Loading...
HomeMy WebLinkAbout49474-Z r��• - o�guFFot�-coG Town of Southold 9/24/2023 P.O.Box 1179 ti 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44594 Date: 9/24/2023 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 2200 Park Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 123.-8-10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/7/2023 pursuant to which Building Permit No. 49474 dated 7/14/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"alterations, including window&door replacements,to pre-existing single-family dwelling(rear waterside house). The certificate is issued to JSK Park Ave LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49474 9/5/2023 PLUMBERS CERTIFICATION DATED Aut ri ed -N'*' tu-re TOWN OF SOUTHOLD �o�gUfFQ( aye BUILDING DEPARTMENT C* g E TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49474 Date: 7/14/2023 Permission is hereby granted to: JSK Park Ave LLC 159 W 24th St Apt 713 New York, NY 10011 To: legalize "as built" window & door replacements to pre-existing single-family dwelling (rear waterside house). At premises located at: 2200 Park Ave, Mattituck SCTM #473889 Sec/Block/Lot# 123.-8-10 Pursuant to application dated 6/7/2023 and approved by the Building Inspector. To expire on 1/12/2025. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CO-ALTERATION TO DWELLING $50.00 Total: $450.00 Building Inspector oF so�ryOlo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 aQ Jamesh _southoldtownny.gov Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: JSK Park Avenue LLC Address: 2200 Park AVE [rear waterside house] city:Mattituck st: New York zip: 11952 Building Permit#: 49474 Section: 123 Block: $ Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Homeowner Electrician: License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 100 A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: Notes: AS BUILT SERVICE Inspector Signature: Date: September 5, 2023 2200 park ave rear house waterside j I SOUIyo '��q 7q ,X vv l'ar K K-Lu e # TOWN OF SOUTHOLD BUILDING DEPT. �o • �O `ycoum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ear C,+P-V-,5 i0te WOCA15e, Str%J iG,o- Lw arab- A-e-eA Cky G,i o ri Ole, DATE D` a3 INSPECTOR SOUIHp� TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] RO PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 411 ��oy� INSPECTOR DATE INSP R C O ►.jam t..� � �!'� •�.a .c• � ... x ; • .;x �.A '•,�S�c-�� ']+ � •mss yr •a .[s.r�.. FIELD INSPECTION REPORT DATE COMMENTS 'S9 FOUNDATION (1ST) y ------------------------------------ .�.�CC n FOUNDATION (2ND) z N ° N G Oy ROUGH FRAMING& PLUMBING 1 C INSULATION PER N.Y: STATE ENERGY CODE r FINAL y ADDITIONAL COMMENTS l� arv- r b N N O z y x d b y sUfFOt* oS TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowm.aov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only , PERMIT NO. Building Inspector: JUN — 7 2023 Applications and forms°must be filled out in their entirety.Incomplete ; applications will not be accepted. Where the Applicant isnot the owner,an . Tr _. O,wner's Authorization form(Page:2)shall be completed. Date:6/5/2023 OWNER(S)OF'PROPERTY: Name:JSK PARK AVENUE LLC SCTM# 1000-123.-8-10 Project Address:2200 PARK.AVENUE, WTTITUCK NY 11952 (REAR WATERSIDE HOUSE) Phone#:g 17-520-9967 Email:SKI M_YTD97@HOTMAIL.COM;JSIREF MAN@SIREFMANVENTURES.COM Maili,ngAddress: 150 HICKS„STREET-#4A, •BROOKLYN,.•NY 1.1201, .. _. ...-._..,....... _. ._. CONTACT PERSON: : Name: MARTLN D._FINNEGA.N_(FI;NaNEGAN LAW,.P._...)_ Mailing Address:PO BOX_145,2. 1„3250 MAIN ROAD,, MATTI,TUCK, NY 11952 Phone#:631-315-6070 Email:MFINNEGAN@NORTH FORK.LAW DESIGN PROFESSIONAL INFORMATION: Name:TBD Mailing Address: Phone#: Email: CONTRACTOR I,NF:ORMATION: Name:TBD Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: FilOther AS-BUILT WINDOWS&DOORS $N/A Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY-INFORMATION is Extin f Intended ert -- ._ . guse oproperty: RESIDENTIAL. ..__.. .__p_ y._RES.I_DENTIALntdd use ofr : _. _-_ . ._ p_.p . v..R.ES_IDE_NTIAL.,-_--_-,_-- Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_40 this property? ❑Yes ®No IF YES, PROVIDE A COPY. B Check"Box After Reading: The owner/contractor/design professional is responsible'for all drainage and storm water issues as provided by, Chapter 236 of the Town Code:APPLICATION IS HEREBY MADE to.the Building Department for the issuance of,a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises,and"in building(s)for necessary inspections.False statements made herein are - punishable asClass A misdemeanor pursuant to Section 230AS of the New York State Penal Law. Application Submitted By int na ); MARTIN D. FI N N EGAN BAuthorized Agent ❑Owner Signature of Applicant: Date: 6/5/2023 STATE OF NEW YORK) SS: COUNTYOF SUFFOLK ) MARTIN D. FINN EGAN being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the AGENT (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this (� dayofJUNE , 2023 Notary Public SCHWEITZER ANNALISE PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC NO.01SC6409457 NEW YORK (Where the applicant is not the owner) QUALIFIED IN SUFFOLK COUNTY Z MY COMMISSION EXPIRES SEP 28.20 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) SARAH KIM, SOLE MEMBER OF 1JSK PARK AVENUE LLC residing at 159 WEST 24TH STREET, APT. 713, (Print property owner's name) (Mailing Address) NEW YORK, NY 10011 do hereby authorize MARTIN D. FINNEGAN (Agent) to apply on my behalf to the Southold Building Department. Wqho Z. (� y n is Signature) (Date) ,r JSK PARK AVENUE LLC BY: SARAH KIM, SOLE MEMBER (Print Owner's Name) ©�vsufFOj,g-t�Gy BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD C* Town Hall Annex - 54375 Main Road - PO Box 1179 ton . Southold, New York 11971-0959 'yfj0 �O� Telephone (631) 765-1802 - FAX (631) 765-9502 1 ' rogerr(&southoldtownny.gov seandCZD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: 6/7/2023 Company Name: HOMEOWNER Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: JSK PARK AVENUE LLC Address: 2200 PARK AVENUE, MATTITUCK, NY 11952 (REAR WATERSIDE HOUSE) Cross Street: MARRATOOKA ROAD Phone No.: 917-520-9967 -JOSHUA SIREFMAN Bldg.Permit#: �ffL7V email: MFINNEGAN@NORTH FORK.LAW Tax Map District: 1000 Section: 123.00 Block: 08.00 Lot: 010.