Loading...
HomeMy WebLinkAbout46396-Z ro�Og11FFU��c Town of Southold ` 8/31/2023 P.O.Box 1179 o 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44513 Date: 8/31/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 6155 Horton Ln, Southold SCTM#: 473889 Sec/Block/Lot: 54.-7-18.6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/24/2021 pursuant to which Building Permit No. 46396 dated 6/10/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. Maintain 36 inches around generator and 60 inches above for proper clearances to combustable. The certificate is issued to Baldridge,James&Donna of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49396 8/24/2023 PLUMBERS CERTIFICATION DATED t Au h riz d Signature u=� " TOWN OF SOUTHOLD �o�sFFncK�o� BUILDING DEPARTMENT Ca x TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46396 Date: 6/10/2021 Permission is hereby granted to: Baldridge, James 6155 Horton Ln Southold, NY 11971 To: install generator as applied for. At premises located at: 6155 Horton Ln, Southold SCTM # 473889 Sec/Block/Lot# 54.-7-18.6 Pursuant to application dated 5/24/2021 and approved by the Building Inspector. To expire on 12/10/2022. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO-ALTERATION TO DWELLING $50.00 Total: $235.00 ui nspector of so�ryQl . 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin(cb-town.southold.ny.us Southold,NY 11971-0959 Q�y�DUNT`l,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: James Baldridge Address: 6155 Horton Ln city:Southold st: NY zip: 11971 Building Permit#: 46396 Section: 54 Block: 7 Lot: 18.6 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Shore Power Electrical License No: 52536ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Generator X INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel 100A A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 300A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 22kW Generac Generator w/ 300A Whole House Transfer Switch Notes: Generator Inspector Signature: Date: August 24, 2023 S.Devlin-Cert Electrical Compliance Form -Lo, OFSOUTyO! �Q ! �� 4,00tw—lon # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: 0 -#v olaA ero�14 C' l Le Al eu�tods at fz&j /A f �ArtPe MA Wl ik tecygirroi ©b1 I CA CrAl • /0?1 .r .� �- f n ( OOA— fy_c Aat - : T-ewV 2 hmg yn?ti icroo 1-00A— DATE 2eP 22 INSPECTOR ` SOGTyolo � itOUTHOLD TO BUILDING DEPT. �ycouHr+, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) VLELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR OF 50�1�Olo 1 # * TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] NSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: c 'ev tSyl 0 CL DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS, FOUNDATION(1ST) H ------------------------------------ �b Q FOUNDATION(2ND) z 0 ROUGH FRAMING& t17 PLUMBING yJ 1 INSULATION PER N.Y. H STATE ENERGY CODE s y J Q • FINAL i ADDITIONAL COMMENTS . Lp C, . ` z rn O 0 N z y . d tai ro H TOWN OF SOUTHOLD-BUILDING DEPARTMENT y yz Y Town Hall Annex 54375 Main Road P.O. Box 1179 Southold,NY 11971-0959 y oar Telephone(631)765-1802 Fax(631) 765-9502 hgps://w*w.southoldtownny.gov if ! Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. P BuildingInspector. I - M AY 2 4 2021 lications and'forms.must,be f fled ouf-iri-thei entire'':.fncom ;aPpilCations ill;nOt be acceted =Where the.A 'IicantiS notafle owned`an` :,' ar 'Owner's Authorizatfon,form:(Page 2),shallbe completed: Date: �fg ,23 oZo G2/ WNER S OF PE :...-....:.,,.. _ ,O, PRO Name: 37, SCTM#1000- �' l- " ;7, Physical Address: to/SS No R -6 ANE v whk o I cQ 1 I N- Phone#: 7 3-7- 7 8 b7 7 Email:S E/j 1/I�G � OP_)-bN�%N6_• - -- Mailing Address: j _CP/ss NOPE CONTACT.PERSON { Name: 1�(< �.