Loading...
HomeMy WebLinkAbout49475-Z .,suFFai, opo �oG Town of Southold -9/24/2023 P.O.Box 1179 o • T 53095 Main Rd y�j0l `1aoP ' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44593 Date: 9/24/2023 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 2200 Park Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 123.-8-10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/7/2023 pursuant to which Building Permit No. 49475 dated 7/14/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"alterations, including window and door replacements,to pre-existing single-family dwelling(front house)as qpplied for. The certificate is issued to JSK Park Ave LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEA TH APPROVAL ELECTRICAL CERTIFICATE NO. 49475 9/5/2023 PLUMBERS CERTIFICATION DATED • r yoi d ignature Y" TOWN OF SOUTHOLD ,,�SaFFei oo�° �ayri BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49475 Date: 7/14/2023 Permission is hereby granted to: JSK Park Ave LLC 159 W 24th St Apt 7B New York, NY 10011 To: legalize "as built" window and door replacements to pre-existing single-family dwelling (front house) as applied for. At premises located at: 2200 Park Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 123.-8-10 Pursuant to application dated 6/7/2023 and approved by the Building Inspector. To expire on 1/12/2025. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CO-ALTERATION TO DWELLING $50.00 Total: $450.00 Building for o��OF SO�r�ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 a� Jamesh ,southoldtownny.gov Southold,NY 11971-0959 'Q COMM BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: JSK Park Avenue LLC Address: 2200 Park Ave [ front roadside house] city:Mattituck st: New York zip: 11952 Building Permit#: 49475 Section: 123 Block: 8 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Homeowner Electrician: License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel 100 A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: Notes: AS BUILT SERVICE Inspector Signature: Date: September 5, 2023 2200 park ave frond road side 0F SoUTHp� qfq75 o2a00 Par k Al * # TOWN OF SOUTHOLD BUILDING DEPT. `ycourmN�' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] .FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE.VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: crrtA' At tKSP, Se r\j tGe up qr-aotf, g Ili opgo 40 -,Jsecurec� DATE g� `a3 INSPECTOR OF SO(/T,��� f TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] RO H PL13G. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Ila DATE INSPECTORt)q%m4-' :�� .� r �� .�, �,� �, , , ,� x° �'`,��� } �� � � ,, , 'sy �� �C` r �� � •; ��I � � .K '" ,. � i,F ��` � r ; .. s. .4 3 t• r rp,, ,@� .d, .a4!�, `a � .r ,.i °"� � g;.. +� � �,. � a fir. v"`"' m -�. � �({ L N ....� r R \ t. v' � �' y .� ., q .- �� � 6 a"°'" i �x �� *�''''� wr �_ ... ,_ ., .. ., .., M. _ � �: ....:.� ��ti ,� `." I �, .• �, , . _ .; ., ., �' -- �, . $r" -• w ,. �,� ... ���' !!��� �� z� w��� � � �y �� _ -m =�.�,a.�,a.�,,orrq �dl { �; :..:s, �. s r ♦ 5 J ' 1t. � �y r�i P 1• h •'�. , � 'fit�� J. ♦ �• 1 1 , . � .. ` SI 4 . ;ria 1 r h� t ... ....mss ) t 4 a : y ; ✓ f �r mow. )}cr t { � t 1 , .i f . -_ -rs'* n.>•.�rx,�syrr�°C`-� �. .<.,r.: _..rr„-, j,. ;...;.,,y„� ,....f- _;«. �.r^ . .^'.r+ �+R+v^,':'Y.w.ry*""'� hMF6X`..�,. "�.. � a r � 3 k � y� 7 i`. d k Y• � t }} 1 o s S S •i �z a •Sw" Y ya�. �� .