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): UPGRADED ELECTRICAL SERVICE AND PANEL WITH ROMEX WIRING. Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO —]Rough In Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame M Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION � 0 � 1 BUILDING DEPARTMENT- Electrical Inspector Gyp TOWN OF SOUTHOLD y a Town Hall Annex- 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 'ffj� ao� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov - seande-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: JSK PARK AVENUE LLC Address: 2200 PARK AVENUE, MATTITUCK, NY 11952 (FRONT ROADSIDE HOUSE) Cross Street: MARRATOOKA ROAD Phone No.: 917-520-9967-JOSHUA SIREFMAN Bldg.Permit#: email: MFINNEGAN@NORTHFORK.LAW Tax Map District: 1000 Section: 123.00 Block: 08.00 Lot: 010.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): UPGRADED ELECTRICAL SERVICE AND PANEL WITH ROMEX WIRING. "WA�C(5&, house Square Footage: Circle All That Apply: Is job ready for inspection?: 7YES ❑ NO ❑Rough In Final Do you need a Temp Certificate?: ❑ YES 0✓ NO Issued On Temp Information: (All information required) Service Size 1-11 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 H Frame Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION vJt y-iCvw�- or ��� �S�fFpj� O BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD C= Town Hall Annex - 54375 Main Road - PO Box 1179 C1* • Southold, New York 11971-0959 ®� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCaD-southoldtownny.gov - seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 6/7/2023 Company Name: HOMEOWNER ` Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: JSK PARK AVENUE LLC Address: 2200 PARK AVENUE, MATTITUCK, NY 11952 (REAR WATERSIDE HOUSE) Cross Street: MARRATOOKA ROAD Phone No.: 917-520-9967 -JOSHUA SIREFMAN Bldg.Permit#: �ff7 V email: MFINNEGAN9NORTHFORK.LAW Tax Map District: 1000 Section: 123.00 Block: 08.00 Lot: 010.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): UPGRADED ELECTRICAL SERVICE AND PANEL WITH ROMEX WIRING. Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In 0✓ Final Do you need a Temp Certificate?: ❑ YES [7 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals F 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION I c o Fw e VUIr2. P-f IIM,0IL VX L�� 30 V.:ge4 PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments S.C.T.M.# DISTRICT 1000 SECTION 123 BLOCK 8 LOT 9 & 10 `1' U.P./ \\AGc' R 0 W.V. (_ \ U.P. o' 'Y 10 OAK PS / SSS S°1 \zO!oaK \ t970f PP�,tt•E�h lo' Loc. £ 20�oac q 6' .14:4....... \ 10•• 62ri >�a__OAKgh £ '\ 99 � t9h \\o \\ 1 STY FRAME: e;,DWELLING vi. s• ::•:i:' \ Yn\ `y}\ •FFL=21.7 �D y:::IIF200 4 STYE' :--FRAME-.'.'.._". CON O ..'::`DWELLING::: \F v�\\ v2 PATIO J V' U.P. O� v'FFL=21.6: : EXISTING LOT COVERAGE //2150!::::: AREA LANDWARD RD OFCRESTOFBANK27869 S.F.Or O.64 ACRES P`) £ OWELLING(NORTH):1081 S.F. o oa SHED:76 S.F. DWEUING(SOUTH):1684 S.F. II � TOTAL 2841 S.F.or 102% oPpp PATIO 4.J q`' I ASPHALT DRIVEWAY T .S / \I4'OAK (C.P.) ( 'g�'�\ T8 EXISTING LOT COVERAGE22'oa AREA LANDWARD OF CREST OF BANK 27495 S.F.or 0.63 ACRES DWELLING(NORTH):1081 S.F. �� \ 4 4'0'OAS.oax CI \\ SHED:78 S.F. \\ Q \ \ DWELLING(SOUTH}1684 S.F. 0 { z 16'OAK TOTAL:2841 S.F.or 10.3% 15' Q \ 14�'?OAK j 6'OAK 6'OAK \ 20�• 10'OAK 6OAK Y7 es to Jo S.C.T.M.#1000-123-8-11.3 1.a•w 7 I LAND N/F OF `q1 1� IQAI( I 1O'oaK P. i o I 18'OAK CNC PARK AVENUE LLC 20'OAK I t✓ l0'OAK 76 6'OAK I I4'OAR (''''� 1B"OAK ,.fit 8'OAK No 6.OAK I N Q � ' 10 I a•, \t 10'OAK o•OAK (10 DWELLINGS w z 4 6 ON, I w 6'0" W/PUBLIC WATER I4 oaK ca q`+ �6,am \ 150' s OAK Q r .. \16'OAKV OAK d \ 14 OAK . `' 14'0- pS 2.7' 181"O OAK ,� 'Oa is S.C.T.M.#1000-123-8-8.3 Up 3 LAND N/F OF e 9 TIMOTHY MURRAYASPHALT s' P. DWELLINGS \ DRIVEWAY W/PUBLIC WATER 29•E 150' IT oAK s lo' K �m 'y I4'OAK MON. 9 . Qt\D�''+� 10'oi. 10'K 14.OAK { b I6 12'OAK d S to 18'OPX 1( K 8'OAK / t6h \IO'OAK t W b °• .'r F 6' SHOWER to O f0'OA41 K \£ FENCE 1*5.::' ELEV. 18.2 16. SM BROWN SILK SAND 5,0• .:O Nor"',c� PALE BROWN ::..:.t➢.FINE ...P: i SP SAND ' 224' 37' C 17.3' a7':i:::i'i....;:';��::::. -PF WATER IN .:.•:;.:" 40` SP 159 FINE t PP ZONE X �'1._ �q 12T SAND 28' —18' 2y 72 29' APRIL 15, 2022 McDONALD GEOSCIENCE i�,p.l E.OGE K01 P -ZONE BOUNOARI' 000 irii / 5 X18 ,61 /o �^� � B /O�PpO 15 /-74"o V eV� WptER / o 41 FEMA MAP#36103CO482H /51p5p3q ao AREA:59,791.66 SQ.FT. or 1.37 ACRES ELEVA77oN DATUM;_NAVD88 -- 42 V ZONE VE(EL 8) UNAUTHORIZED ALIERA770M OR ADD17ION TO THIS SURVEY IS A WOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCARON LAW. COPIES OF THIS SURVEY �,/ `'105038 ONS MHW MAP ONLYNTo THE POT ING ERSON£LAND FOR WHOM THE SURVEY ISSED SEAL SHALL NOT PREPARED AND ON HISEBEHALFERED TO BE A VALID TO THE TITLE COMPANY,E COPY. GUARANTEES GOVERNMENTAL AGENCY ANDATED HEREON SHALL LENDNG INS7ITUTONRUN / �E LINES PL LISTED HEREON,AND TO THE ASSIGNEES OF THE LENDING WS77TU770N, GUARANTEES ARE NOT TRANSFERABLE. S THEOFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE MHW EQUALS TIDAL WEBAND BOUNDARY AS ULTANT 11 BY A NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE EREC77ON OF FENCES ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS. EASEMENTS Lis AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE 77ME OF SURVEY EN-CONSULTANTDETERS I I-09-22 -t f SURVEY OF:DESCRIBED PROPERTY OF Nety CERTIFIED TO: JSK PARK AVE, LLC; oo Q�C01�Z MAP OF: tiP SN M. N,OPI'0� oOoi Y FILED: SITUATED AT:MATTITUCK o TOWN ORSOUTHOLD n KENNETH M {YOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK "0 050882P Professional Land Surveying and Design SJ P.O. Box 153 A uebo ue New York 11931 SUPPLY, WELLS, DRY CLS AND CESSPOOL 4 g LOCATIONS SHOWN ARE FROM FIELD OBSERVATIONS FILE 8222-113 SCALE:1 —30' DATE:AUG. 30, 2022 N.Y.S. LISC. N0. 