HomeMy WebLinkAbout49957-Z w w TOWN OF SOUTHOLD
ate BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
w "bra SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 49957
Date: 10/27/2023
Permission is hereby granted to:
.
500 Glenn Rd
Southold, NY 1197 _� ..._.
._...... ..�...... ... .... . _.1 � �_......._ .�._ ...... _._........ . _ _..._.. .
To: Construct alterations to an existing single-family dwelling to include in-kind window
and door replacements and a central HVAC system as applied for per manufacturers
specifications.
At premises located at:
500 Glenn Rd, Southold
SCTM # 473889
Sec/Block/Lot# 78.-2-23
Pursuant to application dated 1
pp 0/17/2023mmmm and approved by the Building Inspector.
To expire on w_4/27/2025, w
Fees:
SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $250.00
CO-ALTERATION TO DWELLING $100.00
_..-............._..._
Total: $350.00
�......_....
. .....................................
Building Inspector
TOWN OF SOUT OLD—BUILDING DEPARTMENT
Town Nall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959
Telephone(631)765-1802 Fax(631) 765-9502 littl)s://ww%v.southoldtownny.vo
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only
PERMITNO. BuildingInspector-J-62—y— � i,
Applications and forms must be filled out in their entirety.Incomplete
applications will not be accepted. Where the Applicant is not the owner,an
Owner's Authorization form(Page 2)shall be completed.
Date:.
OWNER(S)OF PROPERTY:
Name:500 Glenn Road LLC SCTM#1000-78-2-23
Physical Address:500 Glenn Road, Southold NY 11971
Phone#: Email:
Mailing Address:
CONTACT PERSON:
Name:Constantine Rigas
Mailing Address:22260 Main Road, Orient NY 11957
Phone#:917-509-8751 Email-c@rigasco.com
DESIGN PROFESSIONAL INFORMATION:
Name:
Mailing Address:
Phone#: Email:
CONTRACTOR INFORMATION:
Name:Cconstantine Rigas
Mailing Address:22260 Main Road, Orient NY 11957
Phone#:917-509-8751 Email:C@rigasco.com
DESCRIPTION OF PROPOSED CONSTRUCTION New Window, New Sliding Door, New Ducted AC System
❑New Structure [--]Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
ii Other Window/Door/Ducted Central AC $15,000
Will the lot be re-graded? Dyes 0 N Will excess fill be removed from premises? ❑Yes ❑No
1
PROPERTY INFORMATION
Existing use of property: Intended use of property:
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? ❑Yes i'No IF YES, PROVIDE A COPY.
19 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law.
Application Submitted By(pr'"t name): C rA�V' 1" e BAuthorized Agent []Owner
Signature of Applicant: Date: ��
CONNIE D.BUNCH
Notary Public,State of New York
STATE OF NEW YORK) No.01 BU6185050
SS: Ouatified in Suffolk County
COUNTY OF ) Commission Expires April 14,2 AW
being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this 1
t\'
'TY a; of
Notary Public
See separate to a t ri f°io
2
Building Department Application
ArUT0 ZA T O
(Where the Applicant is not the Owner)
I,Allison Christin Van Dusen,as member/agent for 500 Glenn Road LLC, property owner of
500 Glenn Road, Southold NY 11971, do hereby authorize Constantine Rigas to apply on my
behalf to the Southold Building Department for any and all needed permits.
vr-,
Oct. 11,2023
(Signature): �. (Date)
Allison Van Dusen
(Print Name)
-il- 49 q 5
RIGAS CO
BUILDING COMPANY + DESIGN STUDIO
500 Glenn Road, Southold NY
10/16/23
Scope
New ducted Central AC system. New ductwork as needed, new Amana air conditioner ASXH504810A and
Amana air handler AMVT48CP14. (Electrical work for new AC to be under separate electrical permit)
One new custom sized Anderson 400 series series double hung window, in existing window opening in
bathroom.
