Loading...
HomeMy WebLinkAbout49514-Z FBI/( Town of Southold 9/1/2023 a P.O.Box 1179 oC* ` !� 53095 Main Rd P Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44519 Date: 9/1/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 330 Maple Ln, Orient SCTM#: 473889 Sec/Block/Lot: 17.-3-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/24/2023 pursuant to which Building Permit No. 49514 dated 7/25/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Yuskavage,Lisa&Levenstein,Matvey of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49514 8/22/2023 PLUMBERS CERTIFICATION DATED �uth&zed Signatu I, ' TOWN OF SOUTHOLD BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE "oy • o� l SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49514 Date: 7/25/2023 Permission is hereby granted to: Yuskavage, Lisa 438 E 12th St 5M New York, NY 10009 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 330 Maple Ln, Orient SCTM #473889 Sec/Block/Lot# 17.-3-2 Pursuant to application dated 7/24/2023 and approved by the Building Inspector. To expire on 1/2312025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $200.00 Building Inspector pF SO�lyol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 a sean.devlin(cD-town.southold.ny.us Southold,NY 11971-0959 olyIrou BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Lisa Yuskavage Address: 330 Maple Ln city:Orient st: NY zip: 11957 Building Permit#: 48606&49514 Section: 17 Block: 3 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy LLC License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Battery Storage New X Renovation 2nd Floor Pool House X Addition Survey X Attic Main House X INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 22.4kW Roof Mounted PV Solar Energy System w/ (38) Qcellgpeak400WPV Module: on House and (18) Qcellgpeak400W Modules on Pool House 30A Disconnect, 60A Disconnect Notes: Solar on House & Pool House Inspector Signature: ate: August 22, 2023 S.Devlin-Cert Electrical Compliance Form pF SOUIyo`o TOWN OF SOUTHOLD BUILDING DEPT. �0 • �O `ycouff 631-765-1802 �51 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING FRAMING-/-STRAPPING-- FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: so DATE INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS \J\ rn FOUNDATION (IST) --------------------------------------- - FOUNDATION (2ND) cn ROUGH FRAMING& y 1 PLUMBING INSULATION PER N. Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS Lo -t-20-477 ' 0 FO o�osui L4,eo TOWN OF SOUTHOLD —BUILDING DEPART ENT ca ac Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 oy��� �ao� Telephone (631) 765-1802 Fax(631) 765-9502 https://www.Souiholdtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: JUL 2 4 Pon `Applications and,forms must be filled out in their entirety.Incomplete applications will not be accepted.-Where the Applicant is not the owner,an. BUILDING DEPT. Owner's Authorization form(Page 2)shall be completed. TO`, "'1'F01 73, Date:7/21/23 OWNER(S) OF PROPERTY: { Name:Lisa Yuskavage SCTM# 1000-01 7.00.�03.01011-010112.000 Project Address:330 Maple Lane, Orient NY 11957 Phone#:631-779-7993 FE_mai�kpermits@De2sys.com Mailing Address:330 Maple Lane, Orient NY 11957 CONTACT PERSON: Name: Lorraine E. DiPenta Mailing Address:7470 Sound Ave, Mattituck, NY 11952 Phone#: Email:permltS9e2syS.COm DESIGN PROFESSIONAL INFORMATION: Name:N/A Mailing Address:N/A Phone#:N/A Email:N/A CONTRACTOR INFORMATION: Name:Element Energy"LLC Mailing Address:7470 Sound Ave, Mattituck, NY 11952 Phone#:631-779-7993 FEmail:permits@e2sys,.Com " DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑� Other Existin use suiar pv system,BP#48606 has been issued for house PV system,cost is total of 2 structures $79,968.00 Will the lot be re-grade ? ❑Yes ©No Will excess fill be removed from premises? ❑Yes ®No 1 li PROPERTY INFORMATION Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Residential this property? ❑Yes ON IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage aind storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone .Ordinance of the Town of Southold,Suffolk,County,New York.and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. (�I L44ASL- LA"�.I rr � Application Submitted By(print name)-— BAuthorized Agent ❑Owner Signature of Applicant: �M�������Date: 7/21/23 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Lorraine E. D i Penta being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)heisthe Contractor/ Agent (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the saidwork and to make and file this application;that all statements contained in this application are true to the best of hisher knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of \ kA- , 20 VS LOUIS J ROME otary Public Notary Public,State of New York No.01 806314813 Qualified in Suffolk County Commission Expires November 17,2QXPROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Lisa Yuskavag a residing at 330 Maple Lane, Orient, NY 11957 I, Lorraine E. DiPenta/ ElementEnergy LLC do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. 07/21 /23 Owner's Signature Date Lisa Yuskavage Print Owner's Name 2 {�S�fF�j�-{'` rt BUILD - ING DEPARTMENT- Electrical Inspector ti SG r TOWN OF SOUTOOLD y< , Town Hall Annex - 54375 Main Road - PO Box 1179 >;y ►x Southold, New York 11971-0959 y 01 - Telephone (631) 765-1802 - FAX (631) 765-9502 -0" rogerrCaDsoutholdtownny qov seaddCaD-southoldtownn .qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date. Company Name: ;� C!?,f Electrician's Name: 0; It License No.: EIec. email: (2 S S' 49M Elec. Phone No: `p . 