`/}�tCO - ,61" SIC#N OR- J� ZA ! 11,Aid012-09�*, Mailing Address: M_ f O sim RoAl-.5*.--A C r 498 i cAE S. N • / 34� Phone#: 631- 39J�� Email: , DESIGNPROFESSIONAL INFORMATION ' Name: Mailing Address: I Phone#: Email: ! , CO RACT MATI = - NT- OR INFORON:''-:;f - Name: Rr�'A-4 N iV -PKC• } Mailing Address: O$ � Phone#: fE"mailW _. .. . . 103 -- �3 � o.2-q- .__-- -- ------ cK@_ DESCRIPTION OF P. 31- CONSTRUCTION:". 1(New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ElOther 00 Will the lot be re-graded? I]Yes $No Will excess fill be removed from premises? ❑Yes ®No 4 1 1 I 11 _•.,- + - INFORMATION— - - - ORMAT Existing use of property: Intended use of property: I - - .. _. .i •- ENFXR7o Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes P4No IF YES,PROVIDE A COPY. Check Box A er:-R r ft- _ ead'ing:. Tile owner/contractov/design'professional is�espons�ble.for allmage andstorm Mrater issues asproiided by..'�.:.:.:;� Chapter 236 of the Town Code:APPLICATION IS HEREBY MADE to the Budding Uepartinent forthe-Issua'r ci of a Bmldmg Permit pursuant to a Building Zone Oidinariee 66hTown of Soutfiold,Suffolk;County,New-York and other-appBcable Laws,Ordinances of . gulations;for the'coristructiori of buildin" Bs. additions,alterations or far removal or demolition as hereimdescnbed The applicant agrees o empty all applieable laws,ordinances,building code, housing;code and regulations and to admit authoriiW inspectors,on premises and in buildings)dr'n ry.inspections.False statements made herein''are, ,�puni§ #;as a'dass A misdeineanor,pu`rsuaM to section 210.45 of the ii .4t rR State Penal law, II - - 1 nn Application Submitted By(pri t name): b S bad Authorized Agent ❑Owner Signature of Applicant: - , Date:_ S�a 3" o2oa-1 STATE OF NEW YORK) i S COUNTY OF ,It ) Dbeing duly sworn,deposes and says that(4he Is the applicant (Name of individual signing contract)above named, Ohe is the Apm4 ( i (Contractor,Agent,Corporate Officer,etch) of said owner or owners,and is duly authorized to perform or have performed thle said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Petru Holdon Sworn before me this Notary Public,State of New York No.01H06392941,Suffolk County Commission Expires Jun.3,2023 2 t� day of M2�:j ,2�_� Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, T_4MES 6 Ak dk%Jg E residing at (D 1'SS /7dR�7ZTN,B/ .C.�4/uE SeLA+WA I NY do hereby authorize �.o Uex ,(�E, �gu-�/S to apply on my behalf to the Town of Southold Building Department for approval as described herein. 4 S-��3-abZl Owner's Signature Date TAMOS .8,44eILdg. ' j Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold New York 11971-0959 o Telephone (631) 765-1802 - FAX (631) 765-9502 ` rogerr(cDsoutholdtownny.4ov seand(a-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: MAY as„.. .2.02,r Company Name: SAOR P6WJW JE/E rC4J- Cow4a4c-6v Nc- Name: JV;c K b M%C D License No.: 5 L 53 4- ME email:1V,*(:j<& o e owE& E &c: Address: /p g F,powEinl oA�-S�; E-a- Ce cvercl,Es N / Phone No.: JOB SITE INFORMATION (All Information Required) Name: Ugr1'F-s $ f d P-4 o- Address: /Q/ss /S/cR;kw ' Sa t..fAo[J, New ?�oazlC / Cross Street: J-5N, jtLd Phone No.: , - —8 D BIdg.Permit#: Y 6 --'>9,6 email EAVu.6 e 16 ,;V, A&A&-/,5 Tax Map District: 1000 Section: Jf Block: '7 Lot: /8• G BRIEF DESCRIIPTION'OF WORK (Please Print Clearly) N&4..411h / o14 o i A- 6i aNE2R s a,�k w *R-CnotEd S'�ANJ-4X-.9WXAe�Q Circle All That Apply: Is job ready for inspection?: YES 40 Rough In Final Do you need a Temp Certificate?: YES / '� Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected -Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH.APPLICATION - Request for Inspection Form.xls � _:.. -Fd( ; , BUILDING DEPARTMENT-Electrical inspector TOWN OFSOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 07 ',� Telephone (631) 765-1802 - FAX (631) 765-9502 . rogerr(c-southoldtownny.gov - seand(cDsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: MA Y -?