Loading...
HomeMy WebLinkAbout50035-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50035 Date: 11/16/2023 Permission is hereby granted to: Ciam a Douglas 23 Glen Way Cold Spring Harbor, NY 11724 To: legalize "as built" generator as applied for. At premises located at: 4380 Paradise Point Rd, Southold SCTM #473889 Sec/Block/Lot# 81.-3-6 Pursuant to application dated 11/1/2023 and approved by the Building Inspector. To expire on 5/17/2025. Fees: AS BUILT-ACCESSORY $250.00 ELECTRIC $200.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $550.00 Building Inspector TOWN OF SOUTHOLD —BUILDING DEPARTMENT a Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 ht1 s://iv-w w.soytI o1 tgjynq .g2v, Date Received APPLICATIONII YI 4 ri,l , M For Office Use Only N011 I PERMIT NO. Building Inspector: Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: /0 3 OWNERS)OF ROP R "Y: Name. i�D U 6- �l '0Z7R SCTM#1000- Project Address: -- Phone#: 90 lAeeels, 1 _ +�5-�-_ Email: Mailing Address: CONTACT PERSON: Name: Mailing Address: aa�S N6- Phone#: 6J?� _ _ Email: DESIGN PROFESSIONAL INFORMATION: i Name: Mailing Address: R �' 3S— " Phone#: _ Email: """' GIIGjELS 631 �3 � �'� L MaA# e CONTRACTOR INFORMATION: Name: Lp Mailing Address: Phone#: + �,3' — .f� ' Email: E�4 � L6�-)1464 DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑NRepair ❑Demolition Estimated Cost of Project: I ther Hce A .� ' -rA L oZ0 $ Will the lot be re-graded? ❑Yes ®14`8` Will excess fill be removed from premises? ❑Yes EiAlb 1 i ..�.� ..� �." _...,�.,�. � PROPERTY INFORMATION Existing use of property Intended use of property: Zone or use district in which premises is situated: Are there any covenants nd restriction: with respect to py�VNo IF YES, PROVIDE A COPY" " a Yes � thisro property? The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ofdlnames or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors an premises and in bulldhng(s)for necessary inspections.False statements made herein are punishable as a class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law, Application Submitted By(print name): Af "p, Authorized Agent ❑owner Signature of Applicant: ��. Date: 111f/D�c a� Notary Public,State of New York STATE OF NEW YORK) No. 01BU6185050 Qualified in Suffolk County SS: Commission Expires April 14, 21 COUNTY OF s. � .�..._....._ ) being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the ........ ITLLT(Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this W, 1 .. � .."day of_m. r '(._ _....... 20c5 � Notary Public �e , 0 FIR (Where the applicant is not the owner) .__residing at .. '�1 ,,, ' _ .. . hereby authorize � _� t ..r .. _ :to apply on my behalf t e Town of Southold Building Department for approval as described herein. io/L d/a 3 ner s Signature Date Print Owner's Name: 2 , ff Of BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 'amesh southoldtownn ov seand southoldtownn , ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: , Company Name: -' Sc>t, ` Electrician's Name: 40,6 ,Fe-< License No.: S 2$ M !c Elec. email: ,r 'OL . C'0 Elec. Phone No: 6131 - ?6S(6 request an email copy of Certificate of Compliance Elec. Address.: PG Q©,k 0d -- ,SOB SITE INFORMATION (All Information Required) Name: ex A Address: 43.90 ,- LelazX0401I Cross Street: *V W0,4,0 Phone No.: - Ste` Bldg.Permit#: 5c06,5 email: " ��oRf, Tax Map District: 1000 Section: Block: Lot: 6 c 0m BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All. That Apply: Is job ready for inspection?: YES NO Rough In ® Final Do you need a Temp Certificate?: YESra`N`0Issued On Temp Information: (All information required) Service Size 01 PhF]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 02 0 H Frame 0 Pole Work done on Service? Y hl Additional Information: PAYMENT DUE WITH APPLICATION KOHLER. Model: 48RCLC Multi-Fuel UU LPG/Natural Gas 09001 Standard Features ICtOHLER. • The generator set and its components are prototype-tested, NATIONALLY REGISTERED factory-built, and production-tested. • The generator set accepts rated load in one step. • A premium 5-year/2000-hour limited warranty covers all a • '1 = systems and components. G • Quick-ship(QS) models with selected features are available. See your Kohler dealer for details. • GFCI service outlet installed on the junction box. • RDC2 Controller o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT ATS). I(0 o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to changing demand. o Digital voltage regulation protects your valuable electronics from harmonic distortion and unstable power The