1 request an email copy of Certificate of Compliance Elec. Address.: Q DU e _ 111S� i JOB SITE INFORMATION (All Information Required) Name: Address: Cross Street: Phone No.: 9 7- 051) On -1)we ;f1 Bldg.Permit #: �vl �j��( email: Tax Map District: 1000 Section: (�� Block: Lot: ®v �nq BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size®1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New service[—]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground[]Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: I PAYMENT DUE,WITH APPLICATION SURVEY OF PROPERTY N 51'FUATEe ORIENT TOMwFr- 5 coLN LD 5UIT'OLK COUNTY,NY W E C tINK2TAX 0M 0 E-_MC*ff EOF-WAY)E--______E�JC1NE E J k7O?fl-b2 JL-,W------------------- a•�------ •...� $x°59'40'$ � ��v--------------- - �n�zQ - --------------------- --- --- 2 STORY -- -� I �w.+..w rwu •' FRAME LAfmR EW=m Y Q HO1155EVNELLINS td I i lu F WELL 150' I POOL Y ..............'..............._....-.__._: Test Hole , MGDcmId GaosUence 1 -M PRAMj •C• \ \ / A ■' LAND NOW OR FOG¢RLY OF POPMANAFFY \ ' VACANT \ __\ / ST YK •w �� \ O POS a'� \HORSE\ O / a•= V � � s• _�s____ \ T PROP05Wrp - :,•�. / SEPTIC 5Y5TEM Nom c HONR1fTIf FaDNO BIIBDATA: wWAM s� Q PIPE Fain 140' •:�' �•� IIIC DffLLING • POST FO ^S:J�^i�."?a•• WELL AREA. 46.W6 5F OP.1,06 ACRES WELL >� JOHN C.EHLEA LAND SURVEYOR `O' 6 EA8•CMAtt1 SIRFEf N.Y.B.IdC NO.502D2 6RAPHIG SCALE I'=W. RIVBR�AD,N.Y-1. -- _ 369-8288F=369-8287 AFF,\WAmpngwve 1D1101-1564iro — i '4`� CERTIFICATE OF LIABILITY INSURANCE DATE(M 7/M 1'°°/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW_ THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terns and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER ICONTACT ROBERT S. FEDE INSURANCE AGENCY PH40NE - FAX - 23 GREEN STREET,SUITE 102 E MAN°ExtI.- AIC No HUNTINGTON,NY 11743 ADDRESS: W� ROBERTS.FEDE INSURANCE INSu AFFORDING COVERAGE NAIC 0 INSURER A:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURERB:,9TATE INSURANCE FUND 523930 Element Energy LLC INSURER DBA ELEMENT ENERGY SYSTEMS URER0. U GENERAL STAR MANAGEMFENT Go. —37362-- 7470 SOUND AVENUE INSURER E: MATTITUCK,NY 11952 ENSURER F: i COVERAGES CERTIFICATE NUMBER: REVISION NUMBER- TH1S IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCEADCLSUBR POLICY EFF POLICY EXP LTR POLICY NUMBER MMIDD LIMITS COMMERCIAL GENERAL LIABILITY L1460036873 EACH OCCURRENCE s 3,000,000 A X X 7/1412023 7/1412024 CLAIMS MADE ®OCCUR PREMISES 4E2 aarurrenae $ 100,000 MEM Exp I .P...) s 5000 x Contractual Lia 1MA3892038 7/19/2022 7/19/2024 pERSONAL&AOV INJURY s 3000000 GEML AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 3,000,000 POLICY KI EC F_I LOC PRODUCTS-COMPIOPAGG 3 OTHER: S AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT : Ea accident ANY AUTO BODILY INJURY(Pet person) i OWNED SCHEDULED BODILY INJURY(Per acriden AUTOS ONLY AUTOS : HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY par,a�'ident $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS UAB HCLAKMS-MADE AGGREGATE $ DED RETENTICN$ $ WORKERS COMPENSATION 124494445PERq ERS AND EMPLOYERS'LIABILITY Y J N 7/13/2023 7113/2024 NT' ANY PROPRIETORMARTNEWEXECUTNE E.L EACH ACCIDES 1,000,000 $ OFFICERlb1EMBER E(CLUDED? Ix I N I A (Mandatory in NN) EL(DISEASE-EA EMPLOYE S 1-OW 000 It yes,deSOdbe Under DESCRIPTION OF OPERATIONS below EL(DISEASE-PONY LIMIT f I non Min NY State DBL DBL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS r VEHICLES rACORO 101,Add0lonal Remarks Schedule,maybe attached K more space Is required) i CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. i AUTHORIZIED REPRESENTATWE Ra ►'tS. Fede ©1988-2015 ACORD,CORPORATION. All rights reserved. Arnon is nn-iArnt► Thr Ar nOn......,. ,...L 1.... .. ..n:sM.wwl—1— i Arnorn I NYSIF New York State Insurance Find PO Box 66699,Albany,NY 12206 j nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) Q A A A A A A 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 O HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER i ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTffUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 369075 07/13/2023 TO 0711312x24 7111/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/1WWW.NYSIF.COMICEIjT10ERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIFi AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED ASA MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT ',AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU CE FUND DIRECTOR,IIiNSURANCE FUND UNDERWRITING Y Workers' rj STATE Compensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured fonlyruquired ifcoverage is speallcallyAmited to certain locations in New York State,i.e.,Wrap Up Policy) 32333660 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Uste4in Box"ta" SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/01/2023 to 12/3112024 4. Policy provides the following benefits: ® A-Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or ctasses of employers employees: Under penalty of pequry,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/14/2023 By U41� (signature of insurance carrier's authorized representative or NYS Licensed imrance Agent oftfw insurance carrier) Telephone Number 516-329-8100 Name and Title Richard White, Chief EXecutive Officer IMPORTANT: If Boxes 4A and SA are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only If Box 49,4C or 56 have been checked} State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurancepolicies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-920.1.Insurance brokers are NOT authorized to issue this form. Da"iao.i (ia-ai) Zoho Sign Document ID:M2UVBXDBWH-1-61ULIB4H_YKJHR5Y9K5ulY6VLD_D40 i Town of Southold September 28th, 2022 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Yuskavage Residence, 330 Maple Ln, Orient, NY 11957 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also, the wind analysis concluded that the mounting system las shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.9 pounds per square foot.. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. SOF NE1 1V Great Eastern Services, Inc. CO g0 Ai PO Box 240 24 Harvey Rd - '' u, Riverhead, NY 11901 m w Office: 631.543.9555 AR�103��344NPS Mobile: 631.235.0189 Email: jerrygiustra@gmail.com I j\ powered by Ca f • �„ � YR 1 TOP BRANQ PV. tiYM:Nii� ' Warranty 2021 O CELLS w°a,ct&P.k rorce Yield Security BREAKING THE 20%EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20 .9%. 1 THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- Q sive quality programme in the industry:The new"Quality Controlled PV"of v� the independent certification institute TOV Rheinland. „� INNOVATIVE ALL-WEATHER TECHNOLOGY C—J�: Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID \ Technology',Hot-Spot Protect and Traceable Quality TraMm. EXTREME WEATHER RATING High-tech aluminum alloy frame,'certified for high snow(5400 Pa)and wind loads(4000 Pa). 20 A RELIABLE INVESTMENT � � Inclusive 25-year product warranty and 25-year linear performance warrantyz. I AFT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) 7 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: (10 Rooftop arrays residential buildings I Engineered in Germany OCELLS i ' MECHANICAL SPECIFICATION d Format 74.Oinx4llinx125inpncludingframe) (1879mmx1045mmx32mm) 74,r eremm) lar(nss-) axe•tmeemm) Weight 48.5lbs(22.0kg) Front Cover 0.131n(3.2mm)thermally pre-stressed glass with anti-reflection technology a.omuwnava'maaoae•faemm) r.no Back Cover Composite film ssslsae n s Frame Black anodized aluminum Cell 6 x 22 monocrystalline G.ANTUM solar half cells ® aLraoae-) Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.711n (53-101mm x 32-60mm x 16-18mm),I1367,with bypass diodes :aaz I>zcdmm) Cable 4mmzSolar cable;(+ja49.21n(1250mm),(-)149.2in(1250mm) -� a.od..00eda 3 a.Nwrtneraeloewta d Connector Stdubli MC4;IP68 OEM oArfse I yYg•137,� I-� 096'f2abmm)I_Io-1a•(aamm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-OW) Power at MPP' PMW [W] 385 390 1395 400 405 E Short Circuit Current' Is, [A] 11.04 11.07 11.].0 1114 11.17 Open Circuit Voltage' Voc [V] 45.19 45.23 45.27 45.30 45.34 ,2 Current at MPP IMaa [A] 10.59 10.55 10.71 10,77 10.83 Voltage et MPP VMPP [V] 36.36 36.62 38.88 3713 37.39 Efficiency' 11 [%] 119.6 119.9 a!kl 120.4 220.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PMPP [W] 288.8 292.6 296.3 3001 303.8 2 Short Circuit Current Isc [Al 8.90 8.92 8.95 8.97 9.00 Open Circuit Voltage Voc [V] 42.62 42.65 42.69 4272 42.76 Current at MPP IM [A] 8.35 8.41 8.46 8.51 8.57 l Voltage at MPP VMPP [V] 34.59 34.81 35.03 35.25 35.46, 'Measurement tolerances Pum t3%;Isc;Voc±5%at STC:1000 W/e,25±21C.AM 1.5 according to IEC 60904-3•'800 W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE r roo ocaL E.10 --r-----r-----r'----h-----• 0 8 u _.a". ��.�.�r At least 98%of nominal power during u �15 first year.Thereafter max.0.5% 9 oe ------------------- degradation per year.At least 93.5% ----- ------- Wof nominal power up to 10 years.At z i least 86%of nominal power up to ; w -------------- ------ a c 25y@ars. eo --r-----r-----r---- ----- z u All data within measurement toleranc- 3 ■ ------------------------- eo a: es.Full warranties(n accordance with mo aoo coo too ,000 ui a ftre warranty terms of the Q CELLS c f IRRADIANCELW.-I ® sales organisation of your respective c a o rP >e m m country. 9.e.a,om,aO,r.wmnmiowemp,m VMS Typical module performance under low irradiance conditions In o comparison to STC conditions(25°C,1000 W/m2) 1 m TEMPERATURE COEFFICIENTS o Temperature Coefficient of Ise a [%/K] +0.04 Temperature Coefficient of Voc p [%/K] -0.27 Temperature Coefficient of PMPP y [%/K] -0.34 Nominal Module Operating Temperature NMOT ['F] 109±5.4(43±3°C) m 0 PROPERTIES FOR SYSTEM DESIGN u Maximum System Voltage V- [V] 1000(IEC)/1000(UL) PV module classification Class II Rarq Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 1 TYPE 2 W Max.Design Load,Push/Pull' Obs/ft°] 75(360OPa)/55(2650Pa) Permitted Module Temperature -40°Fupto+185"F o Max.Test Load,Push/Pu113 Obs/ft2] 1.13(5400 Pa)/84(4000Pa) on Continuous Duty (-40°C up to+85°C) 9 'See Installation Manuel u QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION a UL81730,CE-comphant, I�'irn IEC6yControlled C-70VRh-4end, of-O') <C'HCI a IECBatent2018•I938173(}2018, ♦ ♦ w U.S.Patent Na 9,893,215(solar cells), r` (`�, ,m�a�+.e Horizontal 76.4 In 43.3in 48.Oin 16561bs 24 24 32 a GGPV Certification ongoing. Cc�,,,b US packaging 1940mm SSOOmm 1220 mm 751kg pallets pallets modules .0 VL . •wtuvm0 a m tima®i N I Note:Installation instructions must be followed.See the Installation and operating manual or contact our technical service department for further Information