-3A-L R-0�W Company Name: 3A,6&p Powjw C/Ec kr'c4L C0144&4C-�ji .z&c- Name: JV;c K D' Mi c o License No.: 5d-.5.3 G- ,M E email:Nt,'c j<p Shoe pawg52 Address: /p g F,po�EiAr o.4�—Ste; E-a. CF1•r}�ebm(I- �S Phone No.: 63/- 395- 009 JOB SITE INFORMATION (All Information Required) Name: Address: Cross Street: A Phone No.: s/ 8 -8 D 7 7 Bldg.Permit#: cf& :J9,6 email: SE4 Vu.E c> Tax Map District: 1000 Section: 5,4f Block: 7 Lot: /8. 6 BRIEF DESCRIPTION OF WORK (Please Print Clearly) iVs�All ioN v� + �,Gr4E2.4c �2xW /�a-Coo(ed Sive-6y ��rE.e � Circle All That Apply: Is job ready for inspection?- YES NO ' Rough In Final Do you need a Temp Certificate?: YES 1� Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Form.xls /A ll� PERMIT# Address: Switches Outlets GFI's Surface Sconces HH's LIC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro. Generator Combo - - - Cooktop ransfer AC AH Mini J Special: Comments: 10. .`� SURVEY OF PROPERTY ' SITUATED AT SOUTHOLD TOWN OF SOUTHOLD /. • , i SUFFOLK COUNTY, NEW YORK S.C. TAX No. 7000-54-07- 18 h oto + SCALE 1"=50' JULY 9, 1999 �, / 8• Fr-iL.MHER 77, 1999 ADDED BLIlLUINi. EN:11cIF1 MARCH; z- UNI)A D S11F Arlt • ,� a.t('a+51 ^G0; rt rIN TIa-iN uT;AflfTr. 4 LJA :u.- ilNaa vMf 'P. ` r p �4� 'tom f'\ • l'+� AREA - 45,501.68 sq ft. G (" Q` �`' �`� SiJc i-::i f.C=-it`°r•s it i L'>r KPS i H SEil"C,, ( II IN i po 2�w `• ' at Westawat6r Mangelrent { \ 7� 00•• 90 . CE R T / D Id. 1; i \ JAMES D. BALDRIDGE DONNA M BALDRIDGE ` �{ uweumaNez[D rrtRA1wR OR AsomaN PBEpAIaED a AL'COf+DANe}L> wwr 'OO• E.� .; N l"m SURWV is 40-mlw x STANDARDS RA Rill SURWM MTABUSIED SrucAta LA a THE NEW 1oR. Sr.rt MR S'Allte - STATE II Joseph A ingegno j WVS 0 TW-t,, T IMP NOT BEARI . r; � S&L SHALL P@OT Of s A=°G T -_ Land Surveyor CCR BE a VALE) UnT - C,V F 0 OR'PAI UR1N low. aTN6RO U[SRatY �f`:_•,: _—_-`__ ___—__ q PR(FAi A .0 DN 6 nneA<s it,M fitk Surren SrbdMsaorNS - Ste!Plor,e - CbeetnNctxm leryekrl I IENOYCLeW HOZZ44.' , li I[t TNC D[ lJ>�/NC.520- A=F TinXw CEnFrA"ON5 APL nor TPArsrFRAB't S. PHONE (516)727-2090 Fat (516)777-•1727 STs SNE E?1sUM OF RIGHT OF MATS TJ�TM EOCATE'D At I A!'D/T>(1 EASEYETYiS of RECORD. if +wJuwc ADOR($5 ART. NOT SHOWN ARE NOT GUARANTEED - — �— N Y.S. Lc Na S966H 342 R6A/OKE AVENUE P 0.Boa 1931 ' -- -- -- - -- RrAlb EA . Nees York 11901 RirateeoG, Ne•. York 11901-0865 4 Shore Power Electrical Contracting Inc. 108 Frowein Road — Suite 2 Center Moriches, NY 11934 MAY 2 4 2021 May 24th 2021 �. -.x, ..t... Re: Installation of a 22kW Generac generator for 3ames Baldridge, 6155 Norton Lane, Southold. 1000-54-7-18.6 Attached you'll find the necessary papers for a permit. If any information is missing or if you have any questions please contact our office manager Elizabeth at 631-395- 4029 elizabeth@)shorepowerelectric.com Thank you, Louis DeSantis Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name NICHOLAS D'AMICO Business Nasse This certifies that the bearer is duly licensed SHORE POWER ELECTRICAL by the County of suffolk CONTRACTING INC License Number:H48269 Rosalie Drago. Issued: 01/06/2011 Commissioner Expires: 01/01/2023 .r f - YORK Workers' CERTIFICATE OF snare Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board [18.Legal Name&Address of insured(use street address only 1 b.Business Telephone Number of Insured ore Power Electrical Contracting,Inc. 63195-4029 8 Frowein