATCH EXISTING TRENCHING. rax STATE SPEMC 01REcr PHWE NuueExs EXISTING MATERIAL&GRADE RIGID STEEL CONDUIT RIGID STEEL Nor.Y/ilrl.C,111BIt.0011 GRADE EXPANSION COUPLING CONDUIT PLUG cRwPxic sc>," ! AS SHOWN �n WAS JKM 3 JOINT SERVICE TRENCH DETAIL �,�„ N.T.S. 9 06/15123 REN PERCOMMENTS IRF IWS CLEAN BANK RUN GRAVEL "co GRADE 8 05/18123 REV MPERCOMMENTS JcN )ws '•o _____-____-- BACKFILL WITH NO STONES 7 05/05/73 REVISMFmcOMMEN IRP !wS GREATER THAN 6". COMPACT 3!4"GRAVEL STONE ---=-- TO 95%MODIFIED PROCTOR. �/� /' z 3/4"CRUSHED STONE 6 o4n323 REVLTED PER COMMENTS IRF Iws __ ASTM C33,SIZE NO.57 5 01!03/13 HENT COMMENTS fCM Jw5 --------- YELLOW WARNING TAPE --------- 'v MARKED"CAUTION-GAS MAIN" �6"WIDE UTILITY WARNING TAPE < 12/1422 CLFJNTCOMMENTS wPK Iws 3 06101/12 CLIENTCONMENTS WPK JWS Z 00000000000000 O00000000 2 05/1012241ENTCAM- jcm Iws TRACER WIRE(SEE NOTE#3) 'v o o 0 o o 00 o o 0 o 0000 o 0 o o 0 o0o I 04/0521 CUNTC-.n ICM Iws �IIMIMIRIMMINIMUM L5"I.D.PE PIPE REV DATE DESCRIPTION °e'"" xEc"E T-0- RIGID STEEL CONDUIT C:) NOTE: P �Y I. ALL EXCAVATION SHALL BE HAND EXCAVATION ONLY. PVC PIPE COMPACTED SUBGRADE �. 2. PE PIPE INSTALLATION SHALL BE IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS. RIGID STEEL TO PVC ADAPTER K NOTE: 3. A YELLOW INSULATED COPPER TRACER WIRE SHALL BE INSTALL ADJACENT TO WEED BARRIER"TYPER" UNDERGROUND NON-METALLIC PIPING.ACCESS SHALL BE PROVIDED TO THE TRACER WIRE I. IF COMBINATION METAL AND PVC CONDUIT RUIN IS INSTALLED E.C.SHALL BOND METAL LANDSCAPE FABRIC OR EQUAL OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT EACH END OF THE CONDUIT TO SERVICE PANEL ►� 'y` '1 NON-METALLIC PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18 AWG AND THE 2. IF PVC CONDUIT IS EXTENDED ABOVE GROUND ALL SWEEPS AND CONDUIT ABOVE GROUND II INSULATION TYPE SHALL BE SUITABLE FOR DIRECT BURIAL COMPLIANT IFGC SECTION 404.15.3. TO SCH.80 GRMHICSCwr" 4. SPLICE BETWEEN STEEL GAS PIPE&PE PIPE TO BE THREADED. 6 GRAVEL COMPOUND DETAIL GIN PEED N.T.S. - 4 GAS TRENCHING DETAIL °" "'PEE N.T.S. 5 TYPICAL UNDERGROUND CONDUIT STUB-UP N.T.S. NOTE: oRK SE *6F A AL J — - 198E 095374 I. PROVIDE 3"LAYER OF MULCH AS SPECIFIED EMERALD GREEN ARBORVITAE / OVER ENTIRE WATERING SAUCER AT ALL Ir!N141�rAlat]4_. m rex r P 6'-0"IN HEIGHT MIN. uNLEux.ER71�DRTREE PITS OR OVER ENTIRE TREE BED. MSIBLE UCENSM PROFEBBIa2. PREPARED BACKFILL MIXTURE I PART PEAT, TU ALTER Txls 0oau CONCRETE CAP I PART HUMUS,I PART PARENT SOIL I BACKFILL SHALL BE THOROUGHLY MIXED. p 2 STRANDS NO.12 GA.GALV. SITE INFORMATION: 6"0 SCHEDULE 40 CARBON WATER IN 12:LIFTS DURING PLANTING. p ANNEALED STEEL WIRE-TWISTED SITE NO:ALBERTSON MARINE STEEL PIPE WITH YELLOW II IN NEW RUBBER HOSE SLEEVE FILLED WITH CONCRETE u, "' II 2 STRANDS DOUBLE 61405 MAIN ROAD O PROPOSED TIMED LIGHT(RB PIN STL360H) HI I WRAPPED AND TWISTED SOUTHOLD,NY 11971 (TYP OF I PER ICE CANOPY POST,TOTAL OF 4) � � I I 0 z I ISUFFOLK COUNTY GRADE,PAVEMENT OR Q I CIRCLED WATERPROOF TREE WRAPPING FINISHED GRADE f F71 PAPER 4"WIDE,50%OVER LAP. TIED WITH Z 11 STOUT HEMPCORD AT TOP OF BALL AND SITE TYPE: CUT&REMOVE BINDING FROM E I I AT HEIGHT OF SECOND BRANCHES 150'A"CONCEALMENT POLE 3"0xI0'-0"LONG SCH.40 PIPE TRUNK AND AS MUCH FROM BALL ^ I I AS POSSIBLE. CUT AND REMOVE PITCH AWAY FROM TREE TRUNK UPPER 1/3 OF BURLAP FROM BALL FINISHED GRADE CDPYRIGHCO L+ll.e�IV[H ENGIN}pRpiO P.0 LLC nil acxTs aESERVEn CONCRETE FOOTING(4,000 PSI)—'-' -,�.', F > wi man P°x v'�irp1 ra P"Amr` Pna wauM°�ii"ars ns coxrxncrta a ro ww Ir rs rrn3saa iws GFCI > © DUPLEX OUTLET WITH NEMA = TOPSOIL MIX BACKFILL "°'°uAr x°r m+m.RE114D,ascasla °R + 1 N NOTE © 3R OUTLET COVER(TYP OF 2) w GIT rlE waG —T GIP nmmix v TREE BALL - ,sHEEr TITLTITLE'T a I'-0" I. MOUNT TIMED LIGHT&OUT PER VARIES TAMPED TOP SOIL E MIN MANUFACTURERS RECOMMENDATIONS MIX CUSHION 6' CONSTRUCTION DETAILS 1 i I'-0" I'-0" �^ SHEET NUMBER Z- 2 7 BOLLARD DETAIL °"� Es`n� N.T.S. 8 TIMED LIGHT&OUTLET DETAIL a"^""'aT°n`� N.T.S. 9 TREE PLANTING DETAILSFiLINe N.T.S. — — — D BY Z BA AUG 0 9 20233 DECISION# 4-1 1 � DATED: lA ,) Zoning Board of Appeals a m 3/8"0 TRUSS ROD WITH HEAVY-DUTY GALV.LOCKABLE, - - TURNBUCKLE AT GATE ONLY DOUBLE GATE LATCH VARIES L 12'-0"GATE OPENING 10'-0"MAX VERIFY WITH SITE PLAN - I 1/4"GATE FRAME TYPICAL CHAIN LINK FENCE NOTES AZIMUTH T 1. GATE POST,CORNER,TERMINAL OR PULL POST 2 112"0 SCHEDULE 40 FOR GATE ! EIV R ITV EERINO P.C. WIDTHS UP THROUGH 4 FEET PER ASTM-FI083. 1 1/4"TOP RAIL 2 112"CORNER POST 2. LINE POST:2"0 SCHEDULE 40 PIPE PER ASTM-FI083. l 2"x2"-9GA.FENCE FABRIC ELITE�TO�'.�RSLP $/8"0 3. GATE FRAME:11!2'0 SCHEDULE 40 PER ASTM-FI083. 1 • ,,, ,,,,,,,,u",�,"�,,, LATCH RODjj 2 I/2"GATE POST 3/16"x 3/4"STRETCHER BAR AT CORNER AND GATE POSTS 4. TOP RAIL&BRACE RAIL 1 1/2"0 SCHEDULE 40 PER ASTM-F1083 _- 2"INTERMEDIATE POST - T'^t• 5. FABRIC"12-GAUGE CORE WIRE SIZE 2-INCH MESH,CONFORMING TO ASTM-A392 NO GAP BETWEEN FINISH 112"CROWN FOR DRAINAGE I - GRADE AND FENCE FABRIC 1.0.. 6. TIE WIRE MINIMUM I I-GAUGE GALV"STEEL AT POSTS AND RAILS A SINGLE WRAP i 2:1 SLOPE MAX OF FABRIC TIE AND AT TENSION WIRE BY HOG WITH FABRIC 14-GAUGE, :AIDW OLff MIN 4-POINT BARBS SPACED ON APPROXIMATELY 5 INCH CENTERS(BLACK) — 7. TENSION WIRE:7-GAUGE GALV,STEELP- i STONE OVER GEOTEXTILE FABRIC 1'-0"0 TIRE AT END OF S. GATE LATCH:DROP DOWN LOCKABLE FORK LATCH AND LOCK KEYED ALIKE Z SWING GATE(TYP OF 2) F 3:1 SLOPE MAX FOR ALL SITES IN A GIVEN MTA. ^+ F w p 0 9. HEIGHT=6FT VERTICAL I 6"0 x 18"DEEP CONCRETE Q C NTGA.TENSION WIRE, O� zz 0 O CONTINUOUS FOOTING WITH I I/4"PIPE F O F 10. ALL FENCE COMPONENTS SHALL BE BLACK VINYL COATED INCLUDING CHAIN SLEEVE 6"LONG m o LINK FENCING. 10"0 CONCRETET• Z m PROTEcr rouRSELF 12"0 CONCRETE FOOTING IN SOIL BRAIDED COPPER GROUND STRAP,2 PL _FOOTING I SOIL FOR FOR GATE AND CORNER POSTS (SEE GROUNDING SPECIFICATIONS) ZINTERMEDIATE POSTS Q IJpo'.. Ca11.1 —. FOR SITE SPEORC DIRECT PHONE NUMBERS MSIT:W ..CMLBII.CCM a•r DIGIN BT. `6 J BY: I AS SHOWN WAS KM jj 9 06/1 SF73 RE MPER COMMENTS JRF JWS _L 0$/18!73 REVISED PERCOMMENiS JCM JWS 1 FENCE&ACCESS GATE DETAIL N.T.S. 7 05/0523 REV6EDPERCOMME— JRF JWS 6 04/13/23 REVISED PER COMMENTS JRF JWS NOTE I s 01/03(73 CUENTCOMMENTS JCM JWS UNISTRUT PIPE/CONDUIT CLAMP PI 119 CABINET TO BE INSTALLED ON H-FRAME j 4 17114122 C E W COMMEN WPK JWS OR P2558-35(GALV.)(TYPICAL)FOLLOW PER MANUFACTURER'S SPECIFICATIONS TO ' 3 06101122-ENTCOMMENTS WPK JWS kF NUFACTURERS RECOMMENDATIONS BE ELEVATED ABOVE FLOOD ELEVATION 2 OS/1022 C4EMCOMMEMS JCM Jws R BOLT TORQUE ! 1 1 I 04/05/21 CIIENTCOMMENTS CM WS REV DATE DESCRIP Y°"' "eT 3 1/2"O.D"POST 3"0 RGS CONDUIT * 4'-0" 1 METER BANK'MA' v " PROPOSED WATERTIGHT METER C7 HEAVY DUTY METER NAME PLATE PIPE CAP(TYP) - 4 SOCKET COVER (TYP) Y K r\� y�tK CE QIP ESSIONAL CI U ® MPJN O FRONT VIEW SIDE VIEW IT Is A vI oR ANr P LL 1 UNLESS THEY G N 'IIND€f�',if1$`�IR N TERMINAL 8$.37" OF El Em,7GSPk U 1�5 DPDCUM.Exr�� 0 LUGS SECTION UNISTRUT P5000(GALV.) J 394" SITE INFORMATION: CGiv�Q SITE NO:ALBERTSON MARINE 61405 MAIN ROAD SOUTHOLD,NY 11971 N\\o4.i i�.\�%\/%\\!%�%�%�%\��j\i. PP e�c ` SUFFOLK COUNTY IL I IL I ____L - -__ pf SITE TYPE: iii I=iii 1 1 �paCd 150'A"CONCEALMENT POLE 11 II. L------Jrg 2pr` 1 L 1 L•I II 7 r � mTrnucxTo mn.A�IVDL rNcmiE>:Rwc P.c,uD•„ !••.1 0 !'•.1 I I / THrs DR�r"c wD ui1ONE w"�E nw oartnNm HrTmR a v t—v t JI I I / ' wTHaaun PTA usE RLY BiRE Pum PTIR ww TRE / �awc res cwmnmu a+To wou Ir rs cRTvrn.Txs �'/ �INaT Txs r NDwuss rarTDl minnr aE,.mum 12"0 PLAIN CONCRETE PIER GsnTmmm arc EOR ILt.oTIeR PEaa» < H (4,000 PSI CONCRETE) MESA PER-INSTALLED MI NOTE DISTRIBUTION PANEL PLAN VIEW 1SHEET RILE rc I. MOUNT METER BANK AND MAIN LUGS SECTION PER ? CONSTRUCTION DETAILS•2 MANUFACTURERS RECOMMENDATIONS AND INSTRUCTIONS. z 0 m canrtLlc scn� caneNlc scA� s ;SHEET NUMBER: Z-]', 2 MULTI POWER METER BANK MOUNTING DETAIL DNFF£ N.T.S. 3 MESA CABINET DETAIL N.T.S. 4 " „NE,ELT N.T.S. a — — BY Z BA DECISION# `7 c�9 DATED: t 1 L6 I" 4A 12,1" 10.7" WITHOUT FINGER WITH FINGER WITHOUT FINGER WITH FINGER 6; GUARDS GUARDS GUARDS GUARDS ell ? 13} fk,IP re. t Moz! lilts ILI,I ;,L.1"J!, WE 17 ME I RRI ;7 Efft rr gug- 11 AZIMUTH! wENGINEERINE3 P.C. _77 L) frop viewl (fop VA-1 ITOP V-1-1 [Top Vte-I PP 4 15(380) 15.88(403) 14.90(380) 15-88(40351 ELITE,TOWERSLP I'll Iii f1g, g k 14.96" 8.6. z ci ci -'suang zv� M'a—cw F- [Front View] TMnt%r.Mj [Front Vim] [F-nt%r—I vallbonV 4aP 17 r, WEIGHT=59.52 UB SAMSUNG RT-8808-77A P'. —I—TE SPECIFIC�a PHONE NUMBERS View] [Bottom View] tftttom View] [Bottom View] REMOTE RADIO HEAD VISIT, NOT TO SCALE sD.,c oaten AS SHOWN I WASI Jl� 9 06/15/23 REVISMPM—M— JRF JWS SAMSUNG-B5/B 13 RRH BR04C RFVO 1U-D2A SAMSUNG-B2/B66A RRH-BR049 RFVOIU-DIA I 8 OS/19123—mcOMmi!NTS JOM JWS WEIGHT=265 LBS WEIGHT 94 UBSNOTES: 7 05105123 �M PER C�MENTS JR, jW1 ANTENNA FACES =2 58 SQ.FT. ANTENNAFACE AREA=4AS SQ.FT. HEIGHT: 15.49" HEIGHT: 15.49" 6 04113123 REVISED PER c—E— IRF JWS IMAWIRELE MX08FIT265 NOTES: IMA WIRELESS-MX06FIT465 WIDTH: 15.88" WIDTH: 15.88" I. RRH MODELS SUBJECT TO CHANGE 5 01103123 CUENTCoMmENTY jcm jWS 1. DIMENSIONS SUBJECT TO CHANGE DEPTH: 10.03" DEPTH: 11.93" BASED UPON AVAILABILITY AT 4 I2J14r22—INT-IMME— WPK jW1 TIME OF CONSTRUCTION. BASED UPON AVAILABILITY AT 3 06101 f22--ME— WPK JWS TIME OF CONSTRUCTION WEIGHT: 70.3 LBS(W/O SOLAR SHIELD&FINGER GUARD) WEIGHT: 84.4 LBS(W/O SOLAR SHIELD&FINGER GUARD) 05/10!22 I I ENT connR4n , j` J, I G410Sf2II —m� jcM jwS I ANTENNA DETAILS N.T.S. 2 RRH DETAILS REV DATE I DEscpurnoN IT' NOTES: POST CAP(TYP) F I. GROUND EQUIPMENT AND MOUNTS PER MANUFACTURERS K RECOMMENDATIONS AND VERIZON STANDARDS. HEAVY DUTY 2. MOUNT EQUIPMENT PER MANUFACTURERS RACOMMENDATIONS. GR INSTRUT 2'-0"WIDE 3. CONFIRM REQUIRED EQUIPMENT WITH LATEST RFDS. WAVEGUIDE 3.35" 8.98" M z CROWN EACH y UCEN MI FOOTING 2"A.F.G. UCEWAIWIkE�.0 C"E"' 37�1 �. Z 1.0.R-:Y I.NISHED GRADE ..0 U. 0� �1 THE R PR. AL;�� . R_'. c R�� ,qr ENON S DOCUMENT. SITE INFORMATION: COMPACTED SITE NO:ALBERTSON MARINE SUBGRADE 61405 MAIN ROAD CONCRETE FOOTING(4,000 PSI) SOUTHOLD,NY 11971 NOTES: 0. 0 SUFFOLK COUNTY I. CABLE BRIDGE SHALL BESITEPROI GRIP STRUT TRANSMISSION LINEui SITE TYPE: BRIDGE KIT(PART NO.I B24D-216T3)OR APPROVED EQUAL 150'-O"CONCEALMENT POLE 2. ALL COMPONENTS SHALL BE INSTALLED ACCORDING TO MANUFACTURERS SPECIFICATIONS. SIDE VIEW FRONT VIEW GO a�5 3. CONTRACTOR SHALL DETERMINE REQUIRED QUANTITY OF ALL CABLE BRIDGE COMPONENTS. 4. SNAP-IN HANGERS,SPLICE KITS,HINGE KITS,EXTENSION KITS, TRIPLEXER ITT E IT 11—nos ORANwc n5¢L4D. STIFFENERS,AND OTHERS MISCELLANEOUS HARDWARE SHALL BE MANUFACTURER: RFS PROVIDED BY THE CONTRACTOR AS REQUIRED. N ba 5. CABLE BRIDGE SHALL BE ROUTED TO ACCOMMODATE THE MINIMUM NOTES: POWER SUPPLY: FD9R6004/IC-3L BENDING RADIUS OF THE COAXIAL CABLE. TSHEET TITLE DIMENSIONS: 4.6S"Hx8.98"Wx3.3S"D :C,011 6. CABLE BRIDGE COMPONENTS SHOWN ARE SCHEMATIC,CONSULT I. TRIPLEXER MODELS SUBJECT TO TO MANUFACTURER FOR EXACT AND CURRENT SPECIFICATIONS CHANGE BASED UPON AVAILABILITY EQUIPMENT DETAILS-1 z AT TIME OF CONSTRUCTION. I A IL A o v f!!%I -jv1 LA w 121 1 CABLE BRIDGE DETAIL (IN FI—I '-E`T UMBER: 3 NOT USED N.T.S. 5 1 TRIPLEXER DETAIL N.T.S. Z-14 iwi=W*r-'wr—M imllft '- DE5CISION# 36) NOTES: m c LIFTER EARS 37.7" I. MOUNT RRH'S AS PER MANUFACTURERS RECOMMENDATIONS. 2. CONTRACTOR TO VERIFY THAT RRH CLEARANCE REQUIREMENTS ARE MET. --_ n 34.1" 21 3.8" I 32.0" 37.8" 3. JUMPERS&CABLES NOT SHOWN FOR CLARITY 4. RRH'S SHALL BE SPACED A MIN.OF 4"APART ON PROPOSED H-FRAME \ • " " O O GPS ANTENNA - O OOO (PROVIDED BY VERIZON WIRELESS 'I ' • O INSTALLED BY CONTRACTOR) %ZIMENOINEERINO P.C. rT OO PROPOSED RRH'S CABLE ENTRY O (TYP OF 2 PER SECTOR,6 TOTAL) l �P)� I EE O.D.x TIN MAX GALV. o - PROPOSED PROVIDE APPLICABLE STEEL MOUNTING PIPE ELITE,TO�VLRS LP o O o CABLE ENTRY HANDRAIL POST n O n O PIPE TO PIPE CLAMP O 12"0 GALV.U-BOLT COAX GROUND KIT REVERSIBLE (TYP OF 6) 1I MOUNTING �' CABLE BRIDGE POSTIPIPE MAST ,�:. �V�1 f7_O_G_ D KITS O ,® /O COAX CABLE(AS REQUIRED BY -�, p // ANTENNA MANUFACTURER) OO OO O l J PROPOSED UNISTRUT OA00 (�J� END CAP \ ® / I�CADWELD ON POST 6 AWG GROUND 1RE OR r31.7" 45.5" 34.6" O LUG ON GROUND BAR ■ PIOOOT v�onm/ PROPOSED CUT TO 0 0 0 0 NOTES: UNISTRUT(TYP) O/O O ESOP POWER EQUIPMENT ESOF024-ECx01 CABINET LENGTH IN FIELD ®®® I. LOCATION OF ANTENNA MUST HAVE CLEAR VIEW OF SOUTHERN SKY AND POWER EQUIPMENT HEIGHT: 72.0" HEIGHT: 72.0" O 0 0 0 CANNOT HAVE ANY BLOCKAGES EXCEEDING 25%OF THE SURFACE AREA OF C 000® AHEMISPHERE AROUND THE GPS ANTENNA. WIDTH: 31.7" WIDTH: 32.0" OB elow. S CaII am,.yep aN DEPTH: 45.5" DEPTH: 34.6" 2. ALL GPS ANTENNA LOCATIONS MUST BE ABLE TO RECEIVE CLEAR SIGNALS FOR STATE SPM C DIRECT RHONE NUugERS 578 LBS(RECTIFIERS& APPROX.690 LBS(RECTIFIERS FROM A MINIMUM OF(4)SATELLITES. VERIFY WITH HANDHELD GPS BEFORE EIGHT: EIGHT: FINAL LOCATION OF GPS ANTENNA su3F a m: olEaDn m: EQUIPMENT EXCLUDED) &EQUIPMENT IXCLUDED) I AS SHOWN WAS JKM 9 06/1523 R EDPERCOMMEM JRF JWS 8 05/1823 REVISEDPERCOMMENTS JCM JWS 7 05/0523 REASEDI'MCOMMETRS JRF JWS I EQUIPMENT CABINET DETAIL `"^""a`"" N.T.S. 2 RRH MOUNTING DETAIL "" "�`"� N.T.S. 3 GPS ANTENNA °""P s`"E N.T.S. ± 6 04/1323 REWSEDPERCOMMENTS IRF JWS fW fEETI IDV PEESI _ tD+eEED 5 01/032)NEM COMMENTS ICM JWS NOTES: 4 17/1483 CLEIM COMMENTS WPK JWS 3 06/0122 CUENPCOMMENTS WPK JWS I. GROUND EQUIPMENT AND MOUNTS PER MANUFACTURERS 2105/1 05/1022 CNENTCOMMENTS JCN Jws 4 3 2 Inr RECOMMENDATIONS AND VERIZON STANDARDS. I 04/05/21 CUNT—MENTS JCM JWS I.I.ALL E1cTERC DDIDLGCNSIJff N APiL1hT 3L@SK4l NDlE uAiDN��Asa�idsDN°-m."mPc PAarasazNGTlGsmu 2. MOUNT EQUIPMENT PER MANUFACTURERS RACOMMENDATIONS. REV DATE DESCRIPTION Guw.NGPAttuRNG'srccr:REacuuD+rs 04V DD END CAP D PIPESH06.0-) REFERENCF D 3. CONFIRM REQUIRED EQUIPMENT WITH LATEST RFDS. C O C PROPOSED UNISTRUT EUPKIVLMO 1md.s-OOM .( G- f /Y L 6.5" c� PROPOSED 1/2"HILT]HIT-HY HIDDEN IN DETAILA 70 ANCHOR W/3.5"MIN. O O O O O O t EMBEDMENT(TYP) Lrtl LrV E iI C S C ^ ^ ORK DCT FsE531 APPLYTOROUE rC. -LIC ENI) 1:.09534-1 PROPOSED ELECTRICAL PANEL ' �-� wEla (MOUNT PER MANUFACTURERS ANTENNA SHOWN FOR ,mii IT 0 LAW FOR ANY P 5010, REFERENCE ° UN EY TING UNDER THE DIRECTI�I RECOMMENDATIONS) OF THH ..Lu�EH+TMSEDDPROFESS DNAI IS SITE INFO MATION: O ° SITE NO:ALBERTSON MARINE g g 61405 MAIN ROAD SOUTHOLD,NY 11971 SUFFOLK COUNTY COMMSCOPE,INC.OF NORTH CAROLINA SIDE VIEW FRONT VIEW I SITE TYPE: GS h1fC3731B 150'-0"CONCEALMENT POLE G12 ! Mvaaslmwlmeam DIPLEXER i maim wgDMDa.r�+al"a vmAmNouwr � •mw PROPOSED TELCO BOX x onlm ANIwwNauNr"RA mT 3 r '"� mPrwcNrou+n,nmTvrNTiucaveERDuo P.c,tu nu a N'' vLLVBO1� NONSRI AZU9rtHANTONAMOUNT MANUFACTURER: RFS wcNTsaPSE— v MOUNT PER MANUFACTURERS • Arm m EB' a A TNa DRAv°Hc Arm NE n¢mraaAnTrH ccarAxm NomN a ( A e mmtb FWYGNVBGLTIGi r GWIGG ,.. Ii1 ," AUMOaIID EOR 11g md.Y 6Y-E PAa1Y ibR TaON DIE a, RECOMMENDATIONS) POWER SUPPLY: FD9R6004/IC-3L IIu«rAs mHmACRn caro a IT IS aRTo-na nGs ppFp gU�nl6 WY NOT BE G9Rm,REUSfA DSCIDSID. 911 ®®,p° 1:6�.e,. MTC37318 D6TR®wDm Da aDrtn uPox Ftlt Aar oIrDR Rnso2 DIMENSIONS: 5.8"Hx6.5""Wx I.S"D T THE DwaEss warTOH m/nTTr of Amlum oPROPOSED PI OOOT ©ar .� ve C ®� Iza daramwc P.C"uc UNISTRUT(TYP)(CUT TO q g .aM 2 N I•w.N NOTES: WEIGHT: 2.6 LBS SHM¶ TLF- i LENGTH IN FIELD IO I L EQUIPMENT DETAILS-2 NGE BASED UPON AVAILABILITY o T TIME OF CONSTRUCTION. SHEET NUMBER: 4 ELECTRIC/TELCO RACK DETAIL N.T.S. 5 ANTENNA MOUNT DETAIL D I R D"""a`"E N.T.S. Z-15 —awe It DECY51ON# 3 AUG 0 9 2023 -- --7`33 Zoning Board of Appeals o_ N Single section Multiple Arrays f -__--= xaa- Pmsuao unlaoF:ooa w.,Tr�ar mwamw.a baaFawaF.'mvdua, I N Omb w �bO n{i 1J -' BfBAAANN<Oaa+i1OeDvG$rr x[3®Comnm am,tepeTae teem 'LNOBe-S+ffixvddnHzz cOrWaoII,a,iP S �iSSrmsW]b 0.--�•nS6SgnSarCcA'saae¢DOenbrsrsmTxAZJ:s'gJ 9pNW.eMrt PrsNmmMsmlIasvLriJN,^lv6vastlbmY"IDa+apWu/aacwr9HYsTlm.lxtP4aSmSAl®ltmNVocYIPe dYFYRnl mwr, mtm EIvnmmmlww PMo dB hvm Oranm°e eInt ."'snEOAZIMUTH iE oAzozo6r z.raee am°m.tmaePmma lane . szwH: maamm„unxm.1,e.ter„m,.me e�wca�lomoaa.Peom�y®eaxmem,e,nn:mmmm ENGINEERING P.C. PTPtmww.a..° 1RazEEeRoray' Itonft� nl G _ n Olw6i53FnW3 elbxvrsbaN,v4sa� a�WPte,®¢ tary-in axvlmn> ° Dual section combination Dipole Arrays r„Ex, e mrnPa®(alsslwav rws.cmnarvaazl _ rIs J EE P°rtnumhar— pasW[Nim, F - = --- s Nsu'+unfisvplan%v[W Wm]Imve C�omIIC3v �vxNm wenFP'l.StSm,n�s-i.PoWzaimoSl C x, Om.% - SMFN6a➢W IaNasEWbI61JawMAMtrtlmsas<sttiiedaC3artnncmie"il,mY m°d<tlnnE,u¢tlwaWm �� %W+IaEWICU4159S IWufaO!'eit ENS BMwDSn xzaam vmJs"+N EepSrae beCs 8TC-axeMMi �� •^�m,EWATIv'Ti°'1art°sayT° fmrtlu�JOW.iIYa(606D0[Y'ot—s EASOSn ixbleC omn al0-exOMM[ F $ %r@-seac— AEBmM,S✓NCu� a4u1A1NGiWH.OWF m.YPF(AO•@4lxmtmda,artmtrn ELITE T0�1'<ERS LP z[0®E°Imla.xnsn,e,naleeaa N0040MHt , �__i' N.uMrIOUBCIwoxoSOrcH iwRm°00.e MWa Naavmrmuroeamtm/ReFalry MSeyialmnmimS°CUIWNFrpm M*m D'J1FwxiEAp)NpMPpplaneN P65sNCA 1'" mmurw •sMwau,w,x ExFsm °j eAman e®Eenw NOaszvua � mr-1e 1a=ao,am,awom%n mnSPsnswlwu monm��u oc'o eaalmss AM1-Icv6aCPavNIa.vb DCS YaazamSlOeab�LL-nfCY a[atetl�"9vim'6T Y.ottlo-al rx m.-1{' vwx `,-sse. ranamxir 1®omvm i p- _ FANwasn z.saea amlmmm.2l,ewawaleal, aTad2aeHT j rmdlmma�meaerosrs:xa,N u�6�am1x•fm'm•m'¢sPo9azNav:.umm -_-"jj __- a�.A srrmmaro'sauIsb�aorm�rmmo =A "1_R _.F: EAE0.AL lz 9CeE aap Sw-FzoMN: i��0�nmvII�nmea�mn�xaln dam:aaWm-tla¢rM.marermC.osy.aaoucmr K rc rsrN<n uvr(-aTm.wanNwxo YK�wlu - + _') T FAfwOen 2[6CBE CRC6rela w,L,seperme lags NOOSaMM assam¢lbolnpdz CULCbva4cCpbmwtl,a7 DvecbesYa1M19.3-PWmm)M+yNSY(40,sa),GS:YB]m:ry "�. •-_ $�� :4� Braden lx saeE aopuwi Rte cmuma.ew:m wwmmxsuPnon mwmaaam(wmmwmmem3mE,mren.mvymo ! dS' _ on[n samare wxa wmmmlmaosmE - _ __ �GxE RSB mR max of aNiBm�B ma�Na S` OIiTHOLD`° oAzezv6 z,6EeE v:eaa„m,tePmammays mss.4maP rwlwiaJAwwm umax�lu�;waAauno 6®s0lmwm,EmldYtl Imo.,_.._'__-_�"_�, �• OAW6ns 1a9C9E CSCn N0055ASHx ��m� F,xpO s9B¢rt[Pa150[RSm s A � m L•�s��.tem:.Cnh C Genn abaaare lvwr�brsanrnge 0 stCUEea aarxlgnlamce%m mwm Y01a tll0beb UFWarsmbn As0lasSgit zsars¢w scnecaa01¢m1I¢Ie nvzNe FaeEBFaSS VEvraaxee2vPafm 9Nwanmv wYasozB.sesrBnwaxvmaaLur,�aEmr®or 6 sem yTx"vppn section Ilan our rmgemsmnderd UHF AIm/s .� _ YAmn.,cIM g a E�.OI sailon mmbinelwn eoay you..novo.on c on lolbwn ° E 1.Spmtyyour Se onhom Ocllstehaeeg BABUan PWG 1Rp1f' lesm,s H 2.Spaciy Ydv zm,geurpa—finl eo:nten rwgv 0l M.vadmd UHF A-11 IOWDN1may,)e{Nn Orme%vub�nm Wrmm m -aznleec:.e. vxN rn'caxm-ymwms/mRreamst�elbemm:rwutrmtysanwee.. unmmlvemearcremare m�iara«/mmFmo hmvael ee.lawdam%lomsareare..Mxeaaruloynurslm'maasaarv:mlmaelmw.z Combinadon Collinear and DlPole Arrays mr%a�*Awmmrea rr,�amammnomv,aPoraaee:rememma�l Dune,vervwnaseEanmtanvayas�dnomrzoYxlmaelmrce N - nd LsaS VibaSEgm •w'xsereawHrlPS/ILSSM3zNen AES<vOkEmEx OmNavercmv t)mnaltlle[NSmee F+�eracvnmamNNawUa __ _ B%Np6x lza0e4anay5afAlk Dtmu(T 1-rromedvNemmaxy _ I exawo6T xxa®avnwawm,aapmmolaam szmENT Da eaxw -J 6Im067 1z6®ECmtl NOOseMaHz _ -- I niRTOAt£1GION IAmlvtllsNSRF0sl1 CFIn>txl PsM ®Pani sealaw F:o¢T31'f'NLKr erma(:eSlxFesxRevNar•8 - _ __ - SDA 1N'd9E elaDzvl �SxOMNz - mO15TiN8VNt ryacsraCeSemtlEff� _�___ - � tMW Seco 2 FaBE°1z�eEBE W' i� .00628dHz i0.Vf:4F50."+f L+rLi�aamp:6roCM www', PROTECT Y0UR5� REeaEw a �rLa`�PoEF�mPc I elow. --. -.,'�__-'s_ t 01(x0206)aw xxsEea olmetswM saP+l°betla iWSxOMHz rs rtPoM128WJtl PoFutCNttv %n asa.,a u,roa s„ar[m¢ - ..' Callwra,. nvrmanaxal e[nelANnma+laM,aue:Beunl n°Ea Reevl rceodone efin—wMCOLeaioncoUncen.They arepmiOool Wit, alga nemms to Dvnectyoa rdl0imol rJmmA Dwp FOR STAIE SPECIFIC DIRECT PHONE NIIYBERS NSI):M11yCCAf1E11.LQ1 --_ _- COLB gktr],COL-15(YHF]a WLiT O'HF)mrmeas. wra.aalmgx' sah•SemrJ x]wwroy oTN ce: Wnen ortlOEg atvnbnetron w0rsareM EipOm a^0YYm1 NN rxiadb oeOsr es(d'Ewa: nvumzT(x wzvJ m3iv�7 �.tdsGl,dlxm a1Vnm¢amaranN Svn�®tr 1.spaatyyaurlwrerSection ban the 11)e50.e y:81®0-67 PLUS M.AS SHOWN oRA WAS m®f KM a � 2.Gpemyy0lr CALr'Nllrea•OEhm COL15,COL1Trr COLB eg:C018(end zameinOar to SpaCEY h¢qumcyd 9 06/15/23 REVISED PER COMMENTS JRF JWS O 8 05/1&23 REVISED PER COMMENTS JCM JWS 7 OS/ON23 REVISED PER COMMENTS )RF jws 6 04/13n3 RME0 PER COMMENTS fRF JWS 1 350-520 MHz UHF ARRAY CONFIGURATOR DETAIL 2 PTP 650 FIRE DISTRICT EQUIPMENT DETAIL s 01103[27 CUEN COMMENTS JCM Jws 4 INI4n2 CLEI-COMMENTS WPK JWS rLL, x 3 ONOIn2 CUENT COMMENTS WPK JW5 2 05/10/22 CUENr COMMENR JCM I fWS i - General Inside Clearance-Less Rails 1 of/osm cuwrcoMMwrs JcM Jws Weight Height�_- REV DATE O.2051bs.assembled -77.98" NB .2751bs shipping weight Width { Doors -23.025' •2,semrted by three point lacking system Dept .locks via custamer supplied pact!coke .See reddng apedfimti0rs Sealed wM.875”aluminum filled gaGimts _geeable depth Material . mlfiex® /2[26095 Ftnlsm PElnted cream NEMA Class Types available y 1 ( RF pmperdes:Non-ferrous NEMASIR(Vented),NEMA 4 3 Venae (closed loopa/c),NEMA 4R i 30 bottom louvers per door Paint Tested I 14 top louvers-In topes 1000 Nomsahspray(telmued) Alum underLsMeld® -1000 How immersion •One removable I tter panel per door M CKE(� I .14gxedfitterPads to top raver Door Opening Clearance I Handles Height a SED PJJ��g(�pESSIONN L i Srm,padloddng -74° N - SE NUM9�R:0 1 e Raba -195 IT IS 0 lAW1FOR•A}1.PERSON; , ' Racking Specifications; .795' Tyro Sets ION Rd standard ExterfOr Cabinet DfinellsiDnv UNLESS TH TING UNDER THE DIREORON gOr addlti0nal relb sae 8mx950rie9) Mein Body OF THE RESPON BLE-UCENSED PROFESSIONAL __- Alodins Coated Heighe78.23" ENGINEER,TO ALTER THIS DOCUMENT. Holes tapped for 10-32 threads W'Idih:255' Fachreil supported by three R-STRUTS- DePBc 34° SITE INFORMATION: .125"Materiel umlR (Nai Alum/shleld® Sparing Hang darn height:1.71° SITE NO:ALBERTSON MARINE •79°er 23°Racking avaDabie 4YIdth:28A5' Useable Height Depec 3657' Usable Tacking height has bean revised Handles 61405 MAIN ROAD to only B N the opening of the doorfam Protrude 22° v, which is cabinet height minus 425' Total Space Occupied SOUTHOLD,NY 11971 •Maximum:7425" HeighC78.855" NambaretracicuntteparrelleBe42 Wldth28.46" SUFFOLK COUNTY Tatzl number RU's Up to 84' Depute 37.75° uMaiimurE°as Minhnum:28.75' SITE TYPE: [ RECEIVED 150'-0"CONCEALMENT POLE Top 74.TS-7823-- a9S 30.Sm COPTRIGHr0 a,20,gIDMHII:GCiF£Patb•P.O,ILCA11 aOi I CIXmACa1EGD�to3�TO e�tw� T4T-7915- .18- 290•_ wWIDRALL aAUG 0 9 2023 USQaPAIT omrsn rttnA_eramn4aMa 45.60•-74,5T 295 30.k- > 0.P> ra TwDte 6 Canter 331)V-45.60• 14.00- I 28.TS —721�1 i y4mW 111E yEM��C�SFHT 6 AIDsuM J CSf1.7a.I1FD Ori IR1ED IIDR!frit ANy OnaA WI80'E 2 F1plt and flair seta 0f rails allow some ; -3�-344 � - as. Zoning Board of Appeals SHEET TITLE: a equipment to rade but directions providing mom f 0.00•-326- � 3]S MEW w m e4 RU FIRE DISTRICT EQUIPMENT-I • m RA A MISH ET NUMBER: 3 OD-78DDC FIRE DISTRICT OUTDOOR ENCLOSURE DETAIL 4 NOT USED 5 NOT USED Z-16 Y ZBA i DECISTION# a n ITEM PART NO. DESCRIPTION QTY. ff 1 MTC79020808.01 8'CENTER CHANNEL 4 8NO7ES:1.0 ALL METRIC DIMENSIONS ARE IN BRACKETS. 2 MTC79021010.01 10'SIDE CHANNEL 2 1 3 MTC7902.03 CHANNEL ADAPTER ANGLE 8 4 MTC79020810.01 24!'X 120"BAR GRATING 4 142.72 LBS 5 GB-05205 5/8"X 2"GALV BOLT KIT 32 0.07 LBS6 5 z 6 GWF-05 5/8"GALV FLAT WASHER 64 0.01 LBS O �rl `I T 7 GCM03 GRATING CLIP 32 7 ' ,5 17 enio1nleeF3lnIO Pc. 1 - 10'-(7'[30481 DETAIL A ``"/ , •� � �� � ���� T A` DEDI!iA5 I• ALL CORNERS ELITF� QRS LP• un 8 4 �\ SCNEIE4 12 6-0"12438.401 Im � fa- 6 Tj✓ 13 � ���v SLATE I.1 ITEM PART NO,105 DESCRIPTION"GALV BO piY. WEIGHT NOTE NO. ~ �� I GBO3105 318'X 1'GALV BOLT KR 14 0.05 LBS 1 2 GB-03205 318'X 2 GALV BOLT X1T 28 0.08 LBS 3 GBQ5205 5/8'X7GALV BOLTKR 28 0.260S 4 GWF-03 3/8'GALV FLAT WASHER 14 001 LBS j 5 GWP-05 5/8'GALV FLAT WASHER 28 0.06 LBS 6 MTC396620 POST HANDRAIL 14 9.96 LBS 14 PROTECT YOURS'ElF 7 MTC3979HRI I HANDRAIL.ZRROMAL 4 16.60185 8 ARC3Y79HR12 HANDRAIL HORROMAL 2 21.11 LBS Y 1 MTC3979HRt4 HANDRAILHORIZONTAL 2 5.41 LES RECEI7VED _ 10 MTC3979HR15 HAIATE MA DRAILL.HO OEB AL 2 16.51ES LB l] MTC3979HR15 PLATE HANORAILTOEBOARD 2 16.52 LBS t BIDW. Call6 AT SPE _MO[228.6] 12 MTC3979HR17 PLATE MHANDRAIL TOEBOARD 2.45 LES FM S A E SPEC FlC DIRECT PHIXE NUMBERS 13 MTC3979HRI7 PLATEHANORAILTOEBOARD 1 6.0.5 LB5 M9T:WNN.CALiB17.WY 14 MTC3979HR18 PLATE HANDBALLTOEBOAR0 1 5.37 LBS 0 IS MTC3979ZR l ANGLE BRO.HANDRAIL 12 0.32 LES AUG 16 1220 12-24%2'SELF WITH NE PRENE 16 0.03185 AS SHOWN WAS JKM 17 IDS TEK SCREW k12X3/4.WITH NEOPRENE WASHER 48 0.02 LBS n`� J (7,(J 9 06/1523 REVISEDPERCOMMEMS JRF JWS (• Zoning Board Appeals 8 05/1823 REVISE MCOMMENTS CM of App JWS 7 0$/0523 RENSEDPER COMMENTS JRF JWS 6 04/13!13 REYI6E0 PER COMMENTS JRF JWS 1 EQUIPMENT PLATFORM DETAIL(COMMSCOPE PART#EQ-P0810-B ADA) 2 EQUIPMENT PLATFORM HANDRAIL DETAIL(COMMSCOPE PART# 3979HR AD A) S 01/0323 CUENTCOMMENT6 JCM JWS NOTE 4 11/1482 CLEINT COMMENTS WPK JWS 3 06JO1122 CUENT CO-ENTS WPK JWS FINAL DESIGN OF PIERS TO BE CONFIRMED 2 05/1022 CDENTCOM L CM JWS REM NO. PART NUMBER DESCRIPTION QTYFORMTC4045HF65 QTY FOR MTC404SHF55 ONCE ELITE HAS PERFORMED A 1 1 04/05M 1oM I GEOTECHNICAL BORING AND PROVIDED REV DA 1 GB-05345 518°X 3-112"GALV BOLT TOT 8 8 A REPORT. 2 GUB-4355 1/7'X 3-5/8"X 5"GALV U-BOLT 10 10 3 GWF-05 5/8"GALV flAT WASHER,1.700 8 8 j Ar V F 7✓� 4 MT50460 SQ.SUPPORT RAIL,1-5/8'X60-LONG 5 5PROPOSED PREFABRICATED 2 d 1 1.0 GENERAL 5 MTC4NW WELDMENT,6'PIPE 2 2 E MTC4095-02 EQUIPMENT PLATFORM c _� >¢ NOTES: E LL 7.1 AUL'P'A IC0IMENSIONSAREINBRACI�TS fi MTG4045-12 BASE PLATE,3'PIPE 2 2 SEE DETAIL M O 7.2 FOR PA TENTS,SEE WWN7.CS PAT.DOM PROPOSED ( ) C7 f 20 DESIGN NOTES BASEPLATE k I� 3.OMANUFACTURINGISPECW.REQUIREMENTS 7 PC-034 PIPE CAP 3-117 2 2 O C 50 ACKAGING 8 PTCR01 END CAP 10 10 - - m0 60 011524; 7 I- 351891 PROPOSED P FESaO7L'A SBBiI270J r- -"'' " 2 -(,'1 HSS4X4X3/8 COLUMN PROPOSED UTILITY H-FRAME ENGIN 1$' �' SEE DETAIL 3 IT IS A VIDLATON OF FO�EN !ON, UNLESS THEY ARE ACTING UNDER THE DIRECTION 9 PROPOSED OF THE RESPONSIBLE LICENSED PROFESSIONAL I<OI356] 10"XIO"X3/8" 1-1/2" 1/4" ENGINEER TO ALTER THIS DOCUMENT. TMP BASEPLATE rrP SITE INFORMATION: o e oeevo ......... I 3 GRADE LEVEL SITE NO:ALBERTSON MARINE PROPOSED a GRADE LEVEL B \ PROPOSED 5/8"A615 HSS4X4X3/8 61405 MAIN ROAD 0 - \ ANCHOR BOLT COLUMN SOUTHOLD,NY 11971 5'ORS EMBEDED 1'-6"IN PIER PROPOSED AVA ABLE (TYP.) I O"X 10"X3/8" SUFFOLK COUNTY •. BASE PLATE ' vee------------o------ T.; ° PROPOSED PLAIN CONCRETE PIER o (4,000 PSI CONCRETE) 5. PROPOSED PLAIN CONCRETE PIER SITE TYPE: 3 1 (4,000 PSI CONCRETE) 150'A"CONCEALMENT POLE veo 000000000e • PROPOSED 10'X10"X3/8"PLATE ' COPYRIGXTC CIU,AX EELRIN4'P.C.IlGg11 RIGHTS-RESERVED M6 OMTWO ARO ALL THE HFmWATm1 CMTANFm NtTaE1N 6 1 AUMOEIID FOR USE mLLY 9Y THE PARTY FDR MHLMTHE I'0" rAs m+mAcrtn OR TDa H IS�LTaaa RFS mUYWO T BE-M 1 3 RNSFD.DImP3D. > I 8Cl2W6 IT Di q OISR�®UTET GR w2"NOR EXPms FFeFtlt OPQR DI-` T THE TDtP.m+sET+T a AIDIUM N w �91EEr TITLE z i '1 a FIRE DISTRICT EQUIPMENT-2 s z 9 EET NuuBEx 3 UTILITY H-FRAME DETAIL(COMMSCOPE PART#MTC4045HF) 4 EQUIPMENT PLATFORM CONCRETE PIER DETAIL 4 UICRETE PIER DETAIL Z-17 EVI DECIS10N83 DATED; ILa) a o NOTES TO USERS conG LEGEND maD Ic br o .n aem,maerinp the Whom F�wtl Imm�ow P C dws mawanse Id� yawl areas,Mea to Mminy.pMAVIMy II�a,I IoW /S2/1ND ZONE X ZONE X ZONE%�N�)'� Shl� FLOOD NAZSLD MEAS SUBJECT TO B)UN)ATTON T. unify map npwkdy amad d, SDUND 3roop FT BY TTIE I%ANNUAL DIN]CF FLOm �I ZONE% JOINS PANEL _ mrsdlaE rd poaada uWaee or ao,lsiona nom wnm,domabn m,ebf d-vama naM p'w'yea.-. nWCF®e�ams 'O T mla eaabe n 50ro FT � Zs ass'amex mrpmrt'M��eruaamee<rlmJW pwenme atmrmltbllsa,4 \ Morr,wLon n mess W,urs Batu Flood Ebrawnc avzz7 s °is'x dx'N �BFEa)and/or nooawari nave y 0 tivermned a are mmv.ped m amau, MA"""aos red Ni'iu a�rwp vmmM VE TM ea Fmo FI m e de xae.-sr:r� m Fom PndJes am F o F1 J pea endo,Summary a,SJNmer EkM ares ZONE VE 5' ��I taobs mma rod within Me Flme nwrance bYud FIS ARE Y( 1 repos Mat amnmpanss rZ tn,FqM Uawa ehoula W acne mat BFEe Mwm m ne FRM reDMaenl INCDENT UMODRIE ZONE AE J-J - rectae r-rpa eeYationa rne,e BFEs arc,nrcnded Ida none nawanm wluraoadrwDN SIIdiF.IINE +;� - L<c?.oN zoa.a pm Rrrmoa Wen.Ia� - ffi roti n pre pmea pre^.A�rdana,d"ooahe,sea es�lw anI am m d�nom .on,mor npmNn n pewnhd,n 5 ZO1JE X mat An kn Ime'v a�d War.:as am,' rtrWlmmiumdo IIaoG oma juralmn wM Me�IRMeIv Purpess-s p ZONE AE ZONE•AE zMl O x ZONE VE Zo.B An dam.aa. ENGINEERING' LL r p I,a{pned. " I ZONE•X - ar(baa a aw,M � NEr;o A ZONE,%�. am,w e"®mareL 3 ry roaw9,vavnes aw Coawa Bas.III- 6w -(BEE.)smwn m MIa map aWIY mly )y i l� 20N X •' '�, IMdwad d D 0 Nath Ameiwn Vest Dab d 1988 tNRVD BBI Users IM, iAI s t:. w./ /UAE AN mesw ams roan A,w'o,mN pati/.Imm me is amw awde Mfr FIRM Mole b exam Mal meat)Aom ebve4ma•re am Fmwd,d n tree r ¢ss Summery d Sh weer E.-ha ono Tremas Dale bbm n the mtl Inwmrs ]ONE AE bmeA,mcved swan mawa>omamvommnm.m Study Tepol for TtN'nsddan Ebwhom 0 n iM S,mmary of SSIIwa'er ��mV,epe1p Ods vice prmac� Iaomr Elemanm ane Tn ELITE�TOWLRS D,h edea Mead Da mad rd.nada..eons ma to merepenenf purpoxa wleT Mey ae nigher /tare M.II Me aevapn,Mwv, , Amer ,^0b mW"W'• m° FOOd B^bO' m b F RM N " `52�ry ,a¢nwte dee rwlea bx - Bpmpans al Me nmawri wem..pubo a voa orad.MO demoam ZONE.AE :� f+° c xoav ��.eovv n � ,cal sac(wwe amoq.m Me aaK - Oexeen adv setlbna Tile+Rddwari wart D lh m by P c mns1-., '{A ;. i0av[ Cma nom>02 wan aaory nmlU(wx am.),be Nss. 1 r'��J win all m mevre t d lk N 180 Flma Inwm,R Proprarl.Fbmva 3<0000 _ 3 a Shama and otic,peTOnen[.00dwry dib art provide°b IN,Flood Insuhnc, ZONE% SbeyreWnft, ceps AaE7, FLOODWAY AREAS IN ZONE AE idalu nadmdn. - ZONE " Lsae'caas LFeane)"" >® nMe dti aro.dusmvagaanefuagsana�aa•medlmtkc r �- •`' Chan aces not n Speaal Fbm Hand Area mry tr prtaep.d DY Rmd - ZONE V m i a,�d.,vltmsmbeamawdw.ssmea„uw.e (SOUTHOLD trd arvcfuna.Rav m Seenn 2a-Flom P,dal�m aBaaurac,Me ,iter - Fl macre..Study¢part M rdonnation on Rom mntrd armvm la �� .-- Im ZONEAE OTTER FLOOD AREAS f - - I Fla pm1.Mm used p noNpalenpal hare d-T wx,New Yolx sae nmc ti zoNe X - -- GOYE zorcx aNM+pi dam a,v awQenh¢ dLr;a.:�e` b:+m."� I: I,/ J -J o BD-aa� ,¢vise. a w�Pannd briermrrm,w awm em¢bad PszoNE aiw.Tn. . dream w,p Glsa Snap zoHEx SAYE a..roN Osertroa daun a1 J. pmlviRrr or Sae Plane so,I.1 Ingo n _ OTfEA ARFASad �-'� P—of FIRMA br atljam,l lu,bdidiom mry,emlT,n aspd pmborw Z•NEX x vml,wlmbo�IDhme d2k ammicbmenooblan atteremea In Tap roads acro:,rvnadobn bppnWna rew dErere,m,e. a" zorE Nm,ea M anetl Me actuary dMix FlR1A •-_.��e"o" ZONEX �a 2otEp NYaIn NKhnmineffibde ubvsmnr{dn od9en Flom ebva0om on Ws napora,aerenwdto McNMh Ammwn Vs,Owl Oabm TO i.Of d 1988 These hood a dl Da mmparcd b w and 9-1 WASTAL BARRRR RESOURCES SYSTEM(OKS)ARE0.5 ekvetioM,elaenl¢d b k nsarna s... Wpm.Fa/dome.,epadin6 OLIf0.WI5E pROTECTEDMFAS(DPAa) veru�n _ n bewssn MetNarnnamGeodetlr Versul Oaam of 1929 ane Me Nadh Ammcm Verhw ,p�^v, a Natuna:GeedaM1c Suvp ryas e• aMevalmdmSbcel rtdm Nm,c Aga websites hW/Avww nO, Ian Me Natbnal Geodetic Survey It 7 ZO q -------- r.uaidwrelmManm,raaY e rotbw,ry aaaeav ZVE ZONE AE m c ZNE o.7xa uv ren¢nmWan m,cmry NGS laamalan Semi a�, Pom.wv yum NOU,WNG912 A d A -—— IDmO mwm.yry Nabna GemeSc SurroY ZONE AE ............... ry SSMCF=.aWAp2 _ M.�,M, -� 4 � � PROTECT YOURSELF Sher Spnrq.M.Y-2.1-182 J �N,. :-1!T1 r;N("CK MIr cF MDOENA '-wm'a""raewd"m0„mavma NPm,sae AmaaalX•r.bw � (30117,33z4z �00� dmmanPaw,¢be- PO:N'D� _nCPON ON E To mbb cmars Neva6m dacrlPbpn an6br lowhm abm eaen br Dench EtEI �'"o vme r elow. marW shown m th a rrep.Pba.e m,Wa Me Mbmelon Semras&Mc, - ZONF VE Yui^m"aN,owm . d la vin ct a sayer a t3a11 T13J2R d xwl'ln weeae a• `.: 1� - srz------ yaw F,x Ba�xua as Call--,.. RL a00 as Roe B.vs.waa..q.,,wro�m�n•eva may FOR STATE SPECIFIC DIRECT PHONE NUYBEAS 'f: ^ MST:wrYLCN11111.00Y Baa p Nv Shb ha O d a Cy do Ms FWM res IXa1dM In dybl lomat W Me - Z NE AE _ _ aw Cyber SOmnY orb Cdba hhal—Coad®on T.Iddm"n via dah-Urn a pb oMedm,oaaM prm„I�a a 10 p'tirel reaawpn lmm phd-M,rice trod _zoNE) _ zBNWIF a' �0 u.A d�ap.m AS SHOWN WAS JK Razed m uPdaad bpop'aphc nlam.hoA N D a %mde xwbe and - - o---- O am uptodale area.charms mnfipundpna P n dalnaaspns tlmn I ZON q - ZONE VE �Cr nT•pT'I5,32']T30- Ns me'a„`Lvn¢omtro rate mane Dmm 9 0611 5f23 RENSED PER COMMENTS JRF JWS Mow shown an Ub peaou 11M la INA I Was A a nwt iNdt9"emi lNap®)wmvnnnalve Pmfibs end FldoOxey Data odes/a Tee Nomwal B NlaseplolP'e RNer n 98 CS'I8R:kEVISED PER COMMENTS fCM JWS Me Flom lnsuenw S."Repos(•-.--l.sM 4aivaI aha-aa)may '� ZON X DI N '6'-`N -mm le Mm1 abeam.erne daa•wa Mal dbr Irom -----p MMeoavnm ontopfaairod�.,amnemrtleOmM W Iv uneaxd arcema Trey dilly M1vn wwa-s _ -20NE% - -�ag p _ arms <( Erpnvml rprcvu+e POM•o- 7 JRF J W S 6 iGlinSED PER COMMENTS FRF fL•V$ Cdpdab Ymib Mown m tree,mp v"brae on Ina baa timmuNry dTbas m vMry rurJmantOmea pcouree be mamI m�lcm or dsmar or OXSp a P ^N )la daoammaa iK eabeml n Nxv m:�z ams a(rrn 5 01/0323 CLIENT OENTS fCM FN'S medmEl.. hd,taro/,Tawmpm-hlR,=.hsOdd-,a==P¢IXa4 1211422 CIENT COMMENWK JWS lv tl- rclerbMesew,aay prem.YR lrtlea en overv,r map cnwnnp DNEiAE _ Rw�bl MPRivaa••onrdw ind. M"ewa)wd dmap peed raids lurmElmm a ,` EutE ;rnrvvaOE 3 06/0122-ENT C— WPK JVV5 Tie AE Zme w¢pory nos bem dMOM Dy a 11mR of MoOaah wwa Acfbn _ 4 ZO EAE W s�TMaSunAv��Rn7E w,P 2 OS.r1022 CIIEnIT COMMEN73 JCM JWS ILifdw.l The LAI WA rWraenb Me aWmzmae bndwd tun d Me t 5-0d ZDNE AE 1 ZON e�VE - 2 NE% FSB' ZON AES n�c,DpD J ZONE VE N+r"sae I 01/OSRI CDFNTCOMrRNTS CM JWS Di N wase TM eOeCs dvmve hmaW baween the VE Zore Md Me UNWA ONE E DP.AvaTl NECK e M.r,MwA I.a.a vinare vE zm.are rel +1m9 %°"srt .r REV DATE DESCRIPTION BY er I.,ba-ah Ma.haeme ah .,�.'• .r .m.rlNd,mw, mm5ea wll beam Mrso bus law aevem Man Mae In I.VE Zone. n m+A•.,,w.mmvrw•m. Fwoe¢ - - Cmbv Me PEM.Mi S.M.Cada,a 1-000.3ES.-lo,derma.en 335000 FT I'OF' Ue+ oa••awp,ewn^.seemmr nvam,amaoe•aAewo.,wmm alil...P—aaamabd wh,Bis ERM.Ave lade PmMch nay ptllde Z NEA[ .G"IO:N r a+audY ieR,vf_Mea d MqI CnMOn a F om nwnr®Suet repot.erdbr ZONE AE Pad y F NE dips sal 1 1 d Mb nap Tee FEMA Map Sv,1ce LMIe,reY also De IeameeR11 -- m aIn ax'm,'.Y,m'tzi pre verarw r bYFaa+.000.358-SQOam eawebab al Met Nrmclemapw Pi)\LS ,SI(/'7t/•%����.l gwn.vWee Navm Fmela mnnt�ma>«d S wdaryh1M haFvEe MRAww...b.et..sbNmfylxbww.+aha .. � K h...Pmb pmire177 ] (1-77-336 ]aM 6°• mIDanaLOCATION OF PROPOSED WORK 1-0 COASTAL BARRIER RESOURCESoNE yE ha R, y SYSTEM(CBRS)LEGEND — zoNE vE j o ZONE AE 1 19.3CBRSAma ZcnEx �f O PANEL 0159H P_ooDINSURrW(£NOTAVNLABLEFOR STRI.CTURESNEw1-Y6)aTOa su°sr7wrlAUYIMIno..£DONMAFTEROCTOSER,.+m3.N°ESI—M •• RK I10EN L✓D P$pPE$SIORV� CBRSa— r,� FIRM I -� N p�R0953741 �',�.}`" MJCF NOOERkiF �va 11-1&1980 MRS Aba w'rvF aGnG < FLOOD INSURANCE RATE MAP - FLOOpINAMANCENDTAVN'Ar�FOR STNICTURESNEWLy BU11.11 LA11 FOR MY YCttbM, S)B9T.MIAUY ILRtOv1:DONWMER NOVESBER+6.+9W.IN -- ° `ra " ZONAE br SUFFOLK COUNTY,NEW YORK UNLESS yl1G UNDER THE DIRECTION oEM(Y1AlED fBRS aRFA6. 20NE VE ® (ALL JURISDICTIONS) : OF ENgN AN7FRCM5 DOCUMSED ENT. `"a.L� TowO of 1L16-0N1 OIMrwba PrdeaM.m(OP.) __ S ellerI In Y CONTAIN S -- Z•NTEAE O SITE INFORMATION: RDOD IN6U0.ANW I DONOR FOR SJRUCTURESNEWLYB11LT DR B supsTANn,aILv IMMRD.tDONaJ AF,sa NOVTOaER,9.tw,IN COMMUNITY NUMBER DESIcaATEo oPaawITHIN THE cBRs 20NE x ZONE X SHELTER ISLAND, 360609 SITE NO:ALBERTSON MARINE 11-t6ha.f CBp..w. _V0J ,o P- INBJRINCI NOT AvmuBE FOR STRUCTURE NEWLY LaNIT on .luwir;,sTE� �• TOOF slBsrANnNLYIwiI>rEooNORAFTERNovEYRERts+9wlN SOUTHOLD,TOWN OF 360613 61405 MAIN ROAD DESIwNIED CBR9,YtFJS _ opal Z•NE VE 11-10-1W]oa,erede PrahRM Ala(OPA) ,rs lm ZLNEAE'S-tw B SOUTIIOLD,NY 11971 R INSURNOF NOT—E FOR STRUCTURESNE 1BUILTOR YIMPrAVEAB ROrE DONORa3TERER-ER _ b•,rR.•m,amawvn DE6IQJATED OPM WTHN THE CBRS .,e a�•. SUFFOLK COUNTY 6UB6TA1- PANEL 159 OF 1026 SITE TYPE: p-OOD IN NOT , ® MAP SUFFIX:H 150'4"CONCEALMENT POLE FLOOD MSUPMJ�NOT AVNLABIE FOR SrRUCNR6 NEWLY BULLT OR ® .ffbPln AFpRDaPx4 Ad SUB STANT1 D m INPRo.E00N OR AFTER rtBRWRY]d,tWT IN DEI(adATEO CBRS MFJS. Bmndarbad Ma Jdm N.O,abe CnYaIBa,ISRaeuma Lym 'CBrsl Mown onmb FllM waro Varebrtwlrrem tla driblet 0R5 F � uve tux r�.o•mvPw - rtTd Mbama artl d.pbWon tllls FlRMfor ONE '- .. idm—I dai W I purpota only TIY olfiaa CBRS maga an Ma[Iad by V Cm�ma rY Ma Wahl B,Mr Rawmwa.DIA as amm44 ad ,� i COIRRIGHE p Y']],AZBIITIH ENGL'EERL' I.:..�_ MAP NUMBER wcyrTs riEEavED mai road by IM US.FiN and wddEM1 Benita(FWS).Tra aRaa a d� TN¢Ra,aZD FOR Ah x Ilrv.lATIOi mrtARap xETor a 36103C0159H TNq.]ID FOR ort AOR n TME P.T F°R Ylol TME teas rml+s used m dvtwmina wMllrr d red M area a bcam xdidn s pat rA5 COKTRACTFD E 1O allot IT X mIREp.11.6 Me CBRS an avalladeid downbad al Mrd:i7wwwhaa,pdy.Fora - - -- - - JOINS PANEL 0+67 '20'm'E ��^ [ dUYIIp WY IgTa GPrD.RO1SA pI5ao4D. > pRbbleaerminednn prwbefherw rel.n aeabldaee wanln tla • ,.<, L "o-E ® tla01PNTETNE mJEp RITTER DI WIPz'H CBRS, rbr�y duatbna rgaMlrrpfM CBR.,PlaaeoomacsM.FWS _-,,,, - MAP REVISED TXQIT ME WIESEERRNI1R COriO1f0ALYUM + d Haan earn. ,,.ma.I(63gns.h°1 SEPTEMBER 25,2009 N Z Frdrnl Eaerg-)31...gh.W Agedcy SHEET TITHE t r __----- - - 2007 FLOOD INSURANCE p=rEUEo INAL AP �"'�MAP SH NUUOER: GIUPHIC SCALE -I/4 22 $ s m 1 2007 FLOOD INSURANCE RATE MAP B Z-18 AUG 0 9 zuD OECISION 783 � $3°1 Zoning Board of Appeals DATED i Xq-tV ,y COUNTY OF SUFFOLK C476zl n6-r STEVEN BELLONE SUFFOLK COUNTY EXECUTIVE DEPARTMENT OF ECONOMIC DEVELOPMENT AND PLANNING r� SARAH LANSDALE f CHRISTOPHER GONZALEZ COMMISSIONER ELISA PICCA CHIEF DEPUTY COMMISSIONER DEPUTY COMMISSIONER ��123 August 21, 2023 Town of Southold Zoning Board of Appeals 53095 Main Road P.O. Box 1179 Southold,NY 11971-0959 Attn: Leslie Weisman Dear Ms. Weisman: Pursuant to the requirements of Sections A 14-14 thru A 14-25 of the Suffolk County Administrative Code, the following application submitted to the Suffolk County Planning Commission is to be a matter for local determination as there appears to be no significant county-wide or inter-community impacts. A decision of local determination should not be construed as either an approval or disapproval. Applicant Municipal He Number QJSG Properties, LLC #7827 Budd's Pond Marina Inc. #7839 Very truly yours, By Christine DeSalvo Theodore R. Klein, Principal Planner TRK/cd Division of Planning & Environment H.LEE DENNISON BLDG ■ 100 VETERANS MEMORIAL HWY,11th FI ■ P.O.BOX 6100 ■ HAUPPAUGE,NY 11788-0099 ■ (631)853-5191 1 - y LEGEND SA!NARY MANHOLE DMNAGE UANHOLE ' WATER MAHOLE 0 CA5 MANNGLE O ELECTRIC MANHOLE o TELEPHGNE MANHOLE RECE ED 0 UMNCAN 4ANHOLE © FIRE DEPT.MANHOLE AU ® 223 a G WATER VVALVE ALVE FIRET • SIA.PRE RE DEDEPT,CONN, ( �`= =_Z-.-7°- s T crca TRAFFIC SIOA CONTROL BOK of Appeals 4� --_ -`7S = ELECTRIC SOX Zonin Boar _ = �©- R =\ STEEL UTILITY POLE w/UIE&HIGH TENSION x rs g �� tINr WOOD UTILITY POLE _'-yam._' ��� ___M1-a ____�_.,� -_` iyyr�• �A`f• WOOD UUUtt POLE WiiN UGHf �. _ -'_meg-''I _ t.� <"f= �- GUY PARE A rr45; N5 _59'47"'=3 - ^_ 5Li2 f1��__ ~t =- -- - -_'__ -_`y� ®MM Q DRAINAGE+NLETS _ 89 A'.- �. .'7 B_.-....1 _ ■ YARD WN ------ r '= _. mss_,.=-`-� 8-.�,.`3 (�0 CbR INLET PROPERTY UNE SUBJECT TAX LOT UNE FILED MAP LOT UNE YD GZ;VEL 472 FLED MAP LOT nY1MBER N --�•``- �!'ST. POST .- iJ.5 1"� ZI.P, !PON PIPE 1 OF MON, vCNUMENT FOUND n OREBAR nEfiAA fCUt10 co 6Ti TRAFFIC SIGN SGV z �45g3�7' SENER/DTLUNACE UNE N= ? t_6 I I ELECTRIC UNE OVERHEAD(UNLESS OIHER WISE NOTED,.EUR.ELEC,) E5 _ -----.CAS UNE. — 'NAEER UNE .c— v A / 4 ln'e.—(CALIPER) 9 C _ DEPRESSED CURB � I I CURB LINES r T C.C.(CCNC.CURB) C,C,G(INTEGRAL CCNC.CURB&GUTTER)) GaaVE7. x STN.C.'.STO`IE CUR9j F STORY Sit+.C (§LUE STO'-E CURB B.$C.UR 3.9.a"GlUM BLK-CUP B) G!f 7 T, _. 17 ev v� _ J $X Z+ rv—r'A.C.{ASPH.CURB) "Z PAINTED LINES o Sat(SOUO wrE u+q (ROADWAY MARKINGS) z isreP Eat) _ a ii 40 I!S DENOTES SPOT ELEVATION L 0 30 60 90 3 1 4A ,E La - a w 4.)z T 5 4 OA ;0.7 ;� NOTES: -UTILTEES SHOWN ARE PER FIELD OBSERVATIONS,PARTIAL CDNC #'6^ ASP H MARKCUTS AND AVAILQLE RECORDS AND ARE NOT GUARANTEED. ELEVATIONS REFER NAVD88 DATUM COORDINATES REFER TO NAD83(LIZONE) m ..__.. ._......_.... _.__ _.__..._.—............._....._. ........:sL ._.._ ... -_ S47'27'17"W DENOTES BEARINC<NAD83 �,.._._......._TS, 7r; 'J CA Tf150 ` S47'26'27"W - 200.00E (55331 OD1N) DENOTES BEARING PER DEED SYSTEM (S58'vww) ,t MAIN ROAD (N.Y.S. RTE. 25) SURVEY OF PROPERTY 61405 MAIN ROAD SITUATE AT SOUTHOLD TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK SCALE 1"=30' OCTOBER 23, 2018, �-. AMEWENGINEERfNG EYING P.C. .-. country road-Ste.6,nY UJ ZF' •!.- '�`l vfew11803 f.;' g 1 art AA :���•%�� " 1:516.454.7500 ^' URWMOWED AL1E!AWN OR ADORON TO A SURVEY MAP r f:' .afi• 516.8222743 JOB N0. 12610 � --" :K _ ndsurveying.rnm BARING A LaNSEO IANO SUMOOR`S SEAL IS A 1tOWION OF REWSIONS: 10/24/18 SECTION 7209,%GDMSION 2.Of TK NEW YORK STATE , EDUCATION IAL'. m zoTe 3e r { R:/12610/12610-MNN-RD-SOUTHOLD.DWG S.C.T.M.DIST. 1000 SEC.56 BLK.3 LOT 15 Ea Re. LS.,(L.S. N0. 49664) OFFICE LOCATION: *qf SU(/r�0 MAILING ADDRESS: Town Hall Annex �� l0 P.O. Box 1179 54375 State Route 25 l Southold,NY 11971 (cor.Main Rd. &Youngs Ave.) N Southold,NY 11971 Q Telephone: 631765-1938 a CoUnpM,� LOCAL WATERFRONT REVITALIZATION PROGRAM TOWN OF SOUTHOLD MEMORANDUM1189P4ON�NGeOARO �� �qc 'OF To: Donald Wilcenski,Chair �pNl C 19 223 Town of Southold Planning Board Q � ONAP From: Mark Terry,LWRP Coordinator ($ Date: November 20,2023 Re: Cell Tower at Albertsons Marine SCTM# 1000-56-3-15 Zoning District—M-II The Proposed Action involves the installation of a wireless communications facility 1501-foot above grade level (agl)concealment pole with the antennas of multiple wireless service carriers concealed within, and two Southold Fire District whip antennas mounted atop the concealment pole reaching a top height of 164-feet-101-inches agl, at 61405 Main Road in the hamlet of Southold, Town of Southold, Suffolk County,New York. Six Verizon Wireless panel antennas would be installed within the concealment pole in three sectors(two panel antennas per sector)at centerline heights of 141-feet-21 inches agl and 146-feet-11 inch agl.Three Dish Wireless panel antennas would be installed within the concealment pole in three sectors(one panel antenna per sector)at a centerline height of 1321feet agl. There would be room for additional future wireless service carrier antennas within the concealment pole below the Verizon Wireless and Dish Wireless in the General Business Zoning District. The Verizon Wireless equipment would be installed atop a proposed l 0f-f6ot-by-201-f6ot(2001-sf) steel platform surrounded by a 42f-inch-high handrail,and would be covered by a steel canopy with a top height of 11-feet-6f inches agl.Four Verizon Wireless GPS units would be mounted atop the equipment canopy to a top height of 13-feet-61 inches agl. The Dish Wireless equipment would be installed atop a proposed 81-foot-by-101-foot(801-sf)steel platform surrounded by a 42f-inch-high handrail. One Dish Wireless GPS unit would be mounted atop the equipment platform. The Southold Fire District equipment would be installed atop a proposed 81-foot-by-101-f6ot(80f-sf) equipment platform. The proposed action has been reviewed to Chapter 268, Waterfront Consistency Review of the Town of Southold Town Code and the Local Waterfront Revitalization Program(LWRP)Policy Standards. Based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, the proposed action is consistent with the below listed policies and therefore is recommended as 0 CONSISTENT with the LWRP. Policy 1. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and minimizes adverse effects of development. Policy 3. Enhance visual quality and protect scenic resources throughout the Town of Southold 3.1 Enhance visual quality and protect scenic resources throughout the Town of Southold A Use appropriate siting, scales,forms, and materials to ensure that structures are compatible with and add interest to existing scenic components. The parcel is zoned M-II which is defined as §280-54 Purpose. The purpose of the Marine II (AHI)District is to provide a waterfront location for a wide range of water-dependent and water- related uses, which are those uses that require or benefit from direct access to or location in marine or tidal waters and which, in general, are located on major waterways, open bayfronts or the Long Island Sound. Surrounding zoning includes: 1. North: R-80 zoning district,LIRR tracks,Town Open Space including wetlands 2. South: M11 zoning district,County Open Space including wetlands, small vacant parcel,active marina,R-40 zoning district to SE of parcel 3. East: M11 zoning district,exterior boat storage 4. West: M1I zoning district with Albertson Marine maintenance and sales office building, exterior boat storage.Residential(R-80 zoning)begins just west of the Albertson Marine parcel. It should be noted that this location is not optimum for the siting of the wireless communication facility and is the fifth of six preferred locations outlined in the Town Code. The co-location of the Southold Fire District communication antennae is the main reason the wireless communication facility has been considered for this location. Communication service gaps outlined in the submitted reports, along with public hearing testimony regarding the emergency response communication challenges Southold's Fire District face,this location is well suited to improve telecommunications services in this area. Based on the Applicant's submitted materials, the Towns consultant(CityScape)concurs with the Applicant's findings that the proposed antennas for Dish,Verizon,and the Fire District will need to be placed on a new tower, on non- Town-owned property, in this zoning district due to a lack of opportunity elsewhere(Planning Board Staff Report November 20,2023). The monopole will be directly visible from State Route 25 (S.R. 25), a New York State Scenic Byway,and is visible from publicly accessible vantage points seasonally and year-round by routine travel;of residents and visitors. The equipment compound is located behind an existing boat storage warehouse structure on the subject property, is set back from the road, and is not expected to be readily apparent to people traveling on NYS 25 due to the existing boatyard use. A visual analysis titled Proposed Wireless Communications Facility Albertsons Marine(June 2023), prepared by VHB Consultants has been submitted and reviewed. The study analyzed a one-mile radius from the 150' proposed concealment pole and associated equipment using a crane test. The 12+foot Fire Department antenna proposed on the concealment pole was included.It is recognized that the concealed antennae design contributes to mitigating adverse impacts on scenic character. Furthermore, both carriers have submitted evidence supporting their proposed antenna heights of 146 and 141 feet AGL for Verizon and 132 feet for Dish. The Fire District also provided an engineering report from Integrated Wireless Technologies(IWT)which states that 150 [feet of antenna height] is required to provide coverage at levels acceptable for Public Safety communications systems and ensure the ability for the firefighter to communicate during critical calls." Based upon the analysis,the proposed action is consistent with this policy. Specific mitigation designs have been considered: 1. Concealment pole design. All antennae, excluding the whip antennas at the top of the pole, will be concealed. 2. Paint the pole with a neutral color to blend in with the sky. The applicant is proposing a blue/gray color. 3. Screened by existing development,a six-foot tall chain link fence,and evergreen vegetation. The applicant is proposing a staggered pattern of 6' tall evergreen trees along the northern and western perimeter of the equipment compound. The following notable designs of the wireless communications facility design to lessen impacts on policies were also considered: 1. Design to minimize impacts from flooding. According to New York State, a 12- inch scenario sea level rise will affect the parcel. The compound should be designed accordingly. 2. Design to minimize impacts to the health and safety of the population from FCC Maximum Permissible Exposure(MPE)limits. "Antenna Site FCC RF Compliance Assessment and Report by Pinnacle Telecom Group, dated August 22,2022." 3. Structural integrity design to minimize impacts from a tower failure. Structural Report Letter from Carpenter&Cross, Structural Engineers, dated September 22, 2023. The site is cleared and improved;therefore,the proposed action will not result in the significant removal or destruction of large quantities of vegetation.No significant adverse impacts to soils will result. Pursuant to Chapter 268, the Board shall consider this recommendation in preparing its written determination regarding the consistency of the proposed action. Cc: Southold Town Zoning Board of Appeals Mara Cerezo,Planner MAILING ADDRESS: PLANNING BOARD MEMBERS fav S.OUpy P.O.Box 1179 DONALD J.WILCENSKIr �� Southold,NY 11971 Chair h OFFICE LOCATION: JAMES H.RICH III CA, Town Hall Annex MARTIN SIDOR t�j ,gyp { 54375 State Route 25 PIERCE RAFFERTY (cor.Main Rd. &Youngs Ave.) AMELIA JEALOUS-DANK Ca Southold,NY Telephone:631 765-1938 www.southoldtownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD December 19, 2023 V � �D Mr. Gregory R. Alvarez ,SEC 212023 Amato Law Group PLLC 666 Old Country Road, Suite 901 8®ARD®FppP�A1� Garden City, NY 11530 ®N1NG Re: SEQRA Determination Cell Tower at Albertson Marine Located at 61405 Main Road, Southold SCTM#1000-56-3-15 Zoning District: Mll Dear Mr. Alvarez,. The following resolutions were adopted at a meeting of the Southold Town Planning Board on Monday, December 18, 2023: WHEREAS, this proposed wireless facility site plan is for a ±150' above grade level (a.g.l.) concealment pole, including antennas, cables, and related equipment for two wireless carriers (Verizon and DISH) and Southold Fire District's emergency communications, along with a ±2,450 sq. ft. equipment compound on a ±0.95-acre parcel with a ±10,800 sq. ft. existing boat storage warehouse, in the Marine II Zoning District, Southold; and WHEREAS, the applicant submitted an application for Site Plan review on August 9, 2023; and WHEREAS, on October 16, 2023, the Planning Board accepted the application for review; and WHEREAS, on October 16, 2023, the Southold Town Planning Board, pursuant to State Environmental Quality Review Act (SEQRA) 6 NYCRR, Part 617, determined that the proposed action is an Unlisted Action as it does not meet any of the thresholds of a Type I Action, nor does it meet any of the criteria on the Type II list of actions; and �;a Cell Tower at Albertson Marine Page 2 December 19, 2023 WHEREAS, on October 16, 2023, the Southold Town Planning Board, pursuant to the State Environmental Quality Review Act §617.6, established itself as Lead Agency for this Unlisted Action; and I /) k WHEREAS, on October 16, 2023, the Southold Town Planning Board, pursuant to §617.6 of the Environmental Conservation Law acting under the State Environmental Quality Review Act, initiated the SEQR lead agency coordination process for this Unlisted Action; be it therefore RESOLVED, that the Southold Town Planning Board, as Lead Agency pursuant to SEQRA, hereby makes a determination of non-significance for the proposed action and grants a Negative Declaration. Enclosed is a copy of the Negative Declaration for your records. If you have any questions regarding the information contained in this resolution, please contact the Planning Board Office. Respe ully, ,0 Donald J. Wilcenski Chairman Encls. AIAIL._TNG ADDRESS: PLANNING BOARD MEMBERS 8 011 P.O. Box 1179 DONALD J.WILCENSKI �y� �{ Southold,NY 11971 Chair Y �` OFFICE LOCATION: JAMES H.RICH III en Town Hall Annex MARTIN SIDOR �O i 54375 State Route 25 PIERCE RAFFERTY Oo > (cor. Main Rd. &Youngs Ave.) AMELIA JEALOUS-DANK C� `(,� Southold, NY Telephone: 631765-1938 www.southoldtow-xmy.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD State Environmental Quality Review NEGATIVE DECLARATION December 18,2023 Name of Action: Cell Tower at Albertson Marine SCTM#: 1000-56-3-15 Location: The property is located at 61405 Route 25,Greenport,NY SEQR Status: Type I ( ) Unlisted (X-) This notice is issued pursuant to Part 617 of the implementing regulations pertaining to Article 8(State Environmental Quality Review Act)of the Environmental.Conservation Law. The Town of Southold Planning Board as lead agency has determined that the proposed action described below may have a potentially significant adverse impact on the environment, but the.impact can be eliminated or adequately mitigated by conditions imposed by the lead agency,without the need for additional environmental studies. The following studies and reports were considered in making this determination: 1. October 16,2023 Staff Report prepared by Mara Cerezo,Planner(Subject File) 2. November 20,2023 Staff Report prepared by Mara Cerezo,Planner(Subject File) 3. Reports cited. Description of Action: The Proposed Action involves the installation of a wireless communications facilityl50f-foot above grade level (agl)concealment pole with the antennas of multiple wireless service carriers concealed within,and two Southold Fire District whip,antennas mounted atop the concealment pole reaching a top height of 164-feet-1 Of-inches agl, at 61405 Main Road in the hamlet of Southold,Town of Southold, Suffolk County,New York. Six Verizon Wireless panel antennas would be installed within the concealment pole in three sectors(two panel antennas per sector)at centerline heights of 141-feet-2t inches agl and 146-feet-1t inch agl.Three Dish Wireless panel antennas would be installed within the concealment pole in three sectors(one panel antenna per sector)at a centerline height of 132ffeet agl.There would be room for additional future wireless service carrier antennas within the concealment pole below the Verizon Wireless and Dish Wireless in the General Business Zoning District. The Verizon Wireless equipment would be installed atop proposed l Of-foot-by-20f-foot(200t-sf) P a steel platform surrounded by a 42t-inch-high handrail,and would be covered by a steel canopy with a top height of 11-feet-6f inches agl. Four Verizon Wireless GPS units would be mounted atop the equipment canopy to a top height of 13-feet-6t inches agl. The Dish Wireless equipment would be installed atop a proposed 8f-foot-by-10±-foot(80±-sf)steel platform surrounded by a 42=L-inch-high handrail. One Dish Wireless GPS unit would be mounted atop the equipment platform. The Southold Fire District equipment would be installed atop a proposed 8f-foot-by-10+-foot(801-so equipment platform. The equipment within the compound would be connected to the concealment pole via cable bridges(one cable bridge per equipment platform).Additionally,utility connections(i.e.,power and telco)would be routed underground from an existing utility pole on Main Road to a proposed transformer and mesa cabinet within the equipment compound.Power and telco conduits would be routed underground within the equipment compound from the transformer and mesa cabinet to the equipment platforms. All equipment within the compound would be elevated a minimum of 3t feet agl to provide a minimum of two feet of clearance above the base flood elevation of 6' (North American Vertical Datum of 1988 (Application Narrative 2023) 1. Impact on Land The proposed action is f 41,346 sq.ft.non-conforming parcel in the Marine II Zoning District and is improved with a f 10,800 sq. ft. boat storage warehouse([Note: Warehouse was built in 1971-72 with no prior site plan or Planning Board review)and paved and gravel areas with exterior boat storage. The M-II purpose is defined as to provide a waterfront location for a wide range of water-dependent and water-related uses,which are those uses that require or benefit from direct access to or location in marine or tidal waters and which,in general,are located on major waterways, open bayfronts or the Long Island Sound. Surrounding zoning includes: To the north is a LIRR easement with active train service and Residential-80(R-80)zoned Town Open Space parcels including wetlands. The parcels to the north and northwest of the LIRR easement are protected and no development upon the parcel can occur. To the south, east and west is Marine II zoning. The parcel to the south across S.R.25 is also protected. The proposal includes constructing a 2,450 sq. ft. fenced ground equipment area,with evergreen plantings on the north and west sides of the compound.Utility connections will be routed underground for an existing utility pole on Main Road. The current lot coverage is 26.2%and landscape coverage: 0%. The proposed lot coverage is 32%and landscape coverage is 4.43%: An improvement in landscaping. The action requires a Special Exception from the Southold Town Planning Board. It should be noted that this location is not optimum for the siting of the wireless communication facility and is the fifth of six preferred locations outlined in the Town Code. The co-location of the Southold Fire District communication antennae is the main reason the wireless communication facility has been considered for this location. Communication service gaps outlined in the submitted reports, along with public hearing 2 testimony regarding the emergency response communication challenges Southold's Fire District face,this location is well suited to improve telecommunications services in this area. Based on the Applicant's submitted materials,the Towns consultant(CityScape)concurs with the Applicant's findings that the proposed antennas for Dish,Verizon, and the Fire District will need to be placed on a new tower,on non- Town-owned property, in this zoning district due to a lack of opportunity elsewhere(Planning Board Staff Report November 20,2023). Based on the existing use and improvements,the proposed action will not cause a substantial intensification of use in the area relative to existing,surrounding development. Moderate to large adverse impacts on land are not expected to occur. 2. Impact on Geological Features Adverse impacts to Geologic Features will not occur. 3. Impacts on Surface Water There are no freshwater or marine wetlands on the parcel. Tidal wetlands do occur the north of the parcel,separated by a LIRR track. Adverse impacts to surface water are not expected. Storm water will be controlled on-site. 4. Impacts on Groundwater No new water service is proposed nor will chemicals be applied as a result of this action.Adverse impacts to groundwater are not expected. 5. Impact on/from Flooding The location is not optimal and will be affected by floods. The proposed action is located within a FEMA flood zone AE E16' and is designed to tolerate flooding by locating the base floor elevation 3' above the expected flood elevation of 6'. Future adaptation to floods may be necessary over time. 3 I& FEMA's National Flood Hazard Layer(NFHL)Viewer "JJ Its # c WSlI , t sn� A 12-inch scenario sea levet rise will affect the parcel, according to New York State projection mapping. The compound should be designed accordingly. Services News Government ► 0 +1 i I sea Lioel rive(in)0 12 _ I 2 Fi•cu#ence Interval tM U .10 3(bnynyyn 8 �UuihcAd,SUfFtkk Z.U;lhtj Q •ItR r rtw.ti CnesW v'ir.Ra//w��': kYdV 1'1a�by 16-i; .'J•+n fciRa.ra:.len 1r „� Lt,FkYya Nelnd.et+•rginy I:vrr,��'t W:.n rvJ.n rnsxc.\ !9. JJrr.-9NfP'<fn4}Q >n;Mr ll-vt)SF•, .r.....:v++C eF.•..+r.x.wtGn trot �14 y•w 6:r•✓ ,. F .. 'N.'7 r#a• , f i1 1111 y O Inc—*#in Caval FI•dpl Jln for Sou"W,$u Rdk Ceunly • Adverse impacts(inundation)to the ground compound from flooding are expected during storm events and over time due to sea level rise. Initial design and flood adaptive strategies should be incorporated in the design. Low impacts on the structure are expected in consideration of the mitigation for flooding provided. 6. Impact on Air No adverse impacts to air quality would occur as a result of the action. 7. Impact on Plants and Animals Recommended Best Practices for Communication Tower Design,Siting, Construction,Operation, Maintenance,and Decommissioning Migratory Bird Program U. S.Fish and Wildlife Service Falls Church,Virginia(March 2021)was consulted and the following is recommended to lessen impacts to birds in the vicinity of the tower in design. 1. New towers should be not more than 199 ft. above ground level(AGL).This height increases the mean free airspace between the top of the tower and average bird flight height,even in weather conditions with reduced cloud ceiling; 2. Recommend using monopole structures. 3. Lights are a primary source of bird aggregation around towers,thus minimizing all light is recommended. 4. Security lighting for on-ground facilities, equipment,and infrastructure should be motion-or - heat-sensitive, down-shielded,and of a minimum intensity to reduce nighttime bird attraction and eliminate constant nighttime illumination while still allowing safe nighttime access to the site. The site is cleared and improved;therefore,the proposed action will not result in the significant removal or destruction of large quantities of vegetation.No significant adverse impacts to soils will result. The New York Department of Environmental Conversation(NYSDEC)Environmental Resource Mapper indicates that rare and protected species are located within the vicinity where the project is proposed. However,due to the previous development, impacts to protected species are expected to be low including impacts on The Northern Long-eared Bat and Osprey. Northern Long-eared Bat Scientific Name:Myotis septentrionalis New York Status: Endangered* Federal Status: Endangered* On November 29, 2022,the United States Fish and Wildlife Service(USFWS)published a ruling reclassifying Northern Long-eared Bat from Threatened to Endangered under the federal Endangered Species Act.This rule is effective March 31,2023.The change to Endangered in New York will take place at the same time as the Federal listing. The NYSDEC concurs with the conclusion of the USFWS that the northern long-eared bat(NLEB) population decline is not the result of habitat loss but rather individual tree loss. No trees will be impacted as a result of this proposal. 5 The Osprey is-a bird of with a New York Status of Special Concern. Ospreys seek,tall structure to build nests, and this location provides an optimal location for habits. It is recommended that an Osprey deterrents be added to the top of the pole. If birds are nesting on communication towers that require maintenance activities,contact the state natural resource protection agency and/or the USFWS for permits,recommendations, and requirements. Schedule construction and maintenance activities around the nesting and activity schedule of protected birds. Regulated wetlands do not occur on site but are located north and south of the parcel. No physical disturbance capable of adversely impacting the wetlands is proposed. No significant impacts to a significant habitat area will occur. 8. Impact on Agricultural Resources The proposed action will not cause significant adverse impacts to agricultural resources. 9. Impact on Aesthetic Resources A visual analysis titled Proposed Wireless Communications Facility Albertsons Marine(June 2023), prepared by VHB Consultants has been submitted and reviewed.The study analyzed a one-mile radius from the 150' proposed concealment pole and associated equipment using a crane test. The 12+foot Fire Department antenna proposed on the concealment pole was included in the test.It is recognized that the concealed antennae design contributes to mitigating adverse impacts on scenic character. The monopole is visible from State Route 25 (S.R. 25),a New York State Scenic Byway, and is visible from publicly accessible vantage points seasonally and year-round by routine travel of residents and visitors.The placement of the equipment compound located behind an existing boat storage warehouse structure on the subject property, is set back from the road,and is not readily apparent to travelers on S.R. 25.The location mitigates the scale of the pole by co-locating with the existing structures on site. 1. North: R-80 zoning district,LIRR tracks,Town Open Space including wetlands 2. South: M11 zoning district, County Open Space including wetlands,small vacant parcel, active marina, R-40 zoning district to SE of parcel 3. East: MII zoning district,exterior boat storage 4. West: MH zoning district with Albertson Marine maintenance and sales office building, exterior boat storage.Residential(R-80 zoning)begins just west of the Albertson Marine parcel. The location of the concealment pole(tower)has been assessed for optimal coverage and range for emergency communications. Although the tower is expected to be visible from NYS Route 25,the location of the tower on a developed parcel positioned behind a large building with boat storage is not obtrusive. Impacts on scenic character and aesthetics are expected to be low. 10. Impact on Historic and Archeological Resources The applicant submitted correspondence from SHPO dated November 16,2017 concluding that no properties would be subject to potential affects and that no adverse impacts would occur to historic properties. No cultural or historic resources have been identified within 300' of the site.The site is improved;therefore,the action would not result in adverse impacts to cultural/historic resources. Similarly,the proposed action will not impair the character or quality of important historic,architectural resources. 6 11. Impact on Open Space and Recreation The parcel is located south of Southold Town-owned open space that is separated by an LIRR elevated track and north of a Suffolk County-owned open space parcel. There is no connection to the open space from the parcel. Adverse impacts to open space and recreation are not expected to occur due to this action. A8�12. Impact on Critical Environmental Areas The parcel is located within the NYSDEC Critical Environmental Area Peconic Bay and Environs.Due to the proposed use and scale of development,impacts to groundwater/surface waters will not result,and therefore,adverse impacts to the Critical Environmental Area will not occur as a result of this action. Protected wildlife species in the area will be considered in design to deter interaction with the monopole. 13. Impact on Transportation The Federal Aviation Administration has issued a Determination of No Hazard to Air Navigation letter on December 12,2022. No marking lighting will be required unless one is installed voluntarily. Adverse impacts from vehicle trips are expected to be low,will be short-term and limited to construction and maintenance vehicles.No adverse impacts to transportation will occur as a result of the action. 14. Impact on Energy No-to-low adverse impacts on energy use will occur as a result of the action. The tower will be connected to the existing electric service lines along NYS Route 25. 15. Impact on Noise,Odor, and Light Noise impacts from the c6nstruction of the tower are expected to occur in short duration. No odors will be produced and lighting will be minimal. Adverse impacts from noise,odor and light are expected to be none-to-low as a result of the action. 16. Impact on Human Health The proposed location of the tower does not meet Town Code requirements that require a minimum distance to adjacent residential property lines of no less than 500 feet. Human health threats from wireless technology have been linked to the level Radio Frequency(RF). Accordingly,the FCC Maximum Permissible Exposure(MPE) limits of up to 100 percent MPE are considered acceptable and safe(Pinnacle Telecom Group). Due to the size of the parcel,the opportunity to increase the distance from residential-zoned property lines is not achievable. DISH The applicant has submitted an assessment of Radio Frequency(RF)Compliance entitled RF Justification Report Site ATYNYCO2239A 7 VERIZON Verizon Wireless is proposing the following: a. Six(6)panel antennas(the"Antennas")concealed within a proposed 15 0'-0"concealment pole(to be constructed.by Elite),with Antenna centerline heights of+/- 146'-1"and 141'- 2"AGL; b. An equipment platform upon which equipment cabinets and associated equipment,with canopy above,will be located,within the proposed compound(to be constructed by Elite); c. Four(4)GPS units mounted on the proposed equipment canopy;and d. All other appurtenances, devices,cables,conduits and wires related thereto. As shown in the Height Analysis,reducing the height of the concealment pole to 110 feet AGL, or even to 130 feet AGL,would result in significant coverage losses compared to the proposed height of 150 feet AGL. Constructing the tower as a concealment pole instead of a standard monopole to reduce visual impact of the communications facility already significantly reduces the flexibility of wireless operators by restricting the size of antennas that can be deployed and the azimuths at which they can be oriented. Any reduction in the height would further compound the impact of this limitation. MPE LIMIT According to the FCC Maximum Permissible Exposure(MPE)limit has been constructed in such a manner that continuous human exposure to RIF emissions up to and including 100 percent of the MPE limit is acceptable and safe(Pinnacle Telecom Group). The maximum calculated RF level from the proposed antenna operations at the site is 1.4796 percent of the FCC MPE limit more than 65 times below the limit established as safe for continuous human exposure to the RF emissions from antennas. The antennas comply with the FCC MPE limits. The distance of the concealment pole to the Long Island Rail Road(L.I.R.R.)Easement and active tracks could result in adverse impacts to the public health and safety of train passengers from structural failure. On September 26,2023,the applicant submitted a structural assessment of the tower and the fall zone. The report concludes that a structural failure of the monopole is unlikely,and it could be designed to fail at the 78' elevation,thereby reducing the probability of a full collapse. This design would provide a theoretical failure radius of 72' for the 150' AGL slimline pole(Carpenter&Cross Structural Engineers(2023)). Moderate to large impacts on human health are not expected. 17. Consistency with Community Plans The siting of telecommunication towers throughout the Town is determined on a case-by-case basis and needs analysis under Planning Board review.Process and Town objectives to protect the quality of life and aesthetic qualities,among others,are incorporated in Chapter 280.Zoning Article XVII. Wireless Communication Facilities of the Southold Town Code. The purpose of the section is stated as follows: §280-67 Purpose. 8 It is the express purpose of this article to minimize the visual and environmental impacts of wireless communication facilities while protecting the health, safety and welfare of Southold's citizens and allowing wireless service providers to meet their technological and service objectives. In addition, the regulation of wireless facilities, including the type of structure, is intended to protect the scenic and aesthetic qualities of the Town of Southold. This article allows wireless communication facilities in certain preferred locations to be reviewed and approved in keeping with the Town's existing zoning and historic development patterns, including the size and spacing of structures. The proposed 80' height limitation within the Town Code protects the scenic and aesthetic qualities of the Town with the understanding that to achieve adequate telecommunication coverage town-wide, additional towers will be needed in preferred locations to resolve coverage gaps and provide additional locations for carriers.The inclusion of emergency communications to resolve gaps is a priority within the Town. Telecommunications equipment was specifically mentioned.I Article XVII. Wireless Communication Facilities of the Southold Town Code was subsequently updated to include greater protection of the scenic qualities and health safety and welfare of the Town residents and visitors. A visual analysis titled Proposed Wireless Communications Facility Albertsons Marine(June 2023), prepared by VHB Consultants has been submitted and reviewed: The study analyzed a one-mile radius from the 150' proposed concealment pole and associated equipment using a crane test. The 12+foot Fire Department antenna proposed on the concealment pole was included.It is recognized that the concealed antennae design contributes to mitigating adverse impacts on scenic character. Furthermore, both carriers have submitted evidence supporting their proposed antenna heights of 146 and 141 feet AGL for Verizon and 132 feet for Dish. The Fire District also provided an engineering report from Integrated Wireless Technologies(IWT)which states that"150 [feet of antenna height] is required to provide coverage at levels acceptable for Public Safety communications systems and ensure the ability for the firefighter to communicate during critical calls." Based upon the analysis,the proposed action is consistent with this policy. Specific mitigation designs have been considered: 1. Concealment pole design. All antennae, excluding the whip antennas at the top of the pole,will be concealed. 2. Paint the pole with a neutral color to blend in with the sky. The applicant is proposing a blue/gray color. 3. Screened by existing development, a six-foot tall chain link fence,and evergreen vegetation. The applicant is proposing a staggered pattern of 6' tall evergreen trees along the northern and western perimeter of the equipment compound. The storage of large vessels on the property, including sailboats with masts, is not in contrast with the current surrounding land use pattern(s)or the proposed tower. The following notable designs of the wireless communications facility design to lessen impacts on policies were also considered: 1. Design to minimize impacts from flooding. According to New York State,a 12- inch scenario sea level rise will affect the parcel. The compound should be designed accordingly. 9 2. Design to minimize impacts to the health and safety of the population from FCC Maximum Permissible Exposure(MPE) limits. "Antenna Site FCC RF Compliance Assessment and Report by Pinnacle Telecom Group, dated August 22,2022." 3. Structural integrity design to minimize impacts from a tower failure(Structural Report Letter from Carpenter&Cross, Structural Engineers,dated September 22, 2023). The site is cleared and improved;therefore,the proposed action will not result in the significant removal or destruction of large quantities of vegetation.No significant adverse impacts to soils will result. As proposed the action is recommended as Consistent with the Town of Southold Local Waterfront Revitalization Program with community plans. 18. Consistency with Community Character The wireless communication facilities and proposed 150' height of the monopole requires numerous approvals and waivers outlined below(Planning Board Staff Report). 1. Planning Board: L Site Plan ii. Special Exception §280-142:the Planning Board shall be empowered to issue a special exception approval for wireless communication facilities, subject to the provisions of this chapter; see Special Exception Standards and Matters to be Considered. 2. Zoning Board of Appeals: i. The proposed wireless facility use constitutes a second principal use on this 41,346 sq.ft. lot in the M1I zone district, where 80,000 sq.ft.per use is required. ii. The proposed wireless facility has a rear yard setback of 8',where 25' is required. iii. The proposed wireless facility has lot coverage of 32%,where<_30% is required. 3. Southold Town Board of Trustees: L The proposed facility is within 100' of wetlands. B. Southold Town Code 4280-70• General Requirements for all wireless communication facilities. 1. §280-70(D)Location of wireless facilities: (1)Applicants for wireless communications facilities shall locate, site and erect said wireless facilities in accordance with the following priorities: (a) On an existing antenna support structure or other structures on Town-owned properties, including the right-of-way. (b) On an existing antenna support structure or other structures on other property in the Town. 10 A (c)A new antenna support structure on Town-owned properties. (d)A new antenna support structure on properties in the LI or LIO Zoning Districts. (e)A new antenna support structure on properties in the ka MI, B or HB Zoning Districts. Staff: This proposal is on a property zoned M1I,which is a low priority location.Applicant has submitted documentation stating that properties with a higher priority were not feasible for the Board's review and were evaluated"based upon a need to remedy service deficiencies in a specific geographic area". See Appendix C:Alternative Sites Affidavit. 2. §280-70(F)Antenna support structures shall not be located in the following areas without a permit from all jurisdictional agencies: (1) Wetlands, tidal and freshwater Staff: The proposed facility is located within the limits of the NYSDEC's and Town of Southold's freshwater wetlands regulatory jurisdiction. An application is before the Southold , Town Board of Trustees.Approval will be required from NYSDEC prior to construction. 3. §280-70(G)Fall Zone An antenna support structure must include an area surrounding it that is free of other structures and areas where people congregate, except the base equipment, with the radius equal to a distance of two times the height of the structure.A smaller fall zone may be allowed if supported by a report submitted by a qualified structural engineer. The structural engineer's report shall be submitted to and reviewed by the Planning Board and corroborated by an independent consultant hired by the Town that demonstrates a smaller fall zone is appropriate and safe. Staff: A required fall zone for a tower at the proposed height of 150' would need to be equal to 300',which is two times the height of the structure.The applicant is requesting relief and has submitted a Structural Report Letter from Carpenter&Cross, Structural Engineers,dated September 22,2023. 4. §280-70(M Federal aviation regulations. Staff: Appendix F includes an FAA Determination of No Hazard to Air Navigation Memo dated December 12, 2022. 5. §280-70(n Antenna support structures in the LI, LIO, Ml; MI, B, and HB Zoning Districts are subject to the following restrictions: (1)Ifinimum lot size: in accordance with the bulk schedule for each zone. Staff: The property is under the minimum lot size for the zone, and is a non-conforming parcel. The MII zoning district requires 80,000 sq.ft. per use.There is a minimum lot size of 160,000 sq. ft.to support the two uses(existing boat storage warehouse and proposed wireless facility), therefore a variance is required form the Town Zoning Board of Appeals. (2)Maximum height: 80 feet. 11 Staff: The applicant is requesting a waiver for this requirement as the proposed wireless facility includes a concealed monopole of 150', exceeding the maximum allowed height by 87.5%. See below section V. Southold Town§280-76.2: Waivers of criteria." 10 (3)Minimum distance of all wireless equipment to adjacent residential property lines or streets shall be no less than 500 feet. Staff: The nearest residential property line is located±8' from the northern property line, which coincides with a transition to the R-80 zoning district.The nearest residential structure is located over 500' away.Applicant is requesting a waiver,see below section V. Southold Town§280- 76.2: Waivers of criteria." 6. §280-70(K)Radio emissions mustfall within the maximum permissible exposure (MPE) limits established.by the FCC. Staff: Applicant submitted"Antenna Site FCC RF Compliance Assessment and Report',by Pinnacle telecom Group, dated August 22, 2022 in Appendix G. 7. §280-70(NI)No antenna support structure shall be constructed at, or remain at, a height that is taller than that required by installed and operational antennas. Staff: Applicant submitted Radio Frequency Reports for Verizon Wireless,Dish Wireless,and Southold Fire District in Appendix E. 8, §280-70(1)Site Design Standards (I) Setbacks. _ Marine II Zone Required Provided* Front yard 35' 154' Side yard(East) 25' 47' Side yard(West) (50'combined) 80' Rear yard 25' 8'(variance required) *Distance to fenced compound. (2) Signs. Signs shall not be permitted on facilities except for signs displaying contact information and safety instructions, which are required. Such signs shall not exceed five square feet in surface area. Staff:No signage is proposed. Applicant states that required contact and safety information will comply with Town Code. (3) Base station equipment shelter. Staff: The proposed site plan includes a±2,450 sq. ft. fenced ground-based equipment compound. As noted above,the rear yard does not comply with the required rear yard setback and requires a variance from the ZBA. 12 (4) Base equipment landscaping. Staff: The applicant is proposing a staggered pattern of 6' tall evergreen trees along the northern and western perimeter of the equipment compound as shown on Sheets Z-08 (Verizon)and A-1C (Dish).The position of the equipment compound behind the existing building limits its visibility from surrounding areas.Infrequent views of the compound may be seen by LIRR passengers. Plantings are planned for the northern perimeter adjacent to the LIRR tracks to aid with screening of base equipment.However,the plant species and height are shown only on Sheet Z-08(Verizon Wireless)of the Compound Plan. The applicant shows Emerald Green Arborvitae at a minimum height of 6'.Due to the elevated nature of the ground equipment a taller screening tree and fencing may be considered. (S) Site lighting. The lighting permitted shall be the minimum required to protect the public welfare. Facilities sited on existing developed sites shall be incorporated into the lighting plans of those sites. Outside lighting shall usefully shielded fixtures so that the light source is not visible from beyond the property line, and no light is reflected or shone towards the sky, except in the case of structures required to follow FAA guidelines for safety lighting. Staff: The applicant details a plan for work lights to be used by maintenance personnel on the Equipment Plan(Sheet Z-09),Construction Details-1 (Sheet Z-12),Equipment Platform and H- Frame Details(Sheet A-3),and Equipment Details— 1 (Sheet A-4). Cut sheets have not been provided. Since this parcel has not been through the site plan process before,there is no lighting plan on file for the existing developed site location. Although the 150' height of the concealment pole is not fully consistent with community character,the mitigation in design provided and the need for emergency communication services at the height proposed and in this location are expected to result in low impacts to the area. Based upon the above,no significant adverse impacts to the environment are expected to occur should the project be implemented as planned. For Further Information: Contact Person: Mark Terry,Assistant Town Planning Director Address: Southold Town Planning Board Telephone Number: 631-765-1938 Cc: Southold Town Zoning Board of Appeals James Squicciarini,Assistant Town Attorney 13 Agency Use Only (HApplkablcl Project: to0456315 Date Full Environmental Assessment Form Part 3-Evaluation of the Magnitude and Importance of Project Impacts and Determination of Significance Part 3 provides the reasons in support of the determination of significance. The lead agency must complete Part 3 for every question in Part 2 where the impact has been identified as potentially moderate to large or where there is a need to explain why a particular element of the proposed action will not,or may,result in a significant adverse environmental impact. Based on the analysis in Part 3,the lead agency must decide whether to require an environmental impact statement to further assess the proposed action or whether available information is sufficient for the lead agency to conclude that the proposed action will not have a significant adverse environmental impact. By completing the certification on the next page,the lead agency can complete its determination of significance. Reasons Supporting This Determination: To complete this section: • Identify the impact based on the Part 2 responses and describe its magnitude. Magnitude considers factors such as severity, size or extent of an impact. • Assess the importance of the impact. Importance relates to the geographic scope,duration,probability of the impact occurring,number of people affected by the impact and any additional environmental consequences if the impact were to occur. • The assessment should take into consideration any design element or project changes. • Repeat this process for each Part 2 question where the impact has been identified as potentially moderate to large or where there is a need to explain why a particular element of the proposed action will not,or may,result in a significant adverse environmental impact. • Provide the reason(s)why the impact may,or will not,result in a significant adverse environmental impact • For Conditional Negative Declarations identify the specific condition(s)imposed that will modify the proposed action so that no significant adverse environmental impacts will result. • Attach additional sheets,as needed. See Negative Declaration narrative dated November 2023 attached. Determination of Significance-Type 1 and Unlisted Actions SEQR Status: 0✓ Type 1 ❑Unlisted Identify portions of EAF completed for this Project: Q✓ Part 1 ❑✓ Part 2 21 Part 3 Upon review of the information recorded on this EAF,as noted,plus this additional support information and considering both the magnitude and importance of each identified potential impact,it is the conclusion of the n� Southold Town Planning Board as lead agency that: r 1 ❑✓ A. This project will result in no significant adverse impacts on the environment,and,therefore,an environmental impact statement need not be prepared. Accordingly,this negative declaration is issued. ❑ B. Although this project could have a significant adverse impact on the environment,that impact will be avoided or substantially mitigated because of the following conditions which will/be required by the lead agency: There will,therefore,be no significant adverse impacts from the project as conditioned,and,therefore,this conditioned negative declaration is issued. A conditioned negative declaration may be used only for UNLISTED actions(see 6 NYCRR 617A). ❑ C. This Project may result in one or more significant adverse impacts on the environment,and an environmental impact statement must be prepared to further assess the impact(s)and possible mitigation and to explore alternatives to avoid or reduce those impacts. Accordingly,this positive declaration is issued. Name of Action: Cell Tower at Albertson Marine Name of Lead Agency: Southold Town Planning Board Name of Responsible Officer in Lead Agency: Donald J.Wilcenski,Chairman Title of Responsible Officer: Same Signature of Responsible Officer in Lead Agency: Date: December 19, 2023 Signature of Preparer(if different from Responsible Officer) Date: December 19,2023 For Further Information: Contact Person: Mark Terry,Assistant Director of Planning Address: P.O.Box 1179,53095 Main Road,Southold,NY 11971 Telephone Number:631-765-1938 E-mail:Mark.Terry@town.southold.ny.us For Type'l Actions and Conditioned Negative Declarations,a copy of this Notice is sent to: Chief Executive Officer of the political subdivision in which the action will be principally located(e.g.,Town/City/Village of) Other involved agencies(if any) Applicant(if any) Environmental Notice Bulletin: htt :/p /Nvww.dcc ny aov/enb/atb.html PRINT FULL FORM Page 2 of 2 RECEIVED FORM NO. 3 . AUG 0 9 20283 TOWN OF SOUTHOLD f I BUILDING DEPARTMENT Zoning Board of Appeals SOUTHOLD,N.Y. NOTICE OF DISAPPROVAL DATE: January 18, 2023 RENEWED: August 9,2023 TO: Gregory R. Alvarez (Budd's Pond Marina) 666 Old Country Road, Suite 901 Garden City,NY 11530 Please take notice that your application dated January 4, 2023: For permit:'to construct a new wireless telecommunications facility: Location of property: 61405 Main Road, Southold, NY County Tax Map No. 1000 - Section 56 Block 3 Lot 15 Is returned herewith and disapproved on the following grounds: Pursuant to Article XIII Section 280-53 the Bulk Schedule requires 80,000 sq. ft. per use in the MII zone district. The proposed wireless telecommunications facility use constitutes a second principal use on this 41,346 sq. ft. lot in the MII zone district. In addition the Bulk Schedule requires a minimum rear yard setback of 25 feet and maximum lot coverage of 30%. The proposed facility has a rear yard setback of 8 feet and lot coverage at 32%. Furthermore the proposed use requires site plan approval from the Southold Town Planning Board. Authorized Signature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. RECEIVED FORM NO. 3 AUG 0 9 2023 TOWN OF SOU'I-IOLD BUILDING DEPARTMENT Zoning (Board o Appeals SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL DATE: January 18, 2023 TO: Gregory R. Alvarez (Budd's Pond Marina) 666 Old Country Road, Suite 901 Garden City, NY 11530 Please take notice that your application dated January 4,2023: For permit: _to construct a new wireless telecommunications facility: Location of property: 61405 Main Road. Southold, NY County Tax Map No. 1000 - Section 56 Block 3 Lot 15 Is returned herewith and disapproved on the following grounds: Pursuant to Article XIII Section 280-53 the Bulk Schedule requires 80,000 sq ft per use in the MII zone district. The proposed wireless telecommunications facility use constitutes a second principal use on this 41,346 sq. ft. lot in the MII zone district In addition, the Bulk Schedule requires a minimum rear yard setback of 25 feet and maximum lot coverage of 30%. The proposed facility has a rear vard setback of 8 feet and lot coverage at 32%. Furthermore, the proposed use requires site plan approval from the Southold Town Planning Board. Authorize Signature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. ZBA, Planning,file I Fee:$�_Filed By: Assignment No. G 0 9 2023 APPLICATION TO THE SOUTHOLD TOWN BOARD OF P �783Q) AREA VARIANCE Board of A peals House No. 61405 Street Main Road Hamlet Southold SCTM 1000 Section 56 Block 3 Lot(s) 15 Lot Size 41,346 Zone Marine Il I(WE)APPEAL THE WRITTEN DETERMINATION OF THE BUILDING INSPECTOR DATED January 18, 2023 BASED ON SURVEY/SITE PLAN DATED January 3, 2023 Owner(s): Budd's Pond Marina, Inc. Contact Person: William M. Witzke Mailing Address: 61405 Main Road, Southold, NY 11971 Telephone:(631) 765-3232 Fax: Email: Bill@AlbertsonMarine.com NOTE:In addition to the above please complete below if application is signed by applicant's attorney,agent,architect, builder,contract vendee,etc.and name of person who agent represents: Name of Representative: Gregory R. Alvarez, Esq. for( ) Owner(Other: Applicant Elite Towers, LP Address: Amato Law Group, PLLC, 666 Old Country Rd., Ste. 901, Garden City, NY 11530 Telephone:(516) 227-6363 Fax:(516) 227-6367 Email:galvarez@amatofirm.com Please check to specify who you wish correspondence to be marled to,from the above names: ( )Applicant/Owner(s), ()�Authorized Representative, ( ) Other Name/Address below: WHEREBY THE BUILDING INSPECTOR REVIEWED SURVEY/SITE PLAN DATEDJanuary 3, 2023 and DENIED AN APPLICATION DATEDJan. 4, 2022 FOR: (�Building Permit ( ) Certificate of Occupancy ( )Pre-Certificate of Occupancy ( ) Change of Use ( ) Permit for As-Built Construction ( ) Other: Provision of the Zoning Ordinance Appealed. (Indicate Article,Section,Subsection of Zoning Ordinance by numbers.Do not quote the code.) Article:XI I I Section: 280-53 Subsection: Type of Appeal. An Appeal is made for: (X)A Variance to the Zoning Code or Zoning Map. ( ) A Variance due to lack of access required by New York Town Law- Section 280-A. ( )Interpretation of the Town Code,Article Section ( )Reversal or Other A prior appeal( )has, (>� has not been made at any time with respect to this property,UNDER Appeal No(s). Year(s). . (Please be sure to research before completing this question or call our office for assistance) Name of Owner: ZBA File# r r' RECEIVED REASONS FOR APPEAL (Please be specific, additional sheets may be used with prepay 's signature notarized): AUG U 9 2023 1.An undesirable change will not be produced in the CHARACTER of the neighbor or a detrime t � 3 properties if granted,because: Z®ia }Board of Appeals of the passive nature of the proposed use, which will only require periodic visits for facility maintenance. (Further support to be provided as part of application submissions.) 2.The benefit sought by the applicant CANNOT be achieved by some method feasible for the applicant to pursue, other than an area variance,because: of the existing conditions of the property. (Further support to be provided as part of application submissions.) 3.The amount of relief requested is not substantial because: of the passive nature of the proposed use, which will only require periodic visits for facility maintenance. (Further support to be provided as part of application submissions.) 4.The variance will NOT have an adverse effect or impact on the physical or environmental conditions in the neighborhood or district because: of the passive nature of the proposed use, which will only require periodic visits for facility maintenance. (Further support to be provided as part of application submissions.) 5.Has the alleged difficulty been self-created? { } Yes,or N No Why: The parcel is the only site within the area which is available and feasible to locate the proposed facility to address the service deficiencies in the least obtrusive way. (Further support provided.) Are there any Covenants or Restrictions concerning this land? {4 No { } Yes(please furnish a copy) This is the MINIMUM that is necessary and adequate,and at the same time preserve and protect the character of the neighborhood and the health,safety and welfare of the community. New York SMSA Limited Partnership d/b/a Verizon Wireless, as Signature of pplic t or Authorized Agent (Agent must subm' i n Authorization from Ow'nert B Robert Czarniawski Sworn to before me this 2-L day Title: Nbtwork Engineer - Real Estate of /Y)//1r! 1 20_Z3_. 