on approved installation and use of this product. Henwha 0 CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 69 96 1 EMAIL W inquiry@us.q-celis.com I EB www.q-cells1.US i I I i EN PHASE. I m m I I i IQ8 and IQ8+ Microinverters Easy t9install Our newest lQ8 Microinverters are the industry's first micragrid-forming,software- =lightweight and.bompact with' defined microinverters with split-phase power conversion capability to convert DC plugan-play conn-eetors. power to AC power efficiently.The brain of the semiconductor-based microinverter : power Line Communication' is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times = Faster installation withsimple to changing loads and grid events,alleviating constraints an batterystzing•far home i ivo-wire caf*ling energy systems. High.productivity ,and rellability Produce power even when the IEnphase grid is down* - (More than one million cumulative hours of testing year limited - Cla§s If double-insulated' Par toftheEnphasoEnergySystem,108Series 108 Series AfficroinvertersredeRnereliability enclosure Mcroinvertersintegrate with the Enphase IQBattery, standards with more than one million cumulative . Optimized-for the-litist high- Enphase IQ Gateway,and the Enphase App monitoring hours ofpower-on testing,enabling anindustry- and analysis software. leading limited warranty of up to 25 years. P Micro grid-forming - Complies with the latest = ;advanced grid support=' CERTIFIED SAFETY = Remote automatic updates for = the latest grid requirements Connect PV modules quickly and easilyto 108•Series I08 Series Microinverters are UL Listed as • 'Configurable to supporta wide•• Microinverters using the Included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when Installed according to range'ofgrid•profiles manufacturersinshuctlons •;Meets CA Rule 21(UL 1741-SA) 'requirements 0 2022 Enphase EneW All rights reserved Enphas%the Enphase logo,108 Mlcrcinverters,and other •Only when installed with 10 System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. '•IQ8 and 108PIus supports split phase,240V IOSSP-DS-0002-01-EN-US=2022-03 17 installations only i i I I a JQ8 and IQ8+ Microinverters INPUT DATA 10C) 198-60-2-US Commonly used module pairings' IN 235-350 235-440 60-cell/120 half-cell,66-cell/132 half-cell and 72-ceIV144 Module compatibility 60-cell/120 half-cell half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 ! Min/max start voltage V• .30/48 30/58 Max input DC voltage V 50 60 i Max DC currentz[module Iscl A. 15 Overvoltage class DC port II DC port backfeed current MA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) ,: ,0 ,.. Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/ranges V 240/211-264 ! Max continuous output current A 1.0 1,21 Nominal frequency NZ 60 Extended frequency range Nz 50-68 AC short circuit fault current over 3 Aims ' 2 cycles Max units per 20 A(L-L)branch circuit° 16 13 Total harmonic distortion <5% Overvoltage class AC port 111 AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 I Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -400C to+600C(-40OF to+140°F) Relative humidity range 4%to 100%(condensing) DC Conneotortype• MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-5A),UL 62109-1,UL1741/IEEE1547,FCC Part15 Class B,ICES-0003 Class B,CAN/CSA-C222 NO.107.1-07 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 69012 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when Installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current Is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area I IQ8SP-DS-0002-01-EN-US-2022-03-17 I I ®� IRON RIDGE FlusIh Mount System I I I I Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails!and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. I Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design(Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year, Warranty ® Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. Ali XR Fiails O I XR10 Rail XR100 Rail XR1000 Rail Bonded Splices 71 A low-profile mounting rail The ultimate residential A heavyweight mounting' All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capabilityi Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability Varying versions for rails • Clear and black finish • Clear and black finish - Clear anodized finish Forms secure bonding Clamps &Grounding O i UFOs Stopper Sleeves Grounding Lugs Microinverter Kits I -M i Universal Fastening Objects Snap onto the UFO to tum Connect arrays to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. j Rails. • Fully assembled &lubed - 'Bonds modules to rails - Low profile • Bonds devices to rails • Single,universal size • Sized to match modules - Single tool installation - Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 I Attachments O i FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware I Flash and mount XR Rails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XR Rails with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. • Twist-on Cap eases install - Twist-on Cap eases install - Secure rail connections • T&Square Bolt options • Wind-driven rain tested • Wind-driven rain tested - Slot for vertical adjusting • Nut uses 7/16"socket • Mill and black finish • Secures 9/a"or 1"conduit - Clear and black finish • Assembled and lubricated Resources Design Assistant NABCEP Certified Training -_ --— - NABCEP Go from rough layout to fully Earn free continuing education credits, _ � _- engineered system. For free. / while learning more about our systems. �: Go to IronRidge.com/design Go to IronRidge.com/training I .._ ... - .. ... . . _ . . .. .. ���® Zoho Sign Document ID:M2UVBXDBWH-I-6IULIB4H_YKJHR5Y9K5QIY6VLD_D40 SCOPE OF WORK C N�^£�,�OR DESIGN B DRAFTING BY: ELEMENT ENERGY LLC [TO INSTALL A 22.4 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE YUKSAVAGE RESIDENCE, REVIEW BY J.M.NABCEP CERTIFIE LOCATED AT 330 MAPLE LN,ORIENT, NY 1 1957. 