HomeMy WebLinkAbout16937-zNo Z19567 FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT office of the Building Inspector Town Hall Southold, N.Y. CERTIPICATE OF OCCUPANCY THIS CERTIFIES that the building Location of Property 37300 House No. County Tax Map No. 1000 Section 85 Date DECEMBER 7~ 1990 ACCEBSORY ROUTE 25 CUTCHOGUE Street Hamlet Block 03 Lot 5.1 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 2, 1988 pursuant to which Building Permit No. i6937Z dated MAY 4, 1988 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is DETACHED BUSINESS ACCEBSORY BUILDING The certificate is issued to PHILIP G. HORTON (owner) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A N067869 APRIL 20, 1989 UNDERWRITERS CERTIFICATE NO. N067873 APRIL 20~ 1989 PLUMBERS CERTIFICATION DATED N/A 'Building Inspector ' / Rev. 1/81 ~0~ NO, ~ TOWN OF $OUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, N. Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) N~- 1693,7 Z at premises located at ...,,,.~..';~....~....O...;.--~ ....... ~,~...~.......~...~ ........................................................ ~oun~, To~ ~op ~o. ,000 ~ec,,on g..~ .......... B,oc~ .... ~ ............ Lot No ....... ....l .......... Building Inspector. Building Inspector Rev. 6/30/80 FORM NO. 6 TOWN OF SOUTHOLD Building Department Town Hall $outhold, N.Y. 11971 765- 1802 APPLICATION FOR CERTIFICATE OF OCCUPAN ,,, TOWN OF ~OUTHOt. D Instructions A. This application must be filled in typewriter OR ink, and submitted II to the Building Inspec- tor with the fol!owing;-for new buildings or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2.Final approval of Health Dept. of water supply and sewerage disposal-(S-9 form or equal). 3.App¥oval of electrical installation from Board of Fire Underwriters. 4. Commercial buildings, Industrial buildings, Multiple Residences and similar buildings and installa- tions, a certificate of Code compliance from the Architect or Eng neer respons b e for the bui ding. 5.Submit Plann ng Board approve of completed site plan requirements where applicable. B. For existing buildings (prior to April 1957), Non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of pz~perty showing all property lines, streets, buildings and unusual natural or topographic featu res. 2.Sworn statement of owner or previous owner as to use, occupancy and condition of bu ildings. 3. Date of any housing code or safety inspection of buildings or premises, or other pertinent informa- tion required to prepare a certificate. C. Fees: Additions $25.00 POOLS $25.00 ALTERATION $25.00 1. Certificate of occupancy New Dwelling.$25.O0, Accessory.,~$]0.O0 Business $50.00 2. Certificate of occupancy on pre-existing dwelling $ I00.00 3, Copy of certificate of occupancy $ 5.00, over .5 years $]0.00 ' 4.Vacant Land C.O. $ 20.00 5.Updated C,Oo $ 50,00 Date ,,Jb...C~. ..... q.l ......... NewConstruc tio~ ...... Old or Pre-existing Building Vacant Land Location of Property ~'? :~.~'J.d'? '. House No. Street ' Ham/et Owner or Owners of Property .... ~[\~iI.p ..... '~:...~.~-(~/~..~. 4~z~. .......................... County Tax Map No. 1000 Section ............ Block ............... Lot .... ~ ........ Subdivision ................................. Filed Map No ........... Lot No. Permit ?... Date of Permit . .^pplicant .... Health Dept. Approval ........................ ~abor Dept Approval ........................ Unde~riters Approval ...... ~.', ......... Planning Board Approval Request for ~emporary Certificate ..................... Final Certificate , .~ .................... Fee Submitted $ ........ ; ...............  and regulations. Construction on above described building a mit ets ~l~pp~icable Applicant..~ , V~:~ ~. /~. ~ ................ THE NEW YORK BOARD OF FIRE UNDERWRITERS 1085028 BUR~J~U OF ELECTmCITY -- 85 JOHN STREET, NEW YOR~ NEW YORK 10038 ~lS CE~IFIES T~T V~N~)UZKR, HAIN ROIU),~ POLKINYT601, P~;CONLC, N.Y. ~ ~ exami~ on [PR [ [~ 04 ~ ~ ~8 ~ and found lo be in com~ian~ with the requi~ments o~ th~ ~rd. 0 8 OTHER TWA C;~OCKS UNiT HIAIIS ~ S I R I C I OlCtN ~ $~;RV1CY, SOU'~'HOLD, NY, 11971 hire. #657 Z 11 rdm', to tJ~ oHic~ of H~ ~)orcl iY i.co~mcL r~spe~lors .~ COPY FOR BOIU:)lNG DEe~L~r~J~-HrT. THIS COPY OF CERTIFK:ATE UT NOT BI ~.~ERB I# ~R. :.~ THE NEW YORK BOARD OF FIRE UNDERWRITERS ~oo0.~7~ RUREAU o~ ",.ECTR,C.'Y '--- 35 JOHN STREET. NEW YORK. N~W YORK 10038 /)at, APICII, 20,198'~ ApplleationNo. on$11, 61375289/P, 9 N 067873 ~1~ CEglFIE$ THAT :HAR~,~S VM~DUZgR, MAIN ROAD, in t/~/e//ewinN/oeatlon; [] B~s~m~nt tee~eximi~on APR'~ [, 04, Pohgl~01, PKCONI¢, N.Y. [] ist Fi. [] 2nd FI. ,~,eetlon Block and /oufld to be in compliance with the requirements oy this ~4mrd. 9 LO 9 9 OVENS EXHAUST FANS R v I C E '~'.0. BOX 1268 SOIJTIiOI,!B, NY, ~t '197 mu~t rot b~ altered , monner; ~tum to trw office )UND,ATION (lst) )UNDATION ( 2nd ) )UGH FRAME & .PLUMBING SULATION PER N. Y. STATE ENERGY CODE FINAL ADDITION[L COMMENTS: INSPECTORS (516) 765-1802 VICTOR LESSARD, Principal CURTIS HORTON, Senior VINCENT R. W1ECZOREK, Ordinance ROBERT FISHER, Assistant Fire Building Inspectors THOMAS FISHER GARY FISH SCOTT L. HARRIS, Supervisor Sour. hold Town Hall P.O. Box 1179, 53095 Main Road Southold, New York 11971 Fax (516) 765-1823 Telephone (516) 765-1800 OFFICE OF BUILDING INSPECTOR TOWN OF SOUTHOLD November 28, 1990 Mr. Philip Horton: Arrowhead Lane Peconic, N.Y. 11958 Re: Building Permit ~16937-Z Premises: 37300 Route 25, Cutchogue, surf.Co. Tax Map ~1000-85-3-5.1 NoYo Dear Mr Horton: During a review of our files, it was noted that the above building permit has expired and a Certificate of Occupancy has never been issued. According to the Code of the Town of Southold Article XXVIII 100-2B1 and 100-284 a building permit is needed for any construction of additions, accessory structures, alterations or new dwellings, and it is unlawful to occupy or use said structure until the Certificate of Occupancy has been issued. Please contact this office as soon as possible so that we may clear up this matter. Thank you for your cooperation in this matter. Very truly yours, SOUTHOLD TOWN BUILDING DEPT. Victor Lessard, Principal Building Inspector VL:gar BOARD OF HEALTH ...... 3 SETS OF PLANS ....... 'FORM NO, 1 SURVEY ......... , TOWN OF SOUTHOLD CHECK .......... BUILDINGDSPARTMEN/ SEPTIC FORM ............. : /OWN HALL 8OUTHOLD, N.Y. 11971 ~ TEL.: 765-180:3 Examined. ~ .~. ......... , 19 ..CYi~ Approved ......... 19 Disapproved a/c ..................................... NOTIFY CALL ................ MAIL TO: (Building Inspector) APPLICATION FOR BUILDING PERMIT Date. S..--. ~ ......... , 19 .~.~. INSTRUCTIONS a. This app~icati~n must be c~mp~ete~y ~~~ed in by Wpewriter ~r in ink and submitted t~ the Bui~ding ~nspect~r~ with~3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property must be drawn on the diagram which is pa~ of this appli- cation. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of Occupancy shall have been granted by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolitig~ as herein described. The applicant agrees to comply with all applicable laws, ordinances, building coO, e, housing code,/an~l regulations, and to admit authorized inspectors on premises and in building for necessary in,st~FFc]ti;ns// /~/1 / ./ (Si=nature of applicant, or name,fi, f a corporation) .. .z9:c..... (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder. .......................... (as on the tax roll or latest deed) · If applicant is a corporation, signature of duly authorized officer. (Name an~ 't/tie of co~;r~i~ ~)~r)'. ....... ALL CONTRACTOR'S MUST BE SUFFOLK COUNT5' LICENSED Builder's License No .......................... Plnm~er's ~icense No.../U..C4~ .r..