050882 PHONE(831)298-1588 FAX(631)298-1588 AND OR DATA OBTAINED FROM OTHERS. r:Andersen ® ... .. WIND,OW$�D-OORS . Tilt-W;asfi ,Dou.ble=HunWindows Contents Tilt-Wash Double-Hung Windows Basic Unit Details- i Tilt-Wash Double-Hung Windows for 4-1/2"Wall...............................................19-2 Basic Unit Details Picture Transom and n- d Circle TbpTm Windows with Extension Jambs......................19-3 Basic Unit Details- 1 F .......... �.. - Tilt-Wash Double-Hung Windows with Drywall Return.........................................19-4 Basic Unit Details- to `Qi";," }} '> r; Picture,Transom and Circle TopTM Windows with Drywall Return.........................19-5 Options/Accessories Andersen®Grilles.......................................................................................19-6 Extension Jambs g Windows - Stool Applications..........................................................................19-7 20/10 year limited warranty,fully transferable, Extension Jambs for Picture,Transom and Circle TopTm Windows......19-8 non-prorated Trim Options and Applications Low-E or dual pane insulating glass Plinth Blocks for Circle TopTm Windows..............................................19-9 White or sandtone vinyl clad low-maintenance Interior Casing for Circle Topa"Windows.........................................19-10 exteriors Narrow profiles for larger glass area Joining Details for 4-1/2"Wall ........................................................................19-11 • An in-sash balancer to minimize the view of Joining Details with Drywall Return..................................................................19-12 • thejamb liner Anchoring Methods.........................................................................................19-13 Clear pine or optional prefinished white Suggested Product Applications......................................................................19-14 interior Innovative sizing format to simplify ordering and installation APPR VED'AS NOT D/ / DATE. 3.B:P.•# 47� FEE:- ,by: COMPLY WITH ALL CODES OF NOTIFY.;BUILDING DEPARTMENT AT NEW YORK STATE & TOWN CODES 765=1802 8 AM TO .4 PM FOR THE AS REQUIRED AND CONDITIONS OF FOLLOWING:INSPECTIONS: 1. FOUNDATION;,- TWO REQUIRED #6L$�_ FOR POURED CONCRETE. SO1N-PtANNING BOARD 2. ROUGH = FRAMING &. PLUMBING s. INSUCATiON S8UTH6tBfi6t VRUSTEES 4. FINAL,-:,.:;'CONSTRUCTION MUST N BE COMPLETE FOR C.O. ALL,CONSTRUCTION SHALL MEET THE e GU_HANGY OR S OF THE CODE'SNEW YORKIREMENSTATE•NOT R SPONSIBLOEF FOR JSE IS-UNLAWFUL DESIGN OR CONSTRUCTION ERRORS. NITHOU ,E MFICATL� FONCY R E V.0 3/0 5 A R C H I T E C T U R A L D E T A I L F I L E 19-1 - Andersen - _ aWIND'ows,•-D:06k:S ®. Tj.1t-Wash...Dou,b1•e-Hung -W.,indow-s Basic Unit Details `.—_f^---------------------- --- ----- ----------------------- Tilt-Wash Double-Hung Windows for 4-1/2"Wall Scale 3" = 1'-0" (1:4) 4.1/2° (114) 1-5/16" 2.5/8" 1-7/8" (33) (67) (48) 1/4" Optional (6) insect screen 11/16"(17) 1/2"(13) 3" � (76) 1-7/8"(47) = Head y (7 bD SP = x 2-1/8"' (54) 1-13/16" o d (46) d n d O E -- en � o Lower sash in m - full open position m M Check Rail x m 0 0 m _ 1-7/8"(47) 3" (76) 9 1/2"(13) 11/16"(17) 1/4" (g) sill Vertical Section 1/2" 1-13/16" 1/2" 1-13/16" 11/16" (13) (46) 11/16" (13) (46) (17) Lower (17) Lower sash sash 4-1/2" 4.1/2" (114) (114) 3-3/16" Upper 3-3/16" Upper (81) sash (81) ----- --- — sash 1-5/16" 1-5/16" (33) (33) 1l Jamb 3" 31. Jamb Jamb 3" 3" Jamb (76) Glass Width (76) (76) Glass Width (76) Unit Dimension Width Unit Dimension Width 1/4" 1/4" 1/4" 1/4" (6) Rough Opening Width (6) (6) Rough Opening Width (6) Horizontal Section Horizontal Section Through Upper Sash Through Lower Sash 19-2 A R C H I T E C T U R A L D E T A I L F I L E REV.03/05 JL ndersen ® Y ;:.WANp6'W,s •.DVORs, T,IIt-Wash D.Oub'le-H,ung W(ntlo;w.s.. ) Basic Unit Details Picture,Transom and Circle TopTm Windows with Extension Jambs Scale 3" = 1'-0" (1:4) 4-1/2"(114) 4-1/2"(114) 1-5/16" 3-3/16" 1-5/16" 1-5/16" 3-3/16" 1-5/16" (33) (81) (33) (33) (81) (33) Optional Andersen® 1/4" extension jamb 1/4" Optional Andersen® (6) (6) extension jamb 11/16"(17) _ 11/16"(17) 3/8"(10) 3/8"(10) 3„ 3" (76) (76) 1-15/16"(49) 1-7/8"(47) nn � m tin � bD OO bD o = Head Ei O Q N o Head o E m o E m 3" 1-15/16"(49) 3„ 1-7/8"(47) (76) (76) 3/8"(10) 3/8"(10) 11/16"(17) q �, 11/16"(17) 1/4" 1/4„ Sill (6) Sill (6) Vertical Section Vertical Section Picture or Transom Circle Top"' Unit 3/8" 1-15/16" Optional Andersen® 3/8 1-7/8" Optional Andersen® 11/16" (10) (49) extension jamb 11/16" (10) (47) extension jamb (17) (17) '4w r a., 4-1/2" 4.1/2" (114) 3-3/16" (114) 3-3/16" (81) (81) 1-5/161, (33) (33) 3" 3" 3" 3" Jamb (76) Glass Width (76) Jamb Jamb (76) Glass Width (76) lamb 1/4" Unit Dimension Width 1/4" 1/4" Unit Dimension Width 1/4" (6) (6) (6) (6) Rough Opening Width Rough Opening Width Horizontal Section Horizontal Section Picture,Transom Circle Topes" Unit R E V.0 3/0 5 A R C H I T E C T U R A L D E T A I L F I L E 19-3 ;Andersen® ,.,WINDOWS -.DOO-RS Tilt-W:ash , Double-Hung Win.tl-o.ws -. Basic Unit Details Tilt-Wash Double-Hung Windows with Drywall Return Scale 3" = 1'-0" (1:4) 1-5/16" 3-1/16" (33) (78) Drywall