051112-129 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID cON�y�CS�Gtf� THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS DE5CRIFTION DATE REV SYSTEMRATING °Isla ORIGINAL 09-27-2022 22.4 kW DC STC _- Fan Mahon EQUIPMENT SUMMARY 5G QCELL Q.PEAK DUO BLK ML-G 10+400 WATT PV MODULESa°^ 5G ENPHASE IQBPLU5-72-2-U5 MICRO INVERTERS CONTRACTOR sunt Isla O Ms � I IRONRIDGE XRI 00 MOUNTING SYSTEM West±4 SKEET INDEX 5* Pv-1 COVER Shelter island ELEMENT ENERGY, LLC. OF HEV(/ ELEC 7470 SOUND AVE PROJECT LOCATION PV-3-4 ROOF PV LAYOUT P��—� A-�`- — — — MATTITUCK, NY 1 1 95 o INSPEC'TiON-REQUIRED— _ PV-5 STRUCTURAL/DETAILS#SECTIONS pg G/G 'Q LICENSE# G74G1=H( PV-G 3-LINE ELECTRICAL DIAGRAM ?`� Sj LICENSE # 52689-ME PV-7 LABELS N GOVERNING CODES m z o° _ - tiN 2017 NATIONAL ELECTRICAL CODE. 2020 RESIDENTIAL CODE OF NEW YORK STATE. SOA 3443 ' PROJECT NAME 2020 FIRE CODE OF NEW YORK STATE. R�FESSIONP� W 270°� 090°E y ASCE 7-1 G AND NFPA-70. UNDERWRITERS LABORATORIES(UL)STANDARDS 240° 120° Lu U OSHA 29 CFR 1910.2G9 GENERAL NOTES 210180150° o z m S - Q 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT cn J THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE lL! Lu HIMSELF WITH INTENT OF AGREE THE SAMETHESE PLANS AND MAKE WORK AERIAL VIEW tli 11- Z 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED Q APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVA T Q INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM z CONTRACTOR'S LIABILITYF, If REQUIRED , WORKMAN'S COMPENSATION, ALL LU 3. ALL WORK SHALL CONFORM TO CONSAGENCIES HAVING JURISDICTION OTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES OF Q m - OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO NEW YORK STATE $t TOWN COD I/ ALL RULES AND REGULATIONS OF THE RESPONSIBLE S m JURISDICTION. COMMENCING WITH WORK. AS REQUIRED AND CONDITIONS F O J I D THE COURSE OF CONSTRUCTION A CONDITION EXISTS 1 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE AP ROVED AS NOTED THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND DATE:. g:p:: � 'fg �NQ CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT NNING BOA D RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, FEE:.: ld� _ By:. .._., �� �WN�RUSTEES OTISHEET NAME SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY � - 5. ALL STRUCTURAL STEEL SHALL BE A-BG AND SHALL BE NFY:`BUILDING DEPARTMENT AT FABRICATED AND INSTALLED AS PER SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT LATEST A.I.S.0 CONSTRUCTION. 768=1$02 :8 AM TO A PM`>FOR THE COVER SPECIFICATIONS. 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE FOLLOWING:INSPECTIONS!", G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. t 1• FOUNDATION-- TWO REOUIRED CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING iOR NYS CODES REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND FOR POURED'CONCRETE':. OCCUPANCY 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. 2• ROUGH'- FRAMING & ._PLUMBING f '^� '� �� DRAWING SCALE CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS 3: INSULATION UV` LAWFUL CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ONINAL: ri V^( •�. . 8. THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. 4• F .'-:.CONSTRUCTION MUST ' SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK,THE SITE TO BE CLEARED BE COMPLETE FOR C.O. NITNOUT CERTIFICAT PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE ALL C THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BONSTRUCTION SHALL MEET THE )F OCCUPANCY SHEET NUMBER E COMPLETED TO THE REQUIREMENTS OF THE CODES OF NEW EXTENSIONS TO THIS PR TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. YORK STATE. NOT RESPONSIBLE FOR PV_ EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS DESIGN OR CONSTRUCTibN RESULT OF HIS WORK. ' TAX MAP: 1000-0 17.00-03.00-002.000 Zoho Sign Document ID:M2UVBXDBWH-1-61ULIB4H_YKJHR5Y9K5QIY6VLD_D40 LEGEND DESIGN 4 DRAFTING BY: MISTING UTILITY METER REVIEW BELEMENT NABC P CERTIFIE MAIN SERVICE PANEL NEW PV SUB-PANELS 051 1 12-120 A/C DISCONNECT - q• COMBINER INVERTERS e GNOELECTRODE REVISIONS DE5CRIPTI0N DATE REV PV MODULE ORIGINAL 09-27-2022 RACKING RAIL O ATTACHMENTPOINT ---RAFTERS F ROOF PITCH ANGLE EISUNRUN METER ®VENT OPLUMBING VENT 7: ®SKY LIGHT I I' 6' I ' CONTRACTOR ®CHIMNEY COMPOSITE SHINGLES GOOD CONDITION I �l POTENTIAL SHADING ISSUES 12'-23 J 12'-3'� 12'-3" u TR(M/REMOVE AS NECESSARY 4" ELEMENT ENERGY, LLC. 7470 SOUND AVE --- - -- --- ----- - -- ------ ---- -- ------ ----- - -- - - -- - - -- -- - MATTITUCK, NY 11952 --- ---- - - -- - ---- - -- -- - - -- - - -LICENSE #67461-H1 -- ------ LICENSE# 52G89-ME PROJECT NAME LU LU Lu Ln I) Q VmJ L.L � LL1 Q z Q > C) W_ E/ � m0 "--------- POOL HOU5E of: NEtV SHEET NAME O OTHE ROOF SETBACK/PATHWAY � ACK/PATHWAY SHALL NOT BE P� O A 1.) i9j�� N SITE PLAN REQUIRED TO DETACHED GARAGE IN 0° ACCORDANCE WITH R324.G EXCEPTION OF 33-B4 I 2020 NYS FIRE CODE 2.)THE ROOF SETBACK/PATHWAY SHALL NOT BE � N �.