Loading...
HomeMy WebLinkAbout49864-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49864 Date: 10/10/2023 Permission is hereby granted to: Zuckerman J Living Trt 1510 E Gillette Dr East Marion, NY 11939 To: construct additions and alterations (inclusive of Tesla charger in garage) to existing single-family dwelling as applied for. At premises located at: 1510 E Gillette Dr, East Marion SCTM # 473889 Sec/Block/Lot# 38.-3-25 Pursuant to application dated 9/20/2023 and approved by the Building Inspector. To expire on 4/10/2025. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $315.60 CO-ADDITION TO DWELLING $50.00 Total: $365.60 Buiq ung Inspector rr�txTOWN OF SOUTHOLD-BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 lett) :0/vwrw't�v.SCLitl oldt wriii ��v'. Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Buildingdnspector; SEP 2 0 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted: Where the Applicant is not the owner,an Building Department Owner's Authorization form(Page 2)shall be completed. Town of Southold Date: OWNER(S)OF PROPERTY: Name: JC)e Z.Ue ee(2-IMA-N SCTM#1000- Project Address: (SIO e% G(LLerr-m OVtU>C 5A4'T VV A10 t•0 N Phone#: I — L 4 — 4�5-b O l q Email: r'L l v3 w mai t cOM Mailing Address: (!(-p 6 , GIC,[.eT V(Zt VV CONTACT PERSON: Name: J DA-tJ C": "I •,. Mailing Address: P� 8 4 ct cS6eJ-V1:+0LD p1 l (q-7 Phone#: 63 t - SAA—4 2-41 Email: "fin &t0,r We.ry to rytat( DESIGN PROFESSIONAL INFORMATION: Name: LOU et-(-W A-(-Z-TZ, Mailing Address: �lQ� (Obfl s'�. c �� < < -7O8 Phone#: ��� L'- to (�8�o Email:--�Aerun nereln Q (YlatCOm CONTRACtOFC;,INFORMATION '' Name: Mailing Address:. Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Q-W QtJ EXIST-. Sao $ Will the lot be re- raded? ❑Yeslo Will excess fill be removed from premises? ❑Yes>NO i PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated:: Are there any covenants and restrictions with respect to this properly? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Coded APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance_of the To*n of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary Inspections.'False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): b A--J AAuthorized Agent ❑Owner Signature of Applicant: Date: 9 --2D-2 3 STATE OF NEW YORK) COUNTY OF`j'L J being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contract , Agent, rporate Officer, etc.) of said owner or owners, and is duly authorized to ri r have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of-Sr202 r Notary Public TRACE" . DWyEj,.j PROPERTY OWNER AUTHORIZATION NOTARy P BM,STATE NE '�"��,;,-,.. O ALIEB IN UFNO,01 FOLOUN-`y ()6900 (Where the applicant is not the owner) DSSIDN E B jUjqe,3fl, L.........., 0S _27-U Q4-6 F—M ......:: siding at _. �'� �r" � ILLA5T'� �� do hereby authorize Vl.//1��? Cf�Tyy�G 1 ­­to apply on my behalf to the Town of Southold Building Department for approval as described herein.. Owned Signature Date Print Owner's Name 2 TEST MOLE 4-11-00 e.>_= 1 -o 3 DARK lareav(N s a , SAMMY LOAM &I--- 11.1 Q BROWN L*AMY �^; Bn,r.t v W 9-17, _ PALE 9RowN FINE To COARSE V-L- SA.t4 rs _ ��� - �.