•ins•- ., . " 'rs ' r �► FIE,LD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) -------------------------------------- FOUNDATION -----------------------------------FOUNDATION (2ND) ung z � o 9� C y ROUGH FRAMING& � PLUMBINGroo �H � 1 1 INSULATION PER N. Y. STATE ENERGY CODE — Zo FINAL ADDITIONAL COMMENT f1� Z rn N � N O t� � d t� b H �su4wckoo� TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 • �aa�� Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only I )j ;»;'(�? ,I 11 PERMIT NO. Building Inspector: JUN — 7 2023 Applications and forms must be filled out in their entirety.Incomplete, applications.will not be accepted. Where the Applicant is not the owner,an• ;'_ - ,, Owner's AUthoiriiatiOn form(Page 2)'shall be completed.' Date:6/5/2023 OWNER(S)OF PROPERTY: Name:JSK PARK AVENUE LLC SCTM# 1000-123._8-10 Project Address:2200 PARK AVENUE, MATTITUCK, NY 11952 (FRONT ROADSIDE HOUSE) Phone#:917-520-9967 Email:SKIM_YTD97@HOTMAIL.COM;JSIREFMAN@SIREFMANVENTURES.COM Mailing Address: 150 HICKS STREET #4A, BROOKLYN, NY 11201 CONTACT PERSON: `. Name: MARTIN D. FINNEGAN_(FINNEGAN_LAW,_P.C.) Mailing Address:PO.BOX. 1452, 13250. MAIN R, OAD,_,MATTITUCK.,. NY 11952 .V. Phone#:631-315-6070 Email:MFINNEGAN@ NORTHFORK.LAW .DESIGN PROFESSIONAL INFORMATION: Name:TBD Mailing Address: ----------------- Phone#: Email: CONTRACTOR INFORMATION:'., Name:TBD Mailing Address: Phone#: Email: ."DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: F21 Other AS-BUILT WINDOWS&DOORS $N/A Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION' Existing use of property: R ES I D ENTIAL Intended Use of property: RESIDENTIAL Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? ❑Yes ANo IF YES, PROVIDE A COPY. B Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of.the Town Code."APPLICATION IS,HEREBY MADE to,the Building Depariment•for'the issuance of a Building.Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions;alterations or for removal or demolition'as herein described.The applicant agrees to comply wiih all applicable laws;ordinances,,building code, " housing code and regulations and to admit authorized inspectors on premises and in'building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor-pursuant to Section 210.45 of.the New York State Penal Law. , Application Submitted By(print name):MARTI N D. FI N N EGAN BAuthorized Agent ❑Owner Signature of Applicant: Date: 6/5/2023 STATE OF NEW YORK) SS: COUNTY OF SUFFOLK ) MARTIN D. FINN EGAN being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the AG ENT (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this dayof JUNE 2023 Notary Public SCHWEITZER ANNALISE PROPERTY OWNER AUTHORIZATIONNOTARY PUBLIC-STATE OF NEW YORK NO.01 SC6409457 (Where the applicant is not the owner) QUALIFIED IN SUFFOLK COUNTY MY COMMISSION EXPIRES SEP 28,20 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) SARAH KIM, SOLE MEMBER OF I, JSK PARK AVENUE LLC residing at 159 WEST 24TH STREET, APT. 713, (Print property owner's name) (Mailing Address) NEW YORK, NY 10011 do hereby authorize MARTIN D. FINNEGAN (Agent) to apply on my behalf to the Southold Building Department. IZo 73 wner's Signature) (Date) JSK PARK AVENUE LLC BY: SARAH KIM, SOLE MEMBER (Print Owner's Name) guEFQt,�`, BUILDING DEPARTMENT- Electrical Inspector �Z4 OGS TOWN OF SOUTHOLD C* Town Hall Annex - 54375 Main Road - PO Box 1179 CA Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(aD-southoldtownny.gov — sea nd(D-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 6/7/2023 Company Name: HOMEOWNER Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: JSK PARK AVENUE LLC Address: 2200 PARK AVENUE, MATTITUCK, NY 11952 (FRONT ROADSIDE HOUSE) Cross Street: MARRATOOKA ROAD Phone No.: 917-520-9967 -JOSHUA SIREFMAN Bldg.Permit#: email: MFINNEGAN@NORTH FORK.LAW Tax Map District: 1000 Section: 123.00 Block: 08.00 Lot: 010.