0— J1�4 14 Cary Public- INDIA ub isINDIA DECARMINE NOTARY PUBLIC-STATE OF NEW YORK No,02DE5060491 Qualified in Suffolk County 2,D, My Commission Expires 05-202 RECETVED REASONS FOR APPEAL(Please he.specific,additional sheets may he used with preparer's AUG ,P9 20Q2/3 signature notarized): Zoning Board Of H 1.An undesirable change will not be produced in the CHARACTER of the neighbor or a detriment t 9 PPedIS properties if granted,because: of the passive nature of the proposed use, which will only require periodic visits for facility maintenance. (Further support to be provided as part of application submissions.) 2.The benefit sought by the applicant CANNOT be achieved by some method feasible for the applicant to pursue, other than an area variance,because: of the existing conditions of the property. (Further support to be provided as part of application submissions.) 3.The amount of relief requested is not substantial because: of the passive nature of the proposed use, which will only require periodic visits for facility maintenance. (Further support to be provided as part of application submissions.) 4.The variance will NOT have an adverse effect or impact on the physical or environmental conditions in the neighborhood or district because: of the passive nature of the proposed use, which will only require periodic visits for facility maintenance. (Further support to be provided as part of application submissions.) 5.Has the alleged difficulty been self-created? ())Yes,or( )No Why: By locating the additional use on the property. However, as noted, the requested relief will not have an adverse impact on the property or surrounding area. (Further support to follow.) Are there any Covenants or Restrictions concerning this land? {X No {)Yes(please furnish a copy) This is the MINIMUM that is necessary and adequate,and at the same time preserve and protect the character of the neighborhood and the health,safety and welfare of the community. DISH Wireless LLC, as Co-Applicant Signature of Applicant or Authorized Agent (Agent must submit written Authorization from Owner) S o b,fore me this ay By: of 20 1�1�11�11j1�11�� .' Notary Public `�%%`$•1�;;`.:': �P 'U b � RECEIVED APPLICANT'S PROJECT DESCRIPTION AUG 0 9 2023 APPLICANT: Elite Towers, LPDATE PREPARE Zoning Board o Appeals ; 1. For Demolition of Existing Building Areas Please describe areas being removed: existing impervious material in construction area II. New Construction Areas (New Dwelling or New Add itions/Extensions): Dimensions of first floor extension: N/A Dimensions of new second floor: Dimensions of floor above second level: Height(from finished ground to top of ridge): Is basement or lowest floor area being constructed?If yes, please provide height(above ground) measured from natural existing grade to first floor: III. Proposed Construction Description (Alterations or Structural Changes) (Attach extra sheet if necessary). Please describe building areas: Number of Floors and General Characteristics BEFORE Alterations: Existing impervious area Number of Floors and Changes WITH Alterations: ons ruc Ion o a newconcea men po e and accompanying ground equipment area as more fully described on the accompanying drawings IV. Calculations of building areas and lot coverage(from surveyor): Existing square footage of buildings on your pproperty: +/- 10,800 square feet Proposed increase of building coverage: N/A Square footage of your lot: +/- 41,346 square 1661 Percentage of coverage of your lot by building area: 26.2% existing/32% proposed V. Purpose of New Construction: To provide needed wireless coverage to subscribers (in the instance of Verizon Wireless and DISH Wireless) and for emer envy communications (for the Southold Fire District) within the area around the subject parcel. VI. Please describe the land contours(flat,slope %, heavily wooded,marsh area,etc.)on your land and how it relates to the difficulty in meeting the code requirement(s): Flat. Please submit 8 sets of photos, labeled to show different angles of yard areas after staking corners for new construction,and photos of building area to be altered with yard view. 4/2012 QUESTIONNAIRE FOR FILING WITH YOUR ZBA APPLICATION RECEIVED A. Is the subject premises listed on the real estate market for sale? AUG 0 9 2023 Yes X No W39 B. Are there an Zoning Board bf Appeals y proposals to change or alter land contours? No X Yes please explain on attached sheet, C. 1.) Are there areas that contain sand or wetland grasses? No 2.) Are those areas shown on the survey submitted with this application? 3.) Is the property bulk headed between the wetlands area and the upland building area? No 4.) If your property contains wetlands or pond areas, have you contacted the Office of the Town trustees for its determination of jurisdiction? PIease confirm status of your inquiry or application with the Trustees: Application to be filed (wetlands and if issued, please attach copies of permit with conditions and approved survey. on adjacent lot) D. Is there a depression or sloping elevation near the area of proposed construction at or below five feet above mean sea level? No E. Are there any patios, concrete barriers, bulkheads or fences that exist that are not shown on the survey that you are submitting? No Please show area of the structures on a diagram if any exist or state none on the above line. F. Do you have any construction taking place at this time concerning your premises? No If yes, please submit a copy of your building permit and survey as approved by the Building Department and please describe: G. Please attach all pre-certificates of occupancy and certificates of occupancy for the subject premises. If any are lacking, please apply to the Building Department to either obtain them or to obtain an Amended Notice of Disapproval. H. Do you or any co-owner also own other land adjoining or close to this parcel? No If yes, please label the proximity of your lands on your survey. I. Please list present use or operations conducted at this parcel boat storage and repairs and the proposed use Public utility wireless communications facility (ex: existing single family, proposed: same with garage, pool or other) New York SMSA Limited Partnership d/b/a/Verizon Wireless, as Co-Applicant Authorized sigatur and Date By Robert Cza ski Title: NEtwork Engineer - REal Estate FORM NO. 4 RECEIVED TOWN OF SOUTHOLD BUILDING DEPARTMENT AUG 0 9 2023 Town Clerk's Office 13 Mppeals Southold, N. Y. Zoning Board Certificate Of Occupancy No 2h9. . . . . . . Date . . . . . . . . . . . .Oct. . . .11. . . . . . .. 19. 2. r THIS CERTIFIES that the building located at I/S. slain Boa& . . . . . . . . . . . Street Map No.=. . . . . . . . . . Block No. . . g. . . . .Lot No: .ZZy . • •110athold • •N-eY; . . . . . . . . conforms substantially to the Application for Building Permit heretofore filed in this office dated . . . . . . . . . . . . . .Mep. . .1,9, 19. .72 pursuant to which Building Permit No. .53122 . dated . . . . . . .. . .May . . .19. . . . .. 19-7.2 ., was issued, and conforms to all of the require- ments of the applicable provisions of the law. The occupancy for which this certificate is issued is . Business. building— 1'vat• .starage. .*to-. .(Southold. Yishing.Sta.) The certificate is issued to .Richge1 .Morrls. . . . . . . . Owner. . . . . . . . . . . . . . . . . . . . . . . . (owner, lessee or tenant) of the aforesaid building. Suffolk County Department of Health Approval N,.R. • • • • • • • • • • • • • • • • • • • • • • • • • . UNDERWRITERS CERTIFICATE No. . . .N,R.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I . . . . . . HOUSF NUMBER. . 014.7 . . . .Street. . . . X4ia. Awad. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Building Inspector FORM NU. 4 RECEIVED TOWN OF SOUTHOLD AUG 0 9)2023 13 UILDING DEPARTMENT -79-3q TOWN CLERK'S OFFICE SOUTHOLD, N. Y. Zoning Board f Appeals CERTIFICATE OF OCCUPANCY No. Z 837...... Date octobn 19 . , 1960. THIS CERTIFIES that the building located at 0/3 D+&irt.RMA4 . .80►t t12 03-d. Street Map No. .. Block No. ILbt No. * tt conforms substantially to the Application for Building Pcrinit heretofore filed in this office dated .. ... ... . November 24191?•. pursuaint to which Building Permit No.L°909 ... . ,3ated .............. November 24 59 .,,. ,.. . . 19 . , was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is BUSINESS SU:KLDIKCi:. R40k�,. 1tPQR�CBOP .GARAaE This certificate is issued to Ddel3 t & Xicbaal Morris,...Gwaoxa ••• ..................••• ••. (owner, lessee or tenant) of the aforesaid building. ..... . .. ...... ...... . .. . . ... .... Building Inspector i AGRICULTURAL DATA STATEMENT RECEIVED ZONING BOARD OF APPEALS AUG 092023 TOWN OF SOUTHOLD 1$ 3 Zoning Board of WHEN TO USE THIS FORM: This form must be completed by the applicant or APPeals permit, site plan approval, use variance, area variance or subdivision approval on property within an agricultural district OR within 500 feet of a farm operation located in an agricultural district. All applications requiring an agricultural data statement must be referred to the Suffolk County Department of Planning in accordance with Section 239m and 239n of the General Municipal Law. I. Name of Applicant: Elite Towers, LP 2. Address of Applicant: 1 South Durkee Lane East Patchogue, NY 11772 3. Name of Land Owner(if other than Applicant): Budd's Pond Marina, Inc. 4. Address of Land Owner: 61405 Main Road, Southold, NY 11971 5. Description of Proposed Project: construct and maintain a new public utility wireless communications facility 6. Location of Property: (road and Tax map number) 61405 Main Road, Southold, NY SCTM # 1000-56-3-15 7. Is the parcel within 500 feet of a farm operation? { } Yes {)§ No 8. Is this parcel actively farmed? { } Yes { } No 9. Name and addresses of any owner(s) of land within the agricultural district containing active farm operations. Suffolk County Tax Lot numbers will be provided to you by the Zoning Board Staff, it is your responsibility to obtain the current names and mailing addresses from the Town Assessor's Office (765-1937) or from the Real Property Tax Office located in Riverhead. NAME and ADDRESS 1. bl o .Po-nd A-g SwAwid IJofil.m ly�- �(I 2. 5(v — 1-11,12-- n o� c 3. b — 3—t 3.3 (10as P_ tau, arfim fie, vvc 4. 5. 6. Please use the back of this page if there are additional property owners) ew MS Limited Partnership d/b/a Verizon Wireless, as Co-Applicant 3 / Zq / w7_:5 Signature of A li nt By: Robert czarniawski Date Note: Co- l. The local Board will solicit comments from the owners of land identified above in order to consider the effect of the proposed action on their farm operation. Solicitations will be made by supplying a copy of this statement. 2. Comments returned to the local Board will be taken into consideration as part as the overall review of this application. 3. Copies of the completed Agricultural Data Statement shall be sent by applicant to the property owners identified above. The cost for mailing shall be paid by the Applicant at the time the application is submitted for review. RECEIVED 1 :Environmental Assessment Form Part I -Project and Setting AUG 0 9 2023 3 Instructions for Completing Part 1 Zoning Board of Appeals Part 1 is to be completed by the applicant or project sponsor. Responses become part of the application for approval or funding, are subject to public review,and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item,please answer as thoroughly as possible based on current information;indicate whether missing information does not exist, or is not reasonably available to the sponsor;and,when possible,'generally describe work or studies which would be necessary to update or fully develop that information. Applicants/sponsors must complete all items in Sections A&B. In Sections C,D&E,most items contain an initial question that must be answered either"Yes"or"No". If the answer to the initial question is"Yes",complete the sub-questions that follow. If the answer to the initial question is"No",proceed to the next question. Section F allows the project sponsor to identify and attach any additional information. Section G requires the name and signature of the applicant or project sponsor to verify that the information contained in Part lis accurate and complete. A.Project and Applicant/Sponsor Information. Name of Action or Project: Proposed Wireless Communications Facility-Albertson Marine Project Location(describe,and attach a general location map): 61405 Main Road,hamlet of Southold,Town of Southold,Suffolk County,New York(SCTM:District 1000-Section 05600-Block 03.00-Lot 015.000) Brief Description of Proposed Action(include purpose or need): See Attachment Name of Applicant/Sponsor: Telephone:See Project Contact See Attachment E-Mail: See Project Contact Address:See Attachment City/PO:See Attachment State:See Attachment Zip Code: Project Contact(if not same as sponsor;give name and title/role): Telephone:(516)227-6363 Gregory R.Alvarez,Esq.,Amato Law Group,PLLC E-Mail: galvarez@amatofirm.com Address: 666 Old Country Road,Suite 901 City/PO: State: Zip Code: Garden City New York 11530 Property Owner (if not same as sponsor): Telephone: (631)765-3232 Budd's Pond Marina,Inc. E-Mail: Bill@albertsonmarine.com Address: 61405 Main Road City/PO: Southold State: NY Zip Code:11971 Page 1 of 13 FEAF 2019 B.Government Approvals See Attachment B.Government Approvals,Funding,or Sponsorship. ("Funding"includes grants,loans,tax relief,and any other forms of financial assistance.) Government Entity If Yes:Identify Agency and Approval(s) Application Date Required (Actual or projected) a.City Counsel,Town Board, ®YesONo or Village Board of TrusteesPC j�JC� b.City,Town or Village OieS0No Planning Board or Commission 9 2M c.City,Town or ®YesE3No ✓]f Village Zoning Board of Appeals r- d.Other local agencies OYesE]No zoning Boa e.County agencies DYes®No f.Regional agencies QYes®No g.State agencies ®YeS0No h.Federal agencies DYes®No i. Coastal Resources. i. Is the project site within a Coastal Area,or the waterfront area of a Designated Inland Waterway? ®Yes❑No ii. Is the project site located in a community with an approved Local Waterfront Revitalization Program? ®Yes❑No iii. Is the project site within a Coastal Erosion Hazard Area? ❑Yes®No C.Planning and Zoning C.I.Planning and zoning actions. Will administrative or legislative adoption,or amendment of a plan,local law,ordinance,rule or regulation be the ❑Yes®No only approval(s)which must be granted to enable the proposed action to proceed? • If Yes,complete sections C,F and G. • If No,proceed to question C.2 and complete all remaining sections and questions in Part 1 C.2.Adopted land use plans. a.Do any municipally-adopted (city,town,village or county)comprehensive land use plan(s)include the site ®YeS[ NO where the proposed action would be located? If Yes,does the comprehensive plan include specific recommendations for the site where the proposed action ❑Yes®No would be located? b.Is the site of the proposed action within any local or regional special planning district(for example: Greenway; ®YesElNo Brownfield Opportunity Area(BOA);designated State or Federal heritage area;watershed management plan; or other?) If Yes,identify the plan(s): Long Island North Shore Heritage Area c. Is the proposed action located wholly or partially within an area listed in an adopted municipal open space plan, ❑Yes®No or an adopted municipal farmland protection plan? If Yes,identify the plan(s): Page 2 of 13 C.3. Zoning a. Is the site of the proposed action located in a municipality with an adopted zoning law or ordinance. ®Yes❑No If Yes,what is the zoning classification(s)including any applicable overlay district? Marine II(MII)District of the Town of Southold b. Is the use permitted or allowed.by a special or conditional use permit? REC ®Yes❑No c.Is a zoning change requested as part of the proposed action? (•�2 t� ❑Yes®No If Yes, AUG 0 9 2023) / L What is the proposed new zoning for the site? 11 CA.Existing community services. Zoning Board of Appeals a.In what school district is the project site located?Southold Union Free School District b.What police or other public protection forces serve the project site? Southold Town Police Department c.Which fire protection and emergency medical services serve the project site? Southold Fire Department(fire protection and emergency medical services) d.What parks serve the project site? N/A The proposed wireless communications facility is unmanned and will not place a demand on or utilize parks D.Project Details D.I.Proposed and Potential Development a.What is the general nature of the proposed action(e.g.,residential,industrial,commercial,recreational;if mixed,include all components)? Public Utility-Wireless Communications Facility b.a.Total acreage of the site of the proposed action? 0.951 acres (overall Subject Property) b.Total acreage to be physically disturbed? 0.08± acres c.Total acreage(project site and any contiguous properties)owned or controlled by the applicant or project sponsor? 0.06± acres c.Is the proposed action an expansion of an existing project or use? ❑Yes®No i. If Yes,what is the approximate percentage of the proposed expansion and identify the units(e.g.,acres,miles,housing units, square feet)? % Units: d.Is the proposed action a subdivision,or does it include a subdivision? ❑Yes ONo If Yes, i.Purpose or type of subdivision?(e.g.,residential,industrial,commercial;if mixed,specify types) H. Is a cluster/conservation layout proposed? ❑Yes❑No iii.Number of lots proposed? iv. Minimum and maximum proposed lot sizes? Minimum Maximum e.Will the proposed action be constructed in multiple phases? ❑Yes®No i. If No,anticipated period of construction: 41 months H. If Yes: • Total number of phases anticipated • Anticipated commencement date of phase 1(including demolition) month year • Anticipated completion date of final phase month year • Generally describe connections or relationships among phases,including any contingencies where progress of one phase may determine timing or duration of future phases: 'Refers to proposed 70±-foot-by-35±-foot fenced equipment compound. Page 3 of 13 f.Does the project include new rf _._ atial uses? —-8014440 If Yes,show numbers of units proposed. Rr;CET\/F-D One Family Two Family Three Family Multiple Famil four or more Initial Phase AUGQ 9 2023 At completion of all phases p0 3 —ZonIngoard'ofAppeals g.Does the proposed action include new non-residential construction(including expansions)? No If Yes, i.Total number of structures 2 (proposed concealment pole and equipment platform) ii. Dimensions(in feet)of largest proposed structure: 164'10"t*height; 35t**width; and lot**length iii. Approximate extent of building space to be heated or cooled: N/A square feet h.Does the proposed action include construction or other activities that will result in the impoundment of any ❑Yes®No liquids,such as creation of a water supply,reservoir,pond,lake,waste lagoon or other storage? If Yes, L Purpose of the impoundment: ii. If a water impoundment,the principal source of the water: ❑Ground water❑Surface water streams ❑Other specify: iii. If other than water,identify the type of impounded/contained liquids and their source. iv. Approximate size of the proposed impoundment. Volume: million gallons;surface area: acres v. Dimensions of the proposed dam or impounding structure: height; length vi. Construction method/materials for the proposed dam or impounding structure(e.g.,earth fill,rock,wood,concrete): D.2. Project Operations a.Does the proposed action include any excavation,mining,or dredging,during construction,operations,or both? ❑Yes❑No (Not including general site preparation,grading or installation of utilities or foundations where all excavated materials will remain onsite) To be determined upon design of concealment pole foundation. If Yes: i.What is the purpose of the excavation or dredging? ii. How much material(including rock,earth,sediments,etc.)is proposed to be removed from the site? • Volume(specify tons or cubic yards): • Over what duration of time? iii. Describe nature and characteristics of materials to be excavated or dredged,and plans to use,manage or dispose of them. iv. Will there be onsite dewatering or processing of excavated materials? ❑Yes❑No If yes,describe. v. What is the total area to be dredged or excavated? acres vi. What is the maximum area to be worked at any one time? acres vii. What would be the maximum depth of excavation or dredging? feet viii. Will the excavation require blasting? ❑Yes❑No ix. Summarize site reclamation goals and plan: b.Would the proposed action cause or result in alteration of,increase or decrease in size of,or encroachment ❑Yes®No*** into any existing wetland,waterbody,shoreline,beach or adjacent area? If Yes: L Identify the wetland or waterbody which would be affected(by name,water index number,wetland map number or geographic description): *Refers to the top of the proposed fire district antennas atop the proposed concealment pole,measured from grade level. **Refers to the length and width of the proposed equipment compound. ***The location of the proposed wireless communication facility consists of a gravel-surfaced,upland area that is currently used for boat storage.The areas adjacent to the facility consist of upland development,including gravel surfaces,the existing site building,and the LIRR tracks. Page 4 of 13 ii. Describe how the proposed action woul��__ _'ect that waterbody or wetland,e.g.excavation placement of structures,or alteration of channels,banks and shorelines. Indicate extent of activities,alterations and additions in square feet or acres: iii.Will the proposed action cause or result in disturbance to bottom sediments? ❑YeS❑NO If Yes,describe: iv. Will the proposed action cause or result in the destruction or removal of aquatic vegetation? ❑Yes❑No If Yes: • acres of aquatic vegetation proposed to be removed: • expected acreage of aquatic vegetation remaining after project completion: EIV • purpose of proposed removal(e.g.beach clearing,invasive species control,boat access): • proposed method of plant removal: • if chemical/herbicide treatment will be used,specify product(s): v. Describe any proposed reclamation/mitigation following disturbance: oar of q c.Will the proposed action use,or create a new demand for water? []Yes ONo If Yes: (Unmanned facility,no demand for potable water) L Total anticipated water usage/demand per day: gallons/day ii. Will the proposed action obtain water from an existing public water supply? ❑Yes ONO If Yes: • Name of district or service area: • Does the existing public water supply have capacity to serve the proposal? ❑Yes❑No • Is the project site in the existing district? ❑Yes❑No • Is expansion of the district needed? ❑Yes❑No • Do existing lines serve the project site? ❑Yes❑No iii. Will line extension within an existing district be necessary to supply the project? ❑Yes❑No If Yes: • Describe extensions or capacity expansions proposed to serve this project: • Source(s)of supply for the district: iv.Is a new water supply district or service area proposed to be formed to serve the project site? ❑Yes❑No If,Yes: • Applicant/sponsor for new district: • Date application submitted or anticipated: • Proposed source(s)of supply for new district: v. If a public water supply will not be used,describe plans to provide water supply for the project: vi.If water supply will be from wells(public or private),what is the maximum pumping capacity: gallons/minute. d.Will the proposed action generate liquid wastes? ❑Yes®No If Yes: (Unmanned facility,no liquid waste generation) i. Total anticipated liquid waste generation per day: gallons/day ii.Nature of liquid wastes to be generated(e.g.,sanitary wastewater,industrial;if combination,describe all components and approximate volumes or proportions of each): iii. Will the proposed action use any existing public wastewater treatment facilities? ❑Yes❑No If Yes: • Name of wastewater treatment plant to be used: • Name of district: • Does the existing wastewater treatment plant have capacity to serve the project? ❑Yes❑No • Is the project site in the existing district? ❑Yes❑No • Is expansion of the district needed? ❑Yes E]No Page 5 of 13 AML • Do existing sewer lines AWE the project site? 144W I ❑Yes❑No • Willa line extension within an existing district be necessary to serve the project? RECEIVED ❑Yes❑No If Yes: • Describe extensions or capacity expansions proposed to serve this pro ect: iv. Will anew wastewater(sewage)treatment district be formed to serve the projec skb7iing Board of AppeaIS ❑Yes❑No If Yes: • Applicant/sponsor for new district: • Date application submitted or anticipated: • What is the receiving water for the wastewater discharge? v. If public facilities will not be used,describe plans to provide wastewater treatment for the project,including specifying proposed receiving water(name and classification if surface discharge or describe subsurface disposal plans): vi. Describe any plans or designs to capture,recycle or reuse liquid waste: e.Will the proposed action disturb more than one acre and create stormwater runoff,either from new point ❑Yes®No sources(i.e.ditches,pipes,swales,curbs,gutters or other concentrated flows of stormwater)or non-point source(i.e.sheet flow)during construction or post construction? If Yes: i. How much impervious surface will the project create in relation to total size of project parcel? Square feet or acres(impervious surface) Square feet or acres(parcel size) U. Describe types of new point sources. iii. Where will the stormwater runoff be directed(i.e.on-site stormwater management facility/structures,adjacent properties, groundwater,on-site surface water or off-site surface waters)? • If to surface waters,identify receiving water bodies or wetlands: • Will stormwater runoff flow to adjacent properties? ❑Yes❑No iv. Does the proposed plan minimize impervious surfaces,use pervious materials or collect and re-use stormwater? ❑Yes❑No f. Does the proposed action include,or will it use on-site,one or more sources of air emissions,including fuel ❑Yes®No combustion,waste incineration,or other processes or operations? If Yes,identify: i.Mobile sources during project operations(e.g.,heavy equipment,fleet or delivery vehicles) ii. Stationary sources during construction(e.g.,power generation,structural heating,batch plant,crushers) W. Stationary sources during operations(e.g.,process emissions,large boilers,electric generation) g.Will any air emission sources named in D.2.f(above),require a NY State Air Registration,Air Facility Permit, ❑Yes®No or Federal Clean Air Act Title IV or Title V Permit? If Yes: i. Is the project site located in an Air quality non-attainment area? (Area routinely or periodically fails to meet ❑Yes❑No ambient air quality standards for all or some parts of the year) ii. In addition to emissions as calculated in the application,the project will generate: • Tons/year(short tons)of Carbon Dioxide(CO2) • Tons/year(short tons)of Nitrous Oxide(N20) • Tons/year(short tons)of Perfluorocarbons(PFCs) • Tons/year(short tons)of Sulfur Hexafluoride(SF6) • Tons/year(short tons)of Carbon Dioxide equivalent of Hydroflourocarbons(HFCs) • Tons/year(short tons)of Hazardous Air Pollutants(HAPS) _ Page 6 of 13 h.Will the proposed action generate or emit Wane(including,but not limited to sewage R a',Di s, ❑Yes®No landfills,composting facilities)? If Yes: AUG 0 9 2023 L Estimate methane generation in tons/year(metric): ii.Describe any methane capture,control or elimination measures included in pro ect design(e.g.,combustion to enerate heat or electricity,flaring): I Zoning Board of Appeals i.Will the proposed action result in the release of air pollutants from open-air operations or processes,such as ❑Yes®No quarry or landfill operations? If Yes:Describe operations and nature of emissions(e.g.,diesel exhaust,rock particulates/dust): j.Will the proposed action result in a substantial increase in traffic above present levels or generate substantial ❑Yes®No new demand for transportation facilities or services? The unmanned facility will generate approximately one trip per month per carrier to If Yes: inspect and maintain equipment. L When is the peak traffic expected(Check all that apply): ❑Morning ❑Evening ❑Weekend ❑Randomly between hours of to ii.For commercial activities only,projected number of truck trips/day and type(e.g.,semi trailers and dump trucks): iii. Parking spaces: Existing Proposed Net increase/decrease iv.Does the proposed action include any shared use parking? E ❑No v. If the proposed action includes any modification of existing roads,creation of new roads or change in existing access,describe: vi. Are public/private transportation service(s)or facilities available within V2 mile of the proposed site? ❑Yes❑No vii Will the proposed action include access to public transportation or accommodations for use of hybrid,electric ❑Yes❑No or other alternative fueled vehicles? viii.Will the proposed action include plans for pedestrian or bicycle accommodations for connections to existing ❑Yes❑No pedestrian or bicycle routes? k.Will the proposed action(for commercial or industrial projects only)generate new or additional demand ®Yes❑No for energy? If Yes: L Estimate annual electricity demand during operation of the proposed action: A minimal increase in electricity usage associated with the operation of the proposed wireless communications facility is anticipated. ii. Anticipated sources/suppliers of electricity for the project(e.g.,on-site combustion,on-site renewable,via grid/local utility,or other): Via connection to existing grid(LIPA Go PSEG Long Island) iii. Will the proposed action require a new,or an upgrade,to an existing substation? ❑Yes®No 1.Hours of operation. Answer all items which apply. i. During Construction: ii. During Operations: • Monday-Friday: 0 Monday-Friday: 24 hours per day** • Saturday: • Saturday: 24 hours per day** • Sunday: • Sunday: 24 hours per day** • Holidays: None • Holidays: 24 hours per day** *Sunday-Thursday:7:00 a.m.-7:00 p.m.,Friday-Saturday:7:00 a.m.-11:00p.m.,in accordance with Chapter 180 of the Southold Town Code:Prevention of Noise. **Remotely monitored,unmanned wireless communications facility. Page 7 of 13 RECEIVED m.Will the proposed action prod%___Noise that will exceed existing ambient nois le __._.'Turing construction, ®Yes[]No operation,or both? AUG ® 9 2023 If yes: ..... . . ���A L Provide details including sources,time of day and duration: I Ambient noise levels may be temporarily exceeded during construction activities which woull bZord QD@ir6baf* 8M1fe I applicable Town regulations. ii. Will the proposed action remove existing natural barriers that could act as a noise barrier or screen? ❑Yes®No Describe: n.Will the proposed action have outdoor lighting? ®Yes❑No If yes: L Describe source(s),location(s),height of fixture(s),direction/aim,and proximity to nearest occupied structures: Proposed outdoor lighting fixtures include timed lights on the proposed equipment platforms.The lights are to be used intermittently during maintenance activities and would not shine onto adjacent properties. ii. Will proposed action remove existing natural barriers that could act as a light barrier or screen? ❑Yes®No Describe: o.Does the proposed action have the potential to produce odors for,more than one hour per day? ❑Yes®No If Yes,describe possible sources,potential frequency and duration of odor emissions,and proximity to nearest occupied structures: p.Will the proposed action include any bulk storage of petroleum(combined capacity of over 1,100 gallons) ❑Yes®No or chemical products 185 gallons in above ground storage or any amount in underground storage? If Yes: L Product(s)to be stored ii. Volume(s) per unit time (e.g.,month,year) id. Generally,describe the proposed storage facilities: q.Will the proposed action(commercial,industrial and recreational projects only)use pesticides(i.e.,herbicides, ❑Yes ®No insecticides)during construction or operation? If Yes: L Describe proposed treatment(s): ii. Will the proposed action use Integrated Pest Management Practices? ❑ Yes ❑No r.Will the proposed action(commercial or industrial projects only)involve or require the management or disposal ❑ Yes ®No of solid waste(excluding hazardous materials)? If Yes: L Describe any solid waste(s)to be generated during construction or operation of the facility: • Construction: tons per (unit of time) • Operation: tons per (unit of time) ii. Describe any proposals for on-site minimization,recycling or reuse of materials to avoid disposal as solid waste: • Construction: • Operation: iii. Proposed disposal methods/facilities for solid waste generated on-site: • Construction: • Operation: Page 8 of 13 s.Does the proposed action include construe,_ or modification of a solid waste management i _ _ .y? ❑Yes® No If Yes: i. Type of management or handling of waste proposed for the site(e.g.,recycling or transfer stati =rr other disposal activities): ii. Anticipated rate of disposal/piocessing: Tons/month,if transfer or other non-combustion/thermal treatment,or AUG 0 9 2023 Tons/hour,if combustion or thermal treatment iii. If landfill,anticipated site life: years t.Will the proposed action at the site involve the commercial generation,treatment,storage,or dis osa o �s waste? If Yes: i. Name(s)of all hazardous wastes or constituents to be generated,handled or managed at facility: ii. Generally describe processes or activities involving hazardous wastes or constituents: iii.Specify amount to be handled or generated tons/month iv. Describe any proposals for on-site minimization,recycling or reuse of hazardous constituents: v. Will any hazardous wastes be disposed at an existing offsite hazardous waste facility? ❑Yes❑No If Yes:provide name and location of facility: If No:describe proposed management of any hazardous wastes which will not be sent to a hazardous waste facility: E.Site and Setting of Proposed Action E.I.Land uses on and surrounding the project site a.Existing land uses. i. Check all uses that occur on,adjoining and near the project site. ❑ Urban ❑ Industrial ® Commercial ® Residential(suburban) ❑ Rural(non-farm) ❑ Forest ® Agriculture ® Aquatic ® Other(specify):Open Space Transportation(Long Island Rail Road[LIRR]) ii. If mix of uses,generally describe: The Subject Property is a boat storage and maintenance facility in a mixed-use corridor containing the LIRR open space,agricultural,residential,commercial (e.g.,marinas,restaurants),and vacant uses.The Subject Property is situated between the LIRR to the north and Main Road(NYS Route 25)to the south. b.Land uses and covertypes on the project site. Land use or Current Acreage After Change Covertype Acreage Project Completion (Acres+/-) • Roads,buildings,and other paved or impervious 0.94± 0.90± 0.04± surfaces • Forested 0 0 0 • Meadows,grasslands or brushlands(non- 0 0 0 agricultural,including abandoned agricultural) • Agricultural 0 0 0 (includes active orchards,field,greenhouse etc.) • Surface water features 0 0 0 (lakes,ponds,streams,rivers,etc.) • Wetlands(freshwater or tidal) 0 0 0 • Non-vegetated(bare rock,earth or fill) 0 0 0 • Other Describe:Landscaped 0.01± 0.05± +0.04± Page 9 of 13 c.Is the project site presently uses 'members of the community for public recreati___ ❑Yes®No i. If Yes:explain: d.Are there any facilities serving children,the elderly,people with disabilities(e.g.,schoolQ s A#k1Aiqpnsed ❑Yes®No day care centers,or group homes)within 1500 feet of the project site? If Yes, AUG 0 9 2023 i. Identify Facilities: e.Does the project site contain an existing dam? ❑Yes®No If Yes: i. Dimensions of the dam and impoundment: • Dam height: feet • Dam length: feet • Surface area: acres • Volume impounded: gallons OR acre-feet ii. Dam's existing hazard classification: iff.Provide date and summarize results of last inspection: £Has the project site ever been used as a municipal,commercial or industrial solid waste management facility, ❑Yes®No or does the project site adjoin property which is now,or was at one time,used as a solid waste management facility? - If Yes: i. Has the facility been formally closed? ❑Yes❑ No • If yes,cite sources/documentation: ii. Describe the location of the project site relative to the boundaries of the solid waste management facility: iii. Describe any development constraints due to the prior solid waste activities: g.Have hazardous wastes been generated,treated and/or disposed of at the site,or does the project site adjoin ❑Yes®No property which is now or was at one time used to commercially treat,store and/or dispose of hazardous waste? If Yes: i. Describe waste(s)handled and waste management activities,including approximate time when activities occurred: h. Potential contamination history. Has there been a reported spill at the proposed project site,or have any ❑Yes® No remedial actions been conducted at or adjacent to the proposed site? If Yes: i. Is any portion of the site listed on the NYSDEC Spills Incidents database or Environmental Site ❑Yes❑No Remediation database? Check all that apply: ❑ Yes—Spills Incidents database Provide DEC ID number(s): ❑ Yes—Environmental Site Remediation database Provide DEC ID number(s): ❑ Neither database ii. If site has been subject of RCRA corrective activities,describe control measures: W. Is the project within 2000 feet of any site in the NYSDEC Environmental Site Remediation database? ❑Yes❑No If yes,provide DEC ID number(s): iv. If yes to(i),(ii)or(iii)above,describe current status of site(s): Page 10 of 13 v.Is the project site subject to an institutiot mtrol limiting property uses? _ ❑Yes®No • If yes,DEC site ID number: • Describe the type of institutional control(e.g.,deed restriction or easemen): RECEIVED • Describe any use limitations: • Describe any engineering controls: • Will the project affect the institutional or engineering controls in place? ❑Yes❑No • Explain: Zoning Boar of Apl5eals. E.2. Natural Resources On or Near Project Site a.What is the average depth to bedrock on the project site? loot feet below grade surface(bgs) b.Are there bedrock outcroppings on the project site? ❑Yes®No If Yes,what proportion of the site is comprised of bedrock outcroppings? % c.Predominant soil type(s)present on project site: Bd(Berryland mucky sand) 97.5±% Su(Sudbury sandy loam) 2.5±% d.What is the average depth to the water table on the project site? Average: 6± feet bgs e.Drainage status of project site soils:❑ Well Drained: %of site ®Moderately Well Drained: 2.5±%of site ® Poorly Drained 97.5±%of site f.Approximate proportion of proposed action site with slopes: ® 0-10%: 100 %of site ❑ 10-15%: %of site ❑ 15%or greater: %of site g.Are there any unique geologic features on the project site? ❑Yes®No If Yes,describe: h.Surface water features. i. Does any portion of the project site contain wetlands or other waterbodies(including streams,rivers, ❑Yes®No ponds or lakes)? ii.Do any wetlands or other waterbodies adjoin the project site? -]Yes[Z]No If Yes to either i or ii,continue. If No,skip to E.2.i. iii. Are any of the wetlands or waterbodies within or adjoining the project site regulated by any federal, ❑Yes❑No state or local agency? iv. For each identified regulated wetland and waterbody on the project site,provide the following information: • Streams: Name Classification Lakes or Ponds: Name Classification • Wetlands: Name Approximate Size • Wetland No.(if regulated by DEC) v. Are any of the above water bodies listed in the most recent compilation of NYS water quality-impaired El Yes❑No waterbodies? If yes,name of impaired water body/bodies and basis for listing as impaired: i.Is the project site in a designated Floodway? ❑Yes®No j.Is the project site in the 100-year Floodplain? ®Yes❑No k.Is the project site in the 500-year Floodplain? ❑Yes WINO 1.Is the project site located over,or immediately adjoining,a primary,principal or sole source aquifer? ®Yes❑No If Yes: i. Name of aquifer: Nassau-Suffolk Sole Source Aquifer `Wetlands occur beyond the LIRR tracks to the north of the Subject Property,beyond Main Road to the south of the Subject Properly,and in the general vicinity of the Subject Property at non-adjoining parcels to the east and west. Page 11 of 13 in. Identify the predominant wile:.._ pecies that occupy or use the project site: _ Pigeon,European Starling,Mourning Dove,House Sparrow,and similar common birds ecies a edlovr6tated,de/eloped conditions and high levels of human activity may utilize the Subject Property. n.Does the project site contain a designated significant natural community? AUG 0 9 2023 ❑Yes®No If Yes: i. Describe the habitat/community(composition,function,and basis for desig anion); U o I pea S ii. Source(s)of description or evaluation: iii.Extent of community/habitat: • Currently: acres • Following completion of project as proposed: acres • Gain or loss(indicate+or-): acres o.Does project site contain any species of plant or animal that is listed by the federal government or NYS as ®Yes❑No endangered or threatened,or does it contain any areas identified as habitat for an endangered or threatened species?` If Yes: L Species and listing(endangered or threatened): p. Does the project site contain any species of plant or animal that is listed by NYS as rare,or as a species of ❑Yes®No special concern? If Yes: L Species and listing: q.Is the project site or adjoining area currently used for hunting,trapping,fishing or shell fishing? ❑Yes®No If yes,give a brief description of how the proposed action may affect that use: E.3. Designated Public Resources On or Near Project Site a.Is the project site,or any portion of it,located in a designated agricultural district certified pursuant to ❑Yes®No Agriculture and Markets Law,Article 25-AA,Section 303 and 304? If Yes, provide county plus district name/number: b.Are agricultural lands consisting of highly productive soils present? ❑Yes®No i. If Yes:acreage(s)on project site? ii. Source(s)of soil rating(s): c. Does the project site contain all or part of,or is it substantially contiguous to,a registered National ❑Yes®No Natural Landmark? If Yes: i. Nature of the natural landmark: ❑Biological Community ❑ Geological Feature ii.Provide brief description of landmark,including values behind designation and approximate size/extent: d.Is the project site located in or does it adjoin a state listed Critical Environmental Area? ®Yes❑No If Yes: L CEA name: Peconic Bay and Environs(adjoining the Subject Property to the south) ii.Basis for designation: Protect public health,water,vegetation,and scenic beauty iii. Designating agency and date: Suffolk County,7-12-1988 'According to the NYSDEC EAF Mapper database,records for the federal/New York State listed species Piping Plover,Least Tern,and Common Tern, and a NYS Species of Special Concern-Black Skimmer,exist for the Subject Property vicinity.The Subject Property consists of developed upland areas and does not support the requisite aquatic and shoreline habitats for these shorebird species. Page 12 of 13 e.Does the project site contain,or is it subs illy contiguous to,a building,archaeological s .r district ❑Yes®No which is listed on the National or State Register of Historic Places,or that has been determined by the Commissioner of the NYS Office of Parks,Recreation and-Historic Preservation to be eligible for listing on the Sta ric Places? If Yes: LR�C:FIVED i.Nature of historic/archaeological resource: El Archaeological Site ❑Historic Bu7ding r is nct' ii.Name: iii. Brief description of attributes on which listing is based: AUb U 9 2023 f.Is the project site,or any portion of it,located in or adjacent to an area designated as se 1tRQlft9 Board of App ' s❑No archaeological sites on the NY State Historic Preservation Office(SHPO)archaeologica g.Have additional archaeological or historic site(s)or resources been identified on the project site? ❑Yes®No If Yes: i.Describe possible resource(s): ii. Basis for identification: h.Is the project site within fives miles of any officially designated and publicly accessible federal,state,or local ®Yes❑No scenic or aesthetic resource? If Yes: i. Identify resource: North Fork Trail(NYS Route 25) ii. Nature of,or basis for,designation(e.g.,established highway overlook,state or local park,state historic trail or scenic byway, etc.): Scenic Byway iii. Distance between project and resource: 200t feet . i. Is the project site located within a designated river corridor under the Wild,Scenic and Recreational Rivers ❑Yes®No Program 6 NYCRR 666? If Yes: L Identify the name of the river and its designation: ii. Is the activity consistent with development restrictions contained in 6NYCRR Part 666? ❑Yes❑No F.Additional Information Attach any additional information which may be needed to clarify your project. If you have identified any adverse impacts which could be associated with your proposal,please describe those impacts plus any measures which you propose to avoid or minimize them. G. Verification I certify that the information provided is true to the best of my knowledge. Elite Towers,LP;Verizon Wireless;Dish Wireless,LLC; Applicant/Sponsor Name Southold Fire District,as Co-Applicants Date June 7,2023 Signature Title Environmental Planner William Sklar,AICP VHB Engineering,Surveying,Landscape Architecture and Geology,P.C., as Environmental Consultant to the Co-Applicants PRINT FORM Page 13 of 13 Proposed Wireless Communications Facility-Albertson Marine 61405 Main Road R C[:J1/PD Hamlet of Southold,Town of Southold Suffolk County,New York AUG 092023 Part 1—Full Environmental Assessment Form zoning Boardpp A� pPals Attachment Page 1. Item A. Brief Description of Proposed Action: The Proposed Action involves the installation of a wireless communications facility, including a concealment pole and associated equipment, at 61405 Main Road in the hamlet of Southold,Town of Southold, Suffolk County, New York(the"Subject Property," see attached Site Location map). Specifically, the Proposed Action includes the installation of a 150±-foot above grade level (agl) concealment pole with the antennas of multiple wireless service carriers concealed within, and two Southold Fire District whip antennas mounted atop the concealment pole reaching a top height of 164-feet-l0±-inches agl.Six Verizon Wireless panel antennas would be installed within the concealment pole in three sectors(two panel antennas per sector) at centerline heights of 141-feet-2± inches agl and 146-feet-1± inch agl.Three Dish Wireless panel antennas would be installed within the concealment pole in three sectors (one panel antenna per sector) at a centerline height of 132± feet agl.There would be room for additional future wireless service carrier antennas within the concealment pole below the Verizon Wireless and Dish Wireless antennas. The concealment pole would be installed within a 70±-foot-by-35±-foot(2,450±-square-foot [sf]) ground-based fenced equipment compound situated at the rear(north) side of the Subject Property behind an existing boat storage warehouse.The equipment compound would include space for the equipment of multiple wireless service carriers (i.e.,Verizon Wireless, Dish Wireless and future carriers), and the Southold Fire District. The Verizon Wireless equipment would be installed atop a proposed 10±-foot-by-20±-foot(200±-sf) steel platform surrounded by a 42±-inch-high handrail, and would be covered by a steel canopy with a top height of 11-feet-6± inches agl. Four Verizon Wireless GPS units would be mounted atop the equipment canopy to a top height of 13-feet-6± inches agl. The Dish Wireless equipment would be installed atop a proposed 8±-foot-by-10±-foot(80±-sf) steel platform surrounded by a 42±-inch-high handrail. One Dish Wireless GPS unit would be mounted atop the equipment platform. The Southold Fire District equipment would be installed atop a proposed 8±-foot-by-10±-foot(80±-sf) equipment platform. The equipment within the compound would be connected to the concealment pole via cable bridges (one cable bridge per equipment platform).Additionally, utility connections(i.e., power and telco)would be routed underground from an existing utility pole on Main Road to a proposed transformer and mesa cabinet within the equipment compound. Power and telco conduits would be routed underground within the equipment compound from the transformer and mesa cabinet to the equipment platforms. All equipment within the compound would be elevated a minimum of 3± feet agl to provide a minimum of two feet of clearance above the base flood elevation of six feet(North American Vertical Datum of 1988). Proposed Wireless Communications Facility—Albertson Marine Part 1—Long Environmental Assessment Form The equipment compound would be surrounded by a 6±-foot agl black chain link fence with an access gate on the east side of the compound. Evergreen trees with a minimum height of 6± feet agl would be planted in a staggered pattern along the north and west sides of the compound to rovide additional screening. RECEIVED Page 1.Applicant/Sponsor Information: AUG The Co-Applicants for the proposed wireless communications facility are: 9 Z�z3 W. Zonis 3 Elite Towers, L.P. g Board of Appeals 1 South Durkee Lane East Patchogue, NY 11772 New York SMSA Limited Partnership d/b/a Verizon Wireless 4 Centerock Road West Nyack, NY 10994 Dish Wireless, LLC 5701 South Santa Fe Drive Littleton,CO 80120 Southold Fire District 55135 Main Road Southold, NY 10994 Page 1 Item B.Government Approvals: Agency Approval Town of Southold Planning Board Site Plan Approval, Special Exception,Waivers Town of Southold Building Department Building Permit, Floodplain Development Permit Town of Southold Board of Trustees Wetlands Permit,Waterfront Consistency Review Town of Southold Zoning Board of Appeals Variances New York State Department of Environmental Freshwater Wetlands Permit,Tidal Wetlands Letter of Conservation No Jurisdiction \\vhb.com\gbl\proj\Hauppauge\22175.00 Elite Towers-Albertson\Reports\SEQR\LEAF Attachment.doa 2 RECEIVED ."I Figure 1: Site location AUG 0 9 2023 vhb. Proposed Wireless Communications Facility - Albertson Marine 133 61405 Main Road, Hamlet of Southold, Town of Southold, Suffolk County, New ning Board of Appeals SCTM No.: District 1000—Section 056.00— Block 03.00— Lot 015.000 e mst'. Ik,-* ` Proposed Wireless • ��. Communications Facility ` ` W.j , •* . yam. , •. y 1.•�•. � is , TIP or Subject Property .0 04 �9 � a a Q Suffolk County 0 100 200 300 Feet 1 wVA 0 Subject Property* *Subject Property boundaries are approximate. Source.Suffolk County Real Property Tax Service Agency(2016),Neormop Imagery(2023) OFFICE LOCATION: MAILING ADDRESS: i Town Hall Annex ����SQ(/�y� P.O.Box 1179 54875 State Route 25 Southold,NY 11971 (cor.Main Rd.&Youngs Ave.) �® Telephone:631765-1938 Southold,NY 13 www.sontholdtownny.gov r��pUt RECEIVED AUG 0 9 2023 PLANNING BOARD OFFICE -7831 TOWN OF SOUTHOLD Zoning Board of Appeals MEMORANDUM To: Michael J. Verity, Chief Building Inspector Cc: Nancy Dwyer, Building Inspector Amanda Nunemaker, Building Permits Examiner Tracey Dwyer, Building Plans Examiner From: Heather M. Lanza, AICP, Planning Director Date: January 17, 2023 Re: New Wireless Communications Facility— Elite Towers 61405 Main Rd, Southold SCTM#1000-56-3-15 The application noted above requires review for a Notice of Disapproval. Please review for any non-conformities from the bulk schedule in the MII zoning district. It appears from our preliminary review that lot area and setback variances are required. Please also review lot coverage. Because federal law requires local municipalities to meet what is known as the "shot clock", we have very little turnaround time for this review. We would appreciate your response as soon as possible, and no later than January 23. We have enclosed the most recent plans for your review. They are also on Laserfiche at Planning/Applications/Site Plans/Pre-submission/56.-3-15 Cell Tower Facility @ Budds Pond/1000-56-3-15 Revised Plans Rec'd 1/10/23. We note and will advise the applicant that a permit from the Southold Town Trustees will also be required. Thank you for your cooperation. Encl.: Paper copy of the plans and cover letter from applicant 666 OLD COUNTRY ROAD, 9T"FLOOR AMATOGARDEN CITY,DAY 11530 LAIN G RCC U P, PL LC TEL:516.227.6363 1 FAX:516.22/.6367 RECEIVED AUG 0 9 2023 P eals January 9, 2023 Zoning Board of A p VIA ELECTRONIC Mill AND U.S. MAIL Town of Southold RECEIVED Planning Department Town Hall Annex Building JAN 10 2023 54375 Route 25 Southold Town PO Box 1179 Planning Board Southold,NY 11971 Attn.: Heather Lanza Re: Application(the"Application")to the Town of Southold("Town")by Elite Towers, L.P. ("Elite")in connection with the proposed public utility communication facility ("Communication Facility")to be located at 61405 Main Road,Southold,New York 11971 District 1000,Section 56 Block 3 Lot 15 (the"Property") Dear Ms.Lanza: In connection with the Application for the construction and maintenance of the Communication Facility on the Property,and in follow up to our correspondence dated December 5, 2022 ("December 5t'Correspondence"),herein is our summary of how we have addressed each of the comments from your email correspondence dated November 30,2022("11/30 Correspondence"). With the below summary,and provided materials(noted below),we believe that Elite has achieved completeness of the Application,allowing Elite to proceed with its submissions to the Town Board, Town Planning Board and Town Zoning Board of Appeals ("ZBA"). As we had done in our December 5'Correspondence,the comments from the 11/30 Correspondence are in italics,followed by responses to each. Upon your review,we respectfully request that you provide us the denial letter from the Town Building Department allowing us to file the respective board filings. The Town Code bulk schedule for the MH zone requires 80,000 sq.ft.per use.,The new wireless facility is considered a second use on the subjectproperty. The parcel is only about 41,000 sq.ft. in size where 160,000 sq.ft is required. This will require a substantial(74%)variance from the Town Zoning Board of Appeals. RESPONSE: The updated drawings sets,for Elite and DISH Wireless,both prepared by Azimuth Engineering P.C.,and attached with this submission(collectively,the"Drawings",individually the "Elite Drawings"or"DISH Drawings"),have addressed this request. Specifically,on Sheet Z-03 of the Elite Drawings and Sheet A-1B of the DISH Drawings,within the Bulk Requirements table,the requested variance has been included. 405 LEXINGTON AVENUE I CHRYSLER BUILDING,26T"FLOOR I NEW YORK,NY 10174 1 212.485.6000 402 MAIN STREET I SUITE 204 1 METUCHEN,NJ 08840 1 732.317.1511 RECEIVED 23ZopIalsThis proposed construction also exceeds the lot coverage maximum in the b RESPONSE:.As this request was already noted on the Drawings,no further update has been added. Does the plan show the distance to the rear property line?Does it meet the setback requirement for a rear yard for a principle use in the MII zoning district? We need the dimensions shown on the plan for the distance to the rear property line of the tower and the equipment cabinets to make the application complete.And if too close, a variance would be needed. RESPONSE: Sheets Z-02 and Z-08 of the Elite Drawings,and Sheets A-lA and A-1 C of the DISH Drawings, have been updated to more clearly depict the rear property line, allowing for the dimensions to the tower and equipment area to be shown as well.The tables on Sheets Z-03 and A- 1B,respectively,have been modified to reflect the new distances to the rear property line,as well.as the request for a variance from the rear yard setback requirement. In order for this application to proceed you would need variances to be approved by the Town Zoning Board of Appeals (ZBA). RESPONSE: As noted in our December 5'Correspondence,application will be made to the ZBA, when directed by the Town's Building Department. I also noted that the proposed construction appears to be within 100'of wetlands,.meaningyou will need the Town Trustees to review this proposal as well as Town Planning. Once the application is complete and you file for the variances with ZBA, site plan and special exception at Planning,you can file simultaneously with Trustees. To make the application complete,you will need a plan that shows the distance to the wetlands. RESPONSE: The Elite Drawings have been updated at Sheet Z-06, to depict a distance of approximately 80'to the waterbody to the north. As such,Elite will file for Town Trustee review in connection with this proposed condition. The plans shows a tower with `existing'Verizon antennas and `proposed'DISHantennas.Since the tower doesn't existyet, wouldn't it make sense that both carriers'antennas are proposed'? Or is DISH not yet on board with this application? RESPONSE: The DISH Drawings have been revised to indicate all proposed improvements, whether by Elite or DISH, as "Proposed",to eliminate this confusion. 1 don't see a plan that clearly labels the distance from the proposed pole to the nearest RR tracks. This needs to be submitted to make the application complete. RESPONSE: Sheet Z-02 of the Elite Drawings and Sheet A-lA of the DISH Drawings have been revised to include the distance from the railroad tracks to the proposed pole(approximately 48'). 2 RECEIVED �---- - AUG 0 9 2Upals 0023 01 Zoning BoardI The proposed screening vegetation is shown as crossing into the adjacent LIRR right of way property. The site must be designed to fit on the subject property, including the required screening vegetation. RESPONSE: The design has been updated on the Drawings,particularly Sheets Z-02 and A-lA, respectively, to shift the compound and proposed vegetation so that all proposed trees will be situated on the subject Property. Since this will require Special Exception approval by the Planning Board, as well as site plan approval,provide a narrative addressing 280-73 B. and C. items to make the application complete. RESPONSE: Attached to this submission is a Narrative which summarizes Elite's initial responses to the cited Code sections. Ifyou are requesting any waivers from the Planning Board(280-76.2), which I believe at least one (tower height over 80) is being requested, address those in a narrative to the Board in your application as well to make the application complete. RESPONSE: Attached to this submission is a Narrative which summarizes Elite's initial responses to the cited Code section. The storage building on which this site is proposed was constructed prior to site plan approval being required. This proposal may present issues for the landowner because they have historically used the area where the cell tower is proposed to store boats. Where will those boats be stored once the facility is constructed? RESPONSE: In consultation with the landlord, there has been a steady decline in boat storage demand,resulting in the availability of the area proposed for the Communication Facility. As such, there will be no issues in the installation of the Communication Facility on the Property,as there will remain sufficient space for any requested storage of boats. Finally, evidence to prove the need for the height will need to be presented. RESPONSE: As discussed,and in addition to the resubmission to the Town of November 4,2022, which included RF Reports from both DISH and Verizon Wireless in support of the need for the height, attached to this submission is a letter from Integrated Wireless Technologies, LLC, RF consultants for the Southold Fire District,along with accompanying mapping,confirming the need for the proposed height of the Communication Facility. The foregoing, together with"the issues identified in CityScape's initial incompleteness report, will need to be addressed before this application can be deemed complete. RESPONSE: As discussed,the submission of the foregoing items, upon acceptance,will resolve 3 RECEIVED the completeness process. AUG 0 9 2023 Shot Clock -3'3 63 Zoning Board of Appeals As noted within our December 5h Correspondence,with this submission,our unuorsumuing is that the shot clock recommences, and will run until the release of a Building Department letter outlining the required relief needed for the approval(or further comments related to the foregoing requests). If you should have any questions or require anything further,please feel free to contact me. Thank you for your continuing attention to this Application. Very truly yours, Gregory R. Alvarez Enclosures cc: Elite(via email, w/out enclosures) Verizon Wireless (via email,w/out enclosures) DISH(via email, w/out enclosures) 4 RECEIVED AUG 0/�9 2023 1� 31 Appeals Zoning Board of App ELITE TOWERS, L. P. 61405 Main Road Southold, New York NARRATIVE TO OUTLINE REQUESTED RELIEF AND TO ADDRESS CERTAIN TOWN OF SOUTROLD CODE SECTIONS Anticipated Relief As an initial matter, and prior to discussing the below Code requirements in greater detail, herein is the anticipated list of relief that Elite will need to seek as part of its Application: • Special Exception • Area Variance—Lot Size—for Two Uses • Area Variance—Rear Yard Setback • Area Variance—Fall Zone • Area Variance/Waiver—Height • Area Variance/Waiver—Distance to Residential Property Lines/Streets Sections from Code to Address Below are narrative responses to certain applicable provisions within the Town of Southold Code, which were requested to be addressed. The cited section is in italics, with the Responses below each one. §280-73 B. and C. B. Standards.In addition to the standards in Article XXU of this chapter, no special exception approval shall be granted unless the Planning Board specifically finds and determines the folloi,ving: (1) Construction of the proposed.facility or modification of the existing facility is a public necessity, in that it is required to meet current or expected demands of the telecommunications provider and to render adequate service to the public. RESPONSE: As set forth in the provided RF Reports and accompanying materials provided by DISH Wireless, Verizon Wireless and the Southold Fire District, each 1 A M P Arch i to ct u re Address:10200 Main Road,Unit 3A;Mattituck NY 11952 Phone:(516)214-0160 Design + Build August 1,2023 AUG 0 9 2023 Wetlands Permit Application :� 3 Cifarelli Residence Zoning Boar�of�ppeals 2672 Peconic Bay BLVD Laurel, N.Y. 11948 S CTM: 1000-128-06-13.3 Project Description: Previously Approved under Permit#10078 Dated February 16,2022;all to remain as part of this amendment Demolition of Existing 2 story Single Family Residence with Full Basement: Existing Basement and first floor structural members to remain: 1,850 S.F. Existing First Floor to be removed and rebuilt: 1,850 S.F. Proposed Addition to First Floor: 9.4'X2.0' 19 S.F. 17.0'x34.0' 545 S.F. 6.3'X11.5' 72 S.F. 3.4'x11.5' 39 S.F. 4.0'x16.3' 66 S.F. Addition Total:741 S.F. Proposed Stone Patio @ Grade(<8") 15'X34'-7" 519 S.F. Existing Second Floor and Roof to be removed: 1,140 S.F. Proposed Second Floor:27.7'X59.2' (1,575 S.F.) Proposed Second Story Deck: 18.5'X31.1' (387 S.F.) Proposed Exterior Staircase to Second Story Deck attached to side of home Proposed Concrete Stairwell to Basement from Exterior (2) Existing Sheds to be removed Existing Masonry Patio @ Grade to be removed New IA OWTS—Existing traditional system to be abandoned and/or removed New Buried Drywells: (2)8'Widex5' Deep Drywells; (1) 8'WideX2' Depp Drywell As-Built Firepit: 2.8'X9.8' (27 S.F.) As-Built Wood Deck @ Grade:5.9'X27.1' (155 S.F.) As-Built Hot Tub:3.1'X6.1' (19 S.F.) As-Built Pervious Stone Walls (2):1.7'X8.9' (15 S.F.) Each As-Built Flagpole&Stone Wall JOZEMCB-01 PCONWAY ACOROA CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) `..� 8/9/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME CT Pamela Conway Lupton 8 Luce,Inc. PHFAX 631 727-7138 225 Howell Ave acONE,No,Ext:(631)727-4114 244 A/c,No):( ) Riverhead,NY 11901 E-MAIL SS :Pam@luptonandluce.com INSURERS AFFORDING COVERAGE NAIC# INSURER A:Northfield Insurance Company INSURED INSURER B:Republic Franklin Insurance Company 12475 Jozefa McBurnie DBA McBurnie Tent Rentals INSURER C: PO BOX 767 INSURER D: Cutchogue,NY 11935 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER POLICY EFF POLICY EXP LIMITS LT INSD WVD DD MM DD A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000'000 CLAIMS-MADE X OCCUR WS556581 8/12/2023 8/12/2024 DAMAGE TO RENTED 100,000 X PREMISES Ea occurrence $ MED EXP(Any oneperson) $ 5,000 PERSONAL&ADV INJURY $ 1'000'600 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY PEC LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: I$ B AUTOMOBILE LIABILITY i CO agpINEDt)INGLE LIMIT $ 500,000 ANY AUTO 4531740 5/26/2023 5/26/2024 BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY X AUTOS BODILY INJURY Per accident $ X AUTOS ONLY X NON ONLY PeracadentDAMAGE $ $ UMBRELLA LIAR j I OCCUR EACH OCCURRENCE $ EXCESS LIAR ri CLAIMS-MADE AGGREGATE $ DED RETENTION$ Is PER WORKERS COMPENSATION TA UTE EERH AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE J E.L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ i DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Certificate holder included as Additional Insured per the provisions of attached form#CG2012 05/09. AUG ® 9 2023 Board of j zoning peals CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town Route h ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179 Southold,NY 11971 AUTHORIZED ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD POLICY NUMBER:WS5rJ6rJ81 COMMERCIAL GENERAL LIABILITY CG 20 12 05 09 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - STATE OR GOVERNMENTAL AGENCY OR SUBDIVISION OR POLITICAL SUBDIVISION - PERMITS OR AUTHORIZA 7Zoning ]APpeals This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART SCHEDULE State Or Governmental Agency or Subdivision or Political Subdivision: Town of Southold, 53095 Route 25, PO Box 1179, Southold, NY 11971 Information required to complete this Schedule,if not shown above,will be shown in the Declarations. Section 11 -Who Is An Insured is amended to include as 2. This insurance does not apply to: an Insured any state or governmental agency or subdivision or political subdivision shown in the Schedule, a. "Bodily injury","property damage"or"personal and subject to the following provisions: advertising injury" arising out of operations performed for the federal government, state or 1. This insurance applies only with respect to operations municipality;or performed by you or on your behalf for which the state or governmental agency or subdivision or political b. "Bodily injury"or"property damage"included within subdivision has issued a permit or authorization. the"products-completed operations hazard". CG 20 12 05 09 Copyright,Insurance Services Office,Inc.,2008 Page 1 of 1 y� JOZEMCB-01 PCONWAY ACORO' CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DDIYYYY) `.� 8/9/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Pamela Conway NAME: Lupton&Luce,Inc. PHONE 631 727-4114 244 FAX 225 Howell Ave A/c,No,Et):( ) (AIC,No):(631)727-7138 Riverhead,NY 11901 Al D ESS:Pam@luptonandluce.com INSURER(SJ AFFORDING COVERAGE NAIC# INSURERA:Northfield Insurance Company INSURED INSURER B:Republic Franklin Insurance Company 12475 Jozefa McBurnie DBA McBurnie Tent Rentals INSURERC: PO Box 767 INSURER D: Cutchogue,NY 11935 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LT INSD WVD MM DD MM D A I X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADEX OCCURWS556581 8/12/2023 8/12/2024 DAMAGE TO RENTED 100,000 X PREMISES Ea occurrence $ MED EXP(Any oneperson) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY F--]jE 0 D LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: _1$ B AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 500,000 (Ea_acside ANY AUTO 4531740 5/26/2023 5/26/2024 BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY X AUTOS I BODILY INJURY Per accident $ X AUTOS ONLY X ABIOS ONLY PROPERTY DAMAGE Per accident $ UMBRELLA LIABI OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED I RETENTION$ $ WORKERS COMPENSATION AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY FlCER/M IETOR EXCLUDED ECUTIVE D NIA E.L.EACH ACCIDENT $ (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Certificate holder included as Additional Insured per the provisions of attached form#CG2012 05/09. AUG 0 9 2023 -733g Zoning Board of Appeals CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Townof Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Route h ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179 Southold,NY 11971 AUTHORIZED 1? %��_ ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD r' I POLICY NUMBER:WSrJrJ6rJ81 COMMERCIAL GENERAL.LIABILITY CG 20 12 05 09 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - STATE OR GOVERNMENTAL AGENCY OR SUBDIVISION OR POLITICAL SUBDIVISION - PERMITS OR AUTHORIZATIO RECEIVED This endorsement modifies insurance provided under the following: o 223 COMMERCIAL GENERAL LIABILITY COVERAGE PART AUG 31 als SCHEDULE Zonials ng Board of St Or Governmental Agency or Subdivision or Political Subdivision: Town of Southold, 53095 Route 25, PO Box 1179, Southold, NY 11971 Information required to complete this Schedule,if not shown above,will be shown in the Declarations. Section 11-Who Is An Insured is amended to include as 2. This insurance does not apply to: an Insured any state or governmental agency or subdivision or political subdivision shown in the Schedule, a. "Bodily injury","property damage"or"personal and subject to the following provisions: advertising injury" arising out of operations performed for the federal government, state or 1. This insurance applies only with respect to operations municipality;or performed by you or on your behalf for which the state or governmental agency or subdivision or political b. "Bodily injury"or"property damage"Included within subdivision has issued a permit or authorization. the"products-completed operations hazard". CG 20 12 05 09 - Copyright,Insurance Services Office,Inc.,2008 Page i of 1 JOZEMCB-01 PCONWAY ACORO" CERTIFICATE OF LIABILITY INSURANCE DAT8/9/2 DIYYYY) 8/9/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed, If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Pamela Conway Lupton&Luce,Inc. PHONE 631 727-4114 244 ac,No: 631 727-7138 225 Howell Ave A/C,No,Et):( ) ( ) Riverhead,NY 11901 ADDARESS:Pam@luptonandluce.com INSURERS AFFORDING COVERAGE NAIC# INSURER A:Northfield Insurance Company INSURED INSURER B:Republic Franklin Insurance Company 12475 Jozefa McBurnie DBA McBurnie Tent Rentals INSURER C: PO BOX 767 INSURER D: Cutchogue,NY 11935 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. (NSR TYPE OF INSURANCE IN DL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR I D WVD M D M DMM A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCURWS556581 8/12/2023 8/12/2024 DAMAGE TO RENTED 100,000 X PREMISES Ea occurrence $ MED EXP(Any oneperson) $ 5'000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000'000 PRO- 2,000,000 X POLICY JECT LOC PRODUCTS-COMP/OP AGG $ OTHER: I $ B AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 500,000 (Ea_a c;icLe111) $ ANY AUTO 4531740 5/26/2023 5/26/2024 BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY X AUTOS BODILY INJURY Per accident $ X AUTOS ONLY X AUTOS ONLY Perr accident AMAGE $ UMBRELLA LLAB ( OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION PERI I H AND EMPLOYERS'LIABILITY Y/N STATUTE �E _LR ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached If more space is required Certificate holder included as Additional Insured per the provisions of attached form#CG2012 05/09. Fzoning EIVED 0gq9NZ3 U 3�Weals ard ofApp CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town Route h ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179 Southold,NY 11971 AUTHORIZED REPRESENTATIVE R ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD POLICY NUMBER: WS556581 COMMERCIAL GENERAL LIABILITY CG 20 12 05 09 THIS ENDORSEMENT CHANGES,THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - STATE OR GOVERNMENTAL AGENCY OR SUBDIVISION OR POLITICAL SUBDIVISION - PERMITS OR AUTHORI EIVED This endorsement modifies insurance provided under the following: AUG U 9 2023 COMMERCIAL GENERAL LIABILITY COVERAGE PART �<63� Zoning Board of Appeals SCHEDULE State Or Governmental Agency or Subdivision or Political Subdivision: Town of Southold, 53095 Route 25, PO Box 1179, Southold, NY 11971 Information required to complete this Schedule,if not shown above,will be shown in the Declarations. Section 11-Who Is An Insured is amended to include as 2. This insurance does not apply to: an Insured any state or governmental agency or subdivision or political subdivision shown in the Schedule, a. "Bodily injury","property damage"or"personal and subject to the following provisions: advertising injury" arising out of operations performed for the federal government, state or 1. This insurance applies only with respect to operations municipality;or performed by you or on your behalf for which the state or governmental agency or subdivision or political b. "Bodily injury"or"property damage"included within subdivision has issued a permit or authorization. the"products-completed operations hazard". CG 20 12 05 09 Copyright,Insurance Services Office,Inc.,2008 Page 1 of 1 JOZEMCB-01 PCONWAY ACORO' CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 8/9/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Pamela Conway NAME: Lupton&Luce,Inc. PHONE 225 Howell Ave (A/c,No,Ext):(631)727-4114 244 AIC,N.):(631)727-7138 Riverhead,NY 11901 E-MAIL Pam@luptonandluce.com INSURERS AFFORDING COVERAGE NAIC# INSURER A:Northfield Insurance Company INSURED INSURER B:Republic Franklin Insurance Company 12475 Jozefa McBurnie DBA McBurnie Tent Rentals INSURER C: PO Box 767 INSURER D: Cutchogue,NY 11935 INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS T INS. WVD M DD M D A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCURWS556581 8/12/2023 8/12/2024 DAMAGE TO RENTED 100,000 X PREMISES Ea occurrence $ MED EXP(Any oneperson) $ 5,000 PERSONAL$ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000'OOO X POLICY❑JE� LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ B AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 500,000 aacciden( $ ANY AUTO j 14531740 5/26/2023 5/26/2024 BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY X AUTOS BODILY INJURY Per accident $ X HIRED X NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY Per accident $ IS UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE Is DED I I RETENTION$ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE I I ER ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ E.L.EACH ACCIDENT 1 $ OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ yes,describe under DE.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS below I DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required Certificate holder included as Additional Insured per the provisions of attached form#CG2012 05/09. FIF- AUG cEIVED 20233 A eatsBoard of pP CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town Route h ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179 Southold,NY 11971 AUTHORIZED A47 ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD POLICY NUMBER: WS556581 COMMERCIAL GENERAL LIABILITY CG 20 12 05 09 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - STATE OR GOVERNMENTAL AGENCY OR SUBDIVISION OR POLITICAL SUBDIVISION - PERMITS OR AUTHORIZATIONS RECEIVED This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART AUG 0 9 208 SCHEDULE �� eals in Board �fApp State Or Governmental Agency or Subdivision or Political Subdivision: Town of Southold, 53095 Route 25, PO Box 1179, Southold, NY 11971 Information required to complete this Schedule,if not shown above,will be shown in the Declarations. Section 11 -Who Is An Insured is amended to include as 2. This insurance does not apply to: an Insured any state or governmental agency or subdivision or political subdivision shown in the Schedule, a. "Bodily injury","property damage"or"personal and subject to the following provisions: advertising injury" arising out of operations performed for the federal government, state or 1. This insurance applies only with respect to operations municipality;or performed by you or on your behalf for which the state or governmental agency or subdivision or political b. "Bodily injury"or"property damage"Included within subdivision has issued a permit or authorization. the"products-completed operations hazard". CG 20 12 05 09 Copyright,Insurance Services Office,Inc.,2008 Page 1 of 1 RECEIVED AGRICULTURAL DATA STATEMENT AUG 312023 ZONING BOARD OF APPEALS TOWN OF SOUTHOLD3 Zoning Board of Appals WHEN TO USE THIS FORM: This form must be completed by the applican or -try-spee�i-al-u permit, site plan approval, use variance, area variance or subdivision approval on property within an agricultural district OR within 500 feet of a farm operation located in an agricultural district. All applications requiring an agricultural data statement must be referred to the Suffolk County Department of Planning in accordance with Section 239m and 239n of the General Municipal Law. 1. Name of Applicant: Elite Towers, LP 2. Address of Applicant: 1 South Durkee Lane, East Patchogue, NY 11772 3. Name of Land Owner(if other than Applicant): Budd's Pond Marina, Inc. 4. Address of Land Owner: 61405 Main Road, Southold, NY 11971 5. Description of Proposed Project: construct and maintain a new public utility wireless communications facility 6. Location of Property: (road and Tax map number) 61405 Main Road, Southold, NY SCTM # 1000-56-3-15 7. Is the parcel within 500 feet of a farm operation? { } Yes {)� No 8. Is this parcel actively farmed? { } Yes { } No 9. Name and addresses of any owner(s) of land within the agricultural district containing active farm operations. Suffolk County Tax Lot numbers will be provided to you by the Zoning Board Staff, it is your responsibility to obtain the current names and mailing addresses from the Town Assessor's Office (765-1937) or from the Real Property Tax Office located in Riverhead. NAME and ADDRESS 1. SCTM#: 1000-56-1-11.11, Owner:Angela Norton, Mailing Address: 610 Pond Ave, Southold, NY 11971 2. SCTM#: 1000-56-1-11.12, Owner:Angela Norton, Mailing Address: 610 Pond Ave Southold, NY 11971 3. SCTM#: 1000-56-3-13.3, Owner:Angela Norton, Mailing Address: 610 Pond Ave Southold, NY 11971 4. 5. 6. (Please use the back of this page if there are additional property owners) Elit�,;Towers, LP 05 /15 /2023 Signatur. of Applicant By: Tanya Negron, Managing Member Date Note: 1. The local Board will solicit comments from the owners of land identified above in order to consider the effect of the proposed action on their farm operation. Solicitations will be made by supplying a copy of this statement. 2. Comments returned to the local Board will be taken into consideration as part as the overall review of this application. 3. Copies of the completed Agricultural Data Statement shall be sent by applicant to the property owners identified above. The cost for mailing shall be paid by the Applicant at the time the application is submitted for review. i t b Board of Zoning Appeals ApplicationFRECEIV7ED AUTHORIZATION �Boarcd (Where the Applicant is not the Owner) Zoni �t on behalf of Budd's 1, Pond Marina, Inc. residing at 61405 Main Road, (Print property owner's name) (Mailing Address) Southold, NY 11971 do hereby authorize Southold Fire District, as Co-Applicant (Agent) to apply for variance(s) on my behalf from the Southold Zoning Board of Appeals. Budd's Pond Marina, Inc. Owner's Signature) i I I f "-A Iq (�j •f�� (Print Owner's Name) R�C�T�9�D Board of Zoning Appeals Application AU/G�� 9 2023 I �3 eals Zoning AUTHORIZATION Board o ApP (Where the Applicant is not the Owner) on behalf of Budd's IPond Marina, Inc. residing at 61405 Main Road, (Print property owner's name) (Mailing Address) Southold, NY 11971 do hereby authorize DISH Wireless LLC, as Co-Applicant (Agent) to apply for variance(s)on my behalf from the Southold Zoning Board of Appeals. Budd's Pond Marina, Inc. (Owner's Signature) (Print Owner's Name) Town of Southold RECEIVED LWRP CONSISTENCY ASSESSMENT FO AUG 0 9 2023 A. INSTRUCTIONS I � �Jfppeals Zoning B and 1. All applicants for permits* including Town of Southold agencie for proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law. This assessment is intended to supplement other information used by a Town of Southold agency in making a determination of consistency. *Except minor exempt actions including Building Permits and other ministerial permits not located within the Coastal Erosion Hazard Area. 2. Before answering the questions in Section C, the preparer of this form. should review the exempt minor action list, policies and explanations of each policy contained in the Town of Southold Local Waterfront Revitalization Program. Ai proposed' action. will be evaluated. as to its si �ilk ficarif benefitk&and-adverse effects upon the coastal:drea(which.includes All,:of,S.outhold Town). 1 If any question in Section C on this form is answered "yes" or "no", then the proposed action will affect the achievement of the LWRP policy standards and conditions contained in the consistency review law. Thug, :each answer inust:be explained in detail,..listiii? both supporting and non-. suoportine-facts. If an action cannot be certified as consistent with the LWRP policy standards and conditions,`it:shall not be'.undertaken. A copy of the LWRP is available in the following places: online at the Town of Southold's website (southoldtown.northfork.net), the Board of Trustees Office, the Planning Department, all local libraries and the Town Clerk's office. B. DESCRIPTION OF SITE AND PROPOSED ACTION SCTM## 056.00 ;.03.00 :,015.000 PROJECT NAME Proposed Wireless Communications Facility-Albertson Marine The Application has been submitted to (check appropriate response): Town Board ❑ Planning Board❑✓ Building Dept. ❑✓ Board of Trustees ❑✓ 1. Category of Town of Southold agency action(check appropriate response): (a) Action undertaken directly by Town agency(e.g. capital ❑ construction,planning activity, agency regulation, land transaction) ❑ (b) Financial assistance(e.g.grant,loan,subsidy) (c) Permit, approval, license,certification: Nature and extent of action: ..See Attachment__ P Location Of action: 61405 Main Road, hamlet of Southold (SCTM:0100-056.00-03.00-015.000) Site acreage: 0.95±-acre Subject Property/0.06±-acre facility compound (Project Are ) RECEIVE® 4 9 202�33� Present land use: Boat storage and maintenance AUG Present zoning classification:.—Marine II (MII) Zoning Board of APPea's 2. If an application for the proposed action has been filed with the Town of Southold agency, the following information shall be provided: Elite Towers,LP;New York SMSA Limited Partnership d/b/a Verizon Wireless;Dish Wireless,LLC; Southold Fire District (a) Name of applicant: _ (b) Mailing address: c/o Gregory R.Alvarez, Esq.,Amato Law Group, PLLC 666 Old Country Road, Suite 901, Garden City, NY 11530 c Telephone number: 516-227-6363 _ Will the action be directly undertaken,require funding,or approval by a state or federal agency? Yes ❑ Nov If yes, which state or federal agency? C. Evaluate the project to the following policies by analyzing how the project will further support or not support the policies. Provide all proposed Best Management Practices that will further each policy. Incomplete answers will require that the form be returned for completion. DEVELOPEWCOAST POLICY Policy 1. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and minimizes adverse effects of development. See LWRP Section III–Policies; Page 2 for evaluation criteria. i , a Yes ❑ No ❑ Not Applicable See Attachment I Attach additional sheets if necessary Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See LWRP Section III–Policies Pages 3 through 6 for evaluation criteria 0 Yes ❑ No ❑ Not Applicable See Attachment RECEIVED Attach additional sheets if necessary AUG 0 9 2023 Policy 3. Enhance visual quality and protect scenic resources lg9j?Q%,gt#sffqowp3 ado Southold. See LWRP Section III—Policies Pages 6 through 7 for evaluation crit ❑✓ Yes ❑ No ❑ Not Applicable See'Attachment Attach additional sheets if necessary NATURAL COAST POLICIES Policy 4. Minimize loss of life, structures, and natural resources from flooding and erosion. See LWRP Section III—Policies Pages 8 through 16 for evaluation criteria Z. Yes ❑ No ❑ Not Applicable See Attachment i Attach additional sheets if necessary ..._............ Policy 5. Protect and improve water quality and supply in the Town of,Southold. See LWRP Section III — Policies Pages 16 through 21 for evaluation criteria ❑ Yes ❑ No ❑✓ Not Applicable As the Proposed Facility would be unmanned,it would not require potable water,nor would any liquid waste be generated.Furthermore,the Proposed Facility would be located within an existing developed area and no new impervious.surfaces resulting in additional volumes of stormwater, runoff would be created. Rather,it is expected that installation of the Proposed Facility would result in a net 0.04±-acre reduction of impervious surfaces and a corresponding increase in landscaped areas(i.e.,for screening vegetation to surround the proposed equipment compound)._Thus,there would be no impacts to water quality or supply. Attach additional sheets if necessary Policy 6. Protect and restore the quality and function of the Town of Southold ecosystems including Significant Coastal Fish and Wildlife Habitats and wetlands. See LWRP Section III—Policies; Pages 22 through 32 for evaluation criteria. ❑✓ Yes [—]No ❑ Not Applicable See Attachment 9 ca o a1s o�1r9 Attach additional sheets if necessary Policy 7. Protect and improve air quality in the Town of Southold. See LWRP Section III — Policies Pages 32 through 34 for evaluation criteria. ❑ Yes ❑No❑✓ Not Applicable As the Proposed Facility would be unmanned and remotely monitored, requiring minimal vehicular trips(i.e.,approximately one per carrier per month for maintenance/monitoring),there would be no significant adverse impacts to air quality resulting from automobile emissions.Moreover,the Proposed Facility does not involve the creation of an industrial use.As such,it is not anticipated that the Proposed Facility would have any adverse impabts to air quality in the Town of Southold. Attach additional sheets if necessary - Policy 8. Minimize environmental degradation in Town of Southold from solid waste and hazardous substances and wastes. See LWRP Section III—Policies; Pages 34 through 38 for evaluation criteria. ❑Yes 1:1 No ❑✓ Not Applicable The Proposed Facility involves the construction of an unmanned communications facility,which would generate minimal construction solid waste and no solid waste during operations.Thus,no environmental degradation from generation of solid waste,hazardous substances or other wastes would occur. PUBLIC COAST POLICIES Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public resources of the Town of Southold. See LWRP Section III—Policies; Pages 38 through 46 for evaluation criteria. ❑ Ye❑ No❑✓ Not Applicable As previously indicated,the Proposed Facility involves the construction of a wireless communications facility upon a previously disturbed portion of the overall Subject Property that is used as a boat storage and maintenance facility.As such,this project does not provide or impede public access to, or recreational use of,coastal waters, public lands and public resources. Attach additional sheets if necessary WORKING COAST POLICIES Policy 10. Protect Southold's water-dependent uses and promote siting of new water-dependent uses in suitable locations. See LWRP Section HI.—Policies; Pages 47 through 56 for evaluation criteria. Yes ❑ No ❑ Not Applicable See Attachment CEIV ED AUG zoning Board of App a s Attach additional sheets if necessary Policy 11. Promote sustainable use of living marine resources in Long Island Sound, the Peconic Estuary and Town waters. See LWRP Section III—Policies; Pages 57 through 62 for evaluation criteria. ❑Yes ❑ No 0 Not Applicable M the Proposed_Facility would be unmanned,is unrelated to marine resources,and is not located on or adjacent to the shoreline,it would not impact living marine resources. Attach additional sheets if necessary Policy 12. Protect agricultural lands in the Town of Southold. See LWRP Section III— Policies; Pages 62 through 65 for evaluation criteria. []Yes ❑ No 0 Not Applicable The proposed facility would have no impact on agricultural lands in the Town,as the proposed facility would be situated on a previously disturbed,unvegetated area of a boat storage and maintenance facility. Attach additional sheets if necessary Policy 13. Promote appropriate use and development of energy and mineral resources. See LWRP Section III—Policies; Pages 65 through 68 for evaluation criteria. ❑✓ Yes ❑ No ❑ Not Applicable See Attachment ALPREPARED BY TITLE Environmental Planner DATE June 7,2023 William Sklar,AICP VHB Engineering,Surveying,Landscape Architecture and Geology,P.C., as Environmental Consultant to the Co-Applicants Pro`,.;Oed Wireless Communications Facility- :..::hrtson Marine 61405 Main Road Hamlet of Southold,Town of Southold Suffolk County, New York R F CEl\/]D LWRP Consistency Assessment Form AUG ® 9 2023 Attachment eals Zoning Boar of App , Nature and Extent of Action: The Proposed Action involves the installation of a wireless communications facility, including a concealment pole and associated equipment, at 61405 Main Road in the hamlet of Southold,Town of Southold, Suffolk County, New York(the "Subject Property," see attached Site Location map). Specifically, the Proposed Action includes the installation of a 150±-foot above grade level (agl) concealment pole with the antennas of multiple wireless service carriers concealed within and two Southold Fire District whip antennas mounted atop the concealment pole reaching a top height of 164-feet-10±-inches agl. Six Verizon Wireless panel antennas would be installed within the concealment pole in three sectors (two panel antennas per sector) at centerline heights of 141-feet-2± inches agl and 146-feet-1± inch agl.Three Dish Wireless panel antennas would be installed within the concealment pole in three sectors (one panel antenna per sector) at a centerline height of 132± feet agl.There would be room for additional future wireless service carrier antennas within the concealment pole below the Verizon Wireless and Dish Wireless antennas. The concealment pole would be installed within a 70±-foot-by-35±-foot(2,450±-square-foot [sf]) ground-based fenced equipment compound situated at the rear(north) side of the Subject Property behind an existing boat storage warehouse.The equipment compound would include space for the equipment of multiple wireless service carriers (i.e.,Verizon Wireless, Dish Wireless and future carriers), and the Southold Fire District. The Verizon Wireless equipment would be installed atop a proposed 10±-foot-by-20±-foot(200±-sf) steel platform surrounded by a 42±-inch-high handrail, and would be covered by a steel canopy with a top height of 11-feet-6± inches agl. Four Verizon Wireless GPS units would be mounted atop the equipment canopy to a top height of 13-feet-6± inches agl. The Dish Wireless equipment would be installed atop a proposed 8±-foot-by-10±-foot (80±-sf) steel platform surrounded by a 42±-inch-high handrail. One Dish Wireless GPS unit would be mounted atop the equipment platform. The Southold Fire District equipment would be installed atop a proposed 8±-foot-by-10±-foot (80±-sf) equipment platform. The equipment within the compound would be connected to the concealment pole via cable bridges (one cable bridge per equipment platform).Additionally, utility connections (i.e., power and telco)would be routed underground from an existing utility pole on Main Road to a proposed transformer and mesa cabinet within the equipment compound. Power and telco conduits would be routed underground within the equipment compound from the transformer and mesa cabinet to the equipment platforms. All equipment within the compound would be elevated a minimum of 3± feet agl to provide a minimum of two feet of clearance above the base flood elevation of six'feet(North American Vertical Datum of 1988). RECEIVED Proposed Wireless Communic; . > is Facility—Albertson Marine AUG 0 9 2023 LWRP Consistency Assessment Form .16 3') The equipment compound would be surrounded by a 6±-foot agl black chain linkofent� e6witli an accessAppe _ gate on the east side of the compound. Evergreen trees with a minimum height of 6± feet agl would be planted in a stager pattern along the north and west sides of the compound to provide additional screening. Section C—Evaluation of LWRP Policies This section provides additional discussion of the relevant items listed in Section C of the LWRP - Consistency Assessment Form. Policy 1 —Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location,and minimizes adverse effects of development. The proposed concealment pole and associated equipment compound would be situated upon an unvegetated portion of the overall Subject Property,which currently serves as a boat storage and maintenance facility.The Project Area would occupy only 0.06± acre (5.9± percent of the Subject Property).The proposed concealment pole would conceal the antennas of multiple wireless service carriers within the pole,thereby promoting co-location and obviating the need for multiple tall structures throughout the community, and would be a neutral color to blend with the sky and surroundings.The installation of Southold Fire District communications antennas would improve emergency response services in the area. Further, the concealment pole would be situated along a corridor containing a variety of uses, including marinas and the Long Island Rail Road (LIRR), rather than along the shoreline or on agricultural or open space land. Finally,the presence of a communications facility along (or visible from) the Main Road (NYS Route 25) corridor would not be precedent setting, as there are other similar facilities with communications antennas along that roadway, including at the Southold Fire Department, 1.16± miles west of the Proposed Facility, and at the Southold Police Department, 3.64± miles southwest of the Proposed Facility.Overall,the design and location of the Proposed Facility minimizes adverse effects of development and is consistent with this Policy. Policy 2—Protect and preserve historic and archaeological resources of the Town of Southold. Section 106 review was completed for the Proposed Facility.The New York State Historic Preservation Office (NYSHPO) issued a determination as part of the Section 106 review, dated November 16, 2017, indicating "No Historic Properties in Area of Potential Effects (APE)"for Direct Effects, and "No Adverse Effect on Historic Properties in APE"for Visual Effects (see Appendix A for SHPO determination). Therefore,the Proposed Facility is consistent with this Policy. Policy 3—Enhance visual quality and protect scenic resources throughout the Town of Southold. Although the proposed concealment pole would be visible from the surrounding area, including along Main Road (a designated Scenic Byway), it is anticipated, as indicated by the visual analysis submitted under separate cover(see Planning,Zoning and Visual Impact Analysis,VHB May 2023) that views would be limited, as the proposed concealment would be obscured from view from many locations by intervening structures and vegetation.The proposed ground-based equipment compound would be situated at the rear of the overall Subject Property, behind an existing building, such that it would not be visually prominent in views from the surrounding area. Finally, wireless service carrier antennas for multiple carriers would be concealed within the concealment pole structure, screening the antennas from 2 RECFEIVSD Proposed Wireless Cor.:....inications Facility—Albertson Marine A�G 0 9 2023 LWRP Consistency Assessment Form 9of �rhnc� Boa dAppeals view and obviating the need for multiple communications facilities in the area.Additio 9, concealment pole's neutral coloration would allow it to blend with the surrounding area. Further,views of the proposed concealment pole would not be unprecedented, as there are other similar facilities with communications antennas along that roadway, including at the Southold Fire Department, 1.16± miles west of the Proposed Facility, and at the Southold Police Department, 3.64± miles southwest of the Proposed Facility. Overall,the Proposed Facility has been designed in a manner that is protective of visual quality and scenic resources, consistent with this Policy. Policy 4—Minimize loss of life,structures,and natural resources from flooding and erosion. The Subject Property is not located within a Coastal Erosion Hazard Area. According to the Federal Emergency Management Agency(FEMA) Flood Insurance Rate Map (FIRM) Panel 36103C0l59H,the Proposed Facility location is within a designated Special Flood Hazard Area (i.e., Zone AE, base flood elevation 6 feet).This indicates that there is a one percent annual chance of flood waters reaching or exceeding the base flood elevations at the Subject Property.As indicated by the project engineer,Azimuth Engineering, installation of the Proposed Facility would result in the minimal disturbance of only 0.08± acre of existing unvegetated, previously developed areas on the Subject Property and a 0.04±-acre reduction of impervious surfaces at the Subject Property, replacing existing impervious surfaces with new landscaping (i.e., screening vegetation surrounding the ground-based equipment compound). Furthermore,the Proposed Facility is designed to meet the Town's Floodplain Development Permit requirements for nonresidential structures, as set forth at§ 148-19(A) of the Town - Code.These design features include elevating the proposed equipment on platforms at least two feet above the base flood elevation, and ensuring that the portions of the facility below the base flood elevation (i.e.,the base of the concealment pole and equipment platform support piers)will be constructed to be watertight and substantially impermeable to the passage of water and are capable of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. Based on the design of the Proposed Facility, it is consistent with this Policy. Policy 6.