�=y�.2 -Ems.8 73 •. } WATER IN PALE Rt7owwl yv N 2 -- ?s' CiR0l.1tJD WAIF R r Ftke To _ Ems- 3.-73 COARSE (NPT TC SCALE SCAN D '1jF- f w0 � 3w N �aT� al rQ _ U . 1p•• � E�� e� d1 %.s1-- N Fo4-' '-16E.7 - -� dr m J -� 8L. >� 0 1a r1 0 Z4 0 -3 o. 11' - N L �` d Z.o a .W 0 0 0 N 1 T � r F ' P t `i 1 S W 1 -t-►-1 t �J f f~ l R Nl i -r 4 ,-1 o OC PA tr=. 1 0 3 C o t --7 -7 G ter._ ` - P��Z'E� M.-�-i '`4•', 199 B �t t_1Qta: t"1�2 . 1�J I�=� -•'� t�l� r 2�0- .l.�r +.-n.cn►a.-a C3l-CaQ1..gab. S�T-7 r0t�.�T1'1 Svcus- 1000 - 38-03-25 1000 - 38-03-25 =4=>"MCP Q - 4cz), l=Ll��i.�•T1ati1S ht G�1 1 soathorized afterstion or addition to this survey is a violation,of section 72"of the New York State Education Is%. Copies of this survey atop set hearing the Laud%un•eyers inked or embossed seal is not considered to he a true valid copy. Distances shows from property lines to existing structures are for a specific purpose sod one and are not intended to;nide is the erection orfewes or other structures. Certification indicated hereon shah ran only to the person fur whom the survey is L�I IL�GC=p6j 1 kte 1 N.) prepared and as his behalf,to the Costpsay or Agencles listed hereon and to the assignees of the leading institution.Certifications are not transferable to additional iaetitotions or subsequent owners. ST ' t. !J 0 w_ C-0 NJ 45"x'. t �� `c, N 64 51 10 E 81 .51 ' - - - - - - - - - - - - - - - I I °� � • r-1cl• i � . I r 1 � r I N I • 18'-81" � 3 5'-Oi" � 2 4 I �-13'-04' 3' 2"1 I 1 INEW OLRUOORSHOWER- 61AS1'ERSf'ASr.••c,: m i I EXISTING ONE STORY RESIDENCE STOOP I a O r I ' j 1`1 •I J NEW STAIRS PAIL. ,•� I I �-/ / L_1__ I EXIST.STOOP y,.%',s' u� O W 1 Q DECKING NEW COMPOSITE .k,�:4:., I to ADD NEW VWri RAILS O EXIST.STEPS•-f�REMOVE ^ I 00 I E-- o I j W �.I .. ..I.••. EXISTING DRIVEWAY i L ) co.._.. ... .. _J uI N EXISTING STAIRS TO ' I CELLAR ENTRY R I I N V z I . I LJ I I I I , I I I I INE I I , I o I I I A 77006 I '�OFfSS10�P I NOTE: I PROPERTY LINE DIMENSIONS AND HOUSE PLACEMENT I TAKEN FROM SURVEY BY ELIZABETH MCKULKIN 2.2 3.2 000 LIC. # 050211 I I , -�- - - - - - - - - - - - - - - - - S 64 51 10 W 83.22I o .; z .: .L C* co ZUCKERMAN RESIDENCE t � q w z m _.x 1510 E. GILLETTE DRIVE EAST MARION � » 1000-38.-3-25 r� i TTTT i -T- " - - - -' -- - i 1- TTTT7 LINE OF STOOP ABOVE • ! ! ! I ! I f ! ! I I 1 ! ! LINE OF CANTILEVER ABOVE ! EXIST. EXIST. 2816 2816 ..v * ' i. 0 EXISTING CELLAR DOOR +6 O w N W TYPICAL INTERIOR PARTITION 2X @ 16" OC WALL UNHEATED < Lx 1/22" GYP. BD @ BOTH SIDES `° F- FINISHED STORAGE ROOM } « DROPPED CEILING O z PAINTED GYP. BD. WALLS W MANUFACTURED WOOD FLOORING O UNFINISHED UTILITY 27'-6" 1„ 2 _6. ,; co -'- - - - - - - - - - - -- - - - - - - - - -- - - -- -___ - ---=- - - - - - - - - - - - - N 8'-0" ----- UR TO 1S FLOOR E(IST NG ISTAIIRS NEW GAS FIRED ( 00 @TOP OF ISTIRS) ON DEMAND HOT WATER SYSTEM, GARAGE ABOVE UNFINISHED STORAGE o ,l f SLAB (j)- X00 s LINE OF CANTILEVER ABOVE f — — — — — - - — — — — — — — — — — — — — -- — FRONT PORCH ABOVE �— — '— — — — '— — — — — — — -- — — — — — -- — — -- — — -- — — — — — — � - -- -- - - - - � FLOOR PLAN - -- - - - - -- BASEMENT FINISHED STORAGE 1 /411 11-011 NE 1 k� s D z� 00 > ZUCKERMAN �SJREIDEE � r O D > 1 r-i z 1510 E. GILLETTE DRIVE EAST MARION .. .