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): UPGRADED ELECTRICAL SERVICE AND PANEL WITH ROMEX WIRING. Square Footage: Circle All That Apply: Is job ready for inspection?: F✓ YES ❑ NO —]Rough In 57 Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 H Frame Pole Work done on Service? 0 Y N Additional Information: PAYMENT DUE WITH APPLICATION � L �gUFFAtIr BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD C= Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ' ro.gerrC@,southoldtownny.gov - seand(cDsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 6/7/2023 Company Name: HOMEOWNER Electrician's Name: \ License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: JSK PARK AVENUE LLC Address: 2200 PARK AVENUE, MATTITUCK, NY 11952 (FRONT ROADSIDE HOUSE) Cross Street: MARRATOOKA ROAD Phone No.: 917-520-9967 -JOSHUA SIREFMAN Bldg.Permit#: email: MFINNEGAN@NORTHFORK.LAW Tax Map District: 1000 Section: 123.00 Block: 08.00 Lot: 010.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): UPGRADED ELECTRICAL SERVICE AND PANEL WITH ROMEX WIRING. Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO []Rough In Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground LateralsF-] 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION �� PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments S.C.T.M.# DISTRICT 1000 SECTION 123 BLOCK 8 LOT 9 & 10 � Je U.P./ ID ti AK W.V. �� \ U.P. 4D d 10 DAK • qJ \ `fi, JEt1•E� 10"Locu zo•C. 2 12" K OA '\ 10'' 62 asQ`qh 4 \ 4 99 yh \\o \\ 1 STY FRAME.. ;; ':D LU . SI FRAME"'w' \ 9,c\ CONC. 0rDWELLING.' \ dr PATIO U.P. EXISTING LOT COVERAGE O `FFL=21.6.; \ \ ? AREA LANDWARD OF CREST OF BANK:27669 S.F.orO.64 ACRES #2150.. \ `q, '. DWELUNG(NORTH):1081 S.F. £o SHED:76 S.F. DWELLING(SOUTH):1684 S.F. I \qy I � TOTAL:2841 S.F.or 10.2% yF PATIO ASPHALT c^ "5 / DRIVEWAY 1e� 113 / 4 v i / \I a"oAK 1B EXISTING L07 COVERAGE \ eq \ e dzz oAK AREA LANDWARD OF CRESiOF BANK:27495 S.F.ar0.63 ACRES mFp \� s'QaK OWELLING(NORTH):1081 S.F. op \ 4 q' do•oAI�"Qac SHED:16 S.F. Am \\ Q e' DWELLING(SOUFH):1684 S.F. z 6.OAK t.s'w TOTAL:2841 S.F.or 10.3% a 14•aa4 e>� c Kc OAK E° 20. QOA �� t. 10"OAK 7 fiq ,6 19 S.C.T.M.#1000-123-8-11.3 I... 'w i LAND N/F OF `q1 1� IOAK I 10"OAK P.79 I 1 oAK CNC PARK AVENUE LLC 9 64 + 6o?K 20'OAK I OAK 9\ fi N 6.OAK 1 I6"OAK 6"0 o �yI N @'j, 1 c'o 10.OAK 0"OAK t^?, DWELLINGS s oa 1 i s W d6"OAK Q h W/PUBLIC WATER t.7' 1 14 OAK Cn 1h 6.OAK \ y Ob a 150' �O 5`{ \fit' \\I6"OAK 6 OAK 2.7' 14.OAK T 2. � as \:✓ \1 DAK , 22.OAK S.C.T.M.#1000-123-8-8.3 �j�c�< u.P. '' LAND N/F OF OH. 9 TIMOTHY MURRAY 16"Q — P ASPHALT DWELLINGS m \ DRIVEWAY W/PUBLIC WATER 2.9•E ,6 150' 12,OAK \ 10• O 14"OAA�K^^'�+� MON. q 1'q'W /^{ l 10.OeK 10'AK 14.OAK \;J 'ib 12"O o i6"o pD % wi 16'OAK 10 0 K 8.OAK \10-?O�AK 11.4 m f •6J SHOWER b 10\p 10'OAKq. FENCE f ELEV. 18.2 ::m SM BROWN ...:' 1fib �fi' SILTY SAND 5.0' � PALE BROWN '0 ::::i.t➢ �:.''.:. FINE SP SAND ...... fig 224' 31.2' WATER IN _``"' ' 4D PALE ROOK w� \ SP BROWN `t0 pIo ZONE X FINE 3 28' - �y9 SAND11 h 18 2J' 2,29' APRIL 15, GEO Mc00NALD GEOSCIENCE /9 e O� ,gG' S 0 Z�' ZONE BOUNDNit FLOOD I25 FEMA MAP#36103CO482H AREA:59,791.66 SQ-FT. Or 1.37 ACRES ELEVATION DATUM. _ NAVD88 ____ ___ / / W z Z1'a2 W ZONE VE(EL 8) UNAUTHORIZED ALTERATION OR ADDITION TO HIS SURVEY IS A WOLA77ON OF 5EC77ON 7209 OF HE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY 'j S j0503a Fy0NG MN ONL YMAP NTo THEROT BEAEON, LAND SURVEYORS WHOM THE SURVEY ISPREPARED AND ON HIS BEHALFTO HE 7771E COMPANY,, SED SEAL SHALL NOT BE ERED TO BE A VALID UE COPY GUARANTEES GOVERNMENTAL AGENCY