Loading...
HomeMy WebLinkAbout48310-Z t�g1�fF01 cG. Town of Southold 9/24/2023 O P.O.Box 1179 0 53095 Main Rd oy. o�yti Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44586 Date: 9/24/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 725 Terry Ln, Southold SCTM#: 473889 Sec/Block/Lot: 65.4-17 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/16/2022 pursuant to which Building Permit No. 48310 dated 9/20/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on accessoty garage as applied for. The certificate is issued to Erkan,Deniz&Kalisz,Michelle of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48310 9/18/2023 PLUMBERS CERTIFICATION DATED t ri Signature �� suFFQtK�y TOWN OF SOUTHOLD a BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48310 Date: 9/20/2022 Permission is hereby granted to: Erkan, Deniz 725 Terry Ln Southold, NY 11971 To: construct roof-mounted solar panels on accessory garage as applied for. At premises located at: 725 Terry Ln, Southold SCTM #473889 Sec/Block/Lot# 65.-1-17 Pursuant to application dated 9/16/2022 and approved by the Building Inspector. To expire on 3/21/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector oF so�ryQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlina-town.southold.ny.us Southold,NY 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Deniz Erkan Address: 725 Terry Ln city:Southold st: NY zip: 11971 Building Permit#: 48310 section: 65 Block: 1 Lot: 17 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Tesla Energy Operations License No: 51331 ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 8kW Roof Mounted PV Solar Energy System w/ (20) Tesla T400H Modules Part of a 19.6kW System Notes: Solar on Accessory Garage Inspector Signature: Date: September 18, 2023 S. Devlin-Cert Electrical Compliance Form OF SOUtyO 1 / 0 -7?_e;� 7-OM y - # # TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 7D 64 4LOU- -h"/` o�a� .r DATE S� AL3 INSPECTOR i SObTyO� . TOWN OF SOUTHOLD BUILDING DEPT. couto, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING/STRAPPING [ FINALs�I�q-✓ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR SWITCH r sO1.AR Pti' SY ¢�• �J I�_ INVERTER 1 MAXIMUM POWEk q POINT CUFtk[NT(Imp � •� POINT bOL1�GE Vinp) v MAXIMUM SYSTEM �,. VOL(nGE{VMa,c) SCURFtENI"(L cj l~ �� MAXIMUM POWER- �A POINT CURRENT (Imp) MAXIMUM POWER- � POINT VOLTAGE (Vmp MAXIMUM SYSTE '� VOLTAGE (VMax) SHORT-CIRCUIT '- CURRENT (fsc) �A i INVERTER 2 i .h s --� _ -=�• CIA ell .-� ... MAIN BREAKER INVERTERI ENERGYSTORAGE i91 t r arr s r _- al � rr ar .,y• Iw�4FfSw�w.i. ® r �f It X11 '4 ell I l I I 11 i f r I t 1 � P f 4' t. I r t . rj • ' A ri" •� r r + a, f 1 ti I Lei • THIS RESIDENCE CONTAINS A UTILITY INTERACTIVE ,� � ' � PHOTOVOLTAIC SYSTEM. IN THE EVENT OF A UTILITY OUTAGE THIS SYSTEM WILL AUTOMATICALLY DISCONNECT. IF ADDITIONAL PROTECTION IS REQUIRED: AC DISCONNECT IS LOCATED: LOAD CENTER DC DISCONNECT IS EOCATED: .y ESTOP ' FOR SERVICE CALL 688.765.2489 4 '11FA PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER, PV POWER SOUR MAXIMUM AC A OPERATING CURRENT100 MAXIMUM AC ' OPERATING VOLTAGE 240 V SERVICE 2 OF 2 AC PHOTOVOLTAIC DISCONNECT ENERGY STORAGE SYSTEM DISCONNECT lt' wry � ��� r a Y M y ml ' • N N I!^ ar n t. 1 � ' J .._..•._...-_ ._ _._ .-,-. .. -. �-..�- f --•- sem- - .. ._ ._ _ �... ` t 1 FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) ------------------------------------- FOUNDATION (2ND) 0 Z .JO ' N ROUGH FRAMING& V� 1 PLUMBING t � v INSULATION PER N.Y. STATE ENERGY CODE 1/L .� FINAL LAI ADDITIONAL COMMENTS C ta ) C, © -) �C O z �m s N lu y l-� o z � x r� d b H �o�oSUFFe/ �o TOWN OF SOUTHOLD—BUILDING DEPARTMENT "J Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 y ogv Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownnygov Date Received APPLICATION EORBUILDING PERMIT For Office Use Only t�. '; Ir II `iV/ IC � -1" PERMIT NO. Building Inspector: .e P Applications and forms must be filled out in their entirety.Incomplete applications will,not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall..be.completed. Date:9/13/2022 OWNER(S)OF P-ROPERTY: . Name: Deniz Erkan SCTM#1000- $ . -- ) _ -7 Project Address: 725 Terry Lane Southold, NY 11971 Phone#: 425-785-2774 1 Email: deniz@mineeds.com Mailing Address: 725 Terry Lane Southold, NY 11971 CONTACT PERSON: Name:Tesla Energy Operations,Inc./Anais Fernandez Mailing Address: 15 Grumman Rd West Suite 400 Bethpage, NY 11714 Phone#: 631-406-9567 Email: anafernandez@tesla.com DESIGN PROFESSIONAL INFORMATION: Name:Humphrey K. Karriuki Mailing Address: 4129 Brittany Drive Ellicott City MD 21043 Phone#: 443-416-7800 Email: hkariuki@equiluxengineers.com CONTRACTOR INFORMATION: Name: Tesla Energy Operations,lnc./Anais Fernandez Mailing Address: 15 Grumman Rd West Suite 400 Bethpage, NY 11714 Phone#:631-406-9567 Email: anafernandez@tesla.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: 20ther Solar Irg qC . $.40,135 Will the.lot be re-graded? ❑Yes 5/No Will excess fill be removed from premises? ❑Yes ]$1 No n redesigned from 31. sla ESS 27KWH 1 PROPERTY INFORMATION 10 Existing use of property: .AifM4 Intended use of property: Zone or use district in which premises is situated: Are there any covenants an� restrictions with res ect to this property? ❑Yes OSP b IF YES, PROVIDE A COPY. C eck BoxAfter.Reading: The owner%c'ontra'ctor/design piofessionel is responsible for all drainage and'storm water issues as provided by' Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE.to the Building Department for the,issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town'of Southold,Suffolk;County,New York and other appl6ble Laws;Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all'applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False,statements made herein are" punishable as a"Class,A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted B (p ' t name): AIr)Q (;��(�.� authorized Agent ❑Owner Signature of Applicant: ©ate: , /, 71Z 02- STATE OF NEW YORK) S•_ COUNTY OF Y tc t l S Froiaii nd e-z -re-314,' 6-VII- lybeing duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above nna�mmeed", / (S)he is the l a4y l'RA (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this I^ day of J O:x► 20 PATRICIA M. ZULL Notary Public NOTARY PUBLIC-STATE OF YORK No.01ZU6328662 Qualified in Suffolk County ®PERTY OWNER AUTHORIZATION My Commission Expires 06-03-20 (Where the applicant is not the owner) residing atLane— do hereby authorize —5I01 to apply on my behalf to the To n of Southold Building Department for approval as described herein. O "ignature Date r Print Owner's e 2 'YTrr:.x:,-r � ®�gffatBUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 rft o Southold, New York 11971-0959 ®� ® 0-'t Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr[@Dsoutholdtownny.gov — seand(@-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 9/13/2022 Company Name: Jason Kane Inc. Name: Jason Kane License No.: ME-37295 email: jkane@tesla.com Phone No: 516-306-0126 ❑I request an email copy of Certificate of Compliance Address.: 127 West Blvd East Rockaway,NY 11518 JOB SITE INFORMATION (All Information Required) Name: Deniz Erkan Address: 725 Terry Lane Southold, NY 11971 Cross Street: Phone No.: 425-785- 774 Bldg.Permit#: email: deniz mineeds.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) e a esla un so ar pa �s Check All That Apply: Is job ready for inspection?: ❑YES ®NO ❑Rough In ❑Final Do you need a Temp Certificate?: ©YES ENO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground []Overhead # Underground Laterals ❑1 02 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx S frf0 =� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 �- • Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 x� rogerr(c�southoldtownny.gov — sea nd6d�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 4/25/2023 Company Name: Tesla Energy Operations Inc. Electrician's Name: Jason Kane License No.: ME-51331 Elec. email: tihand@tesla.com Elec. Phone No: 516-306-0126 E I request an email copy of Certificate of Compliance Elec. Address.: 127 West Blvd East Rockaway, NY 11518 JOB SITE INFORMATION (All Information Required) Name: Deniz Erkan Address: 725 Terry Ln. Southold, NY 11971 Cross Street: Phone No.: (425)785-2774 Bldg.Permit#: 47099 , 48310 email: kbournis@gmail.com Tax Map District: 1000 Section: 65. Block: 1 Lot: 17 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of: Install of roof-mounted solar panels and energy storage system as well as roof-mounted solar panels on accy. garage Square Footage: 1,053.5 Circle All That Apply: Is job ready for inspection?: © YES [] NO F Rough In © Final Do you need a Temp Certificate?: F1 YES ❑V NO Issued On Temp Information: (All information required) Service Size 01 Ph 03 Ph Size: A # Meters Old Meter# F-1 New Service0 Fire ReconnectOFlood ReconnectOService ReconnectOUnderground DOverhead # Underground Laterals 1 n2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION �►ScvvtPtf /sA � /tw6,9*4 A..f' �'G/ate Mejia, Evelin From: Tim Hand <tihand @tesla.com> Sent: Wednesday, September 6, 2023 12:27 PM To: Mejia, Evelin Subject: RE: Open item on BP#48310 Attachments: Terry1 jpg;Terry2 jpg;Terry3 jpg;Terry4 jpg;Terry5 jpg;Terry6 jpg;Terry7 jpg;Terry?jpg; Terry8 jpg;Terry9 jpg Hey Evelin, Attached are the photos of everything labeled as requested at the first electrical inspection.As well we fixed the loose conduit that was between the load center and the inverter. Please let me know if this is sufficient to have these permits closed out and if there are any other requirements needed! Thanks again! Tim From: Mejia, Evelin<evelinm@southoldtownny.gov> Sent:Wednesday,August 30, 2023 11:23 AM To:Tim Hand <tihand@tesla.com> Subject:Open item on BP#48310 Good morning, The following are open items needed in order to close out Permit#48310 for the property located at 725 Terry Ln, Southold NY: 1. Electrical Certificate Please call to schedule Final Electrical Inspection Attached is the Final Inspection Ticket as well as the Rough Electrical Thank you Evelin Mejia Town Of Southold Building Department Annex Building 54375 Main Road Southold, NY 11971 (631)765-1802 _ 1 1 i YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured 650-963-5100 Tesla Energy Operations,Inc. 901 Page Avenue 1c.NYS Unemployment Insurance Employer Registration Numberof Fremont,CA 94538 Insured 49-892777 Work Location of Insured(Only required if coverage is specifically limitedto 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 02-0781046 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) American Zurich Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1a" 54375 Main Road WC 1074583-04 Southold, NY 11971 3c.Policy effective period 10/31/2021 to 10/31/2022 3d.The Proprietor,Partners or Executive Officers are ®Included.