— Protect and restore the quality and function of the Town of Southold ecosystems including Significant Coastal Fish and Wildlife Habitats and wetlands. The Project Area is not within or adjacent to a Significant Coastal Fish and Wildlife Habitat.The Project Area is within the 100-foot jurisdictional adjacent area of NYSDEC and Town of Southold regulated freshwater wetlands. Consultation is underway to secure wetlands permits from the NYSDEC and the Town.As provided by the project engineer, Azimuth Engineering, during construction, silt fence, straw bales, and other erosion and silt controls will be installed and maintained, as necessary, to prevent adverse impacts on wetlands. It is also noted that the Proposed Facility would be on a previously disturbed, unvegetated area, and would not result in any significant adverse impacts to ecosystems. Policy 10—Protect Southold's water-dependent uses and promote siting of new water-dependent uses in suitable locations. As the Proposed Facility is a wireless communications facility, it would not directly protect or promote the siting of water-dependent resources. However, existing and future water-dependent uses would potentially benefit in emergency situations, as Verizon Wireless service, Dish Wireless service, and the services of potential future wireless service providers that would co-locate within the facility, would be 3 Proposed Wireless Communications Facility-Albertson Marine AUG 0 9 2023 LWRP Consistency Assessment Form 3c� Zoning Board of Appeals enhanced. In addition,the Southold Fire Department would install commu of the concealment pole, thereby improving its emergency communications capabilities. Policy 13—Promote appropriate use and development of energy and mineral resources. The Proposed Facility would use a minimal amount of electricity and would be unmanned.Therefore,the effect on energy and mineral resources would be minimal. \\vhb.cam\gbl\proj\Hauppauge\22175.00 Elite Towers-Albertson\Reports\LWRP\CAF Attachment.dou 4 RECEIVED Figure 1: Site location AUG 0 9 •' hb. Proposed Wireless Communications Facility - Albertson Marine 2023 61405 Main Road, Hamlet of Southold, Town of Southold, Suffolk County, New knin ��3q 9 Board of Appeals SCTM No.: District 1000—Section 056.00— Block 03.00—Lot 015.000 t' •�� 7r � � sY. � �� yew ri '_. 01�. Proposed,Wireless t Communilcations Facility it OW IL R°ads` v� e 40 • ''; Subject Property pr +� •s r , � a °a cam 0 Suffolk County N 0 100 200 300 Feet Q Subject Property* *Subject Property boundaries are approximate. Source Suffolk County Real Property Tax Service Agency(2016),Nearmop Imagery(2023) RECEIVE® • AUG 0 9 2023 Appe' ndix A '�9 Zoning Board of p� eals New York State Historic Preservation Office Correspondence 1 Megan Ricks Gomez From: towernotifyinfo@fcc.gov Sent: Thursday, November 16, 2017 10:45 AM To: Megan Ricks Gomez Subject: Section 106 Notification of SHPO/THPO Concurrence- Email ID#r60 _ RECFIi0f Fp This is to notify you that the Lead SHPO/THPO has concurred with the following fili g: AUG 0 9023 Date of Action: 11/16/2017 Direct Effect: No Historic Properties in Area of Potential Effects (APE) Zoning Board Appeals Visual Effect: No Adverse Effect on Historic Properties in APE Comment Text: The NYSHPO concurs with the recommended effect finding. Reviewed by Christina Vagvolgyi, NYSHPO. r File Number: 0007963465 TCNS Number: 162082 Purpose: New Tower Submission Packet Notification Date: 7AM EST 10/19/2017 Applicant: Elite Towers, LP Consultant: EnviroBusiness Inc. d/b/a EBI Consulting (EBI#6117004802) Positive Train Control Filing Subject to Expedited Treatment Under Program Comment: No Site Name: Albertson Marine Site Address: 61405 Main Road Detailed Description of Project: 6117004802 Proposed construction of a new telecommunications monopole and compound resulting in ground disturbance Site Coordinates: 41-4-33.0 N, 72-24-22.2 W City: Southold County: SUFFOLK State:NY Lead SHPO/THPO: New York State Historic Preservation Office' NOTICE OF FRAUDULENT USE OF SYSTEM, ABUSE OF PASSWORD AND RELATED MISUSE Use of the Section 106 system is intended to facilitate consultation under Section 106 of the National Historic Preservation Act and may contain information that is confidential,privileged or otherwise protected from , disclosure under applicable laws. Any person having access to Section 106 information shall use it only for its intended purpose. Appropriate action will be taken with respect to any misuse of the system._ i RECEIVED APPLICANT'S AFFIDAVIT AUG 0 9 2023 J'�201 APPLICANT'S AFFIDAVIT Zoning Board of Appeals STATE OF NEW YORK COUNTY OF SUFFOLK Robert Czarni4van_--behalf of New York SMSA Limited Partnership d/b/a Verizon Wireless being duly sworn, deposes and says that he c/o Amato Law Group, P LC, 666 Old Country Rd., Ste. 901 resides at Garden City NY 11530 in the State of New York, and that he is the owner of property located at 61405 Main Road, Southold, NY , SCTM# 1000-56-3-15 or that he is the of the Partnership (Title) (Specify whether Partnership or Corp.) Budd's Pond Marina, Inc. authorizing a and MMMA11M is the owner of the above property, which is hereby YXO#X Site Plan application; that there are not existing structures or improvements on the land which are not shown on the Site Plan; that the title to the entire parcel, including all rights-of-way, has been clearly established and is shown on said Plan; that no part of the Plan infringes upon any duly filed plan which has not been abandoned both as to lots and as to roads; that he has examined all rules and regulations adopted by the Planning Board for the filing of Site Plans and will comply with same; that the plans submitted, as approved, will not be alter or changed in any manner without the approval of the Planning Board; and that the actual physical improvements will be installed in strict accordance with the plan as approved by the Planning Board. Budd's Pond Marina, Inc. Signed Owner William M. Witzke New York SMSA Limited Partnership d/b/a/Verizon Wireless, as Co-Applicant Signed (Partner or C rate Officer and Title) Sworn to me this day of 19,?&s?Gh J11, 614''__ �] otary Public INDIA DECARMINE NOTARY PUBLIC-STATE OF NEyy YORK No.02DE5060491 Qualified in Suffolk County 262 6 '41v Commission Expires 05-20 I Southold PlanningDepartment cG `/ Q Applicant AUG 0 9 2023 Transactional Disclosure Form :E 2023 Zoning Board of Appeals The Town of Southold's Code of Ethics prohibits conflicts of interest on the part of town officers and employees. The purpose of this form is to provide information which ran alert the town of Possible conflicts of interest and allow it to take whatever action is necessary to avoid same. Your Name: Robert: czarniawsk� on behalf of New York SMSA Limited Partnership d/b/a Last,First,middle initial Verizon Wireless, as Co-Applicant unless you are applying in the name of someone else or other entity, such as a company. If so. indicate the other person's or company's name. Nature of Application: (Check all that apply) Subdivision or Re-subdivision Site Plan X Other(Please name other activity) Secial exception Do you personally(or through your company,spouse,'sibling,parent or child)have a relationship with any officer or employee of the Town of Southold? "Relationship includes by blood,marriage or business interest. "Business interest"means a business, including a partnership,in which the town officer or employee has even a partial ownership of(or employment by)a corporation in which the town officer or employee owns more than 5%of the shares. Yes No X If you answered "Yes"complete the balance of this form and date and sign where indicated. Name of the person employed by the Town of Southold Title or position of that person Describe the relationship between yourself(the applicant)and the town officer or employee. Either check the appropriate line A through D and/or describe in the space provided. The town officer or employee or his or her spouse,sibling,parent or child is(check all that apply): A.the owner of greater than 5%of the shares of the corporate stock of the applicant(when the applicant is a corporation); B.the legal or beneficial owner of any interest in a noncorporate entity(when the applicant is not a corporation); C. an officer,director,partner or employee of the applicant;or D.the actual applicant Description of Relationship: Submitted this Z`I day of t&20 23 New York SMSA Limited Partnership d/b/a Verizon Signature Wireless Print Name—Robert czaruiawski Disclosure Form APPLICANT/OWNER TRANSACTIONAL DISCLOSURE FORM The Town of Southold's Code of Ethics prohibits conflicts of interest on the part of town officers and employees.The purpose form is to provide information which can alert the town of Possible conflicts of itake n hate�er action is necessary to avoid same to of this interest and allow it F�" CzQ�n1avJS� on behalf of New York SMSA Limited Partnership d/b/a YOUR NAME : Verizon Wireless, as Co-Applicant (Last name,first name,middle initial,unless you are applying in the name of someone else or other entity such as a company.If so,indicate the other person's or company's name.) TYPE OF APPLICATION: (Check all that apply) Tax grievance RECEIVED Building Permit X Variance Trustee Permit Change of Zone Coastal Erosion AUG 0 9 2023 Approval of Plat Mooring �(�3 L� Other(activity) � e an s permit Planning V r g :Zol1incg Hoard of Appeals Do you personally(or through your company,spouse,sibling,parent,or child)have a relationship with any officer or employee of the Town of Southold? "Relationship"includes by blood,marriage,or business interest."Business interest" means a business,including a partnership,in which the town officer or employee has even a partial ownership of(or employment by)a corporation in which the town officer or employee owns more than 5%of the shares. YES NO X If you answered"YES",complete the balance of this form and date and sign where indicated. Name of person employed by the Town of Southold Title or position of that person Describe the relationship between yourself(the applicant/agent/representative)and the town officer or employee.Either check the appropriate line A)through D)and/or describe in the space provided. The town officer or employee or his or her spouse,sibling,parent,or child is(check all that apply) A)the owner of greater that 5%of the shares of the corporate stock of the applicant(when the applicant is a corporation) B)the legal or beneficial owner of any interest in a non-corporate entity(when the applicant is not a corporation) C)an officer,director,partner,or employee of the applicant; or D)the actual applicant DESCRIPTION OF RELATIONSHIP Submitted this V day of � 920 Signature Print Name Robert iawski, Network Eng. - Real Estate RECEIVED APPLICANT/OWNER AUG 0 9 2023 u TRANSACTIONAL DISCLOSURE FORM " &31�) The Town of Southold's Code of Ethics prohibits conflicts of interest on the nart of town offiose cers and em to es.The ur Board of this Zoning Board of Appeals form is to provide information which can alert the town of Possible conflicts of interest and allon•it to take whatever action is necessary to avoid same on behalf of New York SMSA Limlted Partnership d/b/a YOUR NAME : Robert czarniawslci Verizon Wireless, as Co-Applicant (Last name,first name,middle initial,unless you are applying in the name of someone else or other entity,such as a company.If so,indicate the other person's or company's name.) TYPE OF APPLICATION: (Check all that apply) Tax grievance Building Permit X Variance Trustee Permit Change of Zone Coastal Erosion Approval of Plat Mooring Other(activity) e Tans s permit Planning Do you personally(or through your company,spouse,sibling,parent,or child)have a relationship with any officer or employee of the Town of Southold? GORelationship"includes.by blood,marriage,or business interest."Business interest" means a business,including a partnership,in which the town officer or employee has even a partialownership of(or employment by)a corporation in which the town officer or employee owns more than 5%of the shares. YES NO If you answered"YES",complete the balance of this form and date and sign where indicated. Name of person employed by the Town of Southold Title or position of that person Describe the relationship between yourself(the applicant/agent/representative)and the town officer or employee.Either check the appropriate line A)through D)and/or describe in the space provided. The town officer or employee or his or her spouse,sibling,parent,or child is(check all that apply) A)the owner of greater that 5%of the shares of the corporate stock of the applicant(when the applicant is a corporation) B)the legal or beneficial owner of any interest in a non-corporate entity(when the applicant is not a corporation) C)an officer,director,partner,or employee of the applicant; or D)the actual applicant DESCRIPTION OF RELATIONSHIP Submitted this day ,20 23 Signature Print Name Robe niawski, Network Eng. - Real Estate APPLICANT/OWNER TRANSACTIONAL DISCLOSURE FORM The Town of Southold's Code of Ethics prohibits conflicts of interest on the part of town officers and employees.The purpose of this form is to provide information which can alert the town of possible conflicts of interest and allow it to take whatever action is necessary to avoid same. YOUR NAME : Tanya Negron, , on behalf of Elite Towers, LP (Last name,first name,middle initial,unless you are applying in the name of someone else or other entity,such as a company.If so,indicate the other person's or company's name.) TYPE OF APPLICATION: (Check all that apply) Tax grievance Building Permit X RECEIVED Variance Trustee Permit Change of Zone Coastal Erosion Approval of Plat Mooring Other(activity) a an s permit Planning Lii als Do you personally(or through your company,spouse,sibling,parent,or child)have a relations employee of the Town of Southold? "Relationship"includes by blood,marriage,or business interest."Business interest" means a business,including a partnership,in which the town officer or employee has even a partial ownership of(or employment by) a corporation in which the town officer or employee owns more than 5%of the shares. YES NO If you answered"YES",complete the balance of this form and date and sign where indicated. Name of person employed by the Town of Southold Title or position of that person Describe the relationship between yourself(the applicant/agent/representative)and the town officer or employee.Either check the appropriate line A)through D)and/or describe in the space provided. The town officer or employee or his or her spouse,sibling,parent,or child is(check all that apply) A)the owner of greater that 5%of the shares of the corporate stock of the applicant(when the applicant is a corporation) B)the legal or beneficial owner of any interest in a non-corporate entity(when the applicant is not a corporation) C)an officer,director,partner,or employee of the applicant;or D)the actual applicant DESCRIPTION OF RELATIONSHIP Submitted this ,, 15 day of May ,2023 f Signature_,��1 t t-(•••,;� Print Name Tanya Negron, Managing Member RECEIVED APPLICANT/AGENT/REPRESENTATIVE AUG 0 9 2023 TRANSACTIONAL DISCLOSURE FORM Zoning oard I Appeals The Town of Southold's Cade of Ethics prohibit conflicts of interest on the part oftown officers and ntrn,rThe rc this form purime of is to provide information which can alert the town of possible conflicts of r3rterest and allow it to take whatever action is nccessarvto avoid same YOUR NAME: Robert Czarniawski on behalf of New York SMSA Limited Partnership d/b/a (Last name,fust name,jpiddle initial,unless you are applying in the name of Verizon Wireless someone else or other entity,such as a company.If so,indicate the other person's or company's name.) NAME OF APPLICATION: (Check all that apply.) Tax grievance Building Variance Trustee Change of Zone Coastal Erosion Approval of plat Mooring Exemption from plat or official map Planning Other Wetlands permit (If"Other",name the activity.) Do you perso4ally,(dr through your.company,spouse,sibling,parent;or child)have a relationship with any officer or emplo)Tc of the Town of'Southold? "Relationship"incliides;by blood,marriage,or business interest"Business interest"means a business, including ii partnershipjn which the:town officer or employee has even a partial ownership of(or employment by)a corporation in wh ich the town'officer or employee owns more than.5%of the shares. YES NO X If you answered"YES",complete the balance of this form and date and sign where indicated. Name of person employed by the Town of Southold Title or position of that person Describe the relationship between yourself(the applicant/agent/representative)and the town officer or employee.Either check the appropriate line A)through D)and/or describe in the space provided. The town officer or employee or his or her spouse,sibling,parent,or child is(check all that apply): A)the owner of greater than 5%0,of the shares of the corporate stock of the applicant (when the applicant is a corporation); B)the legal or beneficial owner of any interest in a non-corporate entity(when the applicant is not a corporation); C)an officer,director,partner,or employee of the applicant;or D)the actual applicant. DESCRIPTION OF RELATIONSHIP New York SMSA Limited Partnership d/b/a/Verizon Wireless Submitted this da of 20 2� Signature Print Name Robert C iawski Form TS 1 CO-APPLICANT'S AUTHORIZATIO RECEIVED AUG 0 9 2023 .7&39 Zoning Board of Appeals I� Robert CZarniawski , on behalf of New York SMSA Limited Partnership d/b/a/ Verizon Wireless, authorized co- applicant for a site plan and special exception application on the property identified as SCTM# 1000-56-3-15, in Southold, NY, hereby authorize Gregory R. Alvarez, Esq. to act as our agent and handle all necessary work involved with the site plan/special exception application process for this property with the Southold Planning Board. NY SMSA LIMITED PARTNERHSIP D/B/A/ VERIZON WIRELESS By: Sworn before me this 2-7 day of /'YJ�,��, , 20 23 INDIA DECARMINE NOTARY PUBLIC-STATE OF NEW YORK No.02DE5060491 Qualified in Suffolk County z,b My Commission Expires Or2Q 2 SOUTHOLD PLANNING BOARD SITE PLAN APPLICATION FORM RECEIVED Site Plan Name and Location AUG 0 9 2023 7B 59 Site Plan Name: Elite Towers at Budd's Pond Marina Zoning Board of ppeals Application Date: Suffolk County Tax Map #1000- 56 - 3 - 15 Other SCTM#s Street Address: 61405 Main Road Hamlet: Southold Distance to nearest intersection: +/- 600' west of Old Main Road Type of Site*Plan: New X Amended—Residential Zoning District Marine Il (M-II) Owners/Agent Contact Information Please list name, mailing address, and phone number for the people below: Property Owner Budd's Pond Marina, Inc. Street 61405 Main Road City Southold State NY Zip 11971 I Home Telephone (631) 765-3232 Other i A licanNew York SMSA Limited Partnership d/b/a/Verizon Wireless, as Co-Applicant pP Street c/o Amato Law Group, PLLC, 666 Old Country Road, Suite 901 City Garden City State NY Zip 11530 j Home Telephone (516) 227-6363 Other Applicant's Agent or Representative: Contact Person(s) Gregory R. Alvarez, Esq. Street Amato Law Group, PLLC, 666 Old Country Road, Suite 901 City Garden City State NY Zip 11530 t (516) 227-6363 i Office Telephone Other *Unless otherwise requested, correspondence will be sent only to the contact person noted here. Site Plan Applicotion Form 2.11812010 Site Data Proposed construction type: X New Modification of Existing Structure Agricultural Property total acreage or square footage: +/- 41,346 ac./sq. ft. Change of use Site Plan build-out acreage or square footage: +/- 2,450 ac./sq. ft. RFCED/E® Is there an existing or proposed Sale of Development Rights on the property? Yes N X AUG 0 9 2023 If yes, explain: Zoning Board of Appeals Does the parce](s) meet the Lot Recognition standard in Town Code §280-g Lot Recognition? Y X N If"yes", explain (and attach any necessary documentation—title report, subdivision approval, etc.) Building Department Notice of Disapproval Date: 1 / 18 / 23 i Is an application to the Southold Town Zoning Board of Appeals required? Yes X No I If yes, have you submitted an application to the ZBA? Yes X No I If yes, attach a copy of the application packet. i Show all uses proposed and existing. Indicate which building will have which use. If more then one use is proposed per building, indicate square footage of floor area per use. List all existing property uses: Boat storage and repair List all proposed property uses: Public utility wireless communications facility Other accessory uses: Existing lot coverage: 26.2 % Proposed lot coverage: 32 % Gross floor area of existing structure(s):+/- 10,800sq ft. Gross floor area of proposed structure(s): +/'2,450 s.f. Parking Space Data: # of existing spaces: N/A #of proposed spaces: N/A Loading Berth: Yes No X 7] Landscaping Details: Existing landscape coverage: 0 % Proposed landscape coverage: 4.43 Wetlands: Is this property within 500' of a wetland area? Yes X No Maybe 1, the undersigned, certify that all the above information is true. New York SMSA Limited Partnership d/b/a/Verizon Wireless Signature of Preparer: Date: 3-zlt-z By: Robert Zarn'awski 2 Site Plan Application Form 21118/2010 . f TOWN OF SOUTHOLD PROPERTY - OR® � OWNER :STREET -. i VILLAGE DIST.: SUB. LOT -C' � d `<R°".� f', r'�� PF-. �J`�� � 8f � d;`J.� ... �p,w.•-'' FORMER OWNER i N E ACR. S TYPE OF BUILDING - RES. f SEAS. ; VL. FARM COMM.- CB. MICS. Mkt. Value LAND i IMP. TOTAL [ DATE REMARKS i- ��'���;�y,wC ��,�"°�;,r�: :+: ���!�t�� ;��. ,z:y,>`• ,�,�`�Pt;.r,,•,ra r r_Tr�� �.,ii .';,,' �•;r,�.- Z,r`^ 3 - i t � O € O -- ---- 37 Won - C ® `g C � 7 Tillable FRONTAGE ON WATER iv Woodland FRONTAGE ON ROAD a Meadowl•and ; DEPTH House Plot BULKHEAD i 3 Tota I ` i COLOR TRIM i may.;,.»• ,,- .. ; _ F I I }' iIT f •x3`.' i � � I 1 I — i i i a� .. �.Y ..?r i l t % I; 1II 3jI!r —(-4.................._....................... MBldg. Extension Extension Extension Foundation Both k1I Ei! _ _ IDIi n ette Porch Basement Floors j, K. Interior Finish LR.Ext. 'Walls Porch :Fire."Place Heat DR Breezeway I� ' (N �c (J1 —�=C IType Roof IRooms Ist Floor BR. ; Room Rooms 2nd Floor FIN. B opatio DrivewayjDormerO g —__ oo� 'L— i' Total U, ( i RECEIVE® AUG 0 9 2023 ® 0 3� dw h Wir we TM RF Justification Report Site NYNYCO2239A _ RF Justification Report—Site NYNYCO2239A Contents 1 INTRODUCTION..............................................................................................................................3 2 WIRELESS TELECOMMUNICATIONS SYSTEMS........................................................................3 3 PERFORMANCE METRICS............................................................................................................3 Coverage........................................................................................................................ 4 4 PERFORMANCE SOLUTIONS.......................................................................................................4 5 JUSTIFICATION FOR DISH SITE NYNYCO2339A.........................................................................5 6 HEIGHT JUSTIFICATION FOR DISH SITE NYNYCO2339A..........................................................6 p�G 0 9 2023 of 70nin9�°aCd App 61405 Main Road, Route 25,Southold,NY 11971; Dish Proposed Antenna Height=130 feet 2 1 RF Justification Report—Site NY e R E F A- 1 Introduction AUG 0 9 2023 ��3 DISH is currently Building out Phase 1 of its 5G network. DISH had committed to the �i Rt�rltr6 Hl�peals 14, 2022, it will have deployed a core network and will offer 5G Broadband Servic the U.S.population and by June 14,2023,it will deploy a nationwide 5G network using DISH's spectrum with at least 70%of the U.S. population having access to download speeds equal to or greater than 35 Mbps. DISH submits this document in order to explain its standards and criteria for adequate signal strength, capacity,and reliability and how these standards and criteria are applicable to the Town of Southold. 2 Wireless Telecommunications unications Systems The FCC licenses a specific amount of RF spectrum to each wireless carrier and stipulates that each carrier efficiently use that spectrum to provide adequate wireless communication services to emergency services, businesses and individuals in the licensed areas. Wireless carriers achieve this mandate by continuously reusing the allocated radio frequencies throughout their licensed service area. This is accomplished by building small radio base stations, or cell sites, in a particular pattern (also known as a grid). The application of the grid concept affords a wireless carrier the ability to effectively and efficiently plan the reuse of radio frequencies. In order to provide effective coverage while maintaining an appropriate frequency reuse plan,the RF Design Engineer must perform a balancing test of all applicable technological variables. The primary variables that the engineer must balance/take into consideration are location, and the overall height of the cell sites. Too close and there is interference.Too far and calls are dropped. If a cell site is too high, it will have increased coverage but will cause interference throughout the rest of the wireless network, thereby significantly affecting network efficiency. If a cell site is too low, it will not provide effective coverage. Therefore, a properly designed wireless network design begins with strategically located cell sites. At each cell site there is a building, tower, water tank or other structure on which antennas are mounted. 3 Performance Metrics The critical issue for DISH is the provision of"adequate and substantial" Radio Frequency (RF)service to serve its wireless customers. The wireless industry is governed by the Rules of the FCC. The FCC mandates in CFR 47, Parts §22.940 and §24.16 that each carrier must provide "substantial service" in its licensed service area, or risk having their license revoked. The FCC defines "substantial service" as service which is sound,favorable, and substantially above a level of mediocre service. 61405 Main Road, Route 25,Southold,NY 11971; Dish Proposed Antenna Height=130 feet 3 0 RF Justification Report—Site NYNYCO2239A Coverage A metric called Reference Signal Received Power("RSRP") is used to specify the coverage capabilities of wireless networks. RSRP is the average received power measured across a 5G broadband channel. RSRP is measured in units of"decibels" referenced against 1 milliwatt,or dBm.The decibel is a logarithmic unit that allows ratios to be added or subtracted. The definition formula for decibels referenced against 1 milliwatt is dBm= 10 log (P/1mW) with P measured in milliwatts. So 10 mW would be 10dBm, 100 mW would be 20dBm, etc. The service boundary of a 5G site is defined using a RSRP equating to an acceptable receiver signal threshold. This value is derived from industry standards, 5G receive signal levels and quality and acceptable signal to noise ratios, along with statistically quantifiable variations in terrain. This threshold must also take into account additional losses associated with location of the mobile user. DISH must provide adequate service to all of its users. In order to account for users within buildings, additional margin must be added to RSRP so that adequate coverage exists inside. Industry and DISH engineering standards include an additional 10dB of margin to RSRP to be used for light suburban areas,with increasing values for higher density land usage.This additional margin is also required for in-vehicle service specifically to account for increased attenuation associated with the use of hands- free headsets,where the phone is typically placed on the seat or in the center console. An industry standard RF computer-aided engineering tool is used in the design of wireless networks. This tool is used to generate a plot of RSRP that shows underlying geographic data (highways, arterial roads, etc.). The propagation map is drawn showing the region where the RSRP equates to the minimally acceptable received signal level for adequate service, as measured at the device's receiver. The propagation map depicts the RSRP of the surrounding environment including the attenuation of in-building and in-vehicle use of service and visually demonstrates existing coverage patterns. Plots can also be generated to demonstrate proposed coverage patterns. With the preceding in mind, DISH' network standard for reliable 5G wireless service for highway and rural settings is -103.21 dBm RSRP. Network reliability and accessibility decreases dramatically for mobile devices operating in or traveling into RF environments outside (or weaker than) the -110.21 dBm RSRP coverage boundary for Low Frequency Band (600 MHz). Similarly, and as described above, signal level stronger than-98.21 dBm RSRP is used in areas where additional signal strength is needed to penetrate into buildings (e.g., city centers, dense residential, commercial and industrial type environs). RECEIVED 4Performance Solutions AUG 0 9 2023'--783q When the DISH Radio Frequency Engineer identifies coverage gaps in the system or I .Zoni.ng Board of Appealsave or will reach data capacity exhaustion, they issue a "Search Ring." A search area is a geographical area located within the inadequately serviced area, and it is designed such that if a wireless telecommunications facility is located within the search area,and at an appropriate height,it will likely provide the required coverage. For the most part, locations outside of the search area will fail to provide adequate service to the cell. Due to technological constraints, there is limited flexibility as to 61405 Main Road, Route 25,Southold, NY 11971; Dish Proposed Antenna Height=130 feet 4 ! 1 0 ' RF Justification Report—Site NYNYCO2239A where a new facility can be located, and still function properly.The goal of the search ring is to define the permissible location for placement of a cell site that will provide adequate service in the subject cell and work properly as part of the overall network. Justification for Dish Site NYNYCO2339A Dish is requesting to build a site based upon a concealed pole located at 61405 Main Road, Route 25, Southold, NY 11971,with a height of 130'AGL in order to provide new coverage in the residential and commercial areas and to offer contiguous coverage between neighboring sites. In addition, this site will provide significant offload of neighboring congested cell sites alleviating call performance issues while providing a buffer for the future traffic growth. Dish will offer good in-building coverage in areas between Middle Road & Boisseau Avenue towards West and Albertson Lane towards East.The outdoor coverage from site extends up to Horton's Lane towards West and Bayshore Road/Conking Point towards East. The accompanying coverage prediction plots exhibit the need for requested height and location. The dark green colored shade shows "excellent (deep) indoor" coverage. The light green colored shade shows "good indoor" & "excellent (in-vehicle) outdoor" coverage. The orange colored shade shows "good outdoor" coverage. If there is no colored area, it means there is no coverage or very limited coverage. 'tV NYNYCO2241A FAUG ECEIVED ' / f F •V� 0 9 2023 ,. 3 m^ Zoning Board of Appeals N�.YNY 0 279A •(i•.9� < Z. NYWCO2VOC" �! NYNYCO21008 '�„• '' ^ - Low Band Legend Color >=Value I <Value -110.21 j -103.21 103.21 -98,21 8.21 -20 61405 Main Road, Route 25,Southold, NY 11971; Dish Proposed Antenna Height=130 feet 5 0 RF Justification Report—Site NYNYCO2239A Height Justification for Dish Site NYNYCO2339A Based on RF simulation results, the height of 130 feet AGL provides acceptable RF and population coverage in the area. If we lower the antenna height, a major portion of coverage gap and population will be left uncovered. _.._------------------------.__ "RF Coverage(%)"-with'different Antenna Heights _................................................................................................................................-................:........................................................................... Objective 160 feet 130 feet ( 110 feet 90 feet ..............................................................__..........._.............................._......._.............._._..............._........__..............._....._.._......._..........._............................. .......i................... ......................................... . RF Coverage(%) a 85.67 78.52 67.78 52.6 Coverage Gap(%) 100 14.33 2 ..48 32.22 47.4 .._._......._._.._._.................... __.... .,. Gap,_(%),from 130 feeti 33 -50 -121 "Subscribers Covered(Count)"-with different Antenna Heights Objective ; 160 feet 130 feet 110 feet_ 90 feet --Subscribers(Count) — r 2814 — 2488 ; —1865 1258—� ......................................................................._...................................... ;....._._.......__........................................................._.... .....__._....__..__.........-- --- Subs Uncovered(Count) 3285 471 797 1 1420 2027 Gap m 130 feet 41 -78 -154 RECEIVED AUG 0 9 2023 7931 Zoning Board of Appeals 61405 Main Road, Route 25,Southold, NY 11971; Dish Proposed Antenna Height=130 feet 6 RF Report Proposed Southold 4 Communication Facility 61405 Main Road, Southold,NY v�,e,r, zo - n RECEIVED May 30, 2023 AUG 0 9 2023 7M Zoning Board of Appeals i C Squared Systems,LLC 65 Dartmouth Drive Systems Aub rn,NH 03032 03644-2800 E-mail:sul2l2ort@csquaredsystems.com ,s RECEIVED Table of Contents AUG 0 9 2023--T�Sl Zoning board of pppeais 1.0 Executive Summary.........................................................................................................................2 2.0 Mobile Communications System Design.........................................................................................2 2.1 System Considerations.......................................................................................................:.........2 2.2 System Evaluation........................................................................................................................2 3.0 Existing Network............................................................................................................................. 3 4.0 Site Need..........................................................................................................................................4 5.0 Resulting Solution............................................................................................................................ 5 6.0 Height Analysis................................................................................................................................ 6 List of Tables Table 1: Site Inventory Information........................................................................................................... 3 Table of Figures FigureA—Site Inventory ........................................................................................................................... 4 Figure B—Existing 700 MHz Coverage..................................................................................................... 5 FigureC—Proposed 700 MHz Coverage................................................................................................... 6 Figure D—Height Analysis Plot— 150 feet vs 130 feet and 110 feet........Error! Bookmark not defined. Figure E—Coverage Losses— 150 foot vs 130 foot concealment pole...................................................... 8 Figure F—Coverage Losses— 150 foot vs 130 foot concealment pole as a percentage............................. 8 Figure G—Coverage Losses— 150 foot vs 110 foot concealment pole ..................................................... 9 Figure H—Coverage Losses— 150 foot vs 110 foot concealment pole as a percentage............................ 9 C Squared Systems,LLC 1 May 30,2023 DECEIVED AUG 0 9 2023 1.0 Executive Summary �3 Zoning Board of Appeals New York SMSA Limited Partnership d/b/a Verizon Wireless ("Verizon Wireless") is a b ' of the State of New York and it holds licenses from the Federal Communications Commission("FCC")to serve the public within, among other areas, Southold,New York. Verizon Wireless' objective is to provide seamless,reliable wireless coverage to its users in accordance with the Wireless Communication and Public Safety Act of 1999.' Verizon Wireless, as a co-applicant with Elite Towers, LP("Elite")and the Southold Fire District, is providing the following information in support of their Special Exception Application to the Town of Southold in order to construct, operate and maintain the proposed wireless telecommunications facility in Southold,New York. This report addresses Verizon Wireless' need for the facility at the height proposed and confirms that there are no other feasible existing structures that meet Verizon Wireless' service objectives for this area. The proposed wireless telecommunications facility, to be located at 61405 Main Road, Southold, New York, is needed to provide coverage to address the existing coverage gap in the Southold area. Included in this report is a brief summary of the site objectives, a height analysis and radio frequency (RF) coverage plots showing the existing coverage gap and the predicted coverage that this site will provide to the Southold area. 2.0 Mobile Communications System Design 2.1 System Considerations Mobile telephony is a method of communication by radio consisting of mobile units,either mounted in vehicles or hand-held,that transmits to and receives signals from fixed base stations(cell sites). Base stations(cell sites)communicate with mobile wireless devices by sending and receiving signals within a small geographic area. The cell site in turn connects the mobile device to the landline telephone network. The cell sites are designed to cover a small geographic area because mobile telephony devices utilize low power. In addition,the frequencies licensed by the FCC are significantly weakened by obstructions, such as terrain, foliage and buildings which can make the coverage irregular and unreliable. Therefore, it is necessary to locate cell sites at suitable locations and heights in order to provide a seamless and reliable grade of service to the public. Seamless,reliable coverage provides users with the ability to successfully originate receive and maintain quality calls throughout a service area. Overlapping coverage is required for users to be able to move throughout the service area and reliably"hand-off' between cells to maintain uninterrupted calls. As a customer making a call in the vicinity of a cell site moves about and begins to move further away from the cell site,the coverage from that cell site becomes weaker. Unlike broadcast radio,as the customer travels,the call is transferred("handed-off')to an adjacent cell site,if and when that cell site's signal level becomes sufficiently strong. With sufficient overlapping coverage(i.e.,when reliable coverage areas are overlapping),this process is transparent to the user. To establish the necessary distribution of cell sites and help ensure that coverage is seamless and reliable, cell sites are strategically located throughout the licensed coverage area based upon,among other things,network efficiency,topography of the land,and the location of other cell sites. When a significant service deficiency exists, the ability for effective communication is diminished and service can seriously deteriorate in that region. In these conditions, customers experience the inability to make calls, lost calls,partial conversations, unreliable/slow data connections and/or inaudible conversation. 2.2 System Evaluation System design and evaluation is performed primarily through propagation analysis. Propagation models are widely recognized and accepted in the wireless telecommunications industry as accurate and are routinely utilized. Propagation models simulate how radio waves travel through the environment from one point to another. In order to accurately model the behavior of these radio waves, features in the environment such as elevation of the terrain (e.g. hilly or flat) and the presence of land use classifications must be taken into account. Land use classifications include such designations as buildings, water, trees, and others. Both elevation and land use data are required to accurately model the real-world behavior of a network because these factors significantly impact radio signal propagation. 'United States Code Title 47,Section 615,amended February 13,2003. C Squared Systems,LLC 2 May 30,2023 All propagation modeling performed for the proposed communications facility utilized high-resolution(30 meter)elevation and land use data. Since signal propagation characteristics differ through open, forested, residential or business areas, land use classifications are used to account for these differences. The model used in this evaluation employed a sophisticated diffraction based algorithm based on Fresnel-Kirchoff theory that takes into account the terrain and land use along the path from the transmitter to the receiver. A model was generated by collecting empirical data throughout the region and modifying user defined parameters utilized by the algorithm,such that a high degree of correlation between empirical and predicted results is achieved. When that is complete,the resulting propagation model software can predict coverage levels from a transmitter facility given the specific equipment configuration (antenna model, antenna height,power,etc.)of the site in question. 3.0 Existing Network Table 1 below includes Verizon Wireless' existing and approved sites that are located in the vicinity of the proposed site and details the network site-specific information used to perform the coverage analysis and generate the coverage analysis plots provided herein. Ground Distance to Antenna Elevation Southold 4 Site Name Street Address City Latitude Longitude Centerline(ft) (ft) (miles) Shelter Island 36 Menantic Rd Shelter Island 41.0664 -72.3508 160 28 3.0 Peconic Peconic Ave Peconic 41.0413 -72.4585 100.1 16 3.6 Greenport Relo Washington Ave Greenport 41.1093 -72.3677 180 7 3.0 Cutchogue 21855 Country Rd Cutchogue 41.0301 -72.4970 105.6 55.1 5.7 Cutchogue 2 31755 Main Road Cutchogue 41.0197 -72.4800 87 15.78 5.5 Shelter Island 2 61 Cobbetts Lane Shelter Island 41.0890 -72.3280 1176"/1121611 54 4.2 RECEIVE® Table 1: Site Inventory InformAUG 0 9 2023 Information AUG g 20 Zoning Board of Appeals Additionally, Figure A below shows a map of the existing and approved sites with respect to the location of the proposed communications facility. C Squared Systems,LLC 3 May 30,2023 Southold 4 61405 Main Road Figure A a 9 Southold,NY 11971 41°04'33.79"N 720 24'21.83"W GE:3'AMSL C ntedloe 146'1"&141'2"AGL 0 * subject Sire * Existing Site s �. Planned Site >=-80d8m `rGr" p -<-80&>=-85 d8m l ELTEh M V HO t SHEL a o, y. •. PE 1 k CHOOUE a . J Neighbor Shn ScuMold 4 Suw4o�NYoI�1 verizo Figure A—Site Inventory RECEIVED AUG 0 9 2023 7837 4.0 Site Need Zoning Board of Appeals The below propagation maps, included as Figures B and C, illustrate the existing coverage gap in the Southold area,and how the proposed communication facility at the subject site will remedy the coverage gap. There is a serious service deficiency in Verizon Wireless' wireless coverage in the Southold objective. A deficiency in coverage is evidenced by the inability to adequately and reliably transmit/receive and maintain quality calls,and establish and maintain data sessions. Due to the location and height of Verizon Wireless' existing facilities, along with the area topography,much of the areas surrounding the proposed site lack adequate reliable coverage. Figure B shows the level of existing coverage in the Southold area which is based on the minimum required signal strength for reliable in-building and in-vehicle service for 700 MHz frequencies, which are -80 dBm and -85 dBm, respectively. Verizon Wireless' knowledge,expertise and experience in designing and operating networks has led it to establish the appropriate coverage thresholds that are necessary and sufficient to provide satisfactory reliable wireless service in each of its service areas,including the Southold area. The white areas represent unreliable service areas. As depicted in this propagation map, there is currently a large portion of Southold,and the surrounding area where Verizon Wireless does not have reliable service.Figure B also depicts the site search ring area for the proposed communication facility. The proposed communication facility must be located within the search ring area in order to address the service deficiency in the Southold objective. C Squared Systems,LLC 4 May 30,2023 Southold a :e 61405 Main Road Figure B G sen ort West a Southold,NY 11971 � rVe 410 04'33.79"N n°24'21.83"W GE:3'AMSL Centerline 146'1"&14112"AGL Subjw Site �••� Existing Site Planned Site ->=-80 dBm -<-80&>=-85 dBm f + ipr SOUTHOLD •� 0 0.5 1 - miles t Existing and Proposed 61405 Main Road 1eeee1L norm g $OUtl101d 4 PREPARDATE:05/25/2023 D ON Coverage-700 MHz LTE Southold,NY 11971jr'Z�� •• Figure B-Existing 700 MHz Coverage 5.0 Resulting Solution In order to remedy the existing coverage gap,Verizon Wireless is proposing to install a wireless communications facility to be located at 61405 Main Road,Southold,New York,comprising the following: a. Six(6)panel antennas(the"Antennas")concealed within a proposed 150'-0"concealment pole(to be constructed by Elite),with Antenna centerline heights of+/- 146'-1"and 141'-2"AGL; b. An equipment platform upon which equipment cabinets and associated equipment,with canopy above,will be located, within the proposed compound(to be constructed by Elite); c. Four(4)GPS units mounted on the proposed equipment canopy;and d. All other appurtenances,devices,cables,conduits and wires related thereto,as more fully described on the site plans submitted with the application. The below propagation map included as Figure C illustrates how this proposed communications facility will remedy the coverage gap. RECEIVED AUG 0 9 208 -7$3eals Zoning Board of App C Squared Systems,LLC 5 May 30,2023 Southold 4 �� � 61405 Main Road Figure C i t Greeny rt West s Cre Southold,NY 11971 410 04'33.79"N e' 72°24'21.83"W GE:Y AMSL Centerline 146'1"&141'2"AGL & + SulOeetSite �_ • Existing Site , Planned Site 1 ' >=-80 dBtn i -<-80&>=-86 dD. R � L � t • ` i jr SOUTHOLD ! ti I t ; r T 0 0.5 1 i _ mile 83do ft and Proposed Stwfhold 4 61405 Main Road ✓ Coveeate-700 MHz LTE Southold,NY 11971 verizon DATE:06/tf1/102J Figure C-Proposed 700 MHz Coverage As can be seen in these plots,the proposed communications facility is ideally located to provide needed coverage to the Southold area. At 700 MHz frequencies, the proposed communications facility will provide in-vehicle coverage to 3.01 square miles of area, 1,087 people, 30 businesses and 19.5 miles of roads, including 5.1 miles of main roads. It will also provide in-building coverage to 1.93 square miles of area and 597 people and 16 businesses. RFCEIVED AUG ��023 6.0 Height Analysis Zoning Board of Appeals As indicated above, Verizon Wireless has a serious service deficiency in wireless coverage in the Southold area that the proposed communication facility, which includes a 150'-0" AGL concealment pole, has been designed to address. The proposed concealment pole is ideally located, and the 150'-0" AGL height of the same is the minimum height necessary to provide the needed coverage to the Southold area, address the existing topography, clear the surrounding tree canopy, and allow for additional collocators. C Squared Systems,LLC 6 May 30,2023 LZoniing EIVED 9 2023 rd of AppealsIf the 150'-0" AGL concealment pole is reduced by 20'-0", to 130'-0" AGL or further reduce ' " there would be substantial consequences to the proposed coverage that will be provided to the Southold area. . Specifically, with respect to Verizon Wireless,we have analyzed the amount of coverage losses that Verizon Wireless would suffer at the in-building(-80 dBm)and in-vehicle(-85dBm)signal strength levels for the 700 MHz frequencies. As discussed above, the currently proposed 150'-0" AGL concealment pole will provide, at 700 MHz frequencies: (a) in- vehicle coverage to 3.01 square miles of area, 1,087 people, 30 businesses and 19.5 miles of roads, including 5.1 miles of main roads;and(b) in-building coverage to 1.93 square miles of area, 16 businesses and 597 people. However,based upon our analysis, if the concealment pole was reduced to 130'-0" AGL, Verizon Wireless would provide the following, at 700 MHz frequencies: (a) in-vehicle coverage to 1.96 square miles of area, 687 people, 17 businesses and 12.6 miles of roads, including 3.2 miles of main roads;and(b)in-building coverage to 1.35 square miles of area,7 businesses and 365 people. If the concealment pole was further reduced to 110'-0"AGL Verizon Wireless' coverage losses would be even greater. At that height,Verizon Wireless would provide the following,at 700 MHz frequencies: (a)in-vehicle coverage to 1.36 square miles of area, 356 people, 5 businesses and 7.4 miles of roads, including 1.5 miles of main roads; and(b) in-building coverage to 1.01 square miles of area,3 businesses and 256 people. Figure D below depicts the loss of in-vehicle coverage area as the height of the proposed concealment pole is reduced from 150 feet to 130 feet and to 110 feet. Southold 4 T�� 61405 Main Road Figure D oven w t Southold,NY 11971 `� P 410 04'33.79"N < 72o 24'21.83"W GE:3'AMSL r06 r Centerline 146'1"&141'2"AGL k m• rook s { ' f i g SeRai old orth � f _ e SOUtTHOL a y � m e r ter �, hye � S o�,y .t• Nyo O 5K Hl0 0•`J Coverage Legend e mi (-85 dam coverage) _ le -4 ul ; ❑110 foot tower 130 foot tower ®150 foot tower 61405 Main Road t Height Analysis Southold 4 Southold,NY 11971 verizort✓ DATE:OSfSlR02.7 Figure D-Height Analysis Plot-150 feet vs 130 feet and 110 feet Based upon the above data, Figure E below reflects the calculation of the coverage losses from a height reduction from 150 feet to 130 feet to the Southold area in terms of square miles,population,businesses and miles of roadway. C Squared Systems,LLC 7 May 30,2023 -80 dBm -85 dBm Loss of Coverage Area -0.58 -1.05 square miles Loss of Population Coverage -232 -400 pops Loss of Business Coverage -9 -13 businesses Loss of Road Coverage Total -6.92 miles Main -1.87 miles Secondary -5.01 miles Figure E—Coverage Losses—150 foot vs 130 foot concej- eut-pele—'t5i Figure F below,reflects the calculation of these losses in terms of percentages. eals -80 dBm -85 dBm Loss of Coverage Area -30% -35% square miles Loss of Population Coverage -39% -37% 1 pops Loss of Business Coverage -56% -43% businesses Loss of Road Coverage Total -36% miles Main -37% miles Secondary -35% miles Figure F—Coverage Losses—150 foot vs 130 foot concealment pole as a percentage In summary, based upon the foregoing data and analysis, Verizon Wireless would lose up to approximately 35% of square miles of coverage and 39%of the population to be covered,as well as 36%of roadway coverage if the proposed concealment pole were reduced to 130'-0"AGL C Squared Systems,LLC 8 May 30,2023 Also based upon the above data,Figure G below reflects the calculation of the coverage losses from a height reduction from 150 feet to 110 feet to the Southold area in terms of square miles,population,businesses and miles of roadway. -80 dBm -85 dBm Loss of Coverage Area -0.91 -1.65 square miles Loss of Population Coverage -341 -731 POPS Loss of Business Coverage -13 -25 businesses Loss of Road Coverage Total -12.1 miles Main -3.5 miles Secondary -8.6 miles Figure G-Coverage Losses-150 foot vs 110 foot concealment pole Figure H below,reflects the calculation of these losses in terms of percentages. AUG ® 9 2023 7 / Zoning Board of Appeals -80 dBm -85 dBm Loss of Coverage Area -47% -55% square miles Loss of Population Coverage -57% -67% pops Loss of Business Coverage -81% -83% businesses Loss of Road Coverage Total -62% miles Main -70% miles Secondary -59% miles Figure H-Coverage Losses-150 foot vs 110 foot concealment pole as a percentage In summary, based upon the foregoing data and analysis, Verizon Wireless would lose up to approximately 55% of square miles of coverage and 67%of the population to be covered,as well as 62%of roadway coverage if the proposed concealment pole were reduced to 110'-0"AGL. Pursuant to the foregoing analysis, Verizon Wireless would experience significant coverage losses from a reduction of the concealment pole to 130'-0"AGL,which losses would be even more severe if the concealment pole were reduced to 110'-0 AGL, As such, the proposed communication facility with the 150'-0" ALG concealment pole, is the minimum height required in order to remedy Verizon Wireless' existing coverage gap and provide needed coverage to the Southold area. C Squared Systems,LLC 9 May 30,2023 7.0 Summary There are no other existing feasible structures upon which the proposed communications facility can be sited to provide the coverage requirements needed for the Southold area. The location and the proposed minimum height of the concealment pole were chosen to achieve an optimal balance between meeting coverage objectives, clearing the local obstructions, and minimizing the aesthetic impact to the community. As depicted in the enclosed plots,the proposed Verizon Wireless communications facility, with Antenna centerline heights of +/- 146'-1" and 141'-2", is ideally located to provide the much needed coverage for the Southold area, along with effective connectivity to the rest of Verizon Wireless' existing network. Our analysis confirms that the proposed communications facility will provide reliable wireless coverage and remedy the existing coverage gap in the Southold area. As shown in the Height Analysis, reducing the height of the concealment pole to 110 feet AGL or even to 130 feet AGL would result in significant coverage losses compared to the proposed height of 150 feet AGL. Constructing the tower as a concealment pole instead of a standard monopole to reduce visual impact of the communications facility already significantly reduces the flexibility of wireless operators by restricting the size of antennas that can be deployed and the azimuths at which they can be oriented. Any reduction in the height would further compound the impact of this limitation. Without this proposed communications facility, at the height proposed, significant gaps in coverage will exist (and remain) within this area of Southold. Therefore, based upon the foregoing, the proposed communications facility should be favorably considered by the Town and the application should be granted in all respects. 8.0 Qualifications, Statement of Certification and Resume I am a Radio Frequency Engineer for C Squared Systems, LLC, which has been retained by Verizon Wireless. I have extensive experience in the design and testing of Verizon Wireless' communication facilities as part of its federally licensed network in New York. For example, I have participated in the design and performance of the Verizon Wireless network in New York,participated in engineering efforts to provide a quality system build-out,evaluated zoning provisions applicable to wireless communication facilities in various communities, testified before local zoning boards in zoning hearings, prepared search areas for new installations, participated in drive tests and reviewed drive test results, participated in site visits, prepared RF designs for proposed installations, reviewed plans and prepared RF packages for zoning hearings, tested and evaluated new sites,and located and corrected system performance problem areas. I have been involved in Verizon Wireless' design of the proposed wireless communication facility at the above proposed communications facility. I have personally visited the area,reviewed coverage data for the proposed installation,and reviewed RF coverage information for Verizon Wireless' existing sites. I certify to the best of my knowledge that the statements in this report are true and accurate. May 30,2023 Date Martin J.Lavin C Squared Systems,LLC RECEIVED AUG 0 9 2023 �83� Zoning Board of Appeals C Squared Systems,LLC 10 May 30,2023 Systems martin.lavin cs uareds stems.com @ q Y SUMMARY: Over thirty-five years of experience in the RF and wireless communications industry. EXPERIENCE: C Squared Systems,LLC 2008-Present Senior RF Engineer • Zoning Hearing Expert Testimony • Advanced Wireless Services RF System Design • Wireless Broadband Access Systems Engineering • Drive Test Services • Intermodulation Studies • RF Exposure Studies U.S. Cellular,Bedford,NH 2002-2008 Senior RF Engineer • West Virginia/Maryland/Pennsylvania CDMA System Design and Optimization • CDMA Capacity Planning and New Site Builds • Subject Matter Expert for E-911,Public Safety Interference Issues, Collocation,and Technology Transitions Independent Wireless One(Sprint Network Affiliate),Londonderry,NH 2000-2002 Senior RF Engineer • CDMA System Buildout in New Hampshire and Vermont • Organized Field Office • RF System Design and Site Selection Point of Contact with Site Acquisition and Construction • Capacity Planning • System Performance C Squared Systems,LLC 11 May 30,2023 Nextel,Reston,VA 1999-2000 Senior Manager—Technology Development • New Feature Development for the Motorola MEN system • Corporate RF Engineering Standards • Evaluation of international and domestic spectrum acquisition opportunities USI,Chantilly,VA 1999 Program Manager • Software development projects in Europe and U.S., including budget and schedule responsibility. • Direct client contact for requirements gathering and proposal writing. LCC International,McLean,VA 1991-1998 Manager of Engineering • Domestic and International Cellular&PCS System Design and Buildout • Nationwide GSM Network Buildouts of Australia and New Zealand • FCC PCS Pioneer's Preference • Strategic Planning for LCC Initial Public Offering • Responsible for RF Design and Site Selection for Los Angeles MTA • Wrote network equipment RFP for two PCS MTAs • Software Product Manager for CellCAD,ANET, and MetroNET • Managed Drive Test Services, including all Timesheet and Expense Approval Carl T.Jones Corporation/SAIC,Springfield,VA 1987-1991 EMC/EMI Engineer • Test and Measurement consulting for FCC compliance • Broadcast(AM-FM-TV)consulting EDUCATION: University of New Hampshire—Whittemore School of Business and Economics Master of Business Administration Rensselaer Polytechnic Institute Bachelor of Science,Electrical Engineering RECEIVED AUG 0 9 2023 Zoning Board of Appeals C Squared Systems,LLC 12 May 30,2023 Ambassador Abstract, LLC 160 E. Main Street Huntington,NY 11743 Tel (631) 923-2410 Fax (631) 923-2409 RECEIVED A May 16, 2017 UG 0 9 2023'� 8 36] Zoning Board of Appeals John J. Coughlin,Esq. Re,Nielsen,Huber&Coughlin,LLP 36 North New York Avenue Huntington,NY 11743 Re: Title Number CRA-7814-17S Premises 61405 Main Road, Southold,NY District 1000 Section 056.00 Block 04.00 Lot 013.002 District 1000 Section 056.00 Block 06.00 Lot 002.002 District 1000 Section 056.00 Block 03.00 Lot 015.000 County Suffolk Dear Mr. Coughlin: In reference to your request for an Attorney Search on the above property our company has performed said search in Suffolk County effective as of 04/01/2017 and has found the following: TITLE FOUND IN: As to District 1000 Section 056.00 Block 06.00 Lot 002.002 and District 1.000 Section 056.00 Block 03.00 Lot 015.000 Record Owner: Budd's Pond Marina, Inc. By deed made by Southold Marine Center Land Holding Corp.,to Budd's Pond Marina, Inc. dated 12/15/1981 recorded 12/23/1981 at Liber 9120 page 75—See Attached As to District 1000 Section 056.00 Block 04.00 Lot 013.002 Record Owner: Budd's Pond Realty, Inc., By deed made by Vincent P. Geraghty to Budd's Pond Realty, Inc. dated 07/14/1982 recorded 005/1982 at Liber 9222 page 238—See Attached MORTGAGES/LIENS 1. Mortgage from Budd's Pond Marina, Inc. to Southold Marine Center Land Holding Corp., for$101,000.00 dated 12/15/1981 recorded 12/23/1981 at Liber 9169 page 418 COVENANTS AND RESTRICTIONS,ETC. Declaration of Covenants and Restrictions as set forth at Liber 12012 page 759—See Attached Notice of Appropriation as set forth in Liber 12390 page 610—See Attached RECEIVED Notice of Appropriation as set forth in Liber 12403 page 876—See Attached Reservation and Easement as set forth in Liber 9120 page 75- See Attached AUG 0 9 2023 JUDGMENTS/OTHER LIENS 713 I RETURNS -NONE Zoning Board of Appeals The above information is being reported from an Attorney Search. Such a search can be converted into a title commitment if need be with only additional searches run against proposed insureds. Until such time as a title commitment is ordered and a policy issued, this company's sole liability is limited to cost of this search, if title Insurance is required please contact this company so that additional searches can be run. As you are aware, Ambassador Abstract, LLC is a full service title company committed to providing you and your clients with the highest level of professionalism and title services available. Since we have already begun the title work on this property,we would be able to provide you with a full title report in a very short period of time. We would be more than happy to work with you to provide an accurate and clear title report in an expeditious manner with a significant cost savings to the purchasers. Very truly yours, Am6assadorA6stract, LLC Enclosures I • RECORDED Ntunhcrurpaµe.������� rtntul N` 00 JAN I I PM 12112 tiartsta EDWARD i s ROMAINE Cenllkatvu GURK OF •-- SIIFFO}.K MINTY INTY lkcd r AhutyaCc InaturNKt Ik•N J hkutgaxe 1'u�tilnnlp I[nitrdiul;l I'iliny Stmnpt t'rye►I'Rmr 1 ee ,.. Ahmltnne Ana DECEIVED Nulaltun Sub Total AUG 0 9 2023 FA-522 17(t'twnt)) _ _..... tiuh'Ldul Stec4Vwt 3 (A•t:r7(Slalet sl. in�Id _ Z Hing Board of Appeals' Inl MIU.IAX t'mun.ori•d t Uti 6� 1.. �� Ilual laWu____l+untt'uuutr�,.• Heid I..t Appolltnnntrnt 'crtittcd Cupy , ���G�J1rt+1 s;i�'S`�y ARutuuu lu. .. _^W ttC t he(N.�ctly come-I 6y th{i iii.nlKnl!r t�or Kcy.Copy _ ..ilt be tutprtirc.l by a tint.0 e tit tlautily duellittytmlr IiKANI)IMAI, •�_,_ ll N0,49C aplu.galalr In%t-tause uo Imite u W llni In.lfuntcnl t Iteral l'tup:rtl'fattienicrAueutyVvritkntiwt a l'nnuuunit }'resrrViltitin 1'1113d 1h�L tiruruo lthR! Lut t'un�fticrttlian 11tn�tutu S 0 1000 056.00 04.tl0 011.000 t'I'I 'l'ue 1h1e i-.0 - 100tl 056.110 04.00 019.002 hnptn.cd X bu ' VncunlIand L rUtrcIn+tgc�ltrleu.cw l.i+l t'rulurty t hutrt,Mail mit Addie 1 I) - IIBt'ol(l)&tiffullm io: --•- .— Fudolpa It. Uruar, Esq. ll) 35000 Main [toad 1I) P.O. lax 1466 ••--•- Southold, Nov York 11971 K TIM.('omplitly Inl'llrnuitiliu ;its; _•_......._. St1i �uk C �u1t Zc ,oidln & Endorsement Pa4 lltiy�tty0 li+ttttt glut til'tlk ulllkltal _ Jww COVtlltant ..• .. . utndc ly: tti}'i:t7f5' 11'I'I:uI•IN�IttttolliNt'i ,— 8udd'1. Pond 1tealty,ine:��- —'witl67H.'i;wliainind -- 'llu}vrndxrclu'niut.sittadalnt I u to 1110•t'ut�arllir"I•„soi�t,ha)d,�_`•��„�_. or I 1ANII.E.Ttil Southold Ilt��I S S 111111)N Nit 1st.Ill: t 19'1:1)Olt PRINl1:U IN III At.•K 1NK t XNL)I't'IUta}t 11)ttI:Ct Utl)1Kt i 1 Ilt l tl.lhti. tOVBR► RECEIVED AUG-0 9 2023 !) XTARATION Ol;C'OVENAN'TS ANO 111"N"JAWTIONS / (23cl Zoning Board of '1'f IIS 1M.CLARATION madc by DillAVS POND RUAL TY. INC'.,it domestic Appeals eoruiration huving its principtll plate oThultitiass tit(Notll Main Road.Andiamonmtiuc, Tow)ol'Sou11,01d.County ol'Surlblk and Stutc orNcw York 11971, WILLIAM 11- l.tf:lll.l:lh',residing ill d ivy I1111ce,Slicitcr Island, Now York 11964 and KAF LIHILFIIN',resitting til nal C'cntrul Avenue.Grcanport, Now fork 11944,hcrcinuller rellmed to its lite I)I:CLARAN'1:S,im tine owners ol'premini;described ill Sehctitile"A" unmxcil hereto(l►ercinuRcr rolerrod to its the PREMISES)der-ire to restdci t}tc tirc anti clljuynicnt orsaid PRliivllSUS utnd have ror such 1111"508 determined to impose on said PRHMIS1:S covi;m ils and resirictiolis told tlu licreby duelurc that mitt 1'1tf:MltitiS sllall be I cltl n11d sllull Ila elltivcycd Kallicct to lite rullowiltg covenants told restrietions; I. OECLARAN°1'S lave mudc application to lite N"ty York State Department of*hivironmcalal Cunsen'ulion(Itcrcinnilcr rclarred to us to the WaiAWMIE:NT1 lar 1110 comitnictiuil uric builtlilig tell pretillscs tlescrihcti Ill ScIletitllu"A". 2. Asa coildition for tliv upproval IMPAR T�IMUNT Iles ugrccti to the eontitnictioii ol'tlie building upptied for upon I)IiCLARANT'S imposing the rulluwing 0utit'muri alai Tesirictintl and M:CLAHAN'I:S hereby impose till slut!1,I(I MISI:S the rollowing covanaat and restriction: "Rcguhoed 1reshwaler wedurids ursochited with NYSIXV Wctland SO.22 the located on or ncur(tic properties ut'Build's 11oud Rutty,Int:.,Willitml I L Lichlcin,Kne Lichlcin and their heirs,assigns or successors. 'Phis property is suhjc�ci to lilt provisions orEnvimiinncntul C'onscrvulion Low(EC'L?Article:a,unl the conduct orreguiattrd nctivillc's nuty occur only purmam to 110. Arlivic 24 if prior upprovul k given by rile New York State Department of linvironnlclttul Conservation MYS1) -0 or its uueccssorm. Regulated activities iauilide,hilt lac not linuted to clearing ol'vcgetntioll; uppllcaliotl ol'chcnliculs;escuvltttun;grading itnd 1111ing;told erection oruny smteture(s)." 'Phis C oviniult and Restriction is In take r.tl'cct only and lit suelt little as and witch Ole above permil. 0111 nvise;it is to have no ibrec laid cn'cct. 1101 t1'ti I )Nl>!tt iAt' , tic'.,E10 William Il. 1-101110111,hnXlden` Ydilunl Il.I.tr dam Kae Wuhluin RECEIVED SCHEDULH „A,. AUG 0 9 2023 7� 3 �DESCRIPTION UI:PROPERTY Zoning Board of A peals DEs't,'I.ARANTS Ilu dd's iron l Realm Ing- Willi f►p l if, i ghlg n,E;rd Kuc Lichiisn ALi.that certain plot.pica or parcel of land,situate,lying and being in thc'rown orSoutitold,County of Sitlrotk And Stnme.of New York,being bsutndcd And described no Follows: BEGINNING tit tl paint on Ilia northerly aide of Maiir(State)Road where tits southwesterly corner or Innd hercinAllcr described and the southcustcrly comer ol'land now or romerly of Port crE:gypl Enterpritea. Inc..intersects same; RUNNINGTHENCE North 20 dogrccs SS minutes 40 sccondx Wcat,along land now or formerly of Port of Egypt ITtiterpriscs, Inc., 1(1c)At)teal to hind now or fanttcrly or the Long island RAilroud(Io.-, RUNNING THENCH North 61)degrees 04 minutes 20 secanda E;nit,Along land now or forntuly of the Long 181and Railroad Co., 100.00 Net to Bind now or formerly of Build's fond Realty; RUNNING I'll FNCC.South 20 dcgrcca SS minutcK 40 seconds Bast,along land now or formerly of Budd's Pond Ronhy, 100.00 feet to clic northerly aide or Main(State) Road; RUNNING TH[:NCI:South Gs)dcgrm 04 minutce 20 kee'ouds West,ulong'the narthcrly side of Main(State)Road, 1tN),Ixt rest to the point or place arl DOWNING. PARCm. 11 ALL that conin plot,pleat:or parcel or iund,situate,lying and being in tite Town "I'Soutiwld.County ot'Surrolk and State or New York.being hounded and descrihed AV follows: Bi-GINNiNG tit a point on tic northerly attic car Main(Stoic)Road where the southwesterly corner of tand hercinnticr dcacribed And the southanaterly corner of land naw or fantrcrly of Willium I.icblcin intersects fume; RUNNING THE++NCE?North 20 degrees SS minutca 40 sccunds Haat,along land now or forincrly or William l.iehlcitt. 100Jl0 reel to the soullierly side of the Long Island Railroad Co.; RUNNING'1 THENCE North 6+r degrees 04 minutc6 20 seconds liusl,ulong Intl mentioned Innd.250.0(1 feet to land Clow or romicrly arCcacghty; RUNNING THENCH,South ell degreem SS minulaK 40 sccoudK bast,along land now or romcrly orGcicghty, i001H)feel to lite northerly side or Maitt tilalcl Road; RUNNING THENCP.South t►s)ticilrecs 04 minutes 20 Kcconda Wert,along the northerly We of Main(State)Road.250.00 reel to the paint or ala«or BEGINNING. 12OUPC 759 - P,i-�'=.T\/ED s t'A'Plti l)) Nt:w ti'n1tK) AUG 0 9 2023 �) �Ba9 E•(IUN•I't'triF SUI.I�E)I.K) .4% 1 Zoning Board of Appeals On the il ilay 00411unry, in tllu year 2000,bclbre fnc,the undcrxlgn� , perxonnlly uppcarcd William Liehteiti,perxosiully known to Iitc or proved to tilt all the hasis of satisfactory eviticllcc to bu Ilsc ittdividllul(s)Whose illtntc(K)is(are)subscrihcd to the within instnimmm stltcl ucknowictigcd 10 nic that he/shelthey emccutcd flit,,lime in hts/hcr/tWir cllpacity(irs),lull shut by Ids/lierhheir llignatufv(s)oil file instrument,fhc ind'+vidunl(>s),or the porson upon beitulrofwhich thu Individual(s)ilc eti,exccu(c tllc invinlnlcnt. MQNIOUR M.MA'CUNANA Nobly Public,f3u►le of Nws tit No.0WAed03e07 /'y (} DonKt*+tQ`utoelti ttxSuffolk tic �0� 7. .�Q . K L! !,1 U'!'A Zl'III Ill.it' 8TjVI'1?01 NEW YORK) ms: (100h'i'Y OF SUFFOLK) On the .)'tday of lunmory,in the your 200.before mc,the undemigilcd, perlonully appeared Kut Licblem,personally known to nic or proved to me on flit basis ofsulisrae(ory cyidence to be Nie individual(s)whose 11111ligg)hl(arc)subscribed W fila within instmmient and ucknowlcdged to ilia 111111 ltc/shelfltcy executed the same in his/her/their capucity(ics),unci that by his-flierlgicir aignatwc(s)on file instrument,file indivldual(Y),or file permon upon bcilall'orwhich IN indlvidtiul(s)acted,execute tilt itl!lttUtnCllt, NOTA Y Irl HER, • ��' ----•�. .:...�:�.�.,. ..�..._...._....�i'�.._-..-ti'S/.?s?�' ,.:' .t,.; ill�° a..rr f1.1 t C./w.s..a.o,r -�..W+.��.,�ri+wa err.►L.a�n..._ ....yw w t:,,,.wr�t ry • �*YMahhArvett st�tlsMarDlyd*fl> .?11ts UrlfailfhsflsEfOdlilt YsftihEl!fJtMhtsssfillLlf :(; 'O ' •n� '0�•J MWR(D& ,traded,c 6ftth day*( July ,nizet"chundrWand 'eighty-tt > 1 �tISC8N1' P. GEIi]1G1'; Qom Lane, Shelter Wand, H.Y. 1000`. oithe firR .•�. fiTrOC✓; ! am= PONd RS IXOt'WC. --;-, Main Road, 04.00 S(Mthold, H.T. W7 AUG 0 9 2023 013.0/02 1 ► of aK 0=4 c..t. :: gal of mer,�ePa� s,.e��aeem;onac, saa «heeeea honing Board of ApP Arid by dee pony of the etead pct,dart hetebt,graat and reksse udo the party of the accoad Part,the heirs a snaessors sod a 4s n of the ferny sf the f%i Q)an faaerer. ASL thatMasa p1a.piece or lw-d of b.md.with the Fundings and hr-Ptovrammta tbettoa erWtd,t:itoace, f;gxMd=!M2 at Ushtua=que, in the ern of Southold, County of Suffolk and'State of New Yorke kr,nwn and designated as the northerly %i Permian of Iota 21 to and Including lot 25 on a certain map entitled,_, 'Map of C. L. Sanford Brick Co., lnc.•, filed in the Suffolk Couatyi Clerks Office on Septetaaer 2, 1931 as Map No. 539. SUNG the rine ltrmitsas ,conveyed to the grantor herein by deed hated June 15, 1978 recorded im the office of the Clerk of Suffolk County on :July 14, 1970 in Liber 8461 cp. 352. J 2U panty of etre second part has simultaneously heretith exeeutfxi cad delivered a pmcchatte mossy mortgage in the stmt of $90,000.00 intended to be reworded sinultanemaly herewith.: i�EAL E5T1t1E S „ [A% couffly ,:. TMATHER woh A r*ta.tide rmd hftt 6-if any,of the party of the�fir�e__ part n and to any sums and tv,ds a4mntts tier ataose detc*sbed prerina to the cent-r lines thtmf:TOGETHER with ehe•fpporta,s:taa cad ail d..saute and tion of the p,ny of the first part in a. 'to said premises-TO HAVE RM-0 the Pr rains srrem seaeeed vrdo et:e patty of the mvaC Ort,the!.fn or soce-ssom and>nkft-of the party of the ftcasd put foterer S AND for pan) of the fast PM eor,eaatsts that 1-v party of the first pan ha.nut Jane or snRetrJ aa;t6ie<< rt,enfn the_4p.rtmses f+a►e bees exumDeitd is any ray r-hstcvee.except as aforesaid. AND the perry of de Ani pat is tomp* nit}:ccvct;on 13 of the Lica faw,crneannt►that the party of sk firg Pact v -`M,i—dw mdrratWo i., .;p conaeyan0e and wW hold the right in rective such omsid- ' ertriaa as a tet food m he spend fall to:,1-,parPoat of psv;as r1K cwt of the h n,raveMeAtandwMapQ1y -A t3,r sa►sr Orr,t 41Jre Miaea o�dee cgst of 6ttt imp onwcrit before ming any part•.�the foul of the state for 71acme pay- 71M--d coamwd as if it mad parties-whenc-.W the scaxof this indcntpre fo tcquires. WiiR>ZSi .fir pasty of first part las daly e:tcute3 tltia decvf the ti:y andyrar fust shore r i 1r ftrsfa=or- it �qrla e. cff�r ;t ` :i ; .;,. entry dw m Si1Nt7.Cewm elf y0♦S,w sk MM e p Ow TM O 11 OF On the li der July 1982 .beffte me Oa the Oar of 14 ,waft tae" penooati+•erne pataoa0y cum vxmcs Q P. GEPAGun to cm&-"to 6r the 6&rirhid dtanited;a aat wm to we 8twwo to b► the iaQirimeoed is ud tvm e�4 fwtg ibtecseea*.=I adrrawlc�l tbtt ea•.a�d MA0 {esltumeat.=4 at=.Ac*w dot r i� f oq tal► aewey oR es, StAls w wo Von.town w RECEIVED fia the 4a,►of 19 .bvfo:-e MA Oa t5e _ day of 19 .befan Y eai+e �e dw vA0� P-0-4 tee°at xa °�t'`w°'�.dd tam ,� the fo tt et;}, r • AUG 0 2023 PRS r— .�be;arr 6r.e "• ���. dt�at br is else twaar.did depute tt+d ur tx�t be tttidet et Na the eetpa m;aa tle.,2*d .ing Board f Ap M iOd r'hidS eaxt+t d tAe.otftmqim hwitimm t dm be to be the b"" d* LW al MW C11I '-i=, 73ttt the eel SM3Md dtatebed is aed teb0 eXkCU d ft fatYagin fittt4aRltf to"w a m. is"Ich aotpenoe cud;trot it was an tfat be. aid wbwrun witom gra pane ved few• mrd by etdn of the board at 6nmft of aidcapett+- n the frac i tad" be,tai!'11IWI , M& •;Y�y and be KWA h MUM tfasto by lia tied.. a the am time tabatsaod h arae u rdane • ' {L r 18W*Dreb DIST.!t• 1000 WON CVVP-A rr t"mv Casxtaa's:1cnt st,C(tax 058.00 7tit:! R9d79695 Mom 09.00 f tic 013.002 . To oaumw oft xoaex Southold BUDGE POS aft"d 7Y4 CHWAGC Tstaz M07W.tRM Maur i' tturw E:;m %"-a"tetAMSCHWABYZ ti MR, Saye.E 150 Broads+ay Su1te, 2001rw New York, NY >' a►w•10038 i1 r: t• ras••.x � >Irrld[i.taitl.MrialV.fJhJW-iwi�/Li.Orl,diGr.+r.yi..Gtarrh 4m-i.CW ;�} L• I• �j f-1) (_tNaMN!p0ta3■tsm s`Y t�rta�ilik OCT.'''PLeWMMMMrgTMgrip1 75 .� 3.51x'0 7H� MtUMW,made tbo 15th 4-) of Damv,:Ar .am.huadrod and eighty ane WLTWIX f SOMOLD MARINE CKHM IMM H=IMG CMF.. a domtrtic corporation hiving its principal office and plaeo of busi- ne" at (too !) Main Road, Southold, Now York, 119710, r row 1 party of dafmapsr;=d BODDIS POW pfABl &s Im. a dowstic corporation btvilog its principal Office and place of bvainass at (no #) lain :. ass-*40Read, SoutbOld, MM York, 11971, IL RECEIVE® �A Wq Cif ftSMWput, AUG 0 9 2023 Ot0Z.000 tit the part,of die sru _ - - - / -� _ parr,is e-e of ^ + ' - - - - - - r.a and no/100 ($10.00) - act ung Board of Appeals awaer of:be Udted Stoeex and other valus`.+te Canaiduratioa - - - - pdd al the p'as7 of the wowed part,does bUdY grsas cad Ft C aft the party of the secondimn,iUe ben-cc , ase�aart .d at the FM7 of the—Ad part fm—. Pati`cel CM t AU.Jut renaia pSal,piece or rayed of fsad,%ith the bwIgnrs and improvements a erooa erceted,situate, btia[ke tW •1'ovn Of 809thOld, Count:? of Suffolk and Stato of Efet► Yorks being more particularly bOtu-ded and described an follows: 6MZMN;NG Mt,d point an the SOuthstr1yy side of gain State Road at thlr northeast coaster of the herein doscribed prcuiees where the Daae is intorseCtod br the Westerly aide of iandnow or foscrly of Morris] r=ing thaocet fres said point or-place of begittaittg along land nwr or forslIIly of Morris, the follovittg 3 eourmm and distances 1) South 27o 61. 2L Fact 196.25 feet; 2) South 71a 35- 00" East 11x.0 fest, 3) South 230 30. 00- great 72.95•teat tO the wean high Water auk of Budd's fk gdl thence A&M 5oa �E4 a tie std' S0" Wei 269.31 mark to lauM nd tial► otpo lformerly of Booths that►oe alar y said last aan>,tinned laod North 190 41. 00■ West 250.00 fslar« to thR southerly tide of main state Road{ and tbence al-9 the sauthfrtix aides Of Bala State Road, Borth 580 31, 00- FSaat 222.0 feet to the point or place of BEGlldIM, `i Parcel Twot KI. that certaiss plat, piece or parcel of Land, with the baildin" i � and iaprovownts .kareou erected., taituats, lying and being in the ZttWn of sautJWld, County of £teffout ttrd State of NOW Yat'S1C, bouaded and described sea follmae SWIM Ka at a oom:rate &=vma tt an t1'w tsortherly lifts of ytin Road, at the eouthweratsrip conwr of land of Surro"hs,. saidi po...- also bet" the 0Imthv4-tarly c�orn.r of 14t 1, in a sub-division owned by 4 1\ Office am MA su r 539 cfrosizw said� int the of begk Coa>zj Claret-s � p � point of bsgLm3sgi ruMVIz4 tbeaee A"" Maid porthatlY liner Of Yalu Road, Booth SOP 311• ti; 00- Went 200.00 tants rmnaiztq thence Llozq tlw Iand of Robert Land] Jr e s North 240 47• SO` Ratst 22i.s1 feet to the soat1wrly line of lmv Island 7tai2ro1114 C�oa�tr►y t thine& &loop said lane of the Loc:g Inland Railroad Caatplmar:mcth 6e 04' 20- hast 199.09 fact to a ooarreta.aasnanssnt and•Raid--land:o[ tbgwa along said land of Bnritnnghs South 240 47' S0-'FAxt-1W.7a' feet to the pint or pi.0ae of MWIN iIN:,. • Ruameat� .. raftT imn: with a right of way easesant thirty feet in width over and aCrace the prani+ces of the party o f the first parts to be used for vehiculrr iagrss5 mA egress fret{ train State Road to the santherly portion of the preatmes herein conveyed to the party of the second Wt, said eammment being were particularly described as foliovsI flsdinsing at a point on,the southerly line of ?lain State Road, said point beiv* the following two eouraes and distances from the north- westerly career of land of party of the first part and the north- a+nsterly corner cd land isaercin conveyed to party of the second parte 1) North 'Sep 34- 00- Boat 133.26 feats 2) skmtk fie 31- p0- East 12.0 foot to the point of beginning, and the nrtotarly lint os said.30.0 casomati tannin theme dthi�h land of•party of the first part the following two amrswe and 1) South 190 4I• East 300.0 ftetj 2) Sloth 400 19- Mast 130.0 fiat, more or less, to said southerly portion of the prestimm herein conveyed to the..party of the aacod parts the easterly and aaathsaaterlp lines of said aaaaeent being 30.0 feat eantarly and eonthossterly from th-t above-described line. Reservations NEvniIMMSS, the party of the fir it part remarves onto itself the right to p71ss over and across the Jand conveyed to tba party of the v aeoctd part insofar as necessary to effectuate aainteaacce and re- pair or tbasa structures lying witMn ton feet or the vesterly side of the prapsrty of the first part. RECEDED AUG 0 �,"2 023 Zoning Boars] of Appeals i f� r77 'l�Ql t;•:to �Itsir.+�I.;. d meiaitat:A"O.p�!�?Pi,#�;of r .-1i�e:p i aa'aos ms�.a.as:aas pro shathe dK abosr dncrmed pftxthea te,uta testi Sols t me4 t66614=Wi3 tier iViittf3MXM need LII the tagte and trgbta of the[!si of tftc fiW pan kt atd m mrd psi TO RAVI AND TO Hf)I.D tlta preewn bertin Vwnj=so th*Ply ofrtbC•60�ttf.p�Wa ht'vrrOrAN •.'Y t000a+on and Larder:J the Pmy of the rtcood pati fcretta. �ro was conveyance is made in tuts usual mW rttplar courtso of busiatss ; actually conducted b¢ the party of the first part. i •r.. 'try"r?�3 •����'3i�iiiuG4�wn=�� .h.:$ ''�'^�D„��-�� t _• st: RECEIVE® AU 0 9 2023 �:',;,:.....•.:• ��. g as rd of Appeals AM!the peer of the fust put coreninu the. the party,of the first part hu not dmw er sowed anythhe ubmt 4 the twM pttxartea hire been ioctanberai in Lay.ray wfw ,secoept as afort w& AM the puts of the first part,in com;rbrim with Seuroe 13 of I&Lint Lite,oarmmu that the puny of the first past will reodro the conaeruion for this tonreyance and%ill In1d the Tkk to recd,c wch Meg& cation as a trust Land to be applied first for cite parpm of paying the m of ebe Leproramu and seryl apply the rime Etx tut tm pyytnent of the cast o!the Improvamm before uting any put of the roar of ibe tame for any otLtr pttepose.• . Tum ward"party aha?b::omatsed as if it Lead"Partici'whacrcr the sense of this indrotum so requires. IN VMIW83 Wpft;the fmtjr of the 6 tst pert ha:dnfy occaued this decd the day met year Drat above eaeittao. Tu tmccortz ars SC MMLD MARINE CEIRM IAXD RM CORP. . is• KLLM PqV4Y fG r' J. "Ii���AC1���Owsrd! w .q�ifiFfl/wtsM'.a�aiTdf .. .�•, W�`�! ►6Rfon aaw, Oct dc &Y d }A ►MOM at. PAY b sss Imm ft MSe Imarlded I q sod at* W tttc 1mCwa W be flat iadTidtsl duotibid i�•nd.Rlto �toc+f�R�r at+R , l c=artcd the t Few#ad rtknotrW04;tfq '�tFAl.:.�Ta4IE' 7liftiVSF: 'tii►X c., Bur "' COUNTY... NAU OP WN WOK COMM 49P SOMLK sa rrAT!(OF NM"a a' .all we Oa for rS M day of vecesber,l9 91,botoro sae t'lo tier day of 19 ,bilfam trn pe wwAy osose Killism P. Morris Pam-Ally ame w uw t'. Hio 6a b��r ew Visa.did a aad to aee lma�m.wlw,being by►ne duly-,M depou vw say that be teadea tl 7fIG t h0�) 1{altt 1 . any,dyl be rnidcs at Na sattbesldI w" York, bign, ; dw bo is dx Pre"dsat t he is the of SmLhoold Marias Center band Hold- wi ffie%■1 ant ed t5e tarce'?0" t the is s ad wlocb acaated the fot q;o�� kw"dw no of Iaid twpartstioo; flat the aw adirmd kom the serf of said wrpowim;tbtt the sat afssd to said ikstrtenestt is sgds tospors4e sv1;tbtt it first so to AM iertranxnt Is satb eorporste seal;that it-rtes so atrr,td 4 ordrr Of tlr-boa>d of djrtctor,cl aw oxpaa- tffw.d totf taw" the h &rcdors of bvi>3x RECEIVED tion, tore ba rtdnrd td«tstme tt r3e atski G A U 0 9 2023 ��Iilt;,��tr► I�:ac INSDRdKCE'Cilt1� �2 3cj sla u�,ke / Zoning Board of Appeals tam,Lraa�.ca ss°"'°'tssC. # ttlti lade�a Willi tAYtNAN7ACy11HSTG/,%Nf00.'tiG;lf =11M 056.00003.00 ti 006.110 •� Tml;ta _tier-60-s3 £Y' staci Sattbold Marime Ottakee Landfiald- Lor 016.000 i P/0 002.000 a itt0 Ctup. ota�orat mm 1000 ; sadd•s Pmd Maritsa, 1=. n.cam.aat AKAM CO Tea TMv 0001..Cwgdft srmtrr a srwo,sa •'•% sar.�ret+..snsrwswserwssw+.saMs Peksx' K. 110000 Fa4• i �GUAPANTFA• BZo#t Popd Road . Old Brookville, N. Y. rr N. 21545, wimwtaosw�str 0 W 7 t o r=LLI ,h i :a Planning, Zoni.ng.a.nd. P-Pl Impact Analysis June 2023 :~ Proposed Wireless Communications Faclfit,Y Albertson Marine 61405 Main Road Hamlet of Southold Town of Southold Suffolk County, flew York PREPARED FOR Elite'Towers,LP 1 South Durkee Lane East Patchogue,NY 11772 516.410.8730 PREPARED BY 100 Motor Parkway,Suite 350 Hauppauge,NY 11788 631.787.3400 Planning,Zoning and Visual Impact Analysis CZZOning D�o Proposed Wireless Communications Facility Albertson Marine 61405 Main Road Hamlet of Southold, Town of Southold Suffolk County, New York PREPARED FOR Elite Towers, LP 1 South Durkee Lane ���N (03 East Patchogue, NY 11772 \ 516.410.8730 PREPARED BY r b, �)91- q43 VHB Engineering,Surveying, Landscape > Architecture and Geology,P.C. 100 Motor Parkway Suite 350 Hauppauge, NY 11788 631.787.3400 June 2023 Planning,Zoning and Visual li Analysis Table of Contents 1 Introduction and Methodology...................................................................................................1 2 Existing Site Conditions and Proposed Wireless Communications Facility Design.................3 2.1 Existing Site Conditions....................................................................................................................................3 2.2 Proposed Wireless Communications Facility Design............................................................................4 3 Zoning, Land Use and Environmental Analysis...........................................................................6 3.1 Analysis of Town Code Requirements......................................................................................................12 3.1.1 Chapter 280,Article XVII—Wireless Communication Facilities..........................................12 3.2 Environmental Considerations.....................................................................................................................27 4 Visual Impact Analysis................................................................................................................28 4.1 Viewshed Analysis............................................................................................................................................28 4.2 One-Mile Visibility Study...............................................................................................................................30 4.3 Photographic Simulations.............................................................................................................................32 4.3.1 Methodology.........................................................................................................................................32 5 Findings and Conclusions...........................................................................................................37 RECEIVED AUG 0 9 2023 `7 'S 3� Zoning Board of Appeals i Table of Contents Planning,Zoning a -sual Impact Analysis List of Figures Figure No. Description Page Figure1 Site Location.............................................................................................................................................................2 Figure2 Existing Zoning........................................................................................................................................................9 Figure3 Existing Land Use..................................................................................................................................................10 Figure4 Viewshed Model....................................................................................................................................................29 Figure 5 One-Mile Visibility Study...................................................................................................................................31 Figure 6 Photosimulation Location Map.......................................................................................................................33 List of Appendices Appendix A Photographic Simulations Appendix B Verizon Wireless and Dish Wireless Plans Appendix C Alternative Sites Affidavit Appendix D Amato Law Group Letter, dated November 4, 2022 Appendix E Radio Frequency Reports for Verizon Wireless, Dish Wireless and Southold Fire Department Appendix F FAA Determination of No Hazard to Air Navigation Memo, dated December 12, 2022 Appendix G Antenna Site FCC RF Compliance Assessment and Report by Pinnacle Telecom Group Appendix H Determination from the New York State Office of Parks, Recreation and Historic Preservation Appendix I One-Mile Visibility Study Photographs RECEIVED AUG 092023 Zonin ?3 7 9 Board of APPeals ii Table of Contents Planning,Zoning and Vi mpact Analysis e h bo, 00 qm V RECEIVED AUG.0 9 2023 `7 8 a1 Zoning Boar Introduction and Methodology dof�ppea's VHB Engineering, Surveying, Landscape Architecture and Geology, P.C. (VHB) has prepared a Planning,Zoning and Visual Impact Analysis for the proposed wireless communications facility (the"Proposed Facility'),to be installed at 61405 Main Road (New York State Route 25) in the hamlet of Southold,Town of Southold, Suffolk County, New York(Figure 1).The 0.95±-acre overall Subject Property is designated on the Suffolk County Tax Map as District 1000—Section 056.00—Block 03.00—Lot 015.000.The Proposed Facility consists of the installation of a 150±- foot above grade level (agl) concealment pole with the antennas of multiple wireless service carriers within, Southold Fire Department antennas mounted atop the pole to a top height of 164-feet-10± inches agl, and an associated ground-based equipment compound. The Subject Property was examined with respect to land use and zoning, environmental conditions and visual resources.An investigation of the area (performed on April 11, 2023) and review of aerial photography was performed to examine land use on the site and in the surrounding community. Photographs were taken to document the existing land uses on the site and in the surrounding area (see Sections 2 and 3, below).Additionally,the Town of Southold (the "Town")zoning map was reviewed to determine the zoning of the site and surrounding area. Town Code provisions regulating the installation of wireless communications facilities were also analyzed. In order to conduct the visual analysis, the following methodology was employed: > Visual inspection of the Subject Property and evaluation of physical characteristics of the Proposed Facility design > Visual inspection of surrounding areas to determine existing characteristics and obstructions in the visual horizon, as well as the potential visibility of the top.of the Southold Fire Department antennas atop the concealment pole as represented by a flag affixed to a crane at the maximum height of the Proposed Facility (i.e., 164-feet-10± inches agl) > Preparation of a viewshed map to model visibility of the proposed concealment pole throughout the surrounding area within a one-mile radius, including views from private properties and roadways; and > Evaluation of photographic simulations of the Proposed Facility, prepared by VHB, dated May 2023 (Appendix A) 1 Introduction and Methodology Figure 1: Site Location Ob. Proposed Wireless Communications Facility -Albertson Marine 61405 Main Road, Hamlet of Southold, Town of Southold, Suffolk County, New York SCTM No.: District 1000—Section 056.00—Block 03.00—Lot 015.000 I \ Proposed iiIWireless Communications Facility pld Main{to ad _5 �O -• t Subject Property • as, �o � a o� Q aa5 Suffolk County N ' 1 0 100 200 300 Feet Q Subject Property* RECEIVED AUG 0 9 2023 'Subject Property boundaries are approximate. .