One new custom sized Anderson Frenchwood sliding door, in existing opening.
www.rigasco.com
631 323 8022
22260 main road, orient ny 11957
r
Heating&Air Conditioning A M VTSERI ES
ff ana
MULTI-POSITION, VARIABLE-SPEED,
ECM-BASED AIR HANDLER
WITH INTERNAL TXV
COMFORTBRIDGETm COMPATIBLE
1'z To 5 TONS
Comfortfridge
technology
Product Features
• Internal factory-installed thermal expansion • Rigid SmartFrame'°"cabinet
valves for cooling and heat pump applications • Cabinet air leakage less than 2.0%at 1.0 inch
• Variable-speed ECM blower motor H2O when tested in accordance with ASHRAE
• Integrated communicating ComfortBridge"Technology standard 193
• Commissioning and diagnostics via on board Bluetooth • Cabinet air leakage less than 1.4%at 0.5 inch
with the CoolCloud"'phone and tablet application H2O when tested in accordance with ASHRAE
o Auto configuration of the airflow standard 193
and tonnage in communicating mode • Horizontal orvertical configuration capabilities
• Provides constant CFM over a wide range of static • 21"depth for easier attic access
pressure conditions independent of duct system • DecaBDE-free thermoplastic drain
• CFM indicator pan with secondary drain connections
• Fault recall of six most recent faults • Screw-less sides and back helps to reduce
• Provides adjustable low CFM for condensation when installed in humid locations
efficient fan-only operation • Foil-faced insulation covers the internal
• Improved humidity and comfort control casing to reduce cabinet condensation
• Built-in compatibility with multi-stage heat pump • Galvanized,leather grain-embossed finish
and cooling applications • Glue-less cabinet insulation retention
• All-aluminum evaporator coil • Tool-less filter access
• AHRI certified;ETL listed • Field Installed 3 kW—25 kW electric heater
kits available
1 0 PARTS ; _
catwutvwtrx catavurrwnx
LIMITED ' ' c . «.um s.sn., ave nurmrrw srsrea
YEAR WARRANTY'i I �'n�"o""� cmnnm er mavoL
Intertek -�08001� B
BBB
`Complete warranty details available from your local dealer or at www.goodmanmfg.com.To receive the 10-Year Parts Limited7�","# '
Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California
or QuAbec.
SS-AAMVT www.amana-hac.com 12/22
Amana°is a registered trademark of Maytag Corporation or its related companies and is used under license.Ail rights reserved.
PRODUCT SPECIFICATIONS
NOMINAL RATINGS
Cooling(Btu/h) 24,000 30,000 36,000 36,000 42,000 48,000 48,000 60,000
BLOWER
Diameter 10" 10" 10" 10" 10" 10" 10" 11"
Width 6" 6" 6" 8" 8" 10" 10" 10"
COIL CONNECTIONS
Liquid 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"
Suction 3/4" 3/4„ 3/4„ 3/4" 3/4" 7/8" 7/8" 7/8"
Coil Drain Conned(FPT) 3/4" 3/4" 13/4" 3/4" 3/4" 1 3/4" 3/4" 3/4"
ELECTRICAL DATA
Voltage 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240
Minimum Circuit Ampacity 4.9/4.9 4.9/4.9 6.5/6.5 6.5/6.5 6.5/6.5 6.5/6.5 8.6/8.6 8.6/8.6
Max.Overcurrent Device 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15
(Amps)
Minimum VAC 197 197 197 197 197 197 197 197
Maximum VAC 253 253 253 253 253 253 253 253
Blower Motor
Ful(Load Amps(FLA) 3.9 3.9 5.2 5.2 5.2 5.2 6.9 6.9
Horsepower(HP) % % % % 3/< % 1 1
SHIP WEIGHT(LBS.) 117 134 134 158 158 158 160 172
*Airflow rate @.3 static
Note:Assumes dry coil;SUM correction for wet coil=4%(208V/240V)
SS-AAMVT www.amana-hac.com 3
Air
Aiia-ganO
8ASXH5
AMERICA'S BRAND FOR COMFORT"
HIGH-EFFICIENCY
SPUT SYSTEM AIR CONDITIONER
UP To 17SEER2
1'2 TO 5 TONS
standard Features Cabinet Features
• High-efficiency Copeland scroll compressor • Removable grille-style top design
• Advanced Copeland CoreSense technology compliant with UL 60335-2-40
• High-density foam compressor sound blanket • Heavy-gauge galvanized-steel cabinet
• Factory-installed filter drier • Baked-on powder-paint finish with
• High and low pressure switches 500-hour salt-spray approval
• Copper tube/enhanced aluminum fin coil • Steel louver coil guard with Rust-resistant screws
• Fully charged for 15'of tubing length • Top and side maintenance access
• Service valves with sweat connections • Single-panel access to controls with space
and easy access to gauge ports provided for field-installed accessories
• Contactor with lug connection • When properly anchored it meets the 2020 Florida
• Ground lug connection Building Code unit integrity requirements for
• AHRI Certified;ETL Listed hurricane-type winds(Anchor bracket kits available.)