(Only check box if all partners/officers included)all ❑excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"forworkers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums orwithin 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Susan B. Kendziora (Print name of authorized representative or licensed agent of insurance carrier) Approved by: �ieut,r c�47 f� 10/31/2021 (Signature) (Date) Title:Vice President-Enterprise Support Operations Telephone Number of authorized representative or licensed agent of insurance carrier:800-382-2150 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C www.wcb.ny.aov -105.2(9-17) INTERNAL USE ONLY NEW I workers' YORK CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Tesla Energy Operations, Inc. 901 Page Avenue Fremont, CA 94538 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 02-0781046 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) The Prudential Insurance Company of America Town of Southold 3b.Policy Number of Entity Listed in Box"1 a" 54375 Main Road CG-51526-NY Southold, NY 11971-0959 3c.Policy effective period 01/01/2021 to 12/31/2022 4. Policy provides the following benefits: ❑X A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed November 25, 2020 By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 215-658-5178 Name and Title H Richard Brummett-Statutory Disability Coordinator IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 56 is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed BY (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) III [11111m11111°°'�(°°°1°1°!1)°�IIIII 7 ® DATE(MMIDDIYYYY) ACC>R o CERTIFICATE OF LIABILITY INSURANCE 12104/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER N,ME. Kayla Ferrell MARSH RISK& INSURANCE SERVICES PHONE 415-743-8025 FAX FOUR EMBARCADERO CENTER,SUITE 1100 AIC No C.No): CALIFORNIA LICENSE NO.0437153 E-MAIL ADDRESS: y Ka la.ferrell@marsh.com SAN FRANCISCO,CA 94111 Attn:SanFrancisco.Certs@marsh.com/FAX 212-948-0398 INSURERS AFFORDING COVERAGE NAIC# CN 104275261-STND-GAWU E-21- INSURER A:Zurich American Insurance Company16535 INSURED Tesla Energy Operations,Inc. INSURER B:Steadfast Insurance Company 26387 901 Page Avenue INSURER C:American Zurich Insurance Company 40142 Fremont,CA 94538 INSURER D:Allianz Global Risks US Insurance Company 35300 INSURER E: INSURER F COVERAGES CERTIFICATE NUMBER: SEA-003418109-28 REVISION NUMBER: 9 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDSUBR POLICY NUMBER MM/DDYY MM/DDIYYYY LIMITS LTR A X COMMERCIAL GENERAL LIABILITY GLO 1074588-04 10/3112021 10131/2022 EACH OCCURRENCE $ 2,500,000 _15A AGE To X❑OCCUR Includes Host Liquor Liability PREMISES Ea o..RENTED nc. $ CLAIMS-MADE 2,500,000 X SIR:$750,000 MED EXP(Any one person) $ 5,000 B X Tort Contrac Liab,No XCU Excl SXS-7426362-02(Excess GL- 10!31!2021 10/31/2022 PERSONAL&ADV INJURY $ 2,500,000 GEN'L AGGREGATE LIMIT APPLIES PER: Limit:$6,750,000 excess of primary GENERAL AGGREGATE $ 20,000,000 X POLICY❑jE 0 F—] LOC GL limits on right;applies to PRODUCTS-COMP/OP AGG $ 6,000,000 OTHER: Solar Products Only) $ A AUTOMOBILE LIABILITY BAP 1074586-04 10131/2021 10/3112022 CEOMaBII aEeDtSINGLE LIMIT $ 10,000,000 X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED -OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident X UMBRELLA LIAB �j OCCUR USL00544221 10131/2021 10/31/2022 EACH OCCURRENCE $ 15,000,000 EXCESS LIAB CLAIMS-MADE RETENTIONS:SEE PAGE 2 AGGREGATE $ 15,000,000 DED X RETENTION$ $ C WORKERS COMPENSATION WC 1074583-04(AOS) 10/31/2021 10/3112022 X STATUTE X OETRH- AND EMPLOYERS'LIABILITY ( ) E.L.EACH ACCIDENT $ A YIN N WC 1074584-04 MA,WI 10131!2021 1013112022 1,000,000 ANYPROPRIETOR/PARTN ER/EXECUTIVE A OFFICER/MEMBER EXCLUDED? N N/A CA XSWC EWS 1074585-04 $50M is XS 10131/2021 10/3112022 1,000,000 (Mandatory in NH) ( E.L.DISEASE-EA EMPLOYEE $ If yes,describe under $10M SIR;$1M EE/EA is XS$10M SIR) E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS below DESCRIPTION OF OPERATIONS 1 LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Evidence of insurance. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE XVI'd dale&9wMalme Se�tuieed ©1988-2016 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name CHARLES J PICARD Business Name This certifies that the nearer is duly licensed TESLA ENERGY OPERATIONS INC )y the County of suffolk License Number:HI-62556 Rosalie Drago Issued: 09/12/2019 Commissioner Expires: 09/01/2023 RECEIPT SUFFOLK COUNTY GOVERNMENT DEPARTMENT OF LABOR, LICENSING,AND CONSUMER AFFAIRS COMMISSIONER ROSALIE DRAGO P.O. BOX 6100, HAUPPAUGE, NY 11788 (631)853-4600 Today Date: 03/22/2021 Application: ME-37295 Application Type: Master Electrical License Receipt No. 421664 Payment Method Ref.Number Amount Paid Payment Date Cashier ID Comments Check 149 $400.00 03/22/2021 CHRISTI Renewal Contact Info: JASON KANE INC JASON KANE 127 WEST BLVD EAST ROCKAWAY, NY 11518 Work Description: Suffolk County Dept.of Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE Name JASON KANE • Business Name This certifies that the bearer is duly licensed JASON KANE INC by the County of suffolk License Number:ME-37295 Rosalie Drago Issued: 04/20/2005 Commissioner Expires: 04/01/2023 . o ® 1 Tesla Road,Austin,TX 78725 P 650 681 5100 F 650 681 5101 Version#95.0-1 PIL NAS May 12,2022 Certification Letter Project/Job#1192459 Project Address: Erkan Residence 725 Terry Ln Southold,NY 11971 AHJ Southold Town SC Office Bethpage Design Criteria: -Applicable Codes=Structure:2020 EBCNYS;PV:2020 RCNYS/BCNYS with 2020 NYSUCS,ASCE 7-16,and 2018 NDS -Risk Category=II V -Wind Speed=130 mph(3-s Gust-Vult),Exposure Category C,Partially/Fully Enclosed Method -Ground Snow Load=30 psf -MP1:Roof DL=10.5 psf,Roof LUSL=20.8 psf(Non-PV),Roof LUSL=14.9 psf(PV) -MP2:Roof DL=10.5 psf,Roof LUSL=20.8 psf(Non-PV),Roof LUSL=14.9 psf(PV) -MPS:Roof DL=10.5 psf,Roof LUSL=20.8 psf(Non-PV),Roof LUSL=11.5 psf(PV) Note: Per IBC 1613.1; Seismic check is not required because Ss=0.178<0.4g and Seismic Design Category(SDC)=B<D To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.Installer verification of the mounting planes noted above is required because some or all of the framing was not observed prior to the structural evaluation performed for this report. NEW �Q v KAN�A H U M P H REY Digitally signed by CO ,4� . HUMPHREY K KARIUKI K KA R I U K I� g g 45�2.05.1 04'00? * _ „t: yUJLU .rrtwrrutsAlO 1 Tesla Road,Austin,TX 78725 S L. P 650 681 5100 F 650 681 5101 Version#95.0-1 PIL NAS HARDWARE'DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Modules'Landscape Hardware-Landscape Standoff Hardware X X Spacing X X CantileverSEENY Spacing Y Y Cantilever Configuration Up6Ft DCR MP1 72" 24" 41 NA Staggered 89.5% MP2 72" 24" 41 NA Staggered 89.5% MP5 72" 24" 41 NA Staggered 89.5% Modules'Portrait Hardware-Portrait Standoff • X X Spacing X X Cantilever Y-Y Spacing Y Y Cantilever I jjjConfiguration Upfift DCR MP1 32 15" 74" NA Staggered 71.9% MP2 32" 15" 74" NA Staggered 71.9% MPS 32" 15" 74" NA Staggered 71.8% Mountina Plan Roof Pitch Qualification (Degrees) Member Evaluation Results MP1 27° Member Impact Check OK MP2 27° Member Impact Check OK MP5 37° Member Impact Check OK 4 J --"ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES COMPLY WITH ALL CODES OF A t.14 ERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED ALL WORK TO COMPLY WITH SECTION R327 OF THE ELECTRICAL O !N CODES BUILDING CONC CONCRETE DC DIRECT CURRENT POWER—CONDITIONING INVERTER. 2020 RESIDENTIAL CODE OF NYS. I�$,pEC1`IOIlI REQUIRE® AS REQUIRED AND CONDITIONS OF EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY — RECOGNIZED TESTING EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING S�I�.IG BOARD DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, SOTHaTUUMSTEES MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE APPROVED AS NOTED KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. — BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE DATE: B.P:# NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY xx PROPERTY LINE POI POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. FEE' v BY: OCCUPANCY OR PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY N'�TIFY BUILDING DEPARTMENT AT STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B). 7,"-i 802 8 A TO 4 P FOR THE USE IS UNLAWFU TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING F;:._LOWING INSPECTIONS: ATTLOPEN mCI CUITAGW WA MAX WATT 3R0WER VoVOLTAGE OR ARE RUN IN NEMA 3Rc RAINTIGHT ENCLOSURES TO ITHE FIRST ACCESSIBLE ETALLIC RACEWAYS RDC 1. =JUNDATION,- TWO REQUIRED WITHOUT CE.RTIFICATL DISCONNECTING MEANS PER ART. 690.31(E). ;_19. POURED CONCRETE 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN 2. ?UGH - FRAMING & PLUMBING OFA OCCUPANCY RELIEF-AT ALL ENTRY INTO BOXES AS REQUIRED BY C. '.SULATION UL LISTING. 4. _ ,.AL CONSTRUCTION MUST 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL COMPLETE FOR C.O. — LISTED LOCATION PROVIDED BY THE A!__ CONSTRUCTION SHALL MEET THE MANUFACTURER USING UL LISTED GROUNDING R,= QUIREMENTS OF THE CODES OF NEW !- HARDWARE. YORK STATE. NOT RESPONSIBLE FOR I II SEP 1 :6,9099 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE j DESIGN OR CONSTRUCTION ERRORS. BONDED WITH EQUIPMENT GROUND CONDUCTORS. _. dt ae ssi'61-e VICINITY MAP INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS LICENSE GENERAL NOTES - Sheet 4 UPLIFT CALCULATIONS Sheet 5 POWERWALL LOCATION *� Sheet 6 THREE LINE DIAGRAM 1. ALL WORK SHALL COMPLY WITH THE 2020 NYS Cutsheets Attached UNIFORM CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE. 3. ALL WORK SHALL COMPLY WITH THE 2020 NYS FIRE CODE. MODULE GROUNDING METHOD: ZEP SOLAR 4. ALL WORK SHALL COMPLY WITH THE 2020 BUILDING CODE OF NYS. REV BY DATE COMMENTS AHJ: Southold Town 5. ALL WORK SHALL COMPLY WITH THE 2020 REV A JSAVAI 1/20/2022 PV SYSTEM DOWNSIZED RESIDENTIAL CODE OF NYS. 6. ALL WORK SHALL COMPLY WITH THE 2020 REV B BP s/lI/zozz Modules swapped to 400W;Electrical tie-in altered UTILITY: PSE&G—Long Island EXISTING BUILDING CODE OF NYS. oil; • ii i i CONJB-1192459 0 0 CUSTOMER. DESCRIPTION: DESIGN: CONTAINED TANED L SHALL NOT BE USED FOR THE THE INFORMATION HEREIN JOB NUMBERDeniz Erkan 19.6 KW PV ARRAY Brian Park 1 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 725 Terry Ln 27 KWH ENERGY STORAGE SYSTEM T ORGANIZATION.EXCEPT N CONNECTIOPART TO OTHERS OUTSIDE THE N WITH MODULES: Southold, NY 11971 THE SALE AND USE OF THE RESPECTIVE (49) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PACE 785 2774 PAGE NAME SHEET REV: DATE PERMISSION OF TESLA INC. Multiple Inverters COVER SHEET 1 B 5/11/2022 PITCH: 270 (6:12) ARRAY PITCH:270 (6:12) NOTES:' MPI AZIMUTH:109 ARRAY AZIMUTH:109 ESS UNITS TO BE MOUNTED ON EXTERIOR MATERIAL:Comp Shingle STORY: 2 Stories WALL AND SHALL BE INSTALLED A MINIMU PITCH:27° (6:12) ARRAY PITCH:271 (6:12) OF 3' FROM ALL DOORS AND WINDOWS. LADDER ACCESS MP2 AZIMUTH:289 ARRAY AZIMUTH:289 FOR FIRE SETBACKS MATERIAL: Com Shingle STORY: 2 Stories - p g ESS UNITS SHALL MAINTAIN MINIMUM 0" OF SEPARATION BETWEEN EACH ESS U 4 PITCH: 200 (4:12) ARRAY PITCH:200 (4:12) MP4 AZIMUTH:289 ARRAY AZIMUTH:289 MATERIAL:Comp Shingle STORY. 2 Stories FS 3'Fs®dw /A) PITCH: 370(9:12) ARRAY PITCH:370 (9:12) MPS AZIMUTH:203 ARRAY AZIMUTH:203 e MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 370 (9:12) ARRAY PITCH:370 (9:12) sv MP6 AZIMUTH:23 ARRAY AZIMUTH:23 MATERIAL:Comp Shingle STORY: 2 Stories LEGEND E-STOP RSD rz 3'-10" FOR POWERWALL+ BACKUP SWITCH Q (E) UTILITY METER & WARNING LABEL IN METER SOCKEr INVERTER W/ INTEGRATED DC DISCO 'ter IDS & WARNING LABELS e� 0 ^e © /at. © AUTOMATIC RELAY S LADDER ACCESS 3'FSB ®O DOOR FOR FIRE SETBACKS / ® DC z © DC DISCONNECT & WARNING LABELS h (E)DRIVEWAY / J AC Front Of House AC DISCONNECT & WARNING LABELS ^ / / ° Q DC JUNCTION/COMBINER BOX & LABELS Sv ENERGY STORAGE SYSTEM FOR STAND / ALONE OPERA11ON OF NEW }, / / O DISTRIBUTION PANEL & LABELS LC LOAD CENTER & WARNING LABELS i� �a l �"r Sv O DEDICATED PV SYSTEM METER LU �dw s RAPID SHUTDOWN r r z STANDOFF 3"FSB LOCATIONS R ACCESS CONDUIIT RUNON EXTERIOR �F� QyMPe ORDRRE SETBACKS CONDUIT RUN ON INTERIOR GATE/FENCE sT7cucrvx v o a� Q HEAT PRODUCING VENTS ARE RED Digitally signed by �� ! INTERIOR EQUIPMENT IS DASHED HUMPHRE , HUMPHREY K KARIUKI L=J "Date-.-.2022.05.12 KARIUK ; SITE PLAN 18:2 :15-04'00' N TOTAL ARRAY AREA (SF): 1062 Scale:l/16" = 1' TOTAL ROOF AREA (SF): 3561 W E TOTAL ARRAY AREA IS a 29.84 Ol' 16' 32' PERCENT OF TOTAL ROOF AREA CONFIDENTIAL-THE INFORMATION HEREIN JOB NUMBER JB-1192459 CUSTOMER: DESCRIPTION. DESIGN. BENEFIT TD SHALL NOT EXCEPT USD FOR THE Deniz Erkan 19.6 KW PV ARRAY Brian Park T 5 L n SHALL ITOBE DISCLOS DNE IWHOLE OR IN NOR MOUNTING SYSIE61: 725 Terry Ln PART TO OTHERS OUTSIDE THE RECIPIENT'S ZS Com V4 w Flashing-Insert Y 27 KWH ENERGY STORAGE SYSTEM ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: Southold, NY 11971 THE SALE AND USE OF THE RESPECTIVE (49) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV: DATE PERMISSION OF TESLA INC. Multiple Inverters 1 425 785 2774 SITE PLAN 2 B 5/11/2022 Jobsite Specific Design Criteria Design Code ASCE 7-16 Risk Category II Table 1.5-1 Ultimate Wind Speed V—Ult 130 Fig. 1609A Exposure Category C Section 26.7 Ground Snow Load pg 30 Table 7-1 Edge Zone Width a 11.8 ft Fig. 30.3-2A to I MP Specific Design Information MP Name M131 MP2 MP5 Roofing Comp Shingle Comp Shingle Comp Shingle Standoff ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w Flashing—Insert Flashing—Insert Flashing—Insert OF t4EVj YD Pitch 27 27 37 y KAn'jq �,f. SL/RLL: PV 14.9 14.9 11.4 rG 5 . h'y SL/RLL: Non—PV 20.8 20.8 20.8 'k -D tlt z Standoff Spacing and Layout n , MP Name MP1 MP2 MP5 d p _SS`p�T Landscape X—Spacing 72 72 72 STRUCTURAL O Landscape 24 24 24 X—Cantilever Landscape Y—Spacing 41 41 41 Landscape Y—Cantilever Portrait X—Spacing 32 32 32 Portrait X—Cantilever 15 15 15 Portrait Y—Spacing 74 74 74 Portrait Y—Cantilever — — — Layout Staggered Staggered Staggered X and Y are maximums that are always relative to the structure framing that supports the PV. X is across rafters and Y is along rafters. J B-119 2 45 9 0 0 CUSTOMER. DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBEIE Deniz Erkan 19.6 KW PV ARRAY Brian ParkBENEFIT OF ANYONE TES L n CONTAINED SHALL NOT BE USED FOR THE SHALL T BE DISCLOSED ISN WHOLE OR IT TESLA N NOR MOUNTING 34SfEM: 725 Terry Ln PART To OTHERS OUTSIDE THE RECIPIENTS ZS Comp V4 wFlashing—Insert Y 27 KWH ENERGY STORAGE SYSTEM ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: Southold, NY 11971 THE SALE AND USE OF THE RESPECTIVE (49) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER, PAGE NAME SHEET: REV DAIS PERMISSION OF TESLA INC. Multiple Inverters 425 785 2774 UPLIFT CALCULATIONS 4 B 5/11/2022 NOTES: ESS UNITS TO BE MOUNTED ON EXTERIOR WALL AND SHALL BE INSTALLED A MINIMUM OF 3' FROM ALL DOORS AND WINDOWS. ESS UNITS SHALL MAINTAIN MINIMUM 10" OF SEPARATION BETWEEN EACH ESS UNIT CF NEIN YO V ANDA ryLU �'� Z W ---''�-c 10 SE .