—� �?-3 Source Suffolk County Real Property Tax Service Agency(2016). Nearmap Imagery(2023) Zoning Board of Appeals 2 Planning,Zoning and V,` mpact Analysis RECEIVED AUG 0 9 2023 Zonin 7 9 3 g Board of Appeals Existing Site Conditions and Proposed Wireless Communications Facility Design 2.1 Existing Site Conditions The 0.95±-acre Subject Property is currently improved with a boat storage warehouse with associated paved areas surrounding the warehouse that are used for outdoor boat storage by Albertson Marine.The adjacent parcel to the west contains a building with a sales floor, offices and a maintenance facility, as well as additional outdoor boat storage and parking areas, also used by Albertson Marine.The adjacent parcel to the east contains additional paved areas for outdoor boat storage.The Long Island Rail Road (LIRR)tracks adjoin the Subject Property to the north. Main Road adjoins the Subject Property to the south. The Subject Property is situated within an area of the hamlet of Southold characterized by a mix of suburban residential,waterfront, commercial, agricultural and open space land uses found throughout the North Fork of Long Island. Due to the location of the Subject Property along a mixed-use corridor near the waterfront of Budds Pond/Shelter Island Sound as well as single- family residential neighborhoods and open space,the visual horizon in this area varies.Along Main Road,there are utility poles with overhead wires, marinas with boat docking facilities and large commercial structures, and undeveloped,vegetated areas. Farther out from the Subject Property,there are one-to-two-story single-family homes in densely vegetated neighborhoods interspersed with agricultural and vegetated undeveloped areas. Utility poles with overhead wires are present along certain residential streets throughout the area. The photographs below depict the existing conditions at the Subject Property.Additional photographs depicting the surrounding area are included in Section 3, along with a detailed description of the land uses surrounding the Subject Property. 3 Existing.Site Conditions and Proposed Wireless Communications Facility Design Planning,Zo and Visual Impact Analysis View of the overall Subject Property from Main Road,facing View of the Proposed Facility location at the rear of the northeast. Subject Property,facing northeast. 2.2 Proposed Wireless Communications Facility Design The Proposed Facility includes the installation of a 150±-foot above grade level (agl) concealment pole with the antennas of multiple wireless service carriers concealed within and two Southold Fire District whip antennas mounted atop the concealment pole reaching a top height of 164-feet-10±-inches agl. Six Verizon Wireless panel antennas would be installed within the concealment pole in three sectors (two panel antennas per sector) at centerline heights of 141-feet-2± inches agl and 146-feet-1± inch agl.Three Dish Wireless panel antennas would be installed within the concealment pole in three sectors (one panel antenna per sector) at a centerline height of 132± feet agl.There would be room for additional future wireless service carrier antennas within the concealment pole below the Verizon Wireless and Dish Wireless antennas. The concealment pole would be installed within a 70±-foot-by-35±-foot (2,450±-square-foot [sf]) ground-based fenced equipment compound situated at the rear(north) side of the Subject Property behind an existing boat storage warehouse.The equipment compound would include space for the equipment of multiple wireless service carriers (i.e., Verizon Wireless, Dish Wireless �FT�tF� and future carriers), and the Southold Fire District. RE CF,\I The Verizon Wireless equipment would be installed atop a proposed 10±-foot-by-20±-foot pU6 0 9 2023 (200±-sf) steel platform surrounded by a 42±-inch-high handrail, and would be covered by a eals teel canopy with a top height of 11-feet-6± inches agl. Four Verizon Wireless GPS units would Zoning a mounted atop the equipment canopy to a top height of 13-feet-6± inches agl. The Dish Wireless equipment would be installed atop a proposed 8±-foot-by-10±-foot (80±-sf) steel platform surrounded by a 42±-inch-high handrail. One Dish Wireless GPS unit would be mounted atop the equipment platform. The Southold Fire District equipment would be installed atop a proposed 8±-foot-by-10±-foot (80±-sf) equipment platform. The equipment within the compound would be connected to the concealment pole via cable bridges (one cable bridge per equipment platform).Additionally, utility connections (i.e., power and telco)would be routed underground from an existing utility pole on Main Road to a 4 Existing Site Conditions and Proposed Wireless Communications Facility Design Planning,Zoning and V Impact Analysis proposed transformer and mesa cabinet within the equipment compound. Power and telco conduits would be routed underground within the equipment compound from the transformer and mesa cabinet to the equipment platforms. All equipment within the.compound would be elevated a minimum of 3± feet agl to provide a minimum of two feet of clearance above the base flood elevation of six feet (North American Vertical Datum of 1988). The equipment compound would be surrounded by a 6±-foot agl black chain link fence with an access gate on the east side of the compound. Evergreen trees with a minimum height of 6± feet agl would be planted in a staggered pattern along the north and west sides of the compound to 'provide additional screening.. The plans depicting the Proposed Facility, dated June 15, 2023 (for Verizon Wireless) and June 21, 2023 (for Dish Wireless), prepared by Azimuth Engineering, are provided in Appendix B. RECEIVED AUG 0 g 2023 Zonin -7 2 3 g Board of,Qppeals 5 Existing Site Conditions and Proposed Wireless Communications Facility Design Planning,Zoning and Vi mpact Analysis RECEIVED AUG 0 9 2023 -7'83 [Zoning Board of Appeals 3 Zoning, Land Use and Environmental Analysis According to the Town of Southold Zoning Map (Section 2 of 4),the Subject Property is situated within the Town's Marine II (MII)Zoning District(Figure 2). Pursuant to § 280-55 of the Code of the Town of Southold (the"Town Code"), permitted uses within the MII District include single- family residences; marinas; boat docks, slips, piers or wharves; beach clubs,yacht clubs or boat clubs; boatyards for building, storing, repairing, renting, selling or servicing boats; mariculture or aquiculture operations or research and development; boat and marine engine repair and sales and display,yacht brokers or marine insurance brokers; public facility(i.e.,Town, school districts, park districts and fire districts) uses; and retail or rental of fishing, diving or bathing supplies and equipment. Customary accessory uses to these primary uses are permitted subject to Site Plan review.The MII District also permits various uses by special exception from the Zoning Board of Appeals (ZBA), including restaurants;ferry terminals;transient hotels or motels;fish processing plants;fish markets; museums with a nautical theme or art galleries; and bed-and-breakfasts. As discussed above,the Subject Property is currently developed with a boat storage and maintenance facility known as Albertson Marine, containing a metal warehouse and paved areas used for outdoor boat storage.The adjoining parcels to the west and east are also part of the Albertson Marine operations, containing another building with a sales floor, offices and a maintenance facility, as well as additional outdoor boat storage and parking areas.Albertson Marine operates a marina to the southeast of the Subject Property, across Main Road.The zoning classifications and land uses within approximately one-quarter-mile surrounding the Proposed Facility location are described below. North:The area north of the Subject Property is in the R-80 (Residential Low-Density,two-acre minimum) District and contains the LIRR tracks directly north of the Subject Property,followed by open space land,single-family residences and agricultural land. East:The area east of the Subject Property is in the R-80 District (north of the LIRR tracks) and MII district(south of the LIRR tracks). On the north side of Main Road, in the MII District,there is property used by Albertson Marine for outdoor boat storage,vacant land (e.g., undeveloped and a former restaurant), open space, and another boat storage facility(outdoor and warehouse). On the south side of Main Road, east of the Subject Property,,are marinas, including Albertson Marine and Port of Egypt.These.marinas feature piers and docks in Budds Pond with associated commercial facilities, such as lodging, boat sales and service, and restaurants. 6 Zoning,Land Use and Environmental Analysis Planning,Zc and Visual Impact Analysis South: Main Road is immediately south of the Subject Property, followed by open space bordering Budds Pond in the MII District.There is a single-family residential neighborhood to the southwest of the Subject Property within the R-40 (Residential Low-Density, one-acre minimum) District. West: The Albertson Marine maintenance/sales/office building and parking lot are immediately west of the Subject Property,within the MII district.This facility is followed by agricultural and single-family residential properties within the R-80 District (north of Main Road). As described above, the Subject Property is located in an established suburban neighborhood with a character that varies from marine-centric along the waterfront, to traditional single-family subdivisions, with agricultural uses and open space interspersed throughout.The photographs below are representative of the surrounding area.The zoning classifications and land uses described above are depicted on Figure 2 and Figure 3, respectively. Y Outdoor boat storage immediately east of the Subject A marina to the southeast of the Subject Property on Main Property on Main Road,facing north. Road,facing southeast. 14T- -' Another boat storage area(outdoor and warehouse)along View of open space south of the Subject Property across Main Road, east of the Subject Property,facing northeast. Main Road,facing south. [Zoning EIVED 0 9 2023 B31 7 Zoning,Land Use and Environmental Analysis rd of Appeals Planning,Zoning and V mpact Analysis dam View of agricultural and residential land west of the Subject View of a single-family residential neighborhood southwest Property along Main Road,facing southwest of the Subject Property along Budds Pond Road,facing northeast RECEIVED 1AUG 0 9 2023 Zoning B�a d gppeals View of a single-family residence northwest of the Subject Property along Park Avenue,facing northwest 8 Zoning,Land Use and Environmental Analysis Figure 2: Existing Zoning Vhb. Proposed Wireless Communications Facility - Albertson Marine 61405 Main Road, Hamlet of Southold, Town of Southold, Suffolk County, New York SCTM No.: District 1000—Section 056.00— Block 03.00—Lot 015.000 Opp, a _ s ftwft Ole v Proposed Wireless L R—n O Communications Facility a o\N 1, i o I 9� 0, � m c i \ I w M I I �e o� � y as , ca / ` Qo R-40 d 0 !\ / A da �oaa /IV� 0 250 500 Feet RECEIVED \ \ Q Subject Property* • AUG 0 9 2023 Proposed Facility Location 7 '�3� r J Quarter-Mile Radius Zoning Board of Appeals QZoning District Boundaries(approximate) Tax Parcels *Subject Property boundaries are approximate. Source:Zoning District boundaries digitized based on Town of Southold Zoning Map Section 2 of 4(2004); Tax Parcels from Suffolk County Real Property Tax Service Agency(2016) 9 Figure 3: Existing Land Use vhb. Proposed Wireless Communications Facility- Albertson Marine 61405 Main Road, Hamlet of Southold, Town of Southold, Suffolk County, New York SCTM No.: District 1000—Section 056.00— Block 03.00—Lot 015.000 i / ' Proposed Wireless Communications Facility ` oad O\a�a d o• O A 01 d N7 4.04 GP I I ' .yh �e 0J as , �o a � �JDah / ` �ytiO as � N �ROaa vj�U°,N II 0 250 500 Feet Subject Property* Commercial ID Proposed Facility Location Recreation&Open Space r J Quarter-Mile Radius Agriculture Vacant EZoniing EIVED Low Density Residential (_< 1 unit per acre) I Medium Density Residential (>1 to < 5 units per acre) Transportation 0 9 2023 . High Density Residential (>_5 units per acre) Surface Waters 3 7 rd O ,_ *Subject Property boundaries are approximate. Source Suffolk County Land Use(2016) 10 Planning,Zc and Visual Impact Analysis From a land use planning perspective, the installation of the Proposed Facility is appropriate as it utilizes a commercial property situated along a heavily traveled roadway adjacent to the LIRR and commercial marine uses,with large buildings and overhead utilities as part of the visual landscape. By co-locating the antennas of multiple wireless service carriers and the Southold Fire Department on a single concealment pole, the Proposed Facility would comply with the Town Code by limiting the need for future installation of multiple communications facilities to serve the area lacking sufficient coverage.This is beneficial from a land use planning perspective, avoiding the potential proliferation of similar facilities, and would reduce potential associated impacts, such as visual impacts.As discussed in detail in Section 4, the visual analysis demonstrates that, although the Proposed Facility would be visible from some parts of the surrounding area, visibility is obscured from many vantage points throughout the surrounding area by existing structures, vegetation and area topography. Furthermore, the concealment design and neutral coloration of the pole will minimize visual impacts from views where the pole can be seen. Another mitigating design consideration is the positioning of the base of the pole and equipment compound in an area behind the existing warehouse on the Subject Property, adjacent to the LIRR tracks, and surrounded by fencing and evergreen vegetation, screening the base of the pole and equipment compound from the surrounding area. =Board 11 Zoning,Land Use and Environmental Analysis Planning,Zoning and V mpact Analysis Fv21ttJ*hftJ.9YtPo EIVED 3.1 A���fl�fsis of Town Code Requirements 9 2023 3cArticle XVII of the Town Code regulates wireless communications facilitief Appeals Pursuant to § 280-70.13,the Proposed Facility requires site plan approval, approval and a building permit. In addition,the Proposed Facility requires waivers from the Planning Board per§§ 280-76.2(A), (B), (C) and (E) regarding the criteria in §§ 280-70.1(2) and (3) and §§ 280-72.A(6) and (9).As set forth at§ 280-70.G,the Co-Applicants are seeking a relaxation of the minimum fall zone requirement.As set forth at § 280-76.3,the Co-Applicants are also seeking variances from the ZBA for minimum lot.size and rear yard requirements.A consistency analysis of the Proposed Action with the relevant Town Code requirements is presented below. 3.1.1 Chapter 280, Article XVII — Wireless Communication Facilities §250-70—General Requirements for All Wireless Communication Faclities D. Location of wireless facilities. 7) Applicants for wireless communications facilities shall locate,site and erect said wireless facilities in accordance with the following priorities, of the lowest priority. a) On an existing antenna support structure or other structures on Town-owned properties, including the right-of-way. b) On an existing antenna support structure or other structures on other property in the Town. c) A new antenna support structure on Town-owned properties. d) A new antenna support structure on properties in the LI or L10 Zoning Districts. e) A new antenna support structure on properties in the Ml, Mll, B or HB Zoning Districts. fl A new antenna support structure on properties in the AC, R-40, R-80, R-720, R-200, R-400, LB, RO, RR, HD or AHD Zoning Districts. The Proposed Facility is consistent with this standard, as it involves the installation of a new concealment pole on a property in the MII District.A site that would meet the coverage objectives of the Proposed Facility is not available on an existing structure, on a Town-owned property, or in the LI or LIO Districts.As discussed in more detail below,the Alternative Sites Affidavit attested by Ms.Tanya Negron of Elite Towers, dated October 31, 2022 (Appendix C), discusses the selection process for the Proposed Facility location as the best available site. 2) If the proposed site is not proposed for the highest priority listed above, the applicant shall submit a written report demonstrating the applicant's review of the above locations in . order of priority, demonstrating the technological reason for the site selection. If appropriate, based on selecting a site of lower priority, a detailed written explanation as . to why sites of a higher priority were not selected shall be included with the application. The applicant seeking such an exception must satisfactorily demonstrate the reason or i reasons why such a permit should be granted for the proposed site, and the hardship that would be incurred by the applicant if the permit were not granted for the proposed site. 12 Zoning,Land Use and Environmental Analysis Planning,Zo and Visual Impact Analysis As indicated in the letter submitted by Amato Law Group, dated November 4, 2022 (Appendix D), Priorities A and B have been ruled out because "no existing support structures would be able to provide sufficient coverage to satisfy the need in this area" (ALG, page 2). Priority C has also been ruled out because"no Town-owned parcels were available that would be situated within the area to service the existing coverage gap." (ALG, page 2). Priority D,which includes properties in the LI or LIO'Districts, has been ruled out because "there are no such facilities in the vicinity of the Property,which is the target location to serve the needs of the co-applicants DISH and Verizon Wireless. Further, enclosed as part of this submission is Elite's Alternative Sites Affidavit, consisting of a report demonstrating an explanation as to each of the other sites which were investigated, and why they were ultimately rejected as viable alternatives" (ALG, page 2).Thus, the Co-Applicants have selected a viable location with the highest available priority level to address the existing signal deficiencies. 3) An applicant may not bypass sites of higher priority by stating the site proposed is the only site leased or selected.An application shall address,co-location as an option. If such option is not proposed, the applicant must explain to the reasonable satisfaction of the Planning Board why co-location is commercially or otherwise impracticable.Agreements between providers limiting or prohibiting co-location shall not be a valid basis for any claim of commercial impracticability or hardship. Higher priority sites have not been bypassed for the sole reason of the Subject Propertybeing the only site leased or selected.As indicated in the Alternative Sites Affidavit(Appendix C), potential sites for the Proposed Facility were evaluated "based upon a need to remedy service deficiencies in a specific geographic area" (Alternative Sites Affidavit, paragraph 4).The search for potential sites is supported by radio frequency(RF) reports commissioned by the wireless carriers to identify the extent of the existing service deficiency and the location of potential suitable sites to remedy the service deficiency, including the locations of existing facilities for potential co- location (Appendix E).These RF reports provide the technical basis for the selection of the Subject Property as the most suitable'site to remedy the established service deficiency gap.The Subject Property was selected as the most suitable site for the Proposed Facility based on the lack of availability of other higher priority sites within the area that would still address the service deficiency gap. Based on the above, the Proposed Facility is consistent with this requirement. E. Guyed or lattice antenna support structures are prohibited. The Proposed Facility is a concealment pole, not a guyed or lattice tower.Therefore,the Proposed Facility would be consistent with this standard. F. Antenna support structures shall not be located in the following areas without a permit from all jurisdictional agencies: 4) Wetlands, tidal and freshwater. 5) Land above high groundwater(within 10 feet of the surface). RECEIVED 6) Lands purchased with Community Preservation Funds. AUG U 9 2023 7) Coastal erosion hazard areas. 7 9 3� 8) Designated parkland. Zoning Board of Appeals With respect to tidal and freshwater wetlands, as shown on the Vicinity Plan (Sheet Z-06 in Appendix B), based on a wetland delineation by VHB on March 29, 2023,there are no tidal or 13 Zoning,Land Use and Environmental Analysis Planning,Zoning and V; mpact Analysis freshwater wetlands within the Proposed Facility location on the Subject Property. It is noted that the Proposed Facility location is within the limits of the NYSDEC's and Town of Southold's freshwater wetlands regulatory jurisdiction (i.e.,within 100 feet upland of the wetland boundaries).Therefore,the Applicant will secure freshwater wetlands permits from the NYSDEC and the'Town of Southold prior to construction of the Proposed Facility. With respect to groundwater elevation, a review of the U.S. Geological Survey's Long Island Depth to Water Viewer indicates groundwater is expected to be encountered at depths of less than 10 feet below grade surface (bgs). Site-specific depth to groundwater will be confirmed prior to construction and appropriate construction methods will be selected based on the results of these investigations. The Subject Property is not located in any other of the above-listed aeras and,therefore, does not require any additional permits in connection with agency jurisdiction over such areas. G. Fall zones.An antenna support structure must include an area surrounding it that is free of other structures and areas where people congregate, except the base equipment, with a radius equal to a distance of two times the height of the structure.A smaller fall zone may be allowed if supported by a report submitted by a qualified structural engineer. The structural engineer's report shall be submitted to and reviewed by the Planning Board and corroborated by an independent consultant hired by the Town that demonstrates that a smaller fall zone is appropriate and safe. The fall zone of an antenna support structure must not include areas where people congregate, and must be clear of all structures except the base station equipment. As the proposed concealment pole (i.e.,the antenna support structure)would have a top height of 150± feet agl,the required fall zone would include a 300-foot radius around the base of the pole.The Proposed Facility would not meet this requirement because,as shown on the Vicinity Plan (Sheet Z-06 in Appendix B),the required 300-foot fall zone contains two existing structures associated with the operations of Albertson Marine, Long Island Rail Road tracks, Main Road, a portion of a marina, and open space areas.Therefore, as set forth at§280-70.G, relief is required from the Planning Board to allow a smaller fall zone. Under separate cover,the Co-Applicants will submit a report prepared by a qualified structural engineer,for review by the Planning Board, attesting to the integrity of the pole design consistent with the provision of this standard allowing for a reduced fall zone. H. Federal aviation regulations.All wireless facilities shall comply with applicable airport and/or air space hazard and/or obstruction regulations.Any facility that would be classified as an obstruction or hazard under current federal aviation regulations or would otherwise interfere with the operation of radio navigation aids, communications and/or airport operations is prohibited. Enclosed is a "Determination of No Hazard to Air Navigation" memorandum issued by the Federal Aviation Administration (FAA) on December 12, 2022, for the Proposed Facility(Appendix F). L Antenna support structures in the Ll, LIO, Ml, MII, B, and HB Zoning Districts are subject to the following restrictions: 1) Minimum lot size:in accordance with the bulk schedule for each zone. 2) Maximum height.80 feet. RECEIVED ALIP 0 9 �73 14 Zoning,Land Use and Environmental Analysis .� Zoning 13r, fs; =,ls Planning,Zo and Visual Impact Analysis 3) Minimum distance of all wireless equipment to adjacent residential property lines or streets shall be no less than 500 feet. The Applicant is seeking variances/waivers from the minimum lot size, maximum height and minimum distance to residential property lines or streets requirements set forth above. The minimum lot size requirement in the MII District is 80,000 sf per use.The Subject Property is 41,346± sf, and would contain two uses, including the Proposed Facility and the existing Albertson Marine boat storage and maintenance operation.Therefore,there is a minimum lot size of 160,000 sf for two uses on the Subject Property, and a variance is required from the Town ZBA. It is noted that the requirements of the MII District are primarily intended to govern commercial maritime uses, such as marinas, boat docks, yacht clubs and boat yards,which would normally be expected to require larger lot areas due to the nature of the activities involved in commercial maritime uses.While the Subject Property is 41,346± sf, it is contiguous with additional parcels to the east and west that fall under the same operations of Albertson Marine (i.e., District 1000— Section 056.00—Block 03.00—Lot 013.004 [1.13± acres] and Block 04.00— Lot 001.000 [0.45± acre]), such that the total contiguous acreage operated by Albertson Marine is approximately 2.53± acres (110,200± sf),' which is well above the minimum lot size requirement of 80,000 sf for two uses. Furthermore,the Proposed Facility requires a relatively small area to operate (i.e., 0.06± acre), as it is unmanned with minimal temporary parking needs, and has equipment and the concealment pole contained within a fenced compound.As such,there is sufficient overall area for the Proposed Facility to operate without interfering with the existing operations of Albertson Marine and the granting of a variance from the minimum lot size requirement would not result in significant adverse impacts. The Proposed Facility would require a.waiver from the Planning Board, per§280-76.2A of the Town Code,to permit the installation of a 150±-foot-tall concealment pole (with Southold Fire Department antennas reaching a top height of 164-feet-10± inches agl)where a maximum height of 80 feet is allowed. Although the Proposed Facility would exceed the height standard, the requested height is required in order to address the wireless service deficiency in the area, as demonstrated in the RF reports included in Appendix E:Additionally, as discussed in the letter prepared by Integrated Wireless Technologies (IWT)for the Southold Fire District(Appendix E) dated October 24, 2022, "the additional tower is required to provide a public safety quality of communications service in areas frequented by the Fire District... 150 [feet] is required to provide coverage at levels acceptable for Public Safety communications systems and ensure the ability for the fire fighter to communicate during critical calls" (IWT, paragraph 1). Moreover, in addition to the Southold Fire Department,Verizon Wireless and Dish Wireless,the Proposed Facility would be able to accommodate the co-location of additional wireless communication providers, thereby obviating the potential need for an additional structure in the future. The Proposed Facility would also require a waiver from the Planning Board, per§ 280-76.213 of the Town Code,to allow the siting of the Proposed Facility within 500 feet of an adjacent residential property line or street.The Proposed Facility would be situated a minimum of eight± feet from the northern property line, which coincides with a transition to the R-80 residential Adjacent parcel acreages as listed on the Town of Southold"Tax Map Inquiry"online map,available JOE httDS:/'tOS.n"la)s.ai-cgis.coiii/ao s Solutions/s2.html?a� id=lb4d46la4ebc4401r19d25e98eb3fa 0. CEIVED AUG 092023 Zoning Boa 15 Zoning,Land Use and Environmental Analysis f2PPeals Planning,Zoning and V Impact Analysis zoning district. However, beyond this property line is a transportation use (i.e.,the LIRR corridor), followed by open space to the north, and there are no residential structures within 500 feet of the Proposed Facility. Despite the placement of the Proposed Facility within 500 feet of the nearest residential property line,the site has been chosen to be the least obtrusive feasible, in the rear portion of the Subject Property, near the LIRR right-of-way and surrounded by commercial marine uses and open space. Moreover, it is noted that wireless service antennas would be concealed within the pole, which would be painted a neutral color thereby mitigating potential visual impacts:Furthermore, under separate cover,the Co-Applicants will submit a report prepared by a qualified structural engineer,for review by the Planning Board, attesting to the.integrity of the pole design.Thus, given the limitations of the existing site configuration, which is the only viable location for the Proposed Facility to address the coverage deficiencies of the Southold Fire Department,Verizon Wireless and Dish Wireless,the placement of the Proposed Facility at the rear of the Albertson Marine property is appropriate,despite the need RECEIVED r waivers. Radio emissions must fall within the maximum permissible exposure(MPE) limits established AUG 0 9 2023 by the FCC... [Zoning Board of A he Proposed Facility would comply with all applicable FCC regulations as attested in a report by ppeals innacle Telecom Group, dated August 22, 2022 (Appendix G), and thus, is consistent with this standard. L. At the request of the Building Inspector, owners of wireless facilities shall provide a structural inspection report prepared by a structural engineer which verifies the structural integrity of the wireless facility and any associated antenna support structures. As indicated above,the Co-Applicants will submit a report under separate cover which details the evaluation of the Proposed Facility by a structural engineer, consistent with this standard. M. No antenna support structure shall be constructed at, or remain at, a height that is taller than that required by installed and operational antennas. The proposed concealment pole would be 150 feet agl, which, based on the RF reports in Appendix E, is the minimum height necessary to address the existing service deficiencies of Verizon Wireless, Dish Wireless and the Southold Fire Department in the area of the Subject Property.Thus,the Proposed Facility is consistent with this standard. N. Site Design standards.All wireless facilities, including co-locations,.shall be the least visually obtrusive design possible that also permits the applicant to achieve its service needs. To that end, the following design standards shall apply to all wireless communication facilities installed or constructed pursuant to the terms of this chapter: 1) Setbacks.Antenna support structures and equipment shall adhere to the setbacks for principal uses in the Bulk Schedule applicable to the zone in which the structures are located, unless otherwise indicated elsewhere in this chapter. The Proposed Facility would comply with the minimum front and side yard setbacks of 35 feet and 25 feet in the MII District, respectively, but requires a variance for a rear yard setback of eight± feet (to the equipment compound),where the requirement is 25 feet in the MII District. The proposed equipment compound would be located a minimum of eight± feet from the northern property line at the rear of the Subject Property, which adjoins the LIRR corridor. However, by locating the equipment compound at this position, it would be screened from views 16 Zoning,Land Use and Environmental Analysis Planning,Zo 3nd Visual Impact Analysis along Main Road by the existing boat storage warehouse on the Subject Property. Furthermore, as the area north of the compound contains LIRR tracks and wooded open space,,there are no uses that would be disturbed by the presence of the equipment compound within the required rear yard setback. Nevertheless, the proposed equipment compound would be surrounded by a six-foot-tall black chain-link fence and evergreen trees to create additional screening of the equipment compound and the base of the concealment pole. Finally, it is noted that the proposed concealment pole itself would meet all MII District setback requirements, situated a minimurri of 30± feet from the rear property line. 2) ; Signs. Signs shall not be permitted on facilities except for signs displaying contact information and safety instructions, which are required. Safety signs shall be in accordance with American National Standards Institute (ANSI)standards for radio frequency radiation warning signs. Contact signs shall identify all service providers on the facility and shall.include normal and emergency contact information for each. Such signs shall not exceed five square feet in surface area. No signage is proposed for the Proposed Facility, other than contact information and safety instructions, as required by law.The signage would include all information requested above and would not exceed five square feet in surface area, in compliance with this criterion. 3) Base station equipment shelter. The base station equipment shelter shall be constructed with a finish similar to that of adjacent structures on the property and integrated into the architectural style.Any newly constructed base equipment shelter shall be located in RECEIVED accordance with the minimum height and yard requirements of the zoning district applicable to the site, and up to two adjacent off-street parking spaces may be provided AUG O 9 2023 for service vehicles. Notwithstanding the foregoing, base equipment related to interior- 3� mounted wireless facilities shall be located in an area that is satisfactory to the Planning Zoning Board of Appeals Board upon consideration of impacts on adjacent properties and minimizing visual impacts. The Proposed Facility involves the installation of a concealment pole within a fenced equipment compound,which does not include the installation of a base station equipment shelter, but rather, involves the installation of wireless service carrier and Southold Fire Department equipment upon steel platforms, and utility connection equipment on H-frames (Mesa cabinet to be installed on H-frame within the compound and transformer and meters to be installed on H- frame and immediately outside the compound). Given the existing visual character of the Subject Property,which includes a large boat storage warehouse and outdoor boat storage, it is not expected that the proposed equipment compound would significantly impact the visual character of the Subject Property or surrounding area. Furthermore, the position of the equipment compound at the rear of the boat storage warehouse would obscure the compound from views along Main Road, and supplemental evergreen landscaping would be planted around the compound.Thus,visual impacts would be minimized and the Proposed Facility is consistent with this standard. 4) Base equipment landscaping.A screen of evergreen trees shall be planted outside,the fence of the base equipment area or shelter to provide a visual screen or buffer for adjoining private properties and the public right-of-way or other vantage points accessible to the public. The screen shall consist of a double row of evergreen shrubs and trees that are of sufficient density and height to immediately screen the base equipment from view. Required front yard setback areas shall be landscaped and include shrubs and 17 Zoning,Land Use and Environmental Analysis Planning,.Zoning and Vi mpact Analysis trees. Survivability of the landscaping shall be guaranteed and maintained by the applicant for the life of the installation. As shown on the Compound Plan (Sheets Z-08 and A-1C in Appendix B),the Proposed Facility would provide landscaped screening at the base of the equipment compound, consistent with this standard. Specifically, evergreen trees, a minimum of six-feet-tall,would be planted in a staggered pattern along the northern and western perimeter of the equipment compound, as well as at the southeast corner of the equipment compound.While these trees would provide vegetative screening, it should be noted that the position of the equipment compound at the rear of the Subject Property would also serve to limit its visibility from surrounding areas.The equipment compound would be situated behind a large boat storage warehouse, blocking views of the compound from Main Road.The area immediately north of the Subject Property,which already has views to the outdoor boat storage area and warehouse on the Subject Property, contains LIRR tracks and wooded open space, such that there would only be brief, infrequent views of the compound from the north by LIRR passengers. 5) Site lighting. The lighting permitted shall be the minimum required to protect the public welfare. Facilities sited on existing developed sites shall be incorporated into the lighting plans of those sites. Outside lighting shall use fully shielded factures so that the light source is not visible from beyond the property line, and no light is reflected or shone towards the sky, except in the case of structures required to follow FAA guidelines for safety lighting. As shown on the Equipment Plan (Sheet Z-09 in Appendix B) and Equipment Platform and H- Frame Details (Sheet A-3 in Appendix B)the equipment platforms for Verizon Wireless and Dish .Wireless would include work lights for use by maintenance personnel. Details of the work lights are also provided on Sheets Z-12 and A-4 in Appendix B.These lights would be directed only onto the equipment platforms and would be timed to turn off upon completion of maintenance. The fixtures would not shine onto adjacent properties, consistent with this standard. §280-77-Required Approvals All wireless communications facilities, and modifications to such facilities shall require a building permit, site plan approval, and special exception approval, except those meeting certain requirements... The Proposed Facility requires a building permit, site plan approval and special exception approval, and applications for such approvals would comply with the general requirements for all wireless communications facilities and the applications requirements, as set forth in § 280-70 and § 280-74 of the Town Code, respectively.Thus, the Proposed Facility is consistent with this standard. §280-72-Site Plan Approval A. Standards. In addition to the standards in Article XXIV and the standards in §280-70 herein, all wireless facilities, including co-locations,shall be the least visually obtrusive design possible that also permits the applicant to achieve its service needs. To that end, the following design standards shall apply to all wireless communication facilities installed or constructed that require site plan approval: 7BOarcj ('�; 18 Zoning,Land Use and Environmental Analysis Planning,Zc 3nd Visual Impact Analysis 1) Camouflage on buildings. Wireless antennas, if mounted on a building fagode, shall be flush-mounted and painted or otherwise treated to blend with the fagade. When a wireless communication facility extends above the roof height of a building on which it is mounted, every effort shall be made to conceal the facility within or behind existing architectural features to limit its visibility from public and residential vantage points,yet . ; ,.. !ED permit the facility to perform its designated function. Facilities mounted on a roof shall be AUG O 9 2023 stepped-back from the front fagade in order to limit their impact on the building's 3� silhouette. If antennas are part of the stepped-back facility, the applicant shall submit an Appeals access control plan that precludes inadvertent access to the front faces of the antennas by Zoning Board of App building workers and the general public. The wireless communication facilities shall blend in with the existing building's architecture and shall be painted or shielded with material which is consistent with the design features and materials of the building. The Proposed Facility does not include the mounting of antennas upon a building.Therefore, this standard is not relevant. However, it is noted that the Proposed wireless carrier antennas would be concealed within the pole painted a neutral color to blend in with the sky and other background conditions.While the proposed Southold Fire Department whip antennas would be visible atop the proposed concealment pole,they would have a slender profile and are not out of character with other existing emergency services communications antennas found in the Town along Main Road, including at the Southold Fire Department, 1.16± miles southwest of the Subject Property, and"at the Southold Police Department, 3.64± miles southwest of the Subject Property.Associated equipment would be installed within the proposed ground-based,fenced equipment compound which would include supplemental evergreen screening.Thus,the Proposed Facility would be as visually unobtrusive as possible. 2) Access.Access to wireless facilities shallbe from already established site access points whenever possible. Access to the Proposed Facility would be from existing site access driveways on Main Road.Thus, the Proposed Facility complies with this standard. 3) Dish antennas. Dish antennas shall be colored, camouflaged or screened to the extent that they are as unobtrusive as possible, and in no case shall the diameter of a dish antenna exceed six feet. The Proposed Facility does not include dish antennas.As such,this standard is not applicable. 4) Electric line setback. Except for wireless facilities specifically designed for mounting on electric transmission towers, or within the footprint of such towers, no wireless communication facility shall be located nearer to any overhead electric transmission line carrying more than 220 volts than a distance equal to the facility's height above the roof or other permanent structure to which it is attached. The proposed 150±-foot concealment pole would be approximately 190 feet northwest of the nearest existing overhead utility lines along the Subject Property frontage on Main Road.Thus, the Proposed Facility complies with this Standard. 5) Co-location. Wireless communication facilities shall be designed to provide for co- location by multiple providers or designed so that they can be retrofitted to accommodate multiple providers, wherever possible. 19 Zoning,Land Use and Environmental Analysis Planning,Zoning and Vi! npact Analysis The proposed concealment pole has been designed to accommodate the antennas of multiple wireless service providers, including those of Verizon Wireless and Dish Wireless, and additional future wireless service providers, in compliance with this standard.The Southold Fire Department would also co-locate its antennas atop the concealment pole. 6) Scenic landscapes and vistas.All antenna support structures which are not concealed :E :E]Dinside of buildings or screened by existing trees or buildings must be surrounded by a planted buffer of dense tree growth.An antenna support structure that is located within a scenic vista or scenic landscape or within 300 feet of a scenic road, as designated by the Town, shall not be taller than 10 feet above the height of trees within a radius of 300 feet Zoniof the proposed location, or 35 feet maximum in the absence of trees. proposed concealment pole would be.situated 174± feet(i.e.,within 300 feet) of Main Road, a Town-designated Scenic Byway, and would reach a height taller than 10 feet above the height of surrounding trees within 300 feet of the concealment pole, a waiver from this standard is required. It is noted that the Subject Property is developed with a large boat storage warehouse structure and paved outdoor boat storage areas that are an established part of the visual landscape along Main Road, along with utility poles and overhead wires along both sides of the street.The existing boat storage warehouse would largely screen views of the equipment compound from views along Main Road.The proposed concealment pole has been designed to conceal the antennas of wireless service carriers within, and will be painted a neutral color to mitigate potential visual impacts to the extent practicable.Additionally, as discussed under standard 4 280-70N(4) above, evergreen trees would be planted around the northern and western perimeters and at the southeast corner of the proposed equipment compound. It is further noted, as analyzed in Section 4, below,the proposed concealment pole would have relatively limited visibility in the surrounding area due to area topography and the presence of intervening vegetation and structures on the visual horizon. 7) Color.Antenna support structures in the form of monopoles or other towers shall either be blue/gray in color or be colored appropriate to the context of the structure's location so that the tower is as unobtrusive as possible, unless otherwise required by the Federal Aviation Administration (FAA). If a wireless communication facility is installed on a structure other than a tower, the antenna and supporting electrical and mechanical equipment must be of a neutral color that is identical to or closely compatible with the colors of the supporting structure so as to make the antenna and related equipment as visually unobtrusive as possible. The proposed concealment pole would be blue/gray in color, consistent with this standard. 8) Wireless facilities sited within new structures meant to mimic some other structure or natural feature must be designed at a scale compatible with the community, be unobtrusive, and be characteristic of the area. The Proposed Facility has not been designed to mimic another structure (e.g.,tree, flagpole, etc.).. However, in an effort to make the proposed Facility as unobtrusive as possible, the monopole would be painted a neutral blue/gray color and would conceal the wireless service antennas within. 9) Antenna support structures in or adjacent to residential zones. Where the site proposed for an antenna support structure is located within a residential zone or has one or more property lines abutting or on the opposite side of a street from a residential zone or use 20 Zoning,Land Use and Environmental Analysis Planning,Zc and Visual Impact Analysis permitted in a residential zone, no antenna support structures may be constructed unless adequately screened from view of those residential zones by existing buildings or large trees, including evergreens. The structure may protrude no more than 10 feet above screening buildings and/or trees. In the absence of an adequate arrangement of existing large trees or buildings to provide effective screening, the height of the proposed structure may be no more than 35 feet, and the base equipment must be buried in an underground �`�`I' '�TVED vault. Two rows of evergreen trees must be planted encircling the structure, one row at a distance from the structure of 50%of the height of the structure, and the other at 90% of AUG 0 9 2023 the height of the structure. Transplanted trees shall have a minimum caliper of three inches, spaced 30 feet on center. The trees must have an expected height at maturity of at Zoning Board of Appeals least 10 feet less than the height of the structure to be screened. Smaller evergreen shrubs must be used to fill gaps in between for screening during the time the trees are filling in and maturing. The Planning Board may vary the arrangement of the trees and shrubs to accommodate specific site conditions, and accomplish the goal of screening the facility from view of residential properties.A written guarantee from the wireless facility's owner shall be required to ensure that the plantings survive and are maintained throughout the existence of the installation. The Subject Property abuts the R-80 Residential District to the north. Given the existing boat storage warehouse and outdoor boat storage areas on the Subject Property, it would not be practical to plant screening vegetation to the extent required by this standard and a waiver is required from the Planning Board pursuant to § 280-76.2(E) of the Town Code. However, as shown on the Compound Plan (Sheets Z-08 and A-1 C in Appendix B),the Proposed Facility would provide landscaped screening at the base of the;equipment compound,to the extent practicable. Specifically, evergreen trees, a minimum of six-feet-tall,would be planted in a staggered pattern along the northern and western perimeter of the equipment compound, as well as at the southeast corner of the equipment compound.While these trees would provide vegetative screening, it should be noted that the position of the equipment compound at the rear of the Subject Property would also serve to limit its visibility from surrounding areas.The equipment compound would be situated behind a large boat storage warehouse, blocking views of the compound from Main Road.The residentially zoned area immediately north of the Subject Property, which already has views to the outdoor boat storage area and warehouse on the Subject Property, contains LIRR tracks and wooded open space, such that there would only be brief, infrequent views of the compound from the north by LIRR passengers;there are no adjacent properties with residential use. 10) Commercial and industrial.siting.Antenna support structures to be sited on developed commercial or industrial properties shall be located to the rear of other principal buildings and shall not.encroach on planting buffers,parking areas or otherwise impair the operation of previously approved systems such as stormwater drainage basins. Existing buildings and structures should be used in the siting of freestanding towers to contribute to the visual screening of the antenna support structure. The Proposed Facility would be situated within the Town's MII District, in an area currently developed with and generally surrounded by commercial marine uses.The Proposed Facility would be installed at the rear of the boat storage warehouse on the Subject Property, in the vicinity of the adjacent LIRR right-of-way, and it would not encroach upon existing landscaped areas or parking areas, nor would it impair any on-site operations. Moreover,the proposed concealment pole would be located approximately 174 feet from Main Road and would be 21 Zoning,Land Use and Environmental Analysis Planning,Zoning and Vi: npact Analysis screened in views from Main Road by the boat storage warehouse.Thus,the'Proposed Facility is consistent with this standard. §280-73-Special Exception Approval Standards. In addition to the standards in Article XXV of this chapter, no special exception Fapproval.shall be granted unless the Planning Board specifically finds and determines the {SEC IVED followin : AUG 0 9 205 1) Construction of the proposed facility or modification of the existing facility is a public 'l `g-j� necessity, in that it is required to meet current or expected demands of the I Zoning Board of Appeals telecommunications provider and to render adequate service to the public. Pursuant to RF reports from Verizon'Wireless, Dish Wireless and the Southold Fire Department (Appendix E), construction of the Proposed Facility and subsequent operation thereof is necessary to remedy an existing service deficiency gap for these carriers and emergency response provider,thereby providing the requisite reliable coverage in the surrounding area. 2) The applicant has made substantial effort to co-locate with existing wireless facilities or, failing that, has made substantial effort to locate on municipally owned land or structures, or within or on existing buildings or structures. As detailed in the Alternative Sites Affidavit (Appendix Q there are no appropriate structures (private or municipal)within the existing service deficiency gap area upon which to co-locate the Proposed Facility, nor are there available public lands within this area upon which a wireless communications facility can be constructed. In an effort to make the Proposed Facility as unobtrusive as possible, a concealment pole would be used to contain the antennas of the wireless service carriers, and the equipment compound would be positioned behind vegetative and structural screening.As such,the Subject Property is the most appropriate location, given the lack of suitable siting opportunities in the surrounding area. 3) There are compelling reasons which make it more feasible to construct the-proposed facilities ratheithan alternatives. As previously indicated,there are no appropriate existing structures within the wireless service deficiency area that would allow co-location as a feasible alternative to the Proposed Facility, and the predominance of residential zoning and development and protected open space in this area of the Town further limits alternate siting opportunities. Given the Subject Property's location in the MII District and development with a large commercial maritime facility adjacent to the LIRR tracks,the Proposed Facility has been sited appropriately as it offers the only feasible alternative for Verizon Wireless and Dish Wireless,which also allows for co-location of the Southold Fire Department antennas and other future wireless service carriers. C. Matters to be considered. In addition to the matters to be considered in Article XXV of this chapter, the Planning Board shall give consideration to the following in issuing a special exception approval for wireless communication facilities: 1) The proposed antenna support structure must be demonstrated to be the lowest height above the ground feasible to achieve the service needs of the carrier(s). The rationale behind the explanation by the applicant must be corroborated by an independent consultant hired by the Town. 22 Zoning,Land Use and Environmental Analysis Planning,Zc and Visual Impact Analysis As discussed above, the RF reports provided by the Co-Applicants (Appendix E) indicate that construction of the proposed concealment pole—designed to accommodate the co-location of Verizon Wireless, Dish Wireless, multiple future wireless service carriers and the Southold Fire District whip antennas, up to a maximum height of 150± feet agl for the concealed wireless service carriers and up to a maximum height of 164-feet-10± inches for the external Southold Fire District whip antennas-is,necessary in order to adequately address wireless service needs in - the surrounding area and emergency response needs. RECFtVM 2) The wireless communication facility has been situated to minimize its proximity and AUf-: 0 9 2023 visibility to residential structures, residential district boundaries and landmarks 3� designated by Town, federal or state agencies. Zoning, Board o~, Aopeals The Proposed Facility would not be situated proximate to any landmarks,whether Town,federal or state-designated. ,The Proposed Facility would be situated within a mixed-use area,which includes residential zoning to the north,west and southwest of the Subject Property. However, as indicated above, the Subject Property is separated from these residential areas by the LIRR right-of-way and open space to the north and Main Road and open space to the south. Moreover, as depicted in the photographic simulations presented in Appendix A and analy'ed in Section 4 below,the proposed concealment pole would be as visually inconspicuous as practicable,with limited visibility throughout the surrounding area.Where visible,the design features of the proposed concealment pole, including a neutral coloration and the concealment of wireless service antennas within the pole,would serve to mitigate visual impacts. Overall, given the lack of feasible alternative siting opportunities within the service deficiency area,the Proposed Facility location and design represent the least obtrusive option available. 3) The wireless communication facility is designed and situated to be compatible with the nature of uses on adjacent and nearby property. The Proposed Facility is designed to be compatible with the nature of uses on adjacent and nearby properties,which.consist of a mix of commercial maritime uses,the LIRR right-of-way, open space,-agricultural and residential properties.The use of a concealment pole that would hide the antennas of multiple wireless service carriers would obviate the need for multiple antenna support structures through co-location, along with co-location of Southold Fire Department.antennas.The painting of the concealment pole a neutral color would help it blend with the sky to the extent practicable, and the screening of the ground-based.equipment compound would limit views from Main Road.Therefore,the Proposed Facility is sited and designed to be as compatible as practicable with the surrounding area, in keeping with this standard. 4) The wireless communication facility has been designed to use the surrounding topography to minimize its visual impacts. While there are not significant topographic variations in the area surrounding the Subject Property,the results of the visual impact analysis presented in Section 4 below, do indicate that views of the proposed concealment pole would be limited in the surrounding area due to intervening vegetative cover and structures. In areas where the proposed concealment pole would be visible,the previously discussed design aspects (i.e., neutral coloration, concealment of antennas)would help to minimize visual,impacts. 23 Zoning,Land Use and Environmental Analysis Planning,Zoning and V mpact Analysis 5) The wireless communication facility has been designed to use the surrounding tree, building or foliage coverage to minimize its visual impacts. The Subject Property does not contain tree coverage, as it has previously been developed as a boat storage and maintenance facility. However, as discussed in more detail in Section 4 below, intervening"vegetation and other obstructions would limit visibility of the proposed concealment pole in the surrounding area. Furthermore,the proposed concealment pole and fenced equipment compound would be installed behind an existing boat storage warehouse and evergreen screening would be planted to further conceal the equipment compound and base of RECEIVED �he pole, helping to minimize its visual impacts. AUG 0 9'2023 6) The wireless communication facility maximizes design characteristics to reduce or eliminate visual impacts and obtrusiveness. Zoning Board of Appeals As discussed above,the Proposed Facility would be installed between an existing building and the LIRR tracks, additional screening vegetation would be installed,the proposed concealment pole would conceal the antennas of wireless service carriers within, and would be painted a neutral color.These design characteristics help to mitigate potential visual impacts and obtrusiveness. 7) Other adequate conditions have been placed on the wireless communication facility which will minimize any adverse impacts of the facility on adjoining properties. Given that the Co-Applicants have designed the Proposed Facility such that potential visual impacts would be minimized to the extent practicable, and that operations associated with the Proposed Facility would be entirely contained on the Subject Property,the Proposed Facility would not have significant adverse impacts on adjacent properties. §280776.2— Waivers of Criteria In approving a site plan or special exception, the Planning Board may waive or modify the following criteria if it finds that the goals and stated purposes of this article are better served by doing so, and that there is no detriment to the public health,safety and welfare. A. Section 280-70.1(2), Maximum height.80 feet. In commercial zones, where co-location will achieve the result of fewer antenna support structures, the Planning Board may modify the eighty-foot height restriction with the condition that the antenna support structure be constructed so that antennas can be installed at any height on the structure, and that the overall height of the structure can be reduced if antennas are moved to lower heights. No antenna support structure shall remain at a height that is taller than that required by installed and operational antennas. The applicant must show that co-location of other carriers is likely by demonstrating that coverage or capacity gaps of other carriers are located in the same area as the proposed structure. The Proposed Facility would require a waiver from the Planning Board to permit the installation of a 150±-foot-tall concealment pole (with Southold Fire Department antennas reaching a top height of 164-feet-10± inches agl)where a maximum height of 80 feet is allowed.Although the Proposed Facility would exceed the height standard,the requested height is required in order to address the wireless service deficiency in the area, as demonstrated in the RF reports included in Appendix E.Additionally, as discussed in the letter prepared by IWT for the Southold Fire District (Appendix E) dated October 24, 2022, "the additional tower is required to provide a public safety quality of communications service in areas frequented by the Fire District... 150 [feet] is required 24 Zoning,Land Use and Environmental Analysis Planning,Zc and Visual Impact Analysis to provide coverage at levels acceptable for Public Safety communications systems and ensure the ability for the fire fighter to communicate during critical calls" (IWT, paragraph 1). Moreover, in addition to the Southold Fire Department,Verizon Wireless and Dish Wireless,the Proposed Facility would be able to accommodate the co-location of additional wireless communication providers,thereby obviating the potential need for an additional structure(s) in the future. Fp F-CENED B. Section 280-70.1(3), Minimum distance of all wireless equipment to adjacent residential property lines or streets shall be no less than 500 feet. This setback requirement may be AUG ® 9 2023 modified upon a showing by the applicant that the actual distance of the antenna support ��j� structure to the.residential structure is minimized to the greatest extent possible. Boas of A.ppeafs Zoning The Proposed Facility would require a waiver from the Planning Board,to allow the siting of the Proposed Facility within 500 feet of an adjacent residential property line or street.The Proposed Facility would be situated a minimum of eight± feet from the northern property line,which coincides with a transition to the R-80 residential zoning district. However, beyond this property line is a transportation use (i.e.,the LIRR corridor),followed by open space to the north, and there are no residential structures within,500 feet of the Proposed Facility. Despite the placement of the Proposed Facility within 500 feet of the nearest residential property line,the site has been chosen to be the least obtrusive feasible, in the rear portion of the Subject Property, near the LIRR right-of-way and surrounded by commercial marine uses and open space. C Section 280-72.A(6), Scenic landscapes and vistas. The requirement of planting of surrounding tree coverage and foliage to account for existing vegetation and land contours may be modified by the Planning Board but only in cases where it can be shown that the existing vegetation achieves the purpose of concealing the structure. As the proposed concealment pole would be situated 174± feet (i.e.,within 300 feet) of Main Road, a Town-designated Scenic Byway, and would reach a height taller than 10 feet above the height of surrounding trees within 300 feet of the concealment pole(i.e.,the limits set forth at§ 280-72.A[6)), a waiver from this standard is required. It is noted that the Subject Property is developed with a large boat storage warehouse structure and paved outdoor boat storage areas that are an established part of the visual landscape along Main Road, along with utility poles and overhead wires along both sides of the street.The existing boat storage warehouse would largely screen views of the equipment compound from views along Main Road.The proposed concealment pole has been designed to conceal the antennas of wireless service carriers within, and will be painted a neutral color in an effort to mitigate potential visual impacts to the extent practicable.Additionally, as discussed under standard § 280-70N(4) above, evergreen trees would be planted around the northern and western perimeters and at the southeast corner of the proposed equipment compound. It is further noted, as analyzed in Section 4, below,the .proposed concealment pole would have relatively limited visibility in the surrounding area due to area topography and the presence of intervening vegetation and structures on the visual horizon. E. Section 280-72A(9),Antenna support structures in or adjacent to residential zones. If the structure is located on a property that is adjacent to a residential zone, the Planning Board may modify the requirement of planting of surrounding tree coverage and foliage in cases where it can be shown that existing vegetation and land contours achieve the purpose of concealing the structure from nearby residences. The Subject Property abuts the R-80 Residential District to the north. Given the existing boat storage warehouse and outdoor boat storage areas on the Subject Property, it would not be 25 Zoning,Land Use and Environmental Analysis Planning,Zoning and V mpact Analysis practical to plant screening vegetation to the extent required by this standard and a waiver is required from the Planning Board. However, as shown on the Compound Plan (Sheets Z-08 and A-1C in Appendix B),the Proposed Facility would provide landscaped screening at the base of the equipment compound, to the extent practicable.Specifically, evergreen trees, a minimum of six-feet-tall,would be planted in a staggered pattern along the northern and western perimeter of the equipment compound, as well as at the southeast corner of the equipment compound. While theseltrees would provide vegetative screening, it should be noted that the position of the equipment compound at the rear of the Subject Property would also serve to limit its visibility from surrounding areas.The equipment compound would be situated behind a large boat storage warehouse, blocking views of the compound from.Main Road.The residentially zoned area immediately north"of the Subject Property,which already has views to the outdoor boat storage area and warehouse on the Subject Property, contains LIRR tracks and wooded open space, such that there would only be brief, infrequent views of the compound from the north by LIRR passengers;there are no adjacent properties with residential use. §280-76.3-Relief With the exception of relief from the denial of an application for a special exception approval pursuant to§280-73, any applicant desiring any other relief or exemption from the requirements of this article may seek a variance from the Zoning Board of Appeals in accordance with Article XXVI of this chapter. As discussed above,the Proposed Facility requires variances from the ZBA from the minimum lot size and rear yard requirements. Detailed discussions of the requested variances from the minimum lot size and rear yard requirements are provided above. RECEIVED AUG 0 9 2023 Zoning g Board of Appeals 26 Zoning,Land Use and Environmental Analysis Planning,Zc and Visual Impact Analysis Since the Proposed Facility would be unoccupied,there would be minimal impact on the environmental conditions in the area.The Proposed Facility would not generate sewage or solid waste and would not need to be supplied with potable water. A nominal,temporary increase in traffic would be expected during construction of the Proposed Facility.Traffic associated with the operation of the Proposed Facility would be de minimis, as the site would be unmanned and remotely monitored.There would be approximately one trip per month per carrier/Southold Fire Department by a technician in a passenger-type vehicle to inspect and maintain the equipment.Additionally,the equipment installed on the site would use minimal electricity. Minimal ground disturbance would be necessary(i.e., 0.08± acre)to accommodate the proposed equipment compound, concealment pole, landscaping,fencing, and trenching of utility lines.The areas to be disturbed are not natural areas and are currently occupied with paved areas used for outdoor boat storage.As such, no natural areas would be disturbed. Furthermore, as indicated on the project plans submitted with the application (Appendix B)the Proposed Facility would involve the planting of evergreen trees along the northern and western perimeter of the equipment compound, creating new landscaped areas and reducing impervious surface area at the site by 0.04± acre. According to the NYSDEC EAF Mapper and New York Nature Explorer, records for the federal/NYS listed species Piping Plover(NYS and federal - Endangered), Least Tern (NYS - Threatened), Common Tern (NYS -Threatened) and Black Skimmer(NYS - Special Concern) exist for the Subject Property vicinity. However,the Subject Property consists of developed upland areas and does not support the requisite aquatic and shoreline habitats for these shorebird species.As such, potential habitat for these species would not be impacted by the Proposed Facility. The Project Area is within the 100-foot jurisdictional adjacent area of NYSDEC and Town of Southold regulated freshwater wetlands. However, as noted above,the Subject Property and Proposed Facility area consist of developed upland areas,with no natural areas present. Consultation is underway to secure wetlands permits from the NYSDEC and the Town.As provided by the project engineer,Azimuth Engineering, during construction, silt fence, straw bales, and other erosion and silt controls will be installed and maintained, as necessary, to prevent adverse impacts on wetlands The Subject Property is within an area identified as archaeologically sensitive by the New York State Office of Parks, Recreation and Historic Preservation (OPRHP). By correspondence dated November 16, 2017, OPRHP concurred that there are No Historic Properties in the Area of Potential Effects (APE)for Direct Effects, and the Proposed Facility would have No Adverse Effect on Historic Properties in the APE for Visual Effects (Appendix H). RECEIVED AUG 0 9 2023 I "7S3 ) :I Zontrig Board a. 27 Zoning,Land Use and Environmental Analysis Planning,Zoning and Vi mpact Analysis RECEIVED 4AUG 0 9 20023 Zonin B793 / 9 Board of Appeals Visual Impact Analysis Multiple analyses were undertaken to assess the.potential visual impacts of the Proposed Facility, including a Viewshed Analysis, a One-Mile Visibility Study, and an analysis of photographic simulations.Together,these analyses comprehensively represent the expected visibility of the Proposed Facility, and evaluate the potential for the Proposed Facility to have an adverse visual impact upon the surrounding community.As detailed below, these analyses confirm that the Proposed Facility will not result in a significant adverse visual impact. . 4.1 Viewshed Analysis To perform a viewshed analysis of the Proposed Facility,VHB used published LiDAR(Light Detection and Ranging) imaging data available from the United States Geological Survey2 to predict the visibility of the Proposed Facility from the surrounding area.Specifically, a model was prepared to identify those areas within an approximate one-mile radius that would have views of the Proposed Facility given the topography of the area and the presence of vegetation/foliage. The model was prepared to estimate visibility of the top of.the proposed Southold Fire Department antennas atop the concealment pole for a 1.66-meter(5.5-foot)-tall individual standing at ground level. Based on the results of the model, a Viewshed Analysis map (Figure 4) identifying those areas having views of the proposed concealment pole was then prepared. As depicted in Figure 4, which illustrates the results of the viewshed analysis,the proposed concealment pole would be expected to be visible in the immediate area of the Subject Property . along Main Road (NYS Route 25),with visibility becoming more intermittent along Main Road as one travels east or west away from the Subject Property.The LIRR right-of-way,which adjoins the Subject Property to the north, is also expected to have intermittent views of the proposed concealment pole.There is also expected to be intermittently visible elsewhere within the one- mile radius in all directions, but primarily to the north, east and south of the Subject Property, mostly in cleared areas devoid of extensive tree cover, on the waters of Hashamomuck Pond and Shelter Island Sound, and at the shoreline edges of those waters.The Viewshed Analysis model also shows that the proposed concealment pole would not be expected to be visible to persons standing on the ground in the majority of residential areas surrounding the Subject Property. Z United States Geological Survey."USGS Long Island New York Sandy Lidar Classified LAS 1.2."November 14,2014(Accessed May 2023). Available at https://(iisdata.ny.gov/elevation/LIDAR/USGS Long Island2014/USGS Long Island Sandy Lidar Classified LAS.xml 28 Visual Impact Analysis Figure 4: Viewshed Model vhb Proposed Wireless Communications Facility - Albertson Marine 61405 Main Road, hamlet of Southold, Town of Southold, Suffolk Count A� Qoaa p�Oes Albertson Lane °da B o�ndi�ev+P�enUe S d'a e oaa c' �`aa\eQ- C.�e o .. Sage gou/evard Q _ w� gee o° - v A � L 00. i e 0 N N N d c D ,9 � N d9 . G °ob, G � ! S°6 roe„ �A d�P d� NA _Ld �Od drh ! y d� c� i N 0 0.5 Miles Q Proposed Facility Location Q 1-Mile Radius Areas predicted to have views of the proposed concealment pole RECEIVED UG U 9 2023". ZOnin9 80�o , Source 0/thoimage by Iveannap(October 2022), USGS Long Island LOAR Collection(2014), 1'HB(20 3). q'ppeals 29 Planning,Zoning and V mpact Analysis Overall,the Viewshed Analysis demonstrates that visibility of the proposed concealment pole would be varied.The extensive tree cover in the majority of the area surrounding the Subject Property would screen views of the proposed concealment pole, especially in residential areas and wooded open space areas.Views of the proposed concealment pole are expected to be limited to those areas described above in the immediate vicinity of the Subject Property and on portions of cleared land and surface waters.As will be discussed below,the results of this viewshed analysis are consistent with the one-mile visibility study and photographic simulations. 4.2 One-Mile VQsi.bs6ety Study To confirm the results of the viewshed analysis, and to supplement that data with respect to visibility of the proposed concealment pole from surrounding areas, a one-mile visibility study was performed by VHB on April 11, 2023.A crane with an attached orange and white flag (to provide a distinct visual reference)was positioned at the proposed concealment pole location and raised to the top height of the proposed Southold Fire Department antennas (i.e., 164-feet- 10±-inches agl).All publicly accessible roadways within a one-mile radius of the proposed concealment pole location (the"Study Area")were traveled while the crane was in place.As requested by the Town,the area of Goose Creek Beach, outside of the one-mile radius,was also visited to assess visibility. Observations were continually recorded as to whether the flag was visible (largely unobstructed), partially visible (obstructed), or not visible (completely obstructed) while traveling along each,public roadway.The data collected during the one-mile visibility study was overlaid ori a map of the Study Area to 'illustrate those publicly accessible roadways from which the proposed,concealment pole would be visible, partially visible, or not visible. Photographs were taken at areas where the crane was visible and partially visible.The photograph locations are labeled on Figure 5 and the photographs are presented in Appendix I. In photographs where,the flag atop the crane is not easily seen, an arrow has been added to aid the viewer. It should be noted that, as demonstrated by the photographs in Appendix I,the one- mile visibility study was conducted during "leaf-off" conditions, before most deciduous trees in the surrounding area have developed foliage for the year, such that these results are conservative and represent a worst-case scenario. During the several months each year when foliage is present(i.e., approximately May through November), views of the proposed concealment pole would be partially or fully screened in areas where intervening deciduous vegetation is present. As depicted in Figure 5, along publicly accessible roadways,full visibility of the proposed concealment pole would be limited to portions of Main Road, Old Main Road, Bayview Avenue, Pond Avenue, Laurel Avenue, Budds Pond Road,Willow Point Road, and Goose Creek Beach,with intermittent partial visibility from a few other residential streets.These residential streets include Pond Avenue, Park Avenue, Long Creek Drive, Laurel Avenue, Mill Creek Drive, Bayview Avenue, Bay Home Road,Willow Point Road, Dolphin Drive, and Albacore Drive.Areas with partial visibility are largely due to obstruction by the presence of trees or buildings. It is also noted that, in areas with both partial and full visibility,the established visual character often includes existing utility poles and overhead utility lines. REC;EVEDI AUG 92202330 Visual Impact Analysis 7 3Zoning Boaot;; -'Is Figure 5: One-Mile Visibility Study Proposed Wireless Communications Facility - Albertson Marine 61405 Main Road, hamlet of Southold, Town of Southold, Suffolk County FlOad p8 Co��cl q/bPnsOn'(a�e soundview Av/nue ` � �� P PZy� Bay h uPAugust Roa�oda a 17 O Sage 80ul yala Old North Road 1`,e C,� 8 ee� 1 11 A ctQj%4e G 1 .9P o7� A 13 o —Fvg) ye°°ecO o9 �'c 1 6J n 0 " °ad 5 c `°Q y �a Rocky point Avenue L 7 a� moa Z 0 0 °N r /Y 06 d?, 0 110.1 �O Cj�` dry PSti P� C d P� 47 GP 9` P7 GP �O P`Me14ecooad 90 h,N 1L 'Po,, Goose Creek Beach N 0 0.5 Miles 0 1-Mile Radius Roadways with Partial Views of Concealment Pole 0 Proposed Facility Location Private Roadways Roadways with Views of Concealment Pole FZ0nj:- ECEIVED G 0 9 2023 Source. VH8(2023),Suffolk County GIS �r6 Planning,Zoning and V mpact Analysis The results of the one-mile visibility study are generally consistent with the findings of the Viewshed Analysis,which similarly predicted varied visibility on Main Road, Pond Avenue, and Bayview Avenue.As such,the one-mile visibility study further demonstrates that visibility of the proposed concealment pole would be limited,whereas the majority of the surrounding area would not have views of same. 4.3 Photographic Simulations To supplement data collected and analyzed as part of the viewshed analysis and one-mile visibility study, photographic simulations were prepared to provide a visual representation of the Proposed Facility from several View Points throughout the surrounding community.These simulations provide reference as to where and what degree the Proposed Facility will be seen in the surrounding area.They are also useful in characterizing and portraying the existing visual obstructions to the horizon present in the environmental setting of the Proposed Facility. 4.3.1 Methodology Photographs were obtained from nine publicly accessible View Points, identified in consultation with the Town of Southold, during a field visit by VHB on April 11, 2023 (see Figure 6).All photographs were taken facing the location of the Proposed Facility using a high-quality Canon Rebel digital camera with a 50mm equivalent lens,which has a viewing angle that most closely matches that of the human eye.The photographic simulations were computer generated through the use of design software. Specifically, Infraworks was used to compute the existing ground conditions, utilizing one-meter LiDAR data from USGS, captured in 2014; and one foot/pixel resolution through Nearmap aerial images, captured in March 2023,were overlaid on the LiDAR terrain and used to identify existing features, such as buildings, light posts, and parking lot lines.The proposed structure plans were received from the project engineer, modeled in Sketchup, and incorporated into the scene at the correct elevation.The existing conditions model was exported to Sketchup to begin the photo matching process, in which nine photograph locations were identified to serve as the photosimulation backgrounds.,The team reviewed the photographs for artificial features that exist in each and in the existing conditions model.Vertical support lines were placed at each of the artificial features and the base of one of those features then became the origin point of the photograph match. Scale was set by adjusting the model to match two planar objects in the scene and then the X and Y vanishing points were then adjusted until all vertical supports in the ground model matched the corresponding artificial objects in the background photograph.All Sketchup layers were turned off, and the background images were exported.Then, the proposed structure layer was turned on with the background image and exported. Finally,the proposed model was rendered in V-Ray rendering software and exported as a transparent PNG image file. 7023 ED 7 Ff Appeals 32 Visual Impact Analysis • •.. Mmill - IRS LVA F"m Me ImMem A. Y AL t _ tI f T f \ t• ��•�� � - .�{�'` 1.t�;�`,;Q t;� -� ~ RECEIVS • ; ��, ':'�'. �_,, ._��y ate. 1 AUG 2023 zoni I . - r rr- I . r r I� • I g BoardOf ,._ Planning,Zoning and V Impact Analysis All layers were combined in photoshop, reviewed, and then the proposed structure and background image was removed, leaving only the existing conditions layer with the proposed model.The resulting image was then masked, allowing any foreground elements in the photograph to sit in front of the proposed model. Final images of the existing and proposed were then exported, providing a realistic photosimulation of the Proposed Facility. On the View Point photographs where the Proposed Facility would not be visible, or where the facility is visible but may be difficult to identify in the simulation due to its camouflage, etc., an arrow has been added to indicate the position of the top of the Proposed Facility behind the intervening bstructions. RECEIVED I total, nine View Points throughout the surrounding community,which were selected in AUG 0 9 2023 c nsultation with the Town of Southold,were included in the analysis of potential visual impacts. 7Vq O these nine View Points, photographic simulations were prepared for four View Points where Zoning Board of Appealt Proposed Facility would be visible (see Appendix A).The Proposed Facility would not be visible from the remaining five View Point locations, and therefore, no photographic simulations were prepared for those View Points. Each of the View Points are analyzed below. View Point 1-from Main Road,5,328± feet southwest of the Proposed Facility The View Point 1 existing conditions photograph depicts two-story commercial buildings along Main Road,with utility poles and overhead wires running along both sides of the street, and evergreen and deciduous trees along the road and between the structures. Due to intervening topography, mature vegetation, buildings and other obstructions to the horizon,the Proposed Facility would not be visible from this View Point, and no adverse visual impacts would result. View Point 2-from Main Road,2,626± feet southwest of the Proposed Facility The View Point 2 existing conditions photograph depicts mature vegetation along Main Road, with utility poles and overhead wires running along both sides of the street. Street signs,fencing and a two-story structure are also visible from this View Point. Due to intervening topography and mature vegetation, the Proposed Facility would not be visible from this View Point, and no adverse visual impacts would result. View Point 3-from Park Avenue and Pond Avenue, 1,499±feet northwest of the Proposed Facility The View Point 3 existing conditions photograph depicts the residential road of Pond Avenue at the intersection of Park Avenue, including a mix of mature evergreen and deciduous trees on an open space parcel at the edge of the residential area. Due to intervening topography and mature vegetation,the Proposed Facility would not be visible from this View Point, and no adverse visual impacts would result. View Point 4-from the NYSDEC Boat Launch on Old Main Road, 1,491± feet east of the Proposed Facility The View Point 4 existing conditions photograph depicts the area around the NYSDEC Boat Launch, including a paved parking lot, landscaped areas, one- and two-story buildings, utility poles and overhead wires,trees, and boats stored on land.The photographic simulation indicates that the Proposed Facility would be visible from this location, although the bottom portion of the concealment pole would be obscured by buildings, utility lines, and trees.The Proposed Facility includes mitigating design elements, including the concealment of wireless service carrier antennas within the pole, and a neutral paint color that would blend with the sky to the extent practicable. Furthermore, it is noted that utility poles and overhead wires are visible on the 34 Visual Impact Analysis Planning,Zo 3nd Visual Impact Analysis horizon, such that obstructions to the horizon are an established part of the visual landscape at this View Point. Based on the design of the proposed concealment pole and the presence of intervening buildings,trees and utility lines,the Proposed Facility would not result in significant adverse visual impacts from this View Point. 'ECE� 'E) View Point 5-from Main Road,2,600± feet northeast of the Proposed Facility ASG 9 223 The View Point 5 existing conditions photograph depicts surface waters and shoreline south of $31 eaiS ain Road,with landscaped and natural areas, as well as boats, commercial marina structures, Zoning Board of APP verhead utility lines and mature trees on the horizon.The photographic simulation indicates that the Proposed Facility would be visible from this location, although the bottom portion of the concealment pole would be obscured by buildings, utility lines, and trees.The Proposed Facility . includes mitigating design elements, including the concealment of wireless service carrier antennas within the pole, and a neutral paint color that would blend with the sky to the extent practicable. Based on the design of the proposed concealment pole,the Proposed Facility would not result in significant adverse visual impacts from this View Point. View Point 6-from Main Road,5,152± feet northeast of the Proposed Facility The View Point 6 existing conditions photograph depicts a portion of Main Road bordered by vegetation including mature evergreen and deciduous trees. Due to intervening topography and mature vegetation,the Proposed Facility would not be visible from this View Point, and no adverse visual impacts would result. View Point 7-from Bayview Avenue,3,353± feet northeast of the Proposed Facility The View Point 7 existing conditions photograph depicts Hashamomuck Pond,with wooded areas of the Paul Stoutenburgh Preserve beyond the Pond.The photographic simulation indicates that the top of the proposed concealment pole would be visible from this location, extending slightly above the tree line,while the middle and lower portions would be obscured by dense, mature vegetation within the Preserve. Given that only a small portion of the Proposed Facility would be visible, and that the concealment pole would be painted a neutral color to blend with the sky to the extent practicable,the Proposed Facility would not result in significant adverse visual impacts from this View Point. View Point 8-from Town Beach,5,245± feet north of the Proposed Facility The View Point 8 existing conditions photograph depicts the parking lot of the Southold Town Beach, North Road, residential structures across North Road,with utility poles and overhead wireless running along the road. Hashamomuck Pond is visible behold the residential structures, and the horizon consists of a dense wooded area. Due to intervening topography, mature vegetation and.the presence of existing development,the Proposed Facility would not be visible from this View Point, and no adverse visual impacts would result. View Point 9-from Goose Creek Beach, 9,136± feet south of the Proposed Facility The View Point 9 existing conditions photograph depicts Goose Creek Beach, Shelter Island Sound, and the land across Shelter Island Sound, including residential buildings and marina facilities,with mature trees on the horizon.The photographic simulation indicates that the Proposed Facility would be from this View Point, although the lower portion of the concealment pole would be obscured by the trees on the horizon.The Proposed Facility includes mitigating 35 Visual Impact Analysis Planning,Zoning and V mpact Analysis design elements, including the concealment of wireless service carrier antennas within the pole, and a neutral paint color that would blend with the sky to the extent practicable.This simulation highlights the benefits of the concealment pole design and neutral coloration, as it is barely discernible from the sky at this substantial distance (approximately one-and-three-quarter miles away). Based on the design of the proposed concealment pole and the presence of intervening trees.that obscure the lower portion of the concealment pole,the Proposed Facility would not result in significant adverse visual impacts from this View Point. Overall,the viewshed analysis, one-mile visibility study and photographic simulations each confirm that visibility of the Proposed Facility in the surrounding area would be limited. Of the nine View Points selected by the Town for analysis, only four would be altered by the addition of the Proposed Facility to the landscape.The extensive dense tree cover throughout the surrounding area provides screening to limit the extent of the area where the Proposed Facility would be visible, and also obscures the Proposed Facility from other View Points where it would be partially visible.While the Proposed Facility would be visible from some areas with less tree cover and intervening structures (i.e., across surface waters and at the nearest portions of Main Road),the photographic simulations demonstrate the mitigating design elements of the . Proposed Facility, including the concealment of wireless service carrier antennas within the pole and the neutral paint color that allows the Proposed Facility to blend with the sky to the extent practicable. Based on these analyses, no significant adverse visual impacts would result from the construction of the Proposed Facility. Zoning RECEIVE® AUG 0 9 2023 od or appeals 36 Visual Impact Analysis Planning,Zoning and V mpact Analysis RECEIVED AUG 09 2023 Zoning B0 79— of gpPeals 5 Findings and Conclusions Based upon an inspection of the Subject Property location and surrounding area, review of the Town Code and Zoning Map, evaluation of characteristics of the Proposed Facility, and examination of potential visual impacts using a viewshed model,field reconnaissance and photographic simulations,the following findings and conclusions can be made: 1. From a planning perspective, given the siting of the Proposed Facility,within a commercial property that currently contains a boat storage warehouse and outdoor boat storage, adjacent to the LIRR right-of-way,the Co-Applicants have chosen an appropriate and suitable location for the Proposed Facility in order to address existing service deficiencies in the Southold area in a manner that minimizes potential impacts. In addition, there are no existing, feasible higher priority locations,towers or antenna support structures that can accommodate the Proposed Facility in order to address the existing service deficiencies in the area.The Proposed Facility would accommodate the co-location of Verizon Wireless, Dish Wireless, future additional wireless service carriers, and the Southold Fire Department,thereby limiting the need for the installation of multiple similar structures (i.e. monopoles or concealment poles)within Southold, and complying with the Town Code. z. The Proposed Facility would have minimal impacts on the environmental conditions at the Subject Property and surrounding area, as it would be unmanned and situated on a commercially developed site with no natural areas present. No sewage or solid waste would be generated, nor would potable water be required. In addition,the Proposed Facility would neither store nor utilize compounds that pose a significant threat of soil or water contamination.Although the Proposed Facility would be located within an area that is within the regulatory jurisdiction of the NYSDEC and Town for freshwater wetlands (i.e., within 100 feet of freshwater wetlands),the Proposed Facility would not result in disturbance to the freshwater wetland area. Freshwater wetlands permits will be obtained from the NYSDEC and the Town prior to construction,and appropriate erosion and sedimentation controls will be employed during construction to be protective of the wetlands.Additionally, screening vegetation would be planted at the base of the Proposed Facility, resulting in a slight decrease in the amount of impervious surfaces at the Subject Property. Project-generated traffic would be minimal, as the Proposed Facility would be monitored remotely and would require approximately one vehicle trip per carrier per month by a technician in a passenger- type vehicle. No impacts to ecological resources are anticipated as the project area within the 37 Findings and Conclusions Planning,Zor nd Visual Impact Analysis Subject Property is already developed with paved areas used by the boat storage and maintenance operation on the Subject Property and its adjoining parcels to the east and west. 3. The Proposed Facility has been designed to minimize visual impacts.The Proposed Facility would utilize a concealment pole design to enclose the wireless service antennas within the pole, and the equipment compound would be screened by the existing on-site boat storage warehouse, as well as a six-foot-tall chain link fence and evergreen plantings. Only the Southold Fire Department antennas would be mounted on the exterior of the concealment pole. However, other similar structures with exterior mounted emergency service antennas are present along Main Road in the Town.Although the Proposed Facility would be visible from portions of the surrounding area,visual impacts are mitigated to the extent practicable by the concealment of antennas within the pole and the painting of the pole a neutral color to blend with the sky. Furthermore,the co-location of multiple wireless service providers at the Proposed Facility helps prevent the proliferation of multiple, single-carrier facilities in the area experiencing the service deficiency.Thus, all reasonable measures have been taken to minimize the visual impact of the Proposed Facility. 