Loading...
HomeMy WebLinkAbout48796-Z p�OSOFFUt,fco� Town of Southold 8/11/2023 a yam , P.O.Box 1179 co 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44426 Date: 8/11/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 920 Cedarfields Dr, Greenport SCTM#: 473889 Sec/Block/Lot: 40.-5-1.25 Subdivision: Filed Map"No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/22/2022 pursuant to which Building Permit No. 48796 dated 1/25/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels and battery backup storage to existing single family dwelling as applied for. The certificate is issued to Love,Patrick of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48796 7/12/2023 PLUMBERS CERTIFICATION DATED th . ed ignature �o�gvFFoc,r�o TOWN OF SOUTHOLD ay BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48796 Date: 1/25/2023 Permission is hereby granted to: Love, Patrick 920 Cedarfields Dr Greenport, NY 11944 To: Install roof mount solar and battery backup storage at existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled and readily accessible. At premises located at: 920 Cedarfields Dr, Greenport SCTM #473889 Sec/Block/Lot#40.-5-1.25 Pursuant to application dated 12/22/2022 and.approved by the Building Inspector. To expire on 7/26/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector rg SO(/j�,ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(cD-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Patrick Love Address: 920 Cedarfiels Dr city:Greenport st: NY zip: 11944 Building Permit#: 48796 Section: 40 Block: 5 Lot: 1.25 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Long Island Power Solutions License No: 36178ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Battery Storage X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures 1 Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO 1 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump 11 Other Equipment: Enphase Encharge 20 Battery Storage System w/ (2) E10 Batteries, 40A Disconnect, 12.15kW Roof Mounted PV Solar Energy System w/ (30) rec405aa Pure Modules, Combiner Panel Notes: Solar & Battery Storage Inspector Signature: Date: July 12, 2023 S.Devlin-Cert Electrical Compliance Form # * TOWN OF SOUTHOLD BUILDING DEPT. `ycou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:' m 644 er4- L.V,/ DATE INSPECTOR �O�a0ES0Uly�� �( rd,�'- r�i?OUTHO'717*'o TOWN BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] R NTAL REMARKS: rGoM I1f DATE INSPECTOR 50(/Th°� # # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ INSULATIO/-N./C/AULKING [ ] FRAMING /STRAPPING [ ] FINAL�(1�'� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REM S: yt a vcn/� DATE it bol3 INSPECTOR so f �`UT117 ce�P�� ct S # # TOWN OF SOUTHOLD BUILDING DEPT. °`ycourm,N�' 631-765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]' RENTAL REMARKS: �vt�, D far- C�_ kit�f�°v` DATE 7- INSPECTORkA4AtP4J CIE OVE Di J U L 1 8 2023 BURMING DEPT. TOO ` '`ITI ' 4 _ k �S I 1 .,. ;� �� �., R •=r,' i i'� y - 1 f 1 � s 4. .V .t � y :i 'r •f Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave,Suite 2B P C Ph: 631-988-0000 Bohemia,NY 11716 �� G c solar@pacificoengineering.com June 14,2023 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Pat Love Section-Block-Lot: 40-5-1.25 920 Cedarfields Drive Permit Number: 48796 Greenport, NY 11944 I have reviewed the solar energy system installation at the subject address on June 14,2023.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2020 Residential Code of New York State and ASCE 7-16. To my best belief and knowledge,the work in this document is accurate,conforms with the governing codes applicable at the time of submission,conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. Regards, rM IRalph Pacifico, PE Professional Engineer J AUG - 4 2023 A BUILDING DEPT. of CC m661 / Ralph PacifiF� gineer NY 066182/NJ 24GE04744306/FL 87297 f 1 YA .� t+ JUL 2 2023 1 2023 M w� J JI J U L 1 2 2023 rLTn,nrvG DEPT. T^' ti J U L 1 2 2023 BUIT.DING DEPT, Tn. s ` JUL 1 2 2023 BLT11,DING DEPT. To ' �C L��UI � (� r J U L 1 2 2023 BUILDING DEPT. .r�r-R. • c,�Y -r a r JUL 1 2 2023 BUII.DPiG♦yDEPT. 'Jw 1 � J U L 1 2 2023 JUL 1 2 2023 P::1T.nnc J* J U L 1 2 2023 PlIJ DING 1: . rl IELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) 3 ------------------------------- CIO ---- -- C FOUNDATION (2ND) N G � � ROUGH FRAMING& — PLUMBING "bo td v 1 INSULATION PER N. Y. — y STATE ENERGY CODE — `�k�atYi.,i j"t FINAL ADDITIONAL COMMENTS O V-70 1 23 E Cpm ------ m x ' �uFFa TOWN OF SOUTHOLD—BUILDING DEPARTMENT Ca Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: . Applications and forms must be filled out in their entirety. Incomplete DEC ` 2022 applications will not be accepted. Where the Applicant is not the owner,an Bll1LD1NGnM, Owner's Authorization form(Page 2)shall be completed. TovftFSou"LD Date: OWNER(S)OF PROPERTY: Name:Patrick Love SCTM#1000-40-5-1.25 Physical Address:920 Cedarfields Drive, Greenport,. NY 11944 Phone#:631-786-3461 Email:plove4696@gmail.com Mailing Address:920 Cedarfelds Drive, Greenport, NY 11944 CONTACT PERSON: Name:Sky Rivera/Long Island Power Solutions Mailing Address:2060 Ocean Ave.., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:permits@GoPowerSolutions.com DESIGN PROFESSIONAL INFORMATION: Name:Pacifico Engineering, PC Mailing Address:700 Lakelalnd Ave, Suite 2B; Bohemia, NY 1,1716 Phone#:631-988-0000 Email:Solar@pacificoengineering.com CONTRACTOR INFORMATION: Name:Michael Catizone/Long .Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:mike@longislandpowersolutions.com DESCRIPTION OF PROPOSED CONSTRUCTION SOLAR PANELS & BATTERY BACK UP ❑New Structure ❑Addition @Alteration ❑Repair ❑Demolition Estimated Cost of Project: @Other Proposed(30)panel roof mounted solar array.(12.150)kW System.BBU(2)Enphase Encharge 10 $48,468.29 Will the lot be re-graded? ❑Yes @No Will excess fill be removed from premises? ❑Yes @No 1 PROPERTY INFORMATION Existing use of property:Sin le Famil Dwellin Intended use of property:Sin le Family Dwelling - - ---- - -- ---- - _ 9_---- ----Y-__ —_.9 - - -- - -- -- - --- _ -9 - -- --Y- --- ---9 Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to _ this property? ❑Yes M No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Catizo a lectrical/Long Island Power Solutions Application Submitted By(pr e): I@Author' ed A ent ❑Owner Signature of Applicant:_ -- - Date:'L_��. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Michael Catizone being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this I S day of \l�t_�m�� 20Ij— LYNDE SUSETTE ESTABROOKE NOTARY PUBLIC,STATE OF NEW YORK PROPERTY OWNER AUTHOR12 ATI(INgistration No.OIES6259997 (Where the applicant is not the oner'l ualified in Dutchess County Commission Expires April 16,2024 I, \ ������ civ�, residing at �� �e aac�\�EAS r, Michael Catizone/Long Island Power Solutions �re p v��n �.0 \\°�y ado hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. %.