(1 UNI 5'IRI-(::IRAL0, ST ,. ~mow r•�'�..� PROPOSED POWERWAL LOCATION: I ''�-•� EXTERIOR NORTH WALL - "`!`'`•. ESS UNITS TO BE PLACED AT LEAST 3' AWAY FROM DOORS / WINDOWS `'�-•,, , SEE UL9540A DOCUMENY REGARDING SPACING BETWEEN UNITS i CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER-- JB-1192459 00 CUSTOMER DESCRIPTION: DESIGN: CONTAINED SHALL NOTUSED A INC.,THE Deniz Erkan 19.6 KW PV ARRAY Brian Park T S L n BENEFIT Of ANYONE EXCEPT TESLA NOR MI SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Com V4 w Flashing—Insert 725 Terry Ln 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION PITH MODULES: Southold, NY 11971 THE SALE AND USE OF THE RESPECTIVE (49) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESL"INC' Multiple Inverters 1 425 785 2774 POWERWALL LOCATION 5 B 5/11/2022 MAIN PANEL SPECS GENERAL NOTES PRODUCT SPECS MODULE SPECS LICENSE Panel Number.NoMatch Inv 1: DC Ungrounded 1 -(1)Powerwall+ [24OV]#1850000-OD-C/PVI Assy. 1538000-25-F - (49)Tesla#T400H Meter Number.98357771 Inv 2: DC Ungrounded PV Module, 40OW, 371.5 PTC,40MM, Black Frame,MC4/MC4-EVO2,ZEP,1ODov Underground Service Entrance 2 -(1)Powerwall+ [24OV]01850000-00-C/PM Assy. 1538000-35-F Voc: 45.3 Vpmax: 37.13 3 / Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A MAIN SERVICE PANEL E—STOP E 20OA/2P MAIN CIRCUIT BREAKER (N) 125A LOAD CENTER BUTTON P WERWALL+ 6 7 1 z (E) WIRING 13 AC DISCONNECT i VV NERGY STORAGE DG MP 1: 1x6 TESLA BACKUP SWITCH X 9 DC+/ DO+ I Z y 240° Dc/ DG MP 1: 1x7 100A 50Al2P izv D + ---- EGC-----------------� u oG r------- 3 L2r DC+ A DC+ N f DG I 5 DG G r -------_-- _ EGC , DC+ DC+ MP 2: 2x8 --------------- I Dr DG r-------- - ---I J I EGC --------------�■ ---- EGC----------------- � I I POWE ,U ALL+ (1)Conduit Kit 3/4' EMT I I ENER Y STORAGE I 11 I 10 I I z ov N L2 1-1 I OA 2P I L2 DC+ I I u 4 I TO 120/240V I i z I N DG A DG SINGLE PHASE I 8 UTILITY SERVICE f--r'-EC --- � L------- ------------------------- - EGC - -, DC+ DC+ I MP 5: 2x10 I N DG DG I GND EGC EGC --------- -----——————————————--——� I (1)Conduit Kit; 1"PVC,Sch.40 I I (E) LOADS EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO 64 FEET TRENCH THROUGH SOFTSCAPE PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. (E) 200A DISTRIBUTION PANEL Up to (3) Powerwall+ units can be wired to the emergency stop button (e-stop) for rapid shutdown initiation. Low voltage Voc* = MAX VOC AT MIN TEMP wiring of connection(s) to additional units is not shown. GD Please see MCI wiring detail page for more information POI MGropgd Roo /tr A (2)Tesla 4J 4-STRING JUNCTION BOX D� 5r7,' x 8, Copper /`1 UNFUSED, GROUNDED,Black, Diag DIN Rail with Bracket/Cord Grip (1)1624171 Switch 1 AWG PV (19)Tesla MCI,65OV,12A Backup Switch { ) #8, THWN-2 Black -(I)AWG#8 1HWN-2, White -(1)Eaton 204 MS68 O c3 (1)AWG�, 1HWN-2, Red B-Line Meter Socket,200A, AW Hub top, Overhead, 4 lows, Ring type (I)AWG#8, THWN-$ Green EGC Vmp =240 VAC Imp=32 AAC -(3)ILSC0#IPC 4/0-2/0 -(1 Conduit Kit 3/1".[AIT . Insula!on Piercing Connector, Main 4/0-2, Tap 2/0-6 (1�AW6(f8,!1HWN-2 61ack (1)AWG jti, 711WN-2, White X (1)SL�ondECenteerr1125AAConverrUbbe,NEMA3R,12sp/24Cir,12av/240v,lOkAIC,Surface (0 PF (I)AWG�, 1HWN-2 Red -(2)SQUARE D#HOM250 (1)AWG#B, THWN-2, Green EGC VmP =240 VAC Imp=32 AAC Breaker; 50A/2P, 2 Spaces - 1 Condult Ki 3/4" EMT Y (I)CUTLER-HAMMER DS36FK r (3)AWG#2/0,THWN-2, Black (1)AWG ,THWN-2, Black Voc* 403.5 VDC Isc-22.28 ADC # r /8 = - (2)PV Wire, AWG 10 Vac =30262VDC Isc =11.14 ADC Class R Fuse Kit ©FPF-(1)AWG#6,THWN-2, Green O (1)AWG THWN-2, Red Vmp =297.04VDC Imp=21.54 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =224.78VDC Imp=10.77 ADC -(2)FERRAZ SHAWMUT 0 TR100R LLrt�_LL p- V. (1)CoLtduit (1 AWG 0 THHN ,WN-2, Green EGC- 1 Conkkrlt Ki 3 4 EMT Fuse: 100A.250 . Class RKS 2 PVC; Schedule 80 ....... .. �, .� .............(.),..... .k../�.... ......... .... ............................ ........ .. .......... -(1)CUTLER-HAMMER#DG100NB ........ ....... .................... .......... ........ .. .. (1 AWG#10,THIN)-2, Black Voc* =353.06 VDC Isc=11.14 ADC �2 PV wiir AWG 10 Voc* =353.o6VDC Isc=11.14 ADC Ground Neutral Kit; 60-100A, General Duty(DG) (1)AWG*#3,THWN-2, White ©�(1)AWG#10,THWN-2, Red Vmp =259.91 VDC Imp=10.77 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =259.91 VDC Imp=10.77 ADC -(1)CUTLER-HAMMER #DG223NRB (1)AWG#3,THWN-2, Red ....... ..(1 AWG#10f THHN/THWN-2, Green EGC, (1)ConduR Kit; 3/4'EMT Disconnect; 100A, 24OVac, Fusible, NEMA 3R .... ..... ..... ... ....... (1)AWG , THWN-2, Black 1 AWG 0,THWN- Black Vac* 302.62 VDC Isc -11.14 ADC � �* #3 ( #1 2, _ - (4)PV Wire, AWG 10 Voc =403.5 VDC Isc=11.14 ADC .70 AWG#8, THWN-2,Green -(1)Conduit,Kit; 1-1/4'EMT.. . O (1)AWG#10, THWN-2 Red Vmp =222.78VDC Imp=10.77 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =297.04VDC Imp=10.77 ADC W (1)UL 508 Emergency Stop Device- NEMA 4X (1)AWG#3, THWN-2, White 1 AWG 0 1HHN WN 2 (Peen EGC 1 Condult Ki 41 4 EMT (1)AWG#3,THWN-2, Red (1 AWG#8 THWN-2, Black Voc* =504.37VDC Isc =22.28 ADC (4)PV Wire, AWG 10 Vac* =504.37VDC Isc=11.14 ADC09' (1)AWG#3,THWN-2, Black ®�(1)AWG#8,THWN-2, Red Vmp =371.3 VDC Imp=21.54 ADC ® c^'� (1)AWG#6, Solid Bare Copper EGC Vmp =371.3 VDC Imp=10.77 ADC 1 AWG 08. - - t - 1 CONFIDENTIAL-THE INFORMATION HEREIN JOB NUMBER JB-1192459 0 0 CUSTOMER DESCRIPTION: DESGN: CONTAINED SHALL NOT BE USED FOR THE Deniz Erkan 19.6 KW PV ARRAY Brian Park T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Com V4 w Flashing—Insert 725 Terry Ln 27 KWH ENERGY STORAGE SYSTEM � PART TO OTHERS OUTSIDE THE RECIPIENT'S Southold,ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES: ouo , N Y 11971 THE SALE AND USE OF THE RESPECTIVE (49) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE: 425 785 2774 PERMISSION of TESLA INC. Multiple Inverters THREE LINE DIAGRAM 6 B 5/11/2022 OLTAIC,MNER SOURCE Label Location: Label Location: Label Location: (C)(CB)(JB) PHOTOV• (INV) SOLAR PV WITH RSYSTEM SolarEdge and,Delta M-Series and,Telsa Inverter Per Code: EQUIPPED RAPID Per Code: EQUIPPED WITH RAPID Per Code: NEC 690.31.G.3 SHUTDOWNNEC 690.56.C.3 SHUTDOWN 690.56(C)(1)(a) Label Location: 1UHHHAPID PHOTOVOLTAIC D (DC)(INV) gldDU6YN S1'ATCH TO THE DISCONNECT Per Code: "Y "POSITIONTO NEC 690.13.6 SHUTLabel Location: SMM�RM� �upAHE�s CAUTION (POI) SHOCKHAZAAD DUAL POWER SOURCEPer Code:SECN �1gHEARR�Y. • Label Location: • ; ; SOURCE IS NEC 705.12.6.3 (DC)(INV) MAXIMUM CIRCUIT CURRENT Per Code: MAX RATED OUTPUT CURRENT NEC 690.53 OF THE CHARGE CONTROLLER Label Location: OR • . . (IF INSTALLED) WARNING (POI) INVERTER Per Code: OUTPUTCONNECTION NEC 705.12.B.2.3.b ■• NOT RELOCATE Label Location: THIS OVERCURRENT WARNING (DC)(INV) DEVICE Per Code: ELECTRIC SHOCK HAZARD B IF A -• ■ . ■ NORMALLY -• ■ ■ CONDUCTORS MAY BE Label Location: UNGROUNDED AND ENERGIZEDWARNING I (DC)(INV) SHOCKELECTRIC -■ THE DC CONDUCTORS OF PHOTOVOLTAIC Label Location: UNGROUNDEDAND PHOTOVOLTAIC A (AC)(POI) MAY BE ENERGIZED DISCONNECT Per Code: NEC 690.13.B SOLAR PV SYSTEM Label Location: ABB/Delta Solivia Inverter Label Location: EQUIPPED WITH RAPID Per Code: MAXIMUM AC A (AC)(POI) SHUTDOWN 690.56(C)(1)(b) OPERATING CURRENT Per Code: TURN RAPID OPERATINGMAXIMUM AC UU NEC 690.54 SHUINN5VAICH to I Ht°cn+ in POSITIONTO3HUr ;-------; UONN CONUUI;IOHS OUTSIDETHEARRAY_ - - CONDUCTORS b fl-IN IM 1!3 Label Location: ENERGIZED IN SUNLIGHT WARNING (AC)(POI) (AC):AC Disconnect HAZARDELECTRIC SHOCK Per Code: (C): Conduit TERMINALSDO NOT TOUCH NEC 690.13.13 (CB): Combiner Box TERMINALS ON O . (D): Distribution Panel LOAD SIDES MAY BE (DC): DC Disconnect IN THE OPEN -• • (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection Label Set Label LOAD CENTER CAUTION Per Code: TRI POWER SOURCE _ Code: NEC 40 ••- + ,8 + .SECOND SOURCE IS PHOTOVOLTAIC SYSTEMNEC , THIRD SOURCE IS ENERGY STORAGE SYSTEM Label • • CAUTION DO NOT ADD NEW LOADSCode: • • Per' WARNING NEC 705.12.B.2.3.c ..- THIS EQUIPMENT FED BY Label MULTIPLE SOURCES.TOTAL RATING OF ALL OVER CURRENT CAUTION DEVICES,EXCLUDING MAIN THIS PANEL HAS SPLICED FEED- Per Code: SUPPLY OVERCURRENT DEVICE, THROUGH CONDUCTORS. NEC 312.8.A(3) SHALL NOT EXCEED AMPACITY OF BUSBAR. LOCATION OF DISCONNECT AT ENERGY STORAGE BACKUP LOAD PANEL NOMINAL ESS VOLTAGE: 12Q124OV "• Location: Label Location: (MSP) CAUTION Per Code: DUAL POWER SOURCEPer Code: CIRCUIT FROM ESS: 32A - • 7(D)label t• •- marked in field SECOND SOURCE IS ARC FAULT CLEARING ENERGY STORAGE SYSTEM 11ME FROM ESS: 67ms Label Location: DATE OF CALCULATION= ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHTPer •• Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALLPer Code: Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALLPer •• Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED INSIDEPer Code: + AC Disconnect Backup Load Center T - 5 Ln 1 � GENERAL NOTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 GD SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.B.2.1) • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ J-BOX J-BOX J-BOX J-BOX J-BOX J-BOX MCI MCI RETROFIT PV MODULES DC- • MCIS ARE LOCATED AT ROOF LEVEL, JUST UNDER THE PV MODULES IN ACCORDANCE WITH 690.12 REQUIREMENTS 1 • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH — NUMBER OF MODULES BETWEEN MCI UNITS = 0-3 — MAXIMUM NUMBER OF MODULES PER MCI UNIT = 3 J-BOX J-BOXj IJ-BOXI J-BOX — MINIMUM NUMBER MCI UNITS = MODULE COUNT/3 MCI *Exception: Tesla (Longi) modules installed in locations where the max Voc for 3 modules at low design temperature exceeds 165V shall be limited to 2 modules between MCIs. PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR O WAN, PV Wire, 60OV, Black DC MORE INFORMATION o- T - 5 Ln GENERAL MOTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.B.2.1) GD • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ DIQDE DIODE DIDDE DIODE DIDDE DIODE DIODE MCI SOLAR ROOF- TILES DC- 0 MCIS ARE LOCATED AT DECK LEVEL, JUST UNDER THE 1 DIODE DIODE DIDDE DIODE DIODE DIODE DIODE TILES IN ACCORDANCE WITH 690.12 REQUIREMENTS M� • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH — NUMBER OF TILES BETWEEN MCI UNITS = 0-10 DIODE DIODE DIODE DIODE DIDDE DIODE DIODE — MAXIMUM NUMBER OF TILES PER MCI UNIT = 10 Ma — MINIMUM NUMBER MCI. UNITS = TILE COUNT/10 DIODE DIODE DIODE DIODE PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR J) D (2)AWG, PV Wire, 600V, BlackDC MORE INFORMATION BACKUP SWITCH The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility J meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages,providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS 176 mm Model Number 1624171-xx-y Continuous Load Rating 200A,120/240V Split phase Short Circuit Current Rating 22 kA with breaker' 4 Communication ---- --- - -- ---CAN — - - - ---— TOP Product Compatibility Powerwall 2 with Backup Gateway 2, Powerwal I+ Expected Service Life 21 years Warranty 10 years Breaker size must be equal to or greater than the available fault current. 