Loading...
HomeMy WebLinkAbout49830-Z rTOWN OF SOUTHOLD r BUILDING DEPARTMENT TOWN CLERK'S OFFICE " r SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 49830 Date: 10/4/2023 Permission is hereby granted to: Flanagan, Patrick 325 Wells Rd Peconic, NY 11958 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 325 Wells Rd, Peconic SCTM #473889 Sec/Block/Lot# 75.-6-3.2 Pursuant to application dated 9/18/2023 and approved by the Building Inspector. To expire on 4/4/2025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector ,z TOWN OF SOUTHOLD —BUILDING DEPARTMENT ENT Town tall ,annex 54375 Main Road P. ®. Box 1179 Southold. NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 Date Received APPLICATION FOR BUILDING I For Office Use Only PERMIT NO, C." Building Ins ecton h -- _ _ SEP Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building tialMllftnelt Owner's Authorization form(page 2)shall be completed, TOwq Of SOuth0ld Date: OWNER(S)OF PROPERTY: Name: SCTM#1000- - a Project Address: 2J 11 Phone#: r Email P l _ �¢ 1� •gym of i°-- ' C-0 ryl Mailing Address: ,. � t I 119 CONTACT PERSON: Name: Mailing Address: Phone#. ' , P 414-5 Email; DESIGN PROFESSIONAL INFORMATION. Name: Mailing Address:., Phone#: Email: CONTRACTOR INFORMATION: Name: IT- Mailing - .Mailing Address: 7 -i -7 Phone#: `�"` � � � Email °�����, -s � " DESCRIPTION OF PROPOSED CONSTRUCTION ct p ❑Newstr�aci.t�re ❑Additlo lAlteration l�Re air ❑Demolition 'Estimaed Cost of Project: Will the lot be re-graded? ❑Ye ,,tR"�lo ❑ Will excess fill be removed from premises? Yes gilo � w 5 3 P l _ , 1 PROPERTY INFORMATION Existing use of property: Intended use of property: M<S Zone r use district in which premises is situated: Are there any covenants and restrictions with respect to ,Q-s 21C) this property? ❑Yes ONO IF YES, PROVIDE A COPY. Check Box AfterReading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(printname): L-0 rak4- L) l Pf jj+p,_ Authorized Agent []Owner Signature of Applicant: /�- - Date: STATE OF NEW YORK) CC SS: COUNTY OF VLk-F-C-O l IG ) Ly-re-1 nem-bl t-`C C*+,-- being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the COY4Y-Gc- '9'- (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowle a 1pef;and that the work will be performed in the manner set forth in the application file therewith. PO 4c,J�te of N Notary Public,State+�i NewYorliE` No.0180 1481 ' Sworn before me this Qualified in Suffolk County Commission Expires November 17.20.2'b /, day of S� ��d� 20 _ N6Wy I<Ublic PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) l -1 - .J R Ll ) residing at 3 Z. 5 01 S O do hereby authorize Ejr_mea� 'er °j c--L to apply on Na I my beto the Town of Southold Building Department for approval as described herein. -- �✓ Owne sSignature Date &4t—lc.k. 10. i Print Owner's Name IIJ 2 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD ' .. Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rc erre.southldtownn o sea nd�southoldtownrr ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: I Company Name: E- j c f rl t_�1 14 Electrician's Name. ­, w. License No.: , -1 �y Elec. emailz Elec. Phone No ,,. ,� °� v ®I request an email copy of Certificate of Compliance Elec. Address.:')� � � ,i� l ° � �" n '° �l. i .. a ; JOB SITE INFORMATION (All Information Required) Name: ' -�n'c,►�. l A-Y-) Ct Ci Address: 25 Q 5 Lk Cross Street: " Phone No.: of r7 q 9-3 D1dg.Permit #: email: nq Tax Map District: 1000 Section: .- S, Block. Lot: 3 BRIEF DESCRIPTION OF WORD, INCLUDE SQUARE FOOTAGE (Please Print Clearly); ii G � lrole All That Apply: Square Footage: Is job ready for inspection?: YES'ENO Rough In Final Do you need a Temp Certificate?: YES N® �, Issued On Temp Information. (All information required) Service Size 1 Ph ,3 Ph Size: A # Meters Old Deter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead Underground Laterals 12 H Frame11 Pole Work done on Service? Y N . LJAdditional Information: i�.�__ Yd + r-, r y tls'.1s rx-) 15 ,3°� LA�j -? rC -+ -/ Li s PAYMENT DUE WITH APPLICATION r. .�. >1 /'"$ICCOar7w a✓ DATE(M#�I!'13ri YyYy CERTIFICATE OF LIABILITY INSURANCE 7112P2O 3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW_ THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT-' If tfle certificate holder Is an ADOITIONAL INSURED,tfte pollcy(les)must have AOGIITIOUAL INSURED provisions or be endowed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endarserpwrst(s,, PRODUCER rxel ROBERT S. FEDE INSURANCE AGENCY PHONE _• 3"f:ill a 17 rotes ..._ 23 GREEN STREET,SUITE 102 /4wit41a9ti;..••-•.•.•....— ........ ..._ �_. . ......_ HUNTINGTON,NY 11743 A D�RFs—S,.- ROBERT S.FEDE INSURANCE INSURI S AFFo typ CovrvAd 4 NAIC d A:_.�.. ..."",.. INSURER ATLANTIC CASUALTY INS.CO. INSURED X24210 Element Energy LLC IINNssu�'ITs; m 2 DBA ELEMENT ENERGY SYSTEMS c- .J� � AR 11AdEMS� 1T Iib" _.... 7470 SOUND AVENUE MATTITUCI<, NY 11952 RIsuErE': D�wss1IRER F COVERAGESCER'TIFIC TE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN lS SUBJECT TO ALL THE TERMS, _ F SUCH POLICIES-LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTRXCLU$fONSCONDITIONS S OTYPEOFIN••�NLILIT9 . COMMERCIAL GENERALI]ABI ,...��^....^ A - LIABILITY X X L14BOW6873 7711114 2202 3! 7/1414 EACH OCCURRE CE 3,000,000 CLAIMS-MADE OCCUR 7E.MI my ra ori nw r i S 100.000 X Contractual LIa IMA38s2�38 7/19/2022 7/19/2024 PERSONAL a AOV II~I, W'Y _ s_ . 3WO000 3,00000 "` GATE UMI7 APPLIES PER ` RODUCTS GCOMP OP AGG ._...._„ IrSd.*w+-'Sn!.'.... AML At GRE POLICY X]JPECT �LOC OTHER AUTOMOBILE LIABIUTY Comm,NED SINGLE.rJMI r s ANY AUTO _....._ eODILY INJURY(Per person) i LIW� _ ........ �_.._ .,, AUTOSTOS SCHEDULED ONLY AUTOS �iDILY INJURY(Per aceuieat) : HIRED NTIED CSVa IDAAdACxt AUTOSLY AUTOS ONLY f 3 s UMBRELLA LIAB �� �'OCCUR EACHRDCCUr2f ,VCE. EXCESS UAB CA GOREGATE _. .. e,ANraI�,^h�At�E ICED RE.TENT'I'CN'3 'NraftiSE1Rffi COMPENSATION AND EMPLOYER$UABLM 124494445 ANY . DRIPAR1NCPJEkFaVME YrN 7!1312023. 7113!2024 TA ER OFFICERIrA°'hISE.REXULIDED37 NrA EL EACH ACCIDENT 1,t�Ot) 1$LuMalWy in NH) _ I.._.0 VI�$ Uaad$r EL DISEASE EAIElV9I�. ± I7ESCR PTIDaY PIPER 1T&CMS EL DISEASE-POMY Lia wr NY State DBL 1 non(Ma DBL567527 1101!2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS[VEHICLES fACORD 161,Additional Remarks Schedule,wry be MaeW Irafore$pace is recoraM CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations an GL Waiver of subrogation is applicable to General Liability. 30 day notice Of cancellation applies. CERTIFICATEHOLDER CANCELLATION F54375 Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Main Road THE EXPIRATION DATE THEREOF', NOTICE WILL BE DELIVERED IN ld, NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS- AUTHCRRED REPRESENTATIVE RQZe+-tS. Fed--, Amon �c r�n�arnz� rhe ©1988-2015 98ACORD CORPORATION. All rights reserved. 