�19-1:Owner's Signature —�Date Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 .3 Southold, New York 11971-0959 } L, Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov � seandCcD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Catizone Electrical/Long Island Power Solutions Name:Michael Catizone License No.: 36178-ME email: sue@longislandpowersolutions.com Address: 2060 Ocean Avenue,Ronkonkoma,NY 11779 Phone No.: 631-348-0001 JOB SITE INFORMATION (All Information Required) Name: Patrick Love Address: 920 Cedarfields Drive Greenport,NY 11944 Cross Street:Moores Lane Phone No.:631-786-3461 BIdg.Permit#: , email:plove4696ail.com 1 Tax Map District: 00 Section: 40 Block: 5 Lot: 1.25 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Proposed(30)panel roof mounted array. (12.15)kW System/Battery Back Up-(2)Enphase Encharge 10 Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected- Underground -Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Form.xls LONG ISLAND C1112060 Ocean Ave Ronkonkoma, NY 11779OW E R SOLUT IONS 631348-0001 �7 i X1.7 www,longislandpowersolutions.com December 15, 2022 TOWN OF SOUTHOLD—Building Division Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Dear Building Dept: As per your Building Department, enclosed please find the building permit application, submitted on behalf of our client/property owner: Property Owner: Patrick Love—631-786-3461 Project/Property Address: 920 Cedarfields Drive, Greenport,NY 11944 Section/Block/Lot: 1000-40-5-1.25 Electrician/36178-ME: Michael Catizone—2060 Ocean.Ave.,Ronkonkoma,NY 11779—(631)348-0001 Contractor/53562-H: LI Power Solutions—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Architecture&Planning: Pacifico Engineering—700 Lakelalnd Ave, Ste 2B,Bohemia,NY 11716-631-988-0000 Enclosed Please find: • Application Fee: $200.00 • Permit Application • (4) Copies of the Property Survey • (4) Copies of the Engineering Drawings& Specs • Liability,Disability &Workman's Comp Insurance Certs Please send the Receipt and Permit to Long Island Power Solutions. Should you require anything further, please contact me. Sincerely, Sue Estabrooke, Permit Man ger Long Island Power Solutions 2060 Ocean Avenue Ronkonkoma,NY 11779 Ph- 631-348-0001 Fx- 631-348-0018 Permits@Gopowersolutions.com Go Green Save Green Suffolk County Dept.of Labor,Licensing&Consumer Affairs j _ HOME IMPROVEMENT LICENSE Name MICHAEL J CATIZONE Business Name j This cr t the LONG ISLAND POWER SOLUTIONS INC nearer is is duly licensed i �y the County of suffoik i License Number:H-53562 Rosalie Drago Issued: 06/0612014 Commissioner Expires: 06/0112024 _. Suffolk County.Dept-of Labor,Licensing&Consumer Affairs r k NAS7ER ELECTRICAL LICENSE .x: Name a< f.IICHAEL CATIZONE F Business Name r;t,s WrAPs:Nat IreLON^v tSLANI)P 0 W E R SOLUTIONS iNC nearer is Cult'hcer'w V?Ire CCunsy Of Suffolk License Number.AMIE-53560 Rosallo Drago issued: 06106,2014 Commiy,,iorer Expires:: 0E1OV2024 Client#: 83393 LONGISL15 ACORD,, CERTIFICATE OF LIABILITY INSURANCEDATE(MM/DDIYYYY) 2/07/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder,Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAMEACT : Commercial Support Edgewood Partners Ins.Center act°No at):63190-9700 F 40 Marcus Drive E-MAIL arc No): 631-390-9790 ADDRESS: NECertificates@epicbrokers.com 3rd Floor INSURER(S)AFFORDING COVERAGE NAIC# Melville,NY 11747-2647 INSURER A:Southwest Marine&General Ins Co 12294 INSURED INSURERS Long Island Power Solutions,Inc. DBA New York Power Solutions INSURERC: 2060 Ocean Avenue INSURER D: Ronkonkoma,NY 11779 INSURER E: INSURER F COVERAGES - CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUB POLICY EFF POLICY EXP LIMITS LTR I SR WVD POLICY NUMBER MM/DDIY MM/DD A X COMMERCIAL GENERAL LIABILITY PK202200020693 2/28/2022 02128/2023 EACH ppOCCURRENCE $1,000,000 CLAIMS-MADE �OCCUR PA OR Eao.Tu ante $300 OOO X PD Ded:5,000 MED EXP(Any one person) $10,000 X Contractual Liab. PERSONAL&ADV INJURY $1,000,000 GENT AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY[ X] ECOT- F LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ A AUTOMOBILE LIABILITY PK202200020693 2/28/2022 02128/2023 E°aBcN,deD SINGLE LIMIT 1,000,000 ANY AUTO BODILY INJURY(Per person) $ SCHED AUTOS ONLY AUTOSULED BODILY INJURY(Per accident) $ X AUTOS ONLY X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY Per acadent A X UMBRELLA LIAB X OCCUR EX202200001789 2/28/2022 02/28/2023 EACH OCCURRENCE $5,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE s5,000,000 DED I X RETENTION$10000 I $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETORIPARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Town of Southold is included as additional insured for general liability coverage as required by written contract. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold, NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S3438616/M3437780 LJACO Yo RIC workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured LONG ISLAND POWER SOLUTIONS INC DBA NEW YORK POWER SOLUTIONS 2060 OCEAN AVE 6313480001 RONKONKOMA,NY 11779 Work Location of Insured(Only required/f coverage is specifically limited to 1 c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 27-1175107 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Company of New York TOWN OF SOUTHOLD P Y 53095 ROUTE 25 3b.Policy Number of Entity Listed in Box 1a SOUTHOLD, NY 11971 R97411-000 3c.Policy Effective Period 1/1/2015 to 7/19/2023 4. Policy provides the following benefits: A.Both disability and Paid Family Leave benefits. B.Disability benefits only. C.Paid Family Leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following Gass or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as desc' d above. Date Signed 7/20/2022 By (Signature of insurance carrier's authoriled representative or NYS licensed insurance agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT:lf Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only if sox 4B,4C or 56 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers' Compensation Board, the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers' Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form, DB-120.1 (12-21) IIIIIIIIIIIIIIIIII121IIIII1iIIIIiI1ll2liil2ll1nll�lll[I N Y S I F PO Box 66699,Albany',NY 12206 New York State Insurance Fund I nysif.coln CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAll AAA 271175107 '0 LOVELL SAFETY MGMT CO.,LLC , 110 WILLIAM STREET 12TH FLR NEW YORK NY 10038 0 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER LONG ISLAND POWER SOLUTIONS INC TOWN OF SOUTHOLD 2060 OCEAN AVENUE 53095 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2467 078-8 539135 04/01/2022 TO 04/01/2023 03/08/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2467 