�..r ;. .� K. * 77006NJ 00 1 co START M o 0 = 1000-38.-3-25 permits I drafting expeditingpsswNa`' PRODUCT OVERVIEW This manual applies to Wall Connectors identified by part number 1457768-**-*. Product Specifications Voltage and Wiring Nominal 200-240 V AC single-phase Current Output Range 12 - 48 amps Terminal Blocks 12-4 AWG (3.5 - 25 mm2), copper only Supported Conduit Sizing % in (21 mm) default, 1 in (27 mm) optional Grounding Scheme TN/TT Frequency 50/60 Hz Cable Length 7.3 m (24 ft) Wall Connector Dimensions Height:13.6 in (345 mm) Width: 6.1 in (155 mm) Depth: 4.3 in (110 mm) Wire Box Bracket Dimensions Height: 9.8 in (250 mm) Width: 4.7 in (120 mm) Depth:2.0 in (50 mm) Weight(including wirebox) 10 ib. (4.5 kg) Operating Temperature -22-F to 122-F (-30°C to 50°C) Storage Temperature -40°F to 185°F (-40°C to 85°C) Enclosure Rating Type 3R Ventilation Not required Means of Disconnect External branch circuit breaker Ground Fault Circuit Interrupter Integrated, no additional required (CCID20) Wi-Fi 2.4 GHz, 802.11b/g/n Agency Approvals cULus - E351001 Transportation and storage: Ensure that Wall Connector is within storage temperature when moving, transporting, or storing. This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. Gen 3 Wall Connector Manual 5 ��.. PRODUCT OVERVIEW Circuit Breaker Rating / Maximum Output Power Output ° , For maximum power output, install a standard double pole 60 amp circuit breaker.Wall Connector includes integrated GFCI protection -do not install a GFCI circuit breaker. Wall Connector incorporates automatic load management, which allows the max output to be customized to an existing power supply. If the electrical supply is unable to support the 60 amp configuration, select a lower amperage configuration. Circult;breaker;,(am ,s f Power..output:>3t.24'60 0-wolts,'�k1N)""-": ' 48 11.5 so 40 . . 9.6 4032 7.6 30 24 - 5.7 20 16 3.8 15 12 2.8 NOTE: External disconnect switches are neither re aired nor recommended. NOTE: Circuit breaker.size is programmed during the commissioning -Procedure on page 28 for details, process. See Commissioning NOTE: Some Tesla vehicles May draw less current than the max output. Actual charging rate depends on Wall Connector output and onboard charger in the vehicle. Branch Circuit Conductors and Ground Wire • If installing for less than maximum power, refer to local electrical code to select correct conductors and ground wire size that are suitable for the chosen circuit breaker. • If installing for maximum power, use minimum 6 AWG, 90° C-rated copper wire for conductors. NOTE: Upsize conductors if necessary. • For sites with multiple Wall Connectors, each Wall Connector must have its own branch circuit with Ll, L2/N, and Ground, • COPPER WIRE TERMINATIONS ONLY for landing in Wall Connector wirebox terminals. Conductors can be stranded or solid. • Hardwire branch circuits to disconnects or circuit breakers. Do NOT install cord-and-plug type connections. • For outdoor installations, use watertight fittings when securing feeder wires to the wirebox. Gen 3 wail Connector Manual 6