15;� YS' F New York State Insurance Fund PO Box 66699,Albany,NY 122(]6 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) AAAAAA 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 0 SCAN TO VALIDATE AND SUBSCRIBE F HOLDERCERTIFICATE HOLDER NT ENERGY LLC TOWN OF SOUTHOLD LEMENT ENERGY SYSTEMS 54375 MAIN ROAD OUND AVENUE SOUTHOLD NY 11971 TUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD GATE 12449444-5 369075 07/13/2023 TO 07/13/2024 T/11/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444.5 COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS" COMPENSATION LAW "WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NE'O'N` YORK, EXCEPT AS INDICATED BELOW, .AND, WITIH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,, TO THE PCJLICYHOI DER'S REGULAR NEW YORK STATE EMPLOYEE'S ONLY. IF YOU VWSH TO RECEIVE NOTIFICATIONS REGARDING SAID POLI+CY;,INCLUIBIFIG ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,'VISIT OUR WESSITE AT H7-rPS."IAVWW.NYSIFCOMXERTICERIVALASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE,IN THE EVENT OF FAILURETO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF'AGREES TO WAIVE ITS RICHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS"COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT" THAT, PRIOR TO THE DATE OF THE ACCIDENT,. THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT RIEQUIRE$THAT SUCH RIGHT OF SUBROGA BE WAIVED, THIS CEATIIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED 13Y T14E POLICY, NEW YORK STAT S NICE FUND �V DIRECTOR04SURANCE FUND UNDERWRITING Ntvr 'Workers' Yom CERTIFICATE OF INSURANCE COVERAGE srat"t Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PAR-ill.—To"be com leted b—NYS disability and Paid Family leave benefits carrier o p y 71nsumed 1a.Legal Name 8 Address of Insurmm .._� r licensed insuraagent Insured(use street address only) I b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 t c.Federal Employer Identification Number of Work Locatior,of Insuredonr or Socia!Security Number { y required ifcoverage is spec�ilcaliy limned to todain locations in New York State,ie.,Wrap-Up Policy) 823336604 2.Name and.... ....-. ...............�....__.. i Address of Entity Requesting ) g 3a Name of Insurance sur n e Carrier ante Com �� " lily equestin Proof of Coverage (Entity Being Listed as the Certificate Holder TOWN OF SOUTHOLD a�"�' 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"ta" SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/01/2023 to 12/31/2024 4. Policy provides The following benefits: ® A-Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefas only. 5. Policy covers. ® A.All of the employer's ernptoyees eligible under the NYS Disability and Paid Family Leave Benefits Law, C1 B.Only the following class or classes of employers employees: I#Jnderp4nallyof perjury,I certify ffiat I am an atuthoAzed'represontative or temsaeo agent of tha insurance carrier refeidnced above and that the named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By l (Signature&insurance carrier's authorized representative cr NYS Licensed Insurance Agent ofthat insurance carrier) Telephone Number 516- 29»B1 Name and Title P iCh rd White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 59.is checked„this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@Wcb.ny.gov or it can be mailed for completion to the Workers Compensation Board,Plans Acceptance Unit, PO Box 5200,Binghamton,NY 13902-5200. PART 2 To be completed by the NYS Workers'Com (_..-. -_. _.., ._ ............_,,�� Compensation Board(Only if Box 46,4t or 5B have been checked) State of New York Workers" � o ensation BoardAccordin to information maintained b the NS WeCom ensation Board,the above-named•named errmplayer has c.tlnnplied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers Compensation Law)vlith respect to all of their employees. Date Signed By (5ignature of Authorized NYS Workers'Compensation Beard Employee) LTelephone Number Name and Title agents Note.Onf insurance Y careers licensed to cattle NYS disability� """�"" "" ._...._ and paid family leave benefits insurance policies and NYS licensed inswance se Insurance carriers are authorized to issue Form DB-120,1 Insurance brokers are NOT authorized to Issue this form. DB-120.1 (12-21) 11 Zoho Sign Document ID:2A768FFA-BQ64L-BGW-BBAF9DCLGZ8WiJOGVYPMIDGZ9HE_NHFSM s - r Nautical;ivluseum � y mt DESIGN$DRAFTING BY: ELEMENT ENERGY LLC TO INSTALL A 15.3e KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT FLANAGAN RESIDENCE, REVIEW BY J.M.NABCEP CERTIFIED LOCATED AT 325 WELLS RD, PECONIC, NY 1 11358. a 25 ' 051 1 1 2-1 29 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. �! i Shelter Island Y` SouiFiold REVISIONS ` e Shelterlsl DESCRIPTION DATE REV SYSTEM RATING s ORIGINAL 08-30-2023 �r � -`�l � � �A� � Wades Beach Peconic N 15.39 kW DC STC 4; t'1 Jr EQUIPMENT SUMMARY Cutctiogue 38 QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES �oy8dy No: 38 ENPHA5E IQSPLU5-72-2-U5 MICRO INVERTERS r rPaj /i 'zs BAN CONTRACTOR I IRONRIDGE XRI OO MOUNTING SYSTEM �. --w..�- < . Noyack ELEMENT ENERGY, LLC. 5H EET INDEX M Jituck {� New Suffolk gllMorton �' 7470 SOUND AVE PV-I COVER "p lvationa( MATTITUCK, NY 1 1952 PV-2 SITE PLAN PROJECT LOCATION LICENSE # G74G 1-111 PV-3 ROOF PV LAYOUT LICENSE # 52G89-ME PV-4 5TRUCTUKAU DETAILS#SECTIONS PV-5 3-LINE ELECTRICAL DIAGRAM PV-G LABELS GOVERNING CODES ` O NEW � � f. 2017 NATIONAL ELECTRICAL CODE. 2020 RESIDENTIAL CODE OF NEW YORK STATE. C7 2020 FIRE CODE OF NEW YORK STATE. _; ASCE 7-1 G AND NEPA-70. UNDERWRITERS LABORATORIES(UL)STANDARDS OSHA 29 CFR 1910.249 ✓ RQcyp?��` s GENERAL NOTES PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT 00 LL.1 C) co THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE u- U Q Ln HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK w LU O AGREE THE SAME. 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED AERIAL VIEW } o r APPROVALS, PERMITS, CERTIFICATES OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, g D—/ Z AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES Z' W 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND U7 OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO Q > w U ALL RULES AND REGULATIONS OF THE RESPONSIBLE o U COMMENCING WITH WORK. Z JURISDICTION. 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I I. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR O QLn O MAINTAINING SAFETY ON THE JOB SITE DURING THE z WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS O Q N W THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND LL n CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, SPIFFY NAME 5. ALL STRUCTURAL STEEL SHALL BE AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 SPECIFICATIONS. CONSTRUCTION. COVE IN 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL N BOARD OF FIRE DRAWINGS, WHERE DIMEN51ONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND ACCORDANCE WITH N.E.C. CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES REGULATIONS 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND COMMENCING WITH WORK. CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S DRAWING SCALE CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON n .�. . SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. I V PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE EXTENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV- I RESULT OF H15 WORK. TAX MAP: 1000-075.00-OG.00-003.002 'Zoho Sign Document ID:2A768FFA-BQ64L-BGW-BBAF9DCLGZ8WiJOGVYPMI DGZ9HE_NHFSM LEGEND TAX MAP: 1000-075.00-OG.00-003.002 DESIGN 8 DRAFTING BY: IS UTILITY METER IV ELEMENT ENERGY LLC MAIN SERVICE PANEL NEW oV SUB-PANELS 0 REVIEW BY J.M.NABCEP CERTIFIED 051 112-129 CO DISCONNECT , COMBINER INVERTERS T 0 [ GND ELECTRODE 0 36'-7" REVISIONS PV MODULE 24004 j j DE5CRIPTION DATE REV �RACKING RAIL D 900 % O j RIGINAL 05-30-2023 O ATTACHMENT POINT �10' 7S 120. poll 8Qo 0 ---RAFTERS � -4—ROOF PITCH ANGLE 14 ® RUN METER /j VENT O PLUMBING VENT /,1r // 'r;r eerdwiK,a�2�/ /////// / ®SKY LIGHT ®CHIMNEY CONTRACTOR COMPOSITE SHINGLES GOOD CONDITION 181-1 ELEMENT ENERGY, LLC.I" 7470 50LIND AVE ❑ POTENTIAL VEAS NE ISSUES MATT TUCK,, NY 1 1 95 TRIM/REMOVE AS NECESSARY LICENSE# G74G I-111 jLICENSE # 52G89-ME —7-5-L 57111G h1All I ELECTRICAL SERVICE PAIIEL � �r �`-� �� C) w 1034'AS ssStP�` IsnwG ul METER : PROJECT NAME j O W I) co 2; 17-9" j w W O _Ln (Z w ((> >- I oz J z ® o z w D_ Ln O D_ Q N U m 'LJ /� O SHEET NAME �j SITE PLAN NOTE %j I .)THE ROOF SETBACK/PATHWAYSHALL NOT BE REQUIRED ON ROOF-SLOPES WHERE THE j DRAWING SCALE OPPOSING OR ADJACENT ROOF SLOPE 15 AN ACCESS ROOF IN ACCORDANCE WITH R324.G.I - = 5/411 = 11_011 EXCEPTION OF 2020 NYS RESIDENTIAL CODE. CONSTRUCTION NOTES j 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 3G•+3G•GROUIID ACCE55 TP. SHEET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. ��_ 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Zoho Sign Document ID:2A768FFA-BQ64L-BGW-BBAF9DCLGZ8WIJOGVYPMIDGZ9HE_NHFSM CONSTRUCTION SUMMARY DESIGN 6 DRAFTING BY: (38)QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES ELEMENT ENERGY LLC (DIMENSIONS: 74"X 4) .1°X 1 .3") Al REVIEW BY J.M.NABCEP CERTIFIED (38) ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTER50° 051 1 12-123 (G8)ATTACHMENT POINTS @ G4'I O.C. MAX. (279.9) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. /7 REVISIONS ER) ROOF TYPE: ASPHALT SHINGLE (SINGLE LAY VON, DESCRIPTION DATE REV /+:/ / ORIGINAL 08-04-2023 CONSTRUCTION NOTES �� j 24po Q Y 9p°c WITHLTHE MANUFACTURERI5 INS ALLATIION IA 5TORUDCTIONS.ANCE 3280 a45'PT H /'� %P 2'p° D 720° 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH /n, �n 180°ASO° MINIMUM NEMA 3R RATING. T j ® 0 ® ® ® f� ® / 3'-G2° C, 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE .jF. , t� FIELD VERIFICATION. ARRAY#2 0 0 22 MODULES 450 PITCH 0 0 0 0 0 148°AZIMUTH y ® ® 0 0 0 CONTRACTOR m 0 m 0 0 ELEMENT ENERGY, LLC. 7470 SOUND AVE ® MATTITUCK, NY 1 1952 A Y#3 LICENSE # G74G 1-111 LICENSE # 52@89-ME :58* MODULES 45°PITCH AZIMUTH OF NSlgrE PAf1EL ,r,7 afl A �r 8 �enr�G.rlD ��ittiS�j * V c 9 IIRN PVA 1 '1, _•_ '•I�•vY--ti—e:. rte, sstiC>N��, sn1IG unuTr h1ETER /j ' B PROJECT NAME e OLL_ lL I C�l 00 zZ/ w w O ® D-/ W (s) >- 0 — zW U Ln O LEGEND o Q N (� m 'u EXISTING O UTILITY�MA NS RVICEPANEL EE /1 1� j ®NEW PV UB-PANELS A/C DISCONNECT COMBINER DELECTRODE SHEET NAME INVERTERS GNELECTRODE j PV MODULE FV LAYO U T —RACKING RAIL O ATTACHMENT POINT j ---RAFTERS DRAWING SCALE PROOF PITCH ANGLE AR Y#4 SUNRUN METER 5/6411 = I 1-011 5 MODULES VENT 181 PITCH 6'x 148°AZIMUTH 3G'GROJIID ACC S TYP. O PLUMBING VENT I .)THE ROOF SETBACgPATHWAY SHALL NOT BE ®SKY LIGHT REQUIRED ON ROOF-SLOPES WHERE THE SHEET NUMBER OPPOSING OR ADJACENT ROOF SLOPE 15 AN ®CHIMNEY ACCE55 ROOF IN ACCORDANCE WITH R324.G.I COMPOSITE SHINGLES FV-3 GOOD CONDITION EXCEPTION OF 2020 NY5 RESIDENTIAL CODE. TAX MAP: 1000-075.00-0G.00-003.002 ❑POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY Zoho Sign Document ID:2A768FFA-BQ64L-BGW-BBAF9DCLGZ8WIJOGVYPMI DGZ9HE_NHFSM ITEM DESCRIPTION ARRAYS#1-2 ARRAY#3 ARRAY#4 DE51GN B DRAFTING BY: LOAD CALCULATION ARRAY#I ARRAY#2 AP RAY ARRAY#4 RB Rid e Bearn/Boarci 2"X 1 2" D. FIR 2"X 12" D. FIR 2"X 12" D. FIR ELEMENT ENERGY LLC (R) Rafter 2"X 10" D. FIR I G" O.0 2"X 12" D. FIR I G" O.0 2"X 8" D. FIR I G" O.C. REVIEW BY J.M.NABCEP CERTIFIED MODULE WEIGHT(Lbs) 48.4 48.4 48.4 48.4 (D) Deckin 5/8" PLYWOOD 5/8" PLYWOOD 5/8" PLYWOOD 051 1 12 129 #OF MODULE5 8 22 3 5 (P) Pitch 45' 45' 1 8° (J) Ceilincl Joist 2"X 8" D. FIR I G" O.C. 2"X 8" D. FIR A I G" O.C. 2"X 8" D. FIR I G" O.C. REVISIONS TOTAL MODULE WEIGHT(Lbs) 387.2 1 OG4.8 145.2 242.0 (C) Collar Ties 2"X G" D. FIR 48" O.C. 2"X G" D. FIR P 48" O.C. I NIA DESCRIPTION DATE REV TOTAL LENGTH OF RAIL(Ft) 55.4 273.2 20.8 34.7 H Horizontal Span of R 1144" MAX. 1 19" MAX. G3" MAX ORIGINAL 08-30-2023 RAIL WEIGHT PER FOOT(Lbs) O.GB O.G8 O.GB O.GB TOTAL RAIL WEIGHT(Lbs) 37.7 185.8 14.1 23.G #OF 5TRANDOFFS 12 G2 G 8 WEIGHT PER 5TRANDOFF(Lbs) 2 2 2 2 (RB TOTAL STANDOFF WEIGHT(Lbs) 24 124 12 1 G (w TOTAL ARRAY WEIGHT(Lbs) 448.9 1374.6 171.3 28 I.G (D) POINT LOAD(Lbs) 37.4 22.2 28.G 35.2 i (Ri (Rel CONTRACTOR f TOTAL ARRAY AREA(5q Ft) 171.3 471.0 G4.2 107.1 (D) ELEMENT ENERGY, LLC. 7470 SOUND AVE ARRAY DEAD LOAD(1-1,5/5q Ft) 2.G 2.9 2.7 2.G MATTITUCK, NY 1 1952 WIND DESIGN SUBJECT TO DAMAGE FROM cP LICENSE # 6746 1-HI GROUND SEISMIC WINTER ICE BARRIER AIR MEAN (C' (� LICENSE # 52689-ME SNOW p¢edy Topographic Special Windbome DESIGN Fromm DESIGN UNDERLAYb7ENT FLOOD FREEZING ANNUAL S LOAD' peed(mphef/e� wind debris cATEGORYt Weathering' fine Termite' TEMpa REQUIREDt' HAZARDSS INDE%1 TEMPI region' zone'" depths' O� IVEJ'V 20 140 NO NO NO B SEVERE 3 FT 15°F YES Z EMA 599 51"F ��pIJ A G, �0'F' 4nnhtANUALJ DESIGN CRITERIA- (H (H) - .�CCJ_ lltit`��ti-,� Gdt� t Ir Indoor Heating (J) (J) Elevation Latitude Winter Summer Altitude desiDesign temperature UJ C1 ,L,_ hearing cooling correction on tactor temperature cooling SG temperature difference Oft ''=wtiLt 108 FT 41`N 15`F 85'F 1.00 10'F 75`F 55"FBOJ* 103.4A3 Cooling Coincident Dally Winter Summer <(. Wind Wind [ARRAYS #1-3] [ARRAY#41 Rp SMS% - temperature difference velocity velocity heating cooling wet bulb range humidity humidity 11'F 15 MPH 7.5 MPH 72-F MEDIUM(M) 40% 32 GR @50%RH PROJECT NAME For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL n 0 W Q 00 (� U Q Ln a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth Z O strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as LL-1 W _ determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. } b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. (n W (� C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. Q J d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined -1 _J z on asite-specific basis in accordance with Section R301.2.1.4. (n Q � " e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York MODULE MOUNTING CLAMP U State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also � QD see Figure R301.2(1).] SOLAR.MODULE (n � O N f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. 