4. To the extent practicable,the Proposed Facility has been sited and designed to be consistent with the Town Code standards for wireless communications facilities.The requested waivers, fall zone relaxation and variances are largely a result of the size and shape of the Subject Property, the design requirements to address the service deficiencies, and the lack of available alternative parcels. Overall,the Proposed Facility has been sited and designed in a manner that would serve to minimize potential impacts to the greatest extent possible,while providing much needed wireless service and emergency response communications upgrades to the Southold area.The Co-Applicants have chosen the least obtrusive location and design for the Proposed Facility that will address the existing service deficiencies.Accordingly, it is respectfully requested that the Planning Board grant a special exception permit,waivers and a fall zone relaxation, and the ZBA grant variances,for the Proposed.Facility to enable the Southold Fire Department,Verizon Wireless and Dish Wireless to provide reliable communications in the area of the Subject Property. E V �I fill d a�srd oR�r a s 38 Findings and Conclusions • Appendix RECEIVED AUG 0 92023 Photographic Simulations Zoning Board f ra a 9 p Appeals . s'�i s .•.. R �r"..'�"f..'r + 'alo+�a.:w ' r7 b p ixM 1� ? n . »•. w 1 .Q'l�ry�R�C F �L-i' �� t��.� �'c`yT�^�'✓-r f, �y?7k1�- ,�_ 1.��•Y` �w � VIS iUAL AS�S�ESSiENT • AN,D` PHQTOSTMULATI IAVS, - 7eiFMY �.. yr it Proposed Wireless Communications Facility — Albertson Marine 61405 Main Road -- Southold, Town of Southold, Suffolk County, New York e ' Prepared by: VHB 100 Motor Parkway, Suite 350 Hauppauge, NY 11788 631.787.3400 May 2023 Methodology Photographs were obtained from nine publicly accessible View Points, assigned by the Town of Southold, during a field visit by VHB on April 11, 2023. All photographs were taken facing the location of the proposed Facility using a high-quality Canon Rebel digital camera with a 50mm equivalent lens, which has a viewing angle that most closely matches that of the human eye. The photographic simulations were computer generated through the use of design software. Specifically, Infraworks was used to compute the existing ground conditions, utilizing one-meter Lidar data from USGS; captured in 2014; and one foot/pixel resolution through Nearmap aerial images, captured in March 2023, were overlaid on the Lidar terrain and used to identify existing features, such as buildings; light posts, and parking lot lines. The proposed structure plans was received from the Applicant's engineer, modeled in Sketchup, and incorporated into the scene at the correct elevation. The existing conditions model was exported to Sketchup to begin the photo matching process, in which nine photograph locations were identified to serve as the photosimulation backgrounds. The team reviewed the photographs for artificial features that exist in each and in the existing conditions model. Vertical support lines were placed at each of the artificial features and the base of one of those features then became the origin point of the photograph match. Scale was set by adjusting the model to match two planar objects in the scene and then the X and Y vanishing points were then adjusted until all vertical supports in the ground model matched the corresponding artificial objects in the background photograph. All Sketchup layers were turned off, and the background images were exported. Then, the proposed structure layer was turned on with the background image and exported. Finally, the proposed model was rendered in Way and exported as a transparent PNG. All layers were combined in photoshop, reviewed, and then the proposed structure and background image was removed, leaving only the existing conditions layer with the proposed model. The resulting image was then masked, allowing any foreground elements in the photograph to sit in front of the proposed model. Final images of the existing and proposed were then exported, providing a realistic photosimulation. On the View.Point photographs where the Proposed Facility would not be visible, an arrow has been added to indicate the position of the top of the Proposed Facility behind the intervening obstructions. FN 0 0 D n F0 Icy a vo M avec � R Wo m -0 w W Me.. • •R�+�� to �Gf�7 ; i�i�.. ow— �� ♦`` .rte R•7; i'rf.����• /�'\MI/�. �\�r�'• *, ���� �' �' � ������ '-:,,,� ,,_.�'i:,rte` r •• fit ` �'•a�•, �• "�•�iA"-44 �� mew wk lea rw—�_ i'�. } _ :�:•: �w, fj '� �'► n+'+ �•�� . •�ii.'i'i'.'��•''er; _ ..fir,,,. ' ara ��►. '�►A1r;i. ►� _ `.� cr, d� =.� y �11�- "��a'bv+4Qi�►. li`. I� Q �J� err••Iv.....,,, - _j•..� _��"� _ ••.• . • IFUNTMOrsTi . - Wl.r I r,,jufp ,:+�.••; �►,$,,, �.,?: " ;� �;� !► ',�, 1 :;chi ��;� ,:, r v + yy5 i! .;?w !•�_ � f ` .�! '• ' ��►�ray+ • rr , • _ .����� a .•i • ���h �� � . M- ,a ► a 4T .�' i _ ref �f' :�f 'K ~ t •Ej� i, �_�`.: +.�+ r �► �J gr 4. row Tr.. !` � � '! 1� _ '•' •-mss . ��r•R�`, :r� '-.off•'' , 114 PW VA y �` �'y���"s'(• y I �� hl,w � - f ,,t�• Nina/a ,�r .i► t. 1 •� -. � ,'.(� 1 110.r�Y��,. \\` � ly .. ♦ •� � t . , / V \\\y f� / .g S \ .{�/ Y•t,��y,, �,. * / �r/ �_ y�rvt • n -- L mill sw '' ° PI "` • r�ap�� e��,l x• CL • cu CD .. ik� t "� o���'F�rO t 1 F r t i' f.` w� "Y:��e �}-•.f 7�.•'r �,�;`' •C, � Jt. .1 ' 02 � ��� -.y!! 'ii f�'� M1tt..x.. �r�`�� Y•�M i M•r �f� � 7 � ..� � f•• .ter ��>.��-ac.«:.F '�-'''�'nl• Y iii � _ - --� i•- e.�.4� �: � .. r�•e 0' View Point 4: Existing = rl�b Location: DEC Boat Launch Distance to Site: 1,491± feet Orientation:West Visibility:Visible 0 W C 0 G7 m m o� � < �N m m m IF Elite Towers, LP 61405 Main Road, Southold View Point 4: Proposed V hb Location: DEC Boat Launch Distance to Site: 1,491± feet Orientation: West Visibility:Visible N 0 o C_- J � n 0 L a cc l < N m w (D a) 1 � Elite Towers, LP 61405 M iad, Southold J 'r 8 , tl• i . r �5..........� •� .s}:jr� 1 '�1� y ••y�,'`,lee-` �' tip T l ,•• � 6`` q. 1'°T �4i�� k. r,',y� iX '1 r 1 �'k,'�'• '��~ ��� / ,11{"" �, ,�!�'t .,,','w,.' �'� � T�': i,\," ^t"r2tS� I Aix- ,...t , / 'i l .r'p I�"''..�' 3*:\"'a vim'' !�`( r •�, iL 54 t i men " + ow AI - OIN , ► , � 4 1 '��t. y 4r}K�y� �• f `�� . �� 1 i .f.;" .ct � A t ,, �+F� � � "�*"'. � •� �1t.�;�c�yti,•I.F: t y at 4 F VAL— fiat,ORI, r,., " wsem, �•; ;r . -sir �r t, �e.� •.r.F ' dfir ;�'• .� 1 �`�.F��i, ,i� ,�' •... s ,CSR. j rsfp ( ya -,.k ,��:,i. ►, a • • •... MW ' I / � �"'' ' '.•Jty��. . '" `y a` >, i��, i►:; .yam,: 1�..r?� � � ;' ,rr�.n!G�11,�1e, e� �.�\•: �, �srA:- -. fir,- �-,�s 1 _ Y�f _ -.�_ ti j �.r. :• i r ] v r View Point 7: Existing Iib Location: Bayview Avenue Distance to Site: 3,353± feet Orientation: Southwest Visibility:Visible tV C? LCCz ` n oJC ' m Joao m 0A ea h o m D N - w m o, ' a Elite Towers, LP 61405 Main Road, Southold View Point 7: Proposed .•V hb Location: Bayview Avenue Distance to Site: 3,353± feet Orientation: Southwest Visibility:Visible N 0 0 C o—� c' n a poo rn >� w ro Bio*s Towers, LP 61405 M ad, Southold un' - -- +► s t •�A y, jy� — ■■ _..�E��-•- - - �� .rte kV— " AG�•�I���� .,-g,�. ,A,�Sy� ,A��s'IW_�-r M� +Ir'P W.Vi•.•.1w M -4-t_b E^!.r-+' +aL�+' View Point 9: Existing =' rlib Location: Goose Creek Beach Distance to Site: 9,136± feet I Orientation: Northeast Visibility:Visible oT rw CP _ wu mpft y *PA �'R... AW; dO evlo' e ` y ' Elite Towers, LP 61405 Main Road, Southold View Point 9: Proposed "vAb Location: Goose Creek Beach Distance to Site: 9,136± feet Orientation: Northeast Visibility: Visible N 0 D. D D �n m m o n - o W < �4 o m a Y > w 0 �\ k� MIT Elite Towers, LP 61405 M ad, Southold Photosimulation Location Map VIlb. Proposed Wireless Communications Facility - Albertson Marine 61405 Main Road, hamlet of Southold, Town of Southold, Suffolk County s 6r + r I � .ea 4 I �Y 2 ` 1 tit y , 9 NM=6m=" 0 0.5 Miles 0 Proposed Facility Location Photosimulation View Point Visibility RECEIVED a 1-Mile Radius Not Visible Areas predicted to have views of Visible AUG 0 9 2023 the proposed concealment pole ? 3� Zoning la-a o` Appeals Notes VHB completed a visibility analysis using Global Mapper's Viewshed Analysis tool A height of 164'-10"feet above ground surface was used for the Transmitter Elevation and 5 5 feet above ground surface was used for the Receiver Elevation.Sample spacing of 3 ft was used for the x and y axis.A DSM and DTM extracted from 2014 Long Island Lidar dated was used for the Lidar calculation. Source:Orthoimoge by Neormop(October 2022),USGS Long Island LiDAR Collection(2074), VHB(2023). ` i�, 0 hb,, Appendix RECEIVED AUGG�0,p9 2023 Zoning 8 ` -3 �+ppeals Verizon Wireless and Dish Wireless Plans 'OVA ri, N 4.-1 1- WO Ye, far, . ... ... ... vhb, Appen dix Alternative Sites Affidavit [zoning ECEIVE® UG 0 9 2023 Board of Appeals RECEIVED PLANNING BOARD: TOWN OF SOUTHOLD STATE OF NEW YORK: COUNTY OF SUFFOLK AUG 0 9 2023 i - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -X In the Matter of the Application of Elite Towers, L.P., Zoning Board of App eats New York SMSA Limited Partnership d/b/a Verizon .Wireless, DISH Wireless L.L.C. and the Southold Fire District as co-Applicants, and Budd's Pond Marina, Inc., as Owner, for all ALTERNATIVE necessary permits to construct, operate and maintain a public SITES AFFIDAVIT utility wireless communication facility at 61405 Main Road (a/k/a N.Y.S. Route 25), Southold,New York, known and designated as Suffolk County Property Tax Map No.: District 1000, Section 56, Block 3, Lot 15 (the"Property") - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - X STATE OF NEW YORK ) ss.. COUNTY OF SUFFOLK ) TANYA NEGRON,being duly sworn, deposes and says: 1. I am the managing member of Elite Towers, L.P. ("Elite"), and in my capacity as same, investigated potential locations for wireless communication facilities ("Communication Facility" or"Communication Facilities") in and around the Property. 2. I submit this affidavit in support of Elite's, New York SMSA Limited Partnership d/b/a Verizon Wireless ("Verizon Wireless")'s, DISH Wireless L.L.C. ("DISH")'s and the Southold Fire District ("Fire District") Application (the "Application") to the Town of Southold (the "Town") Planning Board in order to construct a Communication Facility. 3. The Communication Facility will be located at the Property, and will consist of the following: (1) a new 150' concealment pole ("Pole"); (2) a rectangular, fenced equipment compound (the "Equipment Compound") located in the northerly portion of the Property, towards the rear and behind the existing building; (3) on the Pole, six (6) Verizon Wireless antennas (three (3) sectors of two (2) antennas per sector), to be mounted within the Pole at 1 centerline heights of 146'-1", and 141'-2" (three (3) antennas at each height), with associated appurtenances including three (3) trilexers (one (1) per sector located below antennas); (4) three (3) DISH antennas (one (1) per sector), with associated appurtenances including six (6) diplexers (two (2) per antenna); (5) two (2) whip antennas with associated omni dimensional antennas with top heights of 164'-10" and accompanying equipment; (6) within the Equipment Compound, a 12'-0" by 20'-0" Verizon Wireless equipment area, on which will be situated Verizon Wireless' equipment cabinets and nine (9) RRH units (three (3) per sector), situated on top of a raised 8'-0" by 10'-0" prefabricated platform, with a 10'-0" x 20'-0" steel weather canopy above and one (1) GPS unit to be mounted to one of the weather canopy posts; (7) also within the Equipment Compound, a 8'-0" by 10'-0" DISH equipment area, on which will be situated equipment cabinets, nine (9) RRH units (three (3) per sector) and twelve (12) diplexers (four (4) per sector), situated on top of a raised 8'-0" by 10'-0" prefabricated platform, with one (1) GPS unit to be mounted to one of the platform's posts; (8) within the Equipment Compounds, a 8'-0" x 10'0" equipment platform with one (1) equipment cabinet; and (7) all other appurtenances, equipment, cables, conduits and wires related thereto. 4. My role for Elite includes identifying potential locations for new Communication Facilities based upon a need to remedy service deficiencies in a specified geographic area on behalf of wireless carriers including Verizon Wireless and DISH, and when appropriate, for public service entities such as the Fire District. 5. Among other information, I utilize input from wireless carriers' and the District's Radio Frequency ("RF") Engineering Departments/consultants, including: (a) the location of other existing Communication Facilities in an area; and (b) existing coverage in the area. 6. It should also be noted that the principal of the owner of the Property is William 2 RECEIVED AUG 0.9 2023 7 -3 Zoning Board of Appeals Wietzke, Deputy Fire Commissioner for the District, which also facilitated an appropriate location for the District's installation. 7. Utilizing the aforementioned criteria, it is my responsibility to ascertain potential sites for the construction of new Communication Facilities. 8. Several factors are used to determine if a potential site is a suitable location, including the location, height and clearance for the wireless communication antennas. In addition, I consider whether there is enough room to accommodate carrier(s) and public service entity equipment at the candidate Communication Facility Property. 9. I also confer with carriers' RF engineers, who determine which location, or locations, are suitable for a Communication Facility. 10. . Thereafter, I visit potential Communication Facility sites within the subject area, in order to identify a site that meets all of the aforementioned criteria, as well as meeting the requirements provided for under a municipality's code and/or regulations,to the extent feasible. 11. Once a potential site has been identified, I determine whether the property owner would be interested in leasing space to Elite in order to construct, operate and maintain a Communication Facility. 12. With regard to the applicable municipal code and/or regulations in connection . with this Application, I reviewed, among other things, the Town Code which contains provisions affecting Communication Facilities, as more fully set forth under Chapter 280, Article XVII, "Wireless Communication Facilities" (the "Wireless Ordinance"), which regulates, among other things, the siting of new wireless facilities, such as the Communication Facility contemplated by Elite, Verizon Wireless, DISH and the Fire District herein. 13. The subject area in which Verizon Wireless, DISH and.the Fire District are 3 RECET>/r-r- AUG 0 9 2023 Zoning Board of Appeals experiencing a service deficiency includes a limited number of parcels with sufficient size and appropriate current land use. In particular, the absence of many commercially-utilized parcels in the area eliminate much of the land mass in the vicinity from consideration. Further, due to the overwhelmingly flat terrain with limited tall vegetation in the area largely prevents the ability to fully screen the facility.from the surrounding area. 14. In addition to my review of the applicable Code provisions, I reviewed the Town's zoning map and aerial views of the search area within which Verizon Wireless, DISH and the Fire District are experiencing a service deficiency. 15. Once a potential site has been identified, I determine whether the property owner would be interested in leasing space to Elite in order to construct, operate and maintain a Communication Facility. 16. Therefore, in order to locate a site that complies with the Wireless Ordinance, as well as Verizon Wireless', DISH's and the Fire District's search criteria, I conducted a full and complete investigation of all properties within the vicinity, including all existing structures which can accommodate a Communication Facility. 17. Based upon this search, Elite, Verizon Wireless, DISH and the Fire District have reviewed, and rejected, the following potential sites within its search area (the "Potential Sites"), as evidenced below: 18. Port of Egypt Marine 62300 Main Road (a/k/a N.Y.S. Route 25) Southold,New York 11971 SBL: 1000-56-6-4 & 6.1 Owner: Port of Egypt Enterprises When Elite had first met with the owner several years ago, Mr. Lieblein, he had initial interest and discussed options on his property. Elite even reviewed an additional property of his a 4 RECEIVED AUG 0 92023 Zoning Board of Appeals short distance away from this site. However, after that initial meeting, follow-up calls and emails went without response, including a mailed inquiry in March, 2016. Most recently, Elite submitted a formal proposal to representatives of Port of Egypt Enterprises on March 31, 2022, by certified mail, return receipt requested (enclosed is a copy of the same). Since that time, Port of Egypt Enterprises has not responded to this request. As such, our understanding is that there would not be a feasible way to locate on Port of Egypt Enterprises' property without the owner's consent. 19. The Old Field Vineyards 120 Bay Home Road/59600 Main Road (a/k/a N.Y.S. Route 25) Southold,New York 11971 SBL: 1000-56-5-1.3 Owner: Dekka LLC Elite originally met with the owner Christian Baiz in 2011. After months of follow-up calls and emails Elite never,received a response, including a mailed inquiry in March, 2016. Most recently, Elite submitted a formal proposal to representatives of Dekka LLC on March 31, 2022, by certified mail, return receipt requested (enclosed is a copy of the same). Since that time, Dekka LLC has not responded to this request. As such, our understanding is that there would not be a feasible way to locate on Dekka LLC's property without the owner's consent. 20. Brick Cove Marina 1760 Sage Boulevard Greenport,NY 11944 SBL: 1000-57-1-38.3 Owner: Conkling Advisors, LLC Elite submitted formal proposals to representatives of Conkling Advisors, LLC on March 3, 2016, and March 31, 2022, by certified mail, return receipt requested (enclosed are copies of the same). Conkling Advisors, LLC has not responded to either of these requests. As such, our understandingis that there would not be a feasible way to locate on onklin rs s y fig'' 5 AUG ,0p9 2023 Zoning Bo d of Appeals property without the owner's consent. 21. North Fork Animal Hospital 58605 Main Road(a/k/a N.Y.S. Route 25) Southold,NY 11971, SBL: 1000-56-2-2 Owner: 58605 Route 25 Elite met with the owner, Rob Pasciotta, and had conversations with his attorney back in 2010. Mr. Pasciotta eventually sent an email passing on the project and did not move forward. More recently, Elite submitted formal proposals to representatives of North Fork Animal Hospital on March 3, 2016, and March 31, 2022, by certified mail, return receipt requested (enclosed is a copy of the same). North Fork Animal Hospital has not responded to either request. As such, our understanding is that there would not be a feasible way to locate on North Fork Animal Hospital's property without the owner's consent. 22. Elite also contacted the owners of the following sites, for which we never received any response of interest in the Communication Facility: American Legion 51655 Route 25 Southold, NY 11971 Southold Marine Center, Inc. 49900 Main Road, Route 25,- P.O. 5;P.O. Box 1664 Southold,NY Phone: (631) 765-3131 Fax: (631) 765-3147 E-mail:smemarinen_,optonline.net RECEIVED Platinum East Electric Inc. AUG 0 9 2023 47070 Route 25 � Southold,NY 11971 Zoning Bo! Ippeals 631-765-9424 6 Jamesport Country Store 1299 Main Rd Jamesport,NY 11947 (Building next to it—owner Howard Waldman) Long Season Farms DG 1017 Main Rd Aquebogue,New York 11901 A(631) 779-3360 longseasonfarmsRgmail.com Zonin 9 Ken and Laurie Jurow Bayview Market Farms 891 Main Road, Rt. 25 Aquebogue,NY 11931 631-722-3077 5629 Sound Avenue Jamesport,NY 11941 631-722-4740 Woodside Orchards 729 Main Rd. Aquebogue,NY 11931 Eastern Tire 15 Eugenes.Rd Cutchogue,NY 11935 23. Included with the foregoing offers to the above, specified properties, I also undertook a review of the entire area to assess whether there were any other viable,locations to site the Communication Facility. In the vicinity there are primarily residential, agricultural and parkland uses. Therefore, the above-targeted parcels are the ones that could best accommodate the Communication Facility in the area. 24. It should be noted that this analysis is with an eye towards the apparent 7 conflicting interests from a zoning perspective, where the potential impacts on surrounding areas must also be taken into account when reviewing applications for wireless facilities. By locating on the Property, Elite intends to site the Communication Facility within a location that would provide service, and do so by employing the least intrusive means. Specifically, the Pole is set back from.Main Road, adjacent to the Long Island Railroad tracks running along the Property line, followed by unoccupied land (part of the Paul Stoutenburgh Preserve). The existing building will also offer further screening to the south. 25. The proposed Communication Facility at the subject Property meets all potential site criteria based upon its location, wireless antenna clearance, network coverage, and availability. Further, the owner of the subject Property is the only location where a willing landlord agreed to enter lease negotiations with Elite. 26. Therefore, the proposed Communication Facility at the subject Property would provide: (1) the least intrusive means to resolve Verizon Wireless', DISH'S and the Fire District's existing service deficiency; (2) adequate and reliable network coverage for Verizon Wireless, DISH and the Fire District in the subject area; and (3) the ability to accommodate additional wireless carriers who may collocate on the proposed Communication Facility. FRECEIVED AUG 0 99 2023�, 8 CONCLUSION 27. Based on the foregoing, I respectfully request that the Planning Board grant Elite's,Verizon Wireless',DISH's and the Fire District Application in all respects. ELITE'T'OWERS,L.P. TANYA EGRO Sworn to before me this theSk day of October, 2022. RECEIVED AUG 092023 Notary Public Zonin / 9 Board of Louie Fernandes 4ppQals Notary Public-State of New York No.01FE6374706 Qualified In Suffolk county Commission Explree April 30,20 / 9 r Vhb. App RECEIVE® endix x AUG U 9 2023 7?31 Zoning Board of Appeals Amato Law Group Letter, dated November 4, 2022 �� AMATO 6bo vLD COUNTRY ROAD, 9TF'FLOOR GARDEN CITY, NY 11530 I LAW GROUP, P L L C TEL: 516.227.6363 1 FAX: 516.227.6367 I November 4, 2022 VIA ELECTRONIC DELIVERY Town of Southold RECEIVED Planning Department Town Hall Annex Building AUG 0 9 2023 54375 Route 25 -7 '9 PO Box 1179 Zoning Board of Appeals Southold,NY 11971 Attn.: Heather Lanza Re: Application(the"Application")to the Town of Southold("Town")by Elite Towers, L.P. ("Elite") in connection with the proposed public utility communication facility ("Communication Facility")to be located at 61405 Main Road,Southold,New York 11971 District 1000 Section 56 Block 3 Lot 15 (the "Property") Dear Ms. Lanza: Iri connection with the Application for the construction and maintenance of the Communication Facility on the Property,and in response to correspondence from the Planning Board Office dated February 4,2022("Town Correspondence"),herein are our responses to the comments provided by Susan Rabold of CityScape regarding her preliminary review of the proposal. Initially, we note that the requested Technical Consultant escrow account payment of $8,500 had been previously filed on February 2,2022,to which the Planning Department acknowledged receipt on February 3,2022. (Enclosed is proof of same.) Further,please note that the intention is to have the parties,Elite,Verizon Wireless,Dish and the Southold Fire District,as co-applicants as part of this Communication Facility project. With those initial items outlined, below we will address each comment as stated in the Town Correspondence. The comments from the Town Correspondence will be set forth in italics, followed by responses to each. Elite Towers LP and Verizon Wireless Non-Compliance with Article XVII. Wireless Communication Facilities Section 280-70 o D.(]) and D.(2)Applicant needs to address highest priority in writing. RESPONSE: The proposed Communication Facility is designated as Priority(e)on the list set forth at Section 280-70.D.(1). The first two on the list noted as highest priority, i.e., (a) and(b),both are 405 LEXINGTON AVENUE I CHRYSLER BUILDING,26T"FLOOR I NEIN YORE,NY 10174 1 212.485.6000 402 MAID'STREET I SUITE 204 1 METUCHEN,NJ 08840 1 732.317.1511 in connection with existing antenna support structures(whether on Town-owned properties(or(a)) or on property owned by other parties(or(b)). These options may be quickly ruled out as set forth in detail with the RF Reports produced by both DISH and Verizon Wireless. In each,it is demonstrated how significant the current coverage gap is-within the vicinity of the Property. Due the substantial size of this gap, it is clear that no existing support structures would be able to provide sufficient coverage to satisfy the need in this area. As for the next priority under(c), or new antenna support structures on Town-owned properties,upon a close search of the area,no Town-owned parcels were available that would be situated within the area to service the existing coverage gap. Finally, for Priority (d), which includes new antenna support structures on properties zoned LI or LIO, as is evidenced by the attached excerpt from the Town's Zoning Map, affixed hereto as Exhibit "A", there are no such facilities in the vicinity of the Property, which is the target location to serve the. needs of the co-applicants DISH and Verizon Wireless. Further,enclosed as part of this submission is Elite's Alternative Sites Affidavit,consisting of a report demonstrating an explanation as to each of the other sites which were investigated, and why they were ultimately rejected as viable alternatives. o F. Applicant needs to address if any of these geographic features are present. RESPONSE: Based upon a review by Azimuth Engineering P.C., Elite's site engineers, the Property does not include any of the stated geographic features. o G. Fall zones show existing structures within the 300'perimeter. Is the Applicant applying for a variance or proposing a smaller fall zone? If proposing a smaller fall zone, then the Applicant must provide a structural engineer's report addressing safety concerns. RESPONSE: Elite is seeking a variance from this provision, as the area on the Property within the fall zone would continue to be utilized as a boat storage and maintenance operation. o H. Federal aviation regulation needs to be addressed in writing. RESPONSE: Enclosed with this submission is an FAA Determination of No Hazard to Air Navigation,dated October 28,2019,confirming the absence of any issues up to 165 feet AGL and 170 feet ASML. Elite is in the process of obtaining an updated Determination, as the submitted Determination expired in 2021. This new Determination will be filed under separate cover. I o I. Property is Zoned MH so all items in "1"should be addressed in a narrative and on the construction drawings. RESPONSE: The accompanying Construction Drawings,prepared by Azimuth Engineering P.C. and with a revision date of June 1, 2022, include on Sheet Z-03 a Bulk Requirements Table which addresses the existing lot size(41,346 square feet where 80,000 square feet is required),the proposed height of the communications pole(150' plus the proposed public service whip antennas at the top, where 80' is permitted) and the distances to property lines and streets (47' where ' ' e uired . 2 RECEIVE® AUG 0 9 2023 Zoning Board of Appeals LAUG EIVED �2�3 For each of these requirements, relief is to be sought from the Town ZoninA'R1AsppeaIs o K. Applicant needs to address in writing. RESPONSE: Radio emissions fall within the maximum permissible exposure (MPE) limits established by the FCC as set forth within the enclosed Antenna Site FCC Compliance Assessment and Report,prepared by Pinnacle Telecom Group, and dated August 22, 2022. This Assessment and Report also addresses each of the requirements under this section. o. L. Applicant needs to provide the structural analysis for all shown tenants on the proposed tower. RESPONSE: The requested enclosed Structural Elevation, prepared by Raycap, and dated November 1,2019. Supporting Structural Calculations will be provided further in the process once the Town has provided further assurances regarding the location and height of the proposed pole. o M. Applicant does not address required height for the proposed tower. RESPONSE: Enclosed are Radio Frequency Reports from Verizon Wireless and DISH Network supporting the need for coverage at the heights proposed as part of the Communication Facility. While DISH Network,as a new wireless service,has wider need to provide coverage across the Long Island region, Verizon Wireless, as a more mature network, has included in its report a height analysis, confirming that the stated heights of its antennas are needed to provide the minimum necessary coverage to the surrounding area. In addition,enclosed are Radio Frequency Materials, including a letter and map from IWT, radio frequency experts for the Southold Fire District, to outline the Fire District's need for service in the vicinity. o N. Applicant needs to address in writing and on the construction drawings how all these items are addressed. RESPONSE: Elite has abided by the site design standards set forth withi this Code section,to the extent feasible based on the existing conditions. In connection with Setbacks,subsection N.(1),the proposed Communication Facility abides by the required setbacks within the underlying Marine II zoning district, as set forth on the Bulk Requirements Table of Sheet Z-03 of the enclosed Construction Drawings, prepared by Azimuth Engineering P.C., with a revision date of June 1, 2022, 2022. Further, in connection with Signs, subsection N.(2),the Communication Facility will abide by the requirements and limitations set forth therein, and Elite will file for any required permits, as may be needed, to install such signage. Regarding base station equipment shelter requirements, subsection N.(3),will not be applicable to this project,as neither Verizon Wireless nor DISH Network intend to utilize shelters for their respective equipment, instead intending on screening its ground-based equipment with privacy fencing that will be"satisfactory to the Planning Board upon consideration of impacts on adjacent properties and minimizing visual impacts." Sheet Z-08 of the Construction Drawings depict this proposal in greater detail. Similarly, Sheet Z-08 3 Y� addresses base equipment landscaping,subsection N.(4),whereby a double row of evergreen shrubs and trees shall be installed to provide a visual screen or buffer to adjoining parcels, streets and vantage points. Further, Elite agrees to maintain this vegetation for the life of the Communication . Facility. Finally, in connection with site lighting,subsection N.(5),motion-sensing lighting will be installed with sufficient protections to shield fixtures so that lighting will not extend beyond the Property lines. Details of such lighting may be found on both Sheets Z-09 and Z-12 of the Construction Drawings. Sections 280-72; 280-74.B. and C.; 280-76; o All items must be addressed by the applicant in narrative and on the construction drawings along with any supplemental documents necessary to demonstrate compliance. RESPONSE: The Construction Drawings,on Sheet Z-03,have been updated to address the items in 280-72. Regarding 280-74.B.,with the provided documentation enclosed with this package,we believe the required items are included,specifically,the FCC Compliance Report(as to(1)(a)),the Structural Elevation (as to (1)(b)),the FCC Licenses (as to (1)(c)),the RF Reports (as to (1)(d) through(f)) and the Property Deed(as to (1)(g)). The applicable provisions of 280-74.C.have also been addressed on Sheet Z-03 of the Construction Drawings. Finally,as to 280-76,the requirements thereunder are noted and shall be complied with as applicable during the life of the Communication Facility. Dish Wireless 1. Construction Drawing Comments; o Sheet T-1, "Project Directory" identifies the Tower Owner as: TBD. The Applicant needs to correct this information and provide the name of the tower owner and owner's contact information and site name. o Sheet A-2, "Antenna Schedule o Does not include the installation of the RET Cable;Applicant needs to add this to the table. o Proposed LLC Mounts (total 3) are missing from the table;Applicant needs to add this to the table. o Note 2. States, "Antenna and RRHmodels may change due to equipment availability. All equipment changes must be approved and remain in compliance with the proposed design and structural analyses. " Applicant needs to re-word the statement as follows: . . . All Any equipment changes shall be shown on revised construction drawings and in a revised structural analysis and miff shall be approved by the Tows:prior to installation. and remain in e-emplianee with thepi-epes-ed design an a RECEIVED 4 AUG 0 9 2023 FZoning Board of Appeals 2v* i RESPONSE: The requested changes have been incorporated into the enclosed, updated DISH Construction Drawings by Azimuth Engineering P.C., with a revision date of June 1, 2022. 2. Structural Analysis: This item is missing; the Applicant needs to provide the document for review. RESPONSE: The requested enclosed Structural Elevation,prepared by Raycap,and dated August 5, 2021. Supporting Structural Calculations will be provided fiirther in the process once the Town has provided further assurances regarding the location and height of the proposed pole. 3. Compliance with Article XV11. Wireless Communication Facilities o Section 280-70 o D.(2) Applicant needs to address highest priority in writing. o K. Applicant needs to address this in writing. o L. Applicant needs to provide the structural analysis. o N.(3). Applicant needs to address this in writing and on the construction drawings. o N.(4). An existing tree line/shrubs are shown north of the existingfence line adjacent the proposed ground equipment. The Applicant or Town should verb the existing landscaping is healthy and meeting the requirements of the original application for the tower. o N.(5) Applicant needs to address ground lighting at the proposed new equipment shelter in writing and on the construction drawings. RESPONSE: Please see the foregoing, corresponding responses in connection with the Elite submission in order to address each of the above-listed items. . With this submission, and,consistent with the Declaratory Ruling regarding timely siting review,In the Matter of Petition for Declaratory Ruling,WT Docket No. 08-165,by our calculation the Town utilized 23 days to provide its initial response. With this submission today, the "shot clock"recommences, allowing for 127 more days as part of the Town's review process. If you should have any questions or require anything further, please feel free to contact me. Thank you for your anticipated attention to this Application. Very truly yours, Gregory R. Alvarez Enclosure RECEIVED 5 A��r09 2023 Zoning A; d of Appeals RECEIVED Appendix X AUG 0 9 2023 -� 3 Zoning Board of Appeals Radio Frequency Reports for Verizon Wireless, Dish Wireless and Southold Fire Department L ardals RF Report Proposed Southold 4 Communication Facility 61405 Main Road, Southold,NY verizonN' September 1, 2022 C Squared Systems,LLC 65 Dartmouth Drive Aub 603-644-2800 NH 03032 Systems 3-644-2800 E-mail: sunoort((i?csquaredsN-stems.coin Table of Contents 1.0 Executive Summary.....................................................................................................................................2 2.0 Mobile Communications System Design ..................................................................................................... 2 2.1 System Considerations............................................................................................................................. 2 2.2 System Evaluation....................................................................................................................................2 3.0 Existing Network.........................................................................................................................................3 4.0 Site Need.......................................................................................................................................................4 5.0 Resulting Solution......................................................................................................................................... 5 6.0 Summary...................................................................................................................................................... 6 7.0 Qualifications, Statement of Certification, and Resume.............................................................................. 7 List of Tables Table 1: Existing Site Inventory Information......................................................................................................... 3 Table of Figures FigureA— Site Inventory .......................................................................................................................................4 Figure B—Existing 700 MHz Coverage & Site Search Ring Area........................................................................ 5 Figure C—Proposed 700 MHz Coverage............................................................................................................... 6 :EEIVED 9 202383Zoninrd Z Appeals C Squared Systems,LLC 1 September 1,2022 1.0 Executive Summary New York SMSA Limited Partnership d/b/a Verizon Wireless ("Verizon Wireless") is a public utility under the laws of the State of New York and it holds licenses from the Federal Communications Commission ("FCC") to serve the public within, among other areas, Southold,New York. Verizon Wireless' objective is to provide seamless, reliable wireless coverage to its users in accordance with the Wireless Communication and Public Safety Act of 1999.' Verizon Wireless, as a co-applicant with Elite Towers, LP'("Elite") and the Southold Fire District, is providing the following information in support of their Special Exception Application to the Town of Southold in order to construct, operate and maintain the proposed wireless telecommunications facility in Southold,New York. This report addresses Verizon Wireless'need for the proposed facility and confirms that there are no other feasible existing structures that meet Verizon Wireless' service objectives for this area. The proposed wireless telecommunications facility, to be located at 61405 Main Road, Southold, New York, is needed to provide coverage to address the existing coverage gap in the Southold area. Included in this reportis a brief summary of the site objectives and radio frequency(RF)coverage plots showing the existing coverage gap and the predicted coverage that this site will provide to the Southold area. 2.0 Mobile Communications System Desi 2.1 System Considerations Mobile telephony is a method of communication by radio consisting of mobile units,either mounted in vehicles or hand-held,that transmits to and receives signals from fixed base stations(cell sites). Base stations(cell sites)communicate with mobile wireless devices by sending and receiving signals within a small geographic area. The cell site in tum connects the mobile device to the landline telephone network. The cell sites are designed to cover a small geographic area because mobile telephony devices utilize low power. In addition, the frequencies licensed by the FCC are significantly weakened by obstructions, such as terrain, foliage and buildings which can make the coverage irregular and unreliable. Therefore, it is necessary to locate cell sites at suitable locations and heights in order to provide a seamless and reliable grade of service to the public. Seamless,reliable coverage provides users with the ability to successfully originate receive and maintain quality calls throughout a service area. Overlapping coverage is required for users to be able to move throughout the service area and reliably"hand-off'between cells to maintain uninterrupted calls. As a customer making a call in the vicinity of a cell site moves about and begins to move further away from the cell site, the coverage from that cell site becomes weaker. Unlike broadcast radio, as the customer travels, the call is transferred ("handed-off')to an adjacent cell site, if and when that cell site's signal level becomes sufficiently strong. With sufficient overlapping coverage(i.e.,when reliable coverage areas are overlapping),this process is transparent to the user. To establish the necessary distribution of cell sites and help ensure that coverage is seamless and reliable,cell sites are strategically located throughout the licensed coverage area based upon,among other things,network efficiency,topography of the land,and the location of other cell sites. When a significant service deficiency exists,the ability for effective communication is diminished and service can seriously deteriorate in that region. In these conditions, customers experience the inability to make calls, lost calls, partial conversations, unreliable/slow data connections and/or inaudible conversation. 2.2 - System Evaluation System design and evaluation is performed primarily through propagation analysis. Propagation models are widely recognized and accepted in the wireless telecommunications industry as accurate and are routinely utilized. Propagation models simulate how radio waves travel through the environment from one point to another. In order to accurately model the behavior of these radio waves,features in the environment such as elevation of the terrain(e.g.hilly or flat)and the presence of land use classifications must be taken into account. Land use classifications include such designations as buildings, water, trees, and others. Both elevation and land use data are required to accurately model the real-world behavior of a network because these factors significantly impact radio signal propagation. All propagation modeling performed for the proposed communications facility utilized high-resolution(30 meter)elevation and land use data. Since signal propagation characteristics differ through open,forested,residential or business areas,land use classifications are used to account for these differences. The model used in this evaluation employed a sophisticated diffraction based algorithm based on Fresnel-Kirchoff theory that takes into account the terrain and land use along the path from the transmitter to the receiver. A model was generated by collecting empirical data throughout the region and modifying user defined parameters utilized by the algorithm, such that a high degree of correlation between FAUG EIVED United States Code Title 47,Section 615,amended February 13,2003. 9 2023 C Squared Systems,LLC 2 3 / Se tember 1,2022 empirical and predicted results is achieved. When that is complete,the resulting propagation model software can predict coverage levels from a transmitter facility given the specific equipment configuration(antenna model,antenna height,power,etc.)of the site in question. 3.0 Existing Network Table 1 below includes Verizon Wireless' existing and approved sites that are located in the vicinity of the proposed site and details the network site-specific information used to perform the coverage analysis and generate the coverage analysis plots provided herein. Antenna Ground Distance to Centerline Elevation Southold 4 Site Name Street Address City Latitude Longitude (ft) (ft) (miles) Shelter Island 36 Menantic Rd Shelter Island 41.0664 -72.3508 160 28 3.0 Peconic Peconic Ave Peconic 41.0413 -72.4585 100.1 16 3.6 Greenport Relo Washington Ave Greenport 41.1093 -72.3677 180 7 3.0 Cutchogue East Cutchogue 41.0301 -72.4970 105.6 55.1 5.7 Cutchogue 2 31755 Main Road Cutchogue 41.0197 -72.4800 87 15.78 5.5 1176"/ Shelter Island 2 61 Cobbetts Lane Shelter Island 41.0890 -72.3280 112'6" 54 4.2 Table 1: Site Inventory Information Additionally, Figure A below shows a map of the existing and approved sites with respect to the location of the pro] communications facility. RECEIVED AUG 0 9 2023 Zoning Board o Appeals C Squared Systems,LLC 3 September 1,2022 Southold 4 Eas' an n 61405 Main Road Figure A \� Southold,NY 11971 410 04'33.79"N 720 24'21.83"W GE:3'AMSL Centerline 146'1"&14112"AGL I GREE NPORT RELO jn Subject Site Existing Site - - Planned Site - >=-80 dBm `�(`,r P R_ es een rt -<-80&>=-85 dB. 1 S�MIELTER IS ti SOUTH SHEL RISLA D Southold-) t\a•T.-�_ Y t^� .,Sltel IE PE ONIC \ –- Peconic - CUTCHOGUE 61405 Main Road creme t"tares Neighbor Sites Southold 4 Southold,NY 11971 �rhow Cott DATE:0E/91@022 Figure A-Site Inventory RECEIVED AUG 0 9 2023 -733y Zoning Board of Appeals 4.0 Site Need The below propagation maps, included as Figures B and C, illustrate the existing coverage gap in t e atifttd-area;and how the proposed communication facility at the subject site will remedy the coverage gap. There is a serious service deficiency in Verizon Wireless' wireless coverage in the Southold objective. A deficiency in coverage is evidenced by the inability to adequately and reliably transmit/receive and maintain quality calls, and establish and maintain data sessions. Due to the location and height of Verizon Wireless' existing facilities, along with the area topography, much of the areas surrounding the proposed site lack adequate reliable coverage. Figure B shows the level of existing coverage in the Southold area which is based on the minimum required signal strength for reliable in- building and in-vehicle service for 700 MHz frequencies, which are -80 dBm and -85 dBm, respectively. Verizon Wireless' knowledge, expertise and experience in designing and operating networks has led it to establish the appropriate coverage thresholds that are necessary and sufficient to provide satisfactory reliable wireless service in each of its service areas, including the Southold area. The white areas represent unreliable service areas. As depicted in this propagation map,there is currently a large portion of Southold, and the surrounding area where Verizon Wireless does not have reliable service.Figure B also depicts the site search ring area for the proposed communication facility. The proposed communication facility must be located within the search ring area in order to address the service deficiency in the Southold objective. C Squared Systems,LLC 4 September 1,2022 Southold 4 t gGb 61405 Main Road Figure B +— Greenport West s Southold,NY 11971 410 04'33.79"N 720 24'21.93"W GE:3'AMSL Centerline 146'1"&141'2"AGL Subject Site Existing Site Planned Site - >=-80 dB. -<-80&>=-85 dB. _ " SOU HOLD 4 J/ �l A ,- - " So Id, 0.5 1 miles _ F .t ttoteiu�Rt"Es L Existing and Proposed 61405 Main Road ✓ PREPAY— -___ Southold 4 Coverage-700 MHz LTE Southold,NY 11971 v rizon DATE:0811=022 Figure B-Existing 700 MHz Coverage RECEIVED AUG 0 9 2023 -783� Zoning Board o Appeals 5.0 Resulting In order to remedy the existing coverage gap,Verizon Wireless is proposing to install a wireless communications facility to be located at 61405 Main Road, Southold,New York,comprising the following: a. Six(6)panel antennas(the"Antennas")concealed within a proposed 150'-0"concealment pole(to be constructed by Elite),with Antenna centerline heights of+/- 146'-1"and 141'-2"AGL; b. An equipment platform upon which equipment cabinets and associated equipment,with canopy above,will be located,within the proposed compound(to be constructed by Elite); c. Four(4)GPS units mounted on the proposed equipment canopy;and d. All other appurtenances,devices,cables,conduits and wires related thereto,as more fully described on the site plans submitted with the application. The below propagation map included as Figure C illustrates how this proposed communications facility will remedy the coverage gap. C Squared Systems,LLC 5 September 1,2022 RECf"'rD 1 AUG 0 9 2023 -7�a� Southold a Fi ure CGre 61405 Main Road g — ort West s,,e Southold,NY 11971 e`tia� 410 04'33.79"N 4 " 720 24'21.83"W GE:3'AMSL Centerline 146'1"&141'2"AGL r �� a #` / Subject Site Existing Site Planned Site - SOUTHOLD J / - — �., SOU d, T I a � 0 0.5 1 \ Eatiating and Proposed 61405 Main RoadGENERAL NOTES PREPFARED ON Coverage-700 MHz LTE SoutttOld 4 Southold,NY 11971 Verizon✓ DATE:0b/1812022 Figure C-Proposed 700 MHz Coverage As can be seen in these plots,the proposed communications facility is ideally located to provide needed coverage to the Southold area At 700 MHz frequencies, the proposed communications facility will provide in-vehicle coverage to 3.01 square miles of area, 1,087 people, 30 businesses and 19.5 miles of roads, including 5.1 miles of main roads. It will also provide in-building coverage to 1.93 square miles of area and 597 people and 16 businesses. 6.0 Summary There are no other existing feasible structures upon which the proposed communications facility can be sited to provide the coverage requirements needed for the Southold area. The location and the proposed minimum height of the concealment pole were chosen to achieve an optimal balance between meeting coverage objectives,clearing the local obstructions,and minimizing the aesthetic impact to the community. As depicted in the enclosed plots, the proposed Verizon Wireless communications facility, with Antenna centerline heights of+/- 146'-1" and 141'-2", is ideally located to provide the much needed coverage for the Southold area, along with effective connectivity to the rest of Verizon Wireless' existing network. Our analysis confirms that the proposed communications facility will provide reliable wireless coverage and remedy the existing coverage gap in the Southold area. Without this proposed communications facility, at the height proposed, significant gaps in coverage will exist(and remain)within this area of Southold. Therefore, based upon the foregoing, the proposed communications facility should be favorably considered by the Town and the application should be granted in all respects. C Squared Systems,LLC 6 September 1,2022 7.0 Qualifications Statement of Certification and Resume I am a Radio Frequency Engineer for C Squared Systems, LLC, which has been retained by Verizon Wireless. I have ext( experience in the design and testing of Verizon Wireless' communication facilities as part of its federally licensed network in New York. For example, I have participated in the design and performance of the Verizon Wireless network in New York, participated in engineering efforts to provide a quality system build-out, evaluated zoning provisions applicable to wireless communication facilities in various communities, testified before local zoning boards in zoning hearings, prepared search areas for new installations, participated in drive tests and reviewed drive test results, participated in site visits, prepared RF designs for proposed installations, reviewed plans and prepared RF packages for zoning hearings, tested and evaluated new sites, and located and corrected system performance problem areas. I have been involved in Verizon Wireless' design of the proposed wireless communication facility at the above proposed communications facility. I have personally visited the area, reviewed coverage data for the proposed installation, and reviewed RF coverage information for Verizon Wireless' existing sites. I certify to the best of my knowledge that the statements in this report are true and accurate. September I.10T) Date Martin J. Lavin C Squared Systems, LLC RECEIVED Sworn to before me this the AUG 0 9 2023 TY 37day of '-o'--'-• Zoning Board of ppeals Notary blic C Squared Systmm;,LLC 7 September 1.20'_2 RECEIVE-;. . AUG 092023 9 2023 Systems Zon; 7$3martin.lavin@csquaredsystems.com ng Bodr d ofgppe,. , SUMMARY: Over thirty years of experience in the RF and wireless communications industry. EXPERIENCE: C Squared Systems,LLC 2008-Present Senior RF Engineer • Zoning Hearing Expert Testimony • Advanced Wireless Services RF System Design • Wireless Broadband Access Systems Engineering • Drive Test Services • Intermodulation Studies • RF Exposure Studies U.S. Cellular,Bedford,NH 2002-2008 Senior RF Engineer • West Virginia/Maryland/Pennsylvania CDMA System Design and Optimization • CDMA Capacity Planning and New Site Builds • Subject Matter Expert for E-911,Public Safety Interference Issues,Collocation,and Technology Transitions Independent Wireless One(Sprint Network Affiliate), Londonderry,NH 2000-2002 Senior RF Engineer • CDMA System Buildout in New Hampshire and Vermont • Organized Field Office • . RF System Design and Site Selection Point of Contact with Site Acquisition and Construction • Capacity Planning • System Performance Nextel,Reston,VA 1999-2000 Senior Manager—Technology Development • New Feature Development for the Motorola MEN system • Corporate RF Engineering Standards • Evaluation of international and domestic spectrum acquisition opportunities C Squared Systems,LLC 8 September 1,2022 USI,Chantilly,VA 1999 Program Manager • Software development projects in Europe and U.S., including budget and schedule responsibilil • Direct client contact for requirements gathering and proposal writing. LCC International,McLean,VA 1991-1998 Manager of Engineering • Domestic and International Cellular&PCS System Design and Buildout • Nationwide GSM Network Buildouts of Australia and New Zealand • FCC PCS Pioneer's Preference • Strategic Planning for LCC Initial Public Offering • Responsible for RF Design and Site Selection for Los Angeles MTA • Wrote network equipment RFP for two PCS MTAs • Software Product Manager for Cel1CAD,ANET,and MetroNET • Managed Drive Test Services, including all Timesheet and Expense Approval Carl T.Jones Corporation/SAIC,Springfield,VA 1987-1991 EMC/EMI Engineer • Test and Measurement consulting for FCC compliance • Broadcast(AM-FM-TV)consulting EDUCATION: University of New Hampshire—Whittemore School of Business and Economics Master of Business Administration Rensselaer Polytechnic Institute Bachelor of Science,Electrical Engineering RECEg JET AUG 0 9 2023 '51 eals Zoning B and Of APP C Squared Systems,LLC 9 September 1,2022 3000 diftf h wirele CZO/77,53 0792023 q �� peals RF Justification Report Site NYNYCO2239A 0 RF Justification Report—Site NYNYCO2239A Contents 1 INTRODUCTION..............................................................................................................................3 2 QUALIFICATIONS...........................................................................................................................3 3 WIRELESS TELECOMMUNICATIONS SYSTEMS ........................................................................3 4 PERFORMANCE METRICS............................................................................................................4 Coverage........................................................................................................................ 4 5 PERFORMANCE SOLUTIONS.......................................................................................................5 6 JUSTIFICATION FOR DISH SITE NYNYCO2339A.........................................................................5 nl�f� 61405 Main Road, Route 25,Southold, NY 11971; Dish Proposed Antenna Height= 130 feet 2 0 RF Justification Report—Site NYNYCO2239A REeRVEB 1 Introduction AUG 0 9 2023 �P63 Zoning Board of A� DISH is currently Building out Pha e 1 of its 5G network. UNIhas committed to the FCC that, by June 14, 2022, it will have deployed a core network and will offer 5G Broadband Service to at least 20%of the U.S. population. DISH has committed to the FCC that, by June 14, 2023, it will deploy a nationwide 5G network using DISH's spectrum with at least 70%of the U.S. population having access to download speeds equal to or greater than 35 Mbps. DISH submits this document in order to explain its standards and criteria for adequate signal strength, capacity, and reliability and how these standards and criteria are applicable to the Town of Southold. 2 Qualifications This report is prepared by DISH Wireless in-house RF engineering team. The team consists of experienced and properly credentialed Radio Frequency (RF) engineers, responsible for designing DISH's 5G Network in New York in order to provide adequate and effective wireless communications services in compliance with all FCC requirements, including DISH's licensure requirements. The RF engineering team uses proprietary software and tools for identifying network coverage, performance and capacity deficiencies. The team develops and implements solutions based on the analyses with the goal of maximizing network coverage, performance and efficiency. 3 Wireless Telecommunications Systems The FCC licenses a specific amount of RF spectrum to each wireless carrier and stipulates that each carrier efficiently use that spectrum to provide adequate wireless communication services to emergency services, businesses and individuals in the licensed areas. Wireless carriers achieve this mandate by continuously reusing the allocated radio frequencies throughout their licensed service area. This is accomplished by building small radio base stations, or cell sites, in a particular pattern (also known as a grid). The application of the grid concept affords a wireless carrier the ability to effectively and efficiently plan the reuse of radio frequencies. In order to provide effective coverage while maintaining an appropriate frequency reuse plan,the RF Design Engineer must perform a balancing test of all applicable technological variables. The primary variables that the engineer must balance/take into consideration are location, and the overall height of the cell sites. Too close and there is interference. Too far and calls are dropped. If a cell site is too high, it will have increased coverage but will cause interference throughout the rest of the wireless network, thereby significantly affecting network efficiency. If a cell site is too low, it will not provide effective coverage. Therefore, a properly designed wireless network design begins with strategically located cell sites. At each cell site there is a building, tower, water tank or other structure on which antennas are mounted. 61405 Main Road, Route 25,Southold, NY 11971; Dish Proposed Antenna Height= 130 feet 3 0 RECEIVED RF ustification Report—Site NYNYCO2239A 4 Performance Metrics AUG 0 9 2023 �'S3 Q The critical issue for DISH is the provisi n ot�'�a�quog4a� ,An'ial" Radio Frequency(RF) service to serve its wireless customers. The wireless industry is gove`rne3 by the Rules of the FCC. The FCC mandates in CFR 47, Parts §22.940 and §24.16 that each carrier must provide "substantial service" in its licensed service area, or risk having their license revoked. The FCC defines "substantial service" as service which is sound,favorable, and substantially above a level of mediocre service. Coverage A metric called Reference Signal Received Power("RSRP") is used to specify the coverage capabilities of wireless networks. RSRP is the average received power measured across a 5G broadband channel. RSRP is measured in units of"decibels" referenced against 1 milliwatt, or dBm.The decibel is a logarithmic unit that allows ratios to be added or subtracted. The definition formula for decibels referenced against 1 milliwatt is dBm = 10 log (P/1mW) with P measured in milliwatts. So 10 mW would be 10dBm, 100 mW would be 20dBm, etc. The service boundary of a 5G site is defined using a RSRP equating to an acceptable receiver signal threshold. This value is derived from industry standards, 5G receive signal levels and quality and acceptable signal to noise ratios, along with statistically quantifiable variations in terrain. This threshold must also take into account additional losses associated with location of the mobile user. DISH must provide adequate service to all of its users. In order to account for users within buildings, additional margin must be added to RSRP so that adequate coverage exists inside. Industry and DISH engineering standards include an additional 10dB of margin to RSRP to be used for light suburban areas, with increasing values for higher density land usage. This additional margin is also required for in-vehicle service specifically to account for increased attenuation associated with the use of hands- free headsets,where the phone is typically placed on the seat or in the center console. An industry standard RF computer-aided engineering tool is used in the design of wireless networks. This tool is used to generate a plot of RSRP that shows underlying geographic data (highways, arterial roads, etc.). The propagation map is drawn showing the region where the RSRP equates to the minimally acceptable received signal level for adequate service, as measured at the device's receiver. The propagation map depicts the RSRP of the surrounding environment including the attenuation of in-building and in-vehicle use of service and visually demonstrates existing coverage patterns. Plots can also be generated to demonstrate proposed coverage patterns. With the preceding in mind, DISH' network standard for reliable 5G wireless service for highway and rural settings is -95 dBm RSRP. Network reliability and accessibility decreases dramatically for mobile devices operating in or traveling into RF environments outside (or weaker than)the -115.21 dBm RSRP coverage boundary.Similarly, and as described above,signal level stronger than -95 dBm RSRP is used in areas where additional signal strength is needed to penetrate into buildings(e.g., city centers,dense residential, commercial and industrial type environs). 61405 Main Road, Route 25,Southold, NY 11971; Dish Proposed Antenna Height=130 feet 4 0 RF Justification Report—Site NYNYCO2239A 5 Performance Solutions When the DISH Radio Frequency Engineer identifies coverage gaps in the system or sites that have or will reach data capacity exhaustion, they issue a "Search Ring." A search area is a geographical area located within the inadequately serviced area, and it is designed such that if a wireless telecommunications facility is located within the search area,and at an appropriate height, it will likely provide the required coverage. For the most part, locations outside of the search area will fail to provide adequate service to the cell. Due to technological constraints, there is limited flexibility as to where a new facility can be located, and still function properly.The goal of the search ring is to define the permissible location for placement of a cell site that will provide adequate service in the subject cell and work properly as part of the overall network. 6 Justification for Dish Site NYNYCO2339A Dish is requesting to build a site based upon a concealed pole located at 61405 Main Road, Route 25, Southold, NY 11971,with a height of 130'AGL in order to provide new coverage in the residential and commercial areas and to offer contiguous coverage between neighboring sites. In addition, this site will provide significant offload of neighboring congested cell sites alleviating call performance issues while providing a buffer for the future traffic growth. Dish will offer good in-building coverage in areas between Middle Road & Boisseau Avenue towards West and Albertson Lane towards East. The outdoor coverage from site extends up to Horton's Lane towards West and Bayshore Road/Conking Point towards East. The accompanying coverage prediction plots exhibit the need for requested height and location. The dark green colored shade shows "excellent (deep) indoor" coverage. The light green colored shade shows"good indoor" coverage.The blue colored shade shows "normal indoor&excellent (in-vehicle) outdoor coverage. The orange colored shade shows "good outdoor" coverage. If there is no colored area, it means there is no coverage or very limited coverage. RECEIVED AUG 0 9 2023 Zonin �3 `� 9 Board of Appeals 61405 Main Road, Route 25,Southold, NY 11971; Dish Proposed Antenna Height= 130 feet 5 RF Justification Report—Site NYNYCO2239A PON CPO 08, Signal Strength levels 1! -20 to -75 dBm 1,Excellent (Deep) Indoor Coverage -75 to -85 dBm !Good Indoor Coverage -85 to-95 dBm Normal Indoor & Excellent Outdoor (In-vehicle) Coverage -95 to -115.2 dBm Good Outdoor Coverage RECEIVED AUG 0 9 2023 d rf P ZoningBoapeals 61405 Main Road, Route 25,Southold, NY 11971; Dish Proposed Antenna Height= 130 feet 6 NYNYCO2239A—Search Ring N 0 miles a ( C m Scale-1:43,450 ►, NYNYCO2241A - CL O�� o m w rD � cn ,.t . H« .as JI ► - L 25 butt � J• aherls� ' Acot ' +�• ll tt nrNrco2236A , * rn ,42 snanei his and ,.m •+� ��•NrNrfouase �� { or •�NYNYCp1N� - � .�� � `xn•M.n• Co 4BTo"Wis Is r' '., �* ,. '+ '�� �k Nv tta ®�S9Gl}�Eii��Xip•�rrti;mirra,r�s['�II; DI'41 Pro�p(),,otlHeight 1 10 teet,Addiev, 01405 Main Road, Rnutn 75. Southold,NY 11 71. N NYNYCO2239A—Gap Map L n In � C� miles p rn Scale 1A1,450 � ♦� NY,JYCO22t1A x V_ Greenp. r. r.. Z.YNYCO1231A hCo 69 CR 11S �,Jk loop f O00, 22 �NYNrco22u �oefir46 44 m"m a! " TrroCoAs � ' '"�s +� � Vit."- ITII PtopO,:c,fIIIeiKl11 V,O Ir,•1./1rl�lrt,�, ',L•�O� Main Roel, 2 +wjtF "'). fnilll olrl.NY 11071 N O O NYNYCO2239A— Propagation Map (b) � n � Coverage from Proposed Site c n O N miles //// ( fV Scale:1:47,450 111, NYNYCO2241 �+ w (D at AP,Ia � HPghtt �. 110- cot 69 YMYCO2239A $is j * Island x NY Y 22 B t we NYNYCO2240C KOniN � j L ca 4a NYNVCO21008 i �� 4� Tnxt NY IS _ ,,- 4r A Signal Strength Le,,,vels tt -20 to-75 dBm -75 to-85 dBm f CISH Ptopo,crl 1 ic-ight I '.i) feet.hddr— ..(,14M Mein Road, -85 to-95 dBm Route "outhold,NY 11971 -95 to-115.2 dBm N 0 NYNYCO2239A- Propagation Map (a) w,�27 n Coverage from Surrounding Sites Only `p o rn 10 �o Sigh 1.4 1.4511 .r �► NYNYCO2241A IK a.. 4`� YNYCO2279A _ 4 1 NYNYCO2238B } r 7 PrYNY�0 2240L~ �t . — y NYNY.0O2,11092i • .ff rr a_ Signal Strength levels 20 to-75 d8m 75 to-85 d8m -85 to-95 dBm -95 to-115.2 dBm NYNYCO2239A—Propagation Map (c) o Composite Coverage from Proposed and Surrounding Sites :3 � `n n 0 0.5 � �% *0 � miles C _.__. d O M Scale:1:43,450 - ► NYNYCO2241A Vv o M D -�� w • D lD � t11 .1 f ti �i r CR 69 � 1 j NYNYC 2279A H'�' y �i fes+ a' •_ 4 !- y r } NVNYCO227� �� NYNV 02240C .:� v Mnshomock .P 1 � r Preserve 017 NYNYG021 DOB • i�, J Signal Strength Levels M20 to-75 dBm -75to-85dBm IJI`,H Prol"' d HcfE�ht 130f-0,/ltldla;� 6It(��, I,l ln� f �, -85 to-95 dBm Rrnlf�1`. "ollfhold.NY 1 i' -95 to-115.2 dBnJ I WT Integrated Wireless Technologies, LLC Connecting Systems N Connecting People 101-1 Colin Drive Holbrook, NY 11741 631-653-6650 To: Whom it may concern RECEIVED From: Andrew T Hintze AUG 0 9 2023 Date: 24 October 2022 / 0 3� Zoning Board of Appeals Subj: Southold Fire District Radio Communications 1. The Southold Fire District has submitted, to the FCC and the Town of Southold, plans to add a second tower to their current communications network. The additional tower is required to provide a public safety quality of communications service in the areas frequented by the Fire District. These areas include the Fire District's main area of operation, the immediate mutual aid area as well as both local hospitals, Peconic Bay Medical Center and Eastern LI Hospital. Each of these areas have proven difficult to cover with the Fire Districts current communications system. While 120' would make an improvement in coverage for the Fire District, 150' is required to provide coverage at levels acceptable for Public Safety communications systems and ensure the ability for the fire fighter to communicate during critical calls. Typical coverage goals for Public Safety communications systems is 90% coverage across the geography that represents the entities primary operations area, in this case the Fire District boundaries. 2. The specific areas that require improvement are along the south shore of the north fork as well as to the far northeast. Southold Fire District's current communications systems suffer from coverage gaps primarily in the area of Cedar Beach and Paradise Point. This area has been a poor coverage area for both of the District's communications systems, Low Band and UHF. This area is home of the Fire District's Sub Station and many active members of the department. In the northeast of the Fire District's service area, the stretch of Sound Ave and the north shore is an area frequented by the Fire District and has proven a difficult area for communications. ® MOTOROLA SOLUTIONS MOTOROLA RADIO SOLUTIONS CHANNEL �� � � service , partner RE--1lanc AUG 0 9 Zoning 8oard Appeals 3. The fire districts immediate mutual aid area communications is also y the planned communications system. This is significant as each fire district relies heavily on its neighbors for backup resources and specialized response teams. Often times these backup resources are kept on standby on their own channel until needed. Changes in Emergency Medical Services Protocols by the county also increase the likelihood that resources will travel out of the district. 4. The planned communications system has been shown by both theoretical propagation maps as well as temporary suspension tests to resolve the majority of communication issues. Due to its unique location in the southeast corner of the Fire District's service area, this additional tower site will increase coverage in both areas that are affected by poor communications. 6. Since starting this project, the Fire District has temporarily located equipment at the tower in Greenport Village. Coverage has been improved but gaps remain along Sound Ave and CR 25. Additional equipment on this proposed tower is still required to meet the needs of the Fire District. If equipment is relocated from Greenport to this tower, maps created in 2020 remain accurate and reflect the plans and needs of the Fire District. 5. Please feel free to contact me at 631-653-6650 if you have any questions with regards to the above information. Respectfully 14A"W T ,A�&L JA Andrew Hintze Account Manager, Eastern Suffolk Integrated Wireless Technologies Southold Fire District Peconic DPW Tower Existing January 2020 dBm Green jx . (,reenport *-West 1 ' Ho o rw, t Bs -90 NILW;PR. T �(4 Kittitucko I'� , Nawu f f i i o V6, :3 LO r O D a) 1 m m a o roll obms Is o�� G � Wo m L Integrated Wireless Technologies Southold Fire District,Albertsons 80'Tower January 2020 or,f m 30 �5 Greens 40 t Itim y -45 Island eights C t Shelter Island i �but Shelter Island r i o n Pgconrc ou >7 Z7 rn Pindar Vu il�(: l:x�' ri 4 < ,o tr4 CD II! Cutchogue North Have 16 Integrated Wireless Technologies Southold Fire District Albertsons 120'Tower January 2020 dBM r M .45 ae rpc.r -a_• Island �1ghtS ` Ram I.' { 4 County Shelter Island ai Shelter Island Mashyi r Pres + N O � D Q7 �' n M C=) M i. . i >i _ m n, Integrated Wireless Technologies Southold Fire District Albertsons 150'Tower January 2020 darn 45 -30 y 35 Green porT ,w r1?or 00 Island rghts i� , t C Shelter Island tthelter IStnd PGi r»rc ' , 85°"` 90 IL A CL 0 r77 96 t— D raGutr.hogunNorth Haven f �rl�b RECEIVED PP endix 0 9 2023 AUG P [Zoning Board of Appeals FAA Determination of No Hazard to Air Navigation Memo dated December 12, 2022 Mail Processing Center keronautical Study No. Federal Aviation Adminisiration 2022-AEA-14712-OE Southwest Regional Office Prior Study No. Obstruction Evaluation Group 2019-AEA-11320-OE 10101 Hillwood Parkway Fort Worth, TX 76177 Issued Date: 12/12/2022 CAUG092023 ElVEO Tanya Negron Elite Towers, LP1 S Durkee Lane East Patchogue,NY 11772 f Appeals ** DETERMINATION OF NO HAZARD TO AIR NAVIGATION ** The Federal Aviation Administration has conducted an aeronautical study under the provisions of 49 U.S.C., Section 44718 and if applicable Title 14 of the Code of Federal Regulations,part 77, concerning: Structure: Tower Albertson Marine Location: Southold,NY Latitude: 41-04-33.77N NAD 83 Longitude: 72-24-21.76W Heights: 5 feet site elevation(SE) 165 feet above ground level (AGL) 170 feet above mean sea level (AMSL) This aeronautical study revealed that the structure does not exceed obstruction standards and would not be a hazard to air navigation provided the following condition(s), if any, is(are) met: Based on this evaluation, marking and lighting are not necessary for aviation safety. However, if marking/ lighting are accomplished on a voluntary basis, we recommend it be installed in accordance with FAA Advisory circular 70/7460-1 M. This determination is based, in part, on the foregoing description which includes specific coordinates, heights, frequency(ies) and power. Any changes in coordinates, heights, and frequencies or use of greater power, except those frequencies specified in the Colo Void Clause Coalition; Antenna System Co-Location; Voluntary Best Practices, effective 21 Nov 2007, will void this determination. Any future construction or alteration, including increase to heights,power, or the addition of other transmitters, requires separate notice to the FAA.This determination includes all previously filed frequencies and power for this structure. If construction or alteration is dismantled or destroyed,you must submit notice to the FAA within 5 days after the construction or alteration is dismantled or destroyed. This determination does include temporary construction equipment such as cranes, derricks, etc., which may be used during actual construction of the structure. However,this equipment shall not exceed the overall heights as indicated above. Equipment which has a height greater than the studied structure requires separate notice to the FAA. Page 1 of 3 This determination concerns t'---ffect of this structure on the safe and Pffcient use of navigable airspace by aircraft and does not reliev e.sponsor of compliance responsibilil relating to any law, ordinance, or regulation of any Federal, State, or local government body. A copy of this determination will be forwarded to the Federal Communications Commission(FCC) because the structure is subject to their licensing authority. This determination cancels and supersedes prior determinations issued for this structure. If we can be of further assistance,please contact our office at(404) 305-6068, or Dianne.Marin@FAA.GOV. On any future correspondence concerning this matter,please refer to Aeronautical Study Number 2022- AEA-14712-OE. Signature Control No: 552743193-564555951 (DNE) Dianne Marin Technician Attachment(s) Frequency Data cc: FCC RECEIVED AUG 0 9 2023 Zoning Board of A 13eals Page 2 of 3 Frequ---y Data for ASN 2022-AEA-14712-C— LOW HIGH FREQUENCY ERP FREQUENCY FREQUENCY UNIT ERP UNIT 614 698 MHz 1000 W 614 698 MHz 2000 W 698 806 MHz 1000 W 806 901 MHz 500 W 806 824 MHz 500 W 824 849 MHz 500 W 851 866 MHz 500 W 869 894 MHz 500 W 896 901 MHz 500 W 1710 1755 MHz 500 W 1850 1910 MHz 1640 W 1850 1990 MHz 1640 W 1930 1990 MHz 1640 W 1990 2025 MHz 500 W 2110 2200 MHz 500 W 2305 2360 MHz 2000 W 2305 2310 MHz 2000 W 2345 2360 MHz 2000 W 2496 .2690 MHz 500 W RECEIVED AUG 0 z9 2023 Zonrn 7 Y3 9 Board oi=,�ppeals Page 3 of 3 Vh4 • RECEIVED en i x AUG 0 9 2023 "73�g Zoning Board of Appeals Antenna Site FCC RF Compliance Assessment and Report by Pinnacle Telecom Group PiNNACIE TELECOM GROUP Professional and Technical Services RECEIVE® AUG 0 9 2023 Telecom Com sting Zoning Board of A ppeals ANTENNA SITEFCC RF COMP[iANCE ASSESSMENT ANd REPORT PREPAREd FOR ELITE TOWERS, L.P. 'AIbERTSON MARINE" SITE 61405 MAi N ROAd (RoUTE25) SOUTNold, NY AUGUST 22, 2022 14 RidcEdA[E AVENUE - SUiTE 260 • CEdAR KNolls, NJ 07927 • 973.451.1630 CONTENTS RECEIVED AUG 0 9 2023 oil Zoning Board of AgDeals INTROdUCTION ANd SUMMARY 3 ANTENNA ANd TRANSMISSION DATA 4 COMPLIANCE ANALYSIS 7 COMPLIANCE CONCLUSION 11 CERTIFICATION AppENdix A. BACkCROUNd ON ThE FCC MPE LIMIT AppENdix B. SUMMARY OF EXPERT QUA[if!CATIONS 2 RECEIVED AU78-3 G7 0 9 2023 INTRMUCTiON ANd SUMMARY Zonis / g 3�' 9 Board of q At the request of Elite Towers, L.P., Pinnacle Telecom Group haals s d Sri independent -assessment of radiofrequency (RF) levels and related FCC compliance for proposed wireless antenna operations on a new unipole to be located at 61405 Main Road (Route 25) in Southold, NY. The FCC requires wireless antenna operators to perform an assessment of potential human exposure to radiofrequency (RF) fields emanating from all the transmitting antennas at a site whenever antenna operations are added or, modified, and to ensure compliance with the Maximum Permissible Exposure (MPE) limit in the FCC regulations. In this case, the compliance assessment involves the RF levels from proposed antenna operations by DISH Wireless, Verizon Wireless and the Southold Fire District. The analysis will conservatively assume that the wireless carriers are operating at maximum capacity and maximum power in each of their FCC-licensed frequency bands. Note that FCC regulations require any future antenna collocators to assess and assure continuing compliance based on the RF effects of all proposed and then-existing antennas at the site. This report describes a mathematical analysis of RF levels resulting around the site in areas of unrestricted public access, that is, at ground level around the site. The compliance analysis employs a standard FCC formula for calculating the effects of the antennas in a very conservative manner, in order to overstate the RF levels and to ensure "safe-side" conclusions regarding compliance with the FCC . limit for safe continuous exposure of the general public. The results of a compliance assessment can be explained in layman's terms by describing the calculated RF levels as simple percentages of the FCC MPE limit. If the reference for that limit is 100 percent, then calculated RF levels higher than 100 percent indicate the MPE. limit is exceeded, while calculated RF levels consistently lower than 100 percent serve as a clear and sufficient demonstration of compliance with the MPE limit. We will also describe the overall worst-case calculated result via the "plain-English" equivalent "times-below-the-limit factor". 3 The results of the FCC RF compliance assessment in this case are as follows: ❑ A reet level around the site, the conservatively calculated maximum RF EAUG IVED leve from the proposed antenna operations is 1.4796 percent of the FCC , 9 2023 MP limit—well below the 100- percent reference for compliance. Inother iwor seven with the significant degree of conservatism in the calculations, d of Ap�� orst-case calculated RF level is still more than 65 times below the FCC limit for safe, . continuous exposure to the RF emissions from antennas. ❑ The results of the calculations provide a clear demonstration that the RF levels from the proposed antenna operations at the site satisfy the applicable criteria for controlling potential human exposure to RF fields, and the RF levels will be in clear compliance with the FCC regulations and limits concerning RF safety. Moreover, because of the conservative methodology and incorporated assumptions, RF levels actually caused by the antennas will be even less significant than the calculation results here indicate. The remainder of this report provides the following: ❑ relevant technical data on each of the proposed antenna operations at the site; ❑ descriptions of the applicable FCC mathematical models for assessing. MPE compliance, and application of the relevant technical data to those models; and ❑ the results of the analysis, and the compliance conclusion for the site. In addition, Appendix A provides background on the FCC MPE limit, along with a list of FCC references on compliance. Appendix B provides a summary of the qualifications of the expert certifying RF compliance for this site. ANTENNA ANd TRANSMISSION DATA The tables that follow provide the key compliance-related data for the proposed DISH Wireless, Verizon Wireless and Southold Fire District antenna operations. 4 DISH Wireless-- General Data RECEIVED Frequency Bands 600 MHz, 2000 MHz and 2100 MH Service Coverage Type Sectorized Antenna Type Directional PanelAntenna Centerline Hei ht AGL 130 ft. oard oAntenna Line Loss Conservative) i nored assumed 0 dB 600 MHz Antenna Data Antenna Model Max. Gain Commsco a FW-65B-R3 14.3 dBi RF channels per Sector Four 30-watt channels 1900 MHz Antenna Data Antenna Model Max. Gain Commsco a FW-65B-R3 18.4 dBi RF channels per Sector Four 40-watt channels 2100 MHz Antenna Data Antenna Model Max. Gain Commsco a FW-65B-R3 18.4 dBi RF channels per Sector Four 40-watt channels Verizon Wireless- General Data Frequency Bands 746 MHz, 869 MHz, 1900 MHz, 2100 MHz and 3700 MHz Service Coverage Type Sectorized Antenna Type Directional Panel Antenna Centerline Height AGL 141 ft. 2 in., 146 ft. 1 in. Antenna Line Loss Conservatively ignored (assumed 0 dB) 746 MHz Antenna Data Antenna Model (Max. Gain) =JMA Wireless MX06FIT465-02 (13.4 dBi) RF Channels per Sector Four 40-watt channels 869 MHz Antenna Data Antenna Model (Max. Gain) JMA Wireless MX06FIT465-02 (13.5 dBi) RF Channels per Sector Four 40-watt channels 1900 MHz Antenna Data Antenna Model (Max. Gain) JMA Wireless MX06FIT465-02 (16.8 dBi) RF Channels per Sector Four 40-watt channels 2100 MHz Antenna Data Antenna Model (Max. Gain) JMA Wireless MX06FIT445-02 (18.0 dBi) RF Channels per Sector Four 40-watt channels 3700 MHz Antenna Data Antenna Model (Max. Gain) JMA Wireless MX08FIT265-01 (17.1 dBi) RF Channels per Sector Two 50-watt channels 5 i The Southold Fire District is licensed by the FCC to operate in the 46 MHz, 460 MHz and 465 MHz frequency bands. In the 46 MHz frequency band, they use an maximum effective radiated power (ERP) of 30 watts. In the 460 MHz frequency band, they use ERPs of 2.5 watts, 25 watts, 35 watts and 50 watts. Lastly, the ERPs in the 465 MHz band are 2.5 watts, 4 watts, 10 watts and 70 watts. The antenna vertical-plane radiation pattern is used in the calculations of RF levels at ground level around a site. By way of illustration, Figure 1 that follows shows the vertical-plane radiation pattern of the antenna model to be used by DISH Wireless in the 600MHz frequency band. Note that in this type of diagram,the antenna is effectively pointed at the three o'clock position (the horizon) and the relative strength of the pattern at different angles is described using decibel units. The use of a decibel scale to describe the relative pattern at different angles incidentally tends to visually understate the actual focusing effects of the antenna. Where the antenna pattern reads 20 dB, for example, the relative RF energy emitted at the corresponding downward angle is 1/100th of the maximum that occurs in the main beam (at 0 degrees); at a 30-dB point, the level is 1/1,000th of the maximum. Figure 1.JIMA Wireless FVV-65B-R3 Antenna—600 MHz Vertical-plane Pattern RECEIVED AUG 0 9 2023 _713 Zoning Board'of App als 0 deg horizon 5 dB'/division 6 RECEIVED COMPLIANCE ANALySis AUG U 9 2023 FCC Office of Engineering and Technology Bulletin 65 ("OET Bulletn �nvi d o �3? Appeals guidelines for mathematical models to calculate the RF levels at ious-point around transmitting antennas. At street-level around an antenna site (in what is called the "far field" of the antennas), the RF levels are directly proportional to the total antenna input power and the relative antenna gain in the downward direction of interest - and the levels are otherwise inversely proportional to the square of the straight-line distance to the antenna. Conservative calculations also assume the potential RF exposure is enhanced by reflection of the RF energy from the. intervening ground. Our calculations will assume a 100% "perfect", mirror-like reflection, the worst-case approach. _ The formula for street-level compliance assessment for any given antenna operation is as follows: -MPE% _ (100 *TxPower* 10 (Gmax-Vdisc/10) *4 ) / (MPE *47" R2) where MPE% = RF level, expressed as a percentage of the MPE limit applicable to continuous exposure of the general public 100 = factor to.convert the raw result to a percentage TxPower = maximum net power into antenna sector, in milliwatts, a function of the number of channels per sector, the transmitter power per channel, and line loss 10 (cmax-Vdisc/10) = numeric equivalent of the relative antenna gain in the downward direction of interest; data on the antenna vertical-plane pattern is taken from manufacturer specifications 4 = factor to account for a 100-percent-efficient energy reflection from the intervening ground, and the squared relationship between RF field strength and power density (22 = 4) MPE = FCC general population MPE limit l R = straight-line distance from the RF source to the point of interest, centimeters 7 The MPE% calculations are performed out to a distance of 500 feet from the facility to points 6.5 feet (approximately two meters, the FCC-recommended standing height) off the ground, as illustrated in Figure 2, below. antenna ! EZoning IVED height P from III! R 9 2023 antenna �bottom to 6.5' rd of Appeals above ground level 0 500 Ground Distance D from the site Figure 2. Street-level MPE% Calculation Geometry It is popularly understood that the farther away one is from an antenna, the lower the RF level—which is generally but not universally correct. The results of MPE% calculations fairly close to the site will reflect the variations in the vertical- plane antenna pattern as well as the variation in straight-line distance to the antennas. Therefore, RF levels may actually increase slightly with increasing distance within the range of zero to 500 feet from the site. As the distance approaches 500 feet and beyond, though, the antenna pattern factor becomes less significant, the RF levels become primarily distance-controlled, and as a result the RF levels generally decrease with increasing distance, and are well understood to be in compliance. FCC compliance for a collocated antenna site is assessed in the following manner. At each distance point along the ground, an MPE% calculation is made for each antenna operation (including each frequency band), and the sum of the individual MPE% contributions at each point is compared to 100 percent, the normalized reference for compliance with the MPE limit. We refer to the sum of the individual MPE% contributions as "total MPE%", and any calculated total MPE% result exceeding 100 percent is, by definition, higher than the FCC limit and represents 8 non-compliance and a need to mitigate the potential exposure. If all results are consistently below 100 percent, on the other hand, that set of results serves as a clear and sufficient demonstration of compliance with the MPE limit. The following conservative methodology and assumptions are incorporated into the MPE% calculations on a general basis: 1. The antennas are assumed to be operating continuously at maximum power in each frequency band. 2. The power-attenuation effects of shadowing or other obstructions to the line-of-sight path from the antenna to the point of interest are ignored. 3. The calculations intentionally minimize the distance factor(R) by assuming a 6'6" human and performing the calculations from the bottom (rather than the centerline) of each operator's lowest-mounted antenna, as applicable. 4. The potential RF exposure at ground level is assumed to be 100-percent enhanced (increased) via a "perfect mirror-like field reflection from the intervening ground. The net result of these assumptions is to intentionally and significantly overstate the calculated RF levels relative to the RF levels that will actually occur—and the purpose of this conservatism is to allow"safe-side" conclusions about compliance with the MPE limit. The table that follows provides the results of the MPE% calculations for each antenna operation, with the worst-case result highlighted in bold in the last column. RECEIVED AUG 0 9 2023 X931 Zoning E'; '_. c .: :'aIs 9 DISH Verizon Ground Wireless Wireless Southold FD Total MPE% Distance(ft) MPE% MPE% MPE% 0 0.0538 0.0694 0.0007 0.1239 20 0.0943 0.1128 0.0293 0.2364 40 0.2337 0.1027 0.0930 0.4294 60 0.0674 0.0590 0.1448 0.2712 80 0.1237 0.4140 0.1702 0.7079 100 0.4487 0.7217 0.1643 1.3347 120 0.4747 0.7797 0.1466 1.4010 140 0.3197 0.8514 0.1325 1.3036 160 0.2389 1.0894 0.1253 1.4536 180 0.2467 1.1133 0.1196 1.4796 200 0.2436 0.6995 '0.1196 1.0627 220 0.2391 0.2340 0.1162 0.5893 240 0.2484 . 0.1522 0.1234 0.5240 260 0.1927 0.1960 0.1243 0.5130 280 0.1670 0.2071 0.1187 0.4928 300 0.1889 0.2451 0.1217 0.5557 320 0.1724 0.2398 0.1201 0.5323 340 0.1426 0.1857 0.1249 0.4532 360 0.1244 0.1446 0.1231 0.3921 380 0.1349 0.0867 0.1205 0.3421 400 0.1707 0.0425 0.1197 0.3329 420 0.1560 0.0341 0.1187 0.3088 440 0.1980 0.0220 0.1092 0.3292 460 0.2447 0.0458 0.1075 0.3980 480 0.2259 1 0.0930 0.1062 0.4251 500 0.2875 0.0859 0.0985 0.4719 As indicated, even with the significant degree of conservatism built into the calculations, the maximum calculated RF level is 1.4796 percent of the FCC general population MPE limit - well below the 100-percent reference for compliance. A graph of the overall street-level calculation results, provided on the next page, provides a clearer visual illustration of the relative insignificance of the calculated RF levels. The line representing the overall calculation results shows an obviously clear, consistent margin to the FCC MPE limit. F ECEIVED� �32023 Board of Appeals 10 a COMPLIANCE ASSESSMENT RESULTS Normalized FCC MPE Limit Total MPE% Results 120 W 100 Q. 80 O a 60 as � 40 O. 20 0 0 100 200 300 400 500 Distance (ft) RF-ri= r: AUG 0 9 2023 -7B 3 q COMPHANCE CONCLUSION Zoning Board of Appeals According to the FCC, the FCC MPE limit has been constructed in such a manner that continuous human exposure to RF emissions up to and including 100 percent of the MPE limit is acceptable and safe. As described, the analysis in this case shows that the maximum, calculated RF level from the proposed antenna operations at the site is 1.4796 percent of the FCC MPE limit. In other words, the worst-case calculated RF level from the antenna operations is more than 65 times below the limit established as safe for continuous human exposure to the RF emissions from antennas. The results of the calculations provide a clear demonstration of compliance with the FCC MPE limit. Moreover, because of the conservative calculation methodology and operational assumptions we applied in the analysis, RF levels actually caused by the antennas will be even less significant than the calculation results here indicate. 11 CERTIFICATION It is the policy of Pinnacle Telecom Group that all FCC RF compliance assessments are reviewed, approved, and signed by the firm's Chief Technical Officer who certifies as follows: 1. 1 have read and fully understand the FCC regulations concerning RF safety and the control of human exposure to RF fields (47 CFR 1.1301 et seq). kj 2. To the best of my knowledge, the statements and information disclosed in this report are true, complete and accurate. 3. The analysis of site RF compliance provided herein is consistent with the applicable FCC regulations, additional guidelines issued by the FCC, and industry practice. 4. The results of the analysis indicate that the subject antenna operations will be in compliance with the FCC regulations concerning the control of potential human exposure to the RF emissions from antennas. 