Kohler* Advantage quality. • High Quality Power o OnCue®Plus Generator Management System for remote Kohler generators provide advanced voltage and monitoring is included with the generator. frequency regulation along with ultra-low levels of • Engine Features harmonic distortion for excellent generator power quality to o Powerful and reliable Kohler 6.21-liquid-cooled engine protect your valuable electronics. o Electronic engine management system. • Fast Response o Simple field conversion between natural gas and LP vapor Kohler's Fast-Response@ X excitation system delivers fuels while maintaining emission certification. (Optional excellent voltage response and short-circuit capability dual fuel automatic changeover kit is available.) using a rare-earth permanent magnet(PM)-excited • Innovative Cooling System alternator. o Electronically controlled fan speeds minimize generator • Quiet Operation set sound signature. Kohler home generators provide quiet, neighborhood- e Approved for stationary standby applications in locations friendly performance. served by a reliable utility source. • Premium 5-year/2000 hr Limited Warranty Included e Certifications Kohler is known for extraordinary reliability and performance. Kohler's premium limited warranty covers o The Hz generator set engine is certified the parts, labor, and travel for the full warranty period. Environmental Protection Agency(EPA)to conform to the New Source Performance Standard (NSPS) for stationary • Aluminum Enclosure spark-ignited emissions. Attractive aluminum enclosure allows installation as close o cUUUL listing, CSA certification standard are available. as 18 inches from your home or small business. Optional 291 kph (181 mph)wind-load-rated enclosure o Accepted by the Massachusetts Board of Registration of door kit is available for field installation. Plumbers and Gas Fitters. o Meets NFPA 37 requirements for 18 in.offset for installation. Generator Set Ratings Standby Ratings Standby Ratings Natural Gas LPG Line Circuit Breaker Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps Amps Poles 120/240* 1 60 44/44 184 44/44 184 — — 120/208 3 60 48/60 167 50/62 174 175 3 4P7BX 127/220* 3 60 48/60 158 50/62 165 — — 120/240 3 60 48/60 145 50/62 151 150 3 277/480 3 60 48/60 73 50/62 76 80 3 4Q7BX 120/240 1 60 48/48 200 48/48 200 200 2 * Voltage configuration not available from the factory.Field-adjustable by an authorized service technician. 1. 50 Hz options are available.Contact your Customer Service representative. RATINGS: All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings. Standby ratings apply to installations served by a reliable utility source. The standby rating Is applicable to varying bads for the duration of a power outage.There Is no overload capability for this rating. Ratings are in accordance with ISO-8528-1 and ISO-3046-1.Obtain technical information bulletin TIB-101 for ratings guidelines,complete ratings definitions,and site condition derates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.Availability is subject to change without notice. Contact your local Kohler generator dealer for availability. (34-306 (48RCLC) 2/23b t Alternator Specifications Specifications Alternator • The unique Fast-Response@ X excitation system delivers Manufacturer Kohler excellent voltage response and short-circuit capability using a Type 4-Pole, Rotating Field rare-earth, permanent magnet(PM)-excited alternator. Exciter type Brushless, Rare-Earth • Brushless, rotating-field alternator. Permanent Magnet • NEMA MG1, IEEE,and ANSI standards compliance for Leads:quantity,type temperature rise and motor starting. 4Q7BX 4,120/240 4P7BX 12,Reconnectable • Sustained short-circuit current of up to 300%of the rated Voltage regulator Solid State,Volts/Hz current for up to 10 seconds. Insulation: NEMA MG1 • Sustained short-circuit current enabling downstream circuit Material Class H breakers to trip without collapsing the alternator field. Temperature rise 130°C,Standby Bearing:quantity,type 1,Sealed e Self-ventilated and dripproof construction. Coupling Flexible Disc Amortisseur windings Full • Windings are vacuum-impregnated with epoxy varnish for Voltage regulation,no-load to full-load ±1.0%RMS dependability and long life. Unbalanced load capability 100%of Rated Standby • Superior voltage waveform from a two-thirds pitch stator and Current skewed rotor. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) • Total harmonic distortion (THD)from no load to full load with 480 V,400 V 4P7BX(12 lead) 180(60 Hz) a linear load is less than 4%. 