ANDATED LEADINGREON SHALL INS71TU170NRUN / tlE\INES 0 LISTED HEREON,AND TO HE ASSIGNEES OF HE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE MHW EQUALS TIDAL WEIIANO BOUNDARY HE OFFSETS OR DIMENSIONS SHOWN HEREON FROM TH PROPERTY L/NES TO HE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE HEREFORE THEY ARE AS DETFRNINED BY NOT INTENDED TO MONUMENT HE PROPERTY LINES OR TO GUIDE HE ERECTION OF FENCES,ADD177ONAL STRUCTURES OR AND OTHER IMPROVEMENTS. EASEMENTS EN-CONSULTANTS 11-09-22 AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT HE 77ME OF SURVEY SURVEY OF:DESCRIBED PROPERTY of NEW CERTIFIED TO: JSK PARK AVE, LLC; MAP OF: A,P' SH M N'orYo,P o, 4 FILED: �� SITUATED AT:MATTITUCK F 0 TOWN OF:SOUTHOLD o� SUFFOLK COUNTY, NEW YORK KENNETH M WOYCHUK LAND SURVEYING, PLLC 2d, osos82 5JQ- Professional Land Surveying and Design THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL P.O. Box 153 Aquebogue, New York 11931 LOCATIONS SHOWN ARE FROM FIELD OBSERVA77ONS FILE#22.2-1 13 SCALE:1"-30' DATE:AUG. 30, 2022 N.Y.S. LISC. NO. 050882 PHONE(631)298-1588 FAX(631)298-1588 AND OR DATA OBTAINED FROM OTHERS. ,r Ande rsen t 0o a S. D R a. ..D,o w H_I n: e tl P.a. i o-_Doo s,.=-;,;>l.n.sw:i:�:.. W1 N ®, i r. Contents Hinged Patio Doors- Inswing ` Basic Unit Details 26-2 Options/Accessories Accessibility Option.............................................`...26-5 r Andersen® Grilles....................................................26-6 Extension Jambs 26-7 -- - 8Anc Anchoring Methods.......................................................26 Joining Details 26-9 Suggested Product Applications 26-10 • 20/10 year limited warranty,fully transferable, non-prorated. • Choose Low-E tempered or Low-E Sun tempered COMPLY WITH ALL CODES OF glass. Dual-pane tempered insulating glass is also NEW YORK STATE & TOWN CODES available. AS REQUIRED AND CONDITIONS OF • Smooth,easy operation. „ -n • Choose White,Sandtone orTerratone° color SOtft TOWN PLANNI G BOARD exteriors. • White interiors can be painted to match home's SDJIhO TRUSTEES decor. A P P9 OVED AS NOTED DATE: 3B.P.# (� FEE:. BY: NOT IF ,BUILDING DEPARTMENT AT :�1�rf-1iV -. \.r i U FOLLOW8 AMG.IN0 T4 PM IONS;FOR THE 'E IS UNLAWFUL 1. FOUNDATION - TWO REQUIREDATHOUT'CE:FT1FiCAT FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING r='pCUNC 3. INSULATION 4. FINAL = CONSTRUCTION MUST BE COMPLETE F :'P C.O. ALL CONSTRUCT!"'N SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. REV. 12/O6 ARCH ITECTU RAL D E T A I L F I L E 26-1 `~ u. Anders'en : T V ' Tilt-Wash Double-Hung Windows ' Basic Unit Details Tilt-Wash Double-Hung Windows for 4-1/2^Wall...............................................19'2 Basic Unit Details � Picture,�anuomandCh � oo "mVV|nUnwo�t E�enuonJambu------'1�3 Basic Unit Details' Tilt-Wash Double-Hung Windows with Drywall Rotum-------------'10-4 ` Basic Unit Details- R�ue\�anuomand Ondo�"mWindows with DqwaUR�um--------.19it � Options Accessories Andn�oo~GhUou-----------------------------19'0 Extension Jambs h>rllk-VVanhDouble-Hung Windows.....................10'7 Stool Applications..........................................................................19-7 ' 2U/10year limited warranty,fully transferable, Extension Jambs for Picture,Transom and Circle TUTmWindows......10'8 non-prorated Trim Options and Applications ' ' Eordual pane insulating glass Plinth Blocks for Circle To 'mWindows.............................................. A'Q ' White ornandtonovinyl clad low-maintenance Interior Casing for Circle nmTmWindows.........................................10'10 exteriors ` Joining Details for 4-1/2"Wall ........................................................................10'11 Narrow profiles for larger glass area ' Joining D�ai��t DgomaUR�om----------------------1Q'12 ' Anin'm�shba�nnmtnminim�oth��mwof the jamb liner Anchoring Methods.........................................................................................10'13 ' Clear pine nroptional omfninhodwhko Suggested Product Applications......................................................................1Q'14 interior ' Innovative sizing format tosimplify ordering and installation - � ` ' xcv0,/on A R C H | T E C T U R A L D E T A | L F | L E 19-1 Andersen® WINDows • o,00RS ® ,,Hinged Patio Doors - Inswing Contents Hinged Patio Doors- Inswing Basic Unit Details 26-2 Options/Accessories Accessibility Option................................................26-5 Andersen®Grilles....................................................26-6 Extension Jambs....................................................26-7 ,r Anchorin Methods 26-8� g JoiningDetails..............................................................26-9 �. Suggested Product Applications..................................26-10 • 20/10 year limited warranty,fully transferable, non-prorated. • Choose Low-E tempered or Low-E Sun tempered glass. Dual-pane tempered insulating glass is also available. • Smooth,easy operation. • Choose White,Sandtone orTerratone° color exteriors. • White interiors can be painted to match home's decor. REV. 12/06 A R C H I T E C T U R A L D E T A I L F I L E 26-1 Basic Unit Details - Single and Two Panel Basic Unit Scale 3" = 1'-0" (1:4) 1-5/16'(3 1 3) 4-9/16"(116) 1-5/16"(3 3) 4-9/16"(116) 3/4"(19) �- 7 5-5/8"+(143+) x 5-5/8"+(143+) depending on depending on hinge adjustment hinge adjustment PW- W L L Head '0 Head n m n c no o c o E o o E o E a° E E = y E = O Andersen' Andersen® optional optional gliding 10-3/8"+(264+) hinged 10-3/8"+(264+) insect screen depending on insect screen depending on 1 hinge adjustment hinge adjustment 1/4"(6) '. 1/4"(6) a1-1/4' 18) L� a 1-1/4"(318) SIII SIII 6"(152) 6"(152) Vertical Section - with Gliding Insect Screen Vertical Section - with Hinged Insect Screen Two Panel - Active/Stationary or Stationary/Active Single Panel - Active Two Panel - Active/Stationary or Stationary/Active 26-2 ARCH ITECTU R A L D E T A I L F I L E REV. 12/06 ;'.N��'z° .i „hay: .�' „#.. ��xui;:' +;t.,a.` ..�, ,. ��',, i.�,¢• ,�, q u�^^ e�^,;.y� A �7 ;,W�GN9D OMS •.D�O.ORrS �H�I„n g+e(I' R�a�t�i�o��p.D�o o r s -”I�n3s�.w:(nrjf�_ _ , ,.��# a-z -a. _- <.4'�-.,..�— v .s•..r, .,its O�ep.�F�'%«;,'ei: o .>Y.,t�4.'. F" �+irr,,. l" d'�".yi Basic Unit Details - Single and Two Panel Basic Unit Scale 3" = 1'-0" (1:4) Metro,Collection Tribeca°handle hardware Dual-pane insulating tempered glass 5-5/8"(143) 5-5/8"(143) 3/4"(19) 3/4"(19) w2 4 Optional Andersen® "q hinged insect screen Jamb Jamb Clear Opening Width 1-1/4" (318) (318) Unit Dimension Width 3/8"(30) 3/8'-(10) Minimum Rough Opening Width Horizontal Section - with Hinged Insect Screen Single Panel Active Stationary Panel Active Panel 5-5/8"(143) 5-1/8"(130) 5-1/8"(130) 5-5/8"(143) 3/4"(19) 3/4"(19) I „t,c .off vkl .r Astragal Jamb fb Jamb 50=2'5-5/8"(752) 50=2'5-5/8"(752) 54-2'7-5/8"(803) 54=2'7-5/8"(803) 60-2'11-5/8"(905) 60—2'11-5/8"(905) Unit Dimension Width 3/8"(10) 3/8"(10) Minimum Rough Opening Width Horizontal Section - with Gliding Insect Screen Two Panel - Stationary/Active (shown) or Active/Stationary REV. 12/06 A R C H I T E C T U R A L D E T A I L F I L E 26-3 ;�, ,�,'C�^.�•, .s ,se.;. aa r„. ,'13:': ..s.,�;•o c 4 ".„,?`',"'T, ,.r. 3 ;�' y ,. �s .y. wxi Nno was • D 0" O+R S .