8/22/22 Daniel ollins Date Chief nicalOfficer Pinnacle Telecom Group, LLC E V ED 23ro'7ppeats 12 AppENdix A. BAckgROUNd ON ThE FCC MPE LIMIT FCC Rules and Regulations As directed by the Telecommunications Act of 1996,the FCC has established limits for maximum continuous human exposure to RF fields. The FCC maximum permissible exposure (MPE) limits represent the consensus of federal agencies and independent experts responsible for RF safety matters. Those agencies include the National Council on Radiation Protection and Measurements (NCRP), the Occupational Safety and Health Administration (OSHA), the National Institute for Occupational Safety and Health (NIOSH), the American National Standards Institute (ANSI), the Environmental Protection Agency (EPA), and the Food and Drug Administration (FDA). In formulating its guidelines, the FCC also considered input from the public and technical community — notably the Institute of Electrical and Electronics Engineers (IEEE). The FCC's RF exposure guidelines are incorporated in Section 1.301 et seq of its Rules and Regulations (47 CFR 1.1301-1.1310). Those guidelines specify MPE limits for both occupational and general population exposure.. The specified continuous exposure MPE limits are based on known variation of human body susceptibility in different frequency ranges, and a Specific Absorption Rate (SAR) of 4 watts per kilogram, which is universally considered to accurately represent human capacity to dissipate incident RF energy (in the form of heat). The occupational MPE guidelines incorporate a safety factor of 10 or greater with respect to RF levels known to represent a health hazard, and an additional safety factor of five is applied to the MPE limits for general population exposure. Thus, the, general population MPE limit has a built-in safety factor of more than 50. The limits were constructed to appropriately protect humans of both sexes and all ages and sizes and under all conditions—and continuous exposure at levels equal to or below the applicable MPE limits is considered to result in no adverse health effects or even health risk. The reason for two tiers of MPE limits is based on an understanding and assumption that members of the general public are unlikely to have had appropriate RF safety training and, may not be aware of the exposures they receive; occupational exposure in controlled environments, on the other hand, is assumed to involve individuals who have had such training, are aware of the exposures; and know how to maintain a safe personal work environment. The FCC's RF exposure limits are expressed in two equivalent forms, using alternative units of field strength (expressed in volts per meter, or V/m), and power density (expressed in milliwatts per square centimeter, or mW/cm2). The table on the next page lists the FCC limits for both occupational and general population exposures, using the mW/cm2 reference, for the different radio frequency ranges. R EC e V7D AUG 0 9 2023 Zoning Board of Appeals 13 Frequency Range(F) Occupational Exposure General Public Exposure (MHz) (mW/cm2) (MW/CM2) 0.3 - 1.34 100 100 1.34 -3.0 100 180/ F2 3.0 - 30 900/ F2 180/ F2 30 -300 1.0 0.2 300 - 1,500 F/300 F/ 1500 1,500 - 100,000 5.0 1.0 The diagram below provides a graphical illustration of both the FCC's occupational and general population MPE limits. Power Density RECEIVED (MW/cm2) AUG 0 9 2023 3� 100' Occupational Zoning Board of Appeal ------ General Public 5.0 1.0 0.214 --- I I I I I I Y I 0.3 1.34 3.0 30 300 1,500 100,000 Frequency (MHz) Because the FCC's MPE limits are frequency-shaped, the exact MPE limits applicable to the instant situation depend on the frequency range used by the systems of interest. The most appropriate method of determining RF compliance is to calculate the RF power density attributable to a particular system and compare that to the MPE limit applicable to the operating frequency in question._The result is usually expressed as a percentage of the MPE limit. 14 For potential exposure from multiple systems, the respective percentages of the MPE limits are added, and the total percentage compared to 100 (percent of the limit). If the result is less than 100, the total exposure is in compliance; if it is more than 100, exposure mitigation measures are necessary to achieve compliance'. Note that the FCC "categorically excludes" certain types of antenna facilities from the routine requirement to specifically (i.e., mathematically) demonstrate compliance with the MPE limit. Among those types of facilities are cellular antennas mounted on any type of tower, when the bottoms of the antennas are more than 10 meters (c. 32.8 feet) above ground. The basis for the categorical exclusion, according to the FCC, is the understanding that because of the low power and the directionality of the antennas, such facilities — individually and collectively — are well understood to have no significant effect on the human environment. As a result, the FCC automatically deems such facilities to be in compliance. In addition, FCC Rules and Regulations Section 1.1307(b)(3)describes a provision known in the industry as "the 5% rule". It describes that when a specific location — like a spot on a rooftop — is subject to an overall exposure level exceeding the applicable MPE limit, operators with antennas whose MPE% contributions at the point of interest are less than 5% are exempted from the obligation otherwise shared by all operators to bring the site into compliance, and those antennas are automatically deemed by the FCC to satisfy the rooftop compliance requirement. FCC References on Compliance 47 CFR, FCC Rules and Regulations, Part 1 (Practice and Procedure), Section 1.1310 (Radiofrequency radiation exposure limits). FCC Second Memorandum Opinion and Order and Notice of Proposed Rulemaking.(FCC 97-303), In the Matter of Procedures for Reviewing Requests for Relief From State and Local Regulations Pursuant to Section 332(c)(7)(8)(v) of the Communications Act of 1934 (WT Docket 97-192), Guidelines for Evaluating the Environmental Effects of Radiofrequency Radiation (ET Docket 93-62), and Petition for Rulemaking of the Cellular Telecommunications Industry Association Concerning Amendment of the Commission's Rules to Preempt State and Local Regulation of Commercial Mobile Radio Service Transmitting Facilities, released August 25, 1997. FCC First Memorandum Opinion and Order, ET Docket 93-62, In the Matter of Guidelines for Evaluating the Environmental Effects of Radiofrequency Radiation, released December 24, 1996. FCC Report and Order, ET Docket 93-62, In the Matter of Guidelines for Evaluating the Environmental Effects of Radiofrequency Radiation, released August.1, 1996. RECEIVED AUG 0 9 2023 Zonina Boa �� M_ of A�eals FCC Office of Engineering and Technology (OET) Bulletin 65, "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields", Edition 97-01, August 1997. RECEIVE® AUG 0 9 2023 -Ta3� Zoning Board of Appeals 16 ApPENdIX B. SUMMARY OF EXPERT QUALIFICATIONS Daniel J. Collins, Chief Technical Officer, Pinnacle Telecom Group, LLC Synopsis: .40+years of experience in all aspects of wireless system engineering, related regulation, and RF exposure • Has performed or led RF exposure compliance assessments on more than 20,000 antenna sites since the latest FCC regulations went into effect in 1997 • Has provided testimony as an RF compliance expert more than 1,500 times since 1997 • Have been accepted as an FCC compliance expert in New York, New Jersey, Connecticut, Pennsylvania and more than 40 other states, as well as by the FCC Education: • B.E.E., City College of New York(Sch. Of Eng.), 1971 • M.B.A., 1982, Fairleigh Dickinson University, 1982 • Bronx High School of Science, 1966 Current Responsibilities: • Leads all PTG staff work involving RF safety and FCC compliance, microwave and satellite system engineering, and consulting on wireless technology and regulation Prior Experience: • Edwards& Kelcey, VP—RF Engineering and Chief Information Technology Officer, 1996-99 • Bellcore (a Bell Labs offshoot after AT&T's 1984 divestiture), Executive Director—Regulation and Public Policy, 1983-96 •AT&T(Corp. HQ), Division Manager—RF Engineering, and Director—Radio Spectrum Management, 1977-83 •AT&T Long Lines, Group Supervisor—Microwave Radio System Design, 1972-77 Specific RF Safety/ . Involved in RF exposure matters since 1972 Compliance Experience: • Have had lead corporate responsibility for RF safety and compliance at AT&T, Bellcore, Edwards& Kelcey, and PTG •While at AT&T, helped develop the mathematical models for calculating RF exposure levels • Have been relied on for compliance by all major wireless carriers, as well as by the federal government, several state and local governments, equipment manufacturers, system integrators, and other consulting/engineering firms Other Background: •Author, Microwave System Engineering(AT&T, 1974) •Co-author and executive editor,A Guide to New Technologies and Services (Bellcore, 1993) • National Spectrum Management Association (NSMA)— former three-term President and Chairman of the Board of Directors; was founding member,.twice-elected Vice President, long-time member of the Board, and was named an NSMA Fellow in 1991 • Have published more than 35 articles in industry magazines RE''E, fir- AU'G7 0 9 2023 I 3 .3—) 17. Zoning Board of Appeals Vhb,; • RECEIVED I x H. AUG 0 9 2023 2ALppeals Zoning Determination from the New York State Office of Parks, Recreation and Historic Preservation Megan Ricks Gomez From: towernotifyinfo@fcc.gov Sent: Thursday, November 16, 2017 10:45 AM To: Megan'Ricks Gomez Subject: Section 106 Notification of SHPOlTHPO Concurrence- Email ID#2600 69 RECEIVED This is to notify you that the Lead SHPO/THPO has concurred with the following filing: AUG 0 9 2023 Date of Action: 11/16/2017 Direct Effect: No Historic Properties in Area of Potential Effects (APE) zoning Board f 3� Visual Effect: No Adverse Effect on Historic Properties in APE of Appeals Comment Text: The NYSHPO concurs with the recommended effect finding.Reviewed by Christina Vagvolgyi, NYSHPO. File Number: 0007963465 TCNS Number: 162082 Purpose: New Tower Submission Packet Notification Date: 7AM EST 10/19/2017 Applicant: Elite Towers, LP Consultant: EnviroBusiness Inc. d/b/a EBI Consulting (EBI#6117004802) Positive Train Control Filing Subject to Expedited Treatment Under Program Comment: No Site Name: in Marine Site Address: 61405 Main Road Detailed Description of Project: 6117004802 Proposed construction of a new telecommunications monopole and compound resulting in ground disturbance Site Coordinates: 41-4-33.0 N, 72-24-22.2 W City: Southold County: SUFFOLK State:NY Lead SHPO/THPO: New York State Historic Preservation Office NOTICE OF FRAUDULENT USE OF SYSTEM, ABUSE OF PASSWORD AND RELATED MISUSE Use of the Section 106 system is intended to facilitate consultation under Section 106 of the National Historic Preservation Act and may contain information that is confidential, privileged or otherwise protected from disclosure under applicable laws. Any person having access to Section 106 information shall use it only for its intended purpose. Appropriate action will be taken with respect to any misuse of the system. 1 . b,, M Appendix One-Mile Visibility Study Photographs RECEIVED AUG 0 9 2023 and of Appeals Photograph 7 View of the(ocatioo of the proposed concealment pole on the S ubjec;` property, facing north �z t. .. c�-fit'• Photograph 2: View from Goose Creek Beach, 9,74 7 feet south of the Subject Property,facing north. Page I of 9 ,. fP v Ott r r7 i 1 it Photograph 3: View from the corner of Orchard Road and Arshamomaque Avenue,3,067±feet southwest of the Subject Property,facing northeast. • 4 T t[ I&L LK� Photograph 4: View from Willow Point Road, 7,293± feet southeast of the Subject Property,facing northwest. RECEIVED Page 2 of 9 AUG 0 9 2023 7(1^inn �r.�.•rl rf /1 o-..:..n-,I�,. A w w lk ' ATM t Photo ra h 6.View from Budds Pond Road, 731 t feet south of the Subject Property,facing north. K .i RECEIVE AUG p g 2023 .^ boa d of PP Zoning - Photograph 7: View from Main Road, 1,110±feet southwest of the Subject Property, facing northeast as � Photograph 8: View from Old Main Road, 1,934± feet northeast of the Subject Property,facing southwest. Page 4 of 9 ReCEIVED AUG 1 _ : Board of APP•• � J Photograph • from I boat launchon Old Main '•rr 7,576±feet eastof r • •r facing D s 4— Photograph I from r '•rr 4,638±feet northeastof rProperty, r r southwest RECEIVED AUG -V3 Zoning Board o Photogra h 77: View from Doi hin Drive,3,560± feet northeast of the Sub'ect Pro a facin southwest. Photograph 72: View from Main Road,2,921±feet northeast of the Subject Property,facing southwest. Page 6 of 9 � r ,4� Rte'"' =iVE L_V1-- AUG 092 � Zoning Board Photograph 13: View from Main Road, 2,594± feet northeast of the Subject Property,facin southwest. � >l I a�! fin' L-aw- 1!V� y4 �2r"t 3wv'`^mac Photograph 14: View from Laurel Avenue, 1,955±feet southwest of the Subject Property,facing northeast. Page 7 of 9 a�L.. I\j ID 39 Photo r rrh 75.-View from Pond Avenue, 7,603± • of the Su ct Prore facinrsoutheast Pe.' Photograph •: View from :ryview Avenue, 3,352±feet northeastof the SubjectProperty,facing southwest Page of 9 666 OLD COUNTRY ROAD, 9"' FLOOR GARDEN CITY, NY 11530 LAW G RC U P, P L L C TEL:516.227.6363 1 FAX: 516.227.6367 RECEIVED August 9, 2023 AUG 0 9 2023-7B 3� Zoning Board of appeals VIA HAND DELIVERY Town of Southold Zoning Board of Appeals Town Hall Annex Building 54375 Route 25 PO Box 1179 Southold,NY 11971 Re: Area Variance Application (the"Application")to the Town of Southold("Town") Zoning Board of Appeals("ZBA")by Elite Towers,L.P.("Elite"),New York SMSA Limited Partnership d/b/a Verizon Wireless ("Verizon Wireless"), DISH Wireless LLC("DISH"),and the Southold Fire District in connection with the proposed public utility communication facility ("Communication Facility") to be located at 61405 Main Road, Southold,New York 11971,District 1000, Section 56,Block 3,Lot 15 (the"Property") Dear ZBA Representative: In connection with the Application for the construction and maintenance of the Communication Facility on the Property,and in follow up to the Notice ofDisapproval issued by the Town Building Department on January 18, 2023 (which we ask to be updated consistent with our discussion regarding the new lot coverage calculation eliminating the need for relief from same), enclosed are nine (9) sets of the following materials in support of the Application to the ZBA: 1. Notice of Disapproval; 2. Application to the Town of Southold Board of Appeals—Area Variance, signed by Elite, Verizon Wireless,DISH and the Southold Fire District; 3. Applicant's Project Description,prepared by VHB; 4. Questionnaire for Filing with your ZBA Application Form,signed by Elite,Verizon Wireless, DISH and the Southold Fire District; 5. Agricultural Data Statement, signed by Elite Towers; 6. Authorization, signed by the Property owner; 7. Transactional Disclosure Form, signed by Elite; 8. Transactional Disclosure Form, signed by Verizon Wireless; 9. Transactional Disclosure Form, signed by DISH; 10. Transactional Disclosure Form, signed by the Southold Fire District; 11. Transactional Disclosure Form, signed by the Property owner; 405 LEXINGTON AVENUE I CHRYSLER BUILDING,26.1"FLOOR I NEW YORK,NY 10174 1 212.485.6000 402 MAIN STREET I SUITE.204 1 METUCHEN,NJ 08840 1 732.317.1511 REC"E VED AUG 0 9 2023 7 e3301 12. Transactional Disclosure Form, signed by Amato Law Group, PL C?oning Board of Appeal' 13. Property Photos;refer to page 4 of the Planning Report; 14. Property Surveys; 15. Drawings,prepared by Azimuth Engineering P.C.,and revised as of June 15, 2023; 16. Title Report for the Property, including Covenants and Restrictions; 17. Town Property Card; 18. LWRP Consistency Assessment Form,prepared by VHB; 19. EAF,prepared by VHB, and dated June 7, 2023; 20. RF Justification Report,prepared by DISH Wireless; 21. RF Report, prepared for Verizon Wireless by C Squared Systems,LLC, dated May 30, 2023; 22. Planning, Zoning and Visual Impact Analysis, prepared by VHB, and dated June, 2023; and 23. Check, in the amount of $1,000, payable to the Town, representing the required Application fee. Shot Clock As noted within our January 9, 2023, correspondence (a copy has been enclosed with this submission),the shot clock recommenced,and ran until the release of Notice of Disapproval. As an additional nine(9)days elapsed,by our calculation 108 days remain in connection with the 180-day "shot clock"set forth within In the Matter of Petition for Declaratory Ruling,WT Docket No. 08- 165, issued by the FCC on November 18, 2009. Please note that today we have concurrently filed applications with the Planning Board and the Board of Town Trustees in connection with this project. Therefore,we seek your assistance in administering this Application in a timely fashion consistent with the shot clock. If you should have any questions or require anything further, please feel free to contact me. Thank you for your continuing attention to this Application. Very truly yours, �Wh Gregory R. Alvarez Enclosures cc: Elite(via email, w/out enclosures) Verizon Wireless (via email, w/out enclosures) DISH (via email, w/out enclosures) Southold Fire District (via email, w/out enclosures) 2 RECEI\jF-® AUG 31`2023 �.$3of Appeals Zoning Board August 31, 2023 VL4 IIAND DELIVERY Town of Southold Zoning Board of Appeals Town Hall Annex Building 54375 Route 25 PO Box 1179 Southold,NY 11971 Attn.: Elizabeth Sakarellos, Senior Office Assistant Re: Area Variance Application (the "Application") to the Town of Southold ("Town") Zoning Board of Appeals("ZBA")by Elite Towers,L.P.("Elite"),New York SMSA Limited Partnership d/b/a Verizon Wireless ("Verizon Wireless"), DISH Wireless LLC("DISH"),and the Southold Fire District in connection with the proposed public utility communication facility ("Communication Facility") to be located at 61405 Main Road, Southold,New York 11971,District 1000, Section 56, Block 3, Lot 15 (the"Property") Dear Ms. Sakarellos: In connection with the Application for the construction and maintenance of the Communication Facility on the Property,and in follow up to the filing on August 9,2023,as well as your email of August 16th outlining additional requested items, enclosed are nine (9) sets of the following additional materials in support of the Application to the ZBA: 1. Agricultural Data Statements, signed by Elite, Verizon Wireless, DISH and the Southold Fire District,and updated to incorporate parcels with active farm operations within 500' of the Property; 2. Authorization for DISH, signed by the property owner; and 3. Check, in the amount of$500, payable to the Town, representing the additional requested Application fee. Shot Clock As noted within our August 9,2023,correspondence,the shot clock recommenced from the date of filing, stopping again upon receipt of your email, as well as the August 18th letter from the Planning Department outlining their additional requests to our submission to same. As an additional nine(9)days elapsed,by our calculation 99 days remain in connection with the 180-day"shot clock" set forth within In the Matter of Petition for Declaratory Ruling,WT Docket No. 08-165,issued by the FCC on November 18, 2009. Please note that the applications with the Planning Board and the Board of Town Trustees in connection with this project are being reviewed concurrently. Therefore,we seek your continuing assistance in administering this Application in a timely fashion consistent with the shot clock. If you should have any questions or require anything further,please feel free to contact me. Thank you for your continuing attention to this Application. Very truly yours, C-1.� Gregory R. Alvarez Enclosures cc: Elite (via email, w/out enclosures) Verizon Wireless (via email, w/out enclosures) DISH (via email, w/out enclosures) Southold Fire District(via email, w/out enclosures) 2 ZBA CHECK FEES - 2023 Funding Account - B2110.10 DATE NAME ZBA FILE# FEE CHECK# DATE SENT TO TCO 7840 8/29/2023 Finnegan Law for Meiri,Yehuda $750.00 1294 9/1/2023 Elite Towers for Budds Pond 8/30/2023 Marina Inc.Albertson Marina 7839 $1,000.00 3028 9/1/2023 Brooke P. Dolan for Budds Pond 8/30/2023 Marina Inc.Albertson Marina 7839 $250.00 200 9/1/2023 8/30/2023 Elite Towers for Budds Pond 7839 $500.00 3046 9/1/2023 $2,500.00 RECEIVE® SEP - 5 2023 Southold 'Town Clary Tbwn of§outhold P.O Box 1179 Southold, NY 11971 * * * RECEIPT * * * Date: 09/06/23 Receipt#: 315096 Quantity Transactions Reference Subtotal 1 ZBA Application Fees 7839 $1,750.00 1 ZBA Application Fees 7840 $750.00 Total Paid: $2,500.00 Notes: Payment Type Amount Paid By CK#200 $250.00 Dolan, Brooke P CK#3028 $1,000.00 Elite Towers, LP CK#3046 $500.00 Elite Towers, LP CK#1294 $750.00 Finnegan Law, P.C. Southold Town Clerk's Office 53095 Main Road, PO Box 1179 Southold, NY 11971 Name: Meiri, Yehuda 955 Lilac Ln Cutchogue, NY 11935 Clerk ID: JENNIFER Internal ID:7840 4V Y f908b203-bd63-423e-a024-2db22f103ecd kimf@southoldtownny.gov ( J 9 AFFIDAVIT OF PUBLICATION The Suffolk Times LEGAL NOTICE SOUTHOLD TOWN ZONING BOARD OF APPEALS THURSDAY,OCTOBER 5, 2023 at 10:00 AM PUBLIC HEARINGS NOTICE IS HEREBY GIVEN, pursuant to Section 267 of the Town Law and Town Code Chapter 280 (Zoning),Town of Southold,the following"IN PERSON" public hearing will be held by the SOUTHOLD TOWN ZONING BOARD OF APPEALS at the Town Hall, 53095 Main Road, Southold, New York 11971-0959, on THURSDAY, OCTOBER 5, 2023: The public may ALSO have access to view,listen and make comment during the PUBLIC HEARING as it is happening via ZOOM WEBINAR. Details about how to tune in and make comments during the PUBLIC HEARING are on the Town's website agenda for this meeting which may be viewed at http://southoldtownny.gov/agendacenter. Additionally,there will be a link to the Zoom Webinar meeting at http://southoldtownny.gov/calendar.aspx. 10:00 A.M.-WALTER GLESS#7826-Request for Variances from Article XXIII, Section 280-124; and the Building Inspector's June 28, 2023 Notice of Disapproval based on an application for a permit to legalize the"as built" demolition of an existing residence (as per Town Code definition) and to reconstruct a single family dwelling;at 1) less than the code required minimum rear yard setback of 35 feet; located at 800 Koke Drive, (adj. to Corey Creek)Southold, NY.SCTM No. 1000-87-5-7. 10:10 A.M.—QJSG PROPERTIES, LLC#7827-Request for Variances from Article III,Section 280-13C; Article III,Section 280-15;Article XXII, Section 280-105D(4); and the Building Inspector's May 9, 2023,Amended July 28, 2023 Notice of Disapproval based on an application for a permit to install additional deer fencing and to construct an accessory potting shed, a chicken run with coop, a goat barn,an accessory artist studio structure, barn, and two (2) hoop houses,and to legalize an "as built"accessory pergola, a greenhouse and two (2)sheds on rural residential property; at 1) the proposed artist studio use in the accessory building is not a permitted accessory use; 2)seven (7) proposed accessory structures located in other than the code permitted rear yard; 3)four(4) "as built" accessory structures located in other than the code permitted rear yard;4)deer fencing located in the non-permitted front yard or primary front yard jocated at: 38015 NYS Route 25,Orient, NY.SCTM No. 1000-15-2-15.7. 10:20 A.M.-JOSEPH C. MCCORMACK,JR.#7828.- Request for Variances from Article XXIII,Section 280- 124, and the Building Inspector's June ' 28, 2023 Notice of Disapproval based on an application for a permit to demolish (as per Town Code definition) and reconstruct a single family SOUTHOLD TOWN BD OF APPLS 2 f908b203-bd63-423e-a024-2db22f103ecd Idmf@southoldtownny•gov AFFIDAVIT OF PUBLICATION The Suffolk Times dwelling; at 1) less than the code required minimum primary front yard setback of 35 feet;2) less than the code required minimum rear yard setback of 35 feet; located at: 2670 Stillwater Avenue, Cutchogue, NY.SCTM No. 1000-136-2-17.1. 10:30 A.M. - PATRICK MCELROY#7830-Request for Variances from Article XXIII,Section 280-124; Article XXXVI,Section 280-207A(1)(b);and the Building Inspector's May 25, 2023 Notice of Disapproval based on an application for a permit to demolish (as per Town Code definition) and reconstruct a single family dwelling; at 1)located less than the code required minimum primary front yard setback of 35 feet;2) located less than the code required minimum side yard setback of 10 feet; 3) more than the code permitted maximum lot coverage of 20%;4)gross floor area exceeding permitted maximum square footage for lot containing up to 20,000 square fW�in/2rea; located at:440 Third Street, New Suffolk, NY. SCTM No. 1000-117-9-20. (((JJJ 10:40 A.M.- MICHAEL AND NICHOLAS GIACONE#7829-Request for a Variance from Article XXIII, Section 280-123, and the Building Inspector's May 3,2023 Notice of Disapproval based on an application for a permit to legalize "as built"front porch and rear deck attached to an existing seasonal dwelling; at 1) a nonconforming building containing a nonconforming use shall not be enlarged, reconstructed,structurally altered or moved, unless such building is changed to a conforming use; located at: 270 Park Avenue Ext., (Adj. to Deep Hole Creek) Mattituck, NY.SCTM No. 1000-123-8-27. 10:50 A.M.-TRACY AND ALEXANDER SUTTON #7831-Request for a Variance from Article III,Section 280-14 and the Building Inspector's June 28,2023 Notice of Disapproval based on an application for a permit to legalize "as built" alterations to convert to habitable space in the attic (third floor) of a single family dwelling, and to rescind a condition of a permitted Special Exception; at 1) as per condition#4 stipulated in Special Exception file#7527SE,dated September 16, 2021 which states the third floor attic shall not be used as living space by owner nor by the Bed and Breakfast guests and is to remain unheated and unconditioned for storage use,only; located at 25500 Main Road,Orient, NY.SCTM No. 1000-18- 6-10. 11:00 A.M. - ROBERT S. MARTIN#7833- Request for a Variance from Article III,Section 280-15,and the Building Inspector's May 23, 2023 Notice of Disapproval based on an application for a permit to construct an accessory pool pavilion; at 1) located in other than the code permitted rear yard; located at: 1600 Little Neck Road,Cutchogue, NY. SCTM No. 1000-103-4-13. 11:10 A.M.- KATHLEEN WALAS,AND THOMAS SARAKATSANNIS#7835-Request Variances from Article XXIII,Section 280-124;Article XXXVI, Section 280-208A, and the Building Inspector's May 25, 2023, Amended July 7, 2023 Notice of Disapproval based on an application for a permit to demolish (as per Town Code definition) and reconstruct a single family dwelling with swimming pool addition; at 1) located less than the code required minimum front yard property line setback of 40 feet;2) located less than the code required minimum side yard property line setback of SOUTHOLD TOWN BD OF APPLS 3 f908b203-bd63-423e-a 024-2db22f103ecd kimf@southoIdtownny.gov AFFIDAVIT OF PUBLICATION The Suffolk Times . 15 feet; 3) the construction exceeds the permitted sky plane as defined in Article XXXVI,Section 280-4 of the Town Code; located at:750 Brooks % Road (adj.to Pipes Neck Creek,Greenport, NY.SCTM No. 1000-53-1-16. 1:00 P.M.-CHARLES DISAPIO AND XANNE PEREZ#7832-Request for a Variance from Article III,Section 280-13C, and the Building Inspector's July 13, 2023 Notice of Disapproval based on an application for a permit to legalize an "as-built" artist studio with a half bathroom in an existing accessory garage; at 1)the proposed use in the accessory building is not a permitted accessory use; located at:5780 New Suffolk Avenue, (adj. to Deep Hole Creek) Mattituck, NY.SCTM No. 1000-115-10-7. 1:10 P.M.—EDWIN J. PISANI#7834SE-Applicant requests a Special Exception under Article III,Section 280-13C(13). The Applicant is owner of the subject property requesting authorization to establish an Accessory Apartment in an existing accessory structure;at:7180 Peconic Bay Boulevard, (adj.to Great Peconic Bay) Laurel, NY,SCTM#1000-126-11-9.1. 1:20 P.M.—WILLIAM AND STACEY BRENNEN#7837-Request for Variances from Article XXIII,Section 280-124;Article XXXVI,and the Building Inspector's July 24,2023 Notice of Disapproval based on an application for a permit to construct additions and alterations to an existing single family dwelling; at 1) located less than the code required minimum side yard setback of 15 feet; 2) located less than the code required minimum combined side yard setback of 25 feet; located at: 1050 Trumans Path (Adj.to Marion Lake), East Marion, NY. SCTM No. 1000-31-12-5.1. 1:30 P.M.—NORTH FORK PROJECT 2, LLC. & NORTH FORK PROJECT 3, LLC.#7836- Request for Variances from Article III,Section 280-14 and Article III, Section 280-15;and the Building Inspector's June 20,2023 Notice of Disapproval based on an application to create a two lot subdivision; at 1) proposed Lot 1 is less the code required minimum lot size of 80,000 square feet; 2) proposed Lot 1 is less than the required lot depth of 250 feet; 3)a Greenhouse located on proposed Lot 2 is less than the minimum required side yard setback of 20 feet; located at 10020 Sound Avenue and 9650 Sound Avenue, Mattituck, NY. SCTM No. 1000-122-2-8.1 and 1000-122-2-24.4. 1:40 P.M.-CHRIS AND MARISA LAZOS#7809—(Adj.from Sept.7, 2023) Request for Variances from Article IV,Section 280-18;Article XXIII, Section 280-124;Article XXXVI, Section 280-207A(1)(b);and the Building Inspector's March 10, 2023 Notice of Disapproval based on an application for a permit to construct additions and alterations to an existing single family dwelling; at 1) exceeding the maximum permitted two and one half(2 1/2)stories; 2)gross floor area exceeding permitted maximum sq.footage for lot containing up to 20,000 square feet(buildable)in area;3) more than the code permitted maximum lot coverage of 20%; located at: 1200 Leeton Drive, Southold, NY.SCTM No.59-1-1. 2:00 P.M.- BUDD'S POND MARINA, INC.,AKA ALBERTSONS MARINA, WIRELESS CELL TOWER#7839: Request for Variances from Article XIII, Section 280-53; and the Building Inspector's August 9, 2023, Notice of Disapproval based on an application for a permit to construct a new SOUTHOLD TOWN BD OF APPLS 4 f908b203-bd63-423e-a024-2db22f103ecd kimf@southoldtownny.gov AFFIDAVIT OF PUBLICATION The Suffolk Times wireless telecommunications facility; 1) having less than 160,000 sq.ft. as required for a second principal use (80,000 sq.ft. per principal use) in Mil Zoning District where a principal use as a marina with boat storage already exists; 2) located less than the code required minimum rear yard property line setback of 25 feet; 3)more than the code permitted maximum lot coverage of 30%; located at: 61405 Main Road,Southold, NY. SCTM#1000-56-3-15. The Board of Appeals will hear all persons or their representatives, desiring to be heard at each hearing, and/or desiring to submit written statements before the conclusion of each hearing. Each hearing will not start earlier than designated above. Files are available for review on The Town's Weblink/Laserfiche under Zoning Board of Appeals(ZBA)\Board Actions\Pending. Click Link: http://24.38.28.228:2040/weblinl</Browse.aspx?dbid=0. If you have questions, please telephone our office at(631)765-1809, or by email: kimf@southoldtownny.gov. Dated: September 21, 2023 ZONING BOARD OF APPEALS LESLIE KANES WEISMAN, CHAIRPERSON By: Kim E. Fuentes 54375 Main Road (Office Location) P.O. Box 1179,Southold, NY 11971-0959 SOUTHOLD TOWN BD OF APPLS 5 i f908b203-bd63-423e-a 024-2db22f103ecd kimf@southoldtownny.gov AFFIDAVIT OF PUBLICATION The Suffolk Times State of New York, County of,Suffolk, The undersigned is the authorized designee of The Suffolk Times,a Weekly Newspaper published in Suffolk County, New York. I certify that the public notice, a printed copy of which is attached hereto, was printed and published in this newspaper on the following dates: September 28,2023 This newspaper has been designated by the County Clerk of Suffolk County,as a newspaper of record in this county, and as such, is eligible to publish such notices. Signature Christina Henke Rea Printed Name Subscribed and sworn to before me, This 29 day of September 2023 Ota y Sign Ure S rrnn',,'°o•,, S1 KI E 'OF NEW YORK . NOTARY PUBLIC C \LBANl r 11iRIktVti;-at Notary Public Stamp '°�,�'l��s; ���Z 'e''rrrraaaaaea�aj1j1°1�° SOUTHOLD TOWN BD OF APPLS 1' BOARD MEMBERS Southold Town Hall-- Leslie Kanes Weisman,Chairperson ��if soyo53095 Main Road-P.O. Box 1179 Patricia Acampora 1p Southold,NY 11971-0959 Eric Dantes [ Office Location: Robert Lehnert,Jr. G Town Annex/First Floor Nicholas Planamento 54375 Main Road(at Youngs Avenue) °lycougm Southold,NY 11971 http://southoldtownny.gov ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631) 765-1809 LEGAL NOTICE SOUTHOLD TOWN ZONING BOARD OF APPEALS THURSDAY, OCTOBER 5, 2023 at 10:00 AM PUBLIC HEARINGS NOTICE IS HEREBY GIVEN, pursuant to Section 267 of the Town Law and Town Code Chapter 280 (Zoning), Town of Southold, the following public hearing will be held by the SOUTHOLD TOWN ZONING BOARD OF APPEALS at the Town Hall, 53095 Main Road, Southold, New York 11971-0959,-on THURSDAY, OCTOBER 5, 2023: 2:00 P.M. - BUDD'S POND MARINA, INC., AKA ALBERTS0148 MARINA, WIRELESS CELL TOWER #7839: Request for Variances from Article XIII, Section 280-53; and the Building Inspector's August 9, 2023, Notice of Disapproval based on an application for a permit to construct a new wireless telecommunications facility; 1) having less than 160,000 sq. ft. as required for a second principal use (80,000 sq. ft. per principal use) in MII Zoning District where a principal use as a marina with boat storage already exists; 2) located less than the code required minimum rear yard property line setback of 25 feet; 3) more than the code permitted maximum lot coverage of 30%; located at: 61405 Main Road, Southold, NY. SCTM#1000-56-3-15. The Board of Appeals will hear all persons or their representatives, desiring to be heard at each hearing, and/or desiring to submit written statements before the conclusion of each hearing. Each hearing will not start earlier than designated above. Files are available for review on The Town's Weblink/Laserfiche under Zoning Board of Appeals(ZBA)\Board Actions\Pending. Link: http://24.38.28.228:2040/webiink/Browse.aspx?dbid=0. If you have questions, please telephone our office at(631)765-1809, or by email: kim f@southoldtownny.gov. Dated: September 21, 2023 ZONING BOARD OF APPEALS LESLIE KANES WEISMAN, CHAIRPERSON By: Kim E. Fuentes 54375 Main Road (Office Location) 53095 0-Min Road (Mailing/USPS) P.O. Box 1179 Southold, NY 11971-0959 Town Hall Annex, 54375 NYS Route 25 P.O.Box 1179 y w �r . Southold, New York 11971-0959 Fax(631) 765-9064 l / ZONING BOARD OF APPEALS DATE: September 5, 2023 I RE: INSTRUCTIONS FOR PUBLIC HEARING Dear Applicant; Pursuant to the New York State Governor's announcement lifting many COVID-19 restrictions, the Town will now resume IN-PERSON meetings that are open to the public. For those who wish to attend the meeting virtually, for health and safety reasons, we will continue via Zoom Webinar, as well. Therefore, the October 5, 2023 Zoning Board of Appeals Regular Meeting will be held BOTH in person in the Town Hall Meeting Room at 53095 Main Road, Southold AND via video conferencing (Zoom Webinar), and a transcript will be provided at a later date. The public will have an opportunity to see and hear the meeting live, and make comments. Below;�please;see, i tructions,required to rey,�are>for;the.ZBA ublic hearing which.includes: r `A e'-- ,. 1? 'PL`EASE R AD`CARE`FITLLY: 1. Yellow sign to post on your property a minimum of seven(7) days prior to your hearing, to be placed not more than 10 feet from the front property line (within your property) bordering the street. If you border more than one street or roadway, an extra sign is supplied for posting on both street frontages. Posting should be clone no later than September 28, 2023. To avoid weather damage to your sign please affix it to a sturdy surface such as plywood. If your sign is damaged please call the office and we will provide you with another one. Prior to your public hearing, members of the Board of Appeals will each conduct a personal inspection of your property.If a Board member reports that there is no signage visibly on display as required by law,your scheduled hearing will be adjourned to a later date to ensure compliance with Chapter 55-1 (B) 1 of the Town Code. 2. SC Tax Map with property numbers. 3. Legal Notice of in person-meeting,as well as video conferencing. Instructions for participation will follow, and will be posted on the Town's Website under the meeting date, and the Legal Notice section of Suffolk Times Newspaper. 4. Affidavits of Mailings and Posting to be completed by you, notarized, and returned to our office along with the mailing receipts and green cards by September 28, 2023, verifying that you have properly mailed and posted. Please attach a photograph of the posting on your Property with your affidavit of posting. 5. Instructions for Laserfiche/Weblink to view application. Instructions for ZBA Public Hearing �1 Page 2 MAILING INSTRUCTIONS: Please send by USM Certified Mail, Return Rec ie pt the following documents to all owners of property (tax map with property numbers enclosed) vacant or improved, which abuts and any property which is across from any public or private street. We ask that you send your mailings promptly so that if any piece is undeliverable, you can reach out to your neighbors to request their mailing addresses, and re-mail. Mailing to be done by September 18,2023. a. Legal Notice informing interested parties of meeting being conducted IN PERSON and via video conferencing. (Enclosed) A WEBLINK to the meeting will be provided on the Town's Website under the date of the meeting. b. Your Cover Letter which should include your contact information, date and-time of hearing, procedures for submitting written comment via email or USPS to our office. Recipients should be able to contact you for additional information. Furthermore, if recipients need to contact the ZBA staff,they may telephone 631-765-1809 or email us at kimf@southoldtownny.gov or elizabeth.sakarellos(a)town.southold.n y�us c. Instructions for Laserfiche/Weblink to view all pending applications. (Enclosed) Link to view pending applications: http://24.38.28.228:2040/weblink/Browse.aspx?dbid=0. d. Surveyor Site Plan depicting "as-built" and proposed improvements requiring ZBA relief. The Town's Laserfiche/Weblink files provides both location addresses and mailing addresses in their current Assessment Roll listing. (See Link Below). Also, the Town Assessor's Office can be reached at 631-765-1937. Contact us via email or by phone if you need further assistance. TownOfSouthold>Assessors>Assessment Books/Tax Rolls https:Hsoutholdtownny.gov/DocumentCenter/View/9694/TentativeRo112023 iIMPORTANT,;hNST.RUCTIONS:,. ..=" _ �.y, d Scan mnd,ema!F the iTSPS..ma mg receipts green t sign1atuare'car� sh$and affidavits to '+f' i .'h.' � '�' n ...'v s' r j, - -,�.,� " � 'Y`r.�...'c ,7,dzi.�si#Cx 4.� ��^F k;i'�• �± .�r - : kiinf(a7soutl oldto_wnny:gov,sand * aPROMPTLY`IThS�PS MAIL the OR,-1rGINAUS to tlieTow'n afSoutholdZ A P: Laserfiche Instructions for Zoning Board of Appeals Records € rOF $ © SOUTHOLD poiNSrar.r 4 averamen ' zvices isitfi:s Host C}a I... Fn J N i, •,: TO Tt.P Aln I �.'}'+'`?'?t,'",:.;�s( iY;� /fir ':t,if"::;:<(,.'::1 '�,-4y �'.u. .?' `"sK,;• `3 ,i.`.'..(,�'yJ I�. '+;'jk'r� ..�� - .,.'�` #.,,,..,,� :r.it,. ..:iiiib ,��f� a� ::r�;,: �., ,-J• i /a," hrw' {.','','Y,a. 'S:. ....sem i.'•'s"fb« .'>": ,�, .rS tIa`5fi�.:-t:��''='7'O4otY1'•OdC .4lEtIIIltP• �uaiiosa`:; ��.•._ `r' �biils•;--' zteti!iitk.'ias+;r5stie'4 .Fpii:til�p�l ;5iysicg'.zo+;etai,*'C.• s;t�, � � .�; .:i. '7s'� 't;,'. :".;, � ..: ...✓a. �''y�`�'.�' ..'r'f`',_..+...'.aL..�..r.....•��«:..�.u}....�"rif101i2tC%A:.i«::K'.la4,..G w.....r-.,.«....�.a.�.:si..v.....ur:L�:d✓.. ad....._.......wv...::�+«.:�Y:.:.v4ifhTrlfD2#Iftii,:..f:.•.�+s'.�.� ...':✓.+:�.::v:.C.^1tawliw.}F:�u«.i'c. Above: Homepage, Click on Link"Town Records"Weblink/Laserfiche Laserfithe VietiLink • ^rti.veaUnk ,-ego:o�ont van est Nome Browse Searco TownCdSourho#d TownOfSouthold Name Pagamunt µTown Clerk EntryProperties rown:�rstorian Path Trustees Tz,�,:�OtSrwt#wt! BoaN of appeals ZBA) ...,d Zoning ._ .. - Creation dace _;5,2014 1'!52.4'>:M Page 2 of Z F;r54 a 29 Entries Last modified " A Metadata . •.o n•_.a iau assgE d ' Above: -The second of two pages you will find "Zoning Board of Appeals (ZBA)" in the list of Town of Southold Departments. Click the Zoning Board of Appeals(ZBA)folder/link. G\Laserfiche Instructions ' ZBA Files " Page 2 Laserliche WehLink _ +� bN•rr"auu:HNP ACc><: stgr,a,c Home Browse Search IownOf$outtfolrl>Zomn8 Board of appeals QBA) Zoning Board of Appeals Name Page count ;icrtip"name , (ZBA) Alpnahetical Index e Entry Properties - - _.Board Actions ea LaserFiche Search Guides Path a Meetng Schedules -owrtiva�iMld[Zeni:lg Bc�r of Appeals(ZBA) Minut"Agendasaegal Noticesmearings Creation date j„-I Pending "7l10R^Ot 72:'f.!r.Pt.. �1 Reports Last modified dal Event Permits 5.23:2077,::07:FG Ata C.1 Special . ;y Training Requirements ZBA Dfficia:5 A Metadata ZBA Polldes ::")0:neladata nsv led .�Exceotlons Ust Code 280.1Ce(3) j Jurisdiction Listing 1 1�ZBA Book of Mapped 1977 Existing Lots 199 &Res =m1hmM7WP. �� Bulk Schedules n 5 Agreements,Contracts&Leases ymin ,tJ Page 1 of 1 .a entries Above: Listed are types of records under ZBA Folder. ZBA Decisions can be found under Board Actions. Click on 'Board Actions"folder to open. Laserliche WehLink ,O '� M,'+`bL;r11 1-eP Abut Si3,10-t Home Browse Search To.vnCr50uNh5]>Zoning 50,rd of Appeals KSA7>Board Actions Board Actions Name Page count Template rwme 1957-1979 2 Entry Properties ^i'980-1995 Path 2000 TownOr50ut:ro![,^•Z:vu:,�,ec._rd .:�T.):p7reh EA;\Bc»r•7MCnns 2001 Creation date 2002 2003 Last modified 2004 3r28RCi7 1136:07?3.4 2005 R Metadata -^.2005 2007 dSV7,ed 2008 :009 ___......._.............� (2010 &R>ults srtNpaP�smeu=UsrR 2011 j 2012 2013 2014 j 2015 u 2016 y 2027 r`^Pending re.heaKNv;tcomrf.<aah P+P'smm+Uxr1 Dom,,.,t„r s �.__._.__ Above: Board Actions are listed by year. Click folder to open. All Special Exception applications that require Coordinated SEQRA Analysis are stored in "Pending". l Laserfiche Instructions ZBA Files Page 3 "i", .—se Sea'. 1111do!`a-dO.M'As lao911 U"—•20,1 2017 as a683 Erl"—Jas le A,o— Path 93 Board-1 .—d nNans O.W.Will Fort• 's ed,ra norms mdenm —d-.,x v rots a] BoaN,mdre H3 edam xndv No wlo,1 7017 7o —ol-.o, ons sa ll—d— 'Onq so 0—d— 70:9 so .—"o— tiv 59 Board Mons 7025 ]5 80.n!A.— nn 335 ao.ni_oo 7624 ro9s 518 a—d ;.26 ;3 7W W Hoard —d -9 a Go- Above: See listed File Numbers. Click on file you are searching. cashel Above: In addition searching by file no. You can also use the above search tool by typing the name or title of the applicant. Laserfiche WebLink C.'el 41 Home Browse Search clqo—e SaIrch Sort results by: Relevance v Records MapaiIan,ert 5-- 7016 And— Board Actions-33 cages) Ch...feed Page count:83 Template name:Board Actions Reset Daga 3 Colin and Kristen Cashel PROPERTY LOCATION:162 Lower Shingle H01,F'sner Page 19.2017.:016.Cashel SRM No.1000-9-1-26 mrimus approval to reMO-.- age 5...y 19.2017 97016,Cashel SRM No.1000-9-1-26 GRANT.the variances as Search;erns Page 9 COLIN&KRI5TEN CASHEL SECTION 009 BLOC ci_ Thomas Ahlgren(Cashel).PO Box 342 Fishers island.NY.. Show more information... 7018 Board Actions-56 pages! Page count:56 Template name;Board Actions P+9-All 9.30 A.M.-COLiN C SRFI AND Varlanroc-dn,A-10 ld.S—on ANN... cage 48 ance(s)KRISTEN CASHEI-97016 Ratuest proposed trellis located in other cria - Show more information Above: Shows you files that can be found using a phrase, name or title. Or you can search by Tax Map No. (District, Block and Lot) using the format 1000-Ill.-I-1. d Laserfiche Instructions ZBA Files Page 4 11 Laserflche WebLink nor«nine: Ip nnu 1• s Home Browse Search Twinwsouthoid>Zoning Board of ARLeaIS(ZBA)>h1inutes/A.<gendasrLegal Notices/Hearings Minutes/Agendas/Legal Name page count Notices/Hearings I 021957-1979 Entry Properties .7 1960-IM ......... .___.._-._._ .. ;a 20002009 path Towr.OfSoutnold.Zonntg Board +r++2010 u Appeals t2 2011 IZBA) 1Ynu: -r;Sgendas:.C$3t Nome'll leanngq Creation date r 20.3 7/;,W20,01 257:40 PRM 'I 2014 Last modified -n 20.5 12.11EW--I S_'5::4'IV. 20:6 z bletadata :y,20:7 No metadata a-z gned Page 1 of 1 11 Ent, :seev.✓a.e*Kr..i—vN>eeaw+chf+-�.�:v'x.p...��r,lt<F.::l}L�CL'Y..ym K....a Above:Also, Minutes,Agendas, and Hearing Transcripts can be viewed. Laserfiche WebLink MyWebunl, llelp I About Home Browse search TownCfSouthold>Zoning Board of Appeals(ZBA)>Minutes/Agendas/Legal NOtiCCS Heanngs>2017 2017 Name Page count Template name Z3401 105/2017 entryProperties ZBA-01!05/2017 Agenda 4 Path Z3A-01;051201--learing 40 r;wnof5oucrorolZOninz_Board Of Appeals •�ZBA-0i,'05/2011 LN 3 ;ZBA I+Minutes A3en0aS;Legal •ZBA-0111912017 2 t+onCevFlearmgs'•2o1; -' .� ZBA-01 119/2017 Agenda - Creation date 1 2/16/201 6 2:15,'4 VM ZBA-02/0212017 7 Last modified -i ZBA-0210212017 Agenda 4 6!19!'.0174:5,:50P'4 d ZBA-02/02!2017 Hearing 45 2 Metadata _j Z3.4-02102!2017 LN 3 73A-0711612017 Agenda 3 N0 rnetaddld ds5,gnEY1 �-:ZBA-02116:2017 Spec-al 3 , _edure a<Results a,ZBA-03/0212017 7 .m/nedthJpap=smeaRUses2 ,�ZBA-03/022017 Agenda 4 ---_ -- G ZBA-03102/2017 Hearing 65 ZBA-0310212017 LN 3 ZBA 03/16/2017 Agenda 3 G'ZBA-031162017 Special 3 j ZBA-041062017 5 y ZBA-041062017 Agenda 4 Z3A-06;06;2017,Hearing 45 Above: Agendas, Minutes and Transcripts are in chronological order. 4uT1 (., �- - ' F AR1140 The following application will be heard by the Southold Town Board of Appeals at Town Hall, 53095 Main Road, Southold: The application will also be available VIA ZOOM WEBINAR= Follow Iinkmhttp://southoldtownny.gov/caIendar NAME : BUDD'S POND MARI NA/ALBERTSON MARINE #7839 SCTM #00 1000-56-3- 13 'i 'ARIANCE: 2ND PRINCIPAL USE ON PROPERTY, SETBACK 8 LOT COVERAGE VIEQUESTm CONSTRUCT A NEW WIRELESS TELECOMMUNICATIONS FACILITY SATE : THURS . OCT 51 2023 2 :00 PM You may review the file(s) on the town's website under Town RecordslWeblink: ZBAIBoard ctions/Pending. ZBA Office Telephone (631 ) 765-1809 ryA LYNCH APPRAISAL LTD. �J REAL ESTATE APPRAISERS AND CONSULTANTS 15 DEWEY STREET HUNTINGTON,NEW YORK 11743 (631)427-1000 September 26, 2023 Town of Southold Town Hall 54375 Main Road Southold, New York 11971 Re: Real Estate Consulting Report RECEIVED Elite Towers, LP, New York OCT 52023 SMSA Limited Partnership d/b/a Verizon Wireless, DISH Wireless, ®NING�QARD�F�, LLC, & Southold Fire District Proposed Communications Facility: Concealment Pole Located at Albertson Marine (Boatyard 7955 nRal Rea &j qC? Dear Board Members: cSc7 o In accordance with a request from the applicants, Elite Towers, LP, New York SMSA Limited Partnership d/b/a Verizon Wireless, DISH Wireless, LLC and Southold Fire District, collectively hereinafter referred to as the "Applicants" , I have inspected the above site and prepared a Real Estate Consulting Report (the "Report" ) regarding potential effects of a proposed wireless communications facility (the "Communications Facility" ) on the surrounding community. After considering the location, market conditions, proposed build, and all other factors that influence value, it is my professional opinion that the Applicants' proposed Communications Facility will not negatively affect property values in the surrounding area and will not have any adverse effect on the character of the neighborhood or the pattern of its development, and is compatible with the site and surrounding structures and uses. My conclusions are outlined in the following Report. Respectfully submitted, LYNCH APPRAISAL LTD. By: Michael J. Lynch N.Y.S. Cert. General R.E. Appraiser #46000001012 r l 2 Purpose and Intended Use of Report The purpose and intended use of the Report is to study any possible adverse effects the proposed Communications Facility will have on the surrounding community. This Report is strictly prepared at the request of the Applicants to present to the Town of Southold Zoning Board of Appeals for a hearing to be held on October 5, 2023. Effective Date of Report The effective date of the Report is September 26, 2023, the date of inspection of the Property by Mr. Michael J. Lynch. Description of Proposed Communications Facility The Applicants ' proposed Communications Facility consists of, without limitation, the installation of whip antennas (at a top height of 164 '10" AGL) by the Southold Fire District atop a 150 ' AGL RF-transparent concealment pole (the "Concealment Pole" ) , plus six ( 6 ) panel antennas by Verizon Wireless and three ( 3) panel antennas by DISH Wireless concealed within said tower structure. The Communications Facility will be situated at the northerly boundary of "Albertson Marine, " a boatyard (the "Property" ) that backs to a Long Island Railroad ( "LIRR" ) right-of-way. In addition, associated equipment cabinetry will be mounted on a steel platform within a 70 ' x 35 ' fenced (chain link) compound (the "Compound" ) , which will also surround the Concealment Pole, with the Compound being landscaped with staggered 6100 tall arborvitae plantings. Moreover, the Concealment Pole and Compound will be designed to accommodate future carriers. Lastly, the Concealment Pole and Compound will be located behind (to the north) of an existing and large marine storage building, and immediately adjacent to the south side of the noted and somewhat elevated LIRR r/o/w, thereby screening said Compound from Main Road and the nearest residences. 3 Description of Property and Surrounding Neighborhood The Property consists of a 0.95± acre parcel located along the northerly side of Main Road (S.R. 25 ) and southerly side of the LIRR, distant 19571± easterly of Laurel Avenue, in the Hamlet of Southold, Town of Southold, Suffolk County, New York. It is also known and designated by Suffolk County Tax Map Number: District 1000, Section 56, Block 3, Lot 15, and is situated within a Town of Southold Marine (II ) Zoning District. The Property is generally level and improved with a marine storage building plus associated paving for driveways, parking and outdoor storage areas. It is in use as a boatyard with related repair and storage of marine vessels and boat trailers. The Property is abutted on its east and west by parcels associated with Albertson Marine, which includes offices, boat sales and marine supplies, and additional boat storage. Diagonally opposite to the southeast, along the south side of Main Road and fronting on Budd's Pond, is the Albertson Marina, with associated boat slips, loading ramp and other marine related services. Directly south from the Property, along Main Road, is County-owned open space wooded land and wetlands. Opposite the Property, along the north side of the LIRR, is a Town-owned partially-wooded land preserve. Other nearby uses along Main Road include a motel, Port of Egypt Marina, and a shuttered restaurant. The nearest residences are to the west-southwest on Budd's Pond Road, some of which back to Main Road, and to the west-northwest on Pond Avenue, with a residence that backs to the LIRR tracks and is the closest residential structure to the proposed Communications Facility, being approximately 555 feet away. 4 Scope of the Report In preparing this Report, the appraiser: - Inspected the Property and surrounding community on September 26, 2023; - Reviewed the Verizon Wireless and Southold Fire District engineering drawings prepared by Jeremy K. McKean, PE, dated 8/30/23, and DISH Wireless engineering drawings by Jeremy K. McKean, PE, dated 8/31/23; - Reviewed Suffolk County and Town of Southold assessment, tax map and zoning records; - Researched sales trends in the area of the Property in addition to comparable sites throughout Suffolk and Nassau Counties, including the North Fork and East End; and - Prepared this Report. Report Methodology In analyzing any potential adverse effect the Communications Facility may have on the surrounding community, the appraiser considered the proposed build of the Communications Facility on a commercial boatyard, located along a major east-west artery of the North Fork artery, and adjacent to an LIRR right-of-way. in addition, we have reviewed and carried out studies with respect to wireless communications facilities in Nassau and Suffolk Counties. These communications facilities include stealth flagpole and monopole sites, lattice and guyed wire tower sites, rooftop mounted sites, and water tank sites. On the following pages are two studies that include a stealth monopole site at the beginning of the North Fork, and a monopole site in the Village of Southampton. i 5 x-,9 1) 130' Stealth Wireless Monopole(Flagpole)at Cherry Creek Golf Links,900 Reeves Avenue, Centerville(Riverhead) A 1301± stealth monopole was erected at this golf course in 2003 (see Figure 3 ) . Subsequent to the monopole, a new development of single-family residences commenced adjoining the golf course and said wireless facility to its east. This homeowner's association, known as the "Highlands at Reeves, " had its first sale in 2006. The development includes a community pool, clubhouse, and other amenities typical to a modern homeowner's association development on Long Island. The golf course and development are built on former agricultural lands. Our staff looked at sales data within the Highlands at Reeves from 2006-2014, finding 36 sales ranging from $399,000-$850, 000, or on a per square foot of building area running from $136/SF-$258/SF. The average and median sale price per square foot was $197/SF and $199/SF, respectively. We then compared this above data to a very similar development located 1 .5± miles to the east known as "The Highlands at Aquebogue, " situated along the south side of Sound Avenue, adjacent to the east side of the Long Island National Golf Club. The Highlands at Aquebogue had its first sale in 2006, with units still available as of 2014 . Our researched sales run from 2006-2014, revealing 65 sales ranging from $425,000-$719 ,000, or on a per square foot of building area running from $135/SF-$252/SF. The average and median sale price per square foot was $201/SF and $207/SF, respectively. The difference between the two groups, utilizing average and median sale prices per square foot of building area, was very close, differing by a nominal 20-4%. Therefore, based upon these two groups of data, it does not appear that the presence of the 130 ' monopole had an appreciable effect on the adjacent residential community. 6 ��'s.;r,�`�•,.+ Monopole � r, � k .ti. ► ` a L ` .. .�'�" .,� .aria '� � • �, A VP Lr- Figure 1: Birdseye View of Cherry Creek Golf Links with Mono 0 nd Adjacent Development C)C) 1 I j 2) 165' Monopole at 145 Powell Avenue.Village of Southampton A 165 ' monopole with exposed antennas at the above address was constructed and received a certificate of occupancy from the Village of Southampton on April 15, 2016. The structure sits on an industrial- zoned improved parcel and is adjacent to an L.I.R.R. right-of-way. The Suffolk County Tax Map of the parcel is 0904/9/2/22.2. Opposite this monopole, along the south side of Powell Avenue, the neighborhood is 100% residential and consists of streets comprised of a mix of older and newer 1-family dwellings on lot sizes ranging from roughly from 1/3 to 1 acre in land area. Due to the high demand for building sites in the Village, many of the older, modest homes are being razed to make way for new, luxury-market priced residences. In addition, many of the dated but larger dwellings are being renovated or rebuilt and selling for luxury market prices. The rebuilt or newer residences in the neighborhood are typically selling in the $2 ,000,000 to $3,500,000 range, and almost all contain in-ground swimming pools as an amenity. In this study, I focused on renovated or newer luxury-priced home sales along Pulaski Street, 1 block south of Powell Avenue, that generally possesses visibility of portions of the monopole due to the 165 ' height of the communications facility and the area's level topography, but do not face industrial or commercial properties. The Pulaski Street sales were then compared with a similar mix of home sales farther south in the same neighborhood and Tax Map Section where the monopole visibility becomes greatly decreased. The average and median closing dates in each sample is close, both differing by less than two months. The two sets of data, on a price per square foot of gross living area (GLA) , are compared below: Based on the below data of closed luxury-priced home sales, the closer proximity and general visibility of portions of the 165 ' monopole did not appear to lead to lower real property values of properties along Pulaski Street when compared to that of properties along streets farther south with greatly reduced visibility of said structure. Home Sales Alone Pulaski Street Home Sales on Streets Near 165'Monopole Date of Sale WIF of GLA Farther South of 165'Monopole Date of Sale SF of GLA 70 Pulaski Street,Southampton 6/23/21 987 152 Pelletreau Street,Southampton 11/16/20 1178 79 Pulaski Street,Southampton 4/1/21 1239 24 Osborne Avenue, Southampton 11/2/20 1039 64 Pulaski Street,Southampton 3/20/21 943 175 Wooley Street,Southampton 10/15/20 892 24 Pulaski Street,Southampton 6/3/20 969 97 Pelletreau Street,Southampton 8/6/20 894 154 Pulaski Street,Southampton 8/7/19 831 148 Wooley Street,Southampton 6/18/20 1078 44 Pulaski Street,Southampton 4/19/17 814 174 Wooley Street,Southampton 9/13/19 827 32 N.Wooley St.(cor.Pulaski St.)South. 3/9/17 1107 75 Halsey Avenue,Southampton 8/20/18 928 21 Van Brunt Street,Southampton 4/28/18 922 Mean$/SF 984 Mean$/SF 970 Median$/SF 969 Median$/SF 930 «► 1 9 yJ _ r,gure 3: View of 165' Monopole at Powell Ave., Southampton (C.O. 4/15/16) ti Figure 4: Visibility of Monopole Viewed Between Two Residences on Pulaski Street, Southampton 10 �l Conclusions V In summary, we offer the following conclusions: - The proposed Communications Facility is appropriate for the Property given that the application involves the mounting of panel antennas within a Concealment Pole, with the affixing of a fire department whip antenna atop said structure, on a commercial-zoned boatyard. In addition, the Concealment Pole and landscaped Compound with associated ground equipment will be located behind (to north) of an existing steel frame marine storage building, adjacent to a slightly elevated LIRR right-of-way, thereby screening said Compound from Main Road and nearby residences. - The proposed Communications Facility is designed to accommodate additional wireless carriers in the future, thereby eliminating the need for further wireless structures in the immediate neighborhood of Mattituck. - The Property, with its primary boatyard use, is well suited for the Communications Facility considering other factors and existing conditions that include proximity to an LIRR right-of-way and adjacent commercial and marine uses. In addition, the Property's immediate proximity to County- and Town-owned wooded preserve land will help to screen the Communications Facility from the nearest residential structures to the west. - No correlation was found between the presence of wireless communication facilities and declining property values in the various monopole studies we reviewed or carried out on residential communities in Suffolk and Nassau Counties, including the North Fork and East End of Long Island. - The Applicants' proposed Communications Facility, therefore, in consideration of the above and if approved, will not negatively affect property values in the surrounding area 43A 11 and will not have any adverse effect on the character of the neighborhood or the pattern of its development. 12 ADDENDA ��� 13 Photographs t" Photo 1: View Looking Northeast at Property from Main Road N . •T 1 f View Looking Northeast at Property from Main Road 14 10 i'Ago& _ s Photo 3: Property Looking South from LIRR in Direction of Proposed Wireless Site y ••i a S r ._ 0 Photo 4: View of LIRR Tracks Running Immediately North of Proposed Wireless Site ISY( 15 Photo 5: Associated Office & Sales Building Abutting to West of Property on Main Ave. aT f�3 -max �•�ya,_`f' Photo 6: View of Associated Storage Lot Abutting to East of Property on Main Avenue 16 It Photo 7: Albertson Marina Diagonally Opposite Property to Southeast along South Side of Main Avenue i Photo 8: County-owned Wooded Land and Wetlands Opposite Property to South along Main Road 17 X'- t A .r F i Photo 9: Town-owned Lands & Preserve Opposite Property to North, Abutting LIRR ��` - `ter`'"•- ._i�``.�._ w r - M Photo 10: Nearby Residence to West at 445 Budd's Pond Road. View is of Rear of Residence Looking Southwest from Main Road 18 . 1 Rum s F Shoals Motel Further East of Property along South Side of Main Road r r Photo 12: Shuttered Restaurant Further East of Property along North Side of Main Rd. � �'. r �r v �v4`w. i� .rs�f.w _��V ._.._ MRl� 1 lw~ �� '�`r� ...-.-^'".r""'.. �. ,. ,#._ ..n. 4 y� :?e"`� '.rk '�yi a� 4 'x., � 1 1 � 1 i ' �;, �� � � _� � — --""'.�.� 7 w , _.■ --� �� . `�--. 1 4� � 1 1 ' 20 Google Aerial View of Property & Surrounding Area, Oriented Northwest 21 Suffolk County Tax Mail Oji >•.. a rim-' �. \ ... ,g '� ��`. �a� y' ..� ire �r R 1P�.�'�'- •i • : 8. mr. Po ra. � � �A\ .a ``f � ,,� � S a' • f 4 ar.wr fA M_�fl'a•• 'G �' �' 1 p�\\\\�����s°�''r /'•" ii•�e Y. +,• 't'' Yom."!��f ° _ >..< •'i °� •; , ' 1� cl .b� 2.2 1.2 2.3A(c) COUNTY :•° a+; N ,;. �A �' OF SUFFOLK COIMU 6 •s; o fa I •/ TY r �o © 056 a a Ips / I. �awmRI k4fMH1.Y♦0 ANDIQMS PF]mMJ gW I / a LOW ewe, uu rants == .wcls.�%IN A—MM r. _ 'L\\ 1 E 4g w+eo / "P ` M.M mNRYA+dI SWV ral -Y+O�e � asn ox s�lE surrtT er gmrwv 6NO185mRi a unoc / PL s m.—N N E ANm PE LS u@6E/IPEEI• li�tt T[.of ap t* y^�• PVW,wurc otsos axAlt a oowvarm Tmx Il1aR m11vN= TIR pgOPOgU=a m 1OEo0YwN�GTgNs AMO m IDT ommm iml P�my�Ml rlwmTx OCFRAI0.1'rxvEiDla,Pmlar am sAgtAlflw u ND A®fmK�L Orl-SRE PALM AM W fEmWFA ff v ELSD[I e. 1N[rNd11Y 9ULL VCOm ml n@ AYOIIQ Or mKY A YMM rOII F� f EORIIm 1 YIIdEDRm NaI bay ■ Au YATaEIA.R S%S ®AaaWtmEE 1,CA NdSr LC TOffh A C^Wff IVOft FAA ML AWAR SCAR PWMR"STAlmYD4 _ euw Tobe a� AunDAm IIPFLSNA1mIW^, y _S �z q T. AwEw.s:°LAf@�YtF9SPE�qu .Tw® 'la COKMWM suu comer xv Tmu UN-G laa waa rowmNGEM" r.y _ ro TION"^ SWAY A-- 9 •�cTM ra AATA ar emtt Pod ro,Mr smn a ANr ocAwuwl. O �� 1 t+.� � MfAR� T ,].mamODiAa OIOm4SaaD4 6'NR,AAL IIOT mmbL lob * 4 t I Y N�OIO Is ALL AI6A9➢allD® bWOtx CONlm6.X.N ACT AAE M St�ro � II co+WWo Oi � PAE�f�9p L b•a:I 14 Tim¢NQ NO"TER YAfbS.SArATARr alFn^.MI iLT15,Oa1dD wNp r• y AbKcen.IN 8a \\ A'LpMPpC 5mr.m[EIDNmV B.L9NY Prmq¢p f6a MC PIDgFIY. O i p+R 8 RW 1 Rw IT 1 %1 a IS W WW_9 ffi oA,Mfia atVOmRATW ml wHa rant 1 IS wK mumARL S�gaN,E 3 I _ It rao,meL t"�' i S �611f6 B v 1 t 16 TxOS AAE No PROPIAr ONCATO*PR6T£Ja roan I u � �� ur� .b � � i 17.No TPAeQYA'/OrP,G9 oq mwcrmuz NO[rAOPOsm r,n as sne Rb unnia £ k� i le TII®E orWNa9 AAE PRoimm roA mqm uwnnua�cN uva TreTw+o.m Teio��` u ,' �� /� me ec x\mePm smTs6eu ro THE m DTLs ^V� �, "rTw".oiw""°°ro CD wiO 1 ,0. SO2 PUN Itl.4D ml mrE SUMP Hf AtNAIGDT VMCSW•IND r„r 6LM4 iD PL 90®9f mFP101 G PNM Pt L4 IICS]6E/DEM a � 1O/Sf/,R jEREiY K M.KEON i-- _, _._ L.— SITE INFORMATION: 61TEN6.BLBERSSORMARINE O SAT26.27"W - u 200.00' � b140ET1ADiROAD (l I'Slmlfj TL 1 Grt_je-_ _— 4m wmb 6OUTHGLD,NYlM ISE \ \ ¢ail NrPw[r baa'O m.nO AOEFOLKCOUNTY F/ 1 1 O MAIN ROAD (N.Y.S. RTE.25) t sED• OD TE EN PO E 1 \\ 1 _ y W3� T=�� o cv�b� I 511E PIAN n�iv N N Y ................................. ......... .. ....................... ..... ..... ......... ............ ................. ...... ............ .. ............. ... ............................................. .......... .......... . ... .............. ....... S A• NOSES: �/��/{��J�_�\�p�i/I/Jp) All 'K I. NOE N1FX tINGwiOnMAnON SHOWN FOR CSAaffT. `V/ ` //// 2 COHPOUNO RMI EASED ON SRFSU0.VEY BY•VIERICNIENOtgFPwGelANO 6U0.VEYwGP{.SIGNED ; s�%� IYSTIiHEwEM PF.LS.l1CBI5E NO.x%018 OATEDIMVIO Q i NNM LOCATION OF EOUMEMTOBECONFWIFD WRN OWNFAl ELITE FFWRT S CONn0.UCTION. X. LO GTIONANOINnH—ON Of FpUIPNEMT00EMACC�RDANCE WITH THE GTRUCTVPAL FROE)TO EE ACMINET RY 4 AN NMS.TOSHXLIGNTOB EXISTING XISTIFSSOPOSEOB•4•x 10CfR6PBN 0- EUTq TO BEwnMLED ON . AZIMUTH S COMMCTORFHN OBE AllEXISTINGCONDRION9%UO0.TMIGBORTOi WORK. EpU6HFM PUTEOPE MNVDPNL iROFOfID TPEE 31 H—EANofl E.ABOVE G FlNAL DEIGN Of xEUTOeFCONEI0.MED ONCEEIITE NAS TEFF ORNCOAGEOTECHNIGLBORWGAND TflEVATFD]MOVFGMDE ON (OTOF O TLp ~ {RGVID®AREOAT. C�NCRETE— (@IER.VD WHFIARB00.VITAEO.O'TAIS Nw.) OD ELEVATION I' -- $S EDW nAGE0.PATTFAN TO CPFATE ✓i ^ � (sEEDFTNEIll,(HEFT 2-Iq MA#MUM CONCFAW@R YFNq - - _ (SEEDETNL9.fHEFTZ-Il)R IAOPOS®US¢IfTH{MNE� C:', "t� (TTP�Oi�ITEE OETNLSSHI71 LInF T00.IRSIP oHiMHEHOt I�SED 1•.___.......,,,._ µrts aaFMwG.G—Nc -- --' aNJssoRNEa(er Eurp4,� D cnouNoo6iuRaANCE��" 4 f I 0 0 0 0 0 0 0 0 0 0 0 S01lTFtOLO O D O O O O O O I gIOPOBED POW E0.CONONT Q ROUSE°Fa TRANSfORNFA T METER BANK O OEE DETM I,SXEEi 2-Ill BROB--WST—CABLE B%OGE t) O ——W'4'AGL(SEEOETNLx.SHEET Z-Iq ,_E'- _ p I( O {AOSOSEDVEMC Y—EH O L--- i L------- i 1` OPEN BOCKET EUTE) uaR�a I I oN99 R I a D i mI O I �EpLRFNEMMFA� i A� I i �E TURF � i p j--/ FY S �ACEfC1>a' I pDB,le1TARDR � . I I I WIIP D:SCON ECT(BY ELTE)PACK ° --- TO DISCONNECT(BY FLRq �w TSO BE Wn.LLIFD ON Hf MME NJD AS W. WA9 )KN L---0 — /u ATEpABDVEELOODEEVATION 1 D r — BRO—FIREpnalcrwsEs aOUFFD ON I / H1pPO5FD N•awID 111 M 1 —Ro P—®VER20N m cmu77.. A%CABIET FOS®CNIEBFOIEDT BIDEDISTNCT rE�wOF]x0'U7(BYEIRq 4 ROUTED ON FAOFOSFOF 4 FIE-TON 12TMW) I j' `NR I EOUWIfNT iO RlOPOSED TOWER(STPOP I) —_/ (SEED AS I.OHEET 2-la W M O (TYPOFH FF0.fECTO0.NTOTM) ( i Nwn �^ FROSOSEDVWRELESF WITH BEpU ED \ I ® 1 w V 1 e d.uxn KN b Ate_ A YVFRRON WIX cE EEITHw PROPof® r 1 ° � ----- _--- --- � coNDwrENr PaE RFF SHEET zoy \Iw �4 les•ro wErwroWD r m O J FROPOSED 190'HULTLSECTION I on ULn.pDED PADOHE CS / CONCEALMENT iOWBi(BYFUTq I I � .� L ° I 1 Ri0105®TO.)FO•xl5'T ECARPGA ♦ RAw Sp.fTWUrI@IT I I � � �'+ O � � COMFWNDQYELSiq 7 I �EOUp11BIT AREA I N"y 7 TIT L ° - - - - - FRO—1HIGHeuc --llCE fBY ELHq SITE INFORMATION: oNWIRELE UNDEIOROUNo—..TfltO \ 671E Nd ALBERISONMABAIE fRDPOSEDYFPEON WIP8ES5Ida•xWO'nft—ONI �OIIDMVR(BMYSYEaiOw WIRELESS)RCRRED BROH METFSS RACKa 1 (( NW9SE Eq WRx FT-) �� TO FROfOSED WL TftCO WWET ON I I I 61405M"ROAD nFEltAWOPVR9oQ%L)INA190'x10'L'IEKEA IlW�=afl SEDT EQ—EHT TBOPX(SEF OOTAS I a 1,SNEFT Z-ID I SDU7NOLD.NY1197L SOPFOLK coumY \ wrsDEC I.I.—E. SCIEYYPE, ANO Gapu�Daiu wlWL-1 DF E a `DonWGBVIIDVIG� wEn.w01COEooTADACENT 150'0'0DNCEALSffM POLE AREANmTowNamrrHOBD wET1.vID BuwmcnoNN AREA PROiOSEDVEFZONWIRELESSUNDERGROUND mr.,m oiL i ��i•ems SOTE S —111 11UTBETY �.n ",3 m LTFEHCE%TMWBMR ANDOTHEREF-ONMIDSAT WLLTOTRWffOANERB NFSACABWFf COM T W WILL BE WnAL1FDNm HANTAwFD DUNNG iRgECT —4ENECFSYEDMDREYEMADVD ON YET-- 3 1 COMPOUND PIAN •u• .'"';w Z-08 ... ........... ...... . ....... . ........................... .. ..................... . . ..................... ............. .... . ...... .. ... ....... .................................................... .. .... ........ .. . . .............. N v W x 9 I AZIli/IUTH EUTII0.ECARRIER I iRCPOt[DIBB'MULN-SECTNJN ' e I EOIAFMM AREA Ml4TI,8DED PADOME I I CONCEALHENTTOVIER(BTELTE) L----------------------- ---------- Eutr TOxr0.HP I I I I SDUTXOLD I I �PROPO6EDV ONN9RELE4]YOCONCRETB I I PER pP OF 6)(9EE DETA4L SHEETZn) PROM VERRONWNELES GPSUNf I I MOUNTED YU'ABOVE PROPO�CWJOPY (TYP OFI)(6EE DEfA45,SFEFf ZIS) I I I I PRCPOTEDVERq:ON NtPELE4 PROPOSEDYEPRON V.IAELE55 DU4.BAND PAH UMT(119 I I StEFI (ABOVE) OF 3 PER SECTOR 9 TOTAL)(SEE DETA429fEEEL11} DFH (TYPOFIPERSECT00.3TO71I(S WA1L6, iR00�PCF]�ffFDET(N B,6HE Z 91EEf ZIS)B i.PLEXEFORR HOURNTNGoF PERSECTOk3TOTALS) A+m,s r------- PRCPOSEDVEWZON r------PROOSDYER20NVVURELE4 r N9REIFSSBATTERT UBN4T I LE WCABINETI K4IOYIPI WAS 1Rn (SEEDUA4I,SIFET Z-13) (SEE DETNLI,9IEETZI3) I ---J IR mml u,maw..em P JA6 I ME PIOOSEDVERRON NiRFlESS CABtf �" 1R' PROFVaEDVFRZON WUtELE4 PRH RNI ARN RRH �/ BRIDGE(SEE DFTA4 P,SHEET Z.N) �'� la JAP Ip dscowaEcr svmcn noLwrEo TO PROPOSED H-FRAME I PtOOSEDVFRQONN9RELE4]/B'O COAXCABlES a Pn RourEO ON PROPogD CABLE eRIDGETOTw.sR ,w„� r„ no I 1 I I (rnoFPPERgcraLlYroTAL) ,m rl, >m L —J ffl 'IEREMY K McKEON G I bT1EN0 AIBHRISONIMME FROPOEEOVERWNWRELES UNDERGROJND l I PON�BTRWJSFCCRJ'ER&MESA CABINEF UTNTY 814p5 MAIN ROAD / / I (YF DEFAa 151 kIEET za1) SOUrHOM,NY 11971 I I I I SUMMCOUNTY sriElm L-------J L-------J L-------J 150000NCEAMENTPOLE PROPOSEDVEP NIRFLESSPYTALLMAN L T T T T T T T T mm�^�'®FP✓�� PROPOS(—OfEm"EDEAII.E. IL UG 1 F v �p (ilR Of?)DFE DFTA4&Sl1EkT Z�I]] D PROPOS VERQONVNtFLE4 PONERSTELCO CABINETS MOLIMED CN PROPOSEDHANDRAI yTUBI.�aT PIAN 1 EQUD?hIIIVTPIAN `ey, xvea Z09 — � N .P 1 TOP--M 3 FROFOffDRREC`='C` —� d1TWRNRRPNVTFNNAS E AMENNA MOUNTEDAT TOP OF EL=161LI0'x AtT1� coNaA]nErur PGLP Erna I) (SEF SHEET Z-16J Vl, PROPOSEDS•d' rAu PPE nouM(rw of�) PiOPOffDPRE Dl6TRIR AZIMUTH EQLRMEM(�E fffFFi Ll6) TOPCEPFOFOSFD cwcilrcc.ri ac TOPdAMETEROFRADOME CONCFAIMEM POIF� MULPBERICN MULTIACED y`}7EGr:Q - § CONCFa1nEM POLE=1o• �� 1,::. -'� ❑.nt 1'DN Eas Lr P20POSEDVHBZCN WIRELESSAMENNA RONSEDAMEMJA MOWTFDWRHINCONCEALMEM POLEN'Y=196'-I-I iAGL - (rnOF2PfAffROR6TOTAL) Ue. (SEE[ITNLI,$HEETZ-II) 'I Fl•.� FROPOSEDTWREXER(I EERIIROR.]TOTAL) PROP06EDAMFNNA (SEE DETNL S,AiEEi 2-IS) II —T�NTERUN'�=111'-�'S 4� FNNASECTION OF�( I III FUNREANFENNA vefton ll�l TMERUN�c=140•x0.G1 ! 00TTCM OFA ION ! a � �TL.RDC7' �I K �.m 1!I� Qr ASSHdNN wAs 11V1 A11 6Li „a,r!G+ !ws BOTTCf10FAMENNAffRION ! � g � F �r la Pry II�1 J ,em V IFS 1�III l� 1F% �I fUTUREMSIENN4 7F3 ����I� —2FMERUNE�'O•SAGL Y Ir+I !AS Y{1 .F .EDFIREDISTWCTCABLES ROUTED &ESWvnOU /�BOnCM OFANTENN4¢KION I w1 THINCONCFAIMEMPOIFTOHRE 4�Etaf6f u' C� !I D9WRANFENNAS(rYP0FI) III FUTURE MITFNNA1� ✓fRTEklP7E=9d'4 aL1-y '1 ISI` PEOPOSEDVENZ WFELESS—COAXCABLESRCUTEDON 1- OPOSEDCABLEIIETOTOw 111IPDFSECTOR Il TOTAL) -•%� �nCM OFAMENNASECTION ! t PROTOffD VER¢ON WmwcrcDVALBANDRRN UMT(TYPOF]PER SER0R.9 'IERE��KMcKEON �.�� i roTay/SEE OEraLzsnxr z-u] kw ttl .oF(TYPOFIfERffRCR]TOTALJIffEDE(SEEMEETZ-IS)BT'P) rveR um' vwn m5 I�I (Tw.OF I PER SECTOR]TOTAL)FORMOUNPNG(ffE DETMz SNFET Z-IS) 1111 FUTURE ANTENNA sM��i�acs EAff DBVi mCi RADCME III ���ERUNF=TI'VS AG vamtm F.rtF na mawT. MIAT1,CFIONMULTSIDED illl CONCFP1x1FM PdE=b' ,II1 Ci` 174-WDEAC=GATE( OF2z6.4T(BYEUTE)ISEEDE-L I.FHEETZ-1]) SITE 1BERTWN0N- J III SYlE ITE INFORMATION: ATION: iE J�TOPRBASEP� Lm q1 OFAM FfffTION 10=,IMI UBWET(BY FUTE) �A4 PROPOSED,IMI=E'1 El 11 GBMET CN 1'd'a6'd' WgBSMAINEOAD PROPOSED VFIBZON YNRELESS UBEE LFVATED EQUdMEM PATFCRM(SEE 41EET2.16) SOUTHOID,NY 11971 BROGE(ffE DFTA0.1,SHEET Z-It) gpS�yglpON wiREEE31 UT41tt METER MOUMED IN NEN EOCKEr(BY ELITE) SUFFOW COUNTY PFOPoffDOER¢ory w6¢EIE55 TCP OF VEGZONNIRELESSGP9UNR �� �(��) MIPACK -.CT Ily EUF11 SITETYPE PF,—EDOXI0'4-MFMRKTEDEQ—ENEPtATFOHNTHNANDRA4 150'PCONCRA1IFtRT'rrPOI.E PtOPOFED�FRRCN`MRELESS GFS Ii EIEYATEDY ABOVE GRADE ON CgJCRETE PIERS TOP OF ONNtRErE03 UNWf AMENNA MOUMEDON PROPOEFD (SEE DETNL518244Ei ZI]J u� CANOPI(6EECETNl091EET Z-IS) fL=IVO'xAGL =II'd•f AGL � TOPOF PRE DISIRICTF UIFMEM C.t01MT ® - = PRCPOffDVEA¢CN Vf�FFlESSEQV6AFi]T CABINET& �0�'�,$�m BATTF0.YCA01NET(BETONO)ISPE DUAL I.SHEET Z-I5) TOPOF vflt¢CN WIAELFA GANNET ..d,�� ®. B A P8'fl.� m PR0P0SED6'O•MGHBUaKC NUNK FENCE Y {(+ �,�(1 O TOPCFCI- UNK FENCE (BYEMiE)(SEE CETNLI.SrffET-I]) -�'•• j _ �l, X'.bS., •a�zNcco �j i; BOTTOM OF a1FQlAP•aflT ¢BVATION Ln S'J'ANSL " �••, St Pum a 1 SOiJ'lifI EA3fELEVATION Z-11 N / d'sh �`--_ WI cwsUNOSocr.Pc. °n'nc„"aimi. / vAn .LLC rQ ,• 984-E ;:+a_fl-_- �� - 'h is /_=,__R� r. m�..d.�� ,�.•. - -- =__- - -- --_=_�__ /AZIMUTH rQ r ��,- •d .R,oKlw r� Wz �. �� I - / i �i wessµotowH aiiwr�ao rA �,v. -�D �.\ tlu�oluwswcrwrul...w. r M mazz, MNQ/ r ipsB I maY B omm R Y ■ .RV A9 .901 �� •L �� wirium m�o"iur / .srwum*owrVa souriran / C u '� ♦ CON DMUMENTS enwNorvamirnoruinxew � 3 ! N ! W ,mno,art—lli.ccas—E-.e aim•rcas • aavw.—.0.L—wore scar DALE �,rH ------_------- n ---- -- ! n ronHumov�a oL TMeLlcnrtro�verJ r• n / — -_-'----- L ♦ —i. — . — — . — . L. � LL. — ♦ � � / •.c wmcx.T comm __ NTNYCO2ZS9A 547'26'27 ____--1-_ _ I � WZ LLsx�y5 pis�� NMCG2239A ewrmt�socu ewe e \ 1 81405 MR ROAD.ROUTE S - o+c•+row+c.suxveaw \ 1 SOUIIRHA M 11971 uvmscnawrternweµo �ao�...�«�x„•o.a•� MAIN ROAD (N.Y.S. RTE. 25) : „rTE 1 { OVERALL SRE PIAN _ 1 \ W3 —� i � swa worms ' ♦♦ A-1A OVERALL SITE ma ® 1 Lr srr IJS vsV�,mL a.-Wn/raL Ch N 1.b a�mwam • t bM OgyNr�aOl INmNwr.•mr�Mu�mO� dish M&lI�,LLC 11191 mum mW rt urtaElul, Nim /AZIMUTH c miner m a a Nox Nom m�oem.�e �� � '''Ilaaur OIOT AyD W4 a�a u>an0 sm P'alwp w #O�o o o 0 affin •a w c xv�r mme to w9amvun, 9I9e. %23 r I I mwmj� 9 CONSTRUCTION DOCUMENTS p+ maertws Q•reax u•a1r ^ Nom owl • `-- �Rfm a�.m IwNaaln o �.«.. ONlNie Or • Mw vNN� vo .e O.9.W •L mNF9�xm®t HYMYCO2230A fa9i mamas PfOffi9 Y9aNapN NYNYCO2239A 91409 MA07 ROAD,ROUTE 23 SOUTHOID,MY 11971 scar l IE ® COMPOUND PUN arlwu® NIB®/1111 HEET/6WtffA A-1 C 1 NII N11�,.,,o.I.[ImI•I-9VIIpm N V S� 00 N r� 3lna3p5 aNv moan VNN31�'�Y/313 IM 4(84'AN VMH= - U 3NION mm NIVN wrl9 �nrd...oa®yrmm nranm•� �A _ v8CZ8OaANAN ® dd m .nm� w ru�0i4o�a>�rO1 vN¢axoauuN ___ rue b.nmr tea. .0 r . -'°' m"}'q o-am aw 4■ r e,�.0-.m.m a =Jd e mw0—%—.—MCsIi 9 as SLN3Nf1000 N0117f&SN00 r erg Zms. uo xsm ®'ark -am«e oaorN . . IT MOO. H1RMEV r w u r�• V��iO�wwvw� �grmr�oiti a�ou v niiw xu.s�iun .ao '�O® oil' IM ASAP A • s.'IV ftleAl llN rOYem 1 � s eae race wpm m E.xen sr aaml s er1 • rsr ue un mmeea ruame exE s �/ ,o®oEI rwssrs r-r x,r-0r wssx eeeux uxrpr x pralar c+ra e.E v ,eslE.emn erx®moor wsrar do sEE aAE ree��o, >.9xe,or oar aElm ru alceY .LLC s h Pn��O�u em,sea unu3m w cE o pry AlaI eesr,ew roar era wxr Or mllAO� j awrr,n®x-aoe \y; mW1�Pp tea'r ,v®oN wem w sm,re ,-, r- -------- ----- - ------------ /A I ZIMUTH ewmneewwr pre I 90 E M.ILSEY�,p 91RI[1M IIV®oal ' . , I I I '— _ I P�IWfNdt wRIMRAA, ir 'wn'a.m ,e m m rA IS.Y r. 3 CONSTRUCTION i I DOCUMENTS I � axr x §. . N-III .:� i K^w -- -------------- . w,i. ter® n est® aWr o:e.� --- mnea ro, ws®oMerr O,wI�r orris A so3A-O mo•oe�ewr .at wRam e� NYHYCO2239A IWI WW=PM=XFOWTIM a�a rim' NYNYCO2239A 61405 MAIN ROAD.ROUTE 25 SOUIHOU),NY 11971 prom w Eo®,r x,r urs M.4 EQUIPMENT PLATFORM AN H—FRAME DETAILS or Im ru,® E E1®M'1n 9rEryryT MIW®i f11r en E✓tE LIG meWC�>--Avg- N 30 CERTIFICATION °1 I certify that, to the best of my knowledge and belief: 1 . the statements of fact contained in this report are true and correct. 2 . the reported analyses, opinions, and conclusions are limited only by the reported assumptions and limiting conditions, and are my personal, impartial, and unbiased professional analyses, opinions, and conclusions. 3 . I have no present or prospective interest in the Subject property or personal interest or bias with respect to the subject matter of the report or the parties involved. I have performed no services as an appraiser, or in any other capacity, regarding the subject property within the three-year period immediately preceding the acceptance of this assignment. 4 . my engagement in this assignment was not contingent upon developing or reporting predetermined results. 5. my compensation for completing this assignment is not contingent upon the development or reporting of predetermined value or direction in value that favors the cause of the client, the amount of the value opinion, the attainment of a stipulated result, or the occurrence of a subsequent event directly related to the intended use of this appraisal. 6. I made a personal inspection of the property, which is the subject of this report, on September 26, 2023 . 7. no one provided significant professional assistance to the person signing this report. Michael J. Lynch 31 ASSUMPTIONS AND LIMITING CONDITIONS This report has been made with the following general assumptions: 1. No responsibility is assumed for the legal description or for matters including legal or title considerations. Title to the property is assumed to be good and marketable unless otherwise stated. 2 . The information furnished by others is believed to be reliable. However, no warranty is given for its accuracy. 3. All engineering is assumed to be correct. The plot plans, drawings, and illustrative material in this report are included only to assist the reader in visualizing the property. 4 . It is assumed that there are no hidden or unapparent conditions of the property, subsoil, or structures that render it more or less valuable. No responsibility is assumed for such conditions or for arranging for engineering studies that may be required to discover them. The report has been made with the following general limiting conditions: 1 . The information contained in this report is specific to the needs of the client and for the intended use stated in this report. The appraiser is not responsible for the unauthorized use of this report. 2 . Possession of this report, or a copy thereof, does not carry with it the right of publication. It may not be used for any purpose by any person other than the party to whom it is addressed without the written consent of the appraiser, and in any event only with proper written qualification and only in its entirety. 3. The appraiser herein by reason of this appraisal is not required to give further consultation, testimony, or be in attendance in court with reference to the property in question unless arrangements have been previously made. 4 . Neither all nor any part of the contents of this report shall be disseminated to the public through advertising, public relations, news, sales, or other media without the prior written consent and approval of the appraiser. l 32 MICHAEL J. LYNCH Certified N.Y.S. General Real Estate Appraiser#46-1012 QUALIFICATIONS Zi Real estate appraiser since 1981. President of Lynch Appraisal Ltd., located at 15 Dewey Street, Huntington, New York 11743. Appraised various types of real property on Long Island, New York City and Westchester County including multi-family dwellings, apartment buildings, commercial property, factories, warehouses, R&D buildings, office buildings, large residential estates, residential and commercial subdivisions, boat yards, and special- use properties. Prepared appraisals for use in estates, estate planning, feasibility studies, condemnation proceedings, tax certiorari, and matrimonial matters. Specialized in testimony such as special permits,area and use variances for properties. Applications have included proposed wireless communications sites, fast -food establishments, convalescent homes, gasoline service stations, convenience stores, multi-family residences, new construction, etc. Appeared as Expert Witness: Nassau County Supreme Court. New York Supreme Court. Town of Babylon Zoning Board of Appeals. Town of Babylon Planning Board. Town of Babylon Town Board. Town of Brookhaven Board of Zoning Appeals. Town of Brookhaven Planning Board. Town of Brookhaven Town Board. Town of East Hampton Planning Board. Town of East Hampton Zoning Board of Appeals. Town of Huntington Zoning Board of Appeals. Town of Huntington Planning Board. Town of Huntington Town Board. Town of Islip Town Board. Town of Islip Planning Board. Town of Islip Zoning Board of Appeals. Town of Riverhead Planning Board. Town of Riverhead Board of Zoning Appeals. Town of Shelter Island Zoning Board of Appeals. Town of Smithtown Board of Zoning Appeals. Town of Smithtown Town Board. LYNCH APPRAISAL LTD. 33 Appeared as Expert Witness (cont.): Town of Southampton Planning Board. Town of Southold Zoning Board of Appeals. Town of Southold Planning Board. Town of Oyster Bay Zoning Board of Appeals. Town of Oyster Bay Town Board. Town of North Hempstead Board of Zoning Appeals. Town of North Hempstead Town Board. Town of Hempstead Board of Zoning Appeals. Town of Hempstead Town Board. Town of Shelter Island Zoning Board of Appeals. Village of Atlantic Beach Zoning Board of Appeals. Village of Bayville Zoning Board of Appeals. Village of Brookville Board of Zoning Appeals. Village of Cedarhurst Board of Zoning Appeals. Village of Cove Neck Zoning Board of Appeals. Village of East Hills Zoning Board of Appeals. Village of East Rockaway Board of Appeals. Village of Farmingdale Board of Trustees. Village of Farmingdale Planning Board. Village of Floral Park Board of Trustees. Village of Freeport Planning Board. Village of Freeport Board of Zoning Appeals. Village of Garden City Zoning Board of Appeals. Village of Garden City Board of Trustees. Village of Garden City Planning Commission. Village of Great Neck Zoning Board of Appeals. Village of Great Neck Plaza Board of Trustees. Village of Great Neck Estates Zoning Board of Appeals. Village of Hempstead Zoning Board of Appeals. Village of Hempstead Personal Wireless Services Facilities Review Board. Village of Island Park Zoning Board of Appeals. Village of Lattingtown Zoning Board of Appeals. Village of Laurel Hollow Board of Zoning Appeals Village of Lawrence Zoning Board of Appeals. Village of Lynbrook Board of Trustees. Village of Lynbrook Zoning Board of Appeals. Village of Malverne Board of Trustees. Village of Manorhaven Board of Zoning Appeals. Village of Massapequa Park Zoning Board of Appeals. Village of Matinecock Zoning Board of Appeals. Village of Mill Neck Board of Zoning Appeals. Village of Mill Neck Planning Board. Village of Mineola Board of Trustees. Village of Munsey Park Board of Trustees. LYNCH APPRAISAL LTD. . � o 34 Appeared as Expert Witness (cont.): Village of New Hyde Park Board of Trustees. Village of New Hyde Park Zoning Board of Appeals. Village of North Hills Zoning Board of Appeals. Village of Muttontown Board of Trustees. l Village of Muttontown Board of Zoning Appeals. Village of Old Brookville Zoning Board of Appeals. Village of Old Westbury Board of Zoning Appeals. Village of Oyster Bay Cove Board of Zoning Appeals. Village of Oyster Bay Cove Board of Trustees. Village of Oyster Bay Cove Planning Board. Village of Port Washington North Zoning Board of Appeals. Village of Rockville Centre Zoning Board of Appeals. Village of Roslyn Board of Trustees. Village of Roslyn Harbor Zoning Board of Appeals. Village of Sands Point Board of Zoning Appeals. Village of Sea Cliff Zoning Board of Appeals. Village of Upper Brookville Board of Trustees. Village of Upper Brookville Zoning Board of Appeals. Village of Valley Stream Board of Zoning Appeals. Village of Westbury Board of Trustees. Village of Westbury Zoning Board of Appeals. Village of Williston Park Board of Trustees. Village of Williston Park Zoning Board of Appeals. Village of Asharoken Zoning Board of Appeals. Village of Huntington Bay Zoning Board of Appeals. Village of Islandia Board of Trustees. Village of Islandia Zoning Board of Appeals. Village of Lloyd Harbor Board of Trustees. Village of Lloyd Harbor Planning Board. Village of Lloyd Harbor Zoning Board of Appeals. Village of Northport Board of Zoning Appeals. Village of Northport Board of Architectural &Historic Review. Village of East Hampton Zoning Board of Appeals. Village of Amityville Zoning Board of Appeals. Village of Lindenhurst Zoning Board of Appeals. Village of Lake Grove Zoning Board of Appeals. Village of Bellport Board of Trustees. Village of Patchogue Planning Board. Village of Patchogue Zoning Board of Appeals. Village of Port Jefferson Board of Trustees. Village of Quogue Zoning Board of Appeals. Village of Southampton Board of Architectural Review &Historic Preservation. Village of Southampton Planning Board. Village of The Branch Zoning Board of Appeals. Village of Head of the Harbor Board of Trustees. LYNCH APPRAISAL LTD. 35 Appeared as Expert Witness (cont.): Village of Westhampton Beach Board of Trustees. Village of Westhampton Beach Architectural Review Board. City of Glen Cove Planning Board. City of Glen Cove Zoning Board of Appeals. City of Long Beach Zoning Board of Appeals. PARTIAL LIST OF MUNICIPAL CLIENTS Town of Oyster Bay (Office of Town Attorney) Town of N. Hempstead (Community Development Agency) Village of Muttontown Village of Centre Island Village of Upper Brookville Locust Valley Water District EDUCATION Hofstra University, Hempstead, New York: BBA -Management(1983); MBA - Banking &Finance (1991). TECHNICAL TRAINING NYS Department of State Real Estate General Appraiser Certification#46000001012,Expiration 12/21/24 Appraisal Institute Real Estate Appraisal Principles - Exam#lA-1. Basic Valuation Procedures - Exam#1A-2. Capitalization Theory and Techniques, Part A, - Exam#1B-A. Capitalization Theory and Tech. Part B, - successfully challenged Exam#1B B. Case Studies in Real Estate Valuation- successfully challenged Exam#2-1. Standards of Professional Practice, Part A (USPAP) - Exam#I410 Standards of Professional Practice, Part B - Exam#II420 McKissick 7-Hour National USPAP Update Course (11/18/22) Columbia Society of Real Estate Appraisers Fair Housing, Fair Lending (9/12/22, 9/14/22) LYNCH APPRAISAL LTD. 1"10 Carpenter&Cross structural engineers September 22,2023 —7 P3 Town of Southhold Building&Planning Departments Town of Southhold Annex Building 54375 Route 25 Southhold, NY 11971 Re: Design and failure modes for a 150-1t.Slimline Pole RECEM (Pole Designed with a Theoretical Fall Radius of 72'-0") ocr Site Name: Albertson Marine/Southhold 4 � 5.2023 Property Address: Budd's Pond Marina,Inc. 8OARDOFAppZ" 61405 Main Road Southold, NY 11971 C&C Project No: T230140029,1.022 To Whom it May Concern: As detailed below,the 150-ft multi-carrier slimline pole designed by Carpenter&Cross—Structural Engineers and fabricated by AIIFasteners at the captioned site, and as depicted in the Preliminary Design prepared by Carpenter&Cross—Structural Engineers (Project Number T230140029.2.026 dated 9/21/2023),will comply with all applicable federal,state,and local structural standards, Final Construction Drawings will be provided at a later date. Monopole Design Standards and Failure Modes: • This slimline pole structure was designed in accordance with the latest revision of the ANSI/TIA 222 Structural Standard for Antenna Supporting Structures, Antennas and Small Wind Turbine Support Structures unless otherwise requested by our customer.This standard has been approved by ANSI/ASCE, which has dealt with the design of antenna support structures for over 40 years.The TIA standard, based on provisions of this nationally known specification, has a long history of reliability.At its core philosophy is its first and foremost priority to safeguard and maintain the health and welfare of the public, • The TIA standard designates a minimum wind loading for each county in the United States. Carpenter& Cross uses the wind loading listed in the TIA standard unless a greater value is specified by our customer. Structures are also designed for radial ice at a code-specified reduced design wind loading. Code designated coefficients are used to ensure that the structure will survive the designed wind speed. The structure can usually survive even greater wind loads than the basic design wind speed because of these conservative coefficients. • Failure of a steel monopole occurs when a point is reached where the induced stresses exceed the yield strength of the material. At this point,the deflections induced in the material are no longer temporary. Hence,a permanent deflection in the monopole would exist. • The term failure above refers to local buckling at a designated point on the pole. Local buckling does not cause a free-falling pole; rather it relieves the stresses from the pole at this location. Monopoles are flexible,forgiving structures,which are not generally susceptible to damage by impact loads such as wind gust or earthquake shocks. • When local buckling occurs,a relatively small portion of the shaft distorts and "kinks"the steel.When the pole begins to bend,the exposure area is reduced and,therefore,the force due to wind is decreased as well, Even though buckling exists, the cross section of the pole is capable of carrying the entire vertical 5650 Blazer Parkway,Dublin,Ohio 4309.7 T 614 289-2977 www.CarpenterandCross.com Fall Zone Letter T230140029.1.022-Albertson Marine/Southhold 4-150 Slimline Pole September 22,2023 Page 2 load.Therefore,wind induced loads would not conceivably bring this type of structure to the ground due to the excellent ductile properties,design criteria,and failure mode. In addition, the monopole can be designed to theoretically fail at the 78' elevation by purposely over designing the pole sections below this point. In the unlikely event the pole was to fail at this point, the significant loading reduction caused by the removal of the tower wind area and weight above would greatly reduce any chance that the remaining tower would collapse,thereby providing a theoretical failure radius of approximately 72'-0"for the 150-ft AGL slimline pole, We are aware of Southold Town Code section 280-70G, which generally requires a "fall zone" of an area surrounding the proposed antenna support structure by two times the height of the structure.However,we submit that the Town allow the smaller fall zone as stated in this letter. Monopole Coordinates: 41°4'33.69" N,720 24'21.72"W I hope these comments address any issues that you might encounter relative to the anticipated performance of monopole structures and quality of steel fabrication. If you have additional questions or comments, I may be reached at(614)289.2977. Sincerely, ,tP yVER M O �01' Christopher M.Cullinan, P.E. { -4_ Carpenter&Cross LLC CCullinan@CarpenterandCross.com 0�sst 150 W,9 /22/2023 5650 Blazer Parkway, Dublin.Ohio 43017 T 614 289-2977 www.CaronterandCross.com Fall Zone Letter S �� f1?CZd=rbc TOWN OF SOUTHOLD ZONING BOARD OF APPEALS Appeal No. � Yl SOUTHOLD, NEW YORK AFFIDAVIT OF In the Matter of the Application of: MAILINGS Elite Towers - Budd's Pond Marina, Inc., a/k/a Albertson's Marina (Name of Applicant/Owner) 61405 Main Road, Southold, NY 11971 SCTM No. 1000- 56-3-15 (Address of Property) (Section, Block& Lot) COUNTY OF SUFFOLK STATE OF NEW YORK I, ( ) Owner, ( X) Agent Colette Vaughan with an office at 666 Old Country Road, Ste. 901, Garden Cit *X�k1xXXX New York, being drily sworn, deposes and says that: On the 15th day of September , 2023, I personally mailed at the United States Post Office in Garden City_, New York, by CERTIFIED MAIL, RETURN RECEIPT REQUESTED, a true copy of the attached Legal Notice in Prepaid envelopes addressed to current property owners shown on the current assessment roll Verified from the official records on file with the (X) Assessors,or ( ) County Real Property Office, for every property which abuts and is across a public or private street, or vehicular right-of-way of record, surrounding the applicant's property. (Signature) Sworn to before me this L day of20 23 INDIA DECARMINE NOTARY PUBLIC-STATE OF NEW YORK a No.02DE5060491 otary Pu is Qualified in Suffolk County Za26 My Commission Expires 05-20 22 PLEASE list on the back of this Affidavit or on a sheet of paper, the lot numbers next to the owner names and addresses for which notices were mailed. All original USPS receipts and mailing confirmations to be submitted to the ZBA Office along with this form completed, signed and notarized. a 0 -7639 Budd's Pond Marina, Inc.,a/k/a Altertson's Marina,Wireless Cell Tower Application#7839 LIST OF RECIPIENTS(With S/B/L Indicated) .b oRIEC DOT LONG ISLAND RAILROAD CO. PERSON AUTHORIZED TO RECEIVE SERVICE ,gyp °5 93-02 SUTPHIN BLVD'#400 `n ' 'r��: £a�° (yam ` ?. �?"i° fE 'r_r.;$.e,®, •�swa JAMAICA, NY 11435 :::=' Certified Mail Fee ni 56-1-9.1 m $ J, �'tt = Extra Services&Fees(check box,add fee as appropr(ryf! TOWN OF SOUTHOLD ❑Return Receipt(hardcopy) $ _ © ❑Return Receipt(electronic) $ t Postm4 53095 ROUTE 25 C7 ❑Certified Mail Restricted Delivery $ �5 w U:)',Her I<�• PO BOX 1179 I3 []Adult Signature Required $ � [—]Adult Signature Restricted Delivery$ r✓ — �4• SOUTHOLD, NY 11971 r 3 Postage �l 56-1-10.1 m MAIN ROAD BROKERAGE II LLC m ANGELINA R. NORTON PO BOX 937 610 POND AVENUE rru SOUTHOLD, NY 11971 .__________________ 0 SOUTHOLD, NY 11971 56-4-1 56-1-11.11TIM ANGELINA R. NORTON U.S. Postal ervice LONG CREEK DRIVE CERTIFIED,MAIL®R -RECEIPT Y SOUTHOLD, NY 11971 P` 56-1-11.12 0 Certified Mail Fee ANGELINA R. NORTON m $ ;, .Al �" Extra Services&Fees check box,add fee as ro nate; 610 POND AVENUE ( app p >>�� ❑Return Receipt(hardcopy) $ SOUTHOLD, NY 11971 O ❑Return Receipt(electronic) $ I SPostmark I= [I Certified Mail Restricted Delivery $0 []Adult Signature sci r-3 E]Adult Signature Required $ .�,3 r 56-3-13.3 _. Adult Signature Restricted Delivery$ � v' Postage MAIN ROAD BROKERAGE INC. SUFFOLK COUNTY �4 �P � , PO BOX 937 m PERSON AUTHORIZED TO RECEIVE SERVICE SOUTHOLD, NY 11971 m 330 CENTER DRIVE 56-3-13.4 RIVERHEAD, NY 11901 ---_-____'___"_- 56-6-1.2 1 MAIN ROAD BROKERAGE II LLC "' '' PO BOX 937 SOUTHOLD, NY 11971 56-4-1 SUFFOLK COUNTY PERSON AUTHORIZED TO RECEIVE SERVICE 330 CENTER DRIVE RIVERHEAD, NY 11901 56-6-1.2 e • TM M ECE ■ ■ MAILP . 'EI ■ • o!estic�Maff&y ® e o RECEIPT'; .0 s. • irily Ln Mill"Mm o o L!7 b_ - ! ;��r'"�3 (t3€� r, •{� j .mom j . o o - - ,.,� �':;,jl i) 0 �-„•^ :,_s r.•:-: o r• �___» n ru Certified Mail Fee dtF M $ r 4�1 G� ni Certified Mail ee Extra Services$Fees(checkbox,add fee as appe rb eta) ~���°i m $ J',� ,✓• M ��'� ❑Return Receipt(hardcopy) $ 0 �J' X7„'44 �- Extra Services&Fees(check box,add lee as appropdaRB) C3 ❑Return Receipt(electronic) $ g t,> ❑Return Receipt(hardcopy) $ i Q ❑Certified Mail Restricted Delivery $ Ln ' V� i%stmark ❑Return Receipt(electronic) $ I - POsfmark• []Adult Signature Required $ r, 11 eke 0 ❑Certified Mail Restricted Delivery $ r O �7 n Here []Adult Signature Restricted Delivery$ �, W --- ❑Adult Signature Required $ ;e W f Postage 'ti..y .