Road,mfg nter Moriches,NY 11934 1c.NYS Unemployment Insurance Employer Registration Numberof insured Work Location of Insured(Only required if coverage is specilieagF smiled to certain locadons in New York State,i.e.,a Wrap-Up 1 d.Federal Employer Identification Number of Insured or Social Security Policy) Number 20-4999886 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Hartford Casualty Insurance Company Town of Southold Town Hall Annex 3b.Policy Number of Entity Listed in Box"1 a" 54375 Route 25 12WECAB5PS1 Southold,NY 11971 3e.Policy effective period 07/20/2020 to 0712012021 3d.The Proprietor,Partners or Executive p8ioers are included.(Only check box if 611 partneWor6cets included) X all excluded or certain partnersfofficers excluded. This certifies that the insurance carrier indicated above in box`3"insures the business referenced above in box`1a for workers' compensation under the New York State Workers`Compensation Law. (To use this form,New York(NY)must be listed under itdrn 3A on the INFORMATION PAGE of the workers•compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.) Otherwise,this Certificate Is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until tate policy expiration date listed in box"3c•',whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect Please Notre.Upon cancellation of the workers•compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holderwith a new Certificate of Workers■Compensation Coverage or other authorized proof that time business is complying with the mandatory coverage requirements of the New York State Workers!Compensation Law. Under penalty of perjury,)certify that 1 am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by. Slanncin Carlson (Print name of authorized representaWe or licensed agent of insurance carrier) Approved by iz ( sv 11/09/2020 (Signature) Certificate Title: Certificate Coordinator Telephone Number of authorized representative or licensed agent of insurance carrier. 631-567-1011 Ext 352 Please NOW.Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it _ C-105.2(9-17) www.wcb.ny.gov AC Q SHORE-4 OP ID:SPC `..�- CERTIFICATE OF LIABILITY INSURANCE ffDATE(UWDW"M THIS CERTIFICATE 1S ISSUED AS A MATTER OF INFORMATION ONLY AND CON0912020 FERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER($), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT If the certificate holder is an ADDITIONAL INSURED,thepoGay fes)mustbe endorsed. If SUBROGATIONIS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in Neu Of such endorsemen s. PRODUCER ACr Hometown Insurance of LI,Inc � Anna Olmedo Weber Agency BONN x.631-5 5 Orville Drive,Suite400 67-1011 Fax No•631-589-4207 Bohemia,NY 11716 ADDS:AOlmedo Hometownlnsurance.com James Small INSU AFFORDING COVERAGE NAicm INSURmINSURERA:The Ohio CasualtyIns.Co. Shone Power Electrical Contracting,Inc. ..INSURER B:Hartford Casually Ins Co 29424 108 Frowein Road,#2 INSORERC: Center Moriches,NY 11934 INSURER D: INSURER E; F- COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED- NOTWITHSTANDING ANY REQUIREMENTT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO VNHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPEOFINSURANCE sm WVD POUCY NUMBER POLdD EFF P� A X coMMERCIALGENERALLIABUM LIMITS cLwlwsiuu►oE 0 OCCUR BKO(21)57918685 07/17/2020 07/17/2021 �EACH OCTCURRREN D a 1,000,00 PREMISES Eaocawwnce S 300,000 MED EXP(Airy one pelma) S 15,00 PERSONALSADVINJURY $ 1,000,00 GEN'L AGGREGATE rJMIT APPLIES PER: POLICY� EP ED LOC GENERALAGGREGATE S 2,000,00 PRODUCTS-COMPIOPAGG 5 2,000,00 POTHER: AUTOMOBILEUABR= S �a�lNdE�D1SINGLELWIIr s ALL ANY AUTO BODILY INJURY(Perpersan) S AUT S ASCHEDULED S BODILY INJURY(PeracddeM) S