205 mm COMPLIANCE INFORMATION Safety Standards USA:UL 414,UL 2735,UL 916 CA Prop 65 Emissions FCC,ICES ENVIRONMENTAL SPECIFICATIONS Operating Temperature -400C to 50°C(-40°F to 1220F) Storage Temperature -400C to 850C(-40°F to 1850F) Enclosure Rating NEMA 3R Pollution Rating PD3 MECHANICAL SPECIFICATIONS Dimensions 176 mm x 205 mm x 74 mm (6.9 in x 8.1 in x 2.9 in) ------- ---- - ------------ --- - --------- ------- -- Weight 2.81bs Meter and Socket Compatibility ANSI Type 2S,ringless or ring type External Service Interface Contactor manual override2 Reset button Conduit Compatibility 1/2-inch NPT mm 2 Manually overrides the contactor position during a service event. T - 5 L TESLA.COM/ENERGY ^ ' POWERWALL+ PHOTOVOLTAIC (PV) AND BATTERY ENERGY MECHANICAL SPECIFICATIONS STORAGE SYSTEM (BESS) SPECIFICATIONS Dimensions 1596 x 755 x 160 mm(62.8 x 29.7 x 6.3 in) .: . ) - Powerwall+Model Number 1850000-xx-y J Total Weight 140 kg(310 Ib)' Solar Assembly Model Number 1538000-xx-y Battery Assembly 118 kg(261 Ib) Nominal Battery Energy 13.5_k Wh Solar Assembly 22 kg(49 Ib) Nominal Grid Voltage(Input/Output) 120/240 VAC Mounting options Floor or wall mount Grid Voltage Range 211.2-264 VAC 755 mm 160mm Frequency 60 Hz -- --- - Phase 240 VAC:2W+N+GND "- Maximum Continuous Power n-Grid 7.6 kVA full sun/5.8 kVA no sun' y. - z; Maximum Continuous Po er Off-Grid 9.6 kW full sun/7 kW no sun' Peak Off-Grid Power 0 s) 22 kW full sun/10 kW no sun' Maximum Contin us Current On-Grid 32 A output T E S L. t!1 Maximum Co inuous Current Off-Grid 40 A output Load Sta Capability 98-118 A LRA= T = S L Pi i PV M imum Input Voltage 600 VDC 1596 mm PV C Input Voltage Range 60-550 VDC { V DC MPPT Voltage Range 60-480 VDC MPPTs 4 $' Input Connectors per MPPT 1-2-1-2 4 v I Maximum Current per MPPT(Im•) 13 A3 1 Maximum Short Circuit 17 A3 # Current per MPPT(1,c) Allowable DC/AC Ratio 1.7 overcurrentProtection Device soAbreaker ENVIRONMENTAL SPECIFICATIONS ximum Supply Fault Current 10 kA r Operating Temperature -20°C to 500C(-40F to 1221F)' Out t Power Factor Rating +/-0.9 to 1' Round \ation y gots Recommended Temperature 0°C to 30°C(32°F to 860F) Solar GeC Efficiency 97.5%at 208 V Operating Humidity(RH) Up to 100%,condensing 98.0%at 240 V Storage Conditions -20°C to 30°C(-4°F to 860F) Up to 95%RH,non-condensinCustomTesla Mobile App g -- State of Energy(SoE):25%initial POWERWALL+ Internety Wi-Fi,Ethernet,Cellular LTE/4G)^ Maximum Elevation 3000 m(9843 ft) PV AC MRevenue grade(+/-0.5%) -- -- - - - --- - - -- - - —._ Environment Indoor and outdoor rated Protections Integrated arc fault - - --------------- -- -- ------- circuit interrupter(AFCI), Enclosure Type Type 3R Powerwall+ is an integrated solar battery system that stores energy from solar production. Powerwall+ has two ------"----- ----" —" -- ----- -- -- PV Rapid Shutdown Solar Assembly Ingress Rating IP55(Wiring Compartment) separate inverters, one for battery and one for solar, that are optimized to work together. Its integrated design and - - - ---- --- - -- - streamlined installation allow for simple connection to any home, and improved surge power capability brings whole Warranty 10 years Battery Assembly Ingress Rating IP56(Wiring Compartment) IP67(Battery&Power Electronics) home backup in a smaller package. Smart system controls enable owners to customize system behavior to suit their - - -- ---- -- - -- ----- ----- ----- -- Noise Level @ 1 m <40 db(A)optimal, renewable energy needs. COMPLIANCE INFORMATION <50db(A)maximum PV Certifications UL 1699B,UL 1741,UL 3741,UL 1741 SA.UL Values provided for 25 . Load start capability mayay vary.vary. KEY FEATURES -- — -_ 1998(US).IEEE 1547,IEEE 1547.1- - - -Where the DC input current exceeds an MPPT rating,jumpers can be used to Battery Energy Storage UL 1642,UL 1741,UL 1741 PCS,UL 1741 SA,UL allow a single MPPT to intake additional DC current up to 26 A ITr/34 A I,_ • Integrated battery, inverter, and system controller for a more compact install System Certifications 1973,UL 9540,IEEE 1547,IEEE 1547.1,UN 38.3 `Power factor rating at max real power. SAC to battery to AC,at beginning of life. • A suite of application modes, including self-powered, time-based control,and backup modes Grid Connection United States "Cellular connectivity subject to network service coverage and signal • Wi-Fi, Ethernet, and LTE connectivity with easy over-the-air updates Emissions FCC Part 15 Class B strength. 'The total weight does not include the Powerwall+bracket,which weighs an Environmental RoHS Directive 2011/65/EU additional 9 kg(20 Ib). Seismic AC156,IEEE 693-2005(high) °Performance may be de-rated at operating temperatures below 10°C(50°F) or greater than 43°C(1090F). N^-2C22-05-Oo T = S L n ,,;,� ;_��_.�,� TESLA.COII/ENERGY SOLAR SHUTDOWN DEVICE SYSTEM LAYOUTS The Tesla Solar Shutdown Device is a Mid-Circuit Powerwall+with Backup Switch Installed Behind Utility Meter Interrupter(MCI)and is part of the PV system rapid ` shutdown (RSD)function in accordance with Article 690 Onoi� of the applicable NEC. When paired with Powerwall+, solar array shutdown is initiated by pushing the System m �� Shutdown Switch if one is present. Solar Backup Switch ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS - ----- -- --- -- - --- -- -------- --- Model Number MCI-1 Electrical Connections MC4 Connector eter Nominal Input DC Current Rating(IMP) 12 A -S L. R A Housing Plastic Load center Me r socket panel Grid Maximum Input Short Circuit Current(lu) 15 A Maximum System Voltage 600 V DC Dimensions 125 mm x 150 mm x 22 mm - (5 inx6inxlin) Weight 350 g(0.77 Ib) 0Q_ S MODULE PERFORMANCE Mounting Options ZEP Home Run Clip - ------- -- - M4 Screw(u10) Powerwall+ Backup I ds Maximum Number of Devices per String - 5- - - M8 Bolt(5/16") Control Power Line Excitation Nail/Wood screw --- -------------------- ----- Passive State Normally open Maximum Power Consumption 7 W Warranty 25 years Powerwall+with Backup Switch Installed Downstr m f Utility Meter '-50 mm r COMPLIANCE INFORMATION T01:�13 crew e t------------- ----- -------------------------- ---_'------------ Certifications UL 1741 PVRSE,UL 3741, PVRSA(Photovoltaic Rapid Solar Shutdown Array) 150 mmMa Bolt Backup Switch Utility Meter 650 mm RSD Initiation Method External System Shutdown Switch Compatible Equipment See Compatibility Table below T io d Screw L� ENVIRONMENTAL SPECIFICATIONS '--- --" T=s`S yffi� Load center Meter socket panel Meter socket panel Grid Ambient Temperature -400C to 50°C(-40°F to 122°F) I Storage Temperature -30°C to 60°C(-22°F to 140°F) Enclosure Rating NEMA 4/IP65 I—� 125 mm 22 mm I I Powerwall+ Backup loads UL 3741 PV HAZARD CONTROL (AND PVRSA) COMPATIBILITY Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with the Powerwall+and Solar Shutdown Devices.See the Powerwall+Installation Manual for detailed instructions and for guidance on installing Powerwall+and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS(where xxx=405 to 450 W.increments of 5) 1 Solar Shutdown Device per 3 modules' Tesla Tesla TxxxH(where xxx=395 to 415 W,increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules 'Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. T = -- L n ��`,_,;_:�� TESLA.COM/ENERGY T - S L = ,,_,_,��_� -;)� TESLA.COM/ENERGY Powerwall+with Backup Gateway 2 for Whole Home Backup / I. Sonar n v F� Meter T L n Load center Backup Gateway 2 Meter socket panel Grid P werwa + Backup loads Powerwall+with Backup Gateway 2 for Partial Home Backup 1 / Sola T = 9 Meter Backup panel Backup Gateway 2 Meter socket panel Grid I� PO%N Backup loads -- Non-backup panel 15505D* Non-essential loads T = S L n (a, ,�"_�_ �� TESLA.COM/ENERGY Tesla Photovoltaic Module Module Specifications T395H, T400H, and T405H -- - ------ - -- - ---- -- - -- Electrical Characteristics Power ClassT395H I T400H T405H I The Tesla module is one of the most powerful residential photovoltaic Gi Test Method i STC NMOT ' STC NMOT STC NMOT modules available and exceeds industry engineering and quality standards. � Max Power,P_(W) 395 296.3 400 300.1 405 303.8 Featuring our proprietary Zep Groove design,the all-black module mounts Open Circuit Voltage,_ g E V.,(V) 45.27 42.69 45.30 42.72 45.34 42.76 close to your roof for a minimalist aesthetic.Modules are certified to IEC/ e -- - --- - - - - - - - o Short Circuit Current,Is,(A) 11.10 8.95 1U4 _-8.97 i 1117 9.00 UL 61730-1,IEC/UL 61730-2 and IEC 61215. '- --------- ------ -- -- ----- --- -------------- -------- ----- ----- ---- - - -- ---- - 35 mm/1.378 in Max Power Voltage,VM,(V) 1 36.88 35.03 37.13 35.25 1 37.39 35.46 Max Power Current,III,(A) 10.71 8.46 10.77 8.51 10,83 8.57 Module Efficiency<%) 2:20.1 >_20.4 2 20.6 STC 1000 W/m',25°C,AM1.5 NOCT 1 800 W/m2,20e C,AM1.5,wind speed 1 m/s Mechanical Loading Temperature Rating(STC) Front Side Test Load 6120 Pa 1 128lb/1`0 Refer to module and system Temperature Coefficient of Isc +0,04//°C Rear Side Test Load 6120 Pa 1 128lb/W installation manuals for Temperature Coefficient of Va -0.27//-C ----- ---- -' ---- allowable design loads,foot 1-------- ----- Front Side Design Load_ 4080 Pa 185 lb/ft'' spacings,and cantilever Temperature Coefficient of P-(W) -0.34//°C Rear Side Design Load 4080 Pa 1 85lb/ft2 specifications. Hail Test 35 mm at 27.2 m/s 1046 mm 141.2 in - - - ---'------' - --- 40+/-0.5 mm Mechanical Parameters 1.57+/_0.020 in Cell Orientation 132(6 x 22) I ,IF _.___ _. _ _____ _ _ __ -__ _.-__-_ ____-_ _ __ __ ___ _ _ SIF •IF Junction Box IP68,3 diodes Cable 4 mm-'l 12 AWG,1325 mm 147.2 in.Length Connector Staubli MC4 _ Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass "-- Frame Black Anodized Aluminum Allo Weight .- -_ -----23.5 kg 151.8 1b-----'---- ----- --- - av v 1890 mm x 1046 mm x 40 mm Dimension v E ui I E _----_-----__-- 74.41nx41.2 inx1.57 in niv m Operation Parameters E E - M Operational Temperature -40'C up to+85°C Power Output Tolerance -0/+5 W Vor&1,Tolerance +/-5% Max System Voltage DC 1000 V(IEC/UL) - Max Series Fuse Rating 20 A NOCT 45.7+/-3 eC _�- ---- ----- _ _ Safety Class Class II I Fire Rating UL 61730 Type 2 Linear Power Warranty -------- ----- ------------------------------ ----- -------------- ----------------- - ------ ---------- �, Materials and Processing 25 years -. jExtra Linear Power Output 25 years At least 98/of nominal power during first year.Thereafter max.0.5/degradation per year.At least 93.5/of nominal power up to 10 years.At least 86/of nominal power upto 25 years. e IV Curves Current vs.Voltage Power vs.Voltage Current vs.Voltage 12 r Cell Temp 25-C d50i fell Temp=25•C 12 Inci4ent lr2clian<e= 400 IODO lV/nr' 10 350 I000'rLm` l0 Cep Temp=25'C , -- - - - - ----- 8 X 600 Y//m• 300 amW/m, 8 co-,WC -1 600 Y//,+Y •j` 250'� G00\\'/m• g Cell Temp=45°C 6 400\v/m' 200 40OW/m• 6 I CCII Tcmp=SSC i4 200 w/m' o ISO: 200•///m• 4 Call Temp=65°C V 'n l00 V Cell Temp=l5°C EEA o o o L ---)- - 1. 0 to 20 30 40 s0 O 10 20 30 40 50 0 l0 20 30 40 50 vd.a9 (v) Wla (v) vd.s9 (v) Tesla Module Datasheet T = S L n Tesla Module Dalasheet T = S L n (TEPV-DS-0011-21) 0 EPV-DS-0011-21) .. @,-M,Aso ROOFING SYSTEM SPECIFICATIONS GROUND ZEP LEVELING FOOT 1 171 Listed to UL 2703 Listed to UL 2703 DESCRIPTION PV mounting solution for composition shingle roofs. Part 4850-1511 Part 9850-1397 Works with all Zep Compatible Modules. Auto bonding UL-listed hardware creates structural and electrical bond. ®41 I SPECIFICATIONS Designed for pitched roofs. Installs in portrait and landscape orientations. DC WIRE CLIP HOME RUN CLIP Engineered for spans up to 72"and cantilevers up to 24". Listed to UL 1565 Listed to UL 1565 Part#850-1509 Part#850-1510 ZS Comp has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2". Attachment method UL listed to UL 2582 for Wind Driven Rain. ZS Comp supports 50 psf(2400 Pa)front and up to 72 psf(3450 Pa)rear side design load rating for Portrait module orientation per UL 2703. 24 ZS Comp supports 50 psf(2400 Pa)front side and up to 72 psf(3450 Pa)rear side design ARRAY SKIRT F-1 END CAP load rating for Landscape module orientation. 