` [I Adult Signature Restricted Delivery$ "�;��. 00 s> "' M �SjrQ 0 Postage " M MAIN ROAD BROKERAGEINC. m Mm ANGELINA R. NORTON ru PO BOX 937 610 POND AVENUE o SOUTHOLD, NY 11971 rruu SOUTHOLD, NY 11971 C3 ------------------ 56-3-13.4 ------------------ r` 56-3-13.3 ----------- :.r r r, .r.•r. - Pidistial 86riviceTm U.S. ' • stal Service", CERTIFIED e . ■ CERTIFIED e o . ■ rn - ru Ln Lr► . i f�.w,; i.»,. ri 7,':,� r` � ' µ� Q ,UMU ., I Certified Mail Fee ti_:.+ '! Certified Mail Fee Extra Services&Fees(checkbox,add lee as eppmp{iate) u ,�- Extra Services$Fees(check box,add fee as❑ ' e - appropriate) Return Receipt(hardcopy) $ ❑Return Receipt(hardcopy) p $ N C3 ❑Return Receipt(electronic) $ F (� Postmark d [IReturnReceipt(electronic) $ r,' !.R Lark Certified Mail Restricted Delivery $ '�."'a „v"He � ❑Certified Mail Restricted Delivery re $ r/ Y•OStmark ice^ Adult Signature Required $ -"--^ CI -Here w. I ❑ g q ' ❑Adult Signature Required $ O. t (0 []Adult Signature Restricted Delivery$ - C3 El Adult Signature Restricted Delivery$ � 0 Postage Postage M m r:a_ c, mANGELINA R. NORTON ,J m ANGELINA R. NORTON 'm nj 2640 LONG CREEK DRIVE ru 610 POND AVENUE ru SOUTHOLD NY 11971 I }C3 SOUTHOLD, NY 11971 C3 1----------------- r`• 56-1-11.12 J 56-1-11.11 ------------------ Postal. _ ■ • nly cc o. Only VI Domestic • O � Ln .�s< ( ! u l✓.1 �� 1t".z ;m�-a ti�-��}r ��V-� ,�p i--`I if' I£ II 3b.� II 3'r�; Certified Mali Fee Certified Martj il Fee !m $ \� 1z... m $ Extra Services&Fees check box,add fee as �� �� I� Extra Services&Fees(check box,add fee as appropriate)','V C7, N ❑Return Recelpt(hardcopy) $ "'>y �` i- ❑Return Receipt(hardcopy) $ i t 1 Q ❑Return Receipt(electronic) $ Stmark1' Q ❑Return Receipt(electronic) $ ') tom''I 0 ❑Certified Meil Restricted Delivery $ -' ere ❑Certified Mail Restricted Dellve 9 r -Postmarrl'.-- ,, .' -1 O Delivery $ a•• Here Q []Adult Signature Required $ i ji;�. O ❑Adult Signature Required $ W fig,_ []Adult Signature Restricted Delivery$ []Adult Signature Restricted Delivery$ n'�^,� Dncf�nu M $ LONG ISLAND RAILROAD CO ",` ti m' TOWN OF SOUTHOLD r J i m rt PERSON AUTHORIZED TO RECEIVE SERVICE m 53095 ROUTE 25 $ 93-02 SUTPHIN BLVD,#400 ru I I ru, PO BOX 1179 JAMAICA NY 11435 ________________ 1 n-r ►tis 56-1-9.1 Z4- - o SOUTHOLD, NY 11971 ---•-.. .. 56-1-10.1 -------------------- I 10/6/23, 1:20 PM USPS.com@)-USPS Tracking@)Results USPS Tracking' FAQs > Tracking Number: Remove X 70223330000043260560 t L L C- Copy Add to Informed Delivery (https:Hinformeddelivery.usps.com/) Latest Update Your item was picked up at the post office at 9:56 am on September 20, 2023 in SOUTHOLD, NY 11971. Get More Out of USPS Tracking: m CD USPS Tracking Plus® a v n Delivered Delivered, Individual Picked Up at Post Office I SOUTHOLD, NY 11971 September 20, 2023, 9:56 am Available for Pickup SOUTHOLD 710 TRAVELER ST SOUTHOLD NY 11971-1000 M-F 0900-1700; SAT 0900-1300 'September 18, 2023, 6:07 pm Arrived at Post Office SOUTHOLD, NY 11971 September 18, 2023, 6:06 pm In Transit to Next Facility September 17, 2023 Departed USPS Regional Facility MID NY DISTRIBUTION CENTER September 16, 2023, 9:24 pm https://tools.usps.com/go/TrackConfirmAction?tRef=fullpage&tLc=2&text28777=&tLabels=70223330000043260560%2C 1/2 10/6/23, 1:20 PM USPS.com®-USPS T ig®Results Arrived at USPS Regional Facility MID NY DISTRIBUTION CENTER September 15, 2023, 9:42 pm � Hide Tracking History What Do USPS Tracking Statuses Mean? (https://faq.usps.com/s/article/Where-is-my-package) Text & Email Updates u USPS Tracking Plus® u Product Information u See Less Track Another Package Enter tracking or barcode numbers Need More Help? Contact USPS Tracking support for further assistance. FAQs https://tools.usps.com/go/TrackConfirmAction?tRef=fulipage&tLc=2&text28777=&tLabels=70223330000043260560%2C 2/2 10/6/23, 1:22 PM USPS.com@-USPS Tracking@ Results USPS Tracking° FAQs > Tracking Number: Remove X 70223330000043260553 SSC, ja,�, Copy Add to Informed Delivery (https://informeddelivery.usps.com/) Latest Update Your item was picked up at the post office at 9:56 am on September 20, 2023 in SOUTHOLD, NY 11971. Get More Out of USPS Tracking: -n CD USPS Tracking Plus® CL v Delivered Delivered, Individual Picked Up at Post Office SOUTHOLD, NY 11971 s September 20, 2023, 9:56 am `t 1 Available for Pickup' SOUTHOLD 710 TRAVELER ST SOUTHOLD NY 11971-1000 M-F 0900-1700; SAT 0900-1300 September 18, 2023, 6:07 pm Arrived at Post Office SOUTHOLD, NY 11971 September 18, 2023, 6:06 pm In Transit to Next Facility September 17, 2023 Departed USPS Regional Facility MID NY DISTRIBUTION CENTER September 16, 2023, 9:33 pm https://tools.usps.com/go/TrackConfirmAction?tRef=fullpage&tLc=2&text28777=&tLabels=70223330000043260553%2C 1/2 10/6/23, 1:22 PM USPS.com®-USPS 1 igO Results Arrived at USPS Regional Facility MID NY DISTRIBUTION CENTER September 15, 2023, 9:40 pm Hide Tracking History What Do USPS Tracking Statuses Mean? (https://faq.usps.com/s/article/Where-is-my-package) Text & Email Updates \ u USPS Tracking Plus@ u Product Information u See Less Track Another Package Enter tracking or barcode numbers Need More Help? Contact USPS Tracking support for further assistance. FAQs hftps://tools.usps.com/go/TrackConfirmAction?tRef=fulipage&tLc=2&text28777=&tLabels=70223330000043260553%2C 2/2 r i�3 aq,wm_W-7'' i a i ■ ■■ iii �°'. � �. COMPLETE • , . . .ELIVERY SENDER: o • '.?tl� 5B. gna re ■ Complete items 1,2,and 3. z ❑Agent ■ Print your name and address on the reverse ❑Addressee so that we can return the card to you. i ■ Attach this card to the back of the mailpiece, ceived by(Printed Name) C. Date of Delivery or on the front if space permits. r ---- - -- D. Is delivery address different from item 1? ❑Yes f' If YES,enter delivery address below: [I No ANGELINA R. NORTON 6POND / I 10 AVENUE SOUTHOLD, NY 11971 j 56-3-13.3 I 3. Service Type ❑Priority Mail Express® I III'I'I'I Ilii I'llll VIII IIIIIII�II�Ii I I'III III ❑Adult Signature ❑Registered Mailr ❑ R ❑Adult Signature Restricted Delivery Registered Mall Restricted 1 q.Gertified Mail® Delivery 9590 9402 7306 2028 8383 35 ❑Certified Mail Restricted Delivery ❑Signature ConfirmationT ❑Collect on Delivery ❑Signature Confirmation 2. Article Number(Transfer from service labeQ ! ❑Collect on Delivery Restricted Delivery Restricted Delivery t til iiliila Iii 1 it�I Ii !I❑tn1ured,Nlail iI iII I 1 1 1 Il 7022' 3 3i3 0 '0 0 0 0' 4 3 2 6 2 5 4 6 rre$500)�I Restricted Delivery PS Form 3811,July 2020 PSN 7530-02-000-9053 Domestic Return Receipt SENDER: COMPLETE THIS SECTION DELIVERY ■ Complete items 1,2,and 3. A. Signature l ■ Print your name and address on the reverse X ❑Agent ` so that we can return the card to you. ❑Addressee ■ Attach this card to the back of the mailpiece, B. Receive by(Pniffed Name) C. Date of Delivery or on the front if space permits. 1 AMA. f— --- - - --- -- - D. Is delivery address different from item 1? ❑Yes lANGELINA R. NORTON If YES,enter delivery address below: [3No ' 2640 LONG CREEK DRIVE / SOUTHOLD, NY 11971 s✓ I' 56-1-11.12 I 3. Service TypeQ Priority Mail Express® II 1111111 IIII ill l 11 Ii l l l I I II II it l 11 l 111 I I II III El Adult Signature Registered MailTM Adult Signature Restricted peiiVery• 1:1Registered Mail Restricted Certified Mail® Delivery 9590 9402 7306 2028 8383 42 11 Certified Mail.Restrlcted Delivery ❑Signature ConfirmationTM ❑Collect on,Delivery'. ❑Signature Confirmation 2. Article Number(Transfer from service/abeq ❑Collect I"biaiyery'Resteicted Delivery Restricted Delivery ^!^sured;Mail; _ I 11ured Mail Restricts '':'livery' I i 7022 33311' 0000 143'26` 053:9 I "ber.$500) 6 PS Form 3811,July 2020 PSN 7530-02-000-9053 X + Domestio%Return Receipt COMPLETE • ON DELIVERY SENDER' • • ■ Complete items 1,2,and 3. A. Signature I��� 1 Agent ■ Print your name and address on the reverse X C��I Addressee � so that we can return the card to you. ■ Attach this card to the back of the mailpiece, B. Receive P ed am) Ca too Delivery or on the front if space permits. ,t- nrtirlAAridressed to: D. Is delivery a ss diff f m item 1 ❑ as 1 i 11 If YES,enter delivery address below: L] o I SUFFOLK COUNTY �`/// PERSON AUTHORIZED TO RECEIVE SERVICE 330 CENTER DRIVE 1 RIVERHEAD, NY 11901 56-6-1.2 3. Service Type ❑Priority Mail Express® I Ilillllll'III 111111 VIII IIIIIIIIIIIIII VIII III ❑Adult Signature ❑Registered MaiITM ❑Ad�uult Signature Restricted Delivery ❑Registered Mail Restricted. dGrartifad Mail® Delivery 9590 9402 7306 2028 8383 04 ❑Certified Mail Restricted Delivery ❑Signature Confirmation ❑Collect on Delivery ❑Signature Confirmation ❑Collect on Delivery Restricted Delivery Restricted Delivery . ; 7 0 ---,F-,frnm service label) ❑Insured Mail 2 2 ;3 3 3 0 , 0 Q0 0 4 3 2 6 0;5 7 7 ; �i iid Mail Restricted Delivery, ) - Domestic Return Receipt PS Form 3811,July 2020 PSN 7530-02-000-9053 Vy. 1 y r � f �10' f J COMPLETE •N COMPLETE THIS SECTIONON DELIVERYI ■ Complete items 1,2,and 3. A. Signat re Agent ■ Print your name and address on the reverse X ❑Addressee so that we can return the card to you. i ■ Attach this card to the back of the mailpiece, (-calved (Print Name) C. Date of Delivery or on the front if space permits. - )9-133 l TOWN OF SOUTHOLD D. I delivery address different from item 1? ❑Yes If YES,enter delivery address below: ❑ No 53095 ROUTE 25 � I � I PO BOX 1179 i SOUTHOLD, NY 11971 56-1-10.1 II I IIIIII IIII I'f I1111I I I l l II II I'I II I I I IIII I III 3. Service Type ❑Priority red Express® 4 ❑Adult Signature O Registered Ma ilTM fl ❑ ult Signature Restricted Delivery ❑Registered Mall Retricted Certified Mail@ Delivery 9590 9402 7306 2028 8383 66 ❑Certified Mail Restricted Delivery ❑Signature Confirmation- ❑Collect on Delivery ❑Signature Confirmation 2. Article Number(Transfer from service label) ❑Collect ed mall ail Delivery Restricted Delivery Restricted Delivery - 7022 3330 0000 4326 0 515 ed Mail Restricted Delivery '$500) _ PS Form 3811,July 2020 PSN 7530-02-000-9053 Domestic Return Receipt Tif SECTION ON DELIVERY 'CUM ETE THI&,SECTION COMPLETE ,.ISP4 I ■ Complete items l,2,and 3. A. Signature ' [3 Agent ■ Print your name and address on the reverse X ❑Addressee so that we can return the Card to you. v B. Received by(Printed Name) C. Date of Delivery ■ Attach this card tathe back of the mailpiece, or on the front if space permits. - -r D. Is delivery address different from item 1? 11 Yes LONG ISLAND RAILROAD CO. if YES,enter delivery address below: ❑No RECEIVE SERVICE AUTHORIZED TO RECIi PERSON ` I 93-02 SUTPHIN BLVD,#400 v/ JAMAICA, NY 11435 56-1-9.1 -_ 3. Service Type ❑Priority Mail Express@ Iilllllll IIII Illlll IIII IIIIIIIEIIIIIII III I III ❑Adult Signature ❑Registered MailT" V❑Q�dult Signature Restricted Delivery E3 Registered Mail Restricted Certified Mail@ Delivery 9590 9402 7306 2028 8422 57 ❑Certified Mail Restricted Delivery ❑Signature ConfirmationTM ❑Collect on Delivery ❑Signature Confirmation f ❑Collect on Delivery Restricted Delivery Restricted Delivery 2. Article Number(Transfer from service label) ured Mail. : : : : :: : : r ured MalI RestFlcted Delivery 7022 :333 ; Q�I]� :x}3126 05(]8 'ar:$5oo): : . : : :: : : PS Form 3811,July 2020 PSN 7530-02-000-9053 Domestic Return Receipt ; 'I COMPLETE •N COMPLETE THIS SECTIONON DELIVERY ■ Complete items 1,2,and 3. A. Signature ■ Print your name and address on the reverseE3Agent so that we can return the card to you. X lb, ❑Addressee ■ Attach this card to the back of the mailpiece, B. (-calved by(Pante me) C. Date of Delivery I i or on the front if space permits. D. Is delivery address different from item 1? ❑Yes ANGELINA R. NORTON If YES,enter delivery address below: ❑ No 610 POND AVENUE SOUTHOLD, NY 11971 i ---- 56-1-11.11- —---- J i 11I IIII'I I'll I'I I1111I I I I I II11II I II I I IIII I I III 11 AdulSignature 0 Registered MallTM t i Signature Restricted Delivery ElRegl Registered Mail Restricted 9590 9402 7306 2028 8383 59 J 7.G`ertified Mail@ Delivery ❑Certified Mail Restricted Delivery ❑Signature Confirmationrm O Collect on Delivery ❑Signature Confirmation 2. Article Number(Transfer from service lab,-n ❑Collect on Delivery Restricted Delivery Restricted Delivery d Mail 7022 3330 0000 4326 0522 fired Mail Restricted Delivery —0r$500) PS Form 3811,July 2020 PSN 7530-02-000-9053 Domestic Return Receipt TOWN OF SOUTHOLD ZONING BOARD OF APPEALS SOUTHOLD, NEW YORK AFFIDAVIT OF In the Matter of the Application of: POSTING l f V t'e T' WC9z4& (-P WA!?- t i- 5/0 6 H vJ i26i.E�S LC.G (Name of Applicants) S d 011i o L.(J COUNTY OF SUFFOLK STATE OF NEW YORK residing at 51 SP�d SY IS 1. P ,New York, being duly sworn, depose and say that: I am the ( ) Owner or (4 Agent for owner of the subject property On the 2©-10 day of 5W'�"660- , 2023, I personally placed the Town's Official Poster on subject property located at: 6 4 05 A&*,AJ eto So stt(oLA l NY l l°ll The poster shall be prominently displayed on the premises facing each public or private street which the property involved in the application or petition abuts, giving notice of the application or petition, the nature of the approval sought thereby and the time and place of the public hearing thereon. The sign shall be setback not more than 10 feet from the property line. The sign shall be displayed for a period of not less than seven days immediately preceding the date of the public hearin of �$� 5�{ ZAZ3 (10/,�/2.--2) (Owner/Ag6t Signature) �� , 20� J� � Sworn to before me th' �� ay of (Notary Pu lc Mary Ann Howard / y Notary Public,State of New York No.01H06192860,Suffolk County Commission Expires Sept.2,20L l BOARD MEMBERS Southold Town Hall Leslie Kanes Weisman, Chairperson ��OF $U(/j�o 53095 Main Road•P.O. Box 1179 Patricia Acampora �� 1p Southold,NY 11971-0959 Eric Dantes [ c Office Location: Robert Lehnert, Jr. Town Annex/First Floor Nicholas Planamento �l� ^��Q 54375 Main Road(at Youngs Avenue) OW N$� Southold,NY 11971 http://southoldtownny.gov ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631) 765-1809 August 22, 2023 Mark Terry,Assistant Town Planning Director LWRP Coordinator Planning Board Office Town of Southold Town Hall Annex Southold,NY 11971 Re: ZBA File Ref. No. # 7839 ' Dear Mark: We have received an application to construct a new wireless telecommunications facility. A copy of the Building Inspector's Notice of Disapproval under Chapter 280 (Zoning Code), and survey map, project description form, are attached for your reference. Your written evaluation with recommendations for this proposal, as required under the Code procedures of LWRP Section 268-51) is requested within 30 days of receipt of this letter. Thank you. Very truly yours, Leslie K. Weisman Chairperson By: `'"N�'l� Encls Survey/Site Plan Jeremy K. McKeon Date : 6/15/2023 BOARD MEMBERS Southold Town Hall Leslie Kanes Weisman, Chairperson ��0� $UU�yO53095 Main Road•P.O. Box 1179 Patricia Acampora 1p Southold,NY 11971-0959 Eric Dantes #[ Office Location: Robert Lehnert,Jr. Town Annex/First Floor Nicholas Planamento 54375 Main Road(at Youngs Avenue) COU Southold,NY 11971 http://southoldtownny.gov ZONING BOARD OF APPEALS TOWN OF SOUTHOLD August 16, 2023 Tel. (631) 765-1809 Ms. Sarah Lansdale,-Director Suffolk County Department of Planning P.O. Box 6100 Hauppauge, NY 11788-0099 Dear Ms. Lansdale: Please find enclosed the following application with related documents for review pursuant to Article XIV of the Suffolk County Administrative Code: ZBA File : # 7839 Budd's Pond Marina Inc. Action Requested : To construct a new wireless telecommunications facility Within 500 feet of: (X) State or County Road (X) Waterway (Bay, Sound, or Estuary) ( ) Boundary of Existing or Proposed County, State, Federal land (X) Boundary of Agricultural District ( ) Boundary of any Village or Town Within one (1) mile (5,280 feet) of: ( ) Boundary of any airport If any other information is needed, please do not hesitate to call us. Thank you. Very truly yours, Leslie K. Weisman ZBA C peponl, By: Survey/Site Plan Jeremy K. McKeon Date : 6/15/23 �� BOARD MEMBERS Southold Town Hall Leslie Kanes Weisman, Chairperson ®� $®��� 53095 Main Road• P.O. Box 1179 Patricia Acampora ®� ®�® Southold,NY 11971-0959 Eric Dantes [ Office Location: Robert Lehnert,Jr. @ Town Annex/First Floor Nicholas Planamento y® 54375 Main Road(at Youngs Avenue) COUNTYSouthold,NY 11971 http://southoldtownny.gov ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631)765-1809 MEMO RECEIVED TO: Planning Board AUG 16 2423 I FROM: Leslie K. Weisman, ZBA Chairperson Southold TownPlanning Board DATE: August 16, 2023 SUBJECT: Request for Comments ZBA# 7839 Budd's Pond Marina Inc. The ZBA is reviewing the following application. Enclosed are copies of Building Department's Notice of Disapproval, ZBA application, and current map on file. Your review and comments are requested at this time. The file is available for review of additional documentation at your convenience for reference if needed. Applicant: Budd's Pond Marina Inc. Tax # Zone District: 56-3-15 ZBA #: 7839 Hearing Date: October 5, 2023 Code Section: Article XIII Section 280-53 and Bulk Schedule Date of Stamped Site Plan : 6/15/2023 Preparer of Survey Jeremy K. McKeon Thank you. (Enc.) OFFICE LOCATION: MAILING ADDRESS: Town Hall Annex �of S®(��Iy® P.O.Box 1179 54375 State Road Route 25 ems® I® Southold,NY 11971 (cor.Main Rd. &Youngs Ave.) Southold, NY CA 41C Telephone: 631 765-1809 http://southoldtow=y.gov ZONING BOARD OF APPEALS Town of Southold December 27, 2023 Gregory Alvarez,Esq. Amato Law Group 666 Old Country Road, Ste 901 Garden City,NY 11530 3 RE: ZBA Appeal #789, Budd's Pond Marina 61405 Main Road, Southold SCTM No. 1000-56-3-15 Dear Mr. Alvarez; Transmitted for your records is a copy of the Board's December 21, 2023, Findings, Deliberations and Determination, the original of which were filed with the Town Clerk regarding the above variance application. Before commencing any construction activities, a building permit is necessary. Please be sure to submit an application along with a copy of the attached determination to the Building Department and the Planning Department. Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured,and/or a subdivision map has not been filed with the Suffolk County Clerk,within three (3)years from the date such variance was granted. The Board of Appeals may, upon written request prior to the date of expiration,grant an extension not to exceed three (3) consecutive one(1)year terms. IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO ENSURE COMPLIANCE WITH THE CODE REQUIRED TIME FRAME DESCRIBED HEREIN. Failure to comply in a timely manner may result in the denial by the Building Department of a Certificate of Occupancy, nullify the approved variance relief, and require a new variance application with public hearing before the Board of Appeals If you have any questions, please call the office. Sincerely, � I Kim E. Fuentes Board Assistant Encl. cc: Building Department Planning Department OFFICE LOCATION: MAILING ADDRESS: Town Hall Annex ��OF SU(/ P.O. Box 1179 54375 State Route 25 OTyOI Southold, NY 11971 (cor.Main Rd. &Youngs Ave.) Q Southold, NY Telephone: 631 765-1938 www.southoldtownny.gov couffm PLANNING BOARD OFFICE TOWN OF SOUTHOLD MEMORANDUM RECEIVED 0CT .0 4 2023 To: Leslie Weisman, ZBA Chairperson of Appeals Members of the Zoning Board of Appeals Zoning Board ._.- From: Donald J. Wilcenski, Planning Board Chairman Members of the Planning Board Date: October 4, 2023 Re: ZBA#7839,Budd's Pond Marina 61405 Main Road, Southold SCTM#1000-56.-3-15 The Planning Board has reviewed your request for comments regarding the above-referenced application, and is requesting more time to provide substantive remarks for your consideration. The Planning Board is currently waiting to receive the report from our technical consultant for this wireless facility proposal. In addition, the Planning Board plans to take Lead Agency under SEQRA and will be coordinating with the ZBA as an involved agency. If you have any questions or require,additional information,please do not hesitate to contact the Planning Office. cc: James Squicciarini, Deputy Town Attorney SEE SEC.N0.052. . MATCH � .... .. < t. 11.17FOR tt Ra:L,No.•�' �' 45.5A �) Y��'' SEE SE9,No. (COUNOFSUfFOLK :`� ' a DEVELOPMENTRIGHTS) li i 052-0&OOt •• ' n./� \ �:. Hasm.O.Ik �\': Fend TOWN OF t _ (COUNTY OF SUFFOLK r- 9u.g s tb•`V� g, �' SOUTHOLD _ DEVELOPMENT RIGHTS) -`'' ;' 'f \ ' 5.1 COUN 43 . 73A TY OF SUFFOLK m � 3. 22A ,6 TSOOVisAN(aO.O 9£ C4, TH " i 1.3A TO•MJ OF P —Ly SOUiHOLD`\p 171 zAs f i`ver. � 10P�c� -�. .-p°TDA 4.2 10.1 1� TOWN OF i'i.ti a°', 1',•��^' S4? r,rJ�.!; �j_.-'' P v SOUTHOLD j✓„ �aN. :2`; J„a.ie+'” .,�°97•`e�c/'`.f moi,Q• flr 3.8A -"'c��% ,..'�l�i'•� ,T;. �0!�h J'•• (COUN7YOFSUFFOLK `, : 1�•` ,gt� DEVELOP1dENTRIGHTSj- /• "\i 51\\ •jy^.`�'.ti .� •` i\ ; ��0. i;,a.✓�, 1° , I .�,,,tili-i i`. .,_0,�coa`$,,a.,', h. a,y�F: 5Z.a�»fes, r✓��i pccyo�`., ,8'Sy,�• J tib z.a�pSt m`. '•\ EDF :a5e�=,: \ o` 11.11 i�3 cOo M° a @„},,6 3• 5 �u� ,t*' -^.fir/y ,-.ril< o 5' .\. ��I• ,� {COUNTY OF SUFFOLK .:.H, .' .!.n�•\tq r'tlj .A . �,�' ,t DEVELOPMEWRIGY.rsj - `, y .''' ..\£;° 'v 1 \ 14 .aA(a) • ,s• - S ly`�`. r�gPlcl .\a •y' �'u 'c �1�"+� . 11,10 11.6�,)$ �, 4�•• y,.s' ,% <, ,�.n$. ,'+„�'•�;-.. 10.9A ? 11.12. '\ - •.'. .a, �'F� '� 1.7A(c) ate ,a (COUNNOF SUFFOLK ' / _`. ,1^'Y/+ .r 22 / l\ DEVFtOPAeNT RIGHTS) w ea , \ ,,Op\ .�1'• ` 11.2 '!: .�\• 4 /� 12N. ;#•,. _dg. - .+'..r' :,e5`"t4 O i',.' 2.3A(e) 13 ter-- skeD� 12.1 ,^3?i'3.OA(e) f. COUNT/ i^ 2O,9A(c) $¢ ;,/x, OF SUFFOLK, �;~ E TOWN OF SOUTHOLD / .'ia/.:°`'~✓✓ ) ,5 �'a m'2\4. ° % .,� / 0.43 p�;�,' ..4�. ..Pa_.. rr`"` ��tiP %r' s,r-�.ou?: 0 3� :• Budd's Pond �;f 3i •i' i '��� ,,r\ •$pr ..•/`�:.\,g0�' .� i 10'fU� .`'L Nl+xmwTexu^t�) ��.,,..,, _ -, . ;i , ol 93 POS Q�sP ,,/�(i✓�'” �. � ti�p F^'� >� .a' / ,�, I,z:/"¢1s�y=�;a�t,C,m,a,�; t f ' � ''la'r'd' `gym\ 1� i� /-"� �•' ' „c/1 ,e .,i \+. ��.' A�ii O a l/ P'f,, pp1- ,�•.'.'/•. \,.0�3,ro`n(f':"',t;.15 13.1 '' 28 ai . 14 CANyL-stn kyr 2.5A(c) F .. 8-� v� 'Y `:�,� a COUNTY OF SUFFOLK © N NOT' 5-(,— A Ep 0— eal Property Tax Service.Agency MA1NTE`oNcr ALTM w E DISTRISUnON OF AM I L_ 300 Center Drir,Po1rrLad.AY 11901 SUFFOLK COUNTY Ti- \/ ��J m tW c zw aao S, WITEAIHOUT WRITTENPERIY P ^ 3- 13 3 f-,rL Feet R PROJECT TEAM GENERAL NOTES THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE CLIENT REPRESENTATIVE �- MAINTENANCE.THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE; NO SANITARY �.I COMPANY; ELITE TOWERS L.P. , SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED. r`F o ADDRESS: 1 S. DURKEE LANE C111 -1• CITY,STATE,ZIP: E. PATCHOGUE, NY 11772 CONTACT: TANYA NEGRON PHONE: (516)410-8730 - N APPLICABLE BUILDING CODES & STANDARDS E-MAIL: TANYA.NEGRON@ELITE-TOWERS.COM ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE : 1`tit C3 I C� E 1 '. 1! a f SITE ACQUISITION ` FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO y COMPANY: ELITE TOWERS L.P. 1 `�, �,.., r- �, } PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES. ADDRESS: I S. DURKEE LANE ( ' ► �r�,_J In IrIi' �� �� L I .�' ( I�I C ,..+1r ) I C — CITY,STATE,ZIP: E. PATCHOGUE, NY 11772 I. 2020 BUILDING CODE OF NEW YORK STATE(IBC 2018 WITH AMENDMENTS) 'p 7 CONTACT: TANYA NEGRON 516 410-8730 j.C,(y(t 2. NATIONAL ELECTRICAL CODE NFPA 70-17 E L I T T'���+�'�.I• S I P PHONE: ( ) t"Tri,ss Comm,U Cit+a-s infrastv::rure Enos E-MAIL: TANYA.NEGRON@ELITE-TOWERS.COM 3. 2020 FIRE CODE OF NEW YORK STATE(IFC 2018 WITH AMENDMENTS) ENGINEER LITIT"I 4. LIGHTNING PROTECTION CODE NFPA 780-2017 COMPANY: AZIMUTH ENGINEERING P.C. SON S. AMERICAN CONCRETE INSTITUTE 318-14 - ADDRESS: 695 ROUTE 46 WEST, SUITE 300 CITY, STATE, ZIP: FAIRFIELD, NJ 07004 6. AMERICAN INSTITUTE OF STEEL CONSTRUCTION 15TH EDITION .;; CONTACT' JEREMY MCKEON PHONE: 973-970-0068 E-MAIL: JMCKEON@AZIMUTHEG.COM I-SOU7. EIAlTIA-222 REVISION H T 8. TIA 607 FOR GROUNDING APPLICANT/LESSEE • „t ---- 9. INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS 81 COMPANY: ELITE TOWERS L.P. LON ' .....LESS ADDRESS: I S. DURKEE LANE 10. IEEE C2 LATEST EDITION : .; CITY,STATE,ZIP: E. PATCHOGUE, NY 11772 -ro 11. TELCORDIA GR-1275 12.ANSI T1.31 I CO-APPILICANTsoir Tr LS IT A..#4 A.04 0 4 COMPANY: NEW YORK SMSA LIMITED PARTNERSHIP d/b/a VERIZON WIRELESS PROJECT DESCRIPTION/SCOPE OF WORK ADDRESS: 4 CENTEROCK ROAD CITY,STATE,ZIP: WEST NYACK, NY 10994 THIS PROJECT WILL BE COMPRISED OF: CO-APPLICANT ELITE TOWERS: INSTALLATION OF NEW EQUIPMENT COMPOUND, V-0" HIGH CHAIN LINK FENCE, 150' PROTECT YOURSELF COMPANY: SOUTHOLD FIRE DISTRICT , ALL STATES REOUIRE NOTIFICATION OF CONCEALMENT TOWER, MESA CABINET, ELECTRIC METER BANK, ELECTRIC TRANSFORMER, EXCAVATORS, DESIGNERS, OR ANr PEPSON rTHO F1 DIS"" rl" PREPARING TO DISTURB THE EARTH'S ADDRESS: 55135 MAIN ROAD STEEL&CONCRETE BOLLARDS, LANDSCAPING&SHRUBBERY SURFACE ANYWHERE IN ANY STATE CITY,STATE,ZIP: SOUTHOLD,NY 10994 Know Maes below. • NEW 70'-0"x 35'-0"EQUIPMENT COMPOUND WITH V-0"CHAIN LINK FENCE. = I Call before you dig. • NEW 150'CONCEALMENT TOWER= I FOH STATE SPECIFIC DIRECT PHONE NUMBERS • MESA CABINET= I VISIT: WWW.CALL811.COM SHEET INDEX ELECTRIC METER BANK= I • ELECTRIC TRANSFORMER= I SCALE DRAWN by: CHLCKED BY: • STEEL&CONCRETE BOLLARDS =4 AS SHOWN WAS p SHEET NUMBER DESCRIPTION • NEW TREES,SHRUBBERY, LANDSCAPING =T.B.D. Z-01 TITLE SHEET SOUTHOLD NY FIRE DEPARTMENT -D 0 Z-02 SITE PLAN&NOTES 61405 • NEW FIRE DISTRICT EQUIPMENT CABINET= I 0 12/23/21 ISSUED FOR FILING WPK JWS • NEW FIRE DISTRICT ANTENNA- I Z-03 BULK TABLE • NEW FIRE DISTRICT PTP= I E 10/15/21 REVISED PER COMMENTS GJB JWS Z-04 ZONING INFORMATION VERIZON WIRELESS: D 05/12/21 REVISED PER COMMENTS WAS JWS 1 SOUr-"LHO 1 1971 INSTALLATION OF NEW 2'-0'0 CONCRETE PIERS, 20'-0"x 10'-0"STEEL EQUIPMENT PLATFORM, C 05/03/21 REVISED PER COMMENTS WAS JWS Z-05 200' RADIUS PLAN EQUIPMENT CABINET, BAT-r"FY CABINET,TELCO CABINET PPALBERT XURINE v kww R1 WIR NAM LD LD R1 TvIAIN AD LD NY C CABINET,WORK LIGHTS, B 04/29/21 REVISED PER COMMENTS WAS JWS Z-O6 VICINITY P E ' � DISCONNECT SWIT77NTCH, CARIE BRIDGE, PANEL ANTENNAS, RRH'S&DIPLEXERS. Z-07' 200'&500'PROPERTY OWNERS LIST Z-08. COMPOUND PLANLK A 04/06/21 ISSUED FOR REVIEW WAS JWS Z-09 EQUIPMENT PLAN L-TNNEW 2'-0"0 CONCRETE PIERS=6 SUV'FO CO-r ) NEW 20'-0"x 10'-0"STEEL EQUIPMENT PLATFORM = I REV DATE DESCRIPTION DRAWN CHECKED NEW EQUIPMENT CABINET'= I Z-10 ANTENNA PLANS&ANTENNA SCHEDULE NEW BATTERY CABINET= I SIT""Z-II ELEVATION NEW TELCO CABINET= I NEW PPC CABINET= I .. Z-12 CONSTRUCTION DETAILS- I NEW WORK LIGHTS=2 y/,�@� N-� °"`' I�"" `'.� , Z-131 CONSTRUCTION DETAILS-2 NEW DISCONNECT SWITCH = I NEW CABLE BRIDGE = I I Z-14 EQUIPMENT DETAILS- I ' " NEW PANEL ANTENNAS=2 PER SECTOR, 6 TOTALTA * a LIU Z-15 EQUIPMENT DETAILS-2150 I TA Do I NEW RRH-2 PER SECTOR, 6 TOTAL h� CONC ILI JL L NEW DIPLEXERS=4 PER SECTOR, 12 TOTAL <� Z-16 FIRE DISTRICT EQUIPMENT cF�s,FOP o Cq1 Z-17 2007 INSURANCE FLOOD INSURANCE MAP R0F S AERIAL MAP VICINITY MAP �REM1� McKEON 6NEW YORK ICENSED PROFESSIONAL ENGINEER- LICENSE NUMBER:095374-1 f Y i ' AREA OF WORK IT IS A VIOLATION of LAW FOR ANY PERSON, ,+ W �-E UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE RESPONSIBLE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. It .e} AREA OF WORK ,her y R .$ kF y .. ;4� SITE INFORMATION : P 9A'v, "`q "^•R h.i , ,✓'r ?W{+�� �y SY.'fi ;"M .,P S y '} Rk'111'I SITE NO,• ALBERTSON MARINE SITE INFORMATION t . . . x 61405 MAIN ROAD PROPERTY/TOWER WER OWNER x .r NAME: BUDD'S POND MARINA INC. �'..�: ' SOUTHOLD, NY 11971 ;. _ � '� x� ;, Albertson P��arine Inc ADDRESS: 61405 MAIN ROAD , ti` P�,I dealer SUFFOLK COUNTY CITY,STATE,ZIP: SOUTHOLD NY. 11971 F �j DISTRICT: 1000 SITE TYPE: SECTION 56.00r � � - ' �` 150'-0" CONCEALMENT POLE r f., ' BLOCK/LOT: 3/15AK y � r LATITUDE: 41.076024t COPYRIGHT©2021,AZIMUTH ENGINEERING P.C.,LLC ALL r. .. . .' * RIGHTS RESERVED LONGITUDE: -72.406034 THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CLPTIFIED. THIS C LAT./LONG.TYPE: NAD 83 DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED OR RELIED UPON FOR ANY OT-1ER PURPOSE *'; "" " w' f WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH AREA OF CONSTRUCTION: PROPOSED CONCEALMENT POLE& EQUIPMENT COMPOUND = a' r `J"3 ENGINEER;KG P C, LLC. ZONING/JURISDICTION: TOWN OF SOUTHOLD Lj SHEET TITLE: ZONING DISTRICT: M-11 MARINE 11A T Z CURRENT USE/PROPOSED USE: UNMANNED TELECOMMUNICATION FACILITY # i TITLE SHEET R.' p 25f O A HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN " k. SHEE 1 NUMBER: HABITATION. HANDICAPPED ACCESS NOT REQUIRED. W ' Z-01 0 W Q Q Ln N cn Q) Qj BOTTOM OF sLopE wETLq� J LINE ✓ETLq���s PROPOSED 70'-0" x 35'-0" EQUIPMENT 0 9.6 LONG COMPOUND (SEE SHEET Z-08) ND I JIieless Cann,micatixis ln`rastru tore Experts --_ 3.0 W -1 L 0 2.7 o q 0 9.1 STN, HDbVL. r, ` (N69°0 '20" TRAC`�� 8. � Z 2.3 ►- E� Z BOT. O „ 7® O + W F sLor TF4.54 59 41-7 55 4.5 5 0 GRAVEL SL 8.9 +� a ,, �. TF6.14 - OPE \ o O o w _ 1540 ± T \1j _ U '"' U8.6 4.2 4: . 6 TO NEAREST BUILDING N ADJACENT PROPERTY of SL 4.3 .� `�' u' Z 6.1 STN. HD L U O 8.6 g ' • Z U 4.6 8.3 TO FENCE C f Yrru \moil. ►" 3:8 OMPOUND Ri \ 5 3.4 --- 1 � ,\ ISI' 4 TF .38 93 4.7 TO CONCEALMENT POLES 4.4 4.3 __ 3.9 I NOTES: 4.5 3.5 1LOCATION AND ORIENTATION 0F PROPOSED EQUIPMENT A D ANTENNAS PENDING +, z _ STRUCTURAL ANALYSIS. o O �:1r_ - ;'' � h� N '-.. � R �� w ,T0-) PROTECT YOURSELF 61.9' 2. MOUNT ALL ANTENNAS, COAX, SURGE ARRESTORS, RRH'S, ETC. IN ACCORDANCE m �- ALL STATES REOURE NOTIFICATION STN of o EHCAVAT0IS, DESIGNERS, OR ANY PERSON fM, PREPARING TO DISTURB THE EPRTH'S SURFACE ANYWHERE IN ANY STATE cc WITH STRUCTURAL A - ` 4.5 4 - -- °max Know whafsbelow. ANALYSIS. > 90 2 4.4 Call before you dig. z \ FF4,58 \ FOR STATE SPECIFIC DIRECT PHONE NUMEERS 3. TRUE NORTH BASED ON DOODLE MAPS. -- I VISIT: WWW.CALL811 .COP1 4.6 tiF m R I SCALE: DRAWN BY. -HECI,ED Bt 4. NOT ALL EXISTING INFORMATION SHOWN FOR CLARITY. = J I FsT�N gS0; AS SHOWN WAS JKM ' LLJ �I rFRS 5. SITE PLAN BASED ON SITE SURVEY BY AMERICAN ENGINEERING & LAND = o FCT�O ---- ---- -- ---- ---- SURVEYING P.C. SIGNED BY STEPHEN E. RAVN P.E. L.S. LICENSE #49664 & m , TO F 47-0 ± 3 g �1/�RO ---- ---- ---- ---- ---- DATED 10/24/18. 0 4.7 t O I NCE COMPOUND O Q� 0 12/23/21 ISSUED FOR FILING WPK JWS I E 10/15/21 REVISED PER COMMENTS GJB JWS 6. FINAL UTILITY DESIGNS SHALL BE CONFIRMED WITH UTILITY COMPANIES. 86-0p'+', Z W TO CQ U D 05/12/21 REVISED PER COMMENTS WAS JWS NCEALM `NT POLE C 05/03/21 REVISED PER COMMENTS WAS WS 7. THE PROPOSED USE IS FOR TEL AND IS NOT INTENDED FOR GI;AVE� O - J P Y OCCUPANCY. THEREFORE POTABLE WATER, SANITARY -j- °- HILI 1 STOR 1PERMANENT EMLO EE OCC N \ B 04/29/21 REVISED PER COMMENTS WAS WS SEWERS AND ADDITIONAL ON-SITE PARKING ARE NOT REQUIRED. pAo METAL BUILDING Z ��` A 04/06/21 ISSUED FOR REVIEW WAS JWS z TF4.56 I +I w A MONTH FOR Q - X61405 O I o REV DATE DESCRIPTION DRAWN CHECKED 8. THE FACILITY SHALL BE VISITED ON THE AVERAGE OF ONCE MON 0 ' MONITORED FROM A REMOTE I BY BY A,I TE A CE AND SHALL BE CONTINUOUSLYM N I 4.4 4.7 +� a.3 M N NN N FACILITY FOR BOTH FIRE AND INTRUSION. 4 3 OZ o O 4.1 U Lc U w \ ' ` 9. ALL MATERIALS, WORKMANSHIP AND CONSTRUCTION FOR THE SITE IMPROVEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH: ~ W z Gv 4.0 z L1► W A. CURRENT PREVAILING MUNICIPAL AND/OR STATE SPECIFICATIONS, STANDARDS AND REQUIREMENTS. I No. OC3 4.4 ., sF�PROFES B. CURRENT PREVAILING UTILITY COMPANY AUTHORITY SPECIFICATIONS, �P STANDARDS AND REQUIREMENTS. r I 0.H.0. 4 `'`' FF4. 3 OF4.64 JOE ' K MCKEON `� 4.25 C w 4.24 90,3' - 10. CONTRACTOR SHALL CONTACT "NEW YORK UNDERGROUND PLANT LOCATION 4.44' P���T. o NEW YO LICENSED PROFESSIONAL v 4.71 SERVICE" AT 1 -800-962-7962, AND LOCATE ALL EXISTING UTILITIES WITHIN PLNl. 4 72 ENGINEER-LICENSE NUMBER:095374-I z � 4 ��^d 40.7' 4. o THE AREA OF WORK PRIOR TO THE START OF ANY EXCAVATION. LO 4.21 �t uLO N�ESSATFVIO ARiorJ OTIN A FOR THE PERSON, 1 1 . CONTRACTOR SHALL COORDINATE AND COMPLY WITH EXISTING UTILITY �J ECTIOH of THE REsPoNSIeAE LICER THIS PROFESSIONAL AL ENGINEER, TO ALTER THIS DOCUf,4ErdT. COMPANIES REQUIREMENTS. CONC. °W ASPH. 3.78TF3.71 SITE INFORMATION : 12. UNDERGROUND ENCROACHMENTS, IF ANY, ARE NOT SHOWN. _ - _ - ,� 3.92 - i U 4 4.03 3.88 3.6� 3. SITE NO: ALBERTSON MARINE 13. ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES ARE TO BE RESTORED TO ,� E.A. 39 x.37 E.A.. I PRE-CONSTRUCTION CONDITIONS. 3.51 S 7®2 6 ' 7�y 1�/ 2 0 . 0 0 ' TF3�0 61405 MAIN ROAD 14. THERE ARE NO WATER MAINS, SANITARY SEWERS, DRY WELLS, GROUND WATER (S58°31 '00"'N) DYL DYL SOUTHOLD, NY 11971 RECHARGE BASINS, OR DETENTION BASINS PROPOSED FOR THE PROPERTY. 4.33 4.26 4.10 3.90 3.98 4.03 SUFFOLK COUNTY 15. NO SIGNALS, SIGNS OR TRAFFIC CHANNELIZATION OR PUBLIC ROAD IMPROVEMENTS ARE PROPOSED. SITE TYPE: A f\ �O � C� . 150',0" CONCEALMENT POLE 16. THERE ARE NO PROPERTY DEDICATIONS PROPOSED. 17. NO TEMPORARY OFFICES OR STRUCTURES ARE PROPOSED FOR THE SITE. COPYRIGHT©2021,AZIMiJTH ENGINEERING P.C.,LLC ALL 18. THESE DRAWINGS ARE PROVIDED FOR ZONING APPROVAL. CONSTRUCTION LEVEL RIGHTS RESERVED THIS DRAWING A"JD A''_L THE INFORMATION CONTAINED HEREIN IS 6' AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE DRAWINGS WILL BE DEVELOPED SUBSEQUENT TO THE APPROVAL OF THESE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DRAWINGS. UNDERGROUND SERVICE ALERT - NEW YORK 81 1 DIWITHIOUTETHE EXPRESS W ITTEN COfNSENT OR AZIMUTHS wUTILITY NOTIFICATION CENTER OF NEW YORK p EPIGINEERING F.G., LLC. 19. SITE PLAN BASED ON SITE SURVEY BY AMERICAN ENGINEERING & LAND (800) 272-4480 , z SURVEYING P.C. SIGNED BY STEPHEN E. RAVN P.E. L.S. LICENSE #49664 & WWW.NEWYORK-81 ICOM SHEET TITLE: Q DATED 10/24/18. �\ Know what's beIOW. SITE PLAN &NOTES CALL 2 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION Call before you dig. L 2 If SHEET rIuMsFR: 1 SITE PLANLLJ GRAPHIC AET ALE 2I 10' 0 20' 40' "_ " Z-�2 _J _ SCALE 112" 0-0 OR 11"xl7 DRAWINGS Q Q 0 �d CN SULK REQUIREMENTS FOR ZONE M-II (MARINE II) cn ° DESCRIPTION REOUIRED EXCTING PROPOSED COMMENTS MINIMUM LOT DIMENSIONS AREA 80,000 SQ FT 41 ,346 SQ FT NO CHANCE NON—COMPLIANT 4 «.` WIDTH 150 FEET 200.00 FEET NO CHANGE COMPLIES � �� r � .� ����'�1�� ITsVI DEPTH 150 FEET 189.79 FEET NO CHANCE COMPLIES dfe tst Comrr,,n,tatrv)e,InYashu:ture Expe-Is MINIMUM YARDS 35 FEET ±29.4 FEET FRONT 174'± (TOWER) COMPLIES MINIMUM YARDS SIDE 9-5 FEET 40.7 FEET 86'± (TOWER) COMPLIES i REAR 25 FEET 61 .9 FEET 30'± (TOWER) COMPLIES , BOTH SIDES 50 FEET 102.6 FEET 199'± (TOWER) COMPLIES „ MINIMUM YARDS SOUTHOLD , SIDE 25 FEET 40.7 FEET 47'± (COMPOUND) COMPLIES 7 REAR 25 FEET 61 .9 FEET 8'± ' -- -- (COMPOUND) NON—COMPLIANT BOTH SIDES 50 FEET 102.6 FEET 127'± (COMPOUND) COMPLIES "'.:; LANDSCAPE AREA 20% MAX 0% 4.43% COMPLIES zwd:':.•;_ =h=-- may``' MAXIMUM LOT COVERAGE 30% 26.2% 5.8% (NEW) 32% TOTAL) NON—COMPLIANT 1w 01� REQUIREMENTS OF CHAPTER 280 ZONING ARTICLE XVII WIRELESS COMMUNICATIONS FACILITY „ DESCRIPTION COMMENTS 1 . MAXIMUM HEIGHT PER WIRELESS ORDINANCE: 80' VARIANCE (� OR WAIVER PROTECT YOURSELF REQUIRED ALL STATES REOUIRE NOTIFICATION OF ® EXCAVATORS, DESIGNERS, OR Allti PERSON 2. MINIMUM DISTANCE OF ALL WIRELESS EOUIPMENT TO ADJACENT RESIDENTIAL PROPERTY LINES OR VARIANCE OR ' PREFAB"'� TSURFACE ANYWH=RE N DIRE IN THE EARTHS ANY STATE STREETS SHALL BE NO LESS THAN 500 FEET. WAIVER REQUIRED Inowwhaesbelow. Call before you dig. 3. FALL ZONES. AN ANTENNA SUPPORT STRUCTURE MUST INCLUDE AN AREA SURROUNDING IT THAT FOR STATE SPECIFIC DIRECT PHONE NUMBERS IS FREE OF OTHER STRUCTURES AND AREAS WHERE PEOPLE CONGREGATE, EXCEPT THE BASE VISIT: WWW.CALL811.COM EQUIPPAENT, WITH A RADIUS EQUAL TO A DISTANCE OF TWO TIMES THE HEIGHT OF THE STRUCTURE. A SMALLER FALL ZONE MAY BE ALLOWED IF SUPPORTED Bl' A REPORT SUBMITTED S ALE: DRAWN BY: �HEcr_L, Br: BY A QUALIFIED STRUCTURAL ENGINEER. THE STRUCTURAL ENGINEER'S REPORT SHALE BE VARIANCE OR WAIVER AS SHOWN WAS JKM SUBMITTED TO AND REVIEWED BY THE PLANNING BOARD AND CORRO3CRATED BY AN REQUIRED INDEPENDENT CONSULTANT HIRED BY THE TOWN THAT DEMONSTRATES -HAT A SMALLER FALL ---- ---- --- ---- ---- ZONE IS APPROPRIATE AND SAFE. THE FALL ZONE OF AN ANTENNA SUPPORT STRUCTURE MUST NOT INCLUDE AREAS WHERE PEOPLE CONGREGATE, AND MUST BE CLEAR OF ALL STRUCTURES EXCEPT THE BASE STATION EQUIPMENT. 0 12/23/21 ISSUED FOR FILING WPK JWS 4. MINIMUM LOT SIZE: IN ACCORDANCE WITH THE BOLI: I IN 0 < PIP _1L gg" 0 nl.,� N 4 Co .401- 0 CN .7 S 11 ViN" OFt" T 0i" -E �7 ur�nefftlport 01� V, U T E NC-3 HNJ E E P I N�' Sa 'qe 131vd 3 .......... IT ToWERSL E��vl ess communitawns IP*astwctvjI Expos F T ell Aq X 0 C A, 400 HamletCenter -0 Th SITE L 01 1 F- LOCATION 71 03 zoning NF ", I I Ax O\e ON M Ojlt.�, ZONING IQ d Uj F_j Z N x AC 0 IifPOUNTY0FISO ,F& -�rl A A k� IN ? W� -I C., - I I .- " �,:, 4! j__ ell AHD verizonl/ _j N.7 voi B PROTECT YOURSELF J �x HB ,It ALL STATES REQUIRE NOTIFICATION OF 2001 E X CAVATORS, DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN ANY STATE L X, below. HD Know whaf s Cal I before you dig. FOR STATE SPECIFIC DIRECT PHONE NUMBERS VISIT: WWW.CAL-LSII.COM RADIUS LINE LB gggg ,gmeI,, S: 1,r,�VM ni WA OWN JKM 6 AS SH S Ll ILE ---- ---- ---- ---- ---- LIO ---- ---- ---- L 0,;, N INI-: 0 12/23/21 ISSUED FOR FILING WPK JWS dg 'j M1 E 10/15/21 REVISED PER COMMENTS GjB jWS or=- jj :2,3 >OU D 05/12/21 REVISED PER C01111-1— V) m M 11 C 05/03/21 REVISED PER COMMENTS WAS g� ico WS �jo B 04/29/21 REVISED PER COMMENIS OAS JVV3 0 0.25 0.5 11 F R-40 A 04/06/21 ISSUED FOR REVIEW WAS JWS III Mile IT - V. . ,[911111U x WK F, Jt,� 71 DRAVVN jL_t1tk_Rtj REV DATE DESCRIPTION 4 Vi BY BY _jI R-80 j� ' ",'%I JV RO 1—67- n I co r RR ,tK Cr Llj A ! ...... b -A Anc X, Or j.,, 4 0. 09 Yr, 'A' 4 0 McK�ON RE NE� ED PROFESSIONAL MCENS n F ENGINEER LICENSE NUMBER:095374-1 - 17% 3, A V Tk IF- IT IS A VIOLATION OF LAW FOR ANY PERSON, 0� UNLESS THEY ARE ACTING UNDER THE DIRECTION '411 41 4) OF THE RESPONSIBLE LICENSED PROFESSIONAL N Bay ENDNEER, TO ALTER THIS DOCUMENT, N" b SITE ! NFORMATION , 4 e i 411 -A! L t' ALBERTSON MARINE SITE NO, Ile C/ 0 AM_ ;,j V 4')" 61405 MAIN ROAD t (7111 _281I S- V U X Y SOUTHOLD, NY 11971 JZ. Cr V- SUFFOLK COUNTY I.9f I k F SITE TYPE: V_ `sl�, ............... 'ONCEALMENT POLE 150'-0" C .............. COPYRIGHT 9)Z021,AZIMUTH ENGINEERING P.C.,LLC ALL RIGHTS RESERVED THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN I',-, AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE Map Prepared by WORK WAS CONTRACTED OR TO WHOM IT CERTIFIED, THIS NOTE: R COPIED, U EIS D 0 D AWING MAY NOT BE RE S D, ISCLOSED, Town of Southold Geographic Information System DISTRIBUTED OR RELIED UPON FOR ANY OTHER PURPOSE > WITH OUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH L-1-1 ENGINEERING P.C., LLC. CLI 1 . PARTIAL ZONING MAP IS BASED ON ZONING July 29, 2016 CL N MAP PREPARED BY THE TOWN OF SOUTHOLD Suffolk County Real Property Tax Service Agency GEOGRAPHIC INFORMATION SYSTEM DATED AREIS and Tax Map Copyright 2016, < County of Suffolk, NY ZONING INFORMATION I& 07/09/16. 0 Ln SHEET NUMBER: GRAPHIC SCALE GRAPHIC S Z-04 (IN FEET) CALE N.T.S. I PNRML TAX MAP N*T.S. 2 ZONING MAP (IN FEET) Q 0 Ln Ln N �q O N kr� tib -Y" M U xII {'-Se4"u" 'N E__-1%4C3' 1NF_ER1NG 7C U ITE 10 re,' Utsm�r � ' Wiaar�€�t�ans 4 3fe�fitntCkLer e } 3 y Icz SOUT v 00 verizo• N C�' ® PROTECT YOURSELF ALL STATES REQUIRE NOTIFICATION OF XC o EAVATORS, DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH'S ,�..^ SURFACE ANYWHERE IN ANY STATE Know wNes below. Call before you dig. FOR STATE SPECIFIC DIRECT PHONE NUMBERS 'r VISIT: WWW.CALL811.COM s \LE, DRAWN BY: CHECKED BY: r AS SHOWN WAS JKM 00i FR ON P OFFSET ---- ---- ---- ---- Y IBM 0 12/23/21 ISSUED FOR FILING WPK JWS E 10/15/21 REVISED PER COMMENTS GJB JWS D 05/12/21 REVISED PER COMMENTS WAS JWS C 05/03/21 REVISED PER COMMENTS WAS JWS B 04/29/21 REVISED PER COMMENTS WAS JWS FFSET A 04/06/21 ISSUED FOR REVIEW WAS JWS NOWa, DRAWN CHECKED FR�I`1 �R�PE REV DATE DESCRIPTION BY BY PROPERTY LINE00 �F ya s �a 'Py.. ip ^+�� '1 rn-° . v e cc � No 0953 . . u 044 FESS IDEM, K McKEON W NEW YORK`LICENSED PROFESSIONAL z ENGINEER- LICENSE NUMBER:095374-1 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION W OF THE RESPONSIBLE LICENSED PROFESSIONAL LJL. rV40 ENGINEER, TO ALTER THIS DOCUMENT. LL . 00 SITE INFORMATION N °- SITE NO: ALBERTSON MARINE EE 0 oC � 4 61 05 MAIN ROAD � LL SOUTHOLD, NY 11971 SUFFOLK COUNTY SITE TYPE- 150'-0" CONCEALMENT POLE COPYRIGHT©2021,AZIMUTH ENGINEERING P.C.,LLC ALL RIGHTS RESERVED O THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN LY Y THE THE " :. w WORKOWASDCONORRACTEDUSE NOR 70 WHOM ARTS COERTFH DM THIS O DRAWING MAY NOT BE COPIED, REUSED; DISCLOSED, DISTRIBUTED OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH Ld ENGINEERING P.C., LLC. O N W I i I I _z 200' RADIUS PLAN z 0 S EEI NUMBER: I 200' RADIUS PLAN GRAPHIC N.T.S. Z-05 — -- - (IN FEET) J I Q 1 n 0 10 N O N N r a i U z�3 l N G I N E 'R I N G RC. fl 6 ELITE Wneless O mmunicAons 1nnmtructvre E;(pwls N 00 �Y PROPOSED 150' ::L, CONCEALMENT POLE verizon■ PROTECT YOURSELF ALL STATES REQUIRE NOTIFICATION OF o EHCAVATORS, DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN ANY STATE Know what's below. Call before you dig. FOR STATE SPECIFIC DIRECT PHONE NUMBERS R VISIT: WW1,t,LCALL811 COM 300 INTERSEGT�ON DRAWN BY: CHECKED BY AS SHOWN WAS JKM A 0 12/23/21 ISSUED FOR FILING WPK JWS r E 10/15/21 REVISED PER COMMENTS GJB JWS LLJ Z O�Q ��' D 05/12/21 REVISED PER COMMENTS WAS JWS N /O C 05/03/21 REVISED PER COMMENTS WAS JWS B 04/29/21 REVISED PER COMMENTS WAS JWS ~ A 04/06/21 ISSUED FOR REVIEW WAS JWS W � g, DRAWN CHECKED LJREV DATE DESCRIPTIONev) eY BY 4 ' O v O b 4 � F• .53'1 . I JEREMY McKEON NEW r ENGINEER YORK LICENSED LIC LICENSENUMBER: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION �{ OF THE RESPONSIBLE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. LEGEND SITE INFORMATION , R-80,PARKS & RECREATION M-II-MARINE II SITE NO: ALBERTSON MARINE 61.405 MAIN ROAD SOUTHOLD, NY 11971 SUFFOLK COUNTY SITE TYPE: --- -- 150'-0" CONCEALMENT POLE R-40 RESIDENTIAL COPYRIGHT©2021,AZIMUTH ENGINEERING P.C.,LLC ALL RIGHTS RESERVED U� THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN i`_� AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE TO NOTE: WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. THIS O DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH AERIAL IMAGE BASED ON ENGINEERING P.C., LLC. N GOGGLE MAPS DATA 2019 LLj SHEET TITLE: z VICINITY PLAN z o TF CLT NUMBER: m 1 VICINITY PLAN GRAPHICSCALE N.T.S. (IN FEET) 05 Z-06 Q Q LF, „ . 0 0 N U i s - - District Section Block Lot Owner Owner's Address EuTE TONVERS LP '^JIiF!P55 4,gfIt1'.I f:','.x'3fl'T'1`if fi'dCtfLIT YUf'EX(5F`t5 1000 56 1 4.2 Scott & Pauline Carter 1605 Mill Path, Southold, NY 11971 �- 1000 56 1 10.1 Town of Southold 2205 Mill Path, Southold, NY 11971 1000 56 1 11 ,2 Angela Norton 610 Pond Avenue, Southold, NY 1971 UTA OL, 1000 56 1 11 .6 Angela Norton 610 Pond Avenue, Southold, NY 1971 01 1000 56 1 11 .11 Angela Norton 610 Pond Avenue, Southold, NY 1971 In 1000 56 1 11 .12 Angela Norton 610 Pond Avenue, Southold, NY 1971 1000 56 3 13.3 Angela Norton 61025 Route 25, Southold, NY 11971 1000 56 3 14 New York Telephone Co. 60975 Route 25, Southold, NY 11971 PROTECT YOUR`-ELF ALL STATES REQUIRE NOTIFICATION OF EXCAVATORS, DESIGNERS, OR ANY PERSOt; PREPARING TO DISTUFB THE EARTH'S e SURFACE ANYWHERE IN ANY STATE 1000 56 3 15 Budds Pond Marine Inc. 61405 Route 25, Southold, NY 11971 Know whafsbelow. Call before you dig, FOR STATE SPECIFIC DIRECT PHONE NUi.1BERS 1000 56 3 1 Main Road Brokerage LI, LLC 61505 Route 25, Southold, NY 11971 VISIT: WWW.CALL81l.COM SCALE: DkAWN Bi- LHECkEU D . 1000 56 3 2 Emmanuel & Toula Leodis 61575 Route 25, Southold, NY 11971 AS SHOWN WAS JKM ---- ---- ---- ---- ---- 1000 56 3 3 Emmanuel & TouSa Leodis 61625 Route 25, Southold, NY 11971 ---- ---- ---- ---- ---- 0 12/23/21 ISSUED FOR FILING WPK JWS 1000 56 3 4 Town of Southold 61725 Route 25, Southold, NY 11971 E 10/15/21 REVISED PER COMMENTS GJB JWS D 05/12/21 REVISED PER COMMENTS WAS JWS 1000 56 3 5 62375 Main Road LLC 61825 Route 25, Southold, NY 11971 C 05/03/21 REVISED PER COMMENTS WAS JWS B 04/29/21 REVISED PER COMMENTS WAS JWS 1000 56 3 6 62375 Main Road LLC 62375 Route 25, Southold, NY 11971 A 04/06/21 ISSUED FOR REVIEW WAS Jws REV DATE DESCRIPTION DRAWN CHECKED BY BY 1000 56 5 7 Margaret Dato 445 Budds Pond Road, Southold, NY 11971 Ecka Grando �.�e� �y.• 1000 56 5 8 545 Budds Pond Road, Southold, NY 11971 1000 56 5 9 Suffolk County 64 Budds Pond Road, Southold, NY 11971q D 1000 56 5 10 Marcia Jurinovic 745 Budds Pond Road, Southold, NY 11971 `'s� �o. 0953�a 1000 56 5 11 Jonathan Tibett 845 Budds Pond Road, Southold, NY 119716R!MY cKEON NEW RK ICENSED PROFESSIONAL 1000 56 5 16 Patrick Redmond 750 Budds Pond Road, Southold, NY 11971 ENGINEER- LICENSE NUMBER:095374-1 IT IS A VIOLATIOIJ OF LAW FOR ANY PERSON, 1000 56 5 17 Jean & John Weber 590 Budds Pond Road, Southold, NY 11971 OLESS THEY ARE ACTING UNDER THE DI D! OF THE RESPOfJSIBLE LICENSCD PROFESSIONALIONAL ENGINEER, TO ALTER THIS DOCUA1ENT. 1000 56 6 1 .1 Eli Green & Dalton Route 25, Southold, NY 11971 SITE N TO R M A TI 0 N : 1000 56 6 1 .2 Suffolk County 61330 Route 25, Southold, NY 11971 SITE NO: ALBERTSON MARINE 1000 56 6 2.2 Budds Pond Marina Inc. 61500 Route 25, Southold, NY 11971 61405 MAIN ROAD SOUTHOLD, NY 11971 1000 56 6 3.4 61600 Main Road LLC 61600 Route 25, Southold, NY 11971 SUFFOLK COUNTY SITE TYPE: 150'-0" CONCEALMENT POLE COPYRIGHT©2021,AZIMUTH ENGINEERING P.C.,LLC ALL RIGHTS RESERVED THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORT WAS CONTRACTED OR TO WHOA IT IS CERTIFIED. THIS CD DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH LTJ ENGINEERING P.C., LLC. f� LLi SHEET TITLE: z Q 200' &500' PROPERTY OWNERS LIST z 0 �HEE1 I'JUP4BE�: Z-07 1 PROPERTY OWNERS LIST OF Q c z o NOTES: i. NOT ALL EXISTING INFORMATION SHOWN FOR CLARITY. T o 2. COMPOUND PLAN BASED ON SITE SURVEY BY AMERICAN ENGINEERING & LAND SURVEYING P.C. SIGNED PROPOSED 4'-0" x 6'-0" CONCRETE EQUIPMENT PAD FOR }„ BY STEPHEN E. RAVN P.E. L.S. LICENSE NO. & DATED 10/24/18) FIRE DISTRICT EQUIPMENT (SEE DETAIL 4, SHEET Z-13) �J 3. FINAL LOCATION OF EQUIPMENT TO BE CONFIRMED WITH OWNER & ELITE PRIOR TO CONSTRUCTION. PROPOSED TREE (TYP OF 34±) N 4. LOCATION 7 INSTALLATION OF EQUIPMENT TO BE IN ACCORDANCE WITH THE STRUCTURAL ANALYSIS. (EMERALD GREEN ARBORVITAE V-0" TALL MIN.) TOWER DESIGN TO BE BY OTHERS. PROPOSED FIRE DISTRICT EQUIPMENT PLANTED IN STAGER PATTERN TO CREATE MAXIMUM CONCEALMENT BY 5. CONTRACTOR SHALL CONFIRM ALL EXISTING CONDITIONS PRIOR TO THE START OF WORK. CABINET ON 4'-0" x 6'-0" CONCRETE ( ELITE) rF s EQUIPMENT PAD (SEE SHEET Z-16) (SEE DETAIL 9, SHEET Z-12) V O L CT PROPOSED MESA CABINET (BY ELITE) ELITf Tov. r,.RS IT PROPOSED PAD MOUNTED IVl+elessCom..n,an�natianslnfrasknactureExDels TRANSFORMER BY ELITE -,v `�� // V l �\ 1r — `�` I SOUTHOLD h ° ° 1 PROPOSED POWER CONDUIT 4 z 1.� ROUTED UNDERGROUND FROM TRANSFORMER TO UTILITY FRAME (SEE DETAIL I, SHEET Z-12) ,'4PROPOSED FIRE DISTRICT CABLE BRIDGE i, 5 10'-0" A.G.L. (SEE DETAIL 4, SHEET Z-14) \ PROPOSED VERIZON WIRELESS UTILITY METER MOUNTED IN hti OPEN SOCKET (BY ELITE) I \ PROTECT YF)IIRSELF DISTUGB THE EARTH'S ALL STATES REQUIRE NOTIFICATION OF + PREFARI C, TO e EXCSURF°APE DEYWI-FRE. INO ANY STgTE ANY ERSOP! FUTURE CARRIER FUTURE CARRIER EQUIPMENT AREA--\ EQUIPMENT AREA Know what's below. A Call before you dig. W— FOR STATE SPECIFIC DIRECT PHONE NUMBERS VISIT: WWW.CALL811.COM I � GALL. ---]DRAWN BY CHECKED ti Y: PROPOSED MULTI METER-METER AS SHOWN WAS JKM _J u J / �, PACK WITH DISCONNECT (BY ELITE) PROPOSED FIRE DISTRICT CABLES ROUTED ON w PROPOSED 12'-0" WIDE ACCESS ---- ---- ---- ---- ---- / ° PROPOSED VERIZON WIRELESS 7/8"0 COAX CABLES � � - �� PROPOSED CABLE BRIDGE FROM FIRE DISTRICT ' L GATE (TYP OF 2 x 6'-0") (BY ELITE) 0 12/23/21 ISSUED FOR FILING WPK )WS o ROUTED ON PROPOSED CABLE BRIDGE TO TOWER EQUIPMENT TO PROPOSED TOWER TYP OF I �\ --� / � I ( ) / (SEE DETAIL I, SHEET Z-13) E 10/15/21 REVISED PER COMMENTS GJB )w5 w , (TYP OF 4 PER SECTOR, 12 TOTAL) Ln `1 \ Lv \ D 05/12/21 REVISED PER COMMENTS WAS JWS `n v' PROPOSED VERIZON ANTENNAS & EQUIPMENT C 05/03/21 REVISED PER COMMENTS WAS )WS -(BY VERIZON WIRELESS) WITHIN PROPOSED f- B 04/29/21 REVISED PER COMMENTS WAS )WS CONCEALMENT POLE (SEE SHEET Z-09) A 04/06/21 ISSUED FOR REVIEW WAS WS 0) O \ 1 \ I DRAWN CHECKED W � REV DATE DESCRIPTION BY BY I I PROPOSED 150' MULTI-SECTION 1 I Z-11 I I MULTI-SIDED RADOME - w ,, _o BY ELITE) ) CONCEALMENT TOWER LLJ E �> �^ I PROPOSED 70 0 x 35'-0" c? v (2,450 SQ. FT.) EQUIPMENTS ° I I COMPOUND (BY ELITE) / FUTURE CARRIER w J I EQUIPMENT AREA , i I r �l 0 ' EREM K MCKEON ° NEW YORK LICENSED PROFESSIONAL ENGINEER-LICENSE NUMBER:095374-1 E T E T E E E T E_0 ®-T E E T E - T - E IT IS A VIOLATION OF LAW FOR ANY PERSON, h1r\ UNLESS THEY ARE ACTING UNDER THE DIRECTION vvOF THE RESPONSIBLE LICENSED PROFESSIOfJAL / 70 1-011 ° ENGINEER, TO ALTER THIS DOCUMENT. PROPOSED 6'-0" HIGH BLACK CHAIN LINK FENCE (BY ELITE) 1� \ SITE INFORMATION : (SEE DETAIL 1, SHEET Z-13) l �� LJ SITE NO: ALBERTSON MARINE PROPOSED VERIZON WIRELESS UNDERGROUND POWER & TELCO PROPOSED VERIZON WIRELESS 10'-0" x 20'-0" STEEL PLATFORM CONDUIT (BY VERIZON WIRELESS) ROUTED FROM METER RACK & (BY VERIZON WIRELESS) WITH 42" TALL HANDRAIL & 8'-6" TALL MESA CABINET TO PROPOSED PPC & TELCO CABINET ON 61405 MAIN ROAD STEEL CANOPY(200SQ. FT.) IN A 10'-0" x 20'-0" LEASE AREA (200 SQ. FT.) PROPOSED EQUIPMENT PLATFORM (SEE DETAIL I & 2, SHEET Z-12) Li SOUTHOLD, NY 11971 (SEE SHEET Z-09) 1 SUFFOLK COUNTY EXISTING BUILDING-, - SITE TYPE: W� 150'-0" CONCEALMENT POLE COPYRIGHT©20 ENGINEERING P. LC ALL 21,AZIMUTH ENGINEER C. L RIGHTS RESERVED OTHIS DRAWING 4ND ALL THE INFOFMATION CONTAINED HEREIN IS AUTHORIZE[ FOR USE ONLY BY THE PARTY FOR WHOM THE PROPOSED VERIZON WIRELESS UNDERGROUND WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. THIS o POWER & TELCO CONDUIT ROUTED FROM UTILITY DISTRIBUTED DRAWING OR RELIED UPON COPIED, REUSED, OTHER PURPOSE w POLE TO TRANSFORMER & MESA CABINET WITHOUT THE EN GINEERINGTENC CONSENT OF AZIMUT" 0 J LL; SHEET TITLE: z COMPOUND PLAN z 0 4 0 4 g SKEET NUMBER: r/ LLJ1 COMPOUND PLAN GRAPHICSCALE z 2 SCALE: 1/4"= 1'-0"FOR 22"x34"DRAWINGS Z-08 (IN FEET) SCALE: 1/8"= 1'-0"FOR 11"x17"DRAWINGS Q z Q O O r`- E N PROPOSED FIRE DISTRICT CABLES ROUTED ON � IBRPROPOSED CABLE IDGE FROM FIRE DISTRICT EQUIPMENT TO PROPOSED TOWER (TYP OF I) 1 PROPOSED FIRE DISTRICT F7 NJ C; I 1\1 €--,I" .°G",. P FUTURE CARRIER CABLE BRIDGE 10-0„ A.G.L. `r EQUIPMENT AREA PROPOSED 150' MULTI-SECTION _ MULTI-SIDED RADOME (SEE DETAIL 4, SHEET Z-14) CONCEALMENT TOWER (BY ELITE) EL1T1- "O",ERS LT' O �O t"Jiie!e55 Comit+t8liois In`r35trvture,Expf-t5 �a SOUTHOLD ' % • . PROPOSED VERIZON WIRELESS 24"0 CONCRETE � \� PIER (TYP OF 6) (SEE DETAIL 4, SHEET Z-14) \ PROPOSED VERIZON WIRELESS GPS UNIT '• MOUNTED 2'-0" ABOVE PROPOSED CANOPY— le U PROPOSED VERIZON WIRELESS (TYP OF 4) (SEE DETAIL S, SHEET Z-15) \ / STEEL CANOPY (ABOVE) `�. PROPOSED VERIZON WIRELESS DUAL BAND RRH UNIT (TYP \\ ® PFOTECT YOURSELF ALL STATES RE�JUIRE NOTIFICATIrN Of OF 2 PER SECTOR, 6 TOTAL) (SEE DETAIL 2, SHEET Z-14) & ExPPEPA°.Rs'TO IDISTU\RHENEAPTHS°J PROPOSED VERIZON WIRELESS WORK LIGHT DIPLEXER (TYP OF 3 PER SECTOR, 09 TOTAL) (SEE DETAIL 6, �\ ` SURFACE ANYWHERE: IN ANY STATE (TYP OF 2) (SEE DETAIL 8, SHEET Z-12) SHEET Z-15) FOR MOUNTING (SEE DETAIL 2, SHEET Z-15) `� Knowwhat'sbelow. /I \ Call before you dig. 1 FOR STATE SPECIFIC DIRECT PHONE NUMBERS VISIT. JJWW.CALL°11.COM PROPOSED VERIZON PROPOSED VERIZON WIRELESS / / bCALL: DRAWN Br HE LED Br. WIRELESS BATTERY CABINET EQUIPMENT CABINET / AS SHOWN WAS JKM (SEE DETAIL I, SHEET Z-15) (SEE DETAIL I, SHEET Z-15) L ---- ---- ---- ---- ---- / O - O �/ ---- ---- -- ---- ---- t 0 12/23/21 ISSUED FOR FILING WPK )WS - ( �► O-_001 1 E � I -I I- � l I I- FH -RRH RRH RRH BRIDGE (SEE DETAIL 4, SHEET Z-14) D 05/12/21 REVISED PER COMMENTS WAS JWs PROPOSED VERIZON WIRELESS \ /DISCONNECT SWITCH MOUNTED PROPOSED VERIZON WIRELESS 7/8"Q� COAX CABLESC 05/03/21 REVISED PER COMMENTS was )ws 7�O PROPOSED H-FRAME B 04/29/21 REVISED PER COMMENTS WAS JWS i I, III ROUTED ON PROPOSED CABLE BRIDGE TO TOWER \\ A 04/06/21 ISSUED FOR REVIEW WAS JWS (TYP OF 4 PER SECTOR, 12 TOTAL) DRAWN CHECKED \ \ REV DATE DESCRIPTION BY BY -- — — 2 I - � � i I I --- -- —- a II i' All C 2SF No 095 C i it _ �pROFE! 17 II, ✓ V (`a .. I l /�RE 1 K McKEON� NEW YORK LICENSED PROFESSIONAL ENGINEER-LICENSE NUMBER:095374-1 j o _ X IT IS A VIOLATION OF LAW FOR ANY PERSON, M UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE RESPONSIBLE LICEIISED PROFESSIONAL \ — — ENGINEER., TO ALTER THIS DOCUMENT. I� SITE INFORMATION : - _ I ,\ � � � � - SITE NO: ALBERTSON MARINE PROPOSED VERIZON WIRELESS UNDERGROUND -- � � _ POWER & TELCO CONDUIT ROUTED FROM UTILITY _ — — POLE TO TRANSFORMER & MESA CABINET 61405 MAIN ROAD ' \/ (SEE DETAIL I & 2, SHEET Z-12) SOUTHOLD, NY 11971 0 -- SUFFOLK COUNTY 20'-0"± ; SITE TYPE: L- L % L 150'-0" CONCEALMENT POLE PROPOSED VERIZON / WIRELESS 42" TALL HANDRAILPROPOSED VERIZON WIRELESS WORK LIGHT / T T T \� 0—T T T T T COPYRIGHT©2021,AZIMUTH ENGINEERING P.C.,LLC ALL RIGHTS RESERVED GE E E E -- E E E E E E E THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN! IS (TYP OF 2) (SEE DETAIL 8, SHEET Z-12) / AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK. WAS CONTRACTED OR TO WHOM IT IS CERTIFIED, THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED OR RELIED UPON FOR ANY OTHER PUPPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH LLJ / ENGINEERING P.0, LLC. 0 i N Lei / SHEET TITLE: T PROPOSED VERIZON WIRELESS POWER & TELCO CABINETS MOUNTED ON PROPOSED HANDRAIL EQUIPMENT PLAN z 0 2 0 2 SHEE I WMBER: z I EQUIPMENT PLAN GRAPHIC SCALE s i s i " = r ” " " L J SCALE:3/4" 1 0 FOR 22 x34 DRAWINGS -09 m (IN FEET) __j - SCALE:3/8"= V-0"FOR 11"x17"DRAWINGS Q 0 PROPOSED VERIZON WIRELESS ANTENNA PROPOSED VERIZON WIRELESS ANTENNA '"r T` o MOUNTED WITHIN CONCEALMENT POLE MOUNTED WITHIN CONCEALMENT POLE s. (TYP OF 2 PER SECTOR, 6 TOTAL) (TYP OF 2 PER SECTOR, 6 TOTAL) o ` (SEE ANTENNA SCHEDULE ON THIS SHEET) ` (SEE ANTENNA SCHEDULE ON THIS SHEET) ko PROPOSED CONCEALMENT POLE ANTENNA �' � PROPOSED CONCEALMENT POLE ANTENNAPROPOSED DIPLEXER (TYP OF 4 PER SECTOR�p 3 ,MOUNT (COMMSCOPE PART NO. MTC37319) y MOUNT (COMMSCOPE PART NO. MTC37319) X12 TOTAL) (SEE DETAIL 6, SHEET Z-15) (TYP OF 2 PER SECTOR, 4 TOTAL) `t�`O (TYP OF 2 PER SECTOR, 4 TOTAL) � (SEE DETAIL 5, SHEET Z-15) G� 0 (SEE DETAIL 5, SHEET Z-15) y ti\ PROPOSED 40" DIA. \ ® MULTI-SECTION-MULTI-SIDED PROPOSED 40" DIA. � � PROPOSED 40" DIA. Q. � 'CO 'C/ RADOME CONCEALMENT POLE `-` � MULTI-SECTION-MULTI-SIDED SSG � MULTI-SECTION-MULTI-SIDED SSG ,�� �.. RADOME CONCEALMENT POLE/ % �Q�Pp���v RADOME CONCEALMENT POLE � / \ �Q�P ��� / \�� L -fI MVERS LP Pi P \ rlTeless C•omm,mr atiai�,tri astru:Wre Expe•ts 01 CI ` PROPOSED 6110 % PROPOSED 6110 � � \ � MAIN PIPE MAST \ MAINZ PIPE MAST o \ AI A2 SOUTHOLD B I B2 \ PROPOSED VERIZON WIRELESS ANTENNA PROPOSED VERIZON WIRELESS ANTENNA P oS REQ YOURSELF ALL STP TES REQUIRE NOT'FICA TION OF MOUNTED WITHIN CONCEALMENT POLE MOUNTED WITHIN CONCEALMENT POLE EXCAVATORS, DESIGNERS, DR ANY PERSON I � '� � PREPARING 6 TO DISTURB THE EARTH'S PROPOSED 11O MAIN PIPE MAST SURFACE ANY IN ANY STATE (TYP OF 2 PER SECTOR, 6 TOTAL) (TYP OF 2 PER SECTOR, 6 TOTAL) Know whaesbelow. (SEE ANTENNA SCHEDULE ON THIS SHEET) (SEE ANTENNA SCHEDULE ON THIS SHEET) Call before you dig. FOP, STATE SPECIFIC DIPCCT PHONE NUMBERS PROPOSED VERIZON WIRELESS ANTENNA i PROPOSED VERIZON WIRELESS ANTENNA VISIT: wwln.cALL81.coM �-/ MOUNTED WITHIN CONCEALMENT POLE �-� MOUNTED WITHIN CONCEALMENT POLE 'GALE: DRAWN E r I,HLI,KED E f: Oi,�`Z' TYP OF 2 PER SECTOR, A01/1 AS SHOWN WAS KM G/J ( 6 TOTAL) G�J (TYP OF 2 PER SECTOR, 6 TOTAL) ) mac-3��` (SEE ANTENNA SCHEDULE ON THIS SHEET) '��` (SEE ANTENNA SCHEDULE ON THIS SHEET) ---- ---- ---- ---- ---- 0 12/23/21 ISSUED FOR FILING WPK JWS E 10/15/21 REVISED PER COMMENTS GJB JWS D 05/12/21 REVISED PER COMMENTS WAS JWS C 05/03/21 REVISED PER COMMENTS WAS JWS B 04/29/21 REVISED PER COMMENTS WAS JWS A 04/06/21 ISSUED FOR REVIEW WAS JWS REV DATE DESCRIPTION DRAWN CHECKED BY BY 1 VERIZON CLUSTER 1 ANTENNA PLAN @ 147'-6" A.G.L. GRAPHICSCALELE N.T.S. 2 VERIZON CLUSTER 2 ANTENNA PLAN @ 142'-8" A.G.L. GRA(HIFCEETALE N.T.S. 3 VERIZON DIPLEXER PLAN BELOW ANTENNAS G�(RVFEETALE N.T.S. •f /Vo. 0953 �pR FESS ,j/ E<REM-/K MCKEON NEW YORK LICENSED PROFESSIONAL TScIlED k ENGINEER- LICENSE NUMBER:095374-1 IT IS A VIOLATION OF LAW FOR ANY P\SON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE RESPONSIBLE LICENSED PROFESSIONAL AND RRH CONFIGURATION ENGINEER, TO ALTER T PROPOSED ANTENNA AHIS DOCUMENT. ANTENNA RRH`S ON SITE N Toy,M A TI OI\� : PROPOSED ANTENNA ANTENNA HEIGHT WIDTH DEPTH WEIGHT FACE AREA ANTENNA ANT. CL. EQUIPMENT SITE NO.- ALBERTSON MARINE SECTOR QUANTITY CONFIGURATION STATUS (IN) (IN) (IN) Obs) (S.F.) AZIMUTH ELEV. (FT) PLATFORM STATUS 61405 MAIN ROAD J Al 1 COMMSCOPE - N N H-65A-R2B NEW 55.6 11.9 7.1 35.1 4.6 600 147'-6" RRH 4T4 B2/B66a NEW SOUTHOLD, NY 11971 Q A2 1 COMMSCOPE - N N H-65A-R2B NEW 55.6 11.9 7.1 35.1 4.6 600 142'-8" RRH 4T4 B5/B13 NEW SUFFOLK COUNTY B1 1 COMMSCOPE - NNH-65A-R2B NEW 55.6 11.9 7.1 35. 1 4.6 2200 147'-6" RRH 4T4 B2/B66a NEW SITE TYPE. m B2 1 COMMSCOP E - N N H-65A-R2B NEW 55.6 11.9 7.1 35.1 4.6 2200 142'-8" RRH 4T4 B5/B13 NEW 150'-0" CONCEALMENT POLE Q C1 1 COMMSCOPE - NNH-65A-R2B NEW 55.6 11.9 7.1 35. 1 4.6 3300 147'-6" RRH 4T4 B2/B66a NEW C2 1 COMMSCOPE - N N H-65A-R2B NEW 55.6 11.9 7.1 35. 1 4.6 3300 142'-8" RRH 4T4 B5/B13 NEW COPYRIGHT©2021,AZIMUTH SERVEENGDERINGP.C.,LLCALL RIGHTS RESERVED �I THIS DRAWING AND ALL THE INFOP.MATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WO=K WAS CONTRACTED OR TO WHO11 IT IS CERTIFIED. THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH W ENGINEERING P.C., LLC. N SHEET TITLE: z Q ANTENNA PLANS & 5 ANTENNA SCHEDULE z 0 0— SHEEI (IUMHI,,: LIJ -10 m J Q 49-011 a TOP OF PROPOSED FIRE o PROPOSED FIRE DISTRICT DISTRICT WHIP ANTENNAS(--J, ` { ANTENNA MOUNTED AT TOP OF EL = 11110" ± A.G.L. CONCEALMENT POLE (TYP OF I) (SEE SHEET Z-16) o PROPOSED 5CH '-0" �— TALL PIPE MOUNT (TYP OF 2) N PROPOSED FIRE DISTRICT U) EQUIPMENT (SEE SHEET Z-16)x. ` " TOP OF PROPOSED - ° € :z € cel 'H_€>> 1 r,41(1', . . . TOP DIAMETER OF RADOME CONCEALMENT POLE MULTI-SECTION MULTI-SIDED EL = 150'-0" ± A.G.L. CONCEALMENT POLE = 40 lLITE TOWERS LP 1".Ireles5 Commumc.ations irlrastnu_ture Exffls PROPOSED VERIZON WIRELESS ANTENNA PROPOSED ANTENNA MOUNTED WITHIN CONCEALMENT POLE I CENTERLINE - 146'-10" ± A.G.L. (TYP OF 2 PER SECTOR, 6 TOTAL) I E (SEE DETAIL I, SHEET Z-14)� UI1 11 "" PROPOSED DIPLEXER (4 PER SECTOR, 12 TOTAL) III _ PRO_POSED ANTENNA ` (SEE DETAIL 5, SHEET Z-15) I f CENTERLINE = 141'-2" ± A.G.L. SOUTHOLD BOTTOM OF ANTENNA SECTION LJ po EL = 138'-0" ± A.G.L. ' �. 'I I _III II FUTURE ANTENNA ; CENTERLINE = 132'-0" ± A.G.L. . 11111 U - � BOTTOM OF ANTENNA SECTION �EL — 126'-0" ± A.G.L. ALL STATES PROTECT YOURSELF - e > TIFIIATjiq4 OF EX CAVATORSS DE oCNERS,UIRE OOR AH', PERSON cj� I PPEPARING TO DISTURB THE EARTH'S ' W SURFACE ANYWHERE IN ANY STATE I'll l N KnowwhafsbeloW. I I I Z Call before you dig. Q FOR STATE SPECIFIC DIRECT PHONE NUMBERS > U Z _ FUTURE ANTENNA VISIT: WWW.CALL811.COM CENTERLINE = 120'-0" ± A.G.L. ��- O SALE: UKAWN br: CHEU.ED Ef'r. III 0 U AS SHOWN WAS JKM n- w u uI. ' V) ---- ---- -- ---- ---- BOTTOM OF ANTENNA SECTION ---- ---- - J EL = 1 14'-0" ± A.G.L. ---- ---- 0 12/23/21 ISSUED FOR FILING WPK WS n'I E 10/15/21 REVISED PER COMMENTS GJB JWS II' D 05/12/21 REVISED PER COMMENTS WAS JWS C 05/03/21 REVISED PER COMMENTS WAS JWS III 'III' FUTURE ANTENNA �� — - B 04/29/21 REVISED PER COMMENTS WAS JWS CENTERLINE = I08-0 ± A.G.L. I, A 04/06/21 ISSUED FOR REVIEW WAS JWS REV DATE DESCRIPTION D Y CHECKED I UI- PROPOSED FIRE DISTRICT CABLES ROUTED BOTTOM OF ANTENNA SECTION WITHIN CONCEALMENT POLE TO FIRE ,.�` r✓ . r EL = 102'-0" ± A.G.L. I DISTRICT ANTENNAS (TYP OF I) 7.�r��,\��}, �.. w I II I'I I II _ FUTURE ANTENNA CENTERLINE = 96'-0" ± A.G.L. ysF N0. 0 III 'I II L ul W REMf K McKEON BOTTOM OF ANTENNA SECTION NEW YORK LICENSED PROFESSIONAL EL = 90'-0" ± A.G.L. PROPOSED VERIZON WIRELESS 7/8"Q3 COAX CABLES ROUTED ON ENGINEER-LICENSE NUMBER:095374-I I ' PROPOSED CABLE BRIDGE TO TOWER (TYP OF 4 PER SECTOR, 12 TOTAL) IT IS A, VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION I,I I.I OF THE RESPONSIBLE LICENSED PROFESSIONAL FUTURE ANTENNA ENGINEER, TO ALTER THIS DOCUMENT. BASE DIAMETER OF RADOME III 'III, CENTERLINE = 84-0 ± A.G.L. ' MULTI-SECTION MULTI-SIDED j II I J SITE I N E O R M A TI O N CONCEALMENT POLE = 40" II I' 'I II PROPOSED VERIZON WIRELESS DUAL BAND RRH UNIT (TYP OF 2 PER SECTOR, 6 TOTAL) (SEE DETAIL 2, SHEET Z-14) & DIPLEXER I OF 3 PER SECTOR, 9 TOTAL) SITE NO: ALBERTSON MARINE �T JI LII (SEE DETAIL 6, SHEET Z-15) FOR MOUNTING (SEE DETAIL 2, SHEET Z-15) TOP OF BASE POLE iIIIIlli,,BOTTOM OF ANTENNA SECTION EL = 78'-0" ± A.G.L. EL = 78'-0" ± A.G.L. PROPOSED FIRE DISTRICT EQUIPMENT CABINET ON 4'-0" x 6'-0" 61405 MAIN ROAD PROPOSED VERIZON WIRELESS CABLE CONCRETE EQUIPMENT PAD (SEE SHEET Z-16) SOUTHOLD, NY 11971 BRIDGE (SEE DETAIL 4, SHEET Z-14) PROPOSED 12'-0" WIDE ACCESS GATE I OF 2 x 6'-0") (BY ELITE) (SEE DETAIL I, SHEET Z-13) SUFFOLK COUNTY PROPOSED VERIZON WIRELESS PROPOSED VERIZON WIRELESS UTILITY METER MOUNTED IN OPEN SOCKET(BY ELITE) SITE TYPE: TOP OF VERIZON WIRELESS GPS UNIT STEEL CANOPY (ABOVE) I 150'-0" CONCEALMENT POLE EL - 13'-6" ± A.G.L. PROPOSED VERIZON WIRELESS GPS PROPOSED MULTI METER-METER PACK WITH DISCONNECT (BY ELITE) TOP OF VERIZON WIRELESS STEEL CANOPY ANTENNA MOUNTED ON PROPOSED j PROPOSED MESA CABINET (BY ELITE) -- - CANOPY (SEE DETAIL 3, SHEET Z-15) COPYRIGHT m 2021,AZIMUTH ENGINEERING P.C.,LLC ALL 11'-6" ± A.G.L. — — TOP OF VERIZON WIRELESS CABINET,_ [THIS DRAWING AND ALL�GHTTHEISRESERT`I'CEDCONTAINED HEREIN IS EL 9'-8" ± A.G.L. AUTHORIZED FOP. USE ONLY BY THE PARTY FOR WHOM THE PROPOSED VERIZON WIRELESS EQUIPMENT CABINET & / — WORD was CONTRACTED OR To WHOM IT D, CERTIFIED. THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, > BATTERY CABINET (BEYOND) (SEE DETAIL I, SHEET Z-15) TOP OF FIRE DISTRICT EQUIPMENT CABINET�� DISTRIBUTED E RELIED WRIT FOR ANY OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH ILLI - -_ _---_ -- EL = 6'-10" ± A.G.L. IJ ENGINEERING P.C., LLC. PROPOSED V-0" HIGH BLACK CHAIN LINK FENCE n O TOP OF CHAIN LINK FENCErjLLJ _ SHEET TITHE. z (BY ELITE) (SEE DETAIL I, SHEET-13) 00 EL = 6'-0" ± A.G.L. IJ ELEVATION �� TOP OF PROPOSED VERIZON WIRELESS STEEL PLATFORM; o ----- - - --11` A. EL = T-0" ± G.L. [11LLI NUMBER: r7 LLI1 SOUTH EAST ELEVATION GRAPHIC SCALE 5 + 3 4 0 =5 5 1 SCALE:3/16"= 1'-0"FOR 22"x34"DRAWINGS L�-11 m (IN FEET)_ SCALE:3/32" = 1'-0"FOR 11"x17"DRAWINGS Q o FINISHED GRADE- MATCH SLOPE THICKNESS FINISHED GRADE- MATCH SLOPE THICKNESS 2�-0��± EXISTING GRADE AND MATERIAL OF EXISTING CONDITIONS AND MATERIAL OF EXISTING CONDITIONS— OR ONDITIONS OR AS DIRECTED BY THE ENGINEER OR AS DIRECTED BY THE ENGINEER / t 0 21-4"* 2141* J - � WARNING TAPE WARNING TAPE I f WARNI - - - - NG TAPE i I 1 TRENCH = Q - o CD COMPACT FILL (90%) OR — I - \�-- - N _ o � ¢ AS PER UTILITY COMPANY Z - UNDISTURBED SOIL ;o Z UNDISTURBED SOIL -- REQUIREMENTS - — I — — - - - — _ - E _ - I ' \ III — � ��S LP a I II _ [ fir' iVi,e!ess ommum,,atn,i�WIRStr lCtUre EXPeIS � o CLEAN FILL (COMPACTED CLEAN FILL (COMPACTED �O IN 12" CONTROLLED LIFTS) " IN 12" CONTROLLED LIFTS) - 6�� 611 - _ 6 _ 6 - = Q -a - o I �—UNDISTURBED SOIL - R, „s MIN MIN �O MIN MIN I LITH 1\ --pl 0 ---CLEAN SAND CLEAN SANDJ \\ I01 �\ —(1) 2" PVC ELECTRIC CONDUIT CLEAN SAND SUITABLE - 4"0 SCH 40 TELCO CONDUIT I'-0" �— \'�(2) 4 PVC ELECTRIC CONDUIT (WITH 2O0LB MINIMUM PULL WIRE) _ FOR CONDUIT BEDDING \ (I) 2 PVC TELCO CONDUIT MIN NOTE: NOTE: (2) 4 2"0 SCH 40 PVC ELECTRIC CONDUIT PWC TELCO CONDUIT ; II. MINIMUM SEPARATION PER TELCO AND 1. MINIMUM SEPARATION PER TELCO AND NOTE: UTILITY COMPANY REQUIREMENTS. UTILITY COMPANY REQUIREMENTS. I. IF FREE OR ORGANIC OR OTHER DELETERIOUS MATERIAL, EXCAVATED MATERIAL MAY BE USED FOR BACKFILL. 2. IF NOT, PROVIDE CLEAN, COMPATIBLE MATERIAL. COMPACT IN 8" LIFTS. REMOVE ANY LARGE PROTECT YOURSELF ROCKS PRIOR TO BACKFILLING. CONTRACTOR TO VERIFY LOCATION OF EXISTING U/G a ALL STATES REQUIRE RB THE TION 'S EXCAVATOPS. DESIGNERS, OR ANY PERSON 1 DEIMIA.RC TO SHELTER TRENCHING DETAIL GRAPHIC SCALE N.T.S. 2 SOURCE TO DEMARC TRENCHING DETAIL GRAPHIC SCALE N T S PREPARING TO H TURN THE EARTHS U. SURFACE ANYWHERE IN ANY STATE — _ (IN FEET) • • • UTILITIES PRIOR TO DIGGING. Know what's below. (IN FEET) 3. IF CURRENT AS-BUILT DRAWINGS ARE NOT AVAILABLE, CONTRACTOR SHALL HAND DIG U/G Call before you dig. TRENCHING. FOR STATE SF'ECIFIC DIRECT PHONE NUMBERS MATCH EXISTINGRIGID STEEL VISIT: WWW.CALL81I.COM EXISTING MATERIAL & GRADE RIGID STEEL CONDUIT GRADE EXPANSION COUPLING—�� CONDUIT PLUG ;CALL: JRAVVIJ BY: -HEIKtU Ht: 3 JOINT SERVICE TRENCH DETAIL GRA��SSC,ALE N.T.S. AS SHOWN WAS JKM 111-111=1 '77,/ 1-111-111=1 ---- ---- -. ---- ---- II III CLEAN BANK RUN GRAVEL. :o GRADE - BACKFILL WITH NO STONES 3/4" GRAVEL STONE � �----- 0 12/23/21 ISSUED FOR FILING WPK JWS GREATER THAN 6". COMPACT III I— TO 95% MODIFIED PROCTOR. %`////% / � '%" '% %moi'%% 'i'�%%%' 3/4 " CRUSHED STONE E 10/15/21 REVISED PER COMMENTS GJB JWS -I I \ '�\\'i';.% \ \ '��/\ \ �\' �\ [V z ASTM C33, SIZE NO. 57 D 05/12/21 REVISED PER COMMENTS WAS WS ' °° II I I _YELLOW WARNING TAPE �A � J III6" WI MARKED "CAUTION - GAS MAIN" DE UTILITY WARNING TAPE c 05/03/21 REVISED PER COMMENTS WAS Jws 0 ZO� J, B 04/29/21 REVISED PER COMMENTS WAS JWS III'' J -IZ 0000000000000 000 04/06/21 ISSUED FOR REVIEW WAS JWS o 0000000000000000 � 000000 TRACER WIRE (SEE NOTE #3) DRAWNCHECKE D REV DATE DESCRIPTION BY BY -- - —_ =1 'i I=1 I I-1 I I—III—III—I I Imo— �� I.D. l MINIMUM 1.5 .D. PE PIPE 2'-0" _� \ / RIGID STEEL CONDUIT NOTE: -� I. ALL EXCAVATION SHALL BE HAND EXCAVATION ONLY. _,/ PVC PIPE COMPACTED SUBGRADE RIGID STEEL TO PVC ADAPTER ,. 2. PE PIPE: INSTALLATION SHALL BE IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS. NOTE: 3. A YELLOW INSULATED COPPER TRACER WIRE SHALL BE INSTALL ADJACENT TOrl .> cc WEED BARRIER TYPER ngw �, UNDERGROUND NOIN-METALLIC PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE I. IF COMBINATION METAL AND PVC CONDUIT RUIN IS INSTALLED E.C. SHALL BOND METAL LANDSCAPE FABRIC OR EQUAL OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT EACH END OF THE <� � CONDUIT TO SERVICE PANEL. �F�s� �o. 0953�a NON-METALLIC PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18 AWG AND THE 2. IF PVC CONDUIT IS EXTENDED ABOVE GROUND ALL SWEEPS AND CONDUIT ABOVE GROUNDt 'ESS INSULATION TYPE SHALL BE SUITABLE FOR DIRECT BURIAL. COMPLIANT IFGC SECTION 404.15.3. TO SCH. 80 GRAPHIC SCALE 4. SPLICE'', BETWEEN STEEL GAS PIPE & PE PIPE TO BE THREADED. 6 GRAVEL COMPOUND DETAIL GNFSC N.T.S. �EREM/Y//K MCKE�ON NEW YORK"LICENSED PROFESSIONAL 4 GA�� TRENCHING DETAIL GRHIGN FCEETALE N.T.S. 5 TYPICAL UNDERGROUND CONDUIT STUB-UP GRAPHIC SCALE N.T.S. NOTE: ENGINEER- LICENSE NUMBER:095374-I (IN FEET) 1. PROVIDE 3" LAYER OF MULCH AS SPECIFIED EMERALD GREEN ARBORVITAE IT IS A VIOLATION of LAW FOR ANY PERSON, 1 ,r UfILESS THEY ARE ACTING UNDER THE DIRECTION OVER ENTIRE WATERING SAUCER AT ALL of THE RESPONSIBLE LICENSED PROFESSIONAL TREE PITS OR OVER ENTIRE TREE BED. 6'-0" IN HEIGHT MIN. ENGINEER, To ALTER THIS DOCUMENT. 2. PREPARED BACKFILL MIXTURE: I PART PEAT, I PART HUMUS, I PART PARENT SOIL. \ SITE INFORMATION : CONCRETE CAP BACKFILL SHALL BE THOROUGHLY MIXED. jj 2 STRANDS NO. 12 GA. GALV. 6"0 SCHEDULE 40 CARBON WATER IN 12: LIFTS DURING PLANTING. II ANNEALED STEEL WIRE - TWISTED SITE NO: ALBERTSON MARINE STEEL PIPE WITH YELLOW II IN NEW RUBBER HOSE SLEEVE FILLED WITH CONCRETELu UU W I 2 STRANDS DOUBLE 61405 MAIN ROAD PROPOSED TIMED LIGHT (RB P/N STL360H) I— I WRAPPED AND TWISTED SOUTHOLD, NY 11971 (TYP OF I PER ICE CANOPY POST, TOTAL OF 4) 0O O Z I CIRCLED WATERPROOF TREE WRAPPING SUFFOLK COUNTY GRADE, PAVEMENT OR— � � I FINISHED GRADE PAPER 4" WIDE, 50% OVER LAP. TIED WITH _Z 1 ��STOUT HEMPCORD AT TOP OF BALL AND SITE TYPE: CUT & REMOVE BINDING FROM I I AT HEIGHT OF SECOND BRANCHES 150'-0" CONCEALMENT POLE -------- 3"QOxIO'-0" LONG SCH. 40 PIPE TRUNK AND AS MUCH FROM BALL ! I PITCH AWAY FROM TREE TRUNK AS POSSIBLE. CUT AND REMOVE UPPER 1/3 OF BURLAP FROM BALL /,--FINISHED GRADE COPYRIGHT 2021,AZIMUTH ENGINEERING P.C.,LLC ALL ' � Z Q � RIGHTS RESERVED THIS DRAWING AND ALL THE INFORMATION CONTAINED HEF.EIN IS ' AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOI,,4 THE CONCRETE FOOTING (4,000 PSI) ih E Z WORK WAS CONTRACTED CP, TO WHOM IT IS CERTIFIED. THIS O L /, ^. DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, p 0 GFCI DUPLEX OUTLET WITH NEMA xy ` TOPSOIL MIX BACKFILL DISTRIBUTED OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH w311 OUTLET COVER (TYP OF 2) `O ENGINEERING P.0, LLC. o NOTE: N — TREE BALL Lv - v SHEET II SLE: I. MOUNT TIMED LIGHT & OUT PER _ VARIES TAMPED TOP SOIL < MIN MANUFACTURERS RECOMMENDATIONS I ICONSTRUCTION DETAILS - 1 I'-0" I'-0" MIX CUSHION 6" z 0 SHEET NUMBER: ft Lij 7 BOLLARD DETAIL GRAPHIC SCALE N.T.S. GRAS SET ALE GRAPHIC SCALE m — (IN FEET) 1�I 1 V 8 TIMED LIGHT & OUTLET DETAIL N.T.S. 9 TREE PLANTING DETAILS (IN FEET) N.T.S. Z-12 Q I� 1 o r 3/8"0 TRUSS ROD WITH HEAVY-DUTY GALV. LOCKABLE, C TURNBUCKLE AT GATE ONLY DOUBLE GATE LATCH �J cl� VARIES 12'-0" GATE OPENING N 10'-0" MAX i VERIFY WITH SITE PLAN , /-1 I/4" GATE FRAME TYPICAL CHAIN LINK FENCE NOTES 1. GATE POST, CORNER, TERMINAL OR PULL POST 2 1/2"Q3 SCHEDULE 40 FOR GATE U `=`` \ /� WIDTHS UP THROUGH 4 FEET PER ASTM-F 1083. I I/4" TOP RAIL 2 1/2 CORNER POST 2. LINE POST: 2"0 SCHEDULE 40 PIPE PER ASTM-F1083. 2 x2 _ 9GA. FENCE FABRIC / 5/8"Q} / 3. GATE FRAME: 1 1/2'0 SCHEDULE 40 PER ASTM-F1083. ELITE TOWTRS LP LATCH ROD helps,,Comrnuracatio%ir7 sc v:ri:re Expi,,t 2 I/2" GATE POST 3/16" x 3/4" STRETCHER BAR 4. TOP RAIL & BRACE RAIL: 1 1/2"0 SCHEDULE 40 PER ASTM-F1083 :0 2" INTERMEDIATE POST yV AT CORNER AND GATE POSTS M., 5. FABRIC" 12-GAUGE CORE WIRE SIZE 2-INCH MESH, CONFORMING TO ASTM-A392 I R " NO GAP BETWEEN FINISH 1/2" CROWN FOR DRAINAGE \ GRADE AND FENCE FABRIC . ° 11111 TIE WIRE: MINIMUM I I-GAUGE GALV. STEEL AT POSTS AND RAILS A SINGLE WRAP '0 2:1 SLOPE MAX OF FABRIC TIE AND AT TENSION WIRE BY HOG WITH FABRIC 14-GAUGE, L X ; . MIN 4-POINT BARBS SPACED ON APPROXIMATELY 5 INCH CENTERS BLACK s Z 7. TENSION WIRE: 7-GAUGE GALV, STEEL. �p -- STONE OVER =1 —I 8. GATE LATCH: DROP DOWN LOCKABLE FORK LATCH AND LOCK, KEYED ALIKE GEOTEXTILE FABRIC I'-0" 0 TIRE AT END OF w =1 1- 3:1 SLOPE MAX FOR ALL SITES IN A GIVEN MTA. Z SWING GATE (TYP OF 2) Q Iw to w 1) #7 GA. TENSION WIRE, 9. HEIGHT = 6FT VERTICAL. 6"0 x 18" DEEP CONCRETE '''' � p 111= CONTINUOUS 8 FOOTING WITH 1 1/4" PIPE O 2: a II II 10. ALL FENCE COMPONENTS SHALL BE BLACK VINYL COATED INCLUDING CHAIN ` SLEEVE 6" LONG m p — ° 11=1 LINK FENCING. LU 10"o CONCRETE BRAIDED COPPER GROUND STRAP, 2 PL PROTECT YOURSELF 12"0 CONCRETE FOOTING IN SOIL _ ALL STATES REQUIRE NOTIFICATION OF FOOTING IN SOIL FORJ FOR GATE AND CORNER POSTS (SEE GROUNDING SPECIFICATIONS) Z a INTERMEDIATE POSTS Q Ein xCAVA FI S, DESIGNERS, OR ANY RTH'S d ^+, PREPARING TO DISTURBIN THE EARTH'S SURFACE ANYWHERE IN ANY STATE Know what's below. Call before you dig. FOR STATE SPECIFIC DIRECT PHONE NUMBERS VISIT: WWW'.CALL8JI.COM SCALE jrtAWN L,r CHECKED B r: AS SHOWN WAS JKM ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1 FENCE & ACCESS GATE DETAIL GRAPHIC SCALE N T S 0 12/23/21 ISSUED FOR FILING WPK JWS (IN FEET) • • • — E 10/15/21 REVISED PER COMMENTS GJB JWS D 05/12/21 REVISED PER COMMENTS WAS JWS UNISTRUT PIPE / CONDUIT CLAMP P 1 1 19 C 05/03/21 REVISED PER COMMENTS WAS I JWS OR P2558-35 (GALV.) (TYPICAL) FOLLOW B 04/29/21 REVISED PER COMMENTS WAS JWS MANUFACTURERS RECOMMENDATIONS A 04/06/21 ISSUED FOR REVIEW WAS JWS REV DATE DESCRIPTION DRAWN CHECKED FOR BOLT TORQUE CONCRETE PAD W/3/4" CHAMFER BY BY �3 1/2" O.D. POST 4" #3 @ 12" O.C. EACH WAY —� (TYP) 2.. FINISHED GRADE _I 41''. 3"0 RGS CONDUIT � � _ _ A (GALV. (TYP) � II TII I _,�__ � - ��?� � . ��_,�CITI, -� �����':I, ,� a :_ :,` cic 4-0 —I I I5I 1-i =1 I— 4 —_�-1 I� L _ - 1_II-III=III=III-1 1== -III=I_I=1II1=1II-111=1 r . cS<c�N METER BANK 'MA' o. 095 X11 " - = '—�I= — �F2� PROPOSED WATERTIGHT METER \ �6" COMPACTED CRUSHED HEAVYSOCKET COVER �� NAME PLATE PIPE CAP (TYP) - - `� STONE OR GRAVEL €RE K�McKEON TYP CONCRETE UNDISTURBED OR COMPACTED SOIL (TYP) NEW YO LICENSED PROFESSIONAL w N2 EQUIPMENT PAD -- ENGINEER- LICENSE NUMBER: O 095374-I � M E �� ~ CONCRETE PAD Q _ IT IS A VIOLATION OF LAW FOR ANY PERSON, W V N 1 N3 A B t (THICKNESS) UNLESS THEY ARE ACTING UNDER THE DIRECTION W_ O OF THE RESPONSIBLE LICENSED FROFESSIONAL p U " MAIN O FRONT VIEW SIDE VIEW MESA CABINET 4' 3' 6" ENGINEER, To ALTER THIS DOCUMENT. JRE DISTRICT CABINET 4 TERMINAL 85.37 ' 6 6w O F SITE N E O R M A TI O N :N,31 3 LUGS SECTION UNISTRUT P5000 (GALV.) Ap 30.94" I O O O _ SITE NO: ALBERTSON MARINE N 3 EN-3] 61405 MAIN ROAD 00 SOUTHOLD, NY 11971 \�' ,\`. •I I. j��\ji� N \ °° #3 @ 12" O.C. EACH WAY A //' , SUFFOLK COUNTY N Ia j j, Ia SITE TYPE: LriP M -- 1 P°. °.I "' j 150'-0" CONCEALMENT POLE 14, - - - - - - - I / o CONCRETE PAD _ N (CAST-IN-PLACE N-PLACE COPYRIGHT©2021,AZIMUTH ENGINEERING P.C.,LLC ALL RIGHTS RESERVED OR PRECAST) THIS DRAWING AND Al L THE INFORMATION CONTAINED HEREIN IS j / NOTE: AUTHORIZED FOR USE ONLY B) THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. THIS CD DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, > 1. USE GALVANIZED HILTI EXPANSION ANCHORS OR APPROVED DISTRIBUTED E RELIED UPON FOR AN r OTHER PURPOSE w 12"0 PLAIN CONCRETE PIERJ EQUAL, FOR EQUIPMENT ANCHORAGE. WITHOUT THE E Er�IVEERIN�TPCcCLsErJT OF AZIMUTH o (4,000 PSI CONCRETE) MESA PER-INSTALLED N NOTE: DISTRIBUTION PANEL PLAN VIEW 2. FOR SIZE AND LOCATION OF ANCHORS AND OTHER SHEET TITLE: w REQUIREMENTS, SEE EQUIPMENT VENDOR DRAWINGS. z C I. MOUNT METER BANK AND MAIN LUGS SECTION PER MANUFACTURERS RECOMMENDATIONS AND INSTRUCTIONS. 3. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 4,000 PSI CONSTRUCTION DETAILS - 2 L O SHEET NUMBER: 2 MULTI POWER METER BANK MOUNTING DETAIL GR GNFEETALE N.T.S. 3 MESA CABINET DETAIL G�(INFEETALE N.T.S. 4 CONCRETE EQUIPMENT PAD DETAIL GRA STALE N.T.S. Z-13 Q - Q 0 11.911 7.1" o r r 12.1" 12.1" 0 r� O O O O O O O O 5. �. , .. .._. .. ,: 7 U) NOKIA NOKIA .R . . r,. 0 a• 4.a C13 1 1'1; EH{Er 3,I I°-1t _. .. U L ELITE: Tmvf_,,Rs i_P OVYeiess Communrcatrwis In`rastn,:N,re ExpF-ts i C-4 ni Ln 77� I i 1 LnI 51OUTHOLD), LnL 44� i F1 o x2w PROTECT YOURSELF Ju. ALL STATES PEOUIRE NOTIFICATION OF B2/66a AHFIC REMOTE RADIO HEAD B5/B 13 AHBCC REMOTE RADIO HEADExCAVA RIIJG O "ERs, °R ANY RTH'ON PREPARIf!G TO DISTURB THE EARTH'S SURFACE A10WHERE IN ANY STATE MANUFACTURER: NOKIA MANUFACTURER: ALCATEL-LUCENT Know whiPsbelow. Cal I before you dig. NOTES: POWER SUPPLY: -48VDC POWER SUPPLY: -48VDC FOR STATE SPECIFIC DIRECT PHONE NUMBERS VISIT: WWW.CALL81I.COM I DIMENSIONS SUBJECT TO CHANGE DIMENSIONS: 22.0"Hx12.1"Wx7.I"D DIMENSIONS: 22.0"Hx 12.1"Wx7.54"D -1 — . SCALL: IDPA*N Bi- CHEM ED d r. BASED UPON AVAILABILITY AT WEIGHT: <80.0 LBS (WITHOUT WEIGHT: <84.0 LBS (WITHOUT AS SHOWN WAS JKM TIME OF CONSTRUCTION MOUNTING BRACKET MOUNTING BRACKET WEIGHT= 35.1 LBS 0 12/23/21 ISSUED FOR FILING WPK JWS ANTENNA FACE AREA =4.6 SQ. FT. E 10/15/21 REVISED PER COMMENTS GJB JWS COMMSCOPE- NHH-65A-R2B ANTENNA DETAIL D 05/12/21 REVISED PER COMMENTS WAS JWS C 05/03/21 REVISED PER COMMENTS WAS JWS B 04/29/21 REVISED PER COMMENTS WAS JWS A 04/06/21 ISSUED FOR REVIEW WAS JWS 1INGRAPHIC SCALE N.T.S. RRH DETAILS GRAPHIC SCALE REV DATE DESCRIPTION DRAWN CHECKED FEET) lel 1 s BY BY ANTENNA DETAILS (IN FEET) N•T•S• POST CAP (TYP) CO UUHEAVY DUTY Z GRIP-STRUT SFO 0. 0953�� wT-O" WIDE A9�F-ssI "I U w w LU �WAVEGUIDE J6REMY4 McKEON C:, 0 E- NEW YORK LICENSED PROFESSIONAL o w Z CROWN EACH ENGINEER- LICENSE NUMBER:095374-1 — = FOOTING 2" A.F.G. IT IS A VIOLATIOrI OF LAW FOR ANY PEF'SON, Q UNLESS THEY ARE ACTING UNDER THE DIRECTIOIJ LZ—L _ FINISHED GRADE of THE RESPONSIBLE LICEIJSED PROFESSIONAL 0 0 00 00o 00 00 ENGINEER, TO ALTER THIS DOCUMEI;T. 0000 000 00 000 o i 0 0 09 o°oho 0o 0 0o SITE INFORMATION : %0�— —III—III III—I M i l l l l l l l l l l I I I � COMPACTED SITE NO: ALBERTSON MARINE —III= SUBGRADE \—CONCRETE 61405 MAIN ROAD FOOTING (4,000 PSI) SOUTHOLD, NY 11971 SUFFOLK COUNTY NOTES: I. CABLE BRIDGE SHALL BE SITEPROI GRIP STRUT TRANSMISSION LINE SITE TYPE: BRIDGE KIT (PART NO. I B24D-216T3) OR APPROVED EQUAL. 150'-0" CONCEALMENT POLE 2. ALL COMPONENTS SHALL BE INSTALLED ACCORDING TO MANUFACTURERS SPECIFICATIONS. 3. CONTRACTOR SHALL DETERMINE REQUIRED QUANTITY OF ALL CABLE COPYRIGHT©2021,AZIMUTH ENGINEERING P.C.,LLC ALL RIGHTS RESERVED BRIDGE COMPONENTS. THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE -0 4. SNAP-IN HANGERS, SPLICE KITS, HINGE KITS, EXTENSION KITS, WORK WAS CONTRACTED OR To WHOM IT IS CERTIFIED. THIS 0 DRAWING MAY HOT BE COPIED, REUSED, DISCLOSED, STIFFENERS, AND OTHERS MISCELLANEOUS HARDWARE SHALL BE DISTRIBUTED OR RELIED UPON FOR ANY OTHER PURPOSE W PROVIDED BY THE CONTRACTOR AS REQUIRED. WITHOUT THE EXPRESS IEWRITTEN ING P CCOLCENT OF AZIMUTH 0 5. CABLE BRIDGE SHALL BE ROUTED TO ACCOMMODATE THE MINIMUM N Lv BENDING RADIUS OF THE COAXIAL CABLE. SHEET TiTEE. 6. CABLE BRIDGE COMPONENTS SHOWN ARE SCHEMATIC, CONSULT MANUFACTURER FOR EXACT AND CURRENT SPECIFICATIONS EQUIPMENT DETAILS - 1 z 0 SHEET NUVHER: m 3 NOT USED 4 CABLE BRIDGE DETAIL GR�HIFCEETALE N.T.S. 5 NOT USED Z-14 J _ — -- Q Q NOTES: LIFTER EARS-� 37.7" I. MOUNT RRH'S AS PER MANUFACTURERS RECOMMENDATIONS. 2. CONTRACTOR TO VERIFY THAT RRH CLEARANCE REQUIREMENTS ARE MET. 34.1" \ 23.8" 32.0" 37.8" 3. JUMPERS & CABLES NOT SHOWN FOR CLARITY + N 4. RRH'S SHALL BE SPACED A MIN. OF 4" APART ON PROPOSED H-FRAME o o GPS ANTENNA CJ OHO° - _ __= 000 (PROVIDED BY VERIZON WIRELESS s ' -_- - INSTALLED BY CONTRACTOR) u , ; .: F-)1 € 3 r_, V 0 PROPOSED RRH'S - - 0 "/ (TYP OF 2 PER SECTOR, 6 TOTAL) CABLE ENTRY 1 1/2" O.D. x T-0" MAX GALV. - (TYP) - STEEL MOUNTING PIPE LITS �4ONVE ` S LP PROPOSED 4Vlfeless Comrnjn�,.alia,t In`awful Lure E:{,-pls PROVIDE APPLICABLE o = O o -`CABLE ENTRY- HANDRAIL POST I- � 11". r4 - - Ci PIPE TO PIPE CLAMP - 0 0 0 0 ^ O 0 I 1/2"0 GALV. U-BOLT °� O COAX GROUND KIT O ° - REVERSIBLE - - CABLE BRIDGE POST/PIPE MAST-\ SOUTHOLD LMOUNTING �� „9 O COAX CABLE AS REQ UIRED BY :� IS - K T MANUFACTURER ' /// --------ANTENNA ) p . O O O PROPOSED UNISTRUT O - O END CAP �6 AWG GROUND WIRE TO O O CADWELD ON POST OR LUG ON GROUND BAR 31.711 45.5 34.6 mA [Till, d O PROPOSED P I OOOT fig, UNISTRUT (TYP) (CUT TO �� NOTES: ESOF016-ECAOI (DC-AIR/DAC) LENGTH IN FIELD ° O ES0F024-ECx01 CABINET �% `� � POWER EQUIPMENT o �9 y % �9 I. LOCATION OF ANTENNA MUST HAVE CLEAR VIEW OF SOUTHERN SKY AND PROTECT YOURSrLF ALL STATES REuIJIRE NOTIF(CATION OF " O , ® ExCAVATORS, DFS'GNERS, OR ANY PEPS9N HEIGHT: 72.0" HEIGHT: 72.0 �y� �� O CANNOT HAVE ANY BLOCKAGES EXCEEDING 25/ OF THE SURFACE AREA OF / -\ \J L%y vy + PREPAP.III; TOYWHERE IN ANY STATE DISTURB THE EARTH'S WIDTH: 31.7" WIDTH: 32.0" O A HEMISPHERE AROUND THE GPS ANTENNA. KSURFA E A'lnow what's below. a� Call before you di g.v DEPTH: 45.5" DEPTH: 34.6" L 2. ALL GPS ANTENNA LOCATIONS MUST BE ABLE TO RECEIVE CLEAR SIGNALS FOR STATSPEECI,IC DIRECT PHONE NUMBERS FROM A MINIMUM OF (4) SATELLITES. VERIFY WITH HANDHELD GPS BEFORE VISIT: WWW.CALLEII.COM WEIGHT: 578 LBS (RECTIFIERS & WEIGHT: APPROX. 690 LBS (RECTIFIERS EQUIPMENT EXCLUDED) & EQUIPMENT EXCLUDED) FINAL LOCATION OF GPS ANTENNA SCALE: JDFAWH B1. HEc.I LD 31: AS SHOWN WAS JKM ---- ---- ---- ---- ---- 0 12/23/21 ISSUED FOR FILING WPK JWS 1 EQUIPMENT CABINET DETAIL GRA`PHIECESTCALE N.T.S. 2 RRH MOUNTING DETAIL GR(IN FEET)PHICSCALE N.T.S. 3 GPS ANTENNA GRA(INFEEET) N.T.S* E 10/15/21 REVISED PER COMMENTS GJB JWS D 05/12/21 REVISED PER COMMENTS WAS JWS NOTES: C 05/03/21 REVISED PER COMMENTS WAS JWS B 04/29/21 REVISED PER COMMENTS WAS JWS ----- ----------- ------------... - - -- - - - - - -- -.--- -- .... - - 1. MANUFACTURERS __._ . 4.. .. 3 - ----�--` . . I; .. . _. .. 2 1 l RECOMMENDATIONS AND VERIZON STANDARDS. DRAWN CHECKED A 04/06/21 ISSUED FOR REVIEW WAS 1.0 GENERALoRe"sw"s 1.1.ALLMETERICDIMENSIONSAREINBRACKET [ oE•,. r Een `r EstRrnex BY a. T bare REV DATE DESCRIPTION gY 2.0 DESIGN NOTE I__AA--IaaMM971 IN1114 RELEASE EA-- CW+vke 2.1 PIPE SIZE RANGE-4.5'-6.0"00 2. MOUNT EQUIPMENT PER MANUFACTURERS RACOMMENDATIONS. 2.2 ANTENNA MODELS SHOWN-COMMSCOPE PART#SDIAHH-1D656-0L 3,0 MANUFACTURING'SPECIAL REQUIRMENTS (04.5"OD PROPOSED UNISTRUT 4.0 TEST PIPE SHOWN FOR REFERENCE 5.0 PACKAGING (04.5 -06.0") I 3. CONFIRM REQUIRED EQUIPMENT WITH LATEST RFDS. END CAP 6.511 A;�•, rw 2 HIDDEN IN DETAIL A 3 4 h ' A I �c �'6 0g53 �PROPOSED 1/2" HILT[ HIT-HY 70 ANCHOR W/ 3.5" MIN. r'' . a G O op E�ss� EMBEDMENT (TYP) O JCREM K McKEON i ( � 10, NEW YORK LICENSED PROFESSIONAL ENGINEER- LICENSE NUMBER:095374-1 / C 5 C' APPLY TORQUE ' 0. IT IS A VIOLATION OF LAW FOR ANY PCF.SON, PROPOSED ELECTRICAL PANEL 15-23 FT-LBS DETAILA SCALEIA 00 UNLESS THEY APE ACTING UNDER THE DIRECTION �-(MOUNT PER MANUFACTURERS ANTENNA SHOWN FOR O 0 Ln OF THEENGINEER,RSN (BLE LICENSED I ENSIS DOCUMESSIONAL RECOMMENDATIONS) REFERENCE ' O R �. e. 0 o SITE INFORMATIO\� : • i O O SITE NO: ALBERTSON MARINE / 0 0 0 0 0 B p aI - • B ; 61405 MAIN ROAD o ; SOUTHOLD, NY 11971 a SUFFOLK COUNTY I COMMSCOPE, INC.OF NORTH CAROLINA __ _ SIDE VIEW FRONT VIEW SITE TYPE: TOLERANCES SAP MATERIAL VASTER L7 1 mcE xt 0.25 2PACE xxt 0.06 MTC37319 i 150'-0" CONCEALMENT POLE +PLACE x t 0.12 ANGLES t 2° 4 FINISH MATERIAL j ITEM PART NO. DESCRIPTION OIY. 'WEIGHT NOTE NO. GALVA123 A1011/A1018GR36 IE DIPLEXER 1 MTC373108 WELDMENT,NON AZIMUTH ANT MOUNT 4 4,98 LBS I 2 MTC373102 ANTENNA MOUNT BRACKET G 1.05 Les NAVE GATE TITLE COPYRIGHT®2021,AZIMUTH ENGINEERING P.C.,LLC ALL PROPOSED TELCO BOX 3 GB-03125 3/8"x,-v4°GALvBOLT KIT ,2 o.o6LBs p-* NON STD AZIMUTH ANTENNA MOUNT MANUFACTURER: RFS RIGHTS RESERVED (MOUNT PER MANUFACTURERS A 4 GWF-03 3/8-GALV FLAT WASHER 24 0,01LBs � ` Rw A ; THIS DRAWING AND ALL THE INFORMATION COrJTAIfIED HEREIN IS orr,Erm 0.2e Fain" m:9 Rv 1 AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE 5 GB-03225 X&,!4'GA.LVBOLT KIT 8 0.09L85 ;ACE AREA MASS X67a� ECNoos00003,Ga7` °°��^ NTRG MTC37319 , POWER SUPPLY: FD9R6004/I C-3L „ WORK AWING MAY oR CONT ACTED OR To WHOM IT is CERTIFIED. THIS o RECOMMENDATIONS) VGLUM 33141 N -,F- NOT BE COPIED, REUSED, DISCLOSED, I RELIED UPON FOR ANY OTHER PURPOSE > � DIMENSIONS. 5.8 Hx6.5 Wxl.S D WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH �._ W HFxarr szE wGRxARtA 24 1aoGEL DRAWING SHEET ENGINEERING P.C., LLC. LENGTH .r.. - VERSION STATUS IVI9K7V VEPStON STATUS REG EM7N o PROPOSED PIOOOT -_ ©�,gcommscope,l" ++ „+ C ( RE A G, R -A +0°2 . WEIGHT: 2.6 LBS .___._...._._._ _._-.. ._.. _ e._.__._____._.__.__._ __ ._ UNISTRUT (TYP) (CUT TO 4 3 _ _-. 2__.-....----------------w. _.-.. ._-_.' __....____.__------..-----_-.-------1 �HELr 11 LE: LENGTH IN FIELD Q EQUIPMENT DETAILS - 2 s o� SHEET R: 6 DIPLEXER DETAIL Z-15 m 4 ELECTRIC / TELCO RACK DETAIL GRAPHIC SCALE N.T.S. 5 ANTENNA MOUNT DETAIL GRAPHIC SCALE N.T.S. _ GRAPHIC N.T.S. (IN FEET) QN FEET) Q Q 0 { „-, Single section Multiple Arrays ,. .. £ ... ... .. .... ......_.,,. _..--..... .«_._ .., -.._.>. ..._. • "iii �.''t'"'aoyF<,yp,t :k.•-j., )t z mt.4•p#<��. - Im 77, 0iir^.�tl. .....,7,. .rr, t Part number Description Frequency 5n r t l h 1 MODEL PTP SOa , LED INDKATOP5 Pna'e=sah�S Et erupt fink statu,,and atf'yiTy or Exrt,ndod Range PcE supply Omnis T R^BANDS Wide-band oGerar!an 4.9 to 6.05 GH:(A"'owable ire t nrirs aryl berds ani dldatrd by mdivir4:=P tormt (. r!s=.an,.The mnrt co,7_ NFTVv'ORK MANAGEMENT h-hand end mg-ef•band rimormer2(008y) ` t N BA4040.57 2 x 3dBd omnis with separate feeds 330-426MHz "_` mpibaadsareti.tedhere.) SYSTEMYANACEMENTINGINddual-stackmanacrrieMsupport -� O A V BA4040.67 2 x 3dBd omnis with separate feeds 400-520MHz c. 4 940-4 990 6112(P0,11c S.il`M V) 1°Jeh atTerc via Urcv,rr E",ntg HTTP or HTTPS/TLS° 5.15-51 GHZ SN"=9 A v2r one v3,MI8-11 and Propr°t"a°y FTP MIB Cl� _..__-..I _ _ I 5.25-5,35G1!Z Crrb roWrote.sMacng2r,1NM4.pfSPnorhigher �. Elliptica # EA4Q40.57 � 2 x 5dBd eliipticals with separate foods 330.42OMHz t 5 470-5.725 GH2 Orl;ne spc truOI Marigerp M 4.0 SP4 rlNOrIai5c ar notes xk at eratian) t.-- r, N 5.725-5 850 GHZ ! EA4040-67 2 x 5dBd ellipticals with separate feeds 400-52OMHz „ 5,825-6,05-t G1tZ INSTALLATION Built-in audio and 9raphlca'z ':lance for lin.:optlnitatrwr n....... __...., . _._, ...._.... ..__..._,._..,...,. Offset Sections (HANK-1 IICS 5J0,15,20,30,40,and 45MHzcNomrs COF!rFCTtON DistrrrrhePheraut;tcxsrunitandprimoynr+vu kc nectirxt:r:Rio 310Tre1(TGOrtmtets)uslrgpwrer-over'GiTand `' > OA2020.67 2 x 5dl3d offsets with separate feeds 400.520NI Channe'stzm denend cn individual country rew!i9ons Ethernet:lancror distant"up to 984 feet(300 mntors)ran be achrcvpd using f t,ermt(eAce - �.t - U v r-7 gr n 1,. 1 Sr ECTR&L EFFICiFtd Y_,_. 10!pslHz may mrm • j 17 .� _ ._ ..,w _w .{ „...,. „. _.... •�._=777-77 ...»......- t X L „ CL CFi.A`.laSELECTION � ByDynar^tc5redumOptirrzat!onormerua!nterventon: DIMENSO"1S Intermed0utdorrUnft(0DU): ' .. Dual section combination Dipole Arrays a.,tomaticwiectononStirt upandtottinuatscif-p�t,mt.,liGrt�av�l�;nr en< !n',dtr,371',?,T,(t4.6),W,`qfu3rlt,n,(146"),nePtns':,lin(:Tx) _ -- Ce nn ectorized DX Partnumber Description Width ,Ifei�t3'SmmC12S),Depth9C.mmt357 c FrequencY ) � a SYSTEM UAlt;r Inttnrted Up aT64 d8 vr"r 2O M=1z d:;nne1 a r9 inteyr3ted 2s'dG,artervra;Yarly S w'th madulatian mode th<irret size rod spectrum T } Omnis - _ _ _ .- rI ____. . tl .___._...___ _ __ _ _ Y+E1GH, 6tegarndCNJ41kg{995ihs)inti.rd•agbr,:ko+ Cornectarimd Varies wit mar'u x7an mor.p and antcrm typ BA4040.57L 2 x 3dBd omnis with separate feeds 330-42QMHz - tcnnad^rUedQ U:3?kg(633 lbs)irdte,g bra ke - RECEWEi2 SENSI T LAITY -93 dam wTlh 5 MHz chaniel _ jT m BABO-57L 1 x 6dBd omni 330-420MHz _ .. _.__._..,_.-_ .._ . _ __,..,_,._ _.. ...._ __ ... 0PF72AT''dC,TFh pFRAtLptF -40"to+140°F(-40"to 40"0,incri di^q sn1arrart,t,nn t�� rF t LP ".kfi T a1 i MODJLATIOFiJEREtORCORRiCT!OrdS FartPeemrb-oAdippb%,v�ad,dntcnfrat.res {13modrlitinnlFFCcodingtewlsrancinnfrom 8PSX*,a256GAM dull p�'koadMIM0 TF 1 , Rr ' dl'e'ts-sCof-municationslr`ra5tru.-tureExpets t: � ) BA4040 67L 2 x 3dBd omnis with separate feeds 400 520MHzDUST-WATER IN US O d P,C ECTI„N IP66 and IPE Dt`n1 OC SCHRIE Tma D'•/Kion Duriev(TDD) e. -- .__-,. -_ -•- BA80 67L N 1 x 6dBd omnr 400.520MHz VJ`D SPFFD SURM ,i 200 mph(W kWh) p'ive (,xert transmit rrrve dirty cycles Smit fiegmmy operotino a mus srporafe fes mit and mceive fregtrrnries where atrawect ��• Elliptical Sections byrrgvl?.Vmn POINIRSUPPLY Two ot W%is,, ----"- --- - 7 2x5d6delli ticaiswithse separate 330-420MHz �i; M•__.__._.._._ _.__.__.,._.____. ..OEaonaiTDDs4rch3n+zaicrusingPTP-SYNCModule A{pour Gr+,r,cta 3?WI04°F 0 to-40`C 351a._0-240VAC,50�60Hr t EA4040 5 L P P _.._ .. ._.___. __._-.__. ._. ( ° )' F "' " I '..,_.___..____ __-_.._.. ...-.. .... _ _. Dir+rnrir•ns:K'idtlr 5.?"(13Zmrn},Nr�gh'1.4"(3t:mm;.Dept'r Z"(51mrr) ANTTNNA Intr,3ni=nsj:Flat irr -23 dRi �rlk EA80 57L 1 x 9dt3d efiipticat 330-420MHz prpy ;t� AC t Ofi Cower in3ector 40°io 14p°F(-40°to 4f9°C);7p W;S0 24p VAC,50f6a!!z ,." Connettad.ed:Can operate wi h a se edian o.sopa atety-purrfr ts?d Single-and due'palar'ty antennas through2 x f:typ_k^tn_ Dirnensinns VCdtn 9.75"(250 rrnrc),HeK;ht t.5"(40 mrn),Depth 3"(80 nun) t EA4040.67L 2 x 5dBd ellipticals with separate feeds 400.52OMHz ecnnecinrs(local rent rati ins show be;hacked prior to p:xchase) ni2� g � t a. th G:•;sr:r`t:'r;'c„+ n " ar r EA80-67L 1 x 9dBd elliptical 400-52OMHz POt JER CONS(JNP 10.J 30 W maxlmum Ont, 70 t,wrdt PC2 Sat device on aux,iary Dort) RANGE Up to 174 m cps(700 km} Offset Sections 5ECURI Y FIM 197campliarNki3J255 ti AFS Encryption(optional) n ------- ► OA2020-67L 2 x 5dBd offsets with separate feeds 400 520MHz HTTPS and SNMPv3' PRO ECTIOh ANO SRCff Y - M t t60450-1 IECuOe'0-1,E%%950-1.CSA-(222 NO.60950-1;CB aoloval far G1,.bal ^� IdWit'r-based user mrpuits ----- - y OA40-67L 1 x 9dEld offset 400 52OMHz Confinr:'ia*posswatd rules RAD'O 4.9 GR-17FCCP,1 qY,PS,ill w= S.xrFCC ` «6 ShoAnri above are lower sections only which include a through hamosS to connect your choice of upper section. Even�dherrg aiid and Pn)p.15 saaprwrf EN 3Cl2 Pa30rt s 3Ore orr and4TRI,U2r01sso 8; Event bgg!rg aid ms+aa-arneit;oDf'o^ai logghig via sys!cg EN 372 502;EN 3C 843 fare Cam4eg 02,?1R1,UK Approve!to iF2pr77 g y Disasterreonrryarz+nlrerab4litym.none entC_.__.._.__..._......__._._..-_..__..... Eurajre-EN301490-1anrl4 _,.. .._.__ ...._,____...,_....._,_.._ _..__._.._.,. Al g o Select your upper section from our range of standard UHF Arrays, " P ik' w When ordering a dual secticn combination array you will need to order as follows: E 1. Specify your 1mver Section from the list above eg:BABO-67L PLUS PRalDcot IFFEST73 USER DATA THROVC11PUT Dyrarr caly Yarsah!c up to 45II hib s 2. Specify your single upper section from our range of standard UHF Arrays Maxim ncandit,ans-2x2,45 Mlle channel,256 GAM C r Regulatory tond!tlors for PF binds should be wnfimled prior to system purchase.All bands use the socio han1 'are, E rlexlb'esred a'effideri-i xac'tYlite^sifX mod,:!,°� C3 t , Lite Capadty:Up to t25 MLTs Indivirft�al band^and channel+7AcFhs a'P availible penr!ing tri-at rPgulitory approvals and rPg!on cads ficensPs €., Combination Collinear and Dipole Arrays a,,.ritr Up in 25:)Mt,ps 2 train,maxirlurn transmit Gower and effective radiated povder may vary ba=ed an refit I iEaty G'Dmain and region Cade license, ca ?Omnis Description_.... OrtT„�...- Frequency I Ful Capalty Up to 450Mhps a NJebarcess via HTTPS/TLS is rra'lah!r on AES-enabled radios. Omnis AlsowailobleAthli;erseslimlth,gmaµm,rmcharmelbandw:dth `® Oninisan 7 1 x3dBdomnl 400.52DMHz tATFfJCY I-3msanc-d'nctirm!atrn;y BX4040.67 2 x 3dBd omnis with separate feeds 400-52OMHz 00S 801t:ru°s BXBO.67 1 xIIomni 400-52OMHz PACKET CLASSIFICATION Laver 2 and Laver 3 IEEE 8023D,M1514 Ethernet priority Elliptical Sections PACKET PERrORMANCE Line rate(>650k packet,prr second) FX40.671 x 5dBd elliptical 400.52OMHz TIMING TRANSPORT Synch orous Ethernet:IEEE 153Er? EX4040-67 2x5dDdellipticalswith separate feeds 400-52OMHz PROTECT YOURSELF FRAME SUPPORT JurrWiameurito96Xbvtes , ALL STATES RErUIRE NOTIFICATION OF EX80-67 1 x 9dBd elliptical 400-520M z m EXCAVATORS, DESIGNERS, OR ANY PERSON 19t E!hpn�-cDw vols: PREPARING Tp DISTUP.B THE EARTH'S ro Offset Sections FLEXIBLE t/0 ?Grraabit' rii rData+oPoE@wacw inaut SURFACE AN YW4 CRE IN ANY STATE OX2020-67 2 x 5d9d offsets with separate feeds 400-52OMHz Gigabit P,02.803,rtzPOF e1olt port (U1 x 9dBd offset 400-520MHz SF'P port(sing`e-mode fib^_s rnuit-mode f�b2r and caopor Gigai Eyierret options availatNe) Know .what's below. 0X40 67 wv-��_-__� Cal before you dig. (t1 TIJFiTDM SurTORT 8x11.'E.ITDM(NOven=klrulcorUnit(NIDU)) FOR STATE SPECIFIC DIRECT PHO!dE NUMBERS " M These lower sections are for use with COL Series colinears, They are provided with a through harness to connect your choice of G.823<o-nplianthming VISIT: WWW.CALL811.COM y c COLE(UHF),C01_15(VHF)or C01_17(VHF)coilinea%. CCpo�°e+in;�ut(comnztlt"e with Ac+DtPawerin(r^areLtp+i) : is Ti,E1LATRICY(ONEVV) Ito3mstyplraldrrrrdirrgonrarrge.honfivid!,,m,444iorrri,&and nvinberofTI/Fl prn+s;arcurxtnT??ES' Micyh_nncscanbe When ordering a combinafion Collinear and dipole,array you will need to order as ftiilotvs1 ,.,,Wd:ter rCdf4i8ryg.enCan`igt�a?On4r5!rgthCCom�iUrttFTpLlr7Ka!ann2r SCALE: 1DRAWN B r': JUIELkED Ry. 0 1. Specify your lower Section from the list above eg:BX80-67 PLUS AS % ` 2. Specify your GOL collinear either COL15,GOL17 or COLE eg.GOLB(and remember to specify frequency) SHOWN WAS J KM .Ca E ---- -- ---- ---- 0 ---- ---- -- ---- 0 12/23/21 ISSUED FOR FILING WPK JWS E 10/15/21 REVISED PER COMMENTS GJB JWS 1 350-520 MHz UHF ARRAY CONFIGURATOR DETAIL 2 PTP 650 FIRE DISTRICT EQUIPMENT DETAIL D 105/12/21 REVISED PER COMMENTS WAS JWS C 05/03/21 REVISED PER COMMENTS WAS JWS B 04/29/21 REVISED PER COMMENTS WAS JWS A 04/06/21 ISSUED FOR REVIEW WAS JWS ,f ,"„ :A x x, rrr I r wit, REV DATE DESCRIPTION D y CH Y ED . Weight Height i 205 Lbs.assembled 77.98" 275 Lbs.shipping weight Width z Doors 23.625" • 2,secured by three point locking system Depth CO k • Locks via customer supplied padlocks . See racking specifications 2j" • Sealed with.875"aluminum filled gaskets _Useable depth W Material '' ' I $mak .125"AlumifiiI Finish:Painted cream NEMA Class Types available . RF properties:Non-ferrous NEMA 3R(Vented),NEMA 4 <m� Vents closed loop-a/c),NEMA 4X 2SF�P e 0g53N !r 30 bottom Louvers per door Paint Tested R FESS�� to louvers-in to cover, 1000 Hour salt spray(textured) / 14 P P r I under 1000 Hour immersion CONCRETE PAD f , REMY `N�cKEON = One removable filter panel per door ,; 14 fixed filter pads in top cover " d y ` A B t (THICKNESS) NEW YORK LICENSED PROFESSIONAL Height CABINET 49 3' 4" ENGINEER- LICENSE NUMBER:095374-1 Handles 74„ '1 Zinc,padlocking WidthA IT IS A VIOLATION OF LAW FOR ANY PERSON, UfJLESS THEY ARE ACTING UNDER THE DIRECTION f} OF THE RESPONSIBLE LICENSED PROFESSIONAL i= Rails ("yak hy ,`'" Two sets 19"Rail standard (for additional rails see accessories) Main Body ENGINEER, TO ALTER THIS DOCUMENT. Alodine coated - Height:78.23" " Holes tapped for 10-32 threads - Width:25.5" SITE N E O R M A T I O N : Each rail supported by three R-STRUTSTM1° Depth:3411 UNLESS . .125" Malaria!