HIRED AUTOS AUTOS NEO _ AUTOS PeODAMAGE i UMBRELLA LVU3 S OCCUR EACH OCCURRENCE S EXCESS LUU3 CLAIMSMADE AGGREGATE y DED RETENTIONS WORKERS COMPENSATION $ AND EMPLOYERS'L IABUff PER QT}� B ANY PROPRErORWARTNER/EXECUiNE YIN 12WECABSPSI STATUTE ER OFFICEI21MIWBEREXCLUDED? N/A 07/20/2020 07/20/2021 E.LEACHACCIDENT $ 1,000,00 (Mandatory b NN) S 1,000,00 Uyres desoibe OF O EL DISEASE-FA DESCRO�IION OF OPERA77DNS hsWrx EL DISEASE-POUCYLOM r S 1,000,0 DESCRPRGNOFOPERATIONSILOCATKTNSIVEIUCLES(ACORD 101,AddWOnalRematksSchedWGmaybe adachedHmoWspace isrequirodl Proof of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCFJIED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Halt Annex ACCORDANCE WITH THE POLICY PROVISIONS, 54375 Route 25. Southold,NY 11971 AUTHOR¢®RMBENrAME I I , &"tA_ kl�� ©1988 2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD 1 .f_j HOM Workers' 5 ATE IC Compensation CERTIFICATE OF INSURANCE COVERAGE Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PARE 1.To be aorililpleted by Disability and Paid Family Dave Benefits Chmer or Licensed Insurance Agent of that Carrier la.Legal Name&Address of Insured(use street address only) lb.Business Telephone Number of Insured SHORE POWER ELECTRICAL CONTRACTING,INC 108 FROWEIN RD-#2 6313954029 CENTER MORICHES,NY 11934 Work Location of insured(only requiredifc+ove egeisspecwcaWffmitedto 1C•Federal Employer Identification Number of Insured certain loca8ons in New York Stale,i.e.,wrap-up Pony) or Social Security Number 20-4999885 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Town of Southold Standard Security Liffe Insurance Company of New York Town Hall Annex 3b.Policy Number of Entity Listed in Box"1a" 54375 Route 25 79516-00 Southold, NY 11971 3c.Policy effeditre period 1/1/2018 to 11/8/2021 4. Policy provides the following benefits: 0 A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefrts only. 5. Policy covers: E] A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or dosses of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability andlor Paid Family gave Benefits insurance coverage as de wed above Date signed 11/9/2020 By (sgnatmefirim mmcvdeesadhorizedrepmemtiveorNYSLicensedIns mceAgerdoft eluiauartce ) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBUPOLICY SERVICES IMPORTANT: If Boxes 4A and 5A are checked.and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE Mail it directly to the Certificate holder If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disabil'Ity and Paid Family Leave Benefits Law.It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-6200. PAW2-To W oompleted bythe WSWodmig Gbmp msabon Board(Ordytf Bbx4Cor5Bof Part 1 tiasbeen c tedeed) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (spudureof Authorized NY VWrkeW Comperesdion Board Employee) Telephone Number Name and Title Please Note.Only insurance carvers licensed to write NYS disabOy and paid famr7y leave beneft insurance policies and NYS licensed insurance agents of those insurance carvers are autlrodzed to issue Form DB-120.1. Insurance brokers are NOT authoraed to issue UIS form. DB-120.1 (1047) � 19I'�Ip��I�'�IIII�®I�IIRMI�� (�IIPD13_120.1 (10-17) �I� APPRO ED AS NOT D DATE: B.P:# ENE RAC FEE: O 2®, ZZ Z4 ICIl11 NOTIFYBUIIDING DEPARTMENT AT GUARDIAN R SERIES _ 765-.1802::8'AM TO 4 PM FOR-THE FOLLOWING:;INSPECTIONS: Residential Standby Generators 1: FOUNDATION =`TWO REQUIRED FOR POURED CONCRETE Air-Cooled Gas Engine 2. ROUGH -.FRAMING & PLUMBING 4. FINAL - CONSTRUCTION MUST Standby Power Rating INCLUDES: BE COMPLETE FOS'. 