5TAINLE55 5TEEL 318" Z Ln g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New BOLT AND NUT U York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the J rV1 JJ_J Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: LL J (L i.The accompanying Flood Insurance Rate Map(FIRM), NRJDGE ALUMINUM RAIL ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. ALUMINUM"L"BRACKET SHEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ALUMINUM FLASHING effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." STRUCTURAL 1. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method A5PHALT 51-IINGLE ROOF (Base 32°F)." 5T EL LAG BOLT WIT It. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 2 112"MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"In this part of the table. PENETRATION SEALED DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR 5E17EPJ m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the AS NOTED table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or lb from ACCA Manual J or established criteria determined by the jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet SHEET NUMBER (•) See Figure R301.2(4)B. PV-4 TAX MAP: 1000-075.00-OG.00-003.002 MOUNTING DETAIL n Zoho Sign Document ID:2A768FFA-BQ64L-BGW-BBAF9DCLGZ8WiJOGVYPMIDGZ9HE_NHFSM DESIGN 4 DRAFTING BY: 50LAP.ARRAY ON MAIN HOUSE 15.35 kW ELEMENT ENERGY LLC (38)QCELL Q.PEAK DUO-15LK ML-G 10+405 WATT PV MODULES REVIEW BY J.M.NABCEP CERTIFIED (2)STRINGS OF(13)MICRO-INVERTERS 4(1)STRING OF(1 2)MICRO-INVERTERS 051 1 1 2-1 29 '(3)STRINGS TOTAL OLAR MODULE TYPICAL TO UTILITY GRID REVISIONS STRINGS #1 -2 DE5CPJPTION DATE REV ENPHA5E L1 L2 N q- - - - - - - - - - - - - ORIGINAL 08-30-2023 --------------------- ---------------- -- G G G G G G G G G G G G G I __ BRANCH E51-DIRECTIONAL TERMINATOR o UTILITY METER TYPICAL I-PHASE,240 V �- ------------------- G G G G G G G G G G G G G I L1 L2 N POINT OF INTERCONNECTION PER NEC 240.21(5)(1)4 690.64(A) I STRING #3 LENGTH OF TAP CONDUCTORS SHALL NOT EXCEED 10 FT CONTRACTOR I - - G G G G G G G G G G G MAIN SERVICE DISCONNECT ELEMENT ENERGY, LLC. _-__� �____� -__-� ��___� ��--_ ____� ��_-_+ __- � V.200A 7470 SOUND AVE 1 ENPHA5E BRANCH MICRO-INVERTER MATTITUCK, NY 1195 CIRCUIT CABLE TYPICAL ENPHASE 108PLU5-72-2-US 240 VAC. 1.21 A 97%CEC-WEIGHTED EFF. LI NS 67461-111 AC D15CONNECT NEMA G.UL LISTED L1 L� LICENSE # 52389-ME TYPICAL L2 L2 I I SQ D 1)223NRB 240 VAC.60 A NEMA 3R.UL(2)60 A FUSES TED L2 L2 � (�'� �A El,Y�� 4 N L �I N L .I };. �� A e,cc 0A 20A GOA L1 L1 I L2 L2 �erv�L.rl� �iln jrG. $ I W I MAIN SERVICE PANEL 1I N N I-PH.3-W •+�!: }i'RY1 v •- - -- 240 VAC 1D3.4A'3 Ir- -- G ---_- G --------------------------------------------------- 200A iO I AC COMBINER BOX 4 240 VAC.80 A I4EMA 3R.UL U5TED L (3)20 A DOUBLE POLE BREAKERS I I I I EXI5TING GROUNDING PROJECT NAME I I I I ELECTRODE SYSTEM CZ I I -----------U i C) w C) Co I i 'L U Q Ln w z Q 6� w L-------------------------------- -- ------------ ' i D a-/ - WIRE CONDUIT SCHEDULE Q w >- CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPEFCONDU CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% n/ z I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION 51ZE QUANTITY INSULATION (CU/AL) SIZE TEMP DEBATE DISTANCE J -[ 310.)5(5)(3) 310.)5(5)(2a)/(3c) O z W ' ` I INVERTERS COMBINER PANEL AWG#12 1 6 0.8 U5E-2/PV Wire AWG#8 1 BARE CU I" 55QC 0.84 90 FT 2.84% p < > J LUQz 2 COMBINER PANEL AC D15CONNECT AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 CU P, 45QC 0.95 25 FT 0.73% 0 3 AC DISCONNECT MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 459C 0.95 10 FT 0.24% Q (v w m � ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. [NEC G90.8(5)(I)J: (Isc)'(#of stnngs)'(I.5G)= 19.GG A Modules per String ,3 MAX3-LINE DIA. 3.)WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY AWG#12, ampacity'Temp Derate= 20.1 G A TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. 20.1 G A>19.GG A,therefore DC wire size Is valid. Modules per Inverter 1 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL #2 Inverter Output Wire Ampacity Calculation Number of Inverters 38 COMPLY WITH NEC 110.26. Inverter Max Amperage output' (1.25) = 57.48 A Record low temp -I OQC 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL AWG#G,am acct (Tem Derate)'(Conduit Fill Derate)= 71.25 A o FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE550PIE5 TO FULFILL p y p Voc Temp Coefficient -0.24%/-C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 71.25 A> 57.48 A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. Inverter Max Amperage output'(1.25) = 57.48 A O eratin Current 10.8 A N .T.5. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G,ampaclty'(Temp Derate)'(Condult fill Derate)= 71.25 A Operatinq Voltacle 37.4 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A> 57.48 A,therefore AC wire size is valid. Max.System Voltage 49.G V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEER LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR IL5CO GBL-4DBT LAY-IN LUG. Max AC Out ut Current 57.48 A 10.)THE POLARITY OF THE GROUNDED CONDUCTORS I5(posltive/necgative) PV-5 OR O eratin AC Volta e 240 V 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1 000-0755.00-OG.00-003.002 • Zoho Sign Document ID:2A768FFA-BQ64L-BGW-BBAF9DCLGZ8WiJOGVYPMIDGZ9HE_NHFSM SERVICE METER O O DESIGN 8 DRAFTING BY: _ _ __ _ INSTALLATION NOTE ELEMENT ENERGY LLC SOLAR PV SYSTEM 1 PHOTovOLT I a • • • ` ( I ) ALL LABEL SHALL BE INSTALLED IN REVIEW BY SM.I NZBC29 CERTIFIED EQUIPPED WITH I!SOLAR BREAKER • • ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® OPERATING VOLTAGEREQUIREMENTS. REvisioNs OPERATING DESCRIPTION DATE REV _ (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 08-30-2023 MAX SYSTEM VOLTAGE VDC i - --� REQUIRE FIELD VERIFICATION. SOLAR AC LOAD CENTER- OUT51DE p �DONOTRELflCATETHiS: ,• g OVERCURR�ITDEnCE (3) LABELS, WARNINGS) AND MARKING 0 TURN RAPID SHtrrpowNSWITCH ro 0 SHALL BE IN ACCORDANCE WITH NEC THE°OFF•POSMON To SHUT DOWN I 1 0.2 1 (D). i PV SYSTEM AND REDUCE Y — ` SHOCK HAZARD INTHEARRAY AC DISCONNECTI-11 �,mTmCAUTION5w� (4) THE MATERIAL USED FOR MARKING