return 1/4" Optional (6) insect screen 1-1/16"(27) L II II' bL = Head m m x x 2-1/8" 1-13/16" m o (54) (46) a o E -- L 0 Lower sash in ;o full open position :2P C2 H Check Rall _ CD uu a 0 m U 1-7/8"(47) 3" (76) 1-1/16"(27) 1/4" (6) SIII Vertical Section 1-1/16" 1.7/811 1-1/16" 1.7/8" 27) (47) (27) (47) Lower Drywall Lower Drywall sash return sash return 3-1/16" Upper 3-1/16" Upper (78) Asash (78) sash ----- — r 1-5/16" 1-5/1611 ---- ----- (33) (33) Jamb 3" 311 Jamb Jamb 31' T. Jamb (76) Glass Width (76) (76) Glass Width (76) 1/4" Unit Dimension Width 1/4„ 1/41 Unit Dimension Width 1/4" (6) Rough Opening Width (6) (6) Rough Opening Width (6) Horizontal Section Horizontal Section Through Upper Sash Through Lower Sash 19-4 A R C H I T E C T U R A L D E T A I L F I L E R E V.0 3/0 5 . Andersen®. WINDOWS - D6ORS_ Tilt-W,as°h '_Do'.u.b_le,-Hun Windows Basic Unit Details Picture,Transom and Circle Top' Windows with Drywall Return Scale 3" = 1'-0" (1:4) 1-5/16" 3-1/16" 1-5/16" 3-1/16" (33) (78) (33) (78) 1/4" Drywall return Drywall return (6) (6) 1-1/16"(27) 1-1/16"(27) 3" 3" (76) u u u u vi YLI C :� bll C bD yHead = Head o E A o E m 3 1.7/8"(47) 3„ 1-7/8"(47) (76) (76) 1-1/16"(27) 1-1/16"(27) 1/4" 1/4� *sill (6) SIII (6) Vertical Section Vertical Section Picture or Transom Circle TopTm Unit 1-1/16" 1-7/8" (27) (47) (27) (47) Drywall return Drywall return Af 3-1/16" 3-1/16" (78) (78) 1-5/16" 1-5/16" (33) (33) 3" 3" 3" 3" Jamb (76) Glass Width (76) Jamb Jamb (76) Glass Width (76) Jamb Unit Dimension Width 1/4" 1/4" Unit Dimension Width 1/4" (6) (6) (6) (6) Rough Opening Width Rough Opening Width Horizontal Section Horizontal Section Picture,Transom Circle Top'm Unit REV.03/05 ARCH ITECTU RAL D E T A I L F I L E 19-5 :Andersen ® iwIN,D.o,Ws.• DOORs : Ti It" W.ash _ Do.u,:b.le=Hung W'indows .. Standard Grille Options / Accessories Contact an Andersen Representative for project specific grille options. 200 Series Grille Options Removable Interior Andersen'Finelight' Grilles-Between-the-G lass Grille Profiles scale = Full Removable Interior Wood Grille Profiles(chamfer profile). T— T— T- 7/16" 7/16" 7/16" L L L 3/4" 7/8" I 1-1/8" Andersen'Finelighr Grilles-Between-the-Glass 3/8" 1/2" 3/4" 1" Window Profile Patio Door Profile 19-6 A R C H I T E C T U R A L D E T A I L F I L E REV.03/05 I Andersen® iw,liao.ows4o;O,OR$ ®:. Tilt-Wash° .Do'u,,ble-.Hu`ng Windows Options / Accessories Extension Jambs for Tilt-Wash Double-Hung Windows Scale 3" = 1'-0" (1:4) 9/16" _ (14) 4-1/2n v \ Wall LL UJ 7-1/8" 6-9/16" 5-1/4" Wall Wall Wall v M M (O � _ N V � C Jamb Horizontal Section Extension jambs available for 5-1/4"(133),6-9/16"(167)or 7-1/8"(181)wall thickness. Other wall dimensions can be accommodated with extension jamb modification. Options / Accessories Stool Applications (by others) Scale 3" = 1'-0" (1:4) Stool (by others) � Stool (by others) d 0 Sill SIII Vertical Section Vertical Section Tilt-Wash Double-Hung Picture,Transom or Circle Topes" Units REV.03/05 A R C H I T E C T U R A L D E T A I L F I L E 19-7 is Andersen . i_ k.so. s ' TII'tf-Wash�.-bSOub.I'e=Hun W.in-lows' Options / Accessories Extension Jambs for Picture,Transom and Circle Toprm Windows Scale 3" - V-D" (1:4) 7-1/8"(181) 7-1/8"(181) 6-9/16"(167) 6-9/16"(167) 5-1/4"(133) 5-1/4"(133) 4-1/2"(114) 4-1/2"(114) I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I -t- 1-- 1--4.-- I t I l V I l I l 11 I I I I I I = I I I I 1 u l Optional I II I - I I I II I Andersen® arch casing Face: Face: 1-5/16"(33) 4-1/2"Wall 1-5/16"(33) 4-1/2"Wall / 711/16"(17) -_-_-_ 1 11/16°(17) Face: Face: 2"(51) 5-1/4"Wall 2"(51) 5-1/4"Wall 1/8"(3) 1/8"(3) Face: Face: 3-5/16"(84) 6-9/16"Wall 3-5/16"(84) 6-9/16"Wall ��► illi DI ==_--= _ Face: Face: 3-7/8"(98) 7-1/8"Wall 3-7/8"(98) 7-1/8"Wall Picture/Transom-Head Circle Top-Head I 1 I I 1 I 1 I 1 1 Picture/Transom-SIII Circle Top-SIII Vertical Section Vertical Section Picture/Transom Units Circle Top'' Units Extension jambs available for 4-1/2"(116),5-1/4"(133),6-9/16"(167)or 7-1/8"(18 1)wall thickness. Other wall dimensions can be accommodated with extension jamb modification. 19-8 A R C H I T E C T U R A L D E T A I L F I L E REV.03/05 AndersenY WINDO.WS •''D,o.O.:RS ® .TIlt--K,a ;h DoUb'.Ie,-;'Hu:n :,,W,in.;dows+__ Trim Options and Applications_ Plinth Blocks for Circle Topp" Windows `^ Scale: Half Available in maple, oak and prefinished white. Optional Andersen® interior arch casing (Colonial or Ranch styles) 2-1/4"Colonial Style Also available in prefinished white Optional Andersen' with prefinished transom casing plinth block applied. Optional Andersen plinth blocks Interior trim by others 1-1/8"-R 3-7/8"(98mm) 2-7/8"(73mm) 2-7/8"(7 mm) 3-7/8"(98mm) 7/8"(22mm) 7/8"(22mm) For use with 2-1/4"or 2-1/2"(57mm or 64mm)casing. For use with 3-1/2"(89mm)casing. REV.03/05 A R C H I T E C T U R A L D E T A I L F I L E 19-9 Andersen W.INDOW S -.qo:o-R.s ,®-,:Til.t,-Wash. Roub,le=Hung Window's Trim Options and Applications Interior Casing for Circle Top' Windows Scale: Full Available for all curved portions of windows. Ranch Style-WM 315 2-1/2"x 11/16"(64mm x 17mm) Available in maple only. Ranch Style-WM 324 2-1/4"x 11/16"(57mm x 17mm) Available in maple or oak. Colonial Style-WM 351 2-1/2"x 11/16"(64mm x 17mm) 5/32"(4mm)typical Available in maple only. XI IMP V Colonial Style-WM 366 2-1/4"x 11/16"(57mm x 17mm) Available in maple or oak. Also available prefinished white with prefinished plinth black attached. Colonial Style-WM 444 Optional Andersen® 3-1/2"x 11/16"(89mm x 17mm) extension jamb Available in maple or oak. CircleTopTM'Window 19-10 A R C H I T E C T U R A L D E T A I L F I L E REV.03/05 Andersen® _ • WINDOW,S •'DOORS ®`, Tilt.