078-8, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS'COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT MICHAEL CATIZONE VICE PRESIDENT JOSEPH MILILLO TWO OF TWO OFFICERS LONG ISLAND POWER SOLUTIONS INC THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND ts, DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 396794370 111111II0111110000000000101021106504�I�I���I� Form WC-CERT-NOPRINT Version 3(08/192019)(WC Policy-246707881 U-26.3 198 [0000MM000102106%4][0001-000024670788][##z][15840-38][cerLNoP-CE r_I][O1-O0001] Client#:83176 CATIELE ACORM CERTIFICATE OF LIABILITY INSURANCEDATE(MMIDDNYYY) x/27/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder In Ileu of such endorsement(s). PRODUCER CONT NAMEA T Commercial Support Edgewood Partners Ins.Center PHONE A/C NoExt: AIC No 3rd Floor Marcus Drive ADDDRRRESS : NECertificates@epicbrokers.com 3rINSURER(S)AFFORDING COVERAGE NAIC# Melville,NY 11747-2647 INSURER A:Utica Mutual Insurance Company 25976 INSURED INSURER B: Catlzone Electrical Inc 2060'Ocean Avenue INSURER C: Ronkonkoma,NY 11779 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT;TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IN TYPE OF INSURANCE INS L SUBDR POLICY NUMBER MNWD� M NDCD/YYXP LIMITS A X COMMERCIAL GENERAL LIABILITY X CPP4784747 7/01/2022 07/01/2023 EACH p�OECCCUR��R��ENCE $110001000 ED CLAIMS-MADE �OCCUR PREMISES Ea,aurrrsnce $100,000 MED EXP(Any one person) $10,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE s2,000,000 X JECT LOC PRODUCTS-COMPlOP AGG $2,000,000 POLICY D PRO. F OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident ANY AUTO BODILY INJURY(Per person) $ AUTOS ONLY AUTOS BODILY INJURY(Pei accident) $ AUTOS ONLY NON-OWNED S ONLY Pe�a�IdentDAMAGE $ UMBRELLA LIAS OCCUR EACH OCCURRENCE $ EXCESS UAB CLAIMS-MADE AGGREGATE $ DED I I RETENTIONS $ A WORKERS COMPENSATION4766763 7/01/2022 07/01/202 X PER OTH- AND EMPLOYERS'LIABILITY 1TAT.TF ER ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N E.L.EACH ACCIDENT $500 OOO OFFICERIMEMBER EXCLUDED? Y N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $500,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached It more space Is required) Town of Southold Is included as additional Insured for general liability coverage as required by written contract. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE O 1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S4115391/M4115046 KOS01 _ YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name 5 Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Catizone Electrical Contracting Inc. 631348-0001 060 Ocean Avenue - Ronkonkoma, NY 11779 1 c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,a Wrap-Up Policy) 1 d.Federal Employer Identification Number of Insured or Social Security Number 202241963 2.Name and Address of Entity Requesting Proof of Coverage(Entity 3a.Name of Insurance Carrier Being Listed as the Certificate Holder) Utica Mutual Insurance Company 3b.Policy Number of Entity Listed in Box"1 a" Town Southold 4766763 53095 Route 25 3c.Policy effective period Southold,NY 11971 07/01/2022 to 07/01/2023 3d.The Proprietor,Partners or Executive Officers are included.(Only check box if all partners/officers included) 0 all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until.the policy expiration date listed in box"3c",whichever is earlier., This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the,coverage as depicted on this form. Approved by: Leonard Scioscia (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 6/24/22 (Signature) (Date) Title: Authorized Representative Telephone Number of authorized representative or licensed agent of insurance carrier. 631-390-9700 Please Note:Only Insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov STORK ATE Compensation Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured CATIZONE ELECTRICAL CONTRACTING, INC. 2060 OCEAN AVE 631-348-0001 RONKONKOMA, NY 11779 Work Location of Insured(Only required if coverage is specifically limited to 1c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-up Policy) or Social Security Number 45-5213112 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Company of New York TOWN OF SOUTHOLD � P Y 53095 ROUTE 25 3b.Policy Number of Entity Listed in Box 1a SOUTHOLD, NY 11971 R97483-000 3c.Policy Effective Period 1/1/2015 to 11/9/2023 4. Policy provides the following benefits: 0 A.Both disability and Paid Family Leave benefits. B.Disability benefits only. C.Paid Family Leave benefits only. 5. Policy covers: A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as des d above. Date Signed 11/10/2022 - By (Signature of insurance carrier's authorded representative or NYS licensed insurance agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR—DBL/POLICY SERVICES IMPORTANT:If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 46,4C or 513 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers' Compensation Board, the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'.Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. insurance brokers.are NOT authorized to issue this form. D13-120.1 (12-21) IIIIIIIP°!iiu1ii2i0m1iiiii(i1ii2iui2ii1)iil�ll� Bunch, Connie From: Joanie Okula <joanie@gopowersolutions.com> Sent: Thursday, April 13, 2023 1:20 PM To: Devlin, Sean Cc: Bunch, Connie Subject: Final Electrical Inspection Amended Documents - Love, 920 Cedarfields Dr, Greenport, Permit#48796 Attachments: Love, Patrick 225809-E-1 .pdf, Love, Patrick 225809-E-2 .pdf Hi, Enclosed please find our amended documents for this job for the inspection on 4/25 for review Please let me know if you need anything else. Thanks! Have a nie day!! Joanie Okula 2060 Ocean Ave, Ronkonkoma, NY 11779 joanie@gopowersolutions.com 631-348-0001 ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 1 HOUSE PHOTOVOLTAICS: NEMA3R ( ' ' I (30)REC405AA PUREE PHOTOVOLTAIC SOLUTIONS JUNCTION BOX MlWAC(TJO� CLftRB,T36.30JA IM/ERTEROUTPUTCONNECTION MAIN SOLAR SYSTEM (3)RED-LINE nLKAL}jRMRoACVM M 240 INVERTERS: DO NOT RELOCATE THIS AC DISCONNECT 2060 OCEAN AVENUE, VOLTAGE OVERCURRENT DEVil RONKO)348-0 1 11776 GREEN-GROUND ENGAGE CABLE 30)ENPHASE IQ8PLUS-72-2-US —==--------- (631)343-0001 CIRCUITS: LOVE #12 AWG THWN FOR HOME RUNS 00' 3 CIRCUITS OF 10 MODULEMODULES#fOAWG THWOVER 10N FOR HOME RUNS OVER 100' ( ) ( ) ---(3 LINE VOLTAGE MAIN SERVICE RESIDENCE IN I-OR 1}'PVC CONDUIT 100A R TIo r L1&L2 CONSUMPTION CTSMETER 20 CEDARFIELDS DRIVE )GREENPORT,NY 11944 100 A PV COMBINER m 631-786-3461 PANEL ENPHASE IQ SYSTEM 2 ' ' = S:40 B:5 L:1.25 CONTROLLER PRO ECT DATA:#225809 ESS HOLD DOWN 100A-2P INVE TER:(30)ENPHASE IO8PLUS-72-2-US OA-2P ENVOY K[TBRHDK125 MO LES:(30)REC405AA PURE OA-2P OA-2P 50A•2P-PV NFT46a 100A•2P G ERY:(2)ENPHASE ENCHARGE 10 MODEM 4DA-2P-ESS 5A-2P.ENVO B EAKE N' CKING:IRON RIDGE XR700 IFI COMM �FTENER: TAGE:12,150 F TYPE:COMPOSITION SHINGLES #t4AWG THWN D