-� W27 DRAWING SCALE ° REQUIRED TO ROOF5 WITH SLOPES OF TWO �O 103443 = 0 a ° UNITS VERTICAL IN 12 UNITS HORIZONTAL OR LESS IN ACCORDANCE WITH R324.G.I 'ARD SS1240° D 1290 E 5/25611 = 1-011 EXCEPTION OF 2020 NYS FIRE CODE 210° 0° 50° CONSTRUCTION NOTES 180° 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE S SHEET NUMBER MANUFACTURERS INSTALLATION INSTRUCTIONS. P\/_ 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. I �/ 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000-0 17.00-03.00-002.000 Zoho Sign Document ID:M2UVBXDBWH-1-61ULIB4H_YKJHR5Y9K5QIY6VLD_D40 CONSTRUCTION SUMMARY - MAIN HOUSE DESIGN d DRAFTING BY: (38) QCELL Q.PEAK DUO 15LK ML-G I O+ 400 WATT PV MODULES ELEMENT ENERGY LLC (DIMENSIONS: 74"X 4 1.I"X 1.3") REVIEW BY J.M.NABCEP CERTIFIE (38) ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS N 051112-129 (70)ATTACHMENT POINTS @ 72"O.C. MAX. 0° (263.5) LF IRONRIDGE XR 100 MOUNTING SYSTEM. REVISIONS ROOF TYPE: ASPHALT SHINGLE(SINGLE LAYER) I DESCRIPTION DATE REV W270a ORIGINAL 09-27-2022 CONSTRUCTION NOTES 240° n X90°E 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 210° V 120° WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 1$0°150 MINIMUM NEMA 3R RATING. S 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 'NOTE 1.)THE ROOF SETBACK/PATHWAY SHALL NOT BE CONTRACTOR REQUIRED TO DETACHED GARAGE IN ACCORDANCE WITH R324.G EXCEPTION OF I'-112" P-102 2020 NYS FIRE CODE ELEMENT ENERGY, LLC. 2.)THE ROOF SETBACWATHWAY SHALL NOT BE 7470 SOUND AVE REQUIRED-TO-ROOFS WITH-SLOPES-Of TWO- -- ----- -- -- ------- —----- _ _ —__ __ __ __ _ _ UNITS VERTICAL IN 12 UNITS HORIZONTAL OR —�-- - ---- -- - - - - - - -- - - -- --_ ___ - ____ ________ _ _ MATTITUCK, 1195 LESS IN ACCORDANCE WITH R324.G.I 11, LICENSE# 677 46-1-M - -- -- --� 3-9 ARRAY#2 I -O- LICENSE # 52689- E ME EXCEPTION OF 2020 NYS FIRE CODE 12 MODULES 2 I I°PITCH ARRAY#I 353°AZIMUTH 8 MODULE5 ' I J.PITCH 353°AZIMUTH NA T PROJECT NAME LLJ 1.. 211 1-2 11-21' z Lu [� W Ln QX (D 6� ___j — U-J J Lu Q z - - - > pw � m0 D LEGEND EXISTING UTIUTY METER MAIN SERVICE PANEL DISCONNECT ELS OF NE ARRAY#3 ARRAY#4 ARRAY#5 A/C D NEW �� Y G MODULES G MODULES G MODULE5 I °PITCH I I°PITCH I I°PITCH SHEET NAME COMBINER L INVERTERS \ 0 0 G�G���� 173°AZIMUTH 173°AZIMUTH 173°AZIMUTH e GND ELECTRODE aiif JJ ®PV MODULE ._ - ROOF DETAIL RACKING RAIL m W 2 O ATTACHMENT POINT ZNp f /�fA ---RAFTERS O 1034 DRAWING`/V -4—ROOF PITCH ANGLE A DRAWING SCALE Ro�ssloNP El Y,E SUNRUN METER 3/32" _ I I_OII ®VENT G pPLUMBING VENT ®SKY UGHT ®CHIMNEY SPIFFY NUMBER ®COMPOSITE 6HGOOD CONDITIONLES PV 3 POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY TAX MAP: 1000-01 7.00-03.00-002.000 Zoho Sign Document ID:M2UVBXDBWH-1-61ULIB4H_YKJHR5Y9K5QIY6VLD_D40 CONSTRUCTION SUMMARY - POOL HOUSE DESIGN 4 DRAFTING BY: (1 8) QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULES ELEMENT ENERGY LLC (DIMENSIONS: 74"X 41.I"X 1.3") (18) ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS N REVIEW BY J.M.NABCEP CERTIFIE 051112-129 (28)ATTACHMENT POINTS @ 72"O.C. MAX. 0° (124.5) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. REVISIONS ROOF TYPE: ASPHALT SHINGLE(SINGLE LAYER) I DE5CRIPf10N DATE REV W270� ORIGINAL 09-28-2022 CONSTRUCTION NOTES 240° X90°E 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE D 120° WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS. 210° 1500 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH I I_ I II 180° MINIMUM NEMA 3K RATING. 4 S 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. `NOTE POOL HOUSE 3 I CONTRACTOR I.)THE ROOF SETBACK/PATHWAY SHALL NOT BE REQUIRED TO DETACHED GARAGE IN ACCORDANCE WITH R324.G EXCEPTION OF 2020 NYS FIRE CODE ELEMENT ENERGY, LLC. 2.)THE ROOF 5ET5ACK/PATHWAY SHALL NOT BE 7470 SOUND AVE REQUIRED TO-ROOFS-WITH-SLOPES-OF-TWO-- - --- - -— __ _ _ _ _ _ _ _ _ -- --- ------ --- - -- -- - -- -- ---- -- - -- -- — MATTITUCK, NY I_I95 - --- ---- UNITS VERTICAL IN 12 UNITS HORIZONTAL OR LICENSE # G74G I-HI LESS IN ACCORDANCE WITH R324.G.I LICENSE # 52@89-ME EXCEPTION OF 2020 NYS FIRE CODE PROJECT NAME W U Z Lu Ln � w m � z - W^/ — L./ J LLJ W Q z Q 0 ~ m w O LEGEND EXISTING UTILITY METER OC IV NSIV MAIN SERVICE PANEL C NEW PV SUB-PANELS l�. RO A O A/C DISCONNECT r G/G �Q COMBINER Gj SHEET NAME INVERTERS Z a OND ELECTRODE * (, r �f► RR PV MODULE , ROOF DETAIL -RACKINGRAIL O ATTACHMENT POINT �O 1003445 �i=V ---RAFTERS 4-ROOF PITCH ANGLE R� SSlONP DRAWING SCALE �,E SUNRUN METER 3/1 611 _ P-0. ®VENT OPLUMBING VENT ARRAY#6 ®SKYLIGHT 16 MODULES . ® 34°PITCH SHEET NUMBER CHIMNEY 265°AZIMUTH ®COMPOSITE SHINGLES GOOD CONDITION FV-4 TRIM/REMOVE AS NECESSARY TAX MAP: 1000-017.00-03.00-002.000 Zoho Sign Document ID:M2UVBXDBWH-1-61ULIB4H_YKJHR5Y9K5QIY6VLD_D40 HAT ITEM DESCRIPTION ARRAYS #1-5 ARRAY#G (POOL hOU5E) DESIGN 4 DRAFTING BY: LOAD CALCULATION ARRAYRRAY (ARRAY#3) R6 Ride Beam/Doarci 2"X 10" D. FIR 2"X 10"D. FIR ELEMENT ENERGY LLC R Roof Rafter 2"X 8" D. FIR I G" O.C. 2"X 8° D. FIR I G" O.C. REVIEW BY J.M.NABCEPCERTIFIE MODULE WEIGHT(Lbs) 48.4 (D) Deckin 5/8"PLYWOOD 5/8"PLYWOOD 051112-129 #OF MODULES G G OF NE (J) Cei11n Jo1st 2"X 8" D. FIR P, G" O.C. N/A TOTAL MODULE WEIGHT(Lbs) 290.4 (P) Pitch 1 19 34Q REVISIONS ' _tt0 A G/G O� (C) Collar Ties 2"X 4" D. FIR 48" O.C. IN/A DE5CRIPTiON DATE REV l TOTAL LENGTH OF RAIL(Ft) 41.G CO � S� (h) horizontal Span of 1200 MAX. 152" MAX. ORIGINAL 09-27-2022 RAIL WEIGHT PER FOOT(Lbs) 0.68 TOTAL RAIL