FROM= MOASSHMCES„ MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - INSIDE O ® "'""E'er��`� COMPLIANCE WITH NEC 1 10.2 I (B)(3). coNTRAcroR PV (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLC. 4 7 /—a\ 1 1 NEGRE �/ G m Y 7470 SOUND AVE O O O SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 1 95 THIS���FID BYMUI.TIPLE DUAL POWER SUPPLY SOURCES.TOTALRAMNGOFALL �� COMPLIANCE WITH NEC 690.3 I LICENSE# G74G 1-111 OVERCURRENTDEMCES,EXCLUDING ' SOURCES:UTILITYGRID LICENSE # 52G89-ME MAIN SUPPLYOVERCURRENT AND PV SOLAR DEVICE,SHALL NOT EXCEED ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING AMPACIIYOFBUSBAR - I or- Nsly y VIM �eY�nGrO �itti �"��l — D A- N I N THIS SERVICE METER C arj a u IS ALSO SERVED BY A ` m s- j ELECTRIC SHOCK HAZARD I PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM TERMINALS ON THE UNEAND COMBINER PANEL LOAD SIDES MAYBE ENERGIZED DO NOT ADD LOADS CONDUIT - OUTSIDE 5UILDING —.IN THE OPEN POSITION PROJECT NAME 1/1/A' N 1 • ' Q ,n DUAL POWER SUPPLY LLJ W O ISOURCES:UTIUTY GRID AND . ^/ PV SOLAR ELECTRIC SYSTEM`I } C) CZ- MAIN SERVICE PANEL- OUTSIDE 5 A CAUTION SOLAR CIRCUIT L Z O i z LLJ ACAUTION_-___ o Q > U SOLAR REGI IC SYSTEM CONNECTED UI w z O • • • ` o z O 6 • o Q N W MAIN SERVICE PANEL - INSIDE EFIEVAl RN NG �• LL- POWER LPOWER SOURCE �I OUTPUT CONNECTION e SHEET NAME ® O DO NOT RELOCATE THIS 11 I OVERCURRENT DEVICE -- LABELS AC DISCONNECT/BREAKER DRAWING SCALE 000 ® N .T.S . 5HEET NUMBER PV-6 TAX MAP: 1000-075.00-OG.00-003.002 Zoho Sign Document ID:2A768FFA-BU64L-6UW-SBAF90CLUZ8WIJOUVYPMIDUZ9HE_NHFSM Town of Southold August 30th, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Flanagan Residence, 325 Wells Rd Peconic NY 11958 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.9 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, OF N EIV Gennaro Anthony Giustra. P.E. + 0 A � 0 Great Eastern Services, Inc. . PO Box 240 r �. � rc, 24 Harvey Rd Riverhead, NY 11901" Mobile: 631.235.0189 ' f Email: jerrygiustra@gmail.com Zoha+Sign Document ID:2A768FFA-QLI7HKS6MXYKUBZPKLWFROHICTBBTTESWIFLOSWMLUY 6— S� C' SCOPE OF WORK �.;y. ._ 'cf3::.., •�' F. „�,3� © `aaFy...,.'s.s ._.-_ r�.-1'P 6 .,�,� ,.,' 'i DESIGN 2 DRAFTING BY: .� dt Hotton Point Li Ifiitiouse: �, a b1 , 'NauticaldMu'seom;®`° +;f,' k Shelterlsland ELEMENT ENERGY LLC as t TO INSTALL A 15.39 KWDC PV 5Y5TEM AND A 20 kWhAC BATTERY ENERGY STORAGE SYSTEM AT FLANAGAN RESIDENCE, Hei hts ,�f,•{{j rC • •,•. s t;. ;, ,' p `"'• I I' 9 <, , REVIEW BY J.M.NABCEP CERTIFIE T:'.c -' - ". .•ant3',r'': 6 ~ •'�y.f- +iY ! 051 1 1 2-129 LOCATED AT 325 WELL5 RD, PECONIC, NY 1 1956. 4, THE POWER GENERATED BY THE PV SYSTEM AND BATTERY ENERGY STORAGE SYSTEM WILL BE INTERCONNECTED WITH �w Shelter Island e THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. ■w �$ -p■w■p,,//ww,,� f Southold fT, REVISIONS A M 9•■' E 1 ` r^; - .' >k t.. , Shelter(— SYSTEM KATI NG , DESCGINALRJP DATE REV ''� ...z� / V� aT� � ORIGINAL 03-0I-2024 ,� 'Z, L.. -�?a a flr Wades-Beach t,am 20 kW AC STC BE55 SYSTEM fco c/J� 1 5.39 KW DC 5TC PV SYSTEM EQUIPMENT SUMMARY I UNIT OF ENPHA5E ENCHARGE 20KW BATTERY ENERGY STORAGE // a 38 QCELL Q.PEAK DUO BLK ML-G 10+405 WATT PV MODULES �� � G � 38 ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS wicnogue // - No I IRONRIDGE XR,100 MOUNTING SYSTEM fJ aof°°`ke'y S I—I EET INDEX ` zb BA CONTRACTOR ELEMENT ENERGY, LLC. PV-I COVER Ma[rt'>� B 'N -Suffolk o �liaa th ; PV-2 SITE PLAN //f 7470 SOUND AVE PV-3 PLAN l� t`. :, nrationa('= MATTITU CK, NY 1 105 PV-4 STRUCTURAL DETAILS PROJECT LOCATION LICENSE# G74G 1-11I PV-5 BATTERY PLAN LICENSE# 52G65-ME PV-G ELECTRICAL DIAGRAM PV-7 LA5EL5 GOVERNING CODES OF NE`q/ �P pg0AGiG0 2017 NATIONAL ELECTRICAL CODE. * � S'A 2020 RESIDENTIAL CODE OF NEW YORK STATE. 2020 BUILDING CODE OF NEW YORK STATE. n ° W 2020 FIRE CODE OF NEW YORK STATE. Z A5CE 7-1 G AND NFPA-70. N — - C� UNDERWRITERS LABORATORIES(UQ STANDARDS �O 703443 0511A 29 CFR 1910.2G9 ARQFESS►ONP� GENERAL NOTES PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT O THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE u AHIMSELF GREE THEISAME o E INTENT OF THESE PLANS AND MAKE WORK AERIAL VIEW LU U co z 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED >- o LLJ O APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP � w to ,- INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM IY -1 z CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, g AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. z w COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES O Q � U 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND Ln ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO o Q Ln z0 COMMENCING WITH WORK. w z N JURISDICTION. to m LU 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I I. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR O U- WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE n THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND a- CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. TH15 SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, 5HEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY FABRICATED AND INSTALLED AS PER LATEST A.I.5.0 SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT COVE SPECIFICATIONS. CONSTRUCTION. 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE L DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING r UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING c a NYS CODES REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND ; 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN t CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. K 1. DRAWING SCALE 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THI5 1iWAY 1 Q L CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON 2024 u 8. THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. ' " • •`� SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE . AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED F:.- 14 PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE EXTENSIONS TO THI5 PROJECT LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE 5HEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO HI5 WORK, OR DAMAGED AS FINAL PAYMENT. PV- I I RESULT OF HIS WORK. TAX MAP: 1000-075.00-OG.00-003.002 Zoho Sign Document ID:2A768FFA-QLI7HKS6MXYKUBZPKLWFROHICTBBTTESWIFLOSWMLUY e LEGEND DESIGN i DRAFTING BY: -- ®EIDSTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL REVIEW BY J.M.NABCEP CERTIFIE NEW PV SUB—PANELS 05)I12-129 A/C DISCONNECT COMBINER - 0o INVERTERS ® G+D ELECTRODE __-----_-.