-Wash. Do,ubl.e-H:u.ng .Windo'ws; Joining Details Tilt-Wash Double-Hung, Picture,Transom and Circle TopTM Windows for 4-1/2" wall Scale 3" = 1'-0" (1:4) 1-11/16" 1-11/16" (43) (43) Optional Andersen° Optional Andersen" Double-Hung Double-Hung casing Plcture/Transom Double-Hung casing Jamb Jamb Jamb Jamb Optional Andersen° extension jamb Optional Andersen° Optional Andersen° non-reinforced wood non-reinforced wood r, i ---- joining material -----, -- "---- , � joining material -------------------- Unit Dim. Unit Dim. Optional Andersen" Vim strip Unit Dim. Unit Dim. Optional Andersen" trim strip 1/2"(13) 1/2"(13) Horizontal Section Horizontal Section 1-11/16" (43) Optional Andersen" Joining Compatibilty Picture ransom Picture casing Picture/Transom casin Jamb Jamb Many Andersen®units are designed to be joined with other Andersen Optional , units in a variety of non-reinforced and reinforced combinations.Other Andersen" extension YP and joining types oinin methods can be viewed in the Andersen � combination jambs a Product Guide for Professionals,in Andersen Window Studio®software, and by visiting www.andersenwindows.com.Combination designs should Optional Andersen" always be checked for design pressure performance reouirements to non-reinforced wood joining material ensure the appropriate joining method is specified. Unit Dim. Unit Dim. Optional Andersen° trim strip 1/2"(13) Horizontal Section Picture/Transom/Circle TopTM'Unit-Sill Picture/Transom/Circle Top'"Unit-Sill Optional Andersen" Optional Andersen" ° extension jamb m extension jamb x c c Optional E Optional Andersen" Optional E Optional Andersen° Aim stn n® iS casing Andersen° o casing P trim strip—= 1/2"(13) - 1-11/16"(43) 1/2"(13) (43) 'd x 4 o EOptional Andersen° d Optional Andersen" o non-reinforced wood o non-reinforced wood joining material _ joining material Double-Hung-Head Picture/Transom-Head Vertical Section Vertical Section REV.03/05 A R C H I T E C T U R A L D E T A I L F I L E 19-11 ; Andersen® WINDOWS • Do0RS.. Tii.t.-Wash Double_-H up.g Windo-w.s: Joining Details Tilt-Wash Double-Hung, Picture,Transom and Circle TopTm Windows with Drywall Return Scale 3" = 1'-0" (1:4) 1-11/16" (43) 1-11/16" Double-Hung Double-Hung (43) Jamb Jamb Picture/Transom Double-Hung Jamb Jamb Optional Andersen® casing Optional Andersen casing Optional Andersen® Optional Andersen® r - - -- non-reinforced wood non-reinforced wood - - joining material ---- joining material Unit Dim. Unit Dim. Optional Andersen° Unit Dim. Unit Dim. Optional Andersen" Vim strip trim strip Horizontal Section Horizontal Section 1-11/16" Picture/Transom (43) Picture/Transom Jamb Jamb Optional Andersen" Joining Compatibilty casing Many Andersen®units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations.Other combination types and joining methods can be viewed in the Andersen® Optional Andersen" Product Guide for Professionals,in Andersen Window Studio'software, non-reinforced wood joining material and by visiting www.andersenwindows.com.Combination designs should always be checked for desion,oressure performance requirements to ensure the appropriate joining method is specified. Unit Dim. Unit Dim. Optional Andersen" trim strip 1/2"(13) Horizontal Section Picture/Transom/Circle TopTe Unit-Sill Picture/Transom/Circle TopTM Unit-SIII Optional Andersen" Optional Andersen" m non-reinforced wood m non-reinforced wood joining material = joining material ti Optional Andersen" N Optional Andersen" E Optional casing g Optional E casing Andersen" o Andersen" o trim strip—mstrim strip— 1/2"(13) 11/16"(43) 1/2"(13) - --- -- -- y 1-11/16"(43) m tiu .2 x x c N N C C � E 0 0 c Double-Hung-Head Picture/Transom-Head Vertical Section Vertical Section 19-12 A R C H I T E C T U R A L D E T A I L F I L E REV.03/05 ;.Andersen® : . - : - •' ;.,WIND-0W.S,.�; D-09 . .-. Tilt-Wash: Do•ub,1- Hu.n,g, Wi.n•dows = ...;;; .;,• Anchoring Methods Jamb Clip Threaded Masonry Fastener / Expansion Sleeve Scale 3" — 1'-0" (1:4) ,' Scale 3" = 1'-0" (1:4) Double-hung window unit secured in opening by others Double-hung window is secured in the opening by removing the weather- using Andersen'302 stainless steel sheet metal jamb strip and drilling through the side jamb into the masonry. clips and stainless steel screws.Bend the jamb clips to secure unit fit in opening.Installation flange can be cut as required to accommodate the jamb clips. APPLICATION: • First secure jamb clip to backside of window unitjamb(s) • Apply 1'from corners of head jamb,sill and side jambs • Space jamb clips evenly(maximum distance apart 32"on center) • Jamb clip lateral design load capacity:maximum 200 Ib. Jamb clip p Threaded fastener (furnished by Score markings for bending others) o �,&_ ® Mffi 3/16" Make sure that the unit frame parts do not become bowed when using (38) (5) anchoring methods.Unit will not operate properly if frame parts are stressed. 3" (76) REV.03/05 A R C H I T E C T U R A L D E T A I L F I L E 19-13 r _ Andersen® - WINDOWS - D0.0RS ® Til.t.-:W.ash D'o.ub:le'=H:ung Windows Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) Remove installation Installation flange at head flange all around Head Head ; m an LA(/6 L = 1/4„ bDLD OC (y) C d C D c oaL. m m au� Jamb Jamb 1/2"(13)* minimum Installation flange all around Sill Sill *1/2"(13)minimum to accommodate differential shrinkage/expansion when brick is used with wood framing. Vertical Section Vertical Section Wood Siding / 2 x 4 Wood Stud Framing Brick Veneer/ 2 x 6" Metal Stud Framing Importance of Proper Installation Proper installation and maintenance ofAndersen*products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12, Head Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different.Andersen strongly recommends consultation with an Andersen product representative and with L an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. tin = 1/4" a ° = Installation of Andersen products,including method of attachment,fastener selection,and code compliance is s (6) = the sole responsibility of the architect,building owner,contractor,and/or consumer. N a E E is E L b o Construction by Others , - In ? 