GUMoaeMSYSTM
trx coawwrwrtx
C \�� 16 f:F3rrYlEtf eYMIfICI CHnF1�eY M/V GL
=6p 500r= =1501�Wr=
_ Intertek
® Proper sizing and installation of equipment is critical to •' Complete warranty details available from your local dealer or at
U T
achieving optimal performance.Split system airconditioners PAR'($ www.amana-hac.com.To receive the Lifetime Unit Replacement Limited
and heat pumps must be matched with appropriate coil Warranty(good for as long as you own your home)and 10-Year Parts
. components to meet ENERGY STARO criteria.Ask your Limited Warranty,online registration must be completed within 60 days
contractor for details or visit www.energystargov. of Installation.Online registration is not required in California or Cluebec.
The duration of warranty coverages in Texas differs in some cases.
SS-ASXH5 www.amana-hac.com 06/23
Aman^is a registered trademark of Maytag Corporation or its related companies and is used under license.All rights reserved. Supersedes 04/22
SPECIFICATIONS
01810A 02410A* 03010A* 03610A 04210A* I
CAPACITIES
Nominal Cooling(BTU/h) 18,000 24,000 30,000 36,000 42,000 48,000 60,000
SEER2 15.2 15.2 15.2 1S-2 15-2 15.2 15.2
Decibels(d BA) 71 72 71 74 71 72 75
COMPRESSOR
RLA 9.0 11.5 12.8 14.1 177 19.9 23.7
LRA 42.6 59.5 65 87.4 110.2 110 151 MODEL DIMENSIONS
Stage Single Single Single Single Single Single Two WH D" H�
Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll ASXH501810A* 26 26 27
ASXH502410A* 29 29 32
CONDENSER FAN MOTOR ASXH503010A* 1 35'' 35% 39%
Motor Type PSC PSC PSC PSC PSC PSC ECM ASXH503610A* 35% 35% 39%
ASXH504210A* 35% 35%2 36%
Horsepower 1/8 1/6 1/6 1/6 1/4 1/4 1/3 —>A XH504810A* 35% 35% 36%
FLA 0.70 0.95 0.95 0.95 1.30 1.30 2.80 ASXH506010A* 35% 35% 41%
REFRIGERATION SYSTEM *Note:All the Dimensions(W D,H)are for reference only.
Refrigerant Line Size'
Liquid Line Size("O.D.) W W. W, W, %" %.
Suction Line Size("O.D.) Y4a" %" Y. �" y
Refrigerant Connection Size
Liquid Valve Size("O.D.) %" W W %" %"
W.
Suction Valve Size("O.D.)2,3 W %" %" %" V %"
Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge64 72 101 102 177 180 209
ELECTRICAL DATA
Voltage-Phase(60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1
Minimum Circuit Ampacitys 11.9 15.3 17.0 18.6 23.4 26.2 32.4
Max.Overcurrent Protection e 20 25 25 30 40 45 50
Min/Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253
Electrical Conduit Size %"or W W or W W or W W or%" %"or%" %"or%" W or Y."
EQUIPMENT WEIGHT(LBS) 126 1 151 202 202 260 260 283
SHIP WEIGHT(LBS) 144 169 224 224 282 282 305
01-ho 0
ENERGY STAR®CERTIFIED E 0 M E
'Line saes denoted for 25'line sets,tested and rated in accordance with ARI Standard 210/240.For other line set len jor sizes,
refer to the Installation Instructions and/or the Long Line Set Applications guide.
Installer will need to supply''/."to A"adapters for suction line connections.
'Installer will need to supply Y."to 1Y.."adapters for suction line connections.
<Unit is factory charged with refrigerant for 15'of%"liquid line.System charge must be adjusted per the Final Charge Adjustment
procedure found in the Installation Instructions.
S Wire size should be determined in accordance with National Electrical Codes;extensive wire runs will require larger wire sizes
s Must use time-delay fuses or HACR-type circuit breakers of the same sae as noted.
Nonis
• Always check the S&R plate for electrical data on the unit being installed.
ENERGY SrAR NOTES
• Proper sizing and installation of equipment is critical to achieving optimal performance.Split system air conditioners and heat pumps
must be matched with appropriate coil components to meet ENERGY STAR criteria.
• Ask your contractor for details or visit www.energVstar.gov.The www.energystargov website provides up-to-date system combinations
certified to meet ENERGY STAR requirements.
SS-ASXH5 www.amana-hac.com 3