~ ........... ~ · Electrician s License No...~..~..~1'.~....~..~.~...~. /; Other Trade's License No ..... ~.' .... ~. ........ 1. Lo~ation ~ ..... of land on which proposed work will be done .................................................. · 5.q.'59..o. ............ ,...~.~. ?,.5 ...................... C~6.~.~ ................. House Number Street Hamlet County Tax Map No'. 1000 Section .... .~.-'. ) .......... Block ....~. ............. Lot.. o..( ............ Subdivision ..................................... Filed Map No ............... Lot ............... (Name) State existing use and occupancy of premises and intended use and occupancy of proposed construction: Existing use and occupancy b. Intended use and occupancy ............. 3. Nature of work (check which applicable): New Building ......... Addition, ~ ........ Alteration ...... Repair .............. Removal .............. Demolition .......... '... Other Work ............... 4. Estimated Cost ..~. '~.~..~...~. ................... Fee .5~....~.'.,~..,...~...~. (Description) · (to be! paid on filing this application) 5. If dwelling, number of dwelling units ............... Number of dwelling units on each floor ................ If garage number of cars i 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use ..................... 7. Dimensions of existing structures, if any: Front ............... Rear ............. Depth ............... Height ............... Number of Stories ........................... io It dditi '"' .......................... Dimens ns of same structure with aerations or a ons: Front ......... sRear ...... i ........... Depth ...................... Height ...................... Number of ~i~; .................. '-8. Dimensions of entire new construction: Front .......... . ..... Rear .............. Depth .......... ~.. Height ............... Number of Stories ................................................... 9. Size of lot: Front ...................... Rear ...................... iDepth .................... 10. Date of Purchase ............................. ,/~m__~e o/Former Owner 'i ......................... 11. Zone or use district in which premises are situated.. ~..' ' 12. Does proposed construction violate any zoning law, ordinance or regulation: .... ! ......................... .. 13. Will lot be regraded ............................ Will excess fill be removed from premises: Yes No 14. Name of Owner of premises .................... Address ............... i ....Phone No ................ Name of Architect ........................... Address ............... i ....Phone No ................ Name of Contractor .......................... Address ..... ' .......... i ....Phone No .............. 15. Is this property located within 300 feet of a tidal wetland? *YEs ..... No~.... *If yes, Southold Town Trustees Permit maybe required. PLOT DIAGRAM Locate clearly and distinctly all buildings, whether existing or proposed, and. indicate all set-back dimensions from property lines. Give street and block number or description according to deed, and sho~ street names and indicate whether interior or corner lot. STATE OF NEW YORK, COUNTY OF ............ ..... S.S ................................................. being duly sworn, deposes and (Name of individual signing contract) above nanled. says that he is the applicant He is the ............................................................... . .......................... (Contractor, agent, corporate officer, etc.) ~f said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this ~pplication; that all statements contained in this application are true to the best of his knowledge and belief; and that the ~vork w//l be performed in the manner set forth in the application filed therewith. ~worn to before me this ............. ........ day°f""N'°z ............. _ q°tary Public' ' '~' ' ~' ' '~)' ~-' ~' ' '~' 'I~t£1t & ~£ ......C°u nty ~//~'~'" '/~'~/" '/~/'~'..~.~. ~em Expir¢~ I~*rch ~0, MORTON BUILDINGS GENERAL SPECIFICATIONS LAMINATED COLUMNS - No. i or better southern yellow pine nell laminated 3 member S4S columns used in building are pressure treated below grade to a retention of .8 pounds per cubic foot with Chromated Coppe~ Arsenate Type III, Oxide type, as lib, ted in Federal Specification TT-W-571J. The treated portion of the column embedded in grounl shall be laminated with stainless steel nails. FOOTINGS AND ANCHORAGE - Column holes are dug 6 feet min. depth below grade and ready-mix concrete pads or dry concrete mix pads are poured in place (note plans f)r size & type). Two galvanized steel angle base anchors are placed 1" from bottom of column. ~dditional concrete mix is poured around base of column then backfilled with soil and compacted ab 8" intervals. ?LASHBOARDS - Splashboards are No. 2 ar better southern yello~ pine 2"×8" S2S and center matched, pressure treated to a net retention of .4 rounds per cubic foot with Chromated Copper Arsenate Type III, Oxide type, in accordance with American Wood PreservErs' Association Specification C2. ~One row is furnished for building on a level grade. FRAMING LUMBER - Side nailers are 2"xq" $4S SRF ~lOO MSR spaced approximately 30" O.C. with all joints staggered at attachment to columns. Roof purlins are 2"x4" S4S No. 2 SPF or better on edge spaced approximately 20" O,C. All other framing lumber i: standard grade or better. ROOF TRUSSES - Factory assembled with 18 or 20 gauge galvanizm steel truss plates as required and graded kiln dried lumber as specie, ed. In-plant quality control inJpection is conducted under the auspices of the Tgi inspection bureau. T~usses are ~esigned in accordance with current s~andards and specifications for the stated loading~ BRACING - 0.035"x1-1/4"'high tensile steel construction X-bracing in all unobstructed corners. Lateral truss ties and end bracing as needed. SIDING PANELS - 0.019" m~n., GgO zinc galvanized steel with an additional baked-on silicone finish. Color is i mil thick on exterior. ROOFING PANELS (PLASTISOL) - 0.019" min., GgO zinc galvanized steel. The top side of the panel shall have a baked-on plastisol coat with a minimum p?in~ thio!mess of 6 mils. TRIM - Die-formed trim of 0.019" mln., GgO galvanized steel on gables, ridges, corners, base, ~indows and doors with same paint finish as roofing and siding panels. GUTTERS - 5" box type gutters, color to match trim, on both si,les of the building. HEATING. PLUMBING~ VENTILATION~ AND ELECTRICAL WORK - By other~, not part of these plans. ,NOTE: BUILDING GENERAL SPECIFICATIONS apply unless indicated ~ifferently on specific job drawings or supplemental information. r335 PL 2/86 S H E E T I N'D E X SHEET DESCRIPTION / OF ~;SPECIFICATIONS ~ SHEET INDEX 2 OF .~ [ COLUMN PLAN c~ EL EW~T/ONS .~ OF 5SECTIONS & DETAIL 4 OF 5 CD~/DOP SECT/C~N$ RF~UIRED ~ 0CCUPAI%¥ 0R USE' IS UNLAWFUL W THOUT CERTiFiCATE OCCUPANCT DRAWN BY: ~/CHg~5 CHECKED BY: ~2~ DATE: DATE: DATE: CHUC/ SF/BEA'¥L A SS I hereby certify tllat thLs plan and specJficatLon was prepared by me or under my dLrect personal supervision and that I am a duly regLstered ProfessLona] Engineer and competent to prepare this document. DATE L~-~0-5~, REG. NO. L~Et]c¢ AP;~ROVED AS NOTED / 765-1802 9 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION . TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMRING 3. INSULATION 4. FINAL . CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS O~ THE N.Y. STATE CONST~UCTI©N & ENERGY J OFFICE R/VERH~XD ~ NY t, SCALE: /© O f~(~? ~ . SHEET NO,~ Lt O /~JQ£TH ( ~)THICK READI-MIX PAD OR ( 5 )50# BAGS SACKRETE PRE MIX W/WATER IN HOLE AND ALLOWED TO HARDEN. AND ( ~ )50# BAGS SACKRETE PRE MIX W/ WATER WHEN SETTING COLUMNS. ~j REVIfiED BY: I I gATE: PLASTISOL HI-RIB SIEEL · 2"x4" PURLINS (NO. ~ SPF) 2"x4" BEV. PURr FILLER STRIP 5" O,G, GUTTER-- 2"x6" BEV, FASCIA SR144 & SR146 FASCIA COVER--- PRECUT SOFPII 2"x6" OVERHANG NAILER -- (~) 1/2"x5-1/2" M. BOLTS & -- (4) 20d R,S. NAILS (~) ROWS 2"x4" NAILERS -- (2100f MSR SPF) TRUSS ~LO[~.~i ~,IINS. W/ 4 MIL VAPOR BARRIER --HI-RIi~ STEEL -- 2"x4" TOP BLOCK --2"x4" STRIPPING 6" B~TT INS, W/ 4 MIL VAPOR BARRIER GRADE TO HEEL HI-Ri B STEEL -- 3-2% 6" LAMINATED COLUMN SIDEV',IALL SECTION ~ P'PH WIND LOAD -- PROTECTIVE LINER ~ ,ASE TRIM & FILLER STRIP ) ~OW(S) 2"x8" SPLASHBOARD x4" NON-TREATED /2"x1" BLOCK & SR109 CONC. (BY OTHERS) BASE TRIM --PERIN~ETER INS. (BY OTHERS) -2"x6" TR. BOTTOM PLATE NOTE: CORNER AND EHDWALL COLUMNS TO MAVB 15" DIA. FTGS. W/ (1) 50~ BAG SACK~ETE OR ( 4")THICK ~BADI MIX PAD [N HOLE AND (1) §O#BAG SACKRETE WHEN SETTING COLUMNS I~ASE ANCHORS _ (T')THICK PEADI-MIX PAD OB ( ~ )50# BA(S SACKRETE PRE MIX W/WATER IN HOLI AND ALLOWED TO HAROEN. AND ( ~)501: BAGS SACKRETE PRE MIX W/ WATER WHEN IETTING COLUMNS. DRAWN BY: I ~,c.~ ~(~- ] DATE: CHECKED BY: DATE: REVISED BY: DATE: (~) 1/2"x ~"f' M, BOLLS (~) 2"xr." STUB COLUMN 2"X6" BLOCK PL ~C 2 ~ Fi~ SR2q/26 2"x3" JAMB (BEYOND) (3) 2"x6" JAMB COLUMN ( 2"x6" BLOCK (BEYOND] OHD %TECL ~'S.C. lRUSS HEADER HAILING SCHEDULE HEADER MEMBER STUB JAMB COLUMN COLUMN NOTES: 1. Numbers above are 2Od R.S. required per connection. 2. Pre-drill headers as re- quired to prevent splitting, 3. if number of nai]s required for header to jamb column conneotion is excessive to cause splitting, the excess nails may be insta~]ed in header support blocking, OHD. HEADER DETAIL c," ES~,TT bO5 OFFICE ,JOB NO. SCALE: SHEET NO. of HEADER NAILING SCHEDULE HEADER '~TUB JAMB MEMBER COLUMN COLUMN ~."~o" Pc Et NOTES: 1. Numbers ,tbove are 20d R.S. required per connection. 2. Pre-drill headers as re- quired to prevent splitting. 3. If Dumbe'- of nails required for header to jamb column connection is excessive to cause splitting, the excess nails mav be installed in header ~Jpport blocking, r-1 CHECKED BY: DATE: REVISED BY: DATE: SCALE: SHEET NO. ~ of ~- TRUSS SPACING 7L~'' O.C. LIVE LOAD .~0 PSF DEAD LOAD PSF CEILING LOAD ~ PSF TOTAL LOAD 37 PSF llx16 PL, NOTE: T.C, #i CA~,Z~3ER Al' CENTE~RL'rNE 16x10 PL, 18 GA, 7 11×13 WEB #2 I~ #3 -- 6x10 PL; L, C, 2×10 TRUSS DESIGN SPECIFICATION: Truss has been designed by computer using the Purdue Plane Structures Analyzer IAW current standards and specifications of recognized engineering principles. Ortput data will be provided upon request. LUMBIR SPECIFICATION (1982 NDS for Wood Construction): L~wer Chord -- 1950f - 1.5E MSR Southern Pine T(p Chord .... No. 1 K.D. - 15 Southern Pine W~,b Members -- No. i K.D. - 15 Southern Pine TRUSE PLATE SPECIFICATION (ICBO Evaluation Report No. 2929): ASTM A-q46, Grade A 20 Ga, and 18 Ga. where noted, galvanized steel Morton truss plates IdentlPied by a h~,xagon s~ampe~ every 1-1/4" along the center of the plate. I 1 '6,, 3X5 PL', EB #4 10'8" ~7' ~ o-~/2" CH ECKED~I!Y; DATE: REVISED Bf: I t DATE: WEBS ARE 2X4'S RAFTER LENGTH 18'5-1/8" LUMBER STRESSES TOP CHORD. LO~R CHORD NO. 1 1950 MSR rE~,# 5 12 3 13X8 '~L. 18 GA, PL, 18 GA, /2" 56~L COMMo SoCo TRUSS SHEET NO. r ,j SURVEY OF PROPER T Y A T PEOONIC. TOWN ,OF SOUTHOLD SUFFOLK COUNTY, NY, 1000- 85- 03- P/O 0..'5 Saale I"= 40' Jan. 21, 1988 CERTIFIE~ TO /~ _[~ ~ _~. ~ ~_~.~ LIC. ~ (~ HORTON -~~ ~N~N~ER~, MA~ ROAD ~ ~., SOUTHOLD, N.Y. 11971 87- 985 N0.4966~ P.C.