LOAD:-21PSF @ 13OMPH N G EUTRAL&GROUND 94 LINE�HWN 5116'DIA 5'SS LAGS © • •p � � LUGS ESSN RSDFlOAD­I (i)NEUT LINE G (1)NEUTRAL IN It PVC THWNCONDUIT EGC 7Lkl. IN1}'pVC CONDUITBACKUP SYSTEM LIMITATIONS G�Emu LUGSHOME OWNER MANAGED ESSENTIAL Ave,Suite 28 asAwGTHWN APPLIANCES DURING POWER OUTAGES Bohemia,NY 11716 EQUIPMENT LIST-ENCHARGE BACKUP SYSTEM (1)LINE1 (1)LINE2 (4)#12AWGTHWN HOME OWNER IS RESPONSIBLE TO MONITOR THE ENPHASE APP AND MANAGE h:631-98&0000 (1)ENPHASE COMBINER PANEL WI ENVOY S METERED (1)NEUTRAL ELECTRIC USE APPROPRIATELY DURING GRID OUTAGES,DOING SO WILL ENSURE (1)EMVOY COMMS KIT-COMMS-KIT-01 (1)#8 AWG THWN EGC THE PROJECTED AUTONOMY. (1j CELLULAR MODEM-CELLMODEM-11 IN VPVC CONDUIT ENPHASE RAPID olar@pacificoengineering.com 2)CONSUMPTIONCT-CT-20MPLIT 40A ESSENTIALAPPLIANCE AUTONOMY 100%LOAD(EXCLUDING MICROWAVE).18 HRS. WWW-pacificaengineering.com ( SHUT DOWN (1)PRODUCTION CT-CT-200-SPLIT(INCLUDED WITH ENVOY) 600V AC ADJACENT TO ELECTRIC METER POWERING ADDITIONAL APPLIANCES WILL REDUCE THE AUTONOMY. (5)20A-2P CIRCUIT BREAKERS SERVICE DISCO PV SYSTEM OPERATING CAPACITIES I LOAD CALCULATIONS: (1)ENPHASE SYSTEM CONTROLLER 2-EP2000101HM240US00 #6 AWG THAN PV PRODUCTION @ 100%SUNLIGHT=36.30 AMPS. (1)80A 2P BREAKER FOR PV WITH HOLD DOWN KR (1)LINE 1 DESIGNATED ESSENTIAL LOAD APPLIANCE LISTED BELOW.100%TOTAL ENERGIZED (1)30A 2P BREAKER FOR BATTERY (1)LINE 2 POWER=32.8 AMPS. (1)100A 2P MAIN SERVICE BREAKER (1)#B AWG THWN EGC (1j ENPHASE SYSTEM RAPID SHUTDOWN SWITCH IN V PVC CONDUIT BATTERY CONTINUOUS OUTPUTWATTAGE-NOT TO BE EXCEEDED:7680 WATTS (1)100A RATED FUSED DISCONNECT (2)90 AMP GLASS FUSE KITCHEN REFR GERAT OR (1)ENCHARGE IO BATTERY ENCHARGE 10 ENCHARGE 10 ESSENTIAL OIL FIRED UPRIGHT FURNACE (1)30A 600V DC SERVICE DISCONNECT BATTERY BATTERY COMPUTER/CELL PHONE CHARGING APPLIANCES WIFIROR ER LIG A LICENSED INTERIOR LIGHTING LICENSED PROFESSIONAL IS ILLEGAL NOTE: CONSTRUCTION OF 90 MINUTE FIRE RATED BATTERY PWEB svE:n•.n•(ansle) STORAGE CLOSET-BY OTHERS SUPPLY MATERIALS AS FOLLOWS: ATE: 10/6/2022 N 1.30'X 70'FIRE RATED DOOR DSIGN BY: MW 1-SMOKE DETECTORAS BUILT CH CKEDBSIGNS: Y: KO _ RE ENPHASE IQ 8 PLUS WI ENCHARGE 20 BATTERY STORAGE SYSTEM J ACCO ER: TE: E EWYO A ENE C RVATIONC 0 TE 1-PHASE,MA GLOADCENTER,125A ALL WIRING ET THE 2017 NEC AND 2020 ENERGY CODE TOWN OF SOUTHOLD CODE,20 TwNALELECTRIccODE.ASCE7- ELECTRICAL PLAN E-1 60A FUSED SERVICE RATED DISCONNECT r &DOWER SOLUTIONS 2060 OCEAN 7-NEW RONKONKOMA, YU779 (631)348-0001 LOVE RESIDENCE 920 CEDARFIELDS DRIVE GREENPORT,NY 11944 631-786-3461 S:40 B:5 L:1.25 PROJECT DATA:#225809 ENPHASE ELECTRIC INVERTER(30)ENPHASE IQBPLUS-72-2-US BACKUP SYSTEM MODULES:(30)REC405AA PURE BATTERY:(2)ENPHASE ENCHARGE 10 RACKING:IRON RIDGE XR100 WATTAGE:12,150 BASEMENT LEVEL - ROOF TYPE:COMPOSITION SHINGLES WIND LOAD:-21 PSF @ 130MPH FASTENER:5116'DIA SSS LAGS iHOT` Vc NATER BOILERE GC 700 Lakeland Ave,Suite 2B Bohemia,NY 11716 Ph:631-988-0000 solar@pacificoengineering.com ENPHAGE IO SYSTE13 90 NNm OFwE MTEO fl4TTEliTSTOMGECLO.sET xD.wtEDOUtsDExEutFLBttwt NETFA CNRVOLLER PVDDNtlHFRPINEL M�UDTEDBYD1N .MATEANLSTOvrvnv.pacificoengineering.cam �FouoBY ws.loxa ERsBE RUND MRSMUTICNSARE I t.]V XTX'FwE RATFD DOOR —4'-8" -10' FatwAAwvm of EG DN LONCRETEBLOCKFOUNOATION— Pw K E1FNi a uclrt aWW <BA.600feV Al'C- . LE�wEDxHEX3NEi TEB ONwC2N CHR NERGT STORAGE 9 6TYBSDT EM 4'2" MTTPCEl WA9 A CEEwO DOECi liq sEnwcLPwt6 DwEuuLuSD�ANDchCtDutwwGU tEsiaD (BlsIDET0.05E1 HCL051➢tE) STEEL FwwE wAll 3'�3' ALTERATION OF THIS DOCUMENT EXCEPF BY A STUGSTI— LICENSED PROFESSIONAL IS ILLEGAL \'\\ '}O NWMEDO�UIBOIOENEMEIEOTiDD METER DGCDreacT L- E. LOSEIENCLOSMEI PAPER SIZE'11'R 17'(ANSIB) EXbiwBY O t0s4 xAw ELEOTWD BER-E PANEL 1 DN REre DDR DATE: 10/6/2022 DESIGN BY: MW ENPHSE ENCHARGE 20 ENERGY BACKUP SYSTEM BASEMENT PARTIAL PLAN VIEW L«+DREIEFawoAToxwuE carsTRuneoBToIRERs. 510P't`'E ' CHECKED BY: KO REVISIONS: a ENSEMBLE ENERGY SYSTEM BASEMENT ELEVATION VIEW si 2020 RESIDENTIAL CODE OF NEWYORK STATE 2020 ENERGY CONSERVATION CODE OF NEWYORK STATE, E-2 o TOWN OFSOUTHOLDCODE,2017NATIONAL ELECTRIC CODE ASCE7.18. BATTERY DETAILS �l l� APPROVED AS NOTEDp OCCUPANCY OR DATE: � a3 B.P.# /� USE IS UNLAWFUL FEES--ABY. WITHOUT CERTIFICATE NOTIFY BUILDING DEPARTMENTAT 631-765-1802 8AM TO 4PM FOR THE OF OC C U PAN CY . FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBINQ 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. QtJ'I�L ' N/j''H AI_L CODES 0f= ALL CONSTRUCTION SHALL MEET THE NEW YORK STATE & TOWN CODES REQUIREMENTS OFTHE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR AS REQUIRED AND CONDITIONS OF DESIGN OR CON5TRUCTON ERRORS SOUTHOLD TOWN ZBA SOUTHOLD TOWN PLANNING BOARD Fire separation SOUTHOLD TOWN TRUSTEES retjuired as per N.`P.S.DEC NYS Code RETAIN STORM WATER RUNOFF RWffaca vmnCfM" PURSUANT TO CHAPTER 236 OF THE TOWN CODE. AERIAL OWER SOLUTIONS / 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631) 348-0001 LOVE RESIDENCE _`�O ,• 920 CEDARFIELDS DRIVE R-4 GREENPORT, NY 11944 # MODULES (7) ~ 631-786-3461 PITCH: 33° S: 40 B: 5 L: 1.25 AZIMUTH: 317° �o°� PROJECT DATA:#225809 INVERTER:(30)ENPHASE IQ8PLUS-72-2-US PGG 5 MODULES:(30)REC405AA PURE �5 CO PGG BATTERY:(2)ENPHASE ENCHARGE 10 5 RACKING:IRON RIDGE XR100 a6 PGGp� 6 e WATTAGE:12,150 �Q�QP q�'� SHEET INDEX ROOF TYPE:COMPOSITION SHINGLES '70 WIND LOAD:-21PSF @ 130MPH S-1 SITE PLAN FASTENER:5/16"DIA.5"SS LAGS R_5 S-2 DETAILS _ # MODULES (4) E-1 ELECTRICAL PLAN P C i - PITCH. 340 E-2 EQUIPMENT LAYOUT GIN Gr pc Asa ����P°G �ssA ° AZIMUTH: 1370 L-1 MOUNTING PLAN # MODULES (5) �y�9`N���\� �sy 9Tti R-1 700 Lakeland Ave, Suite 26 c PITCH: 34° 7 MODULES Bohemia, NY 11716 cis 0 q` # ( ) AZIMUTH: 3170 sA PITCH: 330 Ph:631-988-OM AZIMUTH: 1370 y� solar@pacificoengineering.com R-6 R-3 www pacificoengineering.com # MODULES (3) GENERAL NOTES # MODULES (4) PITCH: 15° -ENPHASE IQ8 PLUS MICRO INVERTER OF Nt PITCH: 34° AZIMUTH: 1370 Q AZIMUTH: 137° LOCATED ON ROOF BEHIND EACH MODULE. �'< P qV o 4Cj,�� O -FIRST RESPONDER ACCESS MAINTAINED �� AND FROM ADJACENT ROOF. #� Q -WIRE RUN FROM ARRAY TO CONNECTION IS L 40 FEET. NF -COGEN DISCONNECT IS LOCATED \'09 X6618` �Q,j ADJACENT TO UTILITY METER. ` �FESSIOc1P -LAYOUT SUBJECT TO CHANGE BASED ON kLTERATION OF TMS DOCUMENT EXCEPT BY SITE CONDITIONS AT DATE OF INSTALL LICENSED PROFESSIONLIS IL EGAL PAPER co —771 I LEGEND DATE: 10/6/2022 N DESIGN BY: MW MAIN SERVICE PANEL (INTERIOR) CHECKED BY: KO COGEN DISCONNECT REVISIONS: ® UTILITY METER O J FIRST RESPONDER ACCESS 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, REPRESENTS ALL FIRE CLEARANCE MINIMUM OF 36" UNOBSTRUCTED AS PER TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE7.16, SITE PLAN S■ o INCLUDING ALTERNATIVE METHODS THE 2020 RESIDENTIAL CODE OF NYS �,. vFo_ IronRidge XR 100 Rail OWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 '�� .