(Alumiflex(D) Alumishield® OTHERWISE ONN SITE NO: ALBERTSON MARINE a J ` ' Spacing i Hang down height:1.71" m PLANS k i 0 ' = 19"or 23"Racking available ° Width:28.46" (7' Useable Height • Depth:36.67" Usable racking height has been revised Handles #3 ® 12" EACH WAY 61405 MAIN ROAD to only fit in the opening of the door jam ° Protrude 2.2" - a which Is cabinet height minus 4.25" Total Space Occupied SOUTHOLD, NY 11971 0 Maximum:74.25 • Height:78,855" CONCRETE PAD Number of rack units per rail set:42 Width:211 (CAST-IN-PLACE SUFFOLK COUNTY OR PRE CAST} Total number RU's:Up to 84* . Depth:37.75" NOT F +r Useable Depth A> Maximum:30.5" Minimum:28.75" SITE TYPE: = 1. USE GALVANIZED HILTI EXPANSION ANCHORS OR, 150'-0" CONCEALMENT POLE b APPROVED EQUAL, FOR EQUIPMENT ANCHORAGE. 2. FOR SIZE AND LOCATION OF ANCHORS AND OTHER REQUIREMENT, SEE EQUIPMENT VENDOR DRAWINGS. Top 74.75"-78.23"Ntiv__-. 3.25" -Yv _v.30.50" M.�' COPYRIGHT©2021,AZIMUTH ENGINEERING P.C.,LLC ALL t RIGHTS RESERVED 74.57 74.75" 18" 29,50" 3. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF TI-+IS DRAWING AND ALL THE INFORMArioN CONTAINED HEREIN Is AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHO.',l THE 90 4000 PSI. WOR!; WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. THIS O 45.00"-74.57" 29.57" 30.50" - DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, „ _.__...... .. »__.. ._..- DISTRIBUTED OR RELIED UPON FOR ANY OTHER PURPOSE > Center 33,00"-45.00" 12.00" 28,75" WITHOUT THE T of Az!MLTH EXPRESS V'/KITTEN COdSEN II , .--_..-._.,.-_., .__ .. __..., ......... ......_.....__.. _.__.._.,M.._...�.____.._-_,.__.._- ._...,._.__......_._._ - ENGINEERING P.C., LLC. o I 3.43"-33.00" 29.57" 30,50" SHEET 11rLF w *Front and Rear sets of rails allow some 3,25"-3.43" .18" 29.50" equipment to rack both directions providing Bottom 0,00"-3.25" 3.25" 30.50" Q up to 84 RU _-.-. ._ .____ FIRE DISTRICT EQUIPMENT Z 0 cn GHEE 1 fIUMBER: EL LLJ 3 0D-78DDC FIRE DISTRICT OUTDOOR ENCLOSURE DETAIL 4 OUTDOOR PAD FOR FD. CABINET 5 NOT USED Z-16 NOTES TO USERS This map is for Use in administering the National Flood insurance Program. It ISLAND [does not necessarily identify all areas subject to flooding, particularly from local ZONE VE N e sources of small size. The community map repository should be �'��'���� ZONE X ZINE X ZONE� Ilial SPECIAL FLOOD HAZARD AREAS SUBJECT TO INUNDATIONdrains g ZONE 1430000 FT 72 2210" BY THE 1%ANNUAL CHANCE FLOOD e additional flood hazard information. JOINS PANEL 0157 ,r ��'Qs'37.5" consulted far possible updated add 1425000 FT The i%artnliaf flood(iso-year flncxl),also krxwvn as 1 base Road,is the flood ttxnt ftias a 10Aa 72'24'22.5" chance of bei n9 sxaualed or exceeded in any given year, The,Special Fiopd Hazard Area is the ' � To obtain more detailed information in areas where Base Flood Elevations l I i Ii I as, ff ., n � •, ,: ' .�� :,�,,•..� :. .� II p II ! III I � area subject to flooding � tip 11annual ai chance flood, Areas of S al Flood Haard include (BFEs)and/or floodwayshave been determined users are encouraged to cos ZONE loner A, fie, Al aCAP, , Vand VE The Base Flood Elevation is thexatar surface Et#s elevation of the 114 amyl chance Hood. c� the Flood Profilesand Flaadway Data andfor Summary of Stillwater Elevations tables contained within the Flood Study (FIS) report that accompanies CORPORATE LIMITS ZONzOne a NNa Base Flood Eleyatfons detcmti Cd. this FIRM: Users sfouid be aware that 3FEs shown on the FIRM represent ZONE AE M � .. roundedwhole-foot elevations, These BFEs are intended for food insurance COINCIDENT WITH SHORELINE JE Bas�GoodEeva4o>s�e�rmrned, r. sole source of flood } ENC 4 1 ratingpurposes only and should not be used as the , . .,. p P ,�«,..:w ;;u ZONE AH Flood depths of 2 to fit (usually areas of rti Base Flood • � elevatitan information, Accordingly, flood elevation data presented in the i5 ZINE X t, t,4 i3e✓atmnsdetermir>eci, b g i conjunction with the FIRM for purposes of .NE YE report should be utilized in a } p p p y.A t L 1 ZONE AO Flood:depths of 1 to 3 f � . r u,o , � ZO,IVE X aEt:.a) = , . .-,. ,. ,k,� ,, ,• , p �(usually sheet flo',+r an sloortxi terrain);averse construction and/orfloodplain management. � dIl I't lli�� �. .INE AE ' '•'� .<NE,X •:,; depths determnneii. For areas of alluvtaf fan flooding, ve[ociltie5 also 9 � Y — at ase' Flood Elevations BFEs shown on this map apply only 2DtaE AR Special Mood Ii�ard Area formerly protected from the 1: annus[cur � , , f '� t�: , � E„,'77,7 Y p °�o chance («�` 8 Users of this EL9 , landward of 0.0 North American Vertical Data of 1988 (NAND 8i. {, } III 1 : , ., ,�', ,,. food w-�-.- i the ,it ' by a flood control system that Was sequerrtlydeae,Ufir:I: Zone AR ,..,. t� flood elevations are. also provided n h ,`: <,�,° ,, �` ' ° ^ irxlitates that f t FIRM should be aware that Coss I? ” ,, t the Dimer load ccntml system is being restored to provide Summary of Stillwater Elevations and Transect Data tables an the "food Insurance ZONEAE � . . proteetlorn from the 1%annual_nonce or greater floor. ELIT LP Study report for this }uilad€cttan. Elevations shown In the Summary of Stillwater � zOr�Ass Area to fr � Mr�elc>SsC�rmnirinuca€ionslhfrastructrtr r•-�r=its Elevations and Transect Data tables should be used for construction and/or - ,. be protected eNn 1°/a annual dtante flood W a Federal flood 9 ,• ,� �Kt ; `�te�r `: prptzdron systr»m under construction; no Base* FloatF1eaeticros ' floodplain management purposes when they are higher than the elevations shown r ?�a a a°�f, determined, on this FIRM. R.`f .rt >> *` N {EL _ 52 N - - t 6 r s.. It ' t. a ' �� k^:f''+ - x° L�X0236n �Ir• -. x NE v Coastal flood zone aaifls velocity i7azard (wave a,don),, no base Flood El i c Boundaries of the floodwa s were computed at cross sections and interpolated t7NE - • ' � E. , .. . ,". .•, , . .' . ,, � �� �:, � �;�o c1 , , . EL 8: s zt}t�.lE VE Coastal Hood zor with hazard �^ between cross sections, The fGcadways were based on hydraulic considerations � t velocity azo d (ava+� action), Base Flood 340000 FTwith regard to requirements of the National Flood insurance Program. Floodway u ': � LB�RT5C3NLA'NE �xj4 � �. �,L F :;:_ l3rvationsdetermined. ,: widths and other pertinent tloodway data are provided in the Flood Insurance A I . » - � FLCIODWAY AREAS IN ZONE AE z ' Study report for this jurisdiction, r ,» �� _, � •, <.. i must be Iet free ; N The loodr^ra� is the ehannei of a stream us an adjacent flood afro areasthat of encroachment so that the 1%anncet chane flood can be carded without substantial increases Certain areas not in Special Flood Hazard Areas may be protected by flood « ," ` ' Z4E control structures, Refer to Section 2,4 "Flood Protection Measures" of the �`,� � � } IIS I� ,� I � �"��"I�I i i "�I in flood h@iglitS. , Flood Insurance Study report for information on flood control structures for this . .�a , � >._, ,- '! , OTHER FLOOD AREAS � • jurisdiction. .: ZONE X Areas of i},2%annual chance flood;areas of 1%annual chance food with average depths of fess than 1 foot or with drainage areas less than The projection used [n the preparation of this map was New York Stale Plane �, t square mile;and areas irotected by levees Irom 11r annual dance Fiood p 3 MIT F M T I y FIPSZONE 3104, The horizontal datum was NAD 83, GRS80 spheroid. Z0NE.X Differences in datum, spheroid, projection or State Plane zones used in the OT EA I'iER AREAS production of FIRMS for adjacent jurisdictions may result in slight positional differences in map features across jurisdiction boundaries, These differences do '.: zone x Meas d�emiirTed to be outside the 0.2%annual chance tlopdplain. ZONED teras In which flood hazards are undetermined,but possble, not affect the accuracy of this FIRM, i - n To''4T'[t IB Flood elevations on this map are referenced to the North American Vertical Datum su ; - COASTAL BARRIER RESOURCES SYSTEM(CBRS)AREAS of 1988. These flmori elevations must be compared to structure and ground � � °�°6vith 3ld OTHERWISE PROTECTED AREAS(OPAS) elevations referenced to the same vertical datum. For information regardingS'�t conversion betyveen the National Geodetic Vertical Datum of 1929 and they North American Vertical Datum of 3388,. visit the National Geodetic Survey CP.RSareasandCPAsarenoamalfyixatedwittvhoradjacerrttc,SpeeialFloodHazarziAreas, website at htto:/lwww ngs.ncaa,gov or contact the National Geodetic Survey at r' m 10%annual chance floodplain boundary izo the following address: {3NE VE ,. 0.2%annual chan€efloodplainboundary NGS Information Services � 8'* ' ♦N I F ♦ Flocdnay boundary NOAA.NiNGS12 Zone D boundary National Geodetic Survey i• •i1#MiCISand CPA boundary tkiySSC-3,#9204 LYZ) PROTECT YOURSELF 1315 East-West Highway Boundary dividing „u ily�edal Flood• Hazard Area Zones ant�� �3-nLarydl vding SpeddFlaad f3ldttRteaS.Od fferent Base , ALL STATES REQUIRE NOTIFICATIONION F EXCAVATORS, DESIGNERS; OR ANY PERSON NSilver Spring,Maryland 20910 3162 " : •:." -_' `,'T'Tfi' l!lull l-+l f F,l4'i +TE `P±T (301)7't3-3242 Flood Elevations,flood depths or flood velocities.: -..�1a PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN ANY STATE r' w ',1a�',I� ItL'AVE#AGTIQN _' ., � �•r � ,. C?rNE,!AE, s�rs5 <>m - r--.LlnitafNkdzratevavepttion To obtain current eievaitan, description, and/or Location information for bench ZONE VE KnowwhatsbelOW. marks shown on this ma lease contact elle Information Services Branch � `� yt, ,a ill`8i •, .�.�513«w Base Flood Elevation line and value'elevation in feet p= p t. � �, '" - � , _� Cal before you dig. ` r e at 301 7'{3-3242. or visit its website at n;_ ., .-. �, ,,. ,. r ,, , , �, of the I',la#tanal Geodetic Survey ( � .� ; ��, fry � r, �`, FL 987 BastllocdElevaUpnvaluewha,reunifolmwithinzorr.� elevation FOR STATE SPECIFIC DIRECT PHONE NUMBERS http://www,ngs.noaa,govr. s '; K ! a x Y}, � a , 1 e , l in feet* �,. VISIT: WVdW.CAI.181T.COM information shown on this FIRM Was provided in digital format the � w „; � A� Referenced to the North American Vertical Datum of 1988 Pp- Base map f p g by ra New York State Office mf Cyber Security and Critical Infrastructure Coordination « r: , �. N �a} '-- .Cross sKttan lne T DRAWN B1. CHCKEY This information was derived from digital ortho hoto9rap Y produced at a 1,040ot AS SHOWN WAS KM pixel resolution from photography dated 2004. TLimited BetaI a s onli� a.r r F w � *w a ,, ,. �• � .,,:: , , ,. .... �>�° ,.•, xa s Transect line o updated topographic information, this map reflects more detailed and Based n pp ,, , h ---- ---- - ZONEAE _ ..a , ... � _ ZC}NE VE f �, --- ---- ---- those y , r �,. .., : ,.. �.. IiIG coordinates referenced to the North American Datum stream channel configurations and floodplain delineations than �c _„ �, . . ,o .. ,-� ,pz , . �. � 87 0745 ,32 2230 �� up-to-date 5t ft el � f� : a: . `C . .;,. , • } V . ' v cf l cM(NAD 83),Western Hemispiri re ttlose shown oil the previous FIRM for this jurisdiction. As a result, the Flood ,r � r, ;._.�;. � , „��«-�� _ , lE 7, � �„ Profiles and Floodway Data tables for the Nrtheast Branch Nlsse u_o ue River 1n as v :i• .: st• .:: i. Y. .. ,1 x -• I '`^` '76""N 14�-r�etrn Vuuersa)Tia Mercator values,done 1s, ---- the Flood Insurance Study Report!which contains authoritative h drautadatal may --•- ---- ---- >. a ,.. 0 12/23/21 ISSUED FOR FILING WP ,.x., ,: 0 �•- «f ,:< t :, '~ -J 600000 FT 5000-foot grid valves.skkatename State Plane coordinate K �WS reflect stream channel distances ilia#differ from what is shown an this Wisp. Also. u3 >, ;,; a. , r,,;, W s. x nz FIPS?ONE rt ozone s lizrename projection the road to floodplain relationships for unrevised strearns may differ from what is a �� „, „ � �stzm,spa t p ), p p i shown on previous(naps. «'* a E 10/15/21 REVISED PER COMMENTS GJB f WS lT p D?t5810, Bench mark ( explanation in Notes to Users section of this «` ." ;'• " „ Z FIRM panel) D 05/12/21 REVISED PER COMMENTS WA$ WS Corporate limits shown oil this map are based an the best data available at the d ,¢ 4��a /"fl G'��`., t p, pt g s or de-annexations may rn •' 1 ' §, 0 M1.5 River Mile have ooccurred afterthismap was published,map users contact appropriate ,«;� a :" ,ZC3NE U C 05/03/21 REVISED PER COMMENTS WAS f WS .„. community officials to verify current corporate limit locations. 0 o� � � 1, «. gruPiFErsITCRY p r B 04 I REVISED PER COMMENTS Please refer to the separately printed Ma index for an overview map showing zNAE d /29/2 WAS JWS Ref�rtcis[In afP�la Repositories ltidax I p y P R 9 �"`t'ao�a'(ELs)6.; CB arttaaI the layout of map panels for this jurisdiction, pa,- ABLi HEQ 11-i - � EFFEC71VEDM7EOFCOUN7YVv1DE A 04/06/21 ISSUED FOR REVIEW WAS f WS FLOOD INSURANCE RATE fvlAP as SEE B LEGENQ� The AE zoite category has been divided by a Limit of Moderate Wave Action Zt;} lEAE .� , * NE E {1St 7=y, • May 4,199f DRAWN CHECKED I_iMVJA : The LiLti'WA represents the approximate landward limit of the 1.5-foot S Ede r F ESE REV DATE DESCRIPTION BY BY EFFECTIVE DATE(S)OF FtEV151i]N($1 TC}THIS PANEL ( D C ) xK WA TI # El 7} breaking wave.The effects of wave hazards..between the VE.Zane and the LiMWA t°. wy�a .. ,.s September 26 2009-to change zone designations,to reflect revised shoreline to change Special Flood Hazard Areas,to update the effects of wave action,to incorporate Primary i (air between the shoreline and the LlMlftrA for areas where VE Zones are not ,� » �, Frontal Dune analysis,to reflect the effects of coastal erosion,to change Base Flood r Elevations,to update map format,and 10 reflect updated topographic information identified)wit[be sirliilarto,but less severe than those in the VE Zone; "" 335000 FT MIT(}F MODERATE Contact the FEMA Map Service Center at 1-800-358-9616 for information on ZONIE AE AVE GT1bN 14„ rzx available: products associated With this FIRM: Available products may include previously issued Letters of Map Change, a Flood Insurance Study report, and/or To determine if flood insurance is available in this community,contact your-insurance digital versions ofrth s map, The FEMA Map Service Center may also be reached I#UDD. a,ynt,x call the National Flood Insurance Program at 1.800-638-6620. ,C by Fax at t-800-358-9620 and its website at http:/Imsc.fema.gov. F If you have questions about this reap or questions concerning the National Flood N. \r�rjr, � :t Insurance Program in general„please call 1.877 FEMA MAP (1-877-336-2627) or MAP SCALE 1" 500" y 5'r '• � Y�l (� visit the FEMA website athttp 1wwwfema.goy/business/tifig. LOCATION OF PROPOSED WORK = t` 250 0 500 100FEET ���� �p slbc ��.. 09 �, METERS COASTAL BARRIER RESOURCES Iso 0 150 300 SYSTEM (CBRS) LEGEND ' Alf k L 4550Q:0"N JERE K McKEON 1001-193 CSRS Area ZONE �� � , I ( D PANEL 0159H NEW Y ,. LICENSED PROFESSIONAL FLOOD INSURANCE NOT AVAILABLE FOR STRUCTURES NEWLY BUILT"OR �: � E��:fi�s�l'. ENGINEER- LICENSE NUMBER:095374-I SUBSTANTIALLY I MPR'OVED ON OR AFTER OCTOBER 1,1983, INDESIGNATED F jFIRM CBRS ALAS. r r T IS A VIOLATION OF LAW FOR ANY PERSON, 11-18-1990 GI3RSAirea { ` t FLOOD INSURANCE RATE MAP UNLESS THEY ARE ACTING UNDER THE DIRECTION m OF THE RESPONSIBLE LICENSED PROFESSIONAL FLOOD INSURANCE NOT AVAILABLE FOR STRUCTURES NEWLY BUiLT OR ��� �$ ' , v , SUBSTANTIALLYIMPROVEDONORAFTER NOVEMBER 16,1990, IN ENGINEER, TO ALTER THIS DOCUMENT. DESIGNATED CBS AREAS. ����4 ��, (A atJURISD JURISDICTIONS) N)=1f��Ol�ft (AL1.JURISDIGTiC3N5) 11-16-1991 Otherwise Protected Area(OPA) y r CONTAiNS: SITE � N F O R I V I A I I 0 I TI j FLOOD INSURANCE NOT AVAILABLE FOR STRUCTURES NEWLY BUIf_TOR « SUBSTANTIALLY IMPROVED ON OR AFTER NOVEMBER 16,1991 IN I � ��MM��i�Y NUMBER i DESIGNATED OPAsWTHIN THE CBRS. SHELTER ISLAND, 364809 ' SITE NO: ALBERTSON MARINE 11-15.1993 CSRS Area TOWN OF FLOOD INSURANCE NOT AVAILABLE FOR STRUCTURES NEWLY SUILT OR J SOUTHOLD,TOWN OF 360813 SUBSTANTIALLY I MPROVED ON OR AFTER NOVEMBER 15,1993 1N 61405 MAIN ROAD DESIGNATED CBRS AREAS. � � � SOUDIOLD, NY 11971 11-15-1993 Otherwise Protected Area(OPA) , NOTE= THIS URO ti�Ict.uoesM tTAaOs D rise THE aA��lTAL SUFFOLK COUNTY FLOOD INSURANCE NOT AVAILABLE FOR STRUCTURES NEWLY BUILT OR RARRIEA ea SYSTEM eA Tn'Or ANUNDER 11T U co FNT SUBSTANTIALLY I MPROVED ON OR AFTER NOVEMBER 15, 1993 IN ENABLINt EsoURTIO ACT tar tsa2 Air +oR s€iasscatsetuT DESIGNATED CPAs WTHIN THE CBRS. Erwstlf4G t EGISi?rioN 02-24-1997 CBMAP SUFFFIX. H RS Area PANEL OF 1q�26 SITE TYPE � F ' FLOOD INSURANCE f,OT AVAILABLE FOR:STRUCTURES NEWLY BUILT OR (,SEE MAP INDEX:.FOR FIRM PANEL LCY+OUT1 150'^0" CONCEALMENT POLE SUBSTANTIALLY i MPPOVED ON OR AFTER FEBRUARY 24,1997 IN I DESIGNATED CBRS AREA'S. Notice to User: The Map Number shown below should be used when placing map orders, the Community Number Boundaries of the John H.Ohafee Coastal Barrier Resources System shown above should be used on insurance applications for the (CE IR )shown on this FIRM were transferred from the official CSRS Subject community source map(s)for this area and are depicted on this FIRM for COPYRIGHT©2021,AZIMUTH ENGINEERING P.C.,LLC ALL informational purposes only. The official CEIRS(naps are enacted by I VIN T� MAP NUMBER RIGHTS RESERVED C'r' Corft�re$S Vla the GQaStal Barrier ReSt7urceS Act,as arnPrlded,and Q�--^ }-IIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS �� p 36103CO159M AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE maintained by the U.S.Fish and Wildlife Service(HWS). The official 41"f}3'45" WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. THIS O CBRS maps,used todetermine whether or not an area is located within _ v20""'E 72"`22'30" �n� DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, the CBRS are available for download at http.flwww.fws.gov. For an aF,O�. y, F19 � E JOII''luS' PANEL 0167 u1L✓ Q� �� � p�� ry DISTRIBUTED OR RELIED UPON FOR ANY OTHER PURPOSE > official determination of whether or not an area is located within the 18"4" ( ,ICVt7 s { MAP REVISED WITHOUT THE EXPRESS WRITTEN CONSENT OF AZIMUTH � CEIRS,or for any questions regarding the CBRS,please contact the FWS 72-24'22.6" SEPTEMBER 25,20{l9 ENGINEERING P.0 LLC.o field office for this area at{537}776-1401. I „� wFederal Emergency Management Agency EF-i TITLE_ z 2007 FLOOD INSURANCE ----- -— _ _ _ -- RATE MAP z 0 Cn 71�ET DUMB F ►7 C2 ��� /� ����� ������� TE � GRAPHIC SCALE 4 z 0 4 S SCALE: 1/4" = F-0"FOR 22"x34"DRAWINGS Z-17 J (IN FEET) SCALE. 1/8" = 1'-0"FOR 11"x17"DRAWINGS Q u SITE INFORMATION PROJECT DIRECTORY rs , PROPERTY OWNER: BUDD'S POND ARENA APPLICANT: DISH Wireless LLC L.L.C. ; ADDRESS: 61405 MAIN ROAD, ROUTE 25 5701 SOUTH SANTA FE DRIVE SOUTHOLD, NY 11971 LITTLETON, CO 80120 TOWER TYPE: CONCEALMENT POLE TOWER OWNER: TBD TM L L C TOWER CO SITE ID: TBD SITE DESIGNER: AZIMUTH ENGINEERING P.C. 5701 SOUTH SANTA FE DRIVE SCOPE OF WORK TOWER APP NUMBER: TBD 695 ROUTE 46 WEST, SUITE 300 LITTLETON, CO 80120 FAIRFIELD, NJ 07004 0 THIS IS NOT AN ALL INCLUSIVE UST. CONTRACTOR SHALL UTILIZE SPECIFIED EQUIPMENT PART OR ENGINEER COUNTY: SUFFOLK APPROVED EQUIVALENT. CONTRACTOR SHALL VERIFY ALL NEEDED EQUIPMENT TO PROVIDE A FUNCTIONAL SITE. 000 r W67 THE PROJECT GENERALLY CONSISTS OF THE FOLLOWING: LATITUDE (NAD 83): 41.076046' TM TOWER SCOPE OF WORK: SITE ACQUISITION: CENTERLINE • INSTALL (3) PROPOSED PANEL ANTENNAS (1 PER SECTOR) LONGITUDE (NAD 83): -72.406043' LORNA MOND • INSTALL (3) PROPOSED ANTENNA MOUNTING FRAMES • INSTALL PROPOSED JUMPERS (516)557-2398 • INSTALL (12) PROPOSED 7/8" COAX CABLES (4 PER SECTOR) AND (1) RET CABLE ZONING JURISDICTION: TOWN OF SOUTHOLD DISH Wireless LLC L.L.C. SITE I D: INSTALL (6) PROPOSED DIPLEXERS CONSTRUCTIONMANAGER.• M LADEN ZAIMOV M 'NZIM TH GROUND SCOPE OF WORK: ZONING DISTRICT: M-II - MARINE II (201)496-9271 � ... • INSTALL (6) PROPOSED RRUs (2 PER SECTOR) Am • INSTALL (1) PROPOSED OVER VOLTAGE PROTECTION DEVICE (OVP) • INSTALL (6) PROPOSED DIPLEXERS BLOCK/LOT: 3 / 15 RF ENGINEER: IMAD MEMON • INSTALL (1) PROPOSED METAL PLATFORM 695 ROUTE 46 WEST, SUITE 300 INSTALL (1) PROPOSED ICE BRIDGE OFFICE: (303)706-4019 FAIRFIELD, NJ 07004 • DISH Wireless LLC L.L.C. SITE ADDRESS: INSTALL (1) PROPOSED PPC CABINET OCCUPANCY GROUP: TBD MOBILE: (551)204-4483 INSTALL (1) PROPOSED EQUIPMENT CABINET • INSTALL (1) PROPOSED POWER CONDUIT CONSTRUCTION TYPE: TBD INSTALL (1) PROPOSED TELCO CONDUIT 145 05m MA I N R OA D 0 U T E ;'o met- 5 • INSTALL (1) PROPOSED TELCO-FIBER BOX �0 MCC;KF 9 INSTALL (1) PROPOSED GPS UNIT POWER COMPANY: PSE&G / UPA • INSTALL (1) PROPOSED SAFETY SWITCH (IF REQUIRED) e� INSTALL (1) PROPOSED FIBER NID (IF REQUIRED)U10LUq NY W 11971 INSTALL (1) PROPOSED METER SOCKET TELEPHONE COMPANY: VERIZON ` 4t .r 'r I • INSTALL (1) PROPOSED H-FRAME z FLSF NEW YORK CODE COMPLIANCE SITE PHOTO DIRECTIONS °PRUFESS� ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF DIRECTIONS 3 ADP BLVD, ROSELAND, NJ 07068: THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO Depart and head toward Adp Blvd/Turn left onto Adp Blvd/Turn right onto Choctaw Way/Turn right onto / BE CON'S'TRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: Livingston Ave / County Hwy-527/Take the ramp on the right and follow signs for 1-280 East/Take the � IEREMY K McKEON CODE romp on the left for 1-95 N / New Jersey Tpke N/Take the romp on the right for US-46 and head toward NEW YORK LICENSED PROFESSIONAL Palisades Park / The Ridgefieids/Keep straight to get onto ramp/Kaep left to get onto ramp/Keep straight ENGINEER- LICENSE NUMBER: 095374-1 MECHANICAL 2018 IBC to et onto US-46 E US Highway 46 Kee straight to et onto US-1 N US-46 E US-9 MECHANICAL 2018 IMC 9 / 9 Y / P 9 9 / / N / US ELECTRICAL 2017 NEC Highway 46/Take the romp on the left for 1-95 North / US-1 North / US-9 North and head toward G TELECOMMUNICATIONS TIA 607 Washington Bridge/Entering New York/At Exit 69, gear right onto 1-295 S / Cross Bronx Expy E toward R IS A VIOLATION OF LAW FOR ANY PERSON, Thros Neck Br 1-295 South At Exit 8, head on the ram right and follow signs for Cross Is Pk S UNLESS THEY ARE ACTING UNDER THE DIRECTION 9 / / P 9 9 Pkwy OF A LICENSED PROFESSIONAL ENGINEER, At Exit 30E, head right on the ramp for 1-495 East toward Eastem Long Is/Keep left to get TO ALTER THIS DOCUMENT. onto/ramp/Marge onto 1-495 E / Long Island Expy E/At Exit 73, head left on the romp for County Hwy-58 toward Greenport / Orient/Keep straight to get onto romp/Merge onto Old Country Rd/At the roundabout, DRAWN BY: CHECKED BY: APPROVED BY: S H E E T I N D E X take the 2nd exit/Continue on NY-25 / Main Rd/Pass Harbes Farms Jamesport in 3.0 mi/Turn left onto Wickham Ave/Turn right onto County Route 48/Road name changes to County Road 48/Turn right onto MDC JAA J K M Hortons Ln, then immediately turn left onto NY-25 / Main Rd/Arrive at 4Y-25 / Main Rd SHEET NO. SHEET TITLE RFDS REV #: 3 T-1 TITLE SHEET TO B PROVIDED PRELIMINARY A-1 OVERALL SITE PLAN do COMPOUND PLAN DOCUMENTS A-2 ELEVATION, ANTENNA LAYOUT AND SCHEDULE VICINITY M A P A-3 EQUIPMENT PLATFORM AND H-FRAME DETAILS SUBMITTALS rx REV DATE DESCRIPTION A-4 EQUIPMENT DETAILS - A 08-23-21 ntnvu, sulmiSSIoN A-5 EQUIPMENT DETAILS °` 0 0e-20-21 IMED FOR PEMMr A-6 EQUIPMENT DETAILS t t t-03-21 rssu:D FON PEWI 2 11-30-21 ISSU® FOR PoWff E-1 ELECTRICAL/FIBER ROUTE PLAN AND NOTES E-2 ELECTRICAL DETAILS AND RISER DIAGRAM E-3 ELECTRICAL ONE-UNE, FAULT CALCS do PANEL SCHEDULE $,at.7h:ee Clrie UNDERGROUND SERVICE ALERT - NEW YORK 811 SITE LOCATION y:,,f �$ A&E PROJECT NUMBER G-1 GROUNDING PLANS AND NOTES UTILITY NOTIFICATION CENTER OF NEW YORK F.= ; �fE!Tmt! �n� • tipsy nintRestaurant,yj NYNYCO2239A G-2 GROUNDING DETAILS (800) 272-4480 G-3 GROUNDING DETAILS WWW.NEWYORK-811.COM :` T`4• ' : e '*� r,� nor"Su`tes� s ' DISH WIRELESS PROJECT INFORMATION CALL 2 WOMM DAYS UnumY NOnFIC TM PRIOR TO CONSTMXIaN M - N Y N YC 0 2 2 3 9 A RF-'I RF CABLE COLOR CODE Albertson Marine,Inc. zs ' :: .. YfJ � a�� 61405 MAIN ROAD, ROUTE 25 GN-' LEGEND AND ABBREVIATIONS GENERAL NOTES "� �L SOUTHOLD, NY 11971 GN-2 GENERAL NOTES `� GN-3 GENERAL NOTES GN-4 GENERAL NOTES THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED3 F ' # zs FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT 014 DRAINAGE. NO SANITARY SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SHEET TITLE SIGNAGE IS PROPOSED. - `' TITLE SHEET ° 11"x17" PLOT WILL BE HALF SCALE UNLESS OTHERWISE NOTED . ` :, ,b�� = r. SHEET NUMBER CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS, AND CONDITIONS ON THE JOB SITE, AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE T=1 PROCEEDING WITH THE WORK. NO SCALE DISH Wireless L.L.C. TEMPLATE VERSION 34 - 06/11/2021 NOTES NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2. ANTENNAS AND MOUNTS OMITTED FOR CLARITY. 2. CONTRACTOR SHALL MAINTAIN A 10'-0" MINIMUM SEPARATION BETWEEN THE PROPOSED GPS UNIT, TRANSMITTING ANTENNAS AND EXISTING GPS UNITS. 1 WOODAD 3. ANTENNAS AND MOUNTS OMITTED FOR CLARITY. A-2 .j ,. LLC EXISTING RAILROAD 5701 SOUTH SANTA FE DRIVE TRACKS (TYP) LITTLETON, CO 80120 SEE COMPOUND PLAN (SHEET A-1/DETAIL 2) 1 PROPOSED DISH Wireless EXISTING TRANSFORMER BUILDING �TYP) EXISTING LLC HYBRID CABLE ROUTED � ALONG ICE BRIDGE EXISTING UTILITY H-FRAME PROPOSED DISH Wireless LLC EXISTING MESA /XZIM fk PROPOSED 10'-0~x10'-0" 12" WIDE ICE BRIDGE CABINET 1 DISH Wireless LLC LLC (37'-0" ICE BRIDGE LENGTH) 4I6 •. ? > 1 x ® ; , EXISTING FIRE DEPARTMENT LEASE AREA - EQUIPMENT CABINET ON 0 SEE EQUIPMENT CONCRETE PAD 695 ROUTE 46 WEST, 1 1 SUITE LAYOUT (SHEET A-3) EXISTING FIRE DEPARTMENT FAIRFIELD, NJ 07004 300 1 ICE BRIDGE 5'-6" 5'-4" EXISTING 150'-0" '`s CONCEALMENT TOWER x x x x —X—X x x x x x x x x x x x x x x x x x /` Ynq 7 F- CIO)M I r I Lu cr w O 2 a GRASS No. AREA i _ L_ , I o 0 I I I x NSF PROFE`'S\O x is CC o T7 I I 7'-0~ , f— , i �EMY McKEON c� I PLATFORM I I 1 NEW YORK-10ENSED PROFESSIONAL z ____ I ENGINEER- LICENSE NUMBER:095374-1 X Ld IT IS A VIOLATION OF LAW FOR ANY PERSON, I UNLESS THEY ARE ACTING UNDER THE DIRECTION LICENSED PROFESSIONAL ENGINEER, `n OOF A v 23 -11 I I \� TO ALTER THIS DOCUMENT. � x r -H I I ' MAIN ROAD ° •_____ _____�� � DRAWN BY: CHECKED BY: APPROVED BY: xA111 I "NI I x x—� MDC JAA JKM xrrx RFDS REV #: 3 x II x EXISTING PAVED flill-m-W 11 PRELIMINARY x PARKING LOT (TYP) x14444111 1111d DOCUMENTS EXISTING TREE LINE (TYP) x x ALS x x x x x x x x x x x x x x x x x x x x x x x x x x� REV DATE DESCRIPTION t70'-2" EXISTING A 05-23-21 INMAL SCISSION COMPOUND Q 09-20-21 SUED FOR FERk!!T SEE ANTENNA LAYOUT EXISTING CHAIN LINK (SHEET A-2) FENCE (TYP) 1 11-05-21 ISSUED FOR P£RMrr EXISTING VERIZON EXISTING FUTURE EXISTING ACCESS 2 11-30-21 ISSUED FOR POW EQUIPMENT PLATFORM CARRIER AREA (TYP) GATE EXISTING VERIZON ICE BRIDGE A&E PROJECT NUMBER NYNYCO2239A DISH WIRELESS PROJECT INFORMATION NYNYCO2239A 61405 MAIN ROAD, ROUTE 25 SOUTHOLD, NY 11971 SHEET TITLE OVERALL SITE PLAN & COMPOUND PLAN SHEET NUMBER 60' 30' 0 60' 120' 6' 4' 2' 0 5' 10' Awl OVERALL SITE PLAN COMPOUND PLAN 2 1$'=600 3/16"=1'-0" DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 NOTES 1. CONTRACTOR. SHALL FIELD VERIFY ALL DIMENSIONS. 2. ANTENNA AND MW DISH SPECIFICATIONS REFER TO ANTENNA SCHEDULE AND TO FINAL CONSTRUCTION RFDS FOR ALL RF DETAILS EXISTING FIRE DEPARTMENT WHIP ANTENNA TOP EL. @ 164'-10" AGL LLC (6) PROPOSED DISH Wireless LLC EXISTING FIRE DIPLEXERS MOUNTED BELOW PROPOSED ANTENNAS INSIDE EXISTING DEPARTMENT ANTENNAS CONCEALMENT POLE 5701 SOUTH SANTA FE DRIVE AND EQUIPMENT LITTLETON, CO 80120 EXISTING VERIZON ANTENNAS �`rF�+ PROPOSED DISH Wireless LLC ANTENNA RAD CENTER @ 146'-10" AGL 01 (TYP 1 PER SECTOR, TOTAL 3) EXISTING 150'-0" EXISTING VERIZON ANTENNAS EXISTINGA RAD CENTER @ 141'-2" AGL MULTI SECTION, CONCEALMENT POLE MULTI—SIDED CONCEALMENT POLE C1 S��pR EXISTING VERIZON PANEL �o'sw�d►� --- --1 ANTENNAS (TYP) '1� 1 I 1 1 3 PROPOSED DISH Wireless LLC L.L.C. ANTENNAS Al RAD CENTER ® 130'-0" AGL ® ® INAUTH FUTURE CARRIER ANTENNAS I I RAD CENTER @ 118'-0" AGL ° a 695 ROUTE 46 WEST, SUITE 300 SEE ANTENNA LAYOUT E FAIRFIELD, NJ 07004 (SHEET A-2/DETAIL 2) I I FUTURE CARRIER ANTENNAS EXISTING 6"0 MAIN PIPE C I RAD CENTER @ 106'-0" AGL MAST (FIELD VERIFY MAST PROPOSED DISH Wireless LLC MOUNT I I SIZE PRIOR TO (TYP 1 PER SECTOR, TOTAL 3) iq I Ir" CONSTRUCTION) B1 I EXISTING CANISTER SECTION C'O&ao (TYP) I FUTURE CARRIER ANTENNAS y 0% I RAD CENTER @ 94'-0" AGL I Ip C� fijui I FUTURE CARRIER ANTENNAS * r I RAD CENTER @ 82'-0" AGL ERE 9y � N I NEW Y K LICE OFESSIONAL ENGINEER- LICENSE NUMBER:095374-1 it IT IS A VIOLATION OF LAW FOR ANY PERSON, II UNLESS THEY ARE ACTING UNDER THE DIRECTION II OF A LICENSED PROFESSIONAL ENGINEER, II TO ALTER THIS DOCUMENT. II (1) PROPOSED DISH Wireless LLC II DRAWN BY: CHECKED BY: APPROVED BY: 12" 6" 0 1' 2' 3' 4' S' RET CABLE ROUTED UP WITHIN II ANTENNA LAYOUT 2 MDC JAA JKM EXISTING CONCEALMENT POLE l I II ANTENNA TRANSMISSION CABLE RFDS REV #: 3 (12) PROPOSED DISH Wireless LLC e COAX CABLES ROUTED UP WITHIN II SECTOR POSITION EXISTING OR MANUFACTURER — MODEL RAD FEED UNE TYPE PRELIMINARY EXISTING CONCEALMENT POLE �I PROPOSED NUMBER TECHNOLOGY SIZE (HxW) AZIMUTH CENTER AND LENGTH li DOCUMENTS I (4) 7/8" COAX II ALPHA Al PROPOSED COMMSCOPE — FW-65B—R3 5G 1.9" X 11.81 70' 130 -0" (160 LONG) SUBMITTALS II II REV DATE DESCRIPTION II (1) PROPOSED DISH Wireless A 08-2$-21 INITW. S'UBId:'SSSON it LLC HYBRID CABLE ROUTED II ALONG ICE BRIDGE " COAX 0 09-20i-21 ISSUED FOR PEW �I PROPOSED DISH Wireless LLC BETA B1 PROPOSED COMMSCOPE — FW-65B—R3 5G 1.9" X 11.81 190' 130'-0" ((160' LONG) t 11-05-21 ISSUM FOR PERk#T it 12" WIDE ICE BRIDGE it (37'-0" ICE BRIDGE LENGTH) 2 11-30-21 ISSUED FOR PERIdIT EXISTING V ICE II EXISTING FIRE DEPARTMENT EQUIPMENT BRIDGEIDGE (TYP) I� CABINET ON CONCRETE PAD EXISTING VERIZON II EXISTING UTILITY H-FRAME GAMMA C1 PROPOSED COMMSCOPE — FW-65B—R3 5G 1.9" X 11.81 310' 130 -0" (4) 7/8" COAX EQUIPMENT PLATFORRMM it (160 LONG) A&E PROJECT NUMBER EXISTING CHAIN LINKINYNYCO2239A FENCE (TYP) L I� ^1 DISH WIRELESS PROJECT INFORMATION RRH SECTOR POSITION MANUFACTURER — MODEL = N Y N Y C 0 2 2 3 9 A NUMBER TECHNOLOGY 1. CONTRACTOR TO REFER TO FINAL CONSTRUCTION RFDS FOR ALL RF 61405 MAIN ROAD, R0UTE 25 DETAILS. Al FUJITSU — TA08025-B605 N71 / i SOiUTHOLD, NY 11971 ALPHA 2. ANTENNA AND RRH MODELS MAY CHANGE DUE TO EQUIPMENT Al FUJITSU — TA08025-8604 N70/N66 AVAILABILITY. ALL EQUIPMENT CHANGES MUST BE APPROVED AND REMAIN IN COMPLIANCE WITH THE PROPOSED DESIGN AND SEE EQUIPMENT 131 FUJITSU — TA08025-8605 N71 / I STRUCTURAL ANALYSES. SHEET TITLE LAYOUT (SHEET A-3) BETA B1 FUJITSU — TA08025—B604 N70/N66 EQUIPMENT ELEVATION, ANTENNA C1 FUJITSU — TA08025—B605 N71 / I LOCATION QTY EXISTING OR MANUFACTURER — MODEL SIZE (HxWxD) WEIGHT LAYOUT AND SCHEDULE PROPOSED NUMBER GAMMA SHEET NUMBER C1 FUJITSU — TA08025-13604 N70/N66 PLATFORM 1 PROPOSED RAYCAP RDIDC-9181—PF-48 18.98704.39"x8.15" 21.82Lbs 20' 10' 0 20' 40' A=2 PROPOSED NORTH ELEVATION ANTENNA SCHEDULE NO SCALE 3 1"=20' DISH Wireless L.I..C. TEMPLATE VERSION 34 — 06/11/2021 - - 7'-°» NOTES ` EQUIPMENT PLATFORM/LEASE AREA U 1'-0" " 1'-11" 1'-2" 2'-10" 1. CONTRACTOR TO BURY PLATFORM FEET WITH A MINIMUM OF 2" OF FILL PER EXISTING SITE SURFACE 0 PROPOSED DISH Wireless LLC a ® - - _ 2. WEED BARRIER FABRIC TO BE ADDED AT DISCRETION OF DISH a � Wireless LLC L.L.C. CONSTRUCTION MANAGER AT TIME OF L.L.C. GENERATOR PLUG 1 CONSTRUCTION. ONE SHEET 8'x8' INSTALLED UNDER ALL FOUR ii �� I I I I PROPOSED DISH FEET OF THE PLATFORM 4 MIL BLACK PLASTIC PROPOSED DISH Wireless LLC 11 i Wireless LLC ( ) L.L.C. GPS UNIT o uc>l 0 II i II I ( L.L.C. GPS UNIT 3. EQUIPMENT CABINET OMITTED FOR CLARITY WER PROTECTIVE DISH Wireless LLC I I t^ft I �, LLC PROPOSED DISH Wireless LLC II I . PROPOSED CABINET iii ! II o 6 \ L.L.C. PROPOSED DISH Wireless LLC II i N EQUIPMENT CABINET •I N W 5701 SOUTH SANTA FE DRIVE L.L.C. H-FRAME I LITTLETON, CO 80120 'Its II II _ _____________ PROPOSED DISH Wireless LLC I I` I *0 RIGID METAL r---------------j L.L.C .SAFETY SWITCH. SPACE io I 1 I I I I o CONDU �r------------- RESERVED FOR ADDITIONAL = _ C ° DISCONNECT IF REQUIRED. g - - - - iA p I - ______= I 07% till Ap% PROPOSED DISH Wireless LLC ii II I L�L.0 �' 1��ER SOCKS -PROMO SH11Vireless LCC ii ii a M I L.L.C. TELCO FIBER ! \ ii li PROPOSED DISH "i PROPOSED DISH Wireless LLC ENCLOSURE I 'j ii ii iv W Wireless LLC it I L.L.C. 200AMP METER SOCKET •II \ ii ii i i I L.L.C. POWER NPROTECTIVE - w PROPOSED DISH Wireless LLC ii°ii _ � r i N CABINET L.L.C. FIBER NTD, IF REQUIRED ' I = _ I M TH .r r� o :t I �___°__ II I„I •I "I II -_-- PROPOSED DISH Wireless LLC �--g.. �� .; , Cl 1 PROPOSED DISH Wireless LLC a, ' I� Ik /Al Ip --- M •- - L.L.C. EQUIPMENT H-FRAME L.L.C. EQUIPMENT PLATFORM II �i a I II g I I 695 ROUTE 46 WEST, SUITE 300 12" 9" 6" 3" 0 1' 2' i `� I PROPOSED - FAIRFIELD, NJ 07004 DISH Wireless PLATFORM EQUIPMENT PLAN i I LLC L.L.C. i I i SAFETY SWITCH. iv I I INSTALL IF I III REQUIRED BY COMMSCOPE MTC4045LP PROPOSED 2'-o"X2'-o"X2" I I LOCM. � I COMPANY i I 5X7 PLATFORM PLANPAVERSTONE BLOCK (TYP. 1 PER FOOTPAD, 4 TOTAL) co - DIMENSIONS (HxWxD) 16»x84"x60" SIDE - 5 LENGTH BAR •I GRATING TOTAL WEIGHT 423 LBS i r a i n�» i u� : - . i y ��'F ° I I • Jv1 1i`i �i 7i I� t iN EQUIPMENT 0D O /1 IIoI 11011 1� tiY �S I iii � » PLATFORM II I PVC CONDUIT (TYP) y��y oL 6 MIN THICK LAYER FOOTPAD i li i ii ii ' i ° GC TO PROVIDE EXTENDED 1 I I I� EQUIPMENT ° 08008 0 0 0 0 o O 11 „ „ _ ;, PLATFORM OF 3/4" COMPACTED (TYP) o o PROPOSED DISH Wireless LLC THREAD FOR PLATFORM IF 1 „ ,� I. 1 . CRUSHED STONE o ,� L.L.C. EQUIPMENT PLATFORM REQUIRED HEIGHT EXCEEDS 17" ' II 1 FOOTPAD (TYP) ,o I► I i 1 li 1I u r •I GROUND 1 u I� a 1 .- !1 �� i i � ii i 1 BUSS rL D 0 , „ 1 �� BAR GRATING FINISHED O N L �-i GRADE NEW YORK L PROFESSIONAL IQ d' 1 u I !Iii 1 1 OP O0 ENGINEER- LICENSE NUMBER 095374-1 ! PROPOSED ii = CHANNEL , . » -----------=--------------I- -- ') 2 -0"X2 -0'X2 ii`ii i i COMPACTED SUBGRADE II II 1 PAVERSTONE BLOCK 4 MIL WEED BARRIER (TYP) . 1 PER SIDE - 7' LENGTH BAR EQUIPMENT PLATFORM FOOTPAD IT IS A VIOLATION OF LAW FOR ANY PERSON MP) UNLESS THEY ARE ACTING UNDER THE DIRECTION FOOTPAD, 4 TOTAL) GRATING FRONT ELEVATION PROPOSED DISH Wireless LLC OF A LICENSED PROFESSIONAL ENGINEER ii I i ii i i TO ALTER THIS DOCUMENT. 1 . ado w . . .. .�. L.L.C. GPS UNIT (BEYOND) I� •w w • • O • • • O • • w w• QUIPM"-A• Ell 4 , 1 1 WI N JF (n mN,I I`i 1 1;ra •I PLATFORM DRAWN BY: CHECKED BY: APPROVED BY: 6" MIN THICK LAYER OF 3/4" FOOTPAD COMPACTED CRUSHED STONE oc (TYP) O 0 MDC JAA JKM 6'-O" a- I RFDS REV #: 3 7$-OM 12 PRELIMINARY PROPOSED 2'-0"X2'-0"X2" PAVERSTONE BLOCK COMPACTED SUBGRADE PROPOSED DISH (TYP. 1 PER FOOTPAD 4 TOTAL) ,I Wireless LLC DOCUMENTS PLATFORM DETAIL NO SCALE 2 it L. NIID,FIFER II REQUIRED SUBMITTALS �I z a---m II°il REV DATE DESCRIPTION 0 14U 1 It: II , u`r--z c`rr—Z Z o O A 08-23h21 INRW. SUBmuI�ON COMMSCOPE MTC4045HFLD OR DISH Wireless LLC ;' H-FRAME �� �� �� L.L.C. APPROVED II 0 09-20-21 ISSUED FOR PERbIIT '" II 1 11-05-21 ISSUED FOR PERMIT PROPOSED DISH Wireless LLC _ _ _ 2 11-30-21 ISSUED FOR I +rr UNISTRIUT/SUPPORT RAILS QTY 5 60" -- - ----- DIPLEXER ON PROPOSED T --- WEIGHT 59.74 Ibs 50" PROPOSED DISH Wireless LLC H-FRAME (TYP OF 4 PER H-FRAME ON NEW CONCRETE SECTOR, 12 TOTAL) 7 PIPE CAP PIERS S E��SHEET (STACKED) � ® i PROPOSED DISH Wireless A&E PROJECT NUMBER LLC L.L.C. TELCO FIBER I 4 I °� ENCLOSURE o NYNYCO2239A WELDMENT PIPE w DISH 3 C3 ca RTC pTq WIRELESS PROJECT INFORMATION � g NYNYCO2239A 61405 SUPPORT RAIL m MAIN ROAD, ROUTE 25 o _:,r.�. e c 0 0 0 0 0 c PROPOSED DISH Wireless LLC SO UTH O LD, NY 11971 in ° U60 Ld6ff L.L.C. EQUIPMENT PLATFORM GALV. U-BOLTS PROPOSED DISH Wireless LLC PROPOSED DISH Wireless LLC RRH ON PROPOSED PVC CONDUIT (TYP) FINISHED OVP BOX ON PROPOSED H-FRAME (TYP OF 2 PER o L=J oo. GRADE SHEET TITLE o H-FRAME SECTOR, 6 TOTAL) (STACKED) EQUIPMENT PLATFORM A N D 4 MIL WEED BARRIER (TYP) H—FRAME DETAILS BASE PLATE EQUIPMENT PLATFORM FOOTPAD (TYP) SHEET NUMBER � FRONT BACK ELEVATION 12» 91f 6» 390 0 1' 2' A-3 H-FRAME DETAIL NO SCALE 3 H-FRAME RRH PLAN NO SCALE 4 H-FRA E EQUIPMENT ELEVATION 5 DISH Wireless L.L.C. TEMPLATE VERSION 34 - 06/11/2021 ENERSYS HEX CABINET RAYCAP PPC SQUARE D SAFETY SWITCHES �l 2000005996 \ RDIAC-2465—P-240—MTS D224NRB DIMENSIONS (HxWxD): 73"x30"x32" ENCLOSURE DIMENSIONS (HxWxD): 39"x22.855 x12.593 ENCLOSURE DIM (HxWxD) 29.25"09.00"x8.50I r I I h" WEIGHT: 376 LB I WEIGHT: 80 lbs ENCLOSURE TYPE NEMA 3R RAINPROOF OPERATING AC VOLTAGE 240/120 1 PHASE 3W+G I4� HEATER SOOW ELM I4L UL LISTED FILE E-2875 POWER SYSTEM –48V ALPHA/600A L TM L L C kd , 00 00 ® 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 0 O O O O O O O • 0 0 0 0 0 0 O 0 0 O O O ° INA TH ) 000 mow ow ANT 695 ROUTE 46 WEST, SUITE 300 FAIRFIELD, NJ 07004 CABINET DETAIL NO SCALE POWER PROTECTION CABINET (PPC) DNO SCALE 2 SAFETY SWITCH DETAIL NO SCALE 3 EATON METER SOCKET ZAYO 5RU CABINET _ CHARLES CFIT—PF202ODSH 1 UNRRS213BEUSE LEFT SWING DOOR ("LIT" SITES) r FIBER TELCO ENCLOSURE METER SOCKET TYPE RING DIMENSIONS (HxWxD) 36.115"x29"x12.9" I ( ENCLOSURE DIMS (HxWxD) 20"x20"x9" ENCLOSURE DIM (HxWxD) 16"x12"x6" 0 WEIGHT 85 LBS ENCLOSURE WEIGHT 20 The ok- :: . MAIN AMPERE RATING 200A MOUNTING WALL ELM POWER INPUT 20A, –48VDC WEIGHT 18 LBS PLAN COMPLIANCE TYPE 4 G FRONT ® gc=== ® ® eca ® r� r ® ® ® ® ® ® //j E R F 0 ' N YORI O NEW® ® � JIONAL • • • • • • 17-0 -0 -01 ENGINEER- LIC R:095374-1 �— O O e e e IT IS A VIOLATION OF LAW FOR ANY PERSON, • UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. • � � X • DRAWN BY: CHECKED BY: APPROVED BY: • ® ® ® e -v • 0 O MDC JAA JKM O ® ® ® a=a ® e e RFDS REV #: 3 0 0 0 . . ® d®� 0 0 PRELIMINARY DOCUMENTS METER SOCKET DETAIL NO SCALE 4 NETWORK INTERFACE UNIT DETAIL NO SCALE 5 FIBER TELCO ENCLOSURE DETAIL NO SCALE 6 SUBMITTALS REV DATE DESCRIPTION C O M M S C O P E WB—K1 10—B INCLUDED WB–T12-3 TRAPEZE KIT, A 05-23-21 FLEXIBLE RIGID PRODUCTS: 3 RUNGS 0 09-20-21 IISSM FOR POW PROPOSED INNER EMT WAVEGUIDE BRIDGE KIT 1 1121 ,M FORr ICE BRIDGE DUCTS CONDUIT DEWB–L812-3 SUPPORT BRACKEDIMENSIONS (HxL) 160"x10' 2 11-30►-21 ISS<IED FOR PER1WiT MF-130 DIRECT BURIAL PIPE FINISH SLOPE PROPOSED X" DW HYBRID CABLE I I WEIGHT/ VOLUME 325.0 LBS COLUMN, 13'-4" TO DRAIN (OP11ON "A'-) I I CONDUIT SUPPORT M I 1 BRACKET AND BANDING CABLE RUN (QTY) 12 PROPOSED X" DIA 11 ® 10'-0" O.C. A&E PROJECT NUMBER HYBRID CABLE I I (OPTION "81 �� SUPPORT BRACKET A–A A–A (WB-LB12-3) NYNYCO2239A 01 TRAPEZE KR DISH WIRELESS PROJECT INFORMATION (WB–T12-3) PRO " • 3" DIA SCH 40 PIPE m PROPOSED SCH40EPI E'S D �° N Y N Y C 0 2 2 3 9 A CABLE CLAMP SUPPORT BRACKET 8 0 3'-0" O.C. (WB-1.812-3) s GALVANIZEDM 18" DIA DRILLED 61405 MAIN ROAD, ROUTE 25 \-- °°° °°° TRAPEZE EZE KIT " PIER FOUNDATION SO�UTHOLD, NY 11971 EXISTING 82-3) PROPOSED 10-6" °°° °°° DIA. CONCRETE MONOPOLE PIER (TYP) ` 8 I Ll ° A-A SECTION ° °°° °°° SHEET TITLE 3.5" DIA GALV SCH EQUIPMENT DETAILS 40 PIPE (SPACED — 3.5" DIA GALV SCH JA 9'-0" MAX) 40 PIPE (SPACED (MF-130) 9'-0" MAX) (MF-130) CONCRETE PIER SHEET NUMBER PLAN FRONT sm A- 4 HYBRID CABLE RUN NO SCALE 7 ICE BRIDGE DETAIL NO SCALE $ TYPICAL ICE BRIDGE CONCRETE PIER DETAIL NO SCALE 9 DISH Wireless L.I..C. TEMPLATE VERSION 34 – 06/11/2021 PCTEL 1.75*0 GL—TMG—SPI-40NCB GPs MINIMUM OF 7576 OR 1.6004 DIMENSIONS (DIAxH) MM/INCH 81 x184mm 0 270' IN ANY DIRECTION 3.2"x7.25" WEIGHT W/ACCESSORIES 075 lbs GPS CONNECTOR N—FEMALE FREQUENCY RANGE 1590 t 30MHz ego ��ti eq, ¢; W ,. LLC o /ti s 5701 SOUTH SANTA FE DRIVE CUI2PSM6P4XXX CUI2PSM9P6XXX LITTLETON, CO 80120 GPS UNIT OBSTRUCTIONS MUST (4 AWG CONDUCTORS) (6 AWG CONDUCTORS) BE BELOW 10' 1.41"4I • o O J 0 0 4 0 0 0 ego'�� AFA O o div I NAN T CUI2PSM9P8XXX s (8 AWG CONDUCTORS) 695 ROUTE 46 WEST, SUITE 300 2 GPS DETAIL No SCALE � GPS MINIMUM SKY VIEW REQUIREMENTS No SCALE MINIMUM BEND RADIUSES CABLES UNLIMITED HYBRID CABLE NO SCALE 3 FAIRFIELD, NJ 07004 AS REQUIRED FOR _ WATERTIGHT ENDCAP INSTALLATION STANDARD UNISTRUT LINE DETAILS END CAPS (TYP.) / 1-5/8" P1000 UNISTRUT ATTACHED UNE TYPE COAX c r WITH STANDARD PIPE U ERE a N zz CLAMPS �P,) MANUFACTURER TBD NEW YORK L SSIONAL 8 RMODEL NUMBER COAX - 7/8 ENGINEER- LICENSE MBER:095374-1 W DIAMETER (O.D. IN.) 1.102 'j Z » (3.5» O.D.) IT IS A VIOLATION OF LAW FOR ANY PERSON, — 3 � �nSCH 40 WEIGHT (Lbs' PER FT.) 0.302 UNLESS A LICENSED ACTING PROFETHE SSIONAL ENG NIEECTION 4. SUPPORT PIPE QUANTITY 12 TO ALTER THIS DOCUMENT. z SLOPE CONC. APPROX. CABLE LENGTH 140 DRAWN BY: CHECKED BY: APPROVED BY: AWAY FROM $F POST 5 FlNISHED �� MDC JAA JKM GRADE z lix RFDS REV #: 3 74 u PRELIMINARY DOCUMENTS LINE DETAILS 5 NOT USED M r•,. ,� :: NO SCALE NO SCALE 6 SUBMITTALS • REV DATE DESCRIPTION 4t '4► (MIN) BIuIISSION A 08-,23-21 INffX SU 1 0 09-:20-21 ISSUED FOR PERMIT 1 11-105-21 ISSUED FOR PERMIT 2 11-30-21 ISSUED FOR PERMIT VOTES: 1. CONTRACTOR SHALL FIELD LOCATE THE H—FRAME AS SHOWN ON SITE PLAN. INSTALL THE A&E PROJECT NUMBER H—FRAME NEAR THE PERIMETER OF THE FENCED COMPOUND WITH THE METERS FACING THE FENCE. NYNYCO2239A 2. THE CONTRACTOR SHALL COORDINATE WITH THE LOCAL UTILITY COMPANY FOR THE CONDUIT RUN TO THE MAIN SERVICE CONNECTION OR TRANSFORMER. DISH WIRELESS PROJECT INFORMATION THE CONTRACTOR SHALL COORDINATE WITH THE LOCAL UTILITY COMPANY FOR THE GROUND ROD N Y N Y C 0 2 2 3 9 A REQUIREMENTS. IF REQUIRED, THE CONTRACTOR SHALL ORDER AND PAY FOR NECESSARY GROUND61405 MAIN ROAD, ROUTE 25 4. SUPPORT POSTS AND UNISTRUTS SHALL BE GALVANIZED. PIPE CLAMPS AND HARDWARE SHALL SOUTHOLD, NY 11971 BE GALVANIZED OR STAINLESS STEEL 5. ADJUSTMENTS TO THE H—FRAME DESIGN MAY BE REQUIRED DEPENDING ON THE EXACT METER PANEL INSTALLED. CONTRACTOR SHALL FIELD COORDINATE ADJUSTMENTS AND INFORM THE ENGINEER IF ANY UNUSUAL CONDITIONS ARE FOUND TO EXIST. SHEET TITLEEQUIPMENT DETAILS 6. REFER TO ELECTRICAL SHEETS FOR ADDITIONAL EQUIPMENT INFORMATION. SHEET NUMBER A=5 H—FRAME DETAIL 0 RRU LOCATION NO SCALE 4 NOT USED NO SCALE 7 NOT USED NO SCALE 8 DISH Wireless LLC. TEMPLATE VERSION 34 — 06/11/2021 FUJITSU TRIPLE BAND FUJITSU DUAL BAND EEI TRIAD—FPS MOUNT TA08025 13605 TA08025-13604 DIMENSIONS (HxWxD) 2"x5.72"x.25" 0 O O DIMENSIONS (HxWxD) 14.9"x15.7"x9" DIMENSIONS (HxWxD) 14.9"x15.7"x7.8" lt:n5r WEIGHT: 5.5 LBS QTY: 6 w �� WEIGHT 74.95 lbs ° WEIGHT 63.9 The e FPS PLAN 4.3-10 RF 4.3-10 RF SPECIFICATIONS: ROUND OR POLYGON POLES 3" FPS FRONT CONNECTOR TYPE CONNECTOR CONNECTOR TYPE CONNECTOR TO 7" DIA., 1/4" BRACKET ASSEMBLY POWER SUPPLY DC -58N-36V PLAN POWER SUPPLY DC -58N-36V PLAN LLC EEI TRIAD—AB MOUNT 5701LITSOUTH ANTE TLETONS CO 80120DRIVE o e ° e DIMENSIONS (HxWxD) 2700"x.25" AB PLAN e e WEIGHT: 2 LBS QTY: 6 SPECIFICATIONS: ANTENNA BRACKET, 1/4* HRPO A GUSSET ASSEMBLY AB FRONT e e *1 OFM L3 M LJ EEI e e TRIAD-AB O BOLT, HEX NUT, El 11 FLAT WASHER & LOCK WASHER IM �1S �1QE EBQdI �K �1QE EBQdI O O EEI TRIAD-FPS POLE reF r.� r"'p Fp �7'' Imo`.C. THREADED �/AB FRONT ROD (TYP) FPS/AB PIAN 695 ROUTE 46 WEST, SUITE 300 FAIRFIELD, NJ 07004 RRH DETAIL No SCALE RRH DETAIL NO SCALE 2 MAST MOUNT DETAIL No SCALE 3 COMMSCOPE M04 MOUNTING BRACKET RAYCAP RDIDC-9181 —PF-48 FVV-65B—R3 ANTENNA HPA-33R—BUU—H4—K DC SURGE PROTECTION (OVP) DIME14SIONS (HxWxD) 71.9"x11.8"x7.1" WIDTH 5" DIMENSIONS (HxWxD) 18.98"x14.39"x8.15" TOTAL WEIGHT 43.8 LB DEPTH 2" WEIGHT 21.82 LBS 4/C, y� RF PORT:, CONNECTOR TYPE 6 x 4.3-10 FEMALE HEIGHT 8" PLAN 09� MOUNTING z r TOTAL WEIGHT 1.5 lbs BRACKET 'w - e e • HOUSING MATERIAL ASA/ABS/ALUMINUM ANTENNA Aj E R 3, ON RADOME COLOR LIGHT GRAY 0 NEW YOR ROFESSIONAL CONNECTOR 1X8-PIN DAISY CHAIN MOUNTING ENGINEER- LICENSE NUMBER:095374-I BRACKET IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: MDC JAA JKM MOUNTING L PIPE IFRFDS REV #: 3 Ir ill OR DISH Wireless LLC . . EQI 11 VA1APPROVED PRELIMINARY FRONTWE 216m FRONT DOCUMENTS ANTENNA DETAIL No SCALE 4 ANTENNA MOUNTING DETAIL NO SCALE 5 SURGE SUPPRESSION DETAIL (OVP) No SCALE 6 SUBMITTALS REV DATE DESCRIPTION A 05-23-21 INMAL SUBMISSION COMMSCOPE O 09-20-21 ISSUED FW PMIr CDX623T—DS—B DIPLEXER 1 1121 ISSUED FOR Poria,. DIMENSIONS (HxWKD) 8.8"x4.9"x4.5" 2 11-30-21 ISSUED FM PEW WEIGHT 10.14 Ibs CONNECTOR TYPE 7-16 DIN FEMALE A&E PROJECT NUMBER NYNYCO2239A Oo0 PLAN DISH WIRELESS PROJECT INFORMATION NYNYCO2239A .o 61405 MAIN ROAD, ROUTE 25 SOUTHOLD, NY 11971 0 SHEET TITLE BACKFBQdI EQUIPMENT DETAILS �1QE SHEET NUMBER A=6 DIPLEXER DETAIL NO SCALE 7 NOT IN USE No SCALE $ NOT IN USE No SCALE 9 DISH Wireless L.L.C. TEMPLATE VERSION 34 - 06/11/2021 NOTES DC POWER WIRING SHALL BE COLOR CODED AT EACH END FOR IDENTIFYING +24V AND —48V CONDUCTORS. 0 RED MARKINGS SHALL IDENTIFY +24V AND BLUE MARKINGS SHALL IDENTIFY —48V. 1. CONTRACTOR SHALL FIELD VERIFY ALL PROPOSED UNDERGROUND UTILITY CONDUIT ROUTE. 2. ANTENNAS AND MOUNTS OMITTED FOR CLARITY. 1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING A BID. ANY QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTOR'S FUNCTIONS, THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. L� ' LLC^v.1tj m' ' 2. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL ELECTRICAL CODES AND ALL STATE AND LOCAL CODES, LAWS, AND ORDINANCES. PROVIDE ALL COMPONENTS AND WIRING SIZES AS 5701 SOUTH SANTA FE DRIVE LITTL REQUIRED TO MEET NEC STANDARDS. TON, CO 80120 3. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE COORDINATED WITH FIELD CONDITIONS PRIOR TO CONSTRUCTION. 4. CONDUIT ROUGH—IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS. VERIFY WITH THE MECHANICAL EQUIPMENT CONTRACTOR AND COMPLY AS REQUIRED. A EXISTING WOODED AREA 5. CONTRACTOR SHALL PROVIDE ALL BREAKERS, CONDUITS AND CIRCUITS AS REQUIRED FOR A COMPLETE SYSTEM. 6. CONTRACTOR SHALL PROVIDE PULL BOXES AND JUNCTION BOXES AS REQUIRED BY THE NEC ARTICLE 314. 7. CONTRACTOR SHALL PROVIDE ALL STRAIN RELIEF AND CABLE SUPPORTS FOR ALL CABLE ASSEMBLIES. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. TH S. ALL DISCONNECTS AND CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED PHENOLIC NAMEPLATES INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM. 695 ROUTE 46 WEST, SUITE 300 9. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC 250. FAIRFIELD, NJ 07004 THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL DISCONNECT SWITCHES, AND EQUIPMENT CABINETS. 10. ALL NEW MATERIAL SHALL HAVE A U.L LABEL. 11. PANEL SCHEDULE LOADING AND CIRCUIT ARRANGEMENTS REFLECT POST—CONSTRUCTION EQUIPMENT. PROPOSED UNDERGROUND POWER 12. CONTRACTOR SHALL BE RESPONSIBLE FOR AS—BUILT PANEL SCHEDULE AND SITE DRAWINGS. CONDUIT (LENGTH: 240'-0"t) 13. ALL TRENCHES IN COMPOUND TO BE HAND DUG PROPOSED UTILITY METER ® PLATFORM s' SPAY " `'`t, '\o H—FRAME . JE d. 3 N NEW Y'0 SOF SSIONAL DENGINEER- L F1BER:095374-1 • � x x x � p11�- �'-om"'P- ��- - -� x F-P F ( I o IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION I I I \ I I OF A LICENSED PROFESSIONAL ENGINEER, x TO ALTER THIS DOCUMENT. I DRAWN BY: CHECKED BY: APPROVED BY: x / PROPOSED UNDERGROUND FIBER MDC JAA JKM x \ \ CONDUIT (LENGTH: 75'-0"t) Il REDS REV #: 3 x � J x ......... ...... I x PRELIMINARY x L - - - - J x DOCUMENTS �x x x x x x x x x x x x xJ SUBMITTALS REV DATE DESCRIPTION A 08-23-21 INM& SUBMISSION 0 09-20-21 ISSUED FOR PERM 1 11-05-21 ISSUED FOR PWff 2 11-30-21 ISSM FOR PERMfT EXISTING PAVED PARKING AREA EXISTING BUILDING A&E PROJECT NUMBER NYNYCO2239A DISH WIRELESS PROJECT INFORMATION NYNYCO2239A 61405 MAIN ROAD, ROUTE 25 SOUTHOLD, NY 11971 SHEET TITLE ELECTRICAL/FIBER ROUTE PLAN AND NOTES SHEET NUMBER 0' 20, Eml UTILITY ROUTE PLAN 12 $ 4 mmould 1 ELECTRICAL NOTES NO SCALE 2 34.32"=V-0" DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 DC POWER WIRING SHALL BE COLOR CODED AT EACH END FOR IDENTIFYING +24V AND -48V CONDUCTORS. RED MARKINGS SHALL IDENTIFY +24V AND BLUE MARKINGS SHALL IDENTIFY -48V. X. 1. CONTRAC'T'OR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING A BID. ANY QUESTIONS ARISING 00 DURING THE BID PERIOD IN REGARDS TO THE CONTRACTOR'S FUNCTIONS, THE SCOPE OF WORK, OR ANY DISH Wireless LLC DISH Wireless LLC L.L.C. OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT L.L.C. PROVIDES 0 0 FIBER DISTRIBUTION PANEL. MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. 12AWG WIRE ( ' PROPOSED DISH Wireless LLC NOTE: FIBER PROVIDER W--A LLC 2. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL ELECTRICAL CODES AND ALL TAIL) L.L.C. PROPOSED FIBER WILL NEED TO PROVIDE AN T"" STATE RNID LOCAL. CODES, LAWS, AND ORDINANCES. PROVIDE ALL COMPONENTS AND WIRING SIZES AS CO FIBER ENCLOSURE PROPOSED DISH Wireless LLC NID, IF REQUIRED ADDITIONAL 5FT UNISTRUT, REQUIRED TO MEET NEC STANDARDS. � L.L.C. UNI9�Rt�T-- 2 U-BOLTS WITH 4 NUTS, 57011 SOUTH SANTA FE DRIVE IN THE EVENT THE BRACKET SPACING DOESN'T LITTLETON, CO 80120 3. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE PROPOSED DISH Wireless UNE UP WITH CURRENT COORDINATED WITH FIELD CONDITIONS PRIOR TO CONSTRUCTION. LLC L.L.C. UNI SPACING BELOW PROPOSED FIBER PROVIDER 1-1/4" FLEX CONDUITS IN IN OUT iocc 4. CONDUIT ROUGH-IN SHALL BE COORDINATED WITH THE MECHANICALDISH Wireless LLC L.L.C.EQUIPMENT TO AVOID LOCATION CONFLICTS. VERIFY WITH THE MECHANICAL EQUIPMENT CONTRACTOR AND COMPLY AS REQUIRED. FIBER JUMPER TO CABINET FIBER PROVIDER TO TERMINATE ' •A WILL NEED TO BE POWER TO FIBER PROVIDER NID FIBER PROVIDER TO PUNCH TOP OF 5. CONTRACTOR SHALL PROVIDE ALL BREAKERS, CONDUITS AND CIRCUITS AS REQUIRED FOR A COMPLETE SYSTEM. TERMINATED BY FIBER TELCO BOX OF NID ENCLOSURE AND PROPOSED DISH PROVIDER ON OTHER SIDE OF PROPOSED DISH Wireless LLC INSTALL 1-1/4* LIQUID TIGHT Wireless LLC L.L.C. BULKHEAD/LC TO LC L.L.C. 12 AWG WIRE (6CONNECTORS, UL LISTED, NYLON 6. CONTRACTOR SHALL PROVIDE PULL BOXES AND JUNCTION BOXES AS REQUIRED BY THE NEC ARTICLE 314. 10 AMP DISTRIBUTION CONNECTOR WHERE CIRCUIT MATERIAL, WITH 0-RING GASKET BREAKER � � IS TERMINATED. FIBER PROVIDER TO INSTALL 7. CONTRACTOR SHALL PROVIDE ALL STRAIN RELIEF AND CABLE SUPPORTS FOR ALL CABLE ASSEMBLIES. INSTALLA11ON SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. IN IN PROPOSED DISH Wireless LLC FDP/TELCO BOX do N D CONDUITS BETWEEN AH �TH PROPOSED FIBER PROVIDER L.L.C. ,-.,I� 9 rtl y ,6$ '* 8. ALL DISCONNECTS AND CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED PHENOLIC NAMEPLATES PROPOSED DISH Wireless LLC 0 0 FIBER LATERAL FROM RIGHT 10 AMP DISTRIBUTION BREAKER PROPOSED DISH Wireless LLC `" INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM. L.L.C. OF WAY TO STREET, PROPOSED DISH Wireless LLC L.L.C. TERMINATED TO FDP %IsH"�'irAff LLC 695 ROUTE 46 WEST, SUITE 300 OwE�R�SH Wireless LLC L.L.C. 9. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC 250. L.L.C. PROPOSED DISH Wireless LLC 12 AWG WIRE L.L.C. FAIRFIELD, NJ 07004 THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL 1-1,/2" POWER FROM CABINET L.L.C. IN IN 1-1/2* FIBER TO CABINET DISCONNECT SWITCHES, AND EQUIPMENT CABINETS. DIS„ Wireless LLC L.L.C. 1-1��" FlBE1� TO CABINET INSTALLS 1-1/2" CONDUITS PRO SED DI H Wireless LLC PROPOSED DISH Wireless LLC 0 PROPOSED DISH Wireless LLC FOR POWER AND FIBER L.L.C. 2" CONDUIT FROM L.L.C. L.L.C. 2" CONDUIT FROM 10. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL. CABINET COMMERCIAL FIBER VAULT 1-1/2" POWER FROM CABINET COMMERCIAL FIBER VAULT 11. PANEL SCHEDULE LOADING AND CIRCUIT ARRANGEMENTS REFLECT POST-CONSTRUCTION EQUIPMENT. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR AS-BUILT PANEL SCHEDULE AND SITE DRAWINGS. 4 ELECTRICAL NOTES No SCALE DARK TELCO BOX — INTERIOR WIRING LAYOUT No SCALE2 LIT TELCO BOX — INTERIOR WIRING LAYOUT (OPTIONAL No SCALE I' ER 5 N NEW YO Z9;ESSIONAL EXISTING 5 SINGLE ENGINEER- LI R:095374-I _ MOUNTED METER SOCKETS ON EXISTING H-FRAME IT IS A VIOLATION OF LAW FOR ANY PERSON, SPACES WITH 1 EMPTY METER PROPOSED DISH Wireless UN OFLICENSED IA APROFESSIONAL S CTING IDER T ENGHE INEER,, LLC 200A POWER METER TO ALTER THIS DOCUMENT. WITH DISCONNECT PROPOSED DISH Wireless LLC LOAD CENTER AT 200A PPC DRAWN BY: CHECKED BY: APPROVED BY: CABINET POWER SECTION MDC JAA JKM M M M • M M 200/3 RFDS REV #: 3 2 NU AL PRELIMINARY PROPOSED DISH PR p�H� DOCUMENTS Wireless LLC 200A, Wireless 120/208V, 10 3W LLC SUBMITTALS AC CABINET TELCO CABINET EXISTING REV DATE DESCRIPTION • MESA CABINET A 06-23-21 INMAL SUBMISSION SEE TRENCHING NOTE 1 2" RGS 0 09-20-21 ISS= Fat PEWIT - BACKFILL 1 11-05-21 MUM MR POW TRENCHING NOTES WORK SP PER SITE 2 11-30-21 W= Fat PEWff 1. CONTRACTOR SHALL RESTORE THE (SEE GENERAL NOTES) In TRENCH TO ITS ORIGINAL SLOPE TO SUIT SOIL CONDITIONS BY EITHER SEEDING CONDITION IN ACCORDANCE OR SODDING GRASS AREAS, OR WITH LOCAL REGULATIONSPWR PWR PWR PWR PWR PW — PWR REPLACINI; ASPHALT OR CONCRETE SEE TRENCHING NOTE 2 ra PWR PWR PyWR PWR PWR A&E PROJECT NUMBER AREAS TO ITS ORIGINAL CROSS6" WIDE WARNING TAPE SECTION. FBR FBR FBR FBR FBR NYNYCO2239A 2. TRENCHING ' �\ 3 SAFETY, INCLUDING, o �� / o= BUT NOT,LIMITED TO SOIL 1 //\ /\�/ m= PVC SCH. 40 CONDUIT FOR FIBER CADWELD DISH WIRELESS PROJECT INFORMATION CLASSIFICATION, SLOPING, AND It 3 (CM TO CONFIRM) NOTE. N Y N Y C 0 2 2 3 9 A SHORING SHALL BE GOVERNED = / / t 0:20 RISER DIAGRAM IS FOR REFERENCE 614 0 5 MAIN ROAD,A D ROUTE 2 5 BY THE CURRENT OSHA a o , TRENCHING AND EXCAVATION � v = �' : � \ . N ONLY. WIRE SIZES AND FINAL WIRING 6o o �/ ;• �:M: :M // o PVC scH. 4o CONDUIT CCONFIGURATION OMPLETION OF TUTILITYPCONSUET. R SOUTHOLD, NY 11971 SAFETY STANDARDS. z j . : 3. ALL CONDUITS SHALL BE / , :.� GROUND ROD INSTALLED IN COMPLIANCE WITH N THE CURRENT NATIONAL SHEET TITLE /� Ti. / ELECTRIC CODE (NEC) OR AS UTILITY WARNING TAPE PVC SCH. 40 CONDUIT ELECTRICAL DETAILS REQUIRED BY THE LOCAL SAND BEDDING PER SITE AND RISER DIAGRAM JURISDICTION, WHICHEVER IS WORK SPECIFICATIONS THE MOST STRINGENT. SHEET NUMBER E=2 TYPICAL UNDERGROUND TRENCH DETAIL No SCALE 4 ELECTRICAL RISER DIAGRAM No SCALE 5 DISH Wireless L.L.C. TEMPLATE VERSION 34 - 06/11/2021 NOTES THE ENGINEER OF RECORD HAS PERFORMED ALL REQUIRED SHORT CIRCUIT , PROPOSED POWER PROTECTIVE CABINET ENERSYS NETWORK CABINET CALCULATIONS AND THE AIC RATINGS FOR EACH DEVICE IS ADEQUATE TO PROTECT THE UTILITY SERVICE ENTRANCE 120/24OV, 1 PH, SERVICE RATED, EQUIPMENT AND THE ELECTRICAL SYSTEM. 240 VAC 1 PH OVERALL UL LISTED POWER CENTER, 120/240 N3R, 65K/10K AIC THE ENGINEER OF RECORD HAS PERFORMED ALL REQUIRED VOLTAGE DROP CALCULATIONS AND ALL BRANCH CIRCUIT AND FEEDERS COMPLY WITH THE NEC BACKUPMAIN BREAKER WITH (LISTED ON T-1) ARTICLE 210.19(A)(1) FPN NO. 4. GENERATOR 200A 200A INTERLOCKED GENERATOR CAMLOCK FEED, 200A 65K AIC (3) PROPOSED CONDUIT SIZING: AT 4OX FILL PER NEC CHAPTER 9, TABLE 4, ARTICLE 358. GEN PLUG 0.75" EMT CONDUITS 0.5"" CONDUIT - 0.122 SQ. IN AREA sr N 0.75 CONDUIT - 0.213 SQ. IN AREA TM LLC SURGE SUPPRESSIO 2.0" CONDUIT - 1.316 SQ. IN AREA DEVICE 100KA SAD/MOV 3.0" CONDUIT - 2.907 SQ. IN AREA 5701 SOUTH SANTA FE DRIVE GFCI15A 01 02 , PROPOSED 2 8, 1 8 CU GND. CABINET CONVENIENCE OUTLET CONDUCTORS (1 CONDUIT): USING THWN-2, CU. LITTLETON, CO 80120 03 04 FOR RECTIFIERS 1 do 2 20A j10 - 0.0211 SQ. IN X 2 - 0.0422 SQ. IN 05 06 PROPOSED 2 8, 8 CU GN X10 - 0.0211 SQ. IN X 1 0.0211 SQ. IN <GROUND SPACE 07 08 40A FOR RECTIFIERS 3 do 4 TOTAL - 0.0633 SQ. IN SPACE 09 ZA 10 SHARED GROUND WIRE • PROPOSED 2 8 8 CU G 0.5" EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (3) WIRES, SPACE 11 12 OA FOR RECTIFIER 5 INCLUDING GROUND WIRE, AS INDICATED ABOVE. SPACE (3) 3/0 WITH #6 GROUND 13 =16 RECTIFIER CONDUCTORS (3 CONDUITS): USING UL1015, CU. IN 3" SCH 40 CONDUIT SPACE 15 #8 - 0.0552 SQ. IN X 2 - 0.1103 SQ. IN SPACE 17 18 SPACE 8 - 0.0131 SQ. IN X 1 - 0.0131 SQ. IN <BARE GROUND A I TH SPACE SPACE TOTAL - 0.1234 SQ. IN b- 19 20 (1) PROPOSED N,h. . :. Ik> tl ! . SPACE 21 22 SPACE 0.5" EMT CONDUIT 0.75" EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (3) WIRES, INCLUDING GROUND WIRE, AS INDICATED ABOVE. 695 ROUTE 46 WEST, SUITE 300 SPACE SPACE TO UTILITY COMPANY 23 24 FAIRFIELD, NJ 07004 SPACE SPACE PPC FEED CONDUCTORS (1 CONDUIT): USING THWN, CU. PROPOSED 2 #10, 1 #10 CU GND. FOR CONVENIENCE OUTLET 3/0 - 0.2679 SQ. IN X 3 - 0.8037 SQ. IN #6 - 0.0507 SQ. IN X 1 - 0.0507 SQ. IN <GROUND TOTAL - 0.8544 SQ. IN CONTRACTOR TO REFER TO BRANCH CIRCUIT WIRING SUPPLYING RECTIFIERS ARE TO BE RATED U11.1015, 105C, 600V, AND PVC INSULATED, IN THE SIZES SHOWN 3.0" SCH 40 PVC CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (4) RES, FINAL UTILITY DESIGN DETAILS IN THE ONE-UNE DIAGRAM. CONTRACTOR MAY SUBSTITUTE UL1015 WIRE FOR THWN-2 FOR CONVENIENCE OUTLET BRANCH CIRCUIT. INCLUDING GROUND WIRE, AS INDICATED ABOVE. WI BREAKERS REQUIRED: (2) 40A, 2P BREAKER - SQUARED P/N:00240 (1) 20A, 2P BREAKER - SQUARE D P/N:00220 '0 ",c. (1) 20A, IP BREAKER - SQUARE D P/N:00120 C r �l r ON NEW YO FM FESSIONAL ENGINEER- L MBER:095374-1 PPC ONE-LINE DIAGRAM No SCALE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. FAULT CURRENT VALUES BASED ON DRAWN BY: CHECKED BY: APPROVED BY: POINT-TO-POINT METHOD OF CALCULATION MDC JA J KM F1 (SINGLE PHASE) F3 (SINGLE PHASE) RFDS REV #: 3 LOCATION: TRANSFORMER LOCATION: DISCONNECT TRANSFORMER SIZE = 100.0 kVA TYPE OF CONDUIT: PVC PRELIMINARY SECONDARY VOLTAGE (L-L) 240 V CONDUCTOR SIZE AND TYPE: 3/0 COPPER SECONDARY VOLTAGE (L-N) SETS OF CONDUCTORS = 1 DOCUMENTS = 120 V LENGTH OF CONDUCTORS = 10 FEET PROPOSED ENERSYS PANEL SCHEDULE ISC = 40,000 JA "C" VALUE = 13923 SUBMITTALS VOLT AMPS VOLT AMPS f(L-L) = 0.0821 REV DATE DESCRIPTION LOAD SERVED (WATTS) TRIP � PHASE � TRIP (WATTS) LOAD SERVED M(L-L) = 0.9241 A 08-23-.21 INMAL SUBMISSION Ll L2 Ll L2 PPC GFCI OUTLET 840 180 15A 1 A 2 40A 3ERSYS ALPHA CORD f(L-N) = 0.1065 0 09-20-21ERMIT 21 ISSUED FOR P ENERSYS GFCI OUTLET 180 20A 3 B 4 3840 RECTIFIERS 1 do 2 ISSUED= 0.9038 1 11-05-21 ISSFOR PERMIT' 840 -SPACE- 5 A 6 3ERSYS ALPHA CORDEX -SPACE- 7 B 8 40A 3840 RECTIFIER 3 & 4 F2 (SINGLE PHASE) ISC (L-L) = 12,679 A 2 11-30-21 ISSUED FOR PERMIT -SPACE- 9 A 10 1920 ERSYS ALPHA CORD ISC (L-N) = 8,038 A -SPACE- 11 B 12 20A 1920 RECTIFIER 5 LOCATION: METER -SPACE- 13 A 14 -SPACE- TYPE OF CONDUIT: PVC -SPACE- 15 B 16 -SPACE- CONDUCTOR SIZE AND TYPE: 3/0 COPPER -SPACE- 17 A 18 -SPACE- -SPACE- 19 B 20 -SPACE- SETS OF CONDUCTORS = 1 A&E PROJECT NUMBER -SPACE- 21 A 22 -SPACE- LENGTH OF CONDUCTORS = 80 FEET -SPACE- 23 B 24 -SPACE- "C" VALUE = 13923 F4 (SINGLE PHASE) NYNYCO2239A VOLTAGE NIPS I 180 180 9500 9500 f(L-L) = 1.9153 DISH WIRELESS PROJECT INFORMATION 200A MCB 1 24 SPACE, 120/240V L1 L2 LOCATION: 200A PPC Ma RATING: 65,000AIC 9680 9680 VOLTAGE AMPS M(L-L) = 0.3430 TYPE OF CONDUIT: PVC NYNYCO2239A 81 81 AMPS f(L-N) = 5.7459 81 MAX AMPS CONDUCTOR SIZE AND TYPE: 3/0 COPPER 102 1 MAX 125X M(L-N) = 0.1482 SETS OF CONDUCTORS = 1 61405 MAIN ROAD, ROUTE 25 ISC (L-L) = 13,721 A LENGTH OF CONDUCTORS = 30 FEET SOUTHOLD, NY 11971 ISC (L-N) = 8,894 A "C" VALUE = 13923 f(L-L) = 0.2277 M(L-L) = 0.8146 SHEET TITLE f(L-N) = 0.2887 ELECTRICAL ONE-LINE, FAULT M(L-N) = 0.7760 CALCS & PANEL SCHEDULE ISC (L-L) = 10,328 A ISC (L-N) = 6,238 JA SHEET NUMBER -3 PANEL SCHEDULE No SCALE 2 FAULT CALCULATIONS No SCALE 3 DISH Wireless LLC. TEMPLATE VERSION 34 - 06/11/2021 v EXOTHERMIC CONNECTION zITEST SEGROUND ROD CTION SLEEVE WITH �1 PROPOSED BUSS BAR � MECHANICAL CONNECTION TEST WELL INSULATORS ------ #6 AWG STRANDED do INSULATED T® I ® GROUND BUS BAR PROPOSED 4"02"x1/4" TINNED — — #2 AWG SOLID COPPER TINNED COPPER GROUND BUSSBAR O GROUND ROD A BUSS BAR INSULATOR Ulu E30ND PROPOSED EQUIPMENT ft, LLC PLATFORM TO PROPOSED GROUNDING ELECTRODE --- GROUNDING LE G E N D 5701 SOUTH SANTA FE DRIVE ''MIEM 4) LITTLETON, CO 80120 3 I ' 13OND H-FRAME POST TO ® EXISTING TOWER GROUND UNI-STRUT (TYP,) , RING (FEILD VERIFY) 1. GROUNDING IS SHOWN DIAGRAMMATICALLY ONLY. BOND ICE BRIDGE -SUPPORT POSTS TO 2. CONTRACTOR SHALL GROUND ALL EQUIPMENT AS A COMPLETE SYSTEM. GROUNDING SHALL BE IN II I I GROUND RING BOND(s) - - - COMPLIANCE WITH NEC SECTION 250 AND DISH Wireless LLC L.L.C. GROUNDING AND BONDING e (TYP ALL POSTS) -' EXISTING GUYED REQUIREMENTS AND MANUFACTURER'S SPECIFICATIONS. ( TOWER �. 1F2 AWG BURIED GROUND I \ 3. ALL GROUND CONDUCTORS SHALL BE COPPER; NO ALUMINUM CONDUCTORS SHALL BE USED. RING 30" BELOW GRADE AZINA TH jF2 TINNED SOLID IN 1/2 I I ! ° ° ,� 1 r,-F ... MIN. LIQUID TIGHT CONDUIT ° GROUNDING KEY NOTES �w ' I , � w p �Q.. I FROM 24" BELOW GRADE 'TO WITHIN 3" TO 6" OF I ° ° � d . EXTERIOR GROUND RING: #2 AWG SOLID COPPER, BURIED AT A DEPTH OF AT LEAST 30 INCHES BELOW 695 ROUTE 46 WEST, SUITE 300 CAD-WELD TERMINATION O GRADE, OR 6 INCHES BELOW THE FROST UNE AND APPROXIMATELY 24 INCHES FROM THE EXTERIOR WALL FAIRFIELD, NJ 07004 POINT. EXPOSED END OF :---- ° - ------ o OR FOOTING. 'THE LIQUID TIGHT CONDUIT ( -'� p ° ° ' TOWER GROUND RING. THE GROUND RING SYSTEM SHALL BE INSTALLED AROUND AN ANTENNA TOWER'S LEGS, INUIT BE SEALED WITH ��\�r----------- �-® ° SILICONE CAULK. (TYP) AND/OR GUY ANCHORS. WHERE SEPARATE SYSTEMS HAVE BEEN PROVIDED FOR THE TOWER AND THE BUILDING, AT LEAST TWO BONDS SHALL BE MADE BETWEEN THE TOWER RING GROUND SYSTEM AND THE BUILDING RING GROUND SYSTEM USING MINIMUM f2 AWG SOLID COPPER CONDUCTORS. INTERIOR GROUND RING: #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR EXTENDED AROUND THE ® PERIMETER OF THE EQUIPMENT AREA. ALL NON-TELECOMMUNICATIONS RELATED METALLIC OBJECTS FOUND WITHIN A SITE SHALL BE GROUNDED TO THE INTERIOR GROUND RING WITH #6 AWG STRANDED GREEN INSULATED CONDUCTOR. BOND EQUIPMENT AS REQUIRED BY MANUFACTURER BOND TO INTERIOR GROUND RING: #2 AWG SOLID TINNED COPPER WIRE PRIMARY BONDS SHALL BE ��P �,i �.• ��t.., ' O PROVIDED AT LEAST AT FOUR POINTS ON THE INTERIOR GROUND RING, LOCATED AT THE CORNERS OF THE Q� t PROPOSED EQUIPMENT GROUND RING TO D BUILDING. ! F EXISTING TOWER GROUND RING (TOTAL 2) GROUND RQD: UL LISTED COPPER CLAD STEEL MINIMUM 1/2" DIAMETER BY EIGHT FEET LONG. GROUND ORODS SHALL BE INSTALLED WITH INSPECTION SLEEVES. GROUND RODS SHALL BE DRIVEN TO THE DEPTH OF ER GROUND RING CONDUCTOR. NEW YO SIONAL TYPICAL E O U I P M E NT GROUNDING PLAN NO SCALE CELL REFERENCE GROUND BAR: POINT OF GROUND REFERENCE FOR ALL COMMUNICATIONS EQUIPMENT ENGINEER- L ErQ `095374-1 OF FRAMES. ALL BONDS ARE MADE WITH #2 AWG UNLESS NOTED OTHERWISE STRANDED GREEN INSULATED COPPER CONDUCTORS. BOND TO GROUND RING WITH (2) #2 SOLID TINNED COPPER CONDUCTORS. IT IS A \VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION HATCH PLATE GROUND BAR: BOND TO THE INTERIOR GROUND RING WITH TWO #2 AWG STRANDED GREEN OF A LIiCENSED PROFESSIONAL ENGINEER, OINSULATED COPPER CONDUCTORS. WHEN A HATCH—PLATE AND A CELL REFERENCE GROUND BAR ARE BOTH TO ALTER THIS DOCUMENT. G PRESENT, THE CRGB MUST BE CONNECTED TO THE HATCH-PLATE AND TO THE INTERIOR GROUND RING USING (2) TWO #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTORS EACH. DRAWN BY: CHECKED BY: APPROVED BY: PROPOSED AD (TYP) I I EXTERIOR .ABLE ENTRY PORT GROUND BARS: LOCATED AT THE ENTRANCE TO THE CELL SITE BUILDING. BOND MDC JAA JKM e TO GROUND RING WITH A #2 AWG SOLID TINNED COPPER CONDUCTORS WITH AN EXOTHERMIC WELD AND I I 0 INSPECTION SLEEVE. RFDS REV #: 3 EXISTING MAST PROPOSEDI ANTENNA ) I I O TELCO GROUND BAR: BOND TO BOTH CELL REFERENCE GROUND BAR OR EXTERIOR GROUND RING. ROUND MEMBER FRAME BONDING: THE BONDING POINT FOR TELECOM EQUIPMENT FRAMES SHALL BE THE GROUND BUS THAT PRELIMINARY O IS NOT ISOLATED FROM THE EQUIPMENTS METAL FRAMEWORK. ADAPTER PROPOSED DOCUMENTS STEALTH CANISTER I I INTERIOR UNIT BONDS: METAL FRAMES, CABINETS AND INDIVIDUAL METALLIC UNITS LOCATED WITH THE AREA OOF THE INTERIOR GROUND RING REQUIRE A #6 AWG STRANDED GREEN INSULATED COPPER BOND TO THE SUBMITTALS 3/8" HEX ORllllll/llllllllllllllBllll/lllllllllll I I INTERIOR GROUND RING. REV DATE DESCRIPTION EXISTING MAST FILUSTER BOLT I I FENCE AND GATE GROUNDING: METAL FENCES WITHIN 7 FEET OF THE EXTERIOR GROUND RING OR OBJECTS BONDED TO THE EXTERIOR GROUND RING SHALL BE BONDED TO THE GROUND RING WITH A f2 AWG SOLID A 08-23-21 LOCK WASHER O TINNED COPPER CONDUCTOR AT AN INTERVAL NOT EXCEEDING 25 FEET. BONDS SHALL BE MADE AT EACH 0 09-20-21 ISS= FOR POW 6"x2" GROUNDFLAT WASHER I 1 I GATE POST AND ACROSS GATE OPENINGS. t 11-05-21 ISSUED FOR PERMIT BUS BAR I I EXTERIOR UNIT BONDS: METALLIC OBJECTS, EXTERNAL TO OR MOUNTED TO THE BUILDING, SHALL BE BONDED 2 11-30-21 ISSUM FOR PERMIT 6"x2" GROUND O TO THE EXTERIOR GROUND RING. USING #2 TINNED SOLID COPPER WIRE BUS BAR EXISTING MAST ICE BRIDGE SUPPORTS: EACH ICE BRIDGE LEG SHALL BE BONDED TO THE GROUND RING WITH #2 AWG BARE OTINNED COPPER CONDUCTOR. PROVIDE EXOTHERMIC WELDS AT BOTH THE ICE BRIDGE LEG AND BURIED ROUND MEMBER GROUND RING. A&E PROJECT NUMBER ADAPTER STAINLESS STEEL I DURING ALL DC POWER SYSTEM CHANGES INCLUDING DC SYSTEM CHANGE OUTS, RECTIFIER REPLACEMENTS STAINLESS STEEL HOSE CLAMP I I COPPER GREEN DED OR ADDITIONS, BREAKER DISTRIBUTION CHANGES, BATTERY ADDITIONS, BATTERY REPLACEMENTS AND NYNYCO2239A HOSE CLAMP 6"x2" GROUND BUS BAR INSULATED (TYPO INSTALLATIONS OR CHANGES TO DC CONVERTER SYSTEMS IT SHALL BE REQUIRED THAT SERVICE (TOTAL OF 1) O CONTRACTORS VERIFY ALL DC POWER SYSTEMS ARE EQUIPPED WITH A MASTER DC SYSTEM RETURN GROUND DISH WIRELESS PROJECT INFORMATION CONDUCTOR FROM THE DC POWER SYSTEM COMMON RETURN BUS DIRECTLY CONNECTED TO THE CELL SITE REFERENCE GROUND BAR N Y N Y C 0 2 2 3 9 A OTOWER TOP COLLECTOR BUSS BAR IS TO BE MECHANICALLY BONDED TO PROPOSED ANTENNA MOUNT COLLAR. 61405 MAIN ROADR0UTE 25 REFER TO DISH Wireless LLC L.L.C. GROUNDING NOTES. ' SOUTHOLD, NY 11971 BUSS BAR PLAN BUSS BAR ELEVATION ANTENNA GROUNDING ELEVATION SHEET TITLE GROUNDING PLANS AND NOTES SHEET NUMBER G=1 TYPICAL ANTENNA GROUNDING DETAIL NO SCALE 2 GROUNDING KEY NOTES NO SCALE 3 DISH Wireless LLC. TEMPLATE VERSION 34 - 06/11/2021 NOTES NOTES EQUIPMENT CABINET OMITTED FOR CLARITY CABLE GROUNDING HE REQUIRED WHEN 0 PROPOSED GPS UNIT ANTENNA IS LESS THAN 10' FROM CABINET PROPOSED 200AMP METER SOCKET : —�---- ----------------- ---------------� PROPOSED GPS UNIT 1 I � 1 l.- ----- -------------- JWLi ..LWDS TM LLC o o PROPOSED PIPE COLUMN i PROPOSED POST ____ J2 AWG GROUND I CONDUCTOR TO GROUND 5701 SOUTH SANTA FE DRIVE ---- LITTLETON, CO PROPOSED GPS UNIT 80120 MOUNT OR APPROVED i PROPOSED PIPE CLAMPS 1 j EQUIVALENT 01 1 PROPOSED DISH I I Wireless LLC I ®�••,® LLC. POWER PROTECTIVE 0 CAB`NET I I I RESERVED SPACE FIBER I 0 0 t� NID, IF REQUIRED =L __--a--- ------------ �, b 1/2 COAX CABLE 8 IM uTH MINIMUM BENDING RADIUSx ,Q ,, p ` PER CABLE MANUFACTURER'S --------- SPECIFICATIONS ` y ( �+---------- TO GROUND __ 695 ROUTE 46 WEST, SUITE 300 PROPOSED Ili FAIRFIELD, NJ 07004 No SCALE ; ;j; 01Ii"cL�c.s lI;{ �j� TYPICAL GPS UNIT GROUNDING No SCALE 2 I ,� I ♦1 I I I c SAFETY SWITCH. � ISI I ♦ III I REQUIRED IBYI� lil i l LOCAL UTILITY/ COMPANY I i III j' I I I PROPOSED TELCO FIBER ENCLOSURE L-----t---- J.A / l pE T% J ♦ �� � I c, � o It 0 PROPOSED #2 AWG TIE �Q N 1 1 ' 1 1 , ♦ IIS I INTO GROUND RING )o ,., \\ 1 1 I /fiR V ' I I I PROPOSED PLATFORM .01, El �i \ NEW YO SIONAL #2 TINNED SOLID IN 1/2" MIN. LIQUIDi 0 ® C= BUSS O O O E� 0 � � 0 \; ENGINEE - L :095374-1 TIGHT CONDUIT FROM 24 BELOW GRAD TO WITHIN 3" TO 6" OF CAD—WELD o c o BAR r100000c o 0 0 1 IT IS A VIIOLATION OF LAW FOR ANY PERSON, TERAS"NATION POINT. EXPOSED END OFUlf THE LIQUID' TIGHT CONDUIT EN MUST BE ( BOND EQUIPMT UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, SEALED WITH SILICONE CAULK. (TV) i GROUND BAR TO j ; I►-�--�i I 1 1 ; GROUNDING i 1 TO ALTER THIS DOCUMENT. ELECTRODE i rL—J, I 1 i I I I I PROPOSED GROUND RING DRAWN BY: CHECKED BY: APPROVED BY: I SYSTEM (Typ) --I �i ` —I J � i 00 I I 00 MDC JAA JKM i --=------�.—.`----�--------=----._�.�,I----- �� ._._ BASE CONNECTION RFDS REV #: 3 PROPOSED GROUND RING 2GROUN PRELIMINARY DOCUMENTS H—FRAME GROUNDING DETAIL No SCALE OUTDOOR CABINET GROUNDING No SCALE 3 SUBMITTALS REV DATE DESCRIPTION 12" DIA x 24" DEEP A 05-23-21 MAUL SUBMWM TIGHr2 TINNSOLID IN 1/2m MIN. LIQUID IOR SOIL NSPECTION E WITHEEVE CAP PVC O 09-20-21 W= FOR PUNIT r ED CONDUIT FROM 24" BELOW GRADE OR EQUIVALENT 1 11-05-21 M FOR PEW TO WITHIN 3" TO 6" OF CAD—WELD PIPE ,� 1' MM TERMINATION POINT. EXPOSED END OF i 04 2 11-30-21 W= FOR POW THE LIQUID TIGHT CONDUIT MUST BE i FINISHED GRADE SEALED WITH SILICONE CAULK. INCLUDE WARNING TAPE WITH i . .p. . p . p. . p . p. . p , p. . p . p. p. .p. . .'.O .o o. b,.'-O .o o, . .'.O .o.� o D o.. -O .6'9 o.- :D: o.1'0-0 9i c BACKFILL PER SPECIFICATIONS (o. p.'•O .p'9. p.' O .p'�. p. 0 . p. p'�. p. .D .p'�. p. O .p'0.�. 0 GRADE 3 .O D. 'p. I .O . .D, .':O o o . .0. .O id m z_ ���\ \\ \\ \\ \\ \\/ /\\/\\/\\/ \ � � A&E PROJECT NUMBER to NYNYCO2239A i EXOTHERMIC CONNECTION \ ZO �/%�\� =N DISH WIRELESS PROJECT INFORMATION 3/4" CRUSHED STONE OR EQUAL FILL TEST WELL TO qR INYNYCO2239A WITHIN 2 OF TOP OF GROUNDING LOOP CONDUCTOR v GROUND RING, #2 AWG 61405 MAIN ROAD, ROUTE 25 SOLID BARE TINNED SO►UTHOLD, NY 11971 CADWEL (lYP) 1 I I GROUND RING COPPER CONDUCTOR SHEET TITLE TIE INTO EXISTING COPPER SOLID GROUNDING DETAILS GROUND RING EXTERIOR GROUND RING GROUND ROD, 1/2" MIN. x 8'-0" LONG COPPER CLAD STEEL (ERICO (625880) SHEET NUMBER G=2 TRANSITIONING GROUND DETAIL No SCALE 4 TYPICAL TEST GROUND ROD WITH INSPECTION SLEEVE NO SCALE 5 TYPICAL GROUND RING TRENCH No SCALE 6 DISH Wireless LLC. TEMPLATE VERSION 34 — 06/11/2021 G 1. EXOTHERMIC WELD (2) TWO, #2 AWG BARE TINNED SOLID COPPER CONDUCTORS TO GROUND BAR. ROUTE CONDUCTORS TO BURIED GROUND RING AND PROVIDE PARALLEL EXOTHERMIC WELD. w NOTE: MINIMUM OF 3 THREADS S/S BOLT (TYP) TO BE VISIBLE (TYP) 2. ALL EXTERIOR GROUNDING HARDWARE SHALL BE STAINLESS STEEL 3/8" DIAMETER OR LARGER. 12" MIN S/S SPLIT WASHER (TYP) ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING LOCK WASHERS, COAT ALL SURFACES WITH AN ANTI—OXIDANT COMPOUND BEFORE MATING. N S/S FLAT WASHER (TYP) HYBRID CABLE N "" L L C 3. FOR GROUND BOND TO STEEL ONLY: COAT ALL SURFACES WITH AN ANTI—OXIDANT COMPOUND BEFORE: MATING. \\F— 2 HOLE LONG BARREL 4. DO N0� INSTALL CABLE GROUNDING KIT AT A BEND AND ALWAYS DIRECT GROUND CONDUCTOR TINNED SOLID COPPER 5701 SOUTH SANTA FE DRIVE DOWN 'f0 GROUNDING BUS. -.,� LUG (TYP) LITTLETON, CO 80120 'A S/S FLAT WASHER (TYP) 5. NUT & WASHER SHALL BE PLACED ON THE FRONT SIDE OF THE GROUND BAR AND BOLTED ON WEATHERPROOFING KIT TIN COATED SOLID THE BACK SIDE. (SEE NOTE 3) COPPER BUS BAR S/S NUT (TYP) 6. ALL GF;OUNDING PARTS AND EQUIPMENT TO BE SUPPLIED AND INSTALLED BY CONTRACTOR. � CABLE GROUNDING KR CHERRY INSULATOR 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ADDITIONAL GROUND BAR AS INSTALLED IF REQUIRED REQUIRED. 6 AWG STRANDED COPPER THWS. ENSURETHE WIRE INSULATION TERMINATION IS WITHIN 1/8" OF THE BARREL (NO SHINERS). CONDUCTOR WITH DED TO INSULATION GROUNDED TO GROUND BAR (SEE NOTES 1 & 2) 0 1w 0 KAUTH 695 ROUTE 46 WEST, SUITE 300 CONNECTION OF HYBRID CABLE GROUNDING KIT FAIRFIELD, NJ 07004 TYPICAL GROUNDING NOTES No SCALE � TO HYBRID TRUNK N0 SCAB 2 LUG DETAIL No SCALE 3 MONOPOLE EXTERNAL INSPECTION WINDOW IN CLEAR HEAT CONDUCTOR INSULATION TO EXTERNAL CLOSED BARREL, FOR ALL BLACK HEAT CONDUCTOR INSULATION TO TOOTHED BARREL, REQUIRED FOR SHRINK BUTT UP AGAINST THE TOOTHED EXTERIOR TWO—HOLE SHRINK W BUTT UP AGAINST THE ALL INTERIOR TWO—HOLE CONNECTOR BARREL CONNECTORS CONNECTORS RATED CONNECTOR BARREL „ .- 3/8" DIA xi 1/2" 3/8" DIA x1 1/2- #6 6 STRANDED CU WIRE WITH PROPOSED UPPER GROUND ���1 GREEN, 600V, THWNHol BAR LOCATED AT MCL �P K M �9 INSULATION OR AS PROVIDED*:802 2 t (BONDED TO TOWER STEEL) S/S NUT S/S NUT WITH GROUND KIT) (TYP) S/S LOCK S/S LOCK WASHER WASHER --- ——————— R NEW PROPOSED HYBRID TO I S/S FLAT S/S FIAT NG NEEER- L RS0955374LI ANTENNA (TYP) WASHER WASHER �1:1J TINNED COPPER TINNED COPPER --- ------- IT IS A VIOLATION OF LAW FOR ANY PERSON, S/S FIAT GROUNDING BAR ——— ——————— S/S FLAT GROUNDING BAR --- ------- UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, WASHER � WASHER— � TO ALTER THIS DOCUMENT. EXISTING MONOPOLE !1J --- ——————— S/S BOLT S/S BOLT DRAWN BY: CHECKED BY: APPROVED BY: (1 OF 2) (1 OF 2) MDC JAA JKM 1/16" MINIMUM SPACING 1/16" M"NIMUM SPACING RFDS REV #: 3 #6 AWG 2 HOLE LUG (TYP) PRELIMINARY HYBRID (TYP FOR) DOCUMENTS TTRRBTS AY ORE CEIPMENT BRIDGE� TYPICAL INTERIOR TWO HOLE LUG No SCALE TYPICAL EXTERIOR TWO HOLE LUG No SCALE 5 6 SUBMITTALS I REV DATE DESCRIPTION EXISTING GROUND WIRE A 08-23-21 INITIAL. SUBMWION 0 09-20-21 ISSUED FOR PERWT EXISTING TOWER PIER/ 1 11-05-21 ISSUED FOR PERMIT FOOTING 2 11-30-21 MSM FOR PERMIT GRADE INSPECTION WELL ' A&E PROJECT NUMBER / EXISTING GROUND RING NYNYCO2239A DISH WIRELESS PROJECT INFORMATION I I NYNYCO2239A I 61405 MAIN ROAD, ROUTE 25 SOUTHOLD, NY 11971 NOTES: SHEET TITLE 1. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO TOWERS. ALL MECHANICAL GROUNDING DETAILS CONNECTIONS SHALL BE TREATED WITH AN ANTI—OXIDANT COATING. 2. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED SHEET NUMBER EDITION OF ANSI/M 222 AND NFPA 780. G=3 TYPICAL ANTENNA CABLE GROUNDING No SCALE 4 NOT USED No SCALE $ NOT USED No SCALE g DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 LOW BANDS (N71+N26) AWS HYBRID/DISCREET CABLES 3/4" TAPE WIDTHS WITH 3/4" SPACING OPTIONAL. — (N29) (N66+N70+H—BLOCK) ORANGE PURPLE ALPHA RRH. BETA RRH GAMMA RRH LOW—BAND RRH (600 MHz N71 BASEBAND) + PORT 1 PORT 2 PORT 3 PORT 4 PORT 1 PORT 2 PORT 3 PORT 4 PORT 1 PORT 2 PORT 3 PORT 4 + SLANT — SLANT + SLANT — SLANT + SLANT — SLANT + SLANT — SLANT + SLANT — SLANT + SLANT — SLANT (850 MHz N26 BAND) + LLC 777 TM (700 MHz N29 BAND) — OPTIONAL PER MARKET �_... w UE BLUE GREEN GREEN GREEN GREEN CBRS TECH NEGATIVE SLANT PORT 5701 SOUTH SANTA FE DRIVE RED RED RED RED BLUE BLUE BL ADD FREQUENCY COLOR TO SECTOR BAND LITTLETON, CO 80120 (CBRS WILL USE YELLOW BAND) # 7 (3 GHz) ON ANT/RRH ,.. r�.. ORANGE ORANGE RED RED ORANGE ORANGE BLUE BLUE ORANGE ORANGE GREEN GREEN YELLOW WHITE °r A Y I P ORANGE ORANGE _ �� ORANGE ORANGE _ p ORANGE ORANGE r■� ALPHA SECTOR BETA SECTOR GAMMA SECTOR -777-77 MID—BAND RRH RED' VRE6 RED RED BLUE BLUE BLUE` BLUE GREEN GREEN GREEN GREEN RED BLUE GREEN (AWS BANDS N66+N70) I MTH ADD FREQUENCY COLOR TO SECTOR BAND �-�� � (CBRS WILL USE YELLOW BANDS) PURPLE RED RED PURPLE PURPLE BLUE BLUE PURPLE PURPLE GREEN GREEN 7777 77777 695 ROUTE 46 WEST, SUITE 300 PURPLE PURPLE _ B� PURPLE PURPLE PURPLE PURPLE FAIRFIELD, NJ 07004 . IDENTIFIER 2 — — HYBRID/DISCREET CABLES EXAMPLE 1 EXAMPLE 2 EXAMPLE 3 CANISTER COAX#1 COAX #2 INCLUDE SECTOR BANDS BEING SUPPORTED (ALPHA) (ALPHA) ALONG WITH FREQUENCY BANDS. EXAMPLE 1 — HYBRID, OR DISCREET, SUPPORTS "� �'��: ✓�9 ALL SECTORS, BOTH LOW—BANDS AND RED RED REO RED MID—BANDS. BLUE BLUE �QNQK r EXAMPLE 2 — HYBRID, OR DISCREET, SUPPORTS GREEN GREEN RED CBRS ONLY, ALL SECTORS. ` �' ► L_� EXAMPLE 3 — MAIN COAX WITH GROUND ORANGE YELLOW p MOUNTED RRHs. NEW PURPLE ENGINEER ORKLICE ER:095374-1 IT IS A VIOLATION OF LAW FOR ANY PERSON, FIBER JUMPERS TO RRHs LOW BAND RRH MID BAND RRH LOW BAND RRH MID BAND RRH LOW BAND RRH MID BAND RRH UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LOW—BAND HHR FIBER CABLES HAVE SECTOR ` TO ALTER THIS DOCUMENT. STRIPE ONLY. RED RED BLUE BLUE GREEN GREEN DRAWN BY: CHECKED BY: APPROVED BY: ORANGE PURPLE ORANGE PURPLE ORANGE PURPLE MDC JAA JKM POWER CABLES TO RRHs LOW BAND RRH MID BAND RRH LOW BAND RRH MID BAND RRH LOW BAND RRH MID BAND RRH RFDS REV #: 3 LOW—BAND RRH POWER CABLES HAVE SECTOR b PRELIMINARY STRIPE 0 N LY RED RED BLUE BLUE GREEN GREEN DOCUMENTS ORANGE PURPLE ORANGE PURPLE ORANGE PURPLE NOT USED 3 SUBMITTALS REV DATE DESCRIPTION RET MOTORS AT ANTENNAS ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 A 05—,23-21 INITW. SLRWIS" MID BAND LOW BAND MID BAND LOW BAND MID BAND LOW BAND 0 OA-20-21 ISSUM FOR PERMIT RET CONTROL IS HANDLED BY THE MID—BAND IN IN IN IN IN IN 1 11_tA5-21 �l1® FOR F�ERI�I�T RRH WHEN ONE SET OF RET PORTS EXIST ON ANTENNA. 2 11-30-21 ISSU® FOR PERMIT SEPARATE RET CABLES ARE USED WHEN RED RED BLUE BLUE GREEN GREEN ANTENNA PORTS PROVIDE INPUTS FOR BOTH LOW AND MID BANDS. PURPLE ORANGE PURPLE ORANGE PURPLE ORANGE A&E PROJECT NUMBER MICROWAVE RADIO LINKS FORWARD AZIMUTH OF 0-120 DEGREES FORWARD AZIMUTH OF 120-240 DEGREES FORWARD AZIMUTH OF 240-359 DEGREES NYNYCO2239A PRIMARY SECONDARY PRIMARY SECONDARY PRIMARY SECONDARY LINKS WILL HAVE A 1 .5-2 INCH WHITE WRAP DISH WIRELESS PROJECT INFORMATION WITH THE AZIMUTH COLOR OVERLAPPING IN THE MIDDLE. � NYNYCO2239A ADD ADDITIONAL SECTOR COLOR BANDS FOR WHITE WHITE WHITE WHITE WHITE WHITE A ADDITIONAL MW RADIO. RED RED BLUE BLUE GREEN GREEN 61405 MAIN ROAD, ROUTE 25 MICROWAVE CABLES WILL REQUIRE P—TOUCH WHITE WHITE WHITE WHITE WHITE WHITE SOUTHOLD, NY 11971 LABELS INSIDE THE CABINET TO IDENTIFY THE RED BLUE "'` GREEN LOCAL AND REMOTE SITE ID's. WHITE WHITE WHITE SHEET TITLE RF CABLE COLOR CODE SHEET NUMBER RI' CABLE COLOR CODES NOT USED 4 1 G =3 DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 EXOTHERMIC CONNECTION ® AB ANCHOR BOLT IN INCH ` ABV ABOVE INT INTERIOR ' G MECHANICAL CONNECTION AC ALTERNATING CURRENT LBS POUNDS BUSS BAR INSULATOR ® ADDL ADDITIONAL LF LINEAR FEETAr CHEMICAL ELECTROLYTIC GROUNDING SYSTEM ® AFF ABOVE FINISHED FLOOR LTE LONG TERM EVOLUTION AFG ABOVE FINISHED GRADE MAS MASONRY TEST CHEMI(X ELECTROLYTIC GROUNDING SYSTEM ®T AGL ABOVE GROUND LEVEL MAX MAXIMUM EXOTHERMIC WITH INSPECTION SLEEVE ® AIC AMPERAGE INTERRUPTION CAPACITY MB MACHINE BOLT 'yftLjlWZT.ALUM ALUMINUM MECH MECHANICAL � LLC GROUNDING BAR � ALT ALTERNATE MFR MANUFACTURER GROUND ROD ��� ANT ANTENNA MGB MASTER GROUND BAR 5701 SOUTH SANTA FE DRIVE TEST GROUND ROD WITH INSPECTION SLEEVE 1II-OT APPROX APPROXIMATE MIN MINIMUM LITTLETON, CO 80120 ARCH ARCHITECTURAL MISC MISCELLANEOUS SINGLE POU: SWITCH ATS AUTOMATIC TRANSFER SWITCH MTL METAL AWG AMERICAN WIRE GAUGE MTS MANUAL TRANSFER SWITCH DUPLEX RECEPTACLE BATT BATTERY MW MICROWAVE BLDG BUILDING NEC NATIONAL ELECTRIC CODE DUPLEX GFCI RECEPTACLE BLK BLOCK NM NEWTON METERS BLKG BLOCKING NO. NUMBER FLUORESCENT LIGHTING FIXTURE (2) TWO LAMPS 48—T8 r BM BEAMNUMBER F BTCE TINNED COPPER CONDUCTOR �—————� BAR NTS NOT TO SCALE fivi SMOKE DETECTION (DC) SD BOF BOTTOM OF FOOTING OC ON—CENTER CAB CABINET OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION EMERGENCY LIGHTING (DC) CANT CANTILEVERED OPNG OPENING 695 ROUTE 46 WEST, SUITE 300 � CHG CHARGING P/C PRECAST CONCRETE FAIRFIELD, NJ 07004 SECURITY LIGHT W/PHOTOCELL LITHONIA ALM CLG CEILING PCS PERSONAL COMMUNICATION SERVICES LED-1-25A400/51 K—SR4-120—PE—DDBTXD CLR CLEAR PCU PRIMARY CONTROL UNIT CHAIN LINK FENCE X X X X COL COLUMN PRC PRIMARY RADIO CABINET COMM COMMON pp POLARIZING PRESERVING WOOD/WROUIGHT IRON FENCE 0 0 CONC CONCRETE PSF POUNDS PER SQUARE FOOT WALL STRUCTURE CONSTR CONSTRUCTION PSI POUNDS PER SQUARE INCH LEASE AREA _ _ _ _ DBL DOUBLE DC DIRECT CURRENT PT PRESSURE TREATED PWR POWER CABINET PROPERTY LJNE (PL) — — — — — — DEPT DEPARTMENTP�F _' SETBACKS - - - -- - - - - - - - - - - - - - - - - - - - - DF DOUGLAS FIR QTY QUANTITY 5 �- RAD RADIUS DIA DIAMETER ICE BRIDGE DIAG DIAGONAL REIT RECTIFIER _ REF REFERENCE CABLE TRAY DIM DIMENSION REINF REINFORCEMENT ERS N WATER UNE W� W� W W Wj� DWG DRAWING REQ'D REQUIRED NEW YO s S 10.NAL DWI„ DOWEL ENGINEER- L 13ER:095374-1 UNDERGROUND POWER UGP UGP UGP UGP UGP EA EACH RET REMOTE ELECTRIC TILT UNDERGROUND TELCO UGT UGT UGT UGT UGT EC ELECTRICAL CONDUCTOR RF RADIO FREQUENCY IT IS A VIOLATION OF LAW FOR ANY PERSON, • RMC RIGID METALLIC CONDUIT UNLESS THEY ARE ACTING UNDER THE DIRECTION OVERHEAD POWER OHP OHP----OHP OHP--- EL ELEVATION OF A LICENSED PROFESSIONAL ENGINEER, ELEC ELECTRICAL RRH REMOTE RADIO HEAD TO ALTER THIS DOCUMENT. OVERHEAD TELCO OHT OHT—OHT—OHT- METALLIC REMOTE RADIO UNIT EMT ELECTRICAL METAC TUBING UNDERGROUND TELCO/POWER UGT/P UGT/P UGT/P UGT/P ENG ENGINEER RWY RACEWAY DRAWN BY: CHECKED BY: APPROVED BY: EQ EQUAL SCH SCHEDULE MDC JAA JKM ABOVE GROUND POWER AGP AGP AGP AGP AGP EXP EXPANSION SHT SHEET ABOVE GROUND TELCO AGT AGT AGT ACT AGT EXT EXTERIOR SIAD SMART INTEGRATED ACCESS DEVICE RFDS REV #: 3 ABOVE GROUND TELCO/POWER AGT/P AGT/P SIM SIMILAR PRELIMINARY AGT/P AGT/P EW EACH WAY SPEC SPECIFICATION FAB FABRICATION WORKPOINT W.P. FF FINISH FLOOR SQ SQUARE DOCUMENTS SS STAINLESS STEEL SECTION REI=ERENCE � FG FINISH GRADE Sm STANDARD X—X FlF FACILITY INTERFACE FRAME SUBMITTALS FIN FINISH(ED) �P TEMPORARY STEEL REV DATE DESCRIPTION FLR FLOOR THK THICKNESS A 08-2.3•-21 *MX SUNW1011 DETAIL REFERENCE FDN FOUNDATION TMA TOWER MOUNTED AMPLIFIER 0 09-20-21 ISSUED FOR PETIT FOC FACE OF CONCRETE TN TOE NAIL 1 11-05-21 ISSUED FOR PERMIT FOM FACE OF MASONRY TOA TOP OF ANTENNA 2 11-30-21 ISSU® For: PERW FOS FACE OF STUD TOC TOP OF CURB FOW FACE OF WALL TOF TOP OF FOUNDATION FS FINISH SURFACE TOP TOP OF PLATE (PARAPET) FT FOOT A&E PROJECT NUMBER FTG FOOTING TOS TOP OF STEEL GA GAUGE TOW TOP OF WALL NYNYCO2239A GEN GENERATOR TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION GFCI GROUND FAULT CIRCUIT INTERRUPTER TYP TYPICAL DISH WIRELESS PROJECT INFORMATION GLB GLUE LAMINATED BEAM UG UNDERGROUND IN Y N Y C 0 2 2 3 9 A GLV GALVANIZED UL UNDERWRITERS LABORATORY 61405 MAIN ROAD, ROUTE 25 GPS GLOBAL POSITIONING SYSTEM LINO UNLESS NOTED OTHERWISE SOUTHOLD, NY 11971 GND GROUND UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM GSM GLOBAL SYSTEM FOR MOBILE UPS UNITERRUPTIBLE POWER SYSTEM (DC POWER PLANT) HDG HOT DIPPED GALVANIZED VIF VERIFIED IN FIELD HDR HEADER W WIDE SHEET TITLE HGR HANGER W/ WITH LEGEND A N D HVAC HEAT/VENTILATION/AIR CONDITIONING WD WOOD ABBREVIATIONS HT HEIGHT WP WEATHERPROOF SHEET NUMBER IGR INTERIOR GROUND RING WT WEIGHT G lk I LEGEND ABBREVIATIONS DISH Wireless LL TEMPLATE VERSION 34 — 06/11/2021 SITE ACTIVITY REQUIREMENTS: BE PLACED IN ANY FILL OR EMBANKMENT. 1. NOTICE TO PROCEED - NO WORK SHALL COMMENCE PRIOR TO CONTRACTOR RECEIVING A WRITTEN NOTICE TO PROCEED GENERAL NOTES: 0 (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE DISH Wireless 1.FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: LLC L.L.C. AND TOWER OWNER NOC & THE DISH Wireless LLC L.L.C. AND TOWER OWNER CONSTRUCTION MANAGER. "LOOK UP" - DISH Wireless LLC L.L.C. AND TOWER OWNER SAFETY CLIMB REQUIREMENT: CONTRACTOR:GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION 2. CARRIER:DISH Wireless LLC L.L.C. THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGESTM LLC OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL TOWER OWNER.-TOWER OWNER ruft'W6 NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY THIS SHALL INCLUDE BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM 5701 SOUTH SANTA FE DRIVE THE STRUCTURE. EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE LITTLETON, CO 80120 ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR DISH Wireless LLC L.L.C. AND DISH Wireless LLC L.L.C. AND TOWER CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED OWNER POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF IS NOT LIMITED T0, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND JURISDICTIONAL REQUIREMENTS. PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. 4. Ala. CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL PLANS, MID RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF OBSERVATION OF THE FINISHED STRUCTURE ONLY. ff 11k HM_ T H THE WORD; CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING WHERE NO DETAILS ARE SHOWN CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT AND/OR AS PROVIDED FOR IN PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND DISH Wireless LLC L.L.C. AND TOWER OWNER STANDARDS, THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE 695 ROUTE 46 WEST, SUITE 300 INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF FAIRFIELD, NJ 07004 STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). RECORD. 5. ALL SITE WORK TO COMPLY WITH DISH Wireless LLC L.L.C. AND TOWER OWNER INSTALLATION STANDARDS FOR CONSTRUCTION 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST ACTIVITIES ON DISH Wireless LLC L.L.C. AND TOWER OWNER TOWER SITE AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY DISH Wireless LLC L.L.C. AND TOWER OWNER PRIOR TO PROCEEDING WITH ANY DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS SUCH CHANGE OF INSTALLATION. POSSIBLE. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS 6• PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE c') ,., K. EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS ANY AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, � REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CARRIER POC AND TOWER OWNER. OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, 7, ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACC ORDANCE WITH ALL APPLICABLE CODES, REGULATIONS ORDINANCES AND APPLICABLE REGULATIONS. AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, JER o ` N 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED NEW Y SIONAL OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ENGINEER- L 095374-1 UNLESS SPECIFICALLY STATED OTHERWISE. ORDINANCES AND APPLICABLE REGULATIONS. 9. TIHE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES INCLUDING PRIVATE LOCATES SERVICES PRIOR TO THE START g, UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR UNIT IS A LESS THEY ARE NAOF LAW FOR ANY PERSON, CTING UNDER THE DIRECTION OF CONSTRUCTION. NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. OF A LICENSED PROFESSIONAL ENGINEER, 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE TO ALTER THIS DOCUMENT. PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK SHALL BE RELOCATED AS DIRECTED BY 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS ' UNLESS SPECIFICALLY STATED OTHERWISE. DRAWN BY: CHECKED BY: APPROVED BY: CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE MDC JAA JKM FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND TOWER OWNER PRIOR TO PROCEEDING WITH ANY SUCH CHANGE REDS REV #: 3 PROCEDURES. OF INSTALLATION. 11 . ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND DISH PROJECT SPECIFICATIONS, 11 . CONTRACTOR IS TO PERFORM A SITE INVESTIGATION, BEFORE SUBMITTING BIDS, TO DETERMINE THE BEST ROUTING OF ALL PRELIMINARY LATEST APPROVED REVISION. DRAWINGS.FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DOCUMENTS 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL., DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER, REFUSE SHALL BE REMOVED FROM THE SITE AND 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY SUBMITTALS DISPOSED OF LEGALLY. DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF DISH Wireless LLC L.L.C. AND TOWER REV DATE DESCRIPTION 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE OWNER A 08-23-21 INRIAL SSSSION WORK, SHIALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS 0 09-20-21 MM MR PMIT THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF DISH Wireless LLC L.L.C. AND TOWER OWNER, AND/OR LOCAL REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 1 11-05-21 W= MR PMff UTILITIES. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY 2 11-30-21 IMM FOR PERCH 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE BASIS. REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. A&E PROJECT NUMBER 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE NYNYCO2239A APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DISH WIRELESS PROJECT INFORMATION DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. NYNYCO2239A 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF 61405 MAIN ROAD, ROUTE 25 REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. SOUTHOLD, NY 11971 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. SHEET TITLE 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS GENERAL NOTES REMOVED FROM THE EXISTING FACILITY. ANTENNAS AND RADIOS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY SHEET NUMBER BASIS. GN =2 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT DISH Wireless L.L.C. TEMPLATE VERSION 34 - 06/11/2021 CO CRETE. FOUNDATIONS. AND REINFORCING STEEL: MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. Cr 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301 , ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY-COATED SHEET AND CONSTRUCTION SPECIFICATION FOR CAST-IN-PLACE CONCRETE. STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3 (OR BETTER) FOR 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 EXTERIOR LOCATIONS. psf. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY-COATED OR NON-CORRODING; SHALL MEET OR 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. BETTER) FOR EXTERIOR LOCATIONS. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90'f AT TIME OF PLACEMENT. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2NEWEST REVISION AND BE RATED L 4. CONCRETE EXPOSED TO FREEZE-THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE 2 (NEWEST �11�1 'I� TM LLC NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. BASED OIV SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR DISH Wireless LLC L.L.C. 5701 SOUTH SANTA FE DRIVE MAXIMUM WATER-TO-CEMENT RATIO (W/C) OF 0.45. AND TOWER OWNER BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. LITTLETON, CO 80120 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. UNLESS DOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "DISH Wireless LLC L.L.C.". #4 BARS AND SMALLER 40 ksi 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. W 0,10 #5 BARS AND LARGER 60 ksi 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWING'S: • CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" • CONCRETE EXPOSED TO EARTH OR WEATHER: • #6 BARS AND LARGER 2" • TH 5 BARS AND SMALLER 1-1/2" , , y • COINCRETE NOT EXPOSED TO EARTH OR WEATHER: • SUkB AND WALLS 3/4" 695 ROUTE 46 WEST, SUITE 300 • BEAMS AND COLUMNS 1 -1/2" FAIRFIELD, NJ 07004 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. ELECTRICAL INSTALLATION NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF co`P�"�` THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT ' CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE i E . RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE NEW YO R 6F[6 ° s ONAL ENGINEER- L 169 95374-I GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR IT IS A VIOLATION OF LAW FOR ANY PERSON, EQUAL). 'THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE TO ALTER THIS DOCUMENT. CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT DRAWN BY: CHECKED BY: APPROVED BY: MDC JAA JKM 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. TIE WRAPS ARE NOT ALLOWED. REDS REV #: 3 9. &L POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. PRELIMINARY 10. :SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. DOCUMENTS 11 . POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI-CONDUCTOR, TYPE SOOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. SUBMITTALS 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE (#14 OR LARGER), WITH REV DATE DESCRIPTION TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. A 06-23-21 SUBMWION 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND 0 09_20-21 ISSUED FOR PMN BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75' C (90' C IF AVAILABLE). 1 11-05-21 ISSUED FOR PMr 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND 2 11-30-21 WM FOR POWIT NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL-CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. A&E PROJECT NUMBER 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. NYNYCO2239A 18. LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. DISH WIRELESS PROJECT INFORMATION 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE LOCATION USED. SET NYNYCO2239A SCREW FITTINGS ARE NOT ACCEPTABLE. 61405 MAIN ROAD, ROUTE 25 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. SOUTHOLD, NY 11971 21. IVIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOL.D SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). SHEET TITLE 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPS AND HANGERS. EXPLOSIVE GENERAL NOTES DEVICES (i.e. POWDER-ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE SHEET NUMBER MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT GIM =3 FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED DISH Wireless L,L»C. TEMPLATE VERSION 34 - 06/11/2021 GROUNDING NOTES: 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GESS) SHALL C1 BE BONDI_D TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 0 t 2. THE CONTRACTOR SHALL PERFORM IEEE FALL—OF—POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR d GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. I I ftl !Wp8,. LLC 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS o R BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS 5701 SOUTH SANTA FE DRIVE WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS LITTLETON, CO 80120 EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY NA SUPPORTED. A IN w0 T 11 . EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. rl,X�,.:. I ���.�Ise:� I � r�r'. 12. &L GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 695 ROUTE 46 WEST, SUITE 300 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND FAIRFIELD, NJ 07004 BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. K4ISCELLANEOUS ELECTRICAL AND NON—ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON—METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., . NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 3 " /fE F c� ON 20. /ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN /4NEW Y SSIONAL NON—METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD—WELD TERMINATION POINT. THE EXPOSED END ENGINEER- 9T R:095374-1 OF THE 1.^.ONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE IT IS A VIOLATION of LAW FOR ANY PERSON, TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO TO ALTER THIS DOCUMENT. THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROU:3 OR NONFERROUS METAL PIPING ONLY). DO NOT ATTACH GROUNDING TO FIRE SPRINKLER SYSTEM PIPES. DRAWN BY: CHECKED BY: APPROVED BY: MDC JAA JKM RFDS REV #: 3 PRELIMINARY DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 08-23-21 II M IAL SUBMISSION 0 09-20-21 ISSUED FOR F9RtrI1T 1 11-05-21 ISSUED FOR P'ERk!!T 2 11-30-21 ISSUED FOR PERMIT A&E PROJECT NUMBER NYNYCO2239A DISH WIRELESS PROJECT INFORMATION NYNYCO2239A 61405 MAIN ROAD, ROUTE 25 SOUTHOLD, NY 11971 SHEET TITLE GENERAL NOTES SHEET NUMBER G DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021