WEIGHT(Lbs) 28.3 C7 UJ rn #OF 5TRANDOFF5 24 4\+xrnsbL� (j WEIGHT PER 57RANDOFF(Lbs) 23443 TOTAL STANDOFF WEIGHT(Lbs) 48 AR�FESSIONP� TOTAL ARRAY WEIGHT(Lbs) 366.7 (P) (Re (R) (RB (D) (D) POINT LOAD(Lbs) 15.3 CONTRACTOR TOTAL ARRAY AREA(561 Ft) 128.5 ARRAY DEAD LAD(Lbs/Sq Ft) 2.9 ) ELEMENT ENERGY, LLC. 7470 SOUND AVE - -- — - -- ----WIND DESIGN-- --- - --- - -SUBJECT TO DAMAGE FROM— --- - -- - — ---- ------ -- __ - _ - -(CJ ------__-- GROUND SEISMIC WINTER ICE BARRIER FLOOD AIR MEAN ----- -- - ---- —-- - - - - -- - - -- - MATTITUCK,-NY 1-1-95- — --- -- --- SA'DIN Seo Topographic Special Wmdbome DESIGN Frost DESIGN UNDERLAYIhENT FREEZING ANNUAL LICENSE # 6746 I-111 LOAD' (mph) effectsl` wind debris CATEGORY' Weathering' line Termite` TEMP` REQUIRED° HAZARDST INDEX' TEMPI region' zone"' depth° LICENSE # 526(59-ME (H) (H) 20 140 NO NO NO B SEVERE 3 FT HEAVY 15'F YES ZONE X 599 51'F 0) IdANUAL J DESIGN CRITERIA" . ElevationLatitude Winter Summer Attitude indoor� sign temeating . - heating tooting correction facoor Am temperature cooling perature PROJECT NAME temperature difference [ARRAY#I] [ARRAY#21 108 FT 41'N 15'F B6°F 1.00 70'F 75"F 55'F W Coosmg Wind Wad Coincident Daily Winter Summer U temperature difference velocity velocity wet bulb range humidity humidity heating tooting z 11'F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GR @50%RH W W Ln For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL n (J-) Q a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth C/ J strength required for weathering shall govem.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. LU Q z b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction 0 < shall fill in the frost line depth column with the minimum depth of footing below finish grade. Q C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. MODULE MOUNTING CLAMP \ z d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined i on a site-specific basis in accordance with Section R301.2.1.4. SOLAR MODULE �G[� e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York m O State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also STAINLESS STEEL 3/8° (� see Figure R301.2(1).] BOLT AND NUT f. The jurisdiction shall fill in this part of We table with the seismic design category determined from Section R301.2.2.1. } g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: NRIDGE ALUMINUM RAIL i.The accompanying Flood Insurance Rate Map(FIRM), ALUMINUM°L°BRACKET ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. SHEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. ALUMINUM FLASHING h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." ST RU CTU RA 1. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." A5PHALT SHINGLE ROOF j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method 5/1 G"x G"5TAINLE55 (Base 32°F)." STEEL LAG BOLT WITH k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 2 1/2'MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION SEALED DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) AS NOTED m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table la or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at SHEET NUMBER elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. (') See Figure R301.2(4)B. TAX MAP: 1000-0 17.00-03.00-002.000 MOUNTING DETAIL 1 ZoNo Sign Document ID:M2UVBXDBWH-I-6IULIB4H-YKJHR5Y9K5QIY6VLD-D40 SOLAR ARRAY ON POOL HOUSE 7.2 kW (1 8)QCELL Q.PEAr,DUO BUR ML-G 10+400 WATT PV MODULES DESIGN k DRAFTING BY: (2)STRINGS OF(9)MICRO-INVERTERS '(2)STRINGS TOTAL �! of NEW Y REVIEW ELEMENT ENERGY LLC 'SYSTEM SPECIFICATIONS $ NOTES' ` BY J.M.NABCEPCERTIFIIf TOTAL SYSTEM SIZE: 22.4 kW STRING#5 �Q. 0 q GAG O,Q 05 Iz-129 MODULES: (5G) QCELL Q.PEAK DUO BLK ML-G 10+ 400 W PV MODULES - ----------- - INVERTERS: (5G) ENPHASE IQ8PLU5-72-2-U5 MICRO-INVERTERS i - - - - - 4-- - - - - * - REVISIONS 1 _ W DESCRIPTION DATE REV (38) MODULES INSTALLED ON MAIN HOUSE r- ------------- L ---- ---- ---- ---- ---- ---- ---- ---- � 4 w ORIGINAL 09-27-2022 (1 8) MODULES INSTALLED ON THE DETACHED GARAGE L m I2 MICRO-INVERTER �.^ �_ e& ,� rA L STRING#G 240 ACI 1.21 A Tzz-us VI V 97.5%CEC-WEIGHTED Err. �O 703445 En - _ _ HEMA G.UL LISTEDC�SIO��� TYPICAL SOLAR ARRAY ON MAIN HOUSE 15.2 kW (38)QCELL Q.PEAK DUO BLK ML-G)O+400 W PV MODULES I ENPHASE BRANCH TO UTILITY GRID (2)5TRING5 OF O2)MICRO-INVERTERS,(1)5TRING OF(8)MICRO-1NVERTER5,(1)STRING OF(G)MICRO-INVERTERS I CIRCUIT CARIE TYPICAL iO.Ni OF 1NF_RCONLNECnDN FER NES 2ar,211N r 6_J.EnrAl '(4)STRINGS TOTAL ON MAIN HOUSE OLAP,MODULE TYPICAL lE.¢Grn DF IA'�nDdaoRs AC DISCONNECT snaL voT EecE-D IDI u 2 N EJ rr��Il I E"''10 COMBINER 4 BI-DIRECTIONAL ___________ - sCA-R.ULez UTILITYMETER STRING#I I ""°°° e °" 24-'--,G A o I-PHA5E.2ER NEMA.R,u�_Limo CONTRACTOR -ti_ - • • • _ _ N 1 G N I (2)3JA-�E5 1 2 N r- TT I - - - I ^ I sc A PDIUTcr 1NTEccoRN=_crvoN zA I I ) _�N'_G caC.2l dPq tEeDfifAl --------------- - ELEMENT ENERGY, LLC. L1 ., x 7470 50UND AVE STRING#4 G 'I ------- --- MATTITUCK, NY 1 195 __ _ _ _ - - - • • • EIIPHASE ea_ 0.A utei 1 v,axV_c v1�D1scD F 1 L, L, - LICENSE # G74G 1-HI TERMUATOR 2���ed=° R LICENSE # 52689-Mf TYPICAL I 'I v.4C A I As Na,As FessseE FRcv L7 L7 vA sem,,<D1_caN"2cr I pIPHASE BRAt1CH MICRO-IUVERTER --------- ---------- I 2 I CIRCUIT CABLE TYPICAL ENPItA5E IOBPLU5-i2-2-U5 I 240 VAC,1 21 A 97.5%LEC-WEIGHTED FFP y- NEMA G.UL U5TED A L1 L7 TYPICAL AC DISCONNECT SUB PAN¢ N 2 I s:o D223uR5 PROJECT NAME NE