-I n.Tg ead_ P anti o �D o.o�r,;s •* F g° x `y °' p' Basic Unit Details - Single and Two Panel Basic Unit Scale 3” = 1'-0" (1:4) Door at 90°clear opening position 4 Door at fullclear openingposition 'kyEi•. I Jamb Astragal Jamb Clear Opening Width at 90° Clear Opening Width Full Open Position 50=2'5-5/8"(752) 50=2'5-5/8"(752) 54=2'7-5/8"(803) 54=2'7-5/8"(803) 60 a 2'11-5/8"(905) 60 m 2'11-5/8"(905) Unit Dimension Width Horizontal Section Stationary / Active 26-4 ARCH I T E CTU RAL D E T A I L F I L E REV.12/06 ;�W i N-D.0 4Y S • oho.IRs. ® 1-1 i n gpe d. P a t�:i�o: ,Dxo o r's� - I,n s wdi n g _ ;� �� ';� Basic Unit Details - Stationary Panel Basic Unit Scale 3" = 1'-0" (1:4) 1-5/16"(33) 3/4"(19) 5-5/8"(143) 5-5/8"(143) 5-5/8"(143) m d E x d c n o Head m n, 'o E ¢ o -- I ----- -- - E Jamb Jamb 10-3/8-1(264) 1-1/4" 1-1/4" (318) Unit Dimension Width (318) Minimum Rough Opening Width Horizontal Section Stationary Panel — 0 1_1/4 T(318> sill 6"(152) Vertical Section Stationary Panel Accessibility Option Scale 3" = V-0" (1:4) Accessible Door A special"accessible door"option is available that offers a 32"clear opening Low threshold sill width at 900 and a 1/2"high threshold. Meets door width and threshold height requirements of ICC/ANSI A-117.1-2003 and ADAAG guidelines.Contact your Fa lid Andersen supplier for availability. 1/2"(13) REV. 12/06 A R C H I T E C T U R A L D E T A I L F I L E 26-5 J,N" • Standard Grille Options Accessories Contact an Andersen Representative for project specific grille options. 200 Series Grille Options Removable Interior Andersen®Finelightm Grilles Grilles-Between-the-Glass Grille Profiles Scale - Full Removable Interior Wood Grille Profiles(chamfer profile). T-- T-- T-- C�� 16" 16" 16' 7/1-- 7/1-ff7/-L- 1 3/4" 7/8" I 1-1/8" Andersen®Fin'elightm Grilles-Between-the-Glass 1/2' 3/4" Window Profile Patio Door Profile 26-6 ARCH I T E C T U RAL D E T A I L F I L E R E V.12 0 6 i�� �'\"/�rysen® • -9'� �Y�&'d ��C ^k� .>ra"�i'a'� '�'§�^�k��!� ,�Y' �• .5. �yp.�1p' y�y{ :y� .-� A+.. '�'. yaA� Kr -�w�,ir,iv:D�o)W.S.•.3D.;O,;o`,R�s ® H,i:n�j:e�tl':;�P'a`�f�l;o- D'o oar S Options Accessories Prefinished White Interior Extension Jambs Scale 3" — V-0" (1:4) 11/16"(17) ----------------- 1. 77 ------------ CP (4 LL 7-1/8"(181) 6-9/16"(167) 5-1/4"(133) ��l�d Extension jamb Extension jamb Extension jamb = 4-9/16"(116) Interior extension jambs have a low-maintenance white finish 1-5/16'(33) and are available for 5-1/4"(133),6-9/16"(167),and 7-1/8"(181)wall thickness.Other wall dimensions can be accommodated with extension jamb modification.Extension Unit Dimension Width jambs are pre-drilled for easy application. Rough Opening Width Width Horizontal Section Interior Extension Jambs:The use of Full panel interior extension operation jambs will restrict Installed flush Restricted panel panel operation on to interior wall i operation jamb hinged doors. Jamb hinged patio Optional Andersen° doors must be extension jambs installed flush to the interior to achieve full Exteriortrim and 1-3/4"(44) panel operation. flashing by others— Jamb hinged patio door In 2 x 6 wall Jamb hinged patio door In 2 x 6 without extension lambs wall with extension lambs R E V. 1 2 0 6 A R C H I T E C T U R A L D E T A I L F I L E 26-7 Andersen®; . : �� k :Y�r�r �� � :. r ����d # �:._�4 .;rW,I:�W,D O�WaS'• D 0�O'R�S�9®. � �� y t i a. a �, n�, �,Y• � 'f: us.„ �.