0037038-1,G007039-I,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power'"Electrical Technology ALL CONSTRUCTION 5gA(EE4V�7j%,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz I 1 tt G007209-0,G007210-0(Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution'"BEIQWOEMENTS OF THE CODES OF NEW (English/Spanish/French/Portuguese) YORK STATE. NOT RESPONSIBLE FOR • 200 amp service rated transfer switch availablPESIGN OR CONSTRUCTION ERRORS. • Electronic governor • Standard Wi-Fi®connectivity • System status&maintenance interval LED indica r COMPLY WITH ALL C(ODES OF =1 • sound attenuated enclosure EW YORK STATE & TOWN CODES AS REQUIRED AND CO , DITIONS OF • Flexible fuel line connector - _ • Natural gas or LP gas operation I GENERAC' _ • 5 Year limited warranty SI ` G BOARD • Listed and labeled by the Southwest Research Institute allowing $TEE$ installation as close as 18 in(457 mm)to a stru `' e 'Must be located away from doors,windows,and fresh air intakes and in N,Y.S,DEC accordance with local codes. https:11assets.swri.org/library/Directory07ListedProduc or C � QUSI -Constructionlndustry/973_DoC20913204O1Oi GCUPANCY 0(TP tXV �. USE I S U N LAWF 114 c�or CUL switches.Units appplies to unbundled units and units ppaacleg L h limited circuit switches.Units paclaged with the Smart Switch are EV or UL nified in the USA only. WITHOUT CERTIFICATE FEATURES UF OCCUPANCY O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when ifs needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component, appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby O PWRVIEW'" TRANSFER SWITCH: The Generac PWRview Automatic Transfer generators,Mobile Link Wi-Fi allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smartphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power.The PWRview energy monitor is a simple to use and Mobile Link,users are taken care of before the next power outage. low cost tool which helps save money over the life of the generator.Included with model G007210-0. ELECTRICAL "' G E N E R A L SM £.W GENERAC� I14SPECTION REQUIRED �IPROMISE OI� PWRIM GENERAC® 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows fora smaller,lightweight unitthat operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. •. Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. PWRview Transfer Switch(if applicable) • PWRview energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution'" Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. GENERAC 20/22/24 kW Features and Benefits Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI 221.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-pi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generators complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 20/22/24 kW Specifications Generator Model G007038-1 G007042-2 G007038-3 6007042-0 G007209-0 6007039-1 G007043-2 G007039-3 G007043-3 G007210-0 (20 kWJ (22 kW) (20 kW) (22 kW) (24 kW) Rated,maximum continuous power capacity(LP) -20,000.Watls` 22,000 Watts` 20;000 Walls* 22,000 Watts` 24,000 Watts` Rated maximum continuous power capacity(NG) 18,000 Watts' 19,500 Watts' 18,000 Walls` 19,500 Walls` 21,000 Watts' bated voltage_ 240 Rated maximum continuous load current—240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 406 Tolal'Harmonic Distortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase " 7-. 1 Number of rotor poles 2 °Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included),. - 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) 448/203 466/211 436/198 445/202 455/206 Dimensions(L x W:x H)in/cm 48 x 25 x29/121.9x 63.5 x 73.7 Sound output in dB(A)at 231t(7 m)with generator operating at normal load" 67 67 67 67 67 Sound outputin dB(A)at 23 ft(7m)with generator in Quiet-Test'"low-speed exercise mode* 55 57 55 57 . 