240 V 4Q7BX(4 lead) 113(60 Hz) Application Data Engine Exhaust Engine Specifications 60 Hz Exhaust System 60 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type KG6208 6.21- Exhaust flow at rated kW,m3/min.(cfm) 16.4(580) Natural Aspiration Exhaust temperature at rated kW,dry Cylinder arrangement V-8 exhaust, °C(°F) 649(1200) Rated rpm 1800 Maximum allowable back pressure, Displacement,L(cu.in.) 6.2(378) kPa(in.Hg) 10.2(3.0) Bore and stroke,mm (in.) 101.6 x 95.25(4.00 x 3.75) Exhaust outlet size at engine hookup, Compression ratio 10.5:1 mm(in.) 76(3.0)OD Max.power at rated rpm,kW(HP) 77.0(103) Cylinder head material Cast Aluminum Fuel Piston type and material High Silicon Aluminum Fuel System Crankshaft material Cast Iron Fuel type LP Gas or Natural Gas Valve(exhaust)material Forged Steel Fuel supply line inlet 1 in.NPT Governor type Electronic Frequency regulation,no-load to full-load Isochronous Natural gas fuel supply pressure, kPa(in.H2O) 1.2-2.7(5-11) Frequency regulation,steady state ±1.0% Frequency Fixed LPG vapor withdrawal fuel supply q y pressure,kPa(in.H2O) 1.2-2.7(5-11) Air cleaner type Dry Fuel Composition Limits* Nat.Gas LP Gas Engine Electrical Methane,%by volume 92 min. — Engine Electrical System Ethane,%o by volume 4.5 max./a — Propane, by volume 1.0 max. 87 min. Ignition system Electronic Propene,%by volume 0.1 max. 5.0 max. Battery charging alternator: C4 and higher,%by volume 0.3 max. 2.5 max. Ground(negative/positive) Negative Sulfur,ppm mass 25 max. Volts(DC) 12 Lower heatingvalue, Ampere rating 130 MJ/m3(Btu/ft ),min. 33.2(890) 84.2(2260) Starter motor rated voltage(DC) 12 Fuels with other compositions may be acceptable. If your fuel is Battery, recommended cold cranking outside the listed specifications,contact your local distributor for amps(CCA): further analysis and advice. Qty.,rating for-18'C(0°F) One,630 Battery voltage(DC) 12 Lubrication Battery group size 24 Lubricating System Type Full Pressure Oil pan capacity,L(qt.) 5.7(6.0) Oil pan capacity with filter, L(qt.) 7.1 (7.5) Oil filter:quantity,type 1,Cartridge G4-306 (48RCLC) 2/23b 1 Application Data Cooling RDC2 Controller Radiator System 60 Hz Ambient temperature, °C ff) 45(113) a Radiator system capacity,including engine,L(gal.) 21.3(5.6) vaFreq: 60.0 Hzia9e: 240v Engine jacket water flow,Lpm(gpm) 131 (34.6) D � Heat rejected to cooling water at rated 0o a a kW,dry exhaust,kW(Btu/min.) 48(2730) E Water pump type Centrifugal 20 '° 'M Fan diameter,mm(in.) qty.3 @ 356(14) Fan power requirements(powered by engine battery charging alternator) 12VDC,18 amps each The RDC2 controller provides integrated control for the Operation Requirements* generator set, Kohler®Model RXT transfer switch, Air Requirements 60 Hz programmable interface module(PIM),and load shed kit. Radiator-cooled cooling air, The RDC2 controller's 2-line LCD screen displays status m3/min. (scfm)t 62.2(2200) messages and system settings that are clear and easy to read, Air over engine,m3/min.(cfm) 31.1 (1100) Combustion air,m3/min.(cfm) 5.5(195) even in direct sunlight or low light. 'f' Air density=1.20 kg/m3(0.075 Ibm/ft3) RDC2 Controller Features Fuel Consumption:}: • Membrane keypad: Natural Gas,m3/hr.(cfh)at%load 60 Hz o OFF,AUTO, and RUN pushbuttons 100% 24.8(875) o Select and arrow buttons for access to system 75% 20.3(717) configuration and adjustment menus 50%, 14.5(512) • LED indicators for OFF,AUTO,and RUN modes 25% 8.7(307) • LED indicators for utility power and generator set source 60 Hz availability and ATS position (Model RXT transfer switch LP Gas,at%load m3/hr.(cfh) Gal/hr. required) 100% 9.3(329) 9.0 • LCD screen: 75% 6.6(231) 6.3 o Two lines x 16 characters per line 50% 4.9(172) 4.7 o Backlit display with adjustable contrast for excellent 25% 3.1 (110) 3.0 visibility in all lighting conditions $ Nominal Fuel Rating: Natural gas,37 MJ/m3.(1000 Bt/ft3) Scrolling system status display LP Vapor,93 MJ/m3Cfo (2500 Btu/ft ) g y p y LP vapor conversion factors: o Generator set status 8.58 ft.3=1 Ib. o Voltage and frequency 0.535 m3=1 kg. o Engine temperature 36.39 ft.3=1 gal. o Oil pressure o Battery voltage * 50 Hz Operation Requirements are available upon request. o Engine runtime hours Sound Enclosure Features • Date and time displays • Smart engine cooldown senses engine temperature • Sound-attenuating enclosure uses acoustic insulation that a Digital isochronous governor to maintain steady-state speed meets UL 94 HF1 flammability classification and repels g at all loads moisture absorption. • Internally mounted critical silencer. • Digital voltage regulation: ±1.0% RMS no-load to full-load • Skid-mounted,aluminum construction with two removable • Automatic start with programmed cranking cycle access panels. • Programmable exerciser can be set to start automatically on • Scratch-and corrosion-resistant KohlerG'cashmere any future day and time,and to run every week or every two powder-baked finish. weeks • Exercise modes Sound Data o Unloaded exercise with complete system diagnostics Model 48RCLC sound levels are 61 dB(A)during engine o Unloaded full-speed exercise exercise and 61 dB(A) during normal operation.