�-' • - � (631)348-0001 LOVE �- Cap RESIDENCE 4zzt44t Mid!Clomp Flashing 920 CEDARFIELDS DRIVE � GREENPORT, NY 11944 ��`"*►,�_r End ctc..p _... 631-786-3461 S: 40 B. 5 L. 1.25 IronRidge XR 100 Rad �„ 5/16" x 5" Stainless PROJECT DATA:#225809 IronRidge XR 100 Rail INVERTER:(30)ENPHASE IQBPLUS-72-2-US Steel La Bolt MODULES:(30)REC405AA PURE Solar Module 1 b BATTERY:(2)ENPHASE ENCHARGE 10 _ RACKING:IRON RIDGE XR100 3/3—to x 3/4 WATTAGE:12,150 HEX HEAD @dt.T ROOF TYPE:COMPOSITION SHINGLES FLANGE NUT 3_5 /��� WIND LOAD:-21PSF @ 130MPH r J FASTENER:5/16"DIA.5"SS LAGS _P C E GIN GENERAL NOTES- 700 Lakeland Ave, Suite 2B -L FEET ARE SECURED TO ROOF RAFTERS @ 80" O.C. Bohemia, NY 11716 USING 5/16" x 5" STAINLESS STEEL LAG BOLTS. Ph_631-988-0000 -SUBJECT ROOF HAS ONE LAYER, solar@cificoceineerin .ccom www_pac ificoengineenng.com -ALL PENETRATIONS ARE SEALED AND FLASHED. Gj'�P QyQv RAC/,��y0, ROOF PITCH RIDGE RAFTERS LENGTH OVERHANG NOTES * °� `^ cc R1 33° 2"x10" 2"x8"@16"O.C. 19'-0" 6" KNEEWALL 7'-4" FROM RIDGE R2 340 2"x10" 2"x8"@16"O.C. 11 ,-g„ 6„ 9��ES IONP��j R3 150 2"x10" 2"x8"@16"O.C. 15'-7" 6" S ALTERATION OF TI-QS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL R4330 2"x10" 2"x8"@16"O.C. 12'-7" 6" PAPER SIZE II"x17"(ANSI B) 00 DATE: 10/6/2022 N R5 34° 2"x 10" 2"x8"@ 16"O.C. 12'-9" 6" DESIGN BY: MW Y CHECKED BY: KO R6 34 2 X10, �� �� 6 KNEEWALL 6 �� 2 x8 @16110.C. 181-311 -7 FROM RIDGE REVISIONS: O tl11 a 0 N DESIGNED AS PER ASCE 7-10 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, �■� MODULES MOUNTED FLUSH TO ROOF TOWN OF SOUTHOLD CODE 2017 NATIONAL ELECTRIC CODE.ASCE7.16. DETAILS ° NO HIGHER THAN 6"ABOVE ROOF SURFACE v. OWER # >f : F30) ENPHASE TOVOLTAICS: WARNING PHOTOVOLTAIC NEMA 3R Nil 05AA PURE SOI..UTIONS JUNCTION BOX BA1M COUTRrCl ff36.30 A INVERTER OUTPUT CONNECTION MAIN SOLAR SYSTEM 2060 OCEAN AVENUE, (4) RED-LINE Now>�uu 0R?A WACV L 240 V : DO NOT RELOCATE THIS AC DISCONNECT VOLTAGE r RONKO )348-0 NY 11779 GREEN-GROUND ENGAGE CABLE IQ8PLUS-72-2-USOVERCIlFtRE1VT DEVICE --- (631)348-0001 LOVE #12AWGTHWN FOR HOME RUNS UNDER 100' S OF (10) MODULES #10 AWG THWN FOR HOME RUNS OVER 100' (4)LINE VOLTAGE MAIN SERVICE RESIDENCE (1)NEUTRAL PER CIRCUIT 100A IN 1"OR 1}"PVC CONDUIT 920 CEDARFIELDS DRIVE PRODU TI N CT L1 & L2 CONSUMPTION CT'S METER N Z N GREENPORT, NY 11944 100 A PV COMBINER m m w 631-786-3461 PANEL ENPHASE IQ SYSTEM 2 �" S: 40 B: 5 L: 1.25 CONTROLLERT T 00A - 2P PROJECT DATA:#225809 ESS HOLD DOWN �` INVERTER:(30)ENPHASE IQ8PLUS-72-2-US O 1 A-2P ENVOY KIT BRHDK125 MODULES:(30)REC405AA PURE OA-2P80A-2P-PV NFT 40A ( ) OA-2P 100A-2P G BATTERY: 2 ENPHASE ENCHARGE 10 20A-2P MODEM 140A-2P-ESS 15A-2P-ENVO BREAKER WATTAGE:12,150 IWIFI COMM ROOF TYPE:COMPOSITION SHINGLES WIND#14A THWN #2 AWG THWN FASTENER:5/16"DIA 51 SS LAGS NEUTRAL&GROUND \_(1)LINE 1 L7rENVOY ESS NLUAU (1)LINE 2 — - HAZARDELECTRIC SHOCK LU S G RSD P (1)NEUTRAL Li,L2 (1)#6 AWG THWN EGC P i C' N---T TOJCH TE;zMINALS PV IN1}'"PVC CONDUIT BACKUP SYSTEM LIMITATIONS G N LUGS HOME OWNER MANAGED ESSENTIAL 700 Lakeland Ave, sure 2B #4PAN AWG THWN APPLIANCES DURING POWER OUTAGES Bohemia, NY 11716 EQUIPMENT LIST-ENCHARGE BACKUP SYSTEM (1)LINE 1 (1)LINE 2 (4)#12 AWG THWN HOME OWNER IS RESPONSIBLE TO MONITOR THE ENPHASE APP AND MANAGE Ph:631-988-0000 (1)ENPHASE COMBINER PANEL W/ENVOY S METERED (1)NEUTRAL ELECTRIC USE APPROPRIATELY DURING GRID OUTAGES.DOING SO WILL ENSURE (1)EMVOY COMMS KIT-COMMS-KIT-01 (1)#6 AWG THWN EGC THE PROJECTED AUTONOMY. (1)CELLULAR MODEM-CELLMODEM-M1 IN1}'PVC CONDUIT ENPHASE RAPID solar@pecificcengineering.com (2)CONSUMPTION CT-CT-200-SPLIT 50A SHUT DOWN ESSENTIAL APPLIANCE AUTONOMY @100%LOAD(EXCLUDING MICROWAVE):18 HRS. www-Pacifcoengineering-com (1)PRODUCTION CT-CT-200-SPLIT(INCLUDED WITH ENVOY) 600V AC ADJACENT TO ELECTRIC METER POWERING ADDITIONAL APPLIANCES WILL REDUCE THE AUTONOMY. �t (5)20A-2P CIRCUIT BREAKERS SERVICE G OF N�,Y DISCO PV SYSTEM OPERATING CAPACITIES 1 LOAD CALCULATIONS: P� p Y (1)ENPHASE SYSTEM CONTROLLER 2-EP200G101-M24OUS00 #8 AWG THWN PV PRODUCTION @ 100%SUNLIGHT=36.30 AMPS. QN O � '4C � (1)80A 2P BREAKER FOR PV WITH HOLD DOWN KIT (1)LINE 2 DESIGNATED ESSENTIAL LOAD APPLIANCE LISTED BELOW-100%TOTAL ENERGIZED * �, (1)30A 2P BREAKER FOR BATTERY (1)NEUTRAL POWER=32.8 AMPS. (1)100A 213 MAIN SERVICE BREAKER (1)EGC (1)ENPHASE SYSTEM RAPID SHUTDOWN SWITCHIN 1}"PVC CONDUIT BATTERY CONTINUOUS OUTPUT WATTAGE- NOT TO BE EXCEEDED:7680 WATTS 1� (1)100A RATED FUSED DISCONNECT (2)90 AMP GLASS FUSE KITC ENCHARGE 10 ENCHARGE 10 OIL FIIREDUPRIEN GHT FURNACE ESSIO GERATOR (1)ENCHARGE 10 BATTERY ESSENTIAL (1)30A 600V DC SERVICE DISCONNECT BATTERY BATTERY COMPUTER I CELL PHONE CHARGING APPLIANCES WFI ROUTER ALTERATION OF THIS DOCUMENT EXCEPT BY INTERIOR LIGHTING LICENSED PROFESSIONAL IS ILLEGAL rn NOTE: D CONSTRUCTION OF 90 MINUTE FIRE RATED BATTERY KITCHEN MICROWAVEPAPER SIZE:11'x 17'(ANSI B) S' STORAGE CLOSET-BY OTHERS SUPPLY MATERIALS AS FOLLOWS: DATE: 10/6/2022 oo c- 1-30"X 70"FIRE RATED DOOR DESIGN BY: MW N x 1-SMOKE DETECTOR CHECKED BY: KO REVISIONS: 76 ENPHASE IQ 8 PLUS W/ ENCHARGE 20 BATTERY STORAGE SYSTEM]j 0 J AC COMBINER: NOTE: 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, E■ 1-PHASE,MAIN LUG LOAD CENTER, 125A ALL WIRING TO MEET THE 2017 NEC AND 2020 ENERGY CODE TOWN OF SOUTHOLD CODE'2017 NATIONAL ELECTRIC CODE.ASCE746. ELECTRICAL PLAN 60A FUSED SERVICE RATED DISCONNECT OW E R SOLUTIONS 0 4 2060 OCEAN AVENUE, o RONKONKOMA, NY 11779 (631)348-0001 0 LOVE RESIDENCE ~ 920 CEDARFIELDS DRIVE GREENPORT, NY 11944 631-786-3461 & 40B- 5L: 1.25 PROJECT DATA:#225809 NEW ENPHASE ELECTRIC INVERTER:(30)ENPHASE IQ8PLUS-72-2-US BACKUP SYSTEM MODULES:(30)REC405AA PURE BATTERY:(2)ENPHASE ENCHARGE 10 RACKING IRON RIDGE XR100 WATTAGE:12,150 BASEMENT LEVEL ROOF TYPE:COMPOSITION SHINGLES WIND LOAD:-21PSF @ 130MPH FASTENER:5/16"DIA.5"SS LAGS HOT WATER BOILER 1 E- 6rr� �� 700 Lakeland Ave, Suite 2B Bohemia. NY 11716 Ph: 631-988-0000 ENPHASE RAPID SHUTDOWN solar@pac ificoengineering.com 90 MINUTE FIRE RATED BATTERY STORAGE CLOSET MOUNTED OUTSIDE NEAR ELECTRIC METER CONSTRUCTED BY OTHERS.MATERIALS TO BE WWW.paci Icoenglneenng-com PV COMBINER PANEL SUPPLIED BY LONG ISLAND POWER SOLUTIONS ARE ENPHASE 10 SYSTEM 2 AS FOLLOWS: EX fERIOR CONTROLLER 1-30'X 74.'FIRE RATED DOOR COMBIIER PANEL 1-SMOKE DETECTOR ENVOY COMM UNIGATIDNS vy 4-2 '-4" CEL UARANDNFI OSET SMOKE DETECTOR Y ~'4'-5" CONCRETE BLOCK FOUNDATION WALL ENPHASE 7��ORK LIGHT PAC 09CONT /^�/� 5/8"G PSUM A`_ [.^� T 0. WALLS AND CEILING y V' 8 SMOKE AINEX ELEINGCTRIC TRI00A DETECTOR MAIN ELECTRIC '�{�YV ENPHASE ENCHARGE 20 SERVICE PANEL CEILING HEIGHT N INCHES TSO � ), , 1 -$ ENERGY STORAGE SYSTEM ❑ 0 W77 -5 FILING HEIGHT 791NCHES TBD x Ew LIGHTING 518'GYPSUM TYPICAL 40A,600V AC WALLS&CEILING a DISCONNECT ENPHASE ENCHARGE 10 FRG�o'x is 6'-2.' -2 ENERGY DE CLOSET ENCLOSURE) O VV VV V 9,FEssto P� `STEEL FRAME WALL 3 I3 \, ENPHASE ENCHARGE 10 ALTERATION OF THIS DOCUMENT EXCEPT BY A 40A,800V AC STUDS TYPICAL I DISCONNECT ENERGY STORAGE SYSTEM LICENSED PROFESSIONAL IS ILLEGAL ENPHASE RAPID SHUTDOWN ( (INSIDE CLOSET ENCLOSURE) MOUNTED OUTSIDE NEAR ELECTRIC METER u.,-.