1 Listed to UL 2703 Listed to UL 2703 Engineered for compliance with ASCE 7-05, 7-10, and 7-16 wind load requirements. Part#860-1608 Part#850-1586(Left) Part#850-1588(Right) Zep wire management products listed to UL 1565 for wire positioning devices. ZS Comp grounding products are listed to UL 2703 and UL 467. ZS Comp bonding products are listed to UL 2703. <I MOUNTING BLOCK 1-1 FLASHING INSERT SKIRT GRIP INTERLOCK Listed to UL 2703 Listed to UL 2703 and UL 2582 for Wind Driven Rain Listed to UL 2703 Listed to UL 2703 Part#850-1633 Part#850-1628 Part#850-1606 Part#850-1613 O� O F-1 CAPTURED WASHER LAG HYBRID INTERLOCK Part#850-1631-002 and#850-1631-004 Listed to UL 2703 Part#850-1281 O T = S L n ZS COMP DATASHEET 2 T = S L n ZS COMP DATASHEET 3 PV HAZARD CONTROL SYSTEM I ZS PVHCS PV HAZARD CONTROL SYSTEM PVHCS I CERTIFICATION UL 3741 REPORT DATE 10-20-21 (APPLICABLE TO ZS COMP, ZS SPAN, ZS RAMP, AND ZS SEAM) UL 3741 REPORT DATE 8-12-21 PV RAPID SHUTDOWN ARRAY, UL 1741 CATEGORY QIJR PV RAPID SHUTDOWN ARRAY, UL 1741 CATEGORY QIJR, REPORT DATE: 2021-06-11 (REV 8-10-21) WARNING:To reduce the risk of injury,read all instructions. WARNING:To reduce the risk of injury,read all instructions. PV HAZARD CONTROL EQUIPMENT AND COMPONENTS PV HAZARD CONTROL EQUIPMENT AND COMPONENTS Function Manufacturer Model No. Firmware Versions Certification Standard Firmware Versions and Checksums Function Manufacturer Model No. and Checksums Certification Standard PVRSE Mid Circuit Tesla MCI-1 N/A UL 1741 PVRSE PVRSE Mid Circuit MCI-1 Interrupter(MCI) Interrupter(MCI) Tesla 1550379' N/A UL 1741 PVRSE 7.6 kW:1538000' V4,CEA4F802 UL 1741,1998 7.6 kW:1538000' V4,CEA4F802 Inverter or Powerwall+ Testa 3.8 kW:1534000' V4,FF7BE4E1 CEA4F802 UL 1741,1998 7.6 kW:1850000' V4,CEA4F802 PVRSS/PVRSE Inverter or Powerwall+ Tesla 3.8 kW:1534000' V4, E1 7.6 kW:1850000' V4,CEA4F802 PVRSS/PVRSE Hanwha/Q-CELLS Q.PEAK DUO BLK G5/SC310-320 PV Module Tesla SR60T1,SR72T1 N/A UL 61730 PV Module Q.PEAK DUO BLK G6+/SC330-345 N/A UL 1703 SR72T2 Tesla Tesla TxxxS (xxx=405 to 450) UL 61730 Diode Harness Tesla SRDTH N/A UL 9703 Tesla TxxxH(xxx=395 to 415) (Not applicable to SR72T2) PV Wire Jumper(s) Tesla SR-BJ2X,SR-BJ3X, N/A UL 9703 PVHCS Initiator Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC 690.12 N/A SR-BJ4X,SR-BJMini (PV Inverter) requirements. Pass-Through Box Tesla SRPTB-4 N/A UL 1741 PVHCS Initiator Emergency stop device(NISD)-Listed"Emergency Stop Button"or"Emergency Stop UL 508 or UL 60947 Parts PVHCS Initiator: Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC NIA (Powerwall+) Device"or"Emergency Stop Unit". 1,5-1 and 5-5 (PV Inverter) 690.12 requirements. Applies to variations of this part number with suffix of two numbers and one letter. PVHCS Initiator: Emergency stop device(NISD)-Listed"Emergency Stop Button"or"Emergency Stop UL 508 or UL 60947 (Powerwall+) Device"or"Emergency Stop Unit" Parts 1,5-1 and 5-5 Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual equipment and component Applies to variations of this part number with suffix of two numbers and one letter. PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVHCS INSTALLATION REQUIREMENTS PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. Max System Voltage 600 VDC PVHCS INSTALLATION REQUIREMENTS PVHCS Maximum Circuit Voltage(Array Intemal Voltage After Actuation) 165 VDC(cold weather open circuit) Max System Voltage 600 VDC Max Series-Connected Modules Between MCIs: PVHCS Maximum Circuit Voltage(Array Internal Voltage After Actuation) 165 VDC(cold weather open circuit) 'Exception:Tesla S-Series(TxxxS)modules installed in locations where the max VOC for 3 3"` modules at low design temperature exceeds 165V shall be limited to 2 modules between MCIs. Max Series-Connected Panels between MCIs 10 OTHER INSTALLATION INSTRUCTIONS OTHER INSTALLATION INSTRUCTIONS 1.An MCI must be connected to one end of each series string or mounting plane sub-array string. 1.An MCI must be connected to one end of each series string or mounting plane sub-array string. 2.Verification that MCIs are installed with 3 or fewer modules between MCIs shall be documented for inspection,by voltage 2.Verification that MCIs are installed with 10 or fewer modules between MCIs shall be documented for inspection,by voltage measurement logs and/or as-built string layout diagrams. measurement logs and/or as-built string layout diagrams. 3. For PV Inverter:The PVHCS initiator(AC breaker or switch)shall be sized and installed in accordance with NEC requirements. 3.For PV Inverter:The PVHCS initiator(AC breaker or switch)shall be sized and installed in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. The specific part shall be identified on the as-built system drawings. 4. For Powerwall+:The PVHCS emergency stop initiator shall have the following minimum ratings:Outdoor(Type 3R or higher), 12V, 4.For Powerwall+:The PVHCS emergency stop initiator shall have the following minimum ratings:Outdoor(Type 3R or higher), 12V, 1A,and shall be installed in accordance with NEC requirements.The specific part shall be identified on the as-built system drawings. 1A,and shall be installed in accordance with NEC requirements.The specific part shall be identified on the as-built system drawings. Refer to the Powerwall+installation manual for further details. Refer to the Powerwall+installation manual for further details. UL UL Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its ' Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service.The Certification Mark for these products includes the UL symbol,the words"CERTIFIED"and Certification and Follow-Up Service.The Certification Mark for these products includes the UL symbol,the words"CERTIFIED"and "SAFETY,"the geographic identifier(s),and a It number. M SAFETY,"the geographic identifier(s),and a file number. T = S L n TEZS-DS-0020-21 1 T - S L `n TESR-DS-0385-21 1 DATASHEET-M22-PVT K01-BVP 10.5 Protection against electric shock Does not apply,since the entire switchgear needs to be evaluated. �� 10.6 Incorporation of switching devices and components Does not apply,since the entire switchgear needs to be evaluated. Emergency stop/emergency switching off pushbutton,RMQ-Titan,1 NC, 10.7 Internal electrical circuits and connections Is the panel builders responsibility. FMILT blister pack10.8 Connections for external conductors Is the panel builders responsibility. Part no. M22-PVT K01-BVP Powering Business Worldwide' 10.9 Insulation properties Catalog No. 132624 10.9.2 Power-frequency electric strength Is the panel builders responsibility. Alternate Catalog M22-PVT KOl-BVPQ 10.9.3 Impulse withstand voltage Is the panel builders responsibility. No. 10.9.4 Testing of enclosures made of insulating material Is the panel builders responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation.Eaton will Delivery program provide heat dissipation data for the devices. Product range RMQ-Titan 10.11 Short-circuit rating Is the panel builders responsibility.The specifications for the switchgear must be observed. Description Blister pack for hanging. 10.12 Electromagnetic compatibility Is the panel builders responsibility.The specifications for the switchgear must be Complete practical solution. Can be ordered using a single article no. observed. Connection to SmariWire-DT no 10.13 Mechanical function The device meets the requirements,provided the information in the instruction leaflet(I L)is observed. Equipment supplied 1 Emergency-stop button M22-PVT - - ....- -- - ---- - - -- - - -- —— - - - - 1 mounting clamp M22-A Technical data ETIM 7.0 1 contact element M22-KOI Low-voltage industrial components(EG000017)/Front element for mushroom push-button(EC001038) Electric engineering,automation,process control engineering/Low-voltage switch technology/Command and alarm device/Front elementfor mushroom push-button actuators Technical data (ecl@sslo.0.1-27-37-12-12JAKF0300141) General Colour button Red Ambient temperature Construction type lens Round Open °C -25-+70 Diameter cap mm 38 shipping classification DNV Hole diameter mm '225 GL LR Width opening mm 0 Heightopening mm 0 im Degree of protection(IP) IP67 � � � Degree of protection(NEMA) • Type of button High Suitable for illumination No Switching function latching Yes TYPE APPROVED Spring-return No Germanischer Lloyd With front ring No Material front ring Plastic Design verification as per IMEN 61439 Colour front ring Other Technical data for design verification Suitable for emergency stop Yes Rated operational current for specified heat dissipation In A 6 Unlocking method .Turn-release Heatdissipation per pole,current-dependent Pvid W 0.11 Equipment heat dissipation,current-dependent Pvid W 0 Additional product information(links) Static haat dissipation,non-current-dependent Pvs W 0 IL04716005ZRMQ-Titan:Emergency stop buttons,Emergency stop buttons W 0 ILD4716005ZRMQ-Titan:Emergency stop https://es-assets.eaton.com[DOCUMENTATION/A`WkINSTRUCTIONSAL@4716005Z2D20 ol.pdf Heat dissipation capacity Pdiss buttons,Emergency stop buttons Operating ambient temperature min. °C -25 �- --- `- ---- ----- -- ---- - -- I104716002Z RMQ-Titan System Operating ambient temperature max. °C 70 ILD4716002Z RMQ-Titan System https://es-assets.eaton.cam/DOCUMENTATION/AWA_INSTRUCTIONSAL04716002Z2020 09.pdf IEC/EN 61439 design verification 142 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat Meets the product standard's requirements. and fire due to internal electric effects 10.2.4 Resistance to ultra-violet(UV)radiation Please enquire 10.2.5 Lifting Does not apply,since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply,since the entire switchgear needs to be evaluated. 10.27 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply,since the entire switchgearneads to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 04IDlnD21 Eaton Industries GmbH 212 https//—.eaton.eu -- --- - -- --- -- - - - - - - — - --" ®03/2021 by Eaton Industries GmbH 0Wln021 Eaton 132624 ED2021 V17.0 EN 1/2 Eaton 132624 ED2021 V77.0 EN 1 Tesia Road,Austin,TX 78725 �r ® P 650 681 5100 F 650 681 5101 v Version#95.0-1 PIL NAS May 12,2022 Certification Letter Project/Job#1192459 Project Address: Erkan Residence 725 Terry Ln Southold,NY 11971 AHJ Southold Town SC Office Bethpage Design Criteria: -Applicable Codes=Structure:2020 EBCNYS;PV:2020 RCNYS/BCNYS with 2020 NYSUCS,ASCE 7-16,and 2018 NDS -Risk Category=II -Wind Speed=130 mph(3-s Gust-Vult),Exposure Category C,Partially/Fully Enclosed Method -Ground Snow Load=30 psf -MP1:Roof DL=10.5 psf,Roof LUSL=20.8 psf(Non-PV),Roof LUSL=14.9 psf(PV) -MP2:Roof DL=10.5 psf,Roof LUSL=20.8 psf(Non-PV),Roof LUSL=14.9 psf(PV) -MP5:Roof DL=10.5 psf,Roof LUSL=20.8 psf(Non-PV),Roof LUSL=11.5 psf(PV) Note: Per IBC 1613.1; Seismic check is not required because Ss=0.178<0.4g and Seismic Design Category(SDC)=B<D To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.Installer verification of the mounting planes noted above is required because some or all of the framing was not observed prior to the structural evaluation performed for this report. 0? NEW H U M P H R EY Digitally signed by c, ��N ., HUMPHREY K KARIUKI 2�fi n •'; t?:R K KARIUKI Date:—_ ' 022.05.12UJ 18.28.45 UJ -04 00 r^ ti: ' Fo A Ssa��� STRUCNURAL OIC ® L ® 1 Tesla Road,Austin,TX 78725 I' ® ri P 650 681 5100 F 650 681 5101 Version#95.0-1 PIL NAS HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Modules'Landscape Hardware-Landscape Standoff HardwareX X Spacing X X Cantilever Y-Y Spacing Y Y Cantilever ConfigurationJJKODDCR � MP1 72" 24" 41" NA Staggered 89.5% MP2 72" 24" 41" NA Staggered 89.5% MP5 72" 24" 41" NA Staggered 89.5% • X X Spacing X X Cantilever Y-Y Spacing Y Y Cantilever Configuration Uplift DCR M121 32" 15" 74" NA Staggered 71.9% MP2 32" 15" 74" NA Staggered 71.9% MPS 32" 15" 74" NA Staggered 71.8% Mountinci Plane Roof Pitch Qualification Results (Degrees) Member Evaluation Results MP1 27° Member Impact Check OK MP2 27° Member Impact Check OK MP5 37° Member Impact Check OK ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED ALL WORK TO COMPLY WITH SECTION R327 OF THE BUILDING CONC CONCRETE DC DIRECT CURRENT POWER—CONDITIONING INVERTER. 