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders = 2 Displacement 999 cc Cylinderblock- - Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system: Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC :Pit apacityincluding filter Approx.1.9 qt/1.8 L Operating fpm 3,600 Fuel consumption- Natural gas ft3/hr(m3/hf)" 1/2 Load, _ 204(5.78)-"_ 228(6.46) 164-(4.64) 203(5.75). Full Load 301(8.52)": . 321(926) 287(8.13) 306(8.66) Liquid propane ,- ft3/hr(gal/ho[L/hr] 1/2 Load 87(2.37)[8.99] 92(2.53)[9.57] 86(2:36)[8.95] 92(2.53)[9.57] Full'Lcad 130:(3.56)-[13.48] -142(3.80)•[14.77] 136(3.74)[14.15] 142(3.90)[14.77] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all lad ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply 113/hr x 2500(LP)or 113/hr x 1000(NG).For Megaloule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO - " Automatic start on Nility.failure.Weekly,Bi-weekly;or Monthly selectable exerciser. MANUAL Start with starter control,unit.stay s on .If utility fails,transfer to lad takes place. OFF = Stops unit.Power is removed;Control and charger still operate. Ready to RurVMaintenance messages Standard -Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) `Utility VoltageLoss/Retum.toUtilityadjustable(brdwnoutselling) - From 140-171V/190-216V Future Set Capable Exerciser/Exercise Set Error warning Standard Ruiolamr/Mairderprice logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Stader lock-0ut"-- " - Starter cannot re-engage until 5 sec after engine has stopped. Smad Battery Charger Standard Charger FaulUMissing AC.waming Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regpiation.with Over and Under Voltage Protection Standard under-Frequency/Overload/Stepper Overcurrent Protection Standard Safely Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High OitTempefature Shutdown Standard Ovehxank/Ovelspeed(@ 72 Hz)/rpmSense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal faultAncogecl Wiring protection Standard Common external fault capability Standard Field upgradabte,6rnfware" Standard "Sound levels are taken from the hart of the generator.Sound levels taken from other sides of the generator maybe higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).`Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine powerand condition,etc.Maximum power decreases approximately 3.5%for each 1,0000(304.8 m)above sea level;and also will decrease approximately 1%for each 10"F(6'C)above 60°F(16°C). GENERAC" 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Madel G0070394,G007039-3(20 kM • Intelligently manages up to four air conditioner loads with no additional hardware. 0007043 2,0007043-3(22 kW) No.of poles 2- • Up to eight additional large(240 VAC)loads can be managed when used in conjunction current rating(amps) 200 with Smart Management Modules(SMMs). Voltage rating(VAC) 1201240;16, • Electrically operated,mechanically-held contacts for fast,clean connections. Utility voltage monitor Ilixed)* • Rated for all classes of load,100%equipment rated,both inductive and resistive. -Pick-up 60% -Dropout 65% • 2-pole,250 VAC contactors. Return to Utility` Approx.l$sec r • Service equipment rated,dual coil design. Exercises bi-weekly for 5 minutes* Standard • Rated for both aluminum and capper conductors. t7L or UL listed Standard Enclosure type NEMA/UL 3R } Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker piolecled'_" 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly 200 Amps 120/240,10 Open Transition Service Rated Height Width d16.9 H1 H2 Wi W2 in 26.8 30.1 10.5 13.5 cm 67.95 76.43 26.67 34.18 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 PWRview Automatic Transfer Switch