�..+ PAPER SIZE:11'x 17'(ANSI B) 0) -EXISTING IODA MAIN ELECTRIC SERVICE PANEL co CONCRETE FLOOR DATE: 10/6/2022 04 DESIGN BY: MW 04ENPHSE ENERGY BACKUP SYSTEM BASEMENT PARTIAL PLAN VIEW CONCRETEFOUNDAnoNWALL 90MINUTEFIRERATEDBATTERYSTORAGECLOSET CHECKED BY: KO U CONSTRUCTED BY OTHERS. REVISIONS: L a ai ENSEMBLE ENERGY SYSTEM BASEMENT ELEVATION VIEW o - J N 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, E�2 TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE7-16. BATTERY DETAILS 0 pOWER LUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 LOVE RESIDENCE ❑ 920 CEDARFIELDS DRIVE GREENPORT, NY 11944 631-786-3461 S: 40 B: 5 L: 1.25 PROJECT DATA:#225809 R-3 INVERTER:(30)ENPHASE IQ8PLUS-72-2-US MODULES:(30)REC405AA PURE R-1 R-2 # MODULES (3) BATTERY:(2)ENPHASE ENCHARGE 10 # MODULES (7) # MODULES (5) RACKING:IRONRIDGEXR100 �.! WATTAGE:12,150 PITCH: 15' ROOF TYPE:COMPOSITION SHINGLES PITCH: 33' PITCH: 34' WIND LOAD:-21PSF @ 130MPH AZIMUTH: 137' FASTENER:5/16"DIA.5 SS LAGS AZIMUTH: 137° AZIMUTH: 317° pP t EGc" 700 Lakeland Ave, Suite 2B Bohemia, NY 11716 Ph_631-988-0000 I solar@pacificoengineering.com www_pacificoengineering.com I RA &Z�O•A'� R-4 R-5 # MODULES (7) 17 14' 16 # MODULES (4) R-6 11' 9 PITCH: 33° PITCH: 34° # MODULES (4) A9�FESSIONP��/ 8.5 AZIMUTH: 317° ° PITCH: 34° ALTERATION OF THIS DOCUMENT EXCEPT BY A 0 AZIMUTH: 137 LICENSED PROFESSIONALZONAL IS ILLEGAL 4 0 AZIMUTH: 137° PAPER SIZE:11"x 17'(ANSI B) ■ SPLICE BAR 0 DATE: 10/6/2022 00 DESIGN BY: MW N © PENETRATIONS 93 CHECKED 8Y: KO UFO 98 REVISIONS: 40MM SLEEVE 70 END CAPS 76 N CONSUMPTION o CRITTER GUARD 330' MOUNTING PLAN L-1 P�dfico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2BC Ph: 631-988-0000 Bohemia, NY 11716 G G c solar@pacificoengineering.com December 12,2022 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Pat Love 920 Cedarfields Drive Greenport, NY 11944 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A B C D Mean roof height 19.0 ft 19.0 ft 20.0 ft 19.0 ft Pitch 33 degrees 34 degrees 15 degrees 33 degrees Roof rafter 2x8 2x8 2x8 2x8 Rafter spacing 16 inch on center 16 inch on center 16 inch on center 16 inch on center Reflected roof rafter span 7.4 ft 8.5 ft 13.8 ft 9.5 ft Table R802.4.1(1)max allowable 18.5 ft 18.5 ft 18.5 ft 18.5 ft The climactic and load information is below: Ground Wind Live Load, CLIMACTIC AND Point GEOGRAPHIC DESIGN Exposure Snow Speed,3 Pnet per pullout Fastener Type Category Load, Pg, sec gust, ASCE 7, CRITERIA psf mph psf load,Ib Roof Section A B 20 130 18 201 SS 5/16"dia lag bolt,5"length B 18 201 SS 5/16"dia lag bolt,5"length C 33 369 SS 5/16"dia lag bolt,5"length D 18 201 SS 5/16"dia lag bolt,5"length Weight Distribution �F Nk� array dead load 3.5 psf o load per attachment 39.1 Ib Q�Q1� A�'�'�/ The subject roof has 1 layer of roofing. fir P 1t 1, Panels mounted flush to roof no higher than 6 inches above roof surface. r �� Ralph Pacifico, PE Professional Engineer g O v661�c .. Ralp a� i ineer Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2B C Ph:631-988-0000 Bohemia, NY 11716 1 J IG c solar@pacificoengineering.com December 12, 2022 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Pat Love 920 Cedarfields Drive Greenport, NY 11944 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section E Mean roof height 19.0 ft Pitch 34 degrees Roof rafter 2x8 Rafter spacing 16 inch on center Reflected roof rafter span 7.0 ft Table R802.4.1(1) max allowable 18.5 ft The climactic and load information is below: Ground Wind Live Load, CLIMACTIC AND Exposure Snow Speed,3 Pnet per Point GEOGRAPHIC DESIGN pullout Fastener Type Category Load,Pg, sec gust, ASCE 7, CRITERIA load,Ib psf mph psf Roof Section E B 20 130 18 201 SS 5/16"dia lag bolt,5"length Weight Distribution OF NEJ-y array dead load 3.5 psf Dr� load per attachment 39.1 Ib AL' The subject roof has 1 layer of roofing. k. Panels mounted flush to roof no higher than 6 inches above roof surface. Ralph Pacifico, PE Professional Engineer Ralph, Ad��B� ETigineer z 0 4 SOLAR`S MOST TRUSTED ® C C ZA z.. Gl i i7. L- �J z Tt` i t EXPERIENCE REE 405 \/vp 25 YEAR / 219 -/ 3, d�'� LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE o�� ICC PRODUET 5PEEIREATIONS SOLAR'S MOST TRUSTED PU 1,U IV 1821:1-2.5 V1.7:t0.11 Q CERTIFICATIONS 901[35.5] 460[18.1] IEC.6.1.2.1.5:.2.0.1.6,.IEC.6.1.7.30.:201.6.,..U.L.6.1.7.3.0.............. ........... IEC62804 PID ........... - 153.7(6.051 IEC 61 701 Salt Mi5t '" '"'* "" ­­`* _ ­"""­"....................------ 1100[43.3]+ IEC 'Ammonia Resistance ...............................................I..................................................... I011925-2 Ignitability(Class E) k.........................................................................I........................... 6.0±0.2 6.278.2...................D.yn.a.m.i.c..M.e.c.h.a-n.i.c.a.l..L.o.a.d ...................... [0.24--tO.O11 IEC 61215-2-2016 Hailstone(35mm) ...............................................................;­..................................... H, IEC.62321 Lead-free acc.to RoHS EU 863/2015 C� .................................... .................I ­­ I—-.............. M ISO 14001-20 04,ISO 9001:2015,0 HSAS 18001:2007 IEC 62941 Ell "P� take Owa 11±0.2 do'b 0. C C F tak­ywEEE­P11�t bU-k Lead-F- recyckgscheme ZRH[0.43±0.011 C2 WARRANTY' 20.5:t05 1200[47.21 Standard: REC Pr.T.� [0.8±0.021� ................................................................................................... Installed by an REC Certified, N Yes 153.7[6.051 System SiSolar Profezessional I r25 .................................................... Yes kW 25-500 kW .................................................. ....................................... 45[1.8] 22.5[0.91 671 J-3[26A±0.112J Product Warranty(yrs) 26 25 25 ..................................................................... ............ 0[1.21 Power Warranty(yrs) 25 5 25 .............................................. ................... Measurements in mm[in] Labor Warranty(yrs) 0 25 10 .............:............................................................................_............ Power mYear l . 98% 98% 98% , GENERALDATA .................................................................... ­­............................. I Annual Degradation 0.25% 0.25% 0.25% .................................................................................................... 