2020 RESIDENTIAL CODE OF NYS. EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY — RECOGNIZED TESTING EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PROPERTY LINE POI POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B). TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 313 NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL — LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. FP 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. VICINITY MAP INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS • Sheet 4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES Sheet 5 POWERWALL LOCATION ' Sheet 6 THREE LINE DIAGRAM 1. ALL WORK SHALL COMPLY WITH THE 2020 NYS Cutsheets Attached UNIFORM CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE. 3. ALL WORK SHALL COMPLY WITH THE 2020 NYS y, FIRE CODE. MODULE GROUNDING METHOD: ZEP SOLAR 4. ALL WORK SHALL COMPLY WITH THE 2020 , BUILDING CODE OF NYS. REV BY DATE COMMENTS AHJ: Southold Town 5. ALL WORK SHALL COMPLY WITH THE 2020 REV A )SAVAI 1/20/2022 PV SYSTEM DOWNSIZED RESIDENTIAL CODE OF NYS. REV B BP 5/11/2022 Modules swapped to 40OW;Electrical tie-in altered 6. ALL WORK SHALL COMPLY WITH THE 2020 UTILITY: PSE&G—Long Island EXISTING BUILDING CODE OF NYS. — • �• s - • _ JB-1192459 0 0 CUSTOMER DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN pB NUMBERDeniz Erkan 19.6 KW PV ARRAY Brian Park T 5 L n CONTAINED SHALL NOT BE USED FOR THE � � BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL O BE DISCLOSED E WHOLE OR N ZS Com V4 w Flashing—Insert 725 Terry Ln 27 KWH ENERGY STORAGE SYSTEM PART IZ OTHERS OUTSIDE ON RECIPIENTS Southold, NY 11971 ORGANIZATION,EXCEPT IN CONNECTION WITH MOOIMES THE SALE AND USE OF THE RESPECTIVE (49) Tesla # T400H PAGE NAME: SHEET; REV: DATE: TESLA PERMEQUIISSION TE LA INC. THE WRITTEN INVERTB: 425 785 2774 1 B 5/11/2022 PERMISSION OF TESLA INC. Multiple Inverters COVER SHEET PITCH: 270 (6:12) ARRAY PITCH:27° (6:12) NOTES: MP1 AZIMUTH: 109 ARRAY AZIMUTH: 109 MATERIAL: Comp Shingle STORY: 2 Stories ESS UNITS TO BE MOUNTED ON EXTERIOR WALL AND SHALL BE INSTALLED A MINIMUM PITCH: 270 (6:12) ARRAY PITCH:270 (6:12)OF 3' FROM ALL DOORS AND WINDOWS. LADDER ACCESS MP2 AZIMUTH:289 ARRAY AZIMUTH:289 FOR FIRE SETBACKS MATERIAL: Comp Shingle STORY: 2 Stories ESS UNITS SHALL MAINTAIN MINIMUM 10" OF SEPARATION BETWEEN EACH ESS UNIT PITCH: 200 (4:12) ARRAY PITCH:20° (4:12) MP4 AZIMUTH:289 ARRAY AZIMUTH:289 MATERIAL: Comp Shingle STORY: 2 Stories 3•S � �m PITCH: 370 (9:12) ARRAY PITCH:37° (9:12) "7pS MP5 AZIMUTH:203 ARRAY AZIMUTH:203 e MATERIAL: Comp Shingle STORY: 2 Stories sv \ PITCH: 370(9:12) ARRAY PITCH:37° (9:12) • MP6 AZIMUTH:23 ARRAY AZIMUTH:23 MATERIAL: Comp Shingle STORY: 2 Stories LEGEND E—STOP RSD rT 3'-10" FOR POWERWALL+ BACKUP SWITCH O (E) UTILITY METER & WARNING LABEL IN SOCKET Im INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS e� � Ac REur AUTOMATIC RELAY /, (E) LADDER ACCESS /� 3Ft D00R LEMFOR FlRE SETBACKS ' © DC DISCONNECT & WARNING LABELS WAY 1 J/ • AC Front Of F(/ / / , © AC DISCONNECT & WARNING LABELS ouse / // 0 DC JUNCTION/COMBINER BOX & LABELS sv ENERGY STORAGE SYSTEM FOR STAND ALONE OPERATION �¢ NE'A' �� DISTRIBUTION PANEL & LABELS KA^JJ J�'�' L / Lc LOAD CENTER & WARNING LABELS sv O DEDICATED PV SYSTEM METER 7. "' w w° 3"Fe Rso RAPID SHUTDOWN r - 3 FSB Q STANDOFF LOCATIONS LADDER ACCESS — CONDUIT RUN ON EXTERIOR FO P~ tnpe FOR FIRE SETBACKS CONDUIT RUN ON INTERIOR GATE/FENCE STRUCURAL0 -0D Q HEAT PRODUCING VENTS ARE RED (( ;( INTERIOR EQUIPMENT IS DASHED H U M P H R EY Digitally signed by �� HUMPHREY K KARIUKI K KARIUKI Date: 2022.05.12 SITE PLAN N 18:29:15 -0400' TOTAL ARRAY TOTAL ROOF AREA (SF): 3561 Scale:1/16" = 1' w E TOTAL ARRAY AREA IS p29-84 01' 16' 32' PERCENT OF TOTAL ROOF AEA CONFIDENTIAL— THE INFORMATION HEREIN [INVMTW BER JB-1192459 0 0 auTa�R DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Deniz Erkan 19.6 KW PV ARRAY Brian ParkBENEFIT OF ANYONE �" _ 5 L n ALL IT BE DISCLOSEDCN WHOLE OR N T TESLA INC, NOR 725 Terry Ln PARI TO OTHERS OUTSIDE THE RECIPIENTS V4 w Flashing-Insert Y 27 KWH ENERGY STORAGE SYSTEM ORGANIZATION, EXCEPT IN CONNECTION WITH : Southold, NY 11971 THE SALE AND USE OF THE RESPECTIVE esla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: PERMISSION of TESLA INC. le Inverters 1 425 785 2774 SITE PLAN 2 B 5/11/2022 Jobsite Specific Design Criteria Design Code ASCE 7-16 Risk Category II Table 1.5-1 Ultimate Wind Speed V—Ult 130 Fig. 1609A Exposure Category C Section 26.7 Ground Snow Load pg 30 Table 7-1 Edge Zone Width a 11.8 ft Fig. 30.3-2A to I MP Specific Design Information MP Name MP1 MP2 MP5 Roofing Comp Shingle Comp Shingle Comp Shingle Standoff ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w Flashing—Insert Flashing—Insert Flashing—Insert OF NEIN YD Pitch 27 27 37 -4 KAAI,l,q�'� SL/RLL: PV 14.9 14.9 11.4 y �? hA SL/RLL: Non—PV 20.8 20.8 20.8 01 s w ILU ��{t Standoff Spacing and Layout MP Name MP1 MP2 MP5 Landscape X—Spacing 72 72 72 SCRtiCNRAL 0 Landscape 24 24 24 X—Cantilever Landscape Y—Spacing 41 41 41 Landscape Y—Cantilever Portrait X—Spacing 32 32 32 Portrait X—Cantilever 15 15 15 Portrait Y—Spacing 74 74 74 Portrait Y—Cantilever — — — Layout Staggered Staggered Staggered X and Y are maximums that are always relative to the structure framing that supports the PV. X is across rafters and Y is along rafters. CONJB-1192459 00 C"ST°""� DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BEE USED FOR THE Deniz Erkan 19.6 KW PV ARRAY Brian Park T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSIEN: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 725 Terry Ln 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Southold, NY 11971 ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (49) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE- PERMISSION ATEPERMISSION OF TESLA INC. Multiple Inverters 425 785 2774 UPLIFT CALCULATIONS 4 B 5/11/2022 NOTES: ESS UNITS TO BE MOUNTED ON EXTERIOR WALL AND SHALL BE INSTALLED A MINIMUM OF 3' FROM ALL DOORS AND WINDOWS. ESS UNITS SHALL MAINTAIN MINIMUM 10" OF / SEPARATION BETWEEN EACH ESS UNIT r i•r of NEW Yo LCANJ4 r� A5'y fft N W 41111111111100 r 2 n � ,WEE UNI ST RAGE STRCTURALO r _550 C s sTF }rye I t PROPOSED POWERWALL LOCATION: r '''+'•..�,�,� EXTERIOR NORTH WALL ESS UNITS TO BE PLACED AT LEAST 3' AWAY FROM DOORS / WINDOWS `��►� ; SEE UL9540A DOCUMENT REGARDING SPACING BETWEEN UNITS CONFIDENTIAL- THE INFORMATION HEREIN ,pB NUMBER: JB-1192459 0 0 CUSTOMER- DESCRIPTION' DESIGN: CONTAINED SHALL NOT BE USED FOR THE Deniz Erkan 19.6 KW PV ARRAY Brian ParkBENERT Of ANYONE T = 5 L n SHALL IT BE DISCLOSEDCIN WHOLE OR N EPT TESLA INC,NOR MOUNTINGC mom` 725 Terry Ln PART TO OTHERS OUTSIDE THE RECIPIENTS ZS Com V4 w Flashing—insert Y 27 KWH ENERGY STORAGE SYSTEM ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES Southold, NY 11971 THE SALE AND USE OF THE RESPECTIVE (49) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN PACE NAME MEET: REV: DATE: INVERTER:PERMISSION OF TESLA INC. 425 785 2774 Multiple Inverters POWERWALL LOCATION 5 B 5/11/2022 MAIN PANEL SPECS GENERAL NOTES PRODUCT SPECS MODULE SPECS LICENSE Panel Number.NoMatch Inv 1: DC Ungrounded 1 — (1) Powerwall+ [24OV]#1850000—OD—C/PVI Assy. 1538000-25—F — (49)Tesla#T4DOH Meter Number:98357771 Inv 2: DC Ungrounded PV Module, 40OW, 371.5 PTC, 40MM, Black Frame, MC4/MC4—EVO2,ZEP, 1000V Underground Service Entrance 2 —(1)Powerwall+[24OV]#1850000—OD—C/PVT Assy. 153BOOD-35—F Voc: 45.3 Vpmax: 37.13 3 Psc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A MAIN SERVICE PANEL E-STOP E� 20OA/2P MAIN CIRCUIT BREAKER (N) 125A LOAD CENTER BUTTON POWERWALL+ 6 7 1 2%EG (E) WIRING W MP 1: 1x6 TESLA BACKUP SWITCH 13 AC DISCONNECT 1 ENERGY STORAGE X 9 z4ov DC+ I Z Y 0 DG MP 1: 1x7 1DOA 50A 2P ,zu DC+ _ ■ -- ---- ------------- �z DC+ i A DG+ N DG I $ DG G r ------------------------- - Ecc ---� Dc+ Dc+ MP 2: 2X8 13) r-------- ——J -1 N DG DG GND _— EGC ———— EGC I I 1 POWERWALL+ 1(1)Condult Kit; 3/4'EMT I I I ENERGY STORAGE 11 10 E I I N L2 L1 1 42P 1 u 4 IL2DC+ A DC+ TO 120/240V i Z I N DG g DC- SINGLE G SINGLE PHASE �c --- L------- ------------------------- - EGc --- Dc+ Dc+ MP UTILITY SERVICE : X I �——— � .� TN DG DG I GND —_ EGC ----- ---------'---- EGC I 200A 2P 1 1 (1)Conduit Kit; i'PVC.Sch.40 I (E) LOADS EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO 64 FEET TRENCH THROUGH SOFTSCAPE PHYSICAL DAMAGE WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLD BARE COPPER. (E) 200A DISTRIBUTION PANEL Up to (3) Powerwall+ units can be wired to the emergency stop button (e-stop) for rapid shutdown initiation. Low voltage Voc* = MAX VOC AT MIN TEMP wiring of connection(s) to additional units is not shown. GD Please see MCI wiring detail page for more information POI-(I)Gra d Ro A (2)Tesla 4J 4-STRING JUNCTION BOX 58g x 8, Copper AC UNFUSED, GROUNDED,Black, Diag DIN Rail with Bracket/Cord Grip DC Z (1)1624171—OD—G PV -(19)Tesla MCI,650V,12A Backup Switch RF(1)AWG(1)AWG#B, THWN-2, Blade —(I)AWG AWG�, THWN-2, White —(1)Eaton 204 MS68 O L-L(1)AWG#8, THWN-2, Red B—Une Meter Socket,200A, AW Hub top, Overhead, 4 jaws,Ring type 1-L(1)AWG#8, THWN-2, Green EGC Vmp =240 VAC Imp=32 AAC —(3)ILSCO/IPC 4/0-2/0 —(1 Conduit Kit 3/4' EMT Insula ion Piercing Connector,, Main 4/0-2, Tap 2/0-6 X 1 SQUARE D OM1224L125PR8 (1)AWG#8,THWN-2, Black —(1)AWG/8, THWN-2, White ( ) Load Center:125A,Converbble,NEMA3R,12sp/24Cir,120v/240v,10kAIC,Surface ® (1)AWG#8,iHWN-2 Red —(2)SOUARE D##H M250 (1)AWG#8,THWN-2, Green EGC Vmp =240 VAC Imp=32 AAC Breaker; 5DAp2P, 2 Spaces —(I Conduit Kit 3 4' EMT Y (1)CUTLER—HAMMER DS36FK (3)AWG#2/0,THWN-2, Black (1)AWC#B,THWN-2, Black Voc* =403.5 VDC Isc =22,28 ADC (2)PV W1r% AWG 10 Voc* =30Z62VDC Isc =11.14 ADC Class R Fuse Kit# (a6L(1)AWG#6,THWN-2, Green O (1)AWG#8,THWN-2, Red Vmp =297.04VDC Imp=21.54 ADC O�(1)AWG#6, Solid Bare Copper EGC Vmp =22Y.78VDC Imp=10.77 ADC — (2)FERRAZ SHAWMUT 0 TRIOOR ��(1)Copduit ,(1)AWG#1.0 tiM/THWN-2,,Green EGC—(1)ConduR Kif:,3/4'.EMT. ,, IJ Fuse; t00A.25OV.'Class RK5 2 PVC; Schedule 80 * _ ... .. . ... * _3 5 3 .. .1 1 ... —(1)CUTLER—HAMMER DG100NB (1 AWG#10,THWN-2, Black Voc —353.U6VDC Isc =11.14 ADC (2jPV Wire, AWG 10 Voc —353.06VDC Isc =11.14 ADC y Graund Neutral Kit; 6G-100A, General Duty(DG) (1)AWG#3,1HWN-2 Vfiite 6 (1)AWG#10,THWN-2 Red Vmp =259.91 VDC Imp=10.77 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =259.91 VDC Imp=10.77 ADC —(1)CUTLER—HAMMER #DG223NRB (1)AWG#3,THWN-2, Red (1 AWG#107 TIIHN/THWN-2, Green EGC• (1)Condgit Kit; 3/4'EMT Disconnect; 160A, 24OVac, Fusible, NEMA 3R "......"" " (1)AWG#3,THWN-2, Black 1 AWG 0,THWN-2, Black Voc* =302.62VDC Isc =11.14 ADC ( #1 (4)PV Wire, AWG 10 Vac =403.5 VDC Isc=11.14 ADC -(1 AWG#8,.NlkN-P,.Green,,.•, ,,••—(1)Conduit KI!;.171/ EMT O (1)AWG#10,1HWN-2 Red Vmp =222.78VDC Imp= ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =297.04VDC Imp=10.77 ADC W (I)UL 508 Emergency Stop Device— NEMA 4X (1)AWG#3,THWI-2, White (1 AWG#107 THHN/THNM-2, Green EGC•-0).Conduit•Kit;.3/4',EMT, ,..,.... � .................. .... ...... .......... .......... ®14�(1)AWG#3,THWN-2, Red (1 AWG A THWN-2, Blade Voc* =504.37VDC Isc =22.28 ADC '(4)FV Wire, AWG 10 Voc* =504.37VDC Isc —11.14 ADC IL..=LL(1)AWG#3,THWN-2, Black t �(1)AWG/8,THWN-2, Red Vmp =371.3 VDC Imp=21.54 ADC ® c'"� (1)AWG#fi, Sdid Bare Copper EGC Vmp =371.3 VDC Imp=10.77 ADC III�iF —111=t CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER: JB-1192459 00GUSTO ER: DESCRIPTION: DESGN. CONTAINED SHALL NOT BE USED FOR THE Deniz Erkan 19.6 KW PV ARRAY Brian Park T S L. n BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 725 Terry Ln 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MoiX�Es: Southold, N Y 11971 ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (49) Tesla # T400H TESLA PF TESLA INCT THE WRITTEN INTER: E- 785 2774 PAGE NAME- SHEET- DATE- PERMISSION O Multiple Inverters THREE LINE DIAGRAM 1 6 B 5/11/2022 0 PHOTOVOLTAICFli�VARNING: ,MNER I Label Location: Label Location: Label Location: (C)(CB)(JB) INV SOLAR .PV SYSTEM SolarEd a and,Delta M-Series and Telsa Inverter • • • ( ) EQUIPPED WITH RAPID Cg ' Per Code: EQUIPPED RAPID Per Code: Per ode: NEC 690.31.G.3 SHUTDOWN NEC 690.56.C.3 SHUTDOWN 690.56(C)(1)(a) Label Location: TURNM PHOTOVOLTAIC D (DC)(INV) ��'� 51ti1TCal40THE DISCONNECT Per Code: 'WPOSITIONTO pVPAt[EIS NEC 690.13.6 Label Location: sYS IrAMUCE CAUTION (POI) SHOiCKMAZARD DUAL POWER SOURCEPer Code: LNTHEARRAY. MAXIMUM VOLTAGE Label Location: SECOND SOURCE NEC 705.12.B.3 PHOTOVOLTAIC (DC)(INV) MAXIMUM CIRCUIT CURRENT Per Code: MAX RATED OUTPUT CURRENT NEC 690.53 OF THE CHARGE CONTROLLER Label Location: OR DC-TO-DC . (POI) (IF INSTALLED) WARNING INVERTER Per Code: OUTPUTCONNECTION NEC 705.12.B.2.3.b ■• NOT RELOCATE Label Location: THIS OVERCURRENT WARNING (DC)(INV) DEVICE Per Code: SHOCKELECTRIC IF A GROUND FAULT HAZARDINDICATED 690.41.B NORMALLY -• ■ ■ CONDUCTORS MAY BE Label Location: UNGROUNDED ANDENERGIZED] WARNING (DC) (INV) SHOCKELECTRIC THE DC CONDUCTORS OF PHOTOVOLTAIC Label Location: UNGROUNDEDAND PHOTOVOLTAIC ► (AC) (POI) MAY BE ENERGIZED • Per Code: NEC 690.13.6 SOLAR PV SYSTEM Label Location: ABB/Delta Solivia Inverter Label Location: EQUIPPED WITH RAPID Per Code: MAXIMUM AC = A (AC) (POI) SHUTDOWN 690.56(C)(1)(b) OPERATING CURRENT Per Code: TURNRAPID OPERATING VOLTAGEXIMUM AC NEC 690.54 SHUIDUMSYMCH Mt m io 1Ht•( P03MONTO SHUT ;------- IXMN wNUUcums OUrSIDETHEARRAY -- conDUCroRs WfM - I HE AHHAY HEU41N Label Location: ENERGUED IN SUNLIGHT WARNING (AC)(POI) (AC):AC Disconnect ELECTRIC _ Per Code: (C): Conduit SHOCKDO NOT TOUCH TERM • ■ NEC 690.13.B (CB): Combiner Box TERMINALSON BOTH LINE AND (D): Distribution Panel LOAD ■ ■ (DC): DC Disconnect IN THE OPEN POSITION (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection Label Set Label .•- LOAD CENTER CAUTION Per Code: TRI POWER SOURCEPer Code: NEC SECOND SOURCE IS PHOTOVOLTAIC S'ISTEM 1 4 NEC 1 THIRD SOURCE IS ENERGY STORAGE SYSTEM Label • • CAUTION DO NOT ADD NEW LOADSPer Code: .