3 I 3 o Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units.Proper integration of the Andersen units with the Jamb weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S.wall finish is adjacent to window units,contact E.I.F.S.manufacturer for installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealant joint around the perimeter of the window. Membrane Installation g ° flashing over NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. flange all installation Installation flange may be removed where construction sequence/detailing requires no flange. around flange (by others) Sill Vertical Section E.I.F.S. / Concrete Masonry Unit (CMU) 19-14 A R C H I T E C T U R A L D E T A I L F I L E R E V.0 3/0 5 Andersen WIRDOW.S.- D( ® Ti,lt-W'a.sh.'b-o.u-ble=Huing, Wind.o:ws Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) Optional ® '® Optional Existing Optional Andersen® Andersen' frame wall Andersen auxiliary vinyl trim auxiliary casing board casing Installation --- flange -- - at head and jambs Head Head Head u on tin m m 1/4„ v° = 1/4„ _ Xm o \\ c _1— m o (6) c EL un m E F////V 7p E 0 0 o-B -- nom_ m EL _ __ b L 0 'c�+ t3 m 0- , M E Jamb Jamb Jamb I t � I ' Installation Remove Installation flange installation all aflanground all around flange at sill Sill SIII Sill Vertical Section Vertical Section Vertical Section Brick/ Concrete Masonry Unit (CMU) Stucco / Concrete Masonry Unit Existing Stud Wall (CMU) Inset Window Optional Existing Andersen' masonry wall vinyl trim board. Trim to fit as required. Importance of Proper Installation Finish trimmed edge with -- Proper installation and maintenance of Andersen'products are essential if optimum performance is to be Optional fully attained.Written installation instructions which provide guidelines for proper installation are available Andersen rigid vinyl Head for Andersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12, channel Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different.Andersen strongly recommends consultation with an Andersen product representative and with m m an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. 1/4" c Installation of Andersen products,including method of attachment,fastener selection,and code compliance is o (6) the sole responsibility of the architect,building owner,contractor,and/or consumer. E ob o is o - gConstruction by Others 3 3 Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units.Proper integration of the Andersen units with the Jamb weather-repellent system of the building is the responsibility of others. NOTE: Where E.LF.S.wall finish is adjacent to window units,contact E.I.F.S.manufacturer for installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealant joint around the perimeter of the window. Installation flange all around NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange. SIII Vertical Section Existing Masonry Wall R E V.0 3/0 5 A R C H I T E C T U R A L D E T A I L F I L E 19-15 . Andersen w N'•D w R ® 'H`' n .e,d, P,a t i,o ,,D o o,r. , • �, ;s.W rn. i. .g s - n g i v#..e �..4lii'.4.�s"S..e§����.�,}�' 'ibvi_:n.yh...:��.?a•�..P}:tl:.)t..ii:.inn"' Contents -. Hinged Patio Doors- Inswing r Basic Unit Details.........................................................26-2 Options/Accessories Accessibility Option................................................26-5 Anderseno Grilles.................................................... 26-6 Extension Jambs....................................................26-7 i Anchoring Methods.......................................................26-8 Joining Details..............................................................26-9 .; Suggested Product Applications..................................26-10 N • 20/10 year limited warranty,fully transferable, non-prorated. • Choose Low-E tempered or Low-E Sun tempered glass. Dual-pane tempered insulating glass is also available. • Smooth,easy operation. • Choose White,Sandtone orTerratone° color exteriors. • White interiors can be painted to match home's decor. REV. 12/O6 A R C H I T E C T U R A L D E T A I L F I L E 26-1 Andersen® wINDOW s •'.D..00Rs ®. Hinged Patio-,,Doors. -- In.swing Basic Unit Details - Single and Two Panel Basic Unit Scale 3" = 1'-0" (1:4) 1-5/16"(33) 4-9/16"(116) 1-5/16"(33) 4-9/16"(116) J 3/4"(19) 9 _ T 5-5/8"+(143+) ti 5-5/8"+(143+) depending on depending on hinge adjustment hinge adjustment L L Head aD Head oD bD m un b0 P C 2 = m ami n m m n o E o o E o E - m E - a� Andersen' Andersen® optional optional gliding 10-3/8"+(264+) hinged 10-3/8"+(264+) insectscreen depending on insect screen depending on hinge adjustment hinge adjustment OO' 1/41"(6) 1/41"(6) U 1-1/4"1( 18) 1-1/4"'T( 18) SIII SIII 6"(152) 6"(152) Vertical Section - with Gliding Insect Screen Vertical Section - with Hinged Insect Screen Two Panel - Active/Stationary or Stationary/Active Single Panel - Active Two Panel - Active/Stationary or Stationary/Active 26-2 A R C H I T E C T U R A L D E T A I L F I L E REV. 12/06 77 %r Andersen. ! .a.N.6 OWS a-D'O.O.,RS H 1 n'g.Q d- :P-,a t i o,,,:-D,o-,o' r-s In s:w i-,n Basic Unit Details - Single and Two Panel Basic Unit scale 3" = 11-0" (1:4) Metro'Collection Tribeca®handle hardware Dual-pane insulating tempered glass 5-5/8"(143) 5-5/8"(143) 3/4"(19) eeS 3/4"(19) Optional hinged insect screen Jamb I go Jamb 1-1/4" Clear Opening Width 1-1/4 (318) (318) Unit Dimension Width 3/8"(10) 3/8u(10) Minimum