-_—_--- REVISIONS Q 210o DESCRIPTION DATE REV PV MODULE 4 —RACKING RAIL / ORIGINAL 05-0I-2024 240. o ATTACHMENT POINT i D 4900 2, o F ---RAFTERS % ' 7200 (—ROOF PITCH ANGLE // �§ 18'�I I" 80o SDo ®SUNRUN METER VENT OPLUMBING VENT ®SKY LIGHT ®CHIMNEY CONTRACTOR COMPCONDITIONIING 18 I I„ ELEMENT ENERGY, LLC. VE POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY MATTI O C O NY I5UNDA 95 ®u,nuTY METER LICENSE # G74G I-HI ®MAIN ELECTRICAL PANEL / ©PV AC DISCONNECT LICENSE# 52G89-ME i' �� 3 w G"x 3G"GROUND ACCE55 TYP. �P(� O CY O ISTING MAIN ELECTRICAL SERVICE PANEL � � � G 0 � a U Tr E) BOA �0344. NEW PV AC D15CONNECT / ROFESStONP�' PROJECT NAME 15TWG UTILITY METER NEW BATTERY ENERGY STORAGE //'fi / cz 5Y5TEM UNIT WITHIN THE j // BATTERY ENCL05URE IN THE BASEMENT / Uj w U LU C, In Q C) — / f N LU onz z w - /,%/ % o g mLLJ (- `L 0 D OSHEET NAME SITE PLAN 'NOTE 1.)THE ROOF 5ETBACK/PATHWAY SHALL NOT BE REQUIRED ON ROOF-SLOPES WHERE THE OPPOSING OR ADJACENT ROOF SLOPE 15 AN DRAWING 5CALE ACCESS ROOF IN ACCORDANCE WITH R324.G.1 EXCEPTION OF 2020 NYS RESIDENTIAL CODE. 5/G411 = I 1-011 CONSTRUCTION NOTES 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, SHEET NUMBER 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. PV-2 3.)ALL LOCATIONS ARE APPROXIMATE AND R EQUIRE FIELD VERIFICATION. 4.)THE BATTERY ENCLOSURE SHALL BE COMPLIANT WITH R327 OF 2020 NYS RESIDENTIAL CODE TAX MAP: 1000-075.00-OG.00-003.002 Zoho Sign Document ID:2A768FFA-QLI7HKS6MXYKUBZPKLWFROHICTBBTTESWIFLOSWMLUY LEGEND DESIGN 4[)RAFTING BY: - ®c EXISTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL Al REVIEW BYO.51 INZBCZPSCERTIPIE NEW PV SUB-PANELS Do A/C DISCONNECT -- COMBINER INVERTERS 1n. / ® REVISIONS GND ELECTRODE j/ j 0o DESCRIPTION DATE REV QPV MODULE f i ji/ 2400 49 o ORIGINAL 05-01-2024 RACKING RAIL O ATTACHMENT POINT I G 7? o C 45°PITCH /§j 1,50o O ---RAFTERS 328°AZIMUTH CIO. PROOF PITCH ANGLE 0 0 0 �' 3'-Gz" S . �SUNRUN METER _ OPLUMBING VENT A' 0 ® m fa 22 4 O PITCH ® ® ®SKY LIGHT 148°AZIMUTH CONTRACTOR ®CHIMNEY T Fa 0 0 0 ®COMPOSITE CONDITION SHINGLES m ELEMENT 7470 50UND AVE GOOD CONDIRON i POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY m MATTITUCK, NY 1 1952 @U ILITY METER j / LICENSE # G74G I-HI ®MAIN ELECTRICAL PANEL / LICENSE# 52G89-ME ©PV AC DISCONNECT 3G"x 3G"GROUND ACCESS TYP. 5TING MAIN ELECTRICAL SERVICE PANEL / JANEWyA G'G OLEA6 - wE) • 2 NEW PV AC DISCONNECT / / �O 103443 / ARO�SSIONP� ISTING UTILITY METER NEW BATTERY ENERGY STORAGE T SYSTEM UIJIT WITHIN THE BATTERY ENCLOSURE IN THE i j� PROJ C NAME BASEMENT 0 Lu o - //i z w 0 3 m o 'NOTE o CZ 1.)THE ROOF 5ETBACK/PATHWAY SHALL NOT BE REQUIRED ON ROOF-SLOPES WHERE THE O OPPOSING OR ADJACENT ROOF SLOPE 15 AN ACCESS ROOF IN ACCORDANCE WITH R324.G.I SHEET NAME EXCEPTION OF 2020 NYS RESIDENTIAL CODE. CONSTRUCTION SUMMARY PV PLAN (38) QCELL Q.PEAK DUO BLK ML-G 1 0+ 405 WATT PV MODULES (DIMENSIONS: 74"X 4 1.1"X 1.3") (38) ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS (G8)ATTACHMENT POINTS @ G4"O.C. MAX. DRAWING SCALE (279.9) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. ROOF TYPE: ASPHALT SHINGLE (SINGLE LAYER) 5/G411 = I 1-011 CONSTRUCTION NOTES 1 .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION IN5TRUCTION5. 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH SHEET NUMBER MINIMUM NEMA 3R RATING. FV_3 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000-075.00-06.00-003.002 Zoho Sign Document ID:2A768FFA-QLI7HKS6MXYKUBZPKLWFROHICTBBTTESWIFLOSWMLUY LOAD CAL�:ULATIONI ARRAY#I ARRAY#2 ITEM DESCRIPTION ARRAYS#I-2 RB Rld e Bea m/Board 2"X 1 2" D. FIR DESIGN s DRAFTING ELEMENT ENERGY LLC MODULE WEIGHT(Lbs) 48.4 48.4 R Rafter 2"X 10" D. FIR I G"O.0 REVIEW BY (D) Deckn 5/8" PLYWOOD 051 1 N2-1 2 CERTIFIE 00 #OF MODULE5 1 G 22 P) Pitch 45' J) Cellin J015t 2"X 8" D. FIR I G"O.C. REVISIONS TOTAL MODULE WEIGHT(Lbs) 774.4 IOG4.8 C) Collar TIeS 2"X G" D. FIR 48"O.C. 0E5CRIPTI0N DATE REV TOTAL LENGTH OF RAIL(Ft) 110.5 273.2 H) Horizontal Span of R) 144"MAX. ORIGINAL 05-0I-2024 RAIL WEIGHT PER FOOT(Lbs) O.GB 0.G8 TOTAL RAIL WEIGHT(Lbs) 75.3 155.5 (RB) #OF 5TRANDOFF5 24 G2 (R) WEIGHT PER 5TRANDOFF(Lbs) 2 2 (D) TOTAL STANDOFF WEIGHT(Lbs) 48 124 TOTAL ARRAY WEIGHT(Lbs) 897.7 1374.E POINT LOAD(Lbs) 37.4 22.2 CONTRACTOR TOTAL ARRAY AREA(Sq Ft) 342.G 471.0 ELEMENT ENERGY, LLC. ARRAY DEAD LOAD(Lbs/Sq Ft) 2.G 2.9 7470 SOUND AVE MATTITUCK, NY I 155 GROUND WIN SEISMIC D DESIGN SUB WINTER ICE BARRIER AIR MEAN SUBJECT TO DAMAGE FROM LICENSE # G74G I-HI (P SNOW DESIGN DESIGN UNDERIAYMENT FLOODFREEZING ANNUAL (C) LICENSE # 52G89-ME LOAD° Speed° Topographic Special Windborne CATEGORY' Frost TEMP` REQUIREEP HAZARDS° INDEXi TEMPI (mph) effectsk wind region debris zone'" Weathering' line depth" E VY Termite` 20 140 NO NO NO B SEVERE 3 FT HA I3°F YES ZONEAX 599 5 I'F ��OF NE]y YO MANUAL J DESIGN CRITERIA' �P ap¢O A GZG ,per r Indoor Elevation Latitude Winter Summer Altitude correction Factor design Design temperature cooling Heating temperature (H) 2 2 heating cooling tempera difference ture W Y 703445 108 FT 41'N 15'F BG'F 1.00 70'F 75'F 55'F A'40�SS%pNPv Wind Wind Coincident Daily Cooling temperature difference velocity velocity et bulb Daily range humidity Summer humidity - [�[ PROJECT NAME heating wet I 1 �ROOF FRAMING DETAIL 15,F )5 MPH 7.5 MPH 72'F MEDIUM(M) 40% 32 GP @5095 PH 0 For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. w UCID I— Z C� Ln a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth } LLJp O strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as _ determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. MODULE MOUNTING CLAMP p� w } b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction J Z shall fill in the frost line depth column with the minimum depth of footing below finish grade. Z w C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. SOLAR MODULE 00 Q ? U d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined STAINLESS STEEL 3/8° Q N O on a site-specific basis in accordance with Section R301.2.1.4. LU Z W BOLT AND NUT e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York N g � State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also 0 L, IL see Figure R301.2(1).] p f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. _ � g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New NIRIDGE ALUMINUM RAIL York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the ALUMINIUM"L"BRACKE f Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: L The accompanying Flood Insurance Rate Map(FIRM), 5HET NAME ii.Flood Boundary and Floodway Map(FBFM),and ALUMINUM FLASHING III.Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. STRUCTURAL DETAILS h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall fill in this part of the table with"NO." F. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) ASPHALT SHINGLE ROOF value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)" 5/1 G"x G"STEEL LAG BOLT LE55 13OL5TAIT WITH j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method MIN(Base 32'F)." PENETRATION 5EAL DRAWING SCALE D k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the WITH GEOCEL 4500 jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) I . I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with I �t "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J or established criteria determined by the SHEET NUMBER jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at \/_4 elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. MOUNTING DETAIL n I v 4 (`) See Figure R301.2(4)B. TAX MAP: 1000-075.00-OG.00-003.002 Zoho Sign Document ID:2A768FFA-QLI7HKS6MXYKUBZPKLWFROHICTBBTTESWIFLOSWMLUY LEGEND DESIGN 4 DRAFTING BY: o DOSTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL REVIEW BY J.M.NABCEP CERTIFIE NEW PV SUB-PANELS 0511I2-129 A/C DISCONNECT --- COMBINER INVERTERS 2) GND ELECTRODE REVISIONS 0E5CRIPTI0N DATE REV =PV MODULE OPJGINAL 05-01-2024 RACKING RAIL 0 ATTACHMENT POINT ---RAFTERS -*—ROOF PITCH ANGLE ffjSUNRUN METER 15TING CONCRETE WALL ®VENT 0PLUMBING VENT ®SKY LIGHT CONTRACTOR CHIMNEY .d °a ° ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. GOOD coNolnoN 7470 SOUND AVE POTENTIAL SHADING ISSUES 3n 3� I)SONNEN SONNENCORE+ 20KW BESS UNIT ❑TRIM/REMOVE AS NECESSARYMATTITUCK, NY 1 195 74 7 ©uTIUTY METER LICENSE # G74G I-HI 2'-1 2" /8"TYPE X GYPSUM BOARD OR EQUIVALENT SP MAN ELECTRICAL PANEL LICENSE# 52G89-ME ° ©PV AC DISCONNECT a ,C�OF NEW Y ° P oa O KOPOSED FIRE-RATED BESS ENCLOSURELU a ZF _ =2 ( O 1034A tv GONSTRUGTION SUMMARY ARo�SStoNA� 3OG8 RFGO STEEL JAMBS 90 MIN MYLAR METAL FIRE DOOR (1) UNIT OF SONNEN 50NNENCOPF-+ 20 KWH BATTERY PROJECT NAME ENERGY STORAGE UNIT(DIMENSIONS: G3.28"X 27.08"X 1 3.65") IN THE BATTERY ENCLOSURE WITH REQUIRED SIDE OZ/ - CLEARANCE OF G-INCHES U- CONSTRUCTION NOTES w LU co 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE Lj w Q m TAI WA WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS. — 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 0� w N z MINIMUM NEMA 3R RATING. g � z 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE O Q � CU FIELD VERIFICATION. z Ln 4.)THE CONDUIT/WIRE RUNS TO THE EXISTING MAIN o z N O TAIRWAY ENTERING BASEMENT SERVICE PANEL AND TO THE PLP IN PVC CONDUIT INSIDE 0 m OF THE EXISTING BASEMENT AND THEY SHALL BE LOCATED (O INDOORS. EL/ 4M 5.)THIS BESS SYSTEM INSTALLATION IS COMPLIANT WITH THE SECTION R327 OF THE INTERNATIONAL RESIDENTIAL CODE, AS AMENDED BY THE NEW YORK STATE UNIFORM 51-I=ET NAME CODE. ` G.)THE SYSTEM SIDE OF THE BATTERY AREA IS PROTECTED BY 8"TYPE X GYPSUM BOARD OR EQUIVALENT. BATTERY PLAN 7.)THE SMOKE DETECTOR OR HEAT DETECTOR SHALL BE INSTALLED AND THE BESS SYSTEM SHALL TRANSMIT AN ALARM SIGNAL VIA MOBILE PORTAL OR THE SMOKE AND/OR HEAT ALARM/DETECTOR IF POTENTIALLY HAZARDOUS TEMPERATURES OR OTHER CONDITIONS DRAWING SCALE [FLOOR PLAN OF Tt1E BESS ENCLOSURE LOCATED IN THE BASEMENT] SUCH AS SHORT CIRCUITS, OVER VOLTAGE OR UNDER I /211 = I 1_01 VOLTAGE ARE DETECTED. 8.)THE REQUIREMENT FOR A MINIMUM OF 3-FEET CLEARANCE IN FRONT OF THE BATTERY UNIT IS ENSURED WHEN THE BATTERY ENCLOSURE DOOR IS IN THE OPEN POSITION,THUS COMPLYING WITH SAFETY STANDARDS 5HEET NUMBER — AND PERMITTING MAINTENANCE ACCESS AS STIPULATED. PV-5 TAX MAP: 1000-075.00-OG.00-003.002 Zoho Sign Document ID:2A768FFA-QLI7HKS6MXYKUBZPKLWFROHICTBBTTESWIFLOSWMLUY ELECTRICAL NOTES GENERAL NOTES DESIGN s DRAFTING BY: 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER 1,) THE BESS PROVIDES MONITORING AND ELEMENT ENERGY LLC - NRTL, AND LABELED FOR ITS APPLICATION. BALANCING CELL VOLTAGES, CURRENTS, REVIEW BY J.M.NABCEP CERTIFIE SOLAR ARRAY ON THE PAIN HOUSE 10.125 kW 2.) ALL CONDUCTORS SHALL BE COPPER, RATED AND TEMPERATURES WITHIN THE 051 1 1 2-1 20 (25)OCELl: O.PEAK DUO ELK YL-G1Ot 405W PV MODULES FOR 600 V AND 90°C WET ENVIRONMENT. MANUFACTURER'S SPECIFICATION THROUGH WEB (1)STRHG OF(1a)MICRO-INVERTERS s(1)STRING of(12)MKxalRvvlms VOOULE rIWAL 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON AND MOBILE APPLICATIONS. REVISIONS ROOFTOPS SHALL BE ROUTED DIRECTLY 2.) THE HEAT DETECTOR OR HEAT ALARM SHALL STRING #2 TO, AND LOCATED AS CLOSE AS POSSIBLE TO BE INSTALLED AND INTERCONNECTED WITH De5CPJPrION DATE REV _ _ _ _ _ THE NEAREST RIDGE, HIP, OR VALLEY. SMOKE ALARM AND THE BESS SYSTEM SHALL ORIGINAL 05-01-2024 MODULE INFO _---------- _ _ _ _ _ _ _ °O"`¢ 4.) WORKING CLEARANCES AROUND ALL NEW AND TRANSMIT AN ALARM SIGNAL VIA MOBILE MODEL PART NUMBER - + 1 ,m,raL1Qt EXISTING ELECTRICAL EQUIPMENT SHALL PORTAL OR THE SMOKE AND/OR HEAT -------- COMPLY WITH NEC 110.26. ALARM/DETECTOR IF POTENTIALLY HAZARDOUS VOC 45.31 V i 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT TEMPERATURES OR OTHER CONDITIONS SUCH AS VMP 38.48 V I OF SYSTEMS. CONTRACTOR SHALL SHORT CIRCUITS, OVER VOLTAGE OR UNDER ISC 11.11 A STRING #3 - FURNISH ALL NECESSARY OUTLETS, SUPPORTS, VOLTAGE ARE DETECTED. I - FITTINGS AND ACESSORIES TO FULFILL IMP 10.65 A I � - - - - - - - - 3.) CONDUIT AND CONDUCTORS SPECIFICATIONS STC RATING 405 W APPLICABLE CODES AND STANDARDS. ARE BASED ON MINIMUM CODE REQUIREMENTS STC RATING 307. W 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND ARE NOT MEANT TO LIMIT UP-SIZING AS I n..a aw,o AND CONDUITS ARE NOT SPECIFIED, REQUIRED BY FIELD CONDITIONS. I �+1CMUE 1rr1mL UVKA c�tu Ax THE CONTRACTOR SHALL SIZE THEM I SOLAR ARMY ON MAN HOUSE 5255 kw I I VA VW A.CEC-m,®sF ACCORDINGLY. (13)OCELL O.PEAK DUO MXMODULESG10f I05W PV MODULES I EwP4 SE AC CON9�NJi CONTRACTOR (1)STRING OF(13)MICRO-INVERTERS I I •z•.�.o ��� 7.) ALL WIRE TERMINATIONS SHALL BE 1 I AC DISCONNECT APPROPRIATELY LABELED AND READILY VISIBLE. ELEMENT ENERGY, LLC. �" ¢N °,.ERM 8.) MODULE GROUNDING CLIPS TO BE INSTALLED 7470 50UND AVE STRING #1 _ _ _ _ _ _ I I �.x 0A BETWEEN MODULE FRAME AND MODULE r ---------- _ _ _ _ _ _ _ --� °1`A= SUPPORT RAIL, PER THE GROUNDING CLIP MATTITUCK, NY 1 1952 1 '0" MANUFACTURER'S INSTRUCTION. LICENSE# G74G 1-111 -- --------- --- --- --- --- 9.) MODULE SUPPORT RAIL TO BE BONDED TO LICENSE# 52G89-ME CONTINUOUS COPPER G.E.C. VIA WEEB LUG I a,mrtCASE7VPrJL I r------ • ___ . - OR ILSCO GBL-4DBT LAY-IN LUG. I I 1 10. THE POLARITY OF THE GROUNDED CONDUCTORS PHA 08PLtA.�'-� I IS (positive/negative) .`�cOF NEwY °'s,cam"e.UL LM I i OR �Q 4gG A GAG �� I 10.) THE DC SIDE OF THE PV SYSTEM IS I L-----------------------V--------� i UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. I I I 1 11.) THE INSTALLATION COMPLIES WITH R327 ENERGY ,O unnr L"m n w I I STORAGE SYSTEMS. Z W ____ i 12.) CONDUIT AND CONDUCTORS SPECIFICATIONS AREa (? -� F I BASED ON MINIMUM CODE REQUIREMENTS AND ARE ' �O �03443 , 1 ram'® j I j NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY o llUTRM-PHA METER A �. 