•- • • NEC 220WARNING Per ..- THIS EQUIPMENT FED BYNEC 705.12.B.2.3.c Label • • MULTIPLE SOURCES.TOTAL CAUTION R DEV to]OES, M101I DINWON UMAIN T THIS PANEL HAS SPLICED FEED- PerCode: SUPPLY OVERCURRENT DEVICE, THROUGH CONDUCTORS. NEC 312.8.A(3) SHALL NOT EXCEEDAMPACITY OF BUSBAR. LOCATION OF DISCONNECT AT ENERGY STORAGE BACKUP LOAD PANEL NOM{NAL ESS Label Label Location: VOLTAGE.= 12a240V CAUTION MAX AVAILABLE SNORT- Per ••- DUAL POWER SOURCEPer Code: CIRCUIT FROM ESS= 32APer 706.7(D) .•- • •- marked in field SECOND SOURCE ISNEC 705.12(B)(3) ARC FAULT CLEARING ENERGY STORAGE SYSTEM TIME FROM ESS: 67ms Label Location: DATE OF CALCULATION: ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHTPer •• Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALLPerCode: Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALLPer •• Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED INSIDEPerCode: AC Disconnect Backup Load Center TISSLn GENERAL NOTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 GD SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (69O.12.B.2.1) • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ J-BOX J-BOX J-BOX J-BOX J-BOX J- BOX MCI MCI DC- RETROEIT PV MODULES • MCIS ARE LOCATED AT ROOF LEVEL, JUST UNDER THE PV MODULES IN ACCORDANCE WITH 690.12 REQUIREMENTS 1 • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH — NUMBER OF MODULES BETWEEN MCI UNITS = 0-3 — MAXIMUM NUMBER OF MODULES PER MCI UNIT = 3 J-BOX J-BOX J-BOX J-BOX — MINIMUM NUMBER MCI UNITS = MODULE COUNT/3 MCI *Exception: Tesla (Longi) modules installed in locations where the max Voc for 3 modules at low design temperature exceeds 165V shall be limited to 2 modules between MCIs. PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR O WAN, PV Wire, 60OV, Black DC MORE INFORMATION T = 5 Ln GENERAL NOTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.B.2.1) GD • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ DIODE DIODE DIODE DIODE DIODE DIODE DIODE MG SOLAR ROOF TILES DC- 9 MCIS ARE LOCATED AT DECK LEVEL, JUST UNDER THE 1 DIODE DIODE DIODE DIODE DIODE DIODE DIODE MCI TILES IN ACCORDANCE WITH 690.12 REQUIREMENTS • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH — NUMBER OF TILES BETWEEN MCI UNITS = 0-10 DIODE DIODE DIODE DIODE DIODE DIODE DIODE — MAXIMUM NUMBER OF TILES PER MCI UNIT = 10 MCI — MINIMUM NUMBER MCI UNITS = TILE COUNT/10 DIODE DIODE DIODE DIODE PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR DC MORE INFORMATION 1 — (2)AWG, PV Wire, 600V, Black BACKUP SWITCH The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility / meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages,providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS 176 mm Model Number 1624171-xx- Continuous Load Rating 200A.120/240V Split phase Short Circuit Current Rating 22 kA with breaker' 4 Communication -- CAN — TOP Product Compatibility Powerwall 2 with Backup Gateway 2, I� Powerwal I+ Expected Service Life 21 years Li Warranty 10 years 'Breaker size must be equal to or greater than the available fault current. 205 mm COMPLIANCE INFORMATION Safety Standards USA:UL 414,UL 2735,UL 916 CA Prop 65 Emissions FCC,ICES ° ENVIRONMENTAL SPECIFICATIONS Operating Temperature -40°C to 500C(-40°F to 1220F) Storage Temperature -40°C to 850C(-40°F to 1850F) Enclosure Rating NEMA 3R Pollution Rating PD3 MECHANICAL SPECIFICATIONS Dimensions 176 mm x 205 mm x 74 mm (6.9inx8.1 inx2.9in) Weight 2.8 lbs Meter and Socket Compatibility ANSI Type 2S.ringless or ring type External Service Interface Contactor manual override' Reset button ----- ---- - ----- — -- 74 mm Conduit Compatibility 1/2-inch NPT Manually overrides the contactor position during a service event. T - S L in 2C`2-i'n-)2 TESLA.COM/EPIERGY t A,y -71 � POWERWALL+ PHOTOVOLTAIC (PV) AND BATTERY ENERGY MECHANICAL SPECIFICATIONS STORAGE SYSTEM (BESS) SPECIFICATIONS - - Dimensions 1596 x 755 x 160 mm(62.8 x 29.7 x 6.3 in) th Powerwall+Model Number 1850000-xx-y Total Weight 140 kg(310lb)' Solar Assembly Model Number 1538000-xx-y Battery Assembly 118 kg(261 Ib) Nominal Battery Energy 13.5 kWh Solar Assembly 22 kg(49 Ib) Nominal Grid Voltage(Input/Output) 120/24OVA C Mounting options Floor or wall mount Grid Voltage Range 211.2-264 VAC 755 mm 1,60 m�ml Frequency 60 Hz F - _ - Phase 240 VAC:2W+N+GND a ' Maximum Continuous Power On-Grid 7.6 kVA full sun/5.8 kVA no sun' -^ >. e: 9 Maximum Continuous Power Off-Grid 9.6 kW full sun/7 kW no sun' Peak Off-Grid Power(10 s) 22 kW full sun/10 kW no sun' Maximum Continuous Current On-Grid 32 A output TS S L f•9 Maximum Continuous Current Off-Grid 40 A output Load Start Capability 98-118 A LRA' _ T = 5 L Pi f PV Maximum Input Voltage 600 VDC 1596 mm I PV DC Input Voltage Range 60-550 VDC PV DC MPPT Voltage Range 60-480 VDC MPPTs 4 Input Connectors per MPPT 1-2-1-2 j Maximum Current per MPPT(Imp) 13 A3 Maximum Short Circuit 17 A3 jCurrent per MPPT(1,,) Allowable DC/AC Ratio 1-7 overcurrentProtectionDevice soAbreaker ENVIRONMENTAL SPECIFICATIONS Maximum Supply Fault Current 10 kA -20°C 50°C -4°F t 1220F)8 Output Output Power Factor Rating +/-0.9 to V - - -- ----------- Round - Operating Temperature to ( 0 1 - Trip Efficiency 9011.1 Recommended Temperature 0°C to 30°C(32°F to 86°F) Solar Generation CEC Efficiency 97.5%at 208 V Operating Humidity(RH) Up to 100%,condensing 98.0%at 240 V Storage Conditions -20°C to 30°C(-4°F to 86°F) - - -- -- - - -- - - - - - 95%RH,non-condensing Customer Interface Tesla Mobile App Up to g -- -------------- --- - --- - - ---------- State of Energy(SoE):25%initial P O W E R W A L L+ Internet Connectivity Wi-Fi,Ethernet,Cellular LTE/4G)^ -- -- -- -- -- - — Maximum Elevation 3000 m(9843 ft) PV AC Metering Revenue grade(+/-0.5%) --- ---- _--___-__--_______-___. Environment Indoor and outdoor rated Protections Integrated arc fault -- -- ---------- ._ - ------------- circuit interrupter(AFCI). Enclosure Type Type 3R Powerwall+ is an integrated solar battery system that stores energy from solar production. Powerwall+ has two ------"-------------- - ------ - - -- ------— ----- PV Rapid Shutdown Solar Assembly Ingress Rating IP55(Wiring Compartment) separate inverters, one for battery and one for solar, that are optimized to work together. Its integrated design and -- - - -- -- - - -- ------ - --------------------------------------------------------- streamlined installation allow for simple connection to any home, and improved surge power capability brings whole Warranty 10 years Battery Assembly Ingress Rating IP56(Wiring Compartment)-- - - - - - - - ---- IP67(Battery&Power Electronics) home backup in a smaller package. Smart system-controls enable owners to customize system behavior to suit their Noise Level @ 1 m <40 db(A)optimal, renewable energy needs. COMPLIANCE INFORMATION <50 db(A)maximum - -- - ------ — -----— -- - - ---- 'Values provided for 25°C(770F). PV Certifications UL 16996,UL 1741,UL 3741.UL 1741 SA,UL Load start capability may vary. KEY FEATURES 1998(US).IEEE 1547,IEEE 1547.1- Where the DC input current exceeds an MPPT rating,jumpers can be used to Battery Energy Storage UL 1642,UL 1741,UL 1741 PCS,UL 1741 SA,UL allow a single MPPT to intake additional DC current up to 26 A ITr/34 A I,. • Integrated battery, inverter, and system controller for a more compact install System Certifications 1973,UL 9540,IEEE 1547,IEEE 1547.1,UN 38.3 `Power factor rating at max real power. -' --_ 1AC to battery to AC,at beginning of life. • A suite of application modes, including self-powered, time-based control,and backup modes Grid Connection - - United States -- -- - - "Cellular connectivity subject to network service coverage and signal • Wi-Fi, Ethernet, and LTE connectivity with easy over-the-air updates Emissions FCC Part 15 Class B strength. ----- - -- 'The total weight does not include the Powerwall+bracket,which weighs an Environmental RoHS Directive 2011/65/EU additional 9 kg(20 lb). Seismic AC156,IEEE 693-2005(high) 'Performance may be de-rated at operating temperatures below 10°C(50°F) --- - ---_----_ - -- --- _ ---_-- -. __ -- ----- - or greater than 430C(109°F. NA 202_-05-06 � = ='+ �- � - iG�l-,��-;�� TESL.a.COIN/ENERGY SOLAR SHUTDOWN DEVICE SYSTEM LAYOUTS The Tesla Solar Shutdown Device is a Mid-Circuit Powerwall+with Backup Switch Installed Behind Utility Meter Interrupter(MCI)and is part of the PV system rapid shutdown (RSD)function in accordance with Article 690 of the applicable NEC.When paired with Powerwall+, solar array shutdown is initiated by pushing the System ° Shutdown Switch if one is present, Solar Backup Switch ELECTRICAL SPECIFICATIONSI p MECHAN CAL SPECIFICATIONS -- ---- --- ------ - ------------- ----- ----- - - Model Number MCI-1 Electrical Connections MC4 Connector Meter Nominal Input DC Current Rating(imp) 12 A T=s Housing Plastic _ Load center Meter socket panel Grid Maximum Input Short Circuit Current(I5C) 15 A Maximum System Voltage 600 V DC Dimensions 125 mm x 150 mm x 22 mm - - - Weight 350 g(0.77 Ib) RSD MODULE PERFORMANCE - --- - ---- - -- " -Mounting Options ZEP Home Run Clip - M4 Screw(#10) Maximum Number of Devices per String 5 M8 Bolt(5/16") Powerwall+ Backup loads Control Power Line Excitation Nail/Wood screw Passive State Normally open Maximum Power Consumption 7W Warranty 25 years Powerwall+with Backup Switch Installed Downstream of Utility Meter 250 mm r COMPLIANCE INFORMATION M4 Screw --- --f-- do-ns------------------------------------------- ----------- - (1�n)Cl Certifications UL 1741 PVRSE,UL 3741,PVRSA(Photovoltaic Rapid Solar Shutdown Array) 650 mm 150 mmM8 Bolt Backup Switch Utility Meter RSD Initiation Method External System Shutdown Switch Compatible Equipment See Compatibility Table belowTNail/Wood Screw ENVIRONMENTAL SPECIFICATIONS --" "" T=-SLR Load center Meter socket panel Meter socket panel Grid Ambient Temperature -401C to 50°C(-40°F to 122°F) - --- ------------ ----- - -- -- ------------------ Storage Temperature -30°C to 60°C(-22°F to 140°F) Enclosure Rating NEMA 4/IP65 r— 125 mm \__/ - - 22 mm Powerwall+ Backup loads UL 3741 PV HAZARD CONTROL (AND PVRSA) COMPATIBILITY Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with the Powerwall+and Solar Shutdown Devices.See the Powerwall+Installation Manual for detailed instructions and for guidance on installing Powerwall+and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesia Tesla TxxxS where xxx-405 to 450 W,increments of 5 1 Solar Shutdown Device per 3 modules" Tesla Tesla TxxxH(where xxx=395 to 415 W,increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules 'Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. -r = E L n )_r ,_�;__;;� TESLA.COM/ENERGY T c 5 I_ P, �t; _;_j -.�� TESLA.COM/ENERGY Powerwall+with Backup Gateway 2 for Whole Home Backup _� `/f47:7 Solar == I? - T Meter T 5 5 L n Load center Backup Gateway 2 Meter socket panel Grid Powerwall+ Backup loads Powerwall+with Backup Gateway 2 for Partial Home Backup ► / `�t��/ Solar YF� — n Y Meter T c 5 L n Backup panel Backup Gateway 2 Meter socket panel Grid l 1 �J Powerwall+ Backup loads -- Non-backup panel 1 15053 Non-essential loads 5 L_ r ,,,, ;�_;_�._�r;� TESLA.COM/ENERGY Tesla Photovoltaic Module Module Specifications T395H, T400H, and T405H Electrical Characteristics PowerClass T395 H T400H T405H The Tesla module is one of the most powerful residential photovoltaic Test Method--- STC NMOT STC 1, STC NMOT - -- modules available and exceeds industry engineering and quality standards. Max Power,P­(W) i395 296.3 400 300.1 405 303.8 Featuring our proprietary Zep Groove design,the all-black module mounts 21 Open Circuit Voltage.V.,(V) 45.27 42.69 45.30 42.72 45.34 42.76 close to your roof for a minimalist aesthetic.Modules are certified to IEC E; 8i Short Circuit Current,1­(A) 11.10 8.95 11,14 8.97 UL 61730-1,IEC UL 61730-2 and IEC 61215, 11.17 9.00 n"il.378 in Max Power Voltage,V­(V) 36.88 35.03 37.13 35.25 37,39 35.46 Max Power Current,1­(A) 10.71 8.46 1Q77 a.51 10.83 8.57 Module Efficiency(%) 20.1 20.4 -20.6 STC i 1000 W/rn,25'C,AM1.5 NOCT 800 W/ma,20°C,AM1.5,wind speed I m/s Mechanical Loading Temperature Rating(STC) Front Side Test Load 6120 Pa 1 128 lb/ft' Refer to module and system Temperature Coefficient of Isc +0.04%/'C installation manuals for Temperature Coefficient of V_ -0.27%/'C Rear Side Test Load 6120 Pa 1 128 lb/W allowable design loads,foot Front Side Design Load 4080 Pa 1 85lb/ft' spacings,and cantilever Temperature Coefficient of P­(W) -0.34Y, Rear Side Design Load 4080 Pa 1 85lb/ft2 specifications. Hail Test 35 mm at 27.2 m/s 1046 mm 1 41.2 in 40 0.5 mm T Mechanical Parameters -7 1 1.57 - 0.020 in I Cell Orientation 132(6x22) 'IF Junction Box IP68.3 diodes Cable 4mm2l_l2AWG,_1325mmj4Z2in.Length Connector Staubli MC4 Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass -7 Frame Black Anodized Aluminum Alloy Weight 23.5 k91 51.81 b 1Z 1890 mm x 1046 mm x 40 mm Dimension v M I E 74.4 in x 41.2 in x 1.57 in E Operation Parameters E E E E Operational Temperature -40°C up to+85°C 0 0 Power Output Tolerance -0/+SW Vo,&I,Tolerance +/-5% Max System Voltage DC 1000 V(I EC/UL) Max Series Fuse Rating 20 A NOCT 45.7+/-3'C ,IF IF Safety Class Class 11 IF Fire Rating UL 61730 Type 2 Linear Power Warranty Materials and Processing 25 years Extra Linear Power Output 25 years At least 98%of nominal power during first year.Thereafter max.0.5%degradation per t year.At least 93.5%of nominal power up to 10 years.At least 860%of nominal power up to 25 years. IV Curves Current vs.Voltage Power vs.Voltage Current vs.Voltage .7 12 r Coll Temp=25-C 450 Call T.