Rough Opening Width Horizontal Section - with Hinged Insect Screen Single Panel Active Stationary Panel Active Panel 5-5/8"(143) 5-1/8"(130) 5-1/8"(130) 5-5/8"(143) 3/4"(19) 3/4"(19) Astragal Jamb Jamb 50-2-5-5/8"(752) 50=2-5-5/8"(752) 54-21 7-5/811(803) 54=2-7-5/8"(803) 60-2-11-5/811(905) 60=2-11-5/8"(905) Unit Dimension Width 3/8"(10) 3/8"(10) Minimum Rough Opening Width Horizontal Section - with Gilding Insect Screen Two Panel - Stationary/Active (shown) or Active/Stationary R E V. 1 2 0 6 A R C H I T E C T U R A L D E T A I L F I L E 26-3 gte d:, "o" D o,6-r"9*,-'��', :1"n s w.;i�n' g,.,::'- dersen . WI N:Q 0 W S,I D'O 94t S H i,h P"a't' Basic Unit Details - Single and Two Panel Basic Unit scale 3" = 1'-0" (1:4) Door at 901 clear opening position Door at full clear opening position F-I El Ij Mill Jamb Astragal Jamb Clear Opening Width at 90° Clear Opening Width Full Open Position 50=2-5-5/8"(752) 50=2-5-5/8"(752) 54-2-7-5/8"(803) 54=2-7-5/8"(803) 60—2-11-5/8"(905) 60—2'11-5/8"(905) Unit Dimension Width Horizontal Section Stationary / Active 26-4 A R C H I T E C T U R A L D E T A I L F I L E R E V 1 2 0 6 ---------- - Andersen W1NWO,WS6" D00RS., ®. Ki.n.g'ed- Patio.'D.00,'rs- .-, Ins.w.ing ., I ( - Basic Unit Details - Stationary Panel Basic Unit Scale 3" = 1'-0" (1:4) 4-9/16"(116) 1-5/16"(33) 3/4"(19) 5-5/8"(143) 5-5/8"(143) 5-5/8"(143) m u d o. O o — Head � E j E c Jamb 10-3/8"(264) 1-1/4" 1-1/4" (318) Unit Dimension Width (318) Minimum Rough Opening Width Horizontal Section Stationary Panel — 1 Sill 6"(152) Vertical Section Stationary Panel Accessibility Option Scale 3" = V-o" (1:4) Accessible Door A special"accessible door"option is available that offers a 32"clear opening Low threshold sill width at 90°and a 1/2"high threshold. Meets door width and threshold height requirements of ICC/ANSI A-117.1-2003 and ADAAG guidelines.Contact your WLFWd Andersen supplier for availability. Llv= - 1/2"(13) REV. 12/06 A R C H I T E C T U R A L D E T A I L F I L E 26-5 Andersen i WINDOWSDQORS I Hinged Pati°o `:Do,ors Inswing Standard Grille Options / Accessories Contact an Andersen Representative for project specific grille options. 200 Series Grille Options Removable Interior Andersen°Finelighem Grilles Grilles-Between-the-Glass Grille Profiles scale = Full Removable Interior Wood Grille Profiles(chamfer profile). 7/16" Z:� 7/16" 7/16" L LEf:1 L 3/4" 7/8" 1-1/8" Andersen°Finelightn"Grilles-Between-the-Glass 3/8" 1/2" 3/4" 1" Window Profile Patio Door Profile 26-6 A R C H I T E C T U R A L D E T A I L F I L E AEV. 12(06 Andersen .WlnrooWs.• DO1 Rs Hin ed Pati=o•-_Doors Inswi:n g - g Options / Accessories Prefinished White Interior Extension Jambs Scale 3" - 1'-0" (1:4) 11/16"(17) -------------- ----------------- -- 070 7 U U lL a 7-1/8"(181) 6-9/16"(167) 5-1/4"(133) Extension jamb Extension jamb Extension jamb 4-9/16"(116) Interior extension jambs have a low-maintenance white finish 1-5/16"(33) and are available for 5-1/4"(133),6-9/16"(167),and 7-1/8"(181)wall thickness.Other wall dimensions can be accommodated with extension jamb modification.Extension Unit Dimension Width jambs are pre-drilled for easy application. Rough Opening Width Width Horizontal Section Interior Extension Jambs:The use of Full panel ��� interior extension operation O jambs will restrict Installed flush Restricted panel panel operation on to interior wall—? operation jamb hinged doors. Jamb hinged patio Optional Andersen° doors must be extension jambs installed flush to the interior to achieve full Exteriortrim and i 1-3/4"(44) panel operation. flashing by others– Jamb hinged patio door in 2 x 6 wall Jamb hinged patio door In 2 x 6 without extension Jambs wall with extension Jambs REV. 1 2/0 6 ARCH ITECTU RAL D E T A I L F I L E 26-7 Andersen l j, WINDOWS.• D.O.o.:RS ® Hinge„d Patio -D6bo s - I,n�swing_ Anchoring Methods scale 3” = V-0° (1:4) Wood Screw Fastener/Flange in Standard Position Wood Screw Fastener/Flange in Reversed Position Patio door unit is secured in opening using wood screw fasteners through the jamb Patio door unit is secured in opening using wood screw fasteners through the (the flange itself cannot support the door). jamb(the flange itself cannot support the door). Wood screwa�sa�— mo r fastener s '' Wood screw fastener co m 0 o io C m m fir. � _ •—_. Exterior sheathing it Flange Flange in reverse position 01 Threaded Masonry Fastener / Expansion Sleeve Make sure that the unit frame parts do not become bowed when using anchoring methods.Unit will not Patio door unit is secured in opening by pre-drilling through side jamb into masonry operate properly if frame parts are stressed. Threaded masonry fastener � ro O , .. Flange removed 26-8 A R C H I T E C T U R A L D E T A I L F I L E REv. 1206 Andersen W I N D'd W S � D.o.o WS:1 H;i n geed;.,R,:aai,'o :D.'o`0:rs:; Joining Details Andersen® Joining Materials Scale 3" = 1'-0" (1:4) Joining Compatibility Many Andersen®units are designed to be joined with other Active Panel Stationary Panel Andersen units in a variety of non-reinforced and reinforced 3/4"(19) 2 (51) 3/4"(19) combinations.Other combination types and joining methods can be viewed in the Andersen®Product Guide for Professionals, Interior trim and in Andersen Window Studio®software,and by visiting extension jambs by others andersenwindows.com.Combination designs should always be I structure by others checked for design pressure performance requirements to make I sure the appropriate joining method is specified. I I I I I I I i Optional Andes2"(51)en® �Optional Andersen 2"support 2"support mullion mullion trim strip set in continuous wood filler bead of sealant each side 2" Support Mullion Frenchwood®Patio Door Transom L O WI 2 O Active Panel Stationary Panel Ande