132 half-cut REC heterojunction cells StjubIiMC4PV-KBT4/KST4(4MM2). Power in Year 25 92% 92% 92% Celltype: with lead-free,gapless technology I Connectors: in accordance with IEC 62852 See warranty documents ford_etails.Co_nclitions apply 6 strings of 22 cells in series' IP68onlywhen connected .......................................................................................................... ......................................................................................................... Glass; 3.2 mm solarglass with 4MM2solarcable,l.lm+1.2m �MAXIMUMRATINGS anti-.reflective surface treatment Cable: in accordance with EN 50618 Operational te, 40...+85°C I- -40...+85 ........................................................................................................... ...................................................................... ............................ .............- Backsheet: Highly resistant polymer(black) Dimensions: 1821x1016x30mm ..................*.........................................................*........... Maximum system voltage: 1000V . ........................................................ ............................................. ....................................................................................................... ......................................................................................................... Maximum test load(front): *+7000 Pa(713 kg/m2) . ......................................................................................................... Frame: Anodized aluminum(black) Weight: 20-5 kg I Maximum test load(rear): -4000 Pa(407kg/m2)' ........................................................................................................... ........................................................................................................... ................................................................................................................ 3-part,3 bypass diodes,lead-free' Max series fuse rating: 25A, Junction box: ! Origin: Made in Singapore ......................................................................................................... IP68 rated,in accordance with EC62790 Max reverse current: 25A 'Seeinstailation manual for mounting instructions. ELECTRICAL DATA Product Code*:RECxxxAA Pure Design load-Test load/1.5(safety factor) Power output-PMAX(WP) 385 390 395 400 ................................................................................................................................................................................. ............... YTEMPERATURE RATINGS- Watt Class Sorting-(W) 0/+5 .. 0/.,..5................0/+5..............._0/+5...............°/+5.. - ' ................................................................................ .............................. . 4C(±2'C) o Nominal Power Voltage-Vmpp(V) 41.2 41.5 41.8 42.1 42.4. .................................................................................... .............. ............................................................................ ............................................................................................................................ Temperature coefficient of PMAX: -0.26%/'C u Nominal Power Current-1,,,(A) 9.35 9.40 9.45 9.51 956 ................................................................................................................ I.. .......................................................................................................................................................................... ..................... Temperature coefficient of Voc: -0.249/./*C a in ..........................L............................................. Open Circuit Voltage-Voc(V) 48.5 48.6 48.7 48.8 48.9 .......................... ................................................................................................................................................................................................................ Temperature coefficient of I'c: 0.04V./'c Short Circuit Current-Isc(A) 10.10 10.15 10.20 10.25 10.30: The temperature coefficients stated are linear va F. ................................................................................................................................................................................................................. Power Density(W/M2) 208.1 210.8 213.5 216.2 219.0. ................................................................................................................................................................................................................. 9 LOW LIGHT BEH"IOUR Panel Efficiency(%) 20.8 21.1 21.3 21.6 21.9: Typical low irradiance performance of module at STC: Power Output-PmAx(Wp) I M 293 297 301 305 3091 .......................................................................................................I................................................................................................ e 'i Power Voltage-Vm,(V) 38.8 39.1 39.4 39.7 40.01 �11 0 ...........*................. ...........................................*........................................... ......................................... -- -------------------------';i?- -------- 9 y_ Nominal Power Current-lm�(A) 755 7.59 7.63 7.68 7.721 -------------------------- Z .................................................................................................... ............................................................................................... Open Circuit Voltage-Voc(V) 45.7 45.8 45.9 46.0 46.1! --- -- - ---------------------------------- ................................................................................................................................................................................................................... Short Circuit Current-Isc(A) 8.16 8.20 8.24__ _8.28 13.321 [,,;di.-.ce('W/m") i a I Values at standard test conditions(STC:air mass AM IS,irradiance 1000 W/M2,temperature 25*Q based on a production spread with a tolerance of P_V«&I.±3%within onewatt class.Nominal module operating temperature(NMOT:air mass AM 1.5,irradiance 800 W/mz temperature 20T,windspeed I m/s).*Where mx indicates the nominal power class(P_)at STC above. Founded in 1996,REC Group is an international pioneering solar energy ICtCV company dedicated to empowering consumers with clean,affordable RE C solar power.As Solar's Most Trusted,REC is committed to high quality, www.recgroup.com innovation,and a low carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs in North America, Europe,and Asia-Pacific. .�:ENPHASE. . m IQ8 and 'IQ8+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- - -- defined microinverters with split-phase power conversion capability to convert DC Easy to install power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling Enphase "•!