1 :,QEFl�1®1 , I ° 1 FIELD CONDITIONS. ' PwLg 2'D v ROFESSIONA ' 4. I `°° i ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN ' I I CONDUIT MINIMUM 7/8" ABOVE ROOF WITH PROPER I jam- i JUNCTION BOX AT EACH END. s,NL10®O°a' ° PeoJECT NAME I I I O I - I 1L I 1 Ly m. 00 OTHER LOADS «� u E I w U p 1 ---------------' coN���s j sn.¢�a.e.� N W Q L ---------------------� I a: i YIDA C) O - EL/ LLJ j ae� (N)200AAC I � w J z -----� amx- P LOAD PANEL CONNECTIONS A4lMtASi�EGOI O Q U_ uEO. o Q O L_________________________________ Q ( g m W SONNEN cA 0 U_ YM SERNOE PANEL n- L-___________________________________ 'ft°-' O *SYSTEM SPECIFICATIONS & NOTES* INErn= TOTAL SYSTEM SIZE: 15.39 kW MODULES: (38) QCELL, Q.PEAK DUO BLK ML-G10+ 405W PV MODULES j 1 1 j DG5TI1G tROumwG ELECTRODE SYS INVERTERS: (38) ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS I � JJ 'E' S EET NAME TOTAL (38) MODULES INSTALLED ON MAIN HOUSE SONNENCORE+20kWh 20kW11/240V 3 LINE D I A. WIRE & CONDUIT SCHEDUL.E _ MAX. STARTING TEMPERATURE CIRCUIT CONDUCTOR CONDUCTOR CONDUIT FILL CONDUCTOR GROUND CONDUIT AMBIENT ESTIMATED VOLTAGE ALLOWABLE CORRECTION ADJUSTED CURRENT CURRENT DRAWING SCALE IRCUIT I.D. CIRCUIT ORIGIN DESTINATION SIZE CONDUCTORS QUANTITY DERATE INSULATION GROUND SIZE QUANTITY CONDUIT SIZETYPE TYPE TEMP. DISTANCE DROP (7.) AMPACITY FACTOR CONDUCTOR APPLIED TO APPLIED TO PER POLE 310.15(B)(3) 310.15(B)(1 6)310.15(B)(1 6) AMPACITY CONDUCTORS CONDUCTORS kQFWAY �I �j 1 VMRD_- COMBINER 9 R BOX AWG #12 1 4 0.8 SE-2 PV-IRF AWG #8 1 BARE CU EMT 55'C 110 FT. 1.89 30 0.84 20.16 15.73 19.66 T.`� 2 COMBINER BOX AG AWG #8 1 3 1 THWN-2 AWG #8 1 THWN-2 CU PVC SCH 40 45'C 50 FT. 0.96 55 0.96 52.80 30.25 37.81 3 AC DISCONNECT P01 AWG #6 1 3 1 THWN-2 AWG #8 1 THWN-2 CU PVC SCH 40 45'C 30 FT. 0.04 75 0.96 72.00 30.25 37.81 5!1EET NUMBER 4 BATTERY AWG #8 1 3 1 THWN-2 AWG #8 1 THWN-2 CU PVC SCH 40 45'C 10 FT. 0.88 55 0.96 52.80 NA NA 5 BATTERY POI AWG #8 1 3 1 THWN-2 AWG #8 1 THWN-2 CU PVC SCH 40 45'C 10 FT. 0.14 55 0.96 52.80 15.73 19.66 PV-6 TAX MAP: 1000-075.00-OG.00-003.002 i Zoh6 Sign Document ID:2A768FFA-QLI7HKS6MXYKUBZPKLWFROHICTBBTTESWIFLOSWMLUY SERVICE METER O O DEEMENTDENERGY LBY: INSTALLATION NOTE REVIEW BY J.M.NABCEP CERTIFIE ® � SOLARN,,SYSTEM PHOTOVOLTAIC e • • ( I ) ALL LABEL 5HALL BE INSTALLED IN 051112.129 EQUIPPED WITH 4 !SOLAR BREAKER ,lSG0RilEG? ACCORDANCE WITH THE 20 17 NEC REVISIONS MPIDSHUTDOM ® O REQUIREMENTS. DE5CPJPTI0N DATE REV ' (2) ALL LOCATIONS ARE APPROXIMATE AND OPJGINAL 05_01-2024 �DONpTRELpCATETHlSS �.MAX SYSTEM VOLTAGE VDC REQUIRE FIELD VERIFICATION. SOLAR AC LOAD CENTER- OUTSIDE �� - !OMCURRM MMICE (3) LABELS, WARNING(5) AND MARKING O TURN RAPID SHUTDOWN SWITCH TO g ® SHALL BE IN ACCORDANCE WITH NEC THE'OFF POSITION TO SHUT DOWN '', 0 ---- ------_--._-- 1 10.2 1 (B). i PV SYSTEM AND REDUCE �—-- ----_ ` SHOCK HAZARD IN THE ARRAY '1 [_�A�C DISCONNECT rOWERMTMMssAERvM= AM5�® (4) THE MATERIAL USED FOR MARKING _-___-- Ff=THE FOLLOWINGSOURCES WUH °'�XNE°' LC=lE°"Mom MUST BE WEATHER RE515TANT, IN SOLAR AC LOAD CENTER- INSIDE COMPLIANCE WITH NEC 1 10.2 1 ENERGY,(B)(3). `ONNERR pVSRFA%ER I ELEMENT EGY, LLC. ARNI� M - -- wARA, (5) THE PV SYSTEM CIRCUIT CONDUCTORS 7470 SOUND AVE L+�WARNING �° SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 135 THIS EQUIPMENT FED BY MULTIPLE DUAL POWER SUPPLY LICENSE # G 74 G I-HI � RATING GpF�B SOURCES:UTILITY GRID e, COMPLIANCE WITH NEC G90.3 1 . LICENSE# 52G89-ME MAN SUPPLY OVERCURRENT AND PV SOLAR DEVX;F SHALL NOT EXCEED ELECTRIC SYSTEM AMFE"OF BUSBAR oF CONDUIT - INSIDE BUILDING _ _ �P�Qg0 AEc s0 W R �� aNING e I WARN G �WNAR '1'NG a THIS SERVICE METER -' Uj PHOTOVOLTAIC SYSTEM IS ALSO SERVED BY A Z W I ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM r COMBINER PANEL 9 � TERMINALS ON THE LINE AND - �O 103443 1 LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS A CONDUIT - OUTSIDE BUILDING ---w?HE°PENP°smDN ---------- -- '40 SgtOt�P� PR:JJFCT NAME W MWdWING0 LL- DUAL POWER SUPPLY W U I SOURCES:UTILITY GRID AND < n c PV SOLAR ELECTRIC SYSTEM' w Q Ln MAIN SERVICE PANEL - OUTSIDE 0 ACAUTtQNSOL4RCIRCUff g U J z O O O ACAUTION __ o Q L t SOLI ELECTRIC SYSTEM COT4iECTED W z N cn O MAIN SERVICE PANEL - INSIDE NMI - NIT -1OPERATING CURRENT AMPS PON/ER SOURCE OUTPUT CONNECTION SHEET NAME ® O DO NOT RELOCATE THIS OVERCURRENT DEVICE AC DISCONNECT/BREAKER DRAWING SCALE O0-z O (3G N .T.S. SHEET NUMBER PV-7 TAX MAP: )000-075.00-OG.00-003.002 Zoho Sign Document ID:2A768FFA-QLI7HKS6MXYKUBZPKLWFROHICTBBTTESWIFLOSWMLUY Town of Southold ,�� �� [, May 3rd, 2024 Building Department Town Hall Annex G E 54375 Main Road MAY 1 0 210N .L P.O. Box 1179 Southold, New York 11971-0959 Subject: Battery Energy Storage System and Roof-Mounted PV System at Flanagan Residence Located at 325 Wells Rd. Peconic, NY 11958 To Town of Southold: I hereby affirm and certify that, following comprehensive professional evaluations, the plans for the installation of both the Solar PV System and the Battery Energy Storage System (BESS) comply with the 2020 Residential Code of New York State, the 2020 Building Code of New York State, the 2020 Fire Code of New York State, the 2017 National Electric Code, ASCE 7-16, and other relevant industry standards and regulations. These certifications are provided in strict adherence to the governing regulations and standards applicable to such installations. For the Solar PV System, it is my professional opinion that the subject plans comply with the aforementioned codes and standards. The structural framing of the existing roof has been evaluated to support the additional loads from solar panels, with deflection and stresses within allowable limits for wind pressures and snow loads specified in the codes. The mounting locations and methods indicated in the plans are deemed adequate, and the existing building and roof framing are structurally sufficient to support the solar panels. Regarding the Battery Energy Storage System (BESS), the proposed plans have undergone thorough scrutiny and are confirmed to align with requisite codes and standards. Utilizing Lithium Iron Phosphate technology, the BESS adheres to UL9540A standards to prevent thermal runaway. The enclosure design meets fire-resistant requirements outlined in the NYS Building Code. In my professional opinion, derived from site inspections and detailed analyses, both the proposed Solar PV System and the BESS, including the enclosure system, demonstrate structural adequacy to withstand associated reactions. Please feel free to contact me if you have any questions or require further clarification. Sincerely, OF N E!V Y Gennaro Anthony Giustra. P.E. ,�P��go A of opt Great Eastern Services, Inc. PO Box 240 24 Harvey Rd ZN ^�� % Riverhead, NY 11901 �0 103443 Mobile: 631.235.0189 AROFEssl�NP� Email: jerrygiustra@gmail.com