^,, Anchoring Methods Scale 3" — 1'-0" (1:4) Wood Screw Fastener/Flange in Standard Position Wood Screw Fastener/Flange in Reversed Position Patio door unit is secured in opening using wood screw fasteners through the jamb Patio door unit is secured in opening using wood screw fasteners through the (the flange itself cannot support the door). jamb(the flange itself cannot support the door). Wood screw V,,c Wood screw fastenerh fastener CP 4 Exterior sheathing ............... Flange in Flange reverse position i"77777;� 5— Threaded Masonry Fastener Expansion Sleeve Make sure that the unit frame parts do not become bowed when using anchoring methods.Unit will not Patio door unit is secured in opening by pre-drilling through side jamb into masonry. operate properly if frame parts are stressed. Threaded masonry fastener t . ti 0 Flange removed 26-8 A R C H I T E C T U R A L D E T A I L IF I L E R E V.1 2 0 6 Andersen® y wiluoows • 000Rs ®, Hinged Patio Doors = Inswing Joining Details Andersen® Joining Materials Scale 3" = 1'-0" (1:4) Joining Compatibility Many Andersen'units are designed to be joined with other Active Panel Stationary Panel Andersen units in a variety of non-reinforced and reinforced 3/4"(19) z (51) 3/4"(19) combinations.Other combination types and joining methods can be viewed in the Andersen'Product Guide for Professionals, extension Intedortdm and jambs by others in Andersen Window Studio°software,and by visiting andersenwindows.com.Combination designs should always be Structure by others checked for design pressure Derformance requirements to make I I sure the appropriate joining method is specified. I I i I I i I i I I I I I I I I Optional Andersen° 2"'(51) Optional Andersen®2"support 2 support mullion mullion trim strip set in continuous woad filler bead of sealant each side 2" Support Mullion Frenchwood®Patio Door Transom x 0 Optional Active Panel Stationary Panel Andersen° e 3/4"(19) reinforced LVL o 3/4"(19) 3/4"(19) joining strip Optional Andersen® 1"(25) wood casing 3/4"(19) 3/4"(19) i 3/4"(19) Trim strip set in continuous bead of sealant m each side = 0 c E 0 Trim strip set in continuous �--� Optional Andersen® bead of sealant each side 3/4..(19) reinforced LVL joining strip Inswing Patio Door Andersen® LVL Reinforced Mullion Andersen® LVL Reinforced Transom REV. 12/06 A R C H I T E C T U R A L D E T A I L F I L E 26-9 � Y,.. .. „�.e...«.,..,n,«-.,`:`"`.'«-".«.`.."' �j•-- - ._ �-.+..-mss +.--...-r- y ^Iry � r .. .we-n LN:oo�.ws • oo'o.R5"1 ged Patio, D,00'rs,�- I`nswfng'a Suggested Product Applications Wall Types y Scale 1-1/2" = V-0" (1:8) Remove flange at head and Flange at he jambs and jambs Optional Andersen® insect screen Head Head 3/8" 3/8„ (10) ; (10) I .P t eu x N L L OD x Up 45 C v3 a� _ o 2 0 m � � m = m E E E E o o E > > E Jamb Jamb Optional Andersen' insect screen e SIII SIII Vertical Section Vertical Section Wood Siding/ 2 x 4 Wood Stud Framing Brick Veneer/ 2 x 6 Metal Stud Framing Minimum Rough Opening Rough opening dimensions shown are the minimum dimensions recommended for proper installation.These dimensions.may need to be increased to allow for use of building wraps, flashing,sill or pan flashing,brackets,fasteners or other items which could decrease these dimensions.Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer. Importance of Proper Installation Proper installation and maintenance ofAndersen'products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available forAndersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12,Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. Construction by Others Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units. NOTE:Where E.I.F.S.wall finish is adjacent to units,contact E.I.F.S.manufacturer for installation Instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealant joint around the perimeter of the unit. NOTE:Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.Flange may be removed where construction sequence/detailing requires no flange. 