� ,I High productivity and reliability • Produce power even when the year untedgrid is down - Aarranly • More than one million cumulative Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability hours of testing Microinverters Integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming CERTIFIED Complies with the latest L SAFETY advanced grid support Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements IQBSP-DS-0002-01-EN-US-2021-10-19 IQ8 and IQ8+ Microinverters INPUT DATA(DCI 108-60-2-US ,.. Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell I 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range -V —25-48 1 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage v 50 60 - Max DC current2[module Isc] A 15 Overvoltage class DC port I II DC port backfeed current mA O PV array configuration I 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA is .0 0: Peak output power VA 245 300 Max continuous output power VA ( 240 i 290 Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A I 1.0 I 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% Overvoltage class AC port AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 - MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40OF to+140°F) Relative humidity range I _ 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) - - --- 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") - - ---- Weight - - - - -- - 1.08 kg(2.38 lbs) Cooling I Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree - - - - -- PD3 - Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when Installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of mlcroinverters per branch in your area. I08SP-DS-0002-01-EN-US-2021-10-19 .Afir IRON RIDGE Roof Mount System F e P -Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance ® Online tool generates a complete bill of rating of the existing roof. 'materials in minutes. Integrated Grounding 20 Year Warranty ® UL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q WE p _ L A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability • 12'spanning capability • Self-tapping screws • Moderate load capability Heavy load capability • Extreme load capability • Varying versions for rails • Clear&black anod.finish Clear&black anod.finish Clear anodized finish • Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs AOL Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware High-friction serrated face Works with vent flashing •,Attaches directly to rail • IBC& IRC compliant' Heavy-duty profile shape Ships pre-assembled Ships with all hardware • Certified with XR Rails Clear&black anod.finish 4"and 7"Lengths Fixed and adjustable Clamps & Grounding End,Clamps Grounding Mid Clamps Q T Bolt Grounding Lugs ( Accessories NO L_ . Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish&black anod. Parallel bonding T-bolt Easy top-slot mounting • Snap-in Wire Clips • Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling • Perfected End Caps • Optional Under Clamps Mill&black stainless Swivels in any direction • UV-protected polymer Free Resources Design Assistant /A NABCEP Certified Training Go from rough layout to fully ®V, Earn free continuing education credits, engineered system. For free. • A, while learning more about our systems. Go to IronRidge.com/rm ®♦ Go to IronRidge.com/training ,U Data Sheet Enphase Storage System Enphase The Enphase Encharge 10T"' all-in-one AC-coupled storage system is reliable,smart,simple,and safe. It is Encharge 10 comprised of three base Encharge 3T""storage units,has a total usable energy capacity of 10.08 kWh and twelve embedded grid-forming microinverters with 3.84 kW power rating. It provides backup capability and installers can quickly design the right system size to meet the needs of both new and retrofit solar customers. i Reliable • Proven high reliability IQ Series Microinverters Ten-year limited warranty ! � " " `y y�' • Three independent Encharge storage base units r ENP SE Twelve embedded IQ 8X-BAT Microinverters u Passive cooling(no moving parts/fans) Smart • Grid-forming capability for backup operation • Remote software and firmware upgrade Mobile app-based monitoring and control r s' • Support for self consumption Utility time of use(TOU)optimization Simple • Fully integrated AC battery system • Quick and easy plug-and-play installation • Interconnects with standard household AC wiring Safe • Cells safety tested • Lithium iron phosphate(LFP)chemistry for maximum safety and longevity EN PHAS E. To learn more about Enphase offerings,visit enphase.com u Enphase Encharge 10 MODEL NUMBER ENCHARGE-10-1 P-NA Encharge 10 battery storage system with integrated Enphase Microinverters and battery management unit(BMU).Includes: j Three Encharge 3.36 kWh base units(B3-A01-US001-1-3) I One Encharge 10 cover kit with cover,wall mounting bracket,watertight conduit hubs,and interconnect kit for wiring between batteries(1310-C-1050-0) ACCESSORIES ENCHARGE-HNDL-R1 One set of Encharge base unit installation handles OUTPUT(AC) @ 240 VAC' Rated(continuous)output power 3.84 kVA Peak output power 5.7 kVA(10 seconds) Nominal voltage/range 240/211 -264 VAC Nominal frequency/range 60/57-61 Hz 7Rated output current _ I Peak output current 24.6A(10 seconds) Power factor(adjustable) 0.85 leading...0.B5 lagging -Maximum units per 20 A branch circuit —�-1 unit(single phase)u --� - ^Interconnection Single-phase Maximum AC short circuit fault current over 3 cycles 69.6 Arms Round trip efficiency2 89% _ �~ BATTERY Total capacity 10.5 kWh Usable capacity 10.08 kWh - Round trip efficiency 96% - - Nominal DC voltage 67.2 V -Maximum DC voltage-- - 73.5 V Ambient operating temperature range -15°C to 55°C(5°F to 1310 F)non-condensing Optimum operating temperature range 0°C to 30°C(32°F to 86°F) Chemistry -Lithium iron phosphate(LFP) MECHANICAL DATA Dimensions(WxHxD) 1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in) - -�J Weight Three individual 44.2 kg(97.4 lbs)base units plus 21.1 kg(48.7 lbs)cover and mounting bracket;total 154.7 kg(341 lbs) i Enclosure Outdoor-NEMA type 3R IQ 8X-BAT microinverter enclosure NEMA type 6 i Cooling Natural convection-No fans Altitude — Up to 2500 meters(8200 feet) — --- Mounting - Wall mount FEATURES AND COMPLIANCE Compatibility Compatible with grid-tied PV systems.Compatible with Enphase IQ Series Micros,Enphase Enpower,and Enphase IQ Envoy for backup operation. J Communication Wireless 2.4 GHz Services Backup,self-consumption,TOU,Demand Charge,NEM Integrity Monitoring Enlighten Manager and MyEnlighten monitoring options;API integration Compliance UL 9540,UN 38.3,UL 9540A,UL 1998,UL 991,NEMA Type 3R,AC156 EMI:47 CFR,Part 15,Class B,ICES 003 Cell Module:UL 1973,UN 38.3 Inverters:UL 62109-1,IEC 62109-2,UL 1741SA,CAN/CSA C22.2 No.107.1-16 LIMITED WARRANTY Limited Warrant7 >70%capacity,up to 10 years or 4000 cycles 1.Supported in backup/off grid operations 2.AC to Battery to AC at 50%power rating. 3.Whichever occurs first.Restrictions apply. To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Encharge 10,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-05-19 E EN P H A S E.