oA 3P,UL LICIE L1 L7 (2)P.A FL5E5 I� N i ztU 2D?A N MAIN SERVICE PANEL ( c v G 1 � W Ln ( C COMBINER BO%4 r i D(15TING GROUNDING AQ (" ELECTRODE 5Y5TEM Q v � z,ALv._.e Pxe e._acct I I I I I U) I I L II W J L_ n W Q Z Q F- WIPE It CONDUIT SCHEDULE /\ O Z CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% � ,� W LD # ORIGIN DESTINATION UANTITY DEBATE INSULATION 51ZE QUANTITY INSULATION (CU/AQ SIZE PER POLE QL) TYPE SIZE TEMP DEBATE DISTANCE -n-a(ex3) sro IE(auzaYw_y I INVERTERS COMBINER PANEL AWG#12 1 8 0.7 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I" 55-C 0.84 110 FT OR EMT 2 COMBINER PANEL AC DISCONNECT AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 Cu PVC I" 45QC 0.95 25'T O.G% 3 COMBINER PANEL AC DISCONNECT AWG#)0 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45QC 0.95 10 FT O.G% 4 AC DISCONNECT MAIN PANEL AWG#6 1 3 1 THWN-2 AWG#8 1 THWN-2 Cu PVCI" 45QC 0.95 25 PT 0.6% 5 AC D15CCONNECT MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#8 I THWN-2 CU PVC I" 45QC 0.95 ;0 FT O.G% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NP.TL,AND LABELED FDR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation #5 PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO V AND 909C WET ENVIRONMENT. [NEC 690.8(8)(1)]:(15c)'(#of 5trin 5)'(1.5G)= 18.1 5 A [NEC G90.8(B)(1)]: (15c)'(#of 5trin 5)'(L.5G)= 27.23 A 3-LINE DIA. 3.)WIRING,CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 9 9 Modules per String 2 MAX. TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. AWG#10,ampacity`Temp Derate= e Size A AWG#6,ampacity`Temp Derate= i I.25 A 23.52 A> 18.15 A,therefore DC wire size is valid. 71.25 A> 27.23 A,therefore DC wire size Is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL #2 Inverter Output Wire Ampacity Calculation Number of Inverters 5G COMPLY WITH NEC 110.26. p p y 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output'(1.25)= 57.48 A Record low temp -109C FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL AWG#G,ampaclty'(Temp Derate)`(Conduit Fill Derate)= 71.25 A Voc Temp Coefficient -0.24%/°C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 71.25 A>57.48 A,therefore AC wire size IS valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation n I .T. . THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Amperage output'(1.25)= 27.23 A O eratin N Current 10.8 A I 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#10,ampacity'(Temp Derate)'(Conduit FILL Derate)=38 A O eratin Volta e 37.1 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 38 A> 27.23 A,therefore AC wire size is valid. Max. System Voltage 49.G V SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. #4 Inverter Output Wire Ampacity Calculation Short Circuit Current 13.9 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.G.VIA WEED LUG Inverter Max Amperage output'(1.25)= 57.48 A AC SYSTEM SPECIFICATIONS SHEET NUMBER OR I1-5CO GBL-4DBT LAY-IN LUG. AWG#G,ampacity`(Temp Derate)'(Conduit Fill Derate)=71.25 A 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5itive/ne6jative) 7 1.25 A> 57.48 A,therefore AC wire size IS valid. Max AC Output Current 84.7 A /` OR O eratin AC Volta p\ �e 240 V I v/ _G 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000-0 17.00-03.00-002.000 Zoho'Sign Document ID:M2UVBXDBWH-1-61ULIB4H_YKJHR5Y9K5QIY6VLD_D40 SERVICE METER O O DESIGN 4 DRAFTING BY: INSTALLATION NOTE ELEMENT ENERGY LLC SOLAR PV SYSTEM PHOTOVOLTAIC a • • • ( 1 ) ALL LABEL SHALL BE INSTALLED IN REVIEW BY J.M.N2-12PCERTIFIE • � 051112-129 EQUIPPED WITH lSOLARBREAKERa • ACCORDANCE WITH THE 2017 NEC REVISIonIs RAPID SHUTDOWN ® OPERATING VOLTAGEDREQU I REM ENT5. DESC I RIPTION DATE REV OPERATING (2) ALL LOCATIONS ARE APPROXIMATE AND ORGINAL 09.27.2022 SOLAR AC LOAD CENTER- OUTSIDE a �DONOTRELOCATETHISSHORT MAX SYSTEM VOLTAGE VDC REQUIRE FIELD VERIFICATION. B OVERCURRENTDEVICE (3) LABELS, WARNING(5) AND MARKING SHALL BE IN ACCORDANCE WITH NEC O TURN RAPID SHUTDOWN SWITCH TO 9 THE'Or'P POSITION TO SHUT DOWN O 1 1 0.2 1 (B). j PV SYSTEM AND REDUCE S*HAZARD_I'C ARRAY = AC DISCONNECT (4) THE MATERIAL USED FOR MARKING MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER- INSIDE O ® COMPLIANCE WITH NEC 1 1 0.2 1 (B)(3). CONTRACTOR (5) THE PV SYSTEM CIRCUIT CONDUCTORS ® OO ® I 1 ® I W N ! WARNING � � SHALL BE LABELED INSTALLED IN ELEMENT ENERGY, LLC. EQMOU FED EfYDUAL POWER SUPPLY ~; 7470 SOUND AVE OVERCUARSOUR CESENTDEVICCES.D(CCLLUDINc 'I SOURCES:UTILTTYGRID , COMPLIANCE WITH NEC 690.3 I MATTITUCK, NY 1 195 MAWSUMLYOVERCLIMUMr AND PV SOLAR LICENSE# 67461-HI DEVICE SHALLNOTEXCEED ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING AlMRUOFBUS9AR `�' LICENSE # 52689-ME 0 ! WA' NINE l _I ARN Gr i 7"DONOTADDLOADS 1 IS lasso"EwEo PROJECT NAME ELECTRIC SHOCK HAZARD �II PHOTOVOLTAIC SYSTEM TERMI,NAI.S O.N THE LWEANU ;�LOAD SIDES MAY BE EINERGQED U f ,+ .m j CONDUIT - OUTSIDE BUILDING IN THE OPEN POSITION W LLJ ® z Ln 7DUAL R�NER SUPPLY WJILISY GRID ANDCTRIC SYSTEM' W MAIN SERVICE PANEL - OUTSIDE OCAUTIONSOIARCIRCUIT > Z {{ Q O W _ACAUTION _ ® m R/ sOiAR EL cmc srsTe+1 CDIEcIED m O 6 � URRENT AMPS MAIN SERVICE PANEL - INSIDE i gRNING OPER TING VOLTAGE POWER SOURCE O JIS SFIEET NAME OUTPUT CONNECTION ® O j'-DO NOT RELOCATE THIS OF NEW OVERCURRENT DEVICE ,`� �O - - - ------- - - o a � ,p� LABELS AC DISCONNECT/BREAKER •� � �� DRAWING 5CALE X03443 �Ci= OOOO ® ARo ESSION N .T.S. F 5HEET NUMBER PV-7 TAX MAP: 1000-0 17.00-03.00-002.000