26-10 A R C H I T E C T U R A L D E T A I L F I L E R E V. 1 2/0 6 777,17-74 , det. •,rsen � 4^,Y .,. 000li`s.® is etl. Pafio`' Doto,ers 'Iliswiri vurrvo�ow;�s. aH n';g g. °�:.�<<,l:'n•s; Suggested Product Applications Wall Types Flange at head a /V10- O/ and jambs ®B ..a Exterior trim by others Optional n Andersen' I(�J insect screen Membrane Head Head flashing over flange(by others) s e , 3/8' 3/8„ (10) r (10) u x m � L � bLD t :2 :R C 0 o p o 0 0 E E o E D p p E E Jamb Jamb Optional Andersen' insect screen a o a` o.p Sill sill Vertical Section Vertical Section E.I.F.S./ Concrete Masonry Unit (CMU) Brick/ Concrete Masonry Unit (CMU) Minimum Rough Opening Rough opening dimensions shown are the minimum dimensions recommended for proper installation.These dimensions may need to be increased to allow for use of building wraps, flashing,sill or pan flashing,brackets,fasteners or other items which could decrease these dimensions.Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer. Importance of Proper Installation Proper installation and maintenance of Andersen`products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available forAndersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12,Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. Construction by Others Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units. NOTE:Where E.I.F.S.wall finish is adjacent to units,contact E.I.F.S.manufacturer for installation Instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealardjoint around the perimeter of the unit. NOTE:Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.Flange may be removed where construction sequence/detailing requires no flange. REV. 12/06 ARCH ITECTU RAL D E T A I L FILE 26-11 .:.-..-..ry..v.,.-.�Y,er«.....7 7 �w7777*"^ =,n--.y..,' --777— Andersen w'IND:O''WS �oo.o,Rs ®; Hinge�d Patio` Doo`r`s°' Inawrn,g h Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) Exterior trim ® ' by others Exterior trim Existing by others frame wall 1-3/16"(30) Flange at head Flange at head and jambs and jambs Head Head z. 3/8„ Exterior trim 3/8" (10) m by others (10) g x x L LD C) DLII L bCD = N M G 3 d 0 o O o O C N pLp N N pLp 'J- o E ¢ E E rr > > E = E E Jamb Jamb Optional Optional Andersen® ® Andersen' insect screen insect e screen 0 0 Sill sill Vertical Section Vertical Section Stucco / Concrete Masonry Unit (CMU) Inset Door Existing Wall Minimum Rough Opening Rough opening dimensions shown are the minimum dimensions recommended for-proper installation.These dimensions may need to be increased to allow for use of building wraps, flashing,sill or pan flashing,brackets,fasteners or other items which could decrease these dimensions.Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer. Importance of Proper Installation Proper installation and maintenance of Andersen'products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12,Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. Construction by Others Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units. NOTE:Where E.I.F.S.wall finish is adjacent to units,contact E.I.F.S.manufacturer for installation instructions,Including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealant joint around the perimeter of the unit. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.Flange may be removed where construction sequence/detailing requires no flange. 26-12 A R C H I T E C T U R A L D E T A I L F I L E R E V. 1 2/0 6