seln® E 3/4"(19) reinforced LVL o 3/4"(19) 3/4"(19) joining strip Optional Andersen° 1"(25) Al wood casing 3/4"(19) 3/4"(19) 3/4"(19) Trim strip set El n continuous bead of sealant each side = 0 E 0 Trim strip set in continuous �--� Optional Andersen® bead of sealant each side 3/4"(19) reinforced LVL joining strip Inswing Patio Door Andersen® LVL Reinforced Mullion Andersen® LVL Reinforced Transom REV. 1z/os A R C H I T E C T U R A L D E T A I L F I L E 26-9 Andersen:1,!S!D 0,W,$'• D 6`0 R'S- 'h ge:d :P:' a t-i o, D 0U„ s n s WVn Suggested Product Applications Wall Types Scale 1-1/2” = V-0" (1:8) Remove flange at head and Flange at head iambs and iambs Optional Andersen* PW- -A insect screen Head Head JL� 3/8" 3/8" (10) (10) 15 :S9 t UCL :Q9 EL O :2 C-: .2 0 E .E E E E z,.e Jamb Jamb Optional Andersen® insect screen eg Sill Sill Vertical Section Vertical Section Wood Siding / 2 x 4 Wood Stud Framing Brick Veneer/ 2 x 6 Metal Stud Framing Minimum Rough Opening Rough opening dimensions shown are the minimum dimensions recommended for proper installation.These dimensions may need to be increased to allow for use of building wraps, flashing,sill or pan flashing,brackets,fasteners or other items which could decrease these dimensions.Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer. Importance of Proper Installation Proper installation and maintenance of Andersen products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12,Bayport,IVIN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. Construction by Others Andersen corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units. NOTE:Where EIES.wall finish is adjacent to units,contact E.I.F.S.manufacturer for installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width ofsealantloint around the perimeter of the unit. NOTE:Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.Flange may he removed where construction sequence/detailing requires no range. 26-10 A R C H I T E C T U R A L D E T A I L F I L E R E V. 1 2/0 6 ::Andersen iw1No0ws • o,o0 s.,® ,Hi,n ed 'P"ati.o. .Doors - :1n'swlri { g 9 J Suggested Product Applications Wall Types Flange at head 8 and jambs Fxtedor trim by others U Optional Andersen' insect screen Membrane Head flashing over Head flange(by others) a. 3/8,. 3/8„ (10) (10) _ — nn t co � ti0 .E a C E o Er .1 E ¢ E a .E E E Jamb Jamb Optional s; 6 Andersen® insect ' screen . 10 SIII SIII Vertical Section Vertical Section E.I.F.S. / Concrete Masonry Unit (CMU) Brick/ Concrete Masonry Unit (CMU) Minimum Rough Opening Rough opening dimensions shown are the minimum dimensions recommended for proper installation.These dimensions may need to be increased to allow for use of building wraps, flashing,sill or pan flashing,brackets,fasteners or other items which could decrease these dimensions.Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer. Importance of Proper Installation Proper installation and maintenance ofAndersen'products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available forAndersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12,Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. Construction by Others Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units. NOTE:Where E LF&wall finish is adjacent to units,contact E.I.F.S.manufacturer for Installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealantjoint around the ped meter of the unit. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.Flange may be removed where construction sequence/detailing requires no flange. R E V. 1 2/0 6 ARC H ITECTILIRA L D E T A I L F I L E 26-11 E Andersen® W.UNDgVs -Wo o'R_s,® H:i;nged Pat_Io.,:R:o;ors . lbsWing. ._ Suggested Product Applications Wall Types Scale 1-1/2" = V-0" (1:8) Exterior trim by others Exterior trim Existing by others frame wall 1-3/16"(30) Flange at head ; Flange at head and jambs and jambs P; Head Head 3/8" Exterior trim 3/8" (10) by others (10) m t — x x m � m S9 tin a c n ti 0 0 o m 0 0 o E E E � E C C •C C "c' Jamb Jamb >> Optional Optional Andersen' ® insect insect screen screen a a o . " o 0 Sill sill Vertical Section Vertical Section Stucco / Concrete Masonry Unit (CMU) Inset Door Existing Wall Minimum Rough Opening Rough opening dimensions shown are the minimum dimensions recommended for proper installation.These dimensions may need to be increased to allow for use of building wraps, flashing,sill or pan flashing,brackets,fasteners or other items which could decrease these dimensions.Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer. Importance of Proper Installation Proper installation and maintenance of Andersen`products are essential if optimum performance is to be fully attained.Written installation instructions which provide guidelines for proper installation are available forAndersen products from your local Andersen supplier or by writing to:Andersen Windows,Inc.,Box 12,Bayport,MN 55003 or by visiting our website at www.andersenwindows.com.Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor,architect,or structural engineer prior to the installation of any Andersen product. Construction by Others Andersen Corporation is not responsible for the design of,conditions in,or performance of,adjacent wall or roof construction beyond the perimeter of the Andersen units. NOTE:Where E LF..S.wall finish is adjacent to units,contact E.I.F.S.manufacturer for installation instructions,including the use of appropriate flashing,the proper use of sealant and backer rod,and the proper width of sealant joint around the perimeter of the unit. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework.Flange may be removed where construction sequence/detailing requires no Flange. 26-12 A R C H I T E C T U R A L D E T A I L F I L E REv.12/os