-=-C 40 Wlmr a l000 w/m, 35 -Me ID ­11T­P=25•C 800 300 -800 W1.1 g -Ca­p=3M 600 250 -600 W., Q -C01 Te =45°C doo%V/,- 200 -400 yeS -COIT-55-C 2.o 2 -ca'-6vc I o -col-p- C 2 So 2 L a O 10 20 30 'o so 0 Io 20 30 40 50 o io 20 lo a0 so (v) 11h,(V) vat-(v) Tesla M.d,,],.Dat-h-t T = Ei L F, Tesla Module D.t-hoet T �- E. I­ rzi (TEPV-DS-0011-21) (TEPV-DS-0011-21) Q014PAp/ ROOFING SYSTEM SPECIFICATIONS �� GROUND ZEP LEVELING FOOT FA �� —1 F COMPP�� Listed to UL 2703 Listed to UL 2703 DESCRIPTION PV mounting solution for composition shingle roofs. Part#850-1511 Part#850-1397 Works with all Zep Compatible Modules. Auto bonding UL-listed hardware creates structural and electrical bond. I SPECIFICATIONS Designed for pitched roofs. Installs in portrait and landscape orientations. DC WIRE CLIP HOME RUN CLIP Engineered for spans up to 72"and cantilevers up to 24". Listed to UL 1565 Listed to UL 1565 Part#850-1509 Part#850-1510 ZS Comp has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2". 0 Attachment method UL listed to UL 2582 for Wind Driven Rain. \ ZS Comp supports 50 psf(2400 Pa)front and up to 72 psf(3450 Pa)rear side design load rating for Portrait module orientation per UL 2703. ZS Comp supports 50 psf(2400 Pa)front side and up to 72 psf(3450 Pa)rear side design ❑ ARRAY SKIRT F-1 END CAP load rating for Landscape module orientation. Listed to UL 2703 Listed to UL 2703 Engineered for compliance with ASCE 7-05,7-10,and 7-16 wind load requirements. Part 9850-1608 Part 9850-1586(Lett) g p q Part#850-1588(Right) Zep wire management products listed to UL 1565 for wire positioning devices. ZS Comp grounding products are listed to UL 2703 and UL 467. K 4 ZS Comp bonding products are listed to UL 2703. <I F1MOUNTING BLOCK F-1 FLASHING INSERT SKIRT GRIP INTERLOCK Listed to UL 2703 Listed to UL 2703 and UL 2582 for Wind Driven Rain Listed to UL 2703 Listed to UL 2703 Part#850.1633 Part#850-1628 Part#850-1606 Part#850-1613 Ab O O OP O l CAPTURED WASHER LAG HYBRID INTERLOCK Part#850-1631-002 and#850-1631-004 Listed to UL 2703 Part#850-1281 T - S L Tr ZS COMP DATASHEET 2 T = S L n ZS COMP DATASHEET 3 PV HAZARD CONTROL SYSTEM I ZS PVHCS PV HAZARD CONTROL SYSTEM PVHCS I CERTIFICATION UL 3741 REPORT DATE 10-20-21 (APPLICABLE TO ZS COMP, ZS SPAN, ZS RAMP, AND ZS SEAM) UL 3741 REPORT DATE 8-12-21 PV RAPID SHUTDOWN ARRAY, UL 1741 CATEGORY QIJR PV RAPID SHUTDOWN ARRAY, UL 1741 CATEGORY QIJR, REPORT DATE: 2021-06-11 (REV 8-10-21) WARNING:To reduce the risk of injury,read all instructions. WARNING:To reduce the risk of injury,read all instructions. PV HAZARD CONTROL EQUIPMENT AND COMPONENTS PV HAZARD CONTROL EQUIPMENT AND COMPONENTS Function Manufacturer Model No. Firmware Versions Certification Standard Firmware Versions and Checksums Function Manufacturer Model No. and Checksums Certification Standard PVRSE Mid Circuit Tesla MCI-1 N/A UL 1741 PVRSE PVRSE Mid Circuit MCI-1 Interrupter(MCI) Interrupter(MCI) Tesla 15503791 N/A UL 1741 PVRSE 7.6 kW:15380001 V4,CEA4F802 UL 1741,1998 7.6 kW:15380001 V4,CEA4F802 Inverter or Powerwall+ Tesla 3.8 kW:15340001 V4,FF76E4E1 UL 1741,1998 PVRSS/PVRSE Inverter or Powerwall+ Tesla 3.8 kW:15340001 V4,FF7BE4E1 7.6 kW:18500001 V4,CEA4F802 7.6 kW:18500001 V4,CEA4F802 PVRSS/PVRSE Hanwha/Q-CELLS Q.PEAK DUO BLK-G5/SC310-320 PV Module Tesla SR60T1,SR72T1 N/A UL 61730 PV Module Q.PEAK DUO BLN/A K G6+/SC330-345 UL 1703 SR72T2 Tesla Tesla TxxxS (xxx=405 to 450) UL 61730 Diode Harness Tesla SRDTH N/A UL 9703 Tesla TxxxH(xxx=395 to 415) (Not applicable to SR72T2) SR-BJ2X,SR-BJ3X, PVHCS Initiator Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC 690.12 PV Wire Jumper(s) Tesla SR-BJ4X,SR-BJMini N/A UL 9703N/A (PV Inverter) requirements. Pass-Through Box Tesla SRPTB-4 WA UL 1741 PVHCS Initiator Emergency stop device(NISD}Listed"Emergency Stop Button"or"Emergency Stop UL 508 or UL 60947 Parts PVHCS Initiator: Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC N/A (Powerwall+) Device"or"Emergency Stop Unit". 1,5-1 and 5-5 (PV Inverter) 690.12 requirements. Applies to variations of this part number with suffix of two numbers and one letter. PVHCS Initiator: Emergency stop device(NISD)-Listed"Emergency Stop Button"or"Emergency Stop UL 508 or UL 60947 (Powerwall+) Device"or"Emergency Stop Unit" Parts 1,5-1 and 5-5 Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual equipment and component 1 Applies to variations of this part number with suffix of two numbers and one letter. PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVHCS INSTALLATION REQUIREMENTS PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. Max System Voltage 600 VDC PVHCS INSTALLATION REQUIREMENTS PVHCS Maximum Circuit Voltage(Array Internal Voltage After Actuation) 165 VDC(cold weather open circuit) Max System Voltage 600 VDC Max Series-Connected Modules Between MCIs: PVHCS Maximum Circuit Voltage(Array Internal Voltage After Actuation) 165 VDC(cold weather open circuit) *Exception:Tesla S-Series(TxxxS)modules installed in locations where the max VOC for 3 3* modules at low design temperature exceeds 165V shall be limited to 2 modules between MCIs. Max Series-Connected Panels between MCIs 10 OTHER INSTALLATION INSTRUCTIONS OTHER INSTALLATION INSTRUCTIONS 1.An MCI must be connected to one end of each series string or mounting plane sub-array string. 1.An MCI must be connected to one end of each series string or mounting plane sub-array string. 2.Verification that MCIs are installed with 3 or fewer modules between MCIs shall be documented for inspection,by voltage 2.Verification that MCIs are installed with 10 or fewer modules between MCIs shall be documented for inspection,by voltage measurement logs and/or as-built string layout diagrams. measurement logs and/or as-built string layout diagrams. 3. For PV Inverter:The PVHCS initiator(AC breaker or switch)shall be sized and installed in accordance with NEC requirements. 3.For PV Inverter:The PVHCS initiator(AC breaker or switch)shall be sized and installed in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. The specific part shall be identified on the as-built system drawings. 4. For Powerwall+:The PVHCS emergency stop initiator shall have the following minimum ratings:Outdoor(Type 3R or higher), 12V, 4.For Powerwall+:The PVHCS emergency stop initiator shall have the following minimum ratings:Outdoor(Type 3R or higher), 12V, 1A,and shall be installed in accordance with NEC requirements.The specific part shall be identified on the as-built system drawings. 1A,and shall be installed in accordance with NEC requirements.The specific part shall be identified on the as-built system drawings. Refer to the Powerwall+installation manual for further details. Refer to the Powerwall+installation manual for further details. UL UL Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its ' Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its ® Certification and Follow-Up Service.The Certification Mark for these products includes the UL symbol,the words"CERTIFIED"and Certification and Follow-Up Service.The Certification Mark for these products includes the UL symbol,the words"CERTIFIED"and "SAFETY,"the geographic identifier(s),and a file number. "SAFETY,"the geographic identifier(s),and a file number. T = Ei L n TEZS-DS-0020-21 1 T S L n TESR-DS-0385-21 1 DATASHEET-M22-PVT K01-BVP 10.5 Protection against electric shock Does not apply,since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply,since the entire switchgear needs to be evaluated. avCIOEmergency stop/emergency switching off pushbutton,RMQ-Titan,1 NC, F=T* 10.7lntemal electrical circuits and connections Is the panel builders responsibility. blister pack Powering Business Worldwide' 10.8 Connections for external conductors Is the panel builders responsibility. , 10.9 Insulation properties Part no. M22-PVT K01-BVP Catalog No. 132624 10.9.2 Power-frequency electric strength Is the panel builders responsibility, Alternate Catalog M22-PVTKOI-BVPQ 10.9.3 Impulse withstand voltage Is the panel buldersresponsibility. No, 10.9.4 Testing of enclosures made of insulating material Is the panel bulders responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation.Eaton will Delivery program provide heat dissipation data for the devices. Product range RMQ-Titan 10.11 Short-circuit rating Is the panel builders responsibility.The specifications for the switchgear must be observed. Description Blister pack for hanging. Complete practical solution. 10.12 Electromagnetic compatibility Is the panel builders responsibility.The specifications for the switchgearmust be practical Can be ordered using a single article no. observed. Connection to SmartWire-DT no 10.13 Mechanical function The device meets the requirements,provided the information in the instruction leaflet(IL)is observed. Equipment supplied 1 Emergency-stop button M22-PVT ---- ---------- - - - - - - - -- -- - - - 1 mounting clamp M22-A Technical data ETIM 7.0 1 contact element M22-KOl Low-voltage industrial components(E600(1017)/Front element for mushroom push-button(EC001038) Electric engineering,automation,process control engineering/Low-voltage switch technology/Command and alarm device/Front element for mushroom push-button actuators Technical data -- -- --- - - - -- -------- - -- - (ecl®ss10.0.1-27-37-12-12[AKFO300141) General Colour button Red Ambient temperature Construction type lens Round Open °C -25-+70 Diameter cap mm 38 shipping classification DNV Holo diameter mm 225 GL LR Width opening mm ,0 Height opening mm 0 • • Degree of protection(IPI IP67 SqDegree of protection(NEMA) e • Type of button High Suitable for illumination No Switching function latching Yes TYPE APPROVED L-" Spring-return 'No = Germanischer Lloyd With front ring No Material front ring Plastic Design verification as per IMEEN 61439 Colour front ring Other Technical data for design verification Suitable for emergency stop Yes Rated operational currant for specified heat dissipation In A 6 Unlocking method Turn-release Heat dissipation per pole,current-dependent I'M W 0.11 Equipment heat dissipation,current-dependent Pvid W 0 Additional product information(links) Static heat dissipation,non-current-dependent Pa W 0 ILD4716005Z RMQ-Titan:Emergency stop buttons,Emergency stop buttons Heat dissipation capacity Pdies W 0 ILD4716005Z RMQ-Titan:Emergency stop https!/es-assets.eaton.com/DOCUMENTATION/AWA_INSTRUCTIONSALg4716005Z2020_01.pdf buttons,Emergency stop buttons Operating ambient temperature min. °C -25 _ I1II4716002Z RMQ•Titan System Operating ambient temperature max. °C 70 ILD4716007Z HMG-Titan System https.,//es-assets,eaton.com/DOCUMENTATION/AWA_INSTRUCTIONSAL04716002Z2020 09.pdf IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 102.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 1023.3 Verification of resistance of insulating materials to abnormal heat Meets the product standard's requirements. and fire due to internal electric effects 10.24 Resistance to ultra-violet(UV)radiation Please enquire 10.2.5 Lifting Does not apply,since the entire switchgear needs to be evaluated. 1026 Mechanical impact Does not apply,since the entire switchgear needs to he evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply,since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 04/01/2021 Eaton Industries GmbH 2/2 https//—.eaton,eu - - - - - "- - 032021 by Eaton Industries GmbH 04/01/2021 Eaton 132624 E02021 w7,0 EN 1/2 Eaton 132624 ED2021 V77.0 EN