* o Loaded full-speed exercise (Model RXT ATS required) All sound levels are measured at a distance of 23 ft. (7 m)from • Front-access mini USB connector for SiteTech- connection the generator set.. • Integral Ethernet connector for Kohlerm OnCue@ Plus * Lowest of 8 points measured around the generator.Sound levels at other • Built-in 2.5 amp battery charger points around generator mayvary depending on installation parameters. a Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-306 (48RCLC) 2/23b KOHLER, Phone 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Additional RDC2 Controller Features Available Options(continued) • Diagnostic messages Fuel System o Displays diagnostic messages for the engine, generator, ❑ Dual Fuel Automatic Changeover Kit with Reset Box Model RXT transfer switch, programmable interface Enclosure Option module(PIM),and load shed kit ❑ 291 kph(181 mph)Wind Load Rated Enclosure o Over 70 diagnostic messages can be displayed Starting Aids§ • Maintenance reminders ❑ Block Heater,1500 W,120 V* • System settings ❑ Block Heater,1500 W,240 V o System voltage,frequency,and phase Single phase QS available with factory installed block heater § Recommended for ambient temperatures below 0 C(32 F) o Voltage adjustment Controller Accessories o Measurement system,English or metric ❑ Lockable Enclosure or Remote Mount Emergency Stop • ATS status (Model RXT ATS required) (lockout/tagout) o Source availability ❑ Programmable Interface Module(PIM) o ATS position (normal/utility or emergency/generator) (provides 2 digital inputs and 6 relay outputs) o Source voltage and frequency Automatic Transfer Switches and Accessories • ATS control (Model RXT ATS required) ❑ Model RXT Automatic Transfer Switch with Combined Interface/ o Source voltage and frequency settings Load Management Board o Engine start time delay ❑ Model RDT Automatic Transfer Switch o Transfer time delays ❑ Load Shed Kit for RDT or RXT o Fixed 1CkU d dropout settle ❑ Power Relay Modules(use up to 4 relay modules for pickup anp settings each load management device) o Voltage calibration ❑ Other Kohler@ ATS • Programmable Interface Module(PIM) status displays Miscellaneous o Input status (active/inactive) ❑ Maintenance Kit(includes air filter,oil,oil filter,and spark plugs) o Output status (active/inactive) Literature • Load control menus ❑ General Maintenance Literature Kit o Load status ❑ Overhaul Literature Kit o Test function ❑ Production Literature Kit Warranty Generator Set Standard Features ❑ Extended 7-Year/2000 Hour Premium Limited Warranty • Aluminum sound enclosure with enclosed silencer ❑ Extended 10-Year/2000 Hour Premium Limited Warranty • Battery rack and cables Dimensions and Weights • Coolant in generator Overall Size,L x W x H,mm(in.): 2280 x 836 x 1182 • WL/UL 2200 listed,CSA certified (89.8 x 32.9 x 46.5) • Electronic, isochronous governor Shipping Weight,wet,kg (lb.): 1 767(1690) • Engine-generator set is designed and manufactured in Weight includes generator set with engine fluids and 4Q7BX alternator, facilities certified to ISO:9001. sound enclosure,and silencer. • Flexible fuel line • Gas fuel system(includes fuel mixer, electronic secondary gas regulator,two gas solenoid valves, and flexible fuel line between the engine and the skid-mounted fuel system H components) • GFCI service outlet(120/240 V)for customer connections • Integral vibration isolation • Line circuit breaker r--- W L • NEC prime mover shutdown switch NOTE:This drawing is provided for reference only and should not be • Oil drain extension, used for planning installation. Contact your local dealer for more • OnCue@ Plus for remote monitoring detailed information. • Operation and installation literature DISTRIBUTED BY: • RDC2 controller with built-in battery charger • Standard 5-year/2000-hour premium warranty Available Options Electrical System ❑ Battery ❑ Battery Heater ❑ OnCue®Plus Wireless Radio Kit 0 2021 Kohler Co. All rights reserved. G4-306 (48RCLC) 2/23b