Features Model 6007210-0(24 kW) • Integrated PWRview monitor provides real-time energy usage data through PWRview app. No.of pales_ 2 Current rating(amps) 200 • Intelligently manages up to four air conditioner loads with no additional hardware. voltage rating(VAC) 120/240,10 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Utility voltage monitor(foxed)' with Smart Management Modules(SMMs). -Pick-up 80% ' • Electrically operated,mechanically-held contacts for fast,clean connections. -Dropout 65%Return to.Utility' Apprdx 13 sec - • Rated for all classes of load,100%equipment rated,both inductive and resistive. Exercises bi-weekly for 5 minutes* Standard • 2-pole,250 VAC contactors. tri.orULlisled Standard . • Service equipment rated,dual coil design. Enclosure type NEM' 3R Circuit breaker'protected ,' 22,000 • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly • Heavy duty Generac Contactor is an EM recognized device. `w Dimensions 200 Amps 120/240,1e Open Transition Service Rated Height Width H2 H1 Hi H2 W1 W2 Depth in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges ! Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 s GENERACO 20/22/24 kW Available Accessories _ Model#` :Product S. Description=>_;'. (3005819-0 26R Wet Cell Battery f Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact®). (3007101-0 BatteryPad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0*F(-18°C).(Not nec- essary for use with AGM-style batteries). '.G007102-0 0i1 Warnier Oil warimr slips directly over the oil filter._R ecommended for use if temperature regularly falls below 0°F(-18'C). ' ' 1 `G007103-1 .Breather Wanner Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 ` Auxiliary Transfer Switch The-at-dliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be. Contact ICIt needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque -Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured ;(Standard on 22 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. (3005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is importarnto to up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. GOd6485-0 Scheduled Maintenance IQ- `.Generac-'s scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a 'Generac automatic standby generator(oil not included). (3007005-0 Wi-Fi LP Tank Fuel Level The W-11i enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank Monitoring the Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected powerfa17ure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. GO 07000-0(50 amj.Smart Management Module Smart Manage merit Modules(SMM)are used to optimize the performan=ce of a standby generator.Itmanages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. (30071 69-0-4G LTE`Moble link`s Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-FV Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet -ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. =0072204_Bisque ,Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the rifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC 63T;m, IMmm [48.o ini G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 6964710742086 G007042-3 696471074208 inj G007043-2 696471074215 G007043-3 696471074215 a O O G007209-0 j 696471071511 3 1 G007210-0 696471078220 � 1232— roes a„ LEFT SIDE VIEW FRONT VIEW Dimensions shown am approArnale.See installation marvel formactdimensions.DO NOT USETHESE DIMENSIONS FOR INSTALLATION PURPOSES. O E N E RAC Generac Power Systems,Inc. •S45 W29290 HWY.59,Waukesha,WI 53189•generac.com ©2